Home
        nPL Series Instruction Manual - Issue 2
         Contents
1.                             WARNING  Such voltages are exceedingly hazardous and great care should be taken to shield  the output terminals for such use  On no account should the output terminals be touched when  the unit is switched on under such use  All connections to the terminals must be made with the  power switched off on all units     It should be noted that the unit can only source current and cannot sink it  thus units cannot be  series connected in anti phase     10    The unit can be connected in parallel with others to produce higher currents  Where several units  are connected in parallel  the output voltage will be equal to that of the unit with the highest output  voltage setting until the current drawn exceeds its current limit setting  upon which the output will  fall to that of the next highest setting  and so on  In constant current mode  units can be  connected in parallel to provide a current equal to the sum of the current limit settings     Protection    The output has intrinsic short circuit protection and is protected from reverse voltages by a diode   the continuous reverse current must not exceed 3 Amps  although transients can be much higher   If the applied reverse voltage can source more current than the set current limit  and the output is  on  then the output will go into current limit  the CC indicator will flash  and its display will show   the reverse voltage across the protection diode  if the output is off  just the CC indicator will flas
2.       BLU MARRONE BLU MARRONE    4  Riassemblare eseguendo la stessa operazione in ordine inverso  Per la conformit   ai  requisiti di sicurezza standard  la tensione di esercizio segnata sul pannello posteriore deve  essere modificata e sostituita con la nuova tensione     Fusibile    Il fusibile elettrico    ubicato nel cassettino apposito  nella parte inferiore del connettore IEC  interno  Per cambiare il fusibile  rimuovere il cavo d alimentazione e aprire il cassetto del fusibile  con uno strumento adatto  Il tipo corretto di fusibile    20 x 5mm 250V HBC ritardato con la  seguente potenza     230V 115V  Singolo  1 6A  T  3 15A  T   Duale  3 15A T  6 3A T     Accertarsi di utilizzare solo i fusibili della potenza e del tipo prescritti per eventuali sostituzioni   L uso di fusibili improvvisati e la cortocircuitazione del portafusibili    vietato     Cavo di alimentazione    36    Collegare lo strumento all alimentazione AC utilizzando il cavo di alimentazione fornito  Se     necessaria una spina di alimentazione per uno zoccolo diverso     necessario utilizzare un cavo  adatto e approvato  con spina a muro e connettore IEC60320 C13 per il collegamento con lo  strumento  Per determinare la portata corretta del set di cavi per l alimentazione AC desiderata   fare riferimento alle informazioni sull attrezzatura e alle Specifiche     AVVERTENZA  LO STRUMENTO DEVE ESSERE PROVVISTO DI MESSA A TERRA     Qualsiasi interruzione del conduttore di messa a terra dell   alimentazione
3.       Entretien    Le Constructeur ou ses agents    l   tranger r  pareront tout bloc qui tombe en panne  Si le  propri  taire de l appareil d  cide d effectuer ses propres r  parations  ceci doit uniquement   tre  effectu   par un personnel sp  cialis   qui doit se r  f  rer au manuel de r  visions que l on peut se  procurer directement aupr  s du Constructeur ou de ses agents    l   tranger     Nettoyage    24    S il faut nettoyer le bloc d alimentation  utiliser un chiffon l  g  rement imbib   d eau ou d un  d  tergent doux  Nettoyer le cadran d affichage au moyen d un chiffon sec et doux     AVERTISSEMENT  EMPECHER TOUTE INTRODUCTION D EAU DANS LE BOITIER AFIN  D EVITER TOUT CHOC ELECTRIQUE ET DEGATS AU BLOC D ALIMENTATION  NE JAMAIS  UTILISER DE DISSOLVANTS POUR NETTOYER LE BLOC  AFIN D EVITER  D ENDOMMAGER LE BOITIER OU LE CADRAN D AFFICHAGE     Sicherheit    Dieses Ger  t wurde nach der Sicherheitsklasse  Schutzart    der IEC Klassifikation und gem      den europ  ischen Vorschriften EN61010 1  Sicherheitsvorschriften f  r elektrische Mess    Steuer   Regel  und Laboranlagen  entwickelt  Es handelt sich um ein Gerat der  Installationskategorie II  das fur den Betrieb von einer normalen einphasigen Versorgung  vorgesehen ist     Das Ger  t wurde gem     den Vorschriften EN61010 1 gepr  ft und wurde in sicherem Zustand  geliefert  Die vorliegende Anleitung enth  lt vom Benutzer zu beachtende Informationen und  Warnungen  die den sicheren Betrieb und den sicheren Zustand
4.      Einstellungen f  r die Verriegelung  Durch Dr  cken der Taste LOCK wird die Strom  und Spannungsbegrenzung digital verriegelt  Die  Einstellungen werden mit hoher Genauigkeit  besser als 1 Stelle  bei absoluter Stabilit  t  gespeichert  Anschlie  ende Ver  nderungen der Regler VOLTAGE und CURRENT bleiben  wirkungslos   Da eine Annullierung von LOCK zu einer   nderung der Ausgangseinstellungen f  hren w  rde   falls die Einstellung f  r VOLTAGE und CURRENT in der Zwischenzeit ver  ndert wurde    erscheint eine Warnmeldung bevor die Funktion LOCK annuliert wird     Hierzu die Taste gedr  ckt halten  um LOCK zu annullieren     Bei abgeschaltetem Ausgang  sicherer Zustand  blinken die  unverriegelten    Einstellungen  zweimal kurz im Display auf  bevor die   nderung durchgef  hrt wird  Die LOCK Leuchte geht  dann aus     Wenn der Ausgang noch eingeschaltet ist blinkt die Meldung OP  on  Ausgang Ein  zweimal im Display auf  Anschlie  end werden  die neuen    unverriegelten    Einstellungen 2 bis 3 Sekunden lang  angezeigt  zuerst langsam  dann schneller   bevor die   nderung  schlie  lich durchgef  hrt wird     Die LOCK Anzeige geht aus  sobald die   nderung erfolgt ist  Beim Loslassen der Taste LOCK   w  hrend das Display blinkt  wird die Deaktivierung der LOCK Funktion abgebrochen        Die   nderung des Strombegrenzungsbereichs  siehe     Einrichten des Ausgangs     bzw  des  Spannungsbegrenzungsbereichs  siehe  Spannungsbereich     bei aktivierter LOCK Funktion ist  nich
5.     C  Current  typically  lt  100ppm   1mA    C     100ppm   0 1mA    C on 500mA range   Output will withstand forward voltages of up to 20V above rated output  voltage  Reverse protection by diode clamp for currents up to 3A     Output trips off for over temperature     METER SPECIFICATIONS    Display Type   Voltage     Current     Current Meter Average     Independent Mode     Tracking Mode     Tracking Accuracy   Ratio     Tracking Mode     Tracking Accuracy   Parallel Mode     Both On   Both Off     GENERAL    AC Input    Power Consumption   Operating Range   Storage Range   Environmental   Cooling     Safety   EMC   Size     Weight     Dual 4 digit meters  10mm  0 39   LED     Resolution 10mV   Accuracy    0 1  of reading   10mV    Resolution 1mA  0 1mA on 500mA range    Accuracy    0 3    3mA  to 3A     05    3mA  to 6A       03    0 3mA  on 500mA range    Selects a 2s time constant  normally 20ms  for averaging of rapidly  varying load currents     ADDITIONAL SPECIFICATIONS   PL303QMD QUAD MODE DUAL    Each output is fully independent and isolated  Operation is equivalent to  two single power supplies    The two outputs remain isolated but the Slave voltage controls are  disabled and the Slave voltage is set equal to the Master voltage    Slave voltage     0 1  of Master voltage setting  10mV     As tracking but the Slave voltage controls set an output voltage between  0  and 101  of the Master voltage  Once set  varying the Master voltage  will create the same percen
6.    THURLBY THANDAR INSTRUMENTS       New PL Series  PRECISION LINEAR DC POWER SUPPLIES    INSTRUCTION MANUAL    Introduction    The original PL series set a new benchmark for DC laboratory power supplies when it was  introduced in 1980 and has since been extensively copied by other manufacturers     Its key features were     Linear regulation for ultra low output noise and fast transient recovery   High accuracy four digit fixed resolution meters   True analogue controls for quick and intuitive adjustment of voltage and current  DC output switch to check settings before applying them   Remote voltage sensing for exceptional load regulation   Current meter averaging to reduce jitter with rapidly varying load currents    The New PL series retains all the key aspects of the original PL series but combines them with  new and important features     Introduction    High power density   up to 90 watts from an ultra compact 3U   rack case size    Significantly higher energy efficiency than conventional linear regulated designs by using  an advanced phase controlled pre regulator    Low current range giving 0 1mA meter resolution and finer low current setting    V Span allows the user to redefine the end stop values of the voltage control  giving high   resolution analogue control over the exact voltage range needed    S Lock digitally locks voltage and current settings at the touch of a button  Setting limits can be viewed at any time    Safety binding post terminals are touch proof 
7.   WARNUNG  ZUR VERMEIDUNG EINES ELEKTRISCHEN SCHLAGS BZW  BESCH  DIGUNG  DER STROMVERSORGUNGSEINHEIT  DAF  R SORGEN  DASS KEIN WASSER INS  GEH  USE EINDRINGT  UM SCHADEN AM GEH  USE BZW  AM ANZEIGEFENSTER ZU  VERMEIDEN  KEINE L  SUNGSMITTEL ZUR REINIGUNG VERWENDEN     Sicurezza    Questo strumento appartiene alla Categoria di Sicurezza 1  secondo la classifica IEC  ed    stato  progettato in modo da soddisfare i criteri EN61010 1  requisiti di Sicurezza per Apparecchiature  di misura  controllo e per uso in laboratorio      uno strumento di Categoria d   installazione Il ed     inteso per il funzionamento con un alimentazione normale monofase     Questo strumento ha superato le prove previste da EN61010 1 e viene fornito in uno stato di  sicurezza normale  Questo manuale contiene informazioni e avvertenze che devono essere  seguite per assicurare un funzionamento sicuro e mantenere lo strumento in condizioni di  sicurezza    Questo strumento    progettato per uso all   interno e in un ambiente d inquinamento Grado 2  entro  la gamma di temperatura da 5  C a 40C    con umidit   relativa  non condensante  di   20    80   Pu   occasionalmente essere assoggettato a temperature fra  5  C e  10  C senza  comprometterne la sicurezza  Non usare in presenza di condensazione     L uso dello strumento in maniera non conforme a quanto specificato in queste istruzioni potrebbe  pregiudicare la protezione di cui    dotato  Non usare lo strumento per misurare tensioni al di  sopra dei valor
8.  46    Conecte el instrumento a la fuente de alimentaci  n de CA mediante el cable de red que se  suministra  Si se necesita un enchufe para una toma de corriente de tipo distinto  se debe utilizar  un cable homologado y con la clasificaci  n adecuada  que tendr   en un extremo el conector  correspondiente a la toma de pared  y un conector IEC60320 C13 en el extremo del instrumento   Para determinar la gama de corriente m  nima del cable de alimentaci  n de CA  consulte la  informaci  n sobre gamas de corriente en el equipo o las especificaciones     ADVERTENCIA ESTE INSTRUMENTO SE DEBE CONECTAR A TIERRA     Cualquier interrupci  n del conductor de puesta a tierra  dentro o fuera del instrumento  har   que    ste resulte peligroso  Est   prohibida la interrupci  n intencionada     Montaje    El instrumento podra utilizarse montado en banco de trabajo y en bastidor  Un kit para el montaje  en un estante de 48 cm puede obtenerse de los fabricantes o de sus agentes en el extranjero     Ventilacion    El suministro de corriente es enfriado mediante un ventilador de multiple velocidad inteligente  que facilita la convecci  n vertical  Tenga cuidado de no restringir las entradas de aire debajo de  los respiraderos de la parte superior  Si el instrumento esta montado en bastidor  deje suficiente  espacio por encima y debajo del instrumento y   o utilice una placa ventiladora para enfriado a  presi  n     Conexiones    Todas las conexiones se hacen desde el panel frontal     La carga
9.  CC en el momento de la conexi  n puede ser  ajustado a    siempre apagada    o    igual que en la ultima desconexi  n     El  ajuste puede ser cambiado como sigue  Con la tecla VIEW  visualizar   pulsada  presione y mantenga presionada la tecla OUTPUT  salida          el visualizador mostrar   primero el ajuste actual durante 1 segundo    OP OFF si todav  a est   seleccionado el ajuste por defecto  antes de  parpadear el nuevo ajuste durante 2 segundos   LASt Set en este  caso   Despu  s de 2 segundos  el nuevo ajuste se muestra  continuamente en el visualizador y el cambio es implementado  suelte las  teclas OUTPUT  salida  y VIEW  visualizar      Repitiendo este proceso se cambiar   el ajuste de nuevo a su estado previo  Tenga en cuenta  que las dos salidas del suministro doble deben ser ajustadas de manera individual     Control de la salida       Con el interruptor POWER encendido y la OUTPUT  salida        apagada  el voltaje de salida y  el l  mite de corriente pueden ser previamente establecidos con precisi  n usando los controles  VOLTAGE  voltaje  y CURRENT  corriente   el contador de la izquierda muestra el voltaje  establecido  el contador de la derecha muestra la m  xima corriente establecida y el indicador de  SETTINGS  ajustes  se enciende    Al conmutarse el interruptor de salida  el indicador OUTPUT se enciende  el contador de la  izquierda muestra ahora el voltaje real y el contador de la derecha la corriente de carga real     El l  mite superior del control
10.  CURRENT puede ser conmutado  entre el m  ximo para este modelo y 500mA con pulsaciones  alternativas de la tecla RANGE  gama  de 500mA para aportar un  ajuste de l  mite de corriente y una resoluci  n de medici  n m  s  precisos  0 1mA hasta 500mA      Para cambiar la gama de l  mite de corriente la salida debe estar desactivada  si la salida est    activada  el mensaje de aviso turn oFF se visualiza brevemente en la pantalla  el indicador  OUTPUT parpadea y la gama permanece inalterada     Voltaje constante    El voltaje de salida es ajustado usando los controles de VOLTAGE principal y preciso  el control  de CURRENT establece la corriente m  xima que puede ser suministrada     Corriente constante    48    Si la resistencia de carga es lo suficiente baja de modo que  al voltaje de salida establecido   fluir  a una corriente superior al ajuste del limite de corriente  el suministro el  ctrico pasar    autom  ticamente a funcionamiento en corriente constante  La salida de corriente es ajustada  mediante el control de CURRENT mientras que los controles de VOLTAGE establecen el voltaje  m  ximo que puede ser generado    El indicador de CC se enciende para mostrar funcionamiento en corriente constante        Salida de corriente instantanea    El control de limite de corriente se puede ajustar para limitar la corriente de salida continua a  niveles de hasta 1mA  0 1mA en una gama de 500mA   Sin embargo  com  nmente a todos los  suministros de corriente en banco de precisi  n  un 
11.  Die untere Spannungsgrenze wird mit den Reglern MAIN und FINE VOLTAGE exakt auf den  gew  nschten Wert gesetzt     dann die Taste Vmin gedr  ckt halten  bis das  V  Display auf der  linken Seite aufh  rt zu blinken und das Display auf der rechten Seite  mA  Set zeigt  Die    Einstellung kann durch kurzes Dr  cken   lt  1 Sekunde  der Taste Vmin eingesehen werden  Die  obere Spannungsgrenze kann mittels des VOLTAGE Regler und der Taste Vmax auf gleiche  Weise eingestellt und kontrolliert werden    Die Grenzwerte k  nnen in beliebiger Reihenfolge und innerhalb des Ausgangsbereichs des  Ger  ts auf einen beliebigen Wert gesetzt werden   allerdings kann V Span mit der Taste ENABLE  nur dann aktiviert werden  wenn Vmax 2  Vmin   0 1 V   Ist dies nicht gegeben  so erscheint kurz  die Meldung Set Err und die Funktion V Span wird nicht aktiviert    Bei aktivierter V Span Funktion umfasst der Regelbereich f  r den MAIN VOLTAGE Regler genau  Vmin DIS Vmax wenn sich der FINE Regler in der Mittenstellung befindet  auf dem Ger  t mit einem    e markiert   Mit dem FINE Regler kann eine zus  tzliche Feinabstimmung von   1   des  Spannungsbereichs  vorgenommen werden     DEIIEDSANEN des nee  Quad Mode Dual        ___ISOLATED TRACKING  4  Im folgenden werden die vier Betriebsarten dieses    Doppelnetzgerats beschrieben  Die Einstellung der Betriebsart  erfolgt mit dem MODE Drehschalter  Damit an den  angeschlossenen Schaltungen keine unvertraglichen  Spannungen anliegen  werden beim Wechsel 
12.  REMOTE    Per evitare instabilit   e problemi di risposta transiente  bisogna fare attenzione a garantire un  buon accoppiamento tra ogni uscita e il cavo del sensore  Ci   si pu   eseguire sia intrecciando i  cavi sia utilizzando cavi coassiali schermati  sensore su quello interno   Un capacitore elettrolitico  direttamente sul punto di connessione di carico potrebbe essere di aiuto  La caduta di tensione   in ciascun cavo d uscita non deve superare gli 0 5 Volt     Ruotare lo switch LOCAL REMOTE di nuovo su LOCAL quando il sensore remoto non    in  funzione   Connessioni parallele e in serie con altre uscite    Le uscite dell   alimentatore sono completamente libere e possono essere utilizzate in serie con  altre unit   di alimentazione per generare tensioni DC che arrivano fino a 300V DC                                                        VAN La tensione massima possibile tra i terminali e la messa a terra  by    300V DC    AVVERTENZA  Tali tensioni sono molto pericolose e bisogna prestare molta attenzione a  schermare i terminali d   uscita  per questo utilizzo    terminali d uscita non devono essere in  nessun caso toccati quando l unit      attivata per questo utilizzo  Tutte le connessioni ai terminali  devono essere realizzate con l alimentazione disattivata in tutta l   unit          39    Si noti che l   unit   pu   solo fornire corrente  e non riceverla  e di conseguenza le unit   non  possono essere collegate in serie in antifase     L unit   pu   essere conne
