Home
AFD Manhattan Outdoor Fireplace Instructions
Contents
1. Fig 16 2 Place top panel a Installation continued on next page For propane models this is the only flex connector K gt L DO NOT fu slide housi _ into place lly ng A 3 I A Fig 16 5 Route flex to burner and connect FIREPLACE INSTALLATION cont Connect Gas Supply Important Before installation be sure the gas supply propane or natural is turned off at its source The fireplace has a key valve pre installed on the left side of the housing piece An L P regulator hose assembly OR a flex connector is pre installed to the key valve on the interior of the housing piece See Fig 17 1 To Connect to a Propane Cylinder Note L P fireplace models are equipped with a storage door on the left side of the unit see Fig 17 1 To remove the storage door first turn the door handle counter clockwise then carefully pullthe door outward Store in a safe location 1 Locate the L P regulator hose assembly that is already installed on the rear of the valve assembly Route the hose assembly through the hole in the housing to the propane cylinder Attach the regulator end of the hose assembly to a propane cylinder not included and tighten see Fig 17 2 and 17 3 The propane cylinder not included is to be located inside the firebox of the unit See Fig 17 3 The access door must be removed to place the cylinder Replace onc
2. 10 5 w c FOR PROPANE GAS The minimum inlet gas supply pressure for purposes of input adjustment is 8 w c and the maximum inlet gas supply pressure is 13 w c DO NOT INSTALL THE GAS APPLIANCE IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED The gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue pressure loss will occur if the pipe is too small or the run is too long Gas supply pipe must be 1 2 minimum interior diameter If the gas line is longer than 20 a larger diameter line may be necessary Refer to the NFPA 54 guidelines for further details For installations at elevations above 2 000 ft contact your local dealer or gas supplier before installing Input ratings should be reduced approximately 4 for each 1 000 ft above sea level Refer to the National Fuel Gas Code The unit and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa This is accomplished by closing the gas supply line valve The unit must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 9 psi 3 5 kPa When a gas appliance is for connection to a fixed piping system the installation must conform with local codes
3. 3 B Hand tighten then use two 3 4 open end wrenches or equivalent to fasten Installation continued on next page L Fig 15 1 Locate hearth Car Align left rear edge Hardware Bolts x 4 Nuts x 4 Washers x 8 Fig 15 3 Install left amp right firebox pieces FIREPLACE INSTALLATION cont 5 Place the inner rear panel in position against the rear of Hardware the fire box then fasten using a Phillips screwdriver and D 1 4 x 1 3 4 the supplied concrete screws see Fig 16 1 Faz pei Place the top panel as shown in Fig 16 2 no hardware required It should rest on top of the firebox pieces below use the tape found on the firebox pieces to properly locate Note Remove the tape after the top panel is located 7 Place the housing piece in position allowing enough space on the left side of the unit to make the gas connections see Fig 16 3 Place the burner assembly down into the opening found on the center of the hearth shelf see Fig 16 4 Route the flex connector attached directly to the key valve into the left side of the unit and up to the burner assembly then connect Tighten securely See Fig 16 5 Note For natural gas models this is the flex connector that DOES NOT have a regulator in line The flex connector that has a regulator in line is for connection to the gas supply
4. Ne jamais utiliser l appareil dans un espace clos tel qu une caravane tente voiture ou la maison REV 0 1502170745 d INSTALLATEUR CONSOMMATEUR Ces instructions DOIVENT tre maintenues avec cet appareil pour la future r f rence Important Lisez ces instructions soigneusement avant de commencer l installation de l unit AVERTISSEMENT L installation l ajustement le changement le service ou l entretien inexact peuvent causer des d gats mat riels le dommage corporel ou des pertes humaines Lisez l installation l op ration et les instructions d entretien compl tement avant d installer ou entretenir cet quipement Cet Appareil gaz est con u comme un appareil assist Les adultes doivent tre pr sents lorsque l appareil est en marche Ne laissez pas l appareil est en marche sans surveillance Si le produit est laiss br ler sans surveillance il peut causer des dommages ou des blessures graves IMPORTANT Pour un fonctionnement s r et une bonne performance de ce produit et de se conformer la certification les annonces et les acceptations du code du b timent utiliser uniquement des contr les Peterson AFD les pieces et accessoires qui ont t sp cifiquement num r s ou certifi es pour une utilisation avec ce foyer L utilisation d autres commandes pi ces ou accessoires est interdite et videra toutes les garanties certifications listes et approbations de cod
5. These instructions MUST be retained with this unit for future reference Important Read these instructions carefully before starting installation of the unit WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment This appliance is designed as an attended appliance Adults must be present when the unit is operating DO NOT leave the unit burning when unattended If the product is left burning unattended it may cause damage or serious injury IMPORTANT For safe operation and proper performance of this product and to comply with certification listings and building code acceptances use ONLY Peterson AFD controls parts and accessories that have been specifically listed or certified for use with this fireplace Use of other controls parts or accessories is prohibited and will void all warranties certifications listings and building code approvals and may cause property damage personal injury and loss of life CODE AND SUPPLY REQUIREMENTS The gas installation must conform with local codes and ordinances or in the absence of local codes with the latest National Fuel Gas Code ANSI 2223 1 Robert H Peterson Co 14724 East Proctor Avenue City of Industry CA 91746 REV 0 1502170745 L H
