User Manual - LaserStreet.com

image

Contents

1.
2. The device can calculate distances using a two point Pythagoras theorem This method is useful when the distance to be measured is difficult or dangerous to access sure you strictly follow the sequence of the measurements All target points need to be vertically or horizon tally in the same plane Best results can be expected if the device is turned around a fixed point e Itis possible to use the Minimum maximum measuring by pressing the ON MEASURING key A 1 longer The minimum value is used for the measurements perpendicular towards the target See figure I Press the AREA VOLUME INDIRECT MEASURE MENT key A 3 three times The Corresponding symbol B 6 appears in the display The distance to be measured will flash in the display Take the neces sary measurements The result and the single measurements appear on the display Cg Right angle is necessary for the second measurement use Minimum maximum measuring as explained Functions az ina Stanley TLM 200 1 0 0 gb Appendix Message Codes All message codes will be displayed with either InFo or Error Technical Data Range use target plate from 70 m 230 ft onwards 0 05 m to 30m 0 2 ft to 100 ft Measurin to 30m accuracy up 2 c standard typ 3 mm 1 8 max 5 mm 1 5 The following mistakes can be corrected
3. Sustracci n Efectuar la primera medici n La adici n se lleva a cabo al pulsar la tecla M S A 2 y la substracci n al pulsar la tecla MENOS A 7 Posteriormente efect e la siguiente medici n Este proceso se puede repetir cuantas veces sea necesario El resultado se visualiza en el indicador principal as como el valor de la ultima medici n Al pulsar la tecla BORRAR APAGADO A 5 se cancela la ltima operaci n Utilizando el mismo procedimiento es posible sumar y restar superficies y vol menes Superficie Pulsar la tecla SUPERFICIE VOLUMEN FUNCIONES DE PIT GORAS A 3 El s mbolo correspondiente B 5 aparece en la pantalla El primer lado que se debe medir se muestra intermitente en la pantalla Tomar las dos medidas En la pantalla se muestra el resultado en el indicador principal Volumen Pulsar dos veces la tecla SUPERFICIE VOLUMEN FUNCIONES DE PIT GORAS A 3 El s mbolo correspondiente B 5 aparece en la pantalla La primera distancia que se debe medir se muestra intermitente en la pantalla Despu s de tomar las tres mediciones que se deben efectuar en la pantalla se muestra el resultado en el indicador principal Funciones de Pit goras El instrumento puede calcular distancias aplicando el Teorema de Pit goras Este m todo resulta til cuando los procedimientos para medici n de distan cias resulten dif ciles o arriesgados e Es absolutamente imprescindible efectuar las
4. salet s avec un chiffon humide doux Ne pas utiliser des produits de nettoyage ou solvants agressifs Traiter l instrument avec les m mes pr cautions que des jumelles ou une cam ra Garantie Le Stanley TLM 200 est garanti un 1 an par Stanley Works Pour plus d informations sur la garantie veuillez consulter le site www stanleyworks com Si vous avez des questions sur la garantie veuillez contacter le revendeur chez qui vous avez achet l instrument Les illustrations descriptions et caract ristiques techniques sont sans engagement de notre part et peuvent tre modifi es sans pr avis Annexe 6 TI Stanley TLM 200 1 0 0 f Manual de empleo Versi n 1 0 Espafiol Colocar Sustituir las pilas V ase la figura C Empujar la de cierre Nuestra felicitaci n por la compra de su equipo hacia la derecha y abrir el compartimento de las pilas Stanley TLM 200 empujando hacia abajo la tapa Colocar las pilas en el Las instrucciones de seguridad en compartimento revisando que se inserten por A un documento separado fornan completo Introducir la tapa del compartimento parte del Manual de empleo Lea presionando hasta que quede bien encajada detenidamente las instrucciones de E s mbolo de la bater a B 4 se mostrar seguridad y el Manual de empleo antes de empezar a intermitente en la pantalla cuando las pilas est n trabajar con su nuevo equipo bajas Las pilas deben sustitu
