1. on the ground or on a brickwork base or on the adjustable support or on the ventilation chamber or on a St v base or on the 16 cube base sub unit to form a St v 16 H In the two latter cases see the instructions which come with these accessories Whatever solution is chosen the position of the plate determines the position of the freestanding fireplace It is thus essential to align it accurately with the smoke flue A small hole cut in the sheet metal photo 2 indicates the verticality of the smoke outlet Please bear in mind that the front edge of the plate will stand 5 16 back from flap photo 3 Prepare the base plate according to the configuration chosen See page 7 Consult the instrctions suppled with the accessory St v 16 cube installation en 07 2014 SN 97851 Air drawn from outside If the freestanding fireplace is positioned on a St v base with a drawer or on a St v 16 H base please consult the instructions which come with these accessories The combustion air is drawn from outside by means of a duct diagram 1 connected to the support plate Remove the plug photo 2 and the cover at the front photo 3 Fit the duct over the sleeve photo 4 and secure it with a clamp collar photo 5 with the collar attachment turned towards the back of the freestanding fireplace Insert the 2 M4 screws with hexagonal heads into the cover at the front put the slee
2. 90 number of elbows 4 4 elbows 8 4 elbows 10 2 elbows 12 0 elbow The closure damper photo 4 prevents the house from becoming cold when the free standing fireplace is not in use This system is optional if you choose a connection directly to the free standing fireplace diagrams 1and 2 However it is still a good idea if the ducts are too long to reach the free standing fireplace or if it is being installed in an energy efficient house It should ideally be located as close as possible to the outside wall Caution length of the valve control cable 48 and damper diameter is O 6 Plan to install a reducer If it is not possible to bring in outside air near the free standing fireplace most unfavourable case ensure there is sufficient replenishment of air in the room when the free standing fireplace is in use Caution Be careful with active air extraction systems kitchen hoods air conditioning mechanically controlled ventilation and other free standing fireplaces in operation in the same space or in an adjacent room They also use a lot of air and can cause a depression in the room and prevent the free standing fireplace from operating correctly risk of backdraught They can affect the operation of the free standing fireplace even if it is connected to an outside air inlet Le conduit qui amene l air ext rieur qu il soit connect au foyer ou pas Sera prot g l ext rieu
3. Combustible materials such as firewood wet clothes etc placed too close to the appliance could catch fire Objects placed in front of the fireplace should be kept at a distance of at least 48 1 22m from the glass front Do not let the fireplace heat up until some parts glow red Burn the firewood directly on the refractor plates or the iron Do not use an andiron and do not try in any way to raise the fire Do not install in a mobile home The installation instructions for your wood free standing fireplace are compliant with the ULC S627 et UL 1482 standards They must be strictly followed in order to prevent any risk of major problems Please read carefully this manual before installing or operating your free Ce foyer a t concu pour offrir un maximum de confort et de s curit Le plus grand soin a t apport sa fabrication Si malgr cela vous constatiez une anomalie contactez votre revendeur Nous vous recommandons de lire cette notice avant de proc der l installation Certaines configurations peuvent faire varier quelque peu l ordre des op rations effectuer Normes agr ations et caract ristiques Tol a alle WEZ C US Cet appareil t test et certifi par CSA et selon les normes suivantes UL STD 1482 ULC STD S627 EPA EXEMPT ASTM Instructions de s curit Avant d installer votre St v contactez les autorit s locales en b timent ou le service des incendies et suivez
