Home

User Manual

image

Contents

1. A Caution risk of danger refer to the operating manual before use A Caution risk of electric shock Earth ground Terminal E Fuse ce Conforms to European Union directives Ej The equipment is protected throughout by double insulation or reinforced insulation C This product has been to tested to the requirements of CAN CSA C22 2 NO 61010 1 second edition including Amendment 1 or a later version of the same standard incorporating the same level of testing requirements INTRODUCTION This meter is a compact 3 1 2 digit digital multimeter for measuring DC and AC voltage DC current Resistance Diode and Continuity SAFETY The multimeter has been designed according to IEC 61010 concerning electronic measuring instruments with a measurement category CAT II 250V and Pollution degree 2 IMPORTANT SAFETY PRECAUTIONS WARNING Read and understand all instructions before using this tool The operator must follow basic precautions to reduce the risk of personal injury and or damage to the equipment Before allowing someone else to use this tool make sure they are aware of all safety information WARNING The warnings cautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur common sense and caution are factors that cannot be built into this product but must be supplied by the operator NOTE Keep this manual for safety warnings
2. Verify the meter is operating correctly by measuring a known voltage before use The multimeter accuracy is specified for a period of 1 year after calibration at 18 C 28 C with relative humidity up to 75 The tables following each measurement method displays the accuracy specifications in the following form of Reading Number of Least Significant Digits MEASURING DC VOLTAGE CAUTION The Digital Multimeter is a CAT II device Measuring a DC voltage that exceeds 250 V will exceed the safety limits of the device and could result in an electric shock to the user or damage to the meter 1 Connect the black test lead to the COM Jack and the red test lead to the V Jack 2 Setthe range switch to desired DC range X ifthe voltage to be measured is not known beforehand set the range switch to the highest range and then turn it down range by range until satisfactory resolution is obtained 3 Connect the test leads across the source or circuit to be measured 4 The LCD will display the reading The polarity indicated is for the red test lead NOTE In the range 200mV when the test leads are in an open circuit state the display will show a random number It is normal and does not affect measurement For technical questions call 1 800 665 8685 7 V 2 0 Digital Multimeter 8347676 DC VOLTAGE ACCURACY Range Resolution Accuracy 200mV 100pV 0 5 5 2 000mV 1mV 0 8 5 20V 10mV 200V 100mV 250V 1V
3. P La chute de tension directe approximative de la diode sera affich e Tension de circuit ouvert Environ 2 8 V Courant d essai Environ 1 mA ESSAI DE CONTINUIT REMARQUE Avant de proc der un essai de continuit assurez vous que tout le courant alimentant le circuit est enti rement coup et que tous les condensateurs sont compl tement d charg s Un essai de continuit est une v rification de r sistance qui vise d terminer si un circuit lectrique est ouvert ou ferm 1 Branchez le fil d essai noir sur la prise COM et le fil d essai rouge sur la prise mA Q 2 R glez le s lecteur de plage la position de continuit a 3 Branchez les fils d essai Sur le circuit mesurer 4 Sila r sistance du circuit est inf rieure 30 Q environ l avertisseur sonore int gr retentira EXACTITUDE DE LA CONTINUIT Plage Description Lavertisseur sonore int gr retentira si la r sistance est inf rieure 30 Q environ Tension de circuit ouvert Environ 2 8 V ENTRETIEN Entretenez l outil avec soin Un outil en bon tat sera efficace plus facile contr ler et pr viendra les probl mes inutiles 2 Suivez les instructions pour lubrifier et remplacer les accessoires 3 Inspectez p riodiquement les raccords de l outil Demandez un technicien autoris de r parer ou de remplacer les composants endommag s ou us s 4 Veillez ce que l tiquette et la plaque sig
