1. M P 26A 0890 M P 26A 0906 Tourner les fermetures rapides 6 et retirer la plaque EPS 7 6 Retirer un peu le bo tier de ventilation 8 desserrer les c bles et retirer compl tement Le bo tier de ventilation 8 7 D visser le cache 9 M P 26A 0905 4 Rabattre le cache 5 vers le haut en position de service M P 26A 0907 AP190 8 Manuel d installation de la batterie de pr chauffage pour Avent P190 P310 P460 M P 26A 0908 AP310 AP460 8 Installer la batterie de pr chauffage 10 et serrer avec des vis 11 M P 26A 0909 AP190 Manuel d installation de la batterie de pr chauffage pour Avent P190 P310 P460 PLUGGIT La ventilation r sidentielle M P 26A 0910 AP310 AP460 9 S curiser les cables 12 l aide d un serre c bles traditionnel 13 10 Installer le bo tier de ventilation 8 dans l ordre inverse dans le systeme de ventilation residentiel E J21 J7 J6 J3 J2 11 3 2 RAR E 5 ae ae O M P 26A 0911 11 Connecter les cables 12 a la platine principale 14 12 Rabattre de nouveau le cache 5 et serrer avec des v
2. PLUGGIT The residential ventilation Electrical preheating APHR Batterie de prechauffage electrique APHR mu pour Pluggit Avent AP1 90 AP31 0 lesch Operating and installation instructions Manuel d utilisation et d installation www pluggit com The technology makes the difference Pluggit s value added innovations for man and the environment The air conduct being installed invisibly in the floor and an ideal 2 Q positioning of the air outlets make for perfectly aligned transverse ventilation Displacement ventilation means that the fresh air Is Supplied to the room almost without causing any draughts and disturbing noise without pressure and preheated during the cold months Plugg Mar Fresh air and heat supply in one quicker more flexible and more energy saving than common heating systems allfloor in ceilings walls above or under concrete and screed allfloo 8 the Pluggit system design offers maximum flexibility with regard to the installation of the ventilation ducts and thus is ideal for the use in new buildings as well as for the refurbishment of existing buildings This innovative technology allows for the supply of exactly the required or desired amount of fresh air thanks to a highly sensitive ServoF low sensor system and control Cost and time saving the unit adapts to the system characteristics at the touch of a button after the installation and automatically calibrat
3. AUS ES LEO ee 22 Unintended USE a a TE A TT EET LS NNT T EE 3 Vu CELL WE Be LT 6 le UR ES LE MEN 5 Decommissioning disposal cccssseeccsssecceseeeceeeeccsseecueeeeeuaeeeeueceeeueeeeeneseeeeessenesseseseesens 5 1 Decommissioning in case of dismantling ENEE 5 2 Packaging cccccececcccceeeeeceeceeeeeeeee se eeeeeeeeeeeeeeeaeeeeeeeeeeeeeeeeaaaeeeeeeeseaeeeeeseeeeeeesseceeeeessaeeeeeeesaneeeeees eo CADRES E A SOMMAIRE 1 Consignes g n rales de s curit csccceeeeceseeeeceseeeeseeeuneeeeneeeusseeeaeeeeseenaneeeeseenensesaeeseaeeens 2 Consignes g n rales ccceccceeeeeeeeeeeeeeeeueeeenseeecuseeeeneeeuseeeesseeeaeeeuaseeuaeeeeeseenegseeeseesaseseseesnens ZV Eet EEN 224 e Ol WOM feet tie E 4 Donn es e EE Mise hors service limination c c cccccsssseecessseeeceseeecenseeeecenseeseauseeeensneeeeeeaseeeoeaseeseesseees 0 Mise hors SET ICO SORTE riiu eei nad inaina an EASi Reik ToD le et OWS E e E E IO preheating register for Avent P190 P310 P460 PLUGGIT The residential ventilation 1 GENERAL SAFETY INFORMATION 3 INSTALLATION A Warning Note The following safety instructions must be observed All following descriptions refer to the B version of the since damage and injury may otherwise result room ventilation unit The A version of the room ventila e Please read these installation instructions care tion unit is to be installed analogously fully before starting to install the prehea
