Home
OPERATING AND MAINTENANCE INSTRUCTION MANUAL
Contents
1. In the case of power failure the power unit will return to its previous state when power returns For example if a hose is plugged in with the hose switch on or a straight air hose is plugged into a wall valve then the power unit will turn back on If the power unit was turned on at the unit prior to power loss then the unit will not turn back on Hose Use And Care For optimum benefit the hose should be used and stored at temperatures above 40 F 5 Always hang up the hose when not in use using the hose hanger supplied If hose should become clogged insert the wand end into the utility inlet on the power unit Turn on the power unit with the manual switch and seal the extra air space by holding the hose firmly The obstruction should be quickly vacuumed out If however the hose remains clogged insert an electrician s fish tape wire or garden hose through the hose to remove the obstruction being careful not to puncture the hose Disconnect hose handle from wands before storing DO NOT store hose in direct sunlight BEAM CENTRAL VACUUM SYSTEMS OPTIONAL EXHAUST UNE AND HEADER LOW VOLT MAIN TUEING M OPTIONAL MUFFLER HEADER LOW CONNECTORS ELECTRIC POWER UTILITY INLET M MINIMUM DISTANCE OF 12 FOR MOTOR COOLING ne 28 APPROX 31 em a 20 Figure 1 Power Unit Installation WARNING Imp
2. Beam built in vacuum power unit body and filter shall be free from defects in material and workmanship from the date of purchase until the original consumer purchaser ceases to own the system or until the system is removed from its original installation whichever occurs first Motors and electrical components in Beam units series PU s are warranted for 5 years Hoses powerbrushes and tools carry a 3 year warranty Labor on all warranted items is covered for 1 year This warranty does not apply to items requiring normal replacement such as belts bags etc THIS IS THE SOLE AND EXCLUSIVE WARRANTY OF BEAM INDUSTRIES IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD Should any defect in material or workmanship appear within the time of the above warranty the selling BEAM Dealer should be contacted The Dealer shall repair or replace at BEAM S sole option or credit such part or parts in accordance with the applicable warranty period stated above BEAM shall not be responsible for such service unless provided by an authorized BEAM Dealer utilizing authentic BEAM replacement parts This warranty does not apply to loss or damage resulting from at sole option normal wear and tear commercial use neglect abuse acts of God accidents improper installation improper modification or alteration improper use and operation
3. afin de rejeter l ext rieur les manations et les germes tout en offrant une r duction optimale du bruit Vous pouvez utiliser le m me type de tuyauterie et de raccords La sortie du syst me d chappement ne doit pas donner l int rieur d un d un plafond ou d un espace dissimul d un b timent Pour les unit s deux moteurs utilisez deux lignes d chappement NOTE Interrupteur marche arr t plac sur l unit motrice sert uniquement faire fonctionner la prise utilitaire plac e sur l unit motrice Toutes les autres prises d admission d air fonctionnent automatiquement lorsque le boyau est ins r dans soupape d admission Le cordon d alimentation une fiche femelle tripolaire a l une des extr mit s Ce connecteur doit tre branch dans le connecteur homologue de l unit motrice Branchez l autre extr mit du cordon d alimentation dans la prise lectrique murale FILAGE V rifiez les codes locaux mais n utilisez pas de filage moindre que 12 2 Branchez le cordon d alimentation de l unit motrice dans la prise de courant appropri e Assurez vous que le circuit lectrique peut supporter une charge de 20 amp res Ligne et collecteur d chappement Fils basse option Prises nord tension am ricaines Silencieux optionne Ligne de tuyauterie D Le ma tresse Bornes basse Bo te lectrique tension fournies 6 de 120 v
4. carrying capacity Introduction Congratulations You are now the proud owner of a Beam Built in Vacuum System the ultimate in cleaning equipment Say good bye to old fashioned sweepers You ll never have to lug a heavy awkward vacuum again Your Beam Built in Vacuum will change your cleaning routine It is so easy and versatile to use It s quiet and dust free It will help eliminate the drudgery of vacuuming and give you a cleaner healthier indoor environment Before you use your Beam Built in Vacuum System read this manual carefully Learning the proper way to use this system will help give you years of trouble free cleaning performance Operation To operate simply plug the hose into one of the handy wall inlet valves The metal ring on the cutoff of the hose will complete a low voltage electrical circuit which in turn activates a relay and turns on the system s power unit To turn off the power unit simply unplug the hose from the inlet Please Note When unplugging the hose it is recommended to hold the inlet door open for a few seconds until the suction pressure has sufficiently decreased For safety purposes a low voltage circuit is utilized at the wall inlet The power unit functions on a standard 110 120 volt circuit There are optional hoses available with an on off switch located on the handle Please note When using one of these optional hoses it is important to properly align the hose with
