3. 10 m DMP DMM DMB 2 3 4 Zz 1 V 1 0 O 3 10 0 4 1 V 1 Moles 3 2 2 1 3 2
4. FFT 100 XS O 5kgf cm A M5 H M5 8 kgo HLE a CREU OPEN o
5. BR ermal PEQ Res tk Bj 4 4 DMP 100 FDT 100 0 OU gt gt IN mi Ou gt XIE eo lt DMB 100 DMM 1 00 E 2
6. 2 1 3 1 4 O eeomemareonsun 550 3 3 5 a 5 a A 5z Z 6 O
7. 5276 1 T394 TELO266 28 6072 t FAXO266 28 7379 4088 399 45 TELO265 76 251 1 FAX0265 76 2851 p Fi be r D ry Users Manual PNEUMAT eae MiThank you very much for purchasing our FIBER DRY FIBER DRY is a device designed specifically to eliminate the moisture contained in pressurized air ABOUT THIS OPERATION MANUAL This manual provides the information needed for proper use of FIBER DRY Please read it through before using FIBER DRY l Appearance amp Name of Each Part of Fiber ory Purging Flow Adjusting f Dial Purging Flow Installing Bracket Installing Bracket Adjusting Dial ka IN OUT gt gt re a gt O II gt j Drain Outlet 1 4 4 Purging Air Outlet Purging Air Outlet DMP 100 FDT 100 Purging Flow Adjusting Installing Bracket f Dial os 0 IN OUT Purging Flow gt al 5 gt Adjusting Dial Purging Air Outlet gt IN OUT gt gt Installing Bracket Purging Air eee DMB 100 DMM 100 2 Specification Fluid admitted Air Service pressure range O 9kgf cm O 150 psi Proof pressure 13 5kgt cm O 1 92psi O 40T 32 104 F Let the air flow into the l
8. 0 9kgf cm 0 150 psi 13 5kgf cm O 1 S2psi 0 40C KL YEARS 11cc FDT 7kgf cm 99psi 60C 20C 125NI min 4 40 SCFM 5NI min 2096 100NI min 3 52 SCFM 20C X ot Se ca BL d ooi ea e ee l j OR A gt 1 1 2 FDT 1 5 um
9. ine of Fiber Dry while the valve V 1 is closed At this time do not put the pressure of more than the specification on 2 Set required purging flow with turning purging flow adjusting dial Do not set purging flow adjusting dial to O which means purging flow is O 3 After adjusting the purging flow close the lock nut completely and keep the air run for 10 20 minutes for the initial drying 4 Operating Method Service temp range No freezing Drain capacity 11cc only for FDT Dehumidifying Performance Example Supplying pressure 7kgf cm 99psi Gauged pressure Supplying air temp 20T 6 8 F Supplying air vapor Saterated at 20C 68 F Supplying air flow rate 125Ni min 4 40 SCFM Purging air flow rate 5NI min 20 of supplying air flow rate Produced air flow rate Dry air flow rate 1OONI min 3 52 SCFM Dry air dew point 0C or below 13 F Under atmosheric pressure However the above figures are the measuring examples and the dry air dew point changes depending on the different above conditions 3 Piping x Fiber dry Dry air Malning L a om Purging line Purging flow adjusting 1 When supplied air contains dirt water or oil Transpiration in atmosphere throttle valve Equipped with fiber dry the result can be performance deterioration or shorter
10. mes to the center QPut lock button up then it is locked In replacing element apply the grease mineral oil to O ring oh Ts 3 Criterion of Discharging Drain LUEI p Case guard Discharge the drain before it reaches the highest part of the peephole of the case guard FULL UJ 1 Avoid operating it in the atmosphere of the organic solvent thinner etc or the chemicals since case is made of polycarbonate In washing use the neutral detergent Install case guard Surely Operating without it causes the damage of case Model amp Price of Replacing Element Model FFE 15 List plice 350 PC HIR0001 00 NIHON PISCO CO Ltd INTERNATIONAL MARKETING DEPT 4088 MINAMIMINOWA KAMIINA NAGANO PREF 399 45 JAPAN TEL 0265 76 7751 FAX 0265 76 7789 HEAD OFFICE AND PLANT 5276 1 OSACHI OKAYA CITY NAGANO PREF 394 JAPAN TEL 0266 28 6072 FAX 0266 28 7349 PISCO HANBAI CO Ltd HEAD OFFICE 4088 MINAMIMINOWA KAMIINA NAGAN PREF 399 45 JAPAN TEL 0265 76 2511 FAX 0265 76 2851 12
