        ZIRCON 34 Woodburning Assemblage et l
         Contents
1.    Adaptateur mural simple    Chemin  e  gt  bo  te de support  A    t  le Vis   3 minimum pb       T            Glissez Connector  Vis    t  le Connecteur de   glissement connecteur 2  chemin  e     DuraVent 8DVL   ADC ou 8878 Adaptateur  ICC Excel Prolongement de conduit   8EX    Selkirk Stovepipe Adaptateur   Ou un adaptateur mural simple Chemin  e    ADAPTATEUR NON FOURNI PAR MALM    Tuyau Moyen Section Bas  Se inscrit dans la section     p  amortisseur    DuraVent  8878      ICC Excel  Amortisseur En basde tuy  8EX    aux Convient dans l unit            Tuyau de raccordement Malm est congu  pour   tre ensemble sans requireing    Unite       fastners entre les sections du raccord     L illustration ci dessus repr  sente la proc  dure d installation pour l installation de la conduite anti goutte  cette  installation Proc  d   d installation du tuyau de raccordement avec l extr  mit   m  le vers le bas permet    l humidit   de  rester sur le    l int  rieur du tuyau du connecteur        premi  re vue  vous pouvez se inqui  ter que la fum  e se   chappe du tuyau et entrer dans la salle  Ce ne est  pas la fa  on dont le syst  me fonctionnera  Le vide dans le syst  me de chemin  e sera toujours aspirer l air dans  la chemin  e  Si vous rencontrez un courant descendant avec votre installation  il indique que la hauteur de la  chemin  e suppl  mentaire ou une sp  cialit   projet bouchon   tre ajout  s    votre syst  me de chemin  e  Contactez  votre revendeur pour de plus amples
2.   Center of Connector to Sidewall   Connector to Backwall   Center of connector to Backwall    Minimum Hearth Size 50    x 32     Hearth is not required to extend under the Zircon   s base     FIGURE 1 FIGURE 2    Hearth dimensions shown are minimum requirements  It may be desired to exceede these mini   mum dimensions for a more decorative installation  The hearth material must be 3 8    or thicker  noncombustible material  It is not required for the hearth material to extend under the base of the  fireplace     ZIRCON 34 WOODBURNING 10 15       ASSEMBLY AND INSTALLATION INSTRUCTIONS Continued    DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE    This stove must be connected to  1  a chimney complying with the requirements for Type HT chimneys in  the Standard for Chimneys  Factory Built  Residential Type and Building Heating Appliance  UL 103  or  2   a code approved masonry chimney with a flue liner     DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM     Chimney Connector Installation   The connector pipe included with the Zircon is 1   8    x 24    damper pipe  1   8    x 24    pipe section and  1   8          24    slip connector  The slip connector is identified by 3 holes at the top of the pipe  The slip  connector has one flair at the top with the 3 holes  The bottom is smooth  The damper section and  intermediate pipe section have flairings at both ends  The male end is always at the bottom     Simpson Dura Vent Chimney System  It is requir
3.   charge un extincteur chimique sec dans l ouverture du foyer  Si un extincteur ne est pas disponible  m  langer  bicarbonate de soude dans l   ouverture  Ne pas verser de l   eau sur le feu      Fermez toutes les prises d   air    la chambre de combustion et laisser ferm   jusqu    ce que la chemin  e  po  le ou tuyau de  po  le est compl  tement refroidi      Surveillez les   tincelles sur le toit  Si n  cessaire  arroser le toit autour de la chemin  e  NE PAS verser de l   eau  ou vers le bas sur la chemin  e      Une fois le feu est compl  tement   teint  inspecter la chemin  e pour tout signe de dommages  Si vous n   tes pas certain   demandez    votre service d incendie local inspecter la chemin  e pour vous  Ne jamais utiliser un liquide inflammable pour  allumer ou raviver un feu      Ne utilisez jamais de charbon dans une chemin  e  Coal doit   tre utilis   que dans les po  les sp  cialement con  us pour  br  ler du charbon  Si le toxiques gaz produits entrent dans la salle  ils peuvent   tre mortels        Page   15 ZIRCON 34 WOODBURNING 10 15    INSTRUCTIONS DE MAINTENANCE  Manquement a utiliser correctement et de maintenir cet appareil peut annuler la  la garantie du fabricant et pourrait provoquer un incendie de maison     1  Toujours garder la zone autour de l   unit   propre et claire de meubles et d autres objets  Gardez tous les meubles d   un  minimum de 48 pouces de l appareil de chauffage    2  P  riodiquement l unit   enti  re  connecteur chemin  e  et de