13.  abwechselndes Dr  cken der RANGE Taste zwischen dem  Maximalwert f  r dieses Ger  t und 500 mA umgeschaltet werden  um  so eine Feineinstellung der Strombegrenzung und der Messaufl  sung   0 1 mA bis zu 500 mA  zu erreichen     Die Anzeige neben der Taste leuchtet auf  wenn der 500 mA Bereich gew  hlt ist  Um den  Strombegrenzungsbereich   ndern zu k  nnen  muss der Ausgang abgeschaltet werden   sollte  der Ausgang noch eingeschaltet sein  erscheint kurz die Meldung turn oFF im Display  die  OUTPUT Anzeige blinkt und der Bereich bleibt unver  ndert     Konstantspannung    Die Ausgangsspannung wird mit den VOLTAGE Grob  und Feinreglern geregelt  mit dem Regler  CURRENT wird der Maximalstrom eingestellt     Konstantstrom    28    Wenn der Lastwiderstand so niedrig ist  dass bei der gew  hlten Ausgangsspannung ein h  herer  Strom flie  en w  rde  als durch die Strombegrenzung vorgegeben  so schaltet das Netzger  t  automatisch auf Konstantstrombetrieb  Der Ausgangsstrom wird mit dem CURRENT Regler  eingestellt  w  hrend die VOLTAGE Regler die maximal erzeugte Spannung bestimmen    Die Konstantstromanzeige  CC  leuchtet auf  um den Betrieb mit Konstantstrom anzuzeigen     Momentanstrom    Mit Hilfe der Strombegrenzungsfunktion kann der Dauerausgangsstrom bis auf 1 mA herab  begrenzt werden  0 1 mAim 500 mA Bereich   Wie bei allen Prazisionsnetzgeraten wird jedoch  auch hier ein Kondensator am Ausgang parallel geschaltet  um eine stabile Ausgangsspannung  und ein gutes dynamische
14.  bereitzustellen     Schutzvorrichtungen    Der Ausgang ist eigensicher gegen Kurzschl  sse und zus  tzlich durch eine Diode gegen  R  ckspannung gesch  tzt  Diese R  ckspannung darf 3 Ampere nicht   berschreiten  Stromspitzen  d  rfen erheblich h  her liegen   Falls die anliegende R  ckspannung mehr Strom abgibt  als durch  die Strombegrenzung eingestellt ist  schaltet der Ausgang  sofern aktiviert  auf Strombegrenzung   CC Anzeige blinkt  und zeigt im Display die R  ckspannung an der Schutzdiode an  Ist der  Ausgang deaktiviert  so blinkt lediglich die CC Anzeige     Wie alle seriengeregelten  unsymmetrischen Netzger  te kann auch dieses Ger  t nicht  stromziehend arbeiten  Wird eine Spannung von einer externen Quelle angelegt  die h  her liegt  als die eingestellte Ausgangsspannung  so schaltet sich die interne Regelung ab  sodass keine  Strom mehr flie  en kann  Wenn der Ausgang eingeschaltet ist zeigt das Messinstrument die  angelegte Spannung an  Eine Besch  digung findet nicht statt  vorausgesetzt die angelegte  Spannung   berschreitet die maximale Ausgangsspannung des Netzger  ts um nicht mehr als 20  Volt     Bei ausgeschaltetem OUTPUT und weiterhin angeschlossener Last wird die Ausgangsspannung  einfach auf Null gesetzt  Legen Sie keine externen Spannungen an den Klemmen des Netzger  ts  an  die mehr als 20 V   ber der Nennausgangsspannung liegen  da sonst selbst bei  ausgeschaltetem Ausgang Sch  den m  glich sind       bertemperaturschutz    30    Ein integrierter 
15.  by the resistance of the  connecting leads  At higher currents this can result in significant differences between the    indicated source voltage and the actual load voltage  two 20mQ connecting leads will drop 0 2V  at 5 Amps  for instance          This problem can be minimised by using short  thick  connecting  leads  but where necessary it can be completely overcome by  using the remote sense facility                       ni This requires the sense terminals to be connected to the output     toca  Remote at the load instead of at the source  insert wires into the spring    SENSE  loaded SENSE terminals and connect directly to the load  Switch  nn the LOCAL REMOTE switch to REMOTE     To avoid instability and transient response problems  care must be taken to ensure good coupling  between each output and sense lead  This can be done either by twisting the leads together or by  using coaxially screened cables  sense through the inner   An electrolytic capacitor directly  across the load connection point may also be beneficial  The voltage drop in each output lead  must not exceed 0 5 Volts   Switch the LOCAL REMOTE switch back to LOCAL when remote sensing is not in use    Series or Parallel Connection with Other Outputs    The outputs of the power supply are fully floating and may be used in series with other power  supply units to generate high DC voltages up to 300V DC   L    ZAN The maximum permissible voltage between any terminal and earth ground     is 300VDC         
16.  debe conectarse a los terminales OUTPUT  Salida  positivo  rojo  y negativo  negro    Ambas son totalmente flotantes y cualquiera de ellas puede ser conectada a tierra     Las conexiones a la carga de detecci  n remota  si son requeridas  se efectuan desde los  terminales     SENSE  detecci  n remota  positivos     y negativos      Sit  e el interruptor  LOCAL REMOTE  local   remoto  en REMOTE si requiere detecci  n remota  Vuelva a situarlo en  LOCAL si no usa detecci  n remota     El terminal an se conecta al bastidor y a la toma de tierra de seguridad     47    Funcionamiento    En este manual  las teclas  controles y tomas del panel frontal se ilustran en may  sculas  e g   CURRENT  OUTPUT  LOCK   los mensajes visualizados en los LED de 7 segmentos se ilustran  en letra diferente  e g  turn oFF  OtP trip  Las caracteristicas adicionales del  instrumento doble de modo cu  drupole  Quad mode Dual  se describen juntas al final de este  capitulo     Encendido y condiciones de energizaci  n       El interruptor de POWER  energia  esta situado en la parte inferior izquierda del panel frontal  Al  situar el interruptor POWER  energia  en  I    el medidor derecho indica brevemente la revisi  n  del soporte l  gico antes de que el visualizador muestre los voltios y amperios     En el momento de la conexi  n  el ajuste en fabrica por defecto es con la salida apagada  Todos  los demas ajustes seran los utilizados en el momento de la ultima desconexi  n     El estado de la salida de
17.  des Ger  tes gew  hrleisten     Dieses Ger  t ist f  r den Betrieb in Innenr  umen der Umgebungsklasse 2   f  r einen  Temperaturbereich von  5   C bis  40   C und 20   80   relative Feuchtigkeit  nicht  kondensierend  vorgesehen  Gelegentlich kann es Temperaturen zwischen  10  C und  5  C  ausgesetzt sein  ohne dass seine Sicherheit dadurch beeintr  chtigt wird  Betreiben Sie das Ger  t  jedoch auf keinen Fall  solange Kondensation vorhanden ist     Ein Einsatz dieses Ger  tes in einer Weise  die f  r diese Anlage nicht vorgesehen ist  kann die  vorgesehene Sicherheit beeintr  chtigen  Auf keinen Fall das Ger  t au  erhalb der angegebenen  Nennversorgungsspannungen oder Umgebungsbedingungen betreiben     WARNUNG    DIESES GER  T MUSS GEERDET WERDEN     Jede Unterbrechung des Netzschutzleiters innerhalb oder au  erhalb des Ger  tes macht das  Ger  t gef  hrlich  Eine absichtliche Unterbrechung ist verboten  Die Schutzwirkung darf durch  Verwendung eines Verl  ngerungskabels ohne Schutzleiter nicht aufgehoben werden     Ist das Ger  t an die elektrische Versorgung angeschlossen  so k  nnen die Klemmen unter  Spannung stehen  was bedeutet  da   beim Entfernen von Verkleidungs  oder sonstigen Teilen   mit Ausnahme der Teile  zu denen Zugang mit der Hand m  glich ist  h  chstwahrscheinlich  spannungsf  hrende Teile blo  gelegt weden  Vor jeglichem   ffnen des Ger  ts zu Nachstell    Auswechsel   Wartungs  oder Reparaturzwecken  dieses stets von s  mtlichen Spannungsquellen  abkl
18.  desconectado de la fuente de alimentaci  n de CA     2  Retire el remache de pl  stico de cada borde lateral de la cubierta superior  Suelte los  remaches haciendo palanca con la punta de un destornillador peque  o y  a continuaci  n   ret  relos por completo  Retire los dos tornillos del panel trasero que sujetan la cubierta  superior  deslice hacia atr  s la cubierta para levantarla y sacarla     3  Cambie las conexiones del transformador  dos transformadores en salida doble   observando el diagrama siguiente     230V Operation 115V Operation       AZUL MARR  N AZUL MARR  N    4  Realice los pasos anteriores en orden inverso para volver a montar la carcasa  Para cumplir  los requisitos de las normas de seguridad  es necesario cambiar la tensi  n que figura en el  panel trasero  con el fin de que refleje el ajuste actual     Fusible    El fusible de CA est   en el caj  n de fusibles situado en la parte inferior del conector de entrada  IEC  Para cambiar el fusible  retire el cable de l  nea y abra el caj  n de fusibles con una  herramienta adecuada     El tipo de fusible correcto es 20 x 5mm 250V HBC tiempo retardado con las capacidades  siguientes     115V  Sencillo  1 6A  T  3 15A  T   Doble  3 15  T  6 3A  T     Aseg  rese de que  cuando sea necesaria una sustituci  n  se utilicen   nicamente fusibles de la  corriente nominal y el tipo especificados  Est   prohibido utilizar fusibles provisionales  as   como  cortocircuitar los portafusibles     Cable de alimentaci  n   
19.  describe previamente  Sin embargo  el limite de  corriente ajustado real de la Maestra todavia ser   doble  conmutando de Seguimiento a Paralelo   o la mitad  conmutando de Paralelo a Seguimiento   incluso si LOCK est   ajustado  pero el  visualizador de corriente parpadea como aviso de que ha ocurrido esto     Ajustes de Esclava retenidos    Si se activa V Span en la salida Esclava en modo INDEPENDENT  se desactivar   al seleccionar  el modo TRACKING pero volver   a activarse al volver a seleccionar el modo INDEPENDENT    Si se activa Ratio     Tracking  Seguimiento     de proporci  n  en el modo TRACKING de  salida Esclava  se desactivara al seleccionar INDEPENDENT o PARALLEL pero volver   a  activarse al volver a seleccionar el modo TRACKING     Control de apagado   encendido de salida simultaneo       Las teclas Both On   Both Off  ambas apagadas   ambas  encendidas  son adicionales a los conmutadores de OUTPUT   salida  individuales y permiten encender o apagar ambas salidas  de manera sincrona con una sola pulsaci  n de tecla  Las teclas  Both On   Both Off funcionan en los cuatro modos de  configuraci  n     Mantenimiento    Los fabricantes o sus agentes en el extranjero ofrecen un servicio de reparaci  n para toda  unidad que desarrolle un defecto  Si los propietarios desearan establecer su propio servicio  esto  s  lo debe realizarse por personas cualificadas en conjunto con el manual de servicio que puede  adquirirse directamente del Fabricante o de sus agentes en 
20.  e en  utilisant l int  gralit   de la rotation    300    des commandes de tension        V Span est activ   ou d  sactiv      l   aide de la touche  ENABLE  Lindicateur ENABLE est allum   lorsque  V Span est s  lectionn    La valeur d usine par d  faut est    Vmin   3V  Vmax   5V    Dans la mesure o   l activation de V Span modifiera toujours la tension de sortie  cette option ne  peut   tre activ  e ou annul  e que si la sortie est d  sactiv  e   toute tentative d activation ou  d   annulation de V Span alors que la sortie est affich  e provoque l apparition rapide du message  turn oFF invitant l utilisateur    d  sactiver la sortie     Pour d  finir de nouvelles valeurs pour Vmin OU Vmax la fonction V Span doit   tre d  sactiv  e   annul  e     La limite inf  rieure de tension est d  finie a l aide des commandes MAIN et FINE VOLTAGE qui  permettent de choisir exactement la valeur requise   la touche Vmin est alors maintenue enfonc  e    21    jusqu    ce que l affichage de gauche  V  cesse de clignoter et que l affichage de droite  mA   indique Set  Le param  tre peut   tre affich   a tout moment par une br  ve pression   lt 1 seconde     sur la touche Vmin  La limite de tension sup  rieure est d  finie et affich  e exactement de la m  me  mani  re a l aide des commandesVOLTAGE et de la touche Vmax     Les limites peuvent   tre r  gl  es dans n importe quel ordre et sur n importe quelle valeur situ  e  dans la plage de sortie de l instrument  mais V Span peut uniquement   
21.  en la secci  n  Amplitud de voltaje de Esclavaampara  ENABLE encendida        El instrumento funciona como se describe arriba para el modo de Seguimiento pero el voltaje de  Esclava puede ajustarse a un porcentaje  0  a 101   del voltaje de la Maestra usando los  controles de voltaje de la Esclava  La proporci  n es luego mantenida al variar el voltaje de la  Maestra    AI pulsar de nuevo ENABLE se retorna la Esclava al modo de Seguimiento estandar  lampara  ENABLE apagada     El seguimiento de proporci  n solamente puede activarse o desactivarse con la salida apagada   Si la salida est   encendida  el visualizador mostrar   brevemente el mensaje turn oFF cuando  se pulsa ENABLE y el cambio no ser   implementado    Siempre que se activa el modo de Seguimiento de proporci  n de aislamiento el visualizador de la  Esclava muestra moment  neamente Pent on antes de volver a mostrar el voltaje de salida real  ahora ajustado     El valor en porcentaje puede mostrarse en cualquier momento pulsando la tecla Vmin 0 la Vmax  de la salida Esclava  Con cualquiera de estas teclas pulsada  el visualizador de la Esclava  muestra el ajuste del porcentaje en la forma de 90 0 Pent y los controles del voltaje de la  Esclava pueden ser usados para ajustar el porcentaje proporcional requerido  El porcentaje  proporcional puede ser ajustado antes de activar el Seguimiento de la Esclava  lampara ENABLE  apagada     Las funciones LOCK y VOLTAGE SPAN de la Maestra funcionan exactamente como se descri
22.  igual a la suma de los ajustes de l  mite de corriente     Protecci  n    La salida est   intrinsicamente protegida contra cortocircuitos y voltajes inversos mediante un  diodo  La corriente inversa continua no debe exceder 3 amperios  si bien las transitorias pueden  ser mucho m  s altas  Si el voltaje inverso aplicado puede originar m  s corriente que el l  mite de  corriente establecido  y la salida est   activada  la salida pasar   a l  mite de corriente  el indicador  de CC parpadear    y su pantalla visualizar   el voltaje inverso a trav  s del diodo de protecci  n  Si  la salida est   desactivada  solamente parpadear   el indicador de CC      Al igual que todos los suministros de corriente de un solo frente regulados en serie  la unidad no  es capaz de degradar la corriente suministrada de una fuente externa  Si un voltaje superior al  del voltaje de salida establecido de la unidad es aplicado desde una fuente externa  el regulador  interno se desactivar   y no fluir   corriente alguna  Si la salida es activada  el contador de voltaje  visualizar   el voltaje aplicado  No se causar   da  o alguno siempre que el voltaje aplicado no  sea superior al voltaje de salida m  ximo del suministro de corriente en m  s de 20 voltios     Con la OUTPUT desactivada  la carga todav  a estar   conectada a la fase de salida de suministro  de corriente  El voltaje de salida simplemente se establece en cero  No aplique voltajes  externos a los terminales de suministro de corriente super
23.  interno o esterno allo  strumento  lo render   pericoloso  E vietata qualsiasi interruzione intenzionale     Montaggio    Questo strumento pu   essere montato su banco o a muro  Un kit per montaggio su scaffale di  19       disponibile presso il Produttore o le sue rappresentanze estere     Ventilazione    L alimentazione elettrica viene raffreddata da una ventola intelligente a pi   velocit   che coadiuva  la convezione verticale  Fare attenzione a non coprire le prese d   aria in basso o le ventole nella  parte superiore  Una volta montato a muro  lasciare sopra e sotto lo strumento lo spazio per una  adeguata ventilazione e o utilizzare un cassetto di ventilazione per ventilazione forzata     Connessioni    Tutte le connessioni si trovano sul pannello frontale     Il carico deve essere connesso ai terminali positivo  rosso  e negativo  nero  con la scritta  OUTPUT  Entrambi sono completamente liberi e possono essere connessi a terra     Connessioni a sensori remoti alla tensione di carico  se necessarie  vengono eseguite dai  terminali a SENSE  sensori  positivo     e negativo      Ruotare lo switch LOCAL REMOTE   LOCALE REMOTO   su REMOTE  remoto  quando si desidera utilizzare i sensori remoti  In  caso contrario  tornare su LOCAL  locale      L    Il terminale con la scritta      connesso alla terra dello chassis e alla messa a terra     37    Funzionamento    Nel presente manuale  i tasti e gli zoccoli sul pannello frontale sono riportati in maiuscolo  ad  esempio CURR
24.  limiter l intensit   de sortie continue    des  niveaux descendant jusqu   a 1mA  0 1 mA sur une plage de 500 mA   Cependant  commun  ment  a tous les g  n  rateurs de pr  cision d     tabli  un condensateur est connect   sur la sortie pour  conserver la stabilit   et une bonne r  ponse aux d  fauts transitoires  Ce condensateur se charge  sur la tension de sortie et le chargement de la sortie produira une impulsion d   intensit      la  d  charge du condensateur  ce qui ne d  pend pas du r  glage de limite d intensit       Moyenne actuelle du m  tre    Pour r  duire les sautillements avec des courants de charge  variant rapidement  il est possible de s  lectionner une constante  d une dur  e de 2 secondes en appuyant sur la touche METER  AVERAGE   l indicateur situ   a c  t   de la touche s allume lorsque  la moyenne du m  tre est s  lectionn  e           Appuyez de nouveau sur la touche pour CANCEL  annuler  la moyenne du m  tre et revenir a la  constante de temps standard de 20 ms     Economie    Le module d alimentation minimise la dissipation en utilisant une pr   r  gulation   lectronique afin  de conserver une tension maximale faible pour les condensateurs de sortie  En outre  pour  optimiser le fonctionnement a des niveaux extr  mes de tension d entr  e et de puissance de  sortie CC  le transformateur secondaire est intelligemment remplac   par un relais  L hyst  r  sis  est utilis  e au point de seuil pour emp  cher un basculement inutile lorsque la sortie est d  fi
