Special Dual Profibus Gateway
Contents
1. J3 RS485 PROFIBUS INTERFACE ADDRESS MSD LSD El STATUS Figure 1 Outline Controller with DIN slide Assembly 32 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C Technical Information 5 Installation This device is designed to work between a profibus network and up to 4 DUAL Agilent controller So a typical network will appear as follow ProfiBus Network DUAL DUAL ProfiBus ProfiBus Gateway n 2 Gateway n 1 RS 485 link RS 485 link DUAL Agilent DUAL Agilent DUAL Agilent DUAL Agilent Controller 1 Controller 2 Controller 3 Controller 4 ADDR 1 ADDR 2 ADDR 3 ADDR 4 Figure 2 Recommended procedure 1 Besure that all the units and controllers are switched off 2 For RS 485 the cabling please refer to following pin out and to the controller s manual the RS 485 cable has to be connected in this way note that only 3 wires are needed and not 5 Special Dual Profibus Gateway User Manual 87 900 115 01 C 33 52 5 Technical Information a a DUAL Agilent as DUAL ProfiBus Gateway Controller DUAL Agilent Controller Figure 3 1 Connect the Profibus cable Set the address by rotational switches on the Profibus gateway 3 To avoid some seconds time delay up to 50 sec after power on due to the controller address s
2. Vacuum leak Main seal leak Solenoid failure OPERATING TIME VALVES COMPONENTS Bellows leak Damaged flange Error code on display Other LEAK DETECTORS Damaged sealing area Other INSTRUMENTS Cannot calibrate No zero high backround Vacuum system unstable Cannot reach test mode Failed to start Other Gauge tube not working Display problem Communication failure Degas not working Error code on display Other SCROLL AND ROTARY VANE PUMPS Pump doesn t start Noisy pump describe DIFFUSION PUMPS Heater failure Doesn t reach vacuum Electrical problem Doesn t reach vacuum Over temperature Cooling coil damage Vacuum leak Other Pump seized Other Section 6 ADDITIONAL TERMS Please read the terms and conditions below as they apply to all returns and are in addition to the Agilent Technologies Vacuum Product Division Products and Services Terms of Sale e Customer is responsible for the freight charges for the returning product Return shipments must comply with all applicable Shipping Regulations IATA DOT etc and carrier requirements e Customers receiving an Advance Exchange product agree to return the defective rebuildable part to Agilent Technologies within 15 business days Failure to do so or returning a non rebuildable part crashed will result in an invoice for the non retumed non rebuildable part e Returns for credit towa
3. 01 C Technical Information 5 Profibus mapping DESCRIPTION Offset Unit res Size byte RS485 cmd E dre eae 35 Afloat ul Pressure HV1 Torr mBar Pa x 39 4float U02 Pressure HV2 Tor mBar Pa Diagnosis Management Standard diagnostic The standard diagnostic management is fully compliant with the Profibus specification Technical Specifications Tab 4 Operating ambient temperature 5 C to 40 C 0 90 relative humidity Power supply n Input voltage TN Max input power 8W 0 Protection fuse T 1A slow blow sss E Compliance with EN 55011 Radio disturbance characteristics EN 61000 6 2 and EN 61326 Immunity for industrial environments which recall EN 61000 4 2 Electrostaticdischarge phenomena EN 61000 4 3 Radiatedhigh frequency phenomena EN 61000 4 4 EN 61000 4 5 EN61000 4 6 Conducted high frequency phenomena EN 61000 4 8 low frequency magnetic field Installation Category Il Pollution Degree S Environment protection IEEE S 9 Q Q II Weight kg Ibs 038 083 0000 Special Dual Profibus Gateway User Manual 87 900 115 01 C 45 52 5 Technical Information Technical Specifications 46 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C d Agilent Technologies Vacuum Products Division Dear Customer Thank you for purchasing an Agilent vacuum product At Agilent Vacuum Products Division we make every effort to
4. Lu Chao Yang District Beijing 100102 China Tel 86 10 6439 7718 Toll Free 800 820 6556 France Agilent Technologies France Vacuum Products Division 7 Avenue des Tropiques Z A de Courtaboeuf B P 12 91941 Les Ulis cedex France Tel 33 0 1 69 86 38 84 Fax 33 0 1 69 86 29 88 Toll free 00 800 234 234 00 Germany and Austria Agilent Technologies Vacuum Products Division Alsfelder Strasse 6 Postfach 11 14 35 64289 Darmstadt Germany Tel 49 0 6151 703 353 Fax 49 0 6151 703 302 Toll free 00 800 234 234 00 Sales and Service Offices India Agilent Technologies India Pvt Ltd Vacuum Product Division G01 Prime corporate Park 230 231 Sahar Road Opp Blue Dart Centre Andheri East Mumbai 400 099 India Tel 91 22 30648287 8200 Fax 91 22 30648250 Toll Free 1800 113037 Italy Agilent Technologies Italia S p A Vacuum Products Division Via F lli Varian 54 10040 Leini Torino Italy Tel 39 011 997 9111 Fax 39 011 997 9350 Toll Free 00 800 234 234 00 Japan Agilent Technologies Japan Ltd Vacuum Products Division 8th Floor Sumitomo Shibaura Building 4 16 36 Shibaura Minato ku Tokyo 108 0023 Japan Tel 81 3 5232 1253 Fax 81 3 5232 1710 Toll Free 0120 655 040 Korea Agilent Technologies Korea Ltd Vacuum Products Division Shinsa 2nd Bldg 2F 966 5 Daechi dong Kangnam gu Seoul Korea 135 280 Tel 82 2 3452 2452 Fax 82 2 3452 2451 Toll Fr
5. ND 15 not installed 5 mA 1 700 B76 Local Remote 0 0 off 0 0 Local 0 1 Remote 1 0 Serial G01 Bs PowerSupply1 polarity 0 negative 1 positive G02 Ba PowerSupply2 polarity 0 negative 1 positive B3 B2 D00 Bio pressure unit 0 0 Torr 0 1 mBar 1 0 Pascal 6 mA 1 K01 protect 1 1 mA 1 K02 protect 2 Special Dual Profibus Gateway User Manual 87 900 115 01 C 43 52 5 Technical Information Profibus mapping 7 7 DESCRIPTION Offset Unit res Size byte RS485 cmd 1 g01 Remote 1 0 output 1 B7 Always 0 Be Protect mode 0 no 1 yes Bs Remote or Local 0 Serial 1 8 Ba HV fault 0 no 1 yes B3 Interlock active 0 no 1 yes B2 Setpoint 1 active 0 no 1 yes Bi Setpoint 2 active 0 no 1 yes Bo High voltage enable 0 no 1 yes 1 g02 Remote 1 0 output 2 B7 Always 0 Be Protect mode 0 no 1 yes Bs Remote or Local 0 Serial 1 9 Ba HV fault 0 no 1 yes B3 Interlock active 0 no 1 yes B2 Setpoint 1 active 0 no 1 yes Bi Setpoint 2 active 0 no 1 yes Bo High voltage enable 0 no 1 yes 1 WIO B MSB Be B5 B4 10 B3 B2 Bi Remote 1 0 interlock polarity 0 normal 1 reversed Bo Auto Power ON 0 no 1 yes 11 4 float P01 SetPt1 HV1 Torr mBar Pa 15 4 float 002 SetPt2 HV1 Torr mBar Pa 19 4 float P02 SetPt1 HV2 Torr mBar Pa 23 4 float 002 SetPt2 HV2 Torr mBar Pa 27 A 4 float T01 meas HV1 44 52 Special Dual Profibus Gateway User Manual 87 900 115