4. GAGEMENTS BOJ WC 777 V VM Hearth slab Non combustible material Non combustible material Non combustible material Protection de sol i Mat riau non combustible Protection de sol Mat riau non combustible Mat riau non combustible at riau non combustible solide i4 Joqueuo np uonededouad ua uomneJedauJd ous 1 6 cube amp H Combustion air inlet The free standing fireplace requires air for combustion particularly when installed in air tight house The ideal solution The Stuv 16 is designed to be directly connected to an outside air inlet independent of the air in the house We recommend this set up The connection is made below the free standing fireplace diagrams 1 If the free standing fireplace is not connected directly to an outside air inlet optional A sufficient air inlet O 2 1 2 should ideally be created close to the free standing fireplace This air inlet comes from a ventilated empty space a ventilated room cellar or from outside This set up is mandatory in some countries or localities The air inlet adjustment can never be modified Arriv e d air pour la combustion Le foyer a besoin d air pour la combustion particulierement lorsqu il est install dans des maisons tr s tanches La solution id ale Le St v 16 est concu pour tre connect directement une arriv e d air ext rieur ind pendant de l air de la maison Nous recom
5. cube 8 H any Aj Iojdwo p opow 9 uone ejsul Ud 9SN JOJ suonpauip UOHREJ EJSUI en Technical specifications Site preparation Installation Directions for use Product registration and contact 4 8 9 14 15 30 31 57 98 61 fr Pr sentation du produit Pr paration du chantier Installation Mode d emploi Enregistrement et contact 4 8 9 14 15 30 31 97 58 61 Your tireplace was designed to provide years of enjoyment comfort and satety lt was built and assembled with the greatest care If tor any reason you are dissatisfied with your fireplace please contact your retailer We recommend that you read the instructions before proceeding with the installation With certain configurations the sequence of operations to be performed may slightly vary Standards certifications and technical specifications C US This appliance has been tested and certified by CSA based on the following standards UL STD 1482 ULC STD S627 EPA EXEMPT ASTM Safety instructions Before installing your St v please contact the local building authorities or the fire department and follow their directives The installation of your St v should be entrusted to a skilled professional If the St v fireplace is not properly installed a fire could result Your Stuv can be very hot children and domestic animals should not touch the fireplace when operating
6. leurs directives L installation de votre St v doit tre confi e un professionnel qualifi Si votre St v n est pas install de facon ad quate un incendie pourrait s ensuivre Votre St v peut devenir tr s chaud il faut emp cher les enfants et les animaux domestiques de toucher le foyer lorsqu il fonctionne Les mat riaux combustibles tels que le bois de chauffage les v tements mouill s etc plac s trop pr s de l appareil pourraient prendre feu Les objets plac s devant l appareil doivent tre gard s une distance d au moins 48 de la face vitr e de l appareil Ne laissez pas le foyer chauffer au point o des parties deviennent rougeoyantes Br lez le bois de chauffage directement sur les briques r fractaires ou la fonte N utilisez pas de chenet et n essayez pas de sur lever le feu de quelque facon Ne pas installer dans une maison mobile Les instructions concernant l installation de votre po le d ambiance bois sont conformes aux normes ULC S627 et UL 1482 Vous devez les suivre rigoureusement afin d liminer tout risque d ennuis majeurs Veuillez lire attentivement ce manuel avant d installer ou standing fireplace If your free standing fireplace is incorrectly installed a fire might result which would destroy your house To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Consult your