6. WARRANTY Robert H Peterson Co RHP warrants your American Fire Designs product to be free from defects in material and workmanship American Fyre Designs AFD exterior fireplaces BBQ islands fire tables fire urns fire pits Fire Falls Fire Walls gas logs and burner components products are warranted for THREE 3 YEARS All AFD valves electrical components and controls are warranted for ONE 1 YEAR excluding batteries This warranty does not apply to product damage caused by burning wood or any fuel other than natural gas or propane or damage or discoloration to product used in high wind conditions A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE IS REQUIRED This warranty applies to the original purchaser for products which are installed in the United States or Canada and which are operated and maintained as intended for single family residential usage This warranty is valid only with proof of purchase shall commence on the date of purchase and shall terminate both as to original and any replacement products on the anniversary date of the original purchase of the product stated on the above schedules This warranty covers defects in material and workmanship This warranty does not cover parts which become defective as a result of negligence misuse use not in compliance with the Owner s Manual Installation Instructions accidental damage improper handling improper storage improper installation lack of
7. above the burner when placing glass media Store any excess media in a safe location LAVA MEDIA Pour the lava granules or lava coals evenly into the burner pan see Fig 19 2 The media should be flush with the top of the pan DO NOT overfill Important DO NOT exceed a height of 1 2 above the burner when placing lava media Store any excess media in a safe location Fig 19 1 Glass option Lava coals shown Fig 19 2 Lava media option INSTRUCTIONS D ALLUMAGE MOD LE DE VANNE CL POUR VOTRE S CURIT LIRE AVANT D ALLUMER AVERTISSEMENT SIVOUS NE SUIVEZ PAS CES INSTRUCTIONS LA LETTRE UN INCENDIE OU UNE EXPLOSION POURRAIENT S ENSUIVRE CAUSANT DES DOMMAGES MATERIELS DES BLESSURES OU DES PERTES DE VIE AVANT D ALLUMER sentez tout autour de l unit de surface pour le gaz Assurez vous de sentir pr s du plancher car certains gaz sont plus lourds que l air et se d posent sur le sol QUE FAIRE SI UNE ODEUR DE GAZ 1 Coupez le gaz l appareil 2 teindre toute flamme nue 3 Si l odeur persiste appelez imm diatement votre fournisseur de gaz ou le service des incendies Utilisez uniquement une cl propre tourner la vanne de la conduite de gaz Ne jamais utiliser d outils Si la vanne ne tourne pas NE PAS essayer de le r parer Appelez un technicien de service qualifi Force ou une tentative de r paration pourrait provoquer un incendie ou une explosion 1 ARR T Lire les consign
8. burner on natural gas Ensure proper gas type The gas supply used may not be the same as that stated on the unit rating plate Shut down immediately to verify and if necessary contact your local dealer The unit may be converted to the gas type of the gas supply IF PERMITTED Flame lifts off the burner assembly Unit exposed to high wind conditions Ensure that the unit is installed in an area that is less susceptible to high wind conditions DO NOT operate in high wind conditions Flame height drops when unit is in operation Low gas pressure due to improper gas supply line Check gas supply line and gas pressure Read D E of PRE INSTALLATION AND PREPARATION SAFETY GUIDELINES section amp check with local gas company Burner lights but will not stay lit Low gas pressure Unit exposed to high wind conditions Clogged burner ports Faulty valve or regulator Check gas pressure Read D E of PRE INSTALLATION AND PREPARATION SAFETY GUIDELINES section amp check with local gas company Ensure that the unit is installed in an area that is less susceptible to high wind conditions Clean burner ports Contact a qualified professional service technician and the local dealer Burner flashback or flame burning out of orifice Clogged burner ports Clogged burner orifice Clean burner ports Clean burner orifice WARRANTY AMERICAN FYRE DESIGNS BY R H PETERSON CO LIMITED
9. gaz Fig 20 1 a y D vanne cl Fig 20 2 LIGHTING INSTRUCTIONS KEY VALVE MODELS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE BEFORE LIGHTING smell all around the unit area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS 1 Shut off the gas to the appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas supplier or the fire department Use only a proper key to turn the gas line valve Never use tools If the valve will not turn DO NOT try to repair it Call a qualified professional service technician Force or attempted repair may result in fire or explosion 1 STOP Read the safety information above Ensure the key valve is completely in the OFF position before beginning lighting sequence Lay a lighted long stem match on the surface of the decorative media near the burner do not hold the match in your hand or use a lighted long necked butane lighter Fig 21 1 Once the match is burning and in position slowly turn the key valve counter clockwise toward the ON position until it no longer rotates see Fig 21 2 Your Apply match then turn on gas burner should light T CAU
