1. Bottom Trim Screws supplied Figure 6 Figure 7 MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS 5 Leveling the Wall Oven 1 2 Install an oven rack in the center of the upper oven see Figure 8 Place a level on the rack Take 2 readings with the level placed diagonally in one direction and then the other Use wood shims under the wall oven to level if necessary Figure 8 IMPORTANT NOTE A cooling fan inside the upper rear part above the oven some models provides cooling of the oven electrical and electronic components If the oven has been operating at high temperatures the fan will continue to run after the oven is turned off 7 Checking Operation Your model is equipped with an Electronic Oven Control Each of the functions has been factory checked before shipping However it is suggested that you verify the operation of the electronic oven controls once more Refer to the Use and Care Guide for operation _ Remove all items from the inside of the oven 2 Turn on the power to the oven Refer to your Use amp Care Guide 3 Verify the operation of the electronic oven controls Bake Verify that this function makes the oven hot 20 seconds after turning oven on open the door and you should feel heat coming from the oven Broil When the oven is set to BROIL the upper element in the oven should become red Bef
2. Partie 1 au Canada Grimper s appuyer ou s asseoir sur la porte de ce four encastr peut entra ner des blessures graves et peut aussi causer des dommages au four encastr N utilisez jamais votre four encastr pour chauffer ou r chauffer la pi ce L utilisation prolong e du four encastr sans ventilation ad quate peut tre dangereuse Il faut couper l alimentation TEETE durant le montage des connexions lectriques d faut de ce faire il peut en r sulter des blessures graves ou la mort 1 Travaux de menuiserie Reportez vous la page 1 pour tablir quelles sont les dimensions applicables votre mod le ainsi que l espace n cessaire pour recevoir l appareil La surface qui supporte l appareil doit tre en contre plaqu solide ou tout autre mat riau du m me type Il faut vous assurer que la surface est de niveau d un c t l autre et de l avant l arri re 2 Exigences lectriques Cet appareil doit tre branch une alimentation poss dant la tension et la fr quence appropri es Il doit tre connect un circuit d di correctement mis la terre et prot g par un disjoncteur ou un fusible Pour savoir quel disjoncteur ou fusible utiliser avec cet appareil r f rez vous la plaque signal tique pour conna tre la consommation watts et avec cette donn e consultez la table A pour conna tre l amp rage requis du disjoncteur ou du fusible Calibre de Circuit de Calibre de C
3. grounded by connection of grounding lead to neutral lead at the termination of the conduit if used in USA in a new branch circuit installation 1996 NEC mobile home recreational vehicles where local code do not permit grounding trough the neutral white wire or in Canada disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch circuit neutral conductor in usual manner see Figure 4 If your appliance is to be connected to a 3 wire grounded junction box US only where local code permit connecting the appliance grounding conductor to the neutral white see Figure 3 NOTE TO ELECTRICIAN The armored cable leads supplied with the appliance are UL recognized for connection to larger gauge household wiring The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire rather than the wire gauge alone Where local codes permit connecting the appliance grounding conductor to the neutral white wire ge Only see figure 3 Disconnect the power supply gt In the junction box ee appliance and power supply cable wires as shown in Figure 3 Cable from Power Supply White Wire Neutral Red Junction Box White Wire Neutral U L Listed