5. Key Pushing the CLEAR OFF key A 5 clears the last entry or measurement Within a function area volume etc single measurements can be deleted step by step and re measured Illumination The display backlight remains on for 15 seconds after the last key press Reference Setting The default reference setting is from the rear of the instrument By pressing the MEASUREMENT REFE RENCE key A 6 the setting can be changed so that the next measurement taken will be from the front of the in strument Afterwards the reference setting automatically defaults back to rear See picture D By pressing MEASUREMENT REFERENCE key A 6 long the reference setting will stay from the front of the instrument Repeated pressing of the MEASUREMENT REFERENCE key A 6 will set the instrument to its default reference setting Single Distance Measuring Pressing ON MEASURING key A 1 turns the laser on Aim at the desired target and press ON MEASU Stanley TLM 200 1 0 0 gb RING key A 1 again The measured distance is displayed immediately in the chosen unit Minimum Maximum Measuring This function allows the user to measure the minimum or maximum distance from a fixed measuring point as well as to determine spacing see figure It is commonly used to measure diagonal distances maximum values or horizontal distances minimum value Press and hold ON MEASURING key A 1 until you hear a beep indicating
6. mediciones en la secuencia indicada e Todos los puntos de medici n han de estar situados en el mismo plano de la pared alineados vertical u horizontalmente 105 mejores resultados se obtienen cuando el instru mento se puede girar alrededor de un punto fijo e Es posible utilizar el Tracking m ximo m nimo manteniendo pulsada la tecla ENCENDIDO MEDICI N A 1 El valor de tracking m nimo se utiliza para mediciones perpendiculares al punto de medici n V ase la figura I Pulsar tres veces la tecla SUPERFICIE VOLUMEN FUNCIONES DE PITAGORAS A 3 hasta que aparezca el smbolo correspondiente B 6 en la pantalla La distancia que se debe medir aparecera intermitente en la pantalla Efectuar las mediciones necesarias En la pantalla se visualizarn el resultado y cada una de las mediciones Cg Se requiere que exista un ngulo recto para efectuar la segunda medici n Utilizar la funci n Trac king m ximo m nimo como se explic anteriormente Funciones Sasa Stanley TLM 200 1 0 0 e C digos de mensajes Todos los c digos de mensajes se muestran con el Datos t cnicos Alcance desde 70 m con tablilla de punter a 0 05 ma30m Precisi n de medici n hasta 30 m t p 3 mm 1 8 m x 5 mm 1 5 texto InFo o Error 2 desviaci n t pica Los siguientes errores se pueden corregir Unida
7. pr c dentes 12 Valeur maximale d une mesure continue HM S lection de l unit Presser longuement la touche UNITES A 4 pour r gler l unit Unit s possibles Distance Surface Volume 0 000 m 0 000 m 0 000 m 0 00 m 0 00 m 0 00 m 0 00 ft 0 00 ft 0 00 ft 0 00 1 16 ft in 0 00 ft 0 00 ft 0 o Zh 0 00 ft 0 00 ft 0 0 in 0 00 ft 0 00 ft 0 16 in 0 00 ft 0 00 ft Utilisation Mise sous hors tension ON Presser bri vement la touche ON MESURE A 1 L ic ne pile s affiche jusqu au prochain actionnement d une touche OFF Presser la touche CLEAR OFF A 5 plus longuement L instrument s teint en plus tout seul si aucune touche n est actionn e pendant trois minutes Utilisation EE NEN Stanley TLM 200 1 0 0 f Touche CLEAR Une pression de la touche CLEAR OFF A 5 annule la derni re action En cas d utilisation de la fonction Surface ou Volume les mesures individuelles peuvent tre effac es graduellement et red termin es Eclairage Le r tro clairage reste allum pendant 15 secondes apr s la derni re pression de touche R glage de la r f rence de mesure La r f rence de mesure arri re est le r glage par d faut Presser la touche REFERENCE DE MESURE A 6 pour effectuer une seule mesure partir du bord avant Apr s cette mesure le r glage par d faut r f rence arri re s applique de nouveau Voir
