Home

RP-050 manual de instrucciones / user`s manual / manuel d`utilisation

image

Contents

1. A SAT Recelver Figure 3 SAT receiver test Connect jack 1 RECEIVER to the RP 050 with the IF input jack SAT antenna input of the SAT receiver to be tested Connect SAT receiver and television set SCART socket or RF connector Switch on SAT receiver and television set in case of connection via SCART socket switch television set to the AV channel In case of connection via RF connector tune SAT receiver to television set with the help of the internal receiver pattern Switch on RP 050 slide attenuation selector switch 2 to LOW mode or HIGH mode Tune on the SAT receiver one pilot IF frequency 1050 MHz 1575 MHz or 2100 MHz on L band On the television set there must be visible a picture with two black and one white bar If in addition the SAT receiver is tuned in the audio stage to 7 02 MHz 0 2 MHz a tone of approximately 1 kHz will be audible in the TV set Consequently the video and audio stage of the SAT receiver can be checked 09 03 9 RP 050 09 03 10 RP 050 4 MAINTENANCE The method of maintenance to be carried out by the user consists of cleaning the cover All other operations should be carried out by authorised agents or by personnel qualified in the service of instruments 4 1 Cleaning recommendations CAUTION Do not use scented hydrocarbons or chlorides solvents Such products may attack the materials used in the construction of t
2. Consecuentemente se podr comprobar la correcta ecualizaci n del tramo de instalaci n seleccionado NOTA IMPORTANTE Las portadoras de v deo que genera el RP 050 est n moduladas en FM la carta de barras que se transmite en la banda UHF 525 MHz NO SE VISUALIZARA en la pantalla de un receptor de TV medidor de campo puesto que en banda Terrestre estos aparatos s lo demodulan se ales moduladas en AM Es posible verificar el nivel de la se al piloto mediante el medidor de campo en modo analizador de ESPECTRO NOTA La activaci n del atenuador 2 aparte de afectar al nivel de salida de las portadoras puede provocar un peque o desplazamiento en las frecuencias de sinton a lt 1 A fin de compensar este desplazamiento conviene sintonizar de nuevo el medidor de se al cada vez que se conmute el selector 2 entre la posici n LOW y HIGH 09 03 8 RP 050 3 2 2 Test del receptor SAT Receptor SAT 6 Figura 3 Test de Receptor SAT Conectar el RP 050 al receptor SAT mediante el conector IF OUTPUT 1 y la entrada de FI entrada de antena SAT del receptor SAT que se desea comprobar Conectar el receptor SAT al aparato de televisi n utilizando para ello el conector SCART o bien el conector de RF del televisor Encender el receptor SAT y el aparato de televisi n En el caso de utilizar un conector SCART seleccionar en el televisor un canal AV Si la conexi n
3. 110 dB reference level Verify on the TV level meter screen the presence of the three pilot frequencies generated by the RP 050 as well as the received signal level to evaluate the attenuation value from line Tune on the level meter a pilot IF frequency 1050 MHz 1575 MHz or 2100 MHz on L band On the level meter screen on TV mode there must be visible a picture with two black and one white bar See IMPORTANT REMARK 09 03 RP 050 If in addition the level meter sound is tuned to 7 02 MHz 0 2 MHz a tone of approximately 1 kHz will be audible in the TV level meter Consequently the correct equalisation of the selected installation section will be able to be verified IMPORTANT