1. Installation Screw the LEO RECORD Ei into the female pressure port and tighten using the hexagon of the transducer pressure connection max torque 50 Nm The trans ducer is secured to the housing by a lock nut Aligning the face Slacken the lock nut at the housing using two open ended spanners The display of the LEO RECORD Ei can now be rotated in relation to the trans ducer Move the face to the desired position and tighten the lock nut 5 Si une pression ne peut tre affich e le message OFL overflow ou UFL under flow appara t l cran 6 Si une pression mesur e est en dehors de l tendue de mesure la derni re va leur valide de pression est affich e clignotante avertis sement de surcharge 7 La lisibilit de l affichage peut tre affect e par une temp rature exc dant 0 60 C 8 L affichage de la charge de la batterie ne comporte que 2 tats 0 BatLow et 100 9 L horloge interne du LEO RECORD Ei est aussi actu alis e lorsque l instrument est arr t Le r glage de l horloge a lieu automatique ment lors d une configuration avec le logiciel Logger 5 10 Apr s un changement de batterie le LEO RECORD Ei doit tre reconfigur au moyen du logiciel Logger 5 11 Si un enregistrement est en cours la pression est affi ch e selon l intervalle pro gramm au plus tard toutes les 5 secondes Installation Visser LEO RECORD Ei sur linstallatio
2. ter le LEO RECORD Ei ouvrir le compartiment renfer mant la batterie et proc der son remplacement Lors du montage du couvercle de la batterie assurez vous que le joint d tanch it est bien en place Dur e de vie de la batterie jusqu 5 ans selon l intervalle de mesure Etendues de mesure Calibration La fonction ZERO permet de d finir un nouveau z ro la pression appliqu e Le r glage usine du z ro pour les tendues de mesure lt 61 bar absolu est effectu au vide 0 bar absolu Pour les mesures de pression n cessitant une r f rence la pression atmosph rique activer ZERO Set la pression atmosph rique Pour les tendues de mesure gt 61 bar absolu ou pour instru ments avec un capteur de pres sion relative tiquette marqu e avec Range rel le r glage usine du z ro est effectu la pression atmosph rique Schnittstelle RS485 Auf der R ckseite befindet sich die Schnittstelle Flanschdose Fischer Serie 103 Das bertragen der Messwerte auf den PC erfolgt ber den Schnittstellenkonverter K 103A RS232 oder K 114A USB Die PC Software dazu finden Sie auf unserer Homepage Achtung Der Anschluss f r die Schnittstelle RS485 darf nur ausserhalb des explosionsge f hrdeten Bereiches verwendet werden Allg Sicherheitshinweise Bitte beachten Sie bei Montage und Betrieb des digitalen Ma nometers die entsprechenden nationalen Sicherheit
3. Warten bis Ger t im Messmodus ist 3 s gt 2 x dr cken der SELECT Taste MANO erscheint gt Druck auf ENTER rEC Strt erscheint gt 2 x dr cken der SELECT Taste ZERO SET erscheint gt Druck auf ENTER Der neue Nullpunkt ist gesetzt Das Ger t befindet sich wieder im Messmodus Hinweise 1 Die Funktionen und Ein heiten k nnen auch durch konstantes Dr cken der SELECT Taste angew hlt und durch Loslassen zur Aktivie rung freigegeben werden 2 Wird die angew hlte Funk tion oder Einheit nicht inner halb von 5 Sekunden durch die ENTER Taste aktiviert kehrt LEO RECORD Ei ohne nderung einer Einstellung in den Messmodus zur ck 3 Beim Ein und Ausschalten bleiben die zuvor get tigten Einstellungen erhalten 4 Der Record Zustand wird im Messmodus immer im unteren Display angezeigt run Aufzeichnung l uft PrEP warten auf Startbe dingung End Aufzeich nung gestoppt ZERO rES Sets the pressure zero to factory setting followed by the unit selec tion bar mbar hPa kPa MPa PSI kp cm cmH O mH 0 inH O ftH O mmHg inHg Example Setting a new Zero Reference gt Turn on the instrument by shortly pressing SELECT gt Wait for the instruments measuring mode 3 s gt Press the SELECT key 2 times MANO appears gt Press ENTER appears rEC Strt gt Press the SELECT key 2 times ZERO SET appears gt Press ENTER The new Zero ref