11. oid operating it where it is exposed to the direct sunshine rain water 7 Caution Never disassemble it Bs 8 Handling of Filter FFT 100 L 1 Handling of Drain Cock FFT 100 FFT 100 A M5 Female Thread Drain When the inside pressure of case is less than 0 5kgf cm the valve is pushed up the drain is discharged With the M5 female threading the 10 fitting can be installed Drain Button Push 2 Replacement of Element 66 9 Screwdriver S Case Case Guard Q Case Supporter Lock Button Case Supporter CREED The desorption of case must be done under no pressure DPush the red lock button down to the direction where the OPEN arrow indicates Turn case supporter to the left and pull it down Case supporter and case guard are disconnected Pull case out Remove the bottom thread of retainer with screwdriver Remove retainer amp element lInstall the new element amp retainer and fix them with the thread Screw it up completely Put case guard into case supporter and then put case into case guard Set them to main body with putting lock button and groove of main body together Press case supporter up so that there is no gap with main body Turn it to the right until lock button co
12. piping lifetime If that happens attach a filter as indicated in 1 and 2 below With the FDT a fi Iter is already supplied 1 Be sure to attach a micro mist filter with filtration capability of 5 wm or ess to any line of piping which dose not h 2 Attach a filter with 10 um or so filtration if the line has oil mist protection ave oil mist protection capability DMP DMM or DMB For any line requiring a pressure adjustment or luburication install a regulator lubricator after the dryer 8 4 0pen the valve 1 V 1 In case that the purging flow is too much it is possible to decrease the purging to the circuit 1 flow as follows However the temperature of the dew point arises a little bit In case of the circuit 3 set the dial to the circuit 2 and in case of the circuit 2 circuit8 circuite Purging flow is reduced to a half circuite circuit1 Purging flow is reduced to a half about 1 4 of circuit 3 Case That Requested Dehumidifing Effect s i Unable To Be Obtained A lsn t the purging line closed lsn t the back pressure put on the purging line ls there any obstacles in the outlet Doesn t the drain in the compressed air come into Fiber Dry directly Due to the drying by the hollow fiber film the dorp is unable to be removed Ir case that requested dehumidifing effect is unable to be obtained even if the above three points are clear inc
13. rease the purging flow Please refer to the following which shows the mutual relation between the operating condition and the dryness Relation between Dryness and Operating Conditions Make a most efficient use of Fiber Dry in considering of the data given below w ai Dryness High Supplying Air Pressure High Dryness G pal Low High Supplying Air Flow Rate E w siie Dryness Low High Supplying Air Temperature High Dryness Low High LOW Purging Flow The durability of Fiber Dry depends on the operation temperature and the blinding by oil or dust After confirming the condition of specifications and the piping method completely please operate it The criterion of the time to exchange Fiber Dry is able to be confirmed with the following piping Differential Pressure Gauge P po 6 Time To Exchange or O Fiber Dry O Fiber Dry P1 P2 Pressure Difference The criterion of exchange is the condition that the difference of pressure increases by 0 5 0 8kgf cm from the initial value In case of FDT 100 0O 0 It is possible that the difference of pressure will be restored after exchanging the filter element the organic solvent Do not inflict the excessive pressure temperature shock etc Do not let the dust drop rust come into the inside ee Since in principle it sould be operated indoors av

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書『補足説明』  MSI H61I-E35 V2/W8 motherboard  「Lino Ag + 」カタログ  girton cabinet washer/dryer model 80-0d-hp  Agilent Technologies 33220A User's Manual  AQUALAND GRAPH Ver.2  NFC  Gebrauchsanleitung Instruction manual Mode d`emploi Handleiding  Harting HAN 3A RJ-45 Panel Feed-through, Metalen uitvo  Merulex IFA - Sika Guatemala SA  