4.  5 ZIRCON 34 WOODBURNING 10 15       MASONRY THIMBLE    2    Clearance From Studs  To Chimney Walls    2    Of Brick From Liner  To Combustibles    5 8    Fireclay Liner  Minimum or Equivalent    Z gt  i  12    Of Brick From Liner  12    Minimum To Combustibles    Sill Support    Figure 4    ZIRCON 34 WOODBURNING 10 15       OPERATING INSTRUCTIONS    Failure to properly use and maintain this appliance may void the  manufacturer   s warranty and could result in a house fire     CAUTION  HOT WHILE IN OPERATION  DO NOT TOUCH  KEEP CHILDREN  CLOTHING AND FURNITURE  AWAY  CONTACT MAY CAUSE SKIN BURNS  SEE NAMEPLATE AND INSTRUCTIONS     Do Not over fire   If any portion of the unit or flue starts to glow you are over firing  This is a free standing fireplace  do not use for  any other purpose     1  The first few fires should be small in order to properly cure the painted surfaces and refractory  During the  first few fires  some smoking may occur as the paint cures  You may wish to open a window to minimize  discomfort during this curing period    DO NOT BURN TRASH OR GARBAGE IN THIS UNIT  When building a fire  be sure the damper is fully  opened and sufficient combustion air is available  Place dry kindling on dry wadded paper then ignite with  a match  Add progressively larger pieces of wood until the fire is well established  Leave the damper fully  open  Close only after the fire has burned out completely  Add additional firewood as needed to maintain  the fire    The fire scr
5.  Ne pas br  ler rebuts ou des d  chets dans cette unit    Lors de la construction d un incendie  se assurer que le  registre est enti  rement ouvert et suffisamment d air comburant est disponible  Placez du petit bois sec sur papier ouat    s  che ensuite enflammer un match  Ajouter progressivement plus grands morceaux de bois jusqu      ce que le feu soit bien    tabli  Laissez le registre compl  tement ouverte  Fermer seulement apr  s le feu a br  l   compl  tement  Ajouter bois  suppl  mentaires au besoin pour maintenir le feu    3  L   cran de feu doit   tre en place pendant les op  rations  CE FOYER FERM   N A PAS ETE TEST      UTILISER AVEC  PORTES  POUR REDUIRE LES RISQUES D   INCENDIE OU DE BLESSURES  NE PAS INSTALLER PORTES    4  Ne utilisez pas de grille ou d     lever INCENDIE  Construire le feu directement sur Hearth    5  Gardez l   amortisseur de tuyau dans la position compl  tement ouverte lorsque le foyer est utilis      6  ATTENTION  Le chauffage de l air dans un b  timent ferm   diminue l humidit   relative de lair  qui va s  cher le bois  et d   autres mat  riaux combustibles  Ce s  chage r  duit la temp  rature d   inflammation de ces mat  riaux ainsi  augmentant les risques d incendie  Pour r  duire le risque d incendie  certaines dispositions doivent   tre prises pour  reconstituer l humidit      l   air chaque fois que la structure est chauff  e pendant de longues p  riodes      Assurez vous de fournir de l air de combustion dans le logement lors de l  
6.  de type r  sidentiel et appareil de chauffage  UL 103  ou  2  d   une  chemin  e en ma  onnerie de code approuv   avec une chemise de combustion     NE PAS RACCORDER A UN CONDUIT DE DISTRIBUTION D   AIR OU SYST  ME     Installation raccord de chemin  e   Le tuyau de raccordement fourni avec le Zircon est 1 8 pipe    x 24    d   amortisseur  1 8 section    x 24    de la conduite   et Connecteur 8    x 24    de glissement   1  Le connecteur de glissement est identifi   par trois trous dans le haut de la  conduite  Le connecteur de glissement a une ambiance au sommet  avec les trois trous  Le fond est lisse  La section  de l   amortisseur et la section interm  diaire de tuyau ont flairings aux deux extr  mit  s  L   extr  mit   m  le est toujours  au fond     Simpson Dura Vent Syst  me Chemin  e   It is required to use a Dura Vent Universal Connector part number 8878 to install the chimney connector    1  Le connecteur universel est install   dans la zone de soutien  Le tuyau 203mm x 610mm de glissement est  ensuite raccord   au connecteur universel    2  La section de tuyau interm  diaire 203mm x 610mm est alors gliss   sur le tuyau de raccordement de glissement   Faites glisser le tuyau de 24 pouces sur le tuyau juste assez fort que n  cessaire de glissement pour   faciliter l installation de la conduite 203mm       610mm d   amortisseur    l unit      3  Faites glisser le tuyau 203mm x 610mm vers le bas sur le tuyau d   amortisseur install   sur le Zircon    4  Il doit y avo
7.  informations concernant les courants descendants     Liste du mat  riel   Inclus avec le Zircon 34 est la suivante    1   203mm x 610mm tuyau d   amortisseur   1   203mm x 610mm section de tuyau 1   203mm       610mm tuyau de  la section de glissement 4   6 de sacs de Malmcrete r  fractaire     Page   13 ZIRCON 34 WOODBURNING 10 15       MACONNERIE THIMBLE    51mm D  gagement des  montants Pour  Chemin  e Murs    305mm De Brick D  Liner pour combus   tibles    5 8    15 8mm fireclay  Liner Minimum ou  equivalent     K r 305mm De Brick De  Liner pour combus   305mm    Minimum tibles    Figure 4    ZIRCON 34 WOODBURNING 10 15       MODE D EMPLOI    Manquement a utiliser correctement et de maintenir cet appareil peut annuler la  la garantie du fabricant et pourrait provoquer un incendie de maison     ATTENTION  CHAUD EN FONCTIONNEMENT  NE PAS TOUCHER  GARDEZ LES ENFANTS  LES V  TEMENTS ET LES  MEUBLES  LE CONTACT PEUT PROVOQUER DES BR  LURES CUTAN  ES  VOIR PLAQUE SIGNAL  TIQUE ET  LES INSTRUCTIONS    Ne pas sur le feu    Si une partie de l unit   ou de fum  e commence    briller vous   tes surchauffe  Ce est un foyer permanent libre  ne pas utiliser  pour toute autre fin     1  Les premiers feux doivent   tre petites pour gu  rir correctement les surfaces peintes et r  fractaire  au cours de la  premi  res incendies  de la fum  e peut se produire que les cures de peinture  Vous pouvez ouvrir une fen  tre pour  minimiser inconfort au cours de cette p  riode de durcissement     