4. exceeded This guarantees that the capa citance limit for the basic vol tage level is not exceeded on reintroducing the equipment to the hazardous zone The following battery type must be used in explosive atmos pheres Tadiran SL 760 3 6 V Lithium battery The battery may be changed in side the zone with a potentially explosive atmosphere Do not conduct such processes in close proximity which gene rate charged particles air ioniser high voltage electrodes etc Marking La connexion au dos de l appareil pour l interface RS485 ne doit tre utilis e qu en de hors de la zone explosible En raison de la valeur de capa cit int rieure la tension maxi male de s curit pouvant tre appliqu e est limit e Um 6 3 V et la puissance de 0 9 W ne doit pas tre d pass e On a ainsi l assurance qu en cas de r introduction de l appareil dans la zone explosible la ca pacit limite pour le niveau de tension pris comme base ne sera pas d pass e Seule l utilisation des types de batteries suivants sont autoris s lorsque le manom tre est install en zone explosible Tadiran SL 760 Lithium 3 6 V La batterie peut tre chang e dans la zone explosible Le manom tre num rique ne doit se trouver proximit d aucun proc d pouvant g n rer des particules et autres l ments charg s d lectricit statique ioniseur lectrode haute ten sion etc Marquage amp I
5. 8404 Winterthur Tel 052 235 25 25 Tel 07745 92140 08 2013 Fax 052 235 25 00 Fax 07745 9214 50
6. CT et s lectionn es d s rel che ment de la touche 2 Si la fonction ou lunit choisie n est pas valid e dans les 5 secondes avec la touche ENTER le manom tre bascule automatique ment sans modification des r glages en mode mesure 3 La mise en route et l arr t de l instrument ne modifient pas les r glages pr c demment valid s 4 Le statut de l enregistrement est toujours indiqu en mode mesure dans la partie inf rieure de laffichage run enregistrement est actif PrEP attendre les condi tions de d marrage End enregistrement termin 5 Kann ein Druck auf dem Display nicht dargestellt wer den erscheint OFL over flow oder UFL underflow auf der Anzeige 6 Wird ein Druck ausserhalb des Messbereiches des Ger tes angelegt wird der letzte g ltige Druckwert blin kend angezeigt berlast warnung 7 Bei Temperaturen ausser halb 0 60 C kann die Les barkeit des Displays beein tr chtigt werden 8 Die PC Software und das LEO RECORD Ei zeigen nur 2 Batteriezust nde 0 BatLow Anzeige und 100 9 Die interne Uhr bei LEO RECORD Ei wird auch im ausgeschalteten Zustand nachgef hrt Das Stellen der Uhr erfolgt automatisch bei einer Konfiguration mit der PC Software Logger 5 10 Nach einem Batteriewechsel ist eine Neukonfiguration des LEO RECORD Ei mit der PC Software Logger 5 n tig 11 Ist ein Record aktiv wird die Anzeige des Druckes entspre chen
7. I2G PTB 05 ATEX 2012 X IECEx PTB 13 0028 X Ex ia IIC T4 Gb Zubeh r Ersatzteile Accessories Spare Parts Accessoires Pieces Detachees Battery Tadiran SL 760 Lithium 3 6 V AA Order Number 557005 0006 Interface Cable K 114A USB RS485 Order Number 309010 0075 Interface Cable K 103A RS232 RS485 Order Number 309010 0002 KELLER Software CD Order Number 750505 0001 free download under www keller druck com Tragetasche Carrying bag Sacoche de transport Order Number 309030 0003 Tragekoffer Carrying Case Mallette de transport Order Number 309025 0050 Me Konformit tserkl rung F r die folgenden Erzeugnisse Eigensicheres digitales Manometer LEO RECORD Ei Declaration of Conformity Herewith we declare that the following products Intrinsically Safe Digital Declaration de Conformite Nous attestons que les pro duits Manom tres num LEO RECORD Manometer LEO RECORD Ei Ei de s curit intrins que wird hiermit best tigt dass sie den Anforderungen folgender EG Richtlinien entsprechen EMV Richtlinie 2004 108 EG Ex Schutz Richtlinie ATEX 94 9 EG Dieses digitale Manometer LEO RECORD Ei wurde entspre chend den Normen meet the basic requirements which are established in the guidelines of the European Community Directive 2004 108 EC Directive ATEX 94 9 CE As criteria the following norms for this Intrinsically Safe Manometer
