Home

2 HP Totally Enclosed Fan Cooled Electric Motor

image

Contents

1. Properly assess the resultant side load before installing your motor If your side load exceeds the value 79 1 Ibs please contact Princess Auto to explore options for use of roller bearings The allowable loads are calculated to result in a minimum of 40 000 hours of bearing life under normal conditions If the application calls for significant thrust loads linear loads please contact Princess Auto to determine if you have the correct motor for your application MAINTENANCE Maintain the device with care A device in good condition is efficient easier to control and will have fewer problems Inspect the device components periodically Repair or replace damaged or worn components 3 Inspect the device fittings alignment and hoses and power supply cord periodically Have damaged or worn components repaired or replaced by an authorized technician 4 Maintain the device s label and name plate These carry important information If unreadable or missing contact Princess Auto Ltd for replacements nN WARNING Only qualified service personnel should repair the device An improperly repaired device may present a hazard to the user and or others CONDENSATE DRAINS The motor comes with one way sintered brass breather drains These drains allow the motor to expel liquids from the casing without allowing liquid to enter the motor The drains may require periodic maintenance to keep them clean of debris and flowing freely Occasion
2. 1 Commencez en vous assurant que tous les contacts sont propres et bien serr s V rifiez s il y a des dommages vidents 2 V rifiez chaque partie du circuit afin de d terminer s il y a du courant jusqu ce que vous ayez d tect le probl me 3 Demandez un technicien de service qualifi de r parer ou de remplacer le circuit L arbre moteur ne tourne pas lorsqu on applique le courant D branchez le moteur de la charge et essayez le sans charge Si l arbre ne tourne pas cela signifie que le roulement est immobilis Demandez un technicien qualifi de r parer ou de remplacer le moteur Visitez www princessauto com pour plus d informations 11 V 3 02 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur 8472888 Probl me s Le moteur produit un choc lectrique Cause s possible s Fil de mise la masse bris ou d branch Solution s propos e s Rebranchez ou remplacez le fil de masse et v rifiez si la mise la masse est efficace Un conducteur sous tension est branch au cadre du moteur Demandez un technicien qualifi d inspecter le moteur et de r parer ou remplacer le c blage d fectueux Surcharge du moteur en cours de fonctionnement 1 Il est possible qu une pi ce mobile du moteur soit gripp e Inspectez le moteur afin de v rifier si des pi ces sont en contact V rifiez si l arbre du moteur est dr
3. tre align s avec pr cision alors que l arbre devrait tourner librement sans grippage ou r sistance Les moteurs de Princess Auto avec un cadre de type 254T ou plus gros sont exp di s avec un verrou de roulement c t moteur oppos Si des verrous de roulement c t avant sont souhait s veuillez demander l aide de Princess Auto Fabrication d un protecteur AVERTISSEMENT Les protecteurs doivent tre install s afin de cr er un p rim tre s curitaire et prot g et autour des pi ces rotatives comme les raccords les poulies les ventilateurs externes et les rallonges d arbre inutilis es Apr s avoir compl t l installation du moteur un protecteur de dimensions appropri es doit tre construit et install autour du moteur Ce protecteur doit emp cher le personnel de venir en contact avec toute pi ce mobile du moteur ou du syst me d entra nement mais en permettant qu une quantit suffisante d air de refroidissement circule au dessus du moteur Si un frein sur moteur est install pr voyez des protections appropri es pour le personnel en cas de bris du frein Toutes les pi ces doivent tre prot g es en permanence afin de pr venir tout contact accidentel par le personnel Un contact accidentel avec des parties du corps ou les v tements peut entra ner des blessures graves ou mortelles Si on a install ce moteur conform ment ces instructions il est conforme la directive en mati re de machinerie
4. de l EEC Les exigences de compatibilit lectromagn tique en ce qui concerne la conformit au CE sont respect es lorsque le courant d entr e est purement sinusoidal INSTALLATION DU SYST ME LECTRIQUE Mise la masse du moteur Placez le moteur la masse de la fa on d crite dans le CE et dans les codes locaux Consultez le Code canadien de l lectricit CE en ce qui concerne la mise la masse des moteurs et des g n ratrices et pour obtenir des renseignements sur la mise la masse Au moment de proc der au branchement la masse l installateur devrait s assurer qu il existe un raccordement de m tal solide et permanent entre le point de mise la masse le moteur ou le bo tier des bornes de la g n ratrice ainsi que le cadre du moteur ou de la g n ratrice Visitez www princessauto com pour plus d informations 7 V 3 02 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur 8472888 CABLAGE DE VOTRE MOTEUR AVERTISSEMENT Ne touchez pas les connexions lectriques avant de vous tre assur que le courant est d branch Reportez vous Norme OSHA 1910 147 intitul e Contr le de l nergie dangereuse verrouillage tiquetage AVERTISSEMENT Les temp ratures la surface des enceintes du moteur peuvent augmenter un point tel qu il en r sultera un inconfort ou des blessures pour les employ s qui viendraient en contact avec ces surfaces L utilisateur devrait assurer une prote