5. crit dans ce guide Lutilisation d accessoires non recommand s par le manufacturier peut tre la cause d incendie de d charges lectriques de blessures ou encore de dommages aux composantes du syst me N utilisez jamais cet aspirateur si la fiche ou le fil lectrique sont endommag s s il ne fonctionne pas ad quatement s il a t chapp ou endommag Retournez le votre d taillant autoris Beam pour r paration Ne tirez pas ou transportez pas l unit motrice en utilisant le cordon d alimentation N utilisez pas le cordon d alimentation comme poign e Ne d branchez jamais la fiche en tirant sur le fil Pour d brancher de la prise de courant prenez et tirez la fiche et non le fil N ins rez aucun objet dans les prises d aspiration Ne vous servez pas de cet appareil si une des prises est obstru e Assurez vous qu aucune accumulation de poussi re charpie cheveux ou autres ne peut r duire le flux d air Tenez loign s des prises d aspiration les cheveux la figure les doigts ou toutes autres parties du corps ainsi que les v tements amples N aspirez pas de cigarettes de cendres chaudes d allumettes ou autres objets similaires N utilisez jamais votre appareil sans que le sac poussi re et ou le filtre ne soient place Fermez toutes les commandes avant de d brancher Ne manipulez jamais la fiche le fil lectrique ou l unit motrice avec des mains humides N utilisez jamais
6. e l unit motrice ne fonctionnera pas et la DEL sera teinte Si jamais ces probl mes surviennent pressez l interrupteur marche arr t d branchez le boyau ou attendez que la temp rature baisse Si les probl mes persistent contactez le centre de service autoris le plus pr s En cas de panne de courant l unit motrice reviendra son tat pr c dent lorsque le courant reviendra Par exemple si un boyau est branch dans la prise murale l unit motrice red marrera Si l unit motrice tait allum e l unit motrice avant la panne de courrant l unit ne red marrera Utilisation et entretien du boyau Pour obtenir un rendement optimal de votre boyau celui ci doit tre utilis et rang des temp ratures sup rieures 40 F 5 C Lorsqu il n est pas utilis le boyau doit toujours tre suspendu sur le support boyau fourni cet effet Si le boyau est obstru ins rez le bout de celui ci dans la prise utilitaire plac e sur l unit motrice Mettez l unit motrice en marche a l aide de l interrupteur manuel et scellez l espace d air en tenant fermement le boyau Ce qui obstrue le boyaudevrait tre aspir rapidement Si ce n est pas le cas et que le boyau demeure obstru ins rez un c ble de traction d lectricien ou un boyau d arrosage dans le boyau de l aspirateur pour le d bloquer en prenant bien soin de ne pas le percer Retirez les tubes de la poign e du boyau avant de ranger rang
7. liquides car il y a risque de d charges lectriques e Ne manipulez pas l unit motrice Ne placez aucun objet sur le dessus de celle ci ceci pourrait restreindre le refroidissement de l air du moteur et de ce fait causer une surchauffe du moteur e Nessayez jamais d aspirer quelque chose qui ne passera pas dans l ouverture de l accessoire ou l extr mit du boyau N utilisez pas votre syst me d aspiration pour ramasser des d bris de construction e Ne branchez rien d autre la prise de courant du syst me Assurez vous qu un circuit prot g ad quat est utilis pour r pondre aux besoins lectriques de votre unit Votre d taillant autoris Beam est en mesure de vous indiquer les normes recommand es e Apr s avoir retir le boyau de la prise d aspiration maintenez la soupape ouverte pendant quelques secondes pour aider a d gager la salet des tuyaux et assurez vous que l unit motrice est bien arr t e e Pour un nettoyage ad quat n utilisez qu une prise d aspiration a la fois e S il advenait que votre syst me ait besoin d entretien ou de r paration assurez vous que le service sera effectu par votre d taillant autoris de syst mes centraux d aspiration Beam Entretien du filtre Le filtre exclusif de Beam est permanent et autonettoyant Cependant si vous d sirez le nettoyer vous pouvez le faire en suivant les cinq tapes faciles suivantes 1 Retirez la cuve poussi
8. marrer celle ci d branchez l unit motrice de la prise de courant murale pendant 2 minutes pour lui permettre de refroidir et de se r initialiser Apr s 2 minutes rebranchez l unit motrice et mettez la en MARCHE Si l unit motrice D MARRE pas r p tez ces directives une autre fois en prolongeant le temps de refroidissement Si l unit motrice ne fonctionne toujours pas communiquez avec votre d taillant ou distributeur autoris local Garantie Limit e Beam Industries garantie au consommateur acheteur initial que le bo tier et le filtre de l unit motrice du syst me central d aspiration seront exempts de tous d fauts de mat riaux ou de fabrication Cette garantie est en vigueur compter de la date d achat tant que l acheteur initial sera propri taire du syst me ou jusqu ce que le syst me soit retir de son emplacement d installation initial selon la premi re des deux situations se produire Les moteurs et les composantes lectriques des unit s motrices de la s rie PU sont couverts par une garantie de 5 Les boyaux les brosses motoris es et les accessoires sont couverts par une garantie de 3 ans Les frais de main d oeuvre sur tous les articles sous garantie sont couverts pendant 1 an Cette garantie ne s applique pas aux articles demandant un remplacement normal comme les courroies les sacs etc CETTE GARANTIE EST LA SEULE ET UNIQUE GARANTIE OFFERTE PAR BEAM INDUS
