Home
SLV Lighting North America
Contents
1. The fixture may only be operated with a complete and intact protection glass Operate the product only when it functions properly AN In case of a malfunction do NOT touch the product or operate it further Disconnect the product from the power supply by an external switch or by the fuse If touched or further operated there is danger from electric shock burning or fire A malfunction exists when Visible damages appear The product does not work properly e g flickering Smoke steam or crackling sounds appear Smell of burning is recognisable An overheating is recognisable e g by discolouration of adjacent surfaces Operate the product only after maintenance and examination by a licensed electrician 2 USE AS DIRECTED This product serves exclusively lighting purposes and may Only be used with a voltage of 120V 60Hz Only be operated when firmly mounted Not be exposed to strong mechanical loads or to strong contamination Only be installed and operated after a condition inspection if the product is dirty or has been moistened through storage Not be modified or converted 3 OPERATION ie Exchange the light source always before it reaches its lifespan to avoid personal injuries or damages of the fixture or other objects Disconnect the product from the power supply before you exchange the bulbs Let the light source cool down before replacement There exists danger of
2. burning Use only light sources that are approved for the product Approved light sources are indicated on the type label Other types of light sources may cause fire risk damage the product or lead to malfunction Replacing the light source Remove the protection glass Remove the used bulb Use the suction tool to insert the bulbs Insert the bulb with a quarter turn to the right Put the protection glass back on Check and clean the gasket after each opening of the fixture The bearing surface of the gasket must be free of dirt These measures ensure that the IP class is maintained Note the proper fit for the gasket 4 MAINTANANCE AND CARE The following environmental influences may have unwanted effects on the surface of the product acid rain and sour soil high salt content in the air thawing salt cleaning agents fertilizer especially in flowerbeds other chemical substances e g herbicides Protect the product by adequate means to avoid unwanted changes of the surface AN Disconnect the product from the power supply and let it cool down before you clean the product If disregarded there may be danger of electric shock or by burning when cleaning the product Cleaning Clean the product on a regular basis using a slightly moistened soft and fluff free cloth Please also note additional supplied notes on maintenance and care 5 ADDITIONAL IMPORTANT NOTES Storage The product must be s
3. sur la plaque d identification D autres ampoules peuvent entrainer un incendie un dysfonctionnement ou bien un d dommagement du produit Changement d ampoule Enlevez le verre de protection Enlevez ampoule us e Utilisez une ventouse pour mettre les ampoules Mettez ampoule dans la douille en le tournant d un quart de tour droite Fixez de nouveau le verre de protection Contr lez et nettoyez le joint chaque ouverture du lampadaire La surface du joint doit tre propre C est une mesure pour garantir la protection IP Veillez ce que le joint soit bien mis 4 ENTRETIEN ET NETTOYAGE Les influences suivantes peuvent avoir des cons quences ind sirables sur la surface du produit les pluies acides ou le sol acide une haute teneur en sel dans l air du sel de d neigement des nettoyants basiques et acides Les engrais particuli rement dans les platebandes de fleures d autres substances chimiques par ex des produits phytosanitaires Prot gez le produit avec des mesures ad quates pour viter des modifications de la surface A Coupez toutes les sources d alimentation et mettez le produit hors tension avant de proc der toutes mesures d entretien ou de nettoyage Laissez le produit tout d abord refroidir En cas de non respect des indications signal es existe au cours du nettoyage un danger de d charge lectrique ou bien br lures Nettoyage Veillez nettoyez le produit uniquement avec
