        Reflotron Hemoglobin
         Contents
1.   Labor und Diagnose  7th ed  TH Books Verlagsgesellschaft mbH   Frankfurt Main  2007     Symbols   Symbole   Symboles   Simboli    Roche Diagnostics uses the following symbols and signs in addition to those listed in the  ISO 15223 1 standard    In Erweiterung zur ISO 15223 1 werden von Roche Diagnostics  folgende Symbole und Zeichen verwendet    Roche Diagnostics utilise les signes et les  symboles suivants en plus de ceux de la norme ISO 15223 1    Oltre a quelli indicati nello  standard ISO 15223 1  Roche Diagnostics impiega i seguenti simboli     Analyzers Instruments on which reagents can be used    Ger  te  auf denen die Reagenzien verwendet werden  k  nnen   Analyseurs appareils compatibles avec les  r  actifs   Analizzatori strumenti su cui i reagenti possono  essere usati     SYSTEM         PRECINORM and REFLOTRON are trademarks of Roche   All other product names and trademarks are the property of their respective owners        2013  Roche Diagnostics    CE    ul Roche Diagnostics GmbH  Sandhofer Strasse 116  D 68305 Mannheim  www roche com    05903777001  2014 11 V2 1    
2.  Auftragezone applizieren  ohne diese mit der  Pipettenspitze zu ber  hren  Luftblasen vermeiden     Klappe bzw  Schieber   ffnen  Reagenztr  ger innerhalb von 15 Sekunden nach dem   Auftragen der Probe in die F  hrungsschiene stecken und waagrecht bis zum sp  rbaren   Einrasten einschieben  Schieber bzw  Klappe schlie  en      Im Display erscheint die Abk  rzung des Testparameters  wenn der Teststreifen korrekt  eingelegt und der Magnetcode eingelesen wurde  Das Ergebnis wird je nach Einstellung  des Ger  tes angezeigt    Kalibration    Die Festlegung der Funktionskurve von Reflotron Hemoglobin zur Umrechnung von  Reflexionswerten in Konzentrationen erfolgt chargenspezifisch unter Verwendung der  Sysmex SLS H  moglobin Methode     Die Daten werden   ber das Magnetband automatisch an das Ger  t   bermittelt     Qualit  tskontrolle  Zur Qualit  tskontrolle Precinorm HB verwenden     Die Kontrollintervalle und Kontrollgrenzen sind den individuellen Anforderungen jedes  Labors anzupassen  Die Ergebnisse m  ssen innerhalb der definierten Bereiche liegen   Jedes Labor sollte Korrekturma  nahmen f  r den Fall festlegen  dass Werte au  erhalb der  festgelegten Grenzen liegen     Bei der Qualit  tskontrolle die entsprechenden Gesetzesvorgaben und Richtlinien beachten     Berechnung   Die gemessene H  moglobinkonzentration wird mit Hilfe einer Funktion und  Umrechnungsfaktoren  die dem Ger  t durch das Magnetband auf der  Reagenztr  gerunterseite   bermittelt werden  ausgewertet und a
3.  data   The data for the Reflotron Hemoglobin assay were determined in evaluation studies  The  majority of the test results were within the given ranges    Precision   Repeatability  within run precision     CV  coefficient of variation  in the normal and in the pathological range  3 98    sample  material  EDTA or heparinized blood    Intermediate precision  between day precision     CV in the normal and in the pathological range  3 64    sample material  control materials     Method comparison   A comparison of the Reflotron Hemoglobin assay  y  with the Sysmex SLS hemoglobin  method  x  using EDTA  heparinized blood gave the following correlations  n   75     EDTA venous blood  y   1 043x   0 87  r   0 86   Heparinized blood  y   1 163x   1 79  r   0 83   For further information  please refer to the appropriate operators manual for the analyzer  concerned  and the Method Sheets of all necessary components    A point  period stop  is always used in this Method Sheet as the decimal separator to mark    the border between the integral and the fractional parts of a decimal numeral  Separators for  thousands are not used     Significant additions or changes are indicated by a change bar in the margin     Deutsch  Anwendungszweck  Test zur quantitativen Bestimmung von H  moglobin im Blut mit Reflotron Systemen     Zusammenfassung    Die Bestimmung des Gesamth  moglobins im Blut erlaubt in Verbindung mit weiteren  Parametern wie H  matokrit Wert und Erythrozytenzahl wertvolle Au
