Home
Model T-617HDN
Contents
1. NOTE Wire size increases as gauge number decreases MINIMUM GAUGE FOR EXTENSION CORDS CORD LENGTH 25 FEET 50 FEET 100 FEET 150 FEET GAUGE 12 12 10 8 Grounding Instructions DANGER Improper grounding can result in electrical shock In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current The air compressor must be grounded This compressor is for use on a nominal 120 volt circuit and is equipped with a grounding wire and appropriate grounding plug that looks like the plug illustrated The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances Make sure that the compressor is connected to an outlet having the same configuration as the plug No adapter should be used with this product Inspect the plug and cord before each use Do not use compressor if there are signs of damage GROUNDED OUTLET GROUNDED OUTLET BOX GROUNDING PIN DANGER Improper installation of the grounding plug can result in electrical shock If repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with the green with or without yellow stripes insulation is the grounding wire and must be connected to the grounding pin Check with a qualified electrician if the grounding instructions are not completely understood or if unsure unit is properl
2. 2 Inspect hose plug and cord for signs of damage before use Do not use if a deficiency is found Contact your nearest service center for replacement parts Never operate a damaged unit 3 Do not tamper with the safety valve It has been factory set Any adjustment of this valve could cause serious injury 4 This air compressor needs no lubrication Applying oil to any part could result in polluted air delivery to the air handling equipment 5 Compressed air must never be aimed at anyone because it can cause serious injury Keep children away WEAR EYE PROTECTION 6 All air compressors generate heat even under normal operating conditions To avoid serious burns never touch the air compressor during or immediately after operation 7 When unit is not in use wrap cord securely and store in dry place Do not abuse cord or plug 8 Before servicing cleaning or removal of any part shut off power and relieve pressure from tank 9 This system produces 125 PSI To avoid rupture and injury do not operate this pump with components rated less than 125 PSI working pressure including but not limited to spray guns hose and hose connections without pressure regulator If warranty service or repair is needed contact your nearest authorized service center If one does not exist in your area contact the factory Unauthorized repairs or teardown of the unit will void the factory warranty 2 SET UP Location of Air Compressor Ope
3. Air Filter Inspect air filter before each use Clean filter BE with soap and water as necessary Squeeze Q excess moisture from filter and allow to dry before Se S re installing If filter becomes clogged or damaged Es replace it A WARNING Never clean air filter with a flammable liquid or solvent Explosive vapors may accumulate in the air tank and cause an explosion resulting in serious injury or death CAUTION Do not operate air compressor without air filter Storage Tank The storage tank should be drained after each use or after every four hours of operation to prevent condensation build up and corrosion inside the tanks To drain tank slowly and carefully D open drain fitting tip unit upright and allow water to drain out Always drain tank before storing compressor DO NOT over tighten drain valve when closing The drain valve on this tank seals primarily through the o ring seal Over tightening the valve can damage the o ring and may cause premature failure To prevent damage stop closing the valve as soon as air can no longer be heard escaping from the valve or when finger tight NOTE When draining tank watch for debris rust particles If there appears to be debris in water contact your dealer for possible tank replacement The appearance of rust inside the tank will compromise its ability to hold pressure and can cause bursting WARNING Do not weld on the air tank of this comp
4. con conexi n a tierra apropiado El enchufe debe ser usado con un tomacorriente que al ser instalado haya seguido las leyes y ordenanzas locales para efectos de conexiones a tierra El tomacorriente debe tener la misma configuraci n del enchufe No use un adaptador No le haga modificaciones al enchufe que se provee Si no encaja bien en el tomacorriente existente un electricista profesional debe instalar el tomacorriente correspondiente Inspeccione el enchufle y el cable cada vez que use la unidad No use el compresor si presenta se ales de aver as TOMACORRIENTE CONECTADO A TOMACORRIENTE CONECTADO A TIERRA ESTUCHE CLAVIJA CONECTADA A TIERRA A PELIGRO Si la instalaci n del enchufle conectado a tierra es hecha incorrectamente puede producirse un choque el ctrico Si necesita reparar o reemplazar el cable o el enchufe no conecte el cable a tierra a ninguno de los dos gajos planos del terminal El alambre con el aislamiento verde con o sin rayas amarillas es el alambre conectado a tierra Consulte con un electrista calificado si no comprende completamente las instrucciones que se dan aqui para hacer la conexi n a tierra o si no est seguro de haber hecho la conexi n a tierra en forma apropiada COMPRESSOR PARTS LIST EXPLODED VIEW AND PARTS LIST Item an Part No Component Description Qt