7. local authorities or your insurance company regarding all applicable regulatory requirements to obtain a permit and to install your fireplace Installation must comply with CAN CSA B365 code Keep this manual handy so you may refer to it whenever necessary CAUTION e DO NOT USE CHEMICALS OR FLUIDS TO LIGHT THE FIRE e DO NOT LEAVE THE FREE STANDING FIREPLACE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED e ALWAYS CLOSE THE DOOR AFTER THE IGNITION e DO NOT BURN GARBAGE FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL e DO NOT CONNECT THE FREE STANDING FIREPLACE TO ANY HOT AIR DISTRIBUTION SYSTEM e HOT WHILE IN OPERATION KEEP CHILDREN CLOTHIN AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURN Note We strongly recommend that our products be installed and serviced by professionals certified by the Association des Professionnels du Chauffage in Quebec or by Wood Energy Technology Training for the rest of Canada or by the National Fireplace Institute in the U S CHAUFFAGE Wood Energy Technical Training wettinsc FF OFF n d op rer votre po le Si votre po le d ambianceest mal install il peut en r sulter un incendie d truisant votre maison Pour r duire les risques d incendie suivez les instructions d installation Le fait de ne pas respecter les instructions peut occasionner des dommages la propri t des l sions corporelles et m me la mort Consultez le repr sentant de
8. use of this system has to comply with the installer s recommendations and the manufacturer s instructions which are set out in the directions for use issued to the customer with the invoice and this confirmation of acceptance The efficiency and longevity of the system depend directly on the quality of wood used it is essential that wood with humidity of less than 18 or reconstituted wood briquettes are used Green wood with drying out time of less than 24 months cannot be used more information in the fuels section on pages 8 and 9 of the directions for use THE INSTALLATION ENGINEER name written out in full and signature THE CUSTOMER name written out in full and signature L Directions for use of the system issued to customer Information sheet on lighting the freestanding fireplace issued to the customer CONTACTS St v subsidiary in America St v America 4747 rue Bourg H4T1H9 Montr al Qc Canada St v 16 cube installation en 07 2014 SN 97 851 installation instructions St v 16 cube amp Stuv 16H len 07 2014 SN 97951 gt St v reserves the right to make changes without prior notice nl de it es pt cz en fr gt These instructions have been produced with the greatest of care This document is available in several However we do not accept responsibility for any errors that may have been made languages Contact your distri
9. MANUFACTURIER DE CHEMIN E POUR LES D TAILS D INSTALLATION DE LA CHEMIN E PR CAUTIONS Si cet appareil n est pas ad quatement install un incendie peut s ensuivre Afin de r duire tout risque d incendie suivez les instructions d installation Consultez les autorit s locales pour obtenir un permis de construction ainsi que de prendre connaissance de toutes les exigences r glementaires en vigueur Self tapping metal screws 3 Ic 6 Collar Bolts 3 2 1 2 2 1 8 Load bearing capacity of the structure Ensure that the floor is resistant enough to support the free standing fireplace consult a specialist if in doubt olace s surroundings The free standinc The heat radiated from the glass door and the unit may be significant Whichever direction the stove is facing please adhere to the safety distances from combustible materials diagram 1 or ensure that the materials exposed to radiate heat are resistant to high temperatures Prevent heat traps in the cladding recess and hood If the free standing fireplace is situated in a bell shaped area e g a former hearth this space must be ventilated to prevent heat traps Opening the door A glove is provided with your fireplace Use it always when manipulating the door opening tool cold hand Always remove and place the cold hand away but close by the fireplace when not using it Never let the cold hand hung in position to the fireplace B
10. ay paint tubes of grease and advise him to return it to the tools manufacturer or importer When the fire is first lit some smoke or odours may be produced Ventilate the room thoroughly 1 8 St v 16 cube installation en 07 2014 SN 97851 Replacement of the glass MA St v 16 58 46298 gt St v 16 78 46306 gt 14006014 N 14006015 N 14006016 1658 glass kit joint S1668 glass kit joint S1678 glass kit joint Replacement of the glass Explications pour le changement de vitre voir photos 1 Ouvrir la vitre 2 D faire le ressort 3 D crocher la porte de son emplacement 4 D visser les serre joints et serre vitre 5 Enlever la vitre endommag e 6 Remplacer par une nouvelle vitre et remonter le tout en sens inverse Il s agit d une vitre c ramique de 4mm d paisseur Les joints d tanch it ont une paisseur de 8mm Ne pas faire de feu quand la vitre est bris e Nettoyer la vitre froid Eviter absolument les nettoyants abrasifs Le claquage de la porte peut briser la vitre How to change the glass see pictures 1 Open the door 2 Unlock the spring 3 Take the door down from its place 4 Unscrew the gaskets and glass clamps 5 Take the broken glass off 6 Replace with the new glass and put things back together The glass is ceramic of 4mm thickness The gaske