4. 1 en laissant autant de l che que possible dans le c ble entre la bo te et l appareil pour en faciliter le d placement si l entretien s av re n cessaire 3 Une attache de protection s curitaire doit retenir le c ble arm flexible la bo te de jonction INSTRUCTIONS D INSTALLATION POUR LE MODELE COMBINE FOUR A ENCASTRER FOUR A MICRO ONDES AVERTISSEMENT Risque de choc lectrique e La mise la terre de cet appareil est obligatoire e Ne branchez pas l appareil au circuit lectrique tant qu il ne sera pas mis la terre correctement et en permanence Coupez l alimentation la bo te de jonction avant de faire les raccords lectriques Cet appareil doit tre connect un circuit permanent lectrique m tallique et mis la terre ou un connecteur de mise la terre qui doit tre branch la borne ou au fil de mise la terre de l appareil N utilisez pas un tuyau d alimentation de gaz pour la mise la terre de l appareil Si vous ne respectez pas toutes les instructions pr c dentes un feu des blessures corporelles ou un choc lectrique peuvent en r sulter Par temps froid pour prot ger la commande du four il faut attendre au moins trois 3 heures la temp rature de la pi ce avant de mettre l appareil sous tension Ceci vitera toute possibilit d endommager la commande du four lors de la mise sous tension 3 Connexions lectriques Le consommateu
5. 68 9 Min Four encastr 30 76 2cm 28 72 4 29 73 7 23 59 7 41 s 104 5 41 104 8 30 s 76 5 Min Toutes les dimensions sont en pouces cm Imprim aux tats Unis P N 318201534 0905 Rev A INSTRUCTIONS D INSTALLATION POUR LE MODELE COMBINE FOUR A ENCASTRER FOUR A MICRO ONDES Notes importantes pour l installateur 1 Lisez toutes les instructions contenues dans ce feuillet avant l installation du four encastr 2 Enlevez tout le mat riel d emballage du four avant de proc der au raccordement lectrique 3 Observez tous les codes et r glements applicables 4 Assurez vous de laisser ces instructions au consommateur 5 La porte du four peut tre enlev e pour faciliter l installation 6 CE FOUR N EST PAS HOMOLOGU POUR UNE INSTALLATION C TE C TE OU SUPERPOSEE Consommateur Conservez ces instructions avec votre Manuel d utilisation et d entretien pour l inspecteur d lectricit local et r f rences futures DIRECTIVES IMPORTANTES DE SECURITE e Assurez vous que votre four encastr est install et mis la terre conform ment par un installateur ou un technicien de service qualifi e Ce four encastr doit tre mis la terre conform ment aux codes locaux d lectricit ou en l absence de codes en conformit avec le National Electrical Code ANSI NFA No 70 derni re dition aux tats Unis ou avec la norme ACNOR C22 1
6. Conduit Connector or CSA listed Ground Wire Bare or Green Wire Cable from appliance Figure 3 3 WIRE GROUNDED JUNCTION BOX MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS if oven is used in a new branch circuit installation 1996 NEC mobile home recreational vehicle or where local codes DO NOT permit grounding through the neutral white wire the appliance frame MUST NOT be connected to the neutral wire of the 4 wire electrical system see figure 4 1 Disconnect the power supply 2 Separate the green or bare copper and white appliance cable wires 3 In the junction box connect appliance and power supply cable wires as shown in Figure 4 Cable from Power Supply Ground Wire Red Wires White Wire N__U_L Listed Conduit Connector or CSA listed Wire Junction Box ee Cable from appliance Figure 4 4 WIRE GROUNDED JUNCTION BOX Model and Serial Number Location The serial plate is located along the interior side trim of the oven and visible when the door is opened When ordering parts for or making inquires about your oven always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your oven Serial Plate Location 4 Cabinet Installation IMPORTANT NOTE Do not lift the oven by the door handle WARNING Heavy Weight Hazard e Use 2 or
7. MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER Canada IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE 4 MUANI For YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance United States Your new wall oven has been designed to fit a limited variety of cutout sizes to make the job of installing easier The first step of your installation should be to measure your current cutout dimensions and compare them to the cutout dimensions chart below for your UL model You may find little or no cabinet work is necessary A WARNING Do not remove spacers if equipped on the side walls and or on the back of the built in oven These spacers center the oven in the space provided The oven must be centered to prevent excess heat buildup that may result in heat damage or fire NOTES Hole for 1 Base must be capable of supporting 225 pounds 102 kg i Cable 2 Allow at least 21 53 3cm clearance in front of oven for door 1 2 5 cm 2 right or depth when it is open Min left side 3 Dimension G cutout depth is re depending critical to the proper installation f on model of the built in oven If the gt oven decorative trim
8. all governing codes and ordinances Be sure to leave these instructions with the consumer Oven door may be removed to facilitate installation THIS COMBINATION OVEN IS NOT APPROVED FOR STACKABLE OR SIDE BY SIDE INSTALLATION On Oe important Note to the Consumer Keep these instructions with your Owner s Guide for future reference Do not discard oven removal tools found in the literature bag IMPORTANT SAFETY INSTRUCTIONS Be sure your combination oven is installed and grounded properly by a qualified installer or service technician e This wall oven must be electrically grounded in accordance with local codes or in their absence with the National Electrical Code ANSI NFPA No 70 latest edition in United Sates or with CSA Standard C22 1 Canadian Electrical Code Part 1 in Canada ONIN Stepping leaning or sitting on the door of this wall oven can result in serious injuries and can also cause damage to the wall oven Never use your wall oven for warming or heating the room Prolonged use of the wall oven without adequate ventilation can be dangerous H AR The electrical power to the oven must be shut off while line connections are being made Failure to do so could result in serious injury or death 1 Carpentry Refer to page 1 for the dimensions applicable to your appliance and the space necessary to receive the combination oven The oven support surface may be solid plywood or similar
9. d un conducteur blanc neutre Cet appareil est fabriqu avec un c ble d alimentation muni d un fil blanc neutre et d un fil de mise la terre en cuivre branch sur le ch ssis Si l appareil est utilis aux tats Unis dans une maison mobile un nouveau branchement 1996 NEC un v hicule r cr atif o les codes locaux n autorisent pas la connexion du conducteur de mise la terre du ch ssis au neutre ou au Canada d branchez les fils blanc et vert des autres et utilisez le fil de mise la terre pour mettre la terre l appareil conform ment aux codes locaux branchez le conducteur neutre de mani re habituelle au circuit neutre voir la figure 4 Si l appareil doit tre branch un c ble 3 fils aux tats Unis seulement o les codes locaux permettent la connexion du fil de mise la terre du ch ssis au neutre blanc Voir la figure 3 LECTRICIEN Le c ble gain fourni avec cet appareil est homologu par UL pour connexion des circuits r sidentiels de fils de calibre sup rieur La capacit thermique de l isolant des c bles exc de consid rablement celle des circuits r sidentiels La transmission du courant lectrique maximum permise des fils du c ble est en fonction de la capacit thermique de la gaine plut t que du calibre du fil Si les codes locaux permettent la connexion du fil de mise la terre du ch ssis au neutre blanc aux tats Unis seulement voir figure 3 1 Coupez l a
10. does not pees butt against the cabinet verify Be dimension G to assure it is the gt F required depth ie 40 15 16 104 cm NY Wh 3 7 6 cm D Goon 29 2 cm Max oor Open ga de i Electrical see note 2 Junction Box right or left side Suggested distance from floor is 11 29 2cm Minimum required distance is 2 5 cm Wide Wood Spacer if Needed Figure 1 4 2 11 4cm PRODUCT DIMENSIONS MODEL A B 27 68 6cm Wall Oven 27 68 6 4234 108 6 24 62 5 24 62 2 30 76 2cm Wall Oven 30 76 2 4234 108 6 28 71 8 24 62 2 CUTOUT DIMENSIONS AND CABINET WIDTH F H MODEL Min Max G Min Min Max I 27 68 6cm Wall Oven 24 3 63 2 25 64 1 23 59 7 41 104 5 41 104 8 27 2 68 9 Min 30 76 2cm Wall Oven 28 72 4 29 73 7 23 59 7 41 104 5 41 104 8 30 s 76 5 Min All dimensions are stated in inches and cm Printed in United States P N 318201534 0905 Rev A MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS important Notes to the Installer 1 Read all instructions contained in these installation instructions before installing the combination oven 2 Remove all packing material from the oven compartments before connecting the electrical supply to the wall oven Observe