25.  lira la  tension appliqu  e  Cela ne produira aucun dommage    condition que la tension appliqu  e ne  d  passe pas la tension de sortie maximale du module d alimentation de plus de 20 Volts     La sortie  OUTPUT    tant d  sactiv  e  la charge reste connect  e    la phase de sortie du module  d alimentation   la tension de sortie est simplement d  finie sur z  ro  Ne pas appliquer aux bornes  du module d alimentation de tensions externes d  passant de plus de 20 V la tension de sortie  nominale  m  me lorsque la sortie est d  sactiv  e  car cela pourrait endommager l appareil     Protection contre les d  passements de temp  rature    20    Un capteur interne d  tecte les d  passements de temp  rature li  s    une obturation du flux d air   une d  faillance du ventilateur ou une autre d  faillance d un circuit  Un d  passement de  temp  rature d  sactive la sortie  l indicateur OUTPUT clignote et l   cran affiche le message   OtP triP  Une fois que la cause du d  passement de temp  rature a   t     limin  e et que  l instrument est refroidi  l indicateur de sortie s   teint  mais le message OtP triP reste pr  sent   Une pression sur la touche OUTPUT modifie l affichage et indique la tension et le courant  pr  d  finis  l indicateur SETTINGS s allume   mais la sortie reste d  sactiv  e   une deuxi  me  pression active normalement la sortie    En cas de pression sur la touche OUTPUT pendant que l instrument est toujours en d  passement  de temp  rature  l indicateur OUTPUT cli
26.  n  cessaire d utiliser une fiche secteur destin  e    un autre type de prise murale  employer un  cordon secteur correctement dimensionn   et homologu   en l   quipant de la fiche murale voulue  et d un connecteur IEC60320 C13 du c  t   de l appareil  Pour d  terminer l intensit   nominale  minimale du cordon en fonction de l   alimentation sur secteur pr  vue  consulter les  caract  ristiques de puissance nominale figurant sur le mat  riel ou dans le chapitre Sp  cifications     AVERTISSEMENT   CET APPAREIL DOIT ETRE RELI      LA TERRE     Toute interruption du conducteur de terre de la prise secteur    l int  rieur ou    l ext  rieur de  l appareil rendra ce dernier dangereux  Il est interdit d effectuer une coupure intentionnelle     Montage    Cet appareil convient a la fois a l   utilisation sur   tabli et au montage en baie  Un kit de montage  en baie pour une baie de 19 pouces est disponible aupr  s du Fabricant ou de ses agents a  l   tranger     Ventilation    Le module d alimentation est refroidi par un ventilateur intelligent multi vitesses qui favorise la  convection verticale  Veillez    ne pas obturer les prises d air sous l appareil ni les orifices de  ventilation sur le dessus  En cas de montage en rack  laisser un espace ad  quat au dessus et  au dessous de l   appareil et ou utiliser un bloc ventilateur pour un refroidissement forc       Connexions    Toutes les connexions sont effectu  es    partir du panneau avant    La charge devra   tre connect  e aux b
27.  que la limite de courant  de sortie du Master est maintenant r  duite de moiti       Les fonctions LOCK et VOLTAGE SPAN du Master op  rent exactement comme d  crit  pr  c  demment  Il est possible de basculer du mode Parallel au mode Tracking  et vice versa   alors que LOCK est toujours r  gl   sur le Master   les commandes Voltage et Current du Master  restent en LOCK  comme d  crit pr  c  demment  Toutefois  la limite de courant r  elle d  finie du  Master doublera encore  en passant du mode Tracking au mode Parallel   ou sera r  duite de  moiti    en passant du mode Parallel au mode Tracking   m  me si LOCK est d  fini  mais  l affichage du courant clignote pour vous avertir de ce changement     23    Param  tres du Slave conserv  s    Si V Span est activ   sur la sortie Slave en mode INDEPENDENT  il est d  sactiv   lorsque le mode  TRACKING ests  lectionn    mais r  activ    lorsque le mode INDEPENDENT est a nouveau  s  lectionn       Si Ratio     Tracking est activ   sur la sortie Slave en mode TRACKING  il est d  sactiv   lorsque  INDEPENDENT ou PARALLEL est s  lectionn    mais r  activ   lorsque le mode TRACKING est     nouveau s  lectionn       Commande Marche Arr  t de la sortie simultan  e    Les touches Both On   Both Off s ajoutent aux interrupteurs OUTPUT  individuels et permettent d activer ou de d  sactiver les deux sorties de  mani  re synchronis  e d une simple pression     Les touches Both On   Both Off fonctionnent dans les quatre modes de  configuration  
28.  seguridad del usuario durante su empleo     Este instrumento ha sido disefiado para ser utilizado en el interior en un ambiente de Grado 2 de  Poluci  n a temperaturas de entre 5  C y 40  C y una humedad relativa de entre el 20  y el 80    sin condensaci  n   De manera ocasional puede someterse a temperaturas de entre  10  C y   5  C sin que ello afecte a su seguridad  No hay que ponerlo en funcionamiento mientras haya  condensaci  n     El uso de este instrumento de forma no especificada por estas instrucciones puede afectar a su  seguridad  El instrumento no debe ser utilizado fuera de su rango de voltaje o de su gama  ambiental     ADVERTENCIA  ESTE INSTRUMENTO DEBE CONECTARSE A TIERRA    Cualquier interrupci  n del conductor a tierra dentro o fuera del instrumento implicaria que el  instrumento resultara peligroso  Esta prohibida cualquier interrupci  n intencionada de la  connexion a tierra  No debe utilizarse con un cable de tensi  n sin tierra     Mientras el instrumento est   conectado es posible que queden sin protecci  n elementos bajo  tension y la obertura de tapas o el retiro de piezas  salvo las accesibles por la mano  pueden  dejar expuestos a elementos bajo tensi  n  Si se tuviera que efectuar alguna operaci  n de ajuste   cambio  mantenimiento o reparaci  n es necesario desconectar el instrumento de todas las  fuentes de tensi  n  Los capacitores dentro del aparato pueden permanecer cargados aun  cuando las fuentes de tensi  n hayan sido desconectadas  pero 
29.  the Quad mode Dual instrument are  described together at the end of this chapter     Switching On and Power On Conditions    The POWER switch is located at the bottom left of the front panel  When the POWER switch is  turned on  I   the right hand meter briefly indicates the firmware revision before the display  shows Volts and Amps     At power on  the factory default setting is for the output to be off  All other settings will be the  same as they were at last power off     The dc output state at power on can be set to be    always off    or    same as  at last power off     The setting can be changed as follows  With the VIEW  key held down  press and hold down the       OUTPUT key  the display  will first show the present setting for 1 second  OP OFF if the factory  default is still selected  before flashing the new setting for 2 seconds    LASt Set inthis instance   After 2 seconds the new setting is shown  continuously in the display and the change is implemented  release the  OUTPUT and VIEW keys    Repeating the procedure will change the setting back to the previous state  Note that the power   on status of the two outputs of the dual supply need to be set individually        Output Control  Setting Up the Output    With the POWER switch on and the     OUTPUT off the output voltage and current limit can be  accurately preset using the VOLTAGE and CURRENT controls  the left hand meter shows the set  voltage  the right hand meter shows the set maximum current and the S
30.  the message turn oFF to prompt the user to turn the output off   To set new values for Vmin Or Vmax the V Span function must be off  cancelled     The lower voltage limit is defined by using the MAIN and FINE VOLTAGE controls to set exactly  the required value  the Vmin key is then held pressed until the left hand side  V  display stops  flashing and the right hand side  mA  display shows Set  The setting can be VIEWed at any  time by a short press   lt 1 second  of the Vmin key  The upper voltage limit is set and VIEWed in  exactly the same way using the VOLTAGE controls and the Vmax key    The limits can be set in any order and to any value within the output range of the instrument but  V Span can only be turned on with the ENABLE key if Vmax  gt   Vmin   0 1V   if this condition is not  met  the message Set Err is briefly displayed and the V Span function is not implemented   When V Span is enabled  the range of the MAIN VOLTAGE control is exactly Vmin to Vmax when    the FINE control is set at its mid point  marked on the panel witha e  The FINE control itself  can be usefully used to give an additional fine adjustment of  1   of the voltage span      Mode Control of the Quad Mode Dual    The four operating modes of the Quad Mode Dual are  described below  the mode is changed using the MODE  rotary switch  To prevent unintended voltages being     accidentally applied to the circuits connected to the outputs     MASTER  gt   changing modes will always cause both outputs t
31.  un lampeggio delle impostazioni     sbloccate    per 2 3 secondi  all   inizio pi   lentamente  poi pi   veloci   prima che la modifica venga implementata  l indicatore del LOCK si  spegner   una volta eseguita la modifica        Lasciando il tasto LOCK in qualunque momento durante il lampeggio del display  provocher    l annullamento dell   azione    Non    possibile cambiare il limite di corrente  vedi capitolo Impostazione dell   uscita   o i limiti  dell   ampiezza di tensione  vedi capitolo Ampiezza di tensione  con il LOCK attivato  in tal caso  verr   visualizzato brevemente il messaggio Unloc e l   indicatore del LOCK lampegger    Inoltre   se l uscita    attiva quando vengono tentate queste azioni  dapprima verr   visualizzato nel display  il messaggio turn oFF  con l indicatore d uscita lampeggiante   che sar   seguito dal  messaggio Unloc  con l indicatore del LOCK     lampeggiante      Utilizzo dell   ampiezza di tensione    La capacit   di VOLTAGE SPAN  ampiezza di tensione   V Span  permette all utente di ridefinire i  valori estremi dei controlli della VOLTAGE in modo che funzionino all   interno di una portata di  tensione specifica e pi   ristretta  Ci    non solo offre il vantaggio di proteggere contro le  applicazioni accidentali al carico di tensione al di fuori della portata  ma fornisce anche controllo  analogico ad alta risoluzione sulla portata di tensione specifica utilizzando la rotazione completa  a 300   dei controlli di tensione     V Span viene 
32. ENT  OUTPUT  LOCK  I messaggi visualizzati sul display a 7 segmenti sono  mostrati in caratteri diversi  ad esempio turn oFF  OtP trip  Le funzioni aggiuntive dello  strumento Dual Quad mode sono descritte tutte insieme alla fine di questo capitolo     Accensione e condizioni in fase di attivit      L interruttore di accensione  POWER  si trova in basso a sinistra sul pannello frontale  Quando     collocato su      il manometro a destra indica brevemente la revisione del firmware prima che il  display visualizzi i Volt e le Ampere di uscita     All   accensione  nelle preimpostazioni dalla fabbrica l   uscita dovrebbe trovarsi su spenta  Tutte le  altre configurazioni si ritroveranno nelle condizioni in cui si sono lasciate prima dell   ultima  disattivazione    Lo stato dell uscita DC all accensione pu   essere impostato per essere     sempre off o    come prima dell   ultima disattivazione     La configurazione pu    essere cambiata come segue  tenendo premuto il tasto VIEW  visualizza    tenere premuto il tasto OUTPUT     il display all   inizio mostrer   la  configurazione presente per 1 secondo  OP OFF se    ancora selezionata  quella di fabbrica  prima di cominciare a lampeggiare quella nuova per 2  secondi   LASt Set in questo caso   Dopo 2 secondi la nuova  impostazione rimane fissa sul display e la modifica viene realizzata  a questo  punto  rilasciare i tasti OUTPUT e VIEW     La ripetizione della procedura riporter   l impostazione allo stato precedente  Si noti ch
33. ETTINGS indicator is lit     When the output switch is switched on  the OUTPUT indicator lights  the left hand meter now  shows the actual voltage and the right hand meter the actual load current     The upper limit of the CURRENT control can be switched  between the maximum for this model and 500mA with  alternate presses of the 500mA RANGE key to give finer  current limit setting and measurement resolution  0 1mA up to  500mA   the indicator beside the key is lit when the 500mA  range is selected    To change the current limit range the output must be switched off  if the output is on the warning  message turn oFF is shown briefly in the display  the OUTPUT indicator flashes and the   range remains unchanged        Constant Voltage    The output voltage is adjusted using the main and fine VOLTAGE controls  the CURRENT control  sets the maximum current that can be supplied     Constant Current    If the load resistance is low enough such that  at the output voltage set  a current greater than the  current limit setting would flow  the power supply will automatically move into constant current  operation  The current output is adjusted by the CURRENT control and the VOLTAGE controls  set the maximum voltage that can be generated     The CC indicator lights to show constant current mode     Instantaneous Current Output    The current limit control can be set to limit the continuous output current to levels down to 1mA   0 1mA on 500mA range   However  in common with all precis
34. GE SPAN functions of the Master operate exactly as described previously   It is possible to switch from Parallel mode back to Tracking mode  and vice versa  with LOCK still  set on the Master  both the Voltage and Current controls of the Master stay in LOCK  as  described previously  However  the actual set current limit of the Master will still double  switching  from Tracking to Parallel  or halve  switching from Parallel to Tracking   even though LOCK is set   but the current display flashes as a warning that this has happened     Retained Slave Settings    If V Span is enabled on the Slave output in INDEPENDENT mode  it is disabled when TRACKING  mode is selected but re enabled when INDEPENDENT mode is re selected   If Ratio     Tracking is enabled on the Slave output in TRACKING mode  it is disabled when    INDEPENDENT or PARALLEL are selected but re enabled when TRACKING mode is re   selected     Simultaneous Output On Off Control       The Both On   Both Off keys are in addition to the individual OUTPUT switches  and permit both outputs to be turned on or off synchronously with a single key  press  The Both On   Both Off keys operate in all four configuration modes     Maintenance    The Manufacturers or their agents overseas will provide a repair service for any unit developing a  fault  Where owners wish to undertake their own maintenance work  this should only be done by  skilled personnel in conjunction with the service manual which may be purchased directly from  
35. Ger  t eine sehr geringe Ausgangsimpedanz besitzt  erh  ht sich diese zwangsweise  durch den Widerstand der angeschlossenen Kabel  Bei hohen Str  men ergibt sich hieraus ein  deutlicher Unterschied zwischen der angezeigten Quellspannung und der tats  chlichen  Lastspannung  zwei Anschlusskabel mit 20 mQ erzeugen z  B  bei einem Strom von 5 A einen  Spannungsabfall von 0 2 V     Dieses Problem l  sst sich zwar durch Verwendung kurzer  Anschlusskabel mit gro  em Querschnitt einschr  nken  es ist  aber besser  diesen Effekt mit Hilfe der Fernf  hlerfunktion  ganz zu umgehen  Dazu m  ssen die Fernf  hlerklemmen   Sense  an der Last anstelle der Spannungsquelle  angeschlossen werden  Schlie  en Sie die Kabel an die  Federklemmen des SENSE Anschlusses und direkt an der  Last an  Setzen Sie den Schalter LOCAL REMOTE auf  REMOTE    Um Instabilit  t und dynamisches Fehlverhalten zu vermeiden muss darauf geachtet werden  dass  eine gute Verbindung zwischen jedem Ausgangs  und Fernf  hlerkabel besteht  Dies wird erreicht   indem man entweder die Kabel miteinander verdrillt oder ein abgeschirmtes Koaxialkabel  verwendet  die Fernf  hlerleitung bildet hierbei den Innenleiter   Auch ein zum Lastanschluss  parallel geschalteter Elektrolytkondensator kann hilfreich sein                                                  Der Spannungsabfall des jeweiligen Ausgangskabels darf 0 5 Volt nicht   berschreiten   Setzen Sie den LOCAL REMOTE Schalter auf LOCAL zur  ck  wenn die Fernf  hlerfunktion nich
36. Il valore percentuale pu   essere mostrato in ogni momento premendo sia il tasto Vmin O il Vmax  dell uscita slave  Con uno dei due tasti premuto  il display Slave visualizza l impostazione  percentuale nella forma 90 0 Pent ei controlli della Tensione slave possono essere utilizzati  per impostare la percentuale di rapporto richiesto  La percentuale di rapporto pu   essere  impostata prima che il Rilevamento del rapporto sia attivato  indicatore ENABLE spento      Le funzioni LOCK e VOLTAGE SPAN Master funzionano esattamente come descritto in  precedenza  Tuttavia  con il Rilevamento del rapporto attivo  la i controlli della tensione Slave  possono ancora venire usati per regolare la percentuale del rapporto della tensione slave anche  se la tensione Master    bloccata     Vedi anche il paragrafo Impostazioni slave mantenute     Parallelo    L interruttore MODE    impostato su PARALLEL  parallelo   Lo strumento funziona in modalit    realmente parallela con tutte le alimentazioni disponibili dell uscita Master che pu   quindi fornire  fino a 6 amp  L uscita slave    disabilitata e i suoi display spenti     In modalit   Parallelo il valore del limite di corrente    raddoppiato per la stessa impostazione del  controllo di limite di Corrente  compreso il range 500mA  che diventa al massimo 1000mA  come  avvertimento  quando la modalit   Parallelo viene selezionata per prima  il display della corrente  lampeggia due volte prima di fissarsi sul nuovo limite  In modo simile  il di