8.  la chemin  e doit   tre inspect   pour les fuites  les pi  ces cas   s  es ou d  fectueuses  et les connexions desserr  es  Si des probl  mes sont constat  s  contactez votre revendeur pour  les services de r  paration  Ne pas faire fonctionner l appareil jusqu      ce que les r  parations ont   t   achev  es     Inspecter et nettoyer fr  quemment la chemin  e   sous certaines  CONDITIONS D UTILISATION  l   accumulation de cr  osote peut arriver rapidement     CREOSOTE FORMATION ET LA NECESSITE POUR LE RETRAIT   Lorsque le bois br  le lentement  il produit du goudron et d   autres vapeurs  qui se combinent avec l humidit   pour former la  cr  osote  Vapeurs de cr  osote se condensent dans le conduit de chemin  e relativement froid  et les r  sidus de cr  osote  se accumulent sur les parois du conduit  Lorsqu elle se enflamme  la cr  osote peut faire un feu extr  mement chaud  Le  connecteur de chemin  e et la chemin  e devraient   tre inspect  s au moins deux fois par mois pendant la saison de chauffage    pour d  terminer si l accumulation de cr  osote se est produite  si cr  osote se est accumul  e  elle doit   tre enlev  e pour r  duire  le risque d   un feu de chemin  e     COMMENT FAIRE POUR SUPPRIMER LA CREOSOTE      Nettoyez la chemin  e avec des brosses et   quipements disponibles dans les magasins de chemin  e locales      chimiques nettoyage des chemin  es sont utilis  s en les ajoutant    l incendie  mais ils ne sont pas destin  s      tre utilis  s dans  les chem
9.  result in a house fire     Always keep the area around the unit clean and clear of furniture and other objects  Keep all furniture a minimum of 48  inches away from the heater    Periodically the entire unit  chimney connector  and chimney system must be inspected for leaks  broken or malfunction   ing parts  and loose connections  If any problems are noted  contact your dealer for repair services  Do not operate the  unit until repairs have been completed     INSPECT AND CLEAN CHIMNEY FREQUENTLY   UNDER CERTAIN  CONDITIONS OF USE  CREOSOTE BUILDUP MAY OCCUR RAPIDLY     CREOSOTE FORMATION AND THE NEED FOR REMOVAL     When wood is burned slowly  it produces tar and other vapors  which combine with moisture to form creosote   Creosote vapors condense in the relatively cool chimney flue  and creosote residue accumulates on the flue lining   When ignited  this creosote can make an extremely hot fire  The chimney connector and chimney should be  inspected at least twice monthly during the heating season to determine if creosote buildup has occurred  If  creosote has accumulated  it should be removed to reduce the chance of a chimney fire     How TO REMOVE CREOSOTE     2    Clean the chimney with brushes and equipment available at local fireplace shops    Chemical chimney cleaners are used by adding them to the fire  but they are not intended for use in chimneys already  containing heavy soot deposits  Rather  they are intended to inhibit soot buildup  They can be used in metal ch
10.  utilisation ou de tout autre appareil de chauffage  au bois  Un partiellement fen  tre ouverte ou    l ext  rieur registre d   air dans le voisinage de l unit   seraient acceptables   L air de combustion doivent   tre fournis en conformit   avec le Code m  canique uniforme      ATTENTION  NE JAMAIS UTILISER D ESSENCE  TYPE ESSENCE LANTERNE ESSENCE  DE KEROSENE   BRIQUET  OU DE LIQUIDES POUR ALLUMER OU    RAVIVER    UN FEU DANS CET APPAREIL    GARDEZ TOUS CES LIQUIDES LOIN DU TOUT DE CHAUFFAGE EN UTILISATION        LIMINATION DES CENDRES  Les cendres devraient   tre plac  es dans un contenant m  tallique avec un couvercle  herm  tique  le ferm   r  cipient de cendres devrait   tre plac   sur un plancher incombustible ou sur le sol  loin de tout  mat  riaux combustibles  en attendant l   limination finale  Si les cendres doivent   tre   limin  s par enfouissement dans le  sol ou autrement dispers   localement  elles devraient   tre maintenues dans le r  cipient ferm   jusqu      ce qu elles soient  compl  tement refroidies    10  LIRE LES INSTRUCTIONS DE MAINTENANCE     EN CAS DE FEU DE CHEMINEE    Une installation et de soins suppl  mentaires s  re et correcte aidera    pr  venir un incendie  mais accepter l   id  e qu il pourrait  y avoir un incendie  Soyez pr  t    g  rer  Assurez vous que tout le monde dans la maison est familier avec les signes  annonciateurs d   un feu de chemin  e      Appelez les pompiers imm  diatement  avant de faire quoi que ce soit d   autre      D
11. AGED OR MISSING PARTS   Protect the flooring near the intended place of installation with an old rug  blanket  or cardboard  Place the firebox   on this material    Mix and install the Malmcrete hearth refractory as follows    a  Obtain a sturdy water tight mixing container such as a wheelbarrow or large wash tub  a bucket or can for  transporting the mixture  a cement trowel  and a source for clean mixing water  It is suggested that the  Malmcrete be mixed outside to avoid spillage or splatters in the dwelling    Pour the dry Malmcrete mixture into the mixing container    Use 1 quart water for each bag    Add 1 2 to 3 4 of the water to the dry mix and mix thourghly  Add additional water in small increments  mixing  throughly between additions  Do not add more water than is necessary to get a somewhat dry mixture  to much  water in the mix may cause the refractory to crack excessively  and will reduce the strength of the refractory    To test for proper water content  cut vertically into the mixture with the trowel  push the trowel sideways to open  a 3 inch deep by 2 inch wide cut in the mixture  then slide the trowel back up out of the cut  The cut should   stay open with very little    slumping    back into the cut  Next  run the trowel over the surface of the mixture with  the blade at a slight angle to the surface of the mixture  like spreading butter  The mixture should become  relatively smooth with few voids after 6 or 7 passes of the trowel using moderate pressure  W