11. e four doit tre centr pour pr venir une accumulation excessive de chaleur pouvant causer un feu ou des dommages NOTES Ouverture 1 La base doit pouvoir supporter 225 lbs 102 kg i pour la 2 Allouez au moins 21 53 3 cm d espace l avant du four pour 1 2 5 cm be sortie du permettre l ouverture compl te de la porte du four Mi 7 as a 3 La dimension G profondeur du LT ee d coupage est critique pour une ice salons bonne installation du four Si la gt mod le pas s accoter contre l armoire ou Be 4 si un bruit se fait entendre sur les ew F mod les convection v rifiez la N 40 15 16 dimension G pour vous assurer S 104 cm qu elle est correcte x 11 3 7 6 cm ae a 29 2 cm Max orte ouverte voir note 2 ee Entretoise Ss Buitede i Entretoise de bois de 2 ee 5 cm de largeur si Aie ous La distance sugg r e du plancher est 11 29 2 cm Figure PASEAR E gauche La distance minimale requise est 41 11 4 cm DIMENSIONS DE L APPAREIL MOD LE A B Four encastr 27 68 6cm 27 68 6 4234 108 6 24 62 5 24 62 2 Four encastr 30 76 2cm 30 76 2 4234 108 6 28 71 8 2412 62 2 DIMENSIONS DE D COUPAGE ET DE L ARMOIRE F H MOD LE Min Max G Min Min Max I Four encastr 27 68 6cm 24 63 2 25 64 1 23 59 7 41 3 104 5 41 104 8 27
12. ectroniques internes froides Il est donc possible que la soufflerie continue de fonctionner m me apr s l arr t de l appareil et ce jusqu ce que les composantes aient refroidi 7 V rification du fonctionnement Si votre appareil poss de une commande lectronique de four Toutes les fonctions qu elle contr le ont t v rifi es en usine pour leur bon fonctionnement avant que l appareil soit exp di Cependant nous vous sugg rons de v rifier nouveau le fonctionnement de la commande lectrique Reportez vous votre Manuel d utilisation et d entretien pour le r glage du four 1 Retirer tous les items du four avant de proc der la v rification 2 Mettre l appareil sous tension 3 V rifier les op rations de la commande lectronique Cuisson V rifier que lorsque le four est en fonction cuisson l l ment de cuisson chauffe 20 secondes apr s avoir programm le four en mode cuisson si en ouvrant la porte vous sentez de la chaleur s chapper du four c est qu il fonctionne Grillage L l ment du haut rougit lorsque le four est r gl pour le mode grillage Avant d appeler le service d entretien R viser la liste de v rifications pr ventives et les instructions d op ration dans votre Manuel d utilisation et d entretien Vous sauverez probablement du temps et de l argent La liste contient les incidents ordinaires ne r sultant pas de d fectuosit s dans le mat riel ou la fabrication de ce
13. eed a longer power cord you can purchase a 10 3 m power cord kit 903056 9010 by calling the Service Center 2 These appliances should be connected to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed cable The flexible armored cable extending from the appliance should be connected directly to the junction box The junction box should be located as shown in Figure 1 and with as much slack as possible remaining in the cable between the box and the appliance so it can be moved if servicing is ever necessary 3 A suitable strain relief must be provided to attach the flexible armored cable to the junction box MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS amp WARNING Electrical Shock Hazard Electrical ground is required on this appliance Do not connect to the electrical supply until appliance is permanently grounded Disconnect power to the junction box before making the electrical connection This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the grounding terminal or wire lead on the appliance e Do not use a gas supply line for grounding the appliance Failure to do any of the above could result in a fire personal injury or electrical shock PIN In cold weather shipping and storage conditions make sure that oven is in final location at least three 3 hours before switch
