1. FARO S p A Via Faro n 15 The manufacture 20060 Ornago Milano ITALY dichiara sotto la propria responsabilit che il prodotto declares under it s own responsibility that the product Designazione del prodotto Lampada polimerizzante Product s designation Composite cure light Modello POLILED COMPACT Model POLILED COMPACT E nuovo di fabbrica secondo quanto previsto dall articolo 6 par 2 del D L 626 94 It is newly manufactured in accordance with art 6 par 2 of Italian law D L n 626 94 E conforme alle seguenti Direttive europee ed ai rispettivi recepimenti nazionali e modifiche successive It complies with the following European Directives and their implementations into national laws and subsequent modifications 93 42 CEE direttiva dispositivi medici 93 42 EEC Medical Device Directive Classe di appartenenza dell apparecchio I a E conforme alle seguenti norme tecniche CEI EN 60601 1 CEI EN 60601 1 2 It complies with the following technichal standards CEI EN 60601 1 CEI EN 60601 1 2 Dott Angelo Favonio Amministratore Delegato Managing Director La presente una riproduzione conforme all originale che archiviato presso il fabbricante con i relativi numeri di serie This is a true copy The original is placed on manufacturer s files with the relative serial numbers DESCRIZIONE DELLE PARTI DESCRIPTION OF PARTS DESCRIPTIONS DES PARTIES TEILEBESCHREIBUNG DESCRIPCION DE LAS P
2. Schutzma nahmen ergreifen e Patienten die mit photosensiblen Farmaka behandelt werden nicht mit dem Ger t behandeln e Das Ger t ist nicht gegen Eindringen von Wasser gesch tzt e Das Ger t ist nicht geeignet in Gegenwart von in der Luft brennbaren Bet ubungsmitteln von Sauerstoff bzw Stickstoff Protoxyd Mischungen e Bei ausgedientem Ger t m ssen die einzelnen Teile gem Gesetzesvorschrift je nach Material Plastik Metall sowie elektronischer Kreislauf f r die Abfallversorgung getrennt gelagert werden e Nur die im vorliegenden Handbuch angezeigten Vorg nge ausf hren ansonsten den Technischen Hilfsdienst heranziehen FARO S p A verweigert jegliche Verantwortung f r direkte oder indirekte Sch den an Personen oder Gegenst nden in folgenden F llen 1 Das Ger t wurde nicht zweckbestimmt verwendet 2 Das Ger t wurde nicht nach den gesetzlichen Normen und der entsprechenden Beschreibung installiert 3 Das Ger t wurde nicht entsprechend den Anweisungen und Vorschriften im vorliegenden Handbuch benutzt 4 Das Ger t wurde von Personal das nicht von der FARO bestimmt wurde abge ndert bzw repariert TECHNISCHE EIGENSCHAFTEN e Das Poliled Ger t wird auf dem zahn rztlichen Gebiet als Polymerisierer von lichth rtenden Zahnmaterialien verwendet e Als Lichtquelle kommt eine einfarbig blaue hocheffiziente LED Diode zum Einsatz e Die ausgestrahlte Wellenl nge bewegt sich zwischen 440 und 480 nm e F
3. before using again The surface of the instrument has heated up e You have performed many cycles Let the instrument rest e If the problem continues disconnect the instrument from the cord and cool it them reconnect it If the instruments heats up again without being used completely disconnect it and apply to Service Department TECHNICAL PARTICULARS Application Polymerization or photohardening of dental materials Input voltage Vac 17 26 19 34 50 HZ Consumption VA 11 5 Protection level against direct and indirect contact device type B Wavelength 440nm to 480nm Protection against electric danger device class II Dimensions of instrument Length 165mm Cable fixed with the instrument Optical Fiber dia 8 autoclavable at 134 C Maximum dia 27mm Applicable standards EN 60601 1 and 60601 1 2 Weight 110g Light source One 5W LED with optical concentrator Working time Standard cycle at full power seconds 20 Ramp cycle from zero to full power seconds 10 Ramp power at full power seconds 10 Acoustic Signals Start and after every 10 seconds This equipment while in its transportation storage packing can withstand the following environmental conditions for a period of 15 weeks at most Surrounding temperature from 20 C to 70 C Relative humidity from 10 to 90 Atmospheric pressure from 500 to 1060 mbar X Disposal container Dispose the device observing the standards about the d
4. down to the striker CLEANING To clean the Lamp proceed as follows e Turn off the Main Power Switch before cleaning e Use a soft cloth slightly moistened with alcohol or similar detergent while being careful not to allow alcohol to run inside the equipment O Si E O a5 D Si A 2 O Si Q yo Sion A e Any residual reconstruction material encrusted on the Optical Fiber or the Lamp Body must be removed with beveled plastic tools e To get highest output always clean both sides of the Optical Fiber with a soft cloth every day Both sides of the Optical Fiber must be cleaned before each sterilization e Periodically examine the condition of the Optical Fiber Its surface should appear smooth uniform and free of halos or spots Any irregularities have a detrimental effect on polymerization TROUBLESHOOTING The Polymerizing Lamp does not light e Make sure electric power cord is correctly plugged in e Ifthe problem continues call on our Service Department Polymerization power is slight e Check condition and cleanliness of Optical Fiber and change if necessary e Ifthe problem continues call on our Service Department Optical Fiber is lost or broken e To find apply only to FARO Service centers Polymerizing Lamp shuts off too soon emits three beeps and stops further cycles e The Thermal Protection has operated Wait a few minutes
5. llt ist und den Stempel des Wiederverk ufers tr gt Mit dem Garantiezertifikat ist eine Reparatur w hrend der G ltigkeitsdauer der Garantie nur dann m glich wenn dem Ger t der Lieferschein bzw die Verkaufsrechnung beiliegt Die Garantie erstreckesich auf Sch den die durch Materialfehler bzw Fabrikations defekte entstanden Bei begr ndeter Beanstandung erfolgt die kostenlose Reparatur bzw Ersatz Einschadenersatz in Geld bzw von Zinsen ist augeschlossen Die Garantie ist nicht g ltig wenn der Ger t auf unanfechtbares Urteil der Hauses FARO hin abge ndert besch digt schlecht gewartet oder unsachgem CERTIFICADO DE GARANTIA FARO otorga al Cliente final una garantia de 24 meses contados a partir de la fecha de la factura de compra La reparaci n bajo garantia tendr que realizarse exclusivamente en FARO o en el establecimiento del Servicio de Asistencia autorizado FARO los gastos y riesgos del transporte est n a cargo del comprador El certificado de garanti que se encuentra en la anteportada del presente manual es v lido s lo si est rellenado en todas sus partes y lleva el sello del revendedor EI certificado permite la reparaci n bajo garanti durante el periodo de validez nicamente si acompa a el art culo a reparar junto con el albar n o factura de venta La garanti cubre las averi s debidas a la mala calidad del material o defectos de fabricaci n en caso de reclamos motivados la garanti permitir la repa