4. precautions operating inspection and maintenance instructions WORK AREA Operate in a safe work environment Keep your work area clean and well lit Do not use in the presence of flammable gases or liquids Keep anyone not wearing the appropriate safety equipment away from the work area Minimize distractions in the work environment Distractions can cause you to lose control of the tool Store tools properly in a safe and dry location to prevent rust or damage Always lock up tools and keep them out of the reach of children DN Co No EE 4 For technical questions call 1 800 665 8685 8347676 Digital Multimeter V 2 0 PERSONAL SAFETY CAUTION Wear protective equipment approved by the Canadian Standards Association CSA or American National Standards Institute ANSI when using the tool 1 Head Protection a Always wear impact safety goggles that provide front and side protection for the eyes b Wear the appropriate rated dust mask or respirator when working around metal wood and chemical dusts or mists Wear earplugs if the power tool or work environment is noisy Wear a full face shield if your work creates metal filings or wood chips Wear a hard hat to protect your head from falling objects 2 Gloves a The gloves should provide protection based on the work materials b Wear suitable gloves to reduce the effects of vibration 3 Protective Clothing a Wear protective clothing designed for the work environment an
5. et sec pour emp cher la rouille ou les dommages Gardez toujours les outils dans un endroit verrouill et hors de la port e des enfants S CURIT PERSONNELLE ATTENTION Portez de l quipement de protection homologu par l Association canadienne de normalisation CSA ou l American National Standards Institute ANSI quand vous utilisez l outil 1 Protection de la t te a Portez toujours des lunettes antiprojections qui offrent une protection frontale et lat rale des yeux b Portez un masque antipoussi res ou un appareil respiratoire nominal appropri lorsque vous travaillez o il y a des poussi res et des vapeurs provenant du m tal du bois ou de produits chimiques Portez des bouchons d oreilles si l outil lectrique ou l environnement de travail est bruyant Portez un cran facial panoramique si votre travail produit des limailles ou des copeaux de bois Portez un casque de protection pour vous prot ger de la chute d objets Gants a Les gants doivent prot ger en fonction des mat riaux travaill s b Portez des gants appropri s pour r duire les effets des vibrations coco V tements de protection a Portez des v tements de protection concus pour l environnement de travail et pour l outil Par exemple des v tements en tissu non conducteur ou en tissu trait pour r sister aux liquides ou aux produits corrosifs Protection des pieds a Portez des chaussures embout d acier ou coquilles d acier p
6. fil d essai sous tension en premier V rifiez si le multim tre fonctionne correctement en mesurant une tension connue avant de l utiliser L exactitude du multim tre est sp cifi e pour une p riode d un an apr s l talonnage de 18 28 C avec une humidit relative jusqu 75 Les tableaux suivant chaque m thode de mesurage pr sentent les sp cifications d exactitude sous la forme suivante de lecture nombre des caract res les moins importants MESURE DE TENSION C C ATTENTION Le multim tre num rique est un appareil de type CAT II Si on obtient une tension c c qui d passe 250 V on d passera les limites de s curit de l appareil et il pourrait en r sulter un choc lectrique pour l utilisateur ou des dommages pour le multim tre Branchez le fil d essai noir sur la prise COM et le d d essai rouge sur la prise V 2 R glez le s lecteur de plage la plage c c d sir e X Si la tension mesurer n est pas connue d avance s lectionnez d abord la plage la plus lev e du s lecteur de plage puis r duisez progressivement la plage suivante jusqu l obtention d une r solution satisfaisante 3 Branchez les fils d essai sur la source ou le circuit mesurer 4 LACL affichera la lecture La polarit indiqu e concerne le fil d essai rouge REMARQUE Dans la plage de 200 mV lorsque les fils d essai pr sentent un circuit ouvert l cran affichera un num ro al atoire Ceci est normal et
7. n a aucun impact sur les mesures 8 Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 8347676 EXACTITUDE DE LE TENSION C C Multim tre num rique Plage R solution Exactitude 200 mV 100 pV 0 5 5 2 000 mV 1mV 0 8 5 20 V 10 mV 200 V 100 mV 250 V 1V Imp dance d entr e 10 millions Q Tension max d entr e permise 250 V c c c a rms MESURE DE TENSION C A ATTENTION Le multim tre num rique est un appareil de type CAT II Si on obtient une tension c a qui d passe 250 V rms on d passera les limites de s curit de l appareil et il pourrait en r sulter un choc lectrique pour l utilisateur ou des dommages pour le multim tre 1 2 3 4 Branchez le fil d essai noir sur la prise COM et le fil d essai rouge sur la prise V R glez le s lecteur de plage la plage c a d sir e V Si la tension mesurer n est pas connue d avance s lectionnez d abord la plage la plus lev e du s lecteur de plage puis r duisez progressivement la plage suivante jusqu l obtention d une r solution satisfaisante Branchez les fils d essai sur la source ou le circuit mesurer L ACL affichera la lecture EXACTITUDE DE LA TENSION C A Plage R solution Exactitude 200 V 100 pV 1 2 10 250 V 1V Plage de fr quence 40 400 Hz Protection contre les surcharges 250 V rms R ponse Moyenne talonn e en rm
