INSTRUCTIONS GENERALES

image

Contents

1. With SWEEP TGEN AUTO the function of the rear panel TRIG SWEEP OUT socket changes automatically when the operating mode is changed between Sweep HOP and any other mode the two functions of this output are described in the Connections section When SWEEP TGEN SWEEP is set the TRIG SWEEP OUTput is always in the Sweep mode if sweep is operational or HOP mode if HOP is on when SWEEP TGEN TRIG the TRIG SWEEP OUTput always outputs the internal trigger generator signal Note that except when using the internal trigger generator in Trigger Gate FSK or AM modes this signal is not synchronised with the main generator Sweep Operation 4 3 1 General DDS operation gives the significant advantage over conventional function generators of phase continuous sweeps over very wide frequency ranges up to 10 1 However it must be remembered that the frequency is actually stepped not truly linearly swept and thought needs to be given as to what the instrument is actually doing when using extreme GX1010 Il 21 22 Il combinations of sweep time and frequency span see Frequency Stepping Resolution section Sweep mode is turned on and off with alternate presses of the SWEEP key the lamp beside the key lights when sweep mode is on The sweep parameters begin end and marker frequencies sweep direction law ramp time and source are all set from the sweep edit menu which is selected by pressing the blue EDIT key followed by the SWEEP key W
2. 1 Disconnect the instrument from all voltage sources 2 Remove the screws which retain the top cover and lift off the cover 3 Change the transformer connections as follows for 230V operation connect the live brown wire to pin 15 for 115V operation connect the live brown wire to pin 14 for 100V operation connect the live brown wire to pin 13 4 Refit the cover and the secure with the same screws 5 To comply with safety standard requirements the operating voltage marked on the rear panel must be changed to clearly show the new voltage setting 6 Change the fuse to one of the correct rating see below 230 V 115V 100V OV Calibration All parameters can be calibrated without opening the case i e the generator offers closed box calibration All adjustments are made digitally with calibration constants stored in EEPROM The calibration routine requires only a DVM and a frequency counter and takes no more than a few minutes GX1010 The crystal in the timebase is pre aged but a further ageing of up to 5ppm can occur in the first year Since the ageing rate decreases exponentially with time it is an advantage to recalibrate after the first 6 month s use Apart from this it is unlikely that any other parameters will need adjustment Calibration should be carried out only after the generator has been operating for at least an hour in normal ambient conditions 3 3 1 Equipment Required e 3 digit DVM with 0 25 D
3. 14H TAD Talk Address pour tout instrument 03H UNA Code de contr le Universal Unaddress 04H LNA Code de contr le Lock Non Addressable mode 18H UDC Universal Device Clear Avant qu une r ponse puisse tre lue par un instrument il doit tre adress sur mission par transmission du code de contr le Talk Address 14H TAD suivi d un seul caract re dont les 5 bits inf rieurs correspondent l adresse unique de l instrument requis de la m me mani re que pour le code de contr le d adresse de r ception ci dessus En mode adress sur mission l instrument transmet le message de r ponse disponible le cas ch ant puis sort de l tat adress sur mission La r ception d un des codes de contr le d interface suivants annulera le mode mission 12H LAD Listen Address pour tout instrument 14H TAD Talk Address suivi d une adresse non utilis e par cet instrument 03H UNA Code de contr le Universal Unaddress 04H LNA Code de contr le Lock Non Addressable mode 18H UDC Universal Device Clear Le mode mission sera galement annul lorsque l instrument a fini d envoyer un message de r ponse ou qu il n a rien dire Le code d interface OAH LF est le Universal Command and response Terminator UCT ce code doit tre le dernier code transmis pour toutes les commandes et ce sera le dernier code transmis dans toutes les r ponses On peut utiliser le code d interface ODH CR selon les besoins pour faciliter la mis
4. Il peut tre soumis de temps autre a des temp ratures comprises entre 5 C et 10 C sans que sa s curit en soit r duite 1 1 2 Pendant l utilisation Toute utilisation de cet instrument de mani re non sp cifi e dans ce manuel risque de r duire la protection de s curit conf r e Ne pas utiliser l instrument l ext rieur des tensions d alimentation nominales ou des conditions ambiantes recommand es En particulier toute humidit excessive risque de r duire la s curit AVERTISSEMENT CET APPAREIL DOIT ETRE RELIE A LA TERRE Toute interruption du conducteur de masse secteur l int rieur ou l ext rieur de l instrument entra nera des dangers pour l utilisateur Il est absolument interdit de provoquer une interruption dessein Il ne faut pas annuler la protection pr vue en utilisant un cordon d extension sans conducteur de protection Lorsque l instrument est reli son alimentation il est possible que l ouverture du couvercle ou la d pose de pi ces l exception de ceux auxquels on peut acc der manuellement mette d couvert des pi ces sous tension II faut d brancher l appareil de toute source de tension avant de l ouvrir pour effectuer des r glages ou des travaux de remplacement d entretien ou de r parations S il est vident que l instrument est d fectueux qu il a t soumis a des d g ts m caniques une humidit excessive ou une corrosion chimique la protection de s curit
5. SWPLAW lt cpd gt SWPMKRFRQ lt nrf gt SWPMKRPER lt nrf gt SWPMODE lt cpd gt SWPSRC lt cpd gt SWPTIME lt nrf gt SWPTRGOUT lt cpd gt SYMM lt nrf gt TGEN lt nrf gt TGEN lt nrf gt TGEN lt nrf gt TRIAN TRIG lt cpd gt TRIGSRC lt cpd gt ZOUT lt nrf gt Set phase to lt nrf gt degrees Set positive pulse function Set positive ramp function Define a new Arbitrary function Data for one step in the sequence Define a new staircase function Set sine function Set squarewave generation mode to lt AUTO gt lt HF gt or lt LF gt Set square function Set staircase function Set staircase function Set sweep mode to lt ON gt or lt OFF gt Set sweep begin frequency to lt nrf gt Hz Set sweep begin period to lt nrf gt seconds Set sweep end frequency to lt nrf gt Hz Set sweep end period to lt nrf gt seconds Set sweep law to lt LOG gt or lt LIN gt Set sweep marker frequency to lt nrf gt Hz Set sweep marker period to lt nrf gt seconds Set sweep mode to lt BTOE gt begin to end or lt ETOB gt end to begin Set sweep source to lt CONT gt continuous lt EXT gt external or lt MAN gt manual Set sweep time to lt nrf gt seconds Set sweep tgen output bnc mode to lt AUTO gt lt SWEEP gt or lt TGEN gt Set symmetry to lt nrf gt Set trigger generator period to lt nrf gt seconds Set trigger generator period to lt nrf gt seconds Set trigger generator p
6. au point par exemple 40 60 de sym trie 40 Les points 0 et 180 sont chelonn s math matiquement afin de tenir dans 40 du cycle et les points 180 360 sont interpol s pour tenir dans 60 du cycle La phase start stop fonctionne toujours avec les vrais r glages de phase mais ceux ci ne sont pas n cessairement l endroit attendu de la forme du signal en particulier dans le cas des formes des signaux tr s complexes GX 1010 7 SPECIFICATIONS TECHNIQUES 7 1 G n ralit s Les sp cifications s appliquent entre 18 C et 28 C apr s une heure de chauffe une sortie maximum de 50 Q Affichage entr e des donn es R glages stock s 7 2 Caract ristiques 20 caract res x 4 lignes alphanum riques LCD S lection par clavier du mode signal etc entr e directe des valeurs par clavier num rique ou commutateur rotatif Jusqu 9 r glages complets peuvent tre stock s et rappel s dans la m moire 7 2 1 Performances fonctionnelles 7 2 1 1 FR QUENCE Gamme R solution Pr cision Stabilit de temp rature 7 2 1 2 SYMETRIE Gamme R solution 7 2 1 3 FORMES DE SIGNAUX 0 1 mHz 10 MHZ Toutes les formes de signal sont disponibles jusqu 10 Mhz Cependant la puret des signaux triangle rampe et carr multi niveaux n est pas sp cifi e au dessus des fr quences indiqu es dans la section FORMES DE SIGNAUX En mode arbitraire tous les points du signal sont s
7. pr vue risque d avoir t r duite et dans ce cas il ne faut plus utiliser l appareil mais le renvoyer en vue de v rifications et de r parations S assurer de bien utiliser uniquement des fusibles d intensit nominale requise et de type sp cifi en vue de remplacement II est interdit d utiliser des fusibles bricol s ou de court circuiter les porte fusibles L instrument utilise une pile bouton au lithium pour la m moire non volatile sa dur e de vie est environ 5 ans Pour son remplacement utilis une pile du m me type i e 3V Li MnO type 2032 Les piles us es doivent tre jet es en accord avec les lois locales ne pas couper br ler exposer des temp ratures au del de 60 C ou essayer de la recharger Ne pas mouiller l instrument pendant un nettoyage Utilisez un chiffon doux et sec pour l afficheur LCD Les symboles suivants sont utilis s sur l instrument et dans le manuel GX 1010 EN 1 3 1 1 3 Symboles Attention Se r f rer la notice un fonctionnement incorrect peut endommager l appareil ER Borne de masse 1 1 4 Consignes Avant toute ouverture de l appareil le d connecter imp rativement de l alimentation r seau et des circuits de mesure Il faut viter dans la mesure du possible d effectuer des r glages des travaux d entretien ou de r paration lorsque l instrument ouvert est sous tension mais si c est toutefois absolument indispensable seul un technicien exp riment
8. DBM nrf gt DCOFFS lt nrf gt EER EMFPP lt nrf gt EMFRMS lt nrf gt FILTER lt cpd gt FREQ lt nrf gt FSK lt cpd gt FSKFRQA lt nrf gt FSKFRQB lt nrf gt FSKPERA lt nrf gt FSKPERB lt nrf gt FSKSRC lt cpd gt GATE lt cpd gt GATESRC lt cpd gt HOP lt cpd gt lt nrf gt LRN lt character data gt NEGPUL NEGRAMP NOISE lt cpd gt OUTPUT lt cpd gt PDPP lt nrf gt PDRMS lt nrf gt PER lt nrf gt PHASE lt nrf gt Executes a trigger which will have the same effect as pressing the MAN SYNC key The generator has no self test capability and the response is always O lt rmt gt Wait for operation complete true Abort on unsuccessful phase locking operation Set AM mode to lt ON gt or lt OFF gt Set internal AM depth to lt nrf gt AM source to lt EXT gt or lt TGEN gt Set internal AM wave to lt SINE gt or lt SQUARE gt Set arbitrary function Set arbitrary function Query the selected arbitrary waveform Recall arbitrary waveform from store lt nrf gt Save arbitrary waveform to store lt nrf gt with name lt character data gt Set AUX output mode to lt AUTO gt lt HF gt or lt LF gt Set burst count to lt nrf gt cycles Sound one beep Set beep mode to lt ON gt lt OFF gt lt WARN gt or lt ERROR gt Set clock bnc mode to lt OUTPUT gt lt INPUT gt or lt SLAVE gt phase lock Set output level to lt nrf gt pd dBm Set dc offset to lt nrf gt Volts Q
9. FSK Frequency Shift Keying mode permits fast phase continuous switching between two frequencies All other parameters of the waveform amplitude offset symmetry remain the same as the frequency is switched for switching between waveforms where all parameters can change refer to HOP FSK can be controlled by either the internal trigger generator an external trigger input by the front panel MAN SYNC key or by remote control FSK mode is turned on and off with alternate presses of the FSK key the lamp beside the key lights when FSK mode is on The FSK mode parameters frequencies trigger source and internal trigger generator are all set from the FSK edit menu which is selected by GX1010 4 7 pressing the blue EDIT key followed by the FSK key When FSK edit is selected the lamp beside the FSK flashes to show edit mode regardless of whether FSK mode is currently selected to be on or off FREQ A 10 00000kHz FREQ B 10 00000MHz SOURCE EXT TGEN 1 00ms 1 000kHz 4 6 1 Frequency Setting The two frequencies FREQ A and FREQ B between which the waveform is switched are set in exactly the same way as the frequency on the Main menu in fact FREQ A is the main generator frequency in non FSK mode and changing FREQ A on the FSK edit menu will also change the frequency shown on the Main menu 4 6 2 Trigger Source With the edit cursor in the SOURCE field of the FSK edit menu the DIGIT keys or rotary control can be used to select
10. Linearity error 5mV to 20V p p open circuit o p lt 0 3 THD to 500kHz lt 50dBc to 1MHz lt 35dBc to 10MHz typically lt 55dBc to 10MHz 5mV to 20V p p open circuit o p lt 25ns 5mV to 20V p p open circuit o p lt 0 5 to 30 kHz GX1010 e Positive and Negative Ramp Output level 5mV to 20V p p open circuit o p Linearity error lt 0 5 to 30 kHz e Positive and Negative Pulse Output level 2 5mV to 10V p p open circuit o p Rise and Fall Times lt 25ns e Multi Level Squarewave Up to 16 steps available per cycle each step selectable for amplitude 10 bit resolution and duration 1 to 1024 samples Allows generation of 3 level squarewave staircase multiplexed LCD driver signals etc Frequency Range All waveform points can be continuously output up to approximately 27kHz above which sampling will introduce a 1 clock edge uncertainty 1 clock 36ns Output level 5mV to 20V p p open circuit o p Rise and Fall Times lt 25ns e Arbitrary A number of frequently required waveforms are pre programmed in ROM Alternatively waveforms can be downloaded via the generator s RS232 or GPIB interfaces and stored in non volatile RAM Frequency range All waveform points can be continuously output up to approximately 27 kHz above which they are sampled Output level 5mV to 20V p p open circuit o p Number of samples 1024 Sample levels 1024 10 bits es HOP Up to 16 different waveforms can be output
11. The bits in the PPE command are shown below Parallel poll enable bit4 0 bit position of the response Example To return the RQS bit bit 6 of the Status Byte Register as a 1 when true and a 0 when false in bit position 1 in response to a parallel poll operation send the following commands PRE 64 lt pmt gt then PPC followed by 69h PPE The parallel poll response from the generator will then be 00h if RQS is O and Oth if RQS is 1 GX1010 Il 41 42 Il During parallel poll response the DIO interface lines are resistively terminated passive termination This allows multiple devices to share the same response bit position in either wired AND or wired OR configuration see IEEE 488 1 for more information 5 1 4 Power on Settings The following instrument status values are set at power on Status Byte Register 0 dj Service Request Enable Register 0 Standard Event Status Register 128 pon bit set 2 Standard Event Status Enable Register 0 Execution Error Register 0 Query Error Register D S Parallel Poll Enable Register 0 Registers marked thus are specific to the GPIB section of theinstrument and are of limited use in an ARC environment The instrument will be in local state with the keyboard active The instrument parameters at power on are determined by the setting of the POWER UP field on the SYStem menu see System Menu section If POWER UP POWER DOWN or POWER UP RECALL nn has been set and a de
12. form entering a number followed by the dBm key will cause the number to be entered as dBm Similarly with dBm as the selected parameter form entering a number followed by V or mV will cause the number to be entered as PD Vrms OdBm is 1mW into the specified impedance low signal levels are specified by using the key to enter negative dBm See also the last paragraph of this section for the use of the key for output inversion Moving the edit cursor to the numeric field permits the set value to be varied by the rotary control in steps determined by the cursor position within the field The FIELD keys move the cursor to the field and the DIGIT keys move it within the field this is explained more fully in the Principles of Editing section Moving the edit cursor to the units field permits the numeric value to be changed in decade steps by the DIGIT keys or rotary control the decimal point will move and or the units will change as appropriate Further increments are inhibited if the next decade step would take the value above the maximum level or below the minimum level Decade stepping with the DIGIT keys or rotary control is also inhibited when the level is displayed in dBm Wherever the cursor is positioned on the second line of the display alternate presses of the key will invert the MAIN OUT output if DC OFFSET is non zero the signal is inverted about the offset The one exception to this is if the output level is specified in dBm
13. rique lt nr1 gt Provoque un d clenchement ayant le m me effet que la pression de la touche MAN SYNC Le g n rateur n a pas de capacit d essais automatique et la r ponse est toujours O lt rmt gt Attend que l op ration soit ex cut e Avorte si une op ration de v rouillage de phase ne fonctionne pas R gle le mode AM sur lt ON gt ou lt OFF gt R gle la profondeur de modulation AM a lt nrf gt R gle la source AM sur lt EXT gt ou lt TGEN gt R gle la vague interne AM sur lt SINE gt ou lt SQUARE gt R gle la fonction arbitraire Effectue une requ te sur la forme de signal arbitraire s lectionn e Rappelle les num ros de stockage des formes de signaux arbitraires lt nrf gt Sauvegarde les formes de signal arbitraire sous le num ro de stockage lt nrf gt avec le nom lt chaine de caract res gt R gle le mode de sortie AUX sur lt AUTO gt lt HF gt ou lt LF gt Fixe la salve lt nrf gt cycles Envoie un bip R gle le mode bip lt ERROR gt Regle le mode d horloge bnc sur lt OUTPUT gt lt INPUT gt ou lt SLAVE gt v rouillage de phase R gle le niveau de sortie a lt nrf gt dBm R gle le d calage DC a lt nrf gt Volts Effectue une requ te puis efface le registre des num ros d erreurs d x cution R gle le niveau de sortie nrf V cr te cr te R gle le niveau de sortie lt nrf gt Vrms Fixe le mode filtre sur lt AUTO gt lt ON gt
14. s en m me temps qu un nom de 16 caract res dans la RAM permanente ces signaux occupent les m moires 01 05 incluses Les m moires 06 et au del contiennent plusieurs signaux arbitraires fr quemment utilis s enregistr s dans la ROM ils peuvent tre chang s et il est possible d en rajouter de temps en temps selon les demandes de l utilisateur Chaque signal arbitraire est enregistr sous 1024 points avec une valeur variant entre 512 et 511 c est dire avec une r solution verticale 10 bits 512 et 511 correspondant aux cr tes 10V et 10V respectivement avec une amplitude du menu Main r gl e au maximum Mais le signal actuel restitu partir du g n rateur peut avoir son amplitude d calage et sym trie ajust s comme si c tait un signal basique sinusoidal carr etc Les signaux arbitraires rappel s sont s lectionn s en appuyant sur la touche ARB la DEL cot de la touche ARB s allume et prouve que le mode arbitraire a t s lectionn Le menu edit ARB est utilis pour changer le signal arbitraire rappel pour enregistrer les nouveaux signaux dans la RAM permanente et pour les nommer On peut acc der aux signaux arbitraires en appuyant sur la touche bleue EDIT suivie de ARB Quand ARB edit est s lectionn la DEL situ e cot de la touche ARB clignote afin de montrer que le mode est s lectionn sans prendre en compte si le mode ARB est actif ou non RECALL ARB NO 14 SINX X CONFIRM
15. s allumage de l instrument Ceci activera tous les instruments reli s au bus ARC pour qu ils r pondent tous les codes de contr le d interface Transmettre le code de contr le Lock Non Addressable mode qui d sactive le mode adressable jusqu extinction de l instrument pour retourner en Non Addressable mode Avant qu une commande soit transmise un instrument l appareil doit tre adress sur r ception par transmission du code de contr le Listen Address 12H LAD suivi d un seul caract re dont les 5 bits inf rieurs correspondent l adresse unique de l instrument requis par exemple les codes A Z ou a z donnent les adresses 1 26 incluses alors que est l adresse z ro etc En mode adress sur r ception l instrument peut lire et r agir toutes les commandes transmises jusqu ce que le mode r ception soit annul Par suite de la nature asynchrone de l interface le contr leur doit tre inform qu un instrument a accept la s quence d adresse de r ception et qu il est pr t recevoir des commandes Le contr leur attend donc le code 06H ACK avant de transmettre de commandes L instrument adress donne cette ACK Le contr leur doit retourner z ro puis recommencer l op ration si aucun code ACK n est re u dans les 5 secondes La r ception d un des codes de contr le d interface suivants annulera le mode r ception GX 1010 12H LAD Listen Address suivi d une adresse non utilis e par cet instrument
16. since low signals are specified in dBm the sign is interpreted as part of a new output level entry and not as a command to invert the signal The output level must be shown as an EMF or PD value for the key to operate as a signal invert key If an amplitude change is made which involves switching the attenuator the output is switched off for 45ms whilst the change is made to prevent any transients appearing at the output 4 2 1 3 Output Impedance The impedance of the MAIN OUT output is selected in the last field of the second line Move the edit cursor to this field and use the DIGIT keys or rotary control to toggle between 50Q and 600Q The output level is unchanged but the displayed value in dBm will change because the OdBm reference level 1mW into the specified impedance changes with the impedance 4 2 1 4 DC Offset The DC Offset is set on the third line of the Main menu With the cursor anywhere in the third line the DC offset can be changed directly from the keyboard by entering the number and appropriate units e g 100mV can be set by entering 1 0 0 mV or 1 V etc If the cursor is not already in the third line of the display it is first necessary to press the DC OFFSET key to position the cursor before making the number and unit entry Note that GX1010 Il 15 16 Il unlike the FREQ or EMF parameter fields the cursor does not move into the DC OFFSET name because it has no alternative With the edit cur
17. 100Hz i e the 1kHz increment would be lost If however the starting setting had been FREQ 1 000000 MHz i e a 100 Hz increment the display would have autoranged at 1kHz to FREQ 900 0000 Hz and could then be decremented further right down to FREQ 000 0000 Hz without losing the 100 Hz increment Turning the control quickly will step numeric values in multiple increments GX1010 Il 11 4 1 6 Front Panel Connections 4 1 6 1 MAIN OUT This is the 50Q output from the main generator It will provide up to 20V peak to peak e m f which will yield 10V peak to peak into a matched 50Q load It can tolerate a short circuit for 60 seconds A Do not apply external voltages to this output 4 1 6 2 AUX OUT This is a TTL CMOS level output synchronous with MAIN OUT Symmetry is the same as that set for the main output but the phase relationship between MAIN OUT and AUX OUT is determined by the PHASE setting specified on the TRIGger menu AUX OUT logic levels are nominally OV and 5V from typically 500 AUX OUT will withstand a short circuit A Do not apply external voltages to this output 4 1 6 3 EXT TRIG This is the external trigger input for Trigger Gate Sweep FSK and HOP operating modes It is also the input used to synchronise the generator as a slave to another which is the master A Do not apply external voltages exceeding 10 V A A 12 Il 4 1 7 Rear Panel Connections 4 1 7 1 CLOCK IN OUT
18. 4 PERIODE TGEN gt 6 4 3 Impulsions avec Overshoot Les fronts et les pics d overshoot sont des signaux sinusoidaux Le taux de Surmodulation d pend de l angle de phase de d part qui varie de 89 30 L amplitude du g n rateur principal d termine l amplitude des pics l amplitude des portions plates d pend de la PHASE Pour poursuivre les exemples pr c dents R glez FREQ 2 0 kHz Appuyez sur EDIT TRIG afin de s lectionner le menu Trigger D clenchement D placez le curseur edit vers le champ PHASE et utilisez le contr le rotatif afin d ajuster la phase qui fera varier l amplitude de la portion plate cr ant ainsi une Surmodulation variable GX 1010 EMF PER PER PRINC PRINC gt x sym d gt x SYM 4 PERIODE TGEN kd PERIODE TGEN gt 6 5 Operations DDS et autres Consid rations de formes de signaux Cette section donne de plus amples informations sur les op rations DDS et permet de comprendre les avantages ainsi que les limites de la g n ration des formes des signaux DDS 6 5 1 Op rations DDS i i Filter ADRESSE Un cycle complet des formes de signaux s lectionn es est enregistr dans la RAM avec 1024 valeurs d amplitude 10 bit L adresse RAM tant incr ment e les valeurs des signaux sont sorties s quentiellement vers un Convertisseur Convertisseur Num rique Analogique DAC qui reconstruit le signal comme une s rie de niveaux de t
19. Byte Register 0 KR Service Request Enable Register 0 Standard Event Status Register 128 pon bit set id Standard Event Status Enable Register 0 Execution Error Register Query Error Register 0 i Parallel Poll Enable Register 0 Les registres marqu s de cette mani re sont sp cifiques la section GPIB de l instrument et leur utilisation est limit e dans un environnement ARC L instrument se trouve l tat local avec le clavier actif GX 1010 43 44 Les param tres de l instrument quand l instrument est allum sont d termin s par le r glage du champ POWER UP sur le menu SYSt me Se reporter a la section Mode d op ration Si POWER UP POWER DOWN ou POWER UP RECALL nn a t fix et qu un tat d fini est demand par le contr leur au d marrage alors la commande RST doit tre utilis e pour charger les valeurs par d faut du syst me Si pour une raison quelconque une erreur est d tect e la mise en route dans la m moire vive r manente un avertissement est indiqu et tous les r glages retournent leur valeur par d faut comme dans le cas d une commande RST 5 1 5 Registres d tat Cette section d crit le mod le d tat complet de l instrument Il faut noter que certains registres sont sp cifiques la section GPIB de l instrument et qu ils sont d utilisation limit e dans un environnement ARC 5 1 5 1 Etat d venement standard et registres d activation d tat d v nement stand
20. CAL 04 DC Offset ve full scale Check for 10V 20mV CAL 05 Multiplier zero offset Adjust for minimum CAL Op Waveform offset Note reading DCV CAL 07 Waveform offset Adjust for CAL 06 reading 10mV CAL08 Waveform DC offset Adjust for OV 5mV CAL 09 Waveform full scale Adjust for 10V 10mV CAL 10 Squarewave full scale Adjust for 10V 10mV CAL 11 20dB attenuator Adjust for 1V 1mV CAL 12 40dB attenuator Adjust for 0 1V 0 1mV CAL 13 12dB intermediate attenuator Adjust for 1 768V AC 5mV CAL 14 200B intermediate attenuator Adjust for 0 707V AC 1mV CAL 15 AM squarewave zero Adjust for minimum output CAL 16 AM squarewave full scale Adjust for 10V 10mV CAL 17 AM sinewave full scale Adjust for 3 54 VAC 10mV CAL 18 HF squarewave symmetry 50 Adjust for 50us 0 1us CAL 19 HE squarewave symmetry 75 Adjust for 75us 0 1us CAL 20 Clock calibrate Adjust for 10 00000MHz at MAIN OUT GX1010 or 27 48779MHz at rear panel CLOCK IN OUT Adjust to 1ppm Il 7 3 4 ee 8 Il Press CONFIRM twice to store new values and exit calibration mode Service Ensure that the correct mains fuse is fitted for the set operating voltage The correct mains fuse types are for 230V operation 250 mA T 250 V HRC for 100V or 115V operation 500 mA T 250 V HRC To replace the fuse disconnect the mains lead from the inlet socket and release the fuse drawer below the socket pins by depressing both clips together
21. EMF cannot be exceeded and clipping will occur if modulation attempts to drive the output beyond this limit The maximum generator output setting at which correct operation is maintained reduces from 20Vpp EMF to 10Vpp EMF as the modulation is increased from 0 to 100 4 5 1 3 Modulation Waveform The default modulation waveform is squarewave because this permits the full frequency range of the internal trigger generator to be used Alternatively a fixed 1kHz sinewave can be selected by moving the edit cursor to the INT MOD field in the last line of the display the DIGIT keys or rotary control can be used to toggle the setting between SQUARE at the frequency set on the internal trigger generator and SINE Note that selecting SINE forces the TGEN field to display 1 00ms 1 000kHz but the user setting is not lost and if INT MOD SQUARE is reselected the TGEN setting returns to its original value 4 5 2 VCA External With the cursor in the SOURCE field of the AM edit menu set the source to EXT VCA Connect the modulating signal to the rear panel VCA IN socket nominal 6kQ input impedance a positive voltage increases the generator output and a negative voltage decreases the output Note that as with internal AM clipping will occur if the combination of generator setting and VCA signal attempts to drive the output above 20Vpp EMF External AM is achieved by setting the generator to the required output level and applying the modulation signa
22. EXT ims 0 EXT ims 10kHz 10MHz EXT ims EXT VCA ims 30 Carr Signal carr sym trique a trois niveaux amplitude maximum e Param tres ARB Formes de signal par d faut du stockage 14 sinx x par exemple e Param tres de balayage Fr quence de d but Fr quence de fin Fr quence de marquage Mode Loi Temps de rampe Source Trig e Bruit Sans bruit GX 1010 100kHz 10MHz 5MHz D but a fin Log 50ms Continu 71 e Param tres Hop Hop Off Les param tres ne sont pas concern s par Recall 0 ou RST except pour le dernier chelon fix a 01 72 GX 1010 A Adresse 38 ARC 39 40 41 45 Arr t fr quence 21 Assemblage 6 AUX 62 AUX OUT 10 12 18 21 37 B Balayage 22 48 65 Bande limit e 58 Baud 38 Bruit 5 32 64 C Calibration 6 7 CEM 67 CLOCK 10 12 CLOCK IN OUT 36 66 CLOCK OUT 12 Commandes distance 47 Commandes d tat 50 Commandes de Syst mes 50 Compteur de Salve 26 CONFIRM 10 Consignes 2 Contr le rotatif 11 35 p DC OFFSET 15 33 DDS 4 9 59 D ballage 2 D clenchement 64 D clenchement externe 25 D clenchement interne 24 D clenchement par salve 5 DIGIT 10 11 Dur e 33 Echelon 32 EDIT 10 EMF PD 33 Escalier 30 49 ESCAPE 10 EXT TRIG 12 24 25 36 66 F FIELD 10 11 GX 1010 INDEX Filtre 20 Fonctions de base 14 47 Forme du signal de Modulation 28 Formes
23. EXTernal MAN REMOTE or internal Trigger GENerator as the trigger source which controls the frequency shifting With the source set to EXTernal the frequency is switched at each rising edge of the signal applied to the EXT TRIG input The minimum pulse width that can be used with the EXT TRIG input is 50ns and the maximum repetition rate is 1MHz With the source set to MAN REMOTE the frequency is switched with each press of the front panel MAN SYNC key or by the appropriate command via the RS232 or GPIB interfaces With the source set to TGEN the frequency is switched at each rising edge of the internal trigger generator the trigger generator produces a squarewave with a period that can be set from 0 02ms 50kHz and 200s 005Hz Period entries that cannot be exactly set are accepted and rounded up to the nearest available value e g 109ms is rounded to 12ms The generator output is available as a TTL level signal at the rear panel TRIG SWEEP OUT socket Setting the frequency of the internal trigger generator is fully described in the Trigger Source section of TRIGGERED BURST AND GATE Because the internal trigger generator can be used by the trigger gate FSK and AM functions and can be set on their respective edit menus an information field is displayed in brackets beside TGEN when this is selected on the source This field will show FREE when TGEN is not used elsewhere or any of the letters G F A T to indicate that the genera
24. OUTPUT AUTO la g n ration d un signal carr par sortie auxiliaire se commute automatiquement a 30 kHz de la g n ration DDS un signal d riv d un comparateur pilot par un signal sinus DDS les avantages de cette approche sont les m mes que ceux mentionn s pr c demment dans la section g n ration de signal carr Cependant comme il est dit dans la section Phase de sortie auxiliaire le mode de g n ration haute fr quence pr sente le d savantage qu une diff rence de phase ne peut plus tre r gl e entre AUX OUT et MAIN OUT La commutation automatique a 30kHz peut donc tre annul e en r glant AUX OUTPUT LOW FREQ pour le maintenir en mode DDS ou AUX OUTPUT HIGH FREQ pour le bloquer en mode fr quence haute Avec AUX OUTPUT AUTO il ny a pas de changement automatique de mode si les signaux rampe escalier ou arbitraire sont choisies Le mode haute fr quence peut cependant tre forc en r glant AUX OUTPUT HIGH FREQ Notez qu il y a une interaction de second ordre entre les r glages g n ration de signal carr Filtre et sortie auxiliaire qui demandent un l ger temps avant les changements des valeurs d faut Par exemple si les options SQWAVE GEN et AUX OUTPUT sont r gl es sur AUTO mais FILTER est d sactiv les fronts des signaux carr s MAIN OUT et AUX OUT pr senteront des jitter a haute fr quence car le signal sinus pilotant le comparateur partir duquel les deux sign
25. Options iii 20 4 3 SWEEP Opera it cdi 21 AO A A a 21 4 3 2 Connections for Sweep Operation iii 22 4 3 3 Setting Sweep Span and Markers nennen nnn 22 4 3 4 Setting Sweep Mode Ramp Time and Source cccccconcnocccccncnonnnannncnnnnnanannnncccnnnnnnnnn nano 23 4 3 5 Frequency Stepping Resolution ss 24 4 4 Triggered Burst and KEE 24 4 4 1 Internal Trigger Generator ie 24 44 2 External Trigger Input eee seats ne a 25 4 4 3 Trgger d Burst tienne dentiste a oia 25 AA A Gated MOOG EES 26 4 5 Gmpltoede Mogduleton ee eeerEukeue ege EA ASSEN canela 27 4 5 1 Amplitude Modulation Internal sacs coment etes ann miel 27 45 2 VGA EXGM EE 28 DE E 28 4 6 1 Frequency SINO viii nine EE EE 29 46 2 Trigger SUr E a a a a a 29 EE ENEE 29 E 29 4 7 2 AMWAY EE 30 BT SO E E 31 AB HOP eebe 32 4 8 1 Setting Each Waveform Step se 32 4 8 2 Defining the Sequence and Timing ENNEN 33 4 8 3 Running the S QUENCES ee las 33 4 8 4 Timing GOnsiderationss ios aba 33 4 8 5 Saving HOP Settings ci en nn ed Tee dee tn pis 34 4 9 Syst m Operations sscceecedeceesccssgeestedadeeeranstaeneededece ia 34 4 9 1 Storing and Recalling Setups 28 eee danses cans Gad ts deoulene dires 34 EE Le EE 34 4 10 Synchronising Generators isi set ee acs eas tnt ele taire tee date 35 4 10 1 SyNChronising Principles msn ds 35 4 10 2 Con
26. TO EXECUTE 4 7 2 1 Rappeler les signaux Arbitraires Le menu ARB par d faut est montr ci dessus Avec le curseur dans le champ de num ro de stockage chaque m moire peut tre chelonn e grace la molette ou une entr e clavier directe Chaque signal stock dans la ROM a un nom de r f rence dans la deuxi me ligne de l affichage par exemple sinx x les signaux d finis par l utilisateur dans la RAM permanente se verront attribu des noms par l utilisateur pendant la proc dure de stockage se reporter la section suivante Pour rappeler un signal particulier s lectionnez le num ro appropri puis appuyez sur CONFIRM Une fois le signal rappel dans la m moire de signal elle peut tre s lectionn e en appuyant sur la touche ARB 4 7 2 2 Enregistrer les Signaux Arbitraires Les signaux d finis par l utilisateur peuvent tre install es dans la RAM permanente via l interface RS232 ou GPIB pour plus de d tails voir la section commande Distance GX 1010 31 4 8 32 Les signaux arbitraires cr s partir du panneau avant les signaux escaliers peuvent tre sauvegard es dans la RAM permanente grace au menu ARB Avec le curseur dans le premier champ du menu des pressions sur les touches DIGIT permuteront le champ de RECALL STORE STORE ARB NO O1 CONFIRM TO EXECUTE Appuyer sur CONFIRM change le menu afin de permettre de rentrer le nom du signal Tourner le contr le rotatif permet
27. ajustable en interne Gamme de fonctionnement 14 nominal 30VA max Installation cat gorie Il Fusible les r f rences fusibles sont pour un fonctionnement de 230 V 250mA T 250 HPC de 100V ou de 115 V 500mA T 250 HPC Environnement 7 3 1 Temp ratures Temp rature de fonctionnement 5 C 40 C Temp rature de stockage 20 C 60 C Humidit relative 20 80 HR 7 3 2 CEM Ce g n rateur de fonctions a t con u conforme aux normes CEM en vigueur et sa compatibilit a t test e conform ment aux standards suivants CEI 1326 1 e Emissions Rayonn e et par conduction CEI 1326 1 classe A GX 1010 67 7 4 7 5 68 e Immunit Les m thodes de test suivantes ont t utilis es a CEI 1000 4 2 d charge lectrostatique b CEI 1000 4 3 Champ RF c CEI 1000 4 4 Transitoire rapide d CEI 1000 4 11 Micro coupures e Pr cautions Pour garantir la conformit avec la directive de compatibilit lectromagn tique CEM les pr cautions suivantes doivent tre observ es a Connectez le g n rateur des appareils utilisant des c bles de haute qualit b Apr s ouverture du boitier pour quelque raison que ce soit v rifiez que toutes les connections de signaux et de masse sont r tablies correctement avant de remettre en place le capot V rifiez que les vis de montage sont correctement remises en place et serr es c Dans le cas de remplacement
28. altern es de la touche SWEEP et le temps de rampe est r gl 200ms ou moins alors changer la fr quence BEG ou END annulera le balayage pr sent recalculera les pas de fr quence et d marrera un nouveau balayage chaque changement de fr quence il est ainsi plus rapide de faire des changements avec le balayage d sactiv La fr quence MARKER cependant peut tre chang e sans interruption de balayage Un second marqueur est aussi affich au r glage fr quence du menu principal ex la fr quence r gl e pour le g n rateur en mode non balayage Ceci offre l avantage d un marqueur ajustable du m me menu utilis pour contr ler l amplitude l offset etc Le signal marqueur est sorti de la prise TRIG SWEEP OUT du panneau arri re voir section connexions pour fonctionnement balayage La sortie est basse OV pour la dur e du balayage avec des impulsions d environ 1V la fr quence marqueur Notez que la largeur de l impulsion marqueur est celle de la dur e du pas fr quence avec la valeur la plus proche de la fr quence marqueur Ceci signifie que des balayages avec peu de pas auront des marqueurs plus larges que ceux avec plus de pas voir section r solution de pas fr quence 4 3 4 R glage mode balayage p riode rampe et source Presser les touches FIELD pour d placer le curseur travers chaque zone ditable de la premi re page du menu balayage ceci l envoie la page ci dessous MODE BEG END LAW LOG
29. and their lamps also light when selected All parameters can be copied from one step to the next step by entering the new step in the n field and pressing RECALL the differences in the new step can then be entered as described above This provides a quick means of creating new steps when only 1 or 2 parameters change GX1010 4 8 2 Defining the Sequence and Timing All 16 steps always contain a set up even if this is only the default setting When set to run the HOP sequence will start at step 00 and execute steps in chronological order up to the step number defined in the LAST field after which it will go back to step 00 and start again the desired sequence should therefore be set starting at step 00 and the LAST field should be set to the last valid step number Both the control mode internal external or manual remote and internal timing if selected are set with the edit cursor in the rightmost field of the top line of the display the diagram shows the default setting of 1s internal interval Note that each step can be set to a different length or a different mode it is therefore possible to mix internally timed steps with externally triggered or manually initiated steps The internal timer can be set from 2ms to 65s in 1ms increments using the rotary control or direct keyboard entry see Timing Considerations section for further information With the interval set to 00 002s 2ms further anticlockwise movement of the rotary contr
30. au courant des dangers encourus doit ex cuter les taches susmentionn es Attention Certains condensateurs internes peuvent conserver un potentiel dangereux m me apr s avoir mis l appareil hors tension Garantie Le mat riel METRIX est garanti contre tout d faut de mati re ou vice de fabrication conform ment aux conditions g n rales de vente Durant la p riode de garantie les pi ces d fectueuses sont remplac es le fabricant se r servant la d cision de proc der soit la r paration soit au remplacement du produit En cas de retour du mat riel au SAV METRIX ou une agence r gionale METRIX le transport aller est la charge du client La garantie METRIX ne s applique pas aux cas suivants 1 R parations suite une utilisation impropre du mat riel ou par association de celui ci avec un quipement incompatible 2 Modification du mat riel sans autorisation explicite des services techniques de METRIX 3 R parations r sultant d interventions effectu es par une personne non agr e par l entreprise 4 Adaptation une application particuli re non pr vue par la d finition du mat riel ou par la notice de fonctionnement Le contenu de cette notice ne peut tre reproduit sous quelque forme que ce soit sans l accord de METRIX Maintenance Pour tout probleme de maintenance de pi ces d tach es de garantie ou autre veuillez prendre contact avec l agence r gionale METRIX Celle ci donnera une
31. avant que l analyseur puisse commencer la commande suivante la file d attente d entr e Les commandes sont transmises en tant que lt PROGRAM MESSAGES par le contr leur et chaque message est constitu de z ro l ment ou de plus d l ments lt PROGRAM MESSAGE UNIT gt s par s par les l ments lt PROGRAM MESSAGE UNIT SEPARATOR gt Les lt PROGRAM MESSAGES gt sont s par s par des l ments lt PROGRAM MESSAGE TERMINATOR constitu s du caract re de nouvelle ligne OAH Un lt PROGRAM MESSAGE UNIT SEPARATOR gt est le point virgule 3BH Un lt PROGRAM MESSAGE UNIT gt est l une des commandes de la section COMMANDES A DISTANCE Les r ponses de l instrument au contr leur sont transmises en tant que lt RESPONSE MESSAGES gt Un lt RESPONSE MESSAGE gt est compos d un lt RESPONSE MESSAGE UNIT gt suivi d un lt RESPONSE MESSAGE TERMINATOR Un lt RESPONSE MESSAGE TERMINATOR gt est le caract re retour de chariot suivi du caract re de nouvelle ligne ODH OAH Chaque interrogation produit un lt RESPONSE MESSAGE gt sp cifique list avec la commande dans la section COMMANDES A DISTANCE Il n est pas tenu compte de lt WHITE SPACE gt sauf dans les identificateurs de commande par exemple C LS n est pas quivalent CLS lt WHITE SPACE gt est d fini comme le code de caract res OOH a 20H inclus l exception des codes sp cifi s comme les commandes d interface ARC Il n est pas tenu compte d
32. avec une r solution de 3 digits de 0 01s 10ms 999s Le choix du temps de rampe affecte le nombre de pas de fr quence discr te dans le balayage les balayages plus rapides auront moins de pas voir section r solution de pas fr quence GX 1010 23 4 4 24 Le mode d clench du balayage est r gl avec le curseur dans la zone TRIG SRC les options sont CONTINUOUS EXTerne et MAN REMOTE en mode CONTINUOUS le balayage part simultan ment avec la transition haut bas du signal TRIG SWEEP OUT le balayage d marre avec une phase 0 et le niveau de sortie r gl par l offset DC A la fin du balayage le signal retourne ce niveau d offset DC et le signal TRIG SWEEP OUT remonte simultan ment Apr s par exemple un temps assez long pour une trace d oscilloscope le cycle se r p te En mode EXTerne un signal d clencheur est connect a la borne EXT TRIG du panneau avant Un balayage d marre 200 800us apr s le front montant du signal d clencheur le balayage est compl t avant qu une autre front de d clenchement soit reconnue et qu un nouveau balayage soit initialis La largeur d impulsion minimale de d clenchement est 1ms et la vitesse de r p tition doit tre gt 1 1 x temps balayage 5 ms En mode MAN REMOTE un simple balayage est lanc par pression de la touche MAN SYNC ou par chaque ordre d une commande Si la touche MAN SYNC est press e durant un balayage lent le balayage sera en pause sa f
33. bloc de donn es compos de caract res hexad cimaux d approximativement 842 octets PRE lt nrf gt R gle le parallel Poll Enable Register a la valeur lt nrf gt PRE Renvoie la valeur dans le parallel Poll Enable Register sous le format num rique lt nrf gt RCL lt nrf gt Rappelle les r glages contenus dans un une m moire lt nrf gt RST R initialise les param tres de l instrument en leur attribuant leurs valeurs par d faut SAV lt nrf gt Sauvegarde tous les r glages de l instrument dans une m moire lt nrf gt SRE lt nrf gt R gle le Service Request Enable Register sur lt nrf gt Si la valeur de lt nrf gt SRE Renvoie la valeur du Service Request Enable Register sous le format num rique lt nr1 gt 52 GX 1010 STB TRG TST WAI ABORT AM lt cpd gt AMDEPTH lt nrf gt AMSRC lt cpd gt AMWAVE lt cpd gt ARB ARB ARBRCLe lt nrf gt ARBSAV lt nrf gt lt cpd gt AUX lt cpd gt BCNT lt nrf gt BEEP BEEPMODE lt cpd gt CLOCKBNC lt cpd gt DBM lt nrf gt DCOFFS lt nrf gt EER EMFPP lt nrf gt EMFRMS lt nrf gt FILTER lt cpd gt FREQ lt nrf gt FSK lt cpd gt FSKFRQA lt nrf gt FSKFRQB lt nrf gt FSKPERA lt nrf gt FSKPERB lt nrf gt FSKSRC lt cpd gt GATE lt cpd gt GATE SRC lt cpd gt HOP lt cpd gt lt nrf gt LRN lt character data gt NEGPUL GX 1010 Renvoie la valeur du Statut Byte Register sous le format num