10. installing this unit Be sure you understand all safety precautions and warnings contained in this manual FOR OUTDOOR USE ONLY When shutting the unit down be sure to TURN THE CONTROL VALVE FULLY OFF WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH DO NOT MODIFY THIS unit OR ITS CONTROLS EXCEPT AS PROVIDED FOR IN THIS MANUAL Any other change may be dangerous Improper installation or use of the unit can cause serious injury or death from fire burns explosions or carbon monoxide poisoning Check state and local codes to determine if the unit is permitted in your locality before installation The manual valve allows for an adjustable flame height THESE SETTINGS MUST ALWAYS BE HIGH ENOUGH FOR THE FLAME TO BE CLEARLY VISIBLE WHEN LIGHTING THE UNIT ALWAYS LIGHT ON HIGH FIREPLACE INSTALLATION BEFORE YOU BEGIN Important Prior to installation ensure that all specifications dimensions and minimum clearances stated in this manual are observed You must read all warnings and safety information and understand all of the information in this manual All installation requirements must be observed and met WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this unit may result in property damage or personal injury e Confirm the installation site accommodates the fireplace per the requirements in this manual e Be sure the gas supply propan
11. or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 International Fuel Gas Code Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 as applicable INSTALLER NOTE This unit should be installed so that it can be removed if service is required GAS SUPPLY PLUMBING REQUIREMENTS Apply only joint compounds that are resistant to all gasses on all male pipe fittings Make sure to tighten every joint securely Do not use pipe joint compound to connect flare fittings Bring the gas supply pipe up from beneath the hearth or directly behind the hearth as appropriate for your installation CAUTION Installation and maintenance must be done by an NFI Certified or other qualified professional service technician Installer read these instructions before installing Be sure you understand all safety precautions and warnings contained in the manual Note An external on off valve in the gas line is optional for safety when the unit is not in use It also provides for convenient maintenance and repair INSTALLATION SAFETY GUIDELINES Installation and repair should be done by a qualified professional service technician The gas appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative that control compartment burners and circulating air passageways of the ap
12. place Route flex on key valve to burner Connect flex to burner Connect to gas supply leak test not shown Fig 14 1 Completely slide housing into Manhattan Overall position Orientation Install outer rear panel FIREPLACE INSTALLATION cont GAS SUPPLY SETUP if applicable For Natural or Household Propane Gas Supply The unit s valve is located on its left side The gas supply is to be brought up from beneath the hearth or directly behind it Your individual installation may vary Observe all local codes 1 Route the gas supply into the area that the fireplace hearth will rest over Important Locate the gas supply line out of pathways where people may trip over it or in areas where the line may way be subject to accidental damage if applicable FIREPLACE ASSEMBLY STEP BY STEP CAUTION Fireplace components are heavy CAREFULLY handle all components during assembly Hearth and Body Pieces 1 Locate the hearth piece in an appropriate location refer back to the LOCATION section if needed See Fig 15 1 Place the shelf piece on top of the hearth no hardware required The rear left corner of the shelf should rest flush with the hearth below See Fig 15 2 Place the left and right firebox pieces onto the shelf as shown in Fig 15 3 A Note Ensure the holes on the bottom of the pieces align with the holes on the top of the hearth 4 Insert the hardware kits in the order shown in Fig 15
13. side Ensure the plate is placed in the gap between the shelf and the hearth during installation To view simply reach in access then return once done See Fig 9 1 MINIMUM CLEARANCES TO COMBUSTIBLES The dimensions shown below are MINIMUM CLEARANCES to maintain when you install the unit ALL CLEARANCES AND INFORMATION STATED HERE MUST BE MAINTAINED AND FOLLOWED Description Dimension Side clearance 6 from hearth extension to combustible construction Clearance above unit Not permitted Clearance below unit 0 Front clearance 36 from hearth extension to combustible construction Rear clearance 6 Table 4 Minimum Clearances to Combustibles gt C Floor must be a hard level surface Combustible materials permitted TOOLS REQUIRED The following are the minimum tools required for the installation of your fireplace Additional tools may be required for your individual installation 2 man or more crew recommended e Phillips screwdriver appropriate tools for gas supply e 3 4 open end wrenches 2 install or equivalent cordless drill e drill bits and drivers PARTS LIST In addition to the Replacement Parts List wr DD D D reference the Identification Parts List IMPORTANT 6 COMPONENTS 9 Your fireplace is packaged onto 1 pallet Remove all packing 9 Decorative media is purchased and packaged material including ARE HEAVY id separately Various st
14. 2 016 AMERICAN F RE DESIGNS INSTALLATION ET MODE D EMPLOI by R H Peterson co 082 S rie We recommend that our gas hearth products be installed and serviced by profes sionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists AVERTISSEMENT Pour l usage ext rieur seulement MANHATTAN CHEMIN ES D EXT RIEUR AVERTISSEMENT Si l information en ce manuel n est pas suivie exactement une incendie ou une explosion peut r sulter entra nant des d gats mat riels le dommage corporel ou des pertes humaines Ne pas entreposer ni utiliser d essence ou d autres vapeurs et liquides inflammables proximit de cet appareil ou de tout autre Une bouteille de propane non branch e ne doit pas tre entrepos e proximit de cet ou tout autre appareil DANGER Si vous sentez une odeur de gaz 1 Coupez le gaz l appareil 2 teindre toute flamme nue 3 Si l odeur persiste loignez vous de l appareil et appelez imm diatement votre fournisseur de gaz ou les pompiers L installation et le service doivent tre assur s par un NFI certifi ou toute autre installateur agence de service ou fournisseur professionnelle qualifi e de gaz DANGER CARBON MONOXIDE HAZARD Un foyer gaz ventil peut produire du monoxyde de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer
15. 5 7 cm high Cylinders must be constructed and marked in accordance with the Specifications for Propane Gas Cylinders of the U S Department of Transportation D O T or the National Standard of Canada CAN CSA B339 Cylinders Spheres and Tubes for Transportation of Dangerous Goods The cylinder used must include a collar to protect the cylinder valve and the cylinder supply system must be arranged for vapor withdrawal The pressure regulator and hose assembly Fig 7 1 supplied with this outdoor gas appliance L P models only must be used Original and replacement pressure regulator and hose assemblies must be those specified by the manufacturer for connection with a cylinder connecting device identified as Type by the ANS Z 21 58 2005 CGA 1 6 2005 see PARTS LIST for ordering information The propane gas cylinder valve must be equipped with a cylinder connection coupling device described as Type in the standard defined in paragraph e above This device is commonly described as an Acme thread quick coupler If the propane gas cylinder comes with a dust plug place the dust cap on the cylinder valve outlet whenever the cylinder is not in use QUICK COUPLER OPERATION To connect the regulator hose assembly to the propane gas cylinder valve fitting Press the hand nut on the regulator over the Acme thread fitting on the cylinder valve Turn the hand nut clockwise to engage the threads and tighten until snug The us
16. CAUSANT LA MORT OU DES DOMMAGES SERIEUX PEUT SE PRODUIRE Fig 6 1 type coupleur rapide de fil de point culminant d l Ajustage de pr cision en laiton de fil de 4 point culminant Volant de commande EE i R gulateur ndicateur de niveau de liquide facultatif AAAAAAAAAAA d compression a Ecrou de main avec le fil de point culminant n Passage SAFE USE amp MAINTENANCE OF PROPANE GAS CYLINDERS IMPORTANT FOR YOUR SAFETY READ AND FOLLOW ALL WARNINGS PROVIDED WITH THE PROPANE GAS CYLINDER When operating this appliance with a propane gas cylinder these instructions and warnings MUST be observed FAILURE TO DO SO MAY RESULT IN A SERIOUS FIRE OR EXPLOSION CYLINDER CONNECTOR REQUIREMENTS a Propane gas cylinders valves and hoses must be maintained in good condition and must be replaced if there is visible damage to either the cylinder or valve If the hose is cut or shows excessive abrasion or wear it must be replaced before using the gas appliance see e This unit when used with a cylinder should be connected to a standard 5 gallon 20 Ib propane gas cylinder equipped with an OPD Overfill Prevention Device The OPD has been required on all cylinders sold since October 1 1998 to prevent overfilling Cylinder dimensions should be approximately 12 30 5 cm in diameter and 18 4
17. ION cont Final Assembly Steps 1 Once gas connection is complete carefully slide the housing piece into position see Fig 18 1 Place the outer rear panel in position against the rear of the fire box then fasten using a Phillips screwdriver and the supplied concrete screws see Fig 18 2 Fig 18 1 Slide housing into position lt Fig 18 2 Install outer rear panel DECORATIVE MEDIA PLACEMENT WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury CAUTION Be sure the unit and the decorative media are completely cool anytime the media is handled Wear gloves whenever installing and handling as certain media may have sharp edges that can cause personal injury This unit has several options for decorative media The decorative media is purchased and packaged separately Contact your local American Fyre Designs dealer for ordering information Locate the section below that applies to your option chosen and install accordingly Reference the SPECIFICATIONS AND DIMENSIONS section for details on the recommended amounts of media GLASS MEDIA Pour the glass media glass gems nuggets evenly into the burner pan see Fig 19 1 The media should be flush with the top of the pan DO NOT overfill Important DO NOT exceed a height of 1 2
18. NQUE DE FAIRE AINSI PEUT AVOIR COMME CONSEQUENCE UNE INCENDIE OU UNE EXPLOSION SERIEUSE CYLINDRE ET CONDITIONS ET CARACTERISTIQUES DE CONNECTEUR a Des cylindres et les valves de gaz de propane doivent tre maintenus en bon tat et doivent tre remplac s s il y a des dommages vidents au cylindre ou la valve Ce gril une fois utilis avec un cylindre devrait tre reli un gallon de la norme 5 201b cylindre de gaz de propane quip d un OPD remplissez au dessus du niveau le dispositif d emp chement LOPD a t exig sur tous les cylindres vendus depuis octobre 1 1998 pour emp cher le remplissage excessif Les dimensions de cylindre devraient tre approximativement 12 30 5cm de diam tre et 18 45 7cm hauts Des cylindres doivent tre construits et marqu s selon les caract ristiques pour des cylindres de gaz de propane du d partement des ETATS UNIS du transport D O T ou le niveau national du Canada du CAN CSA B339 des cylindres des sph res et des tubes pour le transport des marchandises dangereuses Le cylindre doit inclure un collier pour prot ger la valve de cylindre et le circuit d alimentation de cylindre doit tre assur le retrait de vapeur Le montage du r gulateur de pression et le flexible Fig 6 1 fourni avec cet appareil au gaz en plein air mod les au propane seulement doit tre utilis Assembl es d origine et r gulateur de pression et le tuyau de remplacement doiv