5. pas utilis Prot gez vous contre les chocs lectriques lorsque vous travaillez en pr sence d quipement lectrique vitez le contact entre votre corps et les surfaces reli es la terre comme les tuyaux radiateurs cuisini res et r frig rateurs Il y a un risque plus lev de choc lectrique si votre corps est mis la terre Ne modifiez aucune partie de l outil ou des accessoires Toutes les pi ces et tous les accessoires sont con us avec des dispositifs de s curit int gr s qui seront compromis s ils sont modifi s Assurez vous que la source d nergie est conforme aux exigences de votre quipement Au moment de c bler un appareil lectrique respectez tous les codes en mati re d lectricit et de s curit ainsi que les versions les plus r centes du Code canadien de l lectricit CE et du code du Centre canadien d hygi ne et de s curit au travail CCHST V 3 02 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur 8472888 ENDROITS DANGEREUX AVERTISSEMENT Ce moteur lectrique convient aux emplacements de la division 2 Ne placez pas dans un endroit dangereux o l on doit faire appel un moteur de la division 1 Assurez vous que le moteur install convient l emplacement dans lequel il sera utilis Apprenez conna tre les puissances nominales et les d tails particuliers en ce qui concerne l environnement d utilisation des moteurs e Un emplacement de la divis
6. Grounding the Motor Ground the motor according to CE and local codes Consult the Canadian Electrical Code CE for information on grounding of motors and generators and general information on grounding In making the ground connection the installer should make certain that there is a solid and permanent metallic connection between the ground point the motor or generator terminal housing and the motor or generator frame WIRING YOUR MOTOR WARNING Do not touch electrical connections unless you first ensure that power has been disconnected Please refer to OSHA standard 1910 147 titled The Control of Hazardous energy lockout tag out WARNING Surface temperatures of motor enclosures may reach temperatures that can cause discomfort or injury to personnel coming in contact with hot surfaces Protection should be provided by the user to protect against accidental contact with hot surfaces Failure to observe this precaution could result in bodily injury Connect the motor as shown in the connection diagram on the motor nameplate Be sure to identify the proper wiring diagram for the motor you are installing If you have difficulty determining the proper wiring diagram for your motor please contact Princess Auto for assistance If this motor is installed as part of a motor control drive system connect and protect the motor according to the control manufacturer s diagram When using AC motors with frequency inverters be certain that the moto
7. NGER Only qualified personnel trained in the safe installation and operation of this equipment should install this motor When improperly installed or used rotating equipment can cause serious or fatal injury 1 Before you install operate or perform maintenance become familiar with the following e NEMA Publication MG 2 Safety Standard for Construction and Guide for Selection Installation and Use of Electric Motors e EC 60072 1 Electrical and IEC72 1 Mechanical specifications ANSI C51 5 e The Canadian Electrical Code CE and local codes and practices e OSHA standard 1910 147 titled The Control of Hazardous energy lockout tag out 2 Connect Power and Ground to the motor according to the Canadian Electrical Code CE or IEC and local codes 3 Provide a permanent guard to prevent accidental contact of body parts or clothing with rotating or moving parts of motor Beware of burns if motor is hot 4 Shaft key must be secured before starting motor 5 Mounting bolts should be high tensile steel Be sure to use a Suitable locking device on each bolt spring washer or thread lock compound 6 Do not apply power to the motor until the motor is securely mounted by its mounting holes 7 This motor must only be connected to the proper line voltage line frequency and load size 8 Motors are not to be used for load holding or restraining unless a properly sized brake is installed If a motor mounted brake is installed provide proper safeguards i
8. V 3 02 8472888 POWER 2 HP Totally Enclosed Fan Cooled Electric Motor User Manual Please read and understand all instructions before use Retain this manual for future reference V 3 02 2 HP Totally Enclosed Fan Cooled Electric Motor 8472888 SPECIFICATIONS Motor Horsepower 2 HP Service Factor 1 15 Motor Phase 1 Full Load Speed 1 730 RPM Motor Type C Face Frame Type 56HC Insulation Type Class F Overload Protection Manual Only Hazardous Location Use Division 2 Shaft Diameter 5 8 in Rotation Direction Reversible Voltage Single Phase 115V 208 230V Frequency 60 Hz Full Load Amperage Single Phase 18 4A 10 1A to 9 2A Torque Full Load 6 1 ft lb Starting 19 58 17 66 ft lb Housing Enclosed Yes Drip Proof No Base Rigid Yes Resilient No For technical questions call 1 800 665 8685 8472888 2 HP Totally Enclosed Fan Cooled Electric Motor V 3 02 INTRODUCTION This fan cooled motor is perfect for demanding environments and applications requiring a high Starting torque FUNCTIONS Totally enclosed design makes it ideal for dirty moist or mildly corrosive operating conditions The Division 2 motor is suitable for environments where explosive vapours or particulates are uncommon The compressor has a high starting torque approx 300 of full load torque for applications such as pumps conveyors compressors augers etc It has dual capacitors for a
9. a t con u IDENTIFICATION DES PI CES AVERTISSEMENT Ne faites pas fonctionner l outil si des pi ces sont manquantes Remplacez les pi ces manquantes avant l utilisation Le non respect de cet avertissement peut entra ner une d fectuosit et des blessures graves Retirez les pi ces et les accessoires de l emballage et v rifiez s il y a des dommages Assurez vous que tous les articles sur la liste de pi ces sont compris Contenu e Moteur lectrique 6 En cas de questions techniques appelez le 1 800 665 8685 8472888 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur V 3 02 ASSEMBLY INSTALLATION Montage Mont sur pied Les moteurs mont s sur devraient tre plac s sur une fondation solide afin de pr venir une vibration excessive Il est possible d utiliser des cales si l emplacement est in gal Mont sur collerette Les moteurs mont s sur collerette doivent tre correctement appuy s et align s Si un sens de rotation inad quat est nuisible la charge v rifiez la rotation ou butez le moteur avant de raccorder la charge l arbre moteur Entra nement par courroie en V Placez la poulie pr s du bo tier du moteur Pr voyez un jeu afin de permettre le mouvement lat ral de l arbre moteur Evitez de trop serrer les courroies puisqu il pourrait en r sulter un bris pr matur des roulements ou de l arbre Couplage direct Les moteurs couplage direct doivent
