Home

CALIBREX 521

image

Contents

1. 22 25 28 30 34 36 38 40 45 mm PERFORMANCE DATA AND ORDERING INFORMATION Volume Range Increment mL mL mL 28 Accuracy Precision 314 0500P Pyrex glass reservoir 32 mm 500 mL with side neck Amber glass reservoir 32 45 mm 0100 0250 0500 1000 2500 mL PE reservoir 25 45 mm 250 0500 1000 2500 mL Threaded adaptater PTFE 36 38 40 45 mm Amber glass reservoir with PE coating 32 45 mm 0500 1000 2500 mL Tapered adapter PP 320 SB050 Stand for one dispenser Spare feed tube 300 mm 7 5 mm 18 8 24 29 2 45 mm up to 50 mL model PTFE 20 mL model NST xx Tapered adapter PTFE 320 BC050 Stand for remote liquid intake Spare feed tube 300 mm 10 mm 18 8 24 29 2 mm 20 and 50 mL models PTFE 50 mL model 60 cm delivery extension tubing 320 BC100 Stand for remote liquid intake Spare feed tube 375 mm 10 mm PTFE for 20 mL model 100 mL model PTFE 100 mL model SOCOREX ISBA S A CH CHAMP COLOMB7 P O BOX CH 1024ECUBLENS LAUSANNE SWITZERLAND SPARE PARTS ERSATZTEILE LISTE DE PIECES Plunger cap Kolben Deckel Capuchon Selector assembly Selektor Aggregat Assemblage selecteur Sleeve Mantel Douille Glass barrel Glaskolben Cylindre de verre Body Korper Embase Intake valve Saugventil Soupape d aspiration Guide bar Fuhrungsstange R glette Intake valve ball Kugel Saugventil Bille soupape d aspirat
2. ch ant utiliser une potence si le flacon n offre pas une base assez stable fig 1 voir accessoires p 4 DOSING INSTRUCTION Volume setting The selected volume is shown in the windows of the guide bar No 7 fig 2 Rotate selector No 2 until desired main volume appears It automatically clicks in on the right position While holding selec tor rotate vernier No 16 until desired intermediary volume appears in the windows Correct position is achieved when both numbers are on one line Priming To prime the unit activate the plunger fully at least once and follow with several short strokes up to lower stop to eliminate air bubbles in the delivery jet Liquid should be collected in a clean vessel and may be recycled Dispensing Remove tip cap No 14 before dosing Raising the plunger fills the dispenser barrel Depress to dis pense liquid Best results are obtained by moving the plunger gently and regularly between the upper and the lower stop Liquid density or viscosity may change dosing speed and instrument performance Never apply force when working End of dosing After use place tip cap No 14 on delivery jet to pre vent fluid from leaking back and valves to dry out Rinse instrument carefully before storing if liquid likely to solidify MAINTENANCE Regular maintenance of the Calibrex dispenser 521 will substantially contribute to its optimal working and long life span Opening Make sure the dispenser barrel con
3. den Modellen 50 und 100 ml ist zuerst der Si cherheitsstecker zu entfernen und die Ausstosska n le Nr 13 zu befestigen Vor der Inbetriebnahme Ansaugschlauch Nr 9 in Saugventil Nr 6 ohne Ge waltsanwendung befestigen Wenn n tig Ansaug schlauch auf die richtige L nge zuschneiden Den auf den Flaschenhals passenden Adapter w hlen und auf die Flasche aufschrauben Flaschenhalte rung verwenden falls der Beh lter nicht gen gend Stabilit t gew hrt Abb 1 siehe Zubeh re S 4 CONSIGNES DE S CURIT e Avant utilisation lire avec soin le mode d emploi Respecter les consignes du fabri cant e Conna tre les r gles de s curit sur l emploi de r actifs dangereux et s y r f rer au besoin e Contr ler avant chaque usage le parfait tat de fonctionnement et d tanch it de l ins trument e Bien purger et rincer un doseur avant de le d monter et de le stocker e Ne jamais pointer le bec verseur en direction d une personne lors du dosage e En cas de pieces bloqu es ne jamais forcer sur l assemblage piston cylindre e Retirer le capuchon de protection sur le bec verseur avant dosage e Temp rature d utilisation maximale lt 50 C e Transporter ou d placer le dispenser en tenant toujours fermement la bouteille e L instrument ne doit tre utilis que pour les fins d finies ci dessous DESCRIPTION Construit avec des mat riaux sp cialement s lec tionn s le dispenser Calibrex 521 a volume varia b
