Home
MC(L・H)
Contents
1. 32 When the hose is not connected properly the replacement interval may shorter than listed in guidelines For details please contact Matsui Mfg 0 3m R1 4 2 0 5m R1 4 Options Mold Temperature Controller Options 5 MC L H A MCLX MCHX MCAX Cod Description X Without X type TBL ELTB Earth Leakage Breaker with TBL Replaced with basic model s open circuit voltage breaker Prevents earth leakage accidents 70db MCJ AA Alarm Buzzer An electronic buzzer to alarm with 70db sound Standard specs forMCJ AA GS NO External Control Startup Shutdown NO input For synchronous operation remote control of molding machine GA NO
2. Type A AX Subtanks Please install in place with much capacity like roll jacket 3 SE T5 Please install in place with much capacity like roll jacket ONE T10 Please install in place with much capacity like roll jacket T15 Please install in place with much capacity like roll jacket 400 5Barreltherm 400 820kg i 400 5Barreltherm 400 4kg QMCLX 200 X J 1 AtOK At 1 3 10L 15L MCA 25 55 88 MCAX 20 50 Notes MCLX 200 X J X x xX Xto be filled in with option codes For non coded options pro
3. Display temperature of precision up to 0 7C Memory function that saves 2 different temperature for easy alternation Reliable SSR Heater control circuit uses SSR non contact relay Shunt coil breaker shuts down power automatically upon excessive heating ww Application L A set A set Hose L Type L B set se7 Hose L Type Teflon Hose Set H Hose H Type Medium Water gy Water S rs0 Max operating temperature 60C lt 60C 95C lt 95 120C 120C 200C lt 200C Max Pressure 0 49MPa 0 98MPa Material Pupoer zz Lengthx Qty 2 Quantity of 2 direction set Rubber Rubber 12 6m 26m 3mx4 0 5mx2 3mx4 0 3mx2 hose joint hose clamps 3mx4 0 5mx2 3mx4 0 5mx2 3mx4 0 3mx2 Replace Interval 2000h
4. Alarm Output NO output Reduces defects by early detection of troubles WT ON OFF Dayly Timer Turns on off on a weekly basis tOK 1 tOK N0 tOK Signal Output 7 NO output Control signal to check returning temperature for stable molding OK COK NO Control OK Signal Output NO output Control signal to check feeding temperature for stable molding PL Alarm indication lamp Signals the alarm with a rotating lamp HD 1 IWire Breakage Alarm Heater Detects a heater wire breakage to prevent molding defects KS 5m K 3 2xX 150L 93 2X 1 4B External Sensor Mold 2 Cable 5m Sensor 3 2X7507 w ring joint 3 2X1 4B Control using mold temperature At K
5. Thermostat for Heater Supply and cooling Safety valve solenoid valve NBN Vg overheat prevention Bypass valve NT Vb Bypass valve Medium feed valve Medium feed valve Sensor Drain port 4 Drain port S SS cD C 9 S nw 2AR Strainer Strainer gauge Relief valve Wat 7 at r supply por Water supply port Pressure gauge MC 25 55 88 L 1 pe Direct cooling H 7 pe ndirect Cooling 85C Direct Cooling below 85 c Cooling solenoid valve Drain port p a Cooling solenoid valve Water level gauge Electric rod Water supply port Thermostat for overheat prevention Water supply Cooling solenoid valve 5Bypass valve Medium feed Solenoid valve for water drain Bypass valve Medium feed Control sk Medium return Medium return valve OR 2 Medi
6. MCL MCLX B0C 8 pH 6 8 50 200us cm 18C L LX 50C H HX 100C NOTE1 7 Operating temperature range may vary according to supply water temperature 2 Pump head depends on specific gravity and viscosity of medium used 9 Models operate at 50Hz and 60Hz cycles 7 cannot be used in an area of different cycle 4 For product improvement specifications in this catalog may be changed without prior notice 5 Mechanical seal may produce slight leakage of water 6 Land H type controllers with floatless switch cannot be used with distilled water pure water and high purity water For details please contact to Matsui sales office 7 In the case that the drainage is being exposed maximum temperature of MCL MCLX Series is 97C due to pump cavitation IWater quality Water quality standard level of supply water on the Japan Refrigeration and Air Conditionin