12. Malm Fireplace  Inc   368 Yolanda Avenue   Santa Rosa  Ca  95404   707  523 7755 Fax   707  571 8036    ZIRCON 34  Wood SUralag    Tested to UL737  amp  ULC S627 00  Listed By LabTest        Tested to U L Standards      Tested to UL737  amp  ULC S627 00      C US  gt  for use in USA  amp  Canada                  1 ertifi   pour une utilisation aux    Etats Unis et Canada         Assembly And Installation Instructions  LEAVE THESE INSTRUCTIONS WITH THE OWNER     SAFETY NOTICE    If this fireplace is not properly installed  a house fire may result  To  reduce the risk of fire  follow the installation instructions     Contact local building or fire officials about restrictions and installation  inspection requirements in your area     This stove must be connected to  1  a chimney complying with the  requirements for Type HT chimneys in the Standard for Chimneys   Factory Built  Residential Type and Building Heating Appliance  UL 103   or  2  a codeapproved masonry chimney with a flue liner     Please read this entire manual before you install and use your new  fireplace     Failure to follow instructions may result in property damage  bodily  injury  or even death     DO NOT INSTALL THIS UNIT IN A MOBILE HOME     ZIRCON 34 WOODBURNING 10 15       ASSEMBLY AND INSTALLATION INSTRUCTIONS    Carefully remove all components from the shipping cartons and inspect for damage  If any damage is noted contact  the shipping company or your dealer immediately  DO NOT INSTALL THIS UNIT IF DAM
13. ater should not  float to the top of the mixture    Transfer the mixture to the hearth  floor  area inside the firebox  spreading the mixture out as it is added  Use  the trowel to spread the mix into the firebox area  Continue to add refractory until there is a minimum of 2 inches  thick over the entire hearth area  To measure the depth of the mix  place a piece of tape 2 inches from the pointed  end of a long nail  Insert the nail vertically through the mix every 6 inches  front to back and side to side  across  the hearth  the mix should come to a uniform height up the nail  at or slightly above the tape  Trowel in the nail  holes when completed    Allow the mix to cure at least 48 hours  Additional curing time is necessary in cool temperatures  The longer  Malmcrete is allowed to cure before the first fire is lit  the stronger and more durable it will become    Make the first 3 or 4 fires very small and of short duration to allow the refractory to adjust to the high temperature  of a fire     Hearth Requirements    A floor protector is required to protect the floor in front of the fireplace opening from sparks  The floor protector must  be a minimum of 3 8 inch thick non combustible material such as brick  concrete  slate  ceramic tile  or a listed floor  protection board such as Wonderboard or Homosote    The floor protector must extend a minimum of 16 inches in front of the fireplace opening and 8 inches to either side of  the fireplace  The Zircon has been designed to 
14. c  ramique   ou un plancher cot  e Comit   de la protection tels que Wonderboard ou Homosote    Le protecteur de plancher doit d  passer d   au moins 16 pouces    l   avant de louverture du foyer et 8 pouces de chaque c  t   de  la chemin  e  Le zircon a   t   con  u pour fournir une protection du sol  permettant pour la conception flexible de la mise en  foyer     D  gagements aux combustibles    Le Zircon n  cessite une autorisation de murs combustibles de 254mm mesur  es    l arri  re de l appareil  Pour localiser le  centre de la chemin  e de la mesure est de 406mm    partir de la paroi arri  re et 1245mm    la paroi lat  rale  Voir figure 1  page  3  Pour coin l installation du centre de la chemin  e est de 483mm  Voir la figure 2  page 3     D  gagement    des non  combustibles    La clairance de zircon    un mur combustible peut   tre r  duite une protection ad  quate de la paroi  M  thodes accept  es pour  le mur protection permettrait la r  duction des d  gagements   Pour l apparence   si vous le souhaitez un rev  tement de mur  incombustible peut plac   sur le mur  Le rev  tement devrait   tre compos   d   un conseil de protection de la paroi cot  e install    sur le fabricant sp  cifications  Panneaux de protection approuv  s au moment de cette publication sont Wonderboard  Dura  Rock and Homosote  Un mat  riau incombustible peut alors   tre plac   sur le panneau de protection de mur  Avec la plupart  des panneaux de protection contre la clairance peut   tre r  dui
