Home
        Manuel de cete série
         Contents
1.                                                                                                                                                Part Designation Article code Number Supplier  nr   1 Assembled weighing fork 2    2 Battery pack  assembly without D cellls  BAP IFORK 2 RAVAS  2a with 1 5 V alkaline D cellls  standard  SA BA IFORK ST 2 RAVAS  2b with rechargable 1 2 V D cells  option  SA BA IFORK RC 2 RAVAS  3 Top housing battery pack 2    4 Batteries  D cell        4a   A   regular 1 5 V D cells  standard  BA 1 5 DCELL 8 Buy locally  4b B   rechargeable 1 2 V D cells  option  BA 1 5 DCELL RC 8 Buy locally  5 Bottom housing battery pack 2    6 Philips head screw M3 x 25 12 Buy locally  7 Round head screw M6 x 8 MP SCREW M6 8 LOW STST 6 Buy locally  8 Holder battery pack BAP HOLDER WF 2 RAVAS  9 Weighing fork SA WF 2A 100 45 608  or 2B  2 RAVAS  10 Loadcell LC 2000 4 RAVAS  11 Loadcell fixation ring MP RING LC FIXATION 4 RAVAS  12 Fork shoe FS WF 25 1150 10 15 RAL7021 2 RAVAS  13 Bluetooth transmitterbox  assembly  HO J RWV BLT F1 1 RAVAS  HO J RWV BLT F2 1  13a Labels for Bluetooth transmitterboxes SS LABEL WF SMALL 1 RAVAS   set with nr  1 and 2   14 Coverplate forks  left  MP CP RF LEFT FEM2A  or 2B  1 RAVAS  Coverplate forks  right  MP CP RF RIGHT FEM2A 1  15 Socket head screw M8 x 20 MP BOLT M8 20 CYL 8 Buy locally  16a Mounting bracket indicator MP BRACKET RAM BB 1 RAVAS  16b Indicator mounting support MP SUP RAM CLAMP BASE 1 RAVAS  17 Indicator  assembled  SA 
2.                                                           6 2 Correction de niveau  option     Avant chaque pesage   V  rifier le z  ro      Avant chaque pesage il faut  v  rifier que le syst  me est libre  de charge et n est pas en contact  avec un obstacle     Quand l indicateur ne montre pas  automatiquement le z  ro  il faut  faire une correction manuelle du  z  ro en appuyant bri  vement sur  la touche   gt 0 lt                                                                                                           AE    S 7  Transactions  Commerciales     gt              o o   Y 1      1 eZ      FT F2 1   OK        Se  200               E    NTEP  OK si a       5    3       OIML  OK si a       5         MANUEL D UTILISATION   iForks 15          6 3       Etablir la communication Bluetooth et peser                     A n            F LL i  N                y     Ld    Mettre les iForks en marche    Appuyer sur le bouton bleu sous les deux packs                  2 FT                         D  marrer l   indicateur    Appuyer sur la touche                                                                                                          batteries on off   4          TA COD  NET NET    el e2 e3 F1 F2 1   el e2 e3 F1 F2 1  ID CODE PT TOTAL PCS KGILB S ID CODE PT TOTAL PCS KGLBS  gi j    SN o      o   9            E A  Avant chaque pesage   v  rifier le z  ro    5 Sec   Avant chaque pesage il faut v  rifier que le syst  me  est libre de toute charge   Si l indicateur
3.                       Appuyer sur  ENTER pour  activer la tare          MANUEL D UTILISATION   iForks 24                                  a              NET  lt        1   2      F1 F2 1  ID CODE FT TOTAL Pos           in T   e lem  En       Le cuseur    NET    s allume                               000                                                                                                                                                                                                                      D J   E S  NET  4    el   2      P F2 1  ID CODE PT TOTAL PCS          m  0       Do                    x  Na  1  D                NET    ei 62      P P  1D CODE PT TOTAL PCs von  i 3    l           2 2                  Quand les iforks sont  totalement d  charg  es  la  tare est affich  e en n  gatif                                                         MANUEL D UTILISATION   iForks    25                                        X  gt   gt   gt       YU          gt         Be GEN HE    NET   T 7 el   2      F1 F2    ID CODE PT TOTAL Pos         4 I  0   ei                                                         4  gt    gt  e  NET      el e2 e3 F1 F2 1      T   I             Le poids brut s affiche     nouveau                MANUEL D UTILISATION   iForks    26          6 9 Totalisation et remise    z  ro de la m  moire totalisation                                                               Appuyer sur la touche  hog TOTAL pour ajouter le    poids pes   au total   