5. de cualquier tipo en los tanques puede ocasionar la perdida de la garantia Si algun servicio de garantia o cualquier reparo es necesario comuniquese con su distribuidor m s cercano Si este no existe comuniquese con la f brica Cualquier desmontaje desautorizado en la unidad cancelara la garantia de la f brica 14 PRECAUTIONS D EMPLOI A ATTENTION Veuillez lire attentivement ce manuel d utilisation avant de vous servir de ce compresseur d air 1 Le compresseur doit tre utilis dans un endroit sec propre et bien a r 2 Avant l emploi examiner le tuyau la fiche et le fil lectrique pour rep re tous signes de d terioration Ne pas utiliser l appareil en cas de d faut de fonctionnement ou de mat riel Addressez vous au service entretien le plus proche pour obtenir des pi ces de rechange Ne jamais utiliser un appareil d fectueux 3 Ne pas modifier la pression de la soupape de s ret elle a t r gl e en usine Tout autre r glage pourrait entr iner un risque de blessure grave 4 Ce compresseur d air ne n cessite aucune lubrification Le graissage des pi ces risque de polluer l air comprim alimentant les accessoires pneumatiques 5 Lair comprim ne doit jamais tre point sur une personne car il peut entrainer des blessures graves Eloigner les enfants de l endroit de travail PORTER DES LUNETTES DE PROTECTION 6 Tous les compresseurs d air produisent de la chaleur m me dans des conditions de
6. les r glements et les ordonnances locales La prise doit avoir le m me configuration que la fiche Ne pas utiliser d adaptateur Ne modifiez pas la fiche qui vous est fournie Si celle ci ne s adapte pas la prise disponible il faut faire installer la prise correcte par un lectricien Inspectez la fiche et ie fit lectrique avant chaque utilisation N utilisez pas le compresseur d air si ces lements sont endommag s PRISE AVEC PRISE DE Ha erse AVEC PRISE DE TERRE BOITE FICHE DE TERRE DANGER Une mauvais installation de la fiche de terre peut causer une lectrocution S il faut r parer ou changer le fil lectrique ne raccordez pas le fil de terre n importe quelle fiche plate de terre 17 Le fil recouvert d un isolant vert avec ou sans raies jaunes est le fil de terre Faites v rifier l installation par un lectricien qualifi si vouscomprenez pas enti rement les instructions concernant la mise a la terre ou si vous n tes pas s r que l appareil soit correctement mis a la terre FONCTIONNEMENT Soupape de s ret La soupape de s ret est concue pour que la pression qui se trouve dans les r servoirs d accumulation n exc de pas 165 PSIG ATTENTION N essayez pas de modifier ou de supprimer la soupape de s ret Protecteur de surchauffe Le moteur du compresseur est quip d un protecteur de surchauffe Si le moteur vient surchauffer le protecteur
7. Assembly 50 669470 540 Tank Assembly Rl l 11 OPERACION VALVULA DE SEGURIDAD La v lvula de seguridad ha sido dise ada para prevenir que la presi n en los tanques de almacenamiento exceda 140 PSIG PRECAUCION No altere ni trate de eliminar la v lvulade seguridad PROTECTOR TERMICO PARA SOBRECARGA El motor del compresor est equipado con un protector t rmico para sobrecarga Si el motor se llegara a recalentar este protector apagar el motor Si esto ocurre apague la unidad y deje que el motor se enfr e aproximadamente unos 5 minutos NOTA La presi n del tanque debe estar bajo 110 PSIG para que el compresor arranque Encienda la unidad para volver a arrancar el compresor Si elcompresor no arranca revise la unidad en busca de fusibles quemados el compresor puede necesitar m s tiempo para enfriarse Si el protector de sobrecarga apaga el motor frecuentemente podri a ser que hay voltaje bajo Indicaciones comunes de un voltaje bajo son 1 El motor no llega a su capacidad y velocidad 2 Los fusibles y el cortacircuitos se activan cuando searranca el compresor 3 Las luces bajan su intensidad al arrancar el compresor permanecen amortiguadas 4 Otros aparatos operados por el motor no funcionan en forma apropiada 5 Hay demasiados aparatos operados por el motor en el mismo circuito FUNCIONAMIENTO DEL INTERRUPTOR DE PRESION El compresor es operado por medio de u