REMARK Video carriers generated by RP 050 are FM modulated therefore the picture withs bars transmitted at UHF band 525 MHz WILL NOT BE VISUALIZED on TV receiver nor TV level meter since in Terrestrial band these equipments only demodulate AM signals It is possible to verify the pilot signal level using the SPECTRUM analyser mode on a TV level meter REMARK The activation of the altennuator 2 aside from affecting the video carriers output level could cause a small offset on the tuned frequencies lt 1 In order to compensate this frequency offset you are recommended to tune the TV level meter again whenever the selector switch 2 changes between the LOW and HIGH position 09 03 8 RP 050 3 2 2 SAT receiver test
4. W x 85 H x 28 mm D Weight 1509 INCLUDED ACCESSORIES AL 013 External DC adapter AD 060 F m BNC m adapter OPTIONAL ACCESSORIES CC 030 F m F m coaxial cable AD 058 F m quick adapter AL 032 230 V UK mains adapter 09 03 2 RP 050 2 SAFETY RULES Use this equipment connected only to devices or systems with their common at ground potential This equipment can be used in CATEGORY 1 installations and Pollution Degree 2 environments Use this instrument under the specified environmental conditions Follow the cleaning instructions described in the Maintenance Paragraph 09 03 3 RP 050 09 03 4 RP 050 3 OPERATING INSTRUCTION 3 1 Description of the controls and elements RP 050 IF SIMULATOR H Rx v 9 5 kHz 13 V 18 V DC INPUT IF OUTPUT Figure 1 Front view 1 IF OUTPUT Output connector Frequency pilots output On receiver Test mode this jack will be connected with the IF input jack SAT antenna input of the SAT Receiver 2 OFF LOW HIGH Power attenuation mode switch With this switch different attenuation modes of the RP 050 can be selected OFF Power off LOW Output level 90 dBuV HIGH Output level 105 dBuV 09 03 5 RP 050 3 4 5 H 18V Red LED for 18 V This LED will be illuminated if on the coaxial line is present 18 V supply voltage If in addition 22 kHz switching signal is superimposed on the 18 V
5. entre el receptor SAT y el televisor se efect a mediante un conector de RF debe sintonizarse el receptor SAT al aparato de televisi n con la ayuda de la carta interna del receptor Seleccionar en el RP 050 un nivel de salida bajo LOW o alto HIGH mediante el interruptor selector de atenuaci n 2 Sintonizar una de las frecuencias piloto para banda L FI 1050 MHz 1575 MHz o 2100 MHz en el receptor SAT En el aparato de televisi n debe aparecer una carta con dos barras negras y una blanca Si adem s el receptor SAT est sintonizado 7 02 MHz 0 2 MHz un tono de aproximadamente 1 kHz se podr o r mediante el aparato de televisi n Consecuentemente se podr comprobar el funcionamiento de v deo y audio del receptor de sat lite 09 03 9 RP 050 09 03 10 RP 050 09 03 11 5 050 4 MANTENIMIENTO El mantenimiento normal a efectuar por el usuario consiste en la limpieza de la caja Todas las dem s operaciones deber n ser efectuadas por personal especializado en el servicio de instrumentos 4 1 Recomendaciones de limpieza PRECAUCION No use para la limpieza hidrocarburos arom ticos disolventes clorados Estos productos pueden atacar a los materiales utilizados la construcci n de la caja La caja se limpiar con una ligera soluci n de detergente con agua y aplicada mediante un pa o suave Secar completamente antes de volver a usar el equipo 09 03 12 2 RP 050 T