4.                 8 S il y a une   SN ee imprimante il y aura   E  esu une impression  Le  AL 222 poids brut  net et la  tare seront imprim  s    NET NET      1 e2  e3 F1 F2    ID CODE PT TOTAL Pcs KOLS                                                                   ID CODE PT TOTAL PCS KOLES    gy T a 7         20 3  D                                    L affichage revient en mode de  pesage automatiquement                EN                                                    Appuyer sur  TOTAL pour      ajouter le poids      a pes   au total                                                                                s S ily a une   O  imprimante il y aura  une impression  Le    A  poids brut  net et la  tare seront imprim  s                   MANUEL D UTILISATION   iForks 27                               i                                                    Le sous total    peut   tre      affich   en m f    appuyant sur la E    touche TOTAL Je   Y I  pendant 3 sec    EN             TOTAL    S    KG LB   x         CLR                                   REMISE A ZERO 8  IMPRESSION        REMISE A ZERO                                           MANUEL D UTILISATION   iForks    28          6 10 Passage KG LB                                                                         RM          Ib  ei  e2      Fi P 1             G TOTAL cs KG es  aH steH      l                  29       MANUEL D UTILISATION   iForks       6 11 Param  tres d utilisation                              
5.           Le menu  utilisateur peut    tre activ   en  appuyant sur  la touche  TOTAL pendant  10 sec                           D          9                    v A             Ces param  tres peuvent   tre modifi  s  si n  cessaire  Voir pages suivantes          gt  QUITTER  amp  SAUVEGARDER                  a gFE   SEE          3 sec          0 r       Retour au  mode pesage            QUITTER SANS SAUVEGARDER                    N             Retour au  CLR  A mode pesage                 MANUEL D UTILISATION   iForks    30             R  gler la coupure automatique de l indicateur  d  lai en minutes                      gt    DO                                 0 min   indicateur toujours allum         R  gler le r  tro   clairage  intensit   en                                                 a Ir         0    pas de r  tro   clairage       31       MANUEL D UTILISATION   iForks        D  s  Activer le port Com 1                                n est pas possible de d  sactiver le Com Port 1           D  s  Activer le port Com 2                                  MANUEL D UTILISATION   iForks 32          DECLARATION DE CONFORMITE    Emis par  RAVAS Europe B V   Toepadweg 7  5301 KA Zaltbommel  Pays Bas    Conform  ment aux exigences des directives suivantes      Directive Basse Tension 2006 95 EC   Directive EMC 2004 108 EC   Codification de la Directive 2006 42 EC   Directive du Conseil 90 384 EEC   Les fourches sont produites selon les standards internationaux suivants    ISO 