8. s curit dans la brochure en Mise en 5 1 Utilisation 2 Stanley TLM 200 1 0 0 f D Mise en service Mise en service Insertion Remplacement des piles Voir illustration C pousser le bouton de verrouillage droite puis le couvercle du comparti ment piles vers le bas Ouvrir le couvercle du compartiment et introduire les piles en respectant la polarit Repousser ensuite le couvercle du comparti ment vers le haut jusqu ce qu il s enclenche L ic ne pile B 4 clignote en permanence sur l cran quand la charge des piles devient trop faible Remplacer les piles le plus rapidement possible e Respecter la polarit lors de l insertion des piles e Utiliser seulement des piles alcalines e Retirer les piles s il est pr vu de ne pas utiliser le produit pendant une p riode prolong e risque de corrosion Lors d un changement de piles les r glages et valeurs enregistr es restent conserv s Clavier Voir illustration A 1 ON MESURE 2 PLUS 3 SURFACE VOLUME MESURE INDIRECTE PYTHAGORE UNITES CLEAR OFF REFERENCE DE MESURE MOINS Affichage Voir illustration B Information sur mesures incorrectes Laser ON R f rence de mesure avant arri re Ic ne pile Surface Volume Mesure indirecte Pythagore Erreur de mat riel Ligne principale Unit s avec exposants 2 3 O Valeur minimale d une mesure continue 1 Trois lignes additionnelles par ex valeurs
9. 71 920 FatMax User Manual Manuel d utilisation Manual de empleo i Dam tp 00 gg om ABE 05888 id AGRHA AERE m oo 00 00 05 ftim User Manual Version 1 0 English Congratulations on your purchase of a Stanley TLM 200 accompanies this user manual The operation reading through the manual Letters and Numbers in A The safety instructions can be safety instructions along with the Helpful Hint The first and last page including the braces refer to the illustrations found in a separate booklet which user manual should be read carefully before initial pictures should be folded out and left open whilst Content rige 1 er rm 2 MNCS SUNS goo 3 Functions Appendix Stanley TLM 200 1 0 0 gb Start up Inserting Replacing Batteries See figure C Push locking mechanism to the right and push the cover of the battery compartment downwards and open it Place the batteries in the compartment making sure they are correctly inserted Push the cover of the compartment back and let it lock in place The battery symbol B 4 appears permanently blinking in the display when the battery voltage is too low The batteries should be replaced as soon as possible attention to correct polarity e
10. Use alkaline batteries Batteries should be removed if the device will not be used for a long time danger of corrosion When changing the batteries the settings and stack content remain unchanged Start up Keypad See figure A 1 2 3 NOW ON MEASURING PLUS AREA VOLUME INDIRECT MEASUREMENT PYTHAGORAS UNITS CLEAR OFF MEASUREMENT REFERENCE MINUS Display See figure B Information about faulty measurement Laser ON Measurement reference front rear Battery indication Area Volume Indirect measurement Pythagoras Hardware error Main line Units with exponents 2 3 10 Minimum value of continuous measurement 11 Three auxiliary lines e g previous values 12 Maximum value of continuous measurement Operation Selecting Units Press UNITS key A 4 long to select desired unit Possible units Distance Area Volume 0 000 m 0 000 m 0 000 m 0 00 m 0 00 m 0 00 m 0 00 ft 0 00 ft 0 00 ft 0 00 1 16 ft in 0 00 ft 0 00 ft 0 0 1 16 0 00 2 0 00 ft 0 0 in 0 00 ft 0 00 ft 0 4 46 in 0 00 ft 0 00 ft Switching On Off ON OFF Press ON MEASURING key A 1 briefly Battery indication is displayed until the next keystroke Press and hold CLEAR OFF key A 5 To maximize battery life the device will automat ically turn off after 3 minutes of inactivity Stanley TLM 200 1 0 0 gb CLEAR
