Home
AlphaTRAK Lancing Device
Contents
1. AlphaTRAK Lancing Device LANCING DEVICE INSTRUCTIONS FOR USE For use with AlphaTRAK Blood Glucose Monitoring System from Abbott Animal Health Intended Use To obtain capillary blood samples for blood glucose testing This lancing device is a simple reliable way to acquire a drop of capillary blood for testing It includes a system to adjust the depth of puncture to accommodate multiple testing sites CAUTION To reduce the chance of infection e Never share a lancet or lancing device Always use a new Sterile lancet Lancets are for single use only Cocking Handle Depth Settings Dial Depth Indicator Window Release Button _ Clear Cap Contents 1 Lancing Device 1 Clear Cap 1 Instructions for Use Read all instructions for the AlohaTRAK Blood Glucose Monitoring System and the lancing device carefully before testing For additional instructions consult your veterinarian veterinary surgeon Lancing Device Instructions For Use To obtain a drop of blood 1 Gather supplies needed lancing device lancet 2 Wash hands with warm soapy water Dry thoroughly 3 Snap the cap of the lancing device off at an angle Insert a new lancet firmly into the white lancet holder cup Pushing the lancet into the cup may cock the device this is okay Note Do not share or re use lancets 7 Hold the lancet firmly in place with one hand use your other hand to twist off the rounded top EA Replace t
2. sur le site de pr l vement choisi Appuyer sur le bouton d clencheur pour obtenir une goutte de sang Le fait d appliquer une pression constante au site de pr l vement peut aider la formation d une goutte de sang Approcher le lecteur et la bandelette de dosage AlphaTRAK de la goutte de sang Toucher l g rement l chantillon de sang avec une seule extr mit de la bandelette de dosage S assurer que l chantillon entre en contact avec l extr mit mince de la bandelette de dosage au niveau de la zone noire l chantillon p n trera dans la bandelette de dosage par capillarit 14 Enlever le capuchon du dispositif autopiqueur en tirant a angle sur les deux extr mit s Afin d viter une piq re accidentelle avec l aiguille placer le capuchon de s curit de la lancette sur une surface dure Ins rer l extr mit de la lancette avec pr caution dans le capuchon de s curit Appuyer sur le bouton d clencheur pour avoir acc s l attache blanche qui retient la lancette Pincer l attache blanche qui retient la lancette jusqu ce que la lancette tombe ou tirer sur la lancette pour la retirer du porte lancette sate Les r glements relatifs la mise au rebut de produits m dicaux et d objets pointus peuvent varier il faut donc s assurer de conna tre les r glements qui s appliquent Jeter la lancette usag e de fa on appropri e dans un contenant r sistant aux perforations Re
3. lancette dans le r ceptacle peut armer l appareil ce qui est correct Remarque Ne pas partager ni r utiliser les lancettes 5 6 Tenir la lancette fermement avec une main utiliser l autre main pour casser l extr mit arrondie par torsion Replacer le capuchon et l enfoncer en place jusqu ce qu un d clic se fasse entendre Prendre garde de ne pas toucher l aiguille d couverte de la lancette Le dispositif autopiqueur permet quatre r glages diff rents Le niveau 1 est le moins profond le niveau 4 est le plus profond D placer la molette jusqu au r glage d sir affich dans l indicateur de profondeur Le capuchon transparent permet de mieux voir le site de pr l vement Une plus grande pression sur le site de pr l vement peut tre exerc e afin d augmenter la profondeur de p n tration Tirer sur le levier d armement fonc jusqu ce qu un d clic se fasse entendre Il est possible que le levier ait t arm l tape 4 ce qui est correct Il est maintenant possible de proc der a un dosage de la glyc mie Avant le pr l vement s assurer que le site de pr l vement est propre et sec et s installer avec l animal dans un endroit confortable et bien clair Le fait de r chauffer ou de masser le site de pr l vement augmentera la circulation sanguine cet endroit Maintenir fermement le dispositif autopiqueur ou le capuchon transparent