4. factory calibrated and does not require any particular calibration Should the per formance of the instrument during routine control no longer correspond to the manufacturer s speci fications or if conditions of use liquid density tem perature etc require recalibration this can be easily performed gravimetrically using an analyti cal balance A control and calibration of the dispenser is also recommended when changing following parts Plunger cap No 1 selector No 2 plunger and barrel assembly No 4 guide bar No 7 or vernier ring No 16 Calibration screw a located under plunger cap No 1 corresponds to the lower stop of plunger travel fig 3 Shorten the lower stop position cali bration screw deeper in cap No 1 will increase the volume and vice and versa Unscrew calibration fixing screw b before per forming a calibration and check resulting volume smooth dispensing at constant speed after each adjustment Tighten fixing screw again after cali bration Sterilization Instrument has been designed for repeated sterili sation in the autoclave at 121 C 20 minutes fully assembled Do not sterilize an instrument which has not been primed and rinced Place instrument horizontally in the autoclave avoiding any direct contact with metal Allow instrument to dry and cool down to room temperature before use Make sure plunger and all connections are securely tight Repeated autoclaving may affect material colours Corre
5. obtaining return au thorization Decontaminate instrument prior to returning it Bei Verkleben des Kolbens bzw der Ventile Gerat auseinanderschrauben und die Teile in eine Labor spulmittell6sung eintauchen Danach reichlich spu len Funktionen berpr fen Nie Gewalt an blockierten Kolben anwenden der Glaszylinder k nnte sonst zerbrechen Blockierte Teile ber Nacht in Detergenzien einwirken lassen Von Zeit zu Zeit Sauberkeit des Saug Nr 6 und Dosier ventils Nr 10 kontrollieren Ein Ultraschall Bad erlaubt an schmutzigen Ventilen Partikeln zu ent fernen Kalibrierung Das im Werk kalibrierte Ger t ben tigt im Normal fall keine neue Eichung Falls die bei einer Kontrol le gemessenen Werte nicht mehr mit den vom Hersteller angegebenen Daten bereinstimmen oder falls die Ben tzungsbedingungen Fl ssig keitsdichte Temperatur usw eine neue Kalibrie rung verlangen kann diese leicht mit der gravimetrischen Methode durchgef hrt werden Kontrolle und Kalibrierung des Dispensers sind beim Auswechseln der folgenden Ersatzteile emp fohlen Kolbendeckel Nr 1 Selektor Nr 2 Kolben und Zylinderaggregat Nr 4 F hrungsstange Nr 7 oder Vernier Ring Nr 16 Die Kalibrierschraube a unter dem Kolbendeckel Nr 1 entspricht dem unteren Stop der Kolbenstrek ke Abb 3 Zur Vergr sserung des Volumens Kol benstr cke verl ngern Kalibrierschraube im Uhrzeigersinn drehen und umgekehrt zur Vermin derung des Volum
6. tergente jusqu s paration ais e des pi ces V rifier de temps autre la propret des soupapes N 6 et N 10 Le bain ul trason aide l limination de r sidus sur une sou pape bloqu e Etalonnage L instrument est calibr d usine et ne n cessite en principe pas d talonnage Si lors du contr le de l instrument les valeurs ne sont plus dans les tol rances du fabricant ou si les conditions d utilisa tion densit du liquide temp rature etc n cessitent un re talonnage celui ci sera ais ment effectu par gravim trie sur une balance de pr ci sion Un contr le et une calibration du dispenser sont re command s lors du changement des pi ces sui vantes Capuchon N 1 selecteur N 2 assemblage piston et cylindre N 4 r glette N 7 ou bague N 16 La vis d talonnage a situ e sous le capuchon N 1 correspond la but e du piston fig 3 Rac courcir cette but e visser dans le sens des aiguilles d une montre augmente le volume et vice versa D visser la vis de blocage b avant d effectuer une calibration et contr ler le volume r siduel course douce et r guli re du piston apr s chaque ajuste ment de la vis d talonnage Resserrer la vis de blo cage une fois l instrument calibr St rilisation L instrument est con u pour tre st rilis l auto clave 121 C 20 minutes sans d montage Ne pas autoclaver un instrument non purg ni correc tement rinc Pl