11. a quede en la sombra el alcance de medici n sin tablilla de punter a se incrementa Utilizar una tablilla de punter a para aumentar el alcance de medici n al trabajar con luz de d a o si el objeto a medir tiene mala reflexi n Superficies de medici n Se pueden presentar errores en la medici n al medir hacia superficies liquidas incoloras como el agua o hacia vidrios libres de polvo poliestireno aislante o superficies semi permeables similares Al apuntar hacia superficies muy brillantes se desv a el rayo l ser lo que puede provocar errores de medi ci n El tiempo de medici n se puede incrementar al apuntar hacia superficies no reflectantes y oscuras Cuidado No sumergir la unidad en el agua Limpiarla con un pano limpio y suave No utilizar limpiadores agresivos Limpiar las superficies pticas con esmero como si se tratara de unas gafas un aparato fotogr fico o unos prism ticos Garant a Stanley Works ofrece a sus clientes una garant a de un 1 a o en los equipos Stanley TLM 200 Para mayor informaci n de la garant a consultar www stanleyworks com En caso de dudas acerca de la garant a contactar con el distribuidor local con el cual adquiri el instru mento Todas las ilustraciones descripciones y especifica ciones t cnicas est n sujetas a modificaci n sin previo aviso Ap ndice EN EN Stanley TLM 200 1 0 0 e STANLEY MAKE SOMETHING GREAT 7 4 6 6 5 2 A
12. d m nima visualizada 1 1 16 InFo Causa Soluci n Clasificaci n l ser Il 204 Error en el c lculo Repetir el procedi Tipo l ser 635 nm 1 mW miento O punto l ser 6 30 mm 252 Temperatura muy alta Enfriar el instrumento en distancia 10 30 m 253 Temperatura muy baja Calentar el instrumento Apagado autom tico despu s de 180 seg 255 Se al de recepci n Utilizar la tablilla de Pantalla LCD Y muy d bil tiempo de punteria luminaci 7 medici n muy largo aminacion 256 Se al de recepci n Utilizar la tablilla de Medici n continua demasiado potente punter a tracking lado gris Calculadora Y 257 Ed de mrs Utilizar la tablilla de Constantes Y 19 iu n SUME IG iren Duraci n de las pilas Hasta 10 000 medi Tipo AAA 2x 1 5 V ciones 260 Se interrumpi el rayo Repetir la medici n l ser Protecci n frente agua y IP 54 seg n IEC529 polvo protegido frente a salpi Error Causa Soluci n caduras y polvo Error de hardware Encender y apagar Dimensiones y peso 135x55x34 mm 160 g No varias veces el instru Rango de temperaturas mento Mel el almacenaje 25 C a 70 C 13 F a 158 F apareciendo En caso funcionamiento 10 C a 50 C afirmativo llamar a 14 F a 122 F Soporte t cnico Stanley TLM 200 1 0 0 e E l Ap ndice Condiciones de medici n Alcance de medici n Al trabajar de noche en entornos con polvo y cuando la tablilla de punter
13. deviation Smallest unit displayed 1mm 1 16 InFo Cause Remedy L i T 204 Calculation error Repeat procedure ees 252 Temperature too down instrument Laser type 635 lt 1 mW high O laser spot 6 30 mm 253 Temperatur too low Warm up instrument at distance 10 30 m 255 Receiver signal too Use target plate Automatic switch off after 180 s weak measurement LCD display y time toolong Illumination Y 256 Received signal too Use target plate powerful grey side Continuous Measuring Y 257 Wrong measure Use target plate Calculation Y ment ambient brown side Battery life up to 10 000 brightness too high Type AAA 2x 1 5 V measurements 260 Laser beam inter Repeat measurement IP rating IP 54 acc IEC529 rupted splash proof dust proof Error Cause Remedy Dimension and weight 135x55x34 mm 160 g Hardware error Switch on off the Temperature range e device several times Storage 25 C to 70 C and check if the 13 F to 158 F symbol still appears If Operating 10 C to 50 C SO please call your 14 F to 122 F dealer for assistance Stanley TLM 200 1 0 0 gb E l Appendix Measuring Conditions Measuring Range At night at dusk and when the target is shadowed the measuring range without target plate is increased Use a target plate to increase the measurement range during daylight or if the target has a bad reflec tion Measuring Surfaces Measuring errors can occ
