        Page 1 of 2 55108, Rev. B January 2012
         Contents
1.  REF  Catalogue Number   Num  ro du lot  R  f  rence     x  Use Before Date  Quantity    A utiliser avant le  Quantit     CS  Do not resterilize  Nonpyrogenic    Ne pas rest  riliser  Apyrog  ne       Date of Manufacture    Single Use Only  Do not reuse    Date de fabrication  A usage unique  Ne pas r  utiliser   STERILE  Sterile  Do not use if package is damaged or open  i ATTENTION  Read instruction prior to use        St  rile  Ne pas utiliser si emballage est endommag   ou ouvert   STERILE E0  Ethylene oxide sterilized   St  rilis      oxyde d     thyl  ne   USA   CAUTION  Federal law  USA  restricts this device to sale by or on the order of a physician   ATTENTION  Conform  ment    la l  gislation am  ricaine  cet appareil ne peut   tre vendu que par un m  decin ou sur l   ordre d   un m  decin    ATTENTION  Lire toutes les instructions avant l emploi                             CALIFORNIA MEDICAL LABORATORIES  INC   1570 SUNLAND LANE   COSTA MESA  CA 92626   714 556 7365    
2. Luer m  le du circuit de perfusion de cardiopl  gie   AVERTISSEMENT   Avant la perfusion de la solution de cardiopl  gie  s assurer que la les canules et le circuit de perfusion de cardiopl  gie ne contiennent pas  d air   AVERTISSEMENT   Utiliser la pression la plus basse possible pour infuser la solution de cardiopl  gie afin de r  duire les risques d h  molyse  d emprisonnement  d air et de dommage aux vaisseaux    9     la fin de l intervention  retirer la canule en utilisant la technique chirurgicale appropri  e et r  parer lesite de canulation  Mettre au rebut la canule en respectant l usage    10  Si la canule de vaisseau est utilis  e pour v  rifier les fuites d une veine pr  lev  e  raccorder l embout Luer lock femelle de la canule de vaisseau    une seringue remplie de solution    sal  e st  rile  Ligaturer une extr  mit   de la veine  Ins  rer l autre bout de la veine sur un ou deux des embouts d ancrage de taillesdiff  rentes de l extr  mit   distale de la canule de  vaisseau  Ligaturer autour de l embout d ancrage pour fixer la veine    la canule de vaisseau  Remplir doucement la veine avec la solution sal  e st  rile pour d  tecter la pr  sence    ventuelle des fuites    AVERTISSEMENT   Ces produits sont con  us uniquement pour un usage unique  Ne pas les r  utiliser    ATTENTION   Conform  ment    la l  gislation am  ricaine  cet appareil ne peut   tre vendu que par un m  decin ou sur l   ordre d un m  decin                                      Lor  Lot number 
3. Page 1 of2  55108  Rev  B  January 2012  VESSEL CANNULAE   VC X20X0   VC 12010 Vessel Cannula with Blunt Tip  VC 12020 Vessel Cannula with Blunt Tip  VC 22010 Vessel Cannula with Beveled Tip  VC 22020 Vessel Cannula with Beveled Tip    DIRECTIONS FOR USE       Single Use Only    Do not reuse  Do not resterilize    Do not use if package is damaged or open   Ethylene Oxide Sterilized  Non pyrogenic   Store in a cool  dry place     WARNING  Read Directions carefully before using this device     DESCRIPTION   California Medical Laboratories  Inc   second generation Vessel Cannula is indicated for use in the delivery of cardioplegia solution during cardiopulmonary bypass surgery  or to help check  for leaks in a harvested vein  which will be used for a graft  The cannula   s sleek  lower profile design has been revamped with a more flexible  tapered  polyvinyl chloride tube with  atraumatically designed distal tips  The improved distal tip features a double barbed design to accommodate vessels of various diameters and is available with a blunt or beveled tip  The  proximal luer connection is designed to securely connect with a standard Cardioplegia delivery line  The Vessel Cannula is available with or without a check valve     VC 12010  VC 22010        VC 12020  VC 22020    1  Blunt Tip   3    5  Blunt Tip with Integral Proximal Luer  2  One way valve    gt  6  Beveled Tip with Integral Proximal Luer  3  Proximal Luer cap  4  Beveled Tip      INDICATIONS FOR USE    California Med