9. or failure to provide proper maintenance Some States or Provinces do not allow exclusion of warranties or limitations of damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights You may have additional rights which vary from State to State or Province to Province This limited warranty applies to USA and Canada installations only For specific warranty information for your Country consult your authorized Beam Dealer Other warranties apply to other parts of this equipment and optional accessories Please consult the materials accompanying the individual items BEAM SHALL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES ARISING FROM THE USE OF THIS SYSTEM Keep all payment records bill of sale delivery slip The date on these records establishes the warranty period Should warranty service be required you must show proof of purchase If proof of purchase cannot CENTRAL VACUUM SYSTEMS be supplied the warranty period will be determined from the date of manufacture of the product Canada Electrolux Home Care Products Canada Inc 5855 Terry Fox Way Mississauga Ontario L5V 3E4 To place on file proof of the required information fill out and return the Warranty Card which is included in with your power unit or register online at wwnv beamvac com Note Be sure to specify Model and Serial numbers when writing for information or r
10. pas constante d une prise l autre cela signifie qu il y a obstruction partielle dans les conduits Pour localiser la partie obstru e dans le syst me recommencez v rifier la succion a chaque prise en d butant par celle la plus proche de l unit motrice Continuez la v rification de chaque prise jusqu ce que vous ayez trouv la prise o la perte de succion se fait sentir Lobstruction devrait donc tre situ e entre cette prise et celle v rifi e juste avant Pour d bloquer ins rez d licatement une fiche m tallique d lectricien dans la prise d aspiration et pousser sur ce qui cause l obstruction Une autre m thode consiste utiliser un autre aspirateur pour inverser la succion dans le syst me et ainsi liminer la cause de l obstruction Si aucune de ces m thodes ne r ussit communiquez avec votre d taillant Beam 3 Demandez votre d taillant autoris Beam de v rifier le joint d isolation plac au dessous du moteur ainsi que le joint d tanch it au point d attache de la cuve poussi re et du bo tier de l unit scell e Perte totale de succion alors que le moteur tourne 1 Assurez vous que le boyau n est pas obstru 2 Mettez l unit motrice en marche avec interrupteur marche arr t et suivez la proc dure d crite au paragraphe 2 pr c dent Toutefois lors d une perte totale de succion toutes les prises d aspiration s il s agit d un probl me d obstruction dans les condui
11. the wall inlet when plugging it in to prevent damage to the unit Power Unit Beam power units are equipped with 115 120 volt by pass motors Beam power units also employ a manual reset circuit breaker It is normal for some dirt and lint to cling to the filter However the filter should be checked occasionally to be sure it has not been punctured or torn The dirt receptacle should be emptied two or three times a year on the average depending on the amount of use For best results empty the canister when it is about half full Any dirt spilled can be vacuumed up quickly by plugging the hose into the utility inlet located on the power unit The on off button on the power unit will start and stop the power unit No part of the unit requires lubrication Electrical Fault Protection The central vacuum system employs features that monitor the following operating levels AC voltage current draw and circuit board temperature If the voltage is below or above the standard operating voltage high current draw or locked rotor the power unit will not operate In this case the LED next to the on off button will blink until the problem ceases If the circuit board reaches an elevated temperature the power unit will not operate and the LED will be off In the event of these problems happening press the on off button unplug hose or wait for temperature to lower If problems persist contact the authorized service center nearest you