14. e face grise Mesure Minimum 257 Mesure incorrecte Utiliser la plaque de Maximum Y Trop forte lumino mire face marron Fonction de calcul Y A M moire Stack v 19 260 Faisceau laser R p ter la mesure interrompu Dur e de vie des piles jusqu 10 000 mesures type AAA 2x 1 5 V Error Cause Solution Protection contre l eau et IP 54 selon IEC529 Erreur de mat riel Si ce message _ la poussi re tanche au ruissellement e continue s afficher la poussi re Ne Dimensions et poids 135x55x34 mm 160 g l instrument est Plage de temp rature d fectueux Appeler Stockage 25 C 70 C dans ce cas le reven 13 F 158 F deur Service 10 C 50 C 14 F a 122 F Stanley TLM 200 1 0 0 f mE RJ Annexe Conditions de mesure Port e La nuit au cr puscule ou quand le point vis se trouve l ombre la port e augmente sans plaque de mire Utiliser une plaque de mire le jour ou si le point vis a de mauvaises capacit s de r flexion Surfaces vis es Pour viter des erreurs de mesure ne pas viser des liquides incolores par ex de l eau du verre sans poussi re du polystyr ne expans ou des surfaces d un niveau de transparence similaire En cas de vis e de surfaces fortement r fl chis santes le faisceau laser peut tre d vi et des erreurs de mesure peuvent se produire Entretien Ne plonger jamais l instrument dans l eau Enlever les
15. e princi pale alors que les mesures individuelles apparaissent dans les zones d affichage additionnelles Presser la touche CLEAR OFF A 5 pour annuler la derni re op ration On peut proc der de la m me facon pour addi tionner soustraire des surfaces et volumes Stanley TLM 200 1 0 0 f EE SEEN Mesure Surface Presser la touche SURFACE VOLUME MESURE INDI RECTE A 3 L ic ne correspondante B 5 s affiche Le premier c t mesurer clignote Effec tuer les deux mesures requises Le r sultat s affiche sur la ligne principale Volume Presser deux fois la touche SURFACE VOLUME MESURE INDIRECTE A 3 L ic ne correspondante B 5 s affiche La premi re distance mesurer clignote Effectuer les trois mesures requises Le r sultat s affiche sur la ligne principale Mesure indirecte Pythagore L instrument peut calculer des distances au moyen du th or me de Pythagore avec deux points Cette m thode est utile quand la distance mesurer est difficile atteindre ou qu il est dangereux d effectuer une mesure directe __ S assurer de suivre strictement l ordre de mesure prescrit e Tous les points cibles doivent tre verticalement ou horizontalement dans le m me plan On obtient les meilleurs r sultats en faisant tourner l instrument autour d un point fixe e Il est possible d utiliser la fonction Mesure minimum maximum en pressant la touche ON MESURE A 1 longuement La valeur minimale es
16. illustration D Presser la touche REFERENCE DE MESURE A 6 longuement pour mesurer durable ment partir du bord avant R appuyer sur la touche REFERENCE DE MESURE A 6 pour configurer la r f rence sur la valeur par d faut Mesure de distance simple Presser la touche ON MESURE A 1 pour activer le laser Une deuxi me pression d clenche la mesure de distance Le r sultat s affiche imm diatement Mesure Minimum Maximum Cette fonction permet de d terminer la distance minimale maximale d un certain point de mesure et de reporter des distances Voir illustration E La d termination de diagonales valeur maximale ou de distances horizontales valeur minimale sont des applications possibles Presser la touche ON MESURE A 1 et la maintenir enfonc e jusqu l mission d un bip Balayer ensuite l endroit mesurer avec le laser voir figures F G par ex un coin de piece R appuyer sur la touche ON MESURE A 1 pour arr ter la mesure continue Les valeurs minimale maximale correspondantes s affichent de m me que la derni re valeur mesur e sur la ligne principale Fonctions Addition Soustraction Mesurer la premi re distance Une addition s effectue par actionnement de la touche PLUS A 2 une soustraction par actionnement de la touche MOINS A 7 Mesurer ensuite la prochaine distance R p ter cette proc dure autant de fois que n ces saire Le r sultat s affiche toujours sur la lign