37. Sensor erkennt   bertemperaturen aufgrund von blockierter Luftstr  mung   L  fterausfall oder einem Schaltungsfehler  Bei   bertemperatur wird der Ausgang abgeschaltet      die OUTPUT Anzeige blinkt und auf dem Display erscheint die Meldung OtP triP   Nachdem  die Ursache f  r die   bertemperatur behoben wurde und das Ger  t abgek  hlt ist  geht die  Ausgangsanzeige aus   die Meldung OtP triP wird jedoch weiterhin angezeigt  Wenn Sie die  Taste OUTPUT einmal dr  cken zeigt das Display die voreingestellten Werte f  r Strom und  Spannung an  die Anzeige SETTINGS leuchtet auf   der Ausgang bleibt jedoch abgeschaltet      erst beim zweiten Dr  cken der Taste wird der Ausgang normal eingeschaltet    Wird die Taste OUTPUT gedr  ckt  w  hrend das Ger  t   bertemperatur aufweist  Anzeige  OUTPUT blinkt   wird die Meldung OtP triP durch die Anzeige der voreingestellten Werte f  r  Strom und Spannung ersetzt  die Anzeige SETTINGS leuchtet auf   der Ausgang bleibt jedoch  abgeschaltet     bei jedem folgenden Dr  cken der Taste OUTPUT wird die Meldung OtP triP  kurz angezeigt  der Ausgang bleibt jedoch abgeschaltet  bis das   bertemperaturproblem beseitigt  ist     Einstellungen fur das Display    Die eingestellten Spannungs  und Strombegrenzungswerte  werden immer angezeigt  wenn der Ausgang abgeschaltet ist   k  nnen aber auch bei eingeschaltetem Ausgang eingesehen  werden  wenn Sie die Taste VIEW dr  cken     die SETTINGS  Anzeige leuchtet auf  w  hrend die VIEW Taste gedr  ckt ist   
38. Tracking au mode Independent alors que le LOCK est  toujours activ   sur le Master  Les param  tres Master  sortie de droite  restent    verrouill  s    mais  les param  tres de la sortie de gauche ne sont pas verrouill  s     Les touches Voltage Span du Slave ont une fonction diff  rente en mode Tracking  voir la section  suivante    Isolated Ratio     Tracking  D  finissez le MODE sur ISOLATED TRACKING     Le Ratio Tracking est activ   par une pression  sur la touche ENABLE dans la section  VOLTAGE SPAN du Slave  indicateur  ENABLE activ          L instrument fonctionne comme d  crit ci dessus pour le mode Tracking mais la tension du Slave  peut   tre d  finie sur un pourcentage  de 0      101    de la tension Master a l   aide des  commandes Slave Voltage  Le ratio est ensuite maintenu lorsque la tension du Master varie     Une nouvelle pression sur la touche ENABLE ram  ne le Slave au mode Tracking standard   indicateur ENABLE   teint     Le Ratio Tracking ne peut   tre activ   ou d  sactiv   que lorsque la sortie est d  sactiv  e  Si la  sortie est activ  e  l   cran affiche bri  vement le message turn oFF lorsque vous appuyez sur  ENABLE et le changement n est pas appliqu       Chaque fois que le mode Ratio Tracking est activ    l   cran Slave affiche temporairement Pent  on avant d afficher    nouveau la tension de sortie qui est maintenant d  finie     La valeur de pourcentage peut   tre affich  e    tout moment en appuyant sur la touche Vmin ou    Vmax de la sortie S
39. VOLTAGE SPAN  Vmin  VIEW  Vmax ENABLE OUTPUT    CdD  Do       Ju  HOLD TO SET     CANCEL             Ge           i    I I  i 300V pk i  max tok LOCAL REMOTE  POWER   SENSE  mt TT PA PL303QMD QUAD MODE DUAL POWER SUPPLY 30V 3A 6A        REMOTE ecc   SETTINGS   REMOTE ecc   SETTINGS  I wa an    A       nr wa an I  a JUDO JUDO JUDO 2000 m  I V V mA I      VII SETTINGS        METER 500mA     VILSETTINGS        METER 500mA i  VIEW LOCK AVERAGE RANGE VIEW AVERAGE RANGE  E  Coo Eo C jo Co c5 o  Jo EJo   LOCAL  HOLD TO CANCEL CANCEL CANCEL  LOCAL  HOLD TO CANCEL CANCEL CANCEL i      VOLTAGE     e CURRENT     VOLTAGE        CURRENT    I       MAIN O   me f   mn    e  i Vmin Vmax  100   Vmin jaa Vmax i  VOLTAGE SPAN            TRACKING  VOLTAGE SPAN  Vmin  VIEW  Vmax ENABLE OUTPUT Vmin_  VIEW  Vmax ENABLE OUTPUT  ES E Es   9 O E CDo    Jo UR  HOLD TO SET     CANCEL MODE     HOLD TO SET     CANCEL          ISOLATED TRACKING    OUTPUT    Y oO INDEPENDENT e__  _e Se O     L   l        30V  6A  gt   l  ti _ DO   LOCAL REMOTE   u pk   LOCAL REMOTE   11  max 10 TURN OUTPUTS OFF max 10    POWER ni SENSE WHEN CHANGING MODE SENSE  N    u DE SE ue             SE    Zus ss    Ez                                                                           Operation    In this manual front panel keys  controls and sockets are shown in capitals  e g  CURRENT   OUTPUT  LOCK  Messages displayed on the 7 segment LEDs are shown in a different type font   e g  turn oFF  OtP trip  The additional features of
40. a anterior  o los limites de amplitud de voltaje  vea el apartado Amplitud  de voltaje  con el indicador LOCK encendido tampoco es permitido  Si se intenta  el mensaje  Unloc es visualizado brevemente en la pantalla y el indicador LOCK tambi  n parpadea  Si la  salida tambi  n est   activada cuando se hacen estos intentos  el mensaje turn oFF es primero  visualizado en la pantalla  acompa  ado del parpadeo del indicador de salida  seguido del  mensaje Unloc  con el indicador LOCK parpadeando      Uso de la amplitud de voltaje    La caracteristica VOLTAGE SPAN  V Span   amplitud de voltaje  permite al usuario redefinir los  valores de tope final de los controles de VOLTAGE  de modo que   stos funcionen dentro de una  gama de voltaje mas estrecha especifica  Esto no s  lo ofrece la ventaja de proteger contra la  aplicaci  n accidental de la carga de voltajes fuera de la gama  sino que tambi  n ofrece un control  anal  gico de alta resoluci  n en la gama de voltaje especificada mediante la rotaci  n a 300   de  los controles de voltaje        La V Span se enciende o apaga mediante la tecla  ENABLE  activar   La lampara ENABLE se enciende  cuando se selecciona V Span  El ajuste en fabrida por    defecto es Vmin   3V  Vmax   5V       Debido a que al activar la V Span siempre se cambia el voltaje de salida  solamente podra  activarse o cancelarse con la salida desactivada  Si se intenta activar V Span con la salida  activada o cancelada  la pantalla visualizara brevemente el mensaj
41. able de salida no debe ser superior a 0 5 voltios   Vuelva a situarlo en LOCAL REMOTE si no usa detecci  n remota        49       Conexion en serie o paralelo con otras salidas    A    Las salidas de alimentaci  n son totalmente libres y se pueden utilizar en serie con otras  unidades de alimentaci  n para generar voltajes CC elevados de hasta 300 V CC     al    El voltaje maximo admisible entre cualquier terminal y la toma de tierra     es de 300 V CC     ADVERTENCIA  Estos voltajes son muy peligrosos y se debe tener mucho cuidado de proteger  los terminales de salida para este uso  Bajo ninguna circunstancia se deben tocar los terminales  de salida cuando se conecta la unidad para dicho uso  Todas las conexiones en los terminales  se deben hacer con la alimentaci  n desconectada en todas las unidades     Debe tenerse en cuenta que la unidad s  lo puede generar corriente y no puede absorberla  por  lo que las unidades no se pueden conectar en serie en antifase  La unidad se puede conectar en  paralelo con otras unidades para generar corrientes m  s grandes  Cuando se conecten varias  unidades en paralelo  el voltaje de salida ser   igual que el de la unidad con el mayor ajuste de  voltaje de salida  hasta que la corriente extra  da sobrepase su ajuste de l  mite de corriente  en  este punto la salida disminuir   hasta el siguiente ajuste m  s alto y as   sucesivamente  En el  modo de corriente constante  las unidades se pueden conectar en paralelo para ofrecer una  corriente
42. acceso o spento con il tasto ENABLE   attiva   L indicatore ENABLE    acceso quando     selezionato V Span  L impostazione della fabbrica       Vmin   3V  Vmax   5V             Poich   attivare il V Span cambia sempre la tensione d   uscita  esso pu   essere attivato o  annullato solo con la tensione inattiva  Se si tenta di attivarlo o annullarlo con la tensione in  funzione  il display mostrer   brevemente il messaggio turn oFF per avvisare l utente di  disattivarla     Per impostare nuovi valori per Vmin 0 Vmax le funzioni V Span devono essere disattivate   annullate     Il limite minimo di tensione viene definito utilizzando i controlli MAIN e FINE VOLTAGE  tensione  principale e fine    per impostare esattamente i valori desiderati  il tasto Vmin viene quindi tenuto  premuto fino a che il display di sinistra  V  smette di lampeggiare e quello di destra  MA  mostra  Set  Le impostazioni possono essere visualizzate sempre  con una breve pressione   lt 1  secondo  del tasto Vmin  Il limite massimo della tensione viene impostato e VIEWed  visualizzato   esattamente allo stesso modo  utilizzando i controlli di VOLTAGE e il tasto Vmax       limiti possono essere impostati nell ordine desiderato e con tutti i valori necessari all interno  della portata d   uscita dello strumento  ma il V Span pu   solo essere acceso con il tasto ENABLE    se Vmax 2  Vmin   0 1V   se non si verifica questa condizione  si visualizzer   brevemente il  messaggio Set Err e la funzione V Span non ver
43. alizados cuando la salida est   desactivada  pero tambi  n  pueden ser visualizados pulsando la tecla VIEW  visualizar   El  indicador SETTINGS estar   encendido mientras se la tecla VIEW  permanece pulsada        Ajustes del bloqueo    AI pulsar la tecla LOCK se bloquean digitalmente limite de corriente y el voltaje establecido  Los  ajustes son almacenados con una precisi  n superior a 1 digito  Ajustes subsiguientes de los  controles de VOLTAGE y CURRENT no tendran efecto alguno     Debido a que si se cancela LOCK  los ajustes de salida cambiar  n si se han desplazado las  posiciones de control de VOLTAGE y CURRENT  se generaran recordatorios de aviso antes de  que pueda cancelarse LOCK     Pulse y mantenga pulsada la tecla para cancelar LOCK     Si la OUTPUT est   apagada  estado seguro  el visualizador parpadear   dos veces los ajustes de     desbloqueada    antes de implementrse el cambio  la lampara LOCK se apaga     Si la salida todavia est   encendida  OP on  salida  encendida  parpadear   dos veces en el visualizador  seguido  del parpadeo de los nuevos ajustes    desbloqueados    durante  2 3 segundos  primero lentamente y luego con mas rapidez   antes de que el cambio sea finalmente implementado  la  lampara LOCK se apaga cuando se realiza el cambio        Soltando la tecla LOCK en cualquier momento mientras parpadea el visualizador se abortara la  cancelaci  n de LOCK Elintento de cambiar la gama de limite de corriente  vea el apartado  Configuraci  n de la salid
44. altung der Slave Einstellungen      Parallelbetrieb    Drehen Sie den Schalter MODE auf PARALLEL  Parallelbetrieb   Das Ger  t arbeitet nun  vollst  ndig parallel  sodass die gesamte Leistung von bis zu 6 Ampere am Master Ausgang zur  Verf  gung steht  Der Slave Ausgang ist deaktiviert und das entsprechende Display  ausgeschaltet     Im Parallel Betrieb verdoppelt sich der Strombegrenzungswert bei gleicher Einstellung des  Strombegrenzungsreglers  Dies gilt auch f  r den 500mA Bereich  der nun maximal 1000mA  abgeben kann  Zur Warnung blinkt die Stromanzeige beim Anw  hlen der Parallelfunktion zweimal  auf  bevor dann der neue Begrenzungswert angezeigt wird  Die Stromanzeige blinkt auch beim  Umschalten von Parallel  auf Tracking Betrieb zweimal auf  um darauf hinzuweisen  dass sich die  Master Strombegrenzung nun halbiert hat     33    Die Funktionen LOCK und VOLTAGE SPAN des Master Ausgangs arbeiten exakt wie oben  beschrieben  Sie k  nnen auch bei aktivierter LOCK Funktion am Master vom Parallel Betrieb  zuruck auf Tracking Betrieb  und umgekehrt  schalten  Die Spannungs  und Stromregler des  Master Ausgangs bleiben verriegelt  siehe oben   Jedoch verdoppelt  bei Umschalten von  Tracking auf Parallel  bzw  halbiert  bei Umschalten von Parallel auf Tracking  sich der aktuell  eingestellte Strombegrenzungswert des Master Ausgang  obwohl LOCK aktiviert ist  Dieser  Umstand wird durch das zweimalige Blinken des Displays angezeigt     Beibehaltung der Slave Einstellungen    Wen
45. and uniquely accept fixed shroud 4mm  plugs as well as standard plugs  bare wires and fork connectors    Table of Contents           Specification 2  EMC 5  Safety 6  Installation 7  Connections 8  Operation 9  Maintenance 14  Instructions en Francais 15  Bedienungsanleitung auf Deutsch 25  Istruzioni in Italiano 35    Instrucciones en Espa  ol 45    Specification    General specifications apply for the temperature range 5  C to 40  C  Accuracy specifications  apply for the temperature range 18  C to 28  C after 1 hour warm up with no load and calibration at  23  C  Typical specifications are determined by design and are not guaranteed     OUTPUTS    Voltage Current Ranges   PL 155  PL 303  PL 601  PL303QMD    OV to 15V 1mA to 5000mA  OV to 15V 0 1mA to 500mA  OV to 30V 1mA to 3000mA  OV to 30V 0 1mA to 500mA  OV to 60V 1mA to 1500mA  OV to 60V 0 1mA to 500mA    OV to 30V 1mA to 3000mA  OV to 30V 0 1mA to 500mA  each output    OV to 30V 2mA to 6000mA  OV to 30V 0 2mA to 1000mA  parallel mode      Note  Actual maxima for voltage and current are typically 1  greater than the figures given above     Voltage Setting   Current Setting     Configuration Selection    PL303QMD only     Voltage Span Control   V Span     Settings Lock   S Lock   Output Mode     Output Switch     Output Terminals   Transient Response     Ripple and Noise   20MHz bandwidth      Load Regulation     Line Regulation     Temperature Coefficient     Output Protection     OTP Protection     By coarse and fine 
46. ase screws are correctly refitted and tightened     b  In the event of part replacement becoming necessary  only use components of an identical  type  see the Service Manual     Safety    This instrument is a Safety Class   instrument according to IEC classification and has been  designed to meet the requirements of EN61010 1  Safety Requirements for Electrical Equipment  for Measurement  Control and Laboratory Use   It is an Installation Category Il instrument  intended for operation from a normal single phase supply     This instrument has been tested in accordance with EN61010 1 and has been supplied in a safe  condition  This instruction manual contains some information and warnings which have to be  followed by the user to ensure safe operation and to retain the instrument in a safe condition     This instrument has been designed for indoor use in a Pollution Degree 2 environment in the  temperature range 5  C to 40  C  20    80  RH  non condensing   It may occasionally be  subjected to temperatures between  5  C and  10  C without degradation of its safety  Do not  operate while condensation is present     Use of this instrument in a manner not specified by these instructions may impair the safety  protection provided  Do not operate the instrument outside its rated supply voltages or  environmental range    WARNING  THIS INSTRUMENT MUST BE EARTHED    Any interruption of the mains earth conductor inside or outside the instrument will make the  instrument dangerous  Inte
47. ating and either can be connected to ground     Remote sense connections to the load  if required  are made from the positive     and  negative       SENSE terminals  Switch the LOCAL REMOTE switch to REMOTE when remote  sensing is required  Switch back to LOCAL when remote sensing is not in use     The terminal marked L is connected to the chassis and safety earth ground                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                  Cc    pie       Ze             PL303 POWER SUPPLY 30V3A     Di LI    REMOTE ecc   SETTINGS  i      gt   e 71        i mA    VITSETTINGS        METER 500mA    VIEW LOCK AVERAGE RANGE  i C  Coo Eo Coo    i  LOCAL  HOLD TO CANCEL CANCEL CANCEL        VOLTAGE     e CURRENT  I A AD    Il I  FRONT PANEL VIEW m CRE     a     ALA   Single and Dual  Vmin Vmax    
48. be  previamente  Sin embargo  con el Seguimiento de proporci  n activado  los controles de voltaje  de la Esclava todavia pueden ser usados para ajustar el porcentaje proporcional del voltaje de la  Esclava incluso si el voltaje de la Maestra esta bloqueado     Vea tambi  n el parrafo Ajustes de Esclava retenidos     Paralelo    El conmutador de MODE se ajusta en PARALLEL  paralelo   El instrumento funciona en el modo  paralelo verdadero con toda la potencia disponible de la salida Maestra que puede suministrar  hasta 6 amperios  La salida Esclava es desactivada y sus visualizadores son apagados     En modo Paralelo  el valor del limite de corriente es doblado para el mismo ajuste del control de  limite de corriente  incluido el rango de 500mA que se dobla a 1000mA maximo  a modo de  aviso  cuando se selecciona por primera vez el modo Paralelo  el visualizador de corriente  parpadea dos veces antes de visualizar de manera uniforme el nuevo limite  De manera similar   el visualizador de corriente parpadea dos veces cuando el modo se cambia de Paralelo a  Seguimiento  como aviso de que el limite de corriente de salida Maestra sed ha reducido ahora a  la mitad     53    Las funciones LOCK y VOLTAGE SPAN de la Maestra funcionan exactamente como se describe  previamente  Es posible conmutar de modo Paralelo de nuevo al modo de Seguimiento  y a la  inversa  con LOCK todavia ajustado en la Maestra  los controles de Voltaje y Corriente de la  Maestra permanecen ambos en LOCK  como se