6. User Manual 87 900 115 01 C Technical Information 5 Tab 1 PROFIBUS STATE MACHINE RS485 STATE MACHINE Status Meaning Status Meaning POWER ON Interface setup POWERON Interface setup WAIT_PRM Wait for parameterisation from the SRC ADDR Search for the controller serial _ Pr Lu ju address 0 s E WAIT_CFG Wait for configuration from the IDENTIFY Identify controller model and master Basel 0 cr i uu il The two machines continuously share I O data with the relative bus and interact each other only in following conditions ProfiBus Data exchange is suspended static diagnosis activated if the RS 485 serial link in not established RS 485 Data exchange is suspended only for output data if the ProfiBus State machine is not in Data Exchange mode As a general rule unrecoverable communication errors make each machine to jump to the state immediately following the power on state WAIT_PRM or SRC_ADDR Message Mapping The communication is based on the continuous data exchange capability of the Profibus standard where the master sends continuously the entire slave configuration and reads back the entire slave status For this purpose one Input from slave to master and one Output from master to slave buffers are provided All the needed parameters are mapped inside each buffer The following tables reassume the Profibus parameter access related to the corresponding windows serial protocol for th
7. WIO Flags writable only with HV off B MSB Be Bs B4 B3 B2 Bi Remote 1 0 interlock polarity 0 normal 1 reversed ea Bo Auto Power ON 0 no 1 yes _ 5 4 float P01 HV1 Setpoint 1 Torr mBar Pa 9 4 float 001 HV1 Setpoint 2 Torr mBar Pa dU NES NN I ee 17 4 float Q02 HV2 Setpoint 2 Torr mBar Pa Special Dual Profibus Gateway User Manual 87 900 115 01 C 41 52 5 Technical Information Input Buffer Structure for each Controller Connected on the Network Total buffer length 43 bytes 11 bytes 16 words Tab 3 Profibus mapping 7777 DESCRIPTION Offset Unit res Size byte RS485 cmd 0 1 Device serial address 1 Ibit 1 S01 V meas HV1 100V 2 1bit 1 S02 V meas HV2 100V 3 1 100 Interlock status byte 0 means all interlock present the bit set to 1 means interlock missing B7 HV2 cable interlock Be HV2 remote 1 0 interlock Bs Front panel interlock equal to B B4 Reserved always 0 B3 HV1 cable interlock B2 HV1 remote 1 0 interlock Bi Front panel interlock equal to Bs Bo Reserved always 0 42 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C Technical Information 5 Profibus mapping 77 DESCRIPTION Offset Unit res Size byte RS485 cmd 4 1 F01 B 7 654 Pump type F02 B32 1 0 Pump2 type B7 MSB Pump types 0 Spare 1 500 SC Tr 2 300 SC Tr 3 150 SC Tr 4 75 55 40SC T 5 20 SC Tr 6 500 Diode ND 7 300 Diode ND 8 150 Diode ND 9 75 55 40 D
8. a garantir la s curit de l op rateur pendant l utilisation de l appareillage Des renseignements plus d taill s se trouvent dans l appendice Technical Information Cette notice utilise les signes conventionnels suivants Les messages d avertissement attirent l attention de l op rateur sur une proc dure ou une manoeuvre sp ciale qui effectuee de facon impropre risque de provoquer de graves l sions Les messages d attention apparaissent avant certaines proc dures dont le non respect pourrait endommager s rieusement l appareillage Les notes contiennent des renseignements importants extrapol s du texte Special Dual Profibus Gateway User Manual 87 900 115 01 C Procedure pour l installation 3 Stockage Pendant le transport et le stockage du Profibus Gateway veiller au respect des conditions environnementales suivantes temp rature de 0 C 70 C humidit relative 0 95 non condensante Preparation pour l installation Le Profibus Gateway est livr dans un emballage de protection sp cial en cas d endommagement de l emballage pouvant s tre produit pendant le transport contacter le bureau de vente local Ne pas abandonner l emballage dans la nature Le mat riel est enti rement recyclable et conforme la directive CEE 85 399 en mati re de protection de l environnement Installation Ne pas installer et ou utiliser le Profibus Gateway dans des milieux expos s aux agents atmosp
9. ensure that you will be satisfied with the product and or service you have purchased As part of our Continuous Improvement effort we ask that you report to us any problem you may have had with the purchase or operation of our products On the back side you find a Corrective Action request form that you may fill out in the first part and return to us This form is intended to supplement normal lines of communications and to resolve problems that existing systems are not addressing in an adequate or timely manner Upon receipt of your Corrective Action Request we will determine the Root Cause of the problem and take the necessary actions to eliminate it You will be contacted by one of our employees who will review the problem with you and update you with the second part of the same form on our actions Your business is very important to us Please take the time and let us know how we can improve Sincerely Giampaolo LEVI Vice President and General Manager Agilent Vacuum Products Division Note Fax or mail the Customer Request for Action see backside page to Agilent Vacuum Products Division Torino Quality Assurance or to your nearest Agilent representative for onward transmission to the same address CUSTOMER REQUEST FOR CORRECTIVE PREVENTIVE IMPROVEMENT ACTION TO AGILENT VACUUM PRODUCTS DIVISION TORINO QUALITY ASSURANCE FAX N XXXX 011 9979350 ADDRESS AGILENT TECHNOLOGIES ITALIA S p A Vacuum Products Div
10. ra agilent com EUROPE Toll Free 00 800 234 234 00 vpt customercare agilent com PACIFIC RIM please visit our website for individual office information http www agilent com Worldwide Web Site Catalog and Order On line www agilent com Representative in most countries 12 10