14. ing on power Switching on power while oven is still cold may damage the oven controls 3 Electrical connection It is the responsibility and obligation of the consumer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA Standard C22 1 Canadian Electrical Code Part 1 and local codes and ordinances PNW Risk of electrical shock Failure to heed this warning may result in electrocution or other serious injury This appliance is equipped with copper lead wire If connection is made to aluminum house wiring use only connectors that are approved for joining copper and aluminum wire in accordance with the National Electrical Code and local code and ordinances When installing connectors having screws which bear directly on the steel and or aluminum flexible conduit do no tighten screws sufficiently to damage the flexible conduit Do not over bend or excessively distort flexible conduit to avoid separation of convolutions en exposure of internal wires DO NOT ground to a gas supply pipe DO NOT connect to electrical power supply until appliance is permanently grounded Connect the ground wire before turning on the power If your appliance is equipped with a white neutral conductor This appliance is manufactured with a white neutral power supply and a frame connected copper wire The frame is
15. ircuit de l appareil Watts protection l appareil Watts protection 240V recommand 208V recommand Masoom zoow soa f aoon ezon 308 ME EE ME owe soa mue Table A Observez tous les r glements et les codes locaux applicables Un c ble lectrique 3 ou 4 fils de 120 240 ou 120 208 Volt monophas 60 Hz CA est requis sur un circuit s par muni d un fusible sur chaque fil conducteur fusible temporis o disjoncteur recommand NE RELIEZ PAS de fusible au neutre NOTE Le calibre des fils et leurs connexions doivent tre conformes la capacit des fusibles et la capacit nominale de l appareil selon le National Electrical Code ANSI NFPA No 70 derni re dition ou selon la norme ACNOR C22 1 Partie 1 du Code canadien de l lectricit et les codes et les r glements locaux ENNEMI N utilisez pas de rallonge lectrique avec ces appareils Son utilisation peut causer un feu un choc lectrique ou des blessures corporelles Si un c ble d alimentation plus long est requis vous pouvez vous en procurer un de 10 3 m en t l phonant au centre de service et en demandant le kit 903056 9010 2 I faut brancher l appareil au panneau de distribution en utilisant des c bles flexibles gaine m tallique ou non m tallique On doit brancher directement la bo te de jonction le c ble gain flexible de l appareil Il faut disposer la bo te de jonction tel qu illustr la Figure
16. la moulure inf rieure Le four encastr peut basculer Placez le haut de la moulure inf rieure par dessus les quand la porte est ouverte Il faut fixer l appareil petites languettes de chaque c t du four encastr l armoire a l aide des vis de fixation fournis pour sous la porte Vissez la moulure dans les trous situ s pr venir le basculement du four et des blessures de chaque c t de l appareil en utilisant les vis corporelles fournies avec la moulure voir la figure 7 A Les vis situ es sur les moulures lat rales peuvent servir de gabarit voir la figure 6 B Utilisez les deux vis fournies pour fixer l appareil l armoire Moulure inf rieure Vis fournies Figure 6 Figure 7 INSTRUCTIONS D INSTALLATION POUR LE MODELE COMBINE FOUR A ENCASTRER FOUR A MICRO ONDES 5 Mise a niveau du four encastr 1 Installez une grille au centre du four sup rieur Voir la figure 8 2 D posez un niveau a bulle sur la grille Prenez 2 lectures en placant le niveau en diagonale dans une direction puis dans l autre direction Utilisez des entretoises de bois sous le four encastr pour niveler si n cessaire i i Hi tid Hil i j Figure 8 NOTE IMPORTANTE Une soufflerie situ e dans la partie interne sup rieure a l arri re de l appareil permet de garder les composantes lectriques et l