34. can be created by using the internal trigger generator to produce the long interval between the pulses with each pulse being a single cycle of the main generator Set the main generator to 10kHz by pressing FREQ 1 0 kHz and reduce the duty cycle to 1 99 i e pulse width 1us by pressing SYM 1 Select the Trigger menu by pressing EDIT TRIG and set SOURCE TGEN i e internal trigger generator The TGEN period should be at its default setting of 1 00ms 1 000kHz and the burst count set to 0001 The default phase setting of 0 corresponds to the top of the rising edge of the pulse and starting at this phase will not give the desired result set the phase to 90 by moving the cursor to the PHASE field with the FIELD keys and enter 9 0 CONFIRM Whilst still in the Trigger menu press TRIG again to turn Trigger mode on Ho MAIN GEESS E CH PER KN SYM 4 TGEN PERIOD _ gt A single cycle of the main generator i e a single pulse will now be output at the default frequency of 1kHz a 1000 1 duty cycle has now been achieved Move the cursor to the TGEN period field with the FIELD keys and increase the period using the rotary control although it will be difficult to see on the oscilloscope the 1us pulsewidth is maintained down to mHz repetition rates i e a very small duty cycle Note that at Main generator frequencies above 30kHz phase control of pulse waveforms is restricted unless wavefor
35. countries and the METRIX logotypes are registered METRIX reserves the right to modify specifications and prices as required by technological improvements GX1010 Il 3 2 1 2 2 2 3 2 4 2 5 4 11 GENERAL DESCRIPTION This Programmable Function Generator uses direct digital synthesis to provide high performance and extensive facilities at a breakthrough price lt can generate a variety of waveforms between 0 1mHz and 10MHz with a resolution of 7 digits and an accuracy better than 10ppm Direct digital synthesis for accuracy amp stability Direct digital synthesis DDS is a technique for generating waveforms digitally using a phase accumulator a look up table and a DAC The accuracy and stability of the resulting waveforms is related to that of the crystal master clock The DDS generator offers not only exceptional accuracy and stability but also high spectral purity low phase noise and excellent frequency agility A wide range of waveforms High quality sine square and pulse waveforms can be generated over the full frequency range of 0 1mHz to 10MHz Triangle waveforms ramp waveforms and multi level squarewaves can also be generated but with limitations as to the maximum useable frequencies Variable symmetry duty cycle is available for all standard waveforms e Arbitrary waveform capability Arbitrary waveforms can be loaded via the digital interfaces and then used in a similar way to the standard wavef
36. de la prise TRIG SWEEP OUT 7 2 1 5 SORTIES e Sortie principale Imp dance de sortie 50Q ou 6000 Amplitude 5mV 20V cr te cr te circuit ouvert 2 5mV a 10V cr te cr te dans 50Q 600Q La sortie peut tre sp cifi e comme EMF valeur circuit ouvert ou P D diff rence de potentiel cr te cr te r m s ou dBm Pr cision d amplitude typique 3 1mV 1kHz dans 5002 6004 nettet d amplitude 0 2dB 200 kHz 1dB 5 MHz 2 5dB 10 MHz Gamme de d calage continu 10V d calage continu plus cr te du signal limit e 10V sur 500 6000 Pr cision de d calage continu 3 10mV non att nu R solution 3 chiffres ou 1mV pour Amplitude et d calage continu Aberrations d impulsion lt 5 2mV e Sortie auxiliaire Aux Out Niveaux CMOS TTL avec sym trie et fr quence de la sortie principale et la phase du r glage de phase Start Stop e Sortie d clenchement balayage Trig Sweep Out Sortie multifonctions d pendant du mode Except en mode balayage et saut HOP la sortie est celle du g n rateur de d clenchement de niveaux CMOS TTL 1kQ En mode balayage la sortie est un signal 3 niveaux passant de haut 4V bas OV en d but de balayage avec des impulsions d environ 1V chaque marqueur En mode HOP la sortie passe l tat z ro au d but de chaque s quence suivie par un front montant apr s que la fr quence et la forme du signal aient t modifi pour
37. des signaux 4 50 63 FREQ PER 14 33 Fr quence de Modulation 27 FSK 4 25 29 49 62 65 L Garantie 2 GATE 10 25 29 65 GPIB 5 9 13 42 46 H HF AUX 61 HOP 32 33 34 50 64 D GE Imp dance de sortie 15 Impulsion 55 56 64 Interfaces 38 Cr LAW 23 LOW FREQ 20 62 M MAIN 62 MAIN OUT 10 12 15 Maintenance 2 8 MAN SYNC 10 Marqueurs 22 Messages d alerte et d erreur 17 MISE EN ROUTE 43 MODE 10 Modulation d amplitude 4 10 25 27 29 49 65 66 Modulation de fr quence 65 N Niveau de sortie 14 NUMERIC UNIT 10 O OUTPUT 10 12 53 55 66 Overshoot 58 p P riode rampe 23 PHASE 66 Phase de d part et d arr t 26 64 65 Pr cautions 1 Pr cision 4 Profondeur de Modulation 28 R RAM 9 Rappels 34 Rapport cyclique 56 R emballage 2 REGISTRES D ETAT 44 R glage de fr quence 29 R glages 35 36 RS 232 5 9 13 S Salve d clench e 25 Salves 24 64 S curit 1 S quence 33 SET 10 Signaux arbitraires 4 31 49 64 Signaux carr s 19 64 Source de d clenchement 25 29 Stabilit 4 Stockage 34 Style de Curseur 35 Symboles 2 SYMETRIE 17 63 SYNC OUT 13 67 Synchronisation 36 37 Tension d alimentation 6 TGEN 27 56 TRIG 13 18 24 26 27 29 66 V VCA IN 28 12 V rouillage de phase 5 52 W Wobulation 4 73 GX 1010 PROGRAMMABLE 10 MHZ DDS FUNCTION GENERATOR OPERA
38. does Procedure de Calibrators aa A as 7 24 Maea eege eege ee 8 4 DESCRIPTION FONCTIONNELLE sss coos sacpeets sane seessasheves covanesetmexsececatastes it 9 AEN STIS EE 9 4 1 1 Principes Synth se Num rique Directe DDS oooooocccccncccccoccccccccccconanananncccnnncnnnannnnnnnnnos 9 412 Mise mane coat 9 4 1 3 Contraste de l affichage e mis denis dla anses dada 10 i ER LEE N Ee EE 10 4 1 5 Principes d dition E EE EE en nue 11 4 1 6 Connexions Panneau AVANT asi dE me Ane ate LT EE edhe oak anu eens 12 4 1 7 Connexions Panneau Arri re iii 12 4 2 Fonctions de Dania entres 14 GX 1010 TABLE DES MATIERES 4 2 1 Param tres du g n rateur principal 14 4 2 2 SOMO ET 18 4 2 3 G n ration el nn eee le E erte meet E 20 4 3 Fonctionnement en balayage sweep nn nana nn nn ncnnnnnnns 22 E CAMS FASS EEE AR SR RTE RSR EE A tt arene 22 4 3 2 Connexions pour le fonctionnement en balayage 22 4 3 3 R glage de la port e de balayage et marqueurs cccconocccccccconononcccnnnnnnanncccnnnnnnnnnancnnnns 22 4 3 4 R glage mode balayage p riode rampe et source 23 4 3 5 R solution de pas en fr quence ss 24 4 4 Salve d clench e et porte GATE is 24 4 4 1 G n rateur de d clenchement interne 25 4 4 2 Entr e de d clenchement externe ss 25 4 4 3 Salve COCINAS cil lina 25 4 4 4 Mode porte GATE raie cs 26 AS Modulation d Amplitude ette mo laa ds 27 4 5 1 Modulation d Ampl
39. each burst following the trigger is set with the edit cursor in the BURST COUNT field Entries can be made direct from the keyboard or by rotary control the burst range is 1 to 1023 with a resolution of 1 cycle or 0 5 to 511 5 with a resolution of 0 5 cycles The first cycle starts and the last cycle stops at the phase set in the PHASE field GX1010 Il 25 26 Il 4 4 3 3 Start Stop Phase The start and stop phase of the triggered burst is set in the PHASE field The PHASE field actually sets the phase of the Auxiliary Output and it is from this output that control of the start and stop point of the main generator is derived the rising edge of the AUX OUT signal which can be phase shifted with respect to the MAIN OUT determines the start and stop point of the main waveform burst Consequently the conditions under which the Auxiliary Output phase shift is constrained and which are fully explained in that section all apply to start stop phase For example the start stop phase of sine and triangle waveforms cannot be adjusted for main output frequencies above 30kHz unless the AUX OUTPUT field on the Options menu is set to LOW FREQuency generation mode because only in this mode does the AUX OUT continue to be phase shifted with respect to MAIN OUT Because the phase control signal is derived from the Auxiliary Output waveform further considerations apply as the main generator frequency is increased With AUX OUTPUT LOW FREQ on the Options
40. entr 1 0 0 mV ou 1 V etc Le logiciel agit intelligemment dans certaines situations par exemple m me si EMF ou PD est choisie entrer un nombre suivi de la touche dBm donnera une valeur dBm De la m me mani re avec dBm choisie entre un nombre suivi de V ou mV donnera une valeur PD Vrms OdBm est 1mW dans l imp dance sp cifi e les niveaux des signaux bas sont sp cifi s en utilisant la touche pour entrer un dBm n gatif Voir aussi le dernier paragraphe de cette section pour l utilisation de la touche pour inversion de sortie Bouger le curseur d dition vers la zone num rique permet de faire varier la valeur par la molette avec un pas d termin par la position du curseur dans la zone Les touches FIELD bougent le curseur dans la ligne et les touches DIGIT le bougent dans la zone valeurs ceci est plus expliqu dans la section Principes d dition Bouger le curseur vers les zones unit s permet de changer la valeur par dizaine avec les touches DIGIT ou la molette le point d cimal et ou les unit s changeront respectivement D autres incr ments seront impossibles si l on est moins d une d cade de la limite sup rieure ou inf rieure L avance par dizaine avec les touches DIGIT ou la molette est aussi impossible quand le niveau est affich en dBm O que soit le curseur sur la seconde ligne de l affichage des pressions altern es de la touche inverseront la sortie MAIN OUT de sortie si DC OFFS
41. est maintenu passe de 20Vpp EMF 10Vpp EMF quand la modulation passe de 0 100 4 5 1 3 Forme de signal de Modulation Le signal d faut de modulation est un signal carr e parce que ceci permet la gamme compl te de fr quence du g n rateur d clenchement interne d tre utilis e Alternativement une signal sinus de 1kHz peut tre choisie en bougeant le curseur vers la zone INT MOD la derni re ligne de l afficheur les touches DIGIT ou la molette peuvent tre utilis s pour changer le r glage entre SQUARE la fr quence r gl e sur le g n rateur d clenchement interne et SINE Notez que choisir SINE force la zone TGEN afficher 1 00ms 1 000kHz mais le r glage utilisateur n est pas perdu et si INT MOD SQUARE est res lectionn le r glage TGEN retourne sa valeur d origine 4 5 2 VCA Externe Avec le curseur dans la zone SOURCE du menu AM r gler la source EXT VCA Connecter le signal modulant la borne VCA IN du panneau arri re imp dance nominale d entr e 6kQ une tension positive augmente la sortie g n rateur et une tension n gative diminue la sortie Notez que comme avec AM interne une distorsion surviendra si la combinaison du r glage g n rateur et du signal VCA tente de piloter la sortie au dessus de 20Vpp EMF AM externe s accomplit en r glant le g n rateur au niveau de sortie requis et en appliquant le signal de modulation qui peut tre coupl a AC si n cessaire au nivea
42. et une fr quence d horloge de 2 x 10 27 487mHz ceci produit une r solution de fr quence correspondant la plus petite phase d incr mentation de fcLk 2 0 1mHz Seuls les 10 bits les plus significatifs de l accumulateur de phase sont utilis s pour adresser la RAM Pour une fr quence de forme du signal de fCLK 1024 26 84kHz la fr quence naturelle l adresse RAMS incr mente sur chaque coup d horloge Pour toutes les fr quences situ es en dessous de celle ci c est a dire pour des incr mentations de phase plus petites une ou plusieurs adresses sont sorties pendant une p riode plus grande que celle de l horloge car l incr mentation de phase n est pas assez grande pour chelonner l adresse chaque coups d horloge De m me les fr quences des formes des signaux situ es au dessus de la fr quence naturelle ont donc une incr mentation de phase plus grande Ceci implique que certaines adresses ne sont pas prises en compte Ainsi la forme du signal a t chantillonn e Diff rents points seront chantillonn s dans les cycles successifs du signal Le nombre minimum de points n cessaires afin de reproduire de fa on pr cise une forme de signal d termine la fr quence de sortie maximale utilisable fmax fCLK No de points Dans le cas des signaux sinuso daux le filtre permet la forme de signal d tre reproduite pr cisement jusqu la limite Nyquist fCLK 2 bien que sur ce g n rateu
43. gt lt PROGRAM MESSAGE TERMINATOR gt lt rmt gt lt RESPONSE MESSAGE TERMINATOR gt lt cpd gt lt CHARACTER PROGRAM DATA Le a short mnemonic or string such as ON or OFF lt nrf gt A number in any format e g 12 12 00 1 2 el and 120 e 1 are all accepted as the number 12 Any number when received is converted to the required precision consistent with the use then rounded up to obtain the value of the command lt nri gt A number with no fractional part i e an integer lt nr2 gt A number in fixed point format e g 11 52 0 78 etc ad Any item s enclosed in these brackets are optional parameters If more than one item is enclosed then all or none of the items are required The commands which begin with a are those specified by IEEE Std 488 2 as Common commands All will function when used on the ARC interface but some are of little use 5 2 1 Function Selection SINE Set sine function SQUARE Set square function TRIAN Set triangle function POSPUL Set positive pulse function NEGPUL Set negative pulse function POSRAMP Set positive ramp function NEGRAMP Set negative ramp function STAIR Set staircase function ARB Set arbitrary function NOISE Set NOISE lt ON gt or lt OFF gt lt cpd gt 5 2 2 Main Generator Parameters OUTPUT lt cpd gt Set output lt ON gt lt OFF gt lt NORMAL gt or lt INVERT gt FREQ lt nrf gt Set main frequency to lt nrf gt Hz PER lt nrf gt Set main period to lt nrf gt secon
44. in sequence at a rate determined by either the internal timer an external trigger a remote command or from the keyboard Each waveform can be set to any waveshape except noise frequency amplitude and offset Frequency only changes are phase continuous e Noise White noise output with a typical 3dB bandwidth of 0 03Hz to 700kHz Amplitude and offset adjustable Noise can only be used with Gated and AM modulation modes 7 2 1 4 MODULATION MODES e Trigger Burst Phase coherent signal keying each positive edge of the trigger signal will produce one burst of the carrier starting and stopping at the phase angle specified by the Start Stop phase setting Carrier frequency 0 1mHz to at least 1MHz Carrier waveforms All Number of cycles 1 to 1023 resolution 1 cycle or 0 5 to 511 5 resolution 0 5 cycle Trigger rep rate dc to 50 kHz internal dc to 1MHz external Source Internal from keyboard or trigger generator External from EXT TRIG input or remote interface e Gated GX1010 Il 61 62 Il Non phase coherent signal keying output carrier wave is on while Gate signal is high and off while low Carrier frequency From 0 1 mHz to 10 MHz Carrier waveforms All Trigger rep rate dc to 50 kHz internal dc to 1 MHz external Gate signal source Internal from keyboard or trigger generator External from EXT TRIG input or remote interface e Sweep Carrier Waveforms All Sweep Mode Linear or logarithmic si
45. it even as an ARC address 5 1 2 ARC Interface 5 1 2 1 ARC Interface Connections The 9 way D type serial interface connector is located on the instrument rear panel The pin connections are as shown below Pin Name Description 1 No internal Connection 2 TXD Transmitted data from instrument 3 RXD Received data to instrument 4 No internal connection 5 GND Signal ground 6 No internal connection GX1010 Il 37 38 Il 7 RXD2 Secondary received data see diagram 8 TXD2 Secondary transmitted data see diagram 9 GND Signal ground Pins 2 3 and 5 may be used as a conventional RS232 interface with XON XOFF handshaking Pins 7 8 and 9 are additionally used when the instrument is connected to the ARC interface Using a simple cable assembly a daisy chain connection system between any number of instruments up to the maximum of 32 can be made as shown below CONTROLLER INSTRUMENT INSTRUMENT INSTRUMENT 1 e 3 TO NEXT INSTRUMENT The daisy chain consists of the transmit data TXD receive date RXD and signal ground lines only There are no control handshake lines This makes XON XOFF protocol essential and allows the inter connection between instruments to contain just 3 wires The wiring of the adaptor cable is shown below 9 WAY D 9 WAY D FEMALE MALE O1 O2 TX OO 3 RX O4 5 GND Os O7 O8 O9 LINKS TO CONTROLLER pene R CHAIN O lt O 000000 9 WAY D
46. l entr e du nombre et de l unit Notez que contrairement FREQ ou EMFs le curseur ne bouge pas dans le nom DC OFFSET parce qu il n a pas d alternative Avec le curseur dans la zone num rique tourner la molette incr mentera ou d cr mentera la valeur par pas d termin s par la position du curseur dans la zone les touches DC OFFSET ou FIELD bougent le curseur dans la ligne et les touches DIGIT le bougent dans la zone ceci est expliqu dans la section Principes d dition Parce que l offset DC peut avoir des valeurs n gatives la molette peut aller au dela de z ro bien que laffichage change de r solution l approche de z ro la taille de l incr ment est maintenue quand l offset est n gatif Par exemple si il est affich DC 205 mV avec le curseur sur le digit le plus lev la molette d cr mentera l offset par pas de 100mV comme suit DC 205 mV DC 105 mV DC 5 00 mV DC 95 0 mV DC 195 mV La touche peut tre aussi utilis e n importe quand pour rendre la valeur offset n gative des pressions altern es changent en et vice et versa De la m me fa on le signe de offset peut tre consid r comme une partie d une nouvelle valeur ex si l offset est 2 00V il peut tre chang en 100mV en appuyant sur 1 0 0 mV L offset DC r el la borne MAIN OUT principal est att nu par bonds quand il est en service L offset du signal n tant pas toujours possible
47. la nouvelle s quence 7 2 1 6 ENTREES e D clenchement Ext Ext Trig Gamme de fr quence 0 1 MHz Gamme de signal Seuil au niveau TTL entr e max 10V largeur d impulsion minimum 50ns pour les modes d clenchement porte et FSK 1ms pour les modes balayage et HOP Imp dance d entr e 10kQ e Entr e VCA modulation d amplitude Gamme de fr quence 0 a 100 kHz Gamme de signal 2 5V pour modulation 100 a la sortie max Imp dance d entr e 6kQ 7 2 1 7 VERROUILLAGE DE PHASE Les signaux de ces bornes sont utilis s pour verrouiller la phase de 2 ou plusieurs g n rateurs e Entr e Sortie horloge Niveau seuil TTL CMOS comme entr e Niveaux de sortie logique 1v et 4V sur 50Q en sortie GX 1010 7 3 e Sortie synchro Sync Out Niveaux de sortie logique TTL CMOS sur 50Q 7 2 1 8 INTERFACES Toute une gamme de commandes a distance est disponible via RS232 ou GPIB RS232 Vitesse de transmission variable 9600 Baud max Connecteur 9 broches D IEEE 488 Conforme IEEE488 1 et IEEE488 2 7 2 2 S curit CEI 1010 1 NFC 42020 1993 Cat gorie d installation des entr es CAT 10V max Cat gorie d installation de l alimentation CAT II 264V max Degr de pollution 1 Isolation classe 1 Altitude lt 2000m 7 2 3 Informations g n rales Dimensions hauteur 130mm largeur 212mm longueur 330mm Poids 4 1kg Alimentation 230V 115V ou 100V en nominal 50 60Hz
48. last field on the first page of the sweep menu Pressing the right FIELD key will step the cursor through all the editable fields up to TRIGger SouRCe one more press returns the cursor to the first field of the first page Pressing ESCAPE always exits the edit menu and returns to the Main menu With the edit cursor in the MODE field alternate presses of the DIGIT keys or turning the rotary control will set the sweep direction to BEGin END or END BEGin There are no restrictions on the BEGin and END frequencies e g the BEGin frequency can be higher than the END frequency so the MODE field simply provides an easy way to reverse the sweep direction With the edit cursor in the LAW field the sweep can be changed from LINear to LOGarithmic With LAW LIN set the frequency changes linearly with time across the sweep with LAW LOG set the frequency changes exponentially with time across the sweep The term log sweep is a convention with the start frequency lower than the stop frequency the usual mode of operation the mathematical relationship of frequency to time is actually anti log The sweep rate is set with the cursor in the RAMP TIME field ramp time can be set with 3 digit resolution from 0 01s 10ms to 999s The choice of ramp time affects the number of discrete frequency steps in the sweep faster sweeps will have fewer steps see Frequency Stepping Resolution section The trigger mode of the sweep is set with the cursor in the T
49. menu phase shift control is still available above 30kHz but real hardware delays become increasingly significant such that the start stop phase increases for no change in phase setting this shift is caused by the delay between AUX OUT and MAIN OUT becoming more significant and by the delays in the burst count and phase control circuit themselves These delays can be equivalent to say a 45 phase shift at 1MHz however by backing off the required phase shift by 45 the desired condition can still be achieved At the same time howver the fewer samples making up each cycle of the waveform means that the start stop point becomes an uncertain band which is 1 clock wide Note that these effects apply even when the phase is set to 0 at frequencies approaching 10MHz the phase shift can be 90 or more and the uncertainty band becomes wide Because this effect is seen at 0 phase it is also evident when AUX OUTPUT is in HIGH FREQuency mode i e when there is no phase control In fact because the AUX OUT signal is derived from the filtered DDS sinewave in this mode the filter adds further phase delay creating even longer phase shifts at a given frequency than are evident with AUX OUTPUT in LOW FREQuency mode In summary phase errors and uncertainty will increase as the main frequency is increased above 30kHz even with 0 phase set However stop start phase control can be used with care to much higher frequencies by backing off
50. mode TRIG GATE AM etc on or off and to select the menus for setting up these special functions Alternate presses of a MODE key will turn the function on or off when on the associated lamp is lit Pressing the blue EDIT key followed by a MODE key displays the edit menu for that mode the associated lamp flashes whilst the edit menu is displayed e UTILITIES keys give access to the STORE RECALL and Interface parameter menus the MAN SYNC key is used for manual triggering and synchronising two or more generators when suitably connected together e Lastly the CONFIRM ESCAPE and CE Clear Entry keys have self explanatory functions Numeric entries are automatically confirmed when the appropriate unit key Hz kHz MHz etc is pressed but CONFIRM can be used to enter a number in the parameter s basic units or to confirm entries with fixed units e g phase or no units e g burst count It is also used to confirm certain options when prompted Pressing ESCAPE returns a setting being edited to its last value a second press when appropriate will return the display from an edit menu to the Main menu CE Clear Entry undoes a numeric entry digit by digit Further explanations will be found as appropriate in the detailed descriptions of the generator s functions GX1010 4 1 5 Principles of Editing FIELD and DIGIT keys are used together with the rotary control to edit parameters shown on the current menu The Main menu show
51. need resetting when changing between waveshapes Also select STAIR and ARBitrary waveshapes to view the default settings With SINE or TRIANGLE selected again move the flashing edit cursor into the numeric field of the EMF value using the FIELD keys Using the DIGIT keys move the cursor through the numeric field to the digit representing 1V increments then adjust the amplitude with the rotary control Using the keyboard enter 1 0 V to restore the output level to 10Vpp Move the cursor to the Symmetry field with the SYM key and observe the effect of adjusting symmetry with the rotary control Restore 50 symmetry by entering 5 0 from the keyboard Pulse Trains To demonstrate simple pulse waveforms for digital applications select PULSE and press EMF 4 V DC OFFSET 0 8 V FREQ 1 kHz This setting will give the standard TTL levels of 2 4V and 0 4V into 50Q as a 1 1 duty cycle 1kHz pulse train Move the cursor to the Symmetry field with the SYM key and adjust the symmetry with the rotary control to create pulses with different mark space ratios GX1010 Il 53 54 Il a PERXSYM gt 4 PERx 1 SYM gt gt lt PERIOD gt Using this technique the duty cycle range is limited to that achievable with the symmetry control 99 1 For very small duty cycles at lower repetition rates the triggering facilities may be used see next section 6 3 1 Low Duty Cycle Pulse Trains These
52. num rique directe pour la pr cision et la stabilit La synth se num rique directe DDS est une technique visant g n rer des signaux num riquement en utilisant un accumulateur de phase une table d exploration et un DAC Convertisseur Analogique Num rique La pr cision et la stabilit des signaux r sultantes sont proches de celles du quartz d horloge interne Le g n rateur DDS offre non seulement une pr cision et une stabilit exceptionnelles mais encore une haute puret spectrale un bruit de phase tr s bas et une excellente souplesse dans les fr quences Une large gamme de formes de signaux Des signaux sinuso daux carr s et des impulsions de haute qualit peuvent tre g n r s sur toute la gamme de fr quence de 0 1mHz 10Mhz Des signaux triangulaires en rampe et des signaux carr s niveaux multiples peuvent tre aussi g n r es dans la limite des fr quence maximum utilisables Un rapport cyclique sym trique variable est disponible pour toutes les formes de signaux e Fonction signaux arbitraires Des signaux arbitraires peuvent tre charg s via les interfaces num riques et utilis s de la m me fa on que les signaux standards Jusqu 5 formes arbitraires de signaux de 1024 mots de 10 bits peuvent tre stock s dans la m moire non volatile L horloge de forme de signaux peut atteindre 27 48 MHZ Cette fonction accro t consid rablement la souplesse de l instrument faisant de lui u
53. op ration ARB a l exception de ARB d truira les donn es Les donn es des formes de 49 signaux seront aussi perdues une fois l instrument teint moins d avoir t auparavant sauvegard es ARBRCL lt nrf gt Rappelle les formes de signaux arbitraires du stockage lt nrf gt ARB Pose une requ te a la forme de courbe s lectionn e arbitrairement et r pond SETARB lt 1024 nr1 gt lt rmt gt 5 2 8 Options sur les G n rations de Formes de signaux SQRWAVGEN lt cpd gt Fixe le mode g n ration signal carr e sur lt AUTO gt lt HF gt ou lt LF gt FILTER lt cpd gt R gle le mode filtre sur lt AUTO gt lt ON gt ou lt OFF gt AUX lt cpd gt R gle le mode de sortie AUX sur lt AUTO gt lt HF gt ou lt LF gt SWPTRGOUT lt cpd gt R gle le mode de la bnc de sortie balayage tgen sur lt AUTO gt lt SWEEP gt ou lt TGEN gt 5 2 9 Commandes HOP HOP lt cpd gt lt nrf gt Fixe l tat HOP sur lt RUN gt ou lt OFF gt avec la derni re tape fix e lt nrf gt SETHOP lt nrf gt lt nrf gt Les donn es pour une tape de la s quence sont lt nrf gt lt nrf gt lt cpd gt lt nrf gt lt tape gt lt temps gt lt freq gt lt niveau gt lt fonc gt lt dEcalage gt lt Etape gt est le num ro de l tape tre d finie lt temps gt est le temps en secondes qu il reste cette tape S il est fix O MANUAL sera s lectionn S il est fix 3 EXTERNAL sera s lecti
54. other than 50 are unfiltered It may be desirable to force the filter ON under some circumstances to improve waveform quality e g for higher frequency sinewaves that are only slightly asymmetric e Similarly asymmetric HF squarewaves pulses and AUX outputs generated from the comparator will be improved if the filter is forced ON to filter the signal driving the comparator e when staircase arbitrary or LF mode squarewaves pulses are selected the comparator is driven by the unfiltered main waveform With all except squarewaves it is possible to have a waveshape which never crosses the comparator threshold thus HF AUX output may be permanently high or low To avoid this situation the default AUTO AUX setting is LF mode however in this mode edge jitter will become increasingly significant at higher frequencies GX1010 e Phase shift between MAIN and AUX at higher frequencies only possible by setting AUX to LF mode will be different for those signals which are unfiltered compared to those which by default have the filter in the signal path For example HF squarewaves pulses from the comparator will be further phase shifted compared to LF mode squarewaves of the same frequency because the sinewave driving the comparator is significantly delayed by the filter e Setting squarewaves pulses to LF mode at higher frequencies will also introduce 1 clock edge uncertainty on the AUX output even if this is still set to AUTO or HF because the
55. peut tre chang sur le menu ERReur accessible en pressant la touche bleue EDIT suivi de la touche ERReur touche 2 Le menu ERReur est ci dessous ERROR BEEP ON ERROR MESSAGE ON WARNING BEEP ON WARNING MESSAGE ON Le curseur clignotant peut tre boug a travers chacune des quatre lignes en utilisant les touches FIELD La zone passe de ON OFF par les touches DIGIT ou la molette Si un nouveau r glage est n cessaire pour une utilisation ult rieure il devrait tre sauv en changeant le r glage POWER UP dans le menu mode d op ration POWER UP POWER DOWN voir la section mode d op ration 4 2 2 Sortie auxiliaire AUX OUT est une sortie niveau TTL CMOS synchronis e avec MAIN OUT et avec la m me sym trie Cependant la phase de AUX OUT peut varier en changeant le r glage PHASE dans le menu TRIG GX 1010 4 2 2 1 Phase de sortie auxiliaire Triangle en Rampe AUX 0 AUX 90 AUX 180 0 180 360 La convention adopt e pour la phase dans cet instrument est illustr e dans le sch ma 0 est toujours la premi re donn e du signal en m moire Sur les signaux sym triques 0 est le point croisement 0 du front montant pour les signaux sinus carr triangle et impulsion 0 est le point de d part des signaux rampe escalier et arbitraire Quand la phase est r gl e 0 la rampe montante de AUX OUT est aussi 0 Quand la phase est positive ex 9
56. r tablis power up ou POWER UP n importe lequel des r glages stock s dans les m moires permanentes 1 a 9 POWER UP DEFAULTS r tablit les r glages tablis par d fauts voir annexe 2 4 9 2 4 R glage Clock In Out Le r le de la borne du panneau arri re CLOCK IN OUT est d termin par le r glage dans le champ CLOCK BNC Avec CLOCK BNC OUTPUT r glage par d faut une version interm diaire de l horloge interne est disponible la borne CLOCK IN OUT Quand deux ou plusieurs g n rateurs sont synchronis s le maitre est r gl sur OUTPUT et le signal est utilis pour commander le CLOCK IN OUT des esclaves Avec CLOCK BNC INPUT la prise devient une entr e pour l horloge externe Avec CLOCK BNC PHASE LOCK le g n rateur est dans le mode esclave et la prise CLOCK IN OUT doit tre command e par le g n rateur maitre r gl sur CLOCK BNC OUTPUT Le r glage des modes esclave annule les modes GATE d clenchement balayage et FSK qui tournent Un message d alerte appara t alors quand cette option est s lectionn e et il est n cessaire d appuyer sur CONFIRM afin d ex cuter appuyer sur ESCAPE r tablira les r glages INPUT ou OUTPUT Des d tails plus complets sont donn s dans la section Synchroniser les G n rateurs Synchronisation de plusieurs G n rateurs Deux ou plusieurs g n rateurs peuvent tre synchronis s entre eux en suivant la proc dure d crite ci dessous le nombre de g n rateurs po
57. rateur Principal Quand le menu Principal est affich appuyer sur FREQ 1 kHz EMF 1 0 V puis s lectionner SINE avec la touche FUNCTION Si la DEL de OUT PUT n est pas allum e appuyer sur ON pour l allumer R gler Poscilloscope sur 1V div la base de temps sur 200us div et s lectionner le couplage DC puis observer le signal S lectionner les autres signaux a leur tour en utilisant les touches FUNCTION et observer les diff rences entre les signaux carr et impulsions lors du changement de formes des signaux il est possible que le d clenchement de l oscilloscope ait besoin d tre r initialis S lectionner STAIR escalier et ARBitraire pour visualiser les signaux pr enregistr s Avec SINE ou TRIANGLE s lectionn d placer le curseur clignotant dans le champ num rique de la valeur EMF en utilisant les touches FIELD En utilisant les touches DIGIT d placer le curseur dans le champ num rique vers le caract re repr sentant l incr mentation 1V puis ajuster l amplitude avec le commutateur Avec l aide du clavier entrez 1 0 V afin de restaurer le niveau de sortie 10Vpp D placez le curseur vers le champ Sym trie avec la touche SYM et observez l effet de l ajustement de la sym trie avec le commutateur Restaurer 50 de sym trie en entrant 5 0 avec le clavier Trains d Impulsion Pour voir un exemple des formes d impulsions simples pour des applications digitales s lectionnez PULSE et appuy
58. rend essentiel le protocole XON XOFF et permet l interconnexion entre les instruments de contenir juste 3 fils Le c blage du c ble de l adaptateur est indiqu ci dessous E 9 voies D 9 voies D Male Femelle DCD _ 1 O1 RX 2 O 2 mm TX TX m 30 O3 me RX DTR m A O4 GND SCH 5 GND DSR i E Os RTS 7 O7 CTS 8 O8 RI 90 k Os Mont e Liaison pour Descente vers la vers le contr leur PC chaine 000000 1 8 3 4 5 6 7 8 9 9 voies D Male INSTRUMENT DE LA ll CHAINE TX RX TXIN RXOUT Il faut r gler tous les instruments de l interface la m me vitesse de transmission et ils doivent tre allum s car sinon les instruments de la chaine a guirlande plus loign s ne recevront pas de donn es ni de commandes GX 1010 39 40 Les imp ratifs standard ARC des autres param tres d interface sont les suivants Bits de d but 1 Bits de donn es 8 Parity Aucune Bits d arr t 1 Ces param tres sont fix s dans cet appareil de mesure universel ainsi que c est le cas de la plupart des autres instruments ARC 5 1 2 2 Jeu de caract res ARC Par suite du besoin d tablissement de liaison avec XON XOFF il est possible de transmettre des donn es cod es ASCII uniquement des blocs binaires ne sont pas admissibles Il n est pas tenu compte du bit 7 des codes ASCII car il est consid r comme tant bas On ne fait pas de diff rence entre les majuscules et
59. rmt gt Clear status Clears the Standard Event Status Register Query Error Register and Execution Error Register This indirectly clears the Status Byte Register Set the Standard Event Status Enable Register to the value of lt nrf gt Returns the value in the Standard Event Status Enable Register in lt nr1 gt numeric format The syntax of the response is lt nr1 gt lt rmt gt Returns the value in the Standard Event Status Register in lt nri gt numeric format The register is then cleared The syntax of the response is lt nr1 gt lt rmt gt Returns ist local message as defined by IEEE Std 488 2 The syntax of the response is O lt rmt gt if the local message false or1 lt rmt gt if the local message is true Sets the Operation Complete bit bit 0 in the Standard Event Status Register This will happen immediately the command is executed because of the sequential nature of all operations Query operation complete status The syntax of the response is 1 lt rmt gt The response will be available immediately the command is executed because of the sequential nature of all operations Set the Parallel Poll Enable Register to the value lt nrf gt Returns the value in the Parallel Poll Enable Register in lt nri gt numeric format The syntax of the response is lt nr1 gt lt rmt gt Set the Service Request Enable Register to lt nrf gt If the value of lt nrf gt Returns the value of the Service Request Enable Register i
60. set to 200ms or less then changing the BEGin or END frequency causes the current sweep to be aborted the frequency steps to be recalculated and a new GX1010 sweep started at each frequency change it is therefore faster to make changes with the sweep off The MARKER frequency however can be changed without interrupting the sweep A second marker is also displayed at the frequency set on the main menu i e at the frequency set for the generator in non sweep mode This offers the advantage of a marker adjustable from the same menu used to control amplitude offset etc The marker signal is output from the rear panel TRIG SWEEP OUT socket see Connections for Sweep Operation section The output is low OV for the duration of the sweep with narrow 1V pulses at the marker frequency Note that the marker pulse width is that of the duration of the frequency step with the closest value to the marker frequency This means that sweeps with few steps will have wider markers than those with many steps see Frequency Stepping Resolution section 4 3 4 Setting Sweep Mode Ramp Time and Source Pressing the FIELD keys to move the cursor through each editable field of the first page of the sweep menu eventually steps the cursor onto the second page shown below MODE BEG END LAW LOG RAMP TIME 0 05 S TRIG SRC CONTINUOUS MORE gt gt gt Pressing the left FIELD key with the cursor in the first MODE field will return the edit cursor to the
61. suite rapide toute commande de pi ces d tach es ou assurera un service rapide de r paration ou de r talonnage du mat riel D ballage R emballage L ensemble du mat riel a t v rifi m caniquement et lectriquement avant l exp dition Toutes les pr cautions ont t prises pour que l instrument parvienne sans dommage a l utilisateur Toutefois il est prudent de proc der une v rification rapide pour d tecter toute d t rioration ventuelle pouvant avoir t occasionn e lors du transport S il en est ainsi faire imm diatement les r serves d usage aupr s du transporteur GX 1010 d Attention E Remarque GX 1010 Dans le cas d une r exp dition du mat riel utiliser de pr f rence l emballage d origine et indiquer le plus clairement possible par une note jointe au mat riel les motifs du renvoi Les produits METRIX sont brevet s FRANCE et ETRANGER Les logotypes METRIX sont d pos s METRIX se r serve le droit de modifier caract ristiques et prix dans le cadre d volutions technologiques qui l exigeraient 2 1 2 2 2 3 2 4 2 5 DESCRIPTION GENERALE Ce g n rateur de fonctions programmable utilise la synth se num rique directe pour fournir des moyens tendus et tr s performants un prix tr s concurrentiel Il peut g n rer une gamme de signaux entre 0 1mHz et 10MHz avec une r solution de 7 digits et une pr cision sup rieure 10 ppm Synth se
62. te S lectionnez EXT VCA sur le menu AM et activez AM le niveau DC sera maintenant modul par le signal appliqu a la borne VCA IN Modulation de fr quence FSK La fonction FSK permet une commutation rapide de phase continue entre deux fr quences Tous les autres param tres du signal amplitude offset sym trie restent les m mes quand la fr quence est commut e pour une commutation entre signaux ou tous les param tres peuvent changer se r f rer HOP FSK peut tre contr l soit par le g n rateur d clenchement interne une entr e d clenchement externe par la touche MAN SYNC du panneau avant ou une t l commande Le mode FSK est activ et d sactiv par pressions altern es de la touche FSK la DEL c t de la touche s allume quand elle est activ e Les param tres sont tous r gl s du menu FSK qui est choisi en pressant EDIT puis FSK Quand FSK est choisi la DEL c t de FSK clignote pour montrer que la fonction est dit e sans regard et si le mode FSK est activ ou d sactiv FREQ A 10 00000kHz FREQ B 10 00000MHz SOURCE EXT TGEN 1 00ms 1 000kHz 4 6 1 R glage de fr quence Les deux fr quences FREQ A et FREQ B entre lesquelles le signal est commut sont r gl es exactement de la m me fa on que la fr quence dans le menu principal en fait FREQ A est la fr quence du g n rateur principal en mode non FSK et changer FREQ A dans le menu FSK changera aussi la fr quence d
63. to non volatile RAM using the ARB edit menu With the edit cursor in the first edit field of the menu alternate presses of the DIGIT keys will switch the field between RECALL and STORE STORE ARB NO O1 CONFIRM TO EXECUTE Pressing CONFIRM changes the menu to permit a name to be entered for the waveform Turning the rotary control scrolls through all available characters in the selected digit position the DIGIT keys are used to move the cursor to each digit position in turn SAVE ARB TO STORE 01 NAME USE DIGIT DIAL WAVE _ CONFIRM TO EXECUTE The display above shows the name WAVE entered when the name is complete pressing CONFIRM saves the waveform and name in the specified store A confirmation beep is given and the display returns the menu to RECALL ARB No nn when nn is the store number just saved 4 7 3 Noise The generator can be set to output pseudo random noise within the bandwidth 03Hz to 700kHz To achieve this bandwidth a simple RC filter is always switched in instead of the standard 7 stage filter whatever the FILTER setting is on the Options menu see Waveform Generation Options section Amplitude and offset are adjustable and Noise can be used in GATE and AM modes GX1010 Il 31 4 8 32 Il Noise is selected from the Noise menu accessed by pressing the blue EDIT key followed by NOISE the shifted function of 4 Noise is turned on and off with alternate presses of the DIGIT keys or by turnin
64. utilis s afin de traiter chaque choix la DEL correspondante cot des touches FUNCTION s allume afin de confirmer la s lection Les formes de signaux charg s STAIRcase et ARBitrary sont aussi incluses dans la s quence de s lection entre RAMP et SINE et leurs DEL s allument aussi quand elles sont s lectionn es Tous les param tres peuvent tre copi s d un chelon l autre Il suffit d entrer le nouvel chelon dans le champ n puis en appuyant sur RECALL les diff rences du nouvel chelon peuvent tre entr es comme il est d crit ci dessus Ceci permet de cr er rapidement de nouveaux chelons lorsque seulement un ou deux des param tres changent 4 8 2 D finir la S quence et la dur e Les 16 chelons contiennent toujours un r glage m me si celui ci est seulement le r glage par d faut Quand elle est r gl e pour fonctionner la s quence HOP d butera a l chelon 00 et ex cutera les chelons dans l ordre chronologique jusqu au num ro d chelon d fini dans le champ LAST ll recommencera alors l chelon 00 la s quence d sir e doit donc tre r gl e de fa on d buter l chelon 00 et le champ LAST doit tre r gl au dernier num ro d chelon valide Le contr le de mode interne externe ou manuel ou distance et la dur e interne si elle est s lectionn e sont r gl s avec le curseur dans le champ le plus droite de la premi re ligne de l afficheur le dessin montre les r
65. 0 le signal carr AUX OUT suit MAIN OUT de 90 Quand la phase est n gative AUX OUT m ne MAIN OUT La phase est r gl e en pressant la touche EDIT suivie de TRIG pour choisir le menu d clenchement d placez le curseur vers PHASE avec les touches FIELD La PHASE peut tre entr e directement du clavier ou par la molette on peut changer le signe en utilisant si n cessaire Au dessus de 30kHz AUX OUT accompagnant les signaux sinus triangle carr et impulsions est automatiquement commut de telle mani re qu elle est d riv du comparateur pilot par le signal sinus DDS utilis pour g n rer des signaux carr es et impulsions de plus haute fr quence sur MAIN OUT voir la section principes DDS pour de plus amples informations Ceci assure un signal AUX OUT sans vacillement jusqu la fr quence maximum du g n rateur mais signifie que l cart de phase entre MAIN OUT et AUX OUT n est pas possible Cependant cette contrainte peut tre limin e en changeant le r glage du menu OPTions AUX OUTPUT AUTO devient AUX OUTPUT LOW FREQ le signal AUX OUT continu ainsi d tre g n r ind pendamment avec phase ajustable et respect de la sortie MAIN bien que l instabilit d un cycle 86ns deviendra de plus en plus signifiant plus haute fr quence Changer les r glages AUTO est d crit plus amplement dans la prochaine section Options de g n rateur du signal Le signal AUX OUT acc
66. 0 lt version gt lt rmt gt lt NAME gt est le nom du constructeur lt model gt d finit le type d instrument et lt version gt est le niveau de r vision du logiciel install TST Le g n rateur ne dispose pas de capacit d essais automatique et la r ponse est toujours O lt rmt gt 5 2 13 Commande de v rouillage de phase TRG Ex cute un d clenchement qui aura le m me effet que d appuyer sur la touche MAN SYNC La commande Group Execute Trigger GET remplira la m me fonction que TRG CLOCKBNC lt cpd gt R gle le mode horloge bnc sur lt OUTPUT gt lt INPUT gt ou lt SLAVE gt ABORT Avorte dans le cas o une op ration de verrouillage de phase n aurait pas fonctionn normalement Si aucune op ration n tait en cours la commande n est pas prise en compte Si l op ration est avort e alors l erreur 136 est plac e dans le registre d ex cution d erreurs 5 3 R sum de commandes distance ESE lt nrf gt R gle le Standard Event Status Enable Register la valeur de lt nrf gt ESE Renvoie la valeur dans le standard Event Status Enable Register sous le format num rique lt nr1 gt ESR Renvoie la valeur dans le standard Event Status Register sous le format num rique lt nr1 gt IDN Renvoie l identification de l instrument IST Renvoie le message locale ist comme il a t d fini par IEEE Std 488 2 LRN Renvoie l installation compl te de l instrument sous la forme d un