6. von 20 C bis 70 C Relative Luftfeuchtigkeit von 10 bis 90 gt Atmosph Druck von 500 bis 1060 mBar X Entsorgungsbeh lter Das Ger t unter Beachtung der Vorschriften f r die M lltrennung von elektrischem Material entsorgen MEDIDAS DE SEGURIDAD Siga todas las indicaciones contenidas en el presente manual e El dispositivo sirve para polimerizar las resinas compuestas fotoendurecedoras con fotoiniciador activable en una banda de longitud comprendida entre 440 y 480 nm en odontolog a utilizado en una consulta exclusivamente por el personal m dico INSTALLATION Make sure the following components are in the package Poliled Cord Installation Manual SPECIALIZED TECHNICIANS MUST INSTALL THIS DEVICE POWER MUST BE DISCONNECTED WHEN INSTALLING e Fasten the Power Cord inside the Chair using the Tearproof Cord so that a pull on the Cord will not cause traction on the power cord e Connect the Power cords only to a very low voltage safety transformer see Safety Instructions OPERATING INSTRUCTIONS The Poliled Polymerizing Lamp has two different types of exposition as follows e Cycle Power 20 second exposition cycle at full power e Soft Ramp Cycle 20 second exposition cycle with gradual increase in light intensity for first 10 second and up to full power USINGAT FULL CYCLE POWER e Press button 3 shortly LED goes on full power for 20 seconds e A s
7. 24 mesi months mois monaten meses nome name nom vorname nombre cognome surname prenom nachname apellido indirizzo address adresse auschrift direccion citt town ville ort ciudad data d acquisto purchase date date d achat SN LP einkaufdatum fecha de compra versione version version modell versi n Timbro del rivenditore Dealer s stamp Cachet d achat Stempel der Fachh ndlers Sello del revendedor rr nn Se POLILED COMPACT MANUALE D USO INSTRUCTION MANUAL MODE D EMPLOI GEBRAUCHSANLEITUNG FARO S p A si riserva il diritto di modificare senza preavviso le caratteristiche indicate nel presente manuale FARO S p A reserves the right to change the specifications of this equipment without notice FARO S p A se reserve le droit de modifier s ns pr avis les caract ristiques dans ce manuel FARO S p A beh lt sich recht vor jederzeit stillschweigend technische oder bauliche nderung worzunehmen FARO S p A se reserva el derecho de modificar sin aviso previo las caracteristicas incluidas en el presente manual de uso ED 06 06 COD 988172 REV 1 FARO S p A Pes Via Faro 15 e I 20060 Ornago MD Italia Tel 039 6878 1 ra MED I Fax 039 6010540 CERT 9120 FAR1 CERT 9124 FAR2 Internet http www faro it O Si z O EE Dir A DICHIARAZIONE DI CONFORMIT CE CE DECLARATION OF CONFORMITY Il fabbricante
8. CIONES DE SEGURIDAD EN FASE DE USO e La l mpara de polimerizaci n no se suministra esterilizada por lo tanto se la tiene que limpiar antes de usarla e Antes del uso esterilice en autoclave siempre solamente la fibra ptica e Con la finalidad de evitar la contaminaci n entre pacientes introduzca la fibra ptica est ril prestando atenci n para evitar el contacto con las manos o con guantes contaminados e No dirija la l mpara de polimerizaci n hacia los ojos del paciente e Desconecte el aparato de la alimentaci n el ctrica antes de toda operaci n de mantenimiento e Antes de cada tratamiento aseg rese que el dispositivo funcione perfectamente e Introduzca la fibra ptica siempre hasta el fondo del tope para evitar p rdidas de rendimiento e Reemplace inmediatamente las fibras pticas averiadas J O Si O yo i A IS O Si O yo Cio A FEHLERSUCHE Die Polymerisierlampe leuchtet nicht auf e berpr fen da der Strom eingeschaltet ist e Andernfalls den Technischen Hilfsdienst heranziehen Die Polymerisierung ist schwach e Den perfekten Zustand der optischen Faser berpr fen und eventuell diese austauschen e Andernfalls den Technischen Hilfsdienst heranziehen Was tun bei verlorengegangener oder defekter optischer Faser e Sich ausschlie lich an den FARO Kundendienst wenden Die Polymerisierlampe schaltet ab und 3 Signalt
9. IEZAS 1 Fibra ottica Optical fiber Fibre optique Optische Faser Fibra 6ptica 2 Protezione ottica Optical protection Protection optique Optischer Schutz Protecci n ptica 3 Pulsante avviamento ciclo Cycle starting button Bouton de d marrage du cycle Taste f r Vorgangsstart Pulsador de puesta en marcha del ciclo 4 Guaina di protezione Protective sheath Gaine de protection Schutzh lle Funda de protecci n 5 Cavo bipolare di connessione con connettore 2 pole power cable with connector Cable bipolaire d alimentation avec connecteur Zweipoliges Speisekabel mit Verbinder Cable bipolar de alimentaci n con conector 6 Cordino antistrappo Small tearproof cord Petit cordon anti d chirure Rei feste Kordel Cordelillo antitir n CERTIFICATO DI GARANZIA La Faro concede al cliente finale una garanzia di 24 mesi dalla data della fattura di acquisto La riparazione in garanzia dovr essere effettuata presso la FARO o presso un riparatore autorizzato FARO spese e rischi di trasporto sono a carico dell acquirente Il certificato di garanzia che si trova sul risguardo del presente libretto ritenuto valido soltanto se sar compilato in tutte le sue parti e recher il timbro del rivenditore Il certificato consentir la riparazione in garanzia durante il periodo di validit soltanto se accompagner l articolo da riparare insieme alla bolla o fattura di vendita La garanzia rispon
10. a lampe polimerisante Poliled a deux types diff rents d exposition c d e Cycle Power cycle d exposition de 20 secondes pleine puissance e Cycle Soft Ramp cycle d exposition de 20 secondes avec augmentation graduelle de l intensit lumineuse dans les premi res 10 secondes et jusqu pleine puissance UTILISATION PLEINE PUISSANCE CYCLE POWER e Appuyer bri vement sur la touche r f 3 Le DEL s allume pleine puissance pour 20 secondes e Un court signal acoustique sera mis au d but et moiti cycle et la fin du cycle il y en aura un plus long UTILISATION AVEC LA FONCTION CYCLE SOFT RAMP e Appuyer pour environ 2 secondes sur la touche ref 3 jusqu la mise en train du cycle Le DEL s allume et augmente graduellement d intensit lumineuse e Un court signal acoustique est mis au d but et moiti du cycle A la fin du cycle il y en aura un plus long INTERRUPTION VOLONTAIRE DU CYCLE e On peut arr ter l exposition n importe quel moment en appuyant sur le bouton 3 encore soit en mode Power soit en mode Soft Ramp NOTE e Pour obtenir le plein rendement v rifier que la fibre optique sera ins r e correctement et ne soit pas sale de mat riel polym risant e Selon la norme 60601 1 l instrument est adapt l utilisation intermittente avec 80 secondes ON et 10 minutes OFF e Pour des applications extr mement lourdes environ 15 cycles cons cutifs en mode Power une p