12. Beam Central Vacuum Systems OPERATING AND MAINTENANCE INSTRUCTION MANUAL WARRANTY INFORMATION Read This Manual Thoroughly Before Use BEAM CENTRAL VACUUM SYSTEMS Beam Central Vacuum Systems Operating and maintenance instruction manual WARRANTY INFORMATION Read this manual thoroughly before use IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances basic safety precautions should always be followed including the following Read all instructions before using this vacuum NOTE Your Beam Built In Vacuum is listed and approved by the appropriate agencies for dry pick up only Please see your rating plate for details To reduce the risk of electrical shock DO NOT USE on wet surfaces SAVE THESE INSTRUCTIONS DANGER Always unplug power unit from the electrical outlet before servicing and cleaning WARNING To reduce the risk of burns fire electric shock or injury to persons Keep cord away from heated surfaces Do not allow vacuum to be used as a toy Close supervision is necessary when this vacuum is used by or near children Use this vacuum only for its intended use as described in this manual Use of attachments not recommended by manufacturer may cause fire electric shock injury or damage to system components Never operate this vacuum if it has a damaged cord or plug if it is not working properly or if it has
13. TRIES TOUTES GARANTIES IMPLICITES INCLUANT LES GARANTIES IMPLICITES RELATIVES LA QUALIT MARCHANDE OU UNE UTILISATION DES FINS PARTICULI RES AUTRE QUE CELLE POUR LAQUELLE LE PRODUIT A T CON U SONT LIMIT ES EN TEMPS LA P RIODE DE GARANTIE LIMIT E Dans le cas o un d faut de mat riel ou de fabrication appara trait durant la p riode couverte par la pr sente garantie vous devez communiquer avec le d taillant BEAM qui vous a vendu l appareil Le d taillant r parera ou remplacera au seul choix de la ou les pi ces jug e s d fectueuse s conform ment la p riode de couverture applicable stipul e plus haut ne pourra tre tenue responsable de tels services moins qu ils n aient t offerts par un d taillant autoris BEAM utilisant des pi ces de rechange authentiques Cette garantie ne s applique pas aux pertes ou dommages r sultant d une usure normale d un usage commercial d une n gligence d un abus de catastrophes naturelles d accidents d une installation inad quate d une modification inad quate ou d une alt ration d un usage ou d une utilisation inappropri s ou d un manque d entretien ad quat Certains tats ou provinces ne permettent pas les exclusions de garanties ou les limitations de dommages il se peut donc que les limitations ou exclusions mentionn es ci dessus ne s appliquent pas vous Cette garantie vous conf re des droits l g
14. anels in your house 2 If your power unit has a control light the green light will indicate when the unit has proper voltage and the low voltage circuit is supplying power to the inlets Should the light be on but the motor starts only with the on off button and not at the inlets the problem is broken low voltage wiring to the wall inlets Call your authorized Beam dealer Automatic Shutoff In the unlikely event the unit is unintentionally left ON your central vacuum has two different safe guards to automatically turn OFF the unit to protect your vacuum from motor damage The first safe guard is a 30 minute timer which will automatically turn OFF the power unit after 30 minutes of continual use To restart remove the hose from the wall inlet and reinsert the power unit should come back ON The second safe guard is thermal protection shutoff to prevent any accidental overheating of the vacuum motor and will automatically turn OFF the unit To restart unplug the power unit from the wall for 2 minutes allowing the power unit to cool down and reset itself After the 2 minute period plug the power unit back into the wall and turn the power unit ON If the power unit does not turn ON repeat the procedure one more time for extra cooling time If the power is still not operational please contact your authorized dealer or distributor Lifetime Limited Warranty Beam Industries warrants to the original consumer purchaser that the
15. aux sp cifiques mais vous pourriez avoir d autres droits qui varient d un tat ou d une province l autre Cette garantie limit e s applique uniquement aux installations faites aux tats Unis ou au Canada Pour obtenir les d tails sp cifiques de la garantie offerte dans votre pays veuillez consulter votre d taillant autoris Beam Les autres pi ces de cet quipement et les accessoires optionnels sont couverts par des garanties distinctes Veuillez vous r f rer la documentation incluse avec ces articles pour en conna tre la teneur M BEAM NE POURRA TRE TENUE RESPONSABLE DE TOUS DOMMAGES A CONS CUTIFS INDIRECTS OU SP CIAUX CAUS S PAR L UTILISATION DE CENTRAS VA CETE STENS CE SYSTEME E U 2 Electrolux Central Vacuum Systems Conservez toutes les preuves d achat coupon de caisse bon de livraison La 1700 W Second date apparaissant sur ces documents sert tablir la p riode de garantie Si une Webster City lowa U S A 50595 demande de service sous garantie doit tre faite vous devrez pr senter ces preuves d achat Si une preuve d achat ne peut tre produite la p riode de garantie Canada sera d termin e partir de la date de fabrication du produit Electrolux Home Care Products Canada Inc 5855 Terry Fox Way Pour nous permettre de garder en fili re une preuve de l information requise veuillez Mississauga Ontario L5V 3E4 remplir et retourner la carte de garanti
