1. 18 20 AL 40 24 36 44 30 42 50 36 48 56 42 54 62 48 60 68 54 66 74 60 Te 80 This required width allows for centering of the log set Table 1 Minimum Firebox Dimensions Rev 1 1306140730 Model Maximum BTUs EPK 2V P 100 000 EPK 3V P 200 000 Table 2 BTUs lt Center width L A2 352 REPLACEMENT PARTS LIST 2V MODEL DO NOT REMOVE THE PILOT IGNITER ASSEMBLY FROM THE VALVE OR IGNITER PACK Note Photos not to scale Rev 1 1806140730 Pilot igniter assembly natural Pilot igniter assembly propane Pilot mounting bracket kit Control valve natural Control valve propane Ignition module pack Remote Flame diverter bracket Switch box w switch battery pack and wire harness Main wire harness Heat shield 6 L A2 352 REPLACEMENT PARTS LIST 3V MODEL DO NOT REMOVE THE PILOT IGNITER ASSEMBLY FROM THE VALVE OR IGNITER PACK Rev 1 1306140730 Pilot igniter assembly natural Pilot igniter assembly propane Pilot mounting bracket kit Control valve natural Control valve propane Ignition module pack Remote Flame diverter bracket Switch box w switch battery pack and wire harness Main wire harness Heat shield L A2 352 INSTALLATION This safety pilot system must be installed by a qualified professional service technician Instructions must be followed carefully when installing to ensure proper p
2. 1 8 The maximum is 9 39 If the electrode ceramic is loose in the threaded barrel the pilot assembly must be replaced Detail B Terminal Connections B All of the connections on the control module must be properly attached If the spade terminals are loose inspect to ensure they correctly appear as detailed below Use needle nose pliers to clamp down on the center sides of the terminals if needed to provide a tight fit Spade Terminal Detail eee CORRECT INCORRECT Ensure that spade terminals S and I are attached securely Ensure that multi wire connector is proper y L locked in place Control Module Fig B 2 DESIGN MAY VARY 1 8 min gap Hood Spark electrode 14 Sensor electrode 1 8 Electrode Ceramic min gap Threaded barrel rig A 1 7 Gr W Retainer nuts DetailC a DO NOT bundle tightly together as shown Assembly Wires C DO NOT bundle the excess pilot assembly wires tightly together as this can reduce the intensity of the spark WARRANTY PETERSON VENTED DECORATIVE GAS APPLIANCE LIMITED WARRANTY All Peterson gas logs are WARRANTED for as long as you own them lifetime All Peterson burner assemblies are WARRANTED for TEN 10 YEARS All Peterson glass is WARRANTED for FIVE 5 YEARS SPK 26 controls are covered by a THREE 3 YEAR All Parts Warranty APK 17 controls are covered by a TWO
3. 2 YEAR All Parts Warranty All other Peterson valves pilots and controls are covered by a ONE 1 YEAR Limited Warranty excluding batteries PLEASE KEEP A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE This warranty applies to the original purchaser and to single family residential use only It commences from date of purchase and is valid only with proof of purchase This warranty does not cover parts becoming defective through misuse accidental damage electrical damage improper handling lack of routine maintenance storage and or installation Product must be installed and gas must be connected as specified in the instructions or operator s manual by a qualified professional installer Accessories parts valves remotes etc when used must be Peterson Co product This warranty does not apply to rust corrosion oxidation or discoloration unless the affected component becomes inoperable It does not cover labor or labor related charges This warranty specifically excludes liability for indirect incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specified legal rights and you may have other rights that may vary from state to state For additional information regarding this warranty or to place a warranty claim contact the R H Peterson dealer where the product was purchas
4. 8 2 Take care not to damage the attached pilot assembly when rotating the burner pan Be sure all connections are tight Important The rear of the valve may need to be angled slightly upward to allow for the pan to sit flat against the fireplace floor Adjust as necessary INSTALL THE FLAME DIVERTER BRACKET Forinstallation on G4 G45 burners only When properly installed onto the burner pan the flame diverter bracket will promote quicker ignition and protect the safety control system from overheating Note You must first install the flame diverter bracket before installing the pilot igniter assembly Use only the pilot igniter assembly pre assembled with this kit Never substitute with