8. LEO RECORD Ei Aktueller Druckwert Actual Pressure Value Valeur de pression actuelle Statusanzeige Status Indication Affichage du statut ENTER SELECT Druckanschluss Pressure Connection Raccord pression Eigensicheres digitales Manometer mit Speicherfunktion zum Einsatz in explosionsgef hrdeten Bereichen Intrinsically Safe Digital Manometer with Record Function for use in Hazardous Applications Manom tre num rique enregistreur de s curit intrins que pour utilisation en zones explosibles Beschreibung und Einsatz Eigensicheres digitales Mano meter zur Druckanzeige mit Speicherfunktion f r den Ein satz in explosionsgef hrdeten Bereichen Die technischen Daten des digi talen Manometers entnehmen Sie bitte dem entsprechenden Datenblatt oder den vereinbar ten Spezifikationen Inbetriebnahme und Funktionen LEO RECORD Ei hat zwei Be dientasten Mit der linken Taste SELECT werden die Funk tionen sowie die Druckeinheiten angew hlt Die rechte Taste ENTER aktiviert die angew hlte Funktion oder Druckeinheit Einschalten Ein Druck auf SELECT schaltet das Ger t ein Das Ger t zeigt zuerst den werkseitig abge glichenen Druckbereich oben und die Softwareversion Jahr Woche Danach ist das Ger t betriebsbereit und zeigt im obe ren Display den aktuellen Druck im unteren Display den Record Status Das Ger t verf gt ber folgende Funktionen OFF Schaltet das Ger t aus und b
9. LEO RECORD Ei are applied r pondent aux exigences pr vues par les directives de la Communaut Europ enne Directive CEM 2004 108 CE Directive ATEX Ex 94 9 CE Le manom tre LEO RECORD Ei de s curit intrins que r pond aux normes EN 61000 6 1 2007 EN 61326 2 3 2006 EN EN 61000 6 2 2005 60079 0 2012 EN 61000 6 3 EN 60079 11 2012 2007 EN 61000 6 4 2007 gepr ft und die EG Baumusterpr f bescheinigung unter PTB 05 ATEX 2012 X und Anhang 1 bis 4 erteilt Diese Erkl rung wird verant wortlich f r den Hersteller and the EC examination certifi cate under PTB 05 ATEX 2012X and annex 1 to 4 is given This declaration is given for the manufacturer et la suivante attestation d examen CE de type PTB 05 ATEX 2012 X et annexe de 1 4 a t d livr e La pr sente d claration est fournie pour le fabricant KELLER AG f r Druckmesstechnik St Gallerstrasse 119 CH 8404 Winterthur abgegeben durch die in full responsibility by par KELLER GmbH Schwarzwaldstrasse 17 D 79798 Jestetten Jestetten 27 August ao t 2013 d Ze Hannes W Keller Gesch ftsf hrender Inhaber Managing Owner President Directeur General mit rechtsg ltiger Unterschrift with legally effective signature d ment autoris signer KELLER AG St Gallerstrasse KELLER GmbH Schwarzwaldstrasse 17 D 79798 Jestetten www keller druck com 119 CH
10. d dem Record Intervall nachgef hrt sp testens je doch alle 5 Sekunden Installation Das LEO RECORD Ei in den Druckstutzen drehen und ber den Sechskant des Aufnehmers Druckanschluss anziehen max Drehmoment 50 Nm Eine Gegenmutter sichert den Auf nehmer gegen das Geh use Ausrichten der Frontseite L sen der Gegenmutter am Geh use mit zwei Gabelschl s seln Die Anzeige des LEO RECORD Ei l sst sich sich jetzt gegen den Aufnehmer verdrehen Ausrichten der Frontseite in die optimale Richtung und Anziehen der Gegenmutter 5 If a pressure can not be represented on the display OFL overflow or UFL underflow appears on the display 6 If the actual pressure goes beyond the measuring range the