11. butor or visit Editor G rard Pitance rue Jules Borbouse 4 5170 Bois de Villers Belgium www stuv com
12. d with fireplace must be listed See owners manual d paisseur Contact your local building or fire officials about restrictions and installation inspections in your area Do not overfire If stove or chimney connector glows you are overfiring Do not connect this unit to a chimney flue serving another appliance notice d utilisation buildup may occur rapidly votre r gion Do not use grate or elevate fire Build wood fire directly on hearth CAUTION Hot parts Do not operate unit with damper removed or chimney connector through a combustible wall or ceiling and reference to local building code for details fond de l tre Use only a 6 or 7 inch chimney listed per UL 103 HT or ULC S 629 Utiliser uniquement un connecteur double parois noir de 6 ou 7 pouces Utiliser uniquement une chemin e de 6 ou 7 pouces r pertori e selon la Cet appareil peut tre plac directement sur un mat riau combustible R f rez vous au code du batiment local pour le prolongement de l tre Pour un fonctionnement s curitaire installez conform ment aux directives du Remplacez le verre uniquement par un verre de c ramique St v de 4mm Ne pas utiliser l appareil les portes ouvertes et charger seulement feu ouvert Les composantes utilis es dans l appareil doivent tre r pertori es Voir Communiquez avec les autorit s locales en mati re de construction ou Inspect and clean chimney frequently Under c
13. e of the glass Clearance from the bottom of the glass to the floor gt 18 no minimum R value gt 15 18 minimum 1 2 cement board 4 ceramic CLEARANCES MAY ONLY BE REDUCED BY MEANS APPROVED BY THE REGULATORY AUTHORITY We recommend to store solid fuel wood logs in a clean and dry environment Caution do not place such fuel within space heater installation clearanes or within the Space required for charging and ash removal DIMENSIONS amp DEGAGEMENTS Les d gagements indiqu s sont pour tout mat riaux combustible ex Bois Gypse etc D gagement avant 48 D gagement arri re 7 D gagement des c t s 12 D gagement au dessus 24 1 2 Un mat riau de protection incombustible doit tre plac au sol l avant de l appareil sur une longueur de 18 devant la vitre et 6 de chaque c t de la vitre D gagement entre le sol et le bas de la vitre gt 18 pas de valeur R minimale gt 15 18 minimum 12 paneau de fibro ciment 14 c ramique LES D GAGEMENTS PRESCRITS NE PEUVENT ETRES REDUITS QUE PAR DES MOYENS APPROUVES PAR UNE AUTORITE DE REGULATION Nous vous recommandons de ranger le combustible solide bois de corde dans un environnement propre et sec Attention Ne placez pas ce genre de combustible dans lespace de d gagement d instalation du po le dambianceou dans lespace de chargement ou de d cendrage DIMENSIONS amp CLEARANCES DIMENSIONS amp D
14. ertain conditions of use creosote d incendie pour connaitre les restrictions et inspections d installation dans Ne pas chauffer au point ou des parties deviennent rougeoyantes Nereliez pas cet appareil un conduit de chemin e servant un autre appareil z r x x x x Inspectez et nettoyez la chemin e fr quemment Dans certaines conditions Check STUV s installation instructions for precautions required for passing a chimney d utilisation l accumulation de cr osote peut se faire rapidement N utilisez pas de chenet Ne pas sur lever le feu Br lez le bois directement au principales des appareils Type de combustible b ches de bois St v 16 cube amp H Puissance maximale 16 58 40 000 BTU 16 68 43 000 BTU 16 78 46 000 BTU Efficacit 80 donn es europ ennes Type de chemin e Conduit isol 6 ou 7 UL 103HT ULC S629 Connecteur double parois de 6 ou de 7 Poids de l unit 16 58 cube 232 Ibs 16 58 H 300 Ibs 16 68 cube 249 lbs 16 68 H 324 lbs 16 78 cube 267 lbs 16 78 H 348 Ibs Consommation bois h gt 5 kg heure Longueur maximum des b ches l horizontal 16 58 17 16 68 21 16 78 25 Autocollant de marquage Clearances for St v 16 58 16 68 16 78 cube inch Clearance to combustibles l I straight corner thru the wall D gagement aux mati res combustibles SIDE WALL PAROI LAT RALE 12 BACK WALL MUR ARRI RE 7 From stove to side wa