4. el onto the Cannula    WARNING  Properly affix the Cannula to the vessel or tissue to prevent inadvertent removal during use    Back flush the Cannula to remove air    Prime the cardioplegia delivery circuit and attach it to the luer connection of the previously attached Cannula    8  Securely connect the proximal luer connection of the Cannula to the male luer connector of the cardioplegia delivery circuit    WARNING  Ensure that the Cannula s  and cardioplegia delivery circuit is free of air prior to delivery of cardioplegia solution   WARNING  The Lowest possible pressure should be used to infuse cardioplegia solution to minimize hemolysis  air entrapment and  damage to the vessels    9  Upon completion of the procedure  remove the Cannula using appropriate surgical technique and repair that surgical site  Discard the Cannula properly    10  If vessel cannula is being used to check for leaks in a harvested vein  connect the proximal luer lock of the vessel cannula to a syringe filled with sterile saline solution  Tie off one  end of the vein with suture  Insert the other end of the vein over one or both of the different sized anchor hubs of the distal tip of the vessel cannula  Place an anchoring suture  around the anchoring hub to secure the vein on to the vessel cannula  Gently fill the vein with sterile saline solution and check for any leaks    WARNING  These products are designed for single use only  Do not reuse product    CAUTION  Federal  USA  law restricts this de
5. ical Laboratories  Inc   Vessel Cannulae is indicated for the delivery of cardioplegia solution during cardiopulmonary bypass surgery or to help check for leaks in a harvested   vein which will be used for a graft    CONTRAINDICATIONS   California Medical Laboratories  Inc   Vessel Cannulae is not designed  sold or intended for use other than indicated    DIRECTIONS FOR USE   1  Remove the Vessel Cannula from the packaging using aseptic technique    2  After removing the Vessel Cannula from the packaging  inspect the packaging and product for damage    WARNING  If the packaging is damaged  do not use as sterility of the device may have been compromised    WARNING  Inspect the product for damage prior to use  Damage to the product  i e   crimps  distortions or cuts  may result in obstruction or disruption of flow during  use and product performance may be affected  Do not use damaged product    WARNING  Proper surgical procedure and technique is the responsibility of the attending medical professional  physician   This guideline is furnished for  informational purposes only  Each surgeon must evaluate the appropriate use of this device  case by case  based upon medical training  experience  and the type of  surgical procedure employed    Flush the Cannula    Using appropriate surgical technique  introduce the Cannula   s distal flow tip into cannulation site s  and secure in place    5  An anchoring suture may be placed proximally around to the anchoring hub to secure the vess
6. n tube de chlorure de  polyvinyle avec atraumatique con  us extr  mit  s distales  La pointe distale am  lior  e dispose d un design    double barbel  s pour accueillir des navires de diff  rents diam  tres et est disponible  avec une pointe   mouss  e ou biseaut    La connexion proximale Luer est con  u pour connecter en toute s  curit   avec une ligne de livraison de cardiopl  gie standard  La canule navire est  disponible avec ou sans clapet anti retour     VC 12020  VC 22020  5  La pointe   mouss  e avec Integral Proximale Luer    VC 12010  VC 22010       6  Embout Biseaut   avec Integral Proximale Luer    1  La pointe   mouss  e  2  Valve    3  Proximale Bouchon Luer  lt   4    Embout Biseaut          INDICATIONS   La canule de vaisseau de California Medical Laboratories  Inc  est indiqu  e pour l administration d une solution de cardiopl   gie lors d une intervention chirurgicale    circulation extra corporelle  et pour aider    v  rifier les fuites d une veine pr  lev  e devant   tre utilis  e dans une greffe    CONTRE INDICATIONS   La canule de vaisseau de California Medical Laboratories  Inc  n est pas congue  vendue ni destin  e a   tre utilis  e autrement que l emploi indiqu       MODE D EMPLOI   1  Sortir la canule de vaisseau de son emballage en utilisant une technique aseptique    2  Apr  s avoir sorti la canule de vaisseau de son emballage  inspecter la pochette et le produit pour en v  rifier l int  grit     AVERTISSEMENT   Si l emballage est endommag    ne pa