67. 0 kHz Signal Range 2 5V for 100 level change at maximum output Input Impedance typically 6kQ 7 2 1 7 PHASE LOCKING The signals from these sockets are used to phase lock two or more generators e Clock In Out TTL CMOS threshold level as an input Output logic levels nominally 1V and 4V from typically 500 as an output e Sync Out TTL CMOS logic levels from typically 500 7 2 1 8 INTERFACES Full remote control facilities are available through the RS232 standard or optional GPIB interfaces RS232 Variable Baud rate 9600 Baud maximum 9 pin D connector GX1010 Il 63 7 3 64 Il IEEE 488 Conforming with IEEE488 1 and IEEE488 2 7 2 2 Safety IEC 1010 1 NFC 42020 1993 Degree of pollution 1 Indoor use altitude lt 2000m Installation category of inputs CAT 10V max Installation category of power supply CAT II 264V max Insulation class 1 7 2 3 General information Dimensions 3U 130mm height half rack 212mm width 330mm long Weight 4 1kg 9lb Power 230 115V or 100V nominal 50 60Hz adjustable internally operating range 14 of nominal 30VA max Installation category Il Environment 7 3 1 Temperatures Reference temperature Range of use 5 C to 40 C Storage range 20 C to 60 C Relative humidity 20 80 RH Fuse protection the correct mains fuse type are for 230V operation 250mA T 250V HRC for 100V or 115V operation 500mA T 250V H
68. 05Hz Les entr es de p riode du g n rateur qui ne peuvent tre r gl es exactement sont accept es et arrondies la valeur sup rieure La sortie g n rateur est disponible pour un signal niveau TTL la borne TRIG SWEEP OUT du panneau arri re En salve g n ralement le front montant de chaque cycle du g n rateur d clenchement est utilis e pour initier une salve l intervalle entre salve BURST est ainsi de 0 02ms 200s d termin par la p riode du g n rateur En mode Porte GATE la sortie du g n rateur principal est ouverte pendant que la sortie du g n rateur d clenchement est haute la dur e de la porte est ainsi de 01ms 100s en chelons avec les p riodes du g n rateur d clenchement de 0 02ms 200s 4 4 2 Entr e de d clenchement externe Les signaux porte ou de d clenchement externes sont appliqu s l entr e EXT TRIG du panneau avant qui a un seuil de niveau TTL 1 5V En mode salve d clench l entr e est d clenchement sur front Le front montant de chaque d clenchement externe initie la salve sp cifi En mode Porte l entr e est a niveau sensible la sortie du g n rateur principal est activ e pendant que le signal porte est haut gt 1 5V La largeur de impulsion minimale qui peut tre utilis e avec l entr e EXT TRIG est 50ns et la vitesse de r p tition maximale est 1Mhz Le signal maximal qui peut tre appliqu sans dommages est 10V 4 4 3 Salve d
69. 0ms a 999s r solution 3 digits Marqueurs Deux variant durant le balayage Disponible a la borne TRIG SWEEP OUT du panneau arri re Source de d clenchement de Le balayage peut tre lanc librement ou d clench des balayage sources suivantes du clavier interne externe a partir de l entr e EXT TRIG ou d une interface a distance e Modulation d amplitude Fr quence porteuse De 0 1mHz a 10 MHz Formes des signaux porteurs toutes profondeur Variable 0 100 r solution 1 source interne Signal sinus fix e 1 kHz ou signal carr e 0 005 Hz 50 kHz Externe Voir VCA e Modulation de fr quence FSK Commutation de phase coh rente entre deux fr quences choisies a une vitesse d finie par le signal source de commutation Fr quence porteuse De 0 1mHz a 10 MHz Formes de signal porteur Toutes Vitesse de r p tition 0 50 kHz interne 0 1 MHz externe Commutation du signal source au clavier ou par g n rateur d clenchement interne Externe partir de l entr e EXT TRIG ou d une interface distance e Phase Start Stop Fr quence porteuse 0 1 mHz au moins 1MHz Formes de signal porteuse toutes Gamme 360 360 degr s R solution 1 degr Pr cision 1 degr 30 kHz e G n rateur d clenchement GX 1010 1 65 66 Signal carr de 0 005 Hz a 50 kHz en source interne ajustable en pas de 20us R solution 3 digits Disponible pour usage externe a partir
70. 123456789 MLE AN INSTRUMENT Y Y ON THE CHAIN TX RX TXIN RXOUT All instruments on the interface must be set to the same baud rate and all must be powered on otherwise instruments further down the daisy chain will not receive any data or commands The ARC standard for the other interface parameters is as follows Start bits 1 Data bits 8 Parity None Stop bits 1 In this instrument as with most other ARC instruments these parameters are fixed 5 1 2 2 ARC Character Set Because of the need for XON XOFF handshake it is possible to send ASCII coded data only binary blocks are not allowed Bit 7 of ASCII codes is ignored i e assumed to be low No distinction is made between upper and lower case characters in command mnemonics and they may be freely mixed The ASCII codes below 20H space are reserved for interface control GX1010 5 1 2 3 ARC Interface Control Codes All instruments intended for use on the ARC bus use the following set of interface control codes Codes between OOH and 1FH which are not listed here as having a particular meaning are reserved for future use and will be ignored Mixing interface control codes inside instrument commands is not allowed except as stated below for CR and LF codes and XON and XOFF codes When an instrument is first powered on it will automatically enter the Non Addressable mode In this mode the instrument is not addressable and will not respond to any address commands This allows t
71. 5 2 3 Param tres de balayage SWEEP lt cpd gt SWPBEGFRQ SWPBEGPER SWPENDFRQ SWPENDPER SWPMKRFRQ SWPMKRPER lt nrf gt lt nrf gt lt nrf gt lt nrf gt lt nrf gt lt nrf gt SWPMODE lt cpd gt SWPLAW lt cpd gt SWPTIME lt nrf gt SWPSRC lt cpd gt TRG Fixe le mode de balayage sur lt ON gt ou lt OFF gt Fixe la fr quence de d but de balayage lt nrf gt Hz Fixe la p riode de d but de balayage lt nrf gt secondes Fixe le balayage et la fr quence lt nrf gt Hz Fixe la p riode de balayage de fin lt nrf gt secondes Fixe la fr quence du marqueur de balayage lt nrf gt Hz Fixe la p riode du marqueur de balayage lt nrf gt secondes Fixe le mode de balayage sur lt BTOE gt d but a fin ou lt ETOB gt fin a d but Fixe la loi de balayage a lt LOG gt ou lt LIN gt Fixe le temps de balayage a lt nrf gt secondes Regle la source de balayage sur lt CONT gt continu lt EXT gt exterieur ou lt MAN gt manuel Provoque un d clenchement ayant le m me effet que d appuyer sur la touche MAN SYNC La source de d clenchement MAN REMOTE doit tre s lectionn e en premier La commande Group Execute Trigger GET remplit la m me fonction que TRG 5 2 4 D clenchements et Portes TRIG lt cpd gt GATE lt cpd gt TRIGSRC lt cpd gt GATE SRC lt cpd gt 48 R gle le mode de d clenchement sur lt ON gt ou lt OFF gt R gle le mode de port
72. C 20 80 RH non condensing It may occasionally be subjected to temperatures between 5 and 10 C without degradation of its safety 1 1 2 During use Use of this instrument in a manner not specified by these instructions may impair the safety protection provided Do not operate the instrument outside its rated supply voltages or environmental range In particular excessive moisture may impair safety WARNING THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous Intentional interruption is prohibited The protective action must not be negated by the use of an extension cord without a protective conductor When the instrument is connected to its supply terminals may be live and opening the covers or removal of parts except those to which access can be gained by hand is likely to expose live parts The apparatus shall be disconnected from all voltage sources before it is opened for any adjustment replacement maintenance or repair If the instrument is clearly defective has been subject to mechanical damage excessive moisture or chemical corrosion the safety protection may be impaired and the apparatus should be withdrawn from use and returned for checking and repair Make sure that only fuses with the required rated current and of the specified type are used for replacement The use of makeshift fuses and the short circuiting of fuse hol
73. C accuracy and 0 5 AC accuracy at 1kHz e Frequency counter capable of measuring 10 00000MHz and 50us 0 1us pulsewidths The DVM is connected to the MAIN OUT and the counter to the AUX OUT Frequency meter accuracy will determine the accuracy of the generator s clock setting and should ideally be 1ppm It may be quicker to use an oscilloscope for steps 05 and 15 see next section 3 3 2 Calibration Procedure The CALibration procedure is accessed by pressing the blue EDIT key followed by CAL the shifted function of 6 At each step the display changes to prompt the user to adjust the rotary control or FIELD DIGIT keys until the reading on the specified instrument is at the value given The FIELD keys provide very coarse adjustment the DIGIT keys coarse adjustment and the rotary control fine adjustment Pressing CONFIRM increments the procedure to the next step pressing CE decrements back to the previous step Alternatively pressing ESCAPE exits to the last CAL display at which the user can choose to either keep the new calibration values CONFIRM return to the old values ESCAPE or restart the calibration procedure CE The first two displays CAL 00 and CAL 01 specify the connections and adjustment method The subsequent displays CAL 02 to CAL 20 permit all adjustable parameters to be calibrated The full procedure is as follows CAL02 Zero DC Offset Adjust for OV 5mV CAL 03 DC Offset ve full scale Adjust for 10V 20mV
74. CUMUG Les diaere eegene A 67 723s IMOMMAUONS GENE GIES none ere ie ee dianas 67 7 3 leie EE 67 Fe Oude Temperatures A En tete 67 FCK er EE 67 TACA es Re nn A tilts eaten nn Ps 68 7 0 ACCOSSGIIES Ct OPTIONS pios 68 Te ACCESS EE 68 ANNEXE 1 Messages d erreur et d alerte 69 ANNEXE 2 R glages usine par d faut 71 GX 1010 1 INSTRUCTIONS GENERALES Ce g n rateur de fonctions est un instrument de Classe en s curit selon la classification CEI et il a t concu pour satisfaire aux imp ratifs de la norme CEI 1010 1 imp ratifs de s curit pour les appareils lectriques de mesure utilisation de contrdle et de laboratoire C est un instrument d installation cat gorie Il destin a une utilisation a partir d une alimentation monophas e 1 1 Pr cautions et mesures de s curit 1 1 1 Avant utilisation Cet instrument a t soumis des essais conform ment la norme CEI 1010 1 et il a t fourni de mani re ne pr senter aucun danger Ce manuel d instructions contient des informations et des avertissements que l utilisateur doit suivre pour garantir une exploitation imm diate et longue ch ance de toute s curit Cet instrument a t construit pour pouvoir tre utilis l int rieur dans un environnement Degr de pollution 1 c d sans pollution ou uniquement pollution s che non conductrice dans une gamme de temp ratures de 5 C a40 humidit relative 20 80 sans condensation
75. D AND CLEAR QUERY ERROR ERROR NUMBER IN QUERY ERROR REGISTER QER READ AND CLEAR OPERATION COMPLETE y STANDARD EVENT STATUS REGISTER ESR READ AND CLEAR STANDARD EVENT STATUS ENABLE REGISTER ESE lt NRF gt SET TO lt NRF gt ESE READ STATUS BYTE REGISTER SERIAL POLL READ WITH RQS STB READ WITH MSS SERVICE REQUEST ENABLE REGISTER SRE lt NRF gt SET TO lt NRF gt SRE READ 5 1 6 Formats de commande a distance ARC L entr e s rie l instrument est s par e dans une file d attente d entr e de 256 octets qui est remplie sous interruption d une mani re transparente pour toutes les autres op rations d instrument L instrument transmettra XOFF lorsque 200 caract res environ se trouvent dans la file d attente et XON lorsque 100 espaces libres environ sont disponibles dans la file d attente apr s la transmission de XOFF Cette file d attente contient des donn es pures syntaxe non analys e prises par l analyseur de syntaxe selon les GX 1010 45 46 besoins Les commandes et interrogations sont ex cut es dans l ordre et l analyseur de syntaxe ne commence pas de nouvelle commande avant qu une commande ou interrogation pr c dente soit effectu e ll n y a pas de file d attente de sortie ce qui veut dire que la mise en forme de r ponse attend ind finiment le cas ch ant que l instrument soit adress sur parole et que le message de r ponse complet ait t transmis
76. E Std 488 2 1987 Sous groupes GPIB 5 1 3 1 Sous groupes GIPB L instrument contient les sous groupes IEEE 488 1 suivants Source Handshake SH1 Acceptor Handshake AH Talker T6 Listener L4 Service Request SR1 Remote Local RL1 Parallel Poll PP1 Device Clear DC1 Device Trigger DT1 Controller CO Electrical Interface E2 5 1 3 2 Gestion d erreur GPIB IEEEStd 488 2 L erreur UNTERMINATED IEEE 488 2 adress pour mettre en n ayant rien a mettre est g r e de la mani re suivante Si l instrument est adress sur mission et que la mise en forme de r ponse est inactive et que la file d attente d entr e est vide l erreur UNTERMINATED se produit alors Ceci entra ne le r glage du bit Query Error dans le Standard Event Status Register et 3 est plac dans le Query Error Register et l analyseur syntaxique est r initialis Voir la section registre d tat pour plus d informations a cet effet L erreur INTERRUPTED IEEE 488 2 est g r e de la mani re suivante Si la mise en forme de r ponse attend de transmettre un message de r ponse et qu un lt PROGRAM MESSAGE TERMINATOR gt a t lu par l analyseur syntaxique ou que la file d attente d entr e contient plus d un message END l instrument est alors INTERRUPTED et une erreur se produit Ceci entra ne le r glage du bit Query Error dans le Standard Event Status Register 1 est plac dans le Query Error Register et le formatage de r ponse doit tre r initialis pour d gage
77. E lt nrf gt PRE SRE lt nrf gt SRE STB WAI GX 1010 valable de 1 9 Renvoie les r glages complets de l instrument sous la forme d un bloc de donn es de caract res hexad cimaux longueur d environ 842 octets Pour r installer les r glages renvoyer le bloc l instrument exactement comme il a t re u La syntaxe de la r ponse est LRN lt Caract re donn es gt lt rmt gt Les r glages de l instrument ne sont pas affect s par l ex cution de la commande LRN installe des donn es pour une commande LRN S informe et efface le registre des num ros d erreurs d ex cution Le format de r ponse est nr1 lt rmt gt S informe et efface le registre des num ros d erreurs Le format de r ponse est nr1 lt rmt gt Clear status D gage les registres Standard Event Status Register Query Error Register et Execution Error Register Ceci r initialise indirectement le registre Status Byte Register Fixe le Standard Event Status Enable Register a la valeur de lt nrf gt Renvoie la valeur du Standard Event Status Enable Register sous format num rique lt nr1 gt Syntaxe de la r ponse lt nri gt lt rmt gt Renvoie la valeur du Standard Event Status Enable Register sous format num rique lt nr1 gt Le registre est maintenant r initialis Syntaxe de la r ponse lt nr1 gt lt rmt gt Renvoie le message local ist d fini par la norme IEEE Std 488 2 La syntaxe de la r ponse est O lt rmt gt
78. E gt is defined as character codes OOH to 20H inclusive with the exception of the codes specified as ARC interface commands The high bit of all characters is ignored The commands are case insensitive 5 1 7 GPIB remote command formats GPIB input to the instrument is buffered in a 256 byte input queue which is filled under interrupt in a manner transparent to all other instrument operations The queue contains raw un parsed data which is taken by the parser as required Commands and queries are executed in order and the parser will not start a new command until any previous command or query is complete There is no output queue which means that the response formatter will wait indefinitely if necessary until the instrument is addressed to talk and the complete response message has been sent before the parser is allowed to start the next command in the input queue Commands are sent as lt PROGRAM MESSAGES by the controller each message consists of zero of more lt PROGRAM MESSAGE UNIT gt elements separated by lt PROGRAM MESSAGE UNIT SEPARATOR gt elements lt PROGRAM MESSAGES gt are separated by lt PROGRAM MESSAGE TERMINATOR gt elements which may be any of the following NL The new line character OAH NLAEND The new line character with the END message SEND The END message with the last character of the message A PROGRAM MESSAGE UNIT SEPARATOR gt is the semi colon character BH A lt PROGRAM MESSAGE UNIT gt
79. EN la seconde ligne du menu dit Avec le curseur dans la zone num rique les touches DIGIT d placeront le curseur l int rieur de la zone et la molette changera la valeur selon la position du curseur avec le curseur dans les zones unit les touches DIGIT ou la molette changeront la valeur par dizaine Les entr es directes par clavier seront accept es GX 1010 25 26 o que soit le curseur A c t de la p riode g n rateur se trouve l quivalent fr quence uniquement pour information Du fait que le g n rateur d clenchement interne peut tre utilis par les fonctions trigger Porte GATE FSK et AM Modulation d amplitude et peut tre r gl de leurs menu respectifs une zone d information est affich e entre parenth ses c t de TGEN quand celui ci est choisi comme source Cette zone affichera FREE quand TGEN n est pas utilis autre part une des lettres G F A T pour indiquer que le g n rateur est d sormais r gl comme source sur le menu PORTE GATE FSK AM ou TRIG en plus du menu affich 4 4 3 2 Compteur de Salve Le nombre de cycles complets dans chaque salve suivant le d clenchement est r gl avec le curseur dans la zone BURST COUNT Les entr es peuvent tre faites directement du clavier ou de la molette la gamme de salve va de 1 1023 avec une r solution d un cycle de 0 5 511 5 avec une r solution de 0 5 cycle Le premier cycle est lanc et le dernier cycle st
80. ET n est pas z ro le signal est invers pour l offset Il y a une exception si le niveau de sortie est en dBm si les signaux bas sont sp cifi s dBm le signe signifie une partie d une entr e d un nouveau signal et non une commande pour inverser le signal Le niveau sortie doit tre montr comme une valeur EMF ou PD pour la touche pour fonctionner comme une touche inversion signal Si un changement d amplitude implique une commutation de l att nuateur la sortie est inactive pendant 45 ms pendant que le changement s effectue pour pr venir l apparition de transitoires a la sortie 4 2 1 3 Imp dance de sortie L imp dance de la sortie MAIN OUT est s lectionn dans la derni re zone de la seconde ligne bouger le curseur vers cette zone et utiliser les touches DIGIT ou la molette pour passer de 50Q a 6000 Le niveau de sortie est inchang mais la valeur en dBm changera car la r f rence 0dBm 1mW dans l imp dance sp cifi e change avec l imp dance 4 2 1 4 Decalage continu DC OFFSET L offset DC est r gl la troisi me ligne du menu principal Le curseur n importe o sur la troisi me ligne l offset DC peut tre chang directement du clavier en entrant le nombre et l unit appropri e ex 100mv entrer 1 0 0 mV ou or 1 V etc Si le curseur n est pas sur la troisi me ligne il faut d abord presser la touche DC OFFSET pour placer le curseur avant GX 1010 1 15 l 16 de taper
81. GATE et modulation d amplitude AM 7 2 1 4 MODES MODULATION e D clenchement Salves Manipulation de signal a phase coh rente Chaque front positif du signal d clencheur produira une salve de la porteuse d marrant et s arr tant l angle de phase sp cifi par le r glage de phase Start Stop Fr quence porteuse 0 1mHz au moins 1MHz Formes de signal porteur Toutes Nombre de cycles 1 1023 r solution 1 cycle ou 0 5 511 5 r solution 0 5 cycle vitesse de d clenchement 0 50 kHz interne 0 1MHz externe GX 1010 Source Interne du clavier ou du g n rateur a d clenchement Externe a partir de l entr e EXT TRIG ou d une interface a distance e Porte Gated Manipulation de signal a phase non coh rente signal porteur de sortie active quand le signal Porte GATE est haut et passive quand il est bas Fr quence porteuse de 0 1 mHz a 10 MHz Formes de signal porteur toutes vitesse de rep d clenchement 0 50 kHz interne O 1 MHz externe Source de signal Porte Interne du clavier ou du g n rateur a d clenchement Externe partir de l entr e EXT TRIG ou d une interface distance e Balayage Formes de signaux porteurs Toutes Mode balayage Lin aire ou logarithmique simple ou continu Largeur de balayage De 0 1 mHz a 10 MHz dans une gamme Phase continue R glage ind pendant de la fr quence de d part start et d arr t stop P riode de balayage 1
82. GEN doit tre son r glage par d faut de 1 00ms 1 000kHz et le d compte du salve doit tre fix 0001 Le r glage par d faut de la phase de 0 correspond au sommet du front montant de l impulsion et a partir de cette phase ne donnera pas le r sultat d sir r glez la phase sur 90 en d pla ant le curseur vers le champ PHASE avec les touches FIELD et entrez 9 0 CONFIRM Pendant que vous tes toujours dans le menu Trigger appuyez sur TRIG une nouvelle fois afin d activer le mode Trigger D clenchement gt MAIN PER SYM i e PERIODE TGEN ______________ y Un seul cycle du g n rateur principal donc une seule impulsion sera maintenant en sortie la fr quence par d faut de 1 kHz un rapport cyclique de 1000 1 a t achev D placez le curseur vers le champ de p riode TGEN avec les touches FIELD et augmentez la p riode en utilisant le commutateur bien qu il soit difficile de la d tecter sur l oscilloscope la largeur de l impulsion 1 us est maintenue des r gimes de r p tition en mHz donc un rapport cyclique tr s petit Notez que pour les fr quences du g n rateur principal situ es au dessus de 30kHz le contr le de phase des signaux d impulsion est limit moins que la g n ration de forme de signaux soit en mode Basse Fr quence se reporter la section g n rateur de GX 1010 6 4 signaux ceci montre a quel point une impulsion peut tre g
83. GX1010 GENERATEUR DE FONCTION PROGRAMMABLE 10 MHZ A SYNTHESE NUMERIQUE PROGRAMMABLE 10 MHZ DDS GENERATOR FUNCTION NOTICE DE FONCTIONNEMENT CHAPITRE OPERATING MANUAL CHAPTER Il Copyright melrix GX 1010 GX1010 GENERATEUR DE FONCTION PROGRAMMABLE 10 MHZ A SYNTHESE NUMERIQUE NOTICE DE FONCTIONNEMENT CHAPITRE GX 1010 GX 1010 T INSTRUCTIONS e TR 1 1 1 Pr cautions et mesures de s curit ss 1 1 1 1 Avant AISA EE 1 Tale PONG AT NI UE 1 E E OV MD ES tac tena ected eee is ls Bo ke a ete ean eee 2 ed A e e LEE 2 Tr CANIN Re ee oa RN oe MRL PEPER te 2 1 3 D ballage R emballage EE 2 e le Ke TR 4 2 1 Synth se num rique directe pour la pr cision et la Stabilit ce eee eeeeeeeeeeeeeeeeeeeeeeeeees 4 2 2 Une large gamme de formes de signaux 4 SNE REIR A Ta Ac cs D nr cn sn 4 2A AMi RS aaae e A A GE dete 4 DOD Mol seat van ee o de dune 4 2 6 D clenchement par salve ou mode porte GATE 5 2 7 AMES NU A A o EEEE EESe errre Ennn enet 5 2 8 G n rateurs v rouillage de phase multiple EEN 5 2 9 Utilisati n Simple ees 5 2 10 Standard RS 232 adressable GPIp 5 3 PREPARATION EA LUTILISATION lt nnmnnn 6 3 1 Assemblage te eae EE 6 3 2 Tensioni d alimentatio icon on eg aul asad hud alone etui ladite dos 6 3 2 1 Alimentation partir du r seau Installation 0 0 0 0 ccc eeeeeeee eee eeeeeneeeeeeeeeeeeeeeeeeeeteeennaaees 6 e ee ee en vedic onsen Ro o 6 3 3 Mat riel AAA A A E 7
84. MAN SYNC key or by the appropriate commands via the RS232 or GPIB interfaces With the source set to TGEN the generator waveform is gated on as explained in the Internal Trigger Generator section the trigger generator is set exactly as described in the Trigger Source section Amplitude Modulation Two modes of operation are available from the AM menu e Amplitude Modulation using the Internal Trigger Generator as the modulation source in which the modulation depth is expressed as a percentage and constant modulation depth is maintained as the main generator carrier amplitude is varied e VCA Voltage Controlled Amplitude mode in which the main generator amplitude is directly proportional to the external modulating signal voltage applied to the rear panel VCA IN socket Suppressed carrier modulation SCM is achievable in this mode AM mode is turned on and off with alternate presses of the AM key the lamp beside the key lights when AM mode is on The AM parameters are all set from the AM edit menu which is selected by pressing the blue EDIT key followed by the AM key When AM edit is selected the lamp beside the AM key flashes to show edit mode regardless of whether AM mode is currently selected to be on or off SOURCE EXT VCA TGEN 1 00ms 1 000kHz INT MOD DEPTH 030 INT MOD SQUARE 4 5 1 Amplitude Modulation Internal With the edit cursor in the SOURCE field of the AM edit menu the DIGIT keys or rotary control can be used to t
85. N PRE lt nrf gt PRE RCL lt nrf gt RST SAV lt nrf gt SRE lt nrf gt SRE STB Set the Standard Event Status Enable Register to the value of lt nrf gt Returns the value in the Standard Event Status Enable Register in lt nr1 gt numeric format Returns the value in the Standard Event Status Register in lt nr1 gt numeric format Returns the instrument identification Returns ist local message as defined by IEEE Std 488 2 Returns the complete set up of the instrument as a hexadecimal character data block approximately 842 bytes long Set the Parallel Poll Enable Register to the value lt nrf gt Returns the value in the Parallel Poll Enable Register in lt nr1 gt numeric format Recalls the instrument set up contained in store number lt nrf gt Resets the instrument parameters to their default values Saves the complete instrument set up in the store number lt nrf gt Set the Service Request Enable Register to lt nrf gt If the value of lt nrf gt Returns the value of the Service Request Enable Register in lt nr1 gt numeric format Returns the value of the Status Byte Register in lt nr1 gt numeric format GX1010 TRG TST WAI ABORT AM lt cpd gt AMDEPTH lt nrf gt AMSRC lt cpd gt AMWAVE lt cpd gt ARB ARB ARB ARBRCLe lt nrf gt ARBSAV lt nrf gt lt cpd gt AUX lt cpd gt BCNT lt nrf gt BEEP BEEPMODE lt cpd gt CLOCKBNC lt cpd gt
86. NC PRINC xSYM gt gt x SYM lt _ PERIODE TGEN p4 PERIODE TGEN ____ R glez le g n rateur principal sur 10 kHz 10Vpp en appuyant sur FREQ 1 0 kHz et EMF 1 0 V changez la sym trie 60 40 en appuyant sur SYM 6 0 DC OFFSET 0 V s lectionnez TRIANGLE GX 1010 57 58 S lectionnez le menu Trigger en appuyant sur EDIT TRIG et fixez SOURCE TGEN g n rateur de d clenchement interne R glez la p riode TGEN sur 1ms 1 000kHz le BURST COUNT sur 000 5 et la PHASE sur 90 S il est teint allumez le mode Trigger en appuyant une nouvelle fois sur TRIG La forme du signal doit tre telle qu elle est sur le diagramme Les temps de mont e et de descente peuvent tre r duits en augmentant la frequence du g n rateur principal et la relation entre les temps de mont e et de descente peut tre modifi e en changeant la sym trie 6 4 2 Impulsions Bande limit e Les fronts des impulsions bande limit e sont des segments des signaux sinuso daux commen ant partir de 90 Normalement les temps de mont e et de descente seront les m mes donc le g n rateur principal est r gl 50 Pour poursuivre l exemple pr c dent Fixez SYM 5 0 S lectionnez SINE Si les param tres de d clenchement ont t chang s depuis le dernier exemple entrez les nouveau PER PRINC PER gert PRINC gt xsym 4 PERIODE TGEN _ gt
87. OCK BNC OUTPUT the default setting a buffered version of the internal clock is made available at the CLOCK IN OUT socket When two or more generators are synchronised the master is set to OUTPUT and the signal is used to drive the CLOCK IN OUT of slaves With CLOCK BNC INPUT the socket becomes an input for an external clock With CLOCK BNC PHASE LOCK the generator is in slave mode and CLOCK IN OUT socket must be driven by a master generator set to CLOCK BNC OUTPUT Because setting slave mode cancels any gate trigger sweep or FSK mode currently running a warning message is shown when this option is selected and it is necessary to press CONFIRM to execute pressing ESCAPE will return the setting to INPUT or OUTPUT Further details are given in the Synchronising Generators section Synchronising Generators Two or more generators can be synchronised together following the procedure outlined below the number of generators that can be linked in this way will depend on the clocking arrangement cable lengths etc but problems should not be experienced with up to 4 generators 4 10 1 Synchronising Principles Frequency locking is achieved by using the clock output from the master generator to drive the clock inputs of slaves The additional connection of an initialising SYNC signal permits each slave to be synchronised such that the phase relationship between master and slave outputs is that
88. RAMP TIME 0 05 S TRIG SRC CONTINUOUS MORE gt gt gt Presser la touche gauche FIELD avec le curseur dans la premi re ligne MODE renverra le curseur la derni re zone de la premi re page du menu balayage presser la touche droite FIELD d placera le curseur travers toutes les zones jusqu TRIG SRC une pression suppl mentaire renvoie le curseur la premi re zone de la premi re page Presser ESCAPE pour sortir du menu dit pour le menu principal Avec le curseur dans la zone MODE des pressions altern es des touches DIGIT ou la rotation de la molette changeront la direction de balayage BEG END ou END BEG Il n y a pas de restrictions sur les fr quences BEG et END la fr quence BEG peut tre plus haute que la fr quence END la zone MODE vous fournira un moyen simple de changer la direction de balayage Avec le curseur dans la zone LAW le balayage peut tre chang de LiN aire LOGarithmique Avec le r glage LAW LIN la fr quence change lin airement avec la p riode travers le balayage avec LAW LOG la fr quence change de facon exponentielle avec la p riode a travers le balayage le terme log sweep est une convention avec la fr quence d part plus basse que la fr quence arr t le mode habituel de fonctionnement la relation math matique de fr quence au temps est en fait anti log La vitesse de balayage est r gl e avec le curseur dans la zone RAMP TIME le temps de rampe peut tre r gl
89. RC 7 3 2 E M C This function generator has been designed in conformity with EMC standards in use and the compability has been tested regarding the following standards IEC 1326 1 e Emissions Radiated and conducted IEC 1326 1 class A e Immunity Test methods and limits used were a IEC 1000 4 2 Electrostatic Discharge b IEC 1000 4 3 RF Field c IEC 1000 4 4 Fast Transient d IEC 1000 4 11 AC voltage interup GX1010 7 4 7 5 e Cautions To ensure continued compliance with the EMC directive the following precautions should be observed a connect the generator to other equipment using only high quality double screened cables b after opening the case for any reason ensure that all signal and ground connections are remade correctly before replacing the cover Always ensure all case screws are correctly refitted and tightened c In the event of part replacement becoming necessary only use components of an identical type see the Service Manual Storage To guarantee the measurements accuracy after a long period storage in extreme environment conditions it s recommended to take following precautions e Wait enough time for the instrument to acclimatise to the working environment conditions see environment specifications Accessories 7 5 1 Accessories 7 5 1 1 Supplied with instrument one power cord one user s manual GX1010 Il 65 66 Il ANNEXE 1 Warning and Error Messa
90. RIGger SouRCe field the options are CONTINUOUS EXTernal and MAN REMOTE In CONTINUOUS mode the sweep starts simultaneously with the high to low transition of the TRIG SWEEP OUT signal the sweep starts with the phase at 0 and at the output level set by the DC offset At the end of the sweep the signal returns to this DC offset level and the TRIG SWEEP OUT signal simultaneously goes high again After a delay long enough for an oscilloscope to retrace for example the cycle repeats In EXTernal mode a trigger signal is connected to the front panel EXT TRIG socket A sweep starts typically 200 800us after the rising edge of the trigger signal the sweep is completed before another trigger edge is recognised and a new sweep initiated The GX1010 Il 23 4 4 24 Il minimum trigger pulse width is 1ms and the repetition rate should be gt 1 1 x sweep time 5 ms In MAN REMOTE mode a single sweep is initiated by each press of the MAN SYNC key or by each remote command If the MAN SYNC key is pressed again during a slow sweep continuous or single sweep the sweep will be paused at the instantaneous sweep frequency until MAN SYNC is pressed again to allow the sweep to continue 4 3 5 Frequency Stepping Resolution The generator frequency is stepped not truly swept between the BEGin and END frequencies The number of discrete frequency steps in a sweep is determined by the ramp time selected on the sweep edit menu the size of each step
91. S e Main Output Output Impedance 509 or 6000 GX1010 Amplitude 5mV to 20V pk pk open circuit 2 5mV to 10V pk pk into 500 6000 Output can be specified as EMF open circuit value or P D potential difference in pk pk r m s or dBm Amplitude Accuracy typically 3 1mV at 1kHz into 509 6002 Amplitude Flatness 0 2dB to 200 kHz 1dB to 5 MHz 2 5dB to 10 MHz DC Offset Range 10V DC offset plus signal peak limited to 10V from 500 6000 DC Offset Accuracy typically 3 10mV unattenuated Resolution 3 digits or 1mV for both Amplitude and DC Offset Pulse Aberrations lt 5 2mV e Aux Out CMOS TTL levels with symmetry and frequency of main output and phase of Start Stop Phase setting e Trig Sweep Out Multifunction output depending upon mode Except in Sweep and HOP modes the output is that of the Trigger Generator at CMOS TTL levels from 1kQ In Sweep mode the output is a 3 level waveform changing from high 4V to low OV at start of sweep with narrow 1V pulses at each marker point In HOP mode the output goes low at the entry to each step followed by a rising edge after the frequency and waveshope have changed for the new step 7 2 1 6 INPUTS e Ext Trig Frequency Range DC 1 MHz Signal Range Threshold nominally TTL level maximum input 10V Minimum Pulse Width 50ns for Trigger Gate and FSK modes 1ms for Sweep and HOP modes Input Impedance 10kQ e VCA In Frequency Range DC 10
92. TING MANUAL Copyright TEIP DE GX1010 GX1010 CONTENTS 1 GENERAL INS TRUG det LE 1 1 1 Precautions and Safety measures io i 1 A A 1 AA BCEE 1 AO AMIDO LS ee eege ee ee eet 2 1 1 4 Safety instructions cae tk ae ts tae ies estrias cos as 2 12 AAA EE 2 1 3 APARECE esenea nenene 2 2 GENERAL DESCRIPTION cinco esi eee ee nee ieee ee 4 2 1 Direct digital synthesis for accuracy amp Stability c cece eee eceenee eter ee eeeeeeeeeeeeeeaeeeeeeeeestaaaes 4 2 2 A Wide range of wavefoiMS ene ieee a a E 4 237 OWED EE 4 E EE 4 CAS FOR OEE RA ee ROT UC POTS EE EE Pee OME ERE ET 4 26 Trader EE Sn eta atte 5 2 7 Waveform REENEN 5 2 8 Multiple phase locked generators cuina id 5 2 9 Easy and convenient to USO nia iaa 5 2 10 Addressable RS 232 standard GPIR 5 3 COMMISSION N G sss caste iaaa a each tr tn ia 6 3 SNS SIMO EE 6 D ee EE 6 ee TIA OWEN lee EE 6 EE E FE E Cea eat ur ne 6 3 3 1 Equipment Ee EE 7 3 3 2 Calibration Procedure EE 7 EE 8 4 FUNCTIONAL DESCRIPTION see iccociociiciciiiacois tocador iii 9 O E E EO AE EE 9 BA EEN lee 9 212 WC OMS En de A iaa 9 4 1 3 Display Contra Satriani rss cal arte 10 4 14 VO H 10 4 1 5 Principles of e TEE 11 GX1010 4 1 6 Front Panel Connechons AEN aarete EEA aAa 12 4 1 7 Rear Panel Connections acacia 12 4 2 BASIGUNCIIONS torta data 14 4 2 1 Main Generator Operation miii 14 4 2 2 Auxiliary Qutput e ace der dan cr at ta ebe 19 4 2 3 Waveform Generation
93. The function of the CLOCK IN OUT socket is set from the SYStem menu as follows INPUT The socket becomes an input for an external clock OUTPUT This is the default setting The internal clock is made available at the socket When two or more generators are synchronised the master is set to OUTPUT and the signal is used to drive the CLOCK IN inputs of the slaves PHASE LOCK When two or more generators are synchronised the slaves are set to PHASE LOCK As an output the logic levels are nominally 1V and 4V from typically 50Q CLOCK OUT will withstand a short circuit As an input the thresholds is TTL CMOS compatible Do not apply external voltages to this output exceeding 7 5 V or 2 5 V 4 1 7 2 VCAIN This is the input socket for external voltage controlled amplitude VCA Input impedance is nominally 6kQ Apply 2 5V for 100 level change at maximum output Do not apply external voltages exceeding 10V 4 1 7 3 SYNC OUT When two or more generators are synchronised the SYNC OUT socket on the master generator is connected to the EXT TRIG inputs of slave generators GX1010 SYNC OUT logic levels are nominally OV and 5V from typically 50Q SYNC OUT will withstand a short circuit A Do not apply external voltages to this output 4 1 7 4 TRIG SWEEP OUT The function of this output is automatically determined by the generator operating mode Except in sweep and HOP modes the output is that of the internal trigger generator
94. X 57 Hop 5 32 34 47 60 Interfaces 37 K Keyboard 10 Kale LF 58 LOW 20 M MAIN OUT 9 12 58 Markers 22 MODE 10 Modulation Depth 27 Modulation Frequency 27 Multi Level 60 N Noise 5 31 60 NUMERIC UNIT 10 O OUTPUT 10 12 14 15 19 21 52 61 Overshoot 55 p PHASE 5 49 58 62 POWER UP 35 42 Precautions 1 Pulse 52 53 60 RAM 9 Ramp 23 Recalling 34 REMOTE 37 45 49 Repackaging 2 Rotary 34 ROTARY CONTROL 11 RS 232 5 9 13 Running 33 Safety 1 2 63 Sequence 32 Service 2 8 SET 10 Setting 35 Set ups 36 Slew limited 54 Source 23 Squarewave 20 Stability 4 Staircase 29 47 Start 25 61 Status 42 48 Step 32 Storage 34 64 Sweep 4 13 21 22 23 46 58 61 Symbols 2 Symmetry 17 59 SYNC OUT 12 62 Synchronising 35 36 System 48 T Temperatures 63 TGEN 27 53 Timing 32 TRIG 13 19 21 24 25 27 29 46 60 61 62 Trigger 5 U Unpacking 2 V VCA 27 28 62 W Warning 17 Warranty 2 Waveform 4 20 28 31 47 56 58 59 GX1010
95. a fixed amplitude square wave whose frequency is set on the TRIG or GATE menus The rising edge of the trigger generator initiates trigger burst gate etc In sweep mode the output is a 3 level waveform changing from high 4V to low OV at start of sweep with narrow 1V pulses at each marker point In HOP mode the output goes low on entry to each waveform step and high after the new frequency and waveshape of that step have been set Output levels are nominally OV and 4V from 1kQ TRIG SWEEP OUT will withstand a short circuit A Do not apply external voltages to this output 4 1 7 5 RS 232 9 pin D connector compatible with ARC Addressable RS232 Chain system The pin connections are shows below Pin Name Description 1 No internal Connection 2 TXD Transmitted data from instrument 3 RXD Received data to instrument 4 No internal connection 5 GND Signal ground 6 No internal connection 7 RXD2 Secondary received data 8 TXD2 Secondary transmitted data 9 GND Signal ground Pin 2 3 and 5 may be used as a conventional RS232 interface with XON XOFF handshaking Pins 7 8 and 9 are additionally used when the instrument is connected to the ARC interface Signal grounds are connected to instrument ground The ARC address is set from the front panel using the I F menu 4 1 7 6 GPIB IEEE 488 The GPIB interface is an option It is not isolated the GPIB signal grounds are connected to the instrument ground The impleme
96. a sortie TRIG SWEEP OUT sort toujours le signal du g n rateur a d clenchement interne Notez que sauf en utilisant le g n rateur d clenchement interne en modes Trigger Porte GATE FSK ou AM le signal n est pas synchronis avec le g n rateur principal GX 1010 21 4 3 22 Fonctionnement en balayage sweep 4 3 1 G n ralit s Le fonctionnement DDS a l avantage sur les autres g n rateurs de donner des balayages phase continue sur des gammes tr s larges de fr quences jusqu 10 1 Cependant il faut se souvenir que la fr quence est en fait d coup e n est pas balay e d une fa on lin aire et un temps est n cessaire pour une grande combinaison du temps de balayage et de l envergure de fr quence voir section r solution de pas en fr quence Le mode balayage s active et se d sactive par pressions altern es sur la touche SWEEP il y a une DEL t moin c t de la touche Les param tres de balayage d but fin et fr quences marqueurs direction de balayage loi p riode de rampe et source sont tous r gl s du menu balayage SWEEP qui est s lectionn en pressant la touche bleue EDIT suivi de SWEEP Quand SWEEP est choisi la DEL t moin clignote indiff rente du fonctionnement de balayage choisi Les param tres du mode balayage sont r gl s sur deux pages de l affichage le curseur se d place dans et entre les pages avec les touches FIELD et DIGIT comme d crit dans la sect
97. al modes for the master and slaves are set in the CLOCK BNC field of the SYStem menu see System Settings section The master is set to CLOCK BNC OUTPUT and all the slaves are set to CLOCK BNC PHASE LOCK 4 10 4 Synchronising Having made the connections and set up the generators as described in the preceding paragraphs synchronisation is achieved by pressing the MAN SYNC key of each slave in turn Once synchronised only the clock connections need be maintained however any change to the set up of a slave e g a phase change will cause synchronisation to be lost as the waveform memory is rewritten with the new phase etc and re synchronisation will be necessary GX1010 REMOTE OPERATION Interfaces The following sections detail the operation of the instrument via both GPIB and ARC Where operation is identical no distinction is made between the two Where differences occur these are detailed in the appropriate sections or in some cases separate sections for GPIB and ARC It is therefore only necessary to read the general sections and those sections specific to the interface of interest At power on the instrument will be in the local state with the REMOTE lamp off In this state all keyboard operations are possible When the instrument is addressed to listen and a command is received the remote state will be entered and the REMOTE lamp will be turned on In this state the keyboard is locked out and remote commands only will be processe
98. although filtering can be selected and therefore become degraded above the frequencies indicated in the Specification all waveforms are however available up to the maximum frequency of the generator 4 1 2 Switching On The power switch is located at the bottom left of the front panel At power up the generator displays the installed software revision whilst loading its RAM with waveforms if an error is encountered the message SYSTEM RAM ERROR BATTERY FLAT will be displayed see the Warnings and Error Messages section Loading takes a few seconds after which the Main menu is displayed showing the generator parameters set to their default values with the MAIN OUT set off Refer to the System Menu section for how to change the power up settings to either those at power down or to any one of the stored settings GX1010 Il 9 10 Il Change the basic generator parameters as described in the Main Generator Operation section and switch the MAIN OUT on with the OUTPUT key the ON lamp will light to show that the output is on Note that AUX OUT CLOCK OUT etc are always running and are not switched by the OUTPUT key 4 1 3 Display Contrast All parameter settings are displayed on the 20 character x 4 row backlit liquid crystal display LCD The contrast may vary a little with changes of ambient temperature or viewing angle but can be optimised for a particular environment by using the front panel contrast control Insert a sma
99. angement de phase Ce d calage est d aux retards entre AUX OUT et MAIN OUT le compteur de salve et le circuit de contr le de phase Notez que ces effets arrivent m me quand la phase est 0 aux fr quences proches de 10mhz le d calage de phase peut tre 90 ou plus et la bande d incertitude s largit Du fait que ce effet est vu a phase 0 il est aussi vident quand AUX OUTPUT est en mode HIGH FREQ En fait le signal AUXOUT est d riv du signal sinus DDS filtr e dans ce mode et fait que le filtre ajoute des retards de phase cr ant des d calages de phase plus grands a une fr quence donn e qui apparaissent avec AUX OUTPUT en mode LOW FREQ En r sum les erreurs phase et l incertitude augmenteront mesure que la fr quence principale augmente au dessus de 30kHz m me avec un r glage phase 0 Cependant le contr le phase start stop peut tre utilis avec pr caution aux plus hautes fr quences en reculant la phase pour compenser les retards d s la technologie 4 4 4 Mode porte GATE Le mode Porte s active et se d sactive par pressions altern es de la touche GATE t moin la DEL sur le c t La s lection du signal source Porte GATE est faite partir du menu qui est choisi en appuyant sur EDIT puis PORTE GATE Quand GATE est choisi la DEL GX 1010 4 5 clignote pour montrer que le mode est dit sans regard et si l op ration GATE est activ e ou non SOURCE EXT TGEN 1 00ms 1 000kH
100. ans le menu principal 4 6 2 Source de d clenchement Avec le curseur dans la zone SOURCE du menu FSK les touches DIGIT ou la molette peuvent tre utilis es pour choisir EXT MAN REMOTE ou TGEN comme source de d clenchement qui contr le la d viation du signal Avec la source r gl e sur EXT la fr quence est commut e chaque front montant du signal appliqu l entr e EXT TRIG La largeur de l impulsion minimale qui peut tre utilis e avec l entr e EXT TRIG est 50ns et la vitesse de r p tition maximale est 1MHz Avec la source r gl e sur MAN REMOTE la fr quence est commut e a chaque pression de la touche MAN SYNC du panneau avant ou par la commande appropri e via RS232 ou GPIB Avec la source r gl e sur TGEN la fr quence est commut e chaque front montant du g n rateur d clenchement interne le g n rateur d clenchement produit un signal GX 1010 29 4 7 30 carr avec une p riode qui peut tre r gl e de 0 02ms 50kHz a 200s 005Hz Les entr es p riode qui ne peuvent tre r gl es exactement sont arrondies a la valeur sup rieure 0 109 ms est arrondie 0 12 ms La sortie g n rateur est disponible comme un signal niveau TTL la prise TRIG SWEEP OUT du panneau arri re R gler la fr quence du g n rateur d clenchement interne est compl tement d crit dans la section salve d clench e et porte Du fait que le g n rateur d clenchement interne peut tre