8. H RESPECT TO THE PRODUCT AND IT S PARTS INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Thomas total liability for any and all claims damages losses and injuries arising out of or relating to any breach of warranty shall not exceed the purchase price of the product IN NO EVENT WHETHER IN CONTRACT OR TORT OR OTHERWISE SHALL THOMAS BE LIABLE FOR LIQUIDATED INDIRECT EXEMPLARY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES EXPENSES OR COSTS INCLUDING BUT NOT LIMITED TO 1 LOSS OF PROFITS BUSINESS OR GOODWILL 2 LOSS OF USE OF EQUIPMENT OR FACILITIES OR 3 LOSS RESULTING FROM UNUSABLE MACHINERY OR FACILITY DOWNTIME HOWSOEVER CAUSED AND EVEN IF THE POTENTIAL FOR SUCH DAMAGES WAS DISCLOSED AND OR KNOWN The remedy provided in this Limited Warranty for defective product is purchaser s sole and exclusive remedy subject to your state law Further this Warranty gives you specific legal rights and you may also have other rights which may vary from state to state If you believe warranty service is needed contact your nearest authorized service center If one does not exist in your area please contact the manufacturer Thomas Products Division of a Gardner Denver Thomas Inc C O Customer Service D 3524 Washington Avenue a O MAS Sheboygan Wisconsin 53081 Phone 800 558 7721 A Gardner Denver Product cei ae li www thomasairpac com 22
9. ONES A O cate 115V 60Hz Requisitos del Fusibles tcs eine de 10A Regulaci n de Valvulas de Seguridad 140 PSIG 965 3KPa Desplazamiento de Aire 1 70 CFM 48 LPM Descarga de Aire 0 90 CFM 100 PSI 25 48 LPM 689 5 KPa Amps a Presi n de Trabajo sussu nine up 3 9 A Control Autom tico Comienza 98 D I 675 7 KPa TEE Para 122 PSIG 841 2 KPa Tama o del Tanque essa ir EME 2 Gal POS EE 32 Ibs Cable conducto vieran Avena ia nen ie 6 pies 1 83 M PSI Libras Por Pulgadas Cuadradas CFM Pies Cubicos Por Minuto DISPOSICION DE LA UNIDAD UBICACION DEL COMPRESOR DE AIRE Haga uso del compresor de aire en un area limpia seca y bien ventilada EI filtro de aire debe mantenerse libre de obstrucciones que pudieran reducir el flujo de aire que recibe el compresor El compresor de aire debe ubicarse por lo menos a 12 de paredes y otras obstrucciones que puedan interferir con el flujo del aire 1 Saque el compresor de aire de la caja de cart n y col quela a un lado 2 Instale las 4 patas de caucho con los tornillos incluidos en el kit de accesorios como se muestra 3 Cierre la v lvula de drenaje del tanque 4 Quite el tap n de leng eta anaranjado del puerto de admisi n en la cabeza del compresor e instale el filtro de admisi n que se proporciona en el kit de accesorios 5 Quite 2 tornillos de cabeza e instale la manija con los accesorios del
10. PSiG 965 3 KPa Volume d air d place menti daim 1 70 CFM 48 LPM D bit d Alain 0 90 CPM 100 PSI 25 48 LPM 689 5 KPa Amp res quand l appareil est sous pression 3 9 AMP Contr le automatique D marre 98 PSIG 675 7 KPa UE S arr te 122 PSIG 841 2 KPa POS RTS eb keane Rae ae 32 livres Contenance des FESCMVOIS eeviocononioncinssnorr carcelaria 2 gallons PUG l Le UE 6 pieds 1 83m PSI Livres par pouce carr CFM Pieds cubes par minute USAGE INSTALLATION Emplacement du compresseur d air Faites fonctionner le compresseur d air dans un endroit propre sec et bien er Le filtre air ne doit jamais tre bouch ce qui r duirait le d bit d air au compresseur Le compresseur d air doit tre plac Am 12 pieds au moins de murs ou d autres l ments d obstruction qui pourraient interf rer avec le d bit de Pair 1 Retirer le compresseur d air du carton et le placer sur sa partie lat rale 2 Monter les 4 pieds en caoutchouc l aide des vis fournies avec l ensemble d accessoires comme indiqu 3 Fermer le robinet de vidange du r servoir 4 Enlever 2 vis de t te et installer le levier de mance uvre l aide du mat riel fourni avec l ensemble d accessoires 5 Activer placer en mode automatique ou d sactiver le levier sur le pressostat en position OFF 6 Relier le tuya
11. S PARA LOS OJOS 6 Todos los compresores de aire generan calor aun bajo condiciones de operacion normales Para evitar quemaduras graves no toque el cabeza ni los componentes del escape del compresor durante la operaci n o inmediatamente despu s de ella 7 Cuando la unidad no est en uso enrolle el cablealrededor del compresor y gu rdelo en un lugar seco No maltrate el cord n 8 ANTES DEL SERVICIO LA LIMPIEZA 0 EL DESMONTAJE DE CUALQUIER PIEZA APAGUE LA UNIDAD Y ALIVIE LA PRESION 9 ESTE SISTEMA PUEDE PRODUCIR HASTA 9 5 k Jom 135 psi PARA EVITAR RUPTURAS DE COMPONENTES Y LESIONES CORPORALES NO OPERE LA UNIDAD CON ACCESORIOS POR EJEMPLO PISTOLAS DE PULVERIZACION MANGUERAS Y CONECTORES DE EZ Ane si PRESION NOMINAL DE TRABAJO SEA INFERIOR A 9 5 kg cm 135 psi Si se requieren reparaciones o servicio de garantia p ngase en contacto con el centro de servicio autorizado m s cercano Si no dispone de un centro p ngase en contacto con la f brica Las reparaciones o el desmontaje de la unidad sin autorizaci n anular n la garant a de f brica APLICACIONES Este compresor es ideal como unidad neum tica primaria o secundaria para pr cticamente cualquier tipo de operaci n Especialmente indicado para talleres garajes y f bricas en donde el uso continuo exige gran fiabilidad EL MANTENIMIENTO GENERAL Y SERVICIO Lea y entienda la informaci n de este maual del propletario del compresor que opera ESPECIFICACI