7. 7 segments Indication Ce i Reverse phase Insufficient water Overwork of pump ME Overheating Under heating Sensor failure N AD cD SS G S 1 CO M TSUI Ensures higher accuracy in temperature control and high level of safety during operation Reminders for periodical maintenance and other maintenance items can be easily set MR 980 Operating Status Temp Display Setting Digital Display Setting PID Temp Controller Heating amp Cooling PID Control a Alarm K PT 1000 MONITOR Input PV SV SF DWN Up BT MONITOR SV1 gy2 Eb gt 4 2 BE mi Onn eo SV1 V2 AA ER 0 99 59 ON OFF M TSUI os 0 99hrs 59min Turns ON after setting LCD LCD message display Operation Status Alarm Periodical Maintenance 1 High Precision 0 1C
8. External Sensor Medium return 2 Sensor K Checks returning temperature for stable molding SPI MR 980 SPI980 SPI Communication SPI MR 980 Machine and quality control from molding machine through standard protocol CV SPI Ethernet Converter An option for 5 communication 38380 400 415V 50Hz 380 400 415V Compatible with 50Hz 30V 60Hz 00V 360V 60Hz 360w6oHz only A Motor Voltage Options 230V 60Hz Standard model equipped with 200V 38380 400 460 480V 60Hz 380 400 460 480V Compatible with 60Hz F Mc Jet Series s motor F type insulation offers a variety of voltage options operation voltage PS 100V Z Custom color Specify JPMA color or advise with color sample attached 3 8B 4 way M4 LX 200 HX 200 AX 50 AX 140 LX 200 HX 200 AX 50 AX 140 07 LX HX AX 6 way M6 Manifold Options Standard specs for 3 8B LX HX AX Only 8 way M8 A AX T3
9. Pump gauge a R Caster MC L H 88 Water supply port mm 664 unit mm 5 Breaker Pressure regulation valve Ball valve MC L H 88 HN10x3 8B nHN10x3 8B hose nipple strainer Water drain port HN10x3 8B HN14X3 8B hose nipple Medium feed port Rc PT 38 8Bx65 nrc PT 3 8Bx6ball valve Medium return port Rc PT 3 BBX6 krc PT 3 88x6ball valve A pj cap only MCA 3 8B A 6 oer flow po7 only MCA HN10xX1 4B 7 x 748 socket MC 88 mm unit mm 690 A type Water drain port Drain CT pe Flow Chart MCL 5 J MCH 5 J ll id I NE Water drain solenoid valve Float switch Medium return valve A YF Medium return valve s EU a Thermostat for oerheat prevention Pump
10. 6 9 10 8 geake A 20 15 30 15 30 40 W mm 180 230 280 Outer Dimension D mm 682 664 737 D1 mm 472 523 580 D2 mm g10 141 157 H mm 480 580 690 Product weight kg 45 45 55 70 50 200ms cm pH 6 8 Water guality Add anti rust agent at about the water guality standard of make up water as per standard of Japan Refrigeration and Air conditioning Industry Association m PH6 8 water not containing large amounts of calcium silica chlorine and iron 1 1 3 50Hz 60Hz 4 5 6 L H 7
11. Water supply temperature Water supply temperature Water supply temperature Water supply temperature Water supply temperature Water supply temperature Cooling capacitr 1kW 860kcal h KW 5 8 8 1 5 8 8 1 11 6 8 1 Heater kW 2 3 9 5 9 5 8 Heater pox capacity L 0 85 1 5 9 J 4 4 g 0 2 6 5 8 2 6 50Hz L min 17L min 10m 28 10m 50 10m 28 10m 50 10m 70 10m 60Hz L min 21L min 10m 30 10m 55 10m 30 10m 55 10m 90 10m Pump Motor 50Hz 60Hz kW 0 3 0 6 0 3 0 6 Flow rate amp Lift Refer to the pump performance curve RE oA Direct cooling Direct cooling Indirect cooling Direct cooling Direct cooling Indirect cooling Direct cooling Cooling water Fow rate L min 10 4 7 9 10 10 presswe MPa 0 2 0 4 0 950 8 aNG USS 0 2 0 5 Waterleveldetector Foat swich Foatless swich mput K Kype Thermocoupke K Control Panel MR 980 QO MR 90X 7 gm Power spp V AC200 200 220V 50 60Hz 3 3Phase Power consumption kVA 4 7 4 5 6 9 4 5