15. ed to use a Dura Vent Universal Connector part number 8DVL ADC or 8874 to install the  chimney connector   The universal connector is installed into the support box  The 8    x 24    slip pipe is then connected  to the universal connector   The 8    x 24    intermediate pipe section is then slid over the slip connector pipe  Slide the 24 inch  pipe over the slip pipe only far enough as necessary to facilitate installation of the 8    x 24    damper  pipe in to the unit   Slide the 8    x 24    pipe down onto the damper pipe installed on the Zircon   There must be a minimum of 2 inches of overlap between the 8    x 24    and 8    x 24    slip connector  pipe   Metalbestos or Security  When using Metalbestos or Security chimney systems it is required to use the Metalbestos DS CPA or  8878 Single Wall Conector pipe  Security users must use the EX adapter     Installation of the Metalbestos DS CPA or the Security EX adapter must be done first   Attach the 8    x 24    slip connector to the DS CPA  8878 or EX adapter with 3    8 x 3 8 inch screws   The 8    x 24    pipe section is then slid into the slip connector pipe  Slide the 24 inch pipe into the  slip pipe only far enough as necessary to facilitate installation of the 8    x 24    damper pipe into the  unit   Slide the 8    x 24    pipe down onto the piece installed on the Zircon   There must be a minimum of 2 inches of overlap between the 8    x 24    and 8    x 24    slip connector  pipe   Other Chimney Systems  There are 
16. een must be in place during operations  THIS FIREPLACE STOVE HAS NOT BEEN TESTED  FOR USE WITH DOORS  TO REDUCE THE RISK OF FIRE OR INJURY  DO NOT INSTALL DOORS    DO NOT USE A GRATE OR ELEVATE FIRE  Build fire directly on Hearth    Keep the pipe damper in the full open position when the fireplace is being used    CAUTION  Heating the air in a closed building decreases the relative humidity of the air  which will dry wood  and other combustible materials  This drying lowers the ignition temperature of these materials thus  increasing fire hazards  To reduce the risk of fire  some provision should be made for replenishing moisture  to the air whenever a structure is being heated for extended periods    Be sure to provide combustion air into the dwelling when using this or any other wood burning appliance  A  partially open window or outside air register in the vicinity of the unit would be acceptable  Combustion air  must be supplied in conformance with the Uniform Mechanical Code    CAUTION  NEVER USE GASOLINE  GASOLINE TYPE LANTERN FUEL  KEROSENE  CHARCOAL  LIGHTER FLUID  OR SIMILAR LIQUIDS TO START OR    FRESHEN UP    A FIRE IN THIS HEATER   KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE HEATER WHILE IN USE    DISPOSAL OF ASHES  Ashes should be placed in a metal container with a tight fitting lid  The closed  container of ashes should be placed on a noncombustible floor or on the ground  well away from all  combustible materials  pending final disposal  If the ashes are to be dis
17. imneys  provided the manufacturers instructions are strictly followed  Generally these commercial cleaners are quite effective   Call a professional chimney sweep in your area  They possess the experience and tools necessary to make the task  easy     Maintenance other than the items specifically mentioned herein are to be performed by a qualified serviceman  only  Contact your dealer  For further information on using your heater safely  obtain a copy of the National Fire  Protection Association publication    Using Coal and Wood Stoves Safely     NFPA HS 10 1978  The address of  the NFPA is Batterymarch Park  Quincy  MA 02269  File these instructions for future reference     NEVER STORE OR ALLOW PAPERS  KINDLING  FIREWOOD OR  ANY OTHER COMBUSTIBLES WITHIN 48 INCHES OF UNIT     M Malm Fireplaces  Inc     368 Yolanda Avenue  Santa Rosa  Ca 95404   707  523 7755    800  535 8955  Fax   707  571 8036  www malmfireplaces com  info malmfireplaces com    Page   8 ZIRCON 34 WOODBURNING 10 15       Malm Fireplace  Inc   368 Yolanda Avenue   Santa Rosa  Ca  95404   707  523 7755 Fax   707  571 8036    ZIRCON 34  Woodlburaing    Certified for use in USA  amp  Canada    Etats Unis et Canada      Certifi   pour une utilisation aux         Listed By LabTest    i   6 US Tested to U L Standards                    1 Tested to UL737     0    Assemblage et l installation Instructions  Laisser ces instructions avec le propri  taire     AVIS DE SECURITE    Si ce foyer ne est pas install   correc
18. in  es contenant d  j   des d  p  ts de suie  Plut  t  ils sont destin  s    inhiber l accumulation de suie  Ils peuvent   tre  utilis  s dans les chemin  es m  talliques pr  vues les instructions du fabricant sont strictement suivies  G  n  ralement  ces  nettoyants commerciaux sont tr  s efficaces      Appeler un ramoneur professionnel dans votre r  gion  Ils poss  dent l exp  rience et les outils n  cessaires pour rendre la t  che  facile    Entretien autre que les articles sp  cifiquement mentionn  s dans ce document sont    effectuer par un technicien qualifi    seulement  Contactez votre revendeur  Pour de plus amples informations sur l   utilisation de votre appareil en toute  s  curit    obtenir une copie de la National Fire   Publication Protection Association   Utilisation du charbon et de bois Po  les en toute s  curit      NFPA HS 10 1978   L adresse de la la NFPA est Batterymarch Park  Quincy  MA 02269  Fichier ces instructions pour r  f  rence future     Ne rangez jamais O   LAISSER papiers  POELE  bois de chauffage ou  D   AUTRES COMBUSTIBLES dans les 48 POUCES de l   appareil     M Maim Fireplaces     368 Yolanda Avenue  Santa Rosa  Ca 95404   707  523 7755    800  535 8955  Fax   707  571 8036  www malmfireplaces com  info malmfireplaces com       ZIRCON 34 WOODBURNING 10 15    
