Home

LT-100

image

Contents

1. INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MANUEL D INSTRUCTIONS GREENLEE LT 100 999 3293 8 LAMP TESTER o PROBADOR DE BOMBILLAS ELECTRICAS VERIFICATEUR D AMPOULE Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Lea y entienda todas las instrucciones y la informaci n sobre seguridad que aparecen en este manual antes de manejar estas herramientas o darles mantenimiento Lire attentivement et bien comprendre toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil O 1999 Greenlee Textron IM 1431 8 99 K GREENLEE Description The Greenlee LT 100 Lamp Tester is a hand held device intended to test fluorescent lamp ballasts starters capacitors resistors and the following types of lamps e Fluorescent e Low pressure sodium e High pressure sodium e Neon e Mercury e Metal halide The unit can also locate energized conductors for AC voltages between 60 V and 240 V Safety Safety is essential in the use and maintenance of Greenlee tools and equipment This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool Observe all of the safety information provided Purpose This instruction manual is intended to famili
2. REPAIR Reparaci n de instrumentos de verificaci n Para art culos no cubiertos por la garant a tales como los que se han dejado caer o han sido maltratados etc se puede cotizar el costo de la reparaci n a pedido Nota Antes de enviar cualquier instrumento de verificaci n revise por favor las pilas o aseg rese de que est n totalmente cargadas Garantie vie limit e La soci t Greenlee garantit l acheteur d origine de ces produits que ces derniers ne comportent aucun d faut d ex cution ou de mat riau pour la dur e de leur vie utile sauf l usure normale Cette garantie est assujettie aux m mes conditions que celles contenues dans les modalit s et conditions de la garantie limit e standard d un an de Greenlee Pour toutes les r parations d instruments de mesure exp diez l appareil en port pay l adresse suivante Greenlee Textron 4411 Boeing Drive Rockford IL 61109 2932 tats Unis Sur tous les colis inscrivez Attention TEST INSTRUMENT REPAIR R paration d instrument de mesure Lorsque les articles ne sont pas prot g s par une garantie comme si l appareil est chapp s il est soumis un usage abusif etc une soumission pour le prix de r paration sera pr sent e sur demande Remarque Avant de renvoyer un appareil de mesure v rifiez la pile et assurez vous qu elle est charg e au complet For technical assistance 800 435 0786 GREENLEE LLC Greenlee Textro
3. Test the unit on a known functioning circuit or component e Ifthe unit does not function as expected replace the battery e Ifthe unit still does not function as expected send the unit to Greenlee for repair 4 Take the reading from the unit to be tested using the information provided under Lamp Tests and Other Tests Lamp Tests For all lamp tests press the probe tip to the glass body or the lamp base Press and hold the Lamp Test button Touching the base of the lamp during the test can cause incorrect test results Lamp type Tube is defective if Fluorescent tube does not illuminate Low pressure sodium inner tube does not illuminate High pressure sodium illumination in inner tube is not a clean blue line Neon tube does not illuminate Mercury tube does not illuminate evenly Metal halide tube does not illuminate evenly If lamp illuminates with lamp tester but not when installed in an energized fixture the filaments or ballast may be defective The filaments and ballast may be checked with the continuity function If only half of the lamp illuminates touch the probe tip to the second pin If the other half does not illuminate the lamp is defective Intermittent or unstable illumination while in the fixture may indicate a faulty ballast GREENLEE Operation cont d Other Tests Note The Lamp Test button is not used for these tests To test verify Continuity Instruc