10. ally remove the brass drains and wash them thoroughly Eliminate any built up debris that may be impeding their operation For motors that are equipped with rubber plugs in their condensate drain holes be sure to remove the plug especially if the motor is installed in a location where condensate build up is likely In all instances ensure that the drain is in the lowest portion of the motor Some motors may require rotation of the end plates e g if the mounting location is not a typical horizontal mounting LUBRICATION The bearings are permanently lubricated and do not require additional grease 8 For technical questions call 1 800 665 8685 8472888 2 HP Totally Enclosed Fan Cooled Electric Motor TROUBLESHOOTING Contact Princess Auto Ltd for a solution if the device does not function properly or parts are missing If unable to do so have a qualified technician service the device V 3 02 Problem s Motor will not start Possible Cause s There is a blown fuse or open circuit breaker Suggested Solution s Test for voltage at the fuse or circuit breaker Also see if the voltage amp rating of the fuse or circuit breaker is correct for the motor It should exceed the Motor s FLC by 25 percent Motor starter overload activated Let cool and then reset overloads Test the starter before starting motor again The thermal switch is open Reset the thermal switch but beware as the motor may autom
11. atically start when reset Low or no voltage reaching motor Check each motor terminal s voltage The voltage should be within 10 of the voltage on the motor s nameplate Disconnect the load and apply power to the motor If the motor operates normally then the issue is with the load attached to the motor Should the motor still not work have it serviced or replaced by a qualified technician Power enters control circuit but does not reach the motor 1 Begin by confirming all contacts are clean and tight Examine for obvious damage 2 Test each part of the circuit for power until the problem area is discovered 3 Have a qualified service technician repair or replace the circuit Fuse circuit breaker overloads There is a blown fuse or open circuit breaker Test for voltage at the fuse or circuit breaker Also see if the voltage amp rating of the fuse or circuit breaker is correct for the motor It should exceed the Motor s FLC by 25 percent Motor starter overload activated Let cool and then reset overloads Test the starter before starting motor again Low or no voltage reaching motor Check each motor terminal s voltage The voltage should be within 10 of the voltage on the motor s nameplate Disconnect the load and apply power to the motor If the motor operates normally then the issue is with the load attached to the motor Should the motor still not work have it se
12. cessive under load but normal when there is no load Inspect the load to determine the problem 5 If the no load current is above the listed rating have the motor serviced or replaced by a qualified technician Starting windings remain Switch motor off to listen for a click active in circuit as This is the centrifugal switch closing as the motor accelerates motor slows 10 For technical questions call 1 800 665 8685 8472888 2 HP Totally Enclosed Fan Cooled Electric Motor V 3 02 Problem s Motor produces electric shock Possible Cause s Worn or poorly lubricated bearings Suggested Solution s Damaged or poorly lubricated bearing can be heard This may be a result of wear inadequate oil reaching the bearings or the motor overheating Contact Princess Auto Ltd for a solution Inadequate ventilation reaching the motor Clean clear all ventilation openings Use dry compressed air if blowing debris out of the ventilation openings Excessive vibration or noise Excessive end play in motor 1 An unbalanced motor or load creates vibration Check for excessive end play or loose parts 2 Realign the motor and load Check end play by trying to move the motor shaft in and out Add end play washers as required 3 If the shaft is bent replace the rotor or motor Worn or poorly lubricated bearings Damaged or poorly lubricated bearing can be heard This may be a r
13. ction afin d emp cher tout contact accidentel avec les surfaces chaudes d faut de respecter cette pr caution il pourrait en r sulter des blessures corporelles Branchez le moteur de la fa on indiqu e sur le sch ma de branchement qui appara t sur la plaque signal tique du moteur Assurez vous d identifier le sch ma de c blage appropri qui correspond au moteur que vous installez Si vous avez de la difficult d terminer le sch ma de c blage qui correspond votre moteur communiquez avec Princess Auto pour obtenir de l aide Si ce moteur est install dans le cadre du syst me d entra nement de commande du moteur branchez et prot gez le moteur de la fa on d crite sur le sch ma du fabricant de commande Lorsque vous utilisez des moteurs c a avec des inverseurs de fr quence assurez vous de ne pas d passer la vitesse nominale maximale Le c blage les fusibles et la mise la masse doivent tre conformes au Code canadien de l lectricit CE aux exigences de la Commission lectrotechnique internationale CEI et aux codes locaux Si un sens de rotation inad quat est nuisible la charge v rifiez la rotation ou butez le moteur avant de raccorder Tension Haute la charge l arbre moteur Lorsqu on d marre un moteur Basse Tension raccord la charge celui ci devrait d marrer rapidement et fonctionner de mani re r guli re Sinon arr tez P1 Conduite1 P1 Conduite imm diatement le moteur