4. un chiffon doux l g rement humidifi et ne peluchant pas Veuillez respecter S V P les instructions de nettoyage et d entretien ventuellement ci jointes 5 AUTRES INSTRUCTIONS IMPORTANTES Stockage Le produit doit tre stock dans un lieu sec l abrie de salet salissure et de toute charge m canique Garantie Dans le cas d une r clamation de garantie veillez vous adresser votre marchant sp cialis 6 INSTALLATION seulement par un lectricien prouv A Coupez l interrupteur g n ral de votre installation reps la ligne de rattachement concern e avant de commencer tout travail existe danger de d charges lectriques mortelles Utilisez uniquement les l ments livr s avec ce produit ou bien d crits comme accessoires Autrement une parfaite s curit de fonctionnement ne peut tre assur e Il se peut qu il un danger mortel ou d incendie V rifiez si le produit contient des l ments en vrac Si c est le cas alors que la pr sence de ces l ments n est pas signal e explicitement le produit ne doit pas tre install ou mis en fonction Les parties touchables peuvent tre apr s connexion sous tension Danger de d charge lectrique mortelle Utilisez le mat riel de fixation livr si et seulement si ce dernier est appropri au fond de montage Dans le cas contraire utilisez des l ments de fixations appropri es Une utilisation d l ments de montage non app
5. 54U 66U 76U 05 2012 SLV Lighting North America 5731 Benjamin Center Drive Tampa FL 33634 USA Tel 813 349 1900 Technical Details are subject to change SLV Lighting North America FRAN AIS MODE D EMPLOI POUR APPLIQUE PLAFONNIER vie peut tre presente par un choc electrique un incendie ou des produits tombants quand les points suivants ne sont pas respect s Ce luminaire doit tre installe selon les normes du Code Electrique National Code Electrique Canadien selon la province reglements local et installe par un electricien professionnel 1 CONSIGNES DE SECURITE L installation le montage et les travaux de bronchement doivent tre effectu s seulement par un personnel professionnellement qualifi et agr e Ne couvrez pas le produit N emp chez pas l air de circuler N accrochez ni ne fixez rien au produit surtout pas de d coration Gardez hors de port e des enfants Le luminaire peut tre mis en fonction avec un verre de protection intacte Utilisez le luminaire uniquement dans le cas o il fonctionne correctement 1 En cas de dysfonctionnement le produit ne doit pas tre touch Eteindre le produit par l interrupteur externe ou bien d verrouiller la ligne au fusible Dans le cas d un contact avec le produit et d une poursuite de son fonctionnement malgr l tat de dysfonctionnement persiste un danger mortel par d charge lectrique ou danger de brulures Un dys
6. SLV Lighting North America 7514540 7514640 7514740 INSTALLATION INSTRUCTIONS FOR Toe Dei eee e ES111 GU10 ES111 GU10 ES111 GU10 MODE D EMPLOI POUR nus me re WALL AND CEILING FIXTURES Protection against foreign objects gt 1 cm Protection against splashing water from all directions Protection contre les corps trangers durs gt 1 cm Protection contre les claboussures provenant de toute la direction ROX OUT CEILING 751454U WALL 751464U UP DOWN 751474U 229756U 66U 76U 09 2012 SLV Lighting North America 5731 Benjamin Center Drive Tampa FL 33634 USA Tel 813 349 1900 Technical details are subject to change Les d tails techniques sont sujets a des changements SLV Lighting North America ENGLISH INSTRUCTION MANUAL FOR WALL AND CEILING FIXTURE A WARNING Life threatening danger due to electric shock danger of fire and danger from falling objects may exist if the following is not respected This luminaire must be installed in accordance with the National Electric Code Canadian Electrical Code State provincial and local regulations by a licensed electrician 1 NOTES ON SAFETY Installation mounting or works on the electrical connection may only be carried out by a licensed electrician Do not cover the product provide free air circulation Do not hang or fasten anything on the product especially no decoration Keep children away from the product
7. allation on a wall Make sure that the product is mounted on a stable even and tilt fixed background The light exit should be placed at least so far from the illuminated surface as indicated as minimum distance on the type plate of the luminaire aj nf 31 5 in Pay special caution to easily inflammable objects e g foliage Separate Installation Steps Notice Do not try to seal the product yourself using additional silicon or another sealant Secure the mounting plate to the electrical junction box located in the ceiling or wall Direct the fixture wire leads through the mounting plate and silicone gasket connect with the 120V wires in the junction box Secure the fixture and gasket to the mounting plate using the silicone ring washer and a screw on each side of the canopy Electrical Connection The product must be able to be separated by an external switch and electrical circuit breaker from the 120VAC supply Switch off 120VAC power before doing any work Connect the black wire live conductor the white wire neutral conductor and the green wire protective ground conductor of the 120VAC mains supply with the corresponding wires of the luminaire Black L White N and GRND Green wires Inserting the light source Insert the bulb lamp into the socket and turn to lock in place Check if the product functions properly and is securely fixed The product is now ready for operation 7514