7. tout blocage ENTRETIEN Seul un entretien r gulier du dispenser Calibrex 521 assure son bon fonctionnement et contribue sa long vit D montage S assurer d abord en pressant sur le piston que le dispenser ne contient plus de liquide D visser le dispenser de la bouteille et le purger au besoin Re tirer le tuyau d aspiration N 9 D visser la but e N 12 et tirer le capuchon N 1 pour sortir le piston du cylindre D visser la bague N 19 et tirer l embase N 5 Ceci permet d acc der au cylindre N 4 D visser le bec N 13 pour acc der la soupape N 10 Apr s remontage s assurer que le dispenser fonc tionne correctement par quelques mouvements d aspiration et de dosage Les pi ces d fectueuses doivent tre remplac es par des pi ces originales uniquement Nettoyage Rincer r guli rement le circuit emprunt par le li quide par ex lorsque le flacon est vide ou avant de doser un nouveau liquide When plunger is dragging or sticking disassemble the instrument Soak dirty parts in a mild laborato ry detergent Rinse carefully then check correct function after assembling To separate a frozen plunger never use force the glass barrel could break Leave frozen plunger assembly soaking in an appropriate detergent overnight Check regularly both aspiration valve No 6 and dis pensing valve No 10 Ultra sonic bath may help to remove residue on dirty valves Calibration The instrument is
8. CALIBRBEN 521 BOTTLE TOP DISPENSER FLASCHEN DISPENSER DISPENSER POUR FLACONS OPERATING INSTRUCTIONS BETRIEBSANWEISUNG MODE D EMPLOI SAFETY PRECAUTIONS e Read operating instructions carefully observe manufacturer s general recommen dations Refer and follow regulations about handling of potentially hazardous reagents e Before each dosing operation control per fect working and tightness condition of the instrument Prime and rinse dispenser carefully when left unused for a while or before disassembling Delivery jet should never point towards a person while dosing Blocked parts should not be separated by applying force on plunger barrel assembly Remove tip cap from delivery jet before dos ing e Maximal temperature of use lt 50 C e Hold reagent reservoir firmly while carrying dispenser e This instrument should be used only for its intended purpose DESCRIPTION Built with carefully selected materials the adjusta ble volume Calibrex dispenser 521 is autoclavable fully assembled It allows a safe repeated dosing of a large number of reagents with outstanding accu racy and precision Three models are available to cover a range from 2 to 100 mL 2 20 mL 10 50 mL 10 100 mL Three other models of Calibrex 520 cover smaller volume ranging from 0 25 to 10 mL The instrument fits directly most laboratory bottles with standard 32 mm screw neck Threaded adapters for 38 40 45 mm are supplied Addi tional
9. ION DE DOSAGE R glage du volume Le volume s lectionn apparait dans la fen tre de la r glette N 7 fig 2 Tourner le s lecteur N 2 jusqu a ce que le chiffre choisi apparaisse dans la fen tre La bonne position est signal e par un encli quetage perceptible Sans lacher le s lecteur tour ner la bague de r glage N 16 jusqu a ce que le chiffre du volume interm diaire voulu apparaisse dans la fen tre Le r glage est correct lorsque les chiffres y sont parfaitement align s Purge Lors de la mise en route effectuer les mouvements d aspiration et d expulsion sur toute la course du piston r p ter l op ration sur une petite course afin d liminer toutes bulles d air la sortie du bec verseur Le liquide r cup r dans un r cipient