16. been dropped or damaged Return to your authorized Beam dealer for repair Do not pull or carry this power unit by supply cord or use cord as a handle Never disconnect plug by pulling cord To disconnect from outlet grasp the plug not the cord Do not put any object into openings Do not use with any opening blocked Keep free of dust lint hair and anything that may reduce air flow Keep hair face fingers and all body parts and loose clothing away from any openings Do not pick up cigarettes live hot ashes matches or similar materials Never operate vacuum without dust bag and or filter in place Turn off all controls before unplugging Never handle plug cord or power unit with wet hands Do not use on wet surfaces Use extra care when cleaning on stairs Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present Connect to a properly grounded earthed outlet only See grounding earthing instructions Do not block the motor hood ventilation openings on top of the power unit lack of ventilation airflow will cause the motor to overheat Do not locate the power unit in a high temperature area or where it is inaccessible for example an attic or crawl space Mount the built in vacuum system power unit at least 12 inches from the floor ceiling and adjacent sidewall to insure adequate ventilation for the motor Do not use extension cords or outlets with inadequate current
17. cet appareil des surfaces mouill es Soyez tr s prudent lorsque vous nettoyez les escaliers N utilisez jamais ce syst me pour aspirer des liquides inflammables ou com bustibles tels que l essence ou dans un endroit o des produits de ce genre pourraient tre pr sents Branchez ce syst me uniquement sur une prise de courant mise la terre Consultez nos instructions concernant les prises de mise Ne bloquez pas les fentes de ventilation du capot du moteur qui se trouvent sur le dessus de l unit motrice Un manque du d bit d air de ventilation causera une surchauffe du moteur Ne placez pas l unit motrice dans un endroit temp rature lev ou dans un endroit difficile d acc s comme un grenier o un vide sanitaire Installez l unit motrice du syst me central d aspiration au moins 12 pouces du sol du plafond et des murs adjacents afin d assurer une ventilation ad quate du moteur N utilisez pas de rallonges ou de prises de courant qui ont une intensit de courant admissible inad quate Introduction F licitations Vous tes maintenant l heureux propri taire d un syst me central d aspiration Beam le summum en quipement de nettoyage Dites bonjour aux balais d mod s Vous n aurez plus jamais besoin de pousser ou tirer un aspirateur portatif lourd et encombrant Votre aspirateur central Beam changera votre routine de travaux m nagers II est tellement pratique et facile utiliser Il
18. e pas endommager la prise Unit motrice Les unit s motrices Beam sont dot es d un moteur d rivation de 110 120 volts Il est normal que de la poussi re et de la charpie collent au filtre Ce dernier doit galement tre v rifi occasionnellement pour s assurer qu il n est pas perc ou d chir La cuve poussi re doit tre vid e en moyenne deux ou trois l an d pendant de l utilisation faite du syst me Pour de meilleurs r sultats videz la d s qu elle est moiti pleine Toute poussi re qui s en serait chapp e peut tre rapidement aspir e en branchant le boyau dans la prise utilitaire plac e sur l unit motrice Interrupteur marche arr t sur l unit motrice sert la mettre en marche et Aucune pi ce de l unit motrice ne requiert de lubrification Protection contre les d fauts d origine lectrique Le syst me central d aspiration fait appel des caract ristiques qui surveillent les niveaux de fonctionnement suivants tension alternative appel de courant et temp rature de la plaquette circuits imprim s Si la tension est sup rieure ou inf rieure la tension de service nominal l appel de courant lev ou au courant rotor bloqu l unit motrice ne fonctionnera pas Dans ce cas la DEL plac e pr s de l interrupteur marche arr t clignotera jusqu ce que le probleme cesse Si la plaquette circuits imprim s atteint une temp rature lev
19. e qui est incluse avec votre unit motrice ou enregistrer votre garantie en ligne www beamvac com Note Assurez vous de bien sp cifier les num ros de mod le et de s rie lorsque vous nous crivez pour obtenir de l information ou des pi ces de remplacement No 460426 R1 Lit CVS Manual w Wrnty Card
20. eplacement parts BEAM CENTRAL VACUUM SYSTEMS Systemes centraux d aspiration Beam Guide d emploi et d entretien RENSEIGNEMENTS SUR LA GARANTIE Lisez attentivement ce guide avant d utiliser votre sys t me DIRECTIVES IMPORTANTES DE SECURITE Lors de l utilisation d appareils lectriques des pr cautions de base devraient toujours tre prises afin d assurer votre s curit Celle ci en fait partie Lisez toutes les directives comprises dans ce guide avant d utiliser votre aspirateur NOTE Votre aspirateur central Beam est catalogu et approuv par les organismes appropri s pour un usage sec seulement Pour plus de d tails consultez la plaque signal tique de votre appareil Afin de minimiser les risques de d charges lectriques NE LUTILISEZ JAMAIS sur des surfaces mouill es Guide d emploi et d entretien CONSERVEZ CES INSTRUCTIONS D branchez toujours l unit motrice avant d en faire l entretien ou la r paration AVERTISSEMENT Pour r duire les risques d incendie d charges lectriques br lures ou blessures lisez bien ce qui suit Tenez le fil loin de toutes surfaces chauff es Ne permettez jamais aux enfants de jouer avec l aspirateur Une surveillance troite est n cessaire lorsque cet aspirateur est utilis par des enfants ou pr s d eux N utilisez cet aspirateur que pour l usage pour lequel il a t con u tel que d