6.         les packs batteries rechargeables  option     Le syst  me peut   tre   quip   en option de packs batteries rechargeables et d un chargeur  Chargez la  batterie pendant au moins 8 heures  Ceci emp  chera la perte de capacit   de batterie  V  rifier sur  l   tiquette que le pack batterie est   quip   d une batterie rechargeable  Seuls les packs batteries pourvus    d un accumulateur peuvent   tre recharg  es                                                                                                                                                  An      E    I   Placez d abord le pack batterie    l int  rieur du module de chargeur  puis branchez les adaptateurs sur le  secteur  Quand la batterie est charg  e  la LED rouge du chargeur est allum  e  Apr  s au moins 8 heures  de charge  les packs batteries sont    nouveau charg  s  La LED rouge reste allum  e  m  me lorsque les  packs batteries sont enti  rement charg  s        MANUEL D UTILISATION   iForks 12          5 3 Remplacer les batteries de l indicateur    En standard  l indicateur est   quip   de 4 piles AA   En option l alimentation de l indicateur peut   tre  connect  e sur la batterie du chariot  Cette option doit   tre command  e s  par  ment car l indicateur doit    tre livr   avec le convertisseur appropri   et la carte de stabilisation                    D  NET         ei   2 e FI F2 12    ID CODE PT TOTAL PCS KG LB ta    sese                          Remplacer les piles d  s que le signal  low bat co
7.    MANUEL D UTILISATION DES       MANUEL D UTILISATION   iForks          VEUILLEZ CONSERVER CES INSTRUCTIONS POUR REFERENCES   Pour toute question concernant la dur  e et les termes de la garantie  veuillez contacter votre fournisseur   Vous pouvez   galement vous r  f  rer    nos conditions g  n  rales de vente et de livraison disponibles sur  demande     Le fabriquant refuse toute responsabilit   pour un dommage ou une blessure qui r  sulte du non respect  de ces instructions  ou suite    une op  ration ou un assemblage n  gligent  m  me si ce n est pas  express  ment   tabli dans ce manuel    Dans le cadre de notre politique d am  lioration constante  il est possible que les d  tails du produit  puissent diff  rer de ceux qui sont d  crits dans ce manuel  De ce fait  ces instructions devraient seulement    tre consid  r  es comme des directives pour l installation du produit concern    Ce manuel a   t     tabli  avec tout le soin d    mais le fabricant ne peut pas   tre jug   responsable d une erreur ou des  cons  quences de celles ci  Tous les droits sont r  serv  s et aucune partie de ce manuel ne peut   tre  reproduite de quelque facon        MANUEL D UTILISATION   iForks 2       Table des mati  res    page  1  Introduction 4  2  Avertissements et mesures de pr  caution 4  3  Vue   clat  e  amp  liste de pi  ces 5  4  Installation du syst  me 6  4 1 Montage des   Forks 6  4 2 V  rouillage des iForks 6  4 3 Installation de l indicateur 7  4 4 Mettre en place les modules 
8.   rification du sous total et   Ajout au total impression du total  Incr  menter la valeur  du digit clignotant   Echantillonner un poids PCS Entrer un poids de pi  ce   De pi  ce  Aller au digit gauche  suivant         Mise en marche eee Extinction  Passage des Ib aux kg  CLR Correction    Important    ll est impossible d utiliser une touche tant que le syst  me n est pas stable  et tant que le curseur    load  stable  ne s allume pas   Cela signifie que l indicateur ne fonctionne qu avec une charge stable              MANUEL D UTILISATION     Forks 20       6 7 Messages d erreur    MESSAGES D ERREURS    Affichage    Signification   Signal capteur instable   Syst  me en surcharge   Brut n  gatif  Action non autoris  e   Hors de la plage du z  ro   Pr  cision d   chantillonnage trop faible    Signal d entr  e trop haut   Etalonnage hors plage  n  gatif     Etalonnage hors plage  signal trop faible    2    point  3e  d   talonnage inf  rieur au 1er 2e     Point de consigne 2    point de consigne 1  Non autoris      Homologu   pour transactions commerciales  Pas  d action autoris  e    Le point d   talonnage doit   tre plus   lev   que le  pr  c  dent    Action uniquement autoris  e au d  marrage du syst  me    Probl  me avec fourche 1  pas de communication   Probl  me avec fourche 2  pas de communication     Signal capteur n  gatif   Fourche hors niveau  uniquement pour version  homologu  e transactions commerciales   Probl  me avec la correction de niveau    La batterie de l 