4.  es aux exigences  du laboratoire  Les r  sultats doivent se situer dans les limites de confiance d  finies  Chaque  laboratoire devra   tablir la proc  dure    suivre si les r  sultats se situent en dehors des limites  d  finies    Se conformer    la r  glementation gouvernementale et aux directives locales en vigueur  relatives au contr  le de qualit      Calcul des r  sultats    La concentration en h  moglobine est calcul  e automatiquement    partir du r  sultat de la  mesure ainsi que des facteurs de fonction et de conversion lus par la bande magn  tique  situ  e au dos de chaque bandelette  La concentration en h  moglobine est exprim  e en  g dL  en g L ou en mmol L selon que l appareil a   t   r  gl   pour afficher les r  sultats en  unit  s conventionnelles ou en unit  s SI     Facteurs de conversion  g dL x 0 621   mmol L  g dL x 10   g L    Limites d utilisation   interf  rences   Un remplissage incomplet de la microcuvette  du    une quantit   d   chantillon insuffisante   conduit    des r  sultats erron  s  Dans ce cas  le test doit   tre r  p  t       ce jour  aucune  influence de substances endog  nes ou exog  nes sur le r  sultat du test n a   t   observ  e   L h  matocrite jusqu    55   n a pas d influence sur le r  sultat du test  3   Le sang capillaire ne peut pas   tre utiliser comme mat  riel d   chantillon pour le test  Reflotron Hemoglobin  Utiliser uniquement du sang veineux    Pour le diagnostic  les r  sultats doivent toujours   tre confront  s aux do
5.  in analisi di valutazione  La  maggioranza dei valori misurati    risultata all interno degli intervalli specificati    Precisione   Ripetibilit    precisione nella serie      CV  coefficiente di variazione  nell intervallo normale e nell intervallo patologico  3 98     campioni  sangue eparinato o con EDTA     Precisione intermedia  precisione intergiornaliera      CV nell intervallo normale e nell intervallo patologico  3 64    campioni  materiali di controllo     Confronto tra metodi    Il confronto del test Reflotron Hemoglobin  y  con la determinazione dell emoglobina con  metodo SLS di Sysmex  x   impiegando sangue con EDTA eparinato  ha prodotto le  seguenti correlazioni  n   75      sangue venoso con EDTA  y   1 043x   0 87  r   0 86  sangue eparinato  y   1 163x   1 79  r   0 83    Per ulteriori informazioni  consultare il manuale d uso appropriato per il relativo analizzatore  e le metodiche di tutti i componenti necessari     In questa metodica  per separare la parte intera da quella frazionaria in un numero decimale  si usa sempre il punto  Il separatore delle migliaia non    utilizzato     Le aggiunte o modifiche significative sono indicate mediante una linea verticale posizionata  al margine     References   Literatur   R  f  rences bibliographiques   Letteratura   1 Van Assendelft OW  Spectrophotometry of Hemoglobin Derivatives  Royal van Gorem  Ltd  The Netherlands  1970    2 Koller PU  et al  Lab med 1989    3  Weisshaar D  et al  Lab med 1988     4 Thomas L
6. 10   g L       Limiti del metodo   interferenze    Se la microcuvetta non viene riempita completamente a causa di un imperfetto dosaggio  si  possono ottenere risultati errati  In tal caso    necessario ripetere il test  Finora non sono  state osservate interferenze sui risultati del test da parte di sostanze endogene o esogene   Valori di ematocrito fino al 55   non influiscono sui risultati del test 23    Non  amp  possibile impiegare il sangue capillare come campione con il test  Reflotron Hemoglobin  L unico campione adeguato    il sangue venoso     Ai fini diagnostici  i risultati devono sempre essere valutati congiuntamente con la storia  clinica del paziente  con gli esami clinici e con altre evidenze cliniche    Intervallo di misura   5 0 20 0 g dL  3 10 12 4 mmol L oppure 50 200 g L    Nel caso in cui il valore di emoglobina misurato risulti al di sopra dell intervallo di misura  specifico del test Reflotron Hemoglobin  il campione pu   essere diluito 1   1 con soluzione  salina fisiologica  Moltiplicare il risultato per il fattore 2    Valori di riferimento   Uomini   14 17 5 g dL  8 7 10 9 mmol L oppure 140 175 g L    Donne   12 3 15 3 g dL  7 6 9 5 mmol L oppure 123 153 g L    Ogni laboratorio deve controllare l applicabilit   dei valori di riferimento alla propria  popolazione di pazienti e  se necessario  determinare intervalli di riferimento propri    Dati specifici sulla performance del test   I dati relativi al test Reflotron Hemoglobin sono stati determinati