4. caja retire la punta de la sonda del circuito De no observarse esta advertencia pueden sufrirse graves lesiones o incluso la muerte 1 Retire la punta de la sonda del circuito 2 Utilice un destornillador peque o retire la caja de la pila ubicada en el lado inferior del probador de la unidad 3 Saque la pila de la caja 4 Reemplace la pila f jese en la polaridad y col quela nuevamente en la caja correspondiente 5 Vuelva a colocar la caja de la pila en su posici n original 21 GREENLEE Description Le v rificateur d ampoule LT 100 de Greenlee est un appareil portatif con u pour v rifier les ballasts de lampes fluorescentes les d marreurs les condensateurs les r sistances et les types d ampoules suivants e Fluorescent e Sodium basse pression e Sodium haute pression e N on e Mercure e Haloide m tallis L appareil peut rep rer les conducteurs sous tension pour des tensions c a allant de 60 240 volts S curit Lors de l utilisation et de l entretien des outils et des quipements de Greenlee votre s curit est une priorit Ce manuel d instructions et toute tiquette sur l outil fournit des informations permettant d viter des dangers ou des manipulations dangereuses li es l utilisation de cet outil Suivre toutes les consignes de s curit indiqu es Dessein Ce manuel d instructions est con u pour que le personnel puisse se familiariser avec le fonctio
5. e Sila unidad no funciona como deber a reemplace la pila e Si sigue sin funcionar como deber a devu lvala a Greenlee a fin de que sea reparada 4 Anote la lectura de la unidad que se va a verificar de acuerdo con la informaci n proporcionada en las secciones Prueba de bombillas el ctricas y Otras verificaciones Prueba de bombillas el ctricas Para probar cualquier tipo de bombilla presione la punta de la sonda contra la superficie de cristal o la base de la bombilla Oprima y mantenga oprimido el bot n Lamp Test Si se toca la base de la bombilla durante la prueba se pueden originar resultados incorrectos Tipo de bombilla El tubo est defectuoso si Fluorescente el tubo no se ilumina Sodio a poca presi n el tubo interior no se ilumina Sodio a alta presi n la iluminaci n en el tubo interior no es limpia presenta una l nea azul Ne n el tubo no se ilumina Mercurio el tubo no se ilumina uniformemente Haluro met lico el tubo no se ilumina uniformemente Si la bombilla se ilumina en el probador pero no cuando se la instala en una l mpara energizada quiz s se deba a que los filamentos o la resistencia est n defectuosos Los filamentos y la resistencia se pueden verificar mediante la funci n de continuidad si s lo se ilumina la mitad de la bombilla coloque la punta de la sonda en el segundo v stago Si la otra mitad no se ilumina la bombilla est defectuo
6. 29 ll i GREENLEE Sp cifications Plage de temp rature 10 50 C 14 122 F Humidit relative 0 70 sans condensation Conditions d entreposage Enlever la pile Pile 9 volts NEDA 1604 JIS 006P ou IEC 6LR61 Cat gorie de protection IP 40 Indicateurs de pile faible ou d charg e e Aucune tonalit continue ne se fait entendre pendant la v rification de la continuit d un cable en bon tat e Le voyant de continuit tension ne brille plus e Le v rificateur de l ampoule ne fonctionne pas si un tube est en bon tat V rificateur de tension Plage de v rification 60 250 V c a Fr quence 40 60 Hz V rification de la continuit Protection contre la surtension 250 V c a c c Plage de v rification 0 5 MQ approximativement Courant de v rification lt 7 mA V rificateur d ampoule Tension de v rification Approximativement 3 kV 160 kHz Courant de v rification lt 200 pA 30 LT 100 Remplacement de la pile AAVERTISSEMENT Avant d ouvrir le bo tier enlever l embout du capteur du circuit Linobservation de cette consigne peut entra ner des blessures graves voire mortelles 1 Retirer lembout du capteur du circuit 2 l aide d un petit tournevis enlever le bo tier de la pile situ sous le bas c t du v rificateur de l appareil 8 Enlever la pile de son bo tier 4 Remplacer la pile suivre la polarit et la remettre da