49. c appara  t dans l   cran Slave et la fonction LOCK doit   tre  d  sactiv  e  en mode Independent  avant que les modes Tracking puissent   tre utilis  s     Voir aussi le paragraphe Param  tres Slave conserv  s     Isolated Tracking    22    D  finissez le MODE sur ISOLATED TRACKING  Les deux sorties restent isol  es   lectriquement   mais les contr  les de Voltage de la sortie Master pr  sentent une tension identique sur la sortie  Slave  Les commandes Current du Slave restent ind  pendant  notamment la plage 500 mA et les  fonctions Meter Average     Lisolation   lectrique permet aux deux sorties d     tre connect  s afin de fournir  par exemple  les  tensions de sortie de polarit   oppos  e ou des tensions identiques connect  es    diff  rentes  r  f  rences du syst  me  par ex  la prise de terre num  rique et la prise de terre analogique      Les fonctions LOCK et VOLTAGE SPAN du Master fonctionnent exactement comme d  crit  pr  c  demment et  comme la tension de sortie du Slave suit celle du Master  elles contr  lent    galement la fonction de sortie Slave  Notez que seule la tension de sortie du Slave est  verrouill  e lorsque le LOCK Master est utilis     les commandes de courant du Slave  y compris  les fonctions 500mA Range et Meter Average  restent ind  pendantes     La touche LOCK de la sortie Slave est ignor  e et si on l utilise  elle fait appara  tre temporairement  le message In trac sur l   cran Slave    titre de rappel     Il est possible de basculer du mode 
50. condensador esta conectado a la salida para  mantener la estabilidad y una respuesta transitoria correcta  Este condensador se carga en el  voltaje de salida  y la carga de la salida generar   un impulso de corriente cuando el condensador  se descarga  lo cual es independiente del ajuste del limite de corriente     Promediado del contador de corriente    Para reducir la inestabilidad de medici  n con corrientes de carga  r  pidamente variables podr   seleccionarse una constante de tiempo  de 2 segundos pulsando la tecla METER AVERAGE  promediado de  contador   el indicador adyacente a la tecla se enciende cuando se  selecciona promediado de contador  Pulse la tecla de nuevo para  CANCEL  cancelar  el promediado de contador y retornar a la  constante de tiempo de 20ms        Eficacia    El suministro de corriente minimiza la disipaci  n mediante el uso de prerregulaci  n electr  nica  para mantener un voltaje general reducido a los reguladores de salida  Adem  s  para optimizar  el funcionamiento a los extremos de voltaje de entrada de l  nea y potencia de salida  la relaci  n  del secundario del transformador se cambia ingeniosamente por medio de un rel    Se usa  hist  resis en el punto del umbral para prevenir una conmutaci  n innecesaria cuando la salida se  establece en aproximadamente aquel nivel  Aparte de escuchar un    clic      el usuario no se  percatar   de que el rel   se ha activado  la salida no experimentar   perturbaciones     Conexi  n a la Carga    La carga 
51. controls    By single logarithmic control    Independent  True parallel  Isolated Tracking  amp  Isolated Ratio Tracking  modes via front panel rotary switch    The voltage adjustment range can be controlled by digital setting of the  end stop values of the coarse voltage control to any desired values     The range for Vmax is 0 1V to 15V 30V 60V depending on model   The range for Vmin is 0 to  Vmax     0 1V     Voltage and current settings can be locked by a single button press   Lock accuracy is equal to meter accuracy  see Meter Specification   Constant voltage or constant current with automatic cross over    CC indicator lit in constant current mode     Electronic  non isolating   Preset voltage and current limit displayed when Output is off   Output rise time with no load  lt 15ms   Universal 4mm safety binding posts on 19mm  0 75     spacing for Output   screwless terminals for Sense    lt 50us to within 50mV of setting for a 90  load change   Normal mode voltage   lt 0 4mVrms and 2mVp p  Normal mode current   lt 0 2mArms   lt 40uArms on 500mA range   Common mode current   lt 5uArms  For any load change  measured at the output terminals  using  remote sense   Voltage  lt 0 01    2mV   Add typically 2 5mV for a 0 5V drop in the positive output lead   Specification applies for sense lead resistance  lt 0 5Q   Current typically 0 01    500uA   Voltage  lt 0 01    2mV for 10  line change   Current  lt 0 01    250pA for 10  line change   Voltage  typically  lt  50ppm   0 5mV
52. de Promediado de Medidor y  Rango de 500mA      El aislamiento el  ctrico permite conectar las dos salidas para proveer  por ejemplo  voltajes de  seguimiento de polaridad opuesta o voltajes id  nticos conectados a referencias de sistema  diferentes  e g  tierra digital y tierra anal  gica      Las funciones LOCK y VOLTAGE SPAN en la salida Maestra funcionan exactamente como se  describe previamente y  debido al voltaje de salida de la Esclava sigue la Maestra  tambi  n  controlan el voltaje de la salida Esclava  Tenga en cuenta que solamente el voltaje de salida de la  Esclava es    bloqueado    cuando se usa LOCK de Maestra  los controles de corriente de la    Esclava  incluidas las funciones de Promediado de Medidor y Gama de 500mA   permanecen  independientes    La tecla LOCK en la salida Esclava es ignorada y al pulsarla hace que el mensaje In trac  sea mostrado momentaneamente en el visualizador de la Esclava como un recordatorio    Es posible conmutar de modo Seguimiento de nuevo a modo Independiente con LOCK todavia  ajustado en Maestra  Los ajustes de    Maestra     salida derecha  permanecen    bloqueados    pero  los ajustes de la salida izquierda no son bloqueados    Las teclas de Amplitud de voltaje de la Esclava tienen una funci  n diferente en el modo de  Seguimiento  vea la secci  n siguiente     Seguimiento     de proporci  n de aislamiento  Ajuste el conmutador MODE en ISOLATED TRACKING        El seguimiento de proporci  n se activa  pulsando la tecla ENABLE
53. de funcionamiento del doble de modo  cuadrete se describen abajo  el modo se cambia usando el  conmutador rotatorio de MODE  modo   Para prevenir que sean  aplicados fortuitamente voltajes no intencionados a los circuitos  conectados a las salidas  los modos cambiantes siempre har  n  desconectar las salidas     Sin embargo  no es posible garantizar que nunca se producir  n transientes no deseadas al  encender el modo y por consiguiente se recomienda que ambas salidas sean siempre  apagadas antes de realizar cualquier cambio     Independiente    Ajuste el conmutador de MODE a INDEPENDENT  independiente   Las dos salidas son  completamente independiente y est  n aisladas el  ctricamente  cada una de ellas puede ser  ajustada como se describe en la secci  n precedente Control de salida    No es posible conmutar de modo Independiente a Seguimiento con LOCK ajustado en la salida  esclava  El mensaje Un loc se muestra en el visualizador de esclava y deber   apagarse  primero LOCK  en modo Independiente  antes de que puedan usarse los modos de Seguimiento     Vea tambi  n el p  rrafo sobre Ajustes de esclava retenidos     Seguimiento aislado    52    Ajuste el conmutador de MODE en ISOLATED TRACKING  seguimiento aislado   Las dos  salidas permanecen el  ctricamente aisladas pero los controles de Voltaje de la salida Maestra  son ajustados a un voltaje id  ntico en la salida Esclava  Los controles de Corriente de la salida  Esclava permanecen independientes  incluidas las funciones 
54. debe conectarse a los terminales OUTPUT positivo  rojo  y negativo  negro  Ambas son  totalmente flotantes y cualquiera de ellas puede ser conectada a tierra     Detecci  n remota    La unidad tiene una impedancia de salida sumamente baja  pero   sta es inevitablemente  incrementada por la resistencia de los cables de conexi  n  En corrientes elevadas  esto puede  ocasionar diferencias significativas entre el voltaje primario indicado y el voltaje real de carga   por ejemplo  dos cables de conexi  n de 20mQ disminuir  n 0 2V a 5 amperios      Este problema se puede minimizar utilizando cables de  conexi  n cortos y gruesos  aunque cuando sea necesario  se puede solucionar completamente utilizando la  capacidad de detecci  n remota                                                                 Esto requiere conectar los terminales de detecci  n a la  salida en la carga en lugar de en la fuente  Introduzca los  cables en los terminales de muelle SENSE y con  ctelos  directamente en la carga  Sit  e el interruptor  LOCAL REMOTE en REMOTE     Para evitar problemas de respuesta transitoria e inestabilidad  deber   asegurarse que haya un  buen acoplamiento entre cada cable de salida y detecci  n  Esto puede hacerse retorciendo los  cables conjuntamente o usando cables coaxialmente apantallados  detecci  n a trav  s del  interior  Tambi  n puede ser ventajoso instalar un condensador electrol  tico directamente en el  punto de conexi  n de carga        La ca  da de voltaje en cada c
55. der Betriebsart  immer beide Ausgange abgeschaltet                  WHEN CHANGING MODE      Ungewollte Spannungsspitzen k  nnen jedoch nie ganz ausgeschlossen werden  sodass vor dem  Wechsel der Betriebsart immer beide Ausgange abgeschaltet werden m  ssen     Unabhangig    Drehen Sie den MODE Schalter auf INDEPENDENT  Unabh  ngig   Beide Ausg  nge arbeiten  nun v  llig unabh  ngig voneinander und sind elektrisch voneinander isoliert  Sie k  nnen wie oben  im Abschnitt    Ausgangsregelung    beschrieben eingestellt werden    Ein Umschalten vom unabh  ngigen Betrieb auf Tracking Betrieb ist nicht m  glich  wenn die  LOCK Funktion des Slave Ausgangs aktiviert ist  In diesem Fall erscheint die Meldung Un loc  im Slave Display  Die Funktion LOCK muss zuerst deaktiviert werden  im unabh  ngingen  Betrieb  bevor ein Umschalten auf Tracking Betrieb m  glich ist    Siehe hierzu auch den Abschnitt zur    Beibehaltung der Slave Einstellungen        Isolierte Synchronregelung    32    Drehen Sie den MODE Schalter auf ISOLATED TRACKING  Isolierte Synchronregelung    Beide  Ausg  nge bleiben elektrisch voneinander isoliert  allerdings wird nun durch die Spannungsregler  des Master Ausgangs eine identische Spannung am Slave Ausgang erzeugt  Die Stromregler des  Slave Ausgangs lassen sich weiter unabh  ngig bedienen  einschl  des 500mA Bereichs und der  Mittelungsfunktionen      Durch die elektrische Entkopplung k  nnen die beiden Ausg  nge beispielsweise Tracking   Spannungen mit entgegenge
56. e accompanying documentation  incorrect operation  may damage the instrument     Earth  ground  terminal   mains supply OFF     mains supply ON     alternating current  ac       2  o   gt     direct current  dc     Installation    Mains Operating Voltage    Check that the instrument operating voltage marked on the rear panel is suitable for the local supply   Should it be necessary to change the operating voltage  proceed as follows     1  Ensure that the instrument is disconnected from the AC supply     2  Remove the plastic push rivets at each side edge of the top cover  Use the blade of a small  screwdriver to first ease out the rivet head and then fully remove the rivet body  Remove the two  rear panel screws securing the top cover  slide the cover back and lift off     3  Change the transformer connections  two transformers on the dual  following the diagrams     230V Operation 115V Operation       BLUE BROWN BLUE BROWN    4  Re assemble in the reverse order  To comply with safety standard requirements the operating  voltage marked on the rear panel must be changed to clearly show the new voltage setting     Fuse  The AC fuse is located in the fuse drawer in the lower part of the IEC inlet connector  To change the  fuse remove the line cord and open the fuse drawer with a suitable tool   The correct fuse type is 20 x 5mm 250V HBC time lag with the following rating   230V 115V  Single  1 6A  T  3 15A  T   Dual  3 15A  T  6 3A  T   Make sure that only fuses with the requir
57. e il flusso di  corrente si interromper    se l   uscita viene attivata sul misuratore di tensione si legger   quella  applicata  Non risulter   alcun danno fornendo una tensione che non superi quella massima  consentita dall   uscita dell   alimentatore per pi   di 20 V     Con l OUTPUT disattivata  il carico rimane connesso allo stadio d   uscita dell   alimentatore  la  tensione d uscita    semplicemente impostata su zero  Ai terminali dell alimentatore non applicare  tensioni esterne che superino di 20V la tensione d uscita stabilita  anche con l uscita disattivata   per evitare danni     Protezione da sovratemperatura    Un sensore interno individuer   la sovratemperatura causata da un blocco del flusso dell   aria  da  un guasto della ventola o altri problemi del circuito  La sovratemperatura far   disattivare l   uscita   l indicatore OUTPUT comincer   a lampeggiare e il display mostrer   il messaggio OtP triP    Una volta rimossa la causa e raffreddato il dispositivo  l indicatore d   uscita si spegnera  ma il  messaggio OtP triP rester   visualizzato  Premendo il tasto OUTPUT una volta  il display  passer   a mostrare la tensione e la corrente preimpostate  l indicatore delle SETTINGS   impostazioni      si illuminer    ma l   uscita rimarr   inattiva  premendolo una seconda volta l uscita  di riattiver   normalmente    Se il tasto OUTPUT viene premuto mentre lo strumento    ancora in sovratemperatura   l indicatore OUTPUT     lampeggia  il messaggio OtP triP viene s
58. e l instrument ouvert est branch      une source d alimentation  mais si c est absolument  n  cessaire  seul un technicien comp  tent au courant des risques encourus doit effectuer ce  genre de travaux    S il est   vident que l instrument est d  fectueux  qu il a   t   soumis    des d  g  ts m  caniques      une humidit   excessive ou    une corrosion chimique  la protection de s  curit   sera amoindrie et il  faut retirer l appareil  afin qu il ne soit pas utilis    et le renvoyer en vue de v  rifications et de  r  parations    Uniquement remplacer les fusibles par des fusibles d intensit   nominale requise et de type  sp  cifi    Il est interdit d utiliser des fusibles bricol  s et de court circuiter des porte fusibles    Eviter de mouiller l instrument lors de son nettoyage    Les symboles suivants se trouvent sur l instrument  ainsi que dans ce manuel     A ATTENTION   se r  f  rer a la documentation   Borne de terre  masse   ci jointe  toute utilisation incorrecte risque    d endommager l appareil     O alimentation secteur OFF    teinte  l alimentation secteur ON  allum  e     ANZ courant alternatif  c a       courant continu  c c      15    Installation    Tension d   alimentation sur secteur    V  rifier que la tension d   alimentation a l arri  re de l appareil correspond    celle du secteur  S il  s av  re n  cessaire de changer de tension d   alimentation  proc  der comme suit      1  Assurez vous que l instrument est d  connect   du secteur     2  Retirez les riv
59. e lo stato  attivo delle due uscite dell   alimentazione duale deve essere impostato singolarmente        Controllo uscita  Impostazione dell   uscita        Con l alimentazione  power  attivata e il   OUTPUT spento  la tensione d uscita e il limite di  corrente possono essere accuratamente preimpostati utilizzando i controlli VOLTAGE  tensione    e CURRENT  corrente   il misuratore a sinistra mostra la tensione impostata  quello a sinistra  il  valore massimo di corrente e l indicatore delle SETTINGS  impostazioni     acceso    Quando lo switch d uscita    attivato  l indicatore OUTPUT si accende  il misuratore a sinistra ora  visualizza la tensione corrente e quello a destra la tensione di carico    Il limite pi   alto del controllo di CURRENT pu   essere posizionato tra  quello massimo per questo modello e 500mA  con pressioni alternate  del tasto 500mA RANGE  portata 500mA   che offre la possibilit   di     impostare i limiti di corrente e la risoluzione di misurazione  da 0 1mA    fino a 500mA  in maniera pi   precisa  l indicatore accanto al tasto        acceso quando    selezionata la portata 500mA    Per modificare la portata del limite di corrente  l uscita deve essere disattivata  se attiva  nel   display appare brevemente il messaggio di avvertimento turn oFF  l indicatore OUTPUT  lampeggia e la portata rimane immutata     Tensione costante    La tensione d uscita    regolata utilizzando i controlli VOLTAGE principale e fine  il controllo  CURRENT imposta la corren
60. e stata  compromessa e lo strumento deve essere ritirato dall uso e rimandato indietro per le prove e le  riparazioni del caso     Assicurarsi di usare solo fusibili della portata giusta e del tipo corretto durante eventuali  sostituzioni  Sono proibiti sia l   uso di fusibili improvvisati che il corto circuito deliberato dei  portafusibili  Evitare di bagnare lo strumento quando lo si pulisce     Sullo strumento e in questo manuale si fa uso dei seguenti simboli     Attenzione   vedere i documenti allegati  L uso errato  pu   danneggiare lo strumento     Terminale di terra  alimentazione OFF  spenta   alimentazione ON  accesa     Corrente Alternata    I    oD    Corrente Continua    35    Installazione    Tensione di esercizio    Controllare che la tensione di esercizio dello strumento segnalata sul pannello posteriore sia   conforme alla tensione di alimentazione locale  Se fosse necessario modificarla  procedere come   segue    1  Verificare che lo strumento sia staccato dall alimentazione elettrica AC    2  Rimuovere i rivetti a pressione di plastica alle estremit   della copertura superiore  Inserire la  punta di un piccolo cacciavite per estrarre la testa del rivetto  quindi rimuoverlo    completamente  Rimuovere le due viti del pannello posteriore che fissano la copertura  superiore  quindi farla scivolare indietro e sfilarla     3  Cambiare le connessioni del trasformatore  due trasformatori sul duale  secondo il  diagramma qui sotto     230V Operation 115V Operation 
