Home
Instructions d`assemblage
Contents
1. Theassembler is urged to follow the instructions exact ly as provided The Heath Company assumes norespons ibility nor liability for any damages or injuries sustained in the assembly of the device or in the operation of the completed instrument HEATH COMPANY Benton Harbor Michigan For VTVM S with 3y Full Scale Range ASSEMBLING THE HEATHKIT no s HIGH VOLTAGE PROBE KIT PROBE BODY BODY SPRING l T 1 COLAR SCREW 1030 MEGOHM RESISTOR CCG som Cum D CNN HANDLE THE 1090 MEGOHM RESISTOR WITH CARE AS OUTLINED IN THE NOTE PACKED WITH THIS PART Remove the screw from one end and replace with the collar screw Screw the body spring onto the long part of the collar screw Slip the insulator sleeve over the body spring and slip this assembly Into the probe body with the resistor towards the tip Assemble the cable as shown by soldering the test lead to the proper lug on the phone plug Then replace the bakelite cap on the phone plug Now solder the test lead to the eyelet in the connector Screw the test lead assembly to the probe body thus compressing the body spring and insuring proper con tact between resistor and tip and between spring and test lead assembly This test probe when used with a standard 11 megobm input resistance VTVM will increase the voltage ranges by a factor of 100 Connect the probe to the VTVM in place of the regular DC test probe PARTS LIST 492 1 1 Connector 476 2 1 P
2. corps du connecteur puis immobilisez le sa place en serrant la vis de pression lat rale 1 Vissez maintenant le connecteur sur le corps de la sonde en comprimant le ressort de pression de la r sistance Pendant cette op ration veillez ce que l extr mit de la r sistance fasse bon contact avec la pointe de touche de m me que le ressort de pression avec le connecteur NB De bons contacts sont essentiels pour que la sonde THT remplisse sa fonction La sonde est maintenant assembl e Connectez la votre voltm tre lectronique la place du cordon de mesure pour courant continu Reli e un voltm tre lectronique dont l imp dance d entr e est de 11 MQ toutes les lectures seront multipli es par le facteur 100 Ainsi la gamme 100 V devient 10 000 V la gamme 150 V devient 15 000 V et la gamme 300 V devient 30 000 V Attention Quoique th oriquement la gamme 500 V puisse tre tendue pour des me sures de 50 000 V nous d conseillons vivement l utilisation au del de 30 000 Volts Cette sonde l ve l imp dance d entr e du voltm tre lectronique 1100 MQ Cette particularit permet de faire des mesures dans des circuits haute r sistance sans modifier la charge Cette r sistance additionnelle permet galement d utiliser les gammes 1 5 Volts 3 Volts ou 5 Volts La gamme 1 5 V devient 150 V la gamme 3 V devient 300 V et la gamme 5 V devient 500 V MODE D EMPLOI DE LA SONDE ATTENTION LES H
3. the insulator sleeve over the body spring and slip this assembly into the probe body with the resistor towards the ti Assemble the cable as shown by soldering the test lead to the proper lug on the phone plug Then replace the bakelite cap on the phone plug Now solder the test lead to the eyelet in the connector Screw the test lead assembly to the probe body thus compressing the body spring and insuring proper con tact between resistor and tip and between spring and test lead assembly This test probe when used with a standard 11 megohm input resistance VTVM will increase the voltage ranges by a factor of 100 