last valid pressure value starts flashing on the display overload warning 7 Temperatures outside of 0 60 C could impair the readability of the display 8 Both the PC Software and the LEO RECORD Ei indi cate the battery condition in only 2 ways 0 BatLow display and 100 9 The internal clock of LEO RECORD Ei is also updated when the instrument is turned off The clock is automatically upated by the PC software Logger 5 when writing a record configuration 10 After a battery change LEO RECORD Ei has to be recon figured with the PC Soft ware Logger 5 11 lf a record is active the display of the pressure is updated according to the set record interval at least every 5 seconds
11. e bungsluftdruck als Nullpunkts referenz abgeglichen The display of the LEO RECORD Ei can be rotated by 355 It can also be installed horizontally or upside down Battery Change Battery Life When the battery starts weak ening a low battery warning BAT LOW will appear in the display Battery change Please tum off the instrument before changing the battery Open the instrument by turning the display ring be yond the limit stop Disconnect the battery Remove weak bat tery and insert new one When reassembling make sure that the O ring remains imbed ded in the cover The battery life is up to 5 years depending on measuring cycle Ranges Calibration The ZERO function allows to set any pressure value as a zero reference The factory setting of the pressu re zero for the ranges lt 61 bar absolute is at vacuum 0 bar absolute For relative pressure measurements activate ZERO SEt at ambient pressure Instruments gt 61 bar absolute or instruments with a relative pressure sensor label marked with Range rel are calibrated with the zero at atmospheric pressure e La face avant de LEO RECORD Ei est orientable sur 355 Montages horizontal et invers possibles Remplacement de la batterie Dur e de vie de la batterie L indication batterie faible est signal e par l apparition du sigle batterie BAT LOW sur l cran Remplacement de la batterie arr
12. e endet einen aktiven Record MANO Gibt nachstehende Funktionen frei rEC Strt Startet einen Record mit der ak tuellen Konfiguration die ber die Software eingestellt wurde rEC StoP Beendet einen aktiven Record ZERO SEE Setzt einen neuen Druck Nullpunkt Description and Application Intrinsically safe manometer for pressure indication with record function for use in hazardous environments The technical data of the digital manometer can be taken from the corresponding data sheet or from the agreed specifications Turn On and Functions LEO RECORD Ei has two operating keys The left key SELECT serves to select the functions and the pressure units The right key ENTER activates the selected function or pressure unit Turn on Pressing the SELECT key turns the instrument on The instrument first displays the full scale pressure range top display and the software ver sion year week The instru ment is then ready for use and indicates the actual pressure top display and the record status bottom display The instrument has the following functions OFF Turns off the instrument and ends an active record MANO Releases the following func tions rEC Strt Starts a record with the ac tual configuration set via the software rEC StoP Ends an active record ZERO SEE Sets a new pressure zero reference BECH Description et Application Ce manom ire d