6. supply voltage this LED will flash V 13V Green LED for 13 V This LED will be illuminated if on the coaxial line is present a 13 V supply voltage If in addition a 22 kHz switching signal is superimposed on the 13 V supply voltage this LED will flash DC INPUT DC power supply adapter jack Jack to connect external DC power supply 13 18 V 120 mA 3 2 Operating Instructions 3 2 1 Using combined with a TV level meter The RP 050 has been specially designed for using joint to PROMAX s TV level meters which are able to tune the Satellite band like PROLINK 4 4C Premium PROLINK 3 3C Premium or MC 377 1 MC 377 including the OP 377 63 option 09 03 6 RP 050 1 2 3 4 5 6 MAIN VIDEO SIGNAL DISTRIBUTION PANEL Figure 2 Checking a TV SAT UHF installation Separate the installation section that is desired to check from the general panel or from one of the jack outlets of the TV signal distribution network Connect the RP 050 OUTPUT 1 connector to one of the ends from section under test and use the TV level meter RF input on the other Select on RP 050 depending on the presence of amplifiers in the line an output level LOW or HIGH by means of the attenuation selector switch 2 Turns on the level meter to select the representation of the spectrum in the whole band Full Span and fix as maximum
7. 0 Indicacion de tension y sefial de 22 kHz 13 V se ilumina el LED verde 13 V 22 kHz LED verde intermitente 18 V se ilumina el LED rojo 18 V 22 kHz LED rojo intermitente Tipo de conector F Hembra entrada salida Alimentacion 13 18 120 mA mediante cable RF o fuente DC externa Consumo equipo 3W Condiciones ambientales Altitud hasta 2000 m Margen de temperaturas de 5 C a 40 C Humedad relativa maxima 80 hasta 31 C decreciendo linealmente hasta el 50 a 40 C Caracteristicas mecanicas Dimensiones 77 x Al 85 x Pr 28 mm Peso 150 9 ACCESORIOS INCLUIDOS AL 013 Adaptador DC externo AD 060 Adaptador F m BNC m ACCESORIOS OPCIONALES CC 030 Cable coaxial F m F m 1 AD 058 Adaptador r pido F m F h AL 032 Adaptador red 230 V UK 09 03 2 RP 050 2 PRESCRIPCIONES DE SEGURIDAD A Utilizar el equipo solamente en sistemas con el negativo de medida conectado al potencial de tierra Utilizar el equipo en instalaciones con Categoria de Sobretension ambientes con Grado de Polucion 2 Observar en todo momento las condiciones ambientales maximas especificadas para el aparato Seguir estrictamente las recomendaciones de limpieza que se describen en el apartado Mantenimiento 09 03 3 RP 050 09 03 4 RP 050 3 INSTRUCCIONES DE USO 3 1 Descripci n de los mandos y elementos RP 050 IF SIMULATOR Rx v 9 5 kHz 13 V 18 V DC INPUT IF OUTP
8. 9 03 4 RP 050 3 MODE D EMPLOI 3 1 Description des commandes et des l ments RP 050 IF SIMULATOR Rx DC INPUT IF OUTPUT 22kH2 18 Figure 1 Vue frontale 1 IF OUTPUT Connecteur de sortie Sortie des signales pilotes et connecteur vers l entr e de FI entr e d antenne SAT du r cepteur SAT en mode Test du R cepteur 2 OFF LOW HIGH Commutateur principal S lecteur d att nuation Interrupteur pour s lectionner les diff rents modes d att nuation du RP 050 On SS LL OFF D branchement de l appareil LOW Niveau de sortie de 90 dBuV HIGH Niveau de sortie de 105 dBuV 09 03 5 RP 050 3 H 18V LED rouge indicateur de 18 V Ce LED s allume si dans la ligne coaxiale il y 18 d alimentation Si en outre un signal carr de 22 kHz se superpose aux 18 V d alimentation le LED clignote 4 V 13V LED vert indicateur de 13 V Ce LED s allume si dans la ligne coaxiale il y a 13 V d alimentation Si en outre un signal carr de 22 KHz se superpose aux 13 d alimentation le LED clignote 5 DC INPUT Connecteur d alimentation CC externe Connecteur pour alimenter l appareil au travers d une source d alimentation CC externe 13 18 120mA 3 2 Instructions d operation 3 2 1 Utilisation avec un mesureur pour TV Le RP 050 t pour l utilisation conjointe avec une mesureur de champ PROMAX qui peut syntoniser