14. cul que les charges permises permettent une dur e de vie des roulements d au moins 40 000 heures dans des conditions normales Si l application fait appel des charges de pouss e consid rables charges lin aires communiquez avec Princess Auto afin de d terminer si vous utilisez le type de moteur qui convient votre utilisation ENTRETIEN 1 Entretenez l outil avec soin Un outil en bon tat sera efficace plus facile contr ler et pr viendra les probl mes de fonctionnement 2 Inspectez les composants de l outil r guli rement R parez ou remplacez les composants endommag s ou us s 3 Inspectez les fixations de l appareil l alignement les tuyaux et le cordon d alimentation p riodiquement Demandez un technicien autoris de r parer ou de remplacer les composants endommag s ou us s 4 Veillez ce que l tiquette et la plaque signal tique demeurent intactes sur l outil Elles comportent des renseignements importants Si elles sont illisibles ou manquantes communiquez avec Princess Auto Ltd pour les remplacer AVERTISSEMENT Seul un personnel d entretien qualifi doit effectuer la r paration de l appareil Un appareil mal r par peut pr senter un risque pour l utilisateur et ou pour les autres DRAINS DE CONDENSAT Le moteur est muni de drains avec reniflard de laiton fritt unidirectionnel Ces drains permettent au moteur d expulser les liquides du carter sans permettre a ceux ci d entr
15. d acier haute r sistance Assurez vous d utiliser un dispositif de verrouillage appropri sur chaque boulon rondelle ressort ou compos de blocage pour filets N appliquez le courant au moteur qu apr s que celui ci est retenu solidement dans ses orifices de montage Ce moteur doit tre reli uniquement la tension de ligne la fr quence de ligne et une charge ad quates N utilisez pas les moteurs pour retenir des charges moins qu un frein de taille appropri e ne soit install Si un frein sur moteur est install pr voyez des protections appropri es en cas de bris du frein D branchez toutes les sources d alimentation arr tez le moteur et laissez le refroidir avant de proc der son entretien Dans le cas des moteurs monophas s d chargez les condensateurs de d marrage et ou de marche avant de proc der l entretien Ne contournez pas et ne neutralisez pas les dispositifs de s curit CONSIGNES DE S CURIT G N RALES S curit en lectricit AVERTISSEMENT Tout le c blage doit tre install par un lectricien qualifi AVERTISSEMENT Pour r duire les risques de choc lectrique assurez vous que la fiche est branch dans une prise de courant correctement mise la masse 1 2 Visitez www princessauto com pour plus d informations D connectez l outil de la source d nergie avant le nettoyage l entretien le remplacement de pi ces ou d accessoires ou lorsqu il n est
16. er dans le moteur Les drains peuvent devoir faire l objet d un entretien p riodique afin qu ils soient exempts de d bris et pour assurer une circulation libre Retirez l occasion les drains en laiton et lavez les parfaitement Eliminez toute accumulation de d bris pouvant emp cher leur fonctionnement Dans le cas des moteurs munis d obturateurs de caoutchouc dans les orifices de vidange de condensat assurez vous d enlever l obturateur en particulier si le moteur est install dans un endroit o accumulation de condensat est probable Dans tous les cas assurez vous que le drain se trouve dans la partie la plus basse du moteur Sur certains moteurs il se peut qu on doive tourner les plaques d extr mit p ex si le lieu d installation ne permet pas une installation normale l horizontale LUBRICATION Les roulements sont lubrifi s en permanence et ne demandent pas de graisse additionnelle Visitez www princessauto com pour plus d informations 9 V 3 02 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur Si l outil ne fonctionne pas correctement ou si des pi ces sont manquantes veuillez contacter Princess Auto Ltd afin de trouver une solution Si ce n est pas possible demandez un technicien qualifi de r parer l outil 8472888 Probl me s Le moteur ne d marre pas Cause s possible s Un fusible est saut ou un disjoncteur est ouvert Solution
17. esult of wear inadequate oil reaching the bearings or the motor overheating Contact Princess Auto Ltd for a solution Visit www princessauto com for more information V 3 02 8472888 tie t f G f idi Manuel d utilisateur Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard V 3 02 EX Moteur lectrique de 2 CU SPECIFICATIONS tie t f idi Moteur Puissance 2 CV Facteur de service MS Phase du moteur 1 Vitesse avec pleine charge 1 730 tr min Type de moteur Face en C Type de cadre 56HC Type d isolant Cat gorie F Protection contre les surcharges Manuel seulement Utilisation pour endroits dangereux Division 2 Arbre Diam tre 5 8 po Sens de rotation R versible Tension Monophas 115 208 230 V Fr quence 60 Hz Intensit Monophas 18 4 10 1 9 2 A charge maximale Couple Charge maximale 6 1 pi lb D marrage 19 58 17 66 pi lb Boitier Renferm Oui Abrit Non Base Rigide Oui R silient Non En cas de questions techniques appelez le 1 800 665 8685 8472888 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur V 3 02 INTRODUCTION Ce moteur refroidi par ventilateur convient id alement aux applications et aux environnements exigeants qui n cessitent un couple de d marrage lev FUNCTIONS Concept enti rement
18. et d terminez la cause Voici les causes possibles Faible tension au niveau du moteur P2 raccords inad quats au niveau du moteur ou charge trop lev e V rifiez le courant du moteur apr s T3 Bande quelques minutes de fonctionnement et comparez T8 f le courant mesur celui indiqu sur la plaque signal tique T2 Lorsque le moteur est la position F1 les conducteurs g identifi s TOP dessus sortent du carter en passant T4 Conduite Bande au dessus de l axe central du moteur tandis que ceux T5 En identifi s BOTTOM dessous sortent du carter en passant T4 Conduite 2 au dessous de l axe central Servez vous de cette consigne pour rep rer les conducteurs manquants ou mal tiquet s Pour inverser une tension interchangez les fils T5 amp T8 8 En cas de questions techniques appelez le 1 800 665 8685 8472888 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur V 3 02 Chargement lat ral maximal Lorsqu une application demande une charge lat rale consid rable charge radiale du moteur l application peut faire appel des roulements rouleaux pour viter de r duire la dur e de vie du moteur valuez correctement la charge lat rale qui en r sulte avant d installer votre moteur Si votre charge lat rale exc de la valeur indiqu e 35 88 kg communiquez avec Princess Auto afin d tudier les options en mati re d utilisation des roulements rouleaux On a cal