21. est silencieux et ne fait pas de poussi re La corv e de passer l aspirateur sera moins p nible et vous aurez un environnement int rieur plus propre et plus sain Avant de commencer utiliser votre syst me central d aspiration Beam lisez attentivement manuel En apprenant vous servir ad quatement de ce syst me vous vous assurez de b n ficier de son bon fonctionnement sans probl mes et pour de nombreuses ann es Fonctionnement Pour l utiliser vous n avez qu brancher le boyau dans une des prises murales d aspiration m tallique fix l extr mit du boyau produira un courant lectrique bas voltage qui en retour activera un relais et mettra en marche l unit motrice du syst me Pour arr ter l unit motrice vous n avez qu retirer le boyau de la prise murale d aspiration NOTE lorsque vous d branchez le boyau il est recommand de garder la soupape de la prise d aspiration ouverte pendant quelques secondes jusqu ce que la pression de succion suffisamment baiss e Par mesure de s curit la prise murale est dot e d un circuit L unit motrice fonctionne soit sur un circuit standard de 110 120 volts Vous pouvez galement vous procurer des boyaux dot s d une poign e avec interrupteur marche arr t NOTE si vous utilisez l un de ces boyaux offerts en option il est important de bien aligner le boyau la prise murale lorsque vous le branchez afin de n
22. ez PAS le boyau dans un endroit o il serait expos la lumi re directe du soleil BEAM CENTRAL VACUUM SYSTEMS Guide d emploi et d entretien Installation de l unit motrice L unit motrice doit tre suspendue un support de fixation viss au mur Les vis allant au bas du support de fixation doivent tre viss es environ 122 cm 48 au dessus du plancher afin de pouvoir enlever la cuve poussi re Un espace d au moins 31 cm 12 doit galement tre laiss entre le plafond et l unit motrice afin de permettre un refroidissement ad quat du moteur Illustration 1 Si le support de fixation est install sur du pl tre ou des panneaux muraux assurez vous que les vis soient ins r es dans les poteaux du mur Si l installation du support se fait sur un mur de b ton percez le mur avec un foret ma onnerie et ins rez les boulons d ancrage appropri s Une fois l unit motrice install e sur le support d nudez le fil basse tension et pincez le dans les deux bornes d enfilage fournies Raccordez la ligne de tuyauterie principale l unit motrice du c t gauche de celle ci l aide du raccord et du collier de serrage fourni Ne collez pas ce raccord l unit motrice au cas o vous voudriez enlever celle ci plus tard NOTE Pour les unit s motrices munies de sacs en papier suivez les directives fournies avec l unit Un syst me d chappement peut tre install sur ces unit s
23. he low voltage wires that were installed with the main trunk line Connect the wires to the spring loaded connectors on the back side of the power unit Connect the main tube line to the left side of the power unit with the connector and clamp provided Do not cement this connection to the power unit in case you wish to remove at some future date NOTE For paper bag units follow directions provided with unit This unit may be vented outside to exhaust fumes and germs For optimum noise reduction this unit must be vented outside Use the same tubing and fittings as before Do not vent power unit exhaust into a wall ceiling or concealed space of a building Use two exhaust lines for twin motor units NOTE On off button on power unit is only used for the inlet on power unit All other inlets operate automatically when hose end is inserted into inlet valve The power cable has a three prong female connector on one end This connector must be plugged into the mating connector on the power unit Plug the other end of the power cable into the wall electrical outlet WIRING Check local codes but use not less than 12 2 wire with ground Plug power unit cord into appropriate electrical outlet Be sure line voltage is sufficient to handle 20 amp load North American Outlets Ca 29 Grounding NEMA5 15P Earthing Figure 2 Instructions This appliance must be grounded earthed If it should malfunction or break down groundi