9.  ne d  termine pas le z  ro  automatiquement  il faut le faire manuellement avec  la touche  gt 0 lt    1  4  amp                  NET mes     C3  l el e2 e3 F1 F2 1  1000 j   ge         D 0                                                                                   Le syst  me est pr  t     peser              V  rifier    nouveau le z  ro  avant le pesage suivant           MANUEL D UTILISATION   iForks 16          6 4    Coupure automatique de l indicateur                                                                                                                                        FIN 20 sec   NET    el e2 e3 F1 F2  FN FN FAS              PV E    i 2                      A  2 min  Pas d action   D  marrage du d  compte  Appuyer sur n importe           quelle touche pour     S  annuler la coupure  automatique et retourner  en mode pesage      NET NET      1   2 e3 F1 F2 1   el   2 e F1 F2 1   NAE              re UP  NET       1   2      F1 F2 1                   Indicateur   teint             MANUEL D UTILISATION   iForks    17          6 5 Coupure automatique des   Forks                                                                       iForks   teintes                                                 2 hour Pas de pesage            ine      LI  ri  LY   H    f EN       di A  ER d    LLE  Mettre les   Forks en marche Remettre l indicateur en marche      Appuyer sur le bouton bleu sous les deux appuyer sur la touche on off  d    packs batteries              MA
10. 2328   ISO 2330    EN 1726 1  paragraphe 5 6 5    Concernant  un instrument de pesage non automatique  Fabricant RAVAS Europe B V    Mod  le iForks   Description fourches peseuses    Cette d  claration de conformit   est valable si l instrument mentionn   ci dessus porte la marque    CE  L instrument est v  rifi   en usine et peut   tre utilis   imm  diatement     Nous  RAVAS Europe B V   d  clarons sous notre seule responsabilit   que ce syst  me de    pesage est conforme aux directives et standards mentionn  s        H P M  van Seumeren  Directeur Technique    MANUEL D UTILISATION   iForks 33    
11. 722                                                                               el e2 e3 F1 F2 1  ID CODE PT TOTAL PCS              T                4            4    1   2 e3 F1 F2  ID CODE PT TOTAL PCS DS   iin T                      L indicateur est mis    z  ro  Le  curseur    NET    montre que la  tare est activ  e          MANUEL D UTILISATION   iForks    22                                                                                                                                                                             lt        gt              LU UL  NET  4    ei ei           F2  ID CODE PT TOTAL PCS KBG  F4 IN  ZI            4               L affichage montre la valeur  nette de la charge                                  Le poids brut est maintenant  affich      4      lt       NET  el e2 e3 F1 F2  A                  me 5  E        S NXN 2    S XA  z T                                                                                  23       MANUEL D UTILISATION   iForks       6 8 2  Pesage net   tare manuelle  PT                                                              25                                       va                                                     sur la  touche PT pendant  3 secondes                                              Appuyer sur     la touche     jusqu      la   valeur d  sir  e                                                                                       surla  touche  jusqu      la      valeur  d  sir  e             