7. arize all personnel with the safe operation and maintenance procedures for the Greenlee LT 100 Lamp Tester Keep this manual available to all personnel Replacement manuals are available upon request at no charge and GREENLEE are registered trademarks of Greenlee Textron KEEP THIS MANUAL pa LT 100 Important Safety Information SAFETY ALERT SYMBOL This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage The signal word defined below indicates the severity of the hazard The message after the signal word provides information for preventing or avoiding the hazard ADANGER Immediate hazards which if not avoided WILL result in severe injury or death AWARNING Hazards which if not avoided COULD result in severe injury or death ACAUTION Hazards or unsafe practices which if not avoided MAY result in injury or property damage AWARNING Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this tool can result in an accident causing serious injury or death pa GREENLEE Important Safety Information AWARNING Electric shock hazard Contact with live circuits can result in severe injury or death AWARNING Electric shock hazard e Do not use the unit if it is wet or damaged Failure to observe this warni
8. cation peut fausser les r sultats a base Toucher Type d ampoule Le tube est d fectueux si Fluorescent le tube ne s allume pas Sodium basse pression le tube int rieur ne s allume pas Sodium haute pression l int rieur du tube n est pas une ligne bleue claire N on le tube ne s allume pas Mercure le tube ne s allume pas de fa on uniforme Halo de m tallis le tube ne s allume pas de facon uniforme Si l ampoule s allume avec le v rificateur d ampoule mais pas lorsqu elle est install e dans un dispositif d clairage sous tension il se peut que les filaments ou le ballast soient d fectueux Ces derniers peuvent tre v rifi s l aide de la fonction de continuit Si la moiti de l ampoule s allume toucher le capteur avec la deuxi me tige Si l autre moiti ne s allume pas l ampoule est d fectueuse Si Pillumination est instable ou intermittente lorsque l ampoule est dans le dispositif d clairage il se peut que le ballast soit d fectueux 27 GREENLEE Utilisation Suite Autres v rifications Remarque Le bouton de v rification de l ampoule n est pas utilis pour ces tests Pour v rifier Instructions Indications tester Continuit Toucher une extr mit du circuit ou de la composante avec un embout capteur Toucher Toucher autre extr mit avec la main libre lectrode de contact pour compl ter le c
9. esi n e sodio a alta presi n e ne n e mercurio e haluro met lico La unidad tambi n sirve para localizar conductores activados para tensiones alternas de entre 60V y 240V Acerca de la seguridad Es fundamental observar m todos seguros al utilizar y dar mantenimiento a las herramientas y equipo Greenlee Este manual de instrucciones y todas las marcas que ostenta la herramienta le ofrecen la informaci n necesaria para evitar riesgos y h bitos poco seguros relacionados con su uso Siga toda la informaci n sobre seguridad que se proporciona Prop sito de este manual Este manual de instrucciones tiene como prop sito familiarizar a todo el personal con los procedimientos de operaci n y mantenimiento seguros para el Probador de bombillas el ctricas modelo LT 100 de Greenlee Mantenga siempre este manual al alcance de todo el personal Puede obtener copias adicionales de este manual de manera gratuita previa solicitud y GREENLEE son marcas registradas de Greenlee Textron CONSERVE ESTE MANUAL 12 pa LT 100 Importante Informaci n sobre Seguridad S MBOLO DE ALERTA SOBRE SEGURIDAD Este s mbolo se utiliza para indicar un riesgo o pr ctica poco segura que podr a ocasionar lesiones o da os materiales Cada uno de los siguientes t rminos denota la gravedad del riesgo El mensaje que sigue a dichos t rminos le indica c mo puede evitar o prevenir ese riesgo A PELIGRO Peligros inmediat