15. estanding fireplace to the support plate h 2 screws for attaching the back of the freestanding fireplace to the support plate i adjustable levelling feet j Installation instructions and directions for use St v 16 cube installation en 07 2014 1 1 SN 97851 Unpacking continuation Before moving the freestanding fireplace Dismantle the door unfasten the resisting spring photo 4 then remove it Lift off the cover remove the 4 screws on either side of the door photo 5 remove the upper part of the cover from the freestanding fireplace To do so release the lock by undoing the hexagonal headed screw photo 6 and turn the lock photo 7 take off the cover using the grips provided photos 8 and 9 Moving the freestanding fireplace using a pallet truck leave it on its pallet using a hand truck insert some cardboard to protect the back of the freestanding fireplace turn the freestanding fireplace onto its back leave the pallet in its position by hand take hold of the freestanding fireplace at the front photo 10 and at the back photo 11 1 2 St v 16 cube installation en 07 2014 SN 97851 The base plate photo 1 is a key element in the system the outside air inlet duct is connected to it and the fan and its accessories are attached to it It supports the freestanding fireplace itself It remains fixed It is positioned
16. ll 12 na 15 From pipe to side wall 24 na From stove to back wall From pipe to back wall From stove to wall corner only From pipe to wall corner only Ceiling from top of stove Floor under the stove 7 pieds de r glage d viss s 3 4 Floor in front of the stove from the bottom of the glass no protection Floor in front of the stove from the bottom of the glass floor protection 1 2 durock 1 4 ceramic ICAUTION ATTENTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS SEE NAME PLATE AND INSTRUCTIONS CHAUD LORSQU EN FONCTION GARDER LES ENFANTS V TEMENTS ET MEUBLES HORS DE PORT E TOUCHER L APPAREIL POURRAIT CAUSER DES BR LURES VOIR LA FICHE SIGNAL TQUE ET INSTRUCTIONS DO NOT REMOVE THIS LABEL NE PAS RETIRER CETTE TIQUETTE Se r f rer au code du b timent et aux instructions ST V avant de traverser le mur ou _ ATTENTION Pi ces chaudes Ne pas faire fonctionner avec le clapet retir le plafond avec votre conduit de chemin e DIMENSIONS amp CLEARANCES The clearances are indicated for all types of combustible materials e g wood gypsum etc Front clearance 48 Rear clearance 7 Side clearance 12 Above clearance 24 1 2 flameproof protective material must be laid on the ground in front of the fireplace over a length of 18 in front of the glass and 6 on each sid
17. mande du clapet 48 et le diam tre du clapet est de 6 Pr voir un r ducteur S il n est pas possible d amener de l air ext rieur proximit du foyer cas le plus d favorable S assurer que le renouvellement d air dans la pi ce sera toujours suffisant quand le foyer est en fonctionnement Note Attention aux syst mes d extraction actifs d air hotte de cuisine air conditionn ventilation m canique contr l e autre foyer situ s dans le m me espace ou dans une pi ce contig e Ils consomment eux aussi beaucoup d air et pourraient cr er une d pression dans le local et perturber le bon fonctionnement du foyer risque de refoulement Ils peuvent perturber le fonctionnement du foyer m me si celui ci est raccord une arriv e d air ext rieur Connection to the chimne Caution Care must be taken during installation Shortcuts or compromises may result in safety hazards or even fire Do not connect the unit to a chimney used for another appliance Do not cut rafters or ceiling joints without first consulting a building official to ensure that structural integrity is not compromised Use a 6 inch clearance double walled connector black Use only a 6 inch or a 7 inch insulated flue in compliance with the UL 103 HT or ULC S629 standard as soon as you go through a combustible wall in compliance with your local installation standards This connector will be fixed to the smoke outlet using 3 self