12. accedcnasanccncesseansceenedceusntecedendestecnenedsaneds 10A Safety Valve Setting cccceeescesseeessseeeeeeeeeesseeseeneneeeees 140 PSIG 965 KPa Air Displacement conmmonnccconnnnonnnnnnnnernn nn rra 1 75 CFM 49 5 LPM Air Delivery in nnrrnrrnnerrennenennennnnnnnee 90 CFM 100 PSI dat vue dda ange deeg SEENEN 25 48 LPM 689 5 KPa Amps at Working Pressure ss snsssnssessnrensnnenns 3 9 A Automatic Control sise Starts 98 PSIG SEN 675 7 KPa deeg Eed Stops 122 PSIG Eege ee 841 2 KPa Tank SiZ eege dien sue eg ode gedo bie a dde ad ad 2 Gal Shipping Ee LE 32 Ibs GO E 6 ft 1 83 M Sound Level ccc cece cece ssnsneennnneenennneeennnnennnnneeennnneeennnennnnnee 60 dB PSI Pounds Per Square Inch CFM Cubic Feet Per Minute KPa Kilopascals LPM Liters Per Minute APPLICATION Ideal as primary or secondary air source for almost any operation the Renegade T 617HDN is particularly suitable for shops garages and factories where repetitive use demands high reliability The T 617HDN will operate 1 Finish Nail Guns Visit www thomasairpac com for more information SAFETY FIRST U This symbol points out important safety instructions which if not followed could endanger the personal safety and or property of yourself and others Read and understand the information in this owner s manual and the engine owners manual before operating 1 The compressor should be located in a dry clean and well ventilated area
13. de surchauffe arr tera le moteur Si cela arrive mettez le levier marche arr t sur la position arr t et laissez le moteur se refroidir pendant environ cinq minutes REMARQUE La pression du r servoir doit tre inf rieure 110 PSIG pour que le compresseur puisse red marrer Red marrez le compresseur en mettant le levier marche arr t la position marche Si le compresseur ne d marre pas v rifiez les fusibles pour voir s ils n ont pas saut il se peut que le compresseur ait besoin de plus de temps pour refroidir Si le protecteur de surchauffe arr te fr quemment le moteur cela peut venir d un faible voltage Les signes habituels d un faible voltage sont les suivants 1 Le motteur manque de puissance ou ne peut atteindre la vitesse normale 2 Les fusibles ou le disjoncteur sautent lorsque le compresseur d marre 3 Les lumi res des lampes baissent ou restent faibles lorsque le compresseur d marre 4 D autres appareils moteur ne marchent pas correctement 5 Trop d appareils moteur sont sur le m me circuit lectrique 18 COMPRESSEUR DE PRESSION Le compresseur fonctionne par un leveir en action auto ferm au dessus de la c t de commutateur de pression En tournant le levier la position horizontal e le compresseur d marrera et cessera automatiquement l interieur de la position de commutateur de pression Le commutateur de pression est fait dans la fabrique et ajust pour mettre en marche le com
14. fonctionnement normales Afin d eviter tes br lures ne jamais toucher le compresseur d air pendant ou tout de suite apr s utilisation 7 Quand il n est pas utilis enrouler le fil lectrique autour du compresseur et stocker dans un endroit sec Faire attention ne pas endommager le fil lectrique 8 AVANT D UTILISER DE NETTOYER OU DE RETIRER TOUT ACCESSOIRE DEBRANCHER L APPAREIL ET REDUIRE LA PRESSION 9 CE SYSTEME PEUT PRODUIRE 9 5 kg cm 135 psi POUR EVITER TOUTE RUPTURE POUVANT ENTRAINER DES BLESSURES NE PAS UTILISER CETTE POMPE AVEC DES ACCESSOIRES PREVUS POUR UNE PRESSION INFERIEURE A9 5kg cm 135 psi Y COMPRIS MAIS NON LIMITE AUX PISTOLETS A PEINTURE TUYAUX ET RACCORDS DES TUYAUX Si des r parations ou un entretien en cours de garantie s av rent n cessaires addressez vous au service entretien agr le plus proche S il n y en a pas addressez vous lusine Des r parations ou un d montage non permis annuleront la garantie usine UTILISATION Id al comme source d air primaire ou secondaire pour pratiquement toute op ration Particuli rement pratique pour boutiques et garages ainsi que pour les usines o un usage r p t requiert un appareil de haute fiabilit 15 ENTRETIEN GENERAL ET SERVICE Lisez et comprenez l information dans le manuel de ce propri taire avant d op rer le compresseur CARACTERISTIOUES Ville EE 115V 60Hz RUSIA ed 10A R glage de la soupape de S ret 140
15. ites pas de soudures sur les r servoirs de ces compresseurs Des soudures sur les r servoirs de ces compresseurs air pourraient s rieusement affaiblir la r sistance des r servoirs et cr er des conditions tr s dangereuses N importe quelle soudure sur un r servoir annulera la garantie Si des travaux sous garantie ou des r parations sont n cessaires addressez vous un fournisseur r parateur autoris S il n y en a paspr s de chez vous contactez lusine Le d montage nonautoris de l appareil annulera la garantie 20 ELECTRIC COMPRESSOR TROUBLESHOOTING The following guide has been compiled to assist the consumer in identifying problems that may be encountered with electric compressors Please inspect for possible causes and contact an authorized service center when necessary SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Motor Won t Start No Power to Compressor Switch Lever in Off Position Faulty Start Relay Faulty Start Capacitor Check Circuit Breaker or Fuse Move Switch Lever to On Position 4 Compressor Won t Restart Check Valve Leaks Low Voltage to compressor Pressure Switch Hanging Up InspectCheck Valve Contact Service Center Connect Unit to Sufficient Voltage Source Inspect Pressure Switch Contact Service Center Low Air Output Compressor Won t Shut Off Leak At Fitting s Broken Valve Flapper Debris in Valves Faulty Head Gasket Faulty Val