19. fast startup and smooth efficient running The compressor includes manual overload protection and oversized ball bearings for safety and longevity The C Face flange allows for easy mounting of close coupled pumps speed reducers brackets etc SAFETY WARNING Read and understand all instructions before using this device The operator must follow basic precautions to reduce the risk of personal injury and or damage to the equipment Keep this manual for safety warnings precautions operating or inspection and maintenance instructions HAZARD DEFINITIONS Please familiarize yourself with the hazard notices found in this manual A notice is an alert that there is a possibility of property damage injury or death if certain instructions are not followed DANGER This notice indicates an immediate and specific hazard that will result in severe personal injury or death if the proper precautions are not taken WARNING This notice indicates a specific hazard or unsafe practice that could result in severe personal injury or death if the proper precautions are not taken CAUTION This notice indicates a potentially hazardous situation that may result in minor or moderate injury if proper practices are not taken NOTICE This notice indicates that a specific hazard or unsafe practice will result in equipment or property damage but not personal injury WORK AREA 1 Operate in a safe work environment Keep your work area clean well lit and f
20. ferm de telle sorte qu il est id al pour les environnements poussi reux humides ou l g rement corrosifs Le moteur de la division 2 convient aux environnements o des vapeurs et des particules explosives sont peu fr quentes Le compresseur a un d marrage couple lev environ 300 du couple charge maximale par exemple pour les pompes les convoyeurs les compresseurs les tari res etc Il comprend deux condensateurs afin d assurer un d marrage rapide et un fonctionnement r gulier et efficace Le compresseur comprend une protection manuelle contre les surcharges et roulements billes surdimensionn s qui sont plus solides et plus durables La collerette avec face en C permet de faciliter le montage des pompes accoupl es en position rapproch e les r ducteurs de vitesse les supports etc S CURIT AVERTISSEMENT Veuillez lire et comprendre toutes les instructions avant d utiliser cet outil L utilisateur doit respecter les pr cautions de base lorsqu il utilise cet outil afin de r duire le risque de blessure ou de dommage l quipement Conservez ce manuel qui contient les avertissements de s curit les pr cautions les instructions de fonctionnement ou d inspection et d entretien D FINITIONS DE DANGER Veuillez vous familiariser avec les avis de danger qui sont pr sent s dans ce manuel Un avis est une alerte indiquant qu il existe un risque de dommage la propri t de blessure ou de d c
21. ion 1 comporte une substance inflammable pr sente de mani re continue ou intermittente dans l air lors des op rations normales ou le moteur peut tre expos la substance en raison de travaux de r paration et d entretien fr quents e Un emplacement de la division 2 concerne la pr sence d une substance inflammable dans un syst me ferm ou remis dans un conteneur alors que l exposition peut se produire dans des conditions anormales tels un d versement du conteneur ou un bris d quipement CATEGORIE gaz manations Groupe A Ac tyl ne Groupe B Butadi ne oxyde d thyl ne hydrog ne oxyde de propyl ne Groupe C Ac tald hyde cyclopropane di thyl ther thyl ne isopr ne Groupe D Ac tone acrylonitrile ammonium benz ne butane thyl ne dichlorure essence hexane m thane m thanol naphte propane propyl ne styr ne tolu ne ac tate de vinyle chlorure de vinyle xyl me CAT GORIE II poussi res combustibles Groupe E Aluminium magn sium et poussi res d autres m taux pr sentant des caract ristiques comparables Groupe F Noir de carbone coke ou poussi re de charbon Groupe G Farine amidon ou poussi re de grain UTILISATION ET ENTRETIEN DE L APPAREIL Utilisez le bon outil pour la t che effectuer Cet outil a t con u pour une utilisation sp cifique vitez de modifier ou d alt rer cet outil ou de l utiliser une fin autre que celle pour laquelle il
22. liquides inflammables S CURIT PERSONNELLE ATTENTION Portez de l quipement de protection personnelle homologu par l Association canadienne de normalisation CSA ou l American National Standards Institute ANSI quipement de protection personnelle Portez toujours des lunettes antiprojections qui offrent une protection frontale et lat rale pour les yeux 2 Portez des gants qui prot gent en fonction des mat riaux de travail et pour r duire les effets des vibrations de l outil 3 Les chaussures antid rapantes sont recommand es pour maintenir la stabilit et l quilibre au sein de l environnement de travail 4 Portez des v tements de protection con us pour l environnement de travail et pour l outil Pr cautions personnelles Gardez le contr le de l outil de vos mouvements et de l environnement de travail pour viter les blessures ou le bris de l outil 1 N utilisez pas l outil si vous tes fatigu ou sous l effet de drogues d alcool ou de m dicaments 2 vitez de porter des v tements ou des bijoux pouvant se prendre dans les pi ces mobiles d un outil Gardez les cheveux longs recouverts ou attach s 3 N utilisez pas l outil si vous devez tirer les bras pour vous en servir Une stabilit et un quilibre appropri s sont n cessaires afin d avoir un meilleur contr le en cas de situations inattendues CONSIGNES DE S CURIT SP CIFIQUES DANGER Seul le personnel comp tent et ayant sui