9. ABLE OF CONTENTS 1 GENERAL INFORMATION 1 1 1 Description 1 2 Specifications LESA REIR UE 3 3 OPERATING INSTRUCTION 3 1 Description of the controls and elements 3 2 Operating Instructions 3 2 1 Using combined with a TV level mete 3 2 2 SAT receiver test 4 MAINTENANCE 4 1 Cleaning recommendations 09 03 RP 050 09 03 RP 050 SATELLITE RECEIVER amp CABLE TESTER RP 050 1 GENERAL INFORMATION 1 1 Description The RP 050 is a handy versatile and easy to use signal generator with which satellite receivers and coaxial cables of buildings can be checked 1 2 Specifications RECEIVER TEST MODE Frequency Video carriers FM IF L Band 1050 MHz 1575 MHz and 2100 MHz UHF Band 525 MHz Accuracy 1 Level Low mode 90 dBuV 4 dB High mode 105 dBuV 4 dB Audio subcarriers 7 02 MHz 0 2 MHz Modulation FM Audio Approx 1 kHz Video 2 black 1 white bars Voltage and 22 kHz indication 13 V green LED illuminated 13 22 kHz green LED flashes 18 V red LED illuminated 18 V 22 kHz red LED flashes 09 03 1 RP 050 Connector F female input output Power supply 13 18 120 by means of RF cable or external DC supply Equipment consumption 3W Environmental operating conditions Altitude up to 2000 m Temperature range from 5 C to 40 C Maximum relative humidity 80 up to 31 C decreasing lineally up to 50 at 40 C Mechanical features Dimensions 77
10. MANUAL DE INSTRUCCIONES USER S MANUAL MANUEL D UTILISATION COMPROBADOR DE RECEPTORES Y CABLEADO SATELLITE RECEIVER amp CABLE TESTER VERIFICATEUR DE RECEPTEURS ET CABLES RP 050 0 MI1040 NOTAS SOBRE SEGURIDAD Antes de manipular el equipo leer el manual de instrucciones y muy especialmente el apartado PRESCRIPCIONES DE SEGURIDAD El s mbolo sobre el equipo significa CONSULTAR EL MANUAL DE INSTRUCCIONES En este manual puede aparecer tambi n como s mbolo de advertencia o precauci n Recuadros de ADVERTENCIAS Y PRECAUCIONES pueden aparecer a lo largo de este manual para evitar riesgos de accidentes a personas o da os al equipo u otras propiedades SAFETY NOTES Read the instruction manual before using the equipment mainly SAFETY RULES paragraph The symbol DA on the equipment means SEE USER S MANUAL In this manual may also appear as a Caution or Warning symbol Warning and Caution statements may appear in this manual to avoid injury hazard or damage to this product or other property REMARQUES PROPOS DE LA S CURIT Avant manipuler l appareil lire le manuel d utilisation et plus particuli rement le paragraphe PRESCRIPTIONS DE SECURITE Le symbole DA sur l appareil signifie CONSULTER LE MANUEL D UTILISATION Dans ce manuel il peut galement apparaitre comme symbole d avertissement ou de pr caution Des encadr s AVERTISSEMENTS ET PR CAUTIONS peuvent apparaitre dans ce man