19. OUS INJURY MAY OCCUR Fig 7 1 Type Acme thread quick coupler acc Hand wheel Type 1 valve F5 lt ein 5 relief Ca valve Liquid level indicator optional Brass Acme thread fitting Regulator AAAAAAAAAA Hand nut with Acme thread wa SPECIFICATIONS AND DIMENSIONS Fireplace Style BTUs Nat L P Dimensions Weight Pieces Manhattan Fireplace 082 45 000 40 000 59 w x 32 d x 42 h 750 lbs 8 pcs Table 1 Overall Product Dimensions TK or ss SPECIFICATIONS AND DIMENSIONS cont Follow the recommendations below for decorative media amounts All decorative media options are purchased separately Contact your local American Fyre Designs dealer when ordering When using lava media Recommended Amount of Lava Media Lava Granules Option Lava Coals Option Manhattan 3 Ibs 3 Ibs Table 2 Lava Recommendations Fireplace Style When using glass media Fireplace Style Recommended Amount of Glass Manhattan 6 lbs Table 3 Glass Recommendations View from beneath left side of shelf Fig 9 1 Marking label plate location 4 The unit s marking label plate is located under the shelf It hangs from a chain on the front inner wall valve
20. Performing these procedures will ensure proper operation appearance and safety WEAR GLOVES If maintenance is required it must be done by a qualified professional service technician Always shut off the gas to the unit while performing service work Allow the unit to cool before servicing The entire burner system should be inspected regularly Excessive debris can build up on the unit from leaves dirt or other debris It is critical that all control components burners vent openings and the surrounding area be kept clean and free of all obstructions Examine that all components are properly assembled installed as instructed in this manual Ensure that all decorative media is properly placed as instructed in this manual The burner assembly must be replaced prior to the unit being put into operation if it is evident that the burner is damaged Contact your local dealer for replacement parts DO NOT use substitute materials when replacing any components of the appliance Keep the vent openings and surrounding area of the of the unit clean and free of obstructions at all times Periodically perform visual checks of the burner flames The burner flames should be blue at the base with a combination of blue yellow at the body and tips Contact a qualified professional service technician for maintenance To maintain the concrete components see the CONCRETE CARE section for details Any guard or other protective device removed for ser
21. TION If the burner does not light before the match Fig 21 1 goes out immediately turn the key valve clockwise toward the OFF position until it no longer rotates Wait approximately five 5 minutes to clear out any gas and repeat steps 1 4 above If your burner fails to light again turn the key valve clockwise toward the OFF position until it no longer rotates and contact your dealer or gas supplier TO SHUT OFF GAS TO THE APPLIANCE To extinguish your gas burner insert the key into the key Key valve valve and turn the valve clockwise toward the OFF position Fig 21 2 until it no longer rotates see Fig 21 2 Be sure the control knob is turned fully off to avoid any gas leakage SERVICING AND CLEANING Each installation site for any unit presents its own unique combustion environment Specific factors such as weather wind currents yard debris altitude drafts the size of the surrounding area all have an influence on the proper operation of the gas appliance A normally operating appliance will demonstrate the following characteristics e A lively realistic yellow flame e Odor free If the flame is not clean identifiable by excessive sooting on the decorative media refer to the information below Some soot on the media may occur and should not be a concern unless excessive ANNUAL CLEAN INSPECTION GUIDELINES The unit and the installation must be inspected annually Refer to these instructions for details
22. ally the same and the finish will vary FUEL CONVERSION KITS A certified kit is available from the manufacturer to convert your appliance from natural gas to L P or vice versa Contact your dealer for ordering information Follow the instructions provided with the kit when converting NOTES PAGE Please use this page to record any information that you may want to have at hand TROUBLESHOOTING If you have trouble with your unit please use this list to identify the problem By trying one or more of the solutions to the probable cause you should be able to solve the problem If this list does not address your present problem or if you have other technical difficulties with your unit please contact your local dealer or visit our web site at www rhpeterson com SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Burner will not turn on Gas not reaching appliance Air in gas line Check gas supply and gas shut off valve Purge air from gas line Unit overheating or poor combustion Vent openings surrounding area blocked with debris Clean vent openings and surrounding area of all obstructions Low flame Low gas pressure Propane tank running low if applicable Check gas pressure Read D E of PRE INSTALLATION AND PREPARATION SAFETY GUIDELINES section amp check with local gas company Fill tank completely Low flame or too high flame Using natural gas burner on propane gas or propane
23. combustible materials gasoline and other flammable vapors and liquids There is no blockage of the airflow through the vent openings located on the unit Thehose is inspected if applicable See the SAFE USE amp MAINTENANCE OF PROPANE GAS CYLINDERS section WARNING HOT WHILE IN OPERATION AND FOLLOWING OPERATION Serious injury can occur DO NOT throw trash paper or other flammable materials into the unit DO NOT leave in operation when unattended WARNING DO NOT operate this unit in the rain WARNING DO NOT operate this unit in high wind conditions DO NOT continue using if you smell unusual odors or have headaches nausea or dizziness DO NOT store any combustible materials gasoline and any other flammable vapors liquids in the vicinity of the unit Provide adequate clearance for servicing and operation Matches paper garbage or any other material must not be thrown into the unit K DO NOT use the appliance if any part of it has been underwater Immediately call a qualified professional service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater UTILISATION SURE ET ENTRETIEN DES CYLINDRES DE GAZ DE PROPANE IMPORTANT POUR VOTRE SURETE LISEZ ET SUIVEZ TOUS LES AVERTISSEMENTS EQUIPES DE VOTRE CYLINDRE DE GAZ DE PROPANE En actionnant cet appareil avec un cylindre de gaz de propane ON DOIT observer ces instructions et avertissements LE MA