Connect the probe to the VIVM in place of the regular DC test probe PARTS LIST 432 1 1 Connector 476 2 1 Probe Body 2 47 1 1090 Megohm Resistor 250 6 1 Hex Collar Serew 258 2 1 Tip Spring 258 3 1 Body Spring 341 3 1 Heavy Test Lead 70 1 1 Insulator Sleeve 438 3 1 Phone Plug o li CAUTION HIGH VOLTAGES ARE EX TREMELY DANGEROUS NEVER MEA SURE DC VOLTAGES IN EXCESS OF 30 000 VOLTS This probe is designed to permit high vol tage measurements to be made as safely as possible ALWAYS MAKE SURE THAT THE GROUND CLIP IS CONNECTED BETWEEN THE CHASSIS OF THE UNIT UNDER TEST AND THE VTVM AND THAT THE PROBE IS CONNECTED TO THE VIVM Wherever possible contact the high voltage by hooking the tip spring to the terminal un der test This should be done with the power turned off Then wit
4. 090 M2 AVEC PRECAUTION AINSI QU IL EST INSTAMMENT RECOMMANDE DANS LA NOTE JOINTE DANS L EMBALLAGE DE CETTE PIECE CONSEILS DE CONSTRUCTION Retirez la vis de l une des extr mit s de la r sistance de 1090 MEI et remplacez la par la vis collerette No 250 6 Vissez maintenant le ressort de pression sur la partie filet e de la vis collerette Glissez le manchon isolant sur le ressort de pression puis introduisez les en semble dans le corps de la sonde la r sistance tant dirig e vers la pointe de touche Retirez 6 mm d isolant chaque extr mit des deux cordons puis tamez l g re ment les brins D vissez le capuchon de la prise de Jack et glissez les deux cordons ensemble au travers du trou de passage comme indiqu Soudez le cordon rouge la cosse centrale de la prise de Jack et le cordon noir la cosse lat rale Rabattez les languettes d ancrage sur les cordons afin d emp cher qu une traction n arrache les cosses II Revissez le capuchon sur la prise 1 1 Soudez la pince crocodile l autre extr mit du cordon noir Glissez l autre extr mit du cordon rouge au travers du flexible du connecteur en commencant par la partie vas e dont l extr mit doit d boucher dans l oeil let au centre du disque isolant comme indiqu puis soudez rapidement NB Un temps de soudure exag r risquerait de br ler l isolant wearers Page 3 1 Forcez le flexible dans le
5. AUTES TENSIONS SONT EXTREMEMENT DANGEREUSES NE MESUREZ JAMAIS DES TENSIONS CONTINUES SUPERIEURES A 30 000 VOLTS Cette sonde est tudi e pour permettre de mesurer des hautes tensions avec une mar ge de s curit suffisante AVANT DE PROCEDER A UNE MESURE ASSUREZ VOUS QUE LA PINCE CROCO DILE DE LA SONDE EST RELIEE A LA MASSE DU CIRCUIT A MESURER ET QUE LA SONDE EST RELIEE AU VOLTMETRE ELECTRONIQUE Chaque fois que cela est possible utilisez de pr f rence le crochet ressort pour re lever une tension Le crochet doit tre mis en contact au point d sir alors que le ci cuit est hors tension Ainsi sans toucher la sonde vous pourrez faire des mesures d licates ou dangereuses Lorsque la mesure est termin e d connectez nouveau le circuit l essai et d chargez soigneusement les condensateurs qui peuvent se trouver en circuit avant de d connecter le crochet de la sonde Page 4 EE Quoique la r sistance l int rieur du corps de la sonde ne soit jamais port e un potentiel sup rieur 300 V lorsque la sonde est normalement reli e au voltm tre lectronique CE POTENTIEL PEUT ATTEINDRE 30 000 VOLTS SI ELLE N EST PAS RELIEE AU VOLTMETRE ELECTRONIQUE DEBRANCHEZ COMPLETEMENT VOTRE INSTALLATION POUR RELIER LA SONDE AU VOLTMETRE ELECTRONI QUE GARAN IE HEATHKIT GARANTIT TOUTES LES PIECES CONTRE TOUT VICE DE FABRICATION OU DEFAUT PENDANT UNE PERIODE DE 3 MOIS A COMPTER DE LA DATE DE LIVRAISON SI LES PIE