7. Probe  nicht ber  hren     Reagenz Handhabung  Die Teststreifen sind gebrauchsfertig     Lagerung und Haltbarkeit  Bei 2 30   C aufbewahren   Teststreifen nicht   ber das angegebene Verfallsdatum hinaus verwenden     Probenentnahme und Vorbereitung    Zur Probenentnahme und  vorbereitung nur geeignete R  hrchen oder Sammelgef    e  verwenden     Frisches Venenblut sofort nach der Entnahme einsetzen     In geschlossenen Gef    en aufbewahrtes EDTA  oder Heparinblut innerhalb von 24 Stunden  verwenden  Probe vor Durchf  hrung der Messung gut aufsch  tteln  um die homogene  Verteilung der zellul  ren Bestandteile zu gew  hrleisten    Fluorid darf als Antikoagulanz nicht verwendet werden     Probenvolumen  30 uL    Gelieferte Materialien  1 R  hre mit 30 Teststreifen    Zus  tzlich ben  tigte Materialien    Reflotron Ger  t  Reflotron Pipette  Reflotron Pipettenspitzen      Reflotron Precinorm HB       0 9  NaCl  Allgemein   bliche Laborausr  stung    Testdurchf  hrung  Um eine einwandfreie Funktion des Tests sicherzustellen  sind die Anweisungen in diesem  Dokument zu befolgen  Ger  tespezifische Testanweisungen sind im entsprechenden  Bedienungshandbuch zu finden   Einen Teststreifen aus der R  hre entnehmen  R  hre nach Entnahme eines Teststreifens  sofort wieder fest verschlie  en       Bei allen Reflotron Tests ist ein Probenvolumen von 30 uL erforderlich        Ben  tigtes Probenvolumen mit einer Pipette  z B  Reflotron Pipette  aufnehmen und  zentral auf den roten Teil der
8. antillons de plasma h  parin   ou recueillis sur EDTA  a  donn   les corr  lations suivantes  n   75     sang veineux recueilli sur EDTA  y   1 043x   0 87  r   0 86   sang h  parin    y   1 043x   1 79  r   0 83   Pour de plus amples informations  se r  f  rer au manuel d utilisation de l analyseur concern    et aux fiches techniques de tous les r  actifs n  cessaires    Dans cette fiche technique  le s  parateur d  cimal pour partager la partie d  cimale de la  partie enti  re d un nombre d  cimal est un point  Aucun s  parateur de milliers n est utilis       Les modifications importantes par rapport    la version pr  c  dente sont signal  es par une  barre verticale dans la marge     Italiano   Finalit   d   uso   Test per la determinazione quantitativa dell emoglobina in campioni di sangue  impiegando  sistemi Reflotron    Sommario    La determinazione dell emoglobina totale nel sangue  insieme ad altri parametri quali il  valore di ematocrito ed il numero degli eritrociti  fornisce preziose informazioni sulle funzioni  del sistema circolatorio estremamente importanti per l organismo  il trasporto di ossigeno   quello di biossido di carbonio e la regolazione dell equilibrio acido base     La determinazione dell emoglobina    perci   fondamentale per ogni diagnosi di chimica  clinica  Anche la determinazione isolata dell emoglobina pu   indicare la presenza di anemie   il cui tipo  contenuto ridotto di emoglobina o numeri ridotti di eritrociti     da accertarsi in  diagnos