17. irse lo m s pronto Indicaci n pr ctica Para facilitar la lectura del posible manual doble hacia adentro la primera y ultima Colocar las pilas por el lado correcto pagina con inclusi n de las fotograf as Las letras y Utilizar s lo pilas alcalinas n meros que se muestran entre llaves hacen refe Parar evitar el peligro de corrosi n se deben rencia a las ilustraciones retirar las pilas del equipo en caso de no utilizarlo 7 durante un periodo largo Ind ice Los parametros y la pila de memoria del equipo no se m modifican en el momento de sustituir las pilas PR Manejo Medir Funciones AD NAICR E 5 Stanley TLM 200 1 0 0 e Iniciar Teclado V ase la figura A 1 ENCENDIDO MEDICI N 2 M S 3 SUPERFICIE VOLUMEN FUNCIONES DE PIT GORAS UNIDADES BORRAR APAGADO PLANO DE MEDICI N MENOS Nou N Pantalla V ase la figura B Informaci n de mediciones incorrectas L ser ON Plano de medici n delante detr s Indicador del estado de las pilas Superficie Volumen Funciones de Pit goras Error de hardware Indicador principal Unidades con potencias 3 O Tracking m nimo 1 PrRFOONOAUNRWNE resultados previos 12 Tracking maximo Tres indicadores complementarios por ejemplo Selecci n de unidades Pulsar la tecla UNIDADES A 4 para seleccionar la unidad de inter s Unidades posibles Distancia Superficie Vo
18. le definir permanente mente el plano de medicin a partir del frente del instrumento Pulsando varias veces la tecla PLANO DE MEDICI N A 6 se restablecera el plano de medici n predeter minado del instrumento Medici n de distancias Al pulsar la tecla ENCENDIDO MEDICI N A 1 se enciende el l ser Apuntar al punto de inter s y pulsar nuevamente la tecla ENCENDIDO MEDICI N A 1 La distancia medida se visualiza inmediata mente en las unidades seleccionadas Tracking m nimo m ximo Esta funci n le permite al usuario medir la distancia m nima y m xima a partir de un punto fijo as como calcular el espacio existente v ase la figura E Se utiliza frecuentemente para medir distancias diago nales valores m ximos o distancias horizontales valor m nimo Pulsar y mantener pulsada la tecla ENCENDIDO MEDICI N A 1 hasta escuchar un pitido el cual indica que el instrumento se encuentra en modo de medici n continua Mover lentamente el l ser hacia adelante y hacia atr s y hacia arriba y hacia abajo alrededor del punto de inter s v ase la figura F G por ejemplo la esquina de una habitaci n Pulsar nuevamente la tecla ENCENDIDO MEDICI N A 1 para detener la medici n continua En la pantalla se muestran los valores de las distancias m nima y m xima as como el valor de la ltima medi ci n en el indicador principal Stanley TLM 200 1 0 0 e RAN Medir Funciones EE Adici n
19. lumen 0 000 m 0 000 m 0 000 m 0 00 m 0 00 m 0 00 m 0 00 ft 0 00 ft 0 00 ft 0 00 1 1 in 0 00 ft 0 00 ft 0 o Zh 0 00 ft 0 00 ft 0 0 in 0 00 ft 0 00 ft 0 1 16 in 0 00 ft 0 00 ft Encender Apasar el DISTO Encender Apagar Pulsar brevemente la tecla de ENCEN DIDO MEDICION A 1 El estado de la bateria se visualiza hasta que se pulsa la siguiente tecla Mantener pulsada la tecla BORRAR APAGADO A 5 Para optimizar la dura ci n de las pilas el instrumento se apaga autom ticamente transcurridos tres minutos de inactividad Manejo es Stanley TLM 200 1 0 0 e Tecla Borrar Al pulsar la tecla BORRAR APAGADO A 5 se elimina la ltima entrada o medici n En el curso de una funci n superficie volumen etc se pueden eliminar una a una las mediciones anteriores y medir de nuevo Iluminaci n La iluminaci n de la pantalla permanece activa durante 15 segundos despu s de la ltima pulsaci n de una tecla Plano de medici n La parte trasera del instrumento se considera el plano de medici n por defecto Es posible cambiar este ajuste al pulsar la tecla PLANO DE MEDICI N A 6 de tal forma que la siguiente medici n se tomar a partir del frente del instrumento Posterior a esta medici n el ajuste del plano de referencia autom ticamente vuelve a ser la parte trasera V ase la ilustraci n D Al pulsar durante m s tiempo la tecla PLANO DE MEDICI N A 6 es posib