6. CES ONT ETE UTILI SEES NORMALEMENT SI CES CONDITIONS SONT REMPLIES LES PIECES CONSTATEES DEFECTUEUSES PAR NOS SERVICES SERONT REMPLACEES GRATUITEMENT CETTE GARANTIE NE S APPLIQUE QU A L ACQUEREUR INITIAL ET REMPLACE TOUTES AUTRES GARAN TIES IMPLICITES OU NON AINSI QUE LES OBLIGATIONS POUVANT EN RESULTER ET EN AUCUN CAS HEATHKIT NE PEUT ETRE TENU RESPONSABLE POUR DES BENEFICES ANTICIPES DES DOMMAGES CONSECUTIFS PERTE DE TEMPS OU AUTRES PERTES SUBIES PAR L ACHETEUR DECOULANT DE L ACHAT DU MONTAGE OU DE L UTI LISATION DE HEATHKIT OU DE PIECES S Y RAPPORTANT AUCUN REMPLACEMENT DE PIECES DEFECTUEUSES NE SERA EFFECTUE SI LEUR DETERIORATION EST LA CONSEQUENCE DE MANIPULATIONS INCORRECTES DURANT LE MONTAGE REMARQUE LA PRESENTE GARANTIE SERA ENTIEREMENT NULLE ET NOUS NE REMPLACERONS NE REPARERONS ET N ASSURERONS PAS L ENTRETIEN D INSTRUMENTS OU DE PIECES S Y RAPPORTANT DANS LESQUELS DE LA SOUDURE A BASE ACIDE OU DES PATES DECA PANTES AURONT ETE UTILIS ES For VTVM S with 1 5v Full Scale Range ASSEMBLING THE HEATHKIT no s HIGH VOLTAGE PROBE KIT ER H zen SPRING COO CCC LCL CCC CCC CCCCC ECC CCC EE t 1 PROBE BODY COUR SCREW 1090 MESONI RESISTOR es 4 Ce D wU HANDLE THE 1090 MEGOHM RESISTOR WITH CARE AS OUTLINED IN THE NOTE PACKED WITH THIS PART Remove the screw from one end and replace with the collar screw Screw the body spring onto the long part of the collar screw Slip
7. eg AC I Wi LL Instructions d assemblage de la SONDE THT SERRES 336 CORPS DE LA SONDE MONTAGE FACULTATIF DU CROCHET MANCHON ISOLANT SOUDEZ FLEXIBLE FICHE DE JACK E CORDON ROUGE Tous les prix sont sujets changements sans souvez pr avis La Compagnie Heathkit Ger te GmbH gt se r serve le droit d interrompre la fabrica tion de ses mod les ou d apporter des modifi Ke Set SOS cations aux mod les existants n importe PINCE crocopite quel moment sans qu elle soit tenue de mo difier ou faire modifier les appareils d j vendus CORDON NOIR HEATHKIT GER TE GmbH COPYRIGHT 1962 BY HEATH COMPANY USA TRANSLATION 1965 BY MEATHKIT 6079 Sprendlingen bei Frankfurt BEE rn Son o Robert Bosch StraBe Nr 32 38 COPYRIGHT 1952 BY HEATH COMPANY USA TRADUCTION FAITE EN 1965 PAR Tel 06103 68971 68972 68973 DEET HEATH COMPANY USA 900 595 490F 20 4 1965 Page 2 SEN INVENTAIRE ET NOMENCLATURE DES PIECES R f rence Quantit D signation 432 1 1 Connecteur 476 2 1 Corps de la sonde 2 47 1 R sistance de 1090 MQ 250 6 1 Vis collerette hexagonale 260 1 1 Pince crocodile 258 2 1 Crochet ressort 258 3 1 Ressort de pression 70 1 1 Manchon isolant 438 3 1 Prise de Jack 341 1 1 Longueur de cordon noir 341 2 1 Longueur de cordon rouge 331 6 Soudure en fil 900 595 490 F 1 Instructions d assemblage en frangais NB MANIPULEZ LA RESISTANCE DE 1
8. hout touching the probe turn power on take the reading turn the power off carefully discharge any high vol tage condensers which may be in the cireuit and remove the probe from the circuit While the conductors inside the handle and the test lead assembly never carry more than 300 volts when the probe is properly connected THESE PARTS WILL BE EX POSED TO THE FULL 30 000 VOLTS IF NOT CONNECTED TO THE VIVM INSTALL TIP spent WHEN DESIRED AIL DC ranges on the VIVM are now multiplied by 100 thus the 150 volt range becomes the 15 000 volt range ALTHOUGH MULTIPLYING THE 500V RANGE BY 100 GIVES 50 000V NEVER USE THE PROBE ON DC VOLTAGES ABOVE 30 