101. ant la touche bleue EDIT puis une touche MODE ou une touche num rique qui a une fonction secondaire en bleu Les touches FIELD d placent le curseur clignotant d une zone a une autre tous les chiffres d une valeur num rique sont trait s comme un seul caract re Quand les param tres d une fonction particuli re occupent plus d un cran les pages sont indiqu es par MORE gt gt gt et les touches FIELD permettent de naviguer d une page une autre Les attributs du curseur peuvent tre chang s voir section menu SYSt me Les touches DIGIT op rent dans plusieurs modes Quand un param tre num riques est choisi par les touches FIELD les touches DIGIT permettent de naviguer travers les chiffres du param tre Quand le curseur dition est positionn sur un nom de param tre ex FREQ presser la touche DIGIT Le param tre passe a travers chacune des formes alternatives dans lesquelles sa valeur peut tre entr e FREQ devient PER la valeur num rique et les unit s changent Notez que l ou il ny a pas de forme alternative pour certains param tres SYMMETRY le curseur ne passera pas dans le champs Quand le curseur est positionn dans un champ de s lection de param tres SOURCE dans le menu TRIG les touches DIGIT vont dans tous les choix possibles pour ce param tre SOURCE TGEN SOURCE EXT Enfin quand le curseur est dans les champs d unit d un param tre les touches DIGIT incr mentent ou d cr mente
102. ard Ces deux registres sont exploit s selon les imp ratifs d IEEE std 488 2 Tous les bits r gl s dans le Standard Event Status Register qui correspondent aux bits r gl s dans le Standard Event Status Enable Register entra nent le r glage du bit ESB dans le Status Byte Register Le Standard Event Status Register est lu et r initialis par la commande ESR Le Standard Event Status Enable Register est r gl par la commande ESE lt nrf gt et lu par la commande ESE Bit 7 Allumage R gl la premi re fois que l alimentation est appliqu e a l instrument Bit 6 Non utilis Bit 5 Command Error R gl lorsqu une erreur de type syntaxique est d tect e dans une commande du bus L analyseur syntaxique est r initialis et l analyse continue l octet suivant du flot d entr e Bit 4 Execution Error R gl lorsqu il se produit une erreur pendant une tentative d ex cution d une commande o la syntaxe est enti rement analys e Le num ro d erreur appropri est signal dans le Execution Error Register Bit 3 Non utilis Bit 2 Query Error R gl lorsqu une erreur d interrogation se produit Le num ro d erreur appropri est signal dans le Query Error Register comme indiqu ci dessous 1 erreur interrompue 2 erreur point mort 3 erreur non termin e Bit 1 Non utilis Bit O Operation Complete R gl en r ponse la commande OPC 5 1 5 2 Registre d tat par octet et registre d acti
103. as a TTL level 1 5V threshold In Triggered Burst mode the input is edge sensitive the rising edge of each external trigger initiates the specified burst In Gated mode the input is level sensitive the output of the main generator is on whilst the gate signal is high gt 1 5V The minimum pulse width that can be used with the EXT TRIG input is 50ns and the maximum repetition rate is 1MHz The maximum signal level that can be applied without damage is 10V 4 4 3 Triggered Burst Triggered Burst mode is turned on and off with alternate presses of the TRIG key the lamp beside the key lights when triggered mode is on The triggered mode parameters trigger source internal trigger generator burst count and start stop phase are all set from the trigger edit menu which is selected by pressing the blue EDIT key followed by the TRIG key When trigger edit is selected the lamp beside the TRIG key flashes to show edit mode regardless of whether triggered burst operation is currently selected to be on or off SOURCE EXT TGEN 1 00ms 1 000kHz BURST COUNT 0001 PHASE 000 000 4 4 3 1 Trigger Source With the edit cursor in the SOURCE field of the trigger edit menu the DIGIT keys or rotary control can be used to select EXTernal MAN REMOTE or internal Trigger GENerator as the trigger source With the source set to EXTernal the specified burst is triggered by the rising edge of a trigger signal applied to the EXT TRIG input see E
104. au Avant 4 1 6 1 SORTIE PRINCIPALE MAIN OUT C est la sortie 50Q du g n rateur principal Elle fournira jusqu 20V cr te cr te en f m qui produiront 10V cr te cr te dans une charge 50Q adapt e Elle peut accepter un court circuit pendant 60 secondes N appliquez pas de tension externe cette sortie 4 1 6 2 SORTIE AUXILIAIRE AUX OUT C est une sortie niveau TTL CMOS synchronis e avec MAIN OUT La sym trie est la m me que celle r gl e pour la sortie principale mais la relation phase entre MAIN OUT et AUX OUT est d termin e par le r glage PHASE sp cifi dans le menu d clenchement TRIG Les niveaux logiques AUX OUT sont OV et 5V partir de 50Q AUX OUT r sistera a un court circuit N appliquez pas de tension externe cette sortie 4 1 6 3 DECLENCHEMENT EXTERNE EXT TRIG C est l entr e externe d clenchement pour les modes Trigger Porte GATE Sweep FSK et HOP C est aussi l entr e utilis e pour synchroniser le g n rateur comme esclave un autre ma tre N appliquez pas de tension d passant 10 V 4 1 7 Connexions Panneau Arri re 4 1 7 1 ENTREE SORTIE CYCLE HORLOGE CLOCK IN OUT La fonction de la borne CLOCK IN OUT est r gl e a partir du menu SYSt me comme suit ENTREE La borne devient une entr e pour une horloge externe SORTIE C est le r glage par d faut Lhorloge interne est disponible sur la borne Quand deux ou plus de g n rateurs sont synchr
105. aux sont d riv s pr sentera lui m me un jitter 4 2 3 4 Arr t fr quence En mode FSTOP OFF il n y a pas de limites fr quence et la fr quence et le signal peuvent tre r gl es comme il est d crit dans la section g n rateur principal cependant la qualit du signal se d t riorera progressivement mesure que la fr quence augmente pour certaines formes de signal voir section principes DDS Avec FSTOP ON la fr quence maximale r glable pour triangle rampe escalier et arbitraire est limit e 100 kHz Des messages d erreur seront affich s si soit une tentative pour entrer une fr quence gt 100kHz pendant la s lection d un des signaux est faite ou une tentative de s lection de ces signaux alors que la fr quence est d j gt 100kHz Ce mode est utile pour assurer que les fr quences ne sont pas accidentellement r gl es trop haut pour des signaux dont la qualit sera d t rior e au del de 100kHz 4 2 3 5 Sortie D clenchement Balayage Trigger Sweep Output Avec la fonction SWEEP TGEN AUTO sur le panneau arri re la borne TRIG SWEEP OUT change automatiquement quand le mode de fonctionnement passe de SWEEP HOP ou un autre mode les deux fonctions de cette sortie sont d crits dans la section Connexions Quand SWEEP TGEN SWEEP est r gl la sortie TRIG SWEEP OUT est toujours en mode Sweep si le balayage fonctionne ou le mode HOP si HOP est activ quand SWEEP TGEN TRIG l
106. ce est r gl e dans les menus TRIG ou PORTE GATE Le front montant du g n rateur initialise le d clenchement la porte la salve etc En mode sweep la sortie est un signal 3 niveaux passant de haut 4V a bas OV en d but de balayage avec des impulsions d environ 1V aux marqueurs En mode HOP la sortie baisse en entrant a chaque chelon de forme du signal et monte apres que la nouvelle fr quence et la nouvelle forme du signal de cet chelon ont t r gl es Les niveaux de sortie sont OV et 4V partir de 1kQ TRIG SWEEP OUT supportera un court circuit A N appliquez pas de tension externe a cette sortie 4 1 7 5 RS 232 Connecteur D 9 broches compatible avec le syst me ARC Addressable RS232 Chain Les connexions broche sont montr es ci dessous Pin Nom Description 1 Pas de connexion interne 2 TXD donn e transmise de l instrument 3 RXD donn e re ue pour l instrument 4 Pas de connexion interne 5 GND Masse signal 6 Pas de connexion interne 7 RXD2 r ception donn e secondaire 8 TXD2 mission donn e secondaire 9 GND Masse signal Les broches 2 3 et 5 peuvent tre utilis es comme interface RS232 conventionnelle Synchro XON XOFF Les broches 7 8 et 9 sont utilis es en plus quand l instrument est connect l interface ARC Les masses signal sont connect es a la masse instrument L adresse ARC est r gl e du panneau avant en utilisant le menu I F 4 1 7 6 GPIB IEEE 488 L inter
107. chage change afin d amener l utilisateur ajuster le commutateur ou les touches FIELD DIGIT jusqu ce que la lecture de l instrument sp cifi atteigne la valeur donn e La touche FIELD donne un premier ajustement et le commutateur le pr cise Appuyer sur CONFIRM incr mente la proc dure vers le prochain chelon appuyer sur CE d cr mente vers l chelon pr c dent Appuyer sur ESCAPE permet de sortir vers le dernier l affichage CAL L utilisateur peut alors choisir soit de garder les nouvelles valeurs de calibration CONFIRM soit de revenir aux anciennes valeurs ESCAPE soit de recommencer la proc dure de calibrage CE Les deux premiers affichages CAL 00 et CAL 01 sp cifient les m thodes de connexions et d ajustement Les affichages r sultant CAL 02 a CAL 20 permettent tous les param tres ajustables d tre calibr s La proc dure compl te est la suivante CAL 02 D calage DC z ro Ajuster pour OV 5mV CAL 03 D calage DC gt 0 maximal Ajuster pour 10V 20mV CAL 04 D calage DC lt 0 maximal V rifier pour 10V 20mV CAL 05 Multiplicateur d calage au 0 Ajuster pour minimum CAL 06 D calage signaux Noter la valeur lue VDC CAL 07 D calage signaux Ajuster pour la m me valeur CAL 06 10mV CAL 08 D calage signaux DC Ajuster pour OV 5mV CAL 09 Signaux maximaux Ajuster pour 10V 10mV CAL 10 Signaux carr s maximaux Ajuster pour 10V 10mV CAL 11 att nuateur 20dB Ajuster pour 1V 1mV CAL 12 att nuateur 40dB Aju
108. cient to know that at low frequencies the addresses are output sequentially but at higher frequencies the addresses are sampled The major advantages of DDS over conventional analogue generation are e Frequency accuracy and stability is that of the crystal oscillator e Frequencies can be set with high resolution from mHz to MHz e Low phase noise and distortion e Very wide frequency sweeps are possible e Fast phase continuous frequency switching e Non standard waveforms such as multi level squarewaves are easily generated e Basic arbitrary waveform capability in the same instrument In addition being a digital technique it is easier to make every parameter programmable from the keyboard or remotely via RS 232 or GPIB interfaces The fundamental limitation of the DDS technique is that as the generator frequency is increased each waveform cycle is constituted from fewer samples This is not a problem with sinewaves which because they are filtered can be produced with low distortion up to the frequency limit of the generator With DDS squarewaves and pulse waveforms the 1 clock edge uncertainty sets a practical limit to the upper frequency However on this instrument the generation technique changes at 30kHz but is overridable by the user to use a comparator driven by the DDS sinewave this ensures jitter free squarewaves and pulses up to the frequency limit of the generator Ramp and staircase waveforms are by default unfiltered
109. clench e Le mode Salve d clench e s active et s teint par pressions altern es de la touche TRIG la DEL situ e c t de la touche est allum e lorque la fonction est active Les param tres du mode d clench source de d clenchement g n rateur d clenchement interne compteur de salve et start stop de phase sont tous r gl s du menu d clenchement qui est s lectionn en pressant EDIT puis TRIG Quand l dition d clenchement est choisie la DEL pr s de TRIG clignote pour montrer que la fonction est dit e sans regard si le mode Salve BURST est activ ou desactiv SOURCE EXT TGEN 1 00ms 1 000kHz SALVES BURST COUNT 0001 PHASE 000 000 4 4 3 1 Source de d clenchement Avec le curseur dans la zone source du menu les touches DIGIT ou la molette peuvent tre utilis es pour choisir EXTerne MAN REMOTE ou GEN rateur d clenchement interne comme source de d clenchement Avec la source r gl e EXTerne la salve sp cifi e est d clench e par le front montant d un signal d clencheur appliqu l entr e EXT TRIG voir section entr e de d clenchement externe Avec la source r gl e sur MAN REMOTE une salve peut tre initi e en pressant MAN SYNC ou par la commande appropri e via RS232 ou GPIB Avec la source r gl e sur TGEN la salve est d clench e en interne section G n rateur d clenchement interne La p riode du g n rateur interne est r gl e dans la zone TG
110. commands The addressed instrument will provide this ACK The controller should time out and try again if no ACK is received within 5 seconds Listen mode will be cancelled by any of the following interface control codes being received 12H LAD Listen Address followed by an address not belonging to this instrument 14H TAD Talk Address for any instrument 03H UNA Universal Unaddress control code 04H LNA Lock Non Addressable mode control code 18H UDC Universal Device Clear Before a response can be read from an instrument it must be addressed to talk by sending the Talk Address control code 14H TAD followed by a single character which has the lower 5 bits corresponding to the unique address of the required instrument as for the listen address control code above Once addressed to talk the instrument will send the response message it has available if any and then exit the talk addressed state Only one response message will be sent each time the instrument is addressed to talk Talk mode will be cancelled by any of the following interface control codes being received 12H LAD Listen Address for any instrument 14H TAD Talk Address followed by an address not belonging to this instrument 03H UNA Universal Unaddress control code 04H LNA Lock Non Addressable mode control code 18H UDC Universal Device Clear GX1010 Il 39 40 Il Talk mode will also be cancelled when the instrument has completed sending a response message or
111. comparator is now being driven by an LF mode waveform instead of the filtered sinewave 6 5 2 3 Frequency Modes for Sweep and FSK For Sweep and FSK operation the MAIN and AUX waveform modes are fixed HF or LF even if the setting on the Option menu is AUTO The setting under these circumstances is that of the main generator before Sweep or FSK were turned on For example if the two FSK frequencies are 25kHz and 50kHz and 25kHz was the main generator frequency before FSK was turned on FSK waveforms will be LF mode In both cases however the automatic choice can be overridden by selecting HF or LF instead of AUTO in the SQWAVE GEN and AUX fields of the Options menu 6 5 2 4 Phase shifted Asymmetric Waveforms The interaction of symmetry adjustment and start stop phase of triggered bursts gives waveforms which are difficult to anticipate In principle adjusting the symmetry moves the 180 phase point from the 50 50 position of 50 symmetry to for example the 40 60 point of 40 symmetry The 0 180 points are now mathematically scaled to fit into 40 of the cycle and 180 360 points are interpolated to fit into 60 of the cycle Start stop phase still works with the true phase settings but they are not necessarily at the expected point on the waveform particularly for more complex waveshapes GX1010 Il 59 7 2 60 Il SPECIFICATIONS General Only the values assigned tolerances or limits are guaranteed values Values wit
112. d un composant n utilisez que des composants d un type identique Stockage Afin de garantir la pr cision apr s une dur e de stockage dans des conditions d environnement extr mes il est conseill d attendre le temps n cessaire l appareil pour revenir dans les conditions normales d utilisation voir sp cifications d environnement Accessoires et options 7 5 1 Accessoires 7 5 1 1 Livr s avec l appareil 1 cordon secteur 1 notice de fonctionnement GX 1010 ANNEXE 1 Messages d erreur et d alerte Les messages d erreur sont donn s quand un r glage ne rend pas le r sultat attendu par exemple lorsque le d calage DC est diminu par l att nuateur de sortie alors que l amplitude fix e est faible les r glages sont quand m me impl ment s Les messages d erreur apparaissent dans le cas d un r glage irr alisable les r glages pr c dents sont alors gard s Il est possible de consulter les deux derniers messages d alerte ou d erreur Ceci peut tre fait en appuyant sur EDIT suivi par MSG MAJ 0 Le dernier message est visionn le premier Les messages d alerte et d erreur sont rapport s accompagn d un num ro seul ce num ro est rapport via les interfaces distance La liste suivante regroupe tous les messages tels qu ils apparaissent cran Dans la plupart des cas ils parlent d eux m mes mais dans les cas ambigus une explication plus compl te est donn e e Message
113. d The instrument may be returned to the local state by pressing EDIT which doubles as the LOCAL key however the effect of this action will remain only until the instrument is addressed again or receives another character from the interface when the remote state will once again be entered 5 1 1 Address and Baud Rate Selection For successful operation each instrument connected to the ARC or GPIB must be assigned a unique address and in the case of ARC all must be set to the same baud rate The instruments remote address for operation on both the ARC and GPIB interfaces is set via the InterFace menu accessed by pressing the I F button REMOTE RS232 ARC ADDRESS 05 BAUD RATE 9600 With the edit cursor in the REMOTE field the selected interface can be toggled between RS232 and GPIB with alternate presses of the DIGIT keys or by using the rotary control If no GPIB interface is fitted an error message will show if GPIB selection is attempted and the setting will be left at RS232 The address is selected with the edit cursor in the ADDRESS field using the DIGIT keys or rotary control Lastly the baud rate is selected with the edit cursor in the BAUD RATE field again using the DIGIT keys or rotary control When operating on the GPIB all device operations are performed through a single primary address no secondary addressing is used NOTE GPIB address 31 is not allowed by the IEEE 488 standards and it is not possible to select
114. d TGEN PERIOD gt lt TGEN PERIOD gt Set the main generator to 10kHz 10Vpp by pressing FREQ 1 0 kHz and EMF 1 0 V change the symmetry to 60 40 by pressing SYM 6 0 DC OFFSET 0 V select TRIANGLE Select the Trigger menu by pressing EDIT TRIG and set SOURCE TGEN i e internal trigger generator Set the TGEN period to 1ms 1 000kHz the BURST COUNT to 000 5 and the PHASE to 90 If it is off set Trigger mode on by pressing TRIG again The waveform should be that shown in the diagram The rise and fall times can be reduced by increasing the main generator frequency and the relationship between rise and fall time can be altered by changing the symmetry 6 4 2 Band limited Pulses The edges of band limited pulses are sinewave segments starting from 90 Normally the rise and fall times will be equal so the main generator symmetry is set to 50 Following on from the example above Set SYM 5 0 GX1010 Il 55 6 5 56 Il Select SINE If the trigger parameters have been changed from the above example re enter them lee MAIN PER PER x x EM gt 1 SYM gt a TGEN PERIOD lt TGEN PERIOD gt 6 4 3 Pulses with Overshoot The edges and overshoot peaks are sinewaves The amount of overshoot depends on the starting phase angle which will be from 89 to about 30 The Main generator amplitude determines the amplitude of
115. d alerte et d erreur 4 2 1 5 Sortie DC DC output Le contr le de l offset DC peut tre utilis pour fournir un niveau de sortie courant continu ajustable si la forme du signal est off le reglage recommand est le suivant S lectionnez le mode PORTE GATE et r glez SOURCE sur MAN REMOTE Sortez du mode et activez le mode PORTE GATE avec la touche PORTE GATE Etant donn que le mode PORTE GATE n est pas d clench Main OUT sera maintenant au niveau r gl par le contr le d offset DC Sur le menu principal r glez le niveau de sortie 1Vpp ceci assure que le logiciel n aura pas de rupture niveau de sortie trop haut et que l att nuateur de sortie n est pas activ ce qui att nuerait l offset DC Avec le curseur dans la zone offset DC MAIN OUT peut maintenant tre ajust au dessus de la gamme 10V EMF 4 2 1 6 Sym trie Presser la touche SYMMETRY envoie le curseur directement dans la zone de sym trie num rique ligne du bas C est la seule zone ditable La zone entre parenth ses montre la sym trie r elle qui peut diff rer de celle r gl e si la valeur r gl e est au del du domaine permis par la combinaison signal fr quence choisie voir la section sp cifications techniques Par exemple l affichage ci dessous nous donne une fr quence de 100 kHz et un signal carr est choisi FREQ 100 0000kHz EMF 20 0 Vpp 500 DC 0 00mV 0 00mV SYM 90 0 80 0 La sym trie est
116. de mise sous tension est en bas gauche du panneau avant A l allumage le g n rateur affiche la r vision logicielle pendant le chargement en RAM des signaux si une erreur survient le message SYSTEM RAM ERROR BATTERY FLAT appara tra voir section messages d erreur et d alerte Le changement prend quelques secondes apr s lesquelles le menu est affich montrant les param tres g n rateur r gl s a ses valeurs par d faut avec MAIN OUT sur off R f rez vous a la section mode d op ration pour changer les r glages de d part GX 1010 EE I 10 Changez les param tres de base comme dans la section fonctions de base et branchez MAIN OUT avec la touche OUTPUT la DEL ON s allumera pour montrer que la sortie est active Notez que AUX OUT CLOCK OUT etc fonctionnent toujours et ne sont pas connect s par la touche OUTPUT 4 1 3 Contraste de l affichage Tous les r glages des param tres sont affich s sur l cran LCD de 20 Car x 4 lignes Le contraste peut varier un peu avec les changements de temp rature ambiante ou d angle de vue mais peut tre optimis pour un milieu particulier en utilisant le contr le contraste du panneau avant Ins rez un petit tournevis dans l orifice de r glage marqu LCD et tournez le contr le pour un contraste optimal 4 1 4 Clavier Les touches peuvent tre divis es en 7 groupes e Les touches FUNCTION permettent une s lection directe de la forme de signa
117. de visualiser les caract res disponibles les touches DIGIT sont utilis es pour d placer le curseur de num ro en num ro SAVE ARB TO STORE 01 NOM USE DIGIT DIAL WAVE _ CONFIRM TO EXECUTE L affichage ci dessus montre le nom WAVE entr Quand le nom est complet appuyez sur CONFIRM pour sauvegarder le signal et son nom dans la m moire demand e Un bip de confirmation est donn et l affichage renvoie le menu a RECALL ARB No nn nn tant le num ro de stockage venant juste d tre sauvegard 4 7 3 Bruit de fond Noise Le g n rateur peut tre r gl de fa on sortir un bruit pseudo al atoire dans la largeur de bande 0 03Hz 700kHz Afin de faire fonctionner cette largeur de bande un simple filtre RC est toujours connect au lieu du filtre standard 7 tages quel que soit le r glage FILTRE du menu Options se reporter la section Options sur la G n ration de signaux L amplitude et le d calage sont ajustables et le bruit peut tre utilis dans les modes GATE et AM Noise est s lectionn partir du menu Noise Pour y acc der appuyer sur la touche bleue EDIT suivie de NOISE touche 4 Noise peut tre activ ou desactiv en appuyant alternativement sur les touches DIGIT ou en tournant la molette Quand Noise est allum la DEL cot de la FUNCTION utilis e en dernier clignotera et aucune autre fonction ne peut tre s lectionn e m me STAIR et ARB Une fois Noise activ appuyer
118. ders is prohibited This instrument uses a Lithium button cell for non volatile memory battery back up typical life is 5 years In the event of replacement becoming necessary replace only with a cell of the correct type i e 3V Li Mn02 20mm button cell type 2032 Exhausted cells must be disposed of carefully in accordance with local regulations do not cut open incinerate expose to temperatures above 60 C or attempt to recharge GX1010 Il 1 1 2 1 3 2 Il Do not wet the instrument when cleaning it and in particular use only a soft dry cloth to clean the LCD window The following symbols are used on the instrument and in this manual 1 1 3 Symbols AN See user s manual Incorrect operation may damage the instrument Earth terminal 1 1 4 Safety instructions e Never open the instrument without first disconnecting from the mains power supply and any measuring circuits Caution The generator contains capacitors which may retain hazardous charges even after being isolated from the supply voltage e Any adjustment maintenance or repair work carried out on the regerator while it is live should be carried out only by appropriately qualified personnel Warranty METRIX equipment is warranted against any defects of manufacture or materials for a period of two years from the date of delivery During this period defective parts will be replaced the manufacturer reserving the right to repair or replace the product In t
119. ds EMFPP lt nrf gt Set output level to lt nrf gt emf Vpp EMFRMS lt nrf gt Set output level to lt nrf gt emf Vrms PDPP lt nrf gt Set output level to lt nrf gt pd Vpp PDRMS lt nrf gt Set output level to lt nrf gt pd Vrms DBM nrf gt Set output level to lt nrf gt pd dBm ZOUT lt nrf gt Set output impedance to lt nrf gt only 50 or 600 are legal DCOFFS lt nrf gt Set dc offset to lt nrf gt Volts SYMM lt nrf gt Set symmetry to lt nrf gt PHASE lt nrf gt Set phase to lt nrf gt degrees 5 2 3 Sweep Parameters SWEEP lt cpd gt Set sweep mode to lt ON gt or lt OFF gt SWPBEGFRQ lt nrf gt Set sweep begin frequency to lt nrf gt Hz 46 Il GX1010 5 2 4 Trigger and Gate 5 2 5 AM Parameters 5 2 6 FSK Parameters GX1010 SWPBEGPER lt nrf gt SWPENDFRQ lt nrf gt SWPENDPER lt nrf gt SWPMKRFRQ lt nrf gt SWPMKRPER lt nrf gt SWPMODE lt cpd gt SWPLAW lt cpd gt SWPTIME lt nrf gt SWPSRC lt cpd gt TRG TRIG lt cpd gt GATE lt cpd gt TRIGSRC lt cpd gt GATESRC lt cpd gt TGEN lt nrf gt BCNT lt nrf gt PHASE lt nrf gt TRG AM lt cpd gt AMSRC lt cpd gt TGEN lt nrf gt AMDEPTH lt nrf gt AMWAVE lt cpd gt FSK lt cpd gt FSKFRQA lt nrf gt FSKPERA lt nrf gt FSKFRQB lt nrf gt FSKPERB lt nrf gt FSKSRC lt cpd gt TGEN lt nrf gt TRG Set sweep begin period to lt nrf gt seconds Set sweep end frequency to lt nrf gt Hz Set swee
120. e The approximate timings for each change from the trigger edge are as follows e Frequency only 0 5ms Frequency changes are phase continuous e Frequency and waveshape 3ms but longer if the filter is switched as well e Amplitude and Offset Up to 40ms If the new amplitude setting involves an attenuator change the output is switched off for 45ms whilst the change is made to prevent any transients appearing at the output The synchronising signal at the rear panel TRIG SWEEP OUT socket is a low going pulse whose falling edge occurs at the start of each step this is about 1ms after an external trigger The rising edge occurs just after the completion of a frequency or waveshape change i e 0 5ms or 3ms later respectively For an amplitude and or offset change the rising edge occurs slightly later but well before the 40ms delay needed to guarantee the change has been completed however if the amplitude change causes the attenuator to be switched the rising edge will occur after the attenuator has changed and the output has been switched back on GX1010 Il 33 4 9 34 Il The set duration of the step is timed from the rising edge of the synchronising signal at the TRIG SWEEP OUT socket The minimum step duration of 2ms can be used for frequency only changes but the time needed to implement waveshape amplitude offset changes determines a practical minimum which is greater than this Recommended times are gt 10ms for frequency
121. e Trigger signal will produce one burst of the carrier starting and stopping at the phase angle specified by the start stop phase setting The number of cycles in the burst can be set between 0 5 and 1023 The Gated mode turns the output signal On when the gating signal is high and Off when it is low Both Triggered and Gated modes can be operated from the internal Trigger Generator 0 005Hz to 50kHz or from an external source dc to 1MHz Waveform Hop amp Noise The generator can be set up to hop between a number of different waveform set ups either at a pre determined rate or in response to a manual trigger Up to 16 different hop waveforms can be defined in terms of frequency amplitude function offset and duration which is variable in 1ms steps up to 60s The generator can also be set to simulate random noise within the bandwidth 03Hz to 700kHz with adjustable amplitude and offset Multiple phase locked generators The signals from the Clock In Out socket and the Sync Out socket can be used to phase lock two or more generators This can be used to generate multi phase waveforms or locked waveforms of different frequencies Easy and convenient to use All of the main generator parameters are clearly displayed together on a backlit LCD with 4 rows of 20 characters Sub menus are used for the modulation modes and other complex functions All parameters can be entered directly from the numeric keypad Alternatively most pa
122. e annul en choisissant le mode fr quence haute ou basse dans le mode options comme d crit ci dessus 4 2 3 2 Filtre Le g n rateur poss de un filtre elliptique 7 tapes qui a la particularit de se d sactiver au del de la fr quence maximale du g n rateur r duisant l intermodulation et les harmoniques de cycle un tr s bas niveau Avec la condition par d faut FILTER AUTO r gl e dans le menu options le filtre est commut automatiquement pour les signaux sinus triangle carr s haute fr quence impulsion haute fr quence bien que les signaux carr s et impulsion ne passent pas travers le filtre le filtre est automatiquement d sactiv pour les signaux carr s impulsion rampe escalier et arbitraires basse fr quence cause de l effet d gradant qu il a sur les transitions rapides dans la forme de signal Cependant pour tous ces signaux le filtre peut tre r gl toujours sur on FILTER ON ou toujours sur off FILTER OFF Ceci pr sente l avantage de pouvoir sortir par exemple un signal arbitraire avec un contenu essentiellement sinuso dal en ayant le filtre activ GX 1010 Quand le bruit est activ voir section Signaux sp ciaux ce filtre est toujours d sactiv quel que soit le r glage et un simple filtre RC passe bas a 700 kHz est commut a la place 4 2 3 3 Sortie auxiliaire Quand les signaux sinusoidaux triangulaires carr s ou impulsionnels sont choisis avec AUX
123. e en forme des commandes aucun instrument n en tiendra compte La plupart des instruments termineront les r ponses par CR suivi de LF L appareil de r ception instrument ou contr leur peut transmettre tout moment le code d interface 13H XOFF pour arr ter la sortie d un appareil metteur L appareil de r ception doit transmettre le code 11H XON avant que l appareil metteur recommence la transmission C est la seule forme de contr le d tablissement de liaison g r e par ARC 5 1 2 4 Liste des codes de contr le de l interface ARC 02H SAM Set Addressable mode 03H UNA Code de contr le Universal Unaddress 04H LNA Code de contr le Lock Non Addressable mode 06H ACK ACknowledge adresse d coute re ue OAH UCT Universal Command and response Terminator ODH CR Code de mise en forme sinon ignor 11H XON Recommencement de la transmission 12H LAD Listen Address doit tre suivi d une adresse utilis e par l instrument requis 13H XOFF Arr t de transmission 14H TAD Talk Address doit tre suivi d une adresse utilis e par l instrument requis 18H UDC Universal Device Clear GX 1010 41 42 5 1 3 Interface GPIB Lorsque l interface GPIB est fix e le connecteur 24 voies GPIB est situ sur le panneau arri re de l instrument Les connexions des broches correspondent celles qui sont sp cifi es dans la norme IEEE Std 488 1 1987 et l instrument satisfait aux normes IEEE Std 488 1 1987 et IEE
124. e illegal when synchronous slave 24 Burst time exceeds TGEN period 25 DC Offset level may cause clipping e Error Messages 101 Frequency Period Val out of range 102 Max Output level exceeded 103 Min Output level exceeded 104 Requested units are illegal here 105 Min DC Offset exceeded 106 Max DC Offset exceeded 108 Symmetry value is illegal 112 Trigger generator period too big 113 Trigger generator period too small 115 Burst count value out of range 116 Phase angle value out of range 118 Trigger generator fixed by am sine 119 Mod depth value out of range GX1010 The following messages are only relevant to remote control operation GX1010 121 126 127 128 134 135 136 System ram error battery flat Sweep time is too long Sweep time is too short No GPIB interface is available Illegal HOP step number requested HOP time value out of range Unable to phase lock to master e Error Messages Remote Control Only 129 130 131 132 133 Illegal store number requested Byte value outside the range 0 to 255 Illegal value in staircase data Illegal ARB store Illegal value in arbitrary data Il 67 ANNEXE 2 Factory System Defaults The factory system defaults are listed in full below They can be recalled by pressing Recall 0 Confirm or by the remote command RST Main Menu Parameters Trigger Parameters Gate Parameters FSK Parameters AM Parameters STAIR Parameters ARB Para
125. e n est utilis e L adresse GPIB 31 n est pas accept e par les IEEE 488 standards et il est impossible de la s lectionner m me comme une adresse ARC GX 1010 5 1 2 Interface ARC 5 1 2 1 Connexions d Interface ARC Le connecteur d interface s rie a 9 voies type D se trouve sur le panneau arri re de l instrument Les connexions des broches sont indiqu es ci dessous Broches Nom Description 1 Pas de connexion interne 2 TXD Donn es transmises de l instrument 3 RXD Donn es re ues l instrument 4 Pas de connexion interne 5 GND Signal terre 6 Pas de connexion interne 7 RXD2 Donn es secondaires re ues voir le sch ma 8 TXD2 Donn es secondaires transmises voir le sch ma 9 GND Signal terre Les broches 2 3 et 5 peuvent tre utilis es en tant qu interface classique RS232 avec tablissement de liaison XON XOFF Les broches 7 8 et 9 sont en outre utilis es lorsque l instrument est reli l interface ARC On peut effectuer un syst me de connexion en cha ne en guirlande entre diff rents instruments maximum 32 au moyen d un seul c ble de la mani re indiqu e ci dessous CONTROLEUR INSTRUMENT INSTRUMENT INSTRUMENT 1 2 3 A L INSTRUMENT SUIVANT La cha ne en guirlande est constitu e des lignes de donn es de transmission TXD de r ception RXD et des lignes de terre de signaux uniquement ll n y a pas de lignes de commande tablissement de liaison Ceci
126. e nouvelle ligne avec le message END AENDMessage END avec le dernier caract re du message Un lt PROGRAM MESSAGE UNIT SEPARATOR est le point virgule 3BH GX 1010 5 2 Un lt PROGRAM MESSAGE UNIT gt est l une des commandes de la section COMMANDES A DISTANCE Les r ponses de l instrument au contr leur sont transmises en tant que lt RESPONSE MESSAGES gt Un lt RESPONSE MESSAGE gt est compos d un lt RESPONSE MESSAGE UNIT gt suivi d un lt RESPONSE MESSAGE TERMINATOR gt Un lt RESPONSE MESSAGE TERMINATOR gt est le caract re de nouvelle ligne avec le message END NL END Chaque interrogation produit un lt RESPONSE MESSAGE gt sp cifique list avec la commande dans la section COMMANDES A DISTANCE Il n est pas tenu compte de lt WHITE SPACE gt sauf dans les identificateurs de commande par exemple C LS n est pas quivalent CLS lt WHITE SPACE gt est d fini comme le code de caract res 00H 20H inclus l exception du caract re NL OAH Il n est pas tenu compte du bit niveau haut des diff rents caract res Les commandes acceptent des minuscules et majuscules Commandes distance Les sections suivantes indiquent toutes les commandes et interrogations ex cut es dans cet appareil de mesure Afin de rendre leur utilisation plus facile les commandes sont group es de fa on correspondre aux menus d roulants Le RESUME DES COMMANDES A DISTANCE liste toutes les commandes en ordre alphab ti
127. e num ro 0 renferme des d fauts usine qui peuvent tre eux aussi recharg s de la m me fa on Notez que le fait de charger les d fauts n affectera ni le r glage HOP ni aucun des autres r glages stock s dans les m moires 1 9 4 9 2 Mode de R glages Cette section traite de certains r glages du syst me pouvant tre chang s selon les voeux de l utilisateur C est dire le curseur les r glages concernant le d marrage et l tat du commutateur rotatif De plus le r le de la borne CLOCK IN OUT du panneau arri re est r gl e partir de ce menu CURSOR CHAR 0 DIAL UNLOCKED POWER UP DEFAULTS CLOCK BNC OUTPUT 4 9 2 1 Style de Curseur Le style du curseur peut tre s lectionn dans le champ CURSOR CHAR Le style par d faut est d alterner entre le caract re d cran clignotant et le soulignement les autres possibilit s sont un rectangle entier un rectangle ouvert et un blanc Servez vous du commutateur pour s lectionner le style d sir GX 1010 35 4 10 36 4 9 2 2 Contr le rotatif La condition par d faut pour le commutateur est UNLOCKED d verrouill donc actif R glez le champ DIAL sur LOCKED avec les touches DIGIT afin de rendre le commutateur inactif 4 9 2 3 R glages de d marrage Quand le curseur est dans le champ POWER UP le r glage peut tre chang de POWER UP DEFAULTS r glages par d faut POWER UP POWER DOWN les r glages sous power down sont
128. e sur lt ON gt or lt OFF gt R gle la source de d clenchement sur lt EXT gt lt MAN gt ou lt TGEN gt R gle la source de la porte sur lt EXT gt lt MAN gt ou lt TGEN gt GX 1010 TGEN lt nrf gt BCNT lt nrf gt PHASE lt nrf gt TRG Fixe la p riode du g n rateur de d clenchement lt nrf gt secondes Fixe le d compte de la salve BURST a lt nrf gt cycles Fixe la phase a lt nrf gt degr s Provoque un d clenchement qui aura le m me effet que d appuyer sur la touche MAN SYNC La source de d clenchement MAN REMOTE doit tre s lectionn e en premier La commande Group Execute Trigger GET remplira la m me fonction que TRG 5 2 5 Param tres AM Modulation d amplitude AM lt cpd gt AMSRC lt cpd gt TGEN lt nrf gt AMDEPTH lt nrf gt AMWAVE lt cpd gt 5 2 6 Param tres FSK FSK lt cpd gt FSKFRQA lt nrf gt FSKPERA lt nrf gt FSKFRQB lt nrf gt FSKPERB lt nrf gt FSKSRC lt cpd gt TGEN lt nrf gt TRG Fixe le mode AM sur lt ON gt ou lt OFF gt R gle la source AM a sur lt EXT gt ou lt TGEN gt Fixe la p riode de g n rateur de d clenchement lt nrf gt secondes Fixe la profondeur de modulation interne AM a lt nrf gt Fixe le signal interne AM sur lt SINE gt ou lt SQUARE gt Fixe le mode FSK sur lt ON gt ou lt OFF gt Fixe la fr quence du g n rateur principal a lt nrf gt Hz Fixe la p riode du g n rateur principal lt nrf gt F
129. eant le curseur avec les touches FIELD et en utilisant les touches DIGIT ou la molette pour changer le r glage 4 2 3 1 G n ration de signaux carr s En mode LOW FREQ les signaux carr s et impulsion sont g n r s num riquement de cette mani re des signaux carr s pr cis peuvent tre g n r s jusqu de tr s basses fr quences sans rebond qui pourraient tre caus s par des techniques de rampe et comparateur conventionnelles Au dessus d environ 27kHz Fr quence 27 487MHz 1024 les signaux sont chantillonn s et l incertitude d un cycle 36ns provoque un jitter qui devient plus significatif haute fr quence En mode HIGH FREQ les signaux carr s et impulsion sont d riv s de la sortie d un comparateur pilot par un signal sinus g n r par DDS Le signal sinus est par d faut filtr et sans jitter les signaux carr s et impulsionnels haute fr quence sont aussi sans jitter En mode AUTO d faut la g n ration de signaux carr s et d impulsion est automatiquement commut e du mode basse haute fr quence quand la fr quence d passe 30kHz Cependant quand ces signaux sont utilis s en mode SWEEP ou FSK au del d une gamme de fr quence qui inclut le point de changement 30kHz le mode g n ration ne changera pas m me si AUTO est choisi A la place le mode utilis avant que SWEEP ou FSK soient activ s est maintenu travers la gamme de fr quences ceci peut bien s r tr
130. ectly from the keyboard using the key to change the sign if necessary or by rotary control Above 30kHz the AUX OUT accompanying sine triangle square and pulse waveforms is automatically switched such that it is derived from the comparator driven by the DDS sinewave used to generate higher frequency MAIN OUT squarewaves and pulses see the DDS Principles section for further information This ensures a jitter free AUX OUT signal up to the maximum frequency of the generator but means that phase shifting between MAIN OUT and AUX OUT is not then possible However this constraint can be removed by changing the setting on the OPTions menu from AUX OUTPUT AUTO to AUX OUTPUT LOW FREQ the AUX OUT signal then continues to be generated independently with phase adjustable with respect to the MAIN output although the 1 clock 36ns jitter will become increasingly significant at higher frequencies Changing AUTO settings is described more fully in the next section Waveform Generator Options The AUX OUT signal accompanying ramp staircase and arbitrary waveforms is by default always generated independently phase shift is adjustable across the frequency range but again clock jitter becomes increasingly significant at higher frequencies GX1010 Il 19 20 Il 4 2 3 Waveform Generation Options A number of parameters are by default switched automatically either when the frequency is set above 30kHz or when the operating
131. ed out for low frequency squarewave and pulses ramp staircase and arbitrary waveforms because of the degrading effect it has on fast transitions in the waveform However for all these waveforms the filter can be set to be always on FILTER ON or always off FILTER OFF this has the advantage that for example an arbitrary waveform with an essentially sinusoidal content can be output with the filter on GX1010 4 3 When Noise is selected see Special Waveforms section this 7 stage filter is always off whatever the FILTER setting and a simple 700kHz low pass RC filter is switched in instead 4 2 3 3 Auxiliary Output When sine triangle squarewave or pulse waveforms are selected and with AUX OUTPUT AUTO the auxiliary output squarewave generation switches automatically at 30kHz from DDS generation to a signal derived from a comparator driven by the DDS sinewave the advantages of this approach are the same as those detailed previously in the Squarewave Generation section However as detailed in the Auxiliary Output Phase section the high frequency generation mode has the disadvantage that a phase difference can no longer be set between AUX OUT and MAIN OUT The automatic switchover at 30kHz can therefore be overridden by setting AUX OUTPUT LOW FREQuency to maintain it in true DDS mode or AUX OUTPUT HIGH FREQuency to lock it in high frequency mode With AUX OUTPUT AUTO there is no automatic mode changeover if ramp staircase or arbi
132. edit cursor is positioned in a parameter selection field e g SOURCE on the TRIG menu the DIGIT keys step through all possible choices for that parameter e g SOURCE TGEN SOURCE EXT etc Lastly when the edit cursor is positioned in the units field of a parameter value the DIGIT keys increment or decrement the numeric value of the parameter by a factor of 10 each press the units change each time the display autoranges The ROTARY CONTROL works as follows With the cursor in any field other than a numeric value field turning the control acts in exactly the same way as pressing the DIGIT keys With the edit cursor positioned anywhere in a parameter numeric field turning the control will increment or decrement the value the step size is determined by the position of the edit cursor within the numeric field Thus for FREQ 1 00000 MHz rotating the control will change the frequency in 1kHz steps The display will auto range up or down as the frequency is changed provided that autoranging permits the increment size to be maintained this will in turn determine the lowest or highest setting that can be achieved by turning the control In the example above the lowest frequency that can be set by rotating the control is 1 kHz shown on the display as FREQ 1 000000 kHz This is the limit because to show a lower frequency the display would need to autorange below 1kHz to FREQ xxx xxx Hz in which the most significant digit represents
133. elds in turn using the FIELD keys The field can then be toggled between ON and OFF using the DIGIT keys or rotary control to create the desired setting If the new setting is required for future use it should be saved by changing the POWER UP setting on the SYStem menu to POWER UP POWER DOWN see System Menu section GX1010 4 2 2 Auxiliary Output AUX OUT is a TTL CMOS level output synchronous with MAIN OUT and with the same symmetry However the phase of the AUX OUT can be varied with respect to the MAIN OUT by changing the PHASE setting on the TRIGger edit menu 4 2 2 1 Auxiliary Output Phase Triangle AUX 0 AUX 90 AUX 180 0 180 360 The convention adopted for phase in this instrument is illustrated in the diagram 0 is always the first data point in waveform memory On symmetrical waveforms 0 is the rising edge zero crossing point for sine square triangle and pulse waveforms 0 is the start point of ramps staircase and arbitrary waves When the phase is set to 0 the rising edge of the AUX OUT squarewave is at 0 too When the phase is set to a positive value e g 90 the AUX OUT squarewave follows MAIN OUT by 90 when the phase is set to a negative value AUX OUT leads MAIN OUT The phase is set by pressing the blue EDIT key followed by TRIG to select the trigger edit menu the edit cursor is then moved to the PHASE field using the FIELD keys PHASE can be entered dir