an existing pilot 1 Place the flame diverter bracket over the side edge of the burner pan near the location the safety control system pilot bracket will be attached It should be placed approximately 2 1 5 from the rear wall of the burner pan see Fig 8 3 Rev 1 1306140730 8 Fasten bracket to burner pan Install for 2V and 3V valves is the same 2V SHOWN Attach the valve to the air mixer fuel injector by rotating the burner pan Fuel injector or air mixer OA see ha F 0 a xa jA onl Adapter Valve REAR WALL Burner Ss pan O diverter bracket L A2 352 INSTALLATION Cont 2 lap the bracket lightly with a hammer to secure it in place INSTALL THE PILOT IGNITER ASSEMBLY TO THE BURNER CAUTION
5. Do not kink or damage the pilot supply tube 11 sparking and sensor probes Do not unscrew Fasten pilot i assembly to the gas line from the valve a Valve not shown 1 Using the two 2 remaining screws mount the pilot for clarity assembly onto the bracket from below and tighten until snug Fig 9 1 Check to be certain the pilot hood and probes are situated above the edge of the pan Adjust if necessary Attach the flex rear view of valve Pilot assembly installed Fig 9 1 2 The valve is shipped with the pilot supply tube bentin connector to anideal manner to prevent damage unsafe operation the elbow on and to allow for proper heat shield placement Maintain the valve this orientation at all times reference Fig 9 2 or 9 3 WARNING Keep the pilot igniter assembly clear at all times Never cover any part of the pilot igniter assembly CONNECT TO THE GAS SUPPLY To connect the valve to the gas supply the flex connector kitand component parts will be needed which are included with the burner system Refer to the PARTS LIST in the instructions supplied with the burner to identify the key parts needed 1 Be sure gas to the fireplace is off Apply gas pipe sealing compound or Teflon tape to the male end of the gas stub Attach the adapter from the flex connector kit to the gas supply stub in the fireplace 2 Attach the flex connector to the elbow adapter on the control valve see Fig 9 2 or Fig 9 3 U
6. functioning Obstruction in pilot gas supply or pilot gas supply line is kinked Inadequate gas supply Air in line Gas is shut off on control valve 3V models only Loose wires Dead batteries Faulty switch or remote if equipped Loose or broken connector wires Batteries too low for voltage output Defective valve Low flame uneven flame Glass doors closed causing excessive heat buildup Pilot electrode not properly set to pilot location Heat shield not in place Embers or sand covering pilot assembly Low dead batteries No gas flow to the valve Remote too far from receiver Spark ignition interfering with remote signal Clear out obstruction Replace pilot gas supply line if kinked Have gas pressure checked by installer or gas supplier Air should clear attempt to relight Turn on valve 8V models only Check all wires are securely in place Replace batteries Replace the switch box unit or remote system as appropriate Check and replace if necessary Replace with new ones Replace valve Check for low gas pressure should have operating pressures of 7 w c for natural gas 11 w c for propane at manifold Burner should be filled completely with sand or vermiculite Open glass doors See INSTALL THE PILOT ASSEMBLY TO THE BURNER section Place heat shield over valve Be sure the solid black face of the shield is between the valve and the burner Clear all foreign material from around the p
7. AFTER OPERATION DECORATIVE MEDIA REPLACEMENT Refer to the burner instructions for proper replacement of decorative media Rev 1 1306140730 10 D batteries Valve heat shield in place Heat shield Valve heat shield in place Burner pan G45 burner shown Valve and heat shield FIREBOX Valve wire Wire bundles go around bundle the valve and away from the burner IF SWITCH BOX IS INSIDE FIREBOX ORIENT ONLY AS SHOWN BELOW FIREBOX Fig 10 4 Place switch box LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life This appliance is equipped with an ignition device that automatically lights the pilot DO NOT attempt to light the pilot by hand BEFORE OPERATING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS e Do not light any appliance e Do not touch any electric switch do not use any phone in your building e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Use only the supplied standing pilot toggle switch or the control remote system components to light the pilot This valve will not o