19. ir un minimum de deux pouces de chevauchement entre les 203mm x 610mm et 203mm x 610mm   tuyau de raccordement de glissement     Metalbestos ou de S  curit     Lors de l   utilisation Metalbestos ou syst  mes de chemin  es de s  curit    il est n  cessaire d utiliser le tuyau   Metalbestos DS CPA simple mur Conector  Les utilisateurs de s  curit   doivent utiliser l adaptateur EX    1  Installation du Metalbestos DS CPA or 8878 ou l adaptateur de s  curit   EX doit   tre fait en premier    2  Fixez le connecteur 203mm       610mm de glissement    la DS CPA ou un adaptateur avec 3         8 x 3 8 pouces vis    3  L article 203mm x 610mm de tuyau est ensuite gliss   dans le tuyau de raccordement de glissement  Faites  glisser le tuyau de 24 pouces dans le tuyau juste assez fort que n  cessaire de glissement pour faciliter   l installation de la conduite 203mm x 610mm d   amortisseur dans l unit      4  Faites glisser le tuyau 203mm x 610mm vers le bas sur la pi  ce install  e sur le Zircon    5  Il doit y avoir un minimum de deux pouces de chevauchement entre les 203mm x 610mm et 203mm x 610mm   tuyau de raccordement de glissement Autres Syst  mes de chemin  e   ya beaucoup d   autres fabricants de syst  mes de chemin  es  Il est au del   de la port  e de cette publication pour           couvrir l installation avec tous les diff  rents syst  mes disponibles  La plupart des syst  mes ont une m  thode de   connexion au tuyau de raccordement du zircon  Confirmer les m  thodes d in
20. many other manufacturer   s of chimney systems  It is beyond the scope of this publication to  cover installation with all of the different systems available  Most systems have a method of connection to  the Zircon   s connector pipe  Confirm installation procedures with your dealer or the manufacturer of the  chimney system you have purchased     Masonry Chimney   If using a masonry chimney  it must meet the minimum standards of the National Fire Protection  Association  NFPA  Standard 211  The chimney must have at least a 5 8    fire clay liner or a listed chimney  liner system  The chimney must be inspected for cracks  loose mortar  or any other signs of deterioration   It is best to have the chimney inspected by a professional  Make certain the chimney is cleaned prior   to installation of this fireplace  The size of the chimney should be between 36 and 96 square inches   Larger chimneys should be relined to meet these requirements  Incorrect sizing of the chimney may  affect the draft and result in poor fireplace performance  Do not install more than one appliance to any  chimney  There are different accepted methods of connecting the fireplace to a masonry chimney through  a combustible wall  This type of installation requires the use of a thimble to protect the surrounding  combustible materials  Check with your local building officials or consult NFPA211  See Figure 4  Page 6     Page   4 IMPERIAL CAROUSEL 5       Chimney Connector Instructions    Type HT Insulated Pi
21. nche    l   eau solide comme une brouette ou grand bain de lavage  un seau ou peut  par transport du m  lange  une truelle de ciment  et une source d   eau propre de g  chage  II est sugg  r   que le  Malmcrete   tre m  lang      l ext  rieur pur   viter les fuites ou   claboussures dans le logement    b  Verser le m  lange Malmcrete sec dans le r  cipient de m  lange    c  Utiliser de l   eau de 1 quart pour chaque sac    d  Ajouter 1 2    3 4 de l   eau au m  lange sec et m  langer thourghly  Ajouter de l   eau dans de petits incr  ments  le m  lange  throughly entre les ajouts  Ne pas ajouter plus d   eau que ce qui est n  cessaire pour obtenir un m  lange un peu sec   pour autant eau dans le m  lange peut provoquer le r  fractaire    craquer trop  et permettra de r  duire la force de la  r  fractaire    Pour tester la teneur en eau appropri  e  couper verticalement dans le m  lange    la truelle  pousser la truelle sur le c  t    pour ouvrir 3 pouce de profondeur de 2 pouces de large coupe dans le m  lange  puis faites glisser la truelle sauvegarde  de la coupe  La coupe doit rester ouvert avec tr  s peu de    l effondrement    de nouveau dans la coupe  Ensuite  ex  cutez  la truelle sur la surface du m  lange avec la lame avec un l  ger angle a la surface du m  lange  comme la propagation de  beurre  Le m  lange doit devenir relativement lisse avec peu de vides apr  s six ou sept passes de la truelle en utilisant  une pression mod  r  e  Eau ne devrait pas flotter    la 