8. pi ces et les accessoires de la boite Conservez les mat riaux d emballage jusqu ce que vous ayez inspect avec soin et install ou utilis l outil de mani re satisfaisante 2 Assurez vous que tous les articles sur la liste de pi ces sont pr sents 3 Inspectez les pi ces attentivement pour vous assurer que les outils et les accessoires n ont pas t endommag s pendant le transport AVERTISSEMENT Ne faites pas fonctionner l outil si des pi ces sont manquantes Remplacez les pi ces manquantes avant l utilisation Le non respect de cet avertissement peut entrainer une d fectuosit et des blessures graves IDENTIFICATION DES PIECES Contenu e Multim tre num rique e Fil d essai noir n gatif e Fild essai rouge positif REMARQUE Lorsque ce manuel fait r f rence un num ro de pi ce il fait r f rence la liste des pi ces comprise Le multim tre est d j assembl Les deux fils d essai sont branch s dans la prise correspondante tout d pendant de la fonction choisie UTILISATION ATTENTION Pour viter d endommager le multim tre ou l quipement mesurer suivez ces directives 1 D branchez l alimentation du circuit et d chargez tous les condensateurs avant de v rifier la r sistance la diode ou la continuit 2 Utilisez les bornes la fonction et la plage appropri es pour vos mesures 3 Avant de mesurer le courant v rifiez le fusible du multim tre et coupez l alimentation du ci
9. sont compl tement d charg s 1 Branchez le fil d essai noir sur la prise COM et le fil d essai rouge sur la prise mA Q 2 R glez le s lecteur de plage la plage W d sir e 3 Branchez les fils d essai sur la charge mesurer 4 Notez la lecture qui apparait l cran Le multim tre prend plus de temps pour stabiliser une lecture lorsque la r sistance est 1 million W Ceci est normal pour les mesures de r sistance lev es 1 est affich pour indiquer un d passement de plage lorsque l entr e n est pas connect e EXACTITUDE DE LA R SISTANCE Plage R solution Exactitude 200 Q 0 10 Q 1 0 5 2 000 Q 1Q 0 8 5 20 000 Q 10 o 200 000 Q 100 Q 2 millions Q 1000 Q 1 2 5 20 millions Q 10 000 Q 1 2 10 Tension max du circuit ouvert Environ 2 8 V DIODE DE MESURE 1 Branchez le fil d essai noir sur la prise COM et le fil d essai rouge sur la prise mA Q R glez le s lecteur de plage la position de la diode Pr Branchez le fil d essai rouge sur l anode de la diode v ritier et le fil d essai noir sur la cathode L afficheur indiquera la chute de tension directe approximative de la diode unit de lecture mV Si la connexion est invers e le num ro 1 apparaitra l cran Bon 10 Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 8347676 Multim tre num rique V 2 0 EXACTITUDE DE DIODE Plage Description
10. the correct tool for the job Do not force a tool or attachment to do the work of a larger industrial tool Maximize tool performance and safety by using the tool for its intended task 2 This tool was designed for a specific function Do not modify or alter this tool or use it for an unintended purpose 3 Securely hold this tool using both hands unless it is designed for single hand use Using a tool with only one hand can result in loss of control 4 Maintain tools with care see Maintenance 1 Carefully remove the parts and accessories from the box Retain packaging material until you have carefully inspected and satisfactorily installed or operated the tool 2 Make sure that all items in the parts list are included 3 Inspect the parts carefully to make sure the tools and accessories were not damaged while shipping WARNING Do not operate the tool if any part is missing Replace the missing part before operating Failure to do so could result in a malfunction and serious personal injury PARTS IDENTIFICATION Contents e Digital Multimeter e est Lead Black negative e Test Lead Red positive ASSEMBLY NOTE When this manual refers to a part number it refers to the included parts list The multimeter comes preassembled The two test leads are plugged into the appropriate jack based on the function chosen 6 For technical questions call 1 800 665 8685 8347676 Digital Multimeter V 2 0 OPERATION CAUTION To avo