8. C The temperature can be displayed in F or C When you first install the batteries the temp indicator at the top of the screen will be flashing Use the Up Down keys to switch between F or C 15 Display screen key Function key OFF DOWN Transmission Room temperature Flame Height Flame icon Timer indicates system is in operation SetTemp Woo er detail Set desired flame level 1 5 Set desired time Room temperature Set desired temperature Flame icon indicates system is in operation Fig 15 5 Thermostat detail MODE D EMPLOI A DISTANCE ORIENTATION Avant la premi re utilisation t l commande allumez l appareil pour la section d clairage distance La t l commande ne fonctionne le syst me de br leur en mode distant Familiarisez vous avec les touches de l metteur et de l affichage comme illustr dans la Fig 16 1 Et Fig 16 2 Identifier les touches de l metteur quatre e SUR OFF TOUCHES Ces touches tourner le syst me sur SUR ou OFF e TOUCHE FONCTION Cette touche lorsque le syst me est activ permet de basculer entre la s lection de deux modes Hauteur de flamme et de la minuterie e TOUCHE TEMPERATURE Cette touche lorsque le syst me est activ est utilis pour r gler la temp rature d sir e via le mode thermostat e UP BAS TOUCHES Dans la hauteur des flammes Minuteur Thermostat Ou le mode la touche ON OF
9. de la temp rature en haut de l cran est la temp rature ambiante en fonction de la t l commande Note Le syst me continue de fonctionner alors que la t l commande est en mode thermostat et la flamme ne s allume et s teint en fonction de la temp rature de consigne L appareil ne peut tre manuellement activ ou d sactiv moins que le mode thermostat est sorti via le bouton Temp TEMPERATURE INDICATOR For C La temp rature peut tre affich e en F ou C Lorsque vous installez les piles l indicateur de temp rature dans la partie sup rieure de l cran se met clignoter Utilisez les touches Haut Bas pour basculer entre F ou C 16 d affichage SUR UP Fonction Temperature Touche OFF BAS Transmission La temperature ambiante Hauteur Ic ne indique flamme que le Minuteur syst me en R glezTemp fonctionnement d tail R glez la hauteur de flamme d sir e de 1 5 R gler l heure d sir e La temp rature ambiante R gler la ball ee L ic ne de flamme indique que le syst me est en fonctionnement Fig 16 5 Thermostat d tail TROUBLESHOOTING PROBLEM CAUSE SOLUTION 1 Pilot will not light No spark at pilot Pilot lights but main burner will not Log set not burning properly Log set shuts down during operation Intermittent ignitor spark during use main burner has been burning for well over a minute Remote control not
10. gas in the unit to dissipate then repeat step 2 above IF Function YOU SMELL GAS SEE STEP B ABOVE key ON UP key remote system components to OFF and contact a qualified OFF DOWN professional service technician key Fig 11 2 Remote transmitter detail 11 INSTRUCTIONS D ALLUMAGE POUR VOTRE SECURITE LISEZ AVANT D ALLUMER AVERTISSEMENT Si vous ne suivez pas ces instructions la lettre un incendie ou une explosion entrainant des dommages materiels des blessures ou des pertes de vie Cet appareil est quip d un dispositif d allumage qui allume automatiquement la veilleuse NE PAS essayer d allumer la veilleuse manuellement AVANT D UTILISER Sentez tout autour de l appareil pour le gaz Assurez vous de sentir pr s du plancher car certains gaz sont plus lourds que l air et se d posent sur le sol QUE FAIRE SI UNE ODEUR DE GAZ e Ne pas allumer l appareil e Ne touchez aucun interrupteur lectrique n utilisez aucun t l phone dans votre b timent e Appelez imm diatement votre fournisseur de gaz partir du t l phone d un voisin Suivez les instructions du fournisseur de gaz Si vous ne pouvez joindre votre fournisseur de gaz appeler les pompiers Utilisez uniquement le commutateur bascule fourni veilleuse permanente ou la commande composants du syst me distance pour allumer la veilleuse Cette vanne ne fonctionne pas si le pilote n est pas allum et stable Ne pas utiliser c