4. The residential ventilation 4 TECHNICAL DATA 5 DECOMMISSIONING DISPOSAL AP 190 700W AP 310 1200W 2x 600W 5 1 DECOMMISSIONING IN CASE OF DISMANTLING AP 460 1600W 2x 800W Decommissioning must only be carried out by qualified per sonnel e Disconnect the unit from power supply e Disconnect all poles of the unit from the power supply system 5 2 PACKAGING The transport and protective packaging are usually manu factured from reusable materials All packaging material must be disposed of according to local laws and regulations 5 3 OLD APPLIANCE The preheating register contains valuable materials and substances which should be kept separate from residual waste The old appliance can be delivered to the local recycling company for recycling IO preheating register for Avent P190 P310 P460 5 ysnbuz PLUGGIT La ventilation r sidentielle SOMMAIRE 1 Consignes g n rales de s curit ccesceeeeceesecneeeeneeeneeceseceneecseneseeuaneeanseoaseseaeeoasenenesnanens 7 2 Consignes Ee UE 7 e APR MS LS E 7 22 AMS SO OO CONTI OPA ane ad a en a ele lil 7 Ee e 7 3 INSULANO EE 7 4 Donn es techniques ccccccseceseescnecccseeneeeeuseeeneeeuseenseeeuseeuceeessenseeeseeuseeeeseuseeneeseuseenaesenes 10 5 Mise hors service limination scccccssccccssecceseeeceeeeececeeeueceeeneceeeeceeeeneaeeeeeeeeeseeeeseeneeseass 10 5 1 Mise hors service lors du d montage 2 10 5 2 Conditionnemen
5. aleur ajout e pour l homme et l environnement 2Q La pose du conduit d air de mani re invisible dans le sol et un positionnement ideal des sorties d air permettent une ventilation transversale parfaitement orient e La ventilation a d placement d air signifie que l air frais est amen dans la piece presque sans courants d air ni bruits parasites sans pression et de facon pr chauff e en hiver Plugg Mar Airfrais et apport de chaleur le tout en un plus rapide plus flexible et plus nerg tique que les syst mes de chauffage traditionnels allfloor dans les plafonds les murs sur ou sous le b ton et la chape le sys allfloo t me con u par Pluggit offre une flexibilit maximale concernant la pose des conduites de ventilation et est ainsi id al pour une utilisation dans les b ti ments neufs comme lors de la r novation de b timents d j construits j Cette technologie innovante permet une alimentation en air frais avec la quan tit exacte n cessaire ou souhait e gr ce des capteurs et une commande ServoFlow hautement sensibles Apr s l installation le syst me est r glable par une simple pression sur la caract ristique de l installation permettant d cono miser du temps et des frais et se recalibre toujours automatiquement des intervalles de temps r guliers lt E E gt conomie d nergie un haut taux de r cup ration de chaleur permet au syst me de ventilation de para tre pe
6. atterie de pr chauffage est concue pour une installa tion dans les syst mes de ventilation r sidentiels Avent P190 P310 P460 2 2 UTILISATION NON CONFORME Toute utilisation de la batterie de pr chauffage autre que celle d crite au point lt lt Utilisation conforme gt gt n est pas autoris e 2 3 GARANTIE Les consignes techniques indiqu es dans le pr sent ma nuel d installation doivent tre respect es afin de faire va loir pleinement Le droit La garantie l gale Manuel d installation de la batterie de pr chauffage pour Avent P190 P310 P460 PLUGGIT La ventilation r sidentielle 3 INSTALLATION Remarque Toutes les informations suivantes sont d crites pour le syst me de ventilation r sidentiel de la variante B Lors de l installation du syst me de ventilation r sidentiel de la variante A il convient de proc der par analogie Consulter le manuel d utilisation et d installation du syst me de ventilation r sidentiel afin d obtenir de plus amples informations Risque de blessures Avant l installation de la batterie de pr chauffage d brancher le syst me de ventilation r sidentiel sur tous les p les dans le cas contraire des bles sures peuvent tre entrain es M P 26A 0925 D crocher le cache design 1 2 Desserrer les vis 2 et retirer le couvercle frontal 3 7 sieduel j PLUGGIT La ventilation r sidentielle
7. emove designer cover 1 2 Unscrew screws 2 and remove front cover 3 2 IO preheating register for Avent P190 P310 P460 DS M P 26A 0890 M P 26A 0905 4 Fold the cover 5 upwards in service position PLUGGIT The residential ventilation M P 26A 0906 Turn quick release fasteners 6 and remove EPS panel 7 6 Slightly pull ventilator box 8 out loosen cable and pull ventilator box 8 out completely 7 Unscrew cover 9 M P 26A 0907 AP190 IO preheating register for Avent P190 P310 P460 3 ysnbuz PLUGGIT e residential ventilation M P 26A 0908 M P 26A 0910 AP310 AP460 AP310 AP460 8 Install preheating register 10 and tighten with 9 Secure cable 12 using customary cable tie 13 screws 11 10 Install ventilator box 8 in reversed order in the room ventilation unit dek dt JO J3 J M P 26A 0909 AP190 M P 26A 0911 11 Connect cable 12 to the main board 14 12 Fold down cover 5 and tighten with screws 4 13 Tighten front cover at the room ventilation unit IO preheating register for Avent P190 P310 P460 PLUGGIT