23. n case of brake failure 9 Disconnect all power services stop the motor and allow it to cool before servicing 10 For single phase motors discharge the start and or run capacitors before servicing 11 Do not by pass or disable any safety devices 4 For technical questions call 1 800 665 8685 8472888 2 HP Totally Enclosed Fan Cooled Electric Motor V 3 02 GENERAL SAFETY PRECAUTIONS Electrical Safety WARNING All wiring should be performed by a qualified electrician WARNING To reduce risk of electric shock be certain that the plug is connected to a properly grounded receptacle 1 Disconnect device from power source before cleaning servicing changing parts accessories or when not in use 2 Protect yourself against electric shocks when working on electrical equipment Avoid body contact with grounded surfaces such as pipes radiators cooking stoves and refrigerators There is an increased chance of electrical shock if your body is grounded 3 Do not alter any parts of the device or accessories All parts and accessories are designed with built in safety features that may be compromised if altered 4 Make certain that power source conforms to requirements of your equipment 5 When wiring an electrically driven device follow all electrical and safety codes as well as the most recent Canadian Electrical Code CE and Canadian Centre for Occupational Health and Safety CCOHS HAZARDOUS LOCATIONS WARNING This electric mot
24. oit 2 Faites fonctionner le moteur sous une charge normale et v rifiez la quantit de courant consomm 3 D branchez le moteur de sa charge et v rifiez le courant consomm lorsqu il fonctionne sans charge 4 Sila consommation de courant est excessive sous charge mais normale lorsqu il n y a aucune charge v rifiez la charge afin de d terminer le probl me 5 Demandez un technicien qualifi de r parer ou de remplacer le moteur si le courant sans charge exc de le courant nominal indiqu Les enroulements de d marrage demeurent actifs dans le circuit alors que le moteur acc l re Arr tez le moteur pour couter s il fait entendre un d clic Le commutateur centrifuge se ferme alors que le moteur ralentit Roulements us s ou mal lubrifi s Ventilation inad quate au niveau du moteur Un roulement endommag ou mal lubrifi fait entendre un bruit Cela peut tre attribuable l usure une quantit insuffisante d huile au niveau des roulements ou une surchauffe du moteur Communiquez avec Princess Auto Ltd pour rem dier au probl me Nettoyez d gagez tous les orifices de ventilation Utilisez de l air comprim pour expulser les d bris par les orifices de ventilation En cas de questions techniques appelez le 1 800 665 8685 12 8472888 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur V 3 02 Probl me s Cause s possible s Solution
25. or is suitable for Division 2 locations Do not place in a hazardous location requiring a Division 1 motor Ensure that the motor installed is proper for the location in which it will operate Familiarize yourself with the ratings and the specific details of the motors working environment e A Division 1 location has an ignitable substance present in the air continuously or intermittently during normal operations or the motor may be exposed to the substance due to frequent repair and maintenance work e A Division 2 location is where an ignitable substance is in a closed system or stored in a container but exposure can result under abnormal conditions such as a container spill or equipment failure CLASS I Gases Vapors Group A Acetylene Group B Butadiene ethylene oxide hydrogen propylene oxide Group C Acetaldehyde cyclopropane diethel ether ethylene isoprene Group D Acetone acrylonitrite ammonia benzene butane ethylene dichloride gasoline hexane methane methanol naphtha propane propylene styrene toluene vinyl acetate vinyl chloride xylem CLASS II Combustible Dusts Group E Aluminum magnesium and other metal dusts with similar characteristics Group F Carbon black coke or coal dust Group G Flour starch or grain dust Visit www princessauto com for more information 5 V 3 02 2 HP Totally Enclosed Fan Cooled Electric Motor 8472888 USE AND CARE OF THE DEVICE Use the correct device for the job Thi
26. re bearing failure or shaft breakage Direct coupled Direct coupled motors should be carefully aligned and the shaft should rotate freely without binding or drag Princess Auto motors with frame 254T and larger are shipped with an opposite drive end bearing lock If front end bearing locks are desired please contact Princess Auto for assistance Build a Guard WARNING Guards must be installed to form a safe and uncompromised perimeter around rotating parts such as couplings pulleys external fans and unused shaft extensions After motor installation is complete a guard of suitable dimensions must be constructed and installed around the motor This guard must prevent personnel from coming in contact with any moving parts of the motor or drive assembly but must allow sufficient cooling air to pass over the motor If a motor mounted brake is installed provide proper safeguards for personnel in case of brake failure 6 For technical questions call 1 800 665 8685 8472888 2 HP Totally Enclosed Fan Cooled Electric Motor V 3 02 All parts should be permanently guarded to prevent accidental contact by personnel Accidental contact with body parts or clothing can cause serious or fatal injury When this motor is installed according to these instructions it complies with the EEC Machinery Directive Electromagnetic Compatibility EMC requirements for CE compliance are met when the incoming power is purely sinusoidal ELECTRICAL INSTALLATION