11. will show all active icons on the screen FLAME HEIGHT Five flame height levels are available Press the Function key to index to the Flame Height mode A number 1 5 will be displayed at the bottom of the screen See Fig 15 3 Pressing the Up Down keys once will increase decrease the flame height by 1 of 5 increments TIMER In Timer Mode the unit will remain functioning until the set amount of time has expired Press the Function key to index to the Timer mode Pressing the Up Down keys once in this mode will increase decrease the set time in increments of 10 minutes See Fig 15 4 To turn off the timer mode press the OFF key This will turn off the unit THERMOSTAT In Thermostat Mode the unit will remain functioning until the room temperature increases 4 F above the Set Point Temperature It will turn back on at 4 F below the Set Point Temperature Press the Temp key so the Set Temperature is displayed bottom of screen See Fig 15 5 Pressing the Up Down keys once in this mode will increase decrease the set temperature Note that the temperature display on the top of the screen is the room temperature according to the remote transmitter Note The system remains in operation while the remote is in Thermostat Mode and the flame will only turn on and off according to the set temperature The unit cannot be manually turned on or off unless the Thermostat Mode is exited via the Temp button TEMPERATURE INDICATOR For
12. EMOTE TRANSMITTER BATTERY 10 INSTALL REPLACE SWITCH BOX BATTERIES 10 HEAT SHIELD PLACEMENT 10 SWITCH BOX PLACEMENT 10 DECORATIVE MEDIA REPLACEMENT 11 LIGHTING INSTRUCTIONS 11 REMOTE LIGHTING 13 MANUAL LIGHTING 13 PILOT APPEARANCE 13 SHUTTING DOWN 15 REMOTE OPERATING INSTRUCTIONS 15 ORIENTATION 15 FLAME HEIGHT 15 TIMER 15 THERMOSTAT 15 TEMPERATURE INDICATOR FOR C 17 TROUBLESHOOTING 17 SYNCING THE REMOTE 18 NOTES PAGE 19 ELECTRONIC PILOT TROUBLESHOOTING 02V ONLY 20 WARRANTY Rev 1 1306140730 3 L A2 352 IMPORTANT INFORMATION CHECK TO BE SURE THAT THE PROPER FUEL GAS IS BEING USED WITH THIS PILOT KIT The installation including provisions for combustion and ventilation air must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI 2223 1 NFPA 54 This component and its individual shutoff valve must be disconnected from the gas supply piping system when testing at pressures that exceed 1 2 psig This is accomplished by closing the gas supply line valve This component must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any testing of the gas supply system at test pressures up to and including 1 9 psig A fireplace screen must be in place when the gas burner system is in operation Unless other provisions for combustion air are provided the screen shall have an opening s for introduction of combustion air WHE
13. F touches deviennent touches HAUT BAS pour augmenter ou diminuer la hauteur de la flamme le montant minuterie ou la temp rature de point de consigne L cran affichera toutes les ic nes actives sur l cran HAUTEUR DE LA FLAMME Cinq niveaux de hauteur de flamme sont disponibles Appuyez sur la touche de fonction l index en mode hauteur de la flamme Un certain nombre de 1 5 appara t au bas de l cran Voir Fig 16 3 Cl s les touches Haut Bas fois pour augmenter diminuer la hauteur de la flamme par 1 de 5 incr ments MINUTEUR En mode chronom tre l unit restera jusqu ce que le fonctionnement montant fix de temps a expir Appuyez sur la touche de fonction l index de la mode minuterie En appuyant sur les touches Haut Bas fois dans ce mode pour augmenter diminuer l heure r gl e par increments de 10 minutes Voir Fig 16 4 Pour d sactiver le mode de minuterie appuyez sur la touche OFF Cela permettra d teindre l appareil THERMOSTAT En mode thermostat l unit restera fonctionne jusqu ce que la temp rature ambiante augmente de 4 F au dessus de la temp rature de consigne Il se remettra en marche 4 F en dessous de la temp rature de consigne Appuyez sur la touche Temp de sorte que la temp rature de consigne est affich e en bas de l cran Voir Fig 16 5 En appuyant sur les touches Haut Bas fois dans ce mode pour augmenter diminuerla temperature de consigne Notons que l affichage
14. KITS DE PILOTES AVERTISSEMENT Important Lire attentivement ces instructions Si les informations contenues dans ce manuel avant de commencer l installation du ne sont pas suivies la lettre un incendie ou syst me de contr le du br leur une explosion pourraient s ensuivre causant des dommages mat riels des blessures ou des l l i MA pertes de vie La Peterson r el Fyre syst me de brileur doit tre install uniquement dans un foyer a combustible solide Ne pas entreposer ni utiliser d essence ou qui br le avec une chemin e de travail construite en d autres vapeurs et liquides inflammables mat riaux incombustibles Les combustibles solides proximit de cet appareil ou de tout autre ne doit pas tre br l dans un foyer o l appareil QUE FAIRE SI UNE ODEUR DE GAZ est install L installation y compris les dispositions l pour la combustion l air de ventilation et d a ration Ouvrez une fen tre minimale requise ouverture permanente doivent e Ne pas tenter d allumer d appareil tre conformes au Code national du gaz combustible e Ne touchez aucun interrupteur ANSI 2223 1 NFPA 54 et aux codes du b timent lectrique n utilisez aucun t l phone locaux Au Canada l installation doit tre conforme dans le b timent avec le stockage de gaz naturel et propane et le code Appeler imm diatement le fournisseur d installation de manutention CSA B 149 1 Un collier de gaz partir du t l ph