22. pe           Chimney System    Single Wall Chimney Adapter        Support Box _ evr  Sheet Metal        M   Screw   3 Minimum  Slip Connector   Sheet Metal Screw to  gt  Slip Connector      Chimney Connector     DuraVent 8DVL ADC or 8878 Adapter  ICC Excel Flue Extension  8EX   Selkirk Stovepipe Adaptor  Middle Pipe Section Bottom ge Or Single Wall Chimney Adapter  Fits Into Damper Section ADAPTER NOT INCLUDED FROM MALM    DuraVent  8878    Damper Pipe Bottom gg ICC Excel  Fits Into Unit 8EX    Unit Malm connector pipe is designed to  4 fit together without requireing fastners  between the connector sections     The above illustration represents the installation procedure for dripless pipe installation  This installation  method of installing the connector pipe with the male end down allows for any moisture to remain on the  inside of the connector pipe     At first glance you may become concerned that smoke will escape the pipe and enter the room  This is not how  the system will work  The vacuum in the chimney system will always pull air into the chimney  If you experience a  downdraft with your installation it indicates that additional chimney height or a specialty draft cap be added to your  chimney system  Contact your dealer for further information regarding downdrafts     Material List  Included with the Zircon 34 is the following   1   8       24 damper pipe  1   8       24 pipe section  1   8       24 slip section pipe  4   6lb bags of Malmcrete refractory     Page  
23. posed of by burial in soil or otherwise  locally dispersed  they should be retained in the closed container until all cinders have thoroughly cooled    10  READ MAINTENANCE INSTRUCTIONS     IN CASE OF A CHIMNEY FIRE    A safe and correct installation and extra care will help prevent a fire  but accept the idea that there could be a fire   Be prepared to handle it  Make certain everyone in the house is familiar with the warning signs of a chimney fire     Call the Fire Department immediately  before doing anything else    Discharge a dry chemical extinguisher into the fireplace opening  If an extinguisher is not available  toss  baking soda into the opening  Do not pour water on the fire    Close all air intakes to the firebox and leave closed until the fireplace  stove or stove pipe is completely cooled   Watch for sparks on the roof  If necessary  hose down the roof around the chimney  DO NOT pour water   down or on the chimney    After the fire is completely out  inspect the chimney for any signs of damage  If you are not certain  have your  local Fire Department inspect the chimney for you  Never use a flammable liquid to kindle or rekindle a fire   Never use coal in a fireplace  Coal should be used only in stoves especially designed to burn coal  If the toxic  gases produced enter the room they can be fatal     ZIRCON 34 WOODBURNING 10 15       MAINTENANCE INSTRUCTIONS    Failure to properly use and maintain this appliance may void the  manufacturer   s warranty and could
24. provide floor protection allowing for flexible design of the hearth setting     Clearance to Combustibles   The Zircon requires a clearance to combustible walls of 10    measured from the back of the unit  For locating the center  of the chimney the measurement is 12    from the backwall and 32    to the sidewall  See figure 1  page 3  For corner  installation the center of the chimney is 19     See figure 2  page 3     Clearance to Non combustibles   The Zircon clearance to a combustible wall may be reduced with proper wall protection  Accepted methods for wall  protection would allow reduction of the wall clearances  For appearance if desired a non combustible wall covering can  placed on the wall  The covering should consist of a listed wall protection board installed to the manufacturer   s  specifications  Approved protection boards at the time of this publication are Wonderboard  Dura Rock and Homosote   A non combustible material can then be placed over the wall protection board  With most of the protection boards the  clearance can be reduced to 8 inches from the original combustible wall  Be certain to check with your local building  officials and or fire inspector for accepted methods in your area  Refer to NFPA 211     ZIRCON 34 WOODBURNING 10 15       CLEARANCES    SIDEWALL AND BACKWALL INSTALLATION CORNER INSTALLATION    Unit to Sidewall Unit to Adjacent Wall   Unit to Backwall Connector to Adjacent Wall  Connector to Sidewall Center of Connector to Adjacent Wall
25. stallation avec votre revendeur ou le   fabricant du syst  me de chemin  e que vous avez achet      Chemin  e de Ma  onnerie    Si vous utilisez une chemin  e de ma  onnerie  il doit r  pondre aux normes minimales de la National Fire Protection  Association  NFPA  standard 211  La chemin  e doit avoir au moins une   couche d argile de feu 5 8 ou d un syst  me  de recouvrement de chemin  e  La chemin  e doit   tre inspect  e pour fissures  du mortier l  che  ou d   autres signes  de d  t  rioration  Il est pr  f  rable d   avoir la chemin  e inspect   par un professionnel  Assurez vous que la chemin  e  est nettoy  e avant l installation de ce foyer  La taille de la chemin  e doit   tre comprise entre 36 et 96 pouces  carr  s  Grandes chemin  es doivent   tre regarnis pour r  pondre    ces exigences  Mauvaise dimensionnement de  la chemin  e peut affecter le projet et entra  ner des performances de chemin  e pauvres  Ne pas installer plus d   un  appareil    ne importe quel chemin  e     existe diff  rentes m  thodes accept  es de raccordement de la chemin  e a  une chemin  e de ma  onnerie    travers un mur combustible  Ce type d installation n  cessite l   utilisation d un doigt  de gant pour prot  ger les mat  riaux combustibles environnants  V  rifiez aupr  s de votre administration locale de  construction ou consultez NFPA211  Voir Figure 4  Page 6     ZIRCON 34 WOODBURNING 10 15       Instructions RACCORDEMENT    Type HT tuyau isol   2    syst  me Chimney  plafond       