61. e turn oFF para indicar al  usuario que proceda a desactivar la salida     Para ajustar nuevos valores para Vmin 0 Vmax  la funci  n V Span debe estar apagada   cancelada      51    El limite de voltaje inferior se define usando los controles MAIN y FINE VOLTAGE  voltaje    principal y preciso  para establecer el valor exacto requerido  Seguidamente la tecla Vmin se  mantiene pulsada hasta que en parpadeo en la pantalla  V  se detiene y en la pantalla  mA   derecha se visualiza Set  El ajuste podra ser visualizado  VIEW  en cualquier momento    pulsando brevemente   lt 1 segundo  la tecla Vmin   El l  mite del voltaje superior se establece y  visualiza exactamente del mismo modo usando los controles de VOLTAGE y pulsando la tecla  Vmin     Estos l  mites pueden ajustarse en cualquier orden y en cualquier valor dentro de la gama de  salidas del instrumento  pero la V Span s  lo puede activarse pulsando la tecla ENABLE si Vmax     Vmin   0 1V   Si no se satisface este requisito  el mensaje Set Err es visualizado brevemente  y la funci  n V Span no es implementada    Cuando se activa la V Span  la gama del control de MAIN VOLTAGE  voltaje principal  es  exactamente de Vmin a Vmax cuando el control FINE  preciso  est   ajustado en su punto    intermedio  marcado en el panel con e   El propio control FINE puede ser eficazmente usado  para aportar un ajuste preciso adicional de  1   de la amplitud de voltaje      Control de modo del doble del modo cu  druple       Los cuatro modos 
62. ed current rating and of the specified type are used for  replacement  The use of makeshift fuses and the short circuiting of fuseholders are prohibited   Mains Lead  Connect the instrument to the AC supply using the mains lead provided  Should a mains plug be  required for a different mains outlet socket  a suitably rated and approved mains lead set should be  used which is fitted with the required wall plug and an IEC60320 C13 connector for the instrument  end  To determine the minimum current rating of the lead set for the intended AC supply  refer to the  power rating information on the equipment or in the Specification   WARNING  THIS INSTRUMENT MUST BE EARTHED   Any interruption of the mains earth conductor inside or outside the instrument will make the instrument  dangerous  Intentional interruption is prohibited   Mounting  This instrument is suitable both for bench use and rack mounting  A rack kit for mounting in a 19    rack  is available from the Manufacturers or their overseas agents   Ventilation    The power supply is cooled by an intelligent multi speed fan which aids vertical convection  Take care  not to restrict the air inlets underneath or the vents on the top  When rack mounted allow adequate  space above and below the instrument and or use a fan tray for forced cooling        Connections    All connections are made from the front panel     The load should be connected to the positive  red  and negative  black  terminals marked  OUTPUT  Both are fully flo
63. egler auf einen Prozentsatz  0  bis 101   der Master Spannung  eingestellt werden  Dieses Verh  ltnis wird bei einer Ver  nderung der Master Spannung  aufrechterhalten     Durch erneutes Dr  cken auf ENABLE wird der Slave Ausgang wieder in den normalen Tracking   Betrieb zur  ckversetzt  ENABLE Leuchte aus      Die Aktivierung Deaktivierung der prozentualen Synchronregelung ist nur bei ausgeschaltetem  Ausgang m  glich  Ist der Ausgang eingeschaltet  so erscheint beim Dr  cken der Taste ENABLE  kurz die Meldung turn oFF und es erfolgt keine   nderung     Bei aktivierter prozentualer Synchronregelung erscheint kurz die Meldung Pent on auf dem  Slave Display  bevor wieder die aktuell eingestellte Ausgangsspannung angezeigt wird     Sie k  nnen den Prozentwert jederzeit darstellen  indem Sie die Taste Vmin oder Vmax am Slave   Ausgang dr  cken  Bei Dr  cken und Halten dieser Tasten erscheint die Prozenteinstellung in der  Form 90 0 Pent und der Verh  ltniswert kann mit den Slave Spannungsreglern eingestellt  werden  Der Prozentwert kann vor Aktivierung der prozentualen Synchronregelung eingestellt  werden  ENABLE Leuchte aus      Die Funktionen LOCK und VOLTAGE SPAN des Master Ausgangs arbeiten exakt wie oben  beschrieben  Allerdings kann bei aktivierter prozentualer Synchronregelung der Verh  ltniswert f  r  die Slave Spannung mit den Slave Spannungsreglern weiterhin eingestellt werden  obwohl die  Master Spannung verriegelt ist     Siehe hierzu auch den Abschnitt zur    Beibeh
64. el extranjero     Limpieza    54    Si la unidad de suministro de fuerza necesita ser limpiada  utilizar un pafio brevemente  humedecido en agua o en un detergente suave  La ventana de visualizaci  n debe lustrarse con  un pafio suave y seco     ADVERTENCIA  PARA EVITAR CHOQUES ELECTRICOS O DANAR A LA UNIDAD DE  SUMINISTRO DE FUERZA  NUNCA DEJE ENTRAR AGUA AL ENVASE  PARA EVITAR QUE  EL ENVASE O LA VENTANA DE VISUALIZACION SEAN DANADOS  NUNCA LIMPIE CON  SOLVENTES        Thurlby Thandar Instruments Ltd  Glebe Road  Huntingdon  Cambridgeshire PE29 7DR  England  Telephone   44  0 1480 412451 Fax   44  0 1480 450409  International website  www tti test com UK website  www tti co uk  e mail  sales tti test com    Book Part No  48511 1050 Issue 2    
65. emmen  Kondensatoren in der Stromversorgung k  nnen auch noch nach Abschalten  s  mtlicher Stromversorgung Spannung f  hren  sie entladen sich jedoch innerhalb von etwa einer  Minute nach Spannungsabschaltung     Jegliche Nachstellung  Wartung und Reparatur am ge  ffneten  unter Spannung stehenden Ger  t   ist nach M  glichkeit zu vermeiden  Falls unvermeidlich  sollten solche Arbeiten nur von  qualifiziertem Personal ausgef  hrt werden  das sich der Gefahren bewusst ist     Ist das Ger  t eindeutig fehlerbehaftet  bzw  wurde es mechanisch besch  digt    berm    iger  Feuchtigkeit oder chemischer Korrosion ausgesetzt  so k  nnen die Schutzeinrichtungen  beeintr  chtigt sein  weshalb das Ger  t aus dem Verkehr zur  ckgezogen und zur   berpr  fung  und Reparatur eingesandt werden sollte     Sicherstellen  da   nur Sicherungen der vorgeschriebenen Stromst  rke und des vorgesehenen  Typs als Ersatz verwendet werden  Provisorische    Sicherungen    und der Kurzschluss von  Sicherungshaltern ist verboten  Beim Reinigen darauf achten  dass das Ger  t nicht nass wird     Am Ger  t werden folgende Symbole verwendet     Vorsicht  Bitte beachten Sie die beigef  gten Unterlagen   Falsche Bedienung kann Schaden am Ger  t verursachen     Erdungsklemme  Netz OFF  aus     Netz ON  ein     Wechselstrom      e  OF D    Gleichstrom    25    Installation    Netzbetriebsspannung    Pr  fen Sie  dass die an der Ger  ter  ckplatte angezeigte Netzspannung Ihrem lokalen Netz  entspricht  Sollte es er
66. en    und das   berbr  cken von  Sicherungshaltern sind verboten     Netzkabel    26    SchlieRen Sie das Gerat unter Verwendung des mitgelieferten Netzkabels an die  Wechselspannungsversorgung an  Falls ein Netzstecker f  r eine unterschiedliche Netzsteckdose  erforderlich ist  muss ein geeigneter und zugelassener Netzkabelsatz verwendet werden  der mit  dem geeigneten Wandstecker und einem IEC60320 C13 Stecker fur das Gerateende versehen  ist  Zur Bestimmung der Mindest Nennstromstarke des Kabelsatzes fur die beabsichtigte  Wechselspannungsversorgung sind die Informationen zu Leistungswerten auf dem Gerat bzw  in  seiner Spezifikation hinzuzuziehen     ACHTUNG  DIESES GERAT MUSS GEERDET SEIN     Jegliche Unterbrechung der Netzerde  ob im Innern oder au  erhalb des Ger  ts  macht das Ger  t  zur Gefahrenquelle  Eine absichtliche Unterbrechung ist verboten     Befestigung    Dieses Ger  t kann auf einer Arbeitsplatte oder in einem Gestell befestigt werden  Ein Rack   Montagesatz f  r ein 19    Rack ist vom Hersteller oder einem Fachh  ndler erh  ltlich     Beluftung    Das Ger  t wird mittels intelligenter Gebl  se mit stufenweiser Drehzahlregelung gek  hlt  um so  die Vertikalkonvektion zu unterst  tzen  Es muss sichergestellt werden  dass die Luftein  und    ausl  sse auf der Unter  und Oberseite des Ger  ts nicht blockiert werden  Bei Ger  ten  die im  Rack montiert sind  muss gen  gend Raum um das Ger  t gelassen werden und oder eine  Zwangsk  hlung mittels eines zus  tzl
67. ensemble ou utiliser des cables    protection coaxiale  d  tection par le fil interne   Un  condensateur   lectrolytique plac   directement sur le point de connexion de la charge peut    galement s   averer avantageux   La chute de tension dans chaque fil de sortie ne doit pas d  passer 0 5 Volts   Replacez le commutateur LOCAL REMOTE sur LOCAL lorsque la d  tection    distance n est pas  utilis  e                                                               19    Connexion en S  rie ou en Parall  le avec d   Autres Sorties    A    Les sorties du g  n  rateur sont enti  rement flottantes et peuvent   tre utilis  es en s  rie avec  d autres g  n  rateurs pour produire des tensions hautes CC allant jusqu   a 300 V CC     L    La tension maximale admise entre toute borne et la terre     est de 300 VCC    AVERTISSEMENT   De telles tensions sont excessivement dangereuses et un grand soin devra    tre apport      la protection des bornes pour une telle utilisation  En aucun cas on ne devra  toucher les bornes de sortie lorsque le g  n  rateur est allum   pour une telle utilisation  Tous les  branchements aux bornes doivent   tre   tablis avec tous les appareils hors tension     Il convient de noter que le g  n  rateur ne peut que produire du courant et non en absorber  ainsi  les g  n  rateurs ne peuvent   tre connect  s en s  rie en anti phase     L appareil peut   tre connect   en parall  le avec d autres pour produire des courants plus forts   Lorsque plusieurs appareils sont c
68. essed while the instrument is still over temperature  OUTPUT indicator is  flashing   the message OtP triP is replaced by the preset voltage and current  the  SETTINGS indicator will be lit  but the output will remain off  each subsequent press of the  OUTPUT key causes the OtP triP message to be displayed briefly but the output will remain  off until the over temperature condition ends     View Settings    The set voltage and current limit are always shown when  the output is off but can also be viewed when the output is    on by pressing the VIEW key  the SETTINGS indicator is lit  whilst the VIEW key is pressed        Lock Settings    Pressing the LOCK key digitally locks the set voltage and current limit  The settings are stored  with a precision of better than 1 digit  Subsequent adjustments of the VOLTAGE and CURRENT  controls will have no effect    Because cancelling LOCK will cause the output settings to change if the VOLTAGE and  CURRENT control positions have been moved  warning reminders are given before LOCK is  cancelled  Press and hold the key to cancel LOCK     If the OUTPUT is off  the safe condition  the display will flash the    unlocked    settings twice before  the change is implemented  the LOCK lamp goes off     If the output is stillon  OP on  output on  will flash twice in the  display  followed by flashing of the new    unlocked    settings for 2 3  seconds  slowly at first  then faster  before the change is finally   implemented  the LOCK lamp goes o
69. ets poussoirs en plastique de chaque c  t   du capot sup  rieur  Utilisez la lame  d un petit tournevis pour lib  rer d abord la t  te du rivet  puis d  gager compl  tement le corps  de la fixation  Retirez les deux vis du panneau arri  re qui fixent le capot sup  rieur   glissez  le capot vers l arri  re et soulevez le     3  Modifiez les connexions du transformateur  des deux transformateurs sur le mod  le double   conform  ment au sch  ma ci dessous      230V Operation 115V Operation       BLEU MARRON BLEU MARRON    4  Remontez l appareil dans l   ordre inverse  Pour se conformer aux prescriptions des normes  de s  curit    la tension d alimentation indiqu  e sur le panneau arri  re doit   tre modifi  e pour  indiquer clairement le nouveau r  glage de tension     Fusible    Le fusible CA se trouve dans le compartiment    fusible dans la partie inf  rieure du connecteur  d entr  e IEC  Pour changer le fusible  retirez le cordon de phase et ouvrez le compartiment     fusible avec un outil adapt       Le type de fusible correct mesure 20 x 5 mm avec retardement HBC avec le classement suivant      230V 115V  Simple  1 6A T  3 15A  T   Double  3 15A  T  6 3A  T     Remplacer les fusibles uniquement par des fusibles du courant nominal requis et du type  sp  cifi    Il est interdit d utiliser des fusibles bricol  s et de court circuiter les porte fusibles     Cordon secteur    16    Brancher l appareil sur l alimentation secteur a l   aide du cordon secteur fourni  S il s av  re 
70. ff when the change is made        11    Releasing the LOCK key at any time while the display is flashing will abort the LOCK cancellation   Attempting to change the current limit range  see Setting up the Output section  or the voltage  span limits  see Voltage Span section  with LOCK enabled is not allowed  if attempted  the  message Unloc is shown briefly in the display and the LOCK indicator is also flashed  If the  output is also on when these actions are attempted the message turn oFF is first shown in  the display  accompanied by the output indicator flashing  followed by the message Unloc   with the LOCK indicator flashing      Using Voltage Span    The VOLTAGE SPAN  V Span  capability allows the end stop values of the VOLTAGE controls to  be redefined by the user such that the controls operate within a specific  narrower  voltage range   This not only has the advantage of protecting against the accidental application to the load of  voltages outside of the range  but also provides high resolution analogue control over the  specified voltage range using the full 300   rotation of the voltage controls     V Span is turned on or off with the ENABLE key  The  ENABLE lamp is lit when V Span is selected  The    factory default is Vmin   3V  Vmax   5V       Because turning V Span on will always change the output voltage  it can only be enabled or  cancelled with the output off  If attempts are made to enable or cancel V Span with the output on   the display will briefly show
71. forderlich sein  die Betriebsspannung zu andern  gehen Sie wie folgt vor     1  Stellen Sie sicher  dass das Gerat von der Netzstromversorgung getrennt ist     2  Entfernen Sie die Plastikdrucknieten an allen Seitenkanten des Deckels  Nehmen Sie einen  kleinen Schraubendreher zur Hand  um zuerst den Nietkopf und danach die gesamte Nieth  lse  herauszuhebeln  Entfernen Sie die beiden Schrauben auf der R  ckwand zur Befestigung des  Deckels   schieben Sie dann den Deckel nach hinten und nehmen Sie ihn ab     3  Andern Sie die Transformatoranschl  sse  beider Trafos im Falle des Doppelnetzger  ts  nach  folgender Zeichnung     230 V Betrieb 115 V Betrieb       BLAU BRAUN BLAU BRAUN    4  Die Wiedermontage erfolgt in umgekehrter Reihenfolge zum Ausbau  Um den  Sicherheitsvorschriften zu entsprechen  muss die auf der R  ckwand angegebene  Betriebsspannung so ge  ndert werden  dass die neue Einstellung der Betriebsspannung  deutlich zu erkennen ist     Sicherung    Die Wechselstromsicherung befindet sich im Sicherungsfach im unteren Teil des IEC  Netzsteckers  Zum Wechseln der Sicherung das Netzkabel abziehen und das Sicherungsfach mit  einem geeigneten Hilfsmittel   ffnen     Verwenden Sie eine Sicherung vom Typ 20 x 5 mm 250V HBC  tr  ge  mit folgenden Werten     230V 115V  Einfach  1 6A  T  3 15A  T   Doppel  3 15A  T  6 3A  T     Sicherstellen  dass nur Sicherungen des vorgeschriebenen Stromwerts und des vorgesehenen  Typs als Ersatz verwendet werden  Provisorische    Sicherung
72. fore reverting to show the actual output voltage now set     The percentage value can be shown at any time by pressing either the Vmin or Vmax key of the  Slave output  With either key held down the Slave display shows the percentage setting in the  form 90 0 Pent and the Slave Voltage controls can be used to set the ratio percentage  required  The ratio percentage can be set prior to Ratio Tracking being enabled  ENABLE lamp  off     The LOCK and VOLTAGE SPAN functions of the Master operate exactly as described previously   However  with Ratio Tracking enabled  the Slave Voltage controls can still be used to adjust the  ratio percentage of the Slave voltage even though the Master voltage is locked  See also the  Retained Slave Settings paragraph     13    Parallel    The MODE switch is set to PARALLEL  The instrument operates in true parallel mode with all of  the power available from the Master output which can then supply up to 6 amps  The Slave  output is disabled and its displays are turned off     In Parallel mode the value of the current limit is doubled for the same setting of the Current limit  control  including the 500mA range which becomes 1000mA max  as a warning  when Parallel  mode is first selected  the current display flashes twice before steadily displaying the new limit   Similarly  the current display is flashed twice when the mode is changed from Parallel to Tracking   as a warning that the Master output current limit has now halved     The LOCK and VOLTA
73. gnote   le message OtP triP est remplac   par la  tension et le courant pr  d  finis  l indicateur SETTINGS s allume   mais la sortie reste d  sactiv  e    chaque pression suivante sur la touche OUTPUT fait appara  tre bri  vement le message OtP  triP mais la sortie reste d  sactiv  e jusqu    ce que la condition de d  passement de  temp  rature soit termin  e     Affichage des parametres    Les limites de tension et de courant d  finies sont tou ours affich  es  lorsque la sortie est d  sactiv  e  mais peuvent aussi   tre lues apres  une pression sur la touche VIEW   l indicateur SETTINGS s allume  en cas de pression sur la touche VIEW        Verrouillage des param  tres    Une pression sur la touche LOCK verrouille num  riquement la limite de tension et de courant  d  finie  Les param  tres sont stock  s avec une pr  cision sup  rieure a 1 chiffre  Les ajustements  suivants des commandes VOLTAGE et CURRENT seront sans effet     Comme l annulation de LOCK provoque un changement des param  tres de sortie si la position  des commandes VOLTAGE et CURRENT a   t   modifi  e  des rappels d   avertissement sont  donn  s avant l annulation du LOCK     Appuyer et maintenir la touche enfonc  e pour annuler LOCK   Si la sortie est d  sactiv  e  l   tat s  r   l   cran fait clignoter les param  tres    non verrouilles    deux  fois avant l application du changement   l   indicateur LOCK s   teint     Si la sortie est toujours activ  e  le message OP on  sortie activ  e   clignote deux f