9. ctors read from the magnetic strip on the lower face of  each test strip  The concentration is displayed in g dL  g L or mmol L depending on whether  the instrument has been set to show conventional or SI units     Conversion factors  g dL x 0 621   mmol L  g dL x 10   g L    Limitations   interference    Incomplete filling of the microcuvette due to improper dosing can lead to incorrect values   The test must be repeated  No influence of endogenous or exogenous substances on the  result of the test has been found to date  Haematocrit values up to 55   have no influence  on the result of the test 23    Capillary blood samples cannot be used as sample material with the Reflotron Hemoglobin  test  Only venous blood is a suited sample material    For diagnostic purposes  the results should always be assessed in conjunction with the  patients medical history  clinical examination and other findings    Measuring range   5 0 20 0 g dL  3 10 12 4 mmol L  or 50 200 g L    If the measured hemoglobin value is above the measuring range of the   Reflotron Hemoglobin assay  the sample may be diluted 1   1 with physiological saline  solution  Multiply the result by a factor of 2    Expected values   Men   14 17 5 g dL  8 7 10 9 mmol L or 140 175 g L    Women   12 3 15 3 g dL  7 6 9 5 mmol L or 123 153 g L    Each laboratory should investigate the transferability of the expected values to its own  patient population and if necessary determine its own reference ranges    Specific performance
10. en association avec d autres  param  tres comme le taux d   h  matocrite et la num  ration   rythrocytaire  d obtenir de  pr  cieuses informations sur des fonctions extr  mement importantes du syst  me circulatoire   transport de l oxyg  ne  transport du dioxyde de carbone et r  gulation de l   quilibre  acido basique     Le dosage de l h  moglobine est donc un des   l  ments fondamentaux de toute   valuation en  chimie clinique  Le dosage de l h  moglobine est    lui seul d un indicateur de la pr  sence  d une an  mie dont les causes  faible taux d h  moglobine ou faible nombre d   rythrocytes   devront ensuite   tre recherch  es    l aide d analyses compl  mentaires     Principe   Le principe du Reflotron Hemoglobin repose sur l oxydation de l h  moglobine en  m  th  moglobine par le ferricyanure de potassium  Fe      Fe      Pour acc  l  rer la r  action   les   rythrocytes sont lys  s par la saponine      h  moglobine   K   Fe  CN e     La concentration en h  moglobine  proportionnelle    l intensit   de la coloration form  e  est  mesur  e    37   C    une longueur d onde de 567 nm  Le r  sultat est affich   en g dL  en g L  ou en mmol L apr  s environ 120 secondes            gt  m  th  moglobine    R  actifs   Composants par test    KafFe  CN s   324 ug  saponine  324 ug  tampon  Precautions d   emploi et mises en garde    Pour diagnostic in vitro    Observer les precautions habituelles de manipulation en laboratoire    L   elimination de tous les d  chets doit   tre ef
11. ermitteln     Spezifische Leistungsdaten des Tests    Die Daten f  r den Reflotron Hemoglobin Test wurden in Erprobungsuntersuchungen  ermittelt  Die Mehrheit der Testergebnisse lag innerhalb der angegebenen Bereiche     Pr  zision   Wiederholpr  zision  Pr  zision in der Serie     VK  Variationskoeffizient  im Normalbereich und im pathologischen Bereich  3 98     Probenmaterial  EDTA  oder Heparinblut   Zwischenpr  zision  Tag Tag Pr  zision     VK im Normalbereich und im pathologischen Bereich  3 64    Probenmaterial   Kontrollmaterialien    Methodenvergleich   Ein Vergleich des Reflotron Hemoglobin Tests  y  mit der Sysmex SLS H  moglobin  Methode  x  in EDTA  oder Heparinblut ergab folgende Korrelationen  n   75    EDTA Venenblut  y   1 043x   0 87  r   0 86   Heparinblut  y   1 163x   1 79  r   0 83    Weitergehende Informationen siehe Bedienungshandbuch des jeweiligen Ger  tes sowie die  Methodenbl  tter aller erforderlichen Komponenten     Um die Grenze zwischen dem ganzzahligen Teil und dem gebrochenen Teil einer Zahl  anzugeben  wird in diesem Methodenblatt immer ein Punkt als Dezimaltrennzeichen  verwendet  Tausendertrennzeichen werden nicht verwendet     Signifikante Erg  nzungen oder   nderungen sind durch eine Markierung am Rand  gekennzeichnet     Frangais   Domaine d utilisation   Test pour la d  termination quantitative de l h  moglobine dans le sang sur les analyseurs  Reflotron     Caract  ristiques   Le dosage de I   hemoglobine totale dans le sang permet  