13. e pression num rique enregistreur de s curit intrins que est utilisable en zones explosibles Les sp cifications techniques du manom tre sont celles figurant sur la fiche technique correspondante ou les sp cifi cations convenues Mise en route et fonctions LEO RECORD Ei poss de 2 touches La touche de gauche SELECT permet de s lection ner les fonctions et l unit de pression La touche de droite ENTER valide la fonction ou Punit de mesure s lectionn e D marrage Une action sur SELECT met en route l instrument L instrument affiche d abord le type d tendue de mesure calibr e en haut et la version du logiciel ann e semaine L instrument est alors en service l indique la pression actuelle en haut et le statut de l enregistrement en bas Le manom tre dispose des fonctions suivantes OFF Arr te l instrument et stoppe l enregistrement en cours MANO Donne acc s aux fonctions suivantes rEC Strt D marre un enregistrement avec la configuration actu ellement programm e rEC StoP Stoppe un enregistrement actif ZERO SEI Enregistre un nouveau z ro de pression de r f rence ZERO rES Setzt den Druck Nullpunkt auf Werkseinstellung danach folgt die Einheiten wahl bar mbar hPa kPa MPa PSI kp cm cmH O mH 0 inH O ftH O mmHg inHg Beispiel Setzen eines neuen Nullpunktes gt Einschalten durch kurzes Dr cken von SELECT gt
14. erence is set The instrument returns to the measuring mode Notes 1 The functions and units can also be called up by keeping the SELECT key depressed Releasing the key enables the displayed function or unit to be activa ted with the ENTER key 2 If the selected function or unit is not activated within 5 seconds with the ENTER key LEO RECORD Ei returns to the measuring mode with out changing any settings 3 Turning LEO RECORD Ei on and off does not influence any of the previous settings 4 In the measuring mode the record status is always indi cated on the bottom display run record is running PrEP waiting for start condition End recording stopped ZERO rES Restaure le zero de pression r gl en usine puis suit la s lection de l unite bar mbar hPa kPa MPa PSI kp cm cmH O mH O inH O ftH O mmHg inHg Exemple Enregistrement d un nouveau zero gt Mise en route par une action breve sur SELECT gt Attendre que l instrument passe en mode mesure 3 s gt Appuyer 2 fois sur la touche SELECT MANO s affiche gt Appuyer sur ENTER rEC Strt s affiche gt Appuyer 2 fois sur la touche SELECT ZERO SET s affiche gt Appuyer sur ENTER Le nouveau z ro est enregistr L instrument se trouve nou veau en mode mesure Remarques 1 Les fonctions et unit s peu vent galement tre appe l es par une action mainte nue sur la touche SELE
15. ic oil de termined by production flow Please also note the correspon ding data sheet Special Conditions for Safe Use The digital manometer LEO RECORD Ei is an intrinsically safe apparatus it can be ope rated in explosive atmospheres Operating ambient temperature 20 C and 65 C Connect the pressure port of the digital Manometer to neutral earth to ground 6 Interface RS485 Un c ble convertisseur K 103A RS232 ou K 114A USB peut tre connect l arri re du manom tre Fischer S rie 103 pour une liaison avec un PC Les mesures peuvent alors tre transf r es sur le PC Le PC logiciel correspondant est disponible sur notre Home page Note La connexion au dos de l appareil pour l interface RS485 ne doit tre utilis e qu en de hors de la zone explosible Fischer Series 103 RS485A RS485B Consignes de securite Lors du montage et de l utili sation du manom amp tre num rique veiller respecter les r amp glemen tations de s curit nationale ainsi que la r glementation nationale concernant l utilisation en zones explosibles L installation du manom tre nu m rique doit tre effectu e sur des syst mes hors pression Pour des pressions z 61 bar le raccord pression peut pr senter des traces d huile hydraulique du fait de nos imp ratifs de production Veuillez galement consulter la fiche technique du manom tre Conditions particuli re