11. vous placez pas la terre lorsque vous utilisez le multim tre 12 Sachez qu une prise d entr e reli e un circuit d alimentation peut galement cr er un courant ventuel vers toutes les autres prises d entr e 13 CAT II La cat gorie de mesure ll est pour les mesures effectu es sur les circuits qui sont branch s directement sur une installation de basse tension p ex les mesures d appareils lectrom nagers d outils portatifs ou d quipement similaire N utilisez pas le multim tre pour des mesures se trouvant dans les cat gories de mesure III et IV UTILISATION ET ENTRETIEN DE L OUTIL 1 Utilisez le bon outil pour la t che effectuer N utilisez pas d outil ou d accessoire pour effectuer le travail d un outil industriel plus gros Maximisez la performance de l outil et la s curit en utilisant l outil pour des travaux pour lesquels il a t concu 2 Cet outil a t concu pour une utilisation sp cifique Ne modifiez alt rez ni utilisez cet outil une fin autre que celle pour laquelle il a t concu 3 Tenez cet outil solidement des deux mains sauf s il est concu pour une utilisation avec une seule main L utilisation de l outil une seule main peut causer une perte de ma trise 4 Entretenez les outils avec soin consultez Entretien co N EEUU 6 Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 8347676 Multim tre num rique V 2 0 Retirez soigneusement les
12. 8347676 FIST Digital User Manual DIGITAL MULTIMETER o 200p 2000p A gt anm 20m 2003 Please read and understand all instructions before use Retain this manual for future reference V 2 0 8347676 SPECIFICATIONS DC Voltage Range 200m 2 000m 20 200 250V AC Voltage Range 200 250V DC Current Range 200uA 2000UA 20mA 200mA AC Current Range No Resistance 200 2 000 20k 200k 2 000k 20M Q Diode Test 2 8V 1mA Continuity Yes Decibels No LIQUID CRYSTAL DISPLAY LCD Display 3 1 2 digit LCD with max reading of 1999 Low Battery Indication shown on LCD Negative Polarity Indication Shown on LCD Overrange Indication 1 shown on the LCD DEVICE CAT Rating CAT 11 250V Automatic Power Off No Data Hold Function No Battery Test No Range Selection Manual Number of Functions Number of Ranges Sampling Rate Approx 3 times sec Battery Details 1 x 9V battery 6F22 or equivalent Fuse Yes Operation Temperature 0 C 40 C 75 RH Relative Humidity Storage Temperature 10 C 50 C lt 85 RH Relative Humidity Dimensions 128 x 66 x 26 mm Weight 5 Ibs 130g including battery For technical questions call 1 800 665 8685 V 2 0 Digital Multimeter 8347676 ELECTRICAL SYMBOLS Alternating Current Direct Current
13. Input Impedance 10MQ Max Permitted Input Voltage 250V DC AC rms MEASURING AC VOLTAGE CAUTION The Digital Multimeter is a CAT II device Measuring an AC Voltage that exceeds 250V rms will exceed the safety limits of the device and could result in an electric shock to the user or damage to the meter 1 Connect the black test lead to the COM Jack and the red test lead to V Jack 2 Set the range switch to desired AC range Y If the voltage to be measured is not known beforehand set the range switch to the highest range and then turn it down range by range until satisfactory resolution is obtained 3 Connect the test leads across the source or circuit to be measured 4 The LCD will display the reading AC VOLTAGE ACCURACY Range Resolution Accuracy 200V 100mV 1 2 10 250V 1V Frequency Range 40Hz 400Hz Overload Protection 250V rms Response Average calibrated in rms of sine wave DC CURRENT Connect the black test lead to COM Jack and n red test lead to mA Q Jack 2 Setthe range switch to desired DC current range if the current to be measured is not known beforehand set the range switch to the highest range and then turn it down range by range until satisfactory resolution is obtained Turn off power to the circuit that you want to measure and discharge all capacitors 4 Break the circuit path so the current cannot pass through the circuit Connect the test leads in series with the circui
14. ack and the red test lead to mA Q Jack 2 Set the range switch to the Diode position PT 3 Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode 4 The display will show the approximate forward voltage drop of the diode reading unit mV If the connection is reversed the number 1 will be shown on the display DIODE ACCURACY Range Description The approx forward voltage drop of the diode will be displayed Open Circuit Voltage about 2 8V Test current about 1mA CONTINUITY TEST NOTE Before performing a continuity test make sure that all power to the circuit has been turned off and all capacitors are fully discharged Continuity Test is a resistance test to determine if an electrical circuit is open or closed 1 Connect the black test lead to COM Jack and the red test lead to mA Q Jack 2 Set the range switch to the Continuity position a 3 Connect the test leads across the circuit to be measured 4 If the circuit resistance is less than about 30 Q the built in buzzer will sound CONTINUITY ACCURACY Range Description The built in buzzer will sound if the resistance is less than about 3092 Open Circuit Voltage about 2 8V MAINTENANCE Maintain the tool with care A tool in good condition is efficient easier to control and will prevent unnecessary problems 2 Follow instructions for lubricating and changing accessories 3 Inspect the t