26. surface du m  lange    e  Transf  rer le m  lange dans la zone de po  le  au sol     l   int  rieur du foyer    pandant le m  lange comme il est ajout     Utilisation la truelle pour r  pandre le m  lange dans la zone du foyer  Continuer    ajouter r  fractaire jusqu      ce qu il y  ait un minimum de 2 pouces d   paisseur sur toute la surface de la sole  Pour mesurer la profondeur du m  lange  placez  un morceau de ruban 2 pouces de la pointe fin d   un long clou  Ins  rez le clou verticalement    travers le m  lange tous  les 6 pouces  avant vers l arri  re et de gauche    droite     travers le foyer  le m  lange doit venir    une hauteur uniforme  jusqu    l   ongle  ou l  g  rement au dessus de la bande  Truelle dans l   ongle trous une fois rempli      Laisser le m  lange durcir au moins 48 heures  Temps de durcissement suppl  mentaire est n  cessaire dans des  temp  ratures fra  ches  Plus Malmcrete est autoris      gu  rir avant le premier feu est allum    le plus fort et plus durable  il  va devenir      Faire les trois ou quatre premiers feux tr  s faible et de courte dur  e pour permettre le r  fractaire    se adapter    la  temp  rature   lev  e d   un incendie     Exigences pour les   tres    Un protecteur de plancher est n  cessaire pour prot  ger le sol en face de l ouverture du foyer des   tincelles   Le protecteur de  plancher doit avoir un minimum de 3 8 pouce d   paisseur mat  riau non   combustibles comme la brique  le b  ton  l   ardoise   les carreaux de 
27. te    8 pouces du mur combustible d   origine  Soyez certain de  v  rifier avec votre b  timent local fonctionnaires et inspecteur des incendies ou des m  thodes accept  es dans votre r  gion   Reportez vous    la norme NFPA 211        Page   10 ZIRCON 34 WOODBURNING 10 15    DEGAGEMENTS    FLANC ET INSTALLATION ARRIERE INSTALLATION EN COIN   Unit   de flanc Unit   au mur adjacent   Unit   de paroi arri  re Connecteur a Wall Adjacent  Connecteur a la paroi lat  rale Centre de connecteur a mur adjacent  Centre de connecteur a la paroi lat  rale  1245mm   Retour connecteur pour mur   Centre de connecteur 8 l   arri  re mur    Toutes les dimensions ci dessous sont en millim  tres     Taille minimum Hearth 1270 x 32     Foyers ne est pas n  cessaire pour se   tendre sous la base du Zircon     FIGURE 1 FIGURE 2    Dimensions de foyer indiqu  es sont des exigences minimales  Il peut   tre souhaitable de exceede  ces dimensions minimales pour une installation plus d  coratif  Le mat  riau de l   tre doit   tre 3 8     ou mat  riaux incombustibles plus   pais  Il ne est pas n  cessaire pour le mat  riau de foyer pour se    tendre sous le fond de la chemin  e     ZIRCON 34 WOODBURNING 10 15       MONTAGE ET INSTALLATION INSTRUCTIONS Suite    NE PAS RACCORDER CET APPAREIL a un conduit de chemin  e desservant un autre APPAREIL    Ce po  le doit   tre connect       1  une chemin  e se conformer aux exigences de type HT chemin  es dans la norme  pour les chemin  es  usine de construction 
28. tement   un incendie peut en  r  sulter  Pour r  duire le risque d   incendie  suivez les instructions  d   installation     Contactez le service des incendies a propos des restrictions et  exigences d   inspection d   installation dans votre r  gion     Ce po  le doit   tre connect   8   1   une chemin  e se conformer aux  exigences de type HT chemin  es dans la norme pour les chemin  es   usine de construction  de type r  sidentiel et appareil de chauffage  UL  103  ou  2   d   une chemin  e en ma  onnerie codeapproved avec une  chemin  e liner     Se il vous plait lire l   int  gralit   de ce manuel avant d    installer et  d   utiliser votre nouveau foyer     Le non respect des instructions peut entra  ner des dommages mat  riels   des blessures  voire la mort     NE PAS INSTALLER CET APPAREIL DANS UNE MAISON MOBILE     Peut   tre utilis   avec l    option M  16 Grille     ZIRCON 34 WOODBURNING 10 15       MONTAGE ET INSTALLATION INSTRUCTIONS     1  Retirez soigneusement tous les composants des cartons d   exp  dition et inspecter les dommages  Si un dommage est not    contacts   la compagnie maritime ou de votre revendeur imm  diatement  NE PAS INSTALLER CET APPAREIL SI pi  ce   endommag  e ou manquante      Prot  ger le plancher pr  s de l endroit pr  vu pour l installation avec un vieux tapis  une couverture  ou en carton  Placez le  foyer sur ce mat  riau     M  langer et installer le foyer r  fractaire Malmcrete comme suit    a  Obtenir un r  cipient de m  lange   ta
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Tactile Musique Manuel d`utilisation    APC Zenoah Switch User Manual  Annuaire des consultants  Argent Data Systems Tracker3 Family User`s Manual  Targus APA042UK  Buffalo Tools COJSAWBX User's Manual  Assembly Instructions and User Manual  3W9478F - Magnum XR9 Airless Sprayer  Mulch Lock HG-16000-1 Instructions / Assembly    Copyright © All rights reserved. 