12. IN 31 IFORK 1 RAVAS  18 Charger  option  SA CH WF DUAL 1 RAVAS  19 Level correction sensor  option  EP LEVELSENSOR 1 RAVAS  20 Touch panel FR 31N RAV HO 1 RAVAS  21 Socket head screw M6x40 MP BOLT M6 40 CYL 2 RAVAS  22 Top housing indicator  red  HOP RAV RAL3000 UPPER 1 RAVAS  23 Display  INP 31 DISPLAY 1 RAVAS  24 Indicator board IN 31 N NO ADS 1 RAVAS  25 Bluetooth receiver board EB 31 N BLT DUAL 1 RAVAS  26 Middle cover HOP MC 1 RAVAS  27 Cellrubber block HOP PACK XTRA RU STRIP 1 RAVAS  28 AA battery 1 5V BA 1 5 PENN AA R6 4 Buy locally  29 Contact snap single BAP SNAP SINGLE 2 RAVAS  30 Contact snap dual BAP SNAP DUAL 1 RAVAS             17       24    25  26  27  28  29  30  31    32                               MANUEL D UTILISATION   iForks    5       4  Installation du systeme    4 1 Montage des iForks    Les fourches standard doivent   tre d  mont  es du tablier du chariot  Les iForks sont plac  es sur le tablier  du chariot        V  rouillage des   Forks                MANUEL D UTILISATION   iForks 6    4 2 Installation de l indicateur    Trouver une position appropri  e pour l indicateur     1 sur le toit de la cabine  2 sur le montant droit de la cabine  avec un rail   3  sur le tableau de bord                                     L indicateur doit   tre facile     atteindre et facilement lisible            Installation du bras de l indicateur et du support                                     MANUEL D UTILISATION   iForks 7    4 3 Mettre en place les pack batterie
13. NUEL D UTILISATION   iForks    18                                              6 6 Fonctions de l indicateur      k         9   Sf     Ib   NET a    v Y Y v  PCS   e1 e2 e3 F1 F2  ID CODE PT TOTAL PCS KG LB   x   0  TE WD       2 J A 2 CLR            le syst  me de pesage  charge incluse  est stable  le poids affich   est n  gatif    ZERO    le poids affich   est dans la plage z  ro      1 Le poids affich   est dans la premi  re plage  option multi   chelon     e2 le poids affich   est dans la deuxi  me plage  option multi   chelon     e2    le poids affich   est dans la troisi  me plage  option multi   chelon     F1 Fourche 1   le point de consigne 1 est activ    option sortie relais     DEN  NET    l affichage montre le poids net  Y  Y  Y  Y  Y    F2 Fourche 2   le point de consigne 2 est activ    option sortie relais   kg Poids affich   en kilogrammes   Ib Poids affich   en livres    pcs Le nombre affich   repr  sente le nombre de pi  ces sur le syst  me                  Indicateur de batterie faible  Ji                MANUEL D UTILISATION   iForks 19    Fonctions des touches    Chaque touche a deux fonctions op  rationnelles et une fonction d entr  e             Fonction standard Touche Fonction sp  ciale Fonction d entr  e   appui bref sur touche   appui long sur touche   mode entr  e   ID CODE  Mise    Z  ro Entr  e de code  Entrer  PT    Tare automatique Pr  s  lection de tare    D  cr  menter la valeur  du digit clignotant                Impression du poids et TOTAL V
14. batteries dans les iForks 8  4 5 Mettre les iF  rks en marche 8  4 6 Mettre l indicateur en marche 9  4 7 Eteindre le syst  me 9  5  Remplacer les batteries 10  5 1 Indication de batterie faible sur les IForks 10  5 2 Remplacer les pack batteries des iForks  5 3 Remplacer les batteries de l indicateur 13  6  Utilisation 14  6 1 Utilisation  pesage pr  cis  14  6 1 1 V  rifier le z  ro avant de peser 14  6 2 Correction de niveau  option  15  6 3 Etablir la communication Bluetooth et peser   16  6 4 Coupure automatique de l indicateur 17  6 5 Coupure automatique des   Forks 18  6 6 Fonctions de l indicateur 19  6 7 Messages d erreur 21  6 8 Poids brut tare net 22  6 8 1 Pesage net   tare automatique 22  6 8 2 Pesage net   tare manuelle PT 24  6 9 Totalisation et remise    z  ro de la m  moire de totalisation 27  6 10 Passage KG LB 29  6 11 Param  tres d utilisation 30             MANUEL D UTILISATION   iForks 3          1  Introduction    Ce manuel d  crit l installation et l utilisation des IF  rKS  Lisez ce manuel soigneusement  L installateur doit    tre au courant du contenu de ce manuel  Suivez le contenu du manuel avec pr  cision  Faites toujours  les choses dans l ordre indiqu    Ce manuel devrait   tre gard   dans un lieu s  curis   et sec    Dans le cas o   ce manuel est d  t  rior   ou perdu  l utilisateur peut en demander une nouvelle copie     2  Avertissements et mesures de pr  caution       Quand vous utilisez les   Forks  observez soigneusement les instructions  