12. f 30 uL      Apply the required volume of sample onto the centre of the red application zone using a  pipette  e g   Reflotron pipette    being careful not to touch the application zone  Avoid  air bubbles       Open the flap or sliding cover  Within 15 seconds of applying the sample  place the test  strip onto the guide  and slide it forward horizontally until it locks into place  Close the  sliding cover or flap      The test parameter abbreviation is shown on the display  if the test strip has been  correctly inserted and the magnetic code has been read  The result is displayed  depending on the setting of the instrument     Calibration   The function curve for the Reflotron Hemoglobin assay for converting reflectance values into  concentrations is defined for each lot using the Sysmex SLS hemoglobin method    The parameters of the curve are automatically transferred to the instrument via the magnetic  strip during testing    Quality control   For quality control  use Precinorm HB    The control intervals and limits should be adapted to each laboratory   s individual    requirements  Values obtained should fall within the defined limits  Each laboratory should  establish corrective measures to be taken if values fall outside the defined limits     Follow the applicable government regulations and local guidelines for quality control     Calculation    The hemoglobin concentration is calculated automatically from the measurements taken  as  well as function and conversion fa
13. fectu  e conform  ment aux dispositions l  gales   Fiche de donn  es de s  curit   disponible sur demande pour les professionnels       viter tout contact avec la zone de d  p  t de la bandelette test  par ex  lors du pipetage de  l   chantillon     Pr  paration des r  actifs   Les bandelettes tests sont pr  tes    l emploi    Conservation et stabilit     Conservation entre 2 et 30   C    Ne pas utiliser la bandelette test apr  s la date de p  remption     05903777001  2014 11 V2 1    Prelevement et preparation des Echantillons   Pour le pr  l  vement et la pr  paration des   chantillons  utiliser uniquement des tubes ou  r  cipients de recueil appropri  s    Utiliser du sang veineux frais et effectuer l analyse imm  diatement apr  s le pr  l  vement   Le sang recueilli sur h  parine ou EDTA doit   tre conserv   dans des r  cipients bouch  s et  utilis   dans un d  lai de 24 heures  Bien m  langer l   chantillon avant de proc  der    la  mesure afin d assurer une r  partition homog  ne des   l  ments figur  s    Ne pas utiliser le fluorure comme anticoagulant    Volume de l   chantillon  30 uL    Materiel fourni  1 tube de 30 bandelettes tests    Materiel auxiliaire necessaire    Reflotron instrument  Reflotron pipette  Reflotron pipette tips      Reflotron Precinorm HB      Solution de NaCl    0 9    Equipement habituel de laboratoire    Realisation du test   Pour obtenir les performances analytiques optimales  suivre attentivement les instructions   donn  es dans le pr  sen
14. i     Reflotron Hemoglobin       E  Y    Evsen   10744964  30   Reflotron    English  Intended use  Test for the quantitative determination of hemoglobin in blood with Reflotron systems     Summary   Determination of the total hemoglobin in the blood  in combination with other parameters like  the haematocrit and the red cell count  provides valuable information about functions of the  circulatory system which are extremely important for the organism  oxygen transport  carbon  dioxide transport and regulation of the acid base balance     Determination of hemoglobin is thus one of the fundamental components of any clinical   chemical evaluation  Determination of hemoglobin alone can already indicate the presence  of anaemia  the type of which  reduced hemoglobin content or reduced numbers of  erythrocytes  must then be established in further tests     Test principle  The Reflotron Hemoglobin test is based on the oxidation of hemoglobin to methemoglobin by    potassium hexacyanoferrate  IIl   Fe2      Fe      In order to speed up the reaction  the  erythrocytes are lysed by saponin      hemoglobin   Kz Fe  CN s     The hemoglobin concentration  proportional to the color intensity  is measured at a  wavelength of 567 nm and 37   C  and is displayed after about 120 seconds in g dL  g L or  mmol L         methemoglobin    Reagents  Components per test   KatFe  CN e   324 ug  saponin  324 ug  buffer     Precautions and warnings    For in vitro diagnostic use    Exercise the normal 