11. a ottica che trasmette la luce facilmente estraibile del corpo del dispositivo pu ruotare a 360 ed l unico componente che pu e deve essere sterilizzato in autoclave PRESCRIZIONI DI SICUREZZA IN FASE D USO e Lalampada polimerizzante non fornita sterile quindi deve essere pulita prima dell uso e Primadell uso sterilizzare in autoclave sempre e soltanto la fibra ottica e Al fine di evitare la contaminazione incrociata fra pazienti inserire la fibra ottica sterile avendo cura di evitare il contatto con mani o guanti contaminati e Non dirigere la lampada polimerizzante in direzione degli occhi del paziente e Togliere l alimentazione prima di qualsiasi intervento di manutenzione e Prima di ogni trattamento accertarsi del perfetto funzionamento dello strumento e Inserire la fibra ottica sempre sino in fondo alla battuta per evitare perdite di rendimento e Sostituire immediatamente le fibre ottiche danneggiate do O S z O CH Ce A 2 O Si O CH SE A INSTALLAZIONE Verificare che nella confezione siano contenuti i seguenti componenti gt Cordone Poliled Manuale di installazione IL DISPOSITIVO DEVE ESSERE INSTALLATO DA TECNICI SPECIALIZZATI L ALI MENTAZIONE ALL ATTO DELL INSTALLAZIONE DEVE SEMPRE ESSERE DISINSERITA e Fissare il cordone di alimentazione all interno del riunito usando il cordino antistrappo
12. alls Zweifel hinsichtlich der Wellenl nge bestehen jedoch die meisten Materialien sind f r obige nm geeignet gelten die technischen Daten des Materials bzw ist das Herstellwerk hinzuzuziehen Der vollst ndig integrierte elektronische Kreislauf im Ger t selbst soll eine konstante Lichtemission gew hrleisten e Die optische Faser f r die Lichtverbreitung kann ohne Schwierigkeiten aus dem Ger tegeh use gezogen und 360 gedreht werden dabei ist die Faser die einzige Komponente die im Autoklaven sterilisiert werden kann und mu VORKEHRUNGEN ZU DEN SICHERHEITSVORSCHRIFTEN e Die polymerisierende Lampe wird nicht steril geliefert und mu daher vor dem Einsatz gereinigt werden e Vor Gebrauch im Autoklaven ausschlie lich nur die optische Faser sterilisieren Um Um Baktierien bertragungen zwischen Patienten zu vermeiden ist die sterile optische Faser nicht mit kontaminierten H nden oder Gummihandschuhen anzufassen e Die Polymerisierlampe niemals in Richtung Augen des Patienten richten Vor jedem Wartungseingriff immer vorher den Netzstecker ziehen e Vor jeder Behandlung zun chst das Ger t auf einwandfreien Lauf pr fen e Um optimale Ergebnisse zu erreichen die optische Faser immer bis zum Anschlag einstecken e Besch digte optische Fasern immer gleich austauschen NORMES DE SECUTITE Suivre toutes les indications de ce manuel e Ce dispositif est destin l utilisation po
13. atients insert the sterile Optical Fiber while taking care to avoid contact with contaminated hands or gloves e Do not direct the Polymerizing Lamp towards the patients eyes e Turnoff power before any maintenance work e Before any treatment make sure the instrument works perfectly e Always insert the Optical Fiber completely to avoid weakened yield e Replace damaged Optical Fibers without delay e No lo utilice en presencia de portadores de estimuladores card acos u otros dispositivos semejantes e No someta la enc a u otros tejidos blandos al haz de luz Si es necesario proteja las zonas interesadas e No oriente nunca el haz luminoso hacia los ojos Coloque protecciones adecuadas en los pacientes especialmente sensibles o que han sido operados de cataratas e No utilice el aparato en pacientes que se est n haciendo tratamientos con medicamentos fotosensibilizadores Ante el caso de posible riesgo p ngase en contacto con el m dico especialista e Dispositivo sin protecci n contra la penetraci n del agua e Dispositivo no apto para el uso en ambientes en los que est presente una mezcla de anestesia inflamable con aire con ox geno o con prot xido de nitr geno e Al final de la vida til el dispositivo se tendr que eliminar manteniendo separados los diferentes materiales pl stico metal y circuito electr nico siguendo las prescripciones establecidas por la legislaci n en vigor para la eliminaci n de los equipos el
14. bed in this manual and in all other cases apply to the Service Department FARO S p A declines all responsibility for direct or indirect damage to persons or things in those cases where 1 the instrument is not used as intended 2 the instrument is not installed in accordance with the applicable standards and rules indicated 3 the instrument is not used in accordance with all the instructions and rules set forth in this manual and 4 personnel not authorized by FARO carry out modifications and repairs FEATURES e The Poliled is used in dentistry as a polymerizer of photohardening composites e As a light source it uses a high efficiency monochromatic blue LED e Wavelength emitted is between 440nm and 480nm e Although most composites are activated in this range of wavelengths in case of uncertainty refer to the technical particulars of the compound or contact the producer e The electronic circuit completely integrated in the instrument is designed and built to ensure constant light emission e The Optical Fiber transmitting the light is easy to remove from the body of the device can rotate 360 and is the only component which can and must be sterilized in an autoclave SAFETY INSTRUCTIONS DURING USE e The Polymerizing Lamp is not supplied sterile therefore it must be cleaned before use e Before using always sterilize the Optical Fiber only in the autoclave e To avoid cross contamination between p
15. ccorde au client final 24 mois de garantie partir de la date de la facture d achat Les r parations couvertes par la garantie doivent tre execut es exclusivement chez FARO ou par un r parateur autoris FARO avec les frais et les risques du transport charge de l acheteur La garantie qui se trouve sur la garde de ce livret est consider e valable seulement si celui ci est rempli enti rement et porte le timbre du revendeur Les r parations sous garantie pendant la p riode de validit seront effectu es seulement si l article reparer est accompagn du bulletin ou de la facture d achat La garantie r pond des pannes dues la mauvaise qualit du mat riel ou des d fauts de fabrication En cas de r clamation fond e la garantie permettra la r paration ou la substitution gratuite La possibilit d obtenir le d dommagement des dommages et ou des int r ts est exclue La garantie n est pas consider e valable au jugement sans appel de FARO en cas de violation d endommagement d utilisation incorrecte de mauvais entretien ou d usure normale GARANTIEZERTIFIKAT Das Haus FARO gew hart seinem Endkunden eine Garantie von 24 Monaten ab Rechnungsdatum Reparaturen sind durch das Haus FARO oder einen von der FARO befugten Reparaturbetrieb auszuf hren Transportenspesen und Risiken gehen zu Lasten des K ufers Das Garantiezertifikat im inneren Umschlagteil dieser Brosch re gilt nur dann wenn es vollst ndig ausgef
