BGS-HL シリーズ

image

Contents

1. 1 2 3 4 2s
2. 600 8815 91 TEL 075 325 2920 FAX 075 325 2921 http www optex fa jp Connection diagram FN Specifications I Setup Ss High resolution BGS sensor FASTUS Part number legend BGS HL__ 1 B G S H L S H E NPN type While it s Setup mode or Extension mode you can change the mode to RUN mode e ri es Ll Laser Class none Class 1 by clicking TEACH RUN button 2 Class 2 While it s Extension mode the LED MANUAL is lit Changing mode BGS HLOST L BGS HL25T LIL Instruction manual Thank you for purchasing BGS HL series We hope you are satisfied with its performance o DC 12 24V Connect type none Cable Control Output ec M8 Connector Working distance cm RUN mode Please read this manual carefully and keep it for future reference Specifications Part Cable type BGS HLO5T BGS HL25T2 Setup mode number Connectortype BGS HLO5TC BGS HL25TC2 Display 0 00 30 00 Display 0 0 200 0 Light source ae ee IEC JIS CLASS 1 CLASS 2 Extensi
3. 6 as BGS HL R 10mm 30mm M3 X 2 0 5N m HRVEINAIL OUT ON L__ MANUAL LASER t Kcaae Ds BGS HL YU ADE FORE E FHOBBAACOW CHALE t Keene BGS HL TEACH RUN MANUAL LED VOuT a A MANUAL Hoare pe DC A ser MM E f LASER MANUAL HARE ALASER A MANUAL OREHE
4. FGS TEACH RUN 1Pt J mg ON M SET lt yos HZA E E 2 x 2 SET E E 3 SET po P j El EREE Enn ms E 5 Eg e i oF OY E E 6 ZONE
5. Ds JIS C6802 IEC 1 2 ll FD A Food and Drug Administration CDRH Center for Devicesand Radiological Health Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to laser notice No 50 dated June 24 2007 OPTEX FA CO LTD 91 Awata cho Chudoji Shimogyo ku Kyoto 600 8815 JAPAN Place of manufacture OFROM CO LTD Manufactured in EN IEC 60825 1 2007 Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to laser notice No 50 dated June 24 2007 EN IEC 60825 1 2007 Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to laser notice No 50 dated June 24 2007 tinOts Ds
6. ON 2 ON 2 TEACH RUN 1Pt TEACH RUN 2Pt 2Pt es f gt gt ES 2 1 ON p Y lt ZONE ZONE ON
7. E EE 2 BREE ceems BGS HLO5 0 15 BGS HL25 1 0 E EO lt RR ten ceva gt PAP PNP reset Ds e O YIRE RUN SIG 1 oc RUN e EE Gout soc WE vexenss Dy BGS HL B Imin 2 z z x uy N 45 4 2m Cable MoOA 725 BGS HL A
8. SET TEACH RUN VOUT OUT TEPI SET NT can 00 00 2 a UI ALASER A MANUAL a SET m LASER A MANUAL TEACH RUN 2 OUT Scu0 EN mm Fr ae Ax AE lt 2 ALASER A MANUAL VOUT ALASER A MANUAL 2 ALASER A MANUAL VOUT ALASER A MANUAL BEL 2 TEACH RUN 2 SET
9. 0 BGS HL25 E 4 AUG SET 1 x 8 64 512 5 EhrE x 400 E 200 100 O 5En5 D GRE t erene 6 6 a 2 821 SAAP Pid 5 500us 2kHZ DOO 1000us 1kHz x E Emma 2000s 50012 H000 4000us 250Hz GE aro X1 BGS HL05 500us BGS HL25 1000 us 2 AUTO
10. BGS HL M3 X 25 2 NPN PNP E NPN o 12 24V E PNP M8 a PAS dt Ds E F nama oO 31 0 2 pu ees x ea N key St ee f LE E OL 4 55 4 2m Cable 0 23mm AWG24 M8 Ya C J CRED EVE Kes teste e eye eyes 12 5 REPL BGS HL T 1 2 2 C MB cm BGS HLO5T C BGS HL25T C 2 20 50mm 50 250mm 0 00 30 00 0 0 200 0 0 01mm 001 0 1mm 0 1
11. REE seesi ope BGS HLO5 03 00 BGS HL25 020 0 E E Loon sg ON gt a PE 2s ssememensrnscon x OFF EED ON ON ON Fr M Menu Ex on k E E lt REGS omeo z EEA oonan c 3 SET ee ass 0 OFF e X 0 2 2
12. 008mm 08mm 655nm s y bg 3900W _ mW wi IIEC JIS CLASS 1 CLASS2 1 5ms 1 5 7ms 1 5ms 3 14ms 0 22 49 0 15 0 149 9 1 0 1 2 7 4 Hr LED NPN PNP 100mA max DC24V 1 8V ON ON 1ms 2m DC12 24V p p 10 40mA IP67 10 50 C 35 85 RH OKE REZE
13. bASE Base Set threshold to lowest level x Set threshold level to detect rising part and falling part of light strength wave You can change the threshold level especially when the sensor receives external light as noise so to get stable detection Basically you don t have to change the threshold 6 Maximum sensitivity Auto Adjust sensitivity automatically x 1 Minimum sensitivity 500us 2kHz x 1000us 1kHz x 2000us 500Hz 4000us 250Hz AUTO Default 500 us BGS HLOS5 1000 us BGS HL25 Auto The sensor optimize sampling period automatically EEEE Set the value Default BGS HL05 0 15 BGS HL25 1 0 Po Set input output as