15. i successive    Principio del test   Il test Reflotron Hemoglobin si basa sull ossidazione dell emoglobina in metemoglobina con  l esacianoferrato  III  di potassio  Fe      gt  Fe     Per accelerare il processo di reazione  gli  eritrociti vengono lisati con la saponina      emoglobina   Ks Fe  CN e      metemoglobina    La concentrazione di emoglobina  proporzionale all intensit   del colore  viene misurata ad  una lunghezza d onda di 567 nm e ad una temperatura di 37   C  dopo ca  120 secondi il  display visualizza il risultato in g dL  g L oppure mmol L    Reagenti   Componenti per test    Ks Fe  CN s   324 ug  saponina  324 pg  tampone     Precauzioni e avvertenze    Per uso diagnostico in vitro    Osservare le precauzioni normalmente adottate durante la manipolazione dei reagenti di  laboratorio    Lo smaltimento di tutti i rifiuti deve avvenire secondo le direttive locali    Scheda dati di sicurezza disponibile su richiesta per gli utilizzatori professionali     Evitare sempre il contatto con la zona di reazione della striscia reattiva  ad es  durante il  pipettamento del campione     Utilizzo dei reattivi   Le strisce reattive sono pronte all uso    Conservazione e stabilit     Conservare a 2 30   C    Non usare la striscia reattiva oltre la data di scadenza indicata    Prelievo e preparazione dei campioni    Per il prelievo e la preparazione dei campioni impiegare solo provette o contenitori di  raccolta adatti     Impiegare il sangue venoso fresco immediatamente dop
16. nn  es de l anamn  se  du patient  au tableau clinique et aux r  sultats d   autres examens     Domaine de mesure   5 0 20 0 g dL  3 10 12 4 mmol L ou 50 200 g L    Si la valeur d h  moglobine mesur  e se situe au dessus de la limite sup  rieure de l intervalle  de mesure du test Reflotron Hemoglobin  l   chantillon peut   tre dilu   dans le rapport 1   1  avec une solution physiologique de chlorure de sodium  Multiplier le r  sultat par 2    Valeurs de r  f  rence   Hommes   14 17 5 g dL  8 7 10 9 mmol L ou 140 175 g L    Femmes   12 3 15 3 g dL  7 6 9 5 mmol L ou 123 153 g L     Chaque laboratoire devra v  rifier la validit   de ces valeurs et   tablir au besoin ses propres  domaines de r  f  rence selon la population examin  e     Performances analytiques   Les donn  es ci dessous sont le r  sultat d   tudes d   valuation r  alis  es sur le test   Reflotron Hemoglobin  La majorit   des r  sultats du test se situait dans les intervalles de  valeurs indiqu  s    Pr  cision   R  p  tabilit    pr  cision intra serie     CV  coefficient de variation  dans l intervalle des valeurs normales et pathologiques  3 98     type d   chantillon  sang recueilli sur h  parine ou EDTA   Pr  cision interm  diaire  pr  cision inter jours     CV dans l intervalle des valeurs normales et pathologiques  3 64      chantillon  mat  riaux  de contr  le    Comparaison de m  thodes   Une comparaison du test Reflotron Hemoglobin  y  avec la m  thode Sysmex SLS   hemoglobin  x   effectu  e sur des   ch
17. o della striscia reattiva e l avvenuta lettura del codice magnetico  Il risultato  viene visualizzato a seconda delle impostazioni programmate nello strumento     Calibrazione   La curva di funzione del test Reflotron Hemoglobin per convertire i valori di riflessione in  concentrazioni    definita per ogni lotto utilizzando la determinazione dell emoglobina con  metodo SLS di Sysmex      parametri della curva vengono trasmessi automaticamente allo strumento attraverso la  striscia magnetica durante l esecuzione del test     Controllo di qualit    Per il controllo di qualit    impiegare Precinorm HB   Gli intervalli ed i limiti del controllo dovranno essere conformi alle esigenze individuali di ogni    laboratorio    valori ottenuti devono rientrare nei limiti definiti  Ogni laboratorio deve definire  delle misure correttive da