16. de dei guasti dovuti alla cattiva qualit del materiale o a difetti di fabbricazione in caso di reclamo fondato la garanzia consentir la riparazione o la sostituzione gratuita E esclusa la possibilit di ottenererisarcimento di danni e o di interessi La garanzia non ritenuta valida a insindacabile giudizio della FARO in caso di manomissione danneggiamento di scorretta utilizzazione di cattiva manutenzione o di normale usura GUARANTEE CERTIFICATE FARO grants to the final customer a 24 months guarantee starting from the date of the purchase invoice Repairs under the guarantee shall be done at the FARO premises or by an authorized FARO Service person with transportation costs and risks at the expense of the purchaser The guarantee certificate found on the endleaf of this booklet is considered valid only if it is entirely completed and bears the reseller s stamp Repairs under guarantee during the period of effectiveness will be done only if the article to be repaired is accompanied by the shipping note or purchase invoice The guarantee covers failures due to poor material quality or manufacturing detects and in case of legitimate claim the guarantee will allow repair or replacement free of charge No compensation for damages and or interest will be recognized The guarantee is not deemed valid in the final judgement of FARO in case of tampering damage incorrect use faulty maintenance or normal wear CERTIFICAT DE GARANTIE FARO a
17. dresser l assistance technique La soc FARO S p A d cline toute responsabilit pour dommages directs ou indirects aux personnes ou aux choses dans le cas ou 1 L instrument n est pas utilis pour l emploi pr vu 2 L instrument n est pas install selon les normes en vigueur et les prescriptions indiqu es 3 L instrument n est pas utilis selon toutes les instructions et les normes indiqu es dans ce manuel et 4 Des modifications et des r parations sont ex cut es par du personnel non autoris par la soc FARO S p A CARACT RISTIQUES e Le Poliled est utilis dans l odontologie comme polym riseur de composites photodurcissables e Comme source lumineuse un diode DEL monochromatique bleu haute efficience est utilis e La longueur d onde mise est entre 440nm et 480nm e Bien que la plupart des composites soit activ es dans cette intervalle de longueur d onde en cas d incertitude se r f rer aux donn es techniques du compos ou se mettre en contacte avec le producteur e Le circuit lectronique compl tement int gr dans l instrument a t projet et r alis pour assurer l mission constante de lumi re e La fibre optique qui transmet la lumi re est facile extraire du corps de l appareil peut tourner 360 et est le seul composant qui peut et doit tre st rilis dans l autoclave NORMES DE S CURIT PENDANT L EMPLOI e La lampe polym risa
18. ec ON e 10 OFF e In caso di applicazioni estremamente gravose circa 15 cicli consecutivi in modalit Power una protezione termica di sicurezza provvede a spegnere lo strumento In questi casi un eventuale aumento della temperatura esterna dello strumento da ritenersi normale L utilizzo rester inibi to per alcuni minuti Il completo ripristino avverr dopo circa 15 min MANUTENZIONE LO STRUMENTO NON E PROTETTO CONTRO LA PENETRAZIONE DEI LIQUIDI STERILIZZARE SOLO LA FIBRA OTTICA ELA PROTEZIONE OTTICA Per sterilizzare la fibra ottica procedere nel seguente modo e Estrarre la fibra ottica dal corpo della lampada polimerizzante tirandola assialmente e Sterilizzare la fibra ottica in autoclave e Reinserire la fibra facendola ruotare leggermente su se stessa sino alla battuta PULIZIA Per la pulizia della lampada polimerizzante procedere nel seguente modo e Prima di effettuare la pulizia spegnere l interruttore generale di alimentazione e Perla pulizia utilizzare un panno morbido leggermente inumidito con alcool analoghi detergenti avendo cura di non farli penetrare nelle parti interne LIMPIEZA Para limpiar la lampara de polimerizaci n proceda como se explica a continuaci n e Antes de limpiar apague el interruptor general de alimentaci n e Para limpiar utilice un pa o suave ligeramente humedecido en alcohol o detergentes similares teniendo cuidado de que dichos
19. ectr nicos e Ejecute s lo las operaciones ilustradas en el presente manual en cualquier otro caso dir jase al servicio de asistencia t cnica FARO S p A no se hace responsable por da os directos o indirectos a personas o cosas en caso que 1 El instrumento no se utilice para el uso previsto 2 El instrumento no est instalado seg n las normas vigentes y las prescripciones indicadas 3 El instrumento no se utilice siguiendo todas las instrucciones y prescripciones descritas en el presente manual 4 Las operaciones de modificaci n y reparaci n se hayan encargado a personal no autorizado por FARO CARACTERISTICAS e El dispositivo Poliled se utiliza en odontolog a como polimerizador de compuestos fotoendurecedores e Como fuente luminosa se utiliza un diodo led monocrom tico azul de alta eficiencia e La longitud de onda emitida est comprendida entre 440 y 480 nm e Si bien la mayor parte de los compuestos se activan en dicho intervalo de longitud de onda ante la duda tome como referencia los datos t cnicos del compuesto o consulte al personal de la casa productora e El circuito electr nico totalmente integrado en el instrumento ha sido proyectado y realizado para garantizar una emisi n constante de la luz e Lafibra ptica que transmite la luz se puede extraer con facilidad del cuerpo del dispositivo puede girar a 360 y es el nico componente que puede y debe esterilizarse en autoclave PRESCRIP