16. kit 6 Gire la palanca on auto off en el conmutador de presi n a la posici n de apagado OFF 7 Sujete la manguera de aire al colector del compresor 8 Conecte el cable el ctrico a una salida puesta a tierra o a otra extensi n aprobada Vea la secci n Instrucciones para descarga a tierra Gire la palanca on auto off en el conmutador de presi n Gs a la posici n de encendido ON neum tica CABLES DE CONEXION Para evitar al motor disminuci n de tensi n y p rdida de potencia use una manguera adicional en lugar de un extension electrica Si hay necesidad de usar un extension electrica use nicamente un cable de conexi n de 3 hilos equipado con un enchufle de tierra de 3 gajos y un tomacorriente de tres ranuras que acepte el enchufe del compresor Aseg rese de que el cable de conexi n est en buen estado MEDIDAS MINIMAS PARA LOS CABLES DE CONEXION LONGITUD DEL CABLE 25PIES 50PIES 100PIES 150 PIES CALIBRE 12 12 10 8 NOTA El tama o del cable aurnenta conforme el calibre disminuye INSTRUCCIONES PARA LA CONEXION A TIERRA PELIGRO Una Conexi n a tierra incorrecta puede dar como resultado un choque electrico En caso de un corto circuito la conexi n a tierra disminuye el riesgo de un choque ya que provee un cable de escape para la corriente el ctrica El compresor de aire debe tener una conexi n a tierra El cable del compresor de aire viene listo con un cable con conexi n a tierre y un enchufe
17. ll start and stop automatically within the settings of the pressure switch The pressure switch is factory adjusted to start the compressor when the tank pressure drops below 100 PSIG and to stop when tank pressure reaches 122 PSIG To stop the compressor turn the lever clockwise to the OFF position Lever DO NOT STOP THE COMPRESSOR BY REMOVING THE ELECTRICAL PLUG The on off lever operates a valve which relieves pressure from the compressor If the lever is left on when the electric power is interrupted the compressor may have difficulty in starting under this pressure Operating Procedures 1 Make sure on off lever is in the off position WARNING Before using air tools or accessories check manufacturer s maximum pressure rating Maximum pressure rating must be above 122 PSIG 2 Attach air hose and accessory to compressor Remove orange pull plug first 3 Turn on off lever to the on position and allow tank pressure to build 4 When the motor stops it has reached cutout pressure and the unit is ready for use NOTE When using an accessory or air tool pressure in the storage tank decreases When it reaches a certain low level cut in pressure the motor will automatically restart and raise the pressure in the storage tank 5 To shut down compressor simply move on off lever to the off position 6 Allow compressor to cool 7 Drain storage tank see Storage Tank in Maintenance Section MAINTENANCE
18. macenamiento en la Secci n de Mantenimiento MANTENIMIENTO FILTRO DE AIRE Revise el filtro de aire antes de cada uso Limpie el filtro con agua y jab n seg n sea necessario Apriete el filtro para eliminar el exceso de humedad y deje que se seque antes Y de volverlo a instalar Si el filtro est obstruido o ON 3 da ado reempl celo ADVERTENCIA No opere el compresor de aire sin filtro de aire PRECAUCION Nunca limpie el filtro de aire con un liquido inflamable o un disolvente Vapores explosivos podrian acumularse en los tanques de aire y causar una explosi n dando como resultado lesiones serias o muerte 13 TANQUES DE ALMACENAMIENTO Los tanques de almacenamiento deben vaciarse despu s de cada uso o despu s de cada cuatro horas de operaci n para prevenir la creaci n de condensaci n y corrosi n dentro de los tanques Para vaciar los tanques lentamente y con mucho cuidado abra los accesorios de desague incline la unidad hacia el drenaje y deje que se desague y E tanques desag e NOTA Cuando est drenado los tanques fjese si salen trozos de metal corrido se esto ocurre debe contactar a su distribuidor para posible reemplazo del tanque ADVERTENCIA No suelde en los tanques de aire de estos compresores Soldar en los tanques de aire de estos compresores puede da ar seriamente la fortaleza del tanque y causar una situaci n extremadamente peligrosa Una soldadura