74. h     In common with all series regulated single ended power supplies  the unit is not capable of  sinking current provided from an external source  If a voltage greater than the set output voltage  of the unit is applied from an external source  the internal regulator will turn off and no current will  flow  if the output is turned on the voltage meter will read the applied voltage  No damage will  result providing the applied voltage does not exceed the maximum output voltage of the power  supply by more than 20 Volts     With the OUTPUT off the load is still connected to the power supply output stage  the output  voltage is simply set to zero  Do not apply external voltages to the power supply terminals in  excess of 20V above the rated output voltage  even with the output off  or damage may result     Over temperature Protection  An internal sensor will detect over temperature due to blocked airflow  fan failure or other circuit  fault  Over temperature will turn the output off  the OUTPUT indicator will flash  and the display  will show the message OtP triP   When the cause of the over temperature has been  removed  and the instrument has cooled down  the output indicator will go off but the message  OtP triP continues to show  Pressing the OUTPUT key once will change the display to show  the preset voltage and current  the SETTINGS indicator will be lit  but the output will remain off   pressing it a second time will turn the output on normally   If the OUTPUT key is pr
75. i nominali o in condizioni ambientali al di fuori di quelle specificate     ATTENZIONE  QUESTO STRUMENTO DEVE ESSERE COLLEGATO A TERRA    Una qualsiasi interruzione sia interna che esterna del collegamento a terra rende pericoloso  questo strumento  E proibito interrompere questo collegamento deliberatamente  L azione  protettiva non deve essere negata dall   uso di una prolunga priva conduttore di protezione     Quando lo strumento    collegato all   alimentazione  alcuni morsetti sono sotto tensione e  l apertura dei coperchi o la rimozione di parti  eccetto quei componenti accessibili senza l   uso di  attrezzi  pu   lasciare scoperti i morsetti sotto tensione  Prima di aprirla per eseguire regolazioni   manutenzione o riparazioni  l apparecchiatura deve essere staccata da tutte le sorgenti di  tensione    condensatori collegati all   alimentazione interna possono essere carichi anche dopo  aver staccato l alimentazione ma si scaricano in tutta sicurezza circa 1 minuto dopo aver staccato  la corrente    Per quanto possibile  si consiglia di evitare qualsiasi operazione di regolazione e riparazione  quando lo strumento    sotto tensione e  qualora fosse inevitabile  dette operazioni devono essere  eseguite da una persona specializzata in materia  che sia pienamente conscia del pericolo  presente     Quando sia chiaro che lo strumento    difettoso  o che ha subito un danno meccanico  un eccesso  di umidit    o corrosione a mezzo di agenti chimici  la sicurezza potrebbe esser
76. ichen Ventilators eingesetzt werden     Anschlusse    Alle Anschl  sse erfolgen auf der Ger  tevorderseite     Die Last sollte an die mit OUTPUT  Ausgang  gekennzeichneten positiven  roten  und negativen   schwarzen  Klemmen angelegt werden  Beide Klemmen sind galvanisch getrennt und k  nnen  daher an Erde gelegt werden     Die Fernf  hleranschl  sse f  r die Last  falls gew  nscht  erfolgen   ber die entsprechenden Plus       und Minus     SENSE Klemmen  Setzen Sie den Schalter LOCAL REMOTE auf REMOTE  wenn die Fernf  hlerfunktion eingesetzt werden soll  Setzen Sie den Schalter auf LOCAL zur  ck   wenn die Fernf  hlerfunktion nicht verwendet wird     L    Die mit   markierte Klemme ist mit dem Geh  use und dem Schutzleiter verbunden     27    Bedienung    In diesem Handbuch sind die Tasten  Steuerelemente und Buchsen auf der Frontplatte in  Gro  buchstaben dargestellt  z  B  CURRENT  OUTPUT und LOCK  Meldungen auf den 7   Segment LEDs werden in einer anderen Schriftart angegeben  z  B   turn oFF  OtP trip     Einschalten und Einschaltzustand       Der Netzschalter befindet sich unten links auf der Geratevorderseite  Nach dem Bet  tigen des  Netzschalters   I   wird auf der rechten Anzeige kurz die Firmware Version angezeigt  gefolgt von  der Spannungs  und Stromanzeige    Beim Einschalten ist das Gerat vom Werk aus so eingerichtet  dass der Ausgang abgeschaltet ist   Alle anderen Einstellungen entsprechen dem Zustand vor dem letzten Abschalten des Ger  ts     Der Gleichspann
77. ion bench power supplies  a  capacitor is connected across the output to maintain stability and good transient response  This  capacitor charges to the output voltage and loading of the output will produce a current pulse as  the capacitor discharges which is independent of the current limit setting     Current Meter Averaging   To reduce the measurement jitter with rapidly varying load  currents a 2 second time constant can be selected by pressing the  METER AVERAGE key  the indicator beside the key lights when  meter averaging is selected  Press the key again to CANCEL  meter averaging and return to the standard 20ms time constant        Efficiency  The power supply minimises dissipation by using electronic line frequency pre regulation to  maintain a low overhead voltage to the output regulators  In addition  to optimise operation at  extremes of line input voltage and DC output power  the transformer secondary is intelligently tap   changed by a relay  Hysteresis is used at the threshold point to prevent unnecessary switching  when the output is set at about that level  Apart from an audible    click    the user will be unaware  that the relay has switched  there will be no disturbance on the output     Connection to the Load    The load should be connected to the positive  red  and negative  black  OUTPUT terminals  Both  are fully floating and either can be connected to ground     Remote Sensing  The unit has a very low output impedance  but this is inevitably increased
78. iores a 20V sobre el voltaje de salida  nominal  incluso con la salida desactivada  ya que de otro modo se producir  n da  os     Protecci  n de sobretemperatura    Un detector interno detectar   sobretemperatura debida a una obstrucci  n en la circulaci  n del  aire  un ventilador averiado u otro fallo ocurrido en el circuito  Al producirse la sobretemperatura   la salida se desactivar    el indicador OUTPUT parpadear   y la pantalla visualizar   el mensaje  OtP triP  Una vez corregida la causa de la sobretemperatura y se haya enfriado el  instrumento  el indicador de salida se desactivar   pero el mensaje OtP triP continuar    visualiz  ndose  Pulsando una vez la tecla OUTPUT  la pantalla cambiar   para visualizar el  voltaje y la corriente preestablecidos  el indicador SETTINGS se encender    pero la salida  permanecer   desactivada  Al pulsar la tecla por segunda vez  la salida se activar   de manera  normal    Si la tecla OUTPUT se pulsa mientras el instrumento todav  a est   en sobretemperatura  el  indicador OUTPUT parpadea   el mensaje OtP triP ser   reemplazado por el voltaje  preestablecido  el indicador SETTINGS estar   encendido  pero la salida permanecer    desactivada  Cada pulsaci  n subsiguiente de la tecla OUTPUT hace visualizar brevemente el  mensaje OtP triP pero la salida permanecer   desactivada hasta que desaparece la condici  n  de sobretemperatura        50    Ajustes de visualizacion    El limite de corriente y el voltaje establecido son siempre  visu
79. lave  Lorsque vous maintenez l   une de ces deux touches enfonc  es  l   cran du  Slave affiche le param  tre de pourcentage sous la forme 90 0 Pent et les contr  les Slave  Voltage permettent de d  finir le pourcentage de ratio requis  Le pourcentage de ratio peut   tre  d  fini avant l activation de Ratio Tracking  indicateur ENABLE   teint      Les fonctions LOCK et VOLTAGE SPAN du Master fonctionnent exactement comme d  crit  pr  c  demment  Toutefois  lorsque Ratio Tracking est activ    les commandes de Slave Voltage  peuvent toujours   tre utilis  es pour r  gler le pourcentage de ratio de la tension du Slave  m  me  si la tension du Master est verrouill  e     Voir aussi le paragraphe Param  tres du Slave conserv  s     Parallel    L interrupteur MODE est d  fini sur PARALLEL  L instrument fonctionne v  ritablement en mode  parall  le  avec toute la puissance disponible a partir de la sortie Master qui peut ensuite fournir  jusqu      6 amp  res  La sortie Slave est d  sactiv  e et ses   crans sont   teints     En mode Parallel  la valeur de la limite actuelle est doubl  e pour le m  me param  tre de contr  le  de limite Current  y compris la plage 500 mA  qui devient 1000 mA au maximum      titre  d avertissement  la premi  re fois que le mode Parallel est s  lectionn    l   cran actuel clignote  deux fois avant d afficher en continu la nouvelle limite  De m  me  le courant s affiche deux fois  lorsque le mode bascule de Parallel    Tracking  pour vous avertir du fait
80. lecteur de  gauche indique maintenant la tension r  elle et celui de droite affiche le courant de charge r  el     La limite sup  rieure de la commande CURRENT peut alterner  entre le maximum pour ce mod  le et 500 mA avec des  pressions alternatives sur la touche 500 mA RANGE afin  d affiner le r  glage de la limite de courant et de la r  solution de  mesure  de 0 1 mA    500 mA    l indicateur plac      c  t   de la  touche s allume lorsque la plage 500 mA est s  lectionn  e        Pour changer la plage limite de courant  il faut d  sactiver la sortie   si la sortie est activ  e  le  message d avertissement turn oFF appara  t bri  vement    l   cran  l indicateur OUTPUT  clignote et la plage reste inchang  e    Tension continue  La tension de sortie est ajust  e    l aide des commandes VOLTAGE principale et affin  e   la  commande CURRENT d  finit le courant maximum qui peut   tre fourni     Courant continu    Si la r  sistance    la charge est suffisamment basse pour qu    la tension de sortie d  finie  un  courant sup  rieur au param  tre limite puisse circuler  le module d alimentation passe    18    automatiquement en fonctionnement de courant continu  La sortie de courant est ajust  e par la  commande CURRENT et les commandes VOLTAGE permettent de r  gler la tension maximale  pouvant   tre g  n  r  e     L indicateur CC s allume pour indiquer le mode de courant continu     Sortie d   intensit   instantan  e    La commande de limite d intensit   peut   tre r  gl  e pour
81. ment de mani  re non sp  cifi  e par ces instructions risque d affecter  la protection de s  curit   conf  r  e  Ne pas utiliser l instrument    l ext  rieur des tensions  d alimentation nominales ou de la gamme des conditions ambiantes sp  cifi  es     AVERTISSEMENT  CET INSTRUMENT DOIT ETRE RELIE A LA TERRE    Toute interruption du conducteur de terre secteur a l int  rieur ou a l ext  rieur de l instrument  rendra l instrument dangereux  Il est absolument interdit d effectuer une interruption a dessein  Ne  pas utiliser de cordon de prolongation sans conducteur de protection  car ceci annulerait sa  capacit   de protection     Lorsque l instrument est reli      son alimentation  il est possible que les bornes soient sous  tension et par suite  l ouverture des couvercles ou la d  pose de pi  ces     l exception de celles  auxquelles on peut acc  der manuellement  risque de mettre    d  couvert des pi  ces sous  tension  Il faut d  brancher toute source de tension   ventuelle de l appareil avant de l ouvrir pour  effectuer des r  glages  remplacements  travaux d entretien ou de r  parations  Les condensateurs  qui se trouvent dans le bloc d alimentation risquent de rester charg  s  m  me si le bloc  d alimentation a   t   d  connect   de toutes les sources de tension  mais ils se d  chargeront en  toute s  curit   environ 1 minute apr  s extinction de l alimentation    Eviter dans la mesure du possible d effectuer des r  glages  travaux de r  parations ou d entretien  lorsqu
82. mpostato  sull uscita slave  ll messaggio Un loc viene visualizzato nel display slave e il LOCK deve  essere disattivato  nella modalit   Indipendente  prima di poter utilizzare le modalit   Rilevamento     Vedi anche il paragrafo Impostazioni slave mantenute   Rilevamento isolato    Impostare l interruttore MODE su ISOLATED TRACKING  rilevamento isolato   Le due uscite  rimangono elettricamente isolate ma i controlli della tensione dell   uscita master indica l   identica  tensione della slave    controlli della Corrente della slave rimangono indipendenti  comprese le  funzioni di Range 500MA e di Media del misuratore     L isolamento elettrico permette di connettere le due uscite  per fornire  per esempio tensioni di  rilevamento di polarit   opposta o tensioni identiche connesse a riferimenti di sistema diversi  per  esempio  messa a terra digitale e messa a terra analogica      Le funzioni LOCK e VOLTAGE SPAN dell   uscita master operano esattamente come descritto  precedentemente e  dato che la tensione d uscita della slave segue la master  esse controllano  anche la tensione d   uscita della slave  Si noti che solo la tensione d uscita della slave       bloccata     quando viene utilizzato il LOCK della master  i controlli della corrente della slave rimangono  indipendenti  comprese le funzioni di Range 500mA e di Media del misuratore     Il tasto LOCK sull   uscita slave viene ignorato e la sua pressione provocher   la visualizzazione  temporanea del messaggio In trac 
83. n V Span fur den Slave Ausgang im unabhangigen Betrieb  INDEPENDENT  aktiviert ist  so  wird diese Einstellung bei Umschalten auf TRACKING Betrieb au  er Kraft gesetzt  jedoch bei  erneuerter Wahl von INDEPENDENT wieder aktiviert    Wenn    Ratio     Tracking    f  r den Slave Ausgang im TRACKING Betrieb aktiviert ist  so wird  diese Einstellung beim Umschalten auf INDEPENDENT oder PARALLEL au  er Kraft gesetzt   jedoch bei erneuter Wahl von TRACKING wieder aktiviert     Gleichzeitiges Ein  und Auschalten beider Ausg  nge    Die Tasten    Both On   Both Off     Beide Ein   Beide Aus  stehen zus  tzlich zu  den einzelnen OUTPUT Schaltern zur Verf  gung und erm  glichen das  gleichzeitige Ein  und Ausschalten beider Ausg  nge   ber einen  Schalterdruck  Diese Tasten sind in allen vier Betriebsarten betriebsf  hig        Wartung    Die Hersteller bzw  deren Vertretungen im Ausland bieten die Reparatur von Ger  ten an  bei  denen eine St  rung aufgetreten ist  Wenn der Eigent  mer die Wartungsarbeiten selbst  durchf  hren m  chte  hat er daf  r Sorge zu tragen  da   diese Arbeiten ausschlie  lich von  entsprechend qualifiziertem Personal und gem     Wartungshandbuch ausgef  hrt werden  das  direkt von den Herstellern oder deren Vertretungen im Ausland bezogen werden kann     Reinigung    34    Falls die Stromversorgung der Reinigung bedarf  einen mit Wasser oder einem milden Detergens  angefeuchteten Lappen benutzen  Anzeigefenster mit einem weichen  trockenen Lappen  polieren   
84. nie a  ce niveau environ  En dehors d un    clic audible     l utilisateur ignorera que le relais s est activ      cela ne perturbera pas la sortie     Connexion    la charge    La charge devra   tre connect  e aux bornes OUTPUT positive  rouge  et n  gative  noire   Les  deux sont enti  rement flottantes et l   une ou l   autre peuvent   tre connect  es    la masse     D  tection    distance    L unit   poss  de une imp  dance de sortie tr  s faible  mais elle est in  vitablement augment  e par  la r  sistance des fils de connexion  A hautes intensit  s  ceci peut se traduire par des diff  rences  significatives entre la tension source indiqu  e et la tension r  elle de la charge  deux fils de  raccordement de 2mQ chuteront de 0 2V    5 Amp  res  par exemple      Ce probl  me peut   tre minimis   en utilisant des fils de  raccordement courts et   pais  mais lorsque cela s av  re  n  cessaire  on peut le surmonter compl  tement en utilisant la  E    fonction de d  tection    distance  Ceci n  cessite de connecter   UT  les bornes de d  tection    la sortie sur la charge plut  t que sur  LOCAL  REMOTE  la source   ins  rer les fils dans les bornes    ressort SENSE  i   SENSE     d  tection  et les connecter directement    la charge  Basculez  le commutateur LOCAL REMOTE sur REMOTE   Pour   viter les probl  mes d instabilit   et de r  ponse transitoire  il convient d assurer un bon  couplage entre chaque fil de sortie et de d  tection  Pour ce faire  on peut torsader les fils  
85. ntional interruption is prohibited  The protective action must not be  negated by the use of an extension cord without a protective conductor     When the instrument is connected to its supply  terminals may be live and opening the covers or  removal of parts  except those to which access can be gained by hand  is likely to expose live  parts  The apparatus shall be disconnected from all voltage sources before it is opened for any  adjustment  replacement  maintenance or repair     Capacitors inside the power supply may still be charged even if the power supply has been  disconnected from all voltage sources but will be safely discharged about 10 minutes after  switching off power     Any adjustment  maintenance and repair of the opened instrument under voltage shall be avoided  as far as possible and  if inevitable  shall be carried out only by a skilled person who is aware of  the hazard involved     If the instrument is clearly defective  has been subject to mechanical damage  excessive moisture  or chemical corrosion the safety protection may be impaired and the apparatus should be  withdrawn from use and returned for checking and repair     Make sure that only fuses with the required rated current and of the specified type are used for  replacement  The use of makeshift fuses and the short circuiting of fuse holders is prohibited     Do not wet the instrument when cleaning it   The following symbols are used on the instrument and in this manual      Caution   refer to th