15. N GLASS FIREPLACE ENCLOSURES DOORS ARE USED OPERATE THE BURNER SYSTEM WITH THE GLASS DOORS FULLY OPEN BOTH SIDES IF THE FIREPLACE IS A SEE THROUGH TYPE This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes Installation of appliances designed for manufactured homes or mobile homes must conform with Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the U S or with CAN CSA 2240 MH in Canada or with ANSI NCSBCS A225 1 NFPA 501A Manufactured Home Installations Standard when such as standard is not applicable Do not use this appliance if any part has been underwater Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater Rev 1 1306140730 4 L A2 352 WIRING DIAGRAM EPK 2V Wiring Diagram fes DRE Pilot Igniter Ignition a assembly module pack Wire harness A D cell l Batteries NES EEE DK NI e l fot COS a ates Switch Battery pack EPK 3V Wiring Diagram Pilot Igniter assembly Ignition module pack 7 Wire harness l D cell l Batteries ONG ee GR to Switch i Battery pack ae Fig 5 1 SPECIFICATIONS Minimum firebox dimensions required for burner system with EPK valve attached Min Firebox Dimensions Can akasi 16 19 31 39
16. RH PETERSON co A real 7 OWNER S MANUAL PREMIUM GAS LOGS ELECTRONIC PILOT KIT INTERMITTENT SPARK Models IGNITION PILOT EPK 2V P d 1 2 EPK 3V P REMOTE OR MANUAL ire OPERATION BATTERY OPERATION AV mor eragown VARIABLE FLAME HEIGHT CONTROL Suitable for G4 and G45 series burners EPK 2V 3V PILOT KITS WARNING Important Read these instructions carefully aaa before starting installation of the If the information in this manual is not followed burner control system exactly a fire or explosion may result causing property damage personal injury or loss oflife The Peterson Real Fyre burner system is to be Do not store or use gasoline or other installed only in a solid fuel burning fireplace with a flammable vapors and liquids in the vicinit working flue constructed of noncombustible material o eor io te hr sr y Solid fuels shall not be burned in a fireplace where the unit is installed The installation including provisions WHAT TO DO IF YOU SMELL GAS for combustion ventilation air and required minimum Open a window permanent vent opening must conform with the National Fuel Gas Code ANSI 2223 1 NFPA 54 and applicable local building codes In Canada the installation must conform with the Natural Gas and Propane Storage and Handling Installation Code Immediately call the gas supplier from CSA B 149 1 A damper stop clamp is included to a neighbor s phone and follow the gas maintain the minimu
17. at the factory see Fig 13 2 If the pilot flame burns incorrectly shut down completely and contact a qualified professional service technician SHUTTING DOWN e For a remote shut down press the OFF button on the remote transmitter e For a manual shutdown or if your remote is lost press the switch on the switch box to the OFF position 13 REMOTE Fig 13 1 Switch box switch detail ro ai Fig 13 2 Proper pilot flame INSTRUCTIONS D ALLUMAGE cont ALLUMAGE MANUEL ATTENTION NE PAS essayer d allumer la veilleuse manuellement 1 Localisez le commutateur 3 positions sur le bo tier de commande voir Fig 14 1 Appuyez sur l interrupteur sur la position ON Le recepteur de la telecommande emettra un bip sonore puis l allumeur commence a susciter Apres les veilleuses et est tablie la vanne s ouvre automatiquement et le br leur s allume Note La s quence d allumage dure environ 5 secondes WARNING Si le pilote ne s allume pas dans les 10 secondes teignez le syst me Attendez cinq 5 minutes pour n importe quel gaz dans l unit se dissiper puis r p tez l tape 2 ci dessus S IL YA UNE ODEUR DE GAZ voir l tape B CI DESSUS Si le pilote ne s allume pas apr s plusieurs essais mettez le syst me hors tension et contactez un technicien qualifi Note En mode manuel la t l commande ne fonctionne pas du syst me de br leur ASPECT PILOTE V rifiez p ri
18. ed TO REGISTER YOUR PRODUCT ONLINE GO TO WWW RHPETERSON COM AND CLICK ON PRODUCT REGISTRATION THANK YOU FOR YOUR PURCHASE Quality Check Leak Test Burn Test Gas Type Nat L P Inspector Robert H Peterson Co 0 14724 East Proctor Avenue City of Industry CA 91746 20