4. a hard surface Carefully stick the lancet tip into the safety cap 16 Push the release button to allow access to the white clip that holds the lancet Pinch the white clip that holds the lancet until the lancet falls out or pull the lancet straight out of the holder T The rules for disposing of medical products and sharp objects vary so be sure you know what is appropriate in your area Discard the used lancet properly in a puncture resistant container 18 Replace the cap to prevent loss of cap Use isopropyl alcohol available in the USA or soap and water to wipe the outside of the lancing device If you wish remove the cap wash it in warm water and rinse well Important Do not immerse the body of the lancing device in water or any other liquid For Technical Service and Customer Service call USA and Canada 888 299 7416 For Technical Enquires UK call 44 0 1628 644354 Veterinary medical device for use under the direction of a veterinary professional Distributed by Abbott Laboratories Ltd Abbott House Vanwall Business Park Maidenhead SL6 4XE United Kingdom Abbott Laboratories North Chicago IL 60064 USA c Abbott Product of USA ART26247 Rev A 11 11 2011 Abbott Laboratories C Dispositif autopiqueur AlphaTRAK MODE D EMPLOI DU DISPOSITIF AUTOPIQUEUR Doit tre utilis avec le syst me de surveillance de la glyc mie AlphaTRAK d Abbott Sant animale Utilisation pr vue Pour obte
5. he cap until it snaps or clicks into place Be careful not to touch the exposed needle on the lancet The lancing device offers four different settings Level 1 is the shallowest depth Level 4 is the deepest Move the dial to the desired setting as shown in the depth indicator window The clear cap allows for better observation of the testing site Greater pressure of the lancing device against the testing site can be used to increase the puncture depth Pull the dark cocking handle out until it clicks You may have already cocked the handle in Step 4 this is okay You are now ready to perform a blood glucose test Prior to testing make sure the testing site is clean and dry and select a comfortable and well lit location for you and your pet Warming and massaging the test site will encourage good blood flow Hold the lancing device firmly or the clear cap against the selected testing site Push the release button to obtain blood drop Applying continued pressure to the test site may help with the formation of a blood drop Bring the AlphaTRAK meter and test strip to the blood drop Gently touch only one side of the test strip to the blood sample Ensure the sample touches the thin side of the test strip in the black application area Capillary action will pull the sample into the test strip 14 Snap the cap of the lancing device off at an angle 15 To prevent an accidental needle stick place the lancet safety cap on
6. mettre le capuchon en place pour ne pas le perdre Utiliser de l alcool isopropylique vendu aux Etats Unis ou de l eau et du savon pour nettoyer l ext rieur du dispositif autopiqueur S il y a lieu retirer le capuchon le laver l eau ti de et bien le rincer Important Ne pas immerger le dispositif autopiqueur dans l eau ni dans aucun autre liquide Pour joindre le Service technique ou le Service la client le Canada et tats Unis composer le 888 299 7416 Pour joindre les Renseignements techniques Royaume Uni composer le 44 0 1628 644354 Dispositif m dical v t rinaire qui doit tre utilis sous la supervision d un v t rinaire Distribu par Abbott Laboratories Ltd Abbott House Vanwall Business Park Maidenhead SL6 4XE Royaume Uni Abbott Laboratories North Chicago IL 60064 tats Unis ce Abbott Produit des tats Unis 2011 Abbott Laboratories
7. nir un chantillon de sang capillaire pour le dosage de la glyc mie Le dispositif autopiqueur est une fa on simple et fable d obtenir une goutte de sang capillaire pour mesurer la glyc mie Il comprend un syst me permettant d ajuster la profondeur de la piq re afin de faire des pr l vements des endroits diff rents MISE EN GARDE Pour r duire les risques d infection Ne jamais partager une lancette ou un dispositif autopiqueur Toujours utiliser une nouvelle lancette st rile Les lancettes sont usage unique Levier d armement Molette de r glage de la profondeur Indicateur de profondeur Bouton d clencheur fal Capuchon transparent Contenu 1 dispositif autopiqueur 1 capuchon transparent 1 mode d emploi Lire toutes les instructions concernant le syst me de surveillance de la glyc mie AlphaTRAK et le dispositif autopiqueur avant de les utiliser Consulter un v t rinaire chirurgien v t rinaire pour des instructions suppl mentaires Mode d emploi du dispositif autopiqueur Pour obtenir une goutte de sang Rassembler tout le mat riel n cessaire dispositif autopiqueur lancette Se laver les mains avec de l eau ti de savonneuse et les ass cher compl tement Enlever le capuchon du dispositif autopiqueur en tirant angle sur les deux extr mit s Ins rer fermement une nouvelle lancette dans le r ceptacle du porte lancette blanc Le fait de pousser la
Download Pdf Manuals
Related Search
Related Contents
UEIPAC Software Development Kit User Manual 1.2 User Manual - Projector Central One For ALL URC-7040 User's Manual User Manual - Projector Central RECIPROCATORE VERTICALE USER`S gUidE Manual de instalação e operação Copyright © All rights reserved.
Failed to retrieve file