NPN x Set input output as PNP This parameter won t be changed by Reset m 1 Display setting Loop Miscellaneous function m Key lock function Activate Key lock While it s RUN mode press 4 Then Loc will be shown While Key lock is activated any access except Release Key at a time for 1 second lock will be neglected Release Key lock While Key lock is activated it will be released by pressing at atime for 3 seconds Then i will be shown After this process every access will be accepted Dimensions with bracket E Cable type with standard bracket BGS HL B 42 5Emitter axis 38 2 8 7 4 5 4core 2m Cabl
14. 20 60 C 35 85 RH 5 000 Ix 10 55Hz 1 5mm X Y Z 2 500m s 50G XY Z 3 PPSU PET PVC 90g 309 M8 IRD FS 23 DC24V 500us 512 BGS HLO05T C 1 35mm BGS HL25T C 2 150mm X1 ON 0 BGS HL05 7 50 37 50 BGS HL25 50 0 250 0 FFF FFFF 9999 2 1000us 3 0 02 BGS HLO5 0 2 BGS HL25 4 CLASSI 5 1 e 13 5
15. Teach position threshhold When the distance between the object and Teach position gets big ger than the distance set at ZONE ON distance the output will be F ON Setup mode E 1 Teaching mode Ech m2 Extension mode m 3 External input SET E m4 Delay time m 5 Output delay EE E You can get to Setup mode by clicking SET button from RUN mode means default value 1 point teaching ZONE teaching 2 point teaching To Extension mode OFF Disable external input Laser OFF Kill laser power when input is ON Teaching Set current value as threshold Sample hold Keep the level when input is ON One shot hold Hold the value as input turns ON 0000 Set the value unit ms OFF Disable output delay Off delay On delay One shot How each mode works m 6 ZONE distance E i ai i L p EEEE Set the value Default BGS HLO5 03 00 BGS HL25 020 0 m 7 Light ON Dark ON selection toon E Light ON When the distance is closer than Threshold the output will be ON ZONE Teach mode When the distance is outside of ZONE distance the output will be ON While it s out of range the output will be OFF Dark ON When the distance is farther than Threshold the output will be ON ZONE T
16. English manual is on flip side FASTUS BGS HL BGS HLO5TLI BGS HL25T LIL 0566461 ae A
17. Front lens PPSU Display PET Weight Cable type Approx 90g including cable You can change threshold level directly by and buttons after clicking TEACH Do not wire with the high voltage cable or the power lines Failure to do this will cause Connector type Approx 30g RUN button from RUN mode malfunction by induction or damage Di mensions I The specifications are based on the condition unless otherwise designated Ambient temperature 23 C Sup By pressing TEACH RUN button for 2 seconds or more it gets to Teaching mode It Do not use the sensor in a transient state at power on Approx 2sec Warm up period Do not use the product in water ply voltage 24VDC Sampling period 500us Averaging 512 Measuring distance Center of the range Testing te 3 ea pees you 1 ve in Setup mode ae E Cable type mm object White ceramic ease refer Teaching mode and Setup mode on next page Operate within the rated range Imml 1 When Shift in Extension mode is ON the display shows 0000 at the Teaching point Wipe off dirt on the emitting receiving parts to maintain correct detection Also avoid lt The range that the display can show is as follows direct impact on the product ki BGS HL05 7 50 37 50 BGS HL25 50 0 250 5 Click When the distance exceeds this range in Sensing range the display shows FFFF Although the sensor VOUT works wh