19. erformance and full benefit from the burner system and safety pilot system These instructions must be used as a supplement to the instructions supplied with the Peterson burner system Follow the burner system instructions and make adjustments as appropriate for the addition of a safety pilot system Use gas pipe sealing compound that is resistant to all gasses or Teflon tape and apply to all male pipe connections Make sure that all connections are tight INSTALLATION The valve system is shipped pre assembled for easy installation onto the burner pan Note Installation is easier when done outside of the fireplace PREPARATION If the burner that the valve system is to be added to is already installed remove all decorative media set aside to be reinstalled later and disconnect the flex connector from the burner pan using the instructions that came with the original burner INSTALL PILOT MOUNTING BRACKET The pilotassembly comes with an L shaped mounting bracket Remove the two phillips screws holding the bracket in place then use them to fasten the bracket to burner pan short side toward the back of the pan using the pre drilled holes in the pan see Fig 8 1 INSTALL THE VALVE 1 Apply gas pipe sealing compound or Teflon tape to the male end of the fuel injector or air mixer on the burner 2 Attach the adapter pre assembled to valve to the fuel injector or air mixer by screwing the pan onto the adapter Fig
20. et appareil si une partie quelconque a t submerg e Appelez imm diatement un technicien de service qualifi pour inspecter l appareil et pour remplacer toute pi ce du syst me de contr le et toute commande de gaz qui a t sous l eau Tentative d op ration peut entra ner un incendie ou une explosion entra nant des dommages mat riels des blessures ou des pertes de vie DISTANCE DE L CLAIRAGE ATTENTION NE PAS essayer d allumer la veilleuse Note Step 1 may not be required if previously done during 1 manuellement an earlier lighting Localisez le commutateur 3 positions sur le bo tier de commande voir Fig 12 1 Appuyez sur l interrupteur la position REMOTE Localisez lat l commande etappuvez sur le bouton ON DISTANCE voir Fig 12 2 La s quence d allumage commencera Le r cepteur de la t l commande mettra un bip sonore puis l allumeur commence susciter Apr s les veilleuses et est tablie la vanne s ouvre Fig 12 1 Bo te de contr le d tail interrupteur automatiquement et le br leur s allume Choisissez le r glage souhait s avec la t l commande Voir la section INSTRUCTIONS DE FONCTIONNEMENT A DISTANCE pour plus de d tails Ecran d affichage Note La s quence d allumage dure environ 5 secondes AVERTISSEMENT Si le pilote ne s allume pas dans les 10 secondes appuyez sur le bouton Touche OFF de la t l commande ou d placez SUR UP l interrupteur la position OFF
21. ilot assembly Check and replace Check gas supply to valve Move remote closer to receiver Move remote closer to receiver Periodically inspect the pilot assembly and valve controls and maintain them free of obstruction or debris If the pilot flame is not blue with possibly yellow tips and does not impinge on the electrodes or if the pilot does not stay lit contact a qualified professional service technician to service the pilot system SYNCING THE REMOTE The ignition module pack has a pinhole sync button located next to the LED light see Fig 17 1 Simultaneously press the sync button with a paperclip The codes below are a guide if the ignition 1 Flash module pack is flashing the red LED lights RED LED TROUBLE CODES or similar object and the ON button on the remote Nat LP selector not in correct position a i SYNC button Gh ME 2 Flashes HI voltage coil failure no spark 3 Flashes Shorted sensor no gas flow no ignition of pilot in 60 seconds 17 NOTES PAGE Please use this page to record any information that you may want to have at hand 18 ELECTRONIC PILOT TROUBLESHOOTING 02V ONLY Detail A Electrode A When adjusting the spark electrode if necessary NEVER adjust the electrode by bending the wire ALWAYS adjust the electrode by loosening the retainer nut s then adjust accordingly The minimum gap between the spark electrode sensor electrode and the pilot flame hood is