27. ree of distractions 2 Keep anyone not wearing appropriate safety equipment away from the work area 3 Store devices properly in a safe and dry location Keep devices out of the reach of children 4 Do not install or use in the presence of flammable gases or liquids Visit www princessauto com for more information 3 V 3 02 2 HP Totally Enclosed Fan Cooled Electric Motor 8472888 PERSONAL SAFETY WARNING Wear personal protective equipment approved by the Canadian Standards Association CSA or American National Standards Institute ANSI Personal Protective Equipment 1 Always wear impact safety goggles that provide front and side protection for the eyes 2 Wear gloves that provide protection based on the work materials or to reduce the effects of device vibration 3 Non skid footwear is recommended to maintain footing and balance in the work environment 4 Wear protective clothing designed for the work environment and tool Personal Precautions Control the device personal movement and the work environment to avoid personal injury or damage to the device 1 Do not operate any device when tired or under the influence of drugs alcohol or medications 2 Avoid wearing clothes or jewelry that can become entangled with the moving parts of a device Keep long hair covered or bound 3 Do not overreach when operating a device Proper footing and balance enables better control in unexpected situations SPECIFIC SAFETY PRECAUTIONS DA
28. rs maximum speed rating is not exceeded The wiring fusing and grounding must comply with the Canadian Electrical Code CE or International Low Voltage High Voltage Electrotechnical Commission IEC and local codes If improper rotation direction is detrimental to the load P1 Line 1 P1 Line 1 check the rotation or bump the motor prior to coupling the load to the motor shaft When the motor is coupled tothe P2 P2 load and started it should start quickly and run smoothly T3 Tape Tape If not stop the motor immediately and determine the Ts T8 _ cause Possible causes are low voltage at the motor motor connections are not correct or the load is too heavy Check T2 T2 the motor current after a few minutes of operation and T3 Tape compare the measured current with the nameplate rating T4 T5 p When motor is in F1 Position leads indicated as TOP exit TS F 2 the casing above the center line of the motor and those T4 Line indicated as BOTTOM exit below the center line This F information can be used to identify missing or To Reverse Either Voltage mislabeled leads Interchange T5 amp T8 Visit www princessauto com for more information 7 V 3 02 2 HP Totally Enclosed Fan Cooled Electric Motor 8472888 Maximum Side Loading When an application calls for significant side loading radial load of the motor the application may require roller bearings to avoid reducing the life span of the motor
29. rviced or replaced by a qualified technician Visit www princessauto com for more information 9 V 3 02 2 HP Totally Enclosed Fan Cooled Electric Motor 8472888 Problem s Possible Cause s Suggested Solution s Fuse circuit Power enters control circuit 1 Begin by confirming all contacts are clean breaker overloads but does not reach the motor and tight Examine for obvious damage 2 Test each part of the circuit for power until the problem area is discovered 3 Have a qualified service technician repair or replace the circuit Motor shaft does not turn Disconnect the motor from the load and test when power applied under no load conditions If the shaft does not turn the bearing are immobilized Have the motor serviced or replaced by a qualified technician Motor produces Broken or Reconnect or replace the ground wire and electric shock disconnected ground test for proper ground Hot power lead is connecting Have a qualified technician inspect the motor to the motor frame and repair replace the defective wiring Motor overloads 1 A moving part of the motor may be during operation binding Inspect the motor to see if any parts are touching Check to see the motor s shaft is straight 2 Run the motor under normal load and check the amount of current it is drawing 3 Disconnect the motor from its load and check the current drawn while running under no load 4 Ifthe current draw is ex
30. s propos e s V rifiez si la tension alimente le fusible ou le disjoncteur V rifiez galement si la tension ou l intensit nominale du fusible ou du disjoncteur convient au moteur Celui ci devrait d passer le courant charge maximale du moteur de 25 Surcharge du d marreur de moteur activ e Laissez refroidir et r initialisez ensuite les surcharges Essayez le d marreur avant de red marrer le moteur L interrupteur thermique est ouvert Tension faible ou nulle au niveau du moteur Replacez l interrupteur thermique l tat initial mais soyez prudent puisque le moteur pourrait red marrer automatiquement au moment de la remise l tat initial V rifiez la tension au niveau de chacune des bornes du moteur La tension devrait se situer 10 pr s de la tension indiqu e sur la plaque signal tique du moteur D branchez la charge et appliquez le courant au niveau du moteur Si le moteur fonctionne normalement le probl me se situe au niveau de la charge reli e au moteur Si le moteur ne fonctionne toujours pas demandez un technicien qualifi de le r parer ou de le remplacer Le courant entre dans le circuit de commande mais n atteint pas le moteur 1 Commencez en vous assurant que tous les contacts sont propres et bien serr s V rifiez s il y a des dommages vidents 2 V rifiez chaque partie du circuit afin de d terminer s il y a du courant jusqu ce que
31. s propos e s Vibration ou Jeu longitudinal excessif a 1 Un moteur ou une charge en d s quilibre bruit excessif l int rieur du moteur provoque des vibrations V rifiez s il y a un jeu longitudinal excessif ou des pi ces desserr es 2 R alignez le moteur et la charge V rifiez le jeu longitudinal en essayant de d placer l arbre moteur vers l int rieur et vers l ext rieur Ajoutez des rondelles de r glage du jeu longitudinal au besoin 3 Remplacez le rotor ou le moteur si l arbre est voil Roulements us s ou Un roulement endommag ou mal lubrifi fait mal lubrifi s entendre un bruit Cela peut tre attribuable l usure une quantit insuffisante d huile au niveau des roulements ou une surchauffe du moteur Communiquez avec Princess Auto Ltd pour rem dier au probl me E Visitez www princessauto com pour plus d informations 13