18. mandons cette disposition La connexion se fait par en dessous du foyer sch mas 1 Si le foyer n est pas directement raccord une arriv e d air ext rieur facultatif Une arriv e d air suffisante 2 1 2 doit id alement d boucher proximit du foyer Cette arriv e d air proviendra d un vide ventil d un local ventil cave ou de l ext rieur Cette disposition est obligatoire dans certains pays ou localit s L ajustement d entr e d air ne doit en aucun cas tre modifi The duct that brings in outside air whether it is connected to the free standing fireplace or not Will be protected on the outside by a grill where the free passage section of which is at least equivalent to the section of the air inlet Please note that the infiltration of water and the effect of the wind can damage the system Will ideally be fitted with a closure valve for example the St v damper see below photo 4 to prevent the room from becoming cold when the free standing fireplace is not in use Will be as short as possible and insulated to prevent pressure loss and to keep the house from getting cold If you use our standard flexible 2 1 2 duct we recommend a maximum length of 78 and no more than 4 elbows see table below If you exceed these guidelines you must compensate with a greater diameter and or a smoother duct Careful not to crush the duct Length of flue Max permitted
19. ney 6 or 7 UL 103HT ULC S629 6 or 7 Double wall connector Unit weight 16 58 cube 232 Ibs 16 58 H 300 Ibs 16 68 cube 249 Ibs 16 68 H 324 Ibs 16 78 cube 267 Ibs 16 78 H 348 Ibs Wood consumed per hour gt 5 kg hour Maximum length of logs in horizontal position 16 58 17 16 68 21 16 78 25 Marking Sticker CERTIFIED AND CONFORMS TO MODELIMODEUE Stuy CERTIFI CONFORM MENT SELON 16 58 cube 16 68 cube 16 78 cube ULC STD S627 8 UL STD 1482 EPA EXEMPT 16 58 H 16 68 H 16 78 H MANUFACTURED BY FABRIQUE PAR NOT SUITABLE FOR MOBILE HOME INSTALLATION STUV S A rue Jules Borbouse 4 Certified for use in Canada and U S A B 5170 Bois de Villers Belgium www stuv com PO LE PR FABRIQU HOMOLOGU NE PAS INSTALLER DANS UNE MAISON MOBILE Usage homologu au Canada et aux U LISTED FACTORY BUILT STOVE LABEL NO NO D TIQUETTE ST V 16 000 000 stay CHIMNEY TYPE Use only a 6 or 7 inches double wall flue pipe connector black TYPE DE CHEMIN E norme UL 103 HT ou ULC S 629 Fuel Wood Only Combustible Bois seulement Unit can be placed directly on combustible material Refer to local building code for heart extension dimensions For safe operation install in accordance with the manufacturer s instructions Replace glass only with Stuv s ceramic glass 4mm thick fabricant Do not operate unit with doors open and load on open fire door Components use
20. r par une grille sch mas 2a 3a dont la section de passage libre est au moins quivalente la section d arriv e d air Attention aux infiltrations d eau et l influence des vents qui peuvent annihiler le syst me Sera id alement quip d un clapet de fermeture par exemple le clapet St v photo 4 pour viter de refroidir la pi ce quand le foyer n est pas en fonctionnement Sera le plus court possible et isol pour viter des pertes de charges et pour ne pas refroidir la maison Si vous utilisez notre conduit flexible standard 2 2 nous recommandons une longueur maximale 78 et pas plus de 4 coudes voir tableau qui suit Si vous d passez ces prescriptions il faudra compenser par un diametre plus important et ou un tube plus lisse Veiller ne pas craser le conduit Longueur du Nombre max de coudes conduit 90 autoris s 4 4 coudes 8 4 coudes 10 2 coudes 12 0 coudes Le clapet de fermeture photo 4 emp che le refroidissement de la maison quand le foyer n est pas en fonctionnement Ce dispositif est donc facultatif si vous optez pour un raccordement direct sur le foyer sch mas 1 et 2 Cependant il reste int ressant si les longueurs de gaines sont trop importantes jusqu au foyer ou si l installation s effectue dans une maison haute efficacit nerg tique ll sera plac id alement le plus pres possible du mur ext rieur Attention longueur du cable de com