18. H RUN button Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure gt O O Q 2 VOUT SET Timer function OFF On delay Off delay One shot MG EE fet canoe Mie cone A Warning Safety Precautions Supply voltage 12 24VDC including 10 ripple TEIT ALASER A MANUAL ALASER A MANUAL 40mA max 24VDC excluding the current of Control Output It is dangerous to wire or attach remove the connector while the power is on Make sure E g p to turn off the power before operation E Pins configuration M8 connector type Protection circuit Reverse connection protection Over current protection i Protection categor IP67 Installing in the following places may result in malfunction emeralds White Black ow m 85 RH without freasi 1 Adustpor steamy plac Operating Temp Humid 10 50 C 35 85 without freasing or condensation 2 A place generating corrosive gas Storage Temp Humid 20 60 C 35 85 RH 3 A place directly receiving scattering water or oil Ambient illuminance Incandescent lamp 3 000 Ix max i 4 A place suffered from heavy vibration or impact A Blue Vibration resistence 10 55Hz Double amplitude 1 5mm X Y Z for 2 hours Teach function 2 The product is not designed for outdoor use Shock resistence 500m s approx 50G X Y Z 3 times each Case Aluminum
19. TEACH RUN BRL 2 TEACH RUN 2 Po BGS HL 3 ON OFF ON TEACH RUN II J D Ea 1
20. e E Connector type with standard bracket BGS HL A 12 5Emitter axis M8 4pin Connector Attention Not to be Used for Personnel Protection Never use these products as sensing devices for personnel protection Doing so could lead to serious injury or death These sensors do not include the self checking redundant circuitry necessary to allow their use in personnel safety applications A sensor failure or malfunction can cause either an ener gized or de energized sensor output condition Please consult our distributors about safety products which meet OSHA ANSI and IEC standards for personnel protection Specifications and equipment are subject to change without any obligations on the part of manufacture For more information questions and comments regarding products please contact us below Manufactured and sold by OPTEX FA CO LTD 600 8815 Kyoto Shimogyo Awata Chudoji 91 Japan TEL 81 0 75 325 2920 FAX 81 0 75 325 2921 Website http www optex fa com
21. each mode When the distance is inside of ZONE distance the output will be ON While it s out of range the output will be ON m 1 Teaching mode Loop Extension mode M You can get to Extension mode from 2 Extension mode in Setup mode means default value m 1 Display setting DEA E m 2 Reset Initializing ca z E 3 Shift function lt SET A E Activate the display Disable the display while Key lock Initializing will be done when the mode gets to RUN mode Initialize the parameters to default setting Do nothing Activate Set teach position as 0000 Not use x Set the display 0000 at the Teach position threshold when Teaching is done When it s 2 point Teaching set the display 0000 at near side position of 2 positions of Teaching Example of 1 point Teaching BGS HL25 Before Teaching After Teaching m4 Averaging SET D m 5 Treshold E e S m 6 Sensitivity Ez C m 7 Sampling period E m 8 Hysteresis c m 9 NPN PNP selection SET E Auto nb l ma 000 2000 DOD Gea lt _ position lt T m EA Sensing range P400 Set threshold to upper level P200 Set threshold to middle level P100 Set threshold to lower level i Once x BY 64 times Se 512 times
22. ile the distance is in Sensing range The display shows 9999 when the distance is out of range f Change X 2 Defined by light strength within 1 e 13 59 of spot center There may be leak light at outside of the P r threshold specified spot size The sensor may be affected when there is a highly reflective object at that leak light SET level directly 3120 2 area i Precautions for using laser M yet za 3 Sampling period 100048 1 E OUT Regulations in the USA 5 DE Display Press 2 seconds mes When exporting laser devices to the USA the USA laser control FDA z LA or more Let Teach current Food and Drug Administration is applied This product has been already N ea ser E _ G0 S position reported to CDRH Center for Devices and Radiological Health For Qi i pes details contact our customer service pe Functions of com ponents A LASER A MANUAL Control panel When it is 2pt teaching mode Cable minimum bending radius 10mm OUT Don t bend the cable of the outlet part up to 30mm from the case o Displays 2pt 0000L and current i 4 5 4core 2m Cable SET Lr P position ALASER A MANUAL alternately RUN mode Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to laser notice No 50 dated June 24 2007 E M8 connector type OPTEX FA CO LTD 91 Awata cho Chudoji Sh