8. es itself consistently at regular intervals lt E E gt Energy efficiency a high heat supply rate alone makes a ventilation system seem effective and energy efficient only at first glance The decisive factor for an assessment is rather the ratio of the energy spent to the attained heat recovery rate the so called electrical energy efficiency Due to a high tightness a consumption optimised device design and the latest heat exchanger technology our ventilation systems attain excellent ratings in terms of heat recovery and energy efficiency The CleanSafe principle guarantees a very low pollution potential of our distribution system due to smooth surfaces and a trouble free cleaning concept the convincing results of which have been confirmed by an independent testing institute e ww CleanSafe DR AN aa a Appetite for fresh air in your building refresh The unique comfort ventilation system for the energetic refurbishment of existing buildings Appetite for fresh air You can get more information on the company the intelligent technology of Pluggit comfort ventilation systems references and regional contacts at www pluggit com or as an on line dialogue at www lueftungsblog de PLUGGIT The residential ventilation 2 3 Garantie 3 Installation PLUGGIT e residential ventilation TABLE OF CONTENTS 1 General safety information see NEEN KEEN R KENE KENE EE REENEN RENE ENEE EE NEEN R ENKER KEREN Cen E A LR
9. ign pour votre maison PluggLine Flush mount standard covers Caches standard surface plane PluggFlex R Round ventilation pipes for installation in wet concrete Conduits d a ration ronds pour une installation dans du b ton mouill PluggVoxx The most healthy air for your home Lair le plus sain pour votre maison PLUGGIT PLUGGIT PLUGGIT The residential ventilation MM Wm The residential ventilation PluggLine pesigner covers Plugg Line standard covers Plugg Flex R round ventilation pipes i Piese The breakthrough in round ventilation pipes Fresh air with style ravishingly beautiful LA The flush mount designer floor air outlet for all floors Winner of thi award 2013 For all floor installation heights ranging from 130 mm up to 190 mm Premium quality stainless steel design www pluggit com PLUGGIT GmbH Valentin Linhof StraBe 2 81829 Munich Telephone 49 89 411125 0 Fax 49 89 411125 100 PLUGGIT GmbH Valentin Linhof StraBe 2 81829 Munich T l phone 49 89 411125 0 Fax 49 89 411125 100 LUGGIT The residential ventilation PLUGGIT sar rain www pluggit com DH 39M BIA VH 190 460 E F
10. is 4 13 Fixer le couvercle frontal au syst me de ventilation r si dentiel 9 sieduelj PLUGGIT La ventilation r sidentielle 4 DONN ES TECHNIQUES 5 MISE HORS SERVICE LIMINATION AP 190 700W AP 310 1200W 2x 600W 5 1 MISE HORS SERVICE LORS DU DEMONTAGE AP 460 1600W 2x 800W La mise hors service doit tre effectu e uniquement par du personnel sp cialis et qualifi e Mettre l installation hors tension e De brancher l installation complete sur tous les p les 5 2 CONDITIONNEMENT L emballage de transport et de protection est fabriqu lar gement a base de mati res recyclables Tous les mat riaux d emballage doivent tre limin s con form ment aux dispositions locales 5 3 APPAREIL USAG La batterie de pr chauffage contient des mati res et des substances pr cieuses qui ne doivent pas tre jet es avec les d chets non recyclables L appareil usag peut tre remis une soci t de r cup ra tion locale pour tre recycl 1 0 Manuel d installation de la batterie de pr chauffage pour Avent P190 P310 P460 PLUGGIT La ventilation r sidentielle Manuel d installation de la batterie de pr chauffage pour Avent P190 P310 P460 1 1 L4 sieJuel d PLUGGIT La ventilation r sidentielle 1 2 Manuel d installation de la batterie de pr chauffage pour Avent P190 P310 P460 La technologie fait la difference Les innovations de Pluggit repr sentent une v