15. et directives contenues dans ce manuel  Ex  cutez toujours chaque   tape  dans l ordre  Si l une des instructions n est pas claire  contactez RAVAS       Tous les r  glements de s  curit   qui s appliquent au chariot demeurent valides et inchang  s      Aucun pesage n est autoris   si une personne ou un objet est    proximit   ou aux alentours de la  charge       RAVAS n est pas responsable d un mal physique fait    l op  rateur en raison de la pr  sence de  l indicateur dans la cabine      Toutes les modifications faites sur le chariot doivent   tre approuv  es par un   crit du fournisseur   avant que n importe quel travail soit accompli                    la seule responsabilit   de l acheteur de former ses propres employ  s    l utilisation et  l entretien de cet   quipement      N utilisez pas cet appareil    moins d avoir   t   compl  tement inform   de ses possibilit  s      V  rifiez l exactitude du syst  me de fa  on r  guli  re pour emp  cher les lectures d  fectueuses                  personnel qualifi   et autoris   peut entretenir le syst  me      Suivez toujours les instructions d utilisation  d entretien et de r  paration du chariot et demandez  au fournisseur quand il y a un doute      RAVAS n est pas responsable des erreurs qui se produisent en raison de pesages incorrects ou  de syst  mes impr  cis     min  10  C max 40  C  15  F 105  F    o 0 x       IP65 i  lt          MANUEL D UTILISATION   iForks 4       3     Vue   clat  e et liste des pi  ces           
16. indicateur est vide  La batterie de la fourche 1 est vide    La batterie de la fourche 2 est vide    MESSAGES A l AFFICHAGE    Affichage    Signification  Liaison bluetooth fourche 1   tablie    Action corrective   Automatique   Automatique apr  s retrait du poids  Automatique   appuyer sur n importe quelle touche  Appuyer sur n importe quelle touche  Automatique apr  s correction de l entr  e  Automatique   Automatique   Automatique    Automatique   Quand il y a une action  installer le jumper JP1   attention   apr  s cette action il est n  cessaire  de refaire un   talonnage complet et de poser  de nouveaux scell  s    Automatique    Automatique   Red  marrer indicateur  Red  marrer fourches   amp  indicateur   Red  marrer indicateur  Red  marrer fourches  amp    indicateur   Soulever les fourches du sol    Mettre les fourches    l horizontale    Contacter le SAV RAVAS    Remplacer les 4 piles AA   Replacer les accumulateurs dans les deux  packs batteries ou charger les deux packs  batteries   Replacer les accumulateurs dans les deux  packs batteries ou charger les deux packs  batteries       Pas d erreur       Liaison bluetooth fourche 2   tablie     Pas d erreur    MANUEL D UTILISATION   iForks 21             6 8 Poids net Tare Brut    EXPLICATION  Net 1    Tare 2    Brut 3     N    1        6 8 1 Pesage net   tare automatique                                                                                                                110      x  A     4              Ei 
17. mmence    clignoter  Quand  l indication Low bat commence     clignoter lors de l impression  option  il  faut remplacer les batteries     M6    Utiliser une cl   M6 pour d  visser les  vis du boitier de l indicateur           El    Ouvrir le bo  tier de  l indicateur et enlever les    piles usag  es            ios  WWW    Placer les    nouvelles piles     Assurez vous s  n D  qu elles soient S6  plac  es    correctement   Attention    la  polarit                Fermer le boitier d indicateur et revisser  les vis avec une cl   M6           MANUEL D UTILISATION   iForks    13          6  Utilisation    6 1    Utilisation  pesage pr  cis           3 5min        M1                                                                                                    Ns          Apr  s 3    5 minutes les capteurs ont atteint la  temp  rature d utilisation  Ne soulevez pas de  charge