12. 2000h 4000h 6500h Hose Connection Me MR Protection SUS SUS blade w guard spring to prevent hose cracking MC Option Matrix MC 5L J MC 5H J MCL 25J MCL 55J x2 MCL 88J OX O 0ptions Not available For delivery terms of hoses not listed MCH 5J in this catalogue please contact MCH 55J C X2 Matsui sales office MCH 88J MCA 25J Ox3 MCA 55J MCA 88J MCAX 0 Please select when adding manifold as for following MCAX 50 MCLX 200 MCLX 350 MCLX 450 MCHX 200 DEC 0 MCHX 350 MCHX 450 MCAX 140 MCAX 50 MCAX 400 te Le io I Le 200 Nipple Options Hose connection diameter Straight type Code No G
13. MC L H MC LH O HE MCLH 59 99 88 kN t Clamp force for injection molding machine Operating temperature range Model Operating temperature range Model NC 25 55 88 plas aid 500 750 1500 1250 2500 50 75 150 125 250 a 10 95C MCL 25 X J MCL 55 X J US MCL 25 J MCL 55 J 10 120C MCHB MCH 25 X J MCH 55 X J 50Hz 60Hz 0 30 40 Fow rate 50 60 70 L min 80 90 100 2500 4500 250 450 MCL 88 X J MCL 88 J MCH 88 X J MCH 25 J MCH 55 J MCH 88 J MC 55 X J 4 GA HH LE MC 88 X J MC 88 J Standard Specifications Model Medium 5 X J MCL 25 X MOL55XJ MCHe5XJ MCL25J MCL55J MCH2SJ MCH 55J IMCH 55 MCH55XJ PDD J MCL 88 X J ciean water soft water MCL 88 J MCH 88 J MCH 88 MCH 88 X J PDD J Operational temperature range 10 lt 90 10 180 0 10 120 60 120 10 95 10 120 60 120
14. g Industry Association PH The water which pH 6 8 conductivity 50 200 p s cm calcium silica chlorine and iron aren t much contained in The cooling capacity has cooling Water temperature in 18 C In the medium temperature that L LX type is 50C H HX type 100C Cooling capacity is subject to cooling water temperature pressure medium temperature and circulation flow Quter Dimension 5 MC L H 25 55 N 1 Water supply port 3 BBX1 385X 1hose nipple strainer N Water drain port 3 8BB lt 1 368gx 1hose nipple N 3 Medium eg port Rc PT 3 8BX2 rc PT 3 8Bx2ball we RC PT 3 8BX4 Rc PT 3 8BX4ball valve N 4 Medium return port Rc PT 3 8BX2 Rec PT 3 8BX2ball valve RC PT 3 8BX4 Rc PT 3 8BX4ball valve N 5 1 lt A gt Drap port Only MCA 3 8B 3 8B ball valve N 5 2 L H gt Drain port LH type 1 4B 74g plug N 6 A gt Oilover flow po7707 04 1 4BX1 1 4BX1 socket MC Control panel Egg
15. o 2861 EMIEYES Straight ER se Options R1 4 A B 2862 3 8Bx1 4B BSBM straignt G3 8 R1 4 4ccessoy 2863 3 8Bx3 8B BSBM swagr G3 8 R3 8 4ccessoy 1 Please replace the hose periodically according to the replacement guideline Teflon hoses is recommended for longer operation The replacement guideline in this catalog is based on 24 hrs operation L A 24 2 To prevent accidents the hose should be connected properly L Length LL 2 Please read the hose operation manual carefully 3m R3 8 3
16. um return valve relief valve Heater stop valve Strainer gt Water supply port reducing valve XX Water drain solenoid valve MM for overheat prevention 0 switch Bypass valve my water drain port heater box medium supply valve QI medium supply port Control sensor amp _ pressure gauge a Safety valve Pump medium retuyrn valve medium return port MR 90X Temp Display Setting Digital Display Setting PID Temp Controller Heating amp Cooling PID Control 005 K PT1000 SV1 SV Memory SV1 SV2 0 99 59 ON Timer 0 99hrs 59min Turns ON after setting
17. vide reguired specifications 1 AtOK Signal Option comes with External Sensor Medium Option 2 Choose either External Sensor Mold or External Sensor Medium Option 3 Two types of tank 10L 15L are not avalible for these models MCA 25 55 88 MCAX 20 50
Download Pdf Manuals