24. e done To Connect to a Natural or Household Propane Gas Supply 1 Locate the flex connector that is already installed on the rear of the valve assembly Locate the gas supply that is beneath or behind the hearth previously routed at beginning of installation Install the supplied flare adapter to the gas supply NPT using a gas pipe sealing compound or Teflon tape see Fig 17 4 Connect the flex connector to the flare adapter see Fig 17 4 Leak Test Turn on the gas supply ignite the burner and test at all connections for leaks using a soapy water solution If bubbles appear a leak is present Turn off the gas and tighten at all connections Repeat until no leaks are present If a leak persists turn off the gas supply and contact the local gas company or dealer NEVER USE A FLAME TO CHECK FOR LEAKS Installation continued on next page L P Regulator Hose Assembly or flex connector S Storage Door L P models only K Fig 17 1 Gas connections detail Propane cylinder AAAAAAAAAAA Regulator hose assy coming from valve assy x 2 Fig 17 2 Connecting to an L P cylinder FT Fig 17 3 L P Cylinder placement UUU Flex connector coming from valve assy UCL y UD A Flare adaptor v a Gas supply Fig 17 4 Connecting to a gas line A FIREPLACE INSTALLAT
25. e of pliers or a wrench should not be necessary Only cylinders marked propane may be used To disconnect Turn the hand nut counterclockwise until detached Fig 7 1 Important Before using the unit and after each time the cylinder is removed and reattached check the hose for wear see a and check all connections for leaks Turn off the unit valves and open the main cylinder valve then check connections with soapy water Repair any leaks before lighting the unit CAUTION Always turn the propane cylinder main valve off after each use and before moving the unit and cylinder or disconnecting the coupling This valve must remain closed and the cylinder disconnected while the appliance is not in use even though the gas flow is stopped by a safety feature when the coupler is disconnected Carefully inspect the hose assembly each time before the gas is turned on A cracked or frayed hose must be replaced immediately If the appliance is stored indoors the cylinder must be disconnected and removed Disconnected cylinders must be stored outdoors out of the reach of children with threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area FOR YOUR SAFETY a DO NOT store a spare propane gas cylinder under or near this appliance b NEVER fill the cylinder beyond 80 percent full IF THE INFORMATION IN a AND b IS NOT FOLLOWED EXACTLY A FIRE CAUSING DEATH OR SERI
26. e or natural is turned off at its source e Wear gloves and use extreme caution whenever installing and handling this product and its accessories as certain components have sharp edges that can cause personal injury e Remove all packing material including any protective coatings and discard prior to installation LOCATION While following all requirements and safety information in this manual see MINIMUM CLEARANCES TO COMBUSTIBLES section determine and prepare the location of the fireplace a hard and level surface Note For fireplaces a combustible surface is permitted Important The gas supply must be considered when determining the location of the unit See GAS SUPPLY SETUP section for details if applicable ASSEMBLY REQUIRES TWO OR MORE PEOPLE EXERCISE EXTREME CARE DURING ASSEMBLY AND INSTALLATION FIREPLACE INSTALLATION cont FIREPLACE ASSEMBLY OVERVIEW CAUTION Fireplace components are heavy CAREFULLY handle all components during assembly e Fig 14 1 provides an overall orientation and assembly detail for the Manhattan fireplace e This section is just an overview refer to the following step by step section for complete assembly and installation details ASSEMBLY INSTALL OVERVIEW Route gas supply if applicable Place hearth Place shelf Install left and right firebox pieces Install inner rear panel Place top panel Position housing allow space for gas connections Drop burner in
27. ent tre ceux sp cifi s par le fabricant pour le raccordement d un dispositif de cylindre de liaison identifi e comme de type par le 21 58 2005 CGA ANSI Z 1 6 2005 voir liste des pi ces pour les informations de commande La valve de cylindre de gaz de propane doit tre quip e d un dispositif d accouplement de raccordement de cylindre d crit comme type dans la norme d finie dans le e de paragraphe ci dessus Ce dispositif est g n ralement d crit comme coupleur rapide de fil de point culminant Si votre cylindre de gaz de propane vient avec une prise de la poussi re placez le bouchon anti poussi re sur la sortie de valve de cylindre toutes les fois que le cylindre n est pas en service OP RATION DE COUPLEUR RAPIDE Pour relier le regulator hose l ajustage de pr cision de valve de cylindre de gaz de propane Serrez l crou de main sur le r gulateur au dessus de l ajustage de pr cision de fil de point culminant sur la valve de cylindre Tournez l crou de main dans le sens des aiguilles d une montre pour engager les fils et pour serrer jusqu ce que douillettement L utilisation des pinces ou de la cl ne devrait pas tre n cessaire Seulement le propane marqu par cylindres doit tre employ Pour d brancher Tournez l crou de main dans le sens contraire des aiguilles d une montre jusqu isol fig 6 1 Important Avant d employer le gril et ensuite chaque fois que