17. limentation la bo te de jonction 2 Dans la bo te de jonction Raccordez les fils de l appareil ceux du circuit lectrique tel que montr la figure 3 C ble d alimentation Fil d nud Fils rouges Bo te de jonction Fil blanc Connecteur homologu U L ou ACNOR Fil d nud ou vert C ble de l appareil Figure 3 BO TE DE JONCTION 3 FILS MISE LA TERRE INSTRUCTIONS D INSTALLATION POUR LE MODELE COMBINE FOUR A ENCASTRER FOUR A MICRO ONDES Si l appareil est utilis dans une maison mobile un nouveau branchement 1996 NEC un v hicule r cr atif ou si les codes locaux N AUTORISENT PAS la connexion du conducteur de mise la terre du ch ssis au neutre le ch ssis de l appareil NE DOIT PAS tre branch au fil neutre du c ble 4 fils voir le figure 4 1 Coupez l alimentation la bo te de jonction 2 S parez le fil blanc du fil d nud en cuivre de mise la terre du c ble d alimentation de l appareil 3 Dans la bo te de jonction Raccordez les fils de l appareil ceux du circuit lectrique tel que montr la figure 4 C ble d alimentation Fil d nud Fil blanc Fils rouges Fils noirs Fil d nud oN ou vert Fil blanc Botte de onnecteur jonction ss homologu U L Cable de l appareil ou ACNOR Figure 4 BO TE DE JONCTION 4 FILS MISE LA TERRE Emplacement des num ros de mod le e
18. material however the surface must be leveled from side to side and from front to rear 2 Electrical Requirements This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse To know the circuit breaker or fuse required by your model see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage Appliance Protection Appliance Rating Watts Circuit Rating Watts 240V Recommended 208V Less than 4800W han 4100W 4800W 7200W 4100W 6200W 7200W 9600W 6200W 8300W 9600W and 8300W and Table A Observe all governing codes and local ordinances 1 A 3 wire or 4 wire single phase 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line red and black wires A time delay fuse or circuit breaker is recommended DO NOT fuse neutral white wire NOTE Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the American National Electrical Code ANSI NFPA No 70 latest edition or with Canadian CSA Standard C22 1 Canadian Electrical Code Part 1 and local codes and ordinances ENT An extension cord should not be used with this appliance Such use may result in a fire electrical shock or other personal injury If you n
19. more people to move and install wall oven e Failure to follow this instruction can result in injury or damage to the unit Unpack the wall oven Remove the bottom trim taped on the oven side panel Find the 2 anti tip mounting screws included in the literature package Insert the oven into the cabinet opening Slide oven inward leaving 1 3 8 cm clearance between the oven and front of cabinet see Figure 5 Pull the armored cable through the hole for it in the cabinet and toward the junction box while moving the appliance inward O Push the oven in and against the cabinet 1 3 8 cm clearance between unit Figure 5 MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS install the Anti tip Mounting Screws 7 Install the Bottom Trim The wall oven can tip when the door Place the top of the bottom trim over the side trim is open The anti tip mounting screws supplied tabs on each side of the oven below the oven door with the wall oven must be installed to prevent and fix it using the 2 screws supplied in the mounting tipping of the wall oven and injury to persons holes located on each side trim below the oven frame A The mounting holes in the side trims may be used see Figure 7 as a template to locate the appliance mounting screw holes see figure 6 B Use the two screws supplied to fix the appliance to the cabinet