20. erica da 500 a 1060 mBar Smaltire il dispositivo attenendosi alle norme per la raccolta differenziata del X materiale elettrico 2 O Si O ya A d O Si O yo Fe A SAFETY RULES Follow all the instructions set forth in this manual e This device is used to polymerize composite photohardening resins with photo starter activable in the band length between 440nm and 480nm in dentistry and must be used in a dentist s office only by medical personnel e Do not use in the presence of users of pacemakers or other implantable devices e Do not subject the gums or other soft tissues to the light beam If necessary protect any parts involved e Do not direct the light beam towards the eyes Provide purposeful protection for very sensitive patients or those who undergo cataract surgery e Do not use this equipment for patients undergoing treatment with photosensitizing drugs In case of risk contact the specialized doctor e This device is not protected against water penetration e This device is not suited for use in environments with a mixture of anesthetic inflammable with air oxygenor nitrous oxide e At the end of its operational life this device must be disposed of with separation of the different materials plastic metal electronic circuits following the legislation applicable for disposal of electronic equipment e Perform only the operations descri
21. ermica Attendere alcuni minuti prima di riutilizzarla La superficie dello strumento si scaldata e Avete eseguito un numero considerevole di cicli Fate riposare lo strumento e Seil problema persiste scollegare lo strumento dal cordone e farlo raffreddare quindi ricollegarlo Se lo strumento si scalda nuovamente senza utilizzarlo scollegarlo definitivamente e contattare l assi stenza tecnica SPECIFICHE TECNICHE Applicazione Polimerizzazione di materiali dentali fotoindurenti Alimentazione da 17 a 26 V ac da 19 a 34 V dc 50 Hz Consumo 11 5 VA Grado di protezione contro i contatti diretti e indiretti apparecchio di tipo B Lunghezza d onda 440 480 nm Protezione contro pericoli elettrici apparecchio di classe II Dimensione dello strumento Lunghezza 165 mm Cordone fisso sullo strumento Fibra ottica 8 sterilizzabile a 134 C Diam Max 27 mm Normative applicate EN 60601 1 EN 60601 1 2 Peso 110 g Sorgente luminosa N 1 Led da 5W con concentratore ottico Tempi di lavoro Ciclo standard 20 sec alla massima potenza Ciclo Rampa 10 sec da zero alla massima potenza 10 sec alla massima potenza Segnali acustici Inizio e dopo ogni 10 sec L apparecchio nel suo imballo per il trasporto e l immagazzinamento in grado di sopportare per un periodo massimo di 15 settimane le seguenti condizioni ambientali Temperatura ambiente da 20 C a 70 C Umidit relativa dal 10 al 90 Pressione atmosf
22. hort acoustic signal is emitted at the beginning and halfway thru cycle A longer sound is heard at cycle end USING WITH SOFT RAMP FUNCTION e Hold down button 3 for about 2 seconds until cycle start The LED lights up and increases intensity gradually e A short acoustic signal is emitted at the beginning and halfway thru cycle A longer sound is heard at cycle end VOLUNTARY STOPPING THE CYCLE e Exposure can be stopped at any moment by again pressing a button 3 whether in Power or Soft Ramp mode NOTE e To obtain full output make sure the Optical Fiber is inserted correctly and is not fouled with polymerizing material e In accordance with std 60601 1 the instrument is suited for intermittent use with 80 seconds ON and 10 minutes OFF e Forextremely heavy applications approximately 15 consecutive cycles in Power mode a thermal safety protection shuts off the instrument In these cases any increase in temperature outside of the instrument is considered normal Use will be inhibited for a few minutes Complete resetting will take place after approximately 15 minutes MAINTENANCE THE INSTRUMENT IS NOT PROTECTED AGAINST THE PENETRATION OF LIQUIDS STERILIZE ONLY THE OPTCAL FIBER To sterilize the Optical Fiber proceed as follows e Withdraw the Optical Fiber from the body of the Polymerizing Lamp by pulling it axially e Sterilize the Optical Fiber in an autoclave e Refit the Optical Fiber by rotating it slightly
23. iffe reantiated collection of electrical material RH INSTALLATION Bitte darauf achten da in der Packung folgende Teile enthalten sind gt Poliled Leitung gt Installieranweisung DAS GER T DARFNUR VON FACHTECHNIKERN INSTALLIERT WERDEN BEIM INSTALLIEREN MUSS UNBEDINGT DER NETZSTECKER GEZOGEN SEIN e Die Speiseleitung im Inneren des Aggregats mit Hilfe der rei festen Kordel befestigen und zwar derart da das Ziehen der Kordel nicht die Speisekabel rei t e Die Speisekabel ausschlie lich nur an einen Transformator mit sehr niedriger Sicherheitsspannung anschlie en siehe auch unter Sicherheitsvorschriften GEBRAUCHSANLEITUNG Die Polymerisierlampe Poliled sieht zwei verschiedene Belichtungstypen vor e Vorgang Power Belichtungsvorgang 20 Sekunden bei maximaler Leistung e Vorgang Soft Rampa Belichtungsvorgang 20 Sekunden bei steigender Lichtst rke in den ersten 10 Sekunden bis zur Maximalleistung GEBRAUCH BEI MAXIMALER LEISTUNG VORGANG POWER e Kurz die Taste Bezug 3 dr cken Das Led leuchtet bei maximaler Leistung 20 Sekunden lang auf e Ein kurzes Tonsignal ert nt beim Start und bei halbem Vorgang am Ende des Vorgangs ist der Ton lang GEBRAUCH MIT RAMPENBETRIEB VORGANG SOFT RAMPA e Die Taste Bezug 3 circa 2 Sekunden bis zum Anlauf des Vorgangs dr cken Das Led leuchtet auf und wird laufend st rker e Ein kurzes Tonsignal ert nt beim Start und bei halbem Vo
24. in modo che una trazione del cordone non provochi la tensione dei cavi di alimentazione ISTRUZIONI D USO La lampada polimerizzante Poliled prevede due diversi tipi di esposizione e Ciclo Power ciclo di esposizione di 20 secondi alla massima potenza e Ciclo Soft Rampa ciclo di esposizione di 20 secondi con aumento graduale dell intensit lumino sa nei primi 10 secondi fino alla massima potenza USO ALLA MASSIMA POTENZA CICLO POWER e Premere brevemente il pulsante rif 3 Il led si accende alla massima potenza per 20 sec e Una breve segnalazione acustica verr emessa allo start e a met ciclo mentre alla fine ciclo ve ne sar una di pi lunga durata USO CON FUNZIONE RAMPA CICLO SOFT RAMPA e Tenere premuto per circa due secondi il pulsante rif 3 sino all avviamento del ciclo Il led si accende aumentando gradualmente l intensit luminosa e Unabreve segnalazione acustica verr emessa allo start e a met ciclo mentre alla fine del ciclo ve ne sar una di pi lunga durata INTERRUZIONE VOLONTARIA DEL CICLO e Sia nella modalit Power che in quello Soft rampa l esposizione pu essere interrotta in qualsiasi istante premendo nuovamente il pulsante rif 3 NOTA e Perottenere il massimo rendimento verificare che la fibra ottica sia inserita perfettamente e non sia sporca di materiale polimerizzante e Secondo la norma 60601 1 lo strumento adatto all uso intermittente con 80 s