11. 5 link problem e g device is still searching controller 2 pulses Profibus link problem e g device not addressed from a master Blink fast internal error Special Dual Profibus Gateway User Manual 87 900 115 01 C Installation Procedure 4 Profibus Gateway Switching off To switch off the Profibus Gateway it is necessary to remove the mains Maintenance The Profibus Gateway does not require any maintenance Any work performed on the system must be carried out by authorized personnel Before returning the Profibus Gateway to the constructor for repairs or replacement with a reconditioned unit the Health and Safety sheet attached to this instruction manual must be filled in and sent to the local sales office A copy of the sheet must be inserted in the system package before shipping If a Profibus Gateway is to be scrapped it must be disposed of in accordance with the specific national standards Special Dual Profibus Gateway User Manual 87 900 115 01 C 29 52 4 Installation Procedure Disposal Meaning of the WEEE logo found in labels The following symbol is applied in accordance with the EC WEEE Waste Electrical and Electronic Equipment Directive This symbol valid only in countries of the European Community indicates that the product it applies to must NOT be disposed of together with ordinary domestic or industrial waste but must be sent to a differentiated waste collection system The e
12. Special Dual Profibus Gateway Model 829 7016 Manuale di Istruzioni Bedienungshandbuch Notice de Mode D Emploi User Manual 87 900 115 01 C 05 2011 E Agilent Technologies Notices Agilent Technologies Inc 2011 No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or translation into a foreign language without prior agreement and written consent from Agilent Technologies Inc as governed by United States and international copyright laws Manual Part Number Publication Number 87 900 115 01 C Edition Edition 05 2011 Printed in ITALY Agilent Technologies Italia S p A Vacuum Products Division Via F Ili Varian 54 10040 Leini TO ITALY Warranty The material contained in this document is provided as is and is subject to being changed without notice in future editions Further to the maximum extent permitted by applicable law Agilent disclaims all warranties either express or implied with regard to this manual and any information contained herein including but not limited to the implied warranties of merchantability and fitness for a particular purpose Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing use or performance of this document or of any information contained herein Should Agilent and the user have a separate written agreement with warranty ter
13. al Information 26 Storage 21 Preparation for Installation 27 Installation 27 Use 28 Maintenance 29 Disposal 30 Technical Information 31 Introduction 32 Mechanical 32 Installation 33 Profibus Connectors Pin Qut 35 Message Mapping 39 Technical Specifications 45 Special Dual Profibus Gateway User Manual 87 900 115 01 C Special Dual Profibus Gateway User Manual Procedura per l installazione Informazioni Generali 8 Immagazzinamento 9 Preparazione per l installazione 9 Installazione 9 Uso 10 Accensione ed Uso del Profibus Gateway 10 Arresto del Profibus Gateway 11 Manutenzione 11 Smaltimento 12 Traduzione delle istruzioni originali t Agilent Technologies 1 52 1 Procedura per l installazione Informazioni Generali AVVERTENZA ATTENZIONE 8 52 Questa apparecchiatura destinata ad uso professionale L utilizzatore deve leggere attentamente il presente manuale di istruzioni ed ogni altra informazione addizionale fornita dalla Agilent prima dell utilizzo dell apparecchiatura La Agilent si ritiene sollevata da eventuali responsabilit dovute all inosservanza totale o parziale delle istruzioni ad uso improprio da parte di personale non addestrato ad interventi non autorizzati o ad uso contrario alle normative nazionali specifiche Nei paragrafi seguenti sono riportate tutte le informazioni necessarie a garantire la sicurezza dell operatore durante l utilizzo dell apparecchiatura Inform
14. azioni dettagliate sono fornite nell appendice Technical information Questo manuale utilizza le seguenti convenzioni I messaggi di avvertenza attirano l attenzione dell operatore su una procedura o una pratica specifica che se non eseguita in modo corretto potrebbe provocare gravi lesioni personali messaggi di attenzione sono visualizzati prima di procedure che se non osservate potrebbero causare danni all apparecchiatura Le note contengono informazioni importanti estrapolate dal testo Special Dual Profibus Gateway User Manual 87 900 115 01 C Procedura per l installazione 1 immagazzinamento Durante il trasporto e l immagazzinamento del Profibus Gateway non devono essere superate le seguenti condizioni ambientali temperatura da 0 C a 70 C umidit relativa 0 95 non condensante Preparazione per l installazione Il Profibus Gateway viene fornito in un imballo protettivo speciale se s presentano segni di danni che potrebbero essersi verificati durante il trasporto contattare l ufficio vendite locale Non disperdere l imballo nell ambiente Il materiale completamente riciclabile e risponde alla direttiva CEE 85 399 per la tutela dell ambiente Installazione Non installare e o utilizzare il Profibus Gateway in ambienti esposti ad agenti atmosferici pioggia gelo neve polveri gas aggressivi in ambienti esplosivi o con elevato rischio di incendio Durante il funzionamento
15. com http www agilent com Pg 1 3 ATA Agilent Technologies Vacuum Products Division Request for Return Form Health and Safety Certification Please read important policy information on Page 3 that applies to all returns 1 CUSTOMER INFORMATION Tel Fax Customer Ship To Customer Bill To Europe only VAT reg Number USA Canada only C Taxable Non taxable 2 PRODUCT IDENTIFIGATION Product Description Agilent P N Agilent S N Original Purchasing Reference 3 TYPE OF RETURN Choose one from each row and supply Purchase Order if requesting a billable service 3A LI Non Billable Billable mmm New PO hard copy must be submitted with this form 3B Exchange _ Repair _ Upgrade _ Consignment Demo _ calibration _ Evaluation Return for Credit 4 HEALTH and SAFETY CERTIFICATION AGILENT TECHNOLOGIES CANNOT ACCEPT ANY PRODUCTS CONTAMINATED WITH BIOLOGICAL OR EXPLOSIVE HAZARDS RADIGACTIVE MATERIAL OR MERCURY AT ITS FACILITY Call Agilent Technologies to discuss alternatives if this requirement presents a problem The equipment listed above check one HAS NOT pumped or been exposed to any toxic or hazardous materials OR HAS pumped or been exposed to the following toxic or hazardous materials If this box is checked the following information must also be filled out Check boxes for all materials to which product s pumped or was exposed Toxic C Corrosive C Reactive C Flammable Explosive C Bi