134. endra dans le champ LENGTH et le champ STEP sera incr ment de 1 pr t pour la nouvelle entr e Si AUTO a t r gl sur NO le d placement entre LENGTH et LEVEL et l incr mentation de STEP doit tre faite manuellement Le signal escalier est fait partir des chelons 00 01 02 etc dans l ordre num rique jusqu l chelon qui am ne la longueur soit au total de 1024 tous les chelons ayant une GX 1010 longueur nulle seront indiqu s ACTIVE cot de leur num ro d chelon dans l affichage car le changement de LENGTH ou LEVEL de l un d eux affecterait le signal Ces chelons situ s apr s le dernier chelon actif seront indiqu s INACTIVE m me s ils ont une longueur non nulle car leur changement n affectera pas le signal Si la longueur du dernier chelon actif passe au dessus de 1024 alors les chantillons en plus seront ignor s mais toute la longueur est affich e si le dernier chantillon actif n a pas les chantillons suffisants pour amener le total 1024 alors la fin du signal est remplie avec un nombre n cessaire d chantillons avec LEVEL 000 L dition de signaux force la sym trie 50 pour simplifier les entr es quand le mode edit est termin la sym trie du signal se retrouvera ce qui t sp cifi dans le menu principal 4 7 2 Arbitraire Jusqu 5 signaux arbitraires d finis par l utilisateur peuvent tre install s via les interfaces RS232 ou GPIB et sauvegard
135. ension Les signaux sinuso daux et triangulaires sont filtr es afin de lisser les diff rents niveaux dans la sortie DAC La fr quence de la forme des signaux de sortie est d termin e par la vitesse laquelle les adresses RAM sont chang es dans un syst me DDS les changements DDS sont g n r s comme il suit La RAM contient les valeurs d amplitude de tous les points d un cycle 360 de la forme du signal chaque changement d adresse s quentielle correspond une incr mentation de la phase du signal de 360 1024 Au lieu d utiliser un compteur pour g n rer les adresses s quentielles RAM un accumulateur de phase est utilis afin d incr menter la phase GX 1010 59 ADRESSE RAM REGISTRE SE D INCREMENT EE ACCUMULATEUR DE PHASE A chaque cycle d horloge l incr mentation de la phase qui a t charg e dans la phase increment register registre d incr mentation de phase par le CPU est ajout e au r sultat courant dans l accumulateur de phases Les 10 bits les plus significatifs de l accumulateur de phase pilote les lignes d adresse RAM La fr quence des formes des signaux de sortie est alors d termin e par la taille de l incrementation de phase de chaque horloge Si chaque incr mentation est de m me taille alors la fr quence de sortie est constante Si elle change la frequence de sortie change aussi mais avec une continuit de phase Le g n rateur utilise un accumulateur 38 Bit
136. er sur EMF 4 V DC OFFSET 0 8 V FREQ 1 kHz Ce r glage donnera les niveaux standards TTL de 2 4V et 0 4V dans 50Q comme un train d impulsion 1kHz de rapport cyclique 1 1 D placez le curseur dans le champ de Sym trie avec la touche SYM et ajustez la sym trie avec le commutateur rotatif afin de cr er des impulsions avec des marques diff rentes taux d espacement space ratios GX 1010 1 55 56 P riode x sym trie P riode x 1 sym trie gt lt 4 PERIODE Quand la gamme de rapports cycliques utilise cette technique il est limit aux op rations possibles avec le contr le de sym trie 99 1 Pour les tr s petits rapports cycliques une vitesse de r p tition plus basse les syst mes de d clenchement peuvent tre utilis s se reporter la section suivante 6 3 1 Trains d impulsions faible rapport cyclique lls peuvent tre cr s en utilisant le g n rateur de d clenchement interne afin de produire un long intervalle entre les impulsions sachant que chaque impulsion est un cycle simple du g n rateur principal R glez le g n rateur principal sur 10kHz en appuyant sur FREQ 1 0 kHz et diminuez le rapport cyclique 1 99 largeur de impulsion 1us en appuyant sur SYM 1 S lectionnez le menu Trigger D clenchement en appuyant sur EDIT TRIG et r gler SOURCE TGEN c est dire le g n rateur de d clenchement interne La p riode T
137. eriod to lt nrf gt seconds Set triangle function Set trigger mode to lt ON gt or lt OFF gt Set trigger source to lt EXT gt lt MAN gt or lt TGEN gt Set output impedance to lt nrf gt only 50 or 600 are legal GX1010 6 1 6 2 6 3 APPLICATIONS Some examples of the many waveforms that can be generated by this instrument are given in the following sections To make the examples a useful means of gaining familiarity with the generator numeric values have been chosen which are convenient for displaying the waveforms on an oscilloscope To work through the examples connect MAIN OUT from the generator to the input of the scope through a 50Q terminator Default Settings There are many ways of configuring the waveform trigger or modulation settings which might result in the instrument appearing not to work Under these circumstances the simplest means of restoring operation is to recall the default settings by pressing RECALL 0 CONFIRM followed by OUTPUT ON to turn the Main Out on Simple Main Generator Operation With the Main menu displayed press FREQ 1 kHz EMF 1 0 V and select SINE on the FUNCTION keys If the OUTPUT lamp is not lit press ON to turn it on Set the scope to 1V div the timebase to 200us div select DC coupling and observe the waveform Select the other waveforms in turn using the FUNCTION keys and observe the differences between SQUAREWAVE and PULSES the scope trigger may
138. es les derives de phases sont r f renc es partir du ma tre Ainsi 4 g n rateurs r gl s sur la m me fr quence avec 3 esclaves r gl s respectivement sur 90 180 and 270 formeront 4 phases espac es r guli rement du m me signal Mais si le signal de synchronisation a t cha n partir de chaque SYNC vers le EXT TRIG du g n rateur suivant les d phasages se cumulent et chaque esclave doit tre r gl sur la phase 90 afin d obtenir le m me r sultat Les retards dis au hardware deviennent de plus en plus significatifs au fur et mesure que la fr quence augmente et cr ent un retard suppl mentaire de la phase entre le ma tre et les esclaves Mais ces retards peuvent tre annul s en ajustant les r glages de phase des esclaves Le r glage de phase de chaque esclave a un effet sur la phase AUX OUT comme il est d crit dans la section Sortie Auxiliaire Notez quand m me que le r glage de phase dans un but de synchronisation n est pas sujet aux m mes limites de fr quence d pendantes d un signal que AUX OUT Les modes individuels pour le ma tre et les esclaves sont r gl s dans le champ CLOCK BNC du menu SYSt me voir la section R glage Syst me Le maitre est r gl sur CLOCK BNC OUTPUT et tous les esclaves sur CLOCK BNC PHASE LOCK 4 10 4 Synchroniser Une fois les connexions termin es et les r glages des g n rateurs effectu s comme il a t d crit dans les paragraphes pr c dents
139. face GPIB est une option Elle n est pas isol e Les masses signaux GPIB sont connect es la masse instrument L instrument contient les sous groupes suivants SH1 AH1 T6 TEO L4 LEO SR1 RL1 PP1 DC1 DT1 CO E2 L adresse GPIB est r gl e du panneau avant en utilisant le menu I F GX 1010 l 13 4 2 l 14 Fonctions de base Lorsque le g n rateur sera allum pour la premi re fois il sera dot des r glages usine avec la sortie off Les param tres de base peuvent tre r gl s du menu principal comme d crit ci dessous 4 2 1 Param tres du g n rateur principal 4 2 1 1 Fr quence FREQ 10 00000kHz EMF 20 0 Vpp 500 DC 0 00mV 0 00mV SYM 50 0 50 0 Avec le curseur clignotant n importe o sur la premi re ligne du sommaire la fr quence peut tre chang e directement du clavier en entrant le nombre et l unit appropri s ex 1kHz peut tre r gl en entrant 1 kHz ou 0 0 1 MHz ou 1 O O O Hz etc Cependant l affichage montrera toujours l entr e dans l unit la plus appropri e dans ce cas 1kHz Si ce curseur n est pas d j la ligne sup rieure il faut d abord presser la touche FREQ PER Notez que ceci ram ne toujours le curseur au nom du param tre qui peut ainsi alterner entre FREQ et PER par pressions successives d une touche DIGIT ou en tournant le commutateur rotatif PER 100 0000us EMF 20 0 Vpp 50Q DC 0 00mV 0 00mV SYM 50 0 50 0 Quand PER s af
140. fets de cette op ration cessent au moment o l instrument est nouveau adress ou d s qu il re oit un autre caract re de l interface l tat remote est alors remis en mode actif 5 1 1 S lection d adresse et de vitesse Baud Pour une bonne manipulation des instruments il est n cessaire d attribuer une adresse unique a chaque instrument connect a ARC ou GPIB Dans le cas ARC tous doivent tre r gl s sur la m me vitesse de transmission Baud L adresse pour la t l commande des instruments en ce qui concerne les manipulations sur les interfaces ARC et GPIB est r gl e via le menu interface L acc s de celui ci se fait en appuyant sur le bouton I F REMOTE RS232 ARC ADDRESS 05 BAUD RATE 9600 Avec le curseur edit du champ REMOTE l interface s lectionn e peut tre bascul e entre RS232 et GPIB en appuyant alternativement sur les touches DIGIT ou en utilisant le commutateur rotatif Si aucune interface GPIB n a pris place un message d erreur apparaitra si la s lection GPIB est tent e Les r glages resteront a RS232 L adresse est s lectionn e avec le curseur edit dans le champ ADDRESS grace aux touches DIGIT ou au commutateur rotatif Enfin la vitesse de transmission est s lectionn e avec le curseur BAUD RATE grace aux touches DIGIT ou au commutateur rotatif Dans le cas de l utilisation de GPIB toutes les op rations sont faites travers une adresse primaire aucune adresse secondair
141. fiche a la place de FREGQ la fr quence peut tre r gl e en termes de p riodes entrez le nombre et unit ns us ms ou s comme pour la fr quence Notez que la pr cision d entr e d une p riode est limit a 6 digits 7 digits sont affich s mais le dernier est toujours 0 Le g n rateur est toujours programm en termes de fr quence quand une p riode est entr e la fr quence quivalente la plus proche de la r solution fr quence est une conversion 6 digits Si la fr quence est affich e apr s une entr e de p riode la valeur peut diff rer d un chiffre de la valeur attendue a cause de ces consid rations De plus une fois que le r glage est affich comme fr quence la conversion en p riode donnera un quivalent 6 digits de la fr quence 7 digits mais cela peut diff rer d un chiffre de la p riode originale Si le curseur est boug vers la zone num rique tourner le commutateur rotatif qui incr mentera ou d cr mentera la valeur en pas d termin s par la position d dition dans le champ Les touches FIELD bougent le curseur vers les diff rents param tres et les touches DIGIT le bougent dans la zone Ceci est plus amplement expliqu dans la section Principes d dition Enfin avec le curseur dans les zones d unit presser les touches DIGIT ou tourner la molette changera la valeur par dizaine le point d cimal bougera et ou les unit s changeront de fa on appropri e La pr cision 7 digits est maintenue qua
142. field beside the setting If this out of specification setting is changed by reducing the frequency below 30kHz or by changing the waveform then the warning SYMMETRY CHANGED BY FUNC FREC is displayed ERROR messages are shown when an illegal setting is attempted most generally a number outside the range of values permitted In this case the entry is rejected and the parameter setting is left unchanged Examples are 1 Entering a frequency of 100 MHz The error message FREQUENCY PERIOD VAL OUT OF RANGE is shown 2 Entering an EMF of 25V pk pk The error message MAX OUTPUT LEVEL EXCEEDED is shown 3 Entering a DC offset of 20V The error message MAX DC OFFSET EXCEEDED is shown The messages are shown on the display for approximately two seconds The last two messages can be viewed again by pressing the blue EDIT key followed by MSG the 0 number key Each message has a number and the full list appears in Appendix 1 together with some further explanation where the message is not entirely self explanatory The default set up is for all warning and error messages to be displayed and for a beep to sound with each message This set up can be changed on the ERRor menu accessed by pressing the blue EDIT key followed by ERRor key the 2 number key The ERRor menu is shown below ERROR BEEP ON ERROR MESSAGE ON WARNING BEEP ON WARNING MESSAGE ON The flashing cursor can be moved through each of the four editable fi
143. fined state is required by the controller at start up then the command RST should be used to load the system defaults If for any reason an error is detected at power up in the non volatile ram a warning will be issued and all settings will be returned to their default states as for a RST command 5 1 5 Status Reporting This section describes the complete status model of the instrument Note that some registers are specific to the GPIB section of the instrument and are of limited use in an ARC environment 5 1 5 1 Standard Event Status and Standard Event Status Enable Registers These two registers are implemented as required by the IEEE std 488 2 Any bits set in the Standard Event Status Register which correspond to bits set in the Standard Event Status Enable Register will cause the ESB bit to be set in the Status Byte Register The Standard Event Status Register is read and cleared by the ESR command The Standard Event Status Enable register is set by the ESE lt nrf gt command and read by the ESE command Bit 7 Power On Set when power is first applied to the instrument Bit 6 Not used Bit 5 Command Error Set when a syntax type error is detected in a command from the bus The parser is reset and parsing continues at the next byte in the input stream Bit 4 Execution Error Set when an error is encountered while attempting to execute a completely parsed command The appropriate error number will be reported in
144. g the rotary control When Noise is on the lamp beside the last used FUNCTION will go off and no other function including STAIR and ARB can be selected Having set Noise on pressing ESCAPE will return the instrument to the Main menu the FREQuency field will show FREQ WIDEBAND NOISE Normal entries from the keyboard can in fact be made in the frequency field but the new value will not be used until Noise is turned off again Similarly the symmetry setting can be changed while Noise is on but it will have no effect until Noise is turned off again The other parameters on the Main menu can however be changed normally i e amplitude offset and output impedance Noise can also be used in the same way as any other waveform in GATE and AM modes attempting to switch on any other mode will bring up the warning message Operation is illegal here although normal editing of all modes is still permitted HOP The HOP facility allows up to 16 different waveforms to be output in sequence at a rate determined by either the internal timer an external trigger a remote command or by pressing the MAN SYNC key Each waveform can be set to any waveshape frequency amplitude and offset symmetry is the same for every step in the sequence and is defined on the Main menu before HOP is selected Frequency only changes are phase continuous HOP is both edited and controlled from the HOP menu accessed by pressing the blue EDIT key followed by HOP the s
145. gendrer une alt ration de l horloge dans les prises interm diaires dans certaines circonstances D une fa on similaire la connexion de synchronisation de r f rence est du panneau arri re SYNC OUT du maitre vers chacune des entr es EXT TRIG des esclaves L autre possibilit d arrangement est de faire un chainage partir de chaque SYNC OUT vers le EXT TRIG du g n rateur suivant ceci n induit aucun probl me d int grit de donn es mais le fait de cumuler des temps de propagation diminuera la pr cision du d phasage 4 10 3 R glages du g n rateur Les param tres de chaque g n rateur peuvent tre tablis n importe quelles valeurs Ils doivent seulement remplir la condition suivante le quotient des fr quences entre le ma tre et l esclave doit tre rationnel se reporter a la section Principes de Synchronisation Chaque g n rateur peut tre r gl sur n importe quel signal Les relations de phase entre les esclaves et le ma tre sont r gl es individuellement dans les menus Trigger de chaque esclave comme il a t d crit dans la section salve d clench e La convention adopt e dans le mode Synchronis est qu un r glage de phase n gative retarde la sortie de l esclave en respectant le ma tre Par exemple un r glage de phase de 90 retardera l esclave d un quart de cycle tout en respectant le ma tre Si les entr es EXT TRIG de l esclave sont g r es directement partir du maitre alors tout
146. ges Warning messages are given when a setting may not give the expected result e g DC Offset attenuated by the output attenuator when a small amplitude is set the setting is however implemented Error messages are given when an illegal setting is attempted the previous setting is retained The last two warning error messages can be reviewed by pressing EDIT followed by MSG the shifted function of 0 the latest is reported first Warning and error messages are reported with a number on the display only the number is reported via the remote control interfaces The following is a complete list of messages as they appear on the screen In most cases they are self explanatory but where doubt may arise some further explanation is given e Warning Messages 00 No errors or Warns have been reported 07 DC Offset change by Output level 09 Symmetry too wide for func freq 10 Symmetry changed by function freq 11 DC Offset atten by Output level 14 Trigger Generator max res 20us 17 Phase angle change by function freq 20 This instrument is not calibrated 22 Operation is illegal here This warning is used when certain key entries are attempted during operations where they are not permitted Such operations include The instrument is a synchronous slave Edit modes of STAIR and ARB HOP mode selected Noise selected Full explanations of the restrictions will be found in the appropriate operational sections of the manual 23 Mod
147. glages par d faut d un intervalle interne de 1s Notez que chaque chelon peut tre r gl sur une longueur diff rente ou sur un mode diff rent il est donc possible de m langer les chelons de dur e fixe avec des v nements d clenches de fa on externe ou manuelle le compteur interne peut tre r gl de 2ms a 65s avec des incr mentations de 1ms en utilisant le commutateur rotatif ou directement l entr e du clavier se reporter aux consid rations de dur e pour plus d information Avec l intervalle fix sur 0 002s 2ms imposer d autres mouvements dans le sens contraire des aiguilles d une montre au contr le rotatif s lectionnera EXTERNAL puis GX 1010 33 34 MANUAL ils peuvent tre aussi s lectionn s directement a partir du clavier en entrant 1 ms et 0 ms Dans le mode EXTERNAL la s quence est chelonn e a chaque front montant du signal de d clenchement connect a la borne du panneau avant EXT TRIG Dans le mode MANUAL la s quence est chelonn e a chaque fois que la touche MAN SYNC est enfonc e ou qu une commande a distance similaire est donn e Un signal de synchronisation est accessible sur la borne du panneau arri re TRIG SWEEP OUT Au d but de chaque chelon le signal chute suivi par un front montant une fois que la fr quence et la forme du signal aient chang pour le nouvel chelon Mais le front montant a lieu en g n ral avant que le changement d amplitude ou de d calage si sp cifi soi
148. gth because changing them will not affect the waveform If the length of the last active step takes the total number of samples above 1024 then the surplus samples are ignored but the full length is displayed if the last active sample has insufficient samples to bring the total to 1024 then the end of the waveform is filled in with the necessary number of samples at LEVEL 000 Waveform editing forces the symmetry to 50 to simplify entry when edit mode is ended the waveform symmetry will return to that specified on the Main menu 4 7 2 Arbitrary Up to 5 user defined arbitrary waveforms can be down loaded via the RS232 or GPIB interfaces and stored together with a 16 character name in non volatile RAM these waveforms occupy stores 01 to 05 inclusive Stores 06 onwards contain a number of frequently used arbitrary waveforms stored in ROM these may be changed or added to from time to time in response to user requirements Each arbitrary waveform is stored as 1024 points each with a value in the range 512 to 511 i e 10 bit vertical resolution 512 and 511 correspond to 10V and 10V peaks respectively with amplitude on the Main menu set to maximum However the actual waveform played back from the generator can have its amplitude offset and symmetry adjusted as if it was a basic sine square etc waveform The currently recalled arbitrary waveform is selected by pressing the ARB key the lamp beside the ARB key lights to show t
149. has nothing to say The interface code OAH LF is the Universal Command and response Terminator UCT it must be the last code sent in all commands and will be the last code sent in all responses The interface code ODH CR may be used as required to aid the formatting of commands it will be ignored by all instruments Most instruments will terminate responses with CR followed by LF The interface code 13H XOFF may be sent at any time by a listener instrument or controller to suspend the output of a talker The listener must send 11H XON before the talker will resume sending This is the only form of handshake control supported by ARC 5 1 2 4 ARC Interface Control Code List 02H SAM Set Addressable mode 03H UNA Universal Unaddress control code 04H LNA Lock Non Addressable mode control code 06H ACK Acknowledge that listen address received OAH UCT Universal Command and response Terminator ODH CR Formatting code otherwise ignored 11H XON Restart transmission 12H LAD Listen Address must be followed by an address belonging to the required instrument 13H XOFF Stop transmission 14H TAD Talk Address must be followed by an address belonging to the required instrument 18H UDC Universal Device Clear 5 1 3 GPIB Interface When the GPIB interface is fitted the 24 way GPIB connector is located on the instrument rear panel The pin connections are as specified in IEEE Std 488 1 1987 and the instrument complie
150. hat arbitrary mode is selected The ARB edit menu is used to change the currently recalled arbitrary waveform to store new waveforms in non volatile RAM and to name them The arbitrary edit menu is accessed by pressing the blue GX1010 EDIT key followed by ARB When ARB edit is selected the lamp beside the ARB key flashes to show edit mode regardless of whether ARB mode is currently selected to be on or off RECALL ARB NO 14 SINX X CONFIRM TO EXECUTE 4 7 2 1 Recalling Arbitrary Waveforms The default ARB edit menu is shown above With the edit cursor in the store number field each store can be stepped through in turn using the rotary control or direct keyboard entry Each stored waveform from ROM will have a reference name in the second line of the display e g sine x x the user defined waveforms in non volatile RAM will have the names given by the user during the store procedure see next section To recall a particular waveform select the appropriate number and press CONFIRM Once the waveform has been recalled into waveform memory it can be selected by pressing the ARB key and output at the frequency amplitude offset and symmetry defined on the Main menu 4 7 2 2 Storing Arbitrary Waveforms User defined waveforms can be downloaded into non volatile RAM via the RS232 or GPIB interface details are given in the Remote Control section Arbitrary waveforms created from the front panel e g staircase waveforms can be saved
151. he event of the equipment being returned to the METRIX after sales department or to a METRIX local agency carriage shall be payable by the customer The METRIX warranty does not cover the following e Repairs necessitated by misuse of the equipment or use in association with incompatible equipment e Modification of the equipment or any related software without the explicit authorisation of METRIX technical departments e Repairs necessitated by attempts to repair or maintain the product made by a person not approved by the company e Adaptation to a specific application not provided for in the specifications of the equipment or the user manual The contents of this manual must not be reproduced in any form whatsoever without the consent of METRIX Service For problems concerning maintenance spare parts warranty etc please contact your METRIX local agency This organisation will quickly process orders for spare parts and will help you towards a quick repair and calibration service Unpacking Repackaging This equipment has been fully checked out mechanically and electrically before shipping All precautions have been taken to ensure that the instrument arrives at its destination undamaged GX1010 d Caution Should you need to return the generator preferably use the original packaging and indicate the reasons as clearly as possible on an accompanying note er NOTE METRIX products are patented in France and other
152. he instrument to function as a normal RS232 controllable device This mode may be locked by sending the Lock Non Addressable mode control code 04H LNA The controller and instrument can now freely use all 8 bit codes and binary blocks but all interface control codes are ignored To return to addressable mode the instrument must be powered off To enable addressable mode after a instrument has been powered on the Set Addressable Mode control code 02h SAM must be sent This will then enable all instruments connected to the ARC bus to respond to all interface control codes To return to Non Addressable mode the Lock Non Addressable mode control code must be sent which will disable addressable mode until the instruments are powered off Before an instrument is sent a command it must be addressed to listen by sending the Listen Address control code 12H LAD followed by a single character which has the lower 5 bits corresponding to the unique address of the required instrument e g the codes A Z or a z give the addresses 1 26 inclusive while is address O and so on Once addressed to listen the instrument will read and act upon any commands sent until the listen mode is cancelled Because of the asynchronous nature of the interface it is necessary for the controller to be informed that an instrument has accepted the listen address sequence and is ready to receive commands The controller will therefore wait for code 06H ACK before sending any
153. hen sweep edit is selected the lamp beside the SWEEP key flashes to show edit mode regardless of whether sweep operation is selected to be on or off The sweep mode parameters are set up on two pages of the display the flashing edit cursor is moved around each page and between pages by the FIELD and DIGIT keys as described in the Principles of Editing section Return to the Main menu from either page of the edit menu is achieved by pressing the ESCAPE key See also the Squarewave Generation section for information concerning the use of sweep with squarewaves 4 3 2 Connections for Sweep Operation Sweeps are usually used with an oscilloscope or hard copy device to investigate the frequency response of a circuit The MAIN OUT is connected to the circuit input and the circuit output is connected to an oscilloscope or for slow sweeps a recorder To show the markers on the display instrument the rear panel TRIG SWEEP OUT socket should be connected to a second channel an oscilloscope should be triggered off this channel negative edge or the TRIG SWEEP OUT can be connected directly to the external trigger of the oscilloscope if no marker display is required The TRIG SWEEP OUT socket provides a 3 level waveform in sweep mode The output changes from high 4V to low OV at start of sweep and goes high again at end of sweep it can therefore be used as a pen lift signal inverted by the user if necessary if the display device is a chart reco
154. hich means that the response formatter will wait indefinitely if necessary until the instrument is addressed to talk and the complete response message has been sent before the parser is allowed to start the next command in the input queue Commands are sent as lt PROGRAM MESSAGES by the controller each message consists of zero or more lt PROGRAM MESSAGE UNIT gt elements separated by lt PROGRAM MESSAGE UNIT SEPARATOR gt elements lt PROGRAM MESSAGES gt are separated by lt PROGRAM MESSAGE TERMINATOR gt elements which consist of the new line character OAH A lt PROGRAM MESSAGE UNIT SEPARATOR gt is the semi colon character BH A lt PROGRAM MESSAGE UNIT gt is any of the commands in the REMOTE COMMANDS section Responses from the instrument to the controller are sent as lt RESPONSE MESSAGES gt A lt RESPONSE MESSAGE gt consists of one lt RESPONSE MESSAGE UNIT gt followed by a lt RESPONSE MESSAGE TERMINATOR gt GX1010 EXECUTION ERROR ERROR NUMBER IN EXECUTION ERROR QUERY ERROR ERROR NUMBER IN QUERY ERROR STANDARD EVENT STATUS REGISTER 5 2 A lt RESPONSE MESSAGE TERMINATOR is the carriage return character followed by the new line character ODH OAK Each query produces a specific lt RESPONSE MESSAGE gt which is listed along with the command in the REMOTE COMMANDS section lt WHITE SPACE gt is ignored except in command identifiers e g C LS is not equivalent to CLS lt WHITE SPAC
155. hifted function of the 5 key Return to the Main menu is by pressing ESCAPE 4 8 1 Setting Each Waveform Step The HOP menu is shown below With the HOP field set to HOP OFF the edit cursor can be moved around all the editable fields using the FIELD and DIGIT keys in the standard way HOP OFF n 01 01 000s FREQ 10 00000kHz EMF 20 0 Vpp SINE DC 0 00mv LAST 01 The 16 steps are numbered 00 to 15 The step to be edited is selected with the edit cursor in the n field using direct keyboard entries followed by CONFIRM or the rotary control For each step the frequency amplitude and offset are set up having positioned the cursor in the appropriate field exactly as for the Main menu the cursor can be moved directly to the fields of interest by pressing the FREQ PER EMF PD or DC OFFSET keys as appropriate For further information see the Main Generator Parameters section The other parameters of the Main menu symmetry and output impedance are set on that menu and are the same for every HOP waveform The waveshape for each step is selected directly with the standard FUNCTION keys or with the cursor in the edit field to the right of the amplitude display The DIGIT keys or rotary control can be used to step through each choice in turn the corresponding lamp beside the FUNCTION key lights to confirm the selection The currently loaded STAIRcase and ARBitrary waveforms are also included in the selection sequence between RAMP and SINE
156. hout tolerances are given for information only without guarantee Specifications apply at 18 28 C after one hour warm up at maximum output into 50Q Display Data Entry Stored Settings Technical specifications 7 2 1 Functional performance 7 2 1 1 FREQUENCY Range Resolution Accuracy Temperature Stability 7 2 1 2 SYMMETRY Range Resolution 7 2 1 3 WAVEFORMS 20 character x 4 row alphanumeric LCD Keyboard selection of mode waveform etc value entry direct by numeric keys or by rotary control Up to 9 complete instrument set ups may be stored and recalled from battery backed memory 0 1 mHz to 10 MHz All waveforms are available up to 10 MHz However the purity of triangle ramp and multi level squarewave waveforms is not specified above the frequencies indicated in the appropriate WAVEFORM section In Arbitrary mode all waveform points are continuously output up to approximately 27 kHz beyond which they are sampled 0 1mHz 7 digits Typically 10 ppm for 1 year 18 C to 28 C Typically lt 1 ppm C Sine Triangle Ramp 1 to 99 at all frequencies Squarewave Pulse 1 to 99 to 30kHz 20 to 80 to 10MHz 0 1 Sine square positive pulse negative pulse multi level squarewave triangle ramp up ramp down DC ARB and Noise e Sinewave Output level Harmonic Distortion Non harmonic Spurii e Squarewave Output level Rise and Fall Times e Triangle Output level
157. i e the frequency stepping resolution is determined by the number of steps and the sweep span For the fastest sweeps 10ms to 200ms the frequency steps are pre calculated and output at 125us intervals this means that there are 80 discrete steps in a 10ms sweep 160 in a 20ms sweep and so on up to 1600 steps in a 200ms sweep For slow sweeps from gt 200ms up to 999s each frequency step is calculated on the fly and output every 5ms this means that there are 100 steps in a 500ms sweep 200 in a 1s sweep and so on up to nearly 200 000 steps in a 999s sweep Note that at the fastest sweep rates with fewest frequency steps e g 10ms sweep two effects can occur at extremes of frequency span which are not experienced with conventional generators Firstly if the scan is very wide the frequency changes will be quite large at each step if the output is applied to a filter for example the response will be a succession of step change levels with at higher frequencies many cycles of the same frequency at each step Secondly if the begin frequency is less than 800Hz the ramp rate for fast sweeps one or more of the low frequency steps will contain incomplete cycles In part of course these effects can only be created because of the very wide sweeps that can be achieved with DDS techniques analogue generators usually have more restricted capabilities Note also that because the marker pulse duration from the rear panel TRIG SWEEP OUT socket
158. ield Should the symmetry be set outside the permitted range for the selected frequency and waveform combination a warning message will be shown on the display see Warnings and Error Messages section below 4 2 1 7 Warning and Error Messages Two classes of message are displayed on the screen when an illegal combination of parameters is attempted WARNING messages are shown when the entered setting causes some change which the user might not necessarily expect Examples are 1 Changing the EMF from 2 5Volts pk pk to 250mV pk pk brings in the step attenuator if a non zero offset has been set then this will now be attenuated too The message DC OFFSET CHANGE BY OUTPUT LEVEL will be shown temporarily on the screen but the setting will be accepted in this case the actual attenuated offset will be shown in brackets to the right of the set value 2 With the output level set to 10V pk pk increasing the DC offset beyond 5V will cause the message DC OFFSET LEVEL MAY CAUSE CLIPPING The offset change will be accepted producing a clipped waveform and the user may then choose to change the output level or the offset to produce a signal which is not clipped GX1010 Il 17 18 Il 3 With 100kHz squarewave selected increasing symmetry beyond 80 will cause the message SYMMETRY TOO WIDE FOR FUNC FREQ to be displayed The setting will be accepted but the actual symmetry will be limited to 80 as shown in the bracketed
159. in the VALS field both the length and level fields will accept numbers in the range 0 to 100 in 1 steps To edit the staircase or create a new one proceed as follows Move the cursor to the STEP field and use the keyboard or rotary control to select the first step to be changed note that the level of the selected step is dithered during editing to provide a visual check that the correct step is being changed Move the cursor to the LENGTH field and use the keyboard or rotary control to enter the new length for that step in the appropriate units press CONFIRM to enter the value If the AUTO field has been left set at YES the default value the cursor will automatically move to the LEVEL field enter a value in the appropriate units and press CONFIRM again The cursor will move back to the LENGTH field and the STEP field will be incremented by 1 ready for the next entry If AUTO has been set to NO the stepping between LENGTH and LEVEL and the incrementing of the STEP must be done manually The staircase waveform is made up from steps 00 01 02 etc in numeric order up to the step whose length brings the total to 1024 or more samples all these steps including any in the sequence that have zero length will be flagged as ACTIVE beside their step number in the display because changing the LENGTH or LEVEL of any of them will affect the waveform Those steps beyond the last active step will be flagged INACTIVE even if they have a non zero len
160. ion Principes d dition Le retour au menu principal depuis une des deux pages du menu dit se fait en pressant ESCAPE Voir aussi la section G n ration de signaux carr s pour une information concernant l utilisation du balayage avec les signaux carr es 4 3 2 Connexions pour le fonctionnement en balayage Les balayages sont souvent utilis s avec un oscilloscope ou un p riph rique de tra age pour conna tre la r ponse en fr quence d un circuit MAIN OUT est connect e l entr e du circuit et la sortie du circuit est connect e un oscilloscope ou pour les balayages lents un enregistreur Pour montrer les marqueurs sur l instrument l affichage la borne arri re TRIG SWEEP OUT devra tre connect e une seconde voie un oscilloscope sera d clench par cette voie front n gative ou TRIG SWEEP OUT peut tre connect e directement au d clenchement ext rieur de l oscilloscope si aucun affichage de marqueur n est requis La borne TRIG SWEEP OUT fournit un signal 3 niveaux en mode balayage la sortie passe de haut 4V bas en d but de balayage et remonte de nouveau au niveau haut la fin du balayage elle peut ainsi tre utilis e comme un signal ascenseur invers par l utilisateur si n cessaire si l appareil affichage est un enregistreur graphique De plus la sortie fournit des impulsions d environ 1V chaque fr quence marqueur voir la section r glage de port e balayage et mar
161. ions LF e Par d faut rampe escalier arbitraire ainsi que toutes les formes de signaux dont la sym trie est fix e sur autre que 50 sont non filtr es peut tre int ressant de forcer le filtre ON dans certaines circonstances afin d am liorer la qualit de la forme du signal par exemple pour les signaux sinuso daux de haute fr quence qui sont juste un peu asym trique e De m me les signaux carr s impulsions HF et les sorties AUX g n r es partir du comparateur seront am lior es si le filtre est forc sur ON pour filtrer le signal d attaque du comparateur GX 1010 61 62 e Quand le mode de signal carr escalier arbitraires ou LF base fr quence est s lectionn le comparateur est pilot par la forme du signal principal non filtr e A l exception des signaux carr s il est possible d avoir une forme de signal qui ne d passe jamais le seuil du comparateur De cette fa on la sortie HF AUX peut tre tout le temps au niveau haut ou bas Afin d viter cette situation le r glage par d faut d AUX AUTO est le mode LF mais dans ce mode plus la fr quence augmente plus les Jitter sont importants e Le changement de phase entre MAIN et AUX a des fr quences plus hautes seulement possible si le reglage de AUX est sur le mode LF sera diff rent selon que le signal soit filtr ou non Par exemple les signaux carr s impulsion HF provenant du comparateur seront plus d phas s compar s ceu
162. is any of the commands in the REMOTE COMMANDS section Responses from the instrument to the controller are sent as lt RESPONSE MESSAGES gt A lt RESPONSE MESSAGE gt consists of one lt RESPONSE MESSAGE UNIT gt followed by a lt RESPONSE MESSAGE TERMINATOR gt lt RESPONSE MESSAGE TERMINATOR gt is the new line character with the END message NLAEND Each query produces a specific lt RESPONSE MESSAGE gt which is listed along with the command in the REMOTE COMMANDS section lt WHITE SPACE gt is ignored except in command identifiers e g CG LS is not equivalent to CLS lt WHITE SPACE gt is defined as character codes 00H to 20H inclusive with the exception of the NL character OAH The high bit of all characters is ignored The commands are case insensitive Remote Commands The following section lists all commands and queries implemented in this instrument For ease of use commands are grouped to match the display menus The REMOTE COMMAND SUMMARY lists the commands in alphabetical order for reference GX1010 Il 45 Note that there are no dependent parameters coupled parameters overlapping commands expression program data elements or compound command program headers and that each command is completely executed before the next command is started All commands are sequential and the operation complete message is generated immediately after execution in all cases The following nomenclature is used lt pmt
163. is that of the nearest frequency step fast sweep rates with few steps will have wider marker pulses Triggered Burst and Gate In Burst mode a defined number of cycles are generated following each trigger event This mode is edge triggered In Gated mode the generator runs whenever the gating signal is high This mode is level sensitive Both Burst and Gated modes can be controlled by either the internal trigger generator an external trigger input by the front panel MAN SYNC key or by remote control 4 4 1 Internal Trigger Generator The internal trigger generator divides down a crystal oscillator to produce a 1 1 square wave with a period from 0 02ms 50kHz to 200s 005Hz Generator period entries that cannot be exactly set are accepted and rounded up to the nearest available value e g 109ms is rounded to 12ms The generator output is available as a TTL level signal at the rear panel TRIG SWEEP OUT socket In Burst most the rising edge of each cycle of the trigger generator is used to initiate a burst the interval between bursts is therefore 0 02ms to 200s as set by the generator period In Gated mode the output of the main generator is gated on whilst the trigger generator output is high the duration of the gate is therefore 01ms to 100s in step with trigger generator periods of 02ms to 200s GX1010 4 4 2 External Trigger Input External trigger or gate signals are applied to the front panel EXT TRIG input which h
164. itude Modulation d amplitude Interne 28 452 VCA TERME rss ends dane Eege 28 4 6 Modulation de fr quence FSK is 29 4 6 1 R glage de fr quence EE 29 4 6 2 Source de d clenchement ci See NENNEN EE 29 47 AA A A ee tn TT te 30 4 7 1 EE 30 LE 2 PAU Tu 31 4 7 3 Bruit de fond NOISE EE 32 AO Sau HO Plica TR SR ici 32 4 8 1 R gler chaque chelon de la forme du signal 33 4 8 2 D finir la S quence et la dur e 33 4 8 3 Lancer la S quence HOP 34 4 8 4 Consid rations de Dur e eher eege deed eher e dree degen 34 4 8 5 Sauvegarder les R glages HOP ss 35 AS NMOd S d OD ERATIONS Ste Rd lo a ce sol de ne ete 35 4 9 1 Stockage des r glages et Rappels ss 35 4 9 2 Mode de e e sen eones 35 4 10 Synchronisation de plusieurs G n rateurs 36 4 10 1 Principes de Synchronisation EE 36 4 10 2 Connexions pour la Synchronisation 36 e Ee Ee EE ET 37 4104 SNC eneee da 37 5 COMMANDE A DISTANCE eeneg ii id 38 GX 1010 5 Linter acos EEN 38 5 1 1 S lection d adresse et de vitesse Baud eee cece EEN 38 Eu AG cence E 39 5 1 3 Miera EE 42 5 1 4 R glages la mise en route sisi 43 5 1 5 Registres E niet ie tos 44 5 1 6 Formats de commande a distance ARC ss 45 5 1 7 Formats de commande distance GPIB 4eme 46 5 2 Commandes diner encre AN dense net does nd SE ne RU 47 5 2 1 S lection de la fonction eege adidas prete ennemie ane 47 5 2 2 Param tres du g n rateu
165. ixe la fr quence B FSK lt nrf gt Hz Fixe la p riode B FSK lt nrf gt secondes Fixe la source FSK sur lt EXT gt lt MAN gt ou lt TGEN gt Fixe la p riode du g n rateur de d clenchement lt nrf gt secondes Provoque un d clenchement qui aura le m me effet que d appuyer sur la touche MAN SYNC La source de d clenchement MAN REMOTE doit tre s lectionn e en premier La commande Group Execute Trigger GET remplira la m me fonction que TRG 5 2 7 Formes de signaux escaliers et arbitraires STAIR SETSTAIR lt nrf gt ARB lt nrf gt SETARB lt nrf gt lt nrf gt ARBSAV lt nrf gt GX 1010 lt cpd gt Fixe la fonction escalier D finit une nouvelle fonction escalier Il est possible de sp cifier jusqu 16 paires de longueurs et niveaux Les longueurs accept es s talent de 0000 1024 et les niveaux de 512 511 Fixe les fonctions arbitraires D finit une nouvelle fonction arbitraire Il est n cessaire de sp cifier 1024 valeurs pour fixer la forme des signaux chacune ayant un niveau compris entre 512 et 511 Sauvegarde les formes de signaux arbitraires pour garder en m moire lt nrf gt avec le nom lt caract re donn es gt La longueur maximale d un nom est de 16 caract res N B S il est demand de retenir une forme de signal envoy e par une commande SETARB ARBSAV doit tre utilis imm diatement apr s SETARB Si cette action n a pas lieu toute autre