15. d tool Examples are electrical non conductive clothes or clothes treated to resist corrosive liquids or materials 4 Foot Protection a Steel toe footwear or steel toe caps to prevent injury from falling objects b Non skid footwear is recommended to maintain footing and balance 5 Control the tool personal movement and the work environment to avoid personal injury or damage to tool Stay alert watch what you are doing and use your common sense a Keep articles of clothing jewelry hair etc away from moving parts to avoid entanglement with a tool b Do not operate any machine tool when tired or under the influence of drugs alcohol or medications c Do not overreach when operating a tool Proper footing and balance enables better control of a tool in unexpected situations SPECIFIC SAFETY PRECAUTIONS WARNING Use caution when working above 30V AC rms 42V peak or 60V DC Such voltages pose a shock hazard coco To avoid possible electric shock or personal injury follow these guidelines 1 Do not use the meter if it is damaged Before you use the meter inspect the case Pay particular attention to the insulation surrounding the connectors 2 Inspect the test leads for damaged insulation or exposed metal Check the test leads for continuity Replace damaged test leads before you use the meter 3 Do not use the meter if it malfunctions Protective features may be impaired When in doubt have the meter serviced 4 Do not operate th
16. e meter around explosive gas vapor or dust as an electric spark may cause the gas vapour or dust to ignite 5 Do not apply more than the rated voltage as marked on the meter between terminals or between any terminal and earth ground 6 When measuring current turn off power to the circuit before connecting the meter Remember to place the meter in series with the circuit When using the probes keep your fingers behind the finger guards on the probes Remove the test leads from the meter before you open the battery cover or the case Do not operate the meter with the battery cover or portions of the case removed or loosened To avoid false readings which could lead to possible electric shock or personal injury replace the battery as soon as the low battery indicator appears zip ce E For technical questions call 1 800 665 8685 5 V 2 0 Digital Multimeter 8347676 11 To avoid electric shock do not touch any naked conductor with your hand or skin Do not ground yourself while using the meter 12 Be aware that an input jack connected to a powered circuit may also create potential current at all other input jacks 13 CAT II Measurement Category Il is for measurements performed on circuits directly connected to low voltage installation Examples are measurements on household appliances portable tools and similar equipment Do not use the meter for measurements within Measurement Categories III and IV TOOL USE AND CARE Use
17. es instructions avant d utiliser cet outil L utilisateur doit respecter les pr cautions de base afin de r duire le risque de blessure et ou de dommage l quipement Avant de permettre une autre personne d utiliser cet outil assurez vous qu elle est au courant de toutes les consignes de s curit AVERTISSEMENT Les avertissements les attentions et les instructions mentionn s dans ce manuel d instructions ne peuvent couvrir toutes les conditions et situations pouvant se produire L op rateur doit faire preuve de bon sens et prendre toutes les pr cautions n cessaires afin d utiliser l outil en toute s curit REMARQUE Conservez ce manuel qui contient les avertissements de s curit les pr cautions les instructions de fonctionnement d inspection et d entretien 4 Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 8347676 Multim tre num rique V 2 0 ane DE TRAVAIL e Travaillez dans un environnement de travail s curitaire Gardez votre aire de travail propre et bien clair e N utilisez pas d outils lectriques en pr sence de gaz ou de liquides inflammables Assurez vous que les personnes qui ne portent pas l quipement de s curit appropri ne se trouvent pas proximit de l aire de travail Minimisez les distractions au sein de l environnement de travail Les distractions peuvent causer une perte de contr le de l outil Rangez les outils correctement dans un lieu s curis