32. s device was designed for a specific function Do not modify or alter this device or use it for an unintended purpose PARTS IDENTIFICATION WARNING Do not operate the device if any part is missing Replace the missing part before operating Failure to do so could result in a malfunction and personal injury CAUTION Use correct material handling equipment to avoid injury Use caution when removing the motor from its packaging Sharp corners may exist on motor shaft motor key sheet metal and other surfaces Remove the parts and accessories from the packaging and inspect for damage Make sure that all items in the parts list are included Use correct material handling equipment to avoid injury Use caution when removing the motor from its packaging Sharp corners may exist on motor shaft motor key sheet metal and other surfaces Contents e Electric Motor ASSEMBLY INSTALLATION Mounting Foot mounted Foot mounted motors should be mounted to a rigid foundation to prevent excessive vibration Shims may be used if the location is uneven Flange mounted Flange mounted motors should be properly seated and aligned If improper rotation direction is detrimental to the load check the rotation or bump the motor prior to coupling the load to the motor shaft V belt drive Mount the sheave pulley close to the motor housing Allow clearance for end to end movement of the motor shaft Do not over tighten belts as this may cause prematu
33. s si on ne respecte pas certaines instructions DANGER Cet avis indique un risque imm diat et particulier qui entra nera des blessures corporelles graves ou m me la mort si on omet de prendre les pr cautions n cessaires AVERTISSEMENT Cet avis indique un risque particulier ou une pratique non s curitaire qui pourrait entra ner des blessures corporelles graves ou m me la mort si on omet de prendre les pr cautions n cessaires ATTENTION Cet avis indique une situation possiblement dangereuse qui peut entra ner des blessures mineures ou mod r es si on ne proc de pas de la fa on recommand e AVIS Cet avis indique un risque particulier ou une pratique non s curitaire qui entra nera des dommages au niveau de l quipement ou des biens mais non des blessures corporelles Visitez www princessauto com pour plus d informations 3 V 3 02 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur 8472888 AIRE DE TRAVAIL Travaillez dans un environnement de travail s curitaire Gardez votre aire de travail propre bien clair e et exempte de toute distraction 2 Assurez vous que les personnes qui ne portent pas l quipement de s curit appropri ne se trouvent pas proximit de l aire de travail 3 Rangez les outils correctement dans un lieu s curis et sec Gardez les outils hors de la port e des enfants 4 N installez pas et n utilisez pas d outils lectriques en pr sence de gaz ou de
34. vi une formation touchant l installation et l utilisation de cet quipement devrait installer ce moteur Un quipement rotatif mal install ou utilis de fa on inad quate peut entra ner des blessures graves ou fatales 1 Avant d installer d utiliser ou de proc der l entretien familiarisez vous avec les points suivants e Publication NEMA MG 2 Norme de s curit dans la construction et guide de s lection d installation et d utilisation des moteurs lectriques e Sp cifications lectriques IEC 60072 1 et m caniques IEC72 1 selon la norme ANSI C51 5 e Code canadien de l lectricit CE pratiques et codes locaux e Norme OSHA 1910 147 intitul e Contr le de l nergie dangereuse verrouillage tiquetage 4 En cas de questions techniques appelez le 1 800 665 8685 8472888 2 10 11 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur V 3 02 Branchez le courant et le c ble de mise la masse au moteur conform ment au Code canadien de l lectricit CE aux exigences de la Commission lectrotechnique internationale CEI et aux codes locaux Pr voyez un protecteur permanent pour emp cher tout contact accidentel des parties du corps ou des v tements avec les pi ces rotatives ou mobiles du moteur Faites attention aux br lures si le moteur est chaud La clavette de l arbre doit tre retenue avant de d marrer le moteur Les boulons de fixation devraient tre fabriqu s
35. vous ayez d tect le probl me 3 Demandez un technicien de service qualifi de r parer ou de remplacer le circuit 10 En cas de questions techniques appelez le 1 800 665 8685 8472888 Moteur lectrique de 2 CV enti rement enferm refroidi par ventilateur V 3 02 Probl me s Surcharge au niveau du fusible disjoncteur Cause s possible s Un fusible est saut ou un disjoncteur est ouvert Solution s propos e s V rifiez si la tension alimente le fusible ou le disjoncteur V rifiez galement si la tension ou l intensit nominale du fusible ou du disjoncteur convient au moteur Celui ci devrait d passer le courant charge maximale du moteur de 25 Surcharge du d marreur de moteur activ e Laissez refroidir et r initialisez ensuite les surcharges Essayez le d marreur avant de red marrer le moteur Tension faible ou nulle au niveau du moteur V rifiez la tension au niveau de chacune des bornes du moteur La tension devrait se situer 10 pr s de la tension indiqu e sur la plaque signal tique du moteur D branchez la charge et appliquez le courant au niveau du moteur Si le moteur fonctionne normalement le probl me se situe au niveau de la charge reli e au moteur Si le moteur ne fonctionne toujours pas demandez un technicien qualifi de le r parer ou de le remplacer Le courant entre dans le circuit de commande mais n atteint pas le moteur

Download Pdf Manuals

image

Related Search

Related Contents

Öl-Brennwertkessel TG 12 EK  BRIEF USER MANUAL FOR NABET DGET  LinkTenn 32 User Manual  Agrea HM700 Web設定マニュアル  Guida di riferimento Integrated  ATMT N-LITE MP140 User's Manual  Targus TSM103EU    外部指向性アンテナ 取扱説明書 ↓ ↓  Philips DVD+R 16x 4.7GB / 120min SP (100)  

Copyright © All rights reserved.
Failed to retrieve file