11. UCI N SE AL TV ENTRADA RF MEDIDOR DE SE AL TV TOMA TV o jo o Figura 2 Comprobaci n de una instalaci n de TV SAT UHF Separar el tramo de instalaci n que se desea comprobar a partir del panel general o una de las tomas de distribuci n de la se al de TV Conectar el RP 050 a uno de los extremos del tramo a verificar mediante el conector OUTPUT 1 y conectar el medidor de se al de TV entrada RF en el otro Seleccionar en el RP 050 dependiendo de la presencia de amplificadores en la l nea un nivel de salida bajo LOW o alto HIGH mediante el interruptor selector de atenuaci n 2 Encender el medidor de seleccionar la representaci n del espectro en toda la banda Full Span y fijar un nivel de referencia m ximo de 110 dB Comprobar en la pantalla del medidor de se al de TV la presencia de las tres frecuencias piloto generadas por el RP 050 as como el nivel de se al recibido para valorar la atenuaci n de la l nea 09 03 gt 8 050 6 Sintonizar una de las frecuencias piloto para banda L Fl 1050 MHz 1575 MHz 2100 MHz en el medidor de se al En el medidor se al en modo TV debe aparecer una carta con dos barras negras y una blanca ver NOTA Si ademas el sonido del medidor esta sintonizado 7 02 MHz 0 2 un tono de aproximadamente 1 kHz se podra oir a trav s del altavoz
12. UT Figura 1 Vista frontal 1 IF OUTPUT Conector de salida Salida de se ales piloto y conector para la entrada de Fl entrada de antena SAT del receptor SAT en el modo Test del Receptor 2 OFF LOW HIGH Interruptor general selector de atenuaci n Interruptor para seleccionar los diferentes modos de atenuaci n del RP 050 09 03 5 RP 050 OFF Desconexi n equipo LOW Nivel de salida de 90 dBuV HIGH Nivel de salida de 105 dBuV 3 18 V LED rojo indicador de 18 V Este LED se ilumina si en la linea coaxial esta presente una tensi n de alimentaci n de 18 V Si adem s una se al cuadrada de 22 kHz se superpone a los 18 V de alimentaci n el LED parpadea 4 13 LED verde indicador de 13 V Este LED se ilumina si en la l nea coaxial est presente una tensi n de alimentaci n de 13 V Si adem s la se al cuadrada de 22 kHz se superpone a la tensi n de alimentaci n de 13 V el LED parpadea 5 DC INPUT Conector para alimentador DC Conector para alimentar el instrumento mediante fuente DC externa 13 18 V 120 mA 3 2 Instrucciones de operaci n 3 2 1 Utilizaci n con un medidor de campo El RP 050 ha sido dise ado para la utilizaci n conjunta con un medidor de campo PROMAX que sintonice la banda Sat lite en especial los medidores PROLINK 4 4C Premium PROLINK 3 3C Premium 377 1 MC 377 con la opci n OP 377 63 09 03 6 RP 050 CUADRO DISTRIB
13. V 7 02 MHz 0 2 MHz 1 kHz env Carte a 2 barres noires et une blanche RP 050 202 On LL Indication de tension et signal de 22 kHz 13 le LED vert s allume 13 V 22 kHz le LED vert clignote 18 le LED rouge s allume 18 V 22 kHz le LED rouge clignote Type de connecteur F Femelle entr e sortie Alimentation 13 18 V 120 mA au travers du c ble RF ou source CC externe Consommation 3W Conditions d environnement Altitude jusqu 2000 m tres Marge de temp ratures de 5 C 40 C Humidit relative maximale 80 jusqu 31 C diminution lin aire jusqu 50 40 C Caract ristiques m caniques Encombrement 77 mm x L 85 mm x P 28 mm Poids 150 g ACCESSOIRES INCLUS AL 013 Adaptateur CC externe AD 060 Adaptateur F m BNC m ACCESSOIRES OPTIONNELS CC 030 Cable coaxial F m F m AD 058 Adaptateur rapide F m F f AL 032 Adaptateur s cteur 230 V RU 09 03 5215 RP 050 2 PRESCRIPTIONS DE SECURITE N utiliser l quipement que sur des syst mes dont le n gatif de mesure est connect au potentiel de terre Cet appareil peut tre utilis sur des installations de la Cat gorie Surtension et Degr de Pollution 2 Observer toujours les conditions ambiantes maximales sp cifi es pour cet appareil Suivez strictement les recommandations de nettoyage d crites au paragraphe Entretien 09 03 3 RP 050 202 On LL 0