25. inutos antes de volver a utilizar La superficie del instrumento se ha recalentado e Se ha realizado un n mero excesivo de ciclos Haga descansar el instrumento e Si el problema persiste desconecte el instrumento del cable y d jelo enfriar despu s vuelva a conectarlo Si el instrumento se recalienta otra vez sin utilizarlo descon ctelo definitivamente y p ngase en contacto con la asistencia t cnica ESPECIFICACIONES TECNICAS Alimentaci n 24 V c a Consumo 11 5 VA Grado de proteccion contra contactos directos e indirectos aparato de tipo B Longitud de onda 440 480 nm Proteccion contra los peligros el ctricos aparato de clase II Dimensiones del instrumento Largo 165 mm Cable fijo en el instrumento Fibra ptica 8 esterilizable en autoclave Di m m x 27 mm Normas aplicadas EN 60601 1 EN 60601 1 2 Peso 110g Fuente luminosa 1 led de 5 W con concentrador ptico Tiempos de ejercicio Ciclo est ndar 20 seg a la m xima potencia Ciclo Rampa 10 seg de cero a la m xima potencia 10 seg a la m xima potencia Se ales ac sticas Inicio y despu s cada 10 seg Almacenamiento con embalaje ntegro por un m ximo de 15 semanas con Temperatura ambiente entre 20 C y 70 C gt Humedad relativa del 10 al 90 gt Presi n atmosf rica de 500 a 1060 mBar Contenedor de basura para eliminaci n de residuos Eliminar el dispositivo respetando X las normas de recogida selectiva del material el c
26. l quidos no penetren en el interior del dispositivo e El posible residuo de material de reconstrucci n incrustado en la fibra ptica o en el cuerpo de la l mpara se tiene que eliminar con instrumental achaflanado de material pl stico e Para mantener siempre el m ximo rendimiento limpie cotidianamente con un pa o seco las dos caras de la fibra ptica de todas formas la limpieza de las mismas se tiene que realizar antes de cada esterilizaci n e Controle peri dicamente el estado de la fibra ptica el aspecto de la superficie de la misma tiene que presentarse homog neo sin halos ni manchas Las posibles anomal as influyen negativamente sobre el rendimiento de la polimerizaci n GUIA DE LOS PROBLEMAS MAS COMUNES La l mpara de polimerizaci n no se enciende e Controle que la alimentaci n el ctrica est conectada e Si el problema persiste p ngase en contacto con la asistencia t cnica El poder de polimerizaci n es limitado e Controle que la fibra ptica est en perfecto estado y limpia reemplaz ndola si es necesario e Si el problema persiste p ngase en contacto con la asistencia t cnica La fibra ptica se ha perdido o est rota e Para obtener una nueva hay que dirigirse exclusivamente a los centros de asistencia FARO La l mpara de polimerizaci n se apaga antes y emite 3 se ales ac sticas obstaculiz ndose los ciclos siguientes e Se ha activado la protecci n t rmica Espere algunos m
27. la l mpara de polimerizaci n tir ndola en forma axial e Esterilice la fibra ptica en autoclave e Vuelva a colocar la fibra haci ndola girar ligeramente sobre si misma hasta el tope e L eventuale residuo di materiale da ricostruzione incrostato sulla fibra ottica o sul corpo della lampada deve essere rimosso con attrezzi di materiale plastico smussato e Per avere sempre il massimo rendimento pulire quotidianamente con un panno asciutto le due facce della fibra ottica La pulizia delle due facce della fibra ottica deve comunque essere fatta prima di ogni sterilizzazione e Esaminare periodicamente lo stato della fibra ottica l aspetto della sua superficie deve apparire omogeneo senza aloni o macchie Eventuali anomalie influiscono negativamente sul rendimento della polimerizzazione GUIDA AI PROBLEMI PIU COMUNI La lampada polimerizzante non si accende e Controllare che l alimentazione elettrica sia inserita e Se il problema persiste contattare l assistenza tecnica Il potere polimerizzante limitato e Verificare l integrit e la pulizia della fibra ottica e ed eventualmente sostituirla e Se il problema persiste contattare l assistenza tecnica La fibra ottica viene smarrita o rotta e Peril reperimento d obbligo rivolgersi esclusivamente ai centri di assistenza FARO La lampada polimerizzante si spegne prima ed emette 3 beep inibendo i cicli successivi e E intervenuta la protezione t
28. lla vita operativa il dispositivo dovr essere smaltito tenendo separati i vari materiali plastica metallo e circuito elettronico seguendo le prescrizioni legislative vigenti per lo smaltimento delle apparecchiature elettroniche e Eseguire solo le operazioni illustrate nel presente manuale in qualsiasi altro caso rivolgersi all assistenza tecnica La FARO S p A declina ogni responsabilit per danni diretti o indiretti a persone o cose nei casi in cui 1 Lo strumento non utilizzato secondo la destinazione d uso prevista 2 Lo strumento non installato secondo le norme vigenti e le prescrizioni indicate 3 Lo strumento non utilizzato conformemente a tutte le istruzioni e prescrizioni descritte nel presente manuale 4 Le operazioni di modifiche e riparazioni sono effettuate da personale non autorizzato FARO CARATTERISTICHE e IlPoliled utilizzato in odontoiatria come polimerizzatore di compositi fotoindurenti e Come sorgente luminosa viene utilizzato un diodo led monocromatico blu ad alta efficienza e Lalunghezza d onda emessa compresa tra 440 480 nm e Sebbene la maggior parte dei compositi si attivano in questo intervallo di lunghezza d onda in caso di incertezza fare riferimento ai dati tecnici del composto o contattare la casa produttrice e Il circuito elettronico totalmente integrato nello strumento stato progettato e realizzato per garan tire un emissione della luce costante e La fibr
29. ne blockieren die weiteren Vorg nge e Der W rmeschutz hat sich eingeschaltet Einige Minuten abwarten erst dann wieder betreiben Das Geh use erw rmt e Es wurden viele Vorg nge hintereinander ausgef hrt Das Ger t mu einige Zeit ausrasten e Falls das Problem weiterhin besteht auch den Stecker ziehen und das Ger t abk hlen lassen Erst dann wieder einschalten Wenn sich das Ger t bei Wiedereinschalten ohne jeglichen Vorgang weiterhin erw rmt ist der Technische Hilfsdienst heranzuziehen TECHNISCHE DATEN Anwendung Polymerisierung von lichth rtendem Zahnmaterial Speisung 17 26 VWS 19 34 Verbrauch 11 5 VA Sicherheitsgrad des direkten und indirekten Kontaktes Ger t der Klasse B Wellenl nge 440 480 nm Ger tesschutzisolierung der Schutzklasse Ger t der Klasse II Ger tabmessungen L nge 165 mm Leitung das Versorgungskabel ist fest mit dem Instrument verbunden Optische Faser 8 sterilisierbar im Autoklaven Durchm max 27 mm Angewandte Normen EN 60601 1 EN 60601 1 2 Gewicht 110g Lichtquelle N 1 Led zu 5W mit optischem Konzentrierer Betriebsdauern Standardvorgang 20 Sek bei maximaler Leistung Rampenvorgang 10 Sek von Null auf maximale Leistung 10 Sek bei maximaler Leistung Lautsignale Zu Beginn und jeweils nach 10 Sek Das Ger t kann im verpackten Zustand f r den Transport bzw die Lagerung 15 Wochen unter folgenden Bedingungen verharren gt Umgebungstemperatur