10. ircuit Tonalit et continuit DEL de tension Diode polarisation directe Toucher Toucher Toucher a cathode avec l embout du capteur anode avec la main libre lectrode de contact pour compl ter le circuit Tonalit et continuit DEL de tension Les autres r sultats indiquent une diode d fectueuse Diode polarisation inverse Toucher Toucher Toucher anode avec l embout du capteur autre cathode avec la main libre lectrode de contact pour compl ter le circuit Aucune indication La tonalit et DEL de conti nuit tension indiquent une diode d fectueuse Conducteur sous tension Toucher du capte Toucher appareil v rifier avec l embout ur lectrode de contact pour compl ter le circuit Tonalit et continuit DEL de tension si la tension c a est 60 250 V 40 60 Hz La DEL de tonalit et de continuit indique la r sistance de 0 5 MQ approximativement Une tonalit plus forte et une DEL plus brillante indiquent une r sistance plus faible 28 LT 100 Usages types Rep rer un conducteur sous tension V rifier une ampoule Remarque Appuyer sur le bouton de v rification de l ampoule Remarque Toucher l lectrode de contact V rifier une diode __ GQ Polarit inverse Polarit directe me esa Remarque Toucher l lectrode de contact
11. n Subsidiary of Textron Inc 4455 Boeing Drive Rockford IL 61109 2988 USA Technical Customer Service International 815 397 7070 Fax 815 397 1391 Customer Service North America 800 435 0786 Fax 800 451 2632 815 397 1865 Canada Fax 800 524 2853
12. ng can result in severe injury or death AWARNING e e Electric shock hazard Do not apply more than the rated voltage between probe tip and earth ground e Do not contact the probe tip Failure to observe these warnings can result in severe injury or death WARNING Do not operate with the case open e Before opening the case remove the probe from the circuit and shut off the unit Failure to observe these warnings can result in severe injury or death BEIC CSN oo IL LT 100 Important Safety Information ACAUTION e Do not attempt to repair this unit It contains no user serviceable parts e Do not expose the unit to extremes in temperature or high humidity See Specifications Failure to observe these precautions can result in injury and can damage the unit IMPORTANT Unless measuring voltage shut off and lock out power Make sure that all capacitors are discharged Voltage must not be present IMPORTANT a Using this unit near equipment that generates electromagnetic interference can result in unstable or inaccurate readings GREENLEE Identification Probe Tip Cover Probe Lamp Test LED Continuity Voltage LED Lamp Test Button o OY O Contact Electrode on reverse side Icons on the Unit Read the instruction manual O Double Insulation LT 100 Operation 1 See Typical Uses for illustrations 2 Remove the probe tip cover 3
13. nnement et les proc dures d entretien s res du v rificateur d ampoule LT 100 de Greenlee Mettre ce manuel la disposition de tous les employ s On peut obtenir des exemplaires gratuits sur simple demande et GREENLEE sont ces marques d pos es de Greenlee Textron CONSERVER CE MANUEL 22 COR 1 ka L1 100 Consignes de s curit importantes SYMBOLE D AVERTISSEMENT Ce symbole met en garde contre les risques et les manipulations dangereuses pouvant entra ner des blessures ou l endommagement du mat riel Le mot indicateur d fini ci dessous indique la gravit du danger Le message qui suit le mot indicateur indique comment emp cher le danger ADANGER Danger imm diat qui s il n est pas pris en consid ration ENTRAINERA des blessures graves voire mortelles AAVERTISSEMENT Danger qui s il n est pas pris en consid ration POURRAIT entra ner des blessures graves voire mortelles AATTENTION Dangers ou manipulations dangereuses qui s ils ne sont pas pris en consid ration POURRAIENT EVENTUELLEMENT entra ner des dommages la propri t ou causer des blessures AAVERTISSEMENT Lire attentivement et bien comprendre cette documentation avant d utiliser ou de proc der l entretien de cet quipement N gliger de comprendre comment utiliser cet outil en toute s curit peut provoquer un accident et entra ner de