14. age ne pas employer d hydrocarbures aromatiques ou des solvants chlor s Ces produits peuvent attaquer les mati res utilis es dans la construction du bo tier Nettoyez la bo tier avec une solution faible de d tersif l eau appliqu e avec un chiffon doux S cher compl tement avant d utiliser l appareil de nouveau 202 On LL 09 03 11 050 PROMAX ELECTRONICA S A Francesc Moragas 71 Apartado 118 08907 L HOSPITALET DE LLOBREGAT SPAIN Tel 93 260 20 00 Tel intl 34 93 260 20 02 Fax 93 338 11 26 Fax intl 34 93 338 11 26 http www promax es
15. es noires et une blanche doit apparaitre Voir REMARQUE IMPORTANTE Si en outre le son du mesureur est syntonis a 7 02 MHz 0 2 MHz un ton approximativement de 1 kHz pourra tre entendu a travers le haut parleur On pourra cons quemment v rifier l galisation correcte de la section d installation choisi REMARQUE IMPORTANTE Les porteuses vid o que produit le RP 050 sont modul es en FM la carte barres qui est transmise dans la bande UHF 525 MHz NE SERA PAS VISUALIS E sur l cran d un t l viseur ou d un mesureur de niveau puisqu en bande Terrestre ces appareils d modulent seulement des signaux modul es en AM ll est possible de v rifier le niveau du signal pilote au moyen du mesureur de niveau dans le mode analyseur de SPECTRES REMARQUE L activation de l attenuateur 2 en plus d affecter le niveau de sortie des porteuses vid o peut aussi provoquer un petit d placement dans les fr quences de syntonie lt 1 Afin de compenser ce d placement il convient de syntoniser de nouveau le mesureur de signal chaque fois quan change la position du s lecteur d att nuation 2 09 03 8 RP 050 3 2 2 Test du r cepteur SAT 7 R cepteur SAT ea Figure 3 Test du R cepteur SAT Connecter le RP 050 au r cepteur SAT au moyen du connecteur Receiver 1 et de l entr e de Fl entr e d antenne SAT du r cepteur SAT que souhaite v rifier Connecter le r cep
16. he cover The cover should be cleaned by means of a light solution of detergent and water applied with a soft cloth Dry thoroughly before using the system again 09 03 H RP 050 09 03 12 RP 050 SOMMAIRE 1 GENERALITES 1 1 Description 1 2 SPOciticatiOns cir 1 2 PRESCRIPTIONS DE S CURIT 3 MOBE D EMPLOL 4 5 3 1 Description des commandes et des l ments 5 3 2 Instructions d op ration 6 3 2 1 Utilisation avec un mesureur pour TV 7 3 2 1 Test du recepteur SAT 9 4 5 52595596 55 11 4 1 Recommandations de 11 09 03 RP 050 202 On LL 09 03 RP 050 VERIFICATEUR DE RECEPTEURS ET CABLES RP 050 1 GENERALITES 1 1 Description Le RP 050 est un g n rateur de signaux pratique versatile et tres facile a manier il permet une v rification efficace du fonctionnement correct de r cepteurs satellite ainsi que des cables coaxiaux dans batiments 1 2 Sp cifications MODE TEST RECEPTEUR Fr quences Porteuses vid o FM Bande L Bande Pr cision Niveau mode Low mode High Sous porteuse audio Modulation FM Audio Vid o 09 03 1050 MHz 1575 MHz et 2100 MHz 525 MHz 1 90 4 dBuV 105 4 dBu
17. la bande Satellite sp cialement les mesureurs PROLINK 4 4C Premium PROLINK 3 3C Premium ou MC 377 1 377 avec OP 377 63 09 03 6 RP 050 ENTREE RF MESUREUR DE SIGNAL DE TV Figure 2 V rification d une installation de signal de SAT UHF 12 S parer la section d installation qu on souhaite v rifier a partir du panneau g n ral ou d une des prises de distribution du signal de TV Relier le RP 050 a une des extr mit s de la section a v rifier au moyen du connecteur OUTPUT 1 et brancher le mesureur du niveau du signal de TV entr e RF dans l autre Choisir dans le RP 050 selon la pr sence d amplificateurs dans la ligne un niveau