166. l offset r el est affich entre parenth ses comme une valeur non modifiable droite de la valeur de r glage Par exemple la sortie cr te cr te n est pas att nu e par l att nuateur et l offset DC entre parenth ses est le m me que le r glage FREQ 10 00000kHz EMF 2 50 Vpp 50Q DC 150 mV 150 mV SYM 50 0 50 0 Si le niveau sortie est r duit 250 mV cr te cr te ce qui introduit l att nuateur l offset DC r el change par le facteur appropri FREQ 10 00000kHz EMF 250 mp 500 DC 150 mV 15 1mV SYM 50 0 50 0 L afficheur ci dessus montre que Poffset DC est 150 mV mais l offset r el est 15 1mV Notez que Poffset r el prend aussi en compte la vraie att nuation provoqu e par att nuateur utilisant les valeurs d termin es durant la proc dure de calibrage Dans l exemple affich le signal sortie est exactement 250 mV cr te cr te et prend en compte la petite erreur de l att nuateur 20dB l offset est de 15 1mV exactement prenant en compte l effet de ladite att nuation moins que les 20dB nominaux sur l offset de 150mv Chaque fois que l offset DC est modifi par un changement dans le niveau de sortie de cette mani re un message d alerte appara t De la m me fa on parce que l offset DC du signal cr te est limit a 10V pour viter la rupture de signal un message d alerte GX 1010 s affichera Ceci est plus amplement expliqu dans la section Messages
167. l Des pressions r p t es sur chacune des 3 touches donne la s lection de la fonction parmi chacun des 2 ou 3 choix associ s la touche la s lection est indiqu e par une DEL allum e Presser une touche diff rente s lectionne la derni re fonction choisie avec cette touche Ainsi il est possible de choisir entre sinus carr et triangle par simples pressions ou entre impulsions positives et n gatives e Les touches SET permettent une s lection directe des 4 principaux param tres du g n rateur qui sont sur l afficheur pour une entr e des donn es via les touches NUMERIC UNIT e Les touches NUMERIC UNIT permettent l entr e directe de valeur pour le param tre choisi la s lection du param tre est soit directe SET pour les param tres principaux ou en d pla ant le curseur au param tre appropri dans les autres menus Pour r gler une fr quence a 100 Mhz pressez FREQ PER 1 0 0 kHz pour changer une sym trie 40 pressez SYMMETRY 4 0 e Les touches FIELD et DIGIT sont utilis es ensemble avec le commutateur rotatif pour diter des param tres sur le menu pr sent Leur utilisation est mieux expliqu dans la section principes d dition plus bas e Les touches MODE sont utilis es pour connecter le bon mode TRIG PORTE GATEAM etc et choisir le r glage de ces fonctions sp ciales des pressions r pet es sur une touche MODE placera la fonction en on ou off visualis grace au DEL Appuyer su
168. l which can be AC coupled if required at the appropriate level to obtain the modulation depth required If the generator output level is changed the amplitude of the modulating signal will have to be changed to maintain the same modulation depth As with internal AM the maximum output setting of the generator at which clipping is avoided is reduced from 20Vpp EMF to 10Vpp EMF as modulation is increased from 0 to 100 Modulation frequency range is DC to 100kHz The generators amplitude control circuit has four quadrant operation allowing the generator output to be inverted if the external VCA voltage is taken sufficiently negative Suppressed carrier modulation SCM can be achieved by applying a modulating signal with a negative offset between OV and 3V depending on output level setting sufficient to reduce the carrier output to zero It is also possible to modulate a DC level from the generator with a signal applied to VCA IN as follows Set the generator to OHz sine wave on the Main menu and 90 phase on the Trigger menu Select EXT TRIG the default and turn Trigger mode on with the TRIG key but do not apply a trigger signal The MAIN OUT is now set at the peak positive voltage defined by the amplitude setting on the Main menu setting 90 phase on the Trigger menu will give the peak negative voltage Select EXT VCA on the AM edit menu and turn AM on the DC level will now be modulated by the signal applied to the VCA IN socket FSK
169. la synchronisation est activ e en appuyant sur la touche MAN SYNC de chaque esclave l un apr s l autre Une fois synchronis seules les connexions d horloges doivent tre maintenues mais tout changement de r glage d un esclave donc un changement de phase perdra la synchronisation car la m moire du signal est r crite a chaque nouvelle phase etc et une resynchronisation sera n cessaire GX 1010 37 38 COMMANDE A DISTANCE Interfaces Les sections suivantes pr sentent en d tail l utilisation de l instrument via GPIB et ARC Dans les cas o le fonctionnement est identique aucune distinction ne sera faite entre les deux Par contre s il existe des diff rences elles seront expliqu es en d tail dans les sections correspondantes ou dans certains cas dans des sections ARC et GPIB part Il suffit donc de lire les sections principales puis les sections sp cifiques se r f rant l interface vous int ressant Quand il est allum l instrument est dans l tat local avec la DEL REMOTE teinte Dans cet tat toutes les op rations clavier sont accept es Dans le cas o l instrument est adress en mode de r ception et si une commande est re ue l instrument entre dans l tat remote et la DEL REMOTE s allume Dans cet tat le clavier est verrouill et seules les commandes distance fonctionnent Pour revenir l tat local il suffit d appuyer sur EDIT qui sert galement de touche LOCAL mais les ef
170. les minuscules pour les mn motechniques de commande et il est facile de les m langer Les codes ASCII en dessous de 20H espace sont r serv s pour la commande d interface 5 1 2 3 Codes de contr le de l interface ARC Tous les instruments qui doivent tre utilis s sur le bus ARC utilisent le groupe de codes de contr le d interface suivant Les codes entre OOH et 1FH qui ne sont pas indiqu s ici comme ayant une signification particuli re sont r serv s en vue d utilisation ult rieure et il n en est pas tenu compte Des codes de contr le de m lange d interface l int rieur des commandes de l instrument ne sont pas admissibles sauf comme indiqu ci dessous pour les codes CR et LF et pour les codes XON et XOFF La premi re fois qu on allume un instrument il entre automatiquement en mode Non Addressable Dans ce mode l instrument n est pas adressable et il ne r pond pas aux commandes d adresse Ceci permet l instrument de fonctionner en tant que dispositif RS232 habituel contr lable On peut bloquer ce mode en transmettant le code de contr le de mode Lock Non Addressable 04H LNA Le contr leur et l instrument peuvent maintenant utiliser librement tous les codes de 8 bits et les blocs binaires mais tous les codes de contr le d interface sont ignor s Eteindre l instrument pour le faire retourner en mode adressable Il faut transmettre le code de contr le Set Addressable Mode 02h SAM pour activer le mode adressable apr
171. leur de l angle de phase hors limite 118 G n rateur de d clenchement fix par le sinus am GX 1010 69 70 119 121 126 127 128 134 135 136 Valeur de profondeur de mode hors limite Erreur du syst me ram pile d charg e Temps de balayage trop long Temps de balayage trop court Aucune interface disponible Num ro d tape HOP ill gal Valeur de temps HOP hors limite Impossible de verrouiller en phase avec le maitre es Messages d erreur Commande distance uniquement Les op rations suivantes concernent uniquement les op rations a distance 129 130 131 132 133 num ro de m moire demand ill gal valeur d octet en dehors des valeurs 0 255 Valeur ill gale dans les donn es en escalier stockage ARB illegal Valeur ill gale dans les donn es arbitraires GX 1010 ANNEXE 2 R glages usine par d faut Les r glages usine par d faut sont tous list s ci dessous Ils peuvent tre rappel s en appuyant sur Recall 0 Confirm ou avec la t l commande RST e Param tres du menu principal Fr quence Sortie Zsortie DC D calage Sym trie 10kHz 20V cr te cr te EMF 50Q OV 50 Output OFF e Param tres de d clenchement Source TGEN D compte de salve Phase e Param tres des portes Source TGEN e Param tres FSK Freq A Freq B Source TGEN e Param tres AM Source TGEN Profondeur Mod Interne Signal Mod Interne e Param tres STAIR
172. ll screwdriver or trimmer tool through the adjustment aperture marked LCD and rotate the control for optimum contrast 4 1 4 Keyboard The keys can be considered in 7 groups e FUNCTION keys permit direct selection of the waveform function Repeated presses of each of the 3 keys steps the function selection through each of the 2 or 3 choices associated with that key the current selection is indicated by the illuminated lamp Pressing a different key selects the function last selected with that key In this way it is therefore possible to select between for example sine square and triangle with single key presses or between positive pulses and negative pulses etc e SET keys permit direct selection of the four main generator parameters shown on the Main menu of the display ready for value entries from the NUMERIC UNIT keys e NUMERIC UNIT keys permit direct entry of a value for the parameter currently selected parameter selection is either directly by the SET keys for the main parameters or by moving the cursor to the appropriate parameter in other menus Thus to set a new frequency of 100kHz for example press FREQ PER 1 0 0 kHz or to change symmetry to 40 press SYMMETRY 4 0 e FIELD and DIGIT keys are used together with the ROTARY CONTROL to edit parameters on the current menu Their use is explained more fully in the Principles of Editing section below e MODE keys are used both to directly switch the respective
173. longueur de cycle Quand les valeurs sont r gl es sur ABSolute dans le champ VALS le champ LENGTH longueur acceptera des nombres situ s entre 0000 et 1024 la longueur d chantillon du cycle et le champ LEVEL acceptera des valeurs entre 512 et 511 c est dire une r solution 10 bits de cr te a cr te 512 et 511 correspondent des cr tes de 10V et 10V respectivement avec l amplitude du menu Main r gl e au maximum mais notez que la tension cr te cr te sera d termin e par le r glage d amplitude actuel Quand la valeur est r gl e sur MAX dans le champ VALS les champs longueur et niveau accepteront des nombres entre 0 et 100 avec des chelons de 1 Pour diter l escalier ou pour en cr er un nouveau proc dez comme suit D placer le curseur vers le champ STEP et utiliser le clavier ou le contr le rotatif pour s lectionner le premier chelon a changer notez que le niveau de l chelon s lectionn est changeant pendant l dition afin de v rifier de fa on visuelle si le bon chelon est entrain d tre chang D placez le curseur vers le champ LENGTH et utilisez le clavier ou le contr le rotatif pour entrer la nouvelle longueur pour cet chelon appuyez sur CONFIRM pour entrer la valeur Si le champ AUTO est rest YES la valeur par d faut le curseur se d placera automatiquement dans le champ LEVEL entrez une valeur dans les unit s appropri es et appuyez sur CONFIRM une nouvelle fois Le curseur revi
174. lows Select GATE edit mode and set the SOURCE to MAN REMOTE Exit edit mode and turn on GATE mode with the GATE key Provided that GATE mode is not triggered the MAIN OUT will now remain at the level set by the DC Offset control On the main menu set the output level to 1Vpp this ensures that the software does not warn of clipping output level too high and that the output attenuator is not switched in which would also attenuate the DC Offset With the cursor in the DC Offset field the MAIN OUT can now be adjusted over the range 10V EMF 4 2 1 6 Symmetry Pressing the SYMMETRY key moves the flashing edit cursor directly to the symmetry numeric field on the bottom line of the display This is the only field that can be edited the bracketed field on the right hand side shows the actual symmetry which might differ from that set if the set value is outside that permitted for the selected frequency and waveform combination see Specification section For example in the display below the frequency is set to 100kHz and a squareware is selected FREQ 100 0000kHz EMF 20 0 Vpp 500 DC 0 00mV 0 00mV SYM 90 0 80 0 The symmetry is set to 90 but the actual symmetry is 80 the limit for squarewaves and pulse waveforms above 30kHz The flashing cursor can be moved within the field using the DIGIT keys turning the rotary control will then increment or decrement the setting in steps determined by the position of the cursor in the f
175. m generation is in Low Frequency mode see Waveform Generation Options section this ultimately limits how narrow a pulse can be generated at very low repetition rates 6 3 2 Multiple Pulses Multiple pulse trains are obtained by using the same trigger set up as above but with the burst count set to the desired number of pulses GX1010 6 4 MAIN p SC MAIN PER PERx X SYM TGEN PERIOD gt 1 SYM gn Set TGEN to 1 00ms again 1kHz and the burst count to 2 this will give the waveform shown The pulse width and interval between successive pulses is determined by the main generator frequency and symmetry the pulse width will be PER x SYM and the pulse low time will be PER x 1 SYM The repetition rate of the bursts remains determined by the TGEN period Variable Transition Pulse Waveforms The half cycle triggered burst capability can be used to produce square waves with a variety of different edge shapes Three examples are shown one with straight slew limited transitions and two with sinusoidal transitions where different start stop phase settings give quite different effects 6 4 1 Slew limited transitions The edge of slew rate limited pulses are straight lines produced by half cycles of the main generator triangle wave The interval between the edges is again defined by the trigger generator MAIN WAN PER PER a x SYM gt gt 1 SYM lt
176. meters ARB Parameters Noise Hop Parameters Frequency Output Zout DC Offset Symmetry Source TGEN Burst Count Phase Source TGEN Freq A Freq B Source TGEN Source TGEN Internal Mod Depth Internal Mod Wave 10kHz 20Vpp EMF 50Q OV 50 Output OFF EXT ims 0 EXT ims 10kHz 10MHz EXT ims EXT VCA 1ms 30 Square Symmetrical 3 level squarewave maximum amplitude Default waveform from store 14 i e sinx x Begin frequency End frequency Marker frequency Mode Law Ramp time Trig Source Noise Off Hop Off 100kHz 10MHz 5MHz Being to End Log 50ms Continuous All parameters are unaffected by Recall O or RST except Last Step which is set to 01 68 Il GX1010 GX1010 Il 69 Accessories 64 Accuracy 4 Address 37 AM 4 10 25 27 29 47 61 Arbitrary 4 30 60 ARC 37 38 39 40 44 AUX OUT 10 12 19 36 62 B Basic functions 14 Baud 37 Burst 5 24 25 C Calibration 7 CE 10 CLOCK 10 12 35 62 CONFIRM 10 Cursor 34 DC 15 17 32 DDS 4 9 55 56 DIGIT 10 Display 10 E M C 63 EDIT 10 Editing 10 EMF PD 32 Error Messages 17 ESCAPE 10 EXT TRIG 12 FIELD 10 Filter 20 FREQ PER 14 Frequency 14 21 29 32 59 FSK 4 25 28 29 47 58 61 Function 45 G GATE 5 10 17 24 25 26 29 46 60 70 Il INDEX GPIB 5 9 13 40 41 44 H HF AU
177. mode is changed such that the best overall performance is achieved across the whole generator frequency range see the DDS Principles section for further details of the 30kHz changeover In addition triangle ramp staircase and arbitrary waveforms can be inhibited from being set above 100kHz to ensure that they are not used accidentally at frequencies where the waveshape is noticeably deteriorating In all cases however the default choice can be overridden by the user by changing the setting on the OPTions menu SQWAVE GEN AUTO FILTER AUTO AUX AUTO FSTOP ON SWEEP TGEN OUT AUTO The OPTions edit menu shown above is selected by pressing the blue EDIT key followed by OPTN the shifted function of 1 The following descriptions grouped together in this section for reference convenience should be read in conjunction with the main explanations of the appropriate parameter elsewhere in this manual Each parameter is altered by moving the edit cursor to the appropriate field with the FIELD keys and using the DIGIT keys or rotary control to change the setting 4 2 3 1 Squarewave Generation In LOW FREQency mode the squarewave and pulse waves are generated digitally in this way precision squarewaves can be generated down to very low frequencies without the edge uncertainty that would be associated with conventional ramp and comparator techniques Above approximately 27kHz clock frequency 27 487MHz 1024 the waveforms are sampled and the 1 cl
178. mplitude utilisant le g n rateur d clenchement interne comme source de modulation dans laquelle la profondeur de modulation est exprim e en pourcentage et la profondeur de modulation constante est maintenue quand l amplitude du g n rateur principal porteur varie e Le mode VCA Amplitude contr l e par Tension dans lequel l amplitude du g n rateur principal est directement proportionnel la tension du signal modulant externe appliqu e la borne VCA IN du panneau arri re La modulation porteuse supprim e SCM fonctionne dans ce mode le mode AM est activ et d sactiv par pressions altern es de la touche AM la DEL c t de la touche s allume quand elle est activ e Les param tres sont tous r gl s du menu AM qui est choisi en pressant EDIT puis AM Quand AM est choisi la DEL c t de AM clignote pour montrer que la fonction est dit e sans regard et seul le mode AM est activ ou d sactiv SOURCE EXT VCA TGEN 1 00ms 1 000kHz INT MOD DEPTH 030 INT MOD SQUARE GX 1010 27 28 4 5 1 Modulation d Amplitude Modulation d amplitude Interne Avec le curseur dans la zone SOURCE du menu AM les touches DIGIT ou la molette permettent le passage de source entre EXT VCA et TGEN 4 5 1 1 Fr quence de Modulation S lectionnez TGEN dans la zone source et d placez le curseur vers la zone TGEN pour r gler la p riode du g n rateur d clenchement interne la source de modulation p
179. n lt nri gt numeric format The syntax of the response is lt nr1 gt lt rmt gt Il 49 5 3 50 Il STB WAI Returns the value of the Status Byte Register in lt nr1 gt numeric format The syntax of the response is lt nr1 gt lt rmt gt Wait for operation complete true As all commands are completely executed before the next is started this command takes no additional action 5 2 12 Miscellaneous Commands IDN TST Returns the instrument identification The exact response is determined by the instrument configuration and is of the form lt NAME gt lt model gt 0 lt version gt lt rmt gt where lt NAME gt is the manufacturer s name lt MODEL gt defines the type of instrument and lt VERSION gt is the revision level of the software installed The generator has no self test capability and the response is always O lt rmt gt 5 2 13 Phase Locking Commands TRG CLOCKBNC lt cpd gt ABORT Executes a trigger which will have the same effect as pressing the MAN SYNC key GPIB Group Execute Trigger command GET will perform the same function as TRG Set clock bnc mode to lt OUTPUT gt lt INPUT gt or lt SLAVE gt phase lock Abort on unsuccessful phase locking operation If no operation was in progress the command is ignored If an operation is aborted then error 136 is placed in the execution error register Remote Command Summary ESE lt nrf gt ESE ESR IDN IST LR
180. n r e de fa on a tre faible quand la vitesse de r p tition est tr s basse 6 3 2 Impulsions Multiples Les trains d impulsions multiples sont obtenus en utilisant les m mes r glages de d clenchement que ci dessus mais en r glant le d compte de salve sur le nombre d impulsions d sir es PER PER PPANC e PRINC SYM 1 SYM PERIODE TGEN gt Fixer TGEN 1 00ms 1kHz et le d compte de salve 2 ceci donnera le signal ci dessus La largeur de l impulsion et l intervalle entre les impulsions successives sont d termin es par la fr quence et la sym trie du g n rateur principal la largeur de l impulsion sera PER x SYM et la p riode lente de l impulsion sera de PER x 1 SYM La vitesse de r p tition des salves est toujours d termin e par la p riode TGEN Impulsion transition variable La capacit de salve enclench e demi cycle peut tre utilis e pour cr er des signaux carr s avec diff rentes formes de fronts Trois exemples suivent l un avec des fonds lin aires et les deux autres avec des fonds sinuso daux o les divers r glages de phase start stop donnent des effets diff rents 6 4 1 Transitions vitesse limit e Les fronts des impulsions vitesse limit e sont des lignes droites cr es par des demi cycles des signaux triangulaires du g n rateur principal L intervalle entre les fronts est nouveau d fini par le g n rateur de d clenchement PER PER PRI
181. n d une rallonge doit se faire avec une prise terre Tension d alimentation 3 2 1 Alimentation partir du r seau Installation V rifiez la tension d alimentation l arri re de l appareil par rapport a votre alimentation Attention TOUTE OPERATION POUR MODIFIER LA TENSION DE FONCTIONNEMENT DOIT ETRE REALISEE PAR DU PERSONNEL QUALIFIE POUR LA MAINTENANCE ET NON PAR L UTILISATEUR Dans le cas d un changement de tension d alimentation proc dez comme suit 1 D connectez l instrument de toute source d alimentation 2 Apr s avoir enlev les vis retenant le boitier retirez la partie haute du boitier 3 Changez les connexions du transformateur comme suit Pour un fonctionnement 230V connectez le fil brun la broche 15 Pour un fonctionnement 115V connectez le fil brun la broche 14 Pour un fonctionnement 100V connectez le fil brun la broche 13 4 Remontez l instrument en suivant les op rations ci dessus dans l ordre inverse 5 Changez la r f rence de tension sur le panneau arri re pour montrer le nouveau r glage afin d tre conforme avec la norme de s curit 6 Changez le fusible avec un correspondant au bon calibre 230 V 115V 100 V OV Etalonnage Calibration Tous les param tres peuvent tre calibr s sans qu il soit n cessaire d ouvrir le bo tier le g n rateur propose un calibrage boitier ferm Tous les ajustements sont faits de fagon GX 1010 num rique avec des con
182. n outil adapt la g n ration de formes des signaux hautement complexes De plus de nombreuses formes de signaux complexes sont pr d finies dans la ROM ceci incluant les formes usuelles telles sinx x signal sinuso dale d croissance exponentielle etc D autres formes de signaux seront ajout es dans la biblioth que la demande des clients Wobulation Tous les signaux peuvent tre balay s sur la totalit de la gamme de fr quence un temps variant de 10 ms 15 minutes La phase est continue devant le balayage Le balayage peut tre lin aire ou logarithmique unique ou continu Les balayages uniques peuvent tre d clench s de la face avant de l entr e d clenchement ou des interfaces num riques Deux marqueurs de balayage sont fournis AM La modulation d amplitude est disponible pour toutes les formes de signaux et peut varier de 1 100 Une source AM interne est incorpor e La modulation peut galement tre contr l e partir d un g n rateur ext rieur FSK La manipulation de d viation de fr quences FSK Frequency Shift Keying permet une commutation phase coh rente entre deux fr quences choisies un taux d fini par le signal source de commutation GX 1010 2 6 2 7 2 8 2 9 2 10 Le taux peut tre r gl en interne du continu a 50kHz ou du continu a 1MHz en externe D clenchement par salve ou mode porte GATE Toutes les formes de signaux sont dis
183. nd la valeur est d cr ment e jusqu ce que la limite de r solution de 0 1mHz de l instrument soit atteinte les valeurs qui auraient au moins des bits lt 0 1mHz sont tronqu s avec les d cr ments suivants et la pr cision est perdue quand le nombre est incr ment de nouveau 4 2 1 2 Niveau de sortie La deuxi me ligne du menu principal permet au niveau de sortie d tre r gl en termes d EMF tension circuit ouvert ou PD diff rence de potentiel dans une charge adapt e ou dBm R f rence l imp dance de la source sp cifi e EMF et PD peuvent tre r gl es en volts cr te cr te Vpp ou volts efficace Vrms Notez que dans les deux cas les vraies valeurs cr te cr te ou rms sont montr es pour la forme de signal choisi m me arbitraire GX 1010 Cependant dans le cas Vrms le d calage DC voir prochaine section est ignor dans le calcul et doit tre pris en consid ration par l utilisateur si le d calage DC n est pas z ro FREQ 10 00000kHz EMF 20 0 Vpp 50Q DC 0 00mV 0 00mV SYM 50 0 50 0 La forme d sir e de l affichage du niveau de sortie peut tre choisi pendant que le curseur est dans la zone en choisissant les options avec les touches DIGIT ou la molette amenez le curseur a la zone d sir e si n cessaire en pressant EMF PD ou en utilisant les touches FIELD Avec la forme de param tre choisie la valeur est entr e comme un nombre suivi d unit ex 100mv peut tre
184. nections for SyNCHTONISA ION cimil 36 GX1010 410 3 Generator EE 36 410 4 SYMCMPOMSING EE 36 5 REMOTE OPERATION 0 37 By Vig ue 37 5 1 1 Address and Baud Rate Selection is 37 er EI 37 o RE Eeer EE 40 5 1 4 Power OM Settings E 42 DS A a inka ty dad ee ee beats de ie tant 42 5 1 6 ARG Remote Command BS eg CT 44 5 1 7 GPIB remote command formats ur dee Ee EE e 45 5 2 Remote un E EEN 45 5 2 1 PUNCION Selecionar 46 5 2 2 Main Generator Parameters do 46 5 2 3 Sweep Parameters date en tt dt dad ne 46 5 2 4 Trigger and Gale in nent tak Heche 47 5 25AM NE LOS LL Le 47 5 2 6 EE 47 5 2 7 Staircase and Arbitrary WaveforMS kk 48 5 2 8 Waveform Generation Options is 48 O EE Ee 48 5 2 10 System Commands renier en lee ne lee en Rene 48 E EE COMMUN ANAS lite 49 5 2 12 Miscellaneous Commands isc cdi 50 5 213 Phase e tee Beet EE 50 5 3 Remote Command Summary re ti 50 EE Rei wiel LEE 53 6 1 Default Settings Mon raie RM Re Re enna eae elie 53 6 2 Simple Main Generator Operation ss 53 6 3 PUSO Trauma Ee ege ee Een ee EE ege EE EE EE 53 6 3 1 Low Duty Cycle Pulse Trains sans EE EE dre ends see een 54 6 3 2 Mulliple Pul eS e ia 54 6 4 Variable Transition Pulse Wavelomms EEn 55 6 4 1 Slew limited transitions aid 55 6 4 2 Band limited GE 55 643 Pulses witht e ee a SAS AO 56 6 5 DDS Operation and Further Waveform Consideraions 56 GX1010 6 5 1 DDS OPI DEE 56 6 5 2 Further Wavefo
185. ngle or continuous Sweep Width From 0 1 mHz to 10 MHz in one range Phase continuous Independent setting of the start and stop frequency Sweep Time 10ms to 999s 3 digit resolution Markers Two variable during sweep Available at the rear panel TRIG SWEEP OUT socket Sweep Trigger source The sweep may be free run or triggered from any of the following sources Internal from keyboard External from EXT TRIG input or remote interface e Amplitude Modulation Carrier frequency From 0 1mHz to 10 MHz Carrier waveforms All Depth Variable 0 to 100 typical resolution 1 Internal source 1 kHz fixed sinewave or 0 005 Hz to 50 kHz squarewave External See VCA In e Frequency Shift Keying FSK Phase coherent switching between two selected frequencies at a rate defined by the switching signal source Carrier frequency From 0 1mHz to 10 MHz Carrier waveforms All Switch repetition rate dc to 50 kHz internal dc to 1 MHz external Switching signal source Internal from keyboard or trigger generator External from EXT TRIG input or remote interface e Start Stop Phase Carrier frequency 0 1 mHz to at least 1MHz Carrier waveforms All Range 360 to 360 degrees Resolution 1 degree Accuracy Typically 1 degree to 30 kHz e Trigger Generator Internal source 0 005 Hz to 50 kHz squarewave adjustable in 20us steps 3 digit resolution Available for external use from TRIG SWEEP OUT socket 7 2 1 5 OUTPUT
186. nt la valeur par 10 chaque pression les unit s changent automatiquements Le commutateur rotatif ROTARY CONTROL fonctionne comme suit Avec le curseur dans un champ quelconque tourner la commande agit comme presser les touches DIGIT Avec le curseur positionn n importe o dans un champ num rique param tre tourner la commande augmentera ou baissera la valeur la taille du pas est d termin e par la position du curseur dans le champ num rique Ainsi pour FREQ 1 00000 MHz tourner la commande changera la fr quence de 1kHz L affichage suivra le changement de fr quence Ceci d terminera tour tour le r glage le plus bas et le plus haut qui peut tre obtenu en tournant la commande Dans cet exemple ci dessous la plus basse fr quence qui peut tre r gl e en tournant la commande est 1 kHz affich e FREQ 1 000000 kHz C est la limite car pour afficher une fr quence plus basse l affichage devrait se placer sous 1kHz pour FREQ xxx xxx Hz dans lequel le chiffre le plus signifiant repr sente 100 Hz l incr ment d 1 kHz serait perdu Si cependant le r glage de d part avait t FREQ 1 000000 MHz pour un incr ment de 100Hz l affichage serait pass en 1 kHz FREQ 900 0000 Hz et pourrait tre d cr ment jusqu a FREQ 000 0000 Hz sans perdre l incr ment 100 Hz Tourner rapidement la molette incr mentera plusieurs fois la valeur GX 1010 l 11 1 12 4 1 6 Connexions Panne
187. nted subsets are SH1 AH1 T6 TEO L4 LEO SR1 RL1 PP1 DC1 DT1 CO E2 The GPIB address is set from the front panel using the I F menu GX1010 Il 13 4 2 14 Il Basic functions 4 2 1 Main Generator Operation When first switched on and at all subsequent power ups unless specified otherwise on the SYStem menu the generator will be set to the factory defaults with the output off The basic parameters can be set from the Main menu as described below 4 2 1 1 Frequency FREQ 10 00000kHz EMF 20 0 Vpp 500 DC 0 00mV 0 00mV SYM 50 0 50 0 With the flashing edit cursor anywhere on the first line of the Main menu the frequency can be changed directly from the keyboard by entering the number and appropriate units only e g 1kHz can be set by entering 1 kHz or O O 1 MHz or 1 0 O 0 Hz etc However the display will always show the entry in the most appropriate engineering units in this case 1 000000 kHz If this cursor is not already in a top line field it is first necessary to press the FREQ PER key before making the number and unit entry Note that this always returns the cursor to the parameter name field which can then be alternated between FREQ and PERiod with successive presses of either DIGIT key or by turning the rotary control PER 100 0000us EMF 20 0 Vpp 50Q DC 0 00mV 0 00mV SYM 50 0 50 0 When PER shows in the display instead of FREQ the frequency can be set in terms of a period en
188. nts de pas en niveaux avec dans les hautes fr quences beaucoup de cycles la m me fr quence chaque pas Deuxi mement si la fr quence de d but est inf rieure de 800HZ la vitesse de rampe pour les balayages rapides un ou plusieurs pas basse fr quence auront des cycles incomplets Ces effets ne peuvent seulement tre cr s en partie cause des balayages tr s larges qui peuvent tre faits avec les techniques DDS les g n rateurs analogiques ont des capacit s plus restreintes Notez aussi que puisque la dur e d impulsion jitter de la borne TRIG SWEEP OUT du panneau arri re est celle de l chelon fr quence le plus proche les hautes vitesses de balayage avec peu d chelons auront des impulsions jitter plus larges Salve d clench e et porte GATE En mode Salve un nombre d fini de cycles est g n r suivant chaque v nement d clencheur Ce mode est front d clench En mode Porte GATE le g n rateur tourne m me si le signal porte est haut Ce mode est sensible au niveau Les mode Salve et Porte GATE peuvent tre contr l s par le g n rateur d clenchement interne une entr e d clencheur externe par la touche MAN SYNC du panneau avant ou par t l commande GX 1010 4 4 1 G n rateur de d clenchement interne Le g n rateur d clenchement interne part d un oscillateur quartz pour produire un signal carr e 1 1 avec une p riode de 0 02ms 50kHz 200s 0
189. nu lt EXT gt externe ou lt MAN gt manuel Fixe le temps de balayage a lt nrf gt secondes R gle le mode de sortie bnc balayage tgen sur lt AUTO gt lt SWEEP gt ou lt TGEN gt Fixe la sym trie lt nrf gt Fixe la p riode du g n rateur du d clenchement lt nrf gt secondes R gle la fonction triangulaire R gle le mode d clenchement sur lt ON gt ou lt OFF gt R gle la source de d clenchement sur lt EXT gt lt MAN gt ou lt TGEN gt Fixe l imp dance de sortie lt nrf gt seuls 50 ou 600 sont permis GX 1010 6 1 6 2 6 3 APPLICATIONS Certains exemples des nombreuses formes de signaux pouvant tre g n r s par cet instrument sont donn s dans les sections suivantes Afin que les exemples aident a rendre l utilisation du g n rateur plus familier des valeurs num riques appropri es ont t choisies pour avoir une pr sentation des signaux sur un oscilloscope Afin de travailler sur les exemples connectez le MAIN OUT du g n rateur l entr e de Poscilloscope avec une terminaison 50Q R glages par d faut Avec certaines fa ons de configurer les r glages de d clenchement ou de modulation de signal l instrument peut sembler ne plus fonctionner Dans ce cas la fa on la plus simple de r tablir l op ration est de rappeler les r glages par d faut en appuyant sur RECALL 0 CONFIRM suivi par OUTPUT ON pour activer la sortie Main Out Op ration Simple du G n
190. nu HOP auquel on acc de en appuyant sur la touche bleue EDIT suivie de HOP touche 5 Pour revenir au menu principal appuyez sur ESCAPE 4 8 1 R gler chaque chelon de la forme du signal Le menu HOP est montr ci dessous Quand le champ HOP est r gl sur HOP OFF le curseur peut se d placer travers tous les champs et tre dit grace aux touches FIELD et DIGIT HOP OFF n 01 01 000s FREQ 10 00000kHz EMF 20 0 Vpp SINE DC 0 00mv LAST 01 Les 16 s quences sont num rot s de 00 a 15 Les s quences devant tre dit es sont s lectionn es avec le curseur dans le champ n grace au clavier ou au commutateur rotatif suivis de CONFIRM Pour chaque s quence la fr quence l amplitude et le d calage sont fix s avec le curseur positionn dans le champ appropri exactement comme dans le menu principal le curseur peut tre d plac directement vers les autres champs en appuyant sur les touches FREQ PER EMF PD ou DC OFFSET Pour de plus amples informations se reporter la section Param tres du G n rateur Principal Les autres param tres du menu principal la sym trie et l imp dance de sortie sont r gl s dans ce menu et sont les m mes pour chaque signal HOP La forme du signal pour chaque chelon est s lectionn e directement avec les touches standards FUNCTION ou grace au commutateur dans le champ situ a droite de l affichage de l amplitude Les touches DIGIT ou le commutateur rotatif peuvent tre
191. o a phase increment of the waveform of 360 1024 Instead of using a counter to generate sequential RAM addresses a phase accumulator is used to increment the phase 38 Bit RAM ADDRESS 10 Bit PHASE SES A A INCREMENT REGISTER PHASE ACCUMULATOR On each clock cycle the phase increment which has been loaded into the phase increment register by the CPU is added to the current result in the phase accumulator the 10 most significant bits of the phase accumulator drive the RAM address lines The output waveform frequency is now determined by the size of the phase increment at each clock If each increment is the same size then the output frequency is constant if it changes the output frequency changes but with phase continuity The generator uses a 38 bit accumulator and a clock frequency which is 2 x 10 27 487MHz this yields a frequency resolution corresponding to the smallest phase increment of fcLk 2 0 1mHz Only the 10 most significant bits of the phase accumulator are used to address the RAM At a waveform frequency of fCLK 1024 26 84kHz the natural frequency the RAM address increments on every clock At all frequencies below this i e at smaller phase increments one or more addresses are output for more than one clock period because the phase increment is not big enough to step the address at every clock Similarly at waveform frequencies above the natural frequency the larger phase increment cause
192. ock 36ns uncertainty introduces edge jitter which becomes increasingly significant at higher frequencies In HIGH FREQuency mode the squarewave and pulses are derived from the output of a comparator driven by the DDS generated sinewave The sinewave is by default filtered and jitter free the high frequency squareware and pulse waveforms are thus jitter free too In AUTO mode the default the generation of squarewave and pulse waveforms is automatically switched from low to high frequency mode when the frequency exceeds 30kHz However when these waveforms are used in sweep and FSK modes over a frequency range which includes the 30kHz changeover point the generation mode will not change even though AUTO is selected Instead the mode in use before sweep or FSK are turned on is maintained across the frequency range this can of course be overridden by selecting either high or low frequency mode on the Options menu as described above 4 2 3 2 Filter The generator contains a 7 stage elliptical filter which exhibits a sharp cut off beyond the maximum generator frequency reducing intermodulation spurii and clock harmonics to a very low level With the default condition of FILTER AUTO set on the Option menu the filter is switched in automatically for sine triangle high frequency squarewave and high frequency pulse waveforms although the squarewave and pulse waveforms themselves do not pass through the filter the filter is automatically switch
193. oes not change the HOP set up or any of the other set ups stored in memories 1 to 9 4 9 2 System Settings This section deals with a number of system settings which can be changed to suit the user These are the cursor style the power up setting and rotary control status In addition the function of the rear panel CLOCK IN OUT socket is set from this menu CURSOR CHAR 0 DIAL UNLOCKED POWER UP DEFAULTS CLOCK BNC OUTPUT GX1010 4 10 4 9 2 1 Cursor Style The edit cursor style can be selected with the cursor in the CURSOR CHAR field The default style is to alternate between the screen character and underline the alternatives are a solid rectangle an open rectangle and a blank Use the rotary control to select the required style 4 9 2 2 Rotary Control The default condition for the rotary control is UNLOCKED i e active Set the DIAL field to LOCKED using the DIGIT keys to make the rotary control inactive 4 9 2 3 Power Up Setting With the cursor in the POWER UP field the setting can be changed from POWER UP DEFAULTS the default setting to POWER UP POWER DOWN i e settings at power down are restored at power up or POWER UP any of the settings stored in non volatile memories 1 to 9 POWER UP DEFAULTS restores the factory default settings see Appendix 2 4 9 2 4 Clock In Out Setting The function of the rear panel CLOCK IN OUT socket is determined by the setting in the CLOCK BNC field With CL
194. oggle the source between EXT VCA and TGEN Trigger Generator i e between external VCA mode and internal AM mode 4 5 1 1 Modulation Frequency Select TGEN in the SOURCE field and move the cursor to the TGEN field to set the period of the Internal Trigger Generator the modulation source for internal AM The internal trigger generator produces a squarewave with a period that can be set from 0 02ms 50kHz to 200s 005Hz Period entries that cannot be exactly set are accepted and rounded up to the nearest available value e g 109ms is rounded to 12ms The generator output is available as a TTL level signal at the rear panel TRIG SWEEP OUT socket Beside the generator period value the equivalent frequency is shown this is for information only and is not an editable field Because the internal trigger generator can be used by the trigger gate FSK and AM functions and can be set from their respective menus an information field is displayed in brackets beside TGEN when this is selected as the source This field will show FREE when TGEN is not used elsewhere or any of the letters G F A T to indicate the generator is currently set as the source on the GATE FSK AM or TRIG menus respectively in addition to the menu currently displayed GX1010 Il 27 4 6 28 Il 4 5 1 2 Modulation Depth Move the edit cursor to the INT MOD DEPTH field to set the modulation depth between 1 and 100 in 1 increments The maximum output 20Vpp
195. ol will select EXTERNAL then MANUAL alternatively they can be directly selected from the keyboard by entering 1ms and Oms respectively In EXTERNAL mode the sequence is stepped on at each rising edge of the trigger signal connected to the front panel EXT TRIG socket In MANUAL mode the sequence is stepped on with each press of the MAN SYNC key or appropriate remote command A synchronising signal is provided at the rear panel TRIG SWEEP OUT socket At the entry to each step the signal goes low followed by a rising edge after the frequency and waveshape have changed for the new step However the rising edge will generally occur before an amplitude or offset change if specified has been completed see Timing Considerations section 4 8 3 Running the Sequence To run the HOP sequence the edit cursor must be positioned in the HOP field alternate presses of the DIGIT keys will then toggle HOP between ON and OFF With HOP ON the edit cursor is suppressed and no editing is possible Exiting HOP by pressing ESCAPE automatically sets HOP OFF and returns the generator to the setting used before HOP was selected When HOP is running the HOP display will show the waveform parameters for each step which is manually stepped or has a duration gt 500ms the display will not track the changes of shorter steps or externally triggered steps 4 8 4 Timing Considerations The time to set up the waveform at each step will depend on the nature of the chang
196. ompagnant les signaux rampe escalier et arbitraire est par d faut toujours g n r ind pendamment l cart de phase est ajustable travers la gamme de fr quence mais de nouveau l instabilit d un cycle deviendra de plus en plus signifiant plus haute fr quence GX 1010 19 20 4 2 3 G n ration de signaux Un nombre de param tres est par d faut commut automatiquement soit quand la fr quence est au dessus de 30kHz ou quand le mode de fonctionnement est chang de telle fa on que la meilleure performance est donn e travers la gamme de fr quence du g n rateur voir la section op rations DDS pour plus de d tails sur le d passement 30kHz De plus les signaux triangle rampe escalier et arbitraire peuvent tre emp ch s d tre r gl s au dessus de 100kHz pour s assurer qu ils ne sont pas accidentellement utilis s des fr quences ou la forme est plus d t rior e Dans tous les cas le choix par d faut peut tre modifi par l utilisateur en changeant le r glage dans le menu options SQWAVE GEN AUTO FILTER AUTO AUX AUTO FSTOP ON SWEEP TGEN OUT AUTO Le menu options ci dessus est actif en pressant la touche bleue EDIT puis OPTN la fonction majuscule de 1 Les descriptions suivantes group es ensemble dans cette section par commodit doivent tre lues avec les explications principales du param tre appropri un autre endroit du manuel Chaque param tre est modifi en boug
197. onis s le maitre est r gl en sortie OUTPUT et le signal est utilis pour piloter l horloge CLOCK IN et les entr es esclaves PHASE LOCK Quand deux ou plus de g n rateurs sont synchronis s les esclaves sont r gl s sur PHASE LOCK Comme sortie les niveaux logiques sont 1V et 4V partir de 50Q CLOCK OUT r sistera a un court circuit Comme entr e le seuil est compatible TTL CMOS N appliquez pas de tension externe exc dant 7 5 V ou 2 5 V cette sortie 4 1 7 2 ENTREE VCA Modulation d amplitude C est la borne d entr e pour la modulation d amplitude externe contr l e par variation de tension VCA Limp dance d entr e est 6kQ Appliquez 2 5V pour une modulation 100 a la sortie maximale N appliquez pas de tension externe d passant 10V GX 1010 4 1 7 3 SORTIE SYNCHRO SYNC OUT Quand deux ou plus de g n rateurs sont synchronis s la borne SYNC OUT sur le g n rateur maitre est connect e aux entr es EXT TRIG des g n rateurs esclaves Les niveaux logiques SYNC OUT sont OV et 5V a partir de 509 SYNC OUT supportera un court circuit A N appliquez pas de tension externe cette sortie 4 1 7 4 SORTIE DECLENCHEMENT BALAYAGE TRIG SWEEP OUT La fonction de cette sortie est automatiquement d termin e par le mode de fonctionnement du g n rateur Except en mode Sweep et HOP la sortie est celle du g n rateur interne un signal carr d amplitude fix e dont la fr quen
198. onising Principles section Each generator can be set to any waveform The phase relationships between the slaves and the master are set individually on the Trigger menus of each slave exactly as described in the Triggered burst section The convention adopted in Synchronised mode is that a negative phase setting delays the slave output with respect to the master for example a phase setting of 90 will delay the slave by a quarter cycle with respect to the master If the slave s EXT TRIG inputs are all driven directly from the master then all phase shift is referenced from the master thus 4 generators set to the same frequency with the 3 slaves set to 90 180 and 270 respectively will give four evenly spaced phases of the same signal If however the synchronising signal was daisy chained from each SYNC to the next generator s EXT TRIG then the phase shifts become cumulative and each slave must be set to 90 phase to achieve the same result Hardware delays become increasingly significant as frequency increases causing additional phase delay between the master and slaves However these delays can be largely nulled out by backing off the phase settings of the slaves The phase setting on each slave affects the AUX OUT phase as described in the Auxiliary Output section Note though that the phase setting for synchronisation purposes is not subject to the same waveform dependent frequency limitations as AUX OUT The individu