11. rformant et nerg tique uniquement de mani re superficielle Le rapport entre l nergie consomm e et le taux de r cup ration de chaleur ce que l on appelle l efficacit nerg tique lec trique est beaucoup plus d terminant pour une appr ciation Avec une haute tanch it un design optimis en mati re de consommation et la derni re technologie d changeur thermique nos syst mes de ventilation obtiennent d excellentes valeurs en ce qui concerne la r cup ration de chaleur et l effi cacit nerg tique Le principe de CleanSafe garantit un potentiel de pollution pratiquement C lean Safe impossible de notre syst me de distribution gr ce aux surfaces lisses ainsi qu un concept de nettoyage sans difficult s dont les r sultats convaincants d un organisme de contr le ind pendant sont confirm s az Vous avez envie d air frais dans un b timent d j construit refresh Le syst me de ventilation de confort unique pour la r novation nerg tique de b timents deja existants Vous avez envie d air frais Vous trouverez de plus amples informations concernant l entreprise la technique intelligente des syst mes de ventilation de confort des r f rences et les partenaires r gionaux sur www pluggit com ou sous forme de dialogue sur www lueftungsblog de PLUGGIT La ventilation r sidentielle Further good ideas of D autres bonnes id es de LP PluggLine Designer covers for your home Caches des
12. t cecccecccececseeceeececececeeeeeeeeeeaneeaeeeseeeneeeteeeteeeeaeeeaneeaeeseeesesteeteetseeeaneetees 10 D E E 10 6 Manuel d installation de la batterie de pr chauffage pour Avent P190 P310 P460 1 CONSIGNES GENERALES DE SECURITE A Avertissement Les consignes de s curit suivantes doivent tre respect es dans le cas contraire des blessures ou des dommages peuvent tre entra n s e Avant de commencer utiliser la batterie de pre chauffage lire attentivement Le pr sent manuel d utilisation e L installation et tous les travaux lectriques doi vent tre r alis s uniquement par du personnel sp cialis et qualifi e S assurer que l ensemble des directives l gales et nationales r glements de protection contre les accidents et r glements reconnus de la tech nique soit respect lors de l installation et de la mise en service de la batterie de pr chauffage e Toute responsabilit est d clin e en cas de dom mages r sultant d un stockage non conforme au produit et d une installation incorrecte ou d une utilisation non conforme aux dispositions e Sous r serve de modifications techniques 2 CONSIGNES G N RALES 2 1 UTILISATION La batterie de pr chauffage assure un fonctionnement constant de la ventilation r sidentielle en cas de temp ra tures ext rieures froides L air ext rieur amen est r chauff avant l entr e dans le syst me de ventilation r si dentiel La b
13. ting For further information please refer to the operating register and installation instructions of the room ventilation unit e The installation and all electrical work must only be carried out by qualified expert personnel aE ATE AA Ri injury e When installing and commissioning the pre Jr heating register observe allnecessary legal and Before installing the preheating register discon national requirements accident prevention reg nect all poles of the room ventilation unit from the ulations and generally accepted codes of prac power supply system since injury may otherwise tice and comply with them result e Damages resulting from inappropriate storage of the product improper installation or unin tended use are excluded from any Liability e Technical changes reserved 2 GENERAL NOTES 2 1 INTENDED USE The preheating register ensures continuous operation of the room ventilation unit at cold outside temperatures The inflowing outside air is heated before entering the room ventilation unit The preheating register is intended to be installed in the room ventilation units Avent P190 P310 P460 2 2 UNINTENDED USE Any use of the preheating register other than that described In Intended use shall not be permissible 2 3 WARRANTY In order to preserve your full statutory warranty claim the HE technical guidelines in these installation instructions must be observed 1 R

Download Pdf Manuals

image

Related Search

Related Contents

FDT-6604 Series User Manual  MT Task Creation User Manual  P5SJ-A Mainboard User`s Manual  Aerador Submerso Inject-air FI}NAL 18042012  Arquivo do Manual Ummi.  SYSTRAN 7 Premium Translator  HP EliteDesk 800 G1  MODELO SW470 - Chamberlain  Le risposte “ufficiali” \(da 1 a 10\)ai numerosi quesiti sull    