de sortie bas LOW ou haute HIGH au moyen de l interrupteur s lecteur d att nuation 2 Mettre en marche le mesureur de niveau choisir la repr sentation du spectre dans toute la bande Full Span et fixer un niveau de r f rence maximal de 110 dB V rifier sur l cran du mesureur de champ la pr sence des trois fr quences pilotes produites par le RP 050 ainsi que le niveau du signal regu pour valuer l att nuation de la ligne 09 03 RP 050 Or SS LL 6 Syntoniser une des fr quences pilotes pour la bande L Fl 1050 MHz 1575 MHz ou 2100 MHz dans le mesureur du signal Une fois mis en mode TV le mesureur une carte a deux barr
18. teur SAT au poste de t l vision en utilisant pour cela soit le connecteur SCART soit le connecteur RF du t l viseur Enclencher le r cepteur SAT et le poste de t l vision Si un connecteur SCART est utilis s lectionner un canal AV sur le t l viseur Si la connexion entre le r cepteur SAT et le t l viseur est effectu e l aide d un connecteur il faut syntoniser le r cepteur SAT et le poste de t l vision l aide de la carte interne du r cepteur S lectionner un niveau de sortie bas LOW ou haute HIGH sur le 050 l aide de l interrupteur s lecteur d att nuation 2 Syntoniser une des fr quences pilotes de la bande L FI 1050 MHz 1575 MHz ou 2100 MHz sur le r cepteur SAT Une carte deux barres noires et une blanche doit appara tre sur le poste de t l vision Si en outre le r cepteur SAT est syntonis sur 7 02 MHz 0 2 MHz l on pourra entendre sur le poste de t l vision une tonalit d environ 1 kHz Par cons quent l on pourra v rifier le fonctionnement de vid o et d audio du r cepteur de satellite 09 03 9 RP 050 2 On SS LL 09 03 10 RP 050 4 ENTRETIEN L entretien courant ex cuter par l utilisateur revient au nettoyage du bo tier Le reste des op rations sera ex cut par les responsables autoris s ou par du personnel sp cialis dans le service des instruments 4 1 Recommandations de nettoyage PR CAUTION Au nettoy
19. uel pour viter des risques d accidents affectant des personnes ou des dommages l appareil ou d autres biens SUMARIO CONTENTS SOMMAIRE Manual English manual SEE On Ma yel fran ais sieste LL NDICE 1 GENERALIDADES 1 1 Descripci n 1 2 Especificaciones 2 PRESCRIPCIONES DE INSTRUCCIONES DE USO 3 1 Descripci n de los mandos y elementos 3 2 Instrucciones de 6 3 2 1 Utilizaci n con un medidor de ee 8 2 2 Test deliveceplor SAT 4 MANTENIMIENTO 4 1 Recomendaciones de limpieza 09 03 RP 050 09 03 RP 050 COMPROBADOR DE RECEPTORES Y CABLEADO RP 050 1 GENERALIDADES 11 Descripcion El RP 050 es un generador de se ales pr ctico vers til y de muy f cil manejo que permite una eficaz comprobaci n del correcto funcionamiento de instalaciones para recepci n de se ales sat lite y cableados coaxiales en edificios 1 2 Especificaciones A MODO TEST DE RECEPTOR Frecuencias Portadoras de v deo FM Banda L FI 1050 MHz 1575 MHz y 2100 MHz Banda UHF 525 MHz Precision 1 Nivel modo Low 90 dBuV 4 dB modo High 105 dBuV 4 dB Subportadoras audio 7 02 MHz 0 2 MHz Modulacion FM Audio 1 kHz aprox V deo carta de 2 barras negras y una blanca 09 03 1 RP 05

Download Pdf Manuals

image

Related Search

Related Contents

BGD800 BGD801  LA FEMME Deux - 株式会社メイクソフトウェア  Bedienungsanleitung - Vodafone Officenet snom 370  地デジ11チャンネルでコミュニティチャンネルを見るために 1 2 3 4  Tag Reference Manual - Pro  Samsung LE32N73BD Manual de Usuario  A GUIDE TO CONTAINER TREE SEEDLING PRODUCTION  Total Pond LLUV1050 Installation Guide  Sencor SMH 330  Installation and Service Manual  