24. nal de 120 ou 240 volts consultez la plaque signal tique pour savoir quel est le circuit appropri et est dot d une fiche avec mise la terre qui ressemble l une de celles montr es l illustration 2 Assurez vous que l appareil est branch dans une prise de courant ayant la m me configuration que la fiche Aucun adaptateur ne doit tre utilis avec cet appareil Si le c ble de l unit motrice est endommag utilisez seulement un c ble de rechange d origine Assurez vous que l interrupteur bascule de l unit motrice et que toutes les soupapes d admission fonctionnent parfaitement bien Ce syst me central d aspiration a t con u pour un usage domestique ou commercial Entretien Votre syst me central d aspiration Beam est couvert par une garantie vie limit e les d tails complets de la garantie apparaissent plus loin dans cette brochure En suivant les quelques simples recommandations qui suivent vous pourrez profiter des avantages de votre syst me central d aspiration sans probl mes et pour de tr s nombreuses ann es e Le moteur jamais besoin d tre lubrifi Les roulements sont scell s et lubrifi s de fa on permanente Les brosses de moteur devraient tre v rifi es par votre d taillant autoris Beam apr s 500 heures d utilisation e L unit motrice peut tre pousset e avec un linge doux et propre Attention ne jamais utiliser d eau ou de produits d entretien
25. ng earthing provides a path of least resistance or electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding earthing plug The plug must be plugged into an appropriate outlet that is properly installed and grounded earthed in accordance with all local codes and ordinances Care and Maintenance Your Beam Built in Vacuum comes with a lifetime limited warranty see complete warranty details elsewhere in this pamphlet It will give you a lifetime of trouble free service by following some simple guidelines e Motor never needs lubrication Bearings are permanently sealed and lubricated Motor brushes should be checked by your authorized Beam dealer after 500 hours of use Power unit can be dusted off with a clean soft cloth Caution do not use liquid cleaners or water as an electrical shock may occur Do not tamper with power unit Do not place anything on top of power unit as this could restrict cooling air to the motor causing the motor to overheat Do not attempt to pick up anything that will not go through the cleaning tool or hose end Do not use the system to pick up construction debris Do not attach anything else to the system s electrical power source Be sure that a properly sized protected circuit is used for your unit s electrical requirements Consult your authorized Beam dealer for the correct size e After
26. olts gt ise la terre 7 mise Broche de mise 2 la terri ere NEMA 5 15P Illustration 2 Prise lectrique Instructions de mise la terre Cet appareil doit tre mis a la terre En cas de mauvais fonctionnement ou de bris la mise a la terre procure une voie offrant moins de r sistance pour le courant lectrique ce qui r duit les risques de d charge lectrique Cet appareil est dot d un fil et d une fiche lectriques munis d un conducteur avec mise la terre La fiche doit tre branch e dans une prise appropri e laquelle doit tre a ad quatement install e et mise la terre conform ment tous les codes et r glements locaux Prise utilitaire y distance minimum de 31 12 pour permettre i le refroidissement du moteur Envirion 70 28 Illustration 1 Installation de l unit motrice AVERTISSEMENT Un branchement inad quat de l quipement de mise la terre entra ne des risques de d charges lectriques Si vous n tes pas certain que la prise soit convenablement mise la terre consultez un lectricien qualifi ou un technicien de service autoris Ne modifiez jamais la fiche qui vous est fournie avec l appareil Si elle ne s adapte pas la prise de courant faites installer une prise de courant ad quate par un lectricien qualifi Cet appareil doit tre utilis avec un circuit nomi
27. re 2 Entourez la portion inf rieure de l unit motrice d un grand sac a d chets en plastique et tenez le solidement en place tel qu illustr 3 Passez votre main sous le sac de plastique attrapez le bas du filtre et secouez le vigoureusement La poussi re tombera dans le sac 4 Retirez d licatement le sac de plastique de l unit Puis videz la cuve poussi re dans le sac 5 Remettez la cuve a poussi re en place sur l unit motrice Rappelez vous que toute poussi re qui a pu s chapper peut tre facilement ramass e en ins rant le boyau dans la prise utilitaire et en vous servant de l interrupteur manuel pour BEAM CENTRAL VACUUM SYSTEMS Guide d emploi et d entretien Cuve Votre aspirateur est dot d agrafes qui fournissent une prise serr e la cuve Pour enlever la cuve pour vider salet ou pour v rifier le filtre soutenir la cuve et lever les agrafes Les deux c t s doivent tre lib r s pour enlever la cuve Note Si la cuve est plein ou contient des d bris lourds vous devez avoir une prise ferme sur la cuve pour emp cher le d bordement D pannage Perte partielle de succion 1 Nettoyez la cuve poussi re Examinez et nettoyez le filtre voir Entretien du filtre Remettez la cuve poussi re en place 2 Faites d marrer l unit motrice avec interrupteur marche arr t V rifiez ensuite la succion d air chaque prise d aspiration Si celle ci n est