16. e green and one red The red led indicates that the interface is correctly powered 36 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C Blink fast Blink slow Figure 6 Technical Information 5 The green led shows the interface status according the following table 1 pulse ProfiBus link established controller link NOT established yet Controller state machine not in Regular data exchange This situation could be normal in the first 45 seconds after the interface power on Controller address searching phase or after the controller power on 2 pulses ProfiBus link not established yet ProfiBus state machine not in Regular data exchange This failure has priority in the indication over the previous Blink fast Gateway fail internal check or wrong address set address gt 0x7D or address not stable during power on Blink slow Gateway operating properly Special Dual Profibus Gateway User Manual 87 900 115 01 C 37 52 5 Technical Information GSD FILE The GSD file provided with this interface is VAVTOS809 gsd The ID number is 0809 hex STATE MACHINE From the software point of view the interface can be seen as two devices one for ProfiBus and the other for RS 485 linked together Each device has its own state machine to manage the device operation Profibus state machine RS485 state machine Power on Power on Figure 7 38 52 Special Dual Profibus Gateway
17. earch phase please follows the advice here below a Configure the DUAL controller to operate in RS 485 mode with a different serial address 01 02 03 04 b Power on the ProfiBus interface only when the controllers are ready to receive data on his serial port internal self test passed 4 Ready to configure your network 34 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C Technical Information 5 Profibus Connectors Pin Out FEMALE CONNECTOR CNT R P RxD TxD N RxD TxD P PROFIBUS ER GND FEMALE CONNECTOR 3 9 4 8 3 y e 6 1 24VDC GND EARTH 4 L COMMON Figure 4 Connectors pin out Special Dual Profibus Gateway User Manual 87 900 115 01 C 35 52 5 Technical Information Dual Connection Example Dual s RS485 connector pin out RS485 CONNECTOR Figure 5 DUAL RS485 Connector Rotary Switches The interface has two switches The switches are used to set the ProfiBus address of the device Up to 126 different addresses from 0 to 125 can be selected The address value sets by the 2 switches is expressed in hexadecimal notation so value from 00 to 7D are permitted this setting is read by the interface during the power on phase so any change of the switch position after the power on is ignored The gateway will answer only at the address set indipendently from the number of Dual connected on RS 485 link Indicators Two LEDs are present on the interface on
18. ee 080 222 2452 Mexico Agilent Technologies Vacuum Products Division Concepcion Beistegui No 109 Col Del Valle C P 03100 Mexico D F Tel 52 5 523 9465 Fax 52 5 523 9472 Singapore Agilent Technologies Singapore Pte Ltd Vacuum Products Division Agilent Technologies Building 1 Yishun Avenue 7 Singapore 768923 Tel 65 6215 8045 Fax 65 6754 0574 Agilent Technologies Inc 2011 Printed in ITALY 05 2011 Publication Number 87 900 115 01 C P Agilent Technologies Southeast Asia Agilent Technologies Sales Sdn Bhd Vacuum Products Division Unit 201 Level 2 uptown 2 2 Jalan 8821 37 Damansara Uptown 47400 Petaling Jaya Selangor Malaysia Tel 603 7712 6106 Fax 603 6733 8121 Taiwan Agilent Technologies Taiwan Limited Vacuum Products Division 3F 20 Kao Shuang Rd Pin Chen City 324 Taoyuan Hsien Taiwan R 0 C Tel 886 34959281 Toll Free 0800 051 342 UK and Ireland Agilent Technologies UK Ltd Vacuum Products Division 6 Mead Road Oxford Industrial Park Yarnton Oxford OX5 1QU UK Tel 44 0 1865 291570 Fax 44 0 1865 291571 Toll free 00 800 234 234 00 Other Countries Agilent Technologies Italia S p A Vacuum Products Division Via F lli Varian 54 10040 Leini Torino Italy Tel 39 011 997 9111 Fax 39 011 997 9350 Toll Free 00 800 234 234 00 Customer Support amp Service NORTH AMERICA Toll Free 800 882 7426 Option 3 vpl
19. h riques pluie froid neige polveri gaz agressifs dans des milieux explosifs ou avec risque lev d incendie Pendant le fonctionnement il est n cessaire de respecter les conditions environnementales suivantes pression maxi 2 bar au del de la pression atmosph rique temp rature de 5 C 40 C humidit relative 0 90 non condensante Special Dual Profibus Gateway User Manual 87 900 115 01 C 21 52 3 Proc dure pour l installation Val Le Profibus Gateway appartient la premi re cat gorie d installations ou Utilisation 22 52 surtension pr vue par la norme EN 61010 1 De ce fait brancher le dispositif une ligne d alimentation compatible avec cette cat gorie Le Profibus Gateway dispose de connecteurs pour les entr es sorties et pour la communication en s rie qui doivent tre branch s aux circuits ext rieurs de facon qu aucune partie sous tension ne soit accessible S assurer que l isolation du dispositif branch au Profibus Gateway a une Isolation appropri e m me en condition de panne individuelle selon les termes de la norme EN 61010 1 Pour l installation des accessoires en option se reporter Technical Information Ce paragraphe pr sente les principales proc dures op rationnelles Avant d utiliser le systeme effectuer tous les branchements lectriques Mise en marche et utilisation du Profibus Gateway Pour allumer le Profibus Gateway il suffit de fourni
