Home
sable slow speed e-type air motor maintenance and cleaning manual
Contents
1. SABLE IN DUST SABLE SLOW SPEED E TYPE AIR MOTOR MAINTENANCE AND CLEANING MANUAL Please retain this manual as your proof of purchase MODEL NO MAXIMUM RPM Q 1600101 25 000 1600102 5 000 1610110 20 000 1600110 20 000 Special Precautions 1 Always exercise extreme caution when operating your Slow speed 2 Always inspect your Slowspeed thoroughly before each use 3 Always use PPE Proper Protective Equipment when operating and cleaning your Sable Slowspeed See your Occupational Health and Safety Act or other safety ordinances for specific instructions 4 If product is dropped your dealer should be contacted it is recommended that you do not use 5 Contact your dealer right away if any problem should occur with any of your Sable products 6 Sterilize before first time use and before every subsequent use thereafter 7 This product is for use by a Dentist or trained professional in the dental field FEATURES 1 Air Motor conforms to International Standard Organization ISO specifications 2 Accepts all E Type ISO 3964 compatible attachments 3 Autoclavable SPECIFICATIONS 1 Maximum Air Pressure 45 PSI 2 Connection with Attachments ISO Standard 3 Method of Sterilization Autoclave 4 Air hose connection Midwest type 4 hole HOW TO USE 1 Use only Clean Dry Compressed Air A 1 Connect to air hose Ensure rubber gasket is in place 2 Select Forward or Reverse Rotation Caution F
2. e dentaire CARACT RISTIQUES 1 Le moteur air r pond aux exigences des normes ISO Organisation internationale de normalisation 2 Accepte les attachements du type E compatible ISO 3964 3 Peut passer l autoclave SP CIFICATIONS 1 Pression d air maximum 45 Ib po 2 Connexion avec attachements Conforme aux normes ISO 3 M thode de st rilisation Autoclave 4 Connexion pour tuyau d air Type Midwest 4 trous MODE D EMPLOI A 1 Utiliser seulement de l air propre sec et compress 2 Raccorder au tuyau d air assurer que le joint d tanch it est bien en place 2 S lectionner le mode de rotation vers l avant ou invers e Attention Pour la vitesse maximale l anneau de s lection doit tre enti rement en position R ou F 3 Attachement du type E contre angle ou conique Tirer l attachement appuyant sur le bouton de d clencheur situ l ext rieur du moteur air Faire preuve de caution en utilisant Pour l utilisation par un membre du personnel form seulement LUBRIFICATION N UTILISER QUE DU LUBRIFIANT POUR PIECE MAIN AUTOCLAVABLE 1 Retirer le moteur du tuyau air 2 Appliquer du lubrifiant dans le tuyau air Fig 1 7 ey Air 3 Raccorder le moteur au tube a air 4 Faire fonctionner le moteur la vitesse normale pendant 10 secondes 5 Essuyer l exc s d huile de la surface du moteur PROCEDURE DE STERILISATION L AUTOCLAVE 1 E
3. or maximum speed selection ring must be fully in F or R position 3 Attachment of E Type Contra Angles or Nosecones Slide Attachment onto shaft of Air Motor until locked in place 4 Removal of Contra Angles or Nosecones Pull Attachment pushing release button located on the exterior of Air Motor Note Exercise caution when operating For use only by trained personnel LUBRICATION USE ONLY AUTOCLAVABLE HANDPIECE LUBRICANT 1 Remove Handpiece from air hose 2 Apply lubricant into drive air tube Fig 1 sisi dos 3 Attach Handpiece to air hose FM 4 Run Handpiece at normal speed for 10 seconds 5 Wipe off excess oil from Handpiece surface AUTOCLAVING PROCEDURE 1 Wipe off debris on the Handpiece surface with alcohol soaked cloth 2 Lubricate the Handpiece 3 Autoclave for 20 minutes at 135 C ATTENTION This is a precision