21. tapng screws 10 1 2 A CHIMNEY SERVING AS AN OUTLET FOR A FIREPLACE CANNOT BE USED FOR ANY OTHER APPLIANCE CAUTION PLEASE REFER TO THE INSTRUCTION MANUAL OF THE CHIMNEY MANUFACTURER FOR THE INSTALLATION DETAILS CAUTION If this appliance is not correctly installed a fire might result To reduce fire hazards follow the installation instructions Consult local authorities to obtain a construction permit and to know all applicable regulatory requirements Double wall connector a o Raccordement a la cheminee Attention N employez pas de moyens de fortune pendant l installation ils pourraient devenir dangereux et entrainer un incendie Ne reliez pas cet appareil une chemin e qui dessert un autre appareil de chauffage Ne coupez ni chevrons ni solives de plafond sans consulter au pr alable un agent du service du b timent pour viter de compromettre l Int gralit Structurale Utiliser un connecteur doubles parois noir d gagement de 6 pouces Utiliser uniquement un conduit isol de 6 ou de 7 pouces r pertori selon la norme UL 103 HT ou ULC S 629 d s que vous traversez une paroi combustible selon les normes d installations en vigueur dans votre localit Ce connecteur sera fix la buse de l appareil utilisant 3 vis auto forantes 10 1 2 UNE CHEMIN E SERVANT D VACUATION UN FOYER NE DOIT PAS SERVIR POUR AUCUN AUTRE APPAREIL ATTENTION VEUILLEZ VOUS R F RER AU MANUEL D INSTRUCTION DU
22. top screw pic 4 b and pivots on the screw c Adjust the screw pic 5 on the right hand side of the flap holding the magnet so that the magnet has sufficient force of attraction and that the flap is vertical in a closed position The magnet attracts the filings keep the contact parts clean Refitting the door Refit the door on its hinges A spring inside the door shuts it automatically picture 1 hook up the spring to its lug inside the freestanding fireplace picture 2 St v 16 cube installation en 07 2014 1 7 SN 97851 Graduated tablet Tilt the flap picture 1 Slide in the graduated tablet adjusted to the centre of the register under the register hood picture 2 It is simply placed on the 2 lateral screws Put the back edge of the tablet under the valve cover photo diagram 3 a The front edge of the tablet is inserted between the front part of the flap 3 b and the 2 lateral screws 3 c Close the flap picture 4 When the installation of the freestanding fireplace is complete Carry out a test to ensure it is See directions for use working correctly l 5 y Once installation is complete return Before this test ensure no items the directions for use to the user Fill involved in installation have been left in the guarantee certificate with him in the combustion chamber or in the at the back of the directions for use bends spr
23. ts have a thickness of 8mm Never burn the fire when the glass is broken Clean the glass when cold Avoid in any case cleaning with abrasive products Door slamming may break the glass St v 16 Maintenance St v sa info stuv com www stuv com St v reserves the right to make changes without prior notice This documentation has been compiled with the utmost care However we can not be held responsible for any inaccuracies or omissions E R V U R P VH G Pitance rue Jules Borbouse 4 5170 Bois de Villers Belgium ACCEPTANCE OF WORKS PLEASE COMPLETE IN BLOCK CAPITALS THE PURCHASER URNA NIE ere ae ee ee d IB ILU F ADDRESS WHERE WORKS WERE CARRIED OUT PO TOODE qe nan TOVN PAGES COUNTER zo ana anno INSTALLATION ENGINEER CAMPANI T EE dO Po Zk mn YOUR STUV FREESTANDING FIREPLACE 16 CUBE OR STUV 16 H IN o a A no DATE OF INSTALLATION mem meme enne FLUE CHARACTERISTICS BEIGE OF FLUE INM ataki EE koo EE A DIAMETER OF FLUE IN MM usitata deor REAR ARGE OE 542 206 2 89 c CHECK OF SYSTEM S SETTINGS CHECK ON THE VACUITY OF THE FLUE eene VALIDATION OF DRAUGHT 3e vta Feu ran rend rt dta ek rated VERIFICATION OF AIR INLET SETTING OPENCEL CED pr c CHECK OF THE HUMIDITY OF THE WOOD HUMIDITY LINO WOOD SAFETY GUIDELINES The
24. urn may Occure The gaskets must always remain in good condition This fireplace is to be used with the door closed only If not it may draw gas and flame out of the fireplace opening creating both heat and smoke hazards If necessary replace the glass only with ceramic glass Capacit portante de la structure S assurer que la r sistance du plancher soit suffisante pour supporter le foyer en cas de doute consulter un sp cialiste Environnement du fover Rayonnement Le rayonnement de la vitre et des parois peut tre important Quelque soit l orientation du foyer respectez les distances de s curit par rapport aux mat riaux combustibles sch ma 1 ou assurez vous que les mat riaux expos s ce rayonnement soient r sistants de hautes temp ratures viter les pi ges chaleur dans l habillage la niche ou la hotte Si le po le d ambiance se situe dans un environnement en forme de cloche ex ancien tre cet espace doit tre ventil pour viter les pi ges chaleur Ouverture de la porte Un gant est fourni avec le foyer et doit tre utilis pour manier la poign e d ouverture de la porte main froide Retirer et d poser la main froide proximit du foyer quand vous ne l utilisez pas Ne jamais laisser la main froide positionn e sur le foyer au risque de vous bruler Les joints d tanch it doivent toujours tre maintenu en bonne condition Le foyer doit tre utilis e