23. imogyo ku Kyoto 600 8815 JAPAN Holes for installation EN IEC 60825 1 2007 EN IEC 60825 1 2007 Place of manufacture OFROM CO LTD Complies with 21 CFR Complies with 21 CFR IP M3 2 0 Gap ap as P 1040 10 and 1040 11 OO anc Ns Tightening torque must be l 6 0 except for deviations except for deviations 0 5N m Max Gy P pursuant to laser notice pursuant to laser notice f i No 50 dated June 24 2007 ALASER A MANUAL No 50 dated June 24 2007 er Lens Emitter Receiver Control panel Bundled goods in the box _ Please confirm following goods bundled in the box OUT ON when output is ON e 6 Display BGS HL e This instruction manual Screws ES M3 X 15 2 i H T 44 4 0 2 MANUAL LL MANUAL ON when Extension mode LASER ON when laser is emitted a Y A 4 EJ Bracket M8 4pin Connector Teaching mode BGS HL series has 3 Teaching mode Please choose a Teaching mode at Teach mode Eg in Setup mode before Teaching Output polarity can be reversed by Light ON Dark ON Following output shows its ON OFF status as Light ON 1 point Teaching Teaching is done at a position on the object to detect When the distance is closer than that position the output will be ON Press the TEACH RUN button unti
24. l the display shows 1pt Teaching is completed after releasing button Teach position threshhold When the distance is closer than the ON Teach position in Sensing range the OFF si 8 b output will be ON i hYSE Sensing range 2 point Teaching Teaching is done at two different positions on the object to detect Teach position will be set at center of these two positions When the distance is closer than the Teach position the output will be ON When the distance between these two positions is too close the display will show that means error Then please try again Click the TEACH RUN button without object to detect Then the display shows 2pt that means Teaching is completed 5 Press the TEACH RUN button until the display shows 1pt Then the display shows 2pt and the distance related number alternately ome O om Teach Teach position 1 position 2 When the distance is closer than the ee 3 Teach position in Sensing range the output will be ON wf OFF l ZONE Teaching Teaching is done without object to detect Teach position will be set at this position When the distance between the object and Teach position gets bigger than the distance set at ZONE distance in Setup mode the output will be ON Press the TEACH RUN button until the display shows 1pt Teaching is completed after releasing button J D EA
25. on mode class 1 sms max 1 5 7mgdefaut Scien Indicator Laser indicator Green Output indicator Orange Mode indicator Red Control Output NPN PNP selectable Changing Adjusting e 100mA max DC24V Residual voltage 1 8 V max parameter ea parameter assay External Input Laser OFF Teaching Sample Hold One shot hold que 5 O O Q External Input Indicates a possible hazard that may result in death serious injury WARNINGS or serious property damage if the product is used without observing the stated instructions F Ws A MANUAL J A Warning Mandatory Requirements E PNP type The light source of this product applies the visible light semiconductor laser Do not allow the laser beam to enter an eye either directly or reflected from reflective object If the laser beam enters an eye it may cause blindness Brown V 12 24V Black Control Output Gray External Input A LASER A MANUAL This product is not an explosion proof construction Do not use the product under flam mable explosive gas or liquid environment Do not disassemble or modify the product since it is not designed to automatically stop the laser emission when open Disassembling or modifying at customer s end it may cause personal injury fire or electric shock You can choose and adjust the parameters by clicking and buttons The mode will be changed to RUN mode by clicking TEAC