000 VOLTS High voltages up to 30 000 Volts DC as encountered in television receivers may be applied to this test probe This probe increases the input resistance of the meter to 1100 megohms On the Volt position of the range switch a full scale reading of 500 Volts is obtained This permits measurements to be made in high resistance cireuits with negligible loading WARRANTY The Heath Company limits its warranty on any part sup plied with any Heathkit except tubes meters and rec tifiers where the original manufacturer s guarantee on ly applies to the replacement within three 3 months of said part which when returned with prior permission postpaid was in the judgment of the Heath Company de fective at the time of sale
9. robe Body 2 47 1 1090 Megohm Resistor 250 6 1 Hex Collar Screw 258 2 1 Tip Spring 258 3 E Body Spring 341 3 1 Heavy Test Lead 0 1 x Insulator Sleeve 436 3 1 Phone Plug CAUTION HIGH VOLTAGES ARE EX TREMELY DANGEROUS NEVER MEA SURE DC VOLTAGES IN EXCESS OF 30 000 VOLTS This probe is designed to permit high vol tage measurements to be made as safely as possible ALWAYS MAKE SURE THAT THE GROUND CLIP IS CONNECTED BETWEEN THE CHASSIS OF THE UNIT UNDER TEST AND THE VTVM AND THAT THE PROBE IS CONNECTED TO THE VTVM Wherever possible contact the high voltage by hooking the tip spring to the terminal un der test This should be done with the power turned off Then without touching the probe turn power on take the reading turn the power off carefully discharge any high vol tage condensers which may be in the circuit and remove the probe from the circuit While the conductors inside the handle and the test lead assembly never carry more than 300 volts when the probe is properly connected THESE PARTS WILL BE EX POSED TO THE FULL 30 000 VOLTS IF NOT CONNECTED TO THE VTVM INSTALL TIP SPRING WHEN DESIRED Se All DC ranges on the VTVM are now multiplied by 100 thus the 300 volt range becomes the 30 000 volt range and the 100 Volt range becomes the 10 000 Volt range NEVER USE THE PROBE ON DC VOLTAGES ABOVE 30 000 VOLTS High voltages up to 0 000 Volts DC as encountered in tele
10. vision receivera may Be applied to this test probe This probe increases the input resistance of the meter to 1100 megohms On the 3 Volt position of the range switch a full scale reading of 300 Volts is obtained This permits measurements to be made in high resistance circuits with negligible loading WARRANTY The Heath Company limits its warranty on any part sup plied with any Heathkit except tubes meters and rec tifiers where the original manufacturer s guarantee on ly applies to the replacement within three 3 months of said part which when returned with prior permission postpaid was in the judgment of the Heath Company de fective at the time of sale Theassembler is urged to follow the instructions exact ly as provided The Heath Company assumes no respons ibility nor liability for any damages or injuries sustained in the assembly of the device or in the operation of the completed instrument HEATH COMPANY Benton Harbor Michigan
Download Pdf Manuals
Related Search
Related Contents
Product User Manual 6~8面 - 成田市 Trevi GO 2000 WIFI Gesamtkatalog - Lovibond Tintometer Homecheck Professional Ground Stability Report User Guide FileMaker G0600 User's Manual Roberts Radio Elise Manual Utilizador FM3 Inverter Sensor Washing Machine Firmware User Manual Copyright © All rights reserved.
Failed to retrieve file