16. n et le serrer l aide de l amp crou 6 pans couple serra ge max 50 Nm Un contre crou maintient le cap teur sur le bo tier Orientation du plan de la face avant Desserrer le contre crou du bo tier laide de deux cl s plates Le bo tier peut alors tourner par rapport au capteur Orienter la face avant et resser rer le contre crou Die Anzeige des LEO RECORD Ei l sst sich um 355 drehen Dadurch ist ein horizontaler oder auf Kopf gestellter Einbau m glich Batteriewechsel Batterie Lebensdauer Bei schwacher Batterie leuchtet im Display das Batteriesymbol BAT LOW auf Batteriewechsel Bitte Ger t ausschalten Drehen Sie den An zeigeteil Ring ber den Anschlag hinaus bis er sich aus dem Ge h useteil l st Batteriefach ffnen und die Batterie wechseln Achten Sie bei der Montage des Batteriefachdeckels darauf dass der O Ring richtig positioniert im Verschlussdeckel liegt Die Batterie Lebensdauer ist je nach Messintervall bis zu 5 Jahre Bereich Abgleich Die ZERO Funktion erlaubt es einen beliebigen Druckwert als neue Nullpunktsreferenz fest zulegen Die Werkseinstellung des Druck Nullpunktes f r Bereiche lt 61 bar absolut ist bei Vakuum 0 bar absolut F r Relativdruckmes sungen ist ZERO GET bei Um gebungsluftdruck zu aktivieren Ger te gt 61 bar absolut oder Ger te mit relativem Drucksen sor Bezeichnung auf Etikette Range rel werden mit Umg
17. s pour une utilisation s re Le manom tre LEO RECORD Ei est un mat riel de s curit intrins que II peut tre utilis en atmosph res explosibles La temp rature ambiante d utili sation est de 20 65 C Relier la terre le raccord pres sion du manom tre num rique Der r ckseitige Anschluss f r die Schnittstelle RS485 darf nur aus serhalb des explosionsgef hrdeten Bereiches verwendet werden Dabei darf wegen der inneren Kapazit ten nur eine sicherheits technische Maximalspannung von Um 6 3 V angelegt und die Leistung von 0 9 W nicht ber schritten werden Hierdurch ist gew hrleistet dass bei Wiedereinf hrung des Betriebsmittels in den Ex Be reich die Grenzkapazit t f r das zugrundegelegte Spannungs niveau nicht berschritten wird F r den Einsatz in explosiver Umgebung darf ausschliesslich folgender Batterie Typ verwen det werden Tadiran SL 760 3 6 V Lithium Batterie Die Batterie darf innerhalb des explosionsgef hrdeten Bereiches gewechselt werden Es d rfen keine Prozesse in unmittelbarer N he durchge f hrt werden welche geladene Teilchen erzeugen lonisatoren Hochspannungselektroden etc Kennzeichnung The connection at the rear for the RS485 interface may only be used outside the zone with a potentially explosive atmosphere Due to the internal capacitances only a safe maximum voltage of Um 6 3 V may be applied and the power of 0 9 W may not be
18. svorschrif ten sowie die jeweiligen Lan desvorschriften hinsichtlich des Ex Einsatzes Montieren Sie das digitale Mano meter nur an Systeme welche sich in drucklosem Zustand befinden Bei Druckbereichen 2 61 bar k n nen die Druckanschl sse pro duktionsbedingt Restmengen an Hydraulik l aufweisen Bitte beachten Sie auch das zugeh rige Datenblatt Besondere Bedingungen f r den sicheren Einsatz Das digitale Manometer LEO RECORD Ei ist ein Eigensiche res Ger t Es kann in explosiver Atmosph re betrieben werden Umgebungstemperatur f r den Einsatz 20 C und 65 C Erden Sie den Druckanschluss des Digitalen Manometers Interface RS485 The interface converter K 103A RS232 or K 114A USB can be connected at the back of the manometer Fischer plug Series 103 allowing the data transfer to the PC The corresponding PC software can be found on our web site Note The connection for the RS485 interface may only be used out side the zone with a potentially explosive atmosphere nc nc nc General Safety Instructions When installing and operating the digital manometer attention should be paid to the correspon ding national safety regulations and to the relative country regulations concerning the Ex application Only mount the digital mano meter onto unpressurized sys tems On pressure ranges gt 61 bar the pressure connections could show residual hydraul