18. id possible damage to the meter or to the equipment under test follow these guidelines 1 Disconnect circuit power and discharge all capacitors before testing resistance diode or continuity 2 Usethe proper terminals function and range for your measurements 3 Before measuring current check the meter s fuse and turn off the power to the circuit before connecting the meter to the circuit 4 Before rotating the rotary switch to change functions disconnect test leads from the circuit under test 5 Remove test leads from the meter before opening the meter case or the battery cover 6 Do not touch let the test leads touch each other during measurement as this may cause a short circuit acad eden Display The 3 5 digit LCD displays a max reading of 1999 a Function Range Switch This dial can be used to select the desired function and range as well as to turn the meter ON OFF Switch the dial to the OFF position when not in use This will extend the battery life 3 mA Q Jack Plug in connector for the red test lead This is used for testing Diode Continuity Resistance and Current measurements 4 COM Jack Plug in connector for the black Negative test lead 5 V Jack Plug in connector for the red test lead Used to test voltage measurements MEASUREMENT INSTRUCTIONS When making connections connect the common test lead before you connect the live test lead When you disconnect test leads disconnect the live test lead first
19. it relative Temp rature d entreposage 10 50 C 85 HR humidit relative Dimensions 128 x 66 x 26 mm Poids 130 g 0 5 Ib incluant la batterie Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 3 V 2 0 Multim tre num rique 8347676 SYMBOLES LECTRIQUES Courant alternatif Courant continu Attention risque de danger Reportez vous au manuel d utilisation avant l utilisation Attention risque de choc lectrique Borne de mise la terre masse Fusible Conforme aux directives de l Union Europ enne Le mat riel est entierement prot g par une double isolation ou une isolation renforc e ojama BR pli Cet instrument a subi des essais conform ment aux exigences de CAN CSA C22 2 n 61010 1 seconde dition y compris l amendement 1 ou une version ult rieure de la m me norme incorporant le m me niveau d exigences d essai INTRODUCTION Le multim tre est un appareil num rique compact avec affichage de 3 1 2 chiffres pour mesurer la tension c c et C a le courant c c la r sistance la temp rature la diode et la continuit S CURIT Ce multim tre a t con u conform ment la norme IEC 61010 sur les instruments de mesure lectroniques de la cat gorie de mesure CAT 11 250 V et du niveau de pollution 2 CONSIGNES DE SECURITE IMPORTANTES AVERTISSEMENT Lisez et assurez vous de comprendre toutes l
20. le un centre de recyclage appropri Apportez l outil au magasin Princess Auto Ltd le plus pr s pour des r parations Si ce n est pas possible demandez un technicien qualifi de r parer l outil 12 Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685
21. nal tique demeurent intactes sur l outil Elles comportent des renseignements importants Si elles sont illisibles ou manquantes communiquez avec Princess Auto Ltd pour les remplacer ATTENTION Seul un personnel d entretien qualifi doit effectuer la r paration de l outil D Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 11 V 2 0 Multim tre num rique 8347676 REMPLACEMENTS DE LA PILE ET DU FUSIBLE Lorsque le symbole EA apparait l cran la pile est faible et devrait tre remplac e Pour remplacer la pile 1 Retirez la vis sur le boitier de la pile et d posez le couvercle 2 Remplacez la pile vide par une nouvelle pile du m me type 9 V 6F22 ou l quivalent 3 Remettez en place le couvercle de la pile et la vis Le fusible a rarement besoin d tre remplac moins qu il ne soit saut en raison d une erreur de l op rateur Pour remplacer le fusible 1 D vissez et retirez le couvercle de la pile 2 Retirez les vis sur le couvercle arri re et d posez le couvercle arri re 3 Remplacez le fusible saut par un nouveau fusible du m me calibre a Cemultim tre fait appel un fusible tube de c ramique unique 250 mA 250 V action rapide o 5x20mm 4 Remettez en place le couvercle arri re et ses vis 5 Remettez en place le couvercle de la pile et sa vis MISE AU REBUT DE L OUTIL Si votre outil est trop endommag pour tre r par ne le jetez pas Apportez