22. m permanent vent opening and to suppliers instructions prevent full closure of the damper blade The chimney If you cannot reach the gas supplier damper must be fixed fully opened when burning call the fire department the unit The burner system is designed to burn Installation and service must be with yellow flames thus adequate ventilation is performed by an NFI Certified or other absolutely necessary qualified professional installer service agency or the gas supplier Do not try to light any appliance Do not touch any electrical switch do not use any phone in the building NATIONAL FIREPLACE We recommend that our gas INSTITUTE hearth products be installed ad and serviced by profes sionals who are certified in the U S by the National Fireplace Institute NFI as CERTIFIED NFI Gas Specialists INSTALLER amp CONSUMER These instructions MUST be retained with this appliance Robert H Peterson Co 9 14724 East Proctor Avenue 2 City of Industry California 91746 Rev 1 1306140730 1 L A2 352 SPETERSON KG INSTALLATION amp br gal MODE D EMPLOI PREMIUM GAS LOGS KIT PILOTE ELECTRONIQUE MST PILOTE D ALLUMAGE Mod les D om AN TaS INTERMITTENT SPARK EPK 2V P 22 nibs sf FONCTIONNEMENT EPK 3V P ooa DISTANCE OU MANUEL FONCTIONNEMENT SUR BATTERIE FLAMME VARIABLE CONTROLE DE HAUTEUR 2V mod le pr sent Convient pour les G4 et G45 br leurs de la s rie EPK 2V 3V
23. odiquementle pilote pour le mod le dela flamme La flamme de la veilleuse devrait encercler la pointe du g n rateur et est pr r gl en usine voir Fig 14 2 Si la flamme de la veilleuse br le mal compl tement arr t et contacter un technicien de service qualifi TEINDRE e Pour un arr t distance appuyez sur le bouton OFF de la t l commande e Pour un arr t manuel ou si votre t l commande est perdue appuyez sur l interrupteur sur le bo tier de commande la position OFF 14 DISTANCE Fig 14 1 Bo te de contr le d tail interrupteur lu Fig 14 2 Une bonne flamme de la veilleuse REMOTE OPERATING INSTRUCTIONS ORIENTATION Prior to remote transmitter use light the appliance per the REMOTE LIGHTING section The remote will only operate the burner system in remote mode Familiarize yourself with the transmitter keys and display as illustrated in Fig 15 1 and Fig 15 2 Identify the four transmitter keys e ON OFF KEYS These keys turn the system ON or OFF e FUNCTION KEY This key when the system is on will toggle between the selection of two modes Flame Height and Timer e TEMP KEY This key when the system is on is used to set the desired temperature via the Thermostat mode e UP DOWN KEYS In Flame Height Timer Or Thermostat mode the ON OFF keys become UP DOWN keys to increase or decrease the Flame Height Timer amount or Set Point Temperature The display
24. one d un voisin d arr t d amortissement est inclus pour maintenir et suivez les instructions du fournisseur l ouverture de ventilation minimum permanent et pour de gaz emp cher la fermeture compl te du clapet Le registre de chemin e doit tre fix compl tement ouvert lors de la combustion de l appareil Le syst me de bruleur est con u pour bruler avec des flammes jaunes ainsi une ventilation ad quate est absolument n cessaire Installation et l entretien doivent tre effectu s par une personne certifi e NFI ou un autre installateur professionnel qualifi une agence de service ou le fournisseur de gaz NATIONAL FIREPLACE We recommend that our gas INSTITUTE hearth products be installed INSTALLATEUR ET DE CONSOMMATION A crate whats Dadin Ces instructions doivent tre conserv es the U S by the National L Fireplace Institute NFI as avec l appareil CERTIFIED NFI Gas Specialists Robert H Peterson Co 9 14724 East Proctor Avenue 2 City of Industry California 91746 Rev 1 1306140730 2 L A2 352 TABLE OF CONTENTS 3 TABLE OF CONTENTS 4 IMPORTANT INFORMATION 5 WIRING DIAGRAM 5 SPECIFICATIONS 6 REPLACEMENT PARTS LIST 2V MODEL 7 REPLACEMENT PARTS LIST 3V MODEL 8 INSTALLATION 8 PREPARATION 8 INSTALL PILOT MOUNTING BRACKET 8 INSTALL THE VALVE 8 INSTALL THE FLAME DIVERTER BRACKET 9 INSTALL THE PILOT IGNITER ASSEMBLY TO THE BURNER 9 CONNECT TO THE GAS SUPPLY 9 LEAK TEST 10 INSTALL REPLACE R
25. perate if the pilot is not lit and stable Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Attempted operation may result in fire or explosion resulting in property damage personal injury or loss of life REMOTE LIGHTING CAUTION DO NOT attempt to light the pilot by hand Note Step 1 may not be required if previously done during 1 Note The ignition sequence will take approximately 5 an earlier lighting Locate the 3 position switch on the switch box see Fig 11 1 Press the switch to the REMOTE position Locate the remote transmitter and press the ON button see Fig 11 2 The ignition sequence will begin The remote receiver will emit an audible beep then REMOTE the igniter will begin to spark After the pilot lights and is established the valve will automatically open and the burner will light Adjust to the desired setting s with the remote transmitter See the REMOTE OPERATING Fig 11 1 Switch box switch detail INSTRUCTIONS section for details seconds Display WARNING If the pilot fails to light within 10 seconds screen If the pilot fails to light after several tries turn all control press the OFF button on the remote transmitter or move the switch to the OFF position to turn OFF the system Allow five 5 minutes for any