attuare nel caso che alcuni valori siano al di fuori dei limiti definiti     Per il controllo di qualit    attenersi alle normative vigenti e alle linee guida locali     Calcolo  La concentrazione di emoglobina viene calcolata automaticamente in base alle misurazioni  eseguite nonch   alle funzioni e ai fattori di conversione letti nello strumento dalla striscia  magnetica che si trova sulla superficie di contatto di ciascuna striscia reattiva  A seconda  delle impostazioni programmate nello strumento  la concentrazione viene visualizzata in  unit   convenzionali  g dL  g L  o unit   SI  mmol L      Fattori di conversione  g dL x 0 621   mmol L  g dL x 
18. o il prelievo     Il sangue eparinato o con EDTA conservato in recipienti chiusi deve essere utilizzato entro  24 ore  Prima di eseguire il test  agitare bene il campione per assicurare una distribuzione  omogenea dei componenti cellulari    Non usare fluoruro come anticoagulante     Volume del campione  30 uL    Materiali a disposizione  1 contenitore da 30 strisce reattive    Materiali necessari  ma non forniti   Strumento Reflotron   Pipetta Reflotron   Puntali di pipettaggio Reflotron      Reflotron Precinorm HB    NaCl  0 9     Normale attrezzatura da laboratorio    Esecuzione   Per una performance ottimale del test  attenersi alle indicazioni riportate in questo   documento  Per le istruzioni specifiche dello strumento  consultare il manuale d uso   appropriato      Prelevare una striscia reattiva dal contenitore  Richiudere il contenitore ermeticamente  subito dopo aver tolto una striscia reattiva       Volume del campione necessario per tutti i test Reflotron  30 pL       Applicare il volume del campione necessario al centro della zona reattiva rossa con una  pipetta  ad es  pipetta Reflotron   assicurandosi di non toccare tale zona  Evitare la  formazione di bolle d aria       Aprire lo sportello dello strumento  Entro 15 secondi dall   applicazione del campione   inserire la striscia orizzontalmente lungo la guida fino al serraggio completo  Richiudere  lo sportello       Sul display appare l acronimo del parametro test specifico che conferma il corretto  inseriment
19. precautions required for handling all laboratory reagents   Disposal of all waste material should be in accordance with local guidelines   Safety data sheet available for professional user on request     Avoid any contact with the application zone of a test strip  e g   during pipetting of sample    Reagent handling   Test strips are ready for use    Storage and stability   Store at 2 30   C    Do not use the test strip after the specified expiration date    Specimen collection and preparation   For specimen collection and preparation only use suitable tubes or collection containers   Use fresh venous blood immediately after collection     EDTA  or heparinized blood kept in closed containers must be used within 24 hours  Shake  the sample well before performing the test in order to ensure the homogeneous distribution  of the cellular components     Do not use fluoride as an anticoagulant   Sample volume  30 uL    Materials provided  1 container with 30 test strips    Materials required  but not provided     Reflotron instrument  Reflotron pipette  Reflotron pipette tips      Reflotron Precinorm HB      0 9  NaCl  General laboratory equipment    Assay   For optimum performance of the assay follow the directions given in this document  Refer to   the appropriate operators manual for instrument specific instructions      Remove a test strip from the container  Tightly recap the container immediately after  removing a test strip       All Reflotron tests require a sample volume o