22. ommag ou si le m tal est expos sur les fils d essai V rifiez la continuit des fils d essai Remplacez les fils d essai endommag s avant d utiliser le multim tre 3 N utilisez pas le multim tre en cas de d faillance Les caract ristiques de protection peuvent tre diminu es En cas de doute faites v rifier le multim tre 4 Ne faites pas fonctionner le multim tre en pr sence de poussi res de vapeurs ou de gaz explosifs puisqu une tincelle lectrique peut avoir pour effet d allumer le gaz les vapeurs ou la poussi re 5 N utilisez pas une tension sup rieure la tension nominale entre les bornes ou entre une borne et la masse comme il est indiqu sur le multim tre 6 Lorsque vous mesurez le courant coupez l alimentation du circuit avant de brancher le multim tre N oubliez pas de brancher le multim tre en s rie avec le circuit Lorsque vous utilisez les sondes gardez vos doigts derri re les prot ge doigts sur les sondes Enlevez les fils d essai du multim tre avant d ouvrir le couvercle de piles ou le boitier 9 Ne faites pas fonctionner le multim tre si le couvercle de piles ou des parties du boitier ont t enlev s ou desserr s 10 Pour viter d obtenir des lectures erron es pouvant causer des chocs lectriques ou des blessures remplacez la pile d s que l indicateur de pile faible apparait 11 Pour viter les chocs lectriques ne touchez pas aux conducteurs nus avec votre main ou la peau Ne
23. ool fittings periodically Have damaged or worn components repaired or replaced by an authorized technician 4 Maintain the tool s label and name plate These carry important information If unreadable or missing contact Princess Auto Ltd for replacements CAUTION Only qualified service personnel should repair the tool FE LL LL o ue e M 10 For technical questions call 1 800 665 8685 8347676 Digital Multimeter V 2 0 BATTERY AND FUSE REPLACEMENTS When the symbol appears on the display the battery is low and should be replaced To replace the battery 1 Remove the screw on the battery cover and remove the battery cover 2 Replace the exhausted battery with a new one of the same type 9V 6F22 or equivalent 3 Reinstall the battery cover and the screw To replace the fuse 1 Unscrew and remove the battery cover 2 Remove the screws on the back cover and remove the back cover 3 Replace the blown fuse with a new one of the same rating a This meter uses a single ceramic tube fuse 250mA 250V Fast Action 5 x 20 mm 4 Reinstall the back cover and its screws 5 Reinstall the battery cover and its screw DISPOSING OF TOOL If your tool has become damaged beyond repair do not throw it out Bring it to the appropriate recycling facility TROUBLE SHOOTING Bring the tool to the nearest Princess Auto Ltd for repairs If unable to do so have a qualified technician service the tool For technical que
24. our viter les blessures dues la chute d objets b Les chaussures antid rapantes sont recommand es pour maintenir la stabilit et l quilibre Gardez le contr le de l outil de vos mouvements et de l environnement de travail pour viter les blessures ou le bris de l outil Restez alerte portez attention vos gestes et faites preuve de bon sens a Tenez les v tements les bijoux les cheveux etc l cart des pi ces mobiles pour viter de les faire coincer par l outil b N utilisez pas d appareils ou d outils si vous tes fatigu ou sous l effet de drogues d alcool ou de m dicaments c N utilisez pas l outil si vous devez tirer les bras pour le faire Une stabilit et un quilibre appropri s sont n cessaires afin d avoir un meilleur contr le de l outil en cas de situations inattendues Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 5 V 2 0 Multim tre num rique 8347676 CONSIGNES DE S CURIT SP CIFIQUES AVERTISSEMENT Soyez prudent lorsque vous travaillez dans des conditions qui d passent 30 V c a rms 42 V de pointe ou 60 V c c De telles tensions constituent un risque de choc Pour viter les chocs lectriques ou les blessures suivez ces directives 1 N utilisez pas le multim tre s il est endommag Avant d utiliser le multim tre v rifiez le boitier Soyez particuli rement attentif l isolant autour des connecteurs 2 V rifiez si l isolant est end
25. rcuit avant de brancher le multim tre au circuit 4 Avant de tourner le commutateur rotatif pour changer les fonctions d branchez les fils d essai du circuit mesurer Enlevez les fils d essai du multim tre avant d ouvrir le boitier du multim tre ou le couvercle de piles 6 Ne touchez pas les fils d essai ensemble lors du mesurage puisqu il peut en r sulter un court circuit en Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 7 V 2 0 Multim tre num rique 8347676 MULTIMETER 1 Affichage LACL a 3 5 chiffres affiche une lecture max de 1 999 2 S lecteur de fonction plage Ce cadran peut tre utilis pour s lectionner la 1 fonction et la plage souhait es ainsi que pour placer le multim tre sous et hors tension Placez le cadran la position d arr t OFF lorsqu il n est pas utilis Cela aura pour effet de prolonger la dur e de vie de la batterie 3 Prise mA Q Branchez le connecteur pour le fil d essai rouge Cet appareil 2 permet de mesurer la diode la continuit la r sistance et le courant 4 Prise COM Branchez le connecteur pour le fil d essai noir n gatif 5 Prise V Branchez le connecteur pour le fil d essai rouge Utilis pour v rifier la tension d essai INSTRUCTIONS DE MESURE Lorsque vous effectuez des connexions branchez le fil d essai neutre avant de brancher le fil d essai sous tension Lorsque vous d branchez les fils d essai d branchez le