avant d avoir fait une correction du    z  ro                                                                                       P    O  S    1    EE                      ar    om li L            MA n      p  O  AL    1 N  N    N y                          Tp                                       Im                                                                                                                                         min  10  C  15  F    H          105  F       max 40  C                      MANUEL D UTILISATION   iForks    14       6 1 1 V  rifier le z  ro avant de peser               
18. mmencera    clignoter tr  s lentement  deux fois toutes les 10  secondes   Les iF  rks vont s   teindre automatiquement apr  s 10 minutes                 NET v Y O      el e2 e3 F1 F2    1D CODE PT TOTAL PCS KG LB S                 T        lt    d            Nue    2  v     CLR                                           FONCTIONNALITE DE LA LED BLEUE  PENDANT LA MISE SOUS TENSION   ON pendant 5 sec                    BATTERIE PLEINE Intervalle de temps de  clignotement   Mode travail Une fois toutes les 1 5 sec    Mode veille Une fois toutes les 4 sec        BATTERIE FAIBLE  Mode travail Deux fois toutes les 10 sec   Mode veille Deux fois toutes les 10 sec                                MANUEL D UTILISATION   iForks 10       5 2    5 2 1    5 2 2       Remplacer les packs batteries des iForks    Enlever les deux packs batteries                             Changer les piles des packs batteries     1 Enlever les 6 vis M3 X 25    t  te Philips  2 Enlever le logement sup  rieur du pack batterie  3 Enlever les piles                                                                MANUEL D UTILISATION   iForks    11          5 2 3 Placez 4 piles dans chaque pack batterie  Replacez le logement sup  rieur du pack et revissez  les 6 vis M3 x 25    t  te Philips  ne pas forcer          MT    M    f                                                               Ww    ff                               5 24 Remettre en place les packs batteries des iFOrKS  voir 4 3  page 8     5 2 5          
19. s dans les   Forks    Soulevez vers le haut les agrafes de fermeture sur les supports de batterie   Placez les packs batteries dans les deux fourches    Clipsez les packs batteries dans les supports de batterie    Abaissez les agrafes de fermeture pour fixer les packs batterie      0 ae                                    D       2  Les LED bleus des   Forks  vont commencer    clignoter  automatiquement    1  Mettre les fourches en marche  en appuyant sur les boutons  bleus des 2 packs batteries              MANUEL D UTILISATION   iForks 8          4 5 Mettre l indicateur en marche                               D  marrer  l indicateur    Appuyer sur la  touche on off                                  ID CODE                      Pesez         4 6 Eteindre le syst  me                          NET  l i 2 e3 Fi F2         pH  gt     O H 1                Eteindre l indicateur en  appuyant 3 secondes sur la  touche on off                   T                      e A    Eteindre les fourches en appuyant sur les  boutons bleus pendant 8 secondes                MANUEL D UTILISATION   iForks    9    5  Remplacer les batteries   5 1 Indication de batterie faible sur les   Forks   Alimentation des   Forks par pack batterie   changeable    Quand le niveau de tension des pack batteries baisse  l indication de batterie faible s allumera et le  curseur de la fourche concern  e      F1        F2   ou les deux   commencera    clignoter    l affichage     La LED bleue de la fourche concern  e co
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
基礎・基本  GIOVANI COSTRUTTORI DI UN MONDO  General Purpose Thermal Mass Flowmeters TSI Series 4000/4100  SoftBank 202Z 取扱説明書  Amersham™ ECL™ Gel System Compatibility Guide  Es Manual del Usuario Ver. 4.4  取扱説明書/460KB    Christie Vive Audio BKS  SI-912 i-001R1/SI-912-016R6/SI-914    Copyright © All rights reserved. 
   Failed to retrieve file