26. pour teindre le syst me Attendez cinq Touche a 5 minutes pour n importe quel Temp rature gaz dans l unit se dissiper puis r p tez l tape 2 ci dessus S IL YA Touche UNE ODEUR DE GAZ voir l tape B OFF BAS Si le pilote ne s allume pas apr s plusieurs essais tournez CI DESSUS Fig 12 2 D tail t l commande tout contr le composants du syst me distance sur OFF et contactez un technicien qualifi 12 LIGHTING INSTRUCTIONS cont MANUAL LIGHTING CAUTION DO NOT attempt to light the pilot by hand 1 Locate the 3 position switch on the switch box see Fig 13 1 Press the switch to the ON position The remote receiver will emit an audible beep then the igniter will begin to spark After the pilot lights and is established the valve will automatically open and the burner will light Note The ignition sequence will take approximately 5 seconds WARNING If the pilot fails to light within 10 seconds turn OFF the system Allow five 5 minutes for any gas in the unit to dissipate then repeat step 2 above IF YOU SMELL GAS SEE STEP B ABOVE If the pilot fails to light after several tries turn the system OFF and contact a qualified professional service technician Note In manual mode the remote transmitter will not operate the burner system PILOT APPEARANCE Periodically check the pilot for proper flame pattern The pilot flame should encircle the generator tip and is preset
27. rtment Replace the old batteries with 4 new D batteries See Fig 10 1 When battery replacement is complete properly place the switch box in the the fireplace as instructed in this manual Important Low dead batteries will affect burner system operation Replace batteries any time the burner will not turn on HEAT SHIELD PLACEMENT Cover the valve with the heat shield as shown in Fig 10 2 or Fig 10 3 The heat shield must remain in place over the valve at all times during operation Keep the area above the heat shield clear of decorative media or any other object Important Ensure the pilot supply tube does not interfere with heat shield placement For 2V models the tube will come out of the rear and coil back to the pilot For 3V models the tube will come out of the left side of the heatshield and coil to the pilot SWITCH BOX PLACEMENT Place the switch box outside of the firebox and a minimum of 6 from the burner flame If the switch box is in the firebox the switch box must only be oriented as shown in Fig 10 4 The switch box must not be placed in the rear of the fireplace or in any other manner than shown in Fig 10 4 Set the box on its side and place the bottom of the box toward the right firebox wall box must be a minimum of 6 from the burner flame Be sure that the pilot and valve wire bundles remain clear of the burner valve and heat shield at all times CAUTION THE SWITCH BOX MAY BE HOT DURING AND
28. se Teflon tape or pipe compound Tighten securely Discard the smaller connector adapter from the connector kit as this is not needed Attach the flex connector to the adapter on the valve 3 Connect the flex connector to the adapter on the gas stub Tighten both ends securely 4 Follow the instructions supplied with the Peterson burner system for proper burner placement Note The burner should be centered in the fireplace LEAK TEST Turn on the fireplace gas supply and test at all connections for leaks using the appropriate soapy water solution If bubbles appear a leak is present Turn off the gas and tighten at all connections Repeat until no leaks are present If a leak persists turn off the gas supply and contact the local gas company or dealer NEVER USE A FLAME TO CHECK FOR LEAKS Fig 9 3 3V models Attach flex to valve Rev 1 1306140730 9 L A2 352 INSTALLATION Cont INSTALL REPLACE REMOTE TRANSMITTER BATTERY CAUTION ENSURE THE UNIT IS CONNECTED TO THE GAS LINE AND HAS BEEN TESTED FOR LEAKS BEFORE YOU INSERT BATTERIES To access the battery slide open the lid found on the back of the remote transmitter Replace the old batteries with 3 new AAA batteries Re secure the lid INSTALL REPLACE SWITCH BOX BATTERIES To access the batteries locate the switch box and turn it over Use a Phillips screwdriver to remove the screw found on the back of the switch box then remove the battery compa