pro pre peut tre r utilis Distribution Retirer le capuchon N 14 avant dosage Tirer le piston vers le haut remplit le cylindre le pousser vers le bas distribue la dose Des performances op timales s obtiennent en actionnant le piston de ma ni re r guli re souple et sans coup d une but e l autre La densit et ou la viscosit d un liquide peuvent modifier la vitesse d aspiration ou de do sage Ne jamais employer la force lors du dosage Fin de travail Replacer le capuchon N 14 sur le bec verseur afin d emp cher tout retrait de liquide et un dess che ment ventuel des soupapes L instrument doit tre purg et rinc avant rangement pour viter
10. acer l instrument plat dans l auto clave en vitant tout contact direct avec des pi ces m talliques L instrument doit tre sec et compl te ment refroidi avant son utilisation Apr s st rilisa tion v rifier que le piston et tous les raccords sont bien serr s Un changement de couleur des mat riaux peut appara tre long terme L utilisateur est responsable des bonnes conditions d autoclavage ainsi que de la st rilit r sultante Le Calibrex 521 020 peut galement tre autoclave avec sa ral longe de distribution en PTFE N cat 1 524 Mat riaux Toutes les parties en contact avec le liquide sont chimiquement inertes e Corps de soupape ETFE et c ramique e Billes de soupape rubis synth tique ou c rami que e Siege de soupape verre e Ressort de soupape platine iridium e Cylindre verre borosilicate neutre e Piston verre avec solide couche PFA e Embase ETFE e Tuyau d aspiration et bec verseur PTFE ETFE Attention les vapeurs d acides forts concentr s peuvent la longue endommager l instrument et r duire sa dur e de vie Eviter de laisser en perma nence un dispenser sur une bouteille contenant un acide fort concentr le rincer apr s emploi Les m mes recommandations permettent d viter des pertes de solvants volatils long terme Les d g ts d s a l emploi de r actifs non compati bles ne sont pas couverts par la garantie En cas de doute l utilisateur doit s assurer de la com
11. ct autoclaving and resulting sterility are the responsibility of the user Calibrex 521 020 may be autoclaved when fitted with the PTFE extension tubing cat No 1 524 Materials All parts in contact with the liquid are chemically in ert e Valve body ETFE ceramic e Valve balls synthetic ruby or ceramic e Valve seat glass e Valve spring platinum iridium e Barrel neutral borosilicate glass e Plunger glass with sturdy PFA coating e Body ETFE e Feed tube and delivery jet PTFE ETFE Warning Vapours of concentrated strong acids may damage your instrument after some time and reduce its life span It is recommended not to leave the dispenser permanently on a bottle containing concentrated strong acids and to rinse it after use To prevent long term loss of product by evapora tion the same recommandation is valid when us ing volatile solvants Damages due to incompatible reagents are not warranty covered In case of doubt check for chem ical compatibility or refer to manufacturer before use WARRANTY The 521 Calibrex dispenser is guaranteed for a pe riod of one year against any factory or material de fect Glass breakage or cases due to non respect of manufacturer s and safety instructions are exclud ed from the warranty Repairs and changing parts do not extend the warranty period Should regular maintenance not eliminate a detect ed defect return the instrument to the dealer from whom it was purchased after