20. t utilis e pour des mesures perpendiculaires la cible Voir figure 1 Presser la touche SURFACE VOLUME MESURE INDI RECTE A 3 trois fois L ic ne correspondante B 6 apparait La distance mesurer clignotera sur l cran Prendre les mesures n cessaires Le r sultat et les mesures simples s affichent Une vis e angle droit est n cessaire pour la deuxi me mesure utiliser la fonction Mesure minimum maximum conform ment aux explica tions Fonctions EDEN Stanley TLM 200 1 0 0 f Messages affich s Tous les messages comportent les textes InFo ou Caract ristiques techniques Port e utiliser un voyant partir de 70 m env 0 05 ma30m Pr cision de mesure jusqu 30 m typ 3 mm 1 8 max 5 mm 1 5 Error Les erreurs suivantes peuvent tre corrig es 2 o cart type InFo Cause Solution Plus petite unit 1 mm 1 16 a affich e 204 Erreur de calcul R p ter l op ration d i 252 Temp rature trop Laisser refroidir Base idee I haute l instrument Type laser 635 nm 1 mW 253 Temp rature trop R chauffer O de point laser 6 30 mm basse l instrument distance 10 30 m 255 zone de ae Utiliser la plaque de Arr t automatique au bout de 180 s rop faible dur e de mire mesure trop longue Ecran LCD 4 256 Signal d entr e trop Utiliser la plaque de Eclairage intense mir
21. the device is in a continuous measuring mode Then slowly sweep the laser back and forth respectively up and down over the desired target point see figure F G e g a corner in the room Press ON MEASURING key A 1 again and the continuous measurement will be stopped The current values for maximum and minimum distances are shown in the display as well as the last measured value in the main line Functions Addition Subtraction Take the first measurement addition is executed by pressing the PLUS key A 2 and subtraction by pressing the MINUS key A 7 then take the next measurement This process can be repeated as many times as is required The result is displayed in the main line whilst the last measurement taken is also Measuring displayed Pushing the CLEAR OFF key A 5 undoes the last step Areas and volumes can be added subtracted in exactly the same manner Area Press AREA VOLUME INDIRECT MEASUREMENT key A 3 The corresponding symbol B 5 appears in the display The first side to be measured flashes on the display Take the two measurements the result will be displayed in the main line Volume Press AREA VOLUME INDIRECT MEASUREMENT key A 3 twice The corresponding symbol B 5 appears in the display The first distance to be measured flashes on the display When 3 measure ments have been taken the result will be displayed in the main line Indirect Measuring Pythagoras
22. ur when measuring toward colourless liquids e g water or dust free glass styrofoam or similar semi permeable surfaces Aiming at high gloss surfaces deflects the laser beam and measurement errors can occur Against non reflective and dark surfaces the measuring time can be increased Care Do not immerse the unit in water Wipe off dirt with a damp soft cloth Do not use aggressive cleaning agents or solutions Treat the optical surfaces with the same care that you would apply to eyeglasses and cameras Warranty The Stanley TLM 200 comes with a one 1 year warranty from Stanley Works For more information on the warranty please go to www stanleyworks com In case of any questions concerning the warranty please contact the dealer who you purchased the instrument from All illustrations descriptions and technical specifica tions are subject to change without prior notice Appendix 6 TI Stanley TLM 200 1 0 0 gb Manuel d utilisation Version 1 0 Francais Nous vous f licitons pour l achat de ce Stanley TLM 200 AN KA annexe Veuillez lire attentivement les consignes de s curit et le mode d emploi avant la premi re mise en service du produit Remarque Les premi res et derni res pages du mode d emploi contiennent des repr sentations du produit Ces pages devraient tre d pli es pendant la lecture Les lettres et num ros entre se r f rent toujours aux illustrations Vous trouverez les consignes de

Download Pdf Manuals

image

Related Search

Related Contents

Adaptec DVPICS PLUS RETAIL KIT  Tripp Lite Protect It! 8-Outlet Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Fax/Modem/Coax Protection, RJ11  Informação de segurança (Parte do manual de instruções Chave de  - Manhattan  Bulletin n°19  UECE 2011 Manual de Redação Vicente Jr.  Lectures complémentaires 1ère  Abfrage / Programmierung  ー 縄ニっ~ニニ〝: 法  ECS 865-M7 (V1.1)  