19. mettez le 7 levier marche arr t sur la position arr t 6 Laissez la compresseur se refroidir 7 Vindangez les r servoirs d accumulation voir r servoirs d accumulation a la section entretien 19 ENTRETIEN Filtre a air V rifiez le filtre air avant chaque utilisation de l appareil Nettoyez le filtre avec du savon et de l eau si n cessaire Fa Eliminez lexc s d humidit du filtre et laissez le s cher avant de le remettre en place Si le filtre est a bouch ou endommag remplacez le 0 A ATTENTION Ne jamais nettoyer le filtre a air avec un liquide ou un dissolvant inflammable Des gaz explosibles peuvent s accumuler dans les r servoirs et provoquer une explosion pouvant causer de tr s graves blessures ou m me la mort A ATTENTION Ne faites pas marcher le compresseur sans filtre a air R servoirs d accumulation Les r servoirs d accumulation doivent tre purg s apr s chaque utilisation ou toutes les quatre heures de marche pour emp cher une accumulation de condensation et la corrosion de l int rieur des r servoirs Pour purger les r servoirs ouvrez lentement et soigneusement les raccords de purge penchez l appareil du c t des raccords et laissez l eau sortir REMARQUE Quand vous purgez les r servoirs regardez s il se trouve des d bris particules de rouille Si oui contactez votre concessionnaire pour un ventuel remplacement des r servoirs ATTENTION Ne fa
20. mm THOMAS A Gardner Denver Product ULTRA 3524 WASHINGTON AVE SHEBOYGAN WI 53081 USA 1 800 558 7721 www thomasairpac com OWNER S MANUAL and OPERATING INSTRUCTIONS for Model T 617HDN Portable Perma Lube Heavy Duty WOBeL PISTON AIR COMPRESSOR D s Q Se y PRE J A WARNING Read and understand the information in this owner s manual before operating air compressor Part No 642485 Rev H 08 08 2006 Gardner Denver Thomas Inc Printed in U S A All Rights Reserved TABLE OF CONTENTS Page General DESCIIPUCM ari ae 1 Application A 1 Pe A 2 A 3 Operating Instructions 4 EN iii 6 Spanish Language Instructions 7 Exploded View amp Parts List 10 French Language Instructions 15 Compressor Troubleshooting 21 Limited Warranty sise 22 GENERAL DESCRIPTION The Airpac model T 617HDN is an electrically powered air compressor with a thermally protected motor mounted to a 2 gallon air storage tank Tank pressure is regulated by a combination of a pressure switch and a safety valve The pressure switch will turn the compressor on when tank pressure drops below 100 PSIG and turn the compressor off when tank pressure reaches 122 PSIG The safety valve prevents tank pressure from exceeding 140 PSIG SPECIFICATIONS e Ce 115V 60Hz FUSE RequirementS 2 c0ccccentsccccecsansc
21. na palanca ON AUTO OFF localizada en un lado del interruptor de presion Gire la palanca a la posicion ON AUTO y el compresor arrancara y parara automatica mente dentro del rango de presion del interruptor El interruptor esta ajustado de fabrica para arrancar el compresor a presiones inferiores de 110 PSI y para cuando la presion alcanza 135 PSI en el tanque Para parar el compresor gire la palanca a la posicion OFF NO PARE EL COMPRESOR REMOVIENDO LA CLAVIJA DEL TOMACORRIENTE La palanca ON OFF opera una valvula la cual alivia la presion del compresor Si la palanca se deja en ON cuando la corriente electrica es interrumpida entoces el compresor podria tener dificultad para arrancar 12 PROCEDIMIENTO PARA EL FUNCIONAMIENTO 1 Asegurese de que la unidad esta apagada PRECAUCION Antes de usar herramientas o accesorios neumaticos revise la capacidad de presi n maxima del fabricante Le capacidad de presi n m xima debe estar sobr e 135 PSIG 2 Una la manguera neum tica y el accesorio 3 Ponga la palanca de conectar y desconectar en posici n on y deje que la presi n del tanque aumente 4 Cuando el motor se para ha alcanzado presi n de desconexi n y la unidad est lista para usarse 5 Para apagar el compresor simplemente mueva la palanca de conectar y desconectar a la posici n off 6 Deje enfriar el compresor 7 Drene los tanques de almacenamiento ve se Tanques de Al
22. presseur quand la pression du r servoir tombe au dessous de 110 PSIG et de cesser quand la pression de r servoir atteind jusqu a 135 PSIG Pour fermer le compresseur tourner le levier dans sens des aguilles d une montre a la position verticale NE FERMER JAMAIS LE COMPRESSEUR PAR ENLEVEMENT LE TAMPON ELECTRIQUE Le levier de en action ferme fonctionne la soupape qui soulage la pression de compresseur Si le levier est laiss en action quand la puissance lectrique est interrompue le compresseur peut avoir la difficult de d marrer avec cette pression MODE D EMPLOI 1 Assurez vous que le levier marche arret se trouve sur la position position d arr t ATTENTION Avant de vous servir d outils ou d accessoires air comprim v rifiez le taux maximum de pression recommand par le fabricant Ce taux doit tre sup rieur 122 PSIG 2 Attachez le tuyau el l accessoire 3 Mettez le levier sur la position marche et laissez la pression monter dans le r servoir 4 Quand le moteur s arr te il a atteint son niveau de pression d arr t et l appareil est pr t fonctionner REMARQUE Quand vous utilisez un accessoire ou un outil air comprim la pression dans les r servoirs d accumulation d croit Quand celle ci atteint un certain niveau minimum perte de pression le moteur red marrera aussit t automatiquement et CARRE P fera monter la pression dans les r servoirs 5 Pour arr ter le compresseur