12. diameters and adapters for tapered necks are available upon request The Solid Calibration System consisting in one cam with pre calibrated steps provides for digital volume entry and numerical display An additional fine tuning ring allows quick volume setting The dispenser Calibrex 521 is easy to operate maintain and calibrate The Calibrex 521 fixed volume models have the same caracteristics but volume is locked on a se lected position OPERATION Calibrex 521 20 mL is supplied fully assembled On 50 and 100 mL models first remove shipping plug and attach delivery jet assembly No 13 Introduce without applying force feed tube No 9 in the aspira tion valve No 6 Cut feed tube to the desired length if necessary Select an adapter apropriate to the bottle and in stall the instrument Use a stand to hold the unit if original reagent bottle does not provide for suffi cient base stability Fig 1 see accessories on page 4 A SOCOREX S CALIBRATION 121 C SICHERHEITSANWEISUNGEN e Vor Gebrauch Betriebsanweisung sorgfaltig lesen Sicherheitsanweisungen vom Herstel ler beachten e Sicherheitsvorschriften Uber die Anwendung von gefahrlichen Stoffen beachten e Vor jedem Gebrauch kontrollieren ob das Gerat dicht und in perfektem Arbeitszustand ist e Vor Demontage oder langerer Lagerung Gerat entluften und sorgfaltig spulen e Ausstosskanule wahrend dem Dosieren nie gegen andere Personen richten e Blockiert
13. e Teile niemals durch Gewaltsan wendung an Kolben Zylinder oder Geh use trennen e Verschlusskappe vor Dosieren entfernen e Maximale Anwendungstemperatur lt 50 C e Bei Transport Flasche immer gut festhalten e Das Instrument nur f r dazu bestimmte Zwecke ben tzen BESCHREIBUNG Der aus ausgew hlten Materialien hergestellte Fla schen Dispenser Calibrex 521 bietet f r Seriendo sierungen von vielen handels blichen Reagenzien eine hervorragende Leistung Drei Gr ssen decken den Bereich von 2 bis 100 ml 2 20 ml 10 50 ml 10 100 ml Drei andere Gr ssen des Modells 520 erweitern den Dosierbereich in kleineren Bereichen von 0 25 bis 10 ml Ein Standard Gewinde von 32 mm erlaubt das Aufschrauben des Ger tes auf alle g ngigen La bor Reagenzbeh lter Drei Adapter 38 40 und 45 mm sind beigelegt Weitere Adapter auch f r Normalschlieff Flaschen sind als Zubeh r erh lt lich Das einmalige Solid Calibration System sorgt f r die simultane Digital Eingabe und numerische Vo lumenanzeige Der Dispenser verf gt ber einen zus tzlichen Ring f r intermedi re Volumeneinstel lung Das Ger t bietet nicht nur eine angenehme Hand habung sondern auch eine einfache Wartung und Kalibrierung Calibrex Fixvolumen Modelle verf gen ber die selben Eigenschaften Einzig die Lehre wurde defi nitiv auf ein bestimmtes Volumen fixiert INBETRIEBNAHME Der Calibrex 521 020 wird betriebsbereit geliefert Bei
14. ens Vor jeder Kalibrierung Blockierschraube b ab schrauben Danach jede Einstellung resultierende Volumen berpr fen sanfte Dosierung bei gleich m ssigen Bewegungen Blockierschraube nach beendigter Kalibrierung wieder verschrauben Sterilisation Instrument ist bei 121 C 20 Minuten im Autoklav komplett zusammengesetzt sterilisierbar Ger t zu erst sorgf ltig reinigen und sp len horizontal in den Autoklav legen direkten Kontakt mit Metall vermeiden Vor Gebrauch pr fen dass Dispenser trocken und vollst ndig abgek hlt ist Nach jedem Autoklavieren pr fen dass alle Elemente fest ver schraubt sind Eine Ver nderung der Materialfarbe kann nach wiederholtem Autoklavieren auftreten Korrektes Autoklavieren und daraus resultierende Sterilit t stehen unter der Verantwortung des An wenders Calibrex 521 020 kann ebenfalls mit mon tiertem Verlangerungsschlauch Kat Nr 1 524 autoklaviert werden Materialien Alle mit Fl ssigkeit in Ber hrung kommende Teile sind aus chemisch best ndigen Materialien e Ventilk rper ETFE Keramik e Ventilkugeln synthetische Rubin Keramik e Ventilsitz Glass e Ventilfeder Platin Iridium e Zylinder Borosilikat Glas e Kolben Glas mit bestehende PFA Beschichtung e K rper ETFE e Ansaugschlauch Ausstosskan le PTFE ETFE Vorsicht D mpfe von konzentrierten starken Sau ren k nnen langfristig Ihr Ger t besch digen und dessen Lebensdauer verk rzen Es wird em