20. ions improper use by untrained persons non authorized interference with the equipment or any action contrary to that provided for by specific national standards The following paragraphs contain all the information necessary to guarantee the safety of the operator when using the equipment Detailed information is supplied in the appendix Technical Information This manual uses the following standard protocol WARNING The warning messages are for attracting the attention of the operator to a particular procedure or practice which if not followed correctly could lead to serious injury CAUTION The caution messages are displayed before procedures which if not followed could cause damage to the equipment The notes contain important information taken from the text 26 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C Installation Procedure 4 Storage When transporting and storing the Profibus Gateway the following environmental requirements should not be exceeded temperature from 0 to 70 C relative humidity 0 95 non condensing Preparation for Installation The Profibus Gateway is shipped inside a special protective case in case of damage occurred during the transport please contact the local selling centre Do not throw the case in the environment The material is totally recyclable in accordance with the directive CEE 85 399 for the environmental protection Installation Do no
21. is protocol please refers to the controller s manual Special Dual Profibus Gateway User Manual 87 900 115 01 C 39 52 5 Technical Information The interface doesn t apply any scaling operation on the read written parameters except the floating point format It acts only as a gateway between the ProfiBus network and the controller s serial interface So the user must refer to the instruction manual of the controller connected to the interface to get the correct scale of each parameter Output Buffer Structure for each Controller Connected on the RS 485 Network Total buffer length 21 bytes 5 bytes 8 words Tab 2 Profibus mapping DESCRIPTION byte Unit res Size byte RS485 cmd 0 1 A01 B MSB HV1 on off 0 off 1 on A02 Be HV2 on off 0 off 1 on C01 Bs HV1 protect mode on off 0 off 1 on C02 Ba HV2 protect mode on off 0 off 1 on A01 B3 HV1 mode 0 fixed 1 step A02 B2 HV2 mode 0 fixed 1 step 700 Bio Local Serial Remote Bi Bo Mode 0 0 off 0 0 Local 0 1 Remote 1 0 Serial 1 1 not allowed 1 1 bit 1 K01 HV1 protect writable in step of 10mA and only with 1 mA HV off 2 1 bit 1 K02 HV2 Iprotect writable in step of 10mA and only with 1mA HV off 40 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C Technical Information 5 Profibus mapping DESCRIPTION byte Unit res Size byte RS485 cmd 3 1 D00 B76 Pressure unit B7 Be unit 0 0 Torr 0 1 mBar 1 0 Pascal i 5 nt _ none _ 4 1
22. ision Via F lli Varian 54 10040 Lein TO Italy E MAIL vpd qualityassurance_pdl ext agilent com COMPANY FUNCTION ADDRESS PROBLEM SUGGESTION REFERENCE INFORMATION model n serial n ordering information time to failure after installation etc CORRECTIVE ACTION PLAN ACTUATION by AGILENT VPD XXX Code for dialing Italy from your country es 01139 from USA 00139 from Japan etc Ee Agilent Technologies Agilent Technologies Vacuum Products Division Instructions for returning products Dear Customer Please follow these instructions whenever one of our products needs to be returned 1 2 3 4 9 6 7 Complete the attached Request for Return form and send it to Agilent Technologies see below taking particular care to identify all products that have pumped or been exposed to any toxic or hazardous materials After evaluating the information Agilent Technologies will provide you with a Return Authorization RA number via email or fax as requested Note Depending on the type of return a Purchase Order may be required at the time the Request for Return is submitted We will quote any necessary services evaluation repair special cleaning eg Important steps for the shipment of returning praduct e Remove all accessories from the core product e g inlet screens vent valves e Prior to shipment drain any oils or other liquids purge or flush all gasses and wi
23. ltsmull entsorgt werden darf sondern einem speziellen Sammelsystem zugef hrt werden muss Der Endabnehmer sollte daher den Lieferanten des Ger ts d h die Muttergesellschaft oder den Wiederverk ufer kontaktieren um den Entsorgungsprozess zu starten nachdem er die Verkaufsbedingungen gepr ft hat Special Dual Profibus Gateway User Manual 87 900 115 01 C Special Dual Profibus Gateway User Manual 3 Procedure pour l installation Indications Generales 20 Stockage 21 Preparation pour l installation 21 Installation 21 Utilisation 22 Mise en marche et utilisation du Profibus Gateway 22 Arr t du Profibus Gateway 23 Entretien 23 Mise au rebut 24 Traduction de la mode d emploi originale GE Agilent Technologies 19 52 3 Proc dure pour l installation Indications Generales AVERTISSEMENT ATTENTION 20 52 Cet appareillage a t concu en vue d une utilisation professionnelle Avant toute utilisation de l appareil il est conseill a l utilisateur de lire attentivement cette notice d instructions ainsi que toute autre indication suppl mentaire fournie par Agilent qui d cline par cons quent toute responsabilit en cas de non respect total ou partiel des instructions donn es d utilisation impropre par un personnel non form d op rations non autoris es ou d emploi contraire aux r glementations nationales sp cifiques Les paragraphes suivants fournissent toutes les indications n cessaires
24. ms covering the material in this document that conflict with these terms the warranty terms in the separate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcontract Software is delivered and licensed as Commercial computer software as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will receive no greater than Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Government users will receive no greater than Limited Rights as defined in FAR 52 227 14 June 1987 or DFAR 252 227 7015 b 2 November 1995 as applicable in any technical data Trademarks Windows and MS Windows are U S registered trademarks of Microsoft Corporation Safety Notices A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctl
25. mussen folgende Umgebungsbedingungen ber cksichtigt werden Temperatur von 5 C bis 40 C relative Luftfeuchtigkeit 0 90 ohne Kondensbildung Special Dual Profibus Gateway User Manual 87 900 115 01 C 15 52 2 Anleitung zur Installation VORSICHT Der Profibus Gateway wird in die erste Installationskategorie Uberspannung der Norm EN 61010 1 eingestuft Die Vorrichtung muss an eine Netzlinie angeschlossen werden die dieser Kategorie entspricht Profibus Gateway verf gt au er den f r die serielle Kommunikation vorgesehenen Stecker auch Ausgangs und Eingangsstecker die mit den u eren Schaltungen verbunden werden m ssen sodass kein Teil unter Spannung zug nglich sein kann Sicherstellen dass die Isolierung der mit dem Profibus Gateway verbundenen Vorrichtung auch im Einzelschadenfall so wie von Norm EN 61010 1 vorgesehen eine angebrachte Isolierung besitzt F r die Installation der Options Nebeneinrichtungen beachten Sie bitte den Abschnitt Technical Information Anwendung 16 52 In diesem Absatz werden die wichtigsten Funktionsverfahren angegeben Vor Anwendung des Kontrollers alle elektrische Anschl sse verbinden Anschalten und Betrieb des Profibus Gateway Zum Einschalten des Profibus Gateway braucht dieser nur mit Spannung versorgt zu werden Die rote LED auf der Vorderseite des Gateway zeigt an ob das Ger t versorgt ist Die gr ne LED zeigt hingegen den Status an lang
26. n folgenden Absatzen sind alle notwendigen Informationen ber die Sicherheit des Bedienungspersonals wahrend des Betriebs angegeben Ausf hrliche Angaben sind im Anhang Technical Information enthalten Dieses Handbuch benutzt folgende konventionelle Angaben Die Warnhinweise deuten auf ein Verfahren oder ein besonderes Verhalten hin das bei Nichtbeachtung der Vorsichtsmassnahmen schwere personliche Sch den verursachen k nnte Die Vorsichtshinweise erscheinen vor Verfahren die bei Nichtbeachten Ger teschaden verursachen k nnten Die Hinweise enthalten wichtige Informationen aus dem Text Special Dual Profibus Gateway User Manual 87 900 115 01 C Anleitung zur Installation 2 Lagerung Wahrend des Transportes und der Lagerung des Profibus Gateway durfen folgende Umgebungsbedingungen nicht berschritten werden Temperatur von 0 C bis 70 C relative Luftfeuchtigkeit 0 95 ohne Kondensbildung Vorbereitung fur die Installation Der Profibus Gateway wird in einer speziellen Schutzverpackung geliefert sollten wahrend des Transports Sch den aufgetreten sein verstandigen Sie bitte die lokale Verkaufsabteilung Die Verpackung ordnungsgemafs entsorgen Das Material ist vollstandig recyclebar Installation Den Profibus Gateway nicht in Raumen die Regen Frost Schnee Staub oder aggressivem Gas ausgesetzt sind oder in Raumen mit Explosions oder hoher Brandgefahr verwenden Wahrend der Betatigung
27. nd user is therefore invited to contact the supplier of the device whether the Parent Company or a retailer to initiate the collection and disposal process after checking the contractual terms and conditions of sale 30 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C Special Dual Profibus Gateway User Manual ee 5 Technical Information Introduction 32 Mechanical 32 Installation 33 Profibus Connectors Pin Out 35 Dual Connection Example 36 Rotary Switches 36 Indicators 36 GSD FILE 38 STATE MACHINE 38 Message Mapping 39 Output Buffer Structure for each Controller Connected on tl RS 485 Network 40 Input Buffer Structure for each Controller Connected on the Network 42 Diagnosis Management 45 Technical Specifications 45 Original Instructions Agilent Technologies 31 52 5 Technical Information Introduction The Profibus interface works as a bi directional bridge between the Profibus network and the Agilent RS 485 link The interface provides input data measures and output data commands to the controller In addiction the interface provides standard and user related diagnostics in order to allow the user to manage the exceptions This gateway is classified as DP slave device Mechanical The following outline drawings show the device s dimensions and connections To allow the rack mounting on DIN slide an accessory bracket is provided
28. necessario che siano rispettate le seguenti condizioni ambientali temperatura da 5 C a 40 C umidit relativa 0 90 non condensante Special Dual Profibus Gateway User Manual 87 900 115 01 C 9 52 1 Procedura per l installazione Ia ss Il Profibus Gateway appartiene alla prima categoria di installazione o Uso 10 52 sovratensione prevista dalla normativa EN 61010 1 Connettere quindi il dispositivo ad una linea di alimentazione che soddisfi tale categoria Il Profibus Gateway ha dei connettori per gli ingressi uscite e per la comunicazione seriale che devono essere connessi ai circuiti esterni in modo che nessuna parte sotto tensione sia accessibile Assicurarsi che l isolamento del dispositivo connesso al Profibus Gateway abbia un isolamento adeguato anche in condizione di guasto singolo come previsto dalla normativa EN 61010 1 Per l installazione degli accessori opzionali vedere Technical Information In questo paragrafo sono riportate le principali procedure operative Prima di usare il controller effettuare tutti 1 collegamenti elettrici Accensione ed Uso del Profibus Gateway Per accendere il Profibus Gateway sufficiente fornire la tensione di alimentazione Il LED rosso sul pannello frontale del Gateway indica che il dispositivo alimentato Il LED verde invece indica lo stato del dispositivo Lampeggio lento scambio dati 1 impulso errore link RS 485 ad esempio il dis
29. nstallation Mise au rebut 24 52 Signification du logo WEEE figurant sur les tiquettes Le symbole ci dessous est appliqu conform ment la directive CE nomm e WEEE Ce symbole uniquement valide pour les pays de la Communaut europ enne indique que le produit sur lequel il est appliqu NE doit PAS tre mis au rebut avec les ordures m nag res ou les d chets industriels ordinaires mais passer par un syst me de collecte s lective Apr s avoir v rifi les termes et conditions du contrat de vente l utilisateur final est donc pri de contacter le fournisseur du dispositif maison m re ou revendeur pour mettre en ceuvre le processus de collecte et mise au rebut Special Dual Profibus Gateway User Manual 87 900 115 01 C Special Dual Profibus Gateway User Manual Installation Procedure General Information 26 Storage 2 Preparation for Installation 27 Installation 2 Use 28 Switching on and Use of Profibus Gateway Profibus Gateway Switching off 29 Maintenance 29 Disposal 30 Original Instructions E Agilent Technologies 28 25 52 4 Installation Procedure General Information This equipment is destined for use by professionals The user should read this instruction manual and any other additional information supplied by Agilent before operating the equipment Agilent will not be held responsible for any events occurring due to non compliance even partial with these instruct