28. removing the hose from the inlet hold the inlet door open for a few seconds to help clear dirt from the vacuum tubing and make sure the power unit has been turned off To ensure proper cleaning use only one inlet at a time If service is ever required have it performed by your authorized Beam dealer Filter Maintenance Beam s exclusive filter is permanent and self cleaning However if cleaning is desired just follow these five easy steps 1 Remove the dirt receptacle 2 Wrap a large plastic trash bag around the lower portion of the power unit holding it firmly in place as illustrated 3 Grasp the sewn in weight at the bottom of the filter through the bag as shown Shake vigorously Dirt will drop into bag 4 Carefully remove the plastic bag from the unit Then empty the dirt receptacle into the bag as well 5 Replace the dirt receptacle on the power unit Remember any dirt that is spilled can be easily vacuumed by attaching the hose to the utility inlet and activating the power unit with the manual switch BEAM CENTRAL VACUUM SYSTEMS Bucket Your Beam Built in Vacuum has two swing down clasps that provide a firm tight hold to the bucket To remove the dirt bucket to empty or check filter hold bucket lip and pull locking tab outward to release clasp Both sides must be released to remove bucket Note If bucket is full or otherwise contains heavy deb
29. ris you must have a firm hold on the bucket to prevent spillage Trouble Shooting Partial Loss Of Suction 1 Clean out dirt receptacle Inspect and clean filter see Filter Maintenance Replace dirt receptacle 2 Turn ON power unit with on off button Then check the suction at each inlet If it is not the same at each one the line is partially clogged To locate the clogged area in the system start with the inlet closest to the power unit and check the suction Continue to check each successive inlet until you locate the inlet where a loss In suction is occurring The clog will be between that inlet and the previous one you checked To remove the clog carefully Insert an electrician s fish tape in the inlet and push the obstruction through Or with another vacuum you can reverse the suction in the system to remove the clog If neither method is successful call your Beam dealer 3 Have your authorized Beam dealer check the gasket under the motor and the gasket located where the dirt receptacle attaches to the upper cylinder Total Loss Of Suction with motor running 1 Check the hose for obstruction 2 Turn on power unit with the on off button and follow the same procedure as in step 2 above However with a total loss of suction at all inlets if the problem is a clog in the system it would be located between the power unit and the first inlet Motor Refuses To Start 1 Check fuses or breakers trip switches in the electric p
30. roper connection of the equipment grounding earthing conductor can result in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded earthed Do not modify the plug provided with the appliance If it will not fit the outlet have the proper outlet installed by a qualified electrician This appliance is for use on a nominal 120 volt see rating plate for correct voltage circuit and has a ground earth plug that looks like the plug illustrated in Figure 2 Make sure that the appliance is connected to an outlet having the same configuration as the plug No adapter should be used with this appliance e If the power cable is damaged use only OEM replacement cable e Check the power unit on off button and all inlet valves for operation e This power unit is intended for household and commercial use only Installation Of Power Unit The power unit hangs on the mounting bracket which is screwed to the wall The bottom screws of the mounting bracket should be about 48 122 cm up from the floor to allow convenient removal of the dirt receptacle For proper motor cooling there must be at least 12 31 cm between unit and the ceiling see Figure 1 If mounting on plaster or panel walls be sure mounting screws enter studs If mounting on concrete wall drill the wall with a masonry bit and insert the appropriate wall anchors Strip t
31. ts du syst me celle ci devrait se trouver entre l unit motrice et la prise situ e le plus pr s de l unit Le moteur refuse de d marrer 1 V rifiez les fusibles ou les disjoncteurs des panneaux lectriques de votre maison 2 Si votre unit motrice est dot e d une lampe t moin sur le panneau de commande la lumi re verte indique quand l unit utilise la tension lectrique appropri e et quand circuit le courant aux prises Si cette lumi re est allum e mais que le moteur ne d marre qu avec l interrupteur manuel et que les prises ne fonctionnent pas il s agit d un relais d fectueux ou d un bris de fil basse tension Arr t automatique Dans l ventualit peu probable o l unit motrice serait laiss e en marche par inadvertance votre aspirateur central est quip de deux diff rents dispositifs de protection qui ARR TENT automatiquement l unit motrice pour viter que le moteur de votre aspirateur soit endommag Le premier dispositif de protection est une minuterie de 30 minutes qui ARRETERA automatiquement l unit motrice apr s 30 minutes de fonctionnement continu Pour red marrer l unit motrice retirez le boyau de la prise d aspiration murale puis r ins rez le l unit motrice devrait REDEMARRER Le second dispositif est un dispositif d arr t thermique qui sert pr venir toute surchauffe accidentelle du moteur de l aspirateur et qui ARRETERA automatiquement l unit motrice Pour red