28. es de s curit ci dessus S assurer que le robinet est compl tement cl en position OFF TEINDRE avant de s quence d clairage partir Poser une allumettes tige longue clair sur la surface des m dias d coratifs pr s du br leur ne pas tenir le match en main ou utiliser un briquet au butane long cou clair Fig 20 1 Une fois que le match est en feu et en position tourner lentement la vanne cl dans le sens antihoraire vers la position ON allumer jusqu ce qu il ne tourne plus voir Fig 20 2 Votre br leur devrait s allumer ATTENTION Sile br leur ne s allume pas avant le match s teint tournez imm diatement le vanne cl dans le sens horaire vers la position OFF TEINDRE jusqu ce qu il ne tourne plus Attendez environ cinq 5 minutes pour laisser chapper tout le gaz et r p tez les tapes 1 4 ci dessus Si votre graveur ne s allume nouveau tourner le vanne cl dans le sens horaire vers la position OFF ETEINDRE jusqu ce qu il ne tourne plus et contactez votre revendeur ou fournisseur de gaz POUR ARR TER LE GAZ L APPAREIL Pour teindre votre br leur gaz ins rez la cl dans la valve touche et tournez la valve dans le sens horaire vers la position d arr t jusqu ce qu il ne tourne plus voir Fig 20 2 Assurez vous que le bouton de commande esttourn fond au large pour viter toute fuite de gaz wae N NAppliquer match puis tourner sur le
29. es du b timent et peut causer des d gats mat riels le dommage corporel et des pertes humaines CONDITIONS DE CODE ET D APPROVISIONNEMENT L installation de gaz doit se conformer aux codes locaux et aux ordonnances ou en l absence des codes locaux au plus d funt code national de gaz de carburant la norme ANSI 2223 1 L H2 016 TABLE OF CONTENTS GETTING STARTED PRE INSTALLATION AND PREPARATION SAFETY GUIDELINES INSTALLATION SAFETY GUIDELINES OPERATING THE UNIT SAFELY AND CORRECTLY SAFE USE amp MAINTENANCE OF PROPANE GAS CYLINDERS SPECIFICATIONS AND DIMENSIONS MINIMUM CLEARANCES TO COMBUSTIBLES TOOLS REQUIRED PARTS LIST INSTALLATION IMPORTANT SAFETY INFORMATION FIREPLACE INSTALLATION BEFORE YOU BEGIN LOCATION FIREPLACE ASSEMBLY OVERVIEW GAS SUPPLY SETUP if applicable FIREPLACE ASSEMBLY STEP BY STEP DECORATIVE MEDIA PLACEMENT GLASS MEDIA LAVA MEDIA USE CARE amp SERVICE LIGHTING INSTRUCTIONS KEY VALVE MODELS FOR YOUR SAFETY READ BEFORE LIGHTING TO SHUT OFF GAS TO THE APPLIANCE SERVICING AND CLEANING ANNUAL CLEAN INSPECTION GUIDELINES CONCRETE CARE FUEL CONVERSION KITS NOTES PAGE TROUBLESHOOTING WARRANTY IMPORTANT SAFETY INFORMATION Congratulations on your purchase of an American Fyre Designs outdoor gas fireplace Made with pride in America your new fireplace complies with national safety standards and when installed per these instructions and used as intended it will provide warmth and co
30. f AMERICAN F RE DESIGNS INSTALLATION amp OWNER S MANUAL by RH Peterson co 082 Series NATIONAL NATIONAL We recommend that our gas INSTITUTE hearth products be installed NTSB and service d by profes sionals who are certified in the U S by the National Fireplace Institute NFI as CERTIFIED NFI Gas Specialists AAWARNING For Outdoor Use Only MANHATTAN OUTDOOR FIREPLACE WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance A propane cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department Installation and service must be performed by an NFI Certified or other qualified professional installer service agency or gas supplier DANGER CARBON MONOXIDE HAZARD A vented gas appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use the appliance in an enclosed space such as a camper tent car or home INSTALLER amp CONSUMER
31. le cylindre est enlev et rattach examinez tous les raccordements pour d celer les fuites Arr tez les valves de gril et ouvrez la valve principale de cylindre puis v rifiez les raccordements avec de l eau savonneux R parez toutes les fuites avant d allumer le gril ATTENTION Tournez toujours la valve principale de cylindre de propane au loin apr s chaque utilisation et avant de d placer le gril et le cylindre ou d brancher l accouplement Cette valve doit rester ferm e et le cylindre a d branch alors que l appareil n est pas en service quoique l coulement de gaz soit arr t par un dispositif de s ret quand le coupleur est d branch Inspectez soigneusement l ensemble de tuyau chaque fois avant que le gaz soit allum Un tuyau fissur ou effiloch doit tre imm diatement remplac Si l appareil est stock l int rieur le cylindre doit tre disconnected et a enlev Des cylindres Disconnected doivent tre stock s dehors hors de la port e des enfants avec les prises de valve filet es troitement install es et ne doivent pas tre stock s dans un b timent le garage ou n importe quel autre secteur inclus POUR VOTRE SURETE a Ne stockez pas un cylindre de gaz disponible de propane dessous ou ne vous approchez pas de cet appareil b Ne remplissez jamais cylindre au del de 80 pour cent de plein c SI LINFORMATION DANS A ET B N EST PAS SUIVIE EXACTEMENT UN FEU
32. mfort to your outdoor area for many years Prior to installation and operation ensure that all specifications dimensions and minimum clearances stated in this manual are observed You must read all warnings and safety information and understand all of the information in this manual All installation requirements must be observed and met REV 0 1502170745 3 L H2 016 PRE INSTALLATION AND PREPARATION SAFETY GUIDELINES Before installing this unit check the MINIMUM CLEARANCE TO COMBUSTIBLES section to ensure that the surrounding area is properly sized for the installation The unit is for outdoor use only DO NOT install or use this appliance inside a building garage or any other enclosed area including recreational vehicles and or boats THIS UNIT MUST BE INSTALLED IN SUCH A MANNERTHAT ALL VENT OPENINGS ONTHE UNIT REMAIN CLEAR AND FREE OF ALL OBSTRUCTIONS AT ALL TIMES AND DURING ALL WEATHER CONDITIONS SOLID FUEL MUST NOT BE BURNED in the unit CHECK GAS TYPE natural gas or propane The gas supply you intend to use may not be the same as that stated on the burner rating plate as purchased If the gas supply is different convert the unit to the gas type you intend to use IF PERMITTED See the FUEL CONVERSION KIT section and contact the dealer for assistance FOR NATURAL GAS The minimum inlet gas supply pressure for purposes of input adjustment is 5 water column w c and the maximum inlet gas supply pressure is