30. ological Radioactive List all toxic hazardous materials Include product name chemical name and chemical symbol or formula NOTE If a product is received at Agilent which is contaminated with a toxic or hazardous material that was not disclosed the customer will be held responsible for all costs incurred to ensure the safe handling of the product and is liable for any harm or injury to Agilent employees as well as to any third party occurring as a result of exposure to toxic or hazardous materials present in the product Print Name Authorized Signature Date 5 FAILURE INFORMATION Failure Mode REQUIRED FIELD See next Detailed Description of Malfunction Please provide the error message Application system and model RES Agilent Technologies Vacuum Products Division Request for Return Form Health and Safety Certification Please use these Failure Mode to describe the concern about the product on Page 2 TURBO PUMPS and TURBO CONTROLLERS APPARENT DEFECT MALFUNCTION POSITION Does not start Noise Vertical Does not spin freely Horizontal Upside down Vibrations Does not reach full speed Leak Mechanical Cantact Overtemperature PARAMETERS Power Rotational Speed Current Inlet Pressure Temp 1 Foreline Pressure Temp 2 Purge flow Cooling defective Clogging ION PUMIPS CONTROLLERS Poar vacuum High valtage prablem Bad feedthrough
31. otto sul quale applicato NON deve essere smaltito insieme ai comuni rifiuti domestici o industriali ma deve essere avviato ad un sistema di raccolta differenziata Si invita pertanto l utente finale a contattare il fornitore del dispositivo sia esso la casa madre o un rivenditore per avviare il processo di raccolta e smaltimento dopo opportuna verifica dei termini e condizioni contrattuali di vendita Special Dual Profibus Gateway User Manual 87 900 115 01 C Special Dual Profibus Gateway User Manual 0 e Anleitung zur Installation Allgemeine Informationen 14 Lagerung 15 Vorbereitung fiir die Installation 15 Installation 15 Anwendung 16 Anschalten und Betrieb des Profibus Gateway 16 Abschalten des Profibus Gateway 17 Wartung 17 Entsorgung 18 Ubersetzung der Originalanleitungen e Agilent Technologies 13 52 2 Anleitung zur Installation Allgemeine Informationen VORSICHT 14 52 Diese Vorrichtung ist fur eine professionelle Anwendung bestimmt Der Benutzer muss vor Anwendung vorliegendes Handbuch und alle weitere von Agilent gelieferte Angaben aufmerksam durchlesen Agilent ist fur etwaige auf teilweise oder gesamte Nichtber cksichtigung der Gebrauchsanweisungen beruhende Verantwortungen fur eine nicht geeignete Anwendung durch nicht ausgebildetes Personal fur nicht autorisierte Eingriffe oder fur Anwendung unter Nichtbeachtung der nationalen Bestimmungen nicht verantwortlich In de
32. pe off any excess residue e f ordering an Advance Exchange product please use the packaging from the Advance Exchange to return the defective product e Seal the product in a plastic bag and package product carefully to avoid damage in transit You are responsible for loss or damage in transit e Agilent Technologies is not responsible for returning customer provided packaging or containers e Clearly label package with RA number Using the shipping label provided will ensure the proper address and RA number are on the package Packages shipped to Agilent without a RA clearly written on the outside cannot be accepted and will be returned Return only products for which the RA was issued Product being retumed under a R must be received within 15 business days Ship to the location specified on the printable label which will be sent along with the RA number as soon as we have received all of the required information Customer is responsible for freight charges on returning product Return shipments must camply with all applicable Shipping Regulations IATA DOT etc and carrier requirements RETURN THE COMPLETED REQUEST FOR RETURN FORM TO YOUR NEAREST LOCATION EUROPE NORTH AMERICA PACIFIC RIM Fax 00 39 011 9979 330 Fax Free 00 800 345 345 00 Fax 1 781 860 9252 please visit our website for individual Toll Free 00 800 234 234 00 Toll Free 800 882 7426 Option 3 office information vpt customercare agilent com vpl ra agilent
33. positivo ancora in fase di ricerca controller 2 impulsi errore link Profibus ad esempio il dispositivo non indirizzato dal master Lampeggio veloce errore interno Special Dual Profibus Gateway User Manual 87 900 115 01 C Procedura per l installazione 1 Arresto del Protibus Gateway Per arrestare il Profibus Gateway sufficiente togliere la tensione di alimentazione Manutenzione Il Profibus Gateway non richiede alcuna manutenzione Qualsiasi intervento deve essere eseguito da personale autorizzato Prima di effettuare qualsiasi intervento sul sistema scollegarlo dall alimentazione Prima di rispedire al costruttore il Profibus Gateway per riparazioni o advanced exchange service indispensabile compilare e far pervenire al locale ufficio vendite la scheda Sicurezza e Salute allegata al presente manuale di istruzioni Copia della stessa deve essere inserita nell imballo del sistema prima della spedizione Qualora il Profibus Gateway dovesse essere rottamato procedere alla sua eliminazione nel rispetto delle normative nazionali specifiche Special Dual Profibus Gateway User Manual 87 900 115 01 C 11 52 1 Procedura per l installazione Smaltimento 12 52 Significato del logo WEEE presente sulle etichette Il simbolo qui sotto riportato applicato in ottemperanza alla direttiva CE denominata WEEE Questo simbolo valido solo per i paesi della Comunit Europea indica che il prod