86. o be  switched off        However  it is not possible to guarantee that there will never be any unwanted transients as the  mode is switched and the recommendation is therefore that both outputs should always be  switched off before any mode change     12    Independent  Set the MODE switch to INDEPENDENT  The two outputs are completely independent and  electrically isolated  each can be set as described in the preceding Output Control section   It is not possible to switch from Independent mode to Tracking with LOCK set on the Slave  output  The message Un loc is shown in the Slave display and LOCK must first be switched  off  in Independent mode  before the Tracking modes can be used   See also the Retained Slave Settings paragraph    Isolated Tracking  Set the MODE switch to ISOLATED TRACKING  The two outputs remain electrically isolated but  the Voltage controls of the Master output set an identical voltage on the Slave output  The  Current controls of the Slave remain independent  including the 500mA Range and Meter  Average functions   The electrical isolation permits the two outputs to be connected to provide  for example  tracking  voltages of opposite polarity or identical voltages connected to different system references  e g   digital ground and analogue ground    The LOCK and VOLTAGE SPAN functions of the Master operate exactly as described previously  and  because the output voltage of the Slave tracks the Master  they control the Slave output  voltage as well  N
87. ois a l   cran  suivi par le clignotement des nouveaux  param  tres    non verrouill  s    pendant 2    3 secondes  un  clignotement lent  puis plus rapide   avant que le changement ne  soit finalement appliqu    l indicateur LOCK s   teint une fois le  changemlent effectu      Le relachement de la touche LOCK a tout moment pendant que l   cran clignote interrompra  l annulation du LOCK    Une tentative de changement de la plage limite de courant  voir la section Configuration de la  Sortie  ou des limites extr  mes de la tension  voir la section Ecart de tension  avec LOCK activ    n est pas admise   si une telle tentative est faite  le message Unloc appara  t bri  vement et  l indicateur LOCK clignote   galement  Si la sortie est   galement activ  e lorsque ces actions sont  tent  es  le message turn oFF appara  t en premier lieu    l   cran  accompagn   de l indicateur de  sortie qui clignote   suivi du message Unloc  avec l indicateur LOCK clignotant         Utilisation de l   cart de tension    La fonction VOLTAGE SPAN  V Span     cart de tension  permet    l utilisateur de red  finir les  valeurs d extr  mit   des commandes VOLTAGE de telle mani  re que les commandes fonctionnent  dans une plage de tension sp  cifique  plus   troite  Cela pr  sente non seulement l avantage de se  prot  ger contre l application accidentelle de la charge des tensions en dehors de la plage  mais  fournit   galement un contr  le analogique haute r  solution sur la plage de tension sp  cifi 
88. onnect  s en parall  le  la tension de sortie sera   gale    celle du  g  n  rateur ayant le plus grand r  glage de sortie  jusqu      ce que le courant consomm   d  passe  son r  glage de limite d intensit    moment auquel la sortie tombera au r  glage le plus   lev    suivant  et ainsi de suite  En mode d intensit   constante  les appareils peuvent   tre connect  s en  parall  le pour fournir une intensit     gale    la somme des r  glages de limite d intensit       Protection    La sortie dispose d une protection intrins  que contre les court circuits et est prot  g  e contre les  tensions inverses par une diode   le courant continu inverse ne doit pas d  passer 3 amp  res   m  me si les pointes transitoires peuvent   tre nettement plus   lev  es  Si la tension inverse  appliqu  e peut produire plus de courant que la limite d  finie et que la sortie est activ  e  la sortie  passera au niveau limite du courant  l indicateur CC clignotera  et son affichage pr  sentera la  tension inverse sur la diode de protection   si la sortie est d  sactiv  e  seul l indicateur CC  clignotera     Comme tous les modules d alimentation    terminaison unique et r  gul  s en s  rie  l unit   ne peut  pas collecter le courant provenant d une source externe  Si une tension sup  rieure    la tension  de sortie d  finie de l unit   est appliqu  e    partir d une source externe  le r  gulateur interne se  d  sactivera et aucun courant ne circulera   si la sortie est activ  e  le lecteur de tension
89. ornes positive  rouge  et n  gative  noire  marqu  es  OUTPUT  sortie   Les deux sont enti  rement flottantes et l   une ou l   autre peuvent   tre  connect  es    la masse    Les connexions de d  tection    distance sur la charge  si n  cessaire  sont r  alis  es    partir des  bornes positive     et n  gative     SENSE  d  tection   Placez le commutateur LOCAL DISTANT  sur REMOTE  DISTANT  lorsque la d  tection distante est requise  Replacez le sur LOCAL  lorsque la d  tection    distance n est pas utilis  e     al    La borne marqu  e   est connect  e au chassis et a la borne de mise a la terre     17    Fonctionnement    Dans ce manuel  les touches du panneau avant  les commandes et les prises sont indiqu  es en  majuscules  par exemple CURRENT  OUTPUT  LOCK  Les messages affich  s sur les voyants  DEL a 7 segments sont affich  s dans une police diff  rente  par exemple turn oFF  OtP  trip  Les fonctions suppl  mentaires du double instrument en mode quad sont d  crites  ensemble a la fin de ce chapitre     Conditions de mise en marche et de mise sous tension    L interrupteur d   alimentation  POWER  se trouve en bas a gauche du panneau avant  Lorsque  l interrupteur d alimentation est activ         le m  tre de droite indique bri  vement le num  ro de  version du microprogramme avant d afficher les Volts et Amp  res     A la mise sous tension  le r  glage par d  faut en usine est desactive  Tous les autres param  tres  seront les m  mes que lors du dernier arr  t de l ap
90. ostituito dalla tensione e  dalla corrente preimpostate  l   indicatore delle SETTINGS   si illuminer     ma l   uscita rimarr    inattiva  ogni ulteriore pressione del tasto causer   la breve apparizione del messaggio OtP  triP ma l uscita rimarr   inattiva fino a che non terminer   la situazione di sovratemperatura      Impostazioni di Visualizzazione    I limiti predefiniti della tensione e della corrente vengono sempre  mostrati quando l   uscita    inattiva  ma possono anche essere  visualizzati quando    attiva  premendo il tasto VIEW  in tal modo si  illumina l indicatore delle SETTINGS        Impostazioni di Blocco    40    La pressione del tasto LOCK causer   il blocco digitale del limite predefinito della tensione e della  corrente  Le impostazioni vengono memorizzate al numero pi   vicino  Le successive regolazioni  dei controlli della VOLTAGE e della CURRENT non avranno effetto     Poich   l annullamento del LOCK causer   la modifica delle impostazioni d   uscita se le posizioni  del controllo della VOLTAGE e della CURRENT sono state spostate  prima che il LOCK venga  annullato verranno visualizzati segnali di avvertimento     Premere e tenere premuto il tasto per annullare il LOCK     Se l OUTPUT    off  cio   in sicurezza  il display lampegger   per due volte le impostazioni     sbloccate    prima che la modifica venga attuata  quindi la luce LOCK si spegnera     Se l   uscita    ancora attiva  OP on  uscita on  lampegger   per due  volte sul display  seguita da
91. ote that only the output voltage of the Slave is    locked    when the Master LOCK  is used  the current controls of the Slave  including the 500mA Range and Meter Average  functions  remain independent   The LOCK key on the Slave output is ignored and pressing it causes the message In trac to  be shown momentarily in the Slave display as a reminder   It is possible to switch from Tracking mode back to Independent mode with LOCK still set on the  Master  The    Master     right hand output  settings stay    locked    but the settings of the left hand  output  are not locked   The Voltage Span keys of the Slave have a different function in Tracking mode  see next section     Isolated Ratio     Tracking  Set the MODE switch to ISOLATED TRACKING     Ratio Tracking is enabled by pressing the  ENABLE key in the Slave VOLTAGE SPAN  section  ENABLE lamp on        The instrument operates as described above for Tracking mode but the Slave voltage can be set  to a percentage  0  to 101   of the Master voltage using the Slave Voltage controls  The ratio is  then maintained as the Master voltage is varied    Pressing ENABLE again returns the Slave to standard Tracking mode  ENABLE lamp off     Ratio Tracking can only be enabled or disabled with the Slave output off  If the output is on the  display will briefly show the message turn oFF when ENABLE is pressed and the change will  not be implemented    Whenever Ratio Tracking mode is enabled the Slave display momentarily shows Pent on  be
92. pareil    L     tat de sortie dc a la mise sous tension peut   tre d  fini de mani  re a   tre     always off     toujours d  sactiv    ou    same as at last power off     le  m  me qu    la derni  re mise hors tension   Le param  tre peut   tre modifi    comme suit  Tout en maintenant enfonc  e la touche VIEW  Afficher    appuyez sur la touche OUTPUT  sortie      et maintenez la enfonc  e    l   cran affiche d   abord le param  tre actuel pendant 1 seconde  OP OFF si  le param  tre par d  faut en usine est toujours s  lectionn    avant de faire  clignoter le nouveau param  tre pendant 2 secondes  LAST Set dans ce  cas   Au bout de 2 secondes  le nouveau param  tre reste affich   en  permanence    l   cran et le changement est mis en oeuvre   rel  chez les  touches OUTPUT et VIEW     La r  p  tition de cette op  ration r  tablira le param  tre pr  c  dent  Notez que l   tat de mise sous  tension des deux sorties du double module doit   tre r  gl   individuellement        Contr  le de la sortie  Configuration de la sortie    Une fois l alimentation activ  e et la     sortie d  sactiv  e  la tension de sortie et la limite de  courant peuvent   tre pr  d  finis de mani  re pr  cises    l aide des commandes VOLTAGE et  CURRENT   le lecteur de gauche indique la tension d  finie  alors que celui de droite affiche le  courant maximum d  fini et que l indicateur SETTINGS  param  tres  est allum       Lorsque le commutateur de sortie est d  sactiv    l indicateur OUTPUT s allume   le 
93. quedaran seguramente  descargadas a alrededor de 1 minuto de haber desconectado la corriente     Todo ajuste  mantenimiento o reparaci  n del instrumento abierto bajo tension debe ser evitado  en lo posible pero si fuera ineludible  estos trabajos deben ser realizados exclusivamente por un  personal cualificado consciente del riesgo que implican     Si el instrumento fuera claramente defectuoso  hubiera sido sometido a un dafio mecanico  a  humedad excesiva o a corrosi  n quimica  su protecci  n de seguridad puede fallar y el aparato  debe sacarse de uso y devolverse para comprobaci  n y reparaci  n     Asegurese que s  lo se empleen fusibles de la clasificaci  n y tipo especificados para todo  recambio  Esta prohibido utilizar fusibles improvisados asi como el corto circuito de portafusibles     El instrumento no debe humedecerse al ser limpiado  Los simbolos a continuaci  n son utilizados  en el instrumento y en este manual     Advertencia   Remitirse a los documentos adjuntos  el uso  incorrecto puede dafiar al instrumento     Terminal a tierra  alimentaci  n principal OFF  desconectada     alimentaci  n principal ON  conectada     corriente alterna  ca     2 04    corriente continua  cc     45    Instalacion    Tension de la red de alimentacion    Compruebe que la tensi  n a que funciona el instrumento  sefialada en el panel trasero  es  adecuada para la red de suministro local  Si es necesario cambiar la tensi  n  haga lo siguiente     1  Asegure que el instrumento est  
94. r   implementata    Quando V Span    attivo  la portata del controllo MAIN VOLTAGE  tensione principale      esattamente da Vmin a Vmax quando il controllo FINE    impostato sulla met    segnalato sul    pannello con un e  Il controllo FINE di per s    pu   essere utile per impostare una regolazione pi    precisa di  1   dell ampiezza di tensione      41    Controllo modalita del Dual Quad mode       a    ISOLATED TRACKING        Le quattro modalit   di funzionamento del Dual Quad Mode sono  INDEPENDENT   7     gas  descritte qui sotto  la modalit   si cambia utilizzando la manopola          A           o MODE  modalita   Per prevenire l inserimento incidentale di tensioni    ae ES   indesiderate nei circuiti connessi alle uscite  nel momento della  ii i modifica entrambe le uscite verranno automaticamente disattivate            i   lt SLAVE Ee  LUE TURN OUTPUTS OFF iii      WHEN CHANGING MODE                          Tuttavia  dato non    possibile garantire la totale assenza di transienti indesiderati quando la  modalit   viene modificata  si raccomanda di disattivare sempre entrambe le uscite prima di  qualsiasi cambiamento di modalit       Indipendente    Impostare l   interruttore MODE  modalita  su INDEPENDENT  indipendente   Le due uscite sono  completamente indipendenti e isolate elettricamente  ognuna pu   essere impostata come  descritto nel capitolo precedente Controllo Uscita     Non    possibile passare da questa modalit   alla modalit   Rilevamento con il LOCK i
95. rformance B     d  EN61000 4 4  1995  Fast Transient  1kV peak  AC line   0 5kV peak  DC Outputs    Performance B     e  EN61000 4 5  1995  Surge  0 5kV  line to line   1kV  line to ground   Performance B     f  EN61000 4 6  1996  Conducted RF  3V  80  AM at 1kHz  AC line only  DC Output  connections  lt 3m not tested   Performance B     According to EN61326 the definitions of performance criteria are   Performance criterion A     During test normal performance within the specification limits        Performance criterion B     During test  temporary degradation  or loss of function or  performance which is self recovering        Performance criterion C     During test  temporary degradation  or loss of function or  performance which requires operator intervention or system reset occurs        Where Performance B is stated it is because DC Output regulation may deviate beyond  Specification limits under the test conditions  However  the possible deviations are still small and  unlikely to be a problem in practice     Note that if operation in a high RF field is unavoidable it is good practice to connect the PSU to  the target system using screened leads which have been passed  together  through an absorbing  ferrite sleeve fitted close to the PSU terminals    Cautions  To ensure continued compliance with the EMC directive observe the following precautions     a  after opening the case for any reason ensure that all signal and ground connections are  remade correctly and that c
96. ropean Communities     EMC  Emissions  a  EN61326  1998  Radiated  Class B  b  EN61326  1998  Conducted  Class B  c  EN61326  1998  Harmonics  referring to EN61000 3 2  2000     Immunity  EN61326  1998  Immunity Table 1  Performance B  referring to   a  EN61000 4 2  1995  Electrostatic Discharge  b  EN61000 4 3  1997  Electromagnetic Field  c  EN61000 4 11  1994  Voltage Interrupt  d  EN61000 4 4  1995  Fast Transient  e  EN61000 4 5  1995  Surge  f   EN61000 4 6  1996  Conducted RF    Safety  EN61010 1 Installation Category II  Pollution Degree 2     Choo With    CHRIS WILDING  TECHNICAL DIRECTOR    2 November 2007    EMC    This instrument has been designed to meet the requirements of the EMC Directive 89 336 EEC   Compliance was demonstrated by meeting the test limits of the following standards     Emissions    EN61326  1998  EMC product standard for Electrical Equipment for Measurement  Control and  Laboratory Use  Test limits used were     a  Radiated  Class B  b  Conducted  Class B  c  Harmonics  EN61000 3 2  2000  Class A  the instrument is Class A by product category     Immunity    EN61326  1998  EMC product standard for Electrical Equipment for Measurement  Control and  Laboratory Use     Test methods  limits and performance achieved were    a  EN61000 4 2  1995  Electrostatic Discharge   4kV air  4kV contact  Performance A   b  EN61000 4 3  1997  Electromagnetic Field  3V m  80  AM at 1kHz  Performance B   c  EN61000 4 11  1994  Voltage Interrupt  1 cycle  100   Pe
97. s Verhalten zu gewahrleisten  Dieser Kondensator l  dt sich bis zur  H  he der Ausgangsspannung auf und erzeugt beim Anschlie  en einer Ausgangslast durch seine  Entladung einen Stromimpuls  auf den die Strombegrenzung keinen Einfluss hat     Mittelwerte der Stromst  rkemessung    Um die Messschwankungen bei ver  nderlichen Lasten zu  reduzieren  kann durch Dr  cken auf die Taste METER AVERAGE  eine Zeitkonstante von 2 Sekunden gew  hlt werden   ist diese  Funktion aktiviert  so leuchtet eine Anzeige neben der Taste auf   Dr  cken Sie die Taste erneut  um diese Mittelung zu annullieren und  zur Standardzeitkonstante von 20 ms zur  ckzukehren        Wirkungsgrad    Das Netzger  t reduziert Leistungsverluste durch elektronische Vorregelung  um eine niedrige  Gesamtspannung an den Leistungsreglern zu erhalten  Dar  ber hinaus wird die Trafoanzapfung    ber ein Relais intelligent geregelt  um den Betrieb bei extremer Netzeingangsspannung bzw  DC  Ausgangsleistung zu optimieren  Am Schwellenwert wird eine Hysteresefunktion eingesetzt  um  unn  tiges Schalten in N  he dieses Werts zu verhindern  Von einem kaum h  rbaren    Klick     abgesehen  ist das Schalten des Relais unmerklich     am Ausgang ist keine St  rung