14. ns son bo tier 5 Replacer le bo tier de la pile dans son emplacement d origine 31 Lifetime Limited Warranty Greenlee warrants to the original purchaser of these goods for use that these products will be free from defects in workmanship and material for their useful life excepting normal wear and abuse This warranty is subject to the same terms and conditions contained in Greenlee s standard one year limited warranty For all Test Instrument repairs ship units Freight Prepaid to Greenlee Textron 4411 Boeing Drive Rockford IL 61109 2932 USA Mark all packages Attention TEST INSTRUMENT REPAIR For items not covered under warranty such as dropped abused etc repair cost quote available upon request Note Prior to returning any test instrument please check replaceable batteries or make sure the battery is at full charge Garantia limitada de por vida Greenlee garantiza al comprador original de estos productos para su uso que estos productos estar n libres de defectos de mano de obra y materiales durante toda su vida Util exceptuando el desgaste normal y el abuso Esta garantia esta sujeta a los mismos t rminos y condiciones contenidos en la garantia estandar limitada de Greenlee de un afio de duraci n Para reparaci n de instrumentos de verificaci n env e las unidades con flete pagado a Greenlee Textron 4411 Boeing Drive Rockford IL 61109 2932 EE UU Marque todos los paquetes Atenci n TEST INSTRUMENT
15. ors tension et verrouiller la source d alimentation S assurer que tous les condensateurs sont d charg s Aucune tension ne doit tre pr sente IMPORTANT L utilisation de cet appareil proximit d quipements qui g n rent des interf rences lectromagn tiques peut produire des lectures instables ou erron es 25 GREENLEE Identification Capuchon de embout du capteur Capteur DEL de v rification d ampoule DEL de continuit tension Bouton de v rification d ampoule Oe ie Go URS Electrode de contact au verso Ic nes apparaissant sur l appareil Lire le manuel d instructions O Isolation double 26 Utilisation 1 Se reporter aux mesures types pour voir des illustrations 2 Enlever le capuchon du capteur 8 V rifier l appareil sur un circuit ou sur un composant connu e Si l appareil ne fonctionne pas comme pr vu remplacer la pile e Si l appareil ne fonctionne toujours pas comme pr vu le renvoyer Greenlee pou soit r par LT 100 r qu il 4 Lire l appareil v rifier en utilisant les informations fournies dans les sections V rifications d ampoule et Autres v rifications V rifications d ampoule Pour toutes les v rifications appuyer l extr mit du capteur sur le corps en verre ou sur de l ampoule Appuyer sur le bouton de v rification de l ampoule et le maintenir enfonc la base de l ampoule pendant la v rifi
16. os que de no evitarse OCASIONAR N graves lesiones o incluso la muerte AADVERTENCIA Peligros que de no evitarse PODR AN OCASIONAR graves lesiones o incluso la muerte A PRECAUCI N Peligro o pr cticas peligrosas que de no evitarse PUEDEN OCASIONAR lesiones o da os materiales AADVERTENCIA Lea y entienda este documento antes de manejar esta herramienta o darle mantenimiento Utilizarla sin comprender c mo manejarla de manera segura podr a ocasionar un accidente y como resultado de ste graves lesiones o incluso la muerte 13 pa GREENLEE Importante Informacion sobre Seguridad AADVERTENCIA Peligro de electrocuci n El contacto con circuitos activados puede ocasionar graves lesiones o incluso la muerte AADVERTENCIA Peligro de electrocuci n e No utilice esta unidad si se encuentra mojada o da ada De no observarse esta advertencia pueden sufrirse graves lesiones o incluso la muerte AADVERTENCIA Peligro de electrocuci n e No aplique m s del voltaje nominal entre la punta de la sonda y el cable de conexi n a tierra e No toque la punta de la sonda De no observarse estas advertencias pueden sufrirse graves lesiones o incluso la muerte AADVERTENCIA e No haga funcionar esta unidad con la caja abierta e Antes de abrir la caja retire del circuito la sonda y apague la unidad De no observarse estas advertencias pueden sufrirse gra