23. rate air compressor in a clean dry and well ventilated area The air filter must be kept clear of obstructions which could reduce air flow to the compressor The air compressor should be located at least 12 away from walls or other obstructions that could interfere with the flow of air 1 Remove the air compressor from the carton and place it on its side 2 Install the 4 rubber feet with the screws included in the accessory kit as shown tank drain 3 Close the tank drain valve valve L N attach feet a De 2 each side 4 Remove 2 head screws and install handle with hardware included in accessory kit 5 Turn on auto off lever on the pressure switch to the OFF position 6 Attach air hose to the compressor manifold 7 Plug the power cord into a grounded outlet or approved extension cord See Grounding Instruction section Turn the on auto off lever on the pressure switch to the ON position Extension Cords To avoid voltage drop and power loss to motor use additional hose instead of an extension cord If an extension cord must be used use only a 3 wire extension cord equipped with a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the compressor Be sure to use an extension cord heavy enough to carry the current your product will draw An undersized cord will cause a drop in line voltage resulting in loss of power and overheating Make sure the extension cord is in good condition
24. ressor Welding on the air compressor tank can severely impair tank strength and cause an extremely hazardous condition Welding on the tank in any manner will void the warranty If warranty service or repairs are needed contact your nearest authorized servicing dealer If one does not exist contact the factory Unauthorized teardown of the unit will void the factory warranty REGLAS PARA UNA OPERACION SEGURA A PRECAUCION Antes de operar el compressor de aire lea este manual del propietario y asegurese de comprender la informaci n aqui contenida 1 El compresor debe ubicarse en una zona seca timpia y bien ventilada 2 Antes del uso inspeccione la manguera el tap n y elcable para asegurarse de que est n en buenas condiciones En caso contrario no use el compresor Las unidades da adas nunca deben operarse Para la obtenci n de piezas de reemplazo consulte con su centro de servicio m s pr ximo 3 El ajuste de la v lvula de alivio de seguridad ha sido fijado en la f brica No lo altere Los ajustes de esta v lvula peudan provocar lesiones graves 4 Esta unidad no requiere lubricaci n Puesto que el compresor no requiere ser aceitado la aplicaci n de aceite a cualquier componente podr a resultar en el suministro de aire contaminado al equipo correspondiente 5 El flujo de aire comprimido no debe dirigirse a ninguna persona porque puede provocar lesiones graves No permita que se acerquen los ni os UTILICE PROTECTORE
25. u d air au distributeur du compresseur 7 Raccorder le cable d alimentation dans une prise de courant a contact de mise a la terre ou une rallonge agr e Voir la partie des proc dures de mise a a terre Activer placer en mode automatique ou d sactiver le levier sur le pressostat en position ON Relier le tuyau d air J 16 Rallonge Electrique Pour viter des chutes de voltage et des pertes de puissance au moteur utilisez des tuyaux suppl mentaires au lieu d une rallonge lectrique Si une rallonge doit tre utilis e n utilisez qu une rallonge lectrique a trois fils avec une fiche a troisbroches prise de terre et une prise a trois trous pour recevoir la fiche qui se trouve sur le compresseur d air Assurez vous que la rallonge est en bon tat CALIBRE MINIMUM DES RALLONGES ELECTRIQUES DE RALLONGE 25 PIEDS 50 PIEDS 100 PIEDS 150 PIEDS CALIBRE 12 12 10 8 REMARQUE La grosseur du fil augmente lorsque ie chiffre du cali bre diminue Instructions de mise la terre DANGER Une mauvaise mise la terre peut causer des lectrocutions En cas de court circuit la mise la terre r duit le risque d lectrocution en permettant au courrant de s chapper Le compresseur d air doit tre mis la terre Le fil lectrique du compresseur d air est quip d un fil de terre et d une fiche de terre appropries La fiche doit tre utilis e avec une prise install e et mise la terre selon
26. ve Plate Gasket Worn Piston Cup Leak At Fitting s Broken Valve Flapper Debris in Valves Faulty Head Gasket Faulty Valve Plate Gasket Worn Piston Cup Relief Valve Leaking Inspect Fittings If Loose or Damaged Contact Service Center OOOO Inspect Fittings If Loose or Damaged Contact Service Center OO OOOO Water in Air Lines or Tools Low Pressure to Tools Tank Not Drained Regularly Damaged Gauge on Regulator Drain Air from Tank s through Drain Valves Ensure Air Lines are Free of Moisture Inspect Gauge Contact Service Center Regulator Not Adjusted Properly Adjust Regulator to Faulty Regulator Required Pressure Inspect Regulator Contact Service Center ATTENTION The automatic pressure switch prevents this unit from running if the tank pressure exceeds 100PSI If the compressor will not start drain the pressure from the tank These procedures require special fixtures tools or asssembly techniques available only through a Service Center For service contact the dealer from whom you purchased the compressor To order parts visit our website www thomasairpac com or call our Customer Service Center at 1 800 848 7735 21 Limited Warranty The Gardner Denver Thomas Inc Compressor is warranted to you the original purchaser for a period of one year from date of original purchase to be free from defects in material and workmanship If during the specified warranty period you belie