8. fonctionnement existe si des endommagements apparentes surviennent le produit ne fonctionne pas correctement p ex clignot Le produit d gage une fum e abondante ou fait un bruit de p tillement une odeur de br l se fait sentir une surchauffe se fait remarquer p ex changement de couleur aussi sur les surfaces voisines La mise en fonction de nouveau ne doit tre effectu e qu apres une r paration et v rification par un personnel qualifi et autoris 2 AUTILISER COMME INDIQUE Ce produit sert seulement aux fins d clairage et doit tre pr vu pour une tension de 120V 60Hz Ne pas tre pris en service que sous montage fixe ne pas tre expos a des forces m caniques fortes ou bien des salet s et salissures tre install seulement qu apr s examen par un personnel qualifi si le produit a t stock dans un entrep t humide ou sale ne pas tre transform ou modifi 3 OPERATION i A fin d viter des d g ts aux personnes au luminaire ou d autres choses veuillez changez l ampoule temps et avant la fin de sa long vit Coupez d abord le produit de toutes les sources d alimentation et mettez le hors tension laissez l ampoule refroidir avant de le changer existe sinon un danger de br lures a la surface chaude de l ampoule Veuillez utiliser pour le luminaire seulement des ampoules admissibles Des donn es pour ampoules sont signal es
9. ropri es peut entrainer un danger mortel ou des blessures caus es par une chute du produit Deballage Volume de livraison Enlevez avec soin le produit de son emballage et cartez tous les l ments qui ont servi sa protection lors du transport Contr lez l int grit du produit apr s lavoir extrait de son emballage et avant tout retraitement Lieu d installation 751454U Le produit est seulement appropri pour le montage au plafond 751464U 76U Le produit est seulement appropri pour le montage au mur Veillez ce que le produit soit mont de mani re stable et r sistante au basculement La distance entre la sortie de lumi re et la face illumin e devrait au moins tre tant que la distance minimale indiqu e sur l tiquette du type du luminaire Q t8r g 5in Soyez prudent avec les mati res inflammables comme feuillage etc Etapes successives pour installer le luminaire Indication Ne colmatez pas le produit de votre initiative en ajoutant de silicone ou outre mat riel de colmatage Fixer la plaque de montage la bo te de jonction lectrique situ dans le plafond ou au mur a connexion directe 120V m ne travers le joint en silicone dans le luminaire Fixer le dispositif et le joint la plaque de montage en utilisant une bague d tanch it de silicone une rondelle et une vis de chaque c t de la voilure Raccordement lectrique Le produit doit po
10. tored in a dry and clean environment Do not strain the product mechanically during storage Warranty In case of a warranty contact your dealer 6 INSTALLATION only by a licensed electrician AN Switch off the mains or respectively the connection lead before doing any works There exists mortal danger from an electric shock Use only parts which are supplied with the product or are described as accessories Otherwise the product or the whole installation may not be secure Danger for life or danger of fire may exist Inspect the product for loose parts inside the housing When there are loose parts inside the housing and they are not described as necessary in the manual the product may not be installed or operated The housing may be voltage carrying Danger of electric shock Use the supplied fastening material only when it is suited for the installation background If this is not the case use only fastening material suiting the installation background When using fastening material that is not suitable there may be danger from falling objects Unpacking Consignment Fastening materials Carefully take the product out of the packaging removing any transport safeguards Before disposal of the packaging material make sure that all components of the product are removed Installation place 751454U The product is solely suited for installation on a ceiling 751464U 76U The product is solely suited for inst
11. uvoir tre s par par un commutateur externe et un disjoncteur lectrique du 120VAC provision Couper 120VAC avant de faire n importe quel travail Connecter le fil noir vit le conductor le fil blanc le conductor neutre et le fil vert GRND le conductor de terre protecteur S du 120VAC le reseau lectrique la provision avec les fils correspondants du luminaire Noir L le Blanc N et GRND Vert les fils Maintenant attacher le baldaquin de retour au crochet montant Ne pas oublier d appliquer les rondelles de toothed Insertion de la source de lumi re Ins rez l ampoule lampe dans la douille et tournez pour verrouiller en place Le produit est maintenant pr t pour l op ration 751454U 66U 76U 09 2012 SLV Lighting North America 5731 Benjamin Center Drive Tampa FL 33634 USA Tel 813 349 1900 Les d tails techniques sont sujets a des changements