17. s blessures graves voire mortelles 23 pa Q GREENLEE Consignes de s curit importantes AAVERTISSEMENT Risques de d charge lectrique Un contact avec des circuits sous tension peut entrainer des blessures graves voire mortelles AAVERTISSEMENT Risques de d charge lectrique e Ne pas utiliser cet appareil s il est mouill ou endommag Linobservation de cette consigne peut entra ner des blessures graves voire mortelles e AAVERTISSEMENT e Risques de d charge lectrique e Ne pas appliquer plus que la tension nominale entre embout du capteur et la prise de terre e Ne pas entrer en contact avec l embout du capteur Linobservation de ces consignes peut entra ner des blessures graves voire mortelles AAVERTISSEMENT e Ne pas utiliser lorsque le bo tier est ouvert e Avant d ouvrir le bo tier retirer la sonde du circuit et mettre l appareil hors tension Linobservation de ces consignes peut entra ner des blessures graves voire mortelles 24 LT 100 Consignes de s curit importantes AATTENTION e Ne pas tenter de r parer cet appareil II ne comporte aucune pi ce pouvant tre r par e e Ne pas exposer l appareil des temp ratures ou une humidit extr mes Voir les sp cifications Linobservation de ces consignes peut endommager l appareil et entra ner des blessures IMPORTANT Sauf si l on mesure la tension ou le courant mettre h
18. sa Si la bombilla se ilumina en forma intermitente o inestable cuando est puesta en la l mpara quiz s se deba a que la resistencia est defectuosa 17 GREENLEE Operaci n continuaci n Otras verificaciones Nota El bot n Lamp Test no se utiliza para realizar estas verificaciones Para probar verificar Continuidad Instrucciones Toque un extremo del circuito o componente con la punta de la sonda Toque el otro extremo con la mano Toque el electrodo de contacto para completar el circuito Indicaciones Tono y LED de continuidad tensi n Diodo polarizaci n directa Toque el c todo con la punta de la sonda Toque el nodo con la mano Toque el electrodo de contacto para completar el circuito Tono y LED de continuidad tensi n Otros resultados indican que hay un diodo defectuoso Diodo polarizaci n inversa Toque el nodo con la punta de la sonda Toque el otro c todo con la mano Toque el electrodo de contacto para completar el circuito No hay indicaci n Tono y LED de continuidad tensi n indican que hay un diodo defectuoso Conductor activado Toque con la punta de la sonda la unidad a verificar Toque el electrodo de contacto para completar el circuito de 0 a 5 MQ aproximadamente Un tono mas alto y un LED mas brillante indican una resistencia inferior 18 Tono y LED de continuidad tensi n si la
19. tensi n alterna es de 60 a 250V a 40 a 60 Hz Si se escucha un tono y se ilumina el LED continuidad hay una resistencia LT 100 Aplicaciones m s comunes Localizaci n de conductores activados Prueba de bombillas Nota Toque el electrodo de contacto Verificaci n de diodo polarizacion Q imersa polarizaci n directa Nota Toque el electrodo de contacto 19 Nota Oprima el bot n Lamp Test GREENLEE Especificaciones Escala de temperatura de 10 C a 50 C 14 F a 122 F Humedad relativa 0 a 70 sin condensaci n Condiciones de almacenamiento Retire la pila Pila 9 voltios NEDA 1604 JIS 006P o IEC 6LR61 Categoria de protecci n IP 40 Indicadores de pila baja e Eltono continuo est ausente al realizar una verificaci n de continuidad en un cable que se sabe est en buenas condiciones e La luz de continuidad tensi n ya no se ilumina con brillantez e El verificador de bombillas no funciona en un tubo que se sabe funciona perfectamente Verificador de tensi n Escala de prueba 60 a 250V CA Frecuencia 40 a 60 Hz Verificaci n de continuidad Protecci n de sobretensi n 250V CA CC Escala de prueba 0 a 5 MQ aproximadamente Corriente de prueba lt 7 mA Probador de bombillas Tensi n de prueba Aproximadamente 3 kV 160 kHz Corriente de prueba lt 200 pA 20 LT 100 Como reemplazar la pila AADVERTENCIA Antes de abrir la