20. ore You Call for Service Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to your Use and Care Guide for service phone numbers INSTRUCTIONS D INSTALLATION POUR LE MODELE COMBINE FOUR A ENCASTRER FOUR A MICRO ONDES L INSTALLATION ET L ENTRETIEN DOIVENT ETRE EFFECTU S PAR UN Pai INSTALLATEUR QUALIFI _ IMPORTANT CONSERVEZ POUR L INSPECTEUR D LECTRICIT LOCAL LISEZ ET CONSERVEZ CES INSTRUCTIONS POUR R F RENCES ULT RIEURES 4 INTER POUR VOTRE S CURIT N entreposez pas ou n utilisez pas d essence ou d autres produits inflammables proximit de cet appareil ou de tout autre appareil lectrom nager tats Unis Votre nouveau four encastr a t con u pour s ajuster diff rentes dimensions de d coupage et en faciliter l installation La premi re tape de votre installation consiste U mesurer les dimensions du d coupage actuel et les comparer au tableau de dimensions L de d coupage ci dessous Vous d couvrirez peut tre que peu ou pas de modification sera n cessaire N enlevez pas les entretoises s il y en a sur les parois lat rales et ou l arri re du four Ces entretoises centrent le four dans l espace fourni L
21. r est responsable et doit communiquer avec un installateur qualifi pour s assurer que l installation lectrique est ad quate et conforme avec le National Electrical Code ANSI NFPA No 70 derni re dition ou avec la norme ACNOR C22 1 partie 1 du code canadien de l lectricit et les codes et r glements locaux Risque de choc lectrique Si cet avertissement n est pas pris en consid ration un choc lectrique ou des blessures s rieuses peuvent survenir Cet appareil est muni de fils en cuivre Si ce dernier est branch circuit r sidentiel en aluminium n utilisez que des connecteurs qui sont approuv s pour joindre des fils de cuivre des fils d aluminium conform ment au National Electrical Code et les codes et r glements locaux Lors de l installation des connecteurs munis de vis touchant directement l acier ou l aluminium de conduit flexible il ne faut pas serrer celles ci outre mesure afin d viter d endommager le conduit flexible Il ne faut ni plier ni tordre outre mesure un conduit flexible de mani re viter un bris dans la gaine et une exposition des fils ou c bles internes NE connectez pas le fil de mise la terre un tuyau d alimentation de gaz Ne branchez pas l appareil au circuit lectrique avant qu il soit mis la terre correctement en permanence Branchez le conducteur de mise la terre avant de mettre l appareil sous tension Si votre appareil poss de un c ble muni
22. t appareil Pour obtenir notre adresse et notre num ro de t l phone sans frais r f rez vous votre Manuel d utilisation et d entretien
23. t de s rie La plaque signal tique est situ e sur le c t int rieur de la moulure lat rale Pour toute commande de pi ces ou demande de renseignement au sujet de votre appareil assurez vous d inclure les num ros de mod le et de s rie ainsi que le num ro ou lettre de lot de la plaque signal tique de votre four Serial Plate Location 4 Cabinet Installation PORIA Ne soulevez pas l appareil par la poign e de la porte AVERTISSEMENT Risque de lourde charge Soyez 2 personnes ou plus pour installer ou d placer l appareil e Des blessures ou des dommages l appareil peuvent survenir si vous ne suivez pas cette instruction D ballez le four encastr et r cup rez la moulure inf rieure qui est fix e sur le c t du four 2 Localisez les vis de fixation qui se trouvent dans l enveloppe litt rature Ins rez l appareil dans le d coupage de l armoire Glissez l unit vers l int rieur en laissant un espace de 1 3 8 cm entre le four et le devant de l armoire voir figure 5 Tirez le c ble gain travers le trou du plancher de l armoire et vers la bo te de jonction Poussez l appareil compl tement dans l armoire Espace d environ 1 3 8 cm INSTRUCTIONS D INSTALLATION POUR LE MODELE COMBINE FOUR A ENCASTRER FOUR A MICRO ONDES Installez les vis de fixation 7 Installation de

Download Pdf Manuals

image

Related Search

SECURITi securities securities and exchange commission securities act of 1933 securities training corporation securities fraud securities definition securities america securities institute securities industry essentials securities license securities lending securitization definition securities and exchange commission website securities america login securities exchange act of 1934 securitisation securities training corporation login securities act of 1934 securitization theory securities services securities attorney securities act ontario securities attorney near me securities premium securitisation theory