instrument Do not drop or apply excessive force when handling CYCLES The Attachment Head can be subject to 250 cycles Performed Sterilization Process per EN ISO 7785 2 requirement 5 5 before showing signs of deterioration WARRANTY INFORMATION The Sable Slow Speed Handpiece is warranted to be free of manufacturing defects for a period of 12 months from date of purchase Warranty is conditional on proper use and maintenance of Handpiece Warranty is limited to repair or replacement at manufacturers discretion Under no circumstances will the manufacturer be held responsible for incremen
4. ssuyer les d bris sur la surface du moteur avec un linge imbib d alcool 2 Lubrifier le moteur Se r f rer au mode d emploi pour la lubrification 3 Passer en autoclave 135 C pendant 20 minutes ATTENTION Ce produit s agit d un instrument de pr cision Ne pas chapper ou exercer une force excessive lors de la manipulation CYCLES L attachement la t te peut tre soumis e 250 cycles Processus de st rilisation effectu conform ment l exigence 5 5 du EN ISO 7785 2 avant de montrer des signes de d gradation INFORMATION SUR LA GARANTIE La pi ce main basse vitesse de Sable est garantie contre tout d faut de fabrication pour une p riode de 12 mois apr s la date d achat La garantie est conditionnelle l utilisation et l entretien ad quats de la pi ce main La garantie se limite la r paration ou au remplacement de la pi ce d fectueuse la discr tion du fabricant Le fabricant ne peut en aucun cas tre tenu responsable de dommages indirects Veuillez contacter le distributeur autoris pour la r paration sous garantie Sable Industries Inc N de dossier Sable Slow Speed Motor 100 avenue Campbell Suite 5 PPIS1004 Rev E Kitchener Ontario Canada Date 07 22 2014 N2H 4X8 IMPRIM AU CANADA
5. tal or consequential damages Please contact point of purchase authorized distributor for warranty repair Sable Industries Inc File no Sable Slow Speed Motor 100 Campbell Ave Suite 5 PPIS1004 Rev E Kitchener Ontario Canada Date 07 25 2014 N2H 4X8 PRINTED IN CANADA lt SABLE INDUS T MANUEL D ENTRETIEN ET DE NETTOYAGE DES MOTEURS A BASSE VITESSE TYPE E DE SABLE Veuillez conserver ce manuel comme preuve d achat N DE MOD LE R MIN MAXIMUM 1600101 25 000 1600102 5 000 1610110 20 000 Q 1600110 20 000 Pr cautions sp ciales A 1 Toujours faire preuve d une extr me prudence en utilisant votre appareil basse vitesse 2 Toujours inspecter votre appareil base vitesse avant chaque utilisation 3 Toujours utiliser de l EPI quipement de Protection Individuelle en utilisant et nettoyant votre appareil basse vitesse de Sable Voir votre Loi sur la sant et la s curit au travail ou autres ordonnances de s curit pour des instructions sp cifiques 4 Si le produit est chappe 1l est recommand que vous contactiez votre concessionnaire et que vous cessez de l utiliser 5 Contacter votre concessionnaire imm diatement pour tous probl mes que vous rencontrez avec vos produits Sable 6 St riliser avant la premi re utilisation et avant chaque utilisation subs quente par la suite 7 Ce produit doit tre utilis par un dentiste ou un professionnel qualifi dans le domain
Download Pdf Manuals
Related Search
Related Contents
CTA Digital 3DS-CD battery charger Education à la santé en milieu scolaire - Livre Manuale di installazione e manutenzione Bus di campo MANUAL DEL OPERADOR POPGROUP Manual Samsung WB5000 User Manual PPDM3 - Manuals - Qualitycaraudio.com ESTUFA CATALÍTICA A&E Patio Awnings - Bryant RV Services Series 90-70 Programmable Controller Data Sheet Copyright © All rights reserved.
Failed to retrieve file