27. ve the purchased product or any part thereof has such a defect you must return the product or part during such period with proof of purchase and at your cost to the nearest authorized service center consult the list of service centers enclosed with the product for repair or replacement of the defective part If you do not know the location of the nearest service center contact Gardner Denver Thomas Inc at the address below for instructions If the product or part is found to have been defective in material or workmanship it will be repaired or replaced as deemed necessary by the repair center free of charge and returned to the purchaser at the purchaser s cost If the repair work must be done at the Gardner Denver Thomas Inc factory transportation costs of the product or part to and from the factory must be paid by the purchaser The warranty shall not apply to any compressor which in Thomas judgement has been subject to misuse negligence or accident or which has been operated from an inadequate power supply All wearing and consumable parts are excluded under the terms of this warranty This warranty shall not apply to compressors that require oil for operation which have been operated with oil levels below that specified by Gardner Denver Thomas Inc THE MANUFACTURER LIMITS THE DURATION OF THE IMPLIED WARRANTY OF MERCHANTABILITY TO THE LIMITED WARRANTY PERIOD SET FORTH ABOVE AND OTHERWISE DISCLAIMS ALL IMPLIED WARRANTIES WIT
28. y 1 666459 S Conn Rod Ass y Service 1 2 625088 Eccentric Set Screw 1 as 624396 Piston Cup 1 4 625180 Screw Cup Retainer 1 5 626397 Piston Cup Retainer 1 6 670031 Cylinder Sleeve 1 7_ 610869 500 Head 1 8 623143 O Ring Head Gasket 1 9 625175 Screw Head 4 10 621647 Valve Backer 1 hb 617562 Wave Keeper Strip 2 12 621485 Valve Flapper Int amp Exh 2 13 621632 540 Valve Plate 1 14 625094 Screw Valve Plate 2 15 623071 O ring Valve Plate 1 16 638281 Fan Black 1 Item Part No Description Qty 17 647076 Fan Guard 1 18 603178 Capacitor Bracket 1 19 625434 Screw 8 16 x 3 8 Torx 2 20 603025 Capacitor 8mfd 450V 1 21 603167 Capacitor Cover 1 22 625449 Screw 8 32 x 3 8 Torx 2 23 633160 Strain Relief Bushing 1 24 660710 Filter Body 1 25 641034 Filter Foam 1 26 660767 Filter Body Cap 1 27 629081 Handle 1 28 625379 Screw Handle 2 29 626014 Washer Handle 2 10 TANK PARTS LIST 618149 Exhaust Tube 1 615826 UnloaderTube 1 617677 Drain Cock Assembly 1 624654 Bumper sds 1 Wem Part No Description Qty 40 624517 Connector Head 41 625206 Screw Cprsr Mounting 42 626563 Washer Cprsr Mounting 43 626509 Lock Washer Cprsr Mtng 44 626766 Nut Compression 45 625406 Screw Bumper 46 633660 Cord 47 633957 Safety Valve 48 638262 Gauge Pressure 49 638322 Check Valve
29. y grounded Do not modify the plug that has been provided If it does not fit the available outlet the correct grounded outlet must be installed by a qualified electrician OPERATION Safety Valve The safety valve is designed to prevent pressure in the storage tank from exceeding 140 PSIG A WARNING Do not tamper with or attempt to eliminate the safety valve Thermal Overload Protector The compressor motor is equipped with a thermal overload protector If the motor should overheat the overload protector will shut the motor off If this occurs turn the on off lever to the off position and allow motor to cool for approximately 5 minutes NOTE Tank pressure must be below 100 PSIG for the compressor to start Restart the compressor by moving on off lever to the on position If compressor fails to start check for blown fuses the compressor may require more time to cool If the overload protector shuts down the motor frequently it could be due to low voltage Common signs of low voltage are 1 Motor does not get up to power or speed 2 Fuses or circuit breaker activate when starting compressor 3 Lights dim or remain dim when compressor is started 4 Other motor operated appliances fail to operate property 5 Too many motor operated appliances on same circuit Pressure Switch The compressor is operated by an on auto off lever on the side of the pressure switch By turning the lever to the AUTO position the compressor wi
Download Pdf Manuals
Related Search
Related Contents
User Manual & Troubleshooting Guide - HMVC Consulting LG GR500R Quick Start Guide Operating Instructions Service Manual hatches aceite italika Manual de Utilização - Hanna Instruments Portugal 2 - Onkyo DSmobile 600 Guida dell`utente ACTi IVS Server 1 - ACTi Corporation SUCTION CANVAS Model: TCB-CA281BE, CA501BE Copyright © All rights reserved.