30. nte n est pas fournie st rile donc il faut la nettoyer avant de s en servir e Avant l emploi steriliser en autoclave toujours et seulement la fibre optique e Afin d viter la contamination crois e entre patients inserire la fibre optique st rile en ayant soin d eviter le contact avec les mains ou des gants contamin s e Ne pas diriger la lampe polimerisante vers les yeux du patient e Eteindre le courant avant tout entetien e S assurer avant tous traitement que l instrument fonctionne parfaitement e Inserer toujours la fibre optique jusqu au fond de la but e pour viter la perte de rendement e Remplacer tout de suite les fibres optiques endommag s 2 O Si O yo Si A 2 O Si z Q yo Se A INSTALLATION Verifier qu il ya dans l emballage les composants suivants Cordon Poliled gt Manuel d installation LE DISPOSITIFT DOIT ETRE INSTALL PAR DES TECHNICIENS SP CIALIS S AU MOMENT DE L INSTALLATION L ALIMENTATION DOIT TOUJOUS TRE D BRANCH E e Fixer le cordon d alimentation l int rieur du fauteuil au moyen du petit cordon antid chirure de mani re qu une traction du cordon ne provoque pas la tension des c bles d alimentation e Brancher les c bles d alimentation seulement un transformateur tension tr s basse de s curit voir aussi les avertissements de s curit MODE D EMPLOI L
31. ontacts directs et indirects appareil de type B Longueur d onde de 440nm 480nm Protection contre les dangers electriques appareil de classe II Dimensions de l instrument longueur 165mm Cordon fix sur la lampe Fibre optique dia 8 autoclavable 134 C dia maximum 27mm R glementation en vigueur EN 60601 1 et 60601 1 2 Poids 100 g Source lumineuse une DEL de 5W avec concentrateur optique Temps de travail Cycle normal puissance totale secondes 20 Cycle de Rampe de z ro pleine puissance secondes 10 10 secondes pleine puissance Signaux acoustiques au d but et apr s chaque 10 secondes Dans son emballage de transport et d emmagasinage cet appareil peut supporter pour une p riode de 15 semaines les conditions environnementales suivantes gt Temp rature environnementale de 20 C 70 C gt Humidit relative de 10 90 gt Pression atmosph rique de 500 1060 mbar X Bac pour limination d chets Eliminer le dispositif conform ment aux normes relatives la collecte s par e des d chets 2 O Si O CH A
32. r duraci n USO CON FUNCION RAMPA CICLO SOFT RAMPA e Tenga presionado por dos segundos aprox el pulsador ref 3 hasta que se pone en marcha el ciclo El led se enciende aumentando gradualmente la intensidad luminosa e Se emite una se al ac stica breve al principio y a la mitad del ciclo mientras que al final del ciclo se emite una se al ac stica de mayor duraci n INTERRUPCION VOLUNTARIA DEL CICLO e Tanto en el modo Power como en el Soft rampa la exposici n se puede interrumpir en cualquier instante pulsando nuevamente el pulsador ref 3 NOTA e Para obtener el m ximo rendimiento controle que la fibra ptica est perfectamente colocada y que no est sucia de material de polimerizaci n e Seg n la norma 60601 1 el dispositivo es apto para uso intermitente con 80 seg ON y 10 OFF e En el caso de aplicaciones extremadamente exigentes 15 cielos aprox consecutivos en modo Power una protecci n t rmica de seguridad se encarga de apagar el dispositivo En estos casos un posible aumento de la temperatura exterior del instrumento es normal La utilizaci n no ser posible durante algunos minutos La reactivaci n completa se producir despu s de 15 min aprox MANTENIMIENTO EL INSTRUMENTO NO ESTA PROTEGIDO CONTRA LA PENETRACION DE LOS LIQUIDOS ESTERILICE SOLO LA FIBRA OPTICA Para esterilizar la fibra ptica proceda como se explica a continuaci n e Extraiga la fibra ptica del cuerpo de
33. raci n o reemplazo gratuitos Se excluye la posibilidad de obtener resarcimiento por da os y o por intereses La garanti no es v lida a completa discreci n de FARO en caso de modificaciones no autorizadas de alteraciones de empleo incorrecto de mantenimiento indebidoo de desgaste normal NORME DI SICUREZZA Seguire tutte le indicazioni riportate nel seguente manuale e Il dispositivo serve per polimerizzare le resine composite fotoindurenti con fotoiniziatore attivabile nella banda di lunghezza compresa tra 440 480 nm in odontoiatria e deve essere utilizzato in uno studio dentistico solo da personale medico e Non utilizzare in presenza di portatori di stimolatori cardiaci o altri dispositivi impiantabili e Non sottoporre la gengiva o altri tessuti molli al fascio di luce Se necessario proteggere le eventuali parti interessate e Non orientare mai il fascio luminoso in direzione degli occhi Prevedere apposite protezioni nei pazienti particolarmente sensibili o che sono stati sottoposti ad interventi chirurgici di cataratta e Non utilizzare l apparecchio nei pazienti in corso di trattamento con farmaci fotosensibilizzanti Nei casi di possibile rischio contattare il medico specialista e Dispositivo non protetto contro la penetrazione dell acqua e Dispositivo non adatto per uso in ambienti con presenza di una miscela anestetica infiammabile con aria con ossigeno o con protossido di azoto e Alla fine de
34. re optique Sa superficie doit appara tre homog ne uniforme et sans halo ou taches D ventuelles anomalies influence n gativement le rendement de la polym risation GUIDE AUX PROBL MES LES PLUS COMMUNS La lampe polym risante ne s allume pas e S assurer que le cordon d alimentation est branch e Si le probl me continue s adresser au Service Technique La puissance polym risante est insuffisante e Contr ler la condition et le nettoyage de la fibre optique la remplacer si n cessaire e Si le probl me continue s adresser au Service Technique La fibre optique est perdue ou cass e e Pour en trouver s adresser uniquement aux centres d assistance FARO La lampe polym risante s teint trop t t et mette trois bips en interdisant les cycles successifs e La protection thermique est intervenue Attendre quelques minutes avant de la reutiliser La surface de l instrument s est chauff e e Vous avez ex cut beaucoup de cycles Laisser reposer l instrument e Sile probl me persiste d brancher l instrument du cordon et la faire refroidir puis le rebrancher Si l instrument se chauffe encore sans qu on l utilise le d brancher d finitivement et contacter le Service Technique SP CIFICATIONS TECHNIQUES Application polym risation de mat riaux dentaux photodurcissables Alimentation Vca 17 26 19 34 50 HZ Consommation VA 11 5 Degr de protection contre les c