20. ssagen   ber die f  r den  Organismus au  erordentlich wichtigen Funktionen des Kreislaufsysstems   Sauerstofftransport  Kohlendioxidtransport und Regulierung des S  ure Basen Haushalts     Die H  moglobinbestimmung geh  rt daher zu den elementaren Ma  nahmen jeder klinisch   chemischen Diagnostik  Bereits die isolierte H  moglobinbestimmung kann Hinweise auf  vorliegende An  mien geben  deren Ursache  verminderter H  moglobingehalt oder  verminderte Erythrozytenzahl im Blut  in der Folgediagnostik abzukl  ren ist     Testprinzip  Der vorliegende Reflotron Hemoglobin Test beruht auf der Oxidation von H  moglobin durch  Kaliumhexacyanoferrat  Ill  zu Meth  moglobin  Fe       Fe      Zur schnelleren  Reaktionsbereitschaft werden die Erythrozyten durch Saponin Iysiert     H  moglobin   K   Fe  CN s          gt  Meth  moglobin    Die H  moglobinkonzentration  proportional zur Farbintensit  t  wird bei einer Wellenl  nge  von 567 nm und 37   C gemessen  Das Ergebnis wird nach ca  120 Sekunden in g dL  g L  oder mmol L angezeigt    Reagenzien   Inhaltsstoffe pro Testfeld    K   Fe  CN s   324 ug  Saponin  324 ug  Puffer    Vorsichtsma  nahmen und Warnhinweise   In vitro Diagnostikum    Die beim Umgang mit Laborreagenzien   blichen Vorsichtsma  nahmen beachten   Die Entsorgung aller Abf  lle ist gem     den lokalen Richtlinien durchzuf  hren   Sicherheitsdatenblatt auf Anfrage f  r berufsm    ige Benutzer erh  ltlich     Auftragezone eines Reagenztr  gers  z B  beim Auftragen einer 
21. t document  Pour les instructions sp  cifiques de l   appareil  se r  f  rer   au manuel d utilisation appropri       Sortir une bandelette test du tube  Toujours bien refermer le tube imm  diatement apr  s  en avoir extrait une bandelette       Le volume d   chantillon pour tous les tests Reflotron est de 30 pL       D  poser le volume d   chantillon requis au centre de la zone rouge de d  p  t    l aide  d une pipette  Reflotron pipette  par ex   en veillant    ne pas toucher la zone de d  p  t   Eviter les bulles d air       Ouvrir le couvercle  Au cours des 15 secondes qui suivent le d  p  t de l   chantillon   introduire la bandelette test horizontalement dans la fente pr  vue    cet effet jusqu au  point de fixation  Refermer le couvercle       L affichage de l abr  viation du param  tre    l   cran confirme que la bandelette a   t    positionn  e correctement et que le code magn  tique a   t   lu  Le type d affichage du  r  sultat d  pend des r  glages de l appareil     Calibration   La courbe de r  f  rence pour le test Reflotron Hemoglobin permet de convertir les valeurs de  r  flectance en concentrations  Elle est d  finie pour chaque lot    l aide de la m  thode  Sysmex SLS hemoglobin    Les param  tres de la courbe sont contenus dans la bande magn  tique de la bandelette et  sont automatiquement transmis    l appareil lors de la mesure     Contr  le de qualit     Utiliser Precinorm HB    La fr  quence des contr  les et les limites de confiance doivent   tre adapt 
22. utomatisch berechnet  Je  nach Einstellung auf konventionelle oder SI Einheiten wird die Konzentration in g dL  g L  oder mmol L angezeigt     Umrechnungsfaktoren  g dL x 0 621   mmol L  g dL x 10   g L    Einschr  nkungen des Verfahrens   Interferenzen   Bei unvollst  ndiger F  llung der Mikrok  vette durch fehlerhafte Dosierung kann es zu  falschen Werten kommen  Der Test ist zu wiederholen  Bisher konnte kein Einfluss durch  endogene oder exogene Substanzen auf das Testergebnis festgestellt werden   H  matokritwerte bis 55   haben keinen Einflu   auf das Testergebnis 2     Kapillarblutproben k  nnen beim Reflotron Hemoglobin Test nicht als Probenmaterial  verwendet werden  Nur ven  ses Blut ist als Probenmaterial geeignet     F  r diagnostische Zwecke sind die Ergebnisse stets im Zusammenhang mit der  Patientenvorgeschichte  der klinischen Untersuchung und anderen  Untersuchungsergebnissen zu werten     Messbereich  5 0 20 0 g dL  3 10 12 4 mmol L bzw  50 200 g L   Liegt der gemessene H  moglobinwert oberhalb des Messbereiches f  r den    Reflotron Hemoglobin Test  so kann die Probe mit physiologischer Kochsalzl  sung im  Verh  ltnis 1   1 verd  nnt werden  Das Ergebnis mit dem Faktor 2 multiplizieren     Referenzwerte  M  nner   14 17 5 g dL  8 7 10 9 mmol L bzw  140 175 g L     Frauen   12 3 15 3 g dL  7 6 9 5 mmol L bzw  123 153 g L     Jedes Labor sollte die   bertragbarkeit der Referenzbereiche f  r die eigenen  Patientengruppen   berpr  fen und gegebenenfalls selbst 
    