26. s d onde sinusoidale kis DE COURANT C C Branchez le fil d essai noir sur la prise COM et le fil d essai Pas sur la prise mA Q R giez le s lecteur de plage la plage de courant c c d sir e Si le courant mesurer n est pas connue d avance s lectionnez d abord la plage la plus lev e du s lecteur de plage puis r duisez progressivement la plage suivante jusqu l obtention d une r solution satisfaisante Coupez l alimentation sur le circuit que vous voulez mesurer et d chargez tous les condensateurs Interrompez le trajet du circuit de facon emp cher le courant de passer au travers du circuit Branchez les fils d essai en s rie sur le circuit Mettez le circuit sous tension et lisez les indications sur l afficheur La polarit de la connexion du fil d essai rouge sera galement indiqu e Si vous avez des questions de nature technique veuillez appeler le 1 800 665 8685 9 V 2 0 EXACTITUDE DU COURANT C C Multim tre num rique Plage R solution Exactitude 200 pA 0 1 uA 1 0 4 5 2 000 uA 1 VA 20 mA 10 pA 200 mA 100 LA 1 2 4 5 Protection contre les surcharges Fusible tube de c ramique 250 mA 250 V action rapide Chute max de la tension d essai 200 pV MESURER LA R SISTANCE REMARQUE Avant de mesurer la r sistance l int rieur du circuit assurez vous que tout le courant alimentant le circuit est enti rement coup et que tous les condensateurs
27. stions call 1 800 665 8685 11 V 2 0 Digital Multimeter 8347676 Co el 12 For technical questions call 1 800 665 8685 V 2 0 8347676 Manuel du Propri taire DIGITAL MULTIMETER 519 35 200m 20 m 900 mA Q CY FUSED CAT 111 250 Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard V 2 0 8347676 SP CIFICATIONS Plage de tension c c 200m 2 000m 20 200 250V Plage de tension c a 200 250V Plage de courant c c 200 uA 2 000 uA 20 mA 200 mA Plage de courant c a Non R sistance 200 2 000 20 000 200 000 2 millions 20 millions Q V rification de la diode 2 8V 1mA Continuit Oui D cibels Non AFFICHAGE CRISTAUX LIQUIDES ACL Affichage ACL de 3 1 2 chiffres avec lecture max de 1 999 Affichage de pile faible affich sur ACL Affichage de polarit n gative affich sur ACL Indication de d passement de plage 1 affich sur ACL DISPOSITIF Niveau CAT CAT 11 250 V Arr t automatique Non Fonction de m morisation des donn es Non V rification de batterie Non S lection de plage Manuel Nombre de fonctions 6 Nombre de plages 19 Fr quence d chantillonnage Environ 3 fois sec D tails de la pile 1 pile de 9 V 6F22 ou l quivalent Fusible Oui Temp rature de fonctionnement 0 40 C 75 HR humid
28. t 5 Turn on power to the circuit then read the display The polarity of the red test lead connection will be indicated pe FS 8 For technical questions call 1 800 665 8685 8347676 Digital Multimeter V 2 0 DC CURRENT ACCURACY Range Resolution Accuracy 2004A 0 1pA 1 0 5 2000gA 1pA 20mA 10uA 200mA 100A 1 2 5 Overload Protection Ceramic Tube Fuse 250mA 250V Fast Action Max Test Voltage Drop 200mV MEASURING RESISTANCE NOTE Before measuring in circuit resistance make sure that all power to the circuit has been turned off and all capacitors are fully discharged 1 Connect the black test lead to COM Jack and the red test lead to mA Q Jack 2 Set the range switch to desired Q range 3 Connect the test leads across the load to be measured 4 Read the reading on the display The multimeter may take longer to stabilize a reading when the resistance measurement is gt 1 MQ This is normal for high resistance measurements 1 is displayed as an overrange indication when the input is not connected RESISTANCE ACCURACY Range Resolution Accuracy 20092 0 100 1 0 5 2 000Q 1Q 0 8 5 20kQ 100 200kQ 1002 2 000kQ 1kQ 1 2 5 20MQ 10kQ 1 2 10 Max Open Circuit Voltage approx 2 8V For technical questions call 1 800 665 8685 9 V 2 0 Digital Multimeter 8347676 MEASURING DIODE 1 Connect the black test lead to COM J

Download Pdf Manuals

image

Related Search

Related Contents

ボイストレックVN  取扱説明書    Kenmore 790.479 User's Manual  SERVICE MANUAL R-2275 R-2285  Altronix AL802ULADAJ power extension  GT863-PY Harware User Guide  Rexel Standard L Folders  Magnetismo Curativo - Cultura Espírita Jaú    

Copyright © All rights reserved.
Failed to retrieve file