25. ve between the 2 screws photo 6 and then fasten it all Ensure the plate is level and attach it to the base photo 7 Combustion air is drawn from the room where the freestanding fireplace is installed Make sure there will be adequate air renewal once the freestanding fireplace is operating Remove all of the covers of the support plate photo 8 St v 16 cube installation en 07 2014 SN 97851 Place the freestanding fireplace onto the plate The freestanding fireplace s lug photo 1 a must be lowered onto the hole b cut in the plate Fasten the freestanding fireplace to the plate using screws and nuts photos 2 3 and 4 Put on the cover photo 5 The hole cut in the cover should be centred in relation to the freestanding fireplace s smoke outlet Attach the cover using the 4 screws at the front photo 6 starting with the lower screws The upper part of the cover has to be fixed to the freestanding fireplace using a bolt provided for this purpose photos 7 and 8 Undo the bolt s hexagonal screw photo 7 Swivel it 3 4 of a turn photo 8 and retighten D PS ESS pu EL n xp PA PE firan I APA Positioning of the freestanding Tireplace St v 16 cube installation en 07 2014 SN 97 851 Installation of the panel The panel is the part which protects the mechanisms in the lower part of the freestanding fireplace photo 3 The flap fits onto the s
26. votre municipalit ou votre compagnie d assurance concernant les exigences locales relatives aux permis et l installation de votre po le L appareil doit tre install en conformit avec le code CAN CSA B365 Gardez ce manuel pour pouvoir le consulter ult rieurement ATTENTION e NE PAS UTILISER DES PRODUITS CHIMIQUES OU AUTRES LIQUIDES POUR ALLUMER LE FEU e NE JAMAIS LAISSER LE POELE D AMBIANCESANS SURVEILLANCE LORSQUE LA PORTE EST OUVERTE e TOUJOURS FERMER LA PORTE APR S LA P RIODE D ALLUMAGE NE PAS BR LER DE D CHETS ET OU DE LIQUIDES INFLAMMABLES COMME L ESSENCE LA NAPHTA ET L HUILE DE MOTEUR e NE PAS CONNECTER LE POELE D AMBIANCEA UN SYSTEME DE DISTRIBUTION D AIR CHAUD e L APPAREIL EST CHAUD LORSQU EN FONCTION GARDEZ LES ENFANTS V TEMENTS ET MEUBLES HORS DE PORT E TOUCHER L APPAREIL POURRAIT CAUSER DES BR LURES Note Nous recommandons fortement que nos produits soient install s et entretenus par des professionnels certifi s par l Association des Professionnels du Chauffage au Qu bec ou par Wood Energy Technical Training pour le reste du Canada et par la National Fireplace Institute aux Etats Unis NATIONAL FIREPLACE INSTITUTE CO Technical specifications Caract ristiques techniques Fuel type Cordwood St v 16 cube amp H Maximum power 16 58 40 000 BTU 16 68 43 000 BTU 16 78 46 000 BTU Efficiency 80 European data Chimney type Insulated chim
27. xclusivement avec la porte ferm e Sinon des fum es et des flammes pourraient sortir de l ouverture foy re et provoquer des d g ts importants Si la vitre doit tre remplac e utilisez uniquement du verre de c ramique Tools required Outils a prevoir Af UO ESI Ud UOREJ EJSUI 1 6 cube amp H INSTALLATION On taking delivery of the equipment Please note Upon receipt of this freestanding fireplace please ensure than the glass door has not been damaged during delivery The guarantee only covers damage due to transport if it is reported within 48 hours of delivery and it is indicated on the delivery slip picture 1 Complaints Always indicate the serial number visible on the freestanding fireplace when making a complaint picture 2 Unpacking Please note The paint is not oven baked and is therefore relatively fragile but will harden after being heated a few times Handle the system with care when installing Checking the order Where accessories have been ordered frame support they will be found around the hearth or its packaging Please check all accessories are supplied as ordered Inside the combustion chamber you will find a Paint spray for touch up b grips to handle the finishing cover c flap d graduated tablet e cold handgrip to handle the door and the valve f anti sweep stainless steel bar g 2 bolts for attaching the front of the fre