199. onn lt freq gt est la fr quence du g n rateur principal en Hz lt niveau gt est le niveau de sortie exprim en EMF cr te cr te lt fonc gt est l un des suivants lt SINE gt lt SQUARE gt lt TRIAN gt lt POSPUL gt lt NEGPUL gt lt POSRAMP gt lt NEGRAMP gt lt STAIR gt ou lt ARB gt lt d calage gt est le d calage DC en Volts TRG Provoque un d clenchement qui aura le m me effet que d appuyer sur la touche MAN SYNC La source de d clenchement MAN REMOTE doit tre s lectionn e en premier La commande Group Execute Trigger GET remplira la m me fonction que TRG 5 2 10 Commandes de Syst mes BEEPMODE lt cpd gt R gle le mode bip sur lt ON gt lt OFF gt lt WARN gt ou lt ERROR gt BEEP Envoie un bip RCL lt nrf gt Rappelle l installation de l instrument contenu dans le num ro de m moire nrf Le num ro de m moire est valable de 0 a 9 Le rappel de la m moire O met tous les param tres aux r glages par d faut voir REGLAGE PAR DEFAUT DE LINSTRUMENT RST R initialise les param tres de l instrument leurs valeurs par d faut voir REGLAGE PAR DEFAUT DE L INSTRUMENT SAV lt nrf gt Sauvegarde l installation compl te de l instrument dans la m moire num ro nrf Num ro de m moire 50 GX 1010 5 2 11 Commandes d tat LRN LRN lt character data gt EER QER CLS ESE lt nrf gt ESE ESR IST OPC OPC PR
200. oppe la phase r gl e dans la zone PHASE 4 4 3 3 Phase de d part et d arr t La phase de d part et d arr t de salve d clench e est r gl e dans la zone PHASE La zone PHASE r gle en fait la phase de la sortie auxiliaire et c est de cette sortie que le contr le du point d part arr t du g n rateur principal est d riv le front montant du signal AUX OUT qui peut tre une phase diff rente de la sortie MAIN OUT d termine le d part et l arr t de salve du signal principal Par cons quent les conditions sous lesquelles l cart de phase est contraint et qui sont pleinement expliqu es dans cette section s appliquent la phase d part arr t Par exemple la phase d part arr t des signaux sinus et triangle ne peut tre ajust e pour des fr quences sortie principale de plus de 30kHz moins que la zone AUX OUTPUT du menu Options soit r gl e en mode g n ration LOW FREQ car AUX OUT ne continue d tre en cart phase que dans ce mode en respect avec MAIN OUT Du fait que le signal de contr le de phase est d riv du signal de sortie auxiliaire il y a d autres facteurs prendre en consid ration quand la fr quence du g n rateur principal augmente Avec AUX OUTPUT LOW FREQ dans le menu Options le contr le de d calage de phase est toujours disponible au dessus de 30kHz mais les retards d la technologie deviennent non n gligeables Le retard de la phase start stop augmente sans modification voulue de ch
201. orms Up to five arbitrary waveforms of 1024 10 bit words can be stored in non volatile memory The waveform clock is 27 48MHz maximum This facility considerably expands the versatility of the instrument making it suitable for the generation of highly complex waveform patterns In addition numerous complex waveforms are pre defined in ROM including commonly used waveshapes such as sinex x exponentially decaying sinewave etc Further waveshapes will be added to the library in response to customer requests Sweep All waveforms can be swept over their full frequency range at a rate variable between 10 milliseconds and 15 minutes The sweep is fully phase continuous Sweep can be linear or logarithmic single or continuous Single sweeps can be triggered from the front panel the trigger input or the digital interfaces Two sweep markers are provided AM Amplitude Modulation is available for all waveforms and is variable in 1 steps up to 100 An internal AM source is incorporated Alternatively modulation can be controlled from an external generator FSK Frequency Shift Keying provides phase coherent switching between two selected frequencies at a rate defined by the switching signal source The rate can be set from dc to 50kHz internally or dc to 1MHz externally GX1010 2 6 2 7 2 8 2 9 2 10 Trigger Burst amp Gated All waveforms are available as a triggered burst whereby each positive edge of th
202. ortes fusibles GX 1010 4 1 DESCRIPTION FONCTIONNELLE Cette section est une introduction g n rale aux caract ristiques et a l organisation des fonctions du g n rateur qui doit tre lue avant d utiliser l appareil pour la premi re fois Le fonctionnement d taill est d crit dans les sections suivantes d butant avec le fonctionnement du g n rateur principal G n ralit s 4 1 1 Principes Synth se Num rique Directe DDS Dans cet instrument les signaux sont g n r es par synth se num rique directe DDS Un cycle complet du signal est stock dans la RAM comme 1024 valeurs d amplitude 10 bits Quand l adresse RAM est incr ment e les donn es sur le signal vont vers un convertisseur num rique analogique DAC qui reconstitue le signal Les signaux sinuso daux et triangulaires sont ensuite filtr es pour lisser les sauts la sortie du DAC La fr quence du signal est d termin e par la vitesse laquelle les adresses RAM sont chang es De plus amples d tails sur la fa on dont cette vitesse change dont la fr quence change sont donn s plus tard dans la section fonctionnement DDS il suffit de savoir qu basse fr quence les adresses sortent s quentiellement mais haute fr quence les adresses sont chantillonn es Les avantages majeurs du syst me DDS sur le syst me analogique sont e La pr cision et la stabilit de fr quence sont celles d un oscillateur a cristal e Les fr quences peu
203. ortis en continu jusqu 27 kHz au del desquels ils sont chantillonn s 0 1mHz 7 digits Typique 10 ppm pour 1 an 18 C 28 C lt 1 ppm C Sinus triangle rampe 1 a 99 a toutes les fr quences Carr impulsion 1 a 99 a 30kHz 20 a 80 a 10MHz 0 1 Sinus carr impulsion positive et impulsion n gative signal carr multi niveaux triangle rampe ascendante rampe descendante courant continu ARB et bruit e Signal sinuso dale Niveau de sortie Distorsion harmonique Erreur non harmonique e Signal carr niveau de sortie Temps de mont e et descente e Triangle niveau de sortie Erreur de lin arit GX 1010 5mV 20V cr te cr te circuit ouvert o p lt 0 3 THD a 500kHz lt 50dBc 1MHz lt 35dBc a 10MHz Typique lt 55dBc 10MHz 5mV 20V cr te cr te circuit ouvert o p lt 25ns 5mV 20V crete cr te circuit ouvert o p lt 0 5 a 30 kHz 63 64 es Rampe Positive et N gative niveau de sortie 5mV a 20V cr te cr te circuit ouvert o p Erreur de lin arit lt 0 5 a 30 kHz e impulsion Positive et Negative niveau de sortie 2 5mV 10V cr te cr te circuit ouvert o p Temps de mont e et descente lt 25ns e Signal carr multi niveaux Jusqu 16 tapes disponibles par cycle chaque tape donnant choix pour l amplitude r solution 10 bits et la dur e 1 a 1024 chantillons Permet la g n ration sur 3 niveau
204. ot attenuated by the fixed attenuator and the actual DC offset in brackets is the same as that set FREQ 10 00000kHz EMF 2 50 Vpp 50Q DC 150 mV 150 mV SYM 50 0 50 0 If the output level is now reduced to 250mV pk pk which introduces the attenuator the actual DC offset changes by the appropriate factor FREQ 10 00000kHz EMF 250 mVpp 500 DC 150 mV 15 1mV SYM 50 0 50 0 The above display shows that the set DC offset is 150mV but the actual offset is 15 1mV Note that the actual offset value also takes into account the true attenuation provided by the fixed attenuator using the values determined during the calibration procedure In the example displayed the output signal is 250mV pk pk exactly and takes account of the small error in the 20dB fixed attenuator the offset is 15 1mV exactly taking account of the effect of the known attenuation slightly less than the nominal 20dB on the set offset of 150mV Whenever the set DC offset is modified by a change in output level in this way a warning message that this has happened will be displayed Similarly because the DC offset plus GX1010 signal peak is limited to 10V to avoid waveform clipping a warning message will be displayed This is explained more fully in the Warnings and Error Messages section 4 2 1 5 DC Output The DC Offset control can be used to provide an adjustable DC output level if the waveform is off the recommended set up is as fol
205. ou lt OFF gt Fixe la fr quence principale lt nrf gt Hz R gle le mode FSK mode sur lt ON gt ou lt OFF gt Fixe la fr quence du g n rateur principal lt nrf gt Hz Fixe la fr quence FSK B lt nrf gt Hz Fixe la p riode du g n rateur principal lt nrf gt secondes Fixe la p riode FSK B lt nrf gt secondes Fixe la source FSK sur lt EXT gt lt MAN gt ou lt TGEN gt Fixe le mode des portes sur lt ON gt ou lt OFF gt R gle la source des portes sur lt EXT gt lt MAN gt ou lt TGEN gt R gle l tat HOP sur lt RUN gt ou lt OFF gt la derni re tape tant fix e lt nrf gt Installe les donn es pour pr c dant R gle la fonction n gative d impulsion sur lt ON gt lt OFF gt lt WARN gt or une commande LRN 53 54 NEGRAMP NOISE lt cpd gt OUTPUT lt cpd gt PDPP lt nrf gt PDRMS lt nrf gt PER lt nrf gt PHASE lt nrfx gt PHASE lt nrf gt POSPUL POSRAMP SETARB lt nrf gt lt nrf gt SETHOP lt nrf gt lt nrf gt lt nrf gt lt nrf gt lt cpd gt lt nrf gt SETSTAIR lt nrf gt lt nrf gt SINE SQRWAVGEN lt cpd gt SQUARE STAIR SWEEP lt cpd gt SWPBEGFRQ lt nrf gt SWPBEGPER lt nrf gt SWPENDFRQ lt nrf gt SWPENDPER lt nrf gt SWPLAW lt cpd gt SWPMKRFRQ lt nrf gt SWPMKRPER lt nrf gt SWPMODE lt cpd gt SWPSRC lt cpd gt SWPTIME lt nrf gt SWPTRGOUT lt cpd gt SYMM lt nrf gt TGEN lt nrf g
206. our la modulation d amplitude interne Le g n rateur a d clenchement interne produit un signal carr avec une p riode qui peut aller de 0 02ms 50kHz a 200s 005Hz Les p riodes d entr e qui ne peuvent tre r gl es exactement sont accept es et arrondies a la plus proche valeur sup rieure la sortie g n rateur est disponible comme un signal niveau TTL la borne TRIG SWEEP du panneau arri re A c t de la valeur de p riode du g n rateur se trouve la fr quence quivalente uniquement pour information ne peut tre modifi e Du fait que le g n rateur d clenchement interne peut tre utilis par les fonctions trigger Porte GATE FSK et AM et peut tre r gl de leurs menus respectifs une zone d information est affich e entre parenth ses c t de TGEN quand ceci est choisi comme source Cette zone affichera FREE quand TGEN n est pas utilis autre part une des lettres G F A T pour indiquer que le g n rateur est d sormais r gl comme source sur le menu PORTE GATE FSK AM ou TRIG en plus du menu affich 4 5 1 2 Profondeur de Modulation D placez le curseur vers la zone INT MOD DEPTH pour r gler la profondeur de modulation de 1 100 en incr ments d 1 la sortie maximale 20Vpp EMF ne peut tre d pass e et une distorsion appara tra si la modulation tente de piloter la sortie par del ses limites Le r glage de sortie maximale du g n rateur jusqu auquel le fonctionnement correct
207. p end period to lt nrf gt seconds Set sweep marker frequency to lt nrf gt Hz Set sweep marker period to lt nrf gt seconds Set sweep mode to lt BTOE gt begin to end or lt ETOB gt end to begin Set sweep law to lt LOG gt or lt LIN gt Set sweep time to lt nrf gt seconds Set sweep source to lt CONT gt continuous lt EXT gt external or lt MAN gt manual Executes a trigger which will have the same effect as pressing the MAN SYNC key MAN REMOTE trigger source must be selected first GPIB Group Execute Trigger command GET will perform the same function as TRG Set trigger mode to lt ON gt or lt OFF gt Set gate mode to lt ON gt or lt OFF gt Set trigger source to lt EXT gt lt MAN gt or lt TGEN gt Set gate source to lt EXT gt lt MAN gt or lt TGEN gt Set trigger generator period to lt nrf gt seconds Set burst count to lt nrf gt cycles Set phase to lt nrf gt degrees Executes a trigger which will have the same effect as pressing the MAN SYNC key MAN REMOTE trigger source must be selected first GPIB Group Execute Trigger command GET will perform the same function as TRG Set AM mode to lt ON gt or lt OFF gt AM source to lt EXT gt or lt TGEN gt Set trigger generator period to lt nrf gt seconds Set internal AM depth to lt nrf gt Set internal AM wave to lt SINE gt or lt SQUARE gt Set FSK mode to lt ON gt or lt OFF gt Set main generator frequency to l
208. plus waveshape changes and gt 50ms for amplitude and offset changes If a shorter duration than that recommended above is set the results will be unpredictable and it is likely that HOP cannot be turned off in the usual way To recover from this situation hold the ESCAPE key down for 1s until HOP mode is exited 4 8 5 Saving HOP Settings The current HOP setting is saved in non volatile memory at power down It is not part of the data saved by the STORE function see Storing and Recalling Set ups section and therefore only one complete HOP sequence can be stored The HOP setting is not lost when the system defaults are reloaded System Operations 4 9 1 Storing and Recalling Set ups Complete waveform set ups can be stored to or recalled from non volatile RAM using the STORE and RECALL menus To store a set up press the STORE key in the Utilities section of the keyboard the display shows the following message SAVE TO STORE NO 1 CONFIRM TO EXECUTE Nine stores numbered 1 to 9 inclusive are available Select the store number using the rotary control or direct keyboard entry and press CONFIRM to execute the store function To recall a set up press the RECALL key the display shows the following RECALL STORE NO 0 O FOR DEFAULTS CONFIRM TO EXECUTE In addition to the user accessible stores numbered 1 to 9 store 0 contains the factory defaults which can be reloaded in the same way Note that loading the defaults d
209. ponibles en mode salve d clench par front montant du signal de d clenchement Chaque d clenchement produira une salve de la porteuse d marrant et s arr tant l angle de phase sp cifi par le r glage de phase start stop Le nombre de cycles de salves peut tre r gl entre 0 5 et 1023 Le mode porte allume le signal de sortie quand le signal d clencheur de porte est haut et l teint quand il est bas Les deux modes ci dessus fonctionnent a partir du g n rateur d clencheur interne 0 005Hz a 50 kHz ou d une source externe du continu a 1 MHz Saut de signal et bruit Le g n rateur peut tre r gl pour sauter hop automatiquement d un r glage a l autre soit une vitesse pr d termin e soit en r ponse un d clenchement manuel Jusqu 16 sauts de signaux diff rents peuvent tre d finies en terme de fr quence amplitude fonction d calage et dur e qui est variable par pas de 1ms jusqu 60 s Le g n rateur peut aussi tre r gl pour simuler un bruit al atoire dans une largeur de bande de 0 03Hz 700 kHz avec amplitude et d calage ajustables G n rateurs v rouillage de phase multiple Les signaux provenant de la prise entr e sortie horloge et de la prise sortie synchro peuvent tre utilis s pour bloquer la phase de deux ou plusieurs g n rateurs Ceci peut tre utilis pour g n rer des signaux multi phases ou des signaux v rouill s sur diff rentes fr quence
210. que Il faut noter qu il n y a pas de param tres d pendants de param tres coupl s de commandes de chevauchement d l ments de donn es de programme d expression ni d en t tes de programmes de commande compos s et que chaque commande est enti rement ex cut e avant le d but de la commande suivante Toutes les commandes sont s quentielles et le message signalant que l op ration est termin e est dans tous les cas g n r imm diatement apr s l x cution Les sections de commandes suivantes utilisent la nomenclature suivante lt pmt gt lt PROGRAM MESSAGE TERMINATOR gt lt rmt gt lt RESPONSE MESSAGE TERMINATOR gt lt cpd gt lt CHARACTER PROGRAM DATA gt c est dire un petit mn monic ou une chaine de caract res ON et OFF par exemple lt nrf gt Nombre en tout format par exemple 12 12 00 1 2e1 et 120e 1 sont tous accept s en tant que nombre 12 Tout nombre recu est converti a la pr cision requise correspondant l utilisation puis arrondi pour obtenir la valeur de la commande lt nr1 gt Nombre sans partie fractionnaire c a d nombre entier lt nr2 gt Nombre sous format a virgule fixe par exemple 11 52 0 78 etc eal Tous les l ments entre ces crochets sont des param tres facultatifs S il y a plus d un l ment tous les l ments ou aucun l ment ne sont n est requis Les commandes commen ant par a sont celles sp cifi es par IEEE Std 488 2 comme des commandes Habituelle
211. queurs Pour les balayages d clench en externe un signal d clencheur doit tre fourni la borne avant EXT TRIG Un balayage est initialis par le front montant du signal d clencheur Le g n rateur ne fournit pas de sortie rampe pour utilisation avec les affichages X Y ou les enregistreurs 4 3 3 R glage de la port e de balayage et marqueurs Presser la touche bleue EDIT puis SWEEP affiche la premi re page des param tres balayage avec des valeurs aux r glages usine BEG FRO 100 0000kHz END FRO 10 00000MHz MARK FRO 5 000000MHz MORE gt gt gt Les fr quences d but BEG fin END et MARKER peuvent toutes tre r gl es ou modifi es de la m me fa on que pour la fr quence du g n rateur principal En r sum GX 1010 avec le curseur dans la premi re zone de n importe quelle ligne les touches DIGIT ou la molette alterneront l affichage entre FRQ et PER avec le curseur dans la zone num rique les touches DIGIT d placeront le curseur dans la zone num rique les touches DIGIT d placeront le curseur dans la zone et la molette changera la valeur par incr ments d termin s par la position du curseur avec le curseur dans les zones unit s les touches DIGIT ou la molette incr menteront par dizaine L entr e directe par clavier nombre et unit sera accept e avec le curseur n importe o sur la ligne d affichage Notez que si le mode balayage est r ellement activ s lectionn par pressions
212. r gl e a 90 mais la sym trie r elle est 80 la limite pour les signaux carr s et impulsions n exc de pas de 30kHz Le curseur clignotant peut tre boug dans la zone par les touches DIGIT tourner la molette incr mentera ou d cr mentera le r glage au pas d termin par la position du curseur dans la zone Si la sym trie est hors de la gamme permise par la combinaison signal fr quence un message d alerte apparaitra voir section messages d alerte et d erreur 4 2 1 7 Messages d alerte et d erreur Deux classes de messages apparaissent l cran quand une mauvaise combinaison de param tres survient Les messages WARNING apparaissent quand le r glage entr cause un changement que Putilisateur n attend pas Les exemples sont 1 Changer l EMF de 2 5Volts cr te cr te a 250mV cr te cr te active l att nuateur si un offset diff rent de z ro a t r gl alors il sera att nu aussi le message DC OFFSET CHANGE BY OUTPUT LEVEL s affichera mais le r glage sera accept dans ce cas l offset r el att nu sera entre parenth ses a droite de la valeur r glage 2 Avec le niveau sortie r gl a 10V cr te cr te augmenter lPoffset DC au dela de 5V lancera le message DC OFFSET LEVEL MAY CAUSE CLIPPING Le changement d offset sera accept produisant un signal cr t et Putilisateur pourra changer le niveau de sortie ou l offset pour produire un signal sans cretage 3 A
213. r quence jusqu ce que MAN SYNC soit press e de nouveau pour permettre au balayage de continuer 4 3 5 R solution de pas en fr quence Le g n rateur de fr quence est chantillonn et non vraiment balay entre les fr quences de d but BEG et de fin END Le nombre de pas fr quence dans un balayage est d termin par le temps de rampe choisi dans le menu balayage la taille de chaque pas ex la r solution de pas fr quence est d termin e par le nombre de pas et l envergure de balayage Pour les balayages les plus rapides 10ms 200ms les pas fr quence sont pr calcul s et sortis par intervalles de 125 us ceci signifie qu il y a 80 pas discrets dans un balayage de 10ms 160 dans un balayage de 20ms et ainsi de suite jusqu 1600 pas pour un balayage de 200ms Pour les balayages lents de gt 200ms a 999s chaque pas fr quence est calcul au vol et sorti toutes les 5ms ceci signifie qu il y a 100 pas pour 500ms 200 pour 1s et ainsi jusqu 200 000 pas dans un balayage de 999s Notez qu aux vitesses de balayages les plus rapides avec les pas les plus courts balayage 10 ms deux effets peuvent se produire aux extr mes de la gamme de fr quence Ces effets ne sont pas habituels avec des g n rateurs conventionnels Premi rement si le balayage est tr s large les changements de fr quence seront assez longs si la sortie est branch e un filtre par exemple la r ponse sera une succession de changeme
214. r la file d attente de sortie L analyseur syntaxique commence alors l analyse syntaxique du lt PROGRAM MESSAGE UNIT gt suivant de la file d attente d entr e Voir la section REGISTRE D ETAT pour plus d informations cet effet L erreur DEADLOCK IEEE 488 2 est g r e de la mani re suivante Si la mise en forme de r ponse attend de transmettre un message de r ponse et que la file d attente d entr e est pleine l instrument passe alors l tat DEADLOCK et une erreur se produit Ceci entra ne le r glage du bit Query Error dans le Standard Event Status Register 2 est plac dans le Query Error Register et la mise en forme de r ponse est r initialis e ce qui d gage la file d attente de sortie L analyseur syntaxique commence analyser la syntaxe du lt PROGRAM MESSAGE TERMINATOR gt suivant de la file d attente d entr e Voir la section REGISTRE D ETAT pour plus d informations cet effet GX 1010 5 1 3 3 Appel GPIB parall le Cet appareil de mesure universel offre des capacit s d appel compl tes en parall le Le Parallel Poll Enable Register est r gl pour sp cifier les bits du Status Byte Register utilis s pour constituer le message local ist Le Parallel Poll Enable Register est r gl par la commande PRE lt nrf gt et lu par la commande PRE La valeur du Parallel Poll Enable Register est ANDed avec le Status Byte Register si le r sultat est z ro la valeur de ist est 0 et sinon la valeur de ist est 1 Il fau
215. r la limite pratique soit fix e 10MHz 6 5 2 Autres Consid rations de signal Les diff rentes limites des combinaisons de modes dont la plupart ont d j t vues dans les sections concern es du manuel sont r unies ici et d taill es en faisant r f rence au diagramme ci dessous 60 GX 1010 6 5 2 1 Diagramme simplifi du bloc de g n rateur Rampe Stair Arbitoire LF carr et yi Comparateur pour carr impulsions et toutes formes sym triques C HF et impulsions Sortie principale Sinus Triangle Sinus pour HF carr e et impulsions Sortie MAN REMOTE O auxiliaire DECLENCHEMENT O EXTERNE Contr le 3 Contr le 2 Le diagramme montre les parties simplifi es pour les sorties principales ou auxiliaires LF et HF correspondent aux modes Low Frequency Fr quence basse et High Frequency Fr quence haute r gl s pour une sortie signal carr Impulsion et Auxiliaire dans les champs du menu Options SQWAVE GEN et AUX voir la section g n rateurs de signaux Quand ces champs sont fix s sur AUTO les modes changent automatiquement de LF HF au dessus de 30kHz se r gler sur LF ou HF fixera ce mode de g n ration quelle que soit la fr quence du g n rateur De fa on similaire quand le filtre est r gl sur AUTO dans le menu Options il sera mis sur entr e ou sortie selon la forme des signaux se r gler sur Filtre ON ou OFF annulera ceci et soit toutes soit aucune de
216. r la touche bleue EDIT suivie d une touche MODE affiche le menu pour cette fonction la DEL associ e clignote pendant l affichage menu e Les touches UTILITIES donnent acc s aux menus param tre Interface STORE et RECALL la touche MAN SYNC est utilis e pour un d clenchement manuel et la synchronisation de deux ou plusieurs g n rateurs connect s ensemble e Enfin les touche CONFIRM ESCAPE et CE clear Entry s expliquent d elles m mes Les entr es num riques sont automatiquement confirm es quand la touche unit Hz kHz Mhz etc est press e mais CONFIRM peut tre utilis e pour entrer un nombre dans les unit s basiques de param tres ou pour confirmer des entr es avec des unit s fix es phase ou sans unit compteur de salves Elle est aussi utilis e pour confirmer des options Appuyer sur ESCAPE ram ne un r glage sa derni re valeur une seconde pression ram nera au menu principal CE Clear Entry efface une entr e chiffre par chiffre De plus amples explications seront trouv es dans les descriptions d taill es des fonctions du g n rateur GX 1010 4 1 5 Principes d dition Les touches FIELD et DIGIT sont utilis es toutes deux avec le commutateur rotatif pour diter les param tres affich s dans le menu courant Le menu montre tous les param tres basiques du g n rateur il est affich a moins qu une fonction sp ciale soit dit e Ces menus d dition sont accessibles en press
217. r principal 48 5 2 3 Param tres de balayage is 48 5 2 4 D clenchements et Portes sra dle colillas 48 5 2 5 Param tres AM Modulation d amplitude 49 LA AN O e e ad e 49 5 2 7 Formes de signaux escaliers et arbitraires 49 5 2 8 Options sur les G n rations de Formes de signaux 50 5 2 9 Commandes HOP nine Ar 50 5 2 10 Commandes de SOME Eed geg Mere EEN testi exeensedlenetebteeenimeenolees 50 52 11 Commandes d tat ii 51 5 2 12 Commandes diverses a3 une LU D dd Rd NE 52 5 2 13 Commande de v rouillage de phase 52 5 3 R sum de commandes e TE ne 52 6 APPLICATIONS cuca en aaa aa a te tte 55 6 1 R glages par d faut rna n a E EE AER EAE ERE ER A a 55 6 2 Op ration Simple du G n rateur Principal 55 6 37 Trans A IMPUISION een ee a e eege eet eet aE e ea AE E 55 6 3 1 Trains d impulsions faible rapport cyclique 56 6 3 2 IMPUISIONS Multiple S 0 di 57 6 4 Impulsion transition variable ss 57 6 4 1 Transitions vitesse limit e 57 6 4 2 Impulsions Bande limit e acorta ete en deren dads ieee ne Mes re 58 6 4 3 Impulsions avec OVBrShN0O ananas fede nati an tan n 58 6 5 Op rations DDS et autres Consid rations de formes de signaux 59 6 5 1 Op rations DDS viii ir 59 6 5 2 Autres Considerations de signal EE 60 7 SPECIFICATIONS TECHNIQUES caian ada 63 7 1 G n ralit s eaan a a 63 A E 63 GX 1010 7 2 1 Performances fonctionnelles iiiiecereceeeceeeceeeneeeneeeetee 63 7 2 2 DO
218. r the generator frequency Control 2 Similarly when set to AUTO on the Options menu the Filter will be switched in or out depending on waveform as shown setting Filter ON or OFF will override this and all or none of the waveforms will be filtered 6 5 2 2 Interaction of Various Option Settings The more important points to consider when setting the Option menu fields to other than AUTO are as follows e The comparator which generates MAIN HF squarewaves pulses is driven by default by a filtered sinewave If the filter is set OFF the waveform driving the comparator will be poorer and the HF squarewave etc will be degraded e HF AUX out is generated from the same comparator the waveform driving the comparator depends on the MAIN waveform selection For HF squarewave pulse MAIN outputs the driving waveform is a filtered sinewave as described above for sinewave and triangle main outputs the comparator drive is the waveform itself also filtered The main waveform also drives the comparator for ramp staircase and arbitrary waveforms plus LF squarewave pulses all of which are unfiltered this means that if the MAIN waveform shows edge jitter as the frequency increases so will the HF AUX out For this reason the default AUTO setting for AUX out is LF mode at all frequencies for main waveforms of ramp staircase arbitrary and LF squarewaves pulses e By default ramp staircase arbitrary and all waveforms whose symmetry is set to
219. rameters can be incremented or decremented using the rotary encoder This system combines quick and easy numeric data entry with quasi analogue adjustment when required Addressable RS 232 standard GPIB The generator has an RS 232 interface as standard which can be used for remote control of all of the instrument functions or for the down loading of arbitrary waveforms As well as operating as a conventional RS 232 interface it can also be used in addressable mode whereby up to 32 instruments can be linked to one PC serial port A GIPB interface conforming to IEEE 488 2 is available GX1010 Il 5 3 3 6 Il COMMISSIONING Assembly When a three core mains lead with bare ends is provided it should be connected as follows Brown Mains Live Blue Mains Neutral Green Yellow Mains Earth WARNING THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous Intentional interruption is prohibited The protective action must not be negated by the use of an extension cord without a protective conductor Power supply 3 2 1 Main power supply Check that the instrument operating voltage marked on the rear panel is suitable for the local supply Warning ANY ACTION TO MODIFY THE OPERATING VOLTAGE MUST BE DONE BY A QUALIFIED PERSON FOR SERVICING AND NOT BY THE USER Should it be necessary to change the operating voltage proceed as follows
220. rbitrary waveform from store lt nrf gt Query the selected arbitrary waveform responds SETARB lt 1024 nr1 gt lt rmt gt 5 2 8 Waveform Generation Options SQRWAVGEN lt cpd gt FILTER lt cpd gt AUX lt cpd gt SWPTRGOUT lt cpd gt 5 2 9 HOP HOP lt cpd gt lt nrf gt SETHOP lt nrf gt lt nrf gt lt nrf gt lt nrf gt lt cpd gt lt nrf gt TRG 5 2 10 System Commands BEEPMODE lt cpd gt BEEP 48 II Set squarewave generation mode to lt AUTO gt lt HF gt or lt LF gt Set filter mode to lt AUTO gt lt ON gt or lt OFF gt Set AUX output mode to lt AUTO gt lt HF gt or lt LF gt Set sweep tgen output bnc mode to lt AUTO gt lt SWEEP gt or lt TGEN gt Set HOP status to lt RUN gt or lt OFF gt with last step set to lt nrf gt Data for one step in the sequence lt step gt lt time gt lt freq gt lt level gt lt func gt lt offset gt lt step gt is the step number to be defined lt time gt is the time in seconds to remain in this step If set to O MANUAL will be selected If set to le 3 EXTERNAL will be selected lt freq gt is the main generator frequency in Hz lt level gt is the output level expressed in EMF Vpp lt func gt isany of lt SINE gt lt SQUARE gt lt TRIAN gt lt POSPUL gt lt NEGPUL gt lt POSRAMP gt lt NEGRAMP gt lt STAIR gt or lt ARB gt lt offset gt is the DC Offset in Volts Executes a trigger which will have the same effect as pressing
221. rder Additionally the output provides narrow 1V pulses at each marker frequency see Setting Sweep Span and Markers section For externally triggered sweeps a trigger signal must be provided at the front panel EXT TRIG socket A sweep is initiated by the rising edge of the trigger signal The generator does not provide a ramp output for use with X Y displays or recorders 4 3 3 Setting Sweep Span and Markers Pressing the blue EDIT key followed by the SWEEP key displays the first page of the sweep parameters with values set to factory defaults BEG FRQO 100 0000kHz END FRQ 10 00000MHz MARK FRO 5 000000MHz MORE gt gt gt The BEGin END and MARKER frequencies can all be set or modified in exactly the same way as described for the setting of the frequency in the Main Generator section In summary with the cursor in the first field of any line the DIGIT keys or rotary control will alternate the display between FRQ and PER with the cursor in the numeric field the DIGIT keys will move the cursor within the field and the rotary control will change the value in increments determined by the cursor position with the cursor in the units field the DIGIT keys or rotary control will change the value in decade increments Direct keyboard entries number plus units will be accepted with the cursor anywhere in the line of the display Note that if sweep mode is actually on selected by alternate presses of the SWEEP key and the ramp time is
222. rm Considerations ocooocccccnncooocccccnncccnnnnnannncnnnnnnnnnnnnnnnnnccnnnnnnnnnnnnnnnnno 57 T SPECIFICATIONS Sn A de ace 60 EN BE EE 60 ERR le Ee e Le 60 7 2 1 Functional PEMOrMANCS entrent ie a nee a aA 60 PL AIN RE saath en ee eebe aere ee eege 64 7 2 3 General Bio Weu 64 13 ENVIO MA nt al tio os 64 A O oes 64 A E CPR EE a e E E E aE 64 FA Ee e A A E EE Le 65 VD PICCOS SONOS sce ec chores ete E nee EC tele Eet AE 65 KEN RI 65 ANNEXE 1 Warning and Error Messages ns 66 ANNEXE 2 Factory System Defaults is ssssnnnnrsrresnnnnnnnnnenennnnnnnnes 68 GX1010 1 1 GENERAL INSTRUCTIONS This function generator is a Safety Class instrument according to IEC classification and has been designed to meet the requirements of IEC1010 1 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use It is an Installation Category II instrument intended for operation from a normal single phase supply Precautions and safety measures 1 1 1 Preliminary This instrument has been tested in accordance with IEC1010 1 and has been supplied in a safe condition This instruction manual contains some information and warnings which have to be followed by the user to ensure safe operation and to retain the instrument in a safe condition This instrument has been designed for indoor use in a Pollution Degree 1 environment no pollution or only dry non conductive pollution in the temperature range 5 C to 40
223. rument has a response message formatted and ready to send to the controller The bit will be cleared after the Response Message Terminator has been sent Bit 3 Not used Bit 2 Not used Bit 1 Not used Bit O Not used GX1010 Il 43 44 Il POWER ON COMMAND ERROR REGISTER EER READ AND CLEAR REGISTER QER READ AND CLEAR OPERATION COMPLETE Vv Vv Vv 7 X 5 4 X e X 900000 STANDARD EVENT STATUS 7 Se E x E ENABLE REGISTER ESE lt NRF gt SET TO lt NRF gt CH ESR READ AND CLEAR ESE READ RESPONSE READY SRO ROS STATUS BYTE REGISTER CEN x lesa may x x x x SERIAL POLL READ WITH ROS STB READ WITH MSS SERVICE REQUEST ENABLE REGISTER SRE lt NRF gt SET TO lt NRF gt SRE READ Status Model 5 1 6 ARC Remote Command Formats Serial input to the instrument is buffered in a 256 byte input queue which is filled under interrupt in a manner transparent to all other instrument operations The instrument will send XOFF when approximately 200 characters are in the queue XON will be sent when approximately 100 free spaces become available in the queue after XOFF was sent This queue contains raw un parsed data which is taken by the parser as required Commands and queries are executed in order and the parser will not start a new command until any previous command or query is complete There is no output queue w
224. s Utilisation simple Tous les param tres du g n rateur principal sont clairement affich s sur un cran de 4 lignes de 20 caract res Des sous menus sont utilis s pour les modes modulation et autres fonctions complexes Tous les param tres peuvent tre entr s directement avec le clavier num rique De plus beaucoup de param tres peuvent tre incr ment s ou d cr ment s en utilisant encodeur rotatif Ce syst me combine une entr e des donn es num riques rapide avec un ajustement quasi analogique si n cessaire Standard RS 232 adressable GPIB Ce g n rateur poss de une interface RS 232 en standard qui peut tre utilis e pour t l commander toutes les fonctions de l instrument ou le chargement de signaux arbitraires Fonctionnant comme une RS 232 conventionnelle elle peut aussi tre utilis e en mode adressable par lequel jusqu 32 instruments peuvent tre connect s un port s rie PC De plus une interface GPIB conforme la norme IEEE 488 2 est disponible GX 1010 TS 3 3 PREPARATION A L UTILISATION Assemblage Quand un cordon secteur 3 fils est fourni sans prise les fils doivent tre connect s comme suit Brun PHASE Bleu NEUTRE secteur Vert jaune TERRE ATTENTION CET INSTRUMENT DOIT ETRE RACCORDE A LA TERRE Toute interruption de la masse l int rieur ou l ext rieur de l instrument rendra ce dernier dangereux Toute interruption volontaire est a proscrire L utilisatio
225. s tre desactiv de la fa on habituelle Afin de se sortir de cette situation appuyez sur la touche ESCAPE pendant a peu pr s 1s jusqu ce que le mode HOP soit d sactiv GX 1010 4 9 4 8 5 Sauvegarder les R glages HOP Les r glages HOP du moment sont sauvegard s dans la m moire permanente quand l appareil est teint Ils ne font pas partie des donn es sauvegard es par la fonction STORE voir la section stockage des r glages et rappel et ainsi une seule s quence enti re HOP peut tre enregistr e Les r glages HOP ne sont pas perdus quand les param tres par d faut du syst me sont recharg s Modes d op rations 4 9 1 Stockage des r glages et Rappels Tous les r glages des signaux peuvent tre stock s ou rappel s de la RAM non volatile grace aux menus STORE et RECALL Pour stocker un r glage appuyez sur la touche STORE situ e dans la section UTILITIES du clavier on peut alors visualiser le message suivant SAVE TO STORE NO 1 CONFIRM TO EXECUTE Neuf num ros de stockage num rot s de 1 9 sont disponibles S lectionnez le num ro de stockage avec le commutateur ou en utilisant directement le clavier puis appuyez sur CONFIRM pour sauvegarder la fonction Pour rappeler un r glage appuyez sur la touche RECALL Vous pourrez alors visualiser le message suivant RECALL STORE NO 0 O FOR DEFAULTS CONFIRM TO EXECUTE En plus des neuf num ros de stockage num rot s de 1 a 9 l
226. s Elle fonctionneront toutes si elles sont utilis es avec l interface ARC mais certaines ne sont pas tr s utiles 5 2 1 S lection de la fonction SINE Fixe la fonction sinus SQUARE Fixe la fonction carr e TRIAN Fixe la fonction triangulaire GX 1010 47 POSPUL NEGPUL POSRAMP NEGRAMP STAIR ARB NOISE lt cpd gt Fixe la fonction impulsion positive Fixe la fonction impulsion n gative Fixe la fonction rampe positive Fixe la fonction rampe n gative Fixe la fonction escalier Fixe la fonction arbitraire Fixe le bruit NOISE sur lt ON gt ou lt OFF gt 5 2 2 Param tres du g n rateur principal OUTPUT lt cpd gt FREQ lt nrf gt PER lt nrf gt EMFPP lt nrf gt EMFRMS lt nrf gt PDPP lt nrf gt PDRMS lt nrf gt DBM lt nrf gt ZOUT lt nrf gt DCOFFS lt nrf gt SYMM lt nrf gt PHASE lt nrf gt Fixe la sortie sur lt ON gt lt OFF gt lt NORMAL gt ou lt INVERT gt Fixe la fr quence principale a lt nrf gt Hz Fixe la p riode principale a lt nrf gt secondes Fixe le niveau de sortie a lt nrf gt emf Vpp Fixe le niveau de sortie a lt nrf gt emf Vrms Fixe le niveau de sortie a lt nrf gt pd Vpp Fixe le niveau de sortie a lt nrf gt pd Vrms Fixe le niveau de sortie a lt nrf gt pd dBm Fixe l imp dance de sortie a lt nrf gt seuls 50 or 600 sont permis Fixe le d calage DC a lt nrf gt Volts Fixe la sym trie a lt nrf gt Fixe la phase a lt nrf gt degr s
227. s some addresses to be skipped giving the effect of the stored waveform being sampled different points will be sampled on successive cycles of the waveform The minimum number of points required to accurately reproduce a waveshape will determine the maximum useful output frequency fmax fCLK No of points For sinewaves the filter permits the waveform to be reproduced accurately up to the Nyquist limit fcLk 2 although in this generator a practical limit of 10MHZz is set 6 5 2 Further Waveform Considerations The various limitations on combinations of modes mostly already mentioned in the appropriate operational sections of the manual are brought together here and explained with reference to the simplified block diagram below GX1010 Il 57 58 Il 6 5 2 1 Simplified Generator Block Diagram Ramp Stair Arb LF Square and Pulse and all asymmetric waves Ve Comparator for HF Square and Pulse Q O MAIN O O Sine Triangle Sine for HF Square and Pulse MAN REMOTE EXTTRIG O Control 3 The diagram shows the simplified paths for the main and auxiliary outputs LF and HF refer to the Low Frequency and High Frequency modes set for Squarewave pulses and Auxiliary output in the SQWAVE GEN and AUX fields of the Options menu see Waveform Generation Options section When these fields are set to AUTO the modes automatically change from LF to HF above 30kHz setting to LF or HF will set that generating mode whateve
228. s transitoires d apparaitre sur la sortie Le signal de synchronisation sur la prise du panneau arri re TRIG SWEEP OUT est une impulsion lente dont les fronts descendants ont lieu au d but de chaque s quence peu pres ims apr s le d clenchement externe Le front montant a lieu apr s la fin d un changement de fr quence de signal respectivement 0 5ms ou 3ms apr s Dans le cas d un changement d amplitude ou de d calage le front montant a lieu un peu plus tard mais largement avant le d lai de 40ms n cessaire pour garantir que le changement ait t termin mais si le changement d amplitude n cessite la commutation de l att nuateur le front montant aura lieu apr s que l att nuateur ait chang et que la sortie ait t r activ e La dur e des r glages de l chelon est minut e partir du front montant du signal de synchronisation a la borne TRIG SWEEP OUT La dur e minimum de l chelon de 2ms peut tre utilis e seulement pour les changements de fr quence mais le temps n cessaire pour valider les changements forme de signal amplitude d calage d termine un minimum pratique qui est plus grand Les temps recommand s sont sup rieurs a 10ms pour les changements de fr quence et les formes de signaux gt 50 ms et pour les changements d amplitude et de d calage Si une dur e plus petite que celle recommand e plus haut est r gl e les r sultats obtenus ne sont pas pr visibles et il est possible que le HOP ne puisse pa
229. s with IEEE Std 488 1 1987 and IEEE Std 488 2 1987 5 1 3 1 GPIB Subsets This instrument contains the following IEEE 488 1 subsets Source Handshake SH1 Acceptor Handshake AH Talker T6 Listener L4 Service Request SR1 Remote Local RL1 Parallel Poll PP1 Device Clear DC1 Device Trigger DT1 Controller CO Electrical Interface E2 GX1010 5 1 3 2 GPIB IEEE Std 488 2 Error Handling The IEEE 488 2 UNTERMINATED error addressed to talk with nothing to say is handled as follows If the instrument is addressed to talk and the response formatter is inactive and the input queue is empty then the UNTERMINATED error is generated This will cause the Query Error bit to be set in the Standard Event Status Register a value of 3 to be placed in the Query Error Register and the parser to be reset See the STATUS REPORTING CAPABILITIES section for further information The IEEE 488 2 INTERRUPTED error is handled as follows If the response formatter is waiting to send a response message and a lt PROGRAM MESSAGE TERMINATOR gt has been read by the parser or the input queue contains more than one END message then the instrument has been INTERRUPTED and an error is generated This will cause the Query Error bit to be set in the Standard Event Status Register a value of 1 to be placed in the Query Error Register and the response formatter to be reset thus clearing the output queue The parser will then start parsing the next lt PROGRAM MESSAGE UNIT g
230. s all the basic generator parameters and is the one displayed unless editing of a special function has been selected These edit menus are accessed by pressing the blue EDIT key followed by the appropriate MODE key or a numeric key which has a secondary function printed in blue FIELD keys move the flashing edit cursor forward or backwards from one editable field to the next all the digits of a numeric parameter value are treated as a single field When the parameters of a particular function occupy two or more pages of the display e g the sweep mode parameters the further pages are indicated by MORE gt gt gt shown in the display and the FIELD keys are also used to step between the end of one page and the start of another and vice versa The attributes of the flashing edit cursor can be changed by the user if desired see SYStem Menu section DIGIT keys operate in more than one mode When a numeric parameter value field is selected by the FIELD keys DIGIT keys step the edit cursor forward or backwards through the digits of the field When the edit cursor is positioned in a parameter name e g FREQ pressing either digit key will step the parameter through each of the alternative forms in which a value may be entered e g FREQ is changed to PERiod the parameter numeric value and units change accordingly Note that where there is no alternative form for the parameter e g SYMMETRY the edit cursor cannot be stepped into that field When the
231. s d alerte 00 Aucune erreur ou alerte n a t rapport e 07 Changement du d calage par le niveau de sortie 09 Sym trie trop large pour la fonction fr quence 10 Changement de la sym trie par la fonction fr quence 11 Att nuation du d calage DC par le niveau de sortie 14 G n rateur de d clenchement max res 20us 17 Changement de l angle de phase par la fonction fr quence 20 Cet instrument n a pas t calibr 22 Operation ill gale ici Cette alerte est utilis e dans le cas o certaines touches sont enclench es pendant des op rations alors qu elles sont ill gales Ces op rations sont L instrument est un esclave synchrone Les modes Edit de STAIR et ARB Mode HOP s lectionn Bruit s lectionn Des explications compl tes concernant les restrictions pourront tre trouv es dans les sections correspondantes du manuel 23 Mode ill gal dans le cas d un esclave synchrone 24 Temps de salve exc de la p riode TGEN 25 D calage DC le niveau peut causer une distorsion e Messages d erreurs 101 Valeur Fr quence P riode hors limite 102 Niveau de sortie max d pass 103 Niveau de sortie min d pass 104 Unit s demand es ill gales 105 D calage DC min d pass 106 D calage DC max d pass 108 Valeur de sym trie ill gale 112 P riode du g n rateur de d clenchement trop grande 113 P riode du g n rateur de d clenchement trop petite 115 Valeur de d compte de salve hors limite 116 Va
232. s formes des signaux seront filtr es 6 5 2 2 Interaction des diff rents r glages optionnels Les points les plus importants consid rer pour les champs du menu Option sont les suivants e Le comparateur qui g n re les signaux carr s et impulsions MAIN HF est command par d faut par un signal sinusoidal filtr Si le filtre est sur OFF le signal commandant le comparateur sera plus pauvre et le signal carr e HF etc seront d t rior es e La sortie HF AUX est g n r e par le m me comparateur la forme du signal pilotant le comparateur d pend de la s lection de la forme du signal MAIN principale Pour les sorties signaux carr s impulsion HF la forme du signal entra nant est un signal sinuso dale filtr e comme d crit ci dessus pour les sorties principales de signal sinuso dale et triangulaire le comparateur en commande est la forme du signal elle m me filtr e elle aussi La forme du signal principal commande aussi le comparateur pour des formes de signaux arbitraires escalier rampe ainsi que les signaux carr s impulsions LF qui sont tous non filtr es Ceci veut dire que si les fronts de la forme du signal principale se mettent osciller au fur et mesure que la fr quence augmente alors la sortie HF AUX aussi C est pourquoi le r glage par d faut AUTO pour la sortie AUX est le mode LF pour toutes les fr quences des formes des signaux principaux rampes escalier arbitraires et signaux carr es impuls
233. si le message local est faux ou 1 lt rmt gt si le message local est bon R gle le bit Operation termin e bit 0 dans le Standard Event Status Register Ceci se produit imm diatement apr s l execution de la commande par suite de la nature s quentielle de toutes les op rations Interrogation d tat op ration termin e Syntaxe de la r ponse 1 lt rmt gt La r ponse est disponible imm diatement apr s l ex cution de la commande par suite de la nature s quentielle de toutes les op rations R gle le Parallel Poll Enable Register la valeur lt nrf gt Renvoie la valeur du Parallel Poll Enable Register sous le format num rique lt nri gt Syntaxe de la r ponse lt nri gt lt rmt gt R gle le Service Request Enable Register lt nrf gt Si la valeur de lt nrf gt Renvoie la valeur du Service Request Enable Register sous format num rique lt nr1 gt Syntaxe de la r ponse lt nr1 gt lt rmt gt Renvoie la valeur du Status Byte Register sous format num rique lt nr1 gt Syntaxe de la r ponse lt nr1 gt lt rmt gt Attendre la fin de operation Comme toutes les commandes sont enti rement ex cut es avant que la 51 suivante commence cette commande ne joue pas de r le suppl mentaire 5 2 12 Commandes diverses IDN renvoie l identification de l instrument La r ponse exacte est d termin e par la configuration de l instrument et elle a la forme suivante lt NAME gt lt model gt
234. sor in the numeric field turning the rotary control will increment or decrement the numeric value in steps determined by the edit cursor position within the field The DC OFFSET or FIELD keys move the cursor to the field and the DIGIT keys move it within the field this is more fully explained in the Principles of Editing section Because DC offset can have negative values the rotary control can take the value below zero although the display may autorange to a higher resolution if a step takes the value close to zero the increment size is maintained correctly as the offset is stepped negative For example if the display shows DC 205 mV with the cursor in the most significant digit the rotary control will decrement the offset in 100mV steps as follows DC 205 mV DC 105 mV DC 5 00 mV DC 95 0 mV DC 195 mV The key can also be used at any time to set the offset value negative alternative presses toggle the sign between and Alternatively the sign of the offset can be changed as part of the entry of a new value e g if the offset is 2 00V it can be changed to 100mVbypressing 1 0 0 mV The actual DC offset at the MAIN OUT socket is attenuated by the fixed step output attenuator when this is in use Since it is not obvious when the signal is being attenuated the actual offset is shown in brackets as a non editable field to the right of the set value For example in the display below the pk pk output is n
235. specified on each slave generator s Trigger menu Synchronisation is only possible between generators when the ratio of the master and slave frequencies is rational e g 3kHz can be synchronised with 2kHz but not with 7kHz The most practical use of synchronisation will be to provide outputs at the same frequency or maybe harmonics but with phase differences GX1010 Il 35 36 Il 4 10 2 Connections for Synchronisation The preferred clock connection arrangement is for the rear panel CLOCK IN OUT of the master which will be set to CLOCK OUTPUT to be connected directly to each of the CLOCK IN OUT sockets of the slaves which will be set to PHASE LOCK The alternative arrangement is to daisy chain the slaves from the master using a BNC T piece at each slave connection but reflections can cause clock corruption at the intermediate taps under some circumstances Similarly the preferred synchronising connection is from the rear panel SYNC OUT of the master directly to each of the EXT TRIG inputs of the slaves The alternative arrangement is to daisy chain from each SYNC OUT to the next generator s EXT TRIG in turn this does not give rise to any data integrity problems but cumulative hardware delays will worsen the phase shift accuracy 4 10 3 Generator Set ups Each generator can have its main parameters set to any value with the exception that the ratio of frequencies between master and slave must be rational see Synchr
236. stantes de calibrage stock es dans une EEPROM Le calibrage ne requiert qu un DVM et un compteur de fr quence et ne prend que quelques minutes Le quartz dans la base temps est d j r d mais un vieillissement allant jusqu 5ppm peut avoir lieu au cours de la premi re ann e Etant donn que la vitesse de vieillissement d croit de fa on exponentielle avec le temps il est peut tre int ressant de recalibrer la fin des 6 premiers mois d utilisation Il est peu probable que d autres param tres aient besoin d tre ajust s La calibration ne peut tre entrepris qu une fois que le g n rateur a fonctionn pendant au moins une heure dans les conditions ambiantes normales 3 3 1 Mat riel n cessaire e Voltm tre digital DVM 3 digits avec une pr cision 0 25 DC et une pr cision 0 5 AC 1kHz e Compteur de fr quence capable de mesurer 10 00000MHz et des largeurs d impulsions de 50us a ou 0 1 us Le DVM est connect a MAIN OUT sortie principale et le compteur AUX OUT La pr cision de mesure de fr quence d terminera la pr cision de l horloge du g n rateur et de fa on id ale doit tre 1ppm Il peut tre plus rapide d utiliser un oscilloscope pour les chelons 05 et 15 se reporter la section suivante 3 3 2 Proc dure de Calibration On acc de la proc dure de calibration en appuyant sur la touche bleue EDIT suivie de CAL la fonction shift e de 6 A chaque chelon l affi
237. ster pour 0 1V 0 1mV CAL 13 att nuateur interm diaire 12dB Ajuster pour 1 768V AC 5mV CAL 14 att nuateur interm diaire 20dB Ajuster pour 0 707V AC 1mV CAL 15 O Signaux carr s MA modulation Ajuster pour une sortie minimum d amplitude GX 1010 l 7 3 4 ee CAL 16 CAL 17 CAL 18 CAL 19 CAL 20 Signaux carr s MA maximales Signaux sinus MA maximales Sym trie signaux carr s HF 50 Sym trie signaux carr s HF 75 Calibrage horloge Ajuster pour 10V 10mV Ajuster pour 3 54 VAC 10mV Ajuster pour 50us 0 1us Ajuster pour 75us 0 1us Ajuster pour 10 00000MHz sur MAIN OUT ou 27 48779MHz sur panneau arri re CLOCK IN OUT Ajuster a 1ppm Appuyer sur CONFIRM deux fois afin de stocker les nouvelles valeurs et de sortir du mode de calibration Maintenance Assurez vous de la bonne compatibilit fusible tension Les r f rences fusibles sont pour un fonctionnement en 230V 250 mA T 250 V HPC pour un fonctionnement en 100V ou en 115V 500 mA T 250 V HPC Pour remplacer le fusible d connectez le cordon secteur de la prise d entr e et enlevez la protection fusible sous les broches en abaissant les deux clips avec des tournevis pour que l emplacement soit ouvert facilement Changez le fusible et replacez la protection Note N utiliser pour le remplacement que des fusibles d intensit nominale et du type sp cifi Il est interdit d utiliser d autre fusibles et de court circuiter les p
238. sur ESCAPE renverra l instrument au menu principal le champ FREQuence affichera FREQ WIDEBAND NOISE Les entr es normales du clavier peuvent en fait tre cr es dans le champ de fr quence mais la nouvelle valeur ne sera pas utilis e avant que Noise ait t desactiv nouveau D une fa on similaire les r glages de la sym trie peuvent tre chang s alors que Noise est allum mais ceci n aura aucun effet avant que Noise soit nouveau desactiv Les autres param tres du menu principal peuvent tre chang s normalement l amplitude le d calage et l imp dance de sortie Noise peut aussi tre utilis de la m me fa on que les autres signaux dans les modes GATE et AM essayer d activer un autre mode fera appara tre un message d alerte Operation illegal here m me si l dition normale de tous les autres modes est permise Saut HOP Le fonction HOP permet de sortir jusqu 16 diff rentes formes de signaux en s rie un r gime d termin soit par une horloge interne soit par un d clenchement ext rieur soit par une commande distance soit en appuyant sur la touche MAN SYNC Chaque signal peut tre r gl en fr quence en amplitude et d calage la sym trie est la m me pour chaque s quence et est d finie dans le menu principal avant que HOP soit s lectionn Les seuls changements de fr quences s effectuent phases continues GX 1010 Le HOP est a la fois dit et contr l a partir du me
239. t TRIAN TRIG lt cpd gt TRIGSRC lt cpd gt ZOUT lt nrf gt R gle la fonction de rampe n gative R gle le Bruit NOISE sur lt ON gt ou lt OFF gt R gle la sortie sur lt ON gt lt OFF gt lt NORMAL gt ou lt INVERT gt Fixe le niveau de sortie a lt nrf gt Vpp Fixe le niveau de sortie a lt nrf gt Vrms Fixe la p riode pricipale a lt nrf gt secondes Fixe la phase a lt nrfx gt degr s Fixe la phase a lt nrf gt degr s R gle la fonction positive d impulsion R gle la fonction de rampe positive D finit la nouvelle fonction arbitraire Donn es d une tape dans la s quence D finit une nouvelle fonction escalier R gle la fonction sinus R gle le mode de g n ration de signal carr e sur lt AUTO gt lt HF gt ou lt LF gt R gle la fonction carr e R gle la fonction escalier R gle le mode de balayage sur lt ON gt ou lt OFF gt Fixe la fr quence de d but de balayage lt nrf gt Hz Fixe la p riode de d but de balayage lt nrf gt secondes Fixe la fr quence de fin de balayage lt nrf gt Hz Fixe la p riode de fin de balayage lt nrf gt secondes R gle le type de balayage sur lt LOG gt ou lt LIN gt Fixe la fr quence du marquage de balayage Set lt nrf gt Hz Fixe la p riode du marqueur de balayage lt nrf gt secondes R gle le mode balayage sur lt BTOE gt d but fin ou lt ETOB gt fin d but R gle la source de balayage sur lt CONT gt conti
240. t galement configurer l instrument de mani re pouvoir renvoyer la valeur de ist au contr leur pendant une op ration d appel en parall le La configuration de l instrument s effectue par la transmission d une commande Parallel Poll Configure PPC suivie d une commande Parallel Poll Enable PPE par le contr leur Les bits de la commande PPE sont indiqu s ci dessous bit 7 X Ne joue aucun r le 7 D tection du bit de r ponse 0 bas 1 haut Position de bit de r ponse Exemple Pour renvoyer le bit RQS bit 6 du Status Byte Register en tant que 1 si vrai et en tant que O si faux dans la position de bit 1 en r ponse une op ration d appel en parall le transmettre les commandes suivantes PRE64 lt pmt gt puis PPC suivi de 69H PPE La r ponse d appel en parall le de l alimentation est alors 00h si RQS est 0 et 01h si RQS est 1 Pendant la r ponse d appel en parall le les lignes d interface DIO sont termin es de mani re r sistive terminaison passive Ceci permet des dispositifs multiples de partager la m me position de bit de r ponse en configuration wired AND ou wired OR voir IEEE 488 1 pour plus d informations cet effet 5 1 4 R glages la mise en route La plupart des r glages de l instrument sont stock s dans une m moire vive r manente et ils restent inchang s lorsque l instrument est teint Les valeurs d tat suivantes de l instrument sont r gl es l allumage Status
241. t from the input queue See the STATUS REPORTING CAPABILITIES section for further information The IEEE 488 2 DEADLOCK error is handled as follows If the response formatter is waiting to send a response message and the input queue becomes full then the instrument enters the DEADLOCK state and an error is generated This will cause the Query Error bit to be set in the Standard Event Status Register a value of 2 to be placed in the Query Error Register and the response formatter to be reset thus clearing the output queue The parser will then start parsing the next lt PROGRAM MESSAGE UNIT gt from the input queue See the STATUS REPORTING CAPABILITIES section for further information 5 1 3 3 GPIB Parallel Poll Complete parallel poll capabilities are offered on this generator The Parallel Poll Enable Register is set to specify which bits in the Status Byte Register are to be used to form the ist local message The Parallel Poll Enable Register is set by the PRE lt nrf gt command and read by the PRE command The value in the Parallel Poll Enable Register is ANDed with the Status Byte Register if the result is zero then the value of ist is O otherwise the value of ist is 1 The instrument must also be configured so that the value of ist can be returned to the controller during a parallel poll operation The instrument is configured by the controller sending a Parallel Poll Configure command PPC followed by a Parallel Poll Enable command PPE
242. t is reached values which would have had least significant bits lt 0 1mHz are truncated with further decrements and the precision is consequently lost when the number is incremented again 4 2 1 2 Output Level The second line of the Main menu permits the output level to be set in terms of EMF open circuit voltage or PD potential difference into a matched load or dBm referenced to the specified source impedance Both EMF and PD can be set in terms of peak peak volts Vpp or r m s volts Vrms Note that in both cases the true peak peak or r m s values are shown for the selected waveform even an arbitrary waveform However in the case of GX1010 Vrms the DC Offset see next section is ignored in the calculation and must be taken into consideration by the user if the DC Offset is non zero FREQ 10 00000kHz EMF 20 0 Vpp 50Q DC 0 00mV 0 00mv SYM 50 0 50 0 The desired form of the output level display can be selected whilst the edit cursor is in the parameter name field by stepping through all the options with the DIGIT keys or the rotary control bring the cursor to the parameter name field first if necessary by pressing EMF PD or by using the FIELD keys With the appropriate parameter form selected the value is entered as a number followed by units e g 100mV can be entered as 1 0 0 mV or 1 V etc The software acts intelligently in certain situations for example even if EMF or PD is the selected parameter
243. t nrf gt Hz for completeness only Set main generator period to lt nrf gt seconds for completeness only Set FSK frequency B to lt nrf gt Hz Set FSK period B to lt nrf gt seconds Set FSK source to lt EXT gt lt MAN gt or lt TGEN gt Set trigger generator period to lt nrf gt seconds Executes a trigger which will have the same effect as pressing the MAN SYNC key MAN REMOTE trigger source Il 47 must be selected first GPIB Group Execute Trigger command GET will perform the same function as TRG 5 2 7 Staircase and Arbitrary Waveforms STAIR SETSTAIR lt nrf gt lt nrf gt ARB SETARB lt nrf gt lt nrf gt ARBSAV lt nrf gt lt cpd gt ARBRCL lt nrf gt ARB Set staircase function Define a new staircase function Up to 16 pairs of length and level may be specified valid length range 0000 to 1024 valid level 512 to 511 Set arbitrary function Define a new Arbitrary function 1024 values must be specified to set the waveform each one a level in the range 512 to 511 Save arbitrary waveform to store lt nrf gt with name lt character data gt The maximum length of the name is 16 characters N B If it is required to retain a waveform sent by a SETARB command ARBSAV must be used immediately after SETARB If this is not done any other ARB operation except ARB will will destroy the data The waveform data will also be lost at power down unless it is saved first Recall a
244. t termin Se reporter la section Consid rations de dur e 4 8 3 Lancer la S quence HOP Pour lancer la s quence saut HOP le curseur edit doit tre positionn dans le champ HOP le fait d appuyer en alternant les touches DIGIT fera basculer HOP entre ON et OFF Avec HOP ON le curseur est supprim et il n est pas possible de faire des changements Sortir de HOP en appuyant sur ESCAPE le champs HOP passe automatiquement sur OFF et ram ne le g n rateur aux r glages utilis s avant que HOP ait t s lectionn Quand le mode saut HOP est actif l affichage HOP propose les param tres du signal pour chaque chelon qui est entr manuellement ou qui a une dur e gt 500ms l afficheur ne suivra pas les changements des chelons plus courts ou des chelons d clanch s de fa on externe 4 8 4 Consid rations de Dur e Le temps pris fixer les param tres d un signal pour chaque chelon d pend de la nature du changement Les dur es approximatives pour chaque changement partir de la face de d clenchement sont les suivants e Seulement la fr quence 0 5ms les changements de fr quences sont en phase continue e Fr quence et forme de signal 3ms mais plus long si le filtre est allum e Amplitude et d calage Jusqu 40ms Si les r glages de la nouvelle amplitude comprennent un changement d att nuateur la sortie est inactive pendant 45ms pendant que le changement a lieu afin d emp cher de
245. ter the number and units ns us ms or s in the same way as for frequency Note that the precision of a period entry is restricted to 6 digits 7 digits are displayed but the last significant one is always zero The hardware is always programmed in terms of frequency when a period entry is made the synthesised frequency is the nearest equivalent value that the frequency resolution and a 6 digit conversion calculation gives If the frequency is displayed after a period entry the value may differ by a digit from the expected value because of these considerations Further once the setting has been displayed as a frequency converting back again to display period will give an exact 6 digit equivalent of the 7 digit frequency but this may differ by a digit from the period value originally entered If the edit cursor is moved to the numeric field turning the rotary control will increment or decrement the numeric value in steps determined by the edit position within the field The FIELD keys move the cursor to the field and the DIGIT keys move it within the field this is more fully explained in the Principles of Editing section Lastly with the edit cursor in the units field pressing the DIGIT keys or turning the rotary control will change the value in decade increments the decimal point will move and or the units will change as appropriate Full 7 digit precision is maintained as the value is decremented until the 0 1mHz resolution limit of the instrumen
246. the Execution Error Register Bit 3 Not used Bit 2 Query Error Set when a query error occurs The appropriate error number will be reported in the Query Error Register as listed below 1 Interrupted error GX1010 2 Deadlock error 3 Unterminated error Bit 1 Not used Bit O Operation Complete Set in response to the OPC command 5 1 5 2 Status Byte Register and Service Request Enable Register These two registers are implemented as required by the IEEE std 488 2 Any bits set in the Status Byte Register which correspond to bits set in the Service Request Enable Register will cause the RQS MSS bit to be set in the Status Byte Register thus generating a Service Request on the bus The Status Byte Register is read either by the STB command which will return MSS in bit 6 or by a Serial Poll which will return RQS in bit 6 The Service Request Enable register is set by the SRE lt nrf gt command and read by the SRE command Bit 7 Not used Bit 6 RQS MSS This bit as defined by IEEE Std 488 2 contains both the Requesting Service message and the Master Status Summary message RQS is returned in response to a Serial Poll and MSS is returned in response to the STB command Bit 5 ESB The Event Status Bit This bit is set if any bits set in the Standard Event Status Register correspond to bits set in the Standard Event Status Enable Register Bit 4 MAV The Message Available Bit This will be set when the inst
247. the MAN SYNC key MAN REMOTE trigger source must be selected first GPIB Group Execute Trigger command GET will perform the same function as TRG Set beep mode to lt ON gt lt OFF gt lt WARN gt or lt ERROR gt Sound one beep GX1010 RCL lt nrf gt RST SAV lt nrf gt 5 2 11 Status Commands LRN LRN lt character data gt EER QER CLS ESE lt nrf gt ESE ESR IST OPC OPC PRE lt nrf gt PRE SRE lt nrf gt SRE Recalls the instrument set up contained in store number lt nrf gt Valid store numbers are 0 9 Recalling store 0 sets all parameters to the default settings see DEFAULT INSTRUMENT SETTINGS Resets the instrument parameters to their default values see DEFAULT INSTRUMENT SETTINGS Saves the complete instrument set up in the store number lt nrf gt Valid store numbers are 1 9 Returns the complete set up of the instrument as a hexadecimal character data block approximately 842 bytes long To re install the set up the block should be returned to the instrument exactly as it is received The syntax of the response is LRN lt Character data gt lt rmt gt The settings in the instrument are not affected by execution of the LRN command Install data for a previous LRN command Query and clear execution error number register The response format is nr1 lt rmt gt Query and clear query error number register The response format is nri lt
248. the peaks the amplitude of the flat portions depends on the PHASE Following on from the previous examples Set FREQ 2 0 kHz Press EDIT TRIG to select the Trigger menu Move the edit cursor to the PHASE field and use the rotary control to adjust the phase which will vary the amplitude of the flat portion creating variable overshoot MAN MAN PER PERX gt x SYM gt gt gt 1 SYM 4 TGEN PERIOD gt lt __ TGEN PERIOD gt DDS Operation and Further Waveform Considerations This section gives some further information on DDS operation as a background to understanding both the advantages and limitations of DDS waveform generation 6 5 1 DDS Operation ADDRESS One complete cycle of the selected waveform is stored in RAM as 1024 10 bit amplitude GX1010 values As the RAM address is incremented the waveform values are output sequentially to a Digital to Analogue Converter DAC which reconstructs the waveform as a series of voltage steps Sinewaves and triangles are subsequently filtered to smooth the steps in the DAC output The frequency of the output waveform is determined by the rate at which the RAM addresses are changed in a DDS system the address changes are generated as follows The RAM contains the amplitude values of all the individual points of 1 cycle 360 of the waveform each sequential address change corresponds t
249. the phase to compensate for the hardware delays 4 4 4 Gated Mode Gated mode is turned on and off with alternate presses of the GATE key the lamp beside the key lights when gate mode is on The selection of the gate source signal is made from the gate edit menu which is selected by pressing the blue EDIT key followed by the GATE key when gate edit is selected the lamp beside the GATE key flashes to show edit mode regardless of whether gate operation is currently selected to be on or off SOURCE EXT TGEN 1 00ms 1 000kHz 4 4 4 1 Gate Source With the edit cursor in the SOURCE field of the gate edit menu the digit keys or rotary control can be used to select EXTernal MAN REMOTE or Trigger GENerator as the gate source In all cases when the gate condition is true the main generator signal is gated through to the MAIN OUT socket Since the main generator is free running and not synchronised with the gate source the start and stop phase of the waveform is entirely GX1010 4 5 arbitrary there will be an instantaneous transition from to the DC Offset level to from the current waveform phase at the start stop of the gating period With the source set to EXTernal the generator waveform is gated on whilst the external signal applied to the EXT TRIG input exceeds the gate threshold 1 5V see External Trigger Input section With the source set to MAN REMOTE the generator waveform is gated on and off with alternate presses of the
250. tor is currently set as the source on the GATE FSK AM or TRIG menus respectively in addition to the menu currently displayed Special Waveforms 4 7 1 Staircase Staircase or multilevel squarewaves are selected by pressing the STAIR key when STAIR is selected the lamp beside the key lights The default staircase is a 4 level waveform with level changes at 90 intervals to modify or define a new staircase select the staircase edit menu by pressing the blue EDIT key followed by STAIR When staircase edit is selected the lamp beside the STAIR key flashes to show edit mode selecting edit mode always sets staircase on and symmetry to 50 to permit visual checking of the waveform GX1010 Il 29 30 Il VALS ABS AUTO YES STEP 00 ACTIVE LENGTH 0256 LEVEL 511 The staircase edit menu is shown above Up to 16 steps can be defined numbered 00 to 15 with a length and level specified either in absolute terms or as a percentage of full scale height and cycle length When the value is set to ABSolute in the VALS field the LENGTH field will accept numbers in the range 0000 to 1024 the cycle sample length and the LEVEL field will accept values in the range 512 to 511 e 10 bit resolution peak peak 512 and 511 correspond to 10V and 10V peaks respectively with the amplitude on the Main menu set to maximum but note that the actual peak peak voltage will be determined by the actual amplitude setting When the value is set to MAX
251. trary waveforms are selected high frequency mode can however be forced by setting AUX OUTPUT HIGH FREQ Note that there is some second order interaction between the Squarewave Generation Filter and Auxiliary Output settings which demand a little thought before deviations from the default conditions are defined For example if SQWAVE GEN and AUX OUTPUT options are set to AUTO but FILTER is set to OFF the edges of both the MAIN OUT and AUX OUT squarewaves will exhibit some jitter at high frequencies e g 1MHz because the sinewave driving the comparator from which both are derived will itself be jittery 4 2 3 4 Frequency Stop In the default mode of FSTOP OFF there are no frequency limits on any waveform and the frequency and waveform can be set as described in the Main Generator section waveform quality will however deteriorate progressively as the frequency increases for certain waveforms as discussed in the DDS Principles section With FSTOP ON the maximum settable frequency for triangle ramp staircase and arbitrary is limited to 100kHz Error messages will be shown if either an attempt is made to enter a frequency above 100kHz whilst one of these waveforms is selected or if an attempt is made to select one of these waveforms with the frequency already set above 100kHz This mode is useful in ensuring that frequencies are not accidentally set too high for waveforms whose quality will deteriorate above 100kHz 4 2 3 5 Trigger Sweep Output
252. u appropri pour obtenir la profondeur de modulation requise Si le niveau sortie du g n rateur est chang l amplitude du signal modulant devra tre chang e pour maintenir la m me profondeur de modulation Comme avec AM interne le r glage de sortie maximale du g n rateur auquel la distorsion est vit e est r duit de 20Vpp EMF 10Vpp EMF quand la modulation passe de 0 100 La gamme de fr quence est DC 100kHz GX 1010 4 6 Le circuit de contr le amplitude du g n rateur a quatre fonctionnements a quadrants autorisant la sortie g n rateur a tre invers e si la tension VCA externe est pris suffisamment n gative La modulation porteuse supprim e SCM peut tre r alis e en appliquant un signal modulant avec un offset n gatif entre OV et 3V d pendant du r glage de niveau de sortie suffisant pour r duire la sortie porteuse z ro Il est aussi possible de moduler un niveau DC partir du g n rateur avec un signal appliqu VCA IN comme suit R gler le g n rateur O Hz signal sinusoidale dans le menu principal et une phase de 90 sur le menu d clenchement Trigger S lectionnez EXT TRIG d faut et activez le mode trigger avec le touche TRIG mais n appliquez pas de signal d clencheur MAIN OUT est maintenant r gl e a la tension cr te positive d finie par le r glage d amplitude dans le menu principal la phase de r glage a 90 sur le menu Trigger donnera la tension n gative cr
253. u bit niveau haut des diff rents caract res Les commandes acceptent des minuscules et des majuscules 5 1 7 Formats de commande a distance GPIB Les entr es GPIB de l instrument sont accumul es dans une file d attente d entr es de 256 octets Celle ci est remplie par interruptions d une fa on transparente aux autres fonctionnements de l instrument Cette file d attente contient des donn es pures syntaxe non analys e prises par l analyseur de syntaxe selon les besoins Les commandes et interrogations sont ex cut es dans l ordre et l analyseur de syntaxe ne commence pas de nouvelle commande avant qu une commande ou interrogation pr c dente soit effectu e II n y a pas de file d attente de sortie ce qui veut dire que la mise en forme de r ponse attend ind finiment le cas ch ant que l instrument soit adress de fa on recevoir et que le message de r ponse complet ait t transmis avant que l analyseur puisse commencer la commande suivante de la file d attente d entr e Les commandes sont transmises en tant que lt PROGRAM MESSAGES par le contr leur et chaque message est constitu de z ro l ment ou de plus d l ments lt PROGRAM MESSAGE UNIT gt s par s par les l ments lt PROGRAM MESSAGE UNIT SEPARATOR gt Les lt PROGRAM MESSAGES gt sont s par s par des l ments lt PROGRAM MESSAGE TERMINATOR constitu s d un des caract res suivants NL Caract re de nouvelle ligne OAH NL ENDCaract re d
254. uery and clear execution error number register Set output level to nrf emf Vpp Set output level to lt nrf gt emf Vrms Set filter mode to lt AUTO gt lt ON gt or lt OFF gt Set main frequency to lt nrf gt Hz Set FSK mode to lt ON gt or lt OFF gt Set main generator frequency to lt nrf gt Hz for completeness only Set FSK frequency B to lt nrf gt Hz Set main generator period to completeness only Set FSK period B to lt nrf gt seconds Set FSK source to lt EXT gt lt MAN gt or lt TGEN gt Set gate mode to lt ON gt or lt OFF gt Set gate source to lt EXT gt lt MAN gt or lt TGEN gt Set HOP status to lt RUN gt or lt OFF gt with last step set to lt nrf gt Install data for a previous LRN command Set negative pulse function Set negative ramp function Set NOISE lt ON gt or lt OFF gt Set output lt ON gt lt OFF gt lt NORMAL gt or lt INVERT gt Set output level to lt nrf gt pd Vpp Set output level to lt nrf gt pd Vrms Set main period to lt nrf gt seconds Set phase to lt nrfx gt degrees lt nrf gt seconds for Il 51 PHASE lt nrf gt POSPUL POSRAMP SETARB lt nrf gt lt nrf gt SETHOP lt nrf gt lt nrf gt lt nrf gt lt nrf gt lt cpd gt lt nrf gt SETSTAIR lt nrf gt lt nrf gt SINE SQRWAVGEN lt cpd gt SQUARE STAIR STAIR SWEEP lt cpd gt SWPBEGFRQ lt nrf gt SWPBEGPER lt nrf gt SWPENDFRQ lt nrf gt SWPENDPER lt nrf gt
255. utilis par les fonctions Trigger Porte GATE FSK et AM et peut tre r gl dans leurs menus respectifs une zone d information est affich e entre parenth ses c t de TGEN quand celui ci est choisi comme source Cette zone affichera FREE quand TGEN n est pas utilis autre part une des lettres G F A T pour indiquer que le g n rateur est d sormais r gl comme source sur le menu PORTE GATE FSK AM ou TRIG en plus du menu affich Signaux Sp ciaux 4 7 1 Escalier Les signaux carr s escalier ou multi niveaux sont s lectionn es en appuyant sur la touche STAIR quand STAIR est s lectionn la DEL cot de la touche s allume L escalier par d faut est un signal 4 niveaux avec des changements de niveau des intervalles de 90 pour modifier ou d finir un nouvel escalier s lectionnez le menu edit escalier en appuyant sur la touche bleue EDIT suivie de STAIR Quand le menu escalier est s lectionn la DEL cot de la touche STAIR clignote pour montrer le mode edit s lectionner le mode edit allume toujours le mode escalier et r gle la sym trie sur 50 afin de permettre de v rifier de fa on visuelle le signal VALS ABS AUTO YES STEP 00 ACTIVE LENGTH 0256 LEVEL 511 Le menu edit escalier est montr ci dessus 16 chelons peuvent tre d finis num rot s de 00 15 avec une longueur et un niveau sp cifi soit en termes absolus soit sous la forme d un pourcentage de hauteur et
256. uvant tre connect s entre eux d pend de l organisation des horloges de la longueur des cables etc mais normalement aucun probl me ne devrait tre rencontr jusqu quatre g n rateurs 4 10 1 Principes de Synchronisation Le verrouillage de fr quence se fait en utilisant une sortie horloge du g n rateur maitre pour piloter les entr es horloge des esclaves La connexion en plus d un signal SYNC initialisant permet chaque esclave d tre synchronis de fa on ce que la relation de phase entre ma tre et esclave soit celle sp cifi e sur chaque menu Trigger d clenchement du g n rateur esclave La synchronisation est seulement possible entre des g n rateurs si le quotient des fr quences du maitre et de l esclave est rationnel Par exemple 3 kHz peut tre synchronis avec 2 kHz mais pas avec 7kHz L utilisation la plus pratique de la synchronisation est de pr voir des sorties ayant la m me fr quence ou des harmoniques mais avec des d phasages 4 10 2 Connexions pour la Synchronisation La connexion d horloge la plus utilis e est de relier le CLOCK IN OUT situ sur le panneau arri re du maitre qui sera r gl sur CLOCK OUTPUT directement chaque CLOCK IN OUT des esclaves qui seront r gl s sur PHASE LOCK L autre possibilit est de faire GX 1010 une chaine lin aire des esclaves a partir du maitre en utilisant des BNC en T pour chaque connexion esclave Mais dans ce cas les r flexions peuvent en
257. vation de demande de service Ces deux registres sont exploit s selon les imp ratifs d IEEE Std 488 2 Tous les bits r gl s dans le Status Byte Register qui correspondent aux bits r gl s dans le Service Request Enable Register entra nent le r glage du bit RQS MSS dans le Status Byte Register ce qui produit un Service Request sur le bus GX 1010 Le Status Byte Register est lu soit par la commande STB qui renvoie MSS dans le bit 6 soit par un Serial Poll qui renvoie RQS dans le bit 6 Le Service Request Enable Register est r gl par la commande SRE lt nrf gt et lu par la commande SRE Bit7 Non utilis Bit 6 RQS MSS Ce bit d fini par IEEE Std 488 2 contient le message Requesting Service ainsi que le message Master Status Summary RQS est renvoy en reponse a une commande Serial Poll et MSS en r ponse a la commande STB Bit 5 ESB The Event Status Bit Ce bit est r gl si des bits r gl s dans le Standard Event Status Register correspondent aux bits r gl s dans le Standard Event Status Enable Register Bit4 MAV The Message Available Bit Il est r gl lorsque l instrument a un message de r ponse mis en forme et pr t a tre transmis au contr leur Le bit est r initialis apr s transmission du Response Message Terminator Bit3 Non utilis Bit2 Non utilis Bit1 Non utilis BitO Non utilis POWER ON COMMAND ERROR EXECUTION ERROR ERROR NUMBER IN EXECUTION ERROR REGISTER EER REA
258. vec une signal carr e 100kHz augmenter la sym trie au dela de 80 lancera le message SYMMETRY TOO WIDE FOR FUNC FREC Le r glage sera accept mais GX 1010 l 17 18 la sym trie r elle sera limit e 80 comme il est indiqu entre parenth ses c t du r glage Si un r glage hors sp cifications est r alis en passant la fr quence en dessous de 30 kHz ou en changeant la forme du signal alors l alerte SYMMETRY CHANGED BY FUNC FREC est affich e Les messages ERROR sont affich s quand un r glage ill gal est tent le plus g n ralement un param tre au del des valeurs permises Dans ce cas l entr e n est pas valid e et le r glage des param tres est inchang Les exemples sont 1 Entrer une fr quence de 100Mhz Le message d erreur FREQUENCY PERIOD VAL OUT OF RANGE appara t 2 Entrer un EMF de 25V cr te cr te Le message d erreur MAX OUTPUT LEVEL EXCEEDED apparait 3 Entrer un offset DC de 20V Le message d erreur MAX DC OFFSET EXCEEDED apparait Les messages apparaissent pendant environ deux secondes Les deux derniers messages peuvent tre revus en pressant la touche bleue EDIT suivi de MSG touche 0 Chaque message a un nombre et la liste compl te est dans l annexe 1 avec de plus amples explications la ou le message n est pas clair Le r glage par d faut est pour tous les messages d erreur a afficher et pour le beep sonore accompagnant Ce r glage
259. vent tre r gl es avec une haute r solution de mHz a Mhz e Bruit de phase et distorsion bas e Des balayages de fr quence tr s larges sont possibles e Commutation de fr quence continue phase rapide e G n ration facile de signaux non standards tels que les signaux carr s multi niveaux e Possibilit de signal arbitraire de base dans le m me instrument De plus il est plus facile de programmer chaque param tre par clavier ou par commande via les interfaces RS 232 et GPIB La limite fondamentale de la technique DDS est que lorsque la fr quence augmente le nombre d chantillons par cycle diminue Ce n est pas un probl me pour les sinuso des qui filtr es peuvent tre produites avec une faible distorsion jusqu la limite de fr quence du g n rateur Avec les signaux impulsions et carr s l incertitude d un cycle pose une limite pratique aux fr quences sup rieures Cependant sur cet instrument la technique de g n ration change 30kHz pour utiliser un comparateur pilot par la sinusoide DDS ceci assure des signaux carr s sans Jitter et des impulsions jusqu la fr quence limite du g n rateur Les signaux rampe et escalier sont par d faut non filtr s le filtrage peut tre choisi et ainsi sont d grad s au dessus des fr quences indiqu es dans les sp cifications tous les signaux sont cependant disponibles jusqu la fr quence maximum du g n rateur 4 1 2 Mise en marche Le bouton
260. with miniature screwdrivers so that the drawer can be eased open Change the fuse and replace the drawer The use of makeshift fuses or the short circuiting of the fuse holder is prohibited For problems concerning maintenance spare parts warranty etc please contact your METRIX local agency This organisation will quickly process orders for spare parts and will help you towards a quick repair and calibration service NOTE The replacement fuse must be the same size and rating as the fuse supplied GX1010 4 1 FUNCTIONAL DESCRIPTION This section is a general introduction to the features and organisation of the function generator intended to be read before using the instrument for the first time Detailed operation is covered in later sections starting with Main Generator Operation General 4 1 1 DDS Principles In this instrument waveforms are generated by Direct Digital Synthesis DDS One complete cycle of the waveform is stored in RAM as 1024 10 bit amplitude values As the RAM address is incremented the waveform values are output to a Digital to Analogue Converter DAC which reconstructs the waveform Sinewaves and triangles are subsequently filtered to smooth the steps in the DAC output The frequency of the waveform is determined by the rate at which the RAM addresses are changed Further details of how this rate is varied i e how the frequency is changed are given later in the DDS Operation section it is suffi
261. x de signaux carr es escaliers signaux de drivers LCD multiplexe etc Gamme de fr quences Tous les points de signal peuvent tre sortis en continu jusqu environ 27kHz au dessus chantillonnage introduira une incertitude d un cycle d horloge 1 cycle 36ns Niveau de sortie 5mV 20V cr te cr te circuit ouvert o p Temps de mont e et descente lt 25ns e Arbitraire Un certain nombre de signaux fr quemment rencontr es est pr programm dans la ROM Sinon des formes de signal peuvent tre charg es via interface RS 232 ou GPIB et stock es dans la RAM non volatile Gamme de fr quences Tous les points de signal peuvent tre sortis en continu jusqu environ 27kHz au dessus desquels ils sont chantillonn s Niveau de sorite 5mV a 20V cr te cr te circuit ouvert o p Nombre d chantillons 1024 Niveaux d chantillonnage 1024 10 bits e Saut HOP Jusqu a 16 formes de signal diff rentes peuvent tre sorties en s quence a une vitesse d termin e par l horloge interne soit un d clencheur externe soit une t l commande soit par le clavier Chaque signal peut tre r gl e une forme quelconque except le bruit fr quence amplitude d calage Seul les changements de fr quence sont en phase continue e Bruit La sortie bruit blanc a une largeur de bande a 3dB de 0 03Hz a 700kHz Amplitude et d calage ajustables Le bruit ne peut tre utilis qu avec les modes porte
262. x du mode signaux carr s LF de m me fr quence car le signal sinusoidal entra nant le comparateur est retard e de fa on significative par le filtre e R gler les signaux carr s impulsion sur le mode LF de plus hautes fr quences am nera une incertitude d un front de cycle sur les sorties AUX m me s il est toujours r gl sur AUTO ou HF car maintenant le comparateur est pilot par une forme de signal LF mode au lieu d un signal sinuso dale filtr 6 5 2 3 Modes de fr quence pour Balayage et FSK Pour les op rations Balayage et FSK les modes de signal MAIN et AUX sont fixes sur HF ou LF m me si le r glage du menu Options est AUTO Le r glage dans ces circonstances est celui du g n rateur principal avant que Balayage ou FSK soient allum s Par exemple si les deux fr quences FSK sont 25kHz et 50kHz et que 25 kHz ait t la fr quence du g n rateur principal avant que FSK ait t allum les formes de signaux FSK seront dans le mode de fr quence LF Dans les deux cas le choix automatique peut tre limin et remplac en s lectionnant HF ou LF au lieu de AUTO dans les champs SQWAVE GEN et AUX du menu Options 6 5 2 4 Formes de signaux Asym triques L interaction de l ajustement de la sym trie et de la phase start stop de salve de d clenchement donne des formes de signaux difficiles anticiper En principe le fait d ajuster la sym trie d place le point de phase 180 de la position 50 50 de sym trie 50
263. xternal Trigger Input section With the source set to MAN REMOTE a burst can be initiated by pressing the front panel MAN SYNC key or by the appropriate command via the RS232 or GPIB interfaces With the source set to TGEN the burst is triggered internally as described in the Internal Trigger Generator section The period of the internal generator is set in the TGEN field on the second line of the edit menu With the cursor in the numeric field the DIGIT keys will move the cursor within the field and the rotary control will change the value in increments determined by the cursor position with the cursor in the units field the DIGIT keys or rotary control will change the value in decade increments Direct keyboard entries number plus units will be accepted with the cursor in either field Beside the generator period value the equivalent frequency is shown this is for information only and is not an editable field Because the internal trigger generator can be used by the trigger gate FSK and AM functions and can be set from their respective edit menus an information field is displayed in brackets beside TGEN when this is selected as the source This field will show FREE when TGEN is not used elsewhere or any of the letters G F A T to indicate that the generator is currently set as the source on the GATE FSK AM or TRIG menus respectively in addition to the menu currently displayed 4 4 3 2 Burst Count The number of complete cycles in
264. z 4 4 4 1 Source Porte Avec le curseur dans la zone SOURCE du menu porte les touches DIGIT ou la molette permettent de choisir EXTerne MAN REMOTE ou TRIG GEN comme source GATE Dans tous les cas quand la condition gate est r alis e le signal g n rateur principal est port a la borne MAIN OUT Si le g n rateur principal n est pas synchronis avec la source Porte GATE la phase de d part et d arr t du signal est enti rement arbitraire il y aura une transition instantan e au niveau offset DC vers la phase du signal au d part de la p riode d clenchement p riodique et un instantan au niveau d offset DC l arr t Avec la source r gl e EXTerne le signal g n rateur est d clenche p riodiquement pendant que le signal appliqu l entr e EXT TRIG exc de le seuil porte 1 5V voir section Entr e de d clenchement externe Avec la source r gl e sur MAN REMOTE le signal g n rateur est d clench p riodiquement ouvert ferm par pressions altern es de MAN SYNC ou par une commande via RS232 ou GPIB Avec la source r gl e sur TGEN le signal g n rateur est d clench p riodiquement comme expliqu dans la section g n rateur a d clenchement interne le g n rateur a d clenchement est r gl exactement comme d crit dans la section source de d clenchement Modulation d Amplitude Deux modes de fonctionnement sont disponibles a partir du menu AM e La Modulation d A