15. h Hochzie hen des Kolbens wird der Zylinder gefullt Beim Niederdrucken wird der Inhalt ausgestossen Lang same regelmassige Bewegungen zwischen oberen und unteren Anschlag ergeben die besten Resulta te Dichte oder Viskosit t der Fl ssigkeit k nnen die Dosiergeschwindigkeit sowie die Leistungsdaten verandern Niemals mit Gewalt hochziehen oder niederdrucken Dosiervorgang beenden Um einen Rucklauf der Flussigkeit sowie ein Aus trocknen der Ventile zu verhindern Verschlusskap pe Nr 14 auf die Ausstosskanule aufstecken Leerpumpen und Sp len des Dispensers sind un bedingt erforderlich um eine Blockierung des Ge rates zu vermeiden WARTUNG Eine sorgfaltige Wartung tragt zu einer reibungslo sen Arbeit mit dem Dispenser Calibrex 521 sowie seiner Langlebigkeit bei Gerat auseinandernehmen Gerat zuerst spulen und leerpumpen Dispenser von der Flasche entfernen Saugschlauch Nr 9 her ausziehen Danach Schraube Nr 12 abschrauben und Deckel Nr 1 herausziehen Der Kolben trennt sich vom Zy linder Ausstosskanule Nr 13 abschrauben Mutter Nr 19 abschrauben und Korper Nr 5 entfernen um an den Zylinder Nr 4 zu kommen Nach dem Zusammensetzen kontrollieren dass das Ger t einwandfrei arbeitet Beschadigte Teile sollten ersetzt werden Nur Original Ersatzteile be nutzen Reinigung Wann immer die Reagenzflasche leer ist oder vor dem Dosieren einer anderen Flussigkeit sollte das Gerat gereinigt werden OPERAT
16. ion Feed tube Saugschlauch Tuyau d aspiration Outlet valve assembly Delivery jet connector Clik stop assembly Guide ring fixing screw Guide bar fixing plate Guide bar fixing screw Vernier finger Guide ring Calibration fixing screw Calibration screw Distance ring NNNNNNN sech ech sech ech ch ech ch em ch WW OO O w OO O NNNNNNN a sech ech ch ech ch ch ch Ausgangsventil Mutter Ausstosskanule Clik stop Aggregat Fuhrungsring Schraube Fuhrungsstange Platte Fuhrungsstange Schraube Vernier Finger Guide Ring Blockierschraube Kalibrierschraube Distanzring TEL 41 0 21 651 6000 FAX 41 0 21 651 6001 socorex socorex com www socorex com Soupape de distribution Raccord de bec Stop screw Blockierschraube But e Delivery jet Ausstosskanule Bec verseur Tip cap Deckel Capuchon du bec Vernier ring Vernier Ring Bague de r glage Nut Mutter Ecrou T union T St ck Raccord en T Ring Ring Bague Assemblage cliquet Vis bague r glette Plaquette Vis r glette Vernier index Bague r glette Vis de blocage Vis de calibration Bague de calage NNNNNNN a ech sech ech ch ech ch ch ch w w O Q M SYSTEM ISO 9001 13485 CERTIFIED 1521 P C 106
17. le est enti rement autoclavable Il permet le dosage en s rie d un grand nombre de r actifs dans les meilleures conditions de justesse et de precision Trois mod les couvrant les plages de 2 a 100 ml 2 20 ml 10 50 ml 10 100 ml sont dis ponibles Trois autres grandeurs du mod le Cali brex 520 permettent le dosage dans de plus petits volumes 0 25 10 ml L instrument est con u pour tre viss directement sur les flacons de laboratoire grace a son filetage standard de 32 mm et a ses 3 raccords 38 40 45 mm D autres diam tres ainsi que des raccords pour flacons a col rod sont disponibles en acces soires Le syst me de Solid Calibration consiste en une came avec but es pr talonn es assurant l entr e digitale du volume et son affichage num rique Une molette suppl mentaire permet le r glage des volumes interm diaires Les mod les Calibrex 521 a volume fixe poss dent les m mes caract ristiques Seule la came a t bloqu e de mani re permanente sur une position choisie MISE EN SERVICE Le dispenser Calibrex 521 de 20 ml est livr pr t a l emploi Sur les mod les de 50 et 100 ml retirer au pr alable le bouchon de s curit et visser le bec verseur N 13 Introduire sans forcer le tuyau d as piration N 9 dans la soupape N 6 Au besoin l ajuster a la longueur voulue S lectionner un raccord appropri au diam tre du col de la bouteille puis visser l instrument Le cas