35. rgang am Ende des Vorgangs ist der Ton lang VORGANGSUNTERRECHUNG e Sowohl in der Funktion Power als auch Soft rampa kann die Belichtung jederzeit unterbrochen werden hierzu gen gt es erneut die Taste Bezug 3 dr cken ANMERKUNGEN e Zur Ereichung der H chstleistung ist zu pr fen da die optische Faser einwandfrei eingesteckt wurde und ihr keinerlei Polymerisiermaterial anhaftet e Entsprechend der Norm 60601 1 ist das Ger t f r intermittierenden Einsatz und zwar 80 Sek ONund 10 OFF e Bei sehr schwerem Einsatz circa 15 Vorg nge hintereinander im Power Zustand schaltet ein Sicherheitsw rmeschutz das Ger t ab In solche F llen kann ein Erw rmen des Ger ts als normal angesehen werden Der Gebrauch des Ger ts bleibt einige Minuten unterbrochen Nach ca 15 Minuten kann es wieder eingesetzt werden WARTUNG DAS GER T IST NICHT GEGEN EINDRINGEN VON FL SSIGKEITEN GESCH TZT ES DARF NUR DIE OPTISCHE FASER STERILISIERT WERDEN Die optische Faser wird wie folgt sterilisiert e Die optische Faser aus der Polymerisierlampe achsial ziehen e Die optische Faser im Autoklaven sterilisieren e Erneut die optische Faser durch leichtes Drehen bis zum Anschlag einf hren REINIGUNG Zur Reinigung der Polymerisierlampe wie folgt vorgehen e Zun chst den Netzstecker ziehen e Ein leicht mit Spiritus oder hnlichen Mitteln getr nktes weiches Tuch zur Reinigung verwenden keinesfalls Fl ssigkeiten ins Ger
36. rotection thermique de s curit teint l instrument En ces cas une augmentation de la temp rature ext rieure de l instrument est consid r e normale L utilisation sera interdite pour quelques minutes Le r tablissement complet aura lieu apr s environ 15 minutes ENTRETIEN L INSTRUMENT N EST PAS PROT G CONTRE LA P N TRATION DE LIQUIDES ST RILISER SEULEMENT LA FIBRE OPTIQUE St riliser la fibre optique comme suit e Extraire la fibre optique du corps de la lampe polym risante en la tirant axialement e St riliser la fibre optique dans un autoclave e Reins rer la fibre en la faisant tourner l g rement sur elle m me jusqu la but e NETTOYAGE Pour nettoyer la lampe polym risante proc der comme suit e Avant de proc der au nettoyage teindre l interrupteur principal e Utiliser un chiffon mou l g rement humect avec de l alcool ou de d tergents du m me genre en ayant soin de ne pas les faire p n trer l int rieur e Du r sidu de mat riaux de reconstruction incrust s sur la fibre optique ou sur le corps de la lampe doit tre limin avec des outils en mati re plastique mouss e Pour obtenir toujours le rendement meilleur nettoyer chaque jour avec un chiffon sec les deux faces de la fibre optique Le nettoyage des deux faces de la fibre optique doit tre fait en tous cas avant chaque st rilisation e Examiner p riodiquement la condition de la fib
37. t einlaufen lassen e Eventuelle R ckst nde von Materialien welche die optische Faser bzw die Lampe verkrusten mit abgerundeten Plastikschabern entfernen e F r eine immer einwandfreie Leistung sind beide Seiten der optischen Faser t glich mit einem trockenen weichen Tuch zu reinigen Eine solche Reinigung mu immer vor dem Sterilisiervorgang erfolgen e Den Zustand der optischen Faser regelm ig kontrollieren hierbei mu die Oberfl che glatt sein und darf keine R nder noch Flecken aufweisen da hierdurch die Polymerisierung verschlechtert wird 2 O Si O yo Si A 2 O Si z Q yo Lem EE A SICHERHEITSNORMEN Die nachstehenden Anweisungen sind aufmerksam zu befolgen e Das Ger t dient zur Polymerisation von zusammengesetzten lichth rtenden Kunststoffharzen mit Photoinitiator der innerhalb der Bandl nge zwischen 440 480 nm bet tigt werden kann im zahn rztlichen Bereich und darf nur in der Zahnarztpraxis und durch rztliches Personal gebraucht werden e Das Ger t darf nicht in Gegenwart von Personen mit Pace maker oder anderen einoperierten Ger ten verwendet werden e Das Zahnfleisch und andere Weichgewebe d rfen nicht unter den Lichtstrahl gelangen Notwendigenfalls diese Teile abschirmen e Niemals den Lichtstrahl auf die Augen richten Bei empfindlichen Patienten und solchen die einer Kateraktoperation unterzogen wurden immer geeignete
38. trico 25 O Si Q yo i A ds O Si z Q ys SE A INSTALACION Controle que en el embalaje esten presentes los siguientes componentes gt Cable Poliled gt Manual de instalaci n LA INSTALACION DEL DISPO SITIVO TIENE QUE CONFIARSE A TECNICOS ESPECIALIZADOS CUANDO SE ESTA REALIZANDO LA INSTALACION EL DISPO SITIVO TIENE QUE ESTAR SIEMPRE DESCONECTADO DE LA ALIMENTACION e Fije el cable de alimentaci n en el interior de la unidad de asistencia usando el cordelillo antitir n de manera que ninguna fuerza de tracci n del cable provoque la tensi n de los cables de alimentaci n e Conecte los cables de alimentaci n exclusivamente a un transformador de baj sima tensi n de seguridad v anse tambi n las advertencias de seguridad INSTRUCCIONES PARA EL USO La l mpara de polimerizaci n Poliled est concebida para dos tipos de exposici n diferentes e Ciclo Power ciclo de exposici n de 20 segundos a la m xima potencia e Ciclo Soft Rampa ciclo de exposici n de 20 segundos con aumento gradual de la intensidad luminosa en los primeros 10 segundos hasta la m xima potencia USO A LA MAXIMA POTENCIA CICLO POWER e Pulse brevemente el pulsador ref 3 El led se enciende a la m xima potencia por 20 seg e Se emite una se al ac stica breve al principio y a la mitad del ciclo mientras que al final del ciclo se emite una se al ac stica de mayo
39. ur polym riser des r sines composites photodurcissables avec photo initiateur activable dans la bande de la longueur entre 440nm et 480nm en odontologie et doit tre utilis dans un cabinet de dentiste uniquement par du personnel m dical e Ne pas l utiliser en pr sence de porteurs de stimulateur cardiaque ou autres appareils implantables e Ne pas soumettre les gencives ou d autres tissus mous au faisceau de lumi re En cas de besoin prot ger les parties int ress es e Ne jamais diriger le faisceau de lumi re vers les yeux Pr voir des protections pour les patients particuli rement sensibles ou qui ont t soumis la chirurgie de la cataracte e Ne pas utiliser l appareil pour des patients qui subissent un traitement aux m dicaments photosensibilisant En cas de risques s adresser un m decin sp cialis e Ce dispositif n est pas prot g contre la p n tration de l eau e Ce dispositif n est pas adapt pour l emploi dans un milieu qui contient un m lange anesth tique inflammable avec l air avec l oxyg ne ou avec le protoxyde d azote e A la fin de sa vie op rationnelle ce dispositif doit tre limin en s parant les divers mat riaux c d la mati re plastique le m tal et les circuits lectronique en suivant les normes l gislatives en vigueur pour l limination des appareils lectronique e Ex cuter seulement les op rations d crites dans ce manuel En tout autre cas s a