33. not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specified legal rights and you may have other rights that vary from state to state or province For additional information regarding this warranty or to place a warranty claim contact the R H Peterson dealer where the product was purchased TO REGISTER YOUR PRODUCT ONLINE GOTO WWW RHPETERSON COM AND CLICK ON PRODUCT REGISTRATION THANK YOU FOR YOUR PURCHASE Quality Check Burner Orifice Nat L P Leak Test Model Main Burn Test Serial Gas Type _Nat L P Inspector Robert H Peterson Co 14724 East Proctor Avenue e City of Industry CA 91746
34. pliance are kept clean Carefully inspect for shipping damage If any parts are damaged call the dealer Correct installation and proper placement of the unit and its decorative media is crucial to the safe performance of the unit See installation instructions for further information DO NOT install the unit under any overhead combustible materials Ensure that the unit is installed on a hard and level surface Ensure that the unit is installed in such a manner that all vent openings on the unit remain clear and free of all obstructions at all times and during all weather conditions Due to high temperatures the unit must be located out of traffic areas and away from combustibles OPERATING THE UNIT SAFELY AND CORRECTLY This product is a decorative gas appliance It is not a cooking appliance SOLID FUEL MUST NOT BE BURNED in the unit When shutting the appliance down be sure to TURN THE CONTROL VALVE FULLY OFF Children MUST be carefully supervised when they are in the area of this unit DO NOT sit or place any part of the body clothing or other flammable materials on or near the unit surround Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition DO NOT lean into the unit when lighting or when in use Every time you use the unit make sure that The area around the unit is clear and free from
35. required routine maintenance as specified in the Owner s Manual Installation Instructions electrical damage local gas impurities or failure to protect against combustibles Product must be installed and gas must be connected as specified in the Owner s Manual Installation Instructions by a qualified professional installer Modifications to products which are not specifically authorized will void this warranty Accessories parts valves remotes etc when used must be Peterson products or this warranty is void Warrantied items will be repaired or replaced at Peterson s sole discretion This warranty does not apply to rust corrosion oxidation or discoloration unless the affected part becomes inoperable This warranty does not cover labor or labor related charges except as provided by separate specific written programs from the Peterson Co All repair work must be performed by a qualified professional service person and requires prior approval of Peterson Peterson may require the defective product or part to be returned to the factory to determine the cause of failure Peterson will pay freight charges if the product or part is determined to be defective This warranty does not cover breakage in shipment from our Independent distributor to its customer if the damage is determined to have occurred during that shipment This warranty specifically excludes liability for indirect incidental or consequential damages Some states and provinces do
36. vicing the unit shall be replaced prior to operating the unit Verify proper operation after servicing CAUTION HOT DURING OPERATION AND AFTER USE Children must be supervised when in the vicinity of this unit Serious injury may occur Children must be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition SERVICING AND CLEANING cont CONCRETE CARE As with any surface concrete components require regular maintenance and care Certain guidelines must be followed to preserve the concrete s appearance and structural integrity Scratches may occur due to usage To minimize avoid striking or dragging heavy rough or sharp objects across the unit Spotting and hairline cracks may occur due to nature of product and are not considered a manufacturing defect Concrete products are porous and susceptible to discoloration from liquids especially oils and acidic substances During use clean up any spills immediately to prevent any possible staining or damage to the finish Avoid allowing water or any liquid substance to stand on the surface To clean the concrete first wash with a mild soap and water solution For stubborn stains a vinyl brush may be used Allow to dry Annually follow up with a masonry sealer in order to preserve the finish It should be noted that like natural stone concrete products will develop a patina when left outside No two concrete products are identic
37. yles are available any protective HANDLE WITH CARE Decorative media and replacement parts can coatings ana be ordered from your local American Fyre SCA prior to use II IIIA Designs dealer Select models are illustrated your model may vary REPLACEMENT PARTS LIST Description Part No Qty 18 linear straight burner only Nat OCBT 18 18 linear straight burner only L P OCBT 18P Rectangular burner pan only OCT 18 Key valve including key AV 30 Key only VK 1 Pressure regulator Nat only PR 4 Flex connector Nat only 3037 L P regulator and hose assembly L P only not shown PARTS LIST cont Description 10 Hil Hearth Shelf Firebox Left Firebox Right Inner rear panel Top panel Outer rear panel Housing Natural gas model Housing w door L P gas model Storage door L P only Hardware kit t Concrete Phillips screw 1 4 x 1 3 4 AR So 2 So a PS e eS oe not shown t each kit contains 1 1 2 13 x 3 5 bolt 1 nut 2 washers IDENTIFICATION PARTS LIST Manhattan 082 L P model shown IMPORTANT SAFETY INFORMATION BE CAREFUL If not installed and used correctly per these instructions this product can cause serious injury CAUTION Installation and maintenance must be done by an NFI Certified or other qualified professional service technician Read these instructions before
Download Pdf Manuals