18. patibilit chimique ou se r f rer au fabricant avant emploi GARANTIE Le doseur Calibrex 521 est garanti un an contre tout d faut de mati re ou de fabrication Le bris de verre de m me que le non respect des instructions du fa bricant et des consignes de s curit ne sont pas couverts par cette garantie Les r parations et changements de pi ces ne prolongent pas la dur e de garantie Si l instrument pr sente un d faut qui n a pas pu tre limin par l entretien courant le retourner pour r paration apr s obtention de l accord du re vendeur Rincer et d contaminer l instrument avant de le retourner TECHNISCHE DATEN UND DONNEES TECHNIQUES ET BESTELLINFORMATIONEN CATALOGUE Err Rel CN Cat No Cat No Adj volume Fixed volume Values refer to the maximum volume obtained by a regular and smooth plunger When ordering specify desired fixed volume movement ith Acqua bidest at constant temperature 0 5 C comprised within instrument range between 20 and 25 C in accordance with ISO 8655 Max cinematic Example of liquids Test conditions for viscosity cst all 521 models Dispensing time lt 10 s 50 300 Silicone oil Dispensing strength lt 3 kg ee ee nee Cinematic viscosity is indicated in centistokes cst The dynamic viscosity in centipoises cps is obtained by multiplying the cinematic viscosity by the density of the liquid kg m zu em nun ose nn rm Threaded adapter PP
19. pfohlen den Dispenser nie l ngere Zeit auf einer Flasche zu lassen welche konzentrierte starke S uren enth lt und das Ger t nach Gebrauch gut zu sp len Die Empfehlung ist ebenfalls f r fl chtige L sungs mittel g ltig Ein langfristiger Produktverlust kann dadurch verhindert werden Verursachte Sch den durch nicht kompatibel Rea genzien sind von der Garantie ausgeschlossen Im Zweifelsfalle muss der Anwender vor dem Einsatz die chemische Vertr glichkeit berpr fen oder dem Hersteller anfragen GARANTIE Der Calibrex 521 Dispenser wird f r die Dauer von einem Jahr f r st rungsfreien Betrieb bei sachge m ssem Gebrauch garantiert Bei Glasbruch oder bei Missachtung der Angaben der Betriebsanwei sung und den Sicherheitsvorschriften werden s mtliche Garantieanspr che ausgeschlossen Re paraturen und neue Ersatzteile verl ngern die Ga rantiezeit nicht Falls St rungen vorliegen die nach genannten Hin weisen nicht zu beseitigen sind senden Sie das In strument nach Vereinbarung an ihren Fachh ndler zur ck Das Instrument vor der R cksendung sp len und desinfizieren En cas de blocage ou de course difficile du piston d monter l instrument et tremper les pi ces dans une solution d tergente pour le laboratoire Les rin cer puis contr ler le bon fonctionnement apr s re montage Ne jamais forcer un piston bloqu au risque de casser le cylindre de verre mais le mettre tremper dans une solution d
20. tains no liquid by depressing plunger down to lower stop Re move dispenser from the bottle and prime if neces sary Remove feed tube No 9 Unscrew stop screw No 12 and pull cap No 1 to take out plunger from barrel Unscrew ring No 19 and pull dispenser body No 5 This allows access to bar rel No 4 Remove delivery jet No 13 to access to valve No 10 After reassembling make sure the dispenser works properly Damaged parts should be exchanged us ing Original spare parts only Cleaning Clean fluid path of the dispenser regularly i e whenever the bottle has been emptied or before dosing another liquid DOSIEREN Einstellen des Volumens Das gewahlte Volumen wird im Fenster der Fuh rungsstange Nr 7 angezeigt Abb 2 Aussenman tel Nr 2 drehen bis die gewunschte Zahl im Fenster sichtbar ist Die richtige Stellung wird durch ein deutliches Einrasten gekennzeichnet Aussenman tel mit einer Hand festhalten und mit der anderen Hand Vernier Ring Nr 16 drehen bis die gewunsch te Zahl im Fenster sichtbar ist Die Einstellung ist richtig wenn die beiden Zahlen auf einer Linie ste hen Gerat entliften Um alle Luftblasen aus der Ausstosskanule zu ent fernen Handstuck einmal bis zum obersten An schlag ziehen und dann 2 bis 3 mal kurz betatigen Die w hrend der Inbetriebnahme aufgepumpte Flussigkeit kann in einem sauberen Behalter ge sammelt und wieder verwendet werden Dosiervorgang Verschlusskappe Nr 14 abnehmen Durc