7. s utiliser car la st  rilit   du dispositif n est plus garantie   AVERTISSEMENT   Inspecter soigneusement le produit pour en d  tecter les dommages   ventuels avant son emploi  Des dommages au produit  c     d   les  pincements  les d  formations ou les coupures peuvent entra  ner l obstruction ou l interruption du d  bit pendant l utilisation  affectant les performances du  produit  Ne pas utiliser un produit endommag     AVERTISSEMENT   La responsabilit   du mode op  ratoire et de la technique chirurgicale appropri  e incombe au m  dical traitant  Ces directives n ont qu un but  indicatif  Chaque chirurgien doit   valuer l emploi appropri   de ce dispositif  cas par cas  en fonction de sa formation m  dicale  de son exp  rience et du type  d intervention chirurgicale pratiqu  e    3  Purger la canule    4  En utilisant la technique chirurgicale appropri  e  placer l extr  mit   distale de la canule dans le ou lessites de canulation et fixer solidement en place    5  Une ligature solidaire peut   tre effectu  e proximalement autour de l embout d ancrage pour fixer le vaisseau sur la canule   AVERTISSEMENT   Fixer correctement la canule au vaisseau ou au tissu pour   viter un retrait par inadvertance lors de l utilisation    6  Inverser le sens du flux de la canule pour   liminer l air du tube    7  Amorcer le circuit de perfusion de cardiopl  gie et le fixer au raccord Luer de la des canules fix  es au pr  alable    8  Raccorder solidement le raccord Luer femelle au raccord 
8. vice to sale by or on the order of a physician    PRECAUTION  This device was designed for single patient use only  Do not reuse  reprocess  or resterilize this product  Reuse  reprocessing  or resterilization may  compromise the structural integrity of the device and or create a risk of contamination of the device  which could result in patient injury  illness  or death     Ep    Sr    CALIFORNIA MEDICAL LABORATORIES  INC   1570 SUNLAND LANE   COSTA MESA  CA 92626   714 556 7365    Page 2 of 2  55108  Rev  B    January 2012  CANULE DE VAISSEAU   VC X20X0    VC 12010 Canule de vaisseau  avec la pointe   mouss  e  VC 12020 Canule de vaisseau  avec la pointe   mouss  e  VC 22010 Canule de vaisseau  avec embout biseaut     VC 22020 Canule de vaisseau  avec embout biseaut     MODE D EMPLOI    A usage unique     Ne pas r  utiliser  Ne pas rest  riliser    Ne pas utiliser si l emballage est endommag   ou ouvert   St  rilis      l   oxyde d     thyl  ne  Apyrog  ne    Conserver dans un endroit frais et sec     AVERTISSEMENT   Lire avec attention le mode d emploi avant d utiliser ce dispositif     DESCRIPTION   La canule veineuse California Medical Laboratories  Inc est indiqu   pour une utilisation dans la livraison de la solution de cardiopl  gie lors d un pontage cardiopulmonaire  ou pour aider     v  rifier les fuites collect  es dans une veine qui va   tre utilis   pour une greffe  La canule est lisse  conception de profil bas a   t   remani   avec un plus souples effil  es  d u
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Reinscriptions 2014 Mode d`emploi 1er degre  手押しポンプ ZO-Ⅲ/SUNTIGER  EdgeStar ap12000s User's Manual  guarde estas instrucciones  Nintendo 69178A User's Manual  Kingston Technology ValueRAM Memory 256MB 533MHz DDR2 CL4 MicroDIMM  1998 Sidekick FSM - Drivetrain Manual  SIE Derecho Público, SIE-DP  V7 CAT5e Cable RJ45 STP Shielded Black 0,5 m  Bluetooth HD Soundbar with Detachable Wireless Speakers    Copyright © All rights reserved. 