34. r la tension d alimentation Le voyant rouge sur le panneau frontal du Gateway indique que le dispositif est aliment Le voyant vert par contre indique la condition du dispositif Clignotement lent change donn es 1impulsion erreur lien RS 485 par exemple le dispositif est encore en phase de recherche contr leur 2 impulsions erreur lien Profibus par exemple le dispositif n est pas adress par le master maitre Clignotement rapide erreur interne Special Dual Profibus Gateway User Manual 87 900 115 01 C Proc dure pour l installation 3 Arr t du Profibus Gateway Entretien Pour arr ter le Profibus Gateway il suffit de retirer la tension d alimentation Le contr leur arr te imm diatement la pompe Le Profibus Gateway n exige aucun entretien particulier Toute intervention doit tre effectu e par un personnel agr Avant de renvoyer le Profibus Gateway au constructeur pour r paration ou Advanced exchange service remplir et faire parvenir au bureau Agilent de votre r gion la fiche S curit et Sant jointe au pr sent manuel d instructions Une copie de cette fiche devra tre mise dans l emballage de la pompe avant l exp dition En cas de mise au rebut du Profibus Gateway proc der son limination conform ment aux r glementations nationales concernant la gestion des d chets Special Dual Profibus Gateway User Manual 87 900 115 01 C 23 52 3 Proc dure pour l i
35. rd the purchase of new or refurbished Products are subject to prior Agilent approval and may incur a restocking fee Please reference the original purchase order number e Units returned for evaluation will be evaluated and a quote for repair will be issued If you choose to have the unit repaired the cost of the evaluation will be deducted from the final repair pricing A Purchase Order for the final repair price should be issued within 3 weeks of quotation date Units without a Purchase Order for repair will be returned to the customer and the evaluation fee will be invoiced e A Special Cleaning fee will apply to all exposed products per Section 4 of this document e f requesting a calibration service units must be functionally capable of being calibrated Pg 3 3 United States Agilent Technologies Vacuum Products Division 121 Hartwell Avenue Lexington MA 02421 USA Tel 1 781 861 7200 Fax 1 781 860 5437 Toll Free 1 800 882 7426 Benelux Agilent Technologies Netherlands B V Vacuum Products Division Herculesweg 8 4338 PL Middelburg The Netherlands Tel 31 118 671570 Fax 31 118 671569 Toll Free 00 800 234 234 00 Canada Central coordination through Agilent Technologies Vacuum Products Division 121 Hartwell Avenue Lexington MA 02421 USA Tel 1 781 861 7200 Fax 1 781 860 5437 Toll Free 1 800 882 7426 China Agilent Technologies China Co Ltd Vacuum Products Division No 3 Wang Jing Bei
36. sames Blinken Datenaustausch Impuls RS 485 Verbindungsfehler z B das Ger t sucht noch die Steuereinheit 2 Impulse Profibus Verbindungsfehler z B das Ger t wird nicht vom Master adressiert schnelles Blinken interner Fehler Special Dual Profibus Gateway User Manual 87 900 115 01 C Anleitung zur Installation 2 Abschalten des Profibus Gateway Um den Profibus Gateway abzuschalten genugt es die elektrische Versorgung abzuschalten Wartung Fur den Profibus Gateway ist keine Wartung erforderlich Jeder Eingriff unterliegt autorisiertem Personal Vor jedem Eingriff die elektrische Versorgung unterbrechen Vor R cksendung des Profibus Gateway zum Hersteller zu Reparatur oder Advanced Exchange Service muss das Formular Sicherheit und Gesundheit das diesem Handbuch beigelegt ist ausgef llt und an das lokale Verkaufsb ro gesendet werden Eine Kopie davon muss der Systemverpackung beigef gt werden Im Falle einer Verschrottung des Profibus Gateway muss diese nach den nationalen Vorschriften erfolgen Special Dual Profibus Gateway User Manual 87 900 115 01 C 17 52 2 Anleitung zur Installation Entsorgung 18 52 Bedeutung des WEEE Logos auf den Etiketten Das folgende Symbol ist in Ubereinstimmung mit der EU Richtlinie WEEE Waste Electrical and Electronic Equipment angebracht Dieses Symbol nur in den EU Landern gultig zeigt an dass das betreffende Produkt nicht zusammen mit Hausha
37. t install or use the Profibus Gateway in an environment exposed to atmospheric agents rain snow ice dust aggressive gases or in explosive environments or those with a high fire risk During operation the following environmental conditions must be respected temperature from 5 C to 40 C relative humidity 0 90 non condensing Special Dual Profibus Gateway User Manual 87 900 115 01 C 27 52 4 Installation Procedure CAUTION The Profibus Gateway belongs to the first installation or overvoltage category Use 28 52 as per directive EN 61010 1 Connect the device to a mains line that satisfy the above category The Profibus Gateway has Input Output and serial communication connectors that must be connected to external circuits in such a way that no electrical part is accessible Be sure that the insulation of the device connected to the Profibus Gateway is adequate even in the case of single fault as per directive EN 61010 1 For installation of optional accessories see Technical Information This paragraph details the fundamental operating procedures Make all electrical connections before the use of the system Switching on and Use of Profibus Gateway To switch on the Profibus Gateway it is necessary to supply the mains The red led on the Gateway front panel indicates the device is powered The green led indicates the device status Blink slow data exchange pulse RS 48
38. y performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met Special Dual Profibus Gateway User Manual 87 900 115 01 C Special Dual Profibus Gateway Special Dual Profibus Gateway Special Dual Profibus Gateway User Manual 87 900 115 01 C 3 52 Special Dual Profibus Gateway 4 52 Special Dual Profibus Gateway User Manual 87 900 115 01 C Contents Contents 1 Procedura per l installazione 7 Informazioni Generali 8 Immagazzinamento 9 Preparazione per l installazione 9 Installazione 9 Uso 10 Manutenzione 11 Smaltimento 12 2 Anleitung zur Installation 13 Allgemeine Informationen 14 Lagerung 15 Vorbereitung f r die Installation 15 Installation 15 Anwendung 16 Wartung 17 Entsorgung 18 3 Proc dure pour l installation 19 Indications Generales 20 Stockage 21 Special Dual Profibus Gateway User Manual 87 900 115 01 C 5 52 Contents 6 52 5 Preparation pour l installation 21 Installation 21 Utilisation 22 Entretien 23 Mise aurebut 24 Installation Procedure 25 Gener