20. tions Touch one end of the circuit or component with probe tip Touch the other end with free hand Touch the contact electrode to complete the circuit Indications Tone and Continuity Voltage LED Diode forward bias Touch the cathode with probe tip Touch the anode with free hand Touch the contact electrode to complete the circuit Tone and Continuity Voltage LED Other results indicate a faulty diode Diode reverse bias Touch the anode with probe tip Touch the other cathode with free hand Touch the contact electrode to complete the circuit No indication Tone and Continuity Voltage LED indicate a faulty diode Energized Conductor Touch unit to be tested with probe tip Touch the contact electrode to complete the circuit Tone and Continuity Voltage LED if AC voltage is 60 to 250 V at 40 to 60 Hz Tone and Continuity LED indicate resistance from 0 to 5 MQ approximately Louder tone and brighter LED indicate lower resistance LT 100 Typical Uses Locating an Energized Conductor Testing a Lamp Note Touch the contact electrode Checking a Diode QC Reverse Bias Forward Bias me nr Note Touch the contact electrode Note Press the Lamp Test button GREENLEE Specifications Temperature Range 10 C to 50 C 14 F to 122 F Relative Humidity 0 to 70 noncondensing Storage Conditions Remove ba
21. ttery Battery 9 Volt NEDA 1604 JIS 006P or IEC 6LR61 Protection Category IP 40 Low Battery Indicators e Continuous tone is absent when performing a continuity test on known good wire e Continuity Voltage light no longer glows brightly e Lamp tester does not work on a known functioning tube Voltage Tester Test Range 60 to 250 V AC Frequency 40 to 60 Hz Continuity Verification Overvoltage Protection 250 V AC DC Test Range 0 to 5 MQ approximately Test Current lt 7 mA Lamp Tester Test Voltage Approximately 3 kV 160 kHz Test Current lt 200 pA 10 LT 100 Battery Replacement A WARNING Before opening the case remove the probe tip from the circuit Failure to observe this warning can result in severe injury or death 1 Remove the probe tip from the circuit 2 Using a small screwdriver remove the battery case located on the under side of the tester from the unit 3 Remove the battery from the battery case 4 Replace the battery observe polarity and return it to the battery case 5 Replace the battery case to its original position 11 GREENLEE Descripci n El Probador de bombillas el ctricas modelo LT 100 de Greenlee es un dispositivo de bolsillo que cabe perfectamente en la palma de la mano y est dise ado para probar resistencias de bombillas fluorescentes encendedores condensadores resistores y los siguientes tipos de bombillas e fluorescentes e sodio a poca pr
22. ves lesiones o incluso la muerte 14 BEIC CSN oo IL LT 100 Importante Informaci n sobre Seguridad PRECAUCI N e No intente reparar esta unidad ya que contiene piezas que deben recibir mantenimiento por parte de un profesional e No exponga esta unidad a ambientes de temperatura extrema o altos niveles de humedad consulte las Especificaciones De no observarse estas precauciones podr an sufrirse lesiones o da os a la unidad IMPORTANTE A menos que vaya a medir voltaje apague y bloquee la energ a Aseg rese de que todos los condensadores est n totalmente sin carga No debe haber voltaje alguno e IMPORTANTE e Al utilizar esta unidad cerca de equipo que genere interferencia electromagn tica quiz se obtenga una lectura inexacta e inestable 15 GREENLEE Identificaci n Tapa de la punta de la sonda Sonda Diodo Lamp Test probar bombilla Diodo Continuity Voltage continuidad tensi n Bot n Lamp Test probar bombilla SS rap D Electrodo de contacto ubicado al reverso Iconos en la unidad Lea el manual de instrucciones E Doble forro aislante 16 LT 100 Operaci n 1 V ase la secci n Aplicaciones m s comunes para las ilustraciones de las aplicaciones m s comunes 2 Retire la tapa de la punta de la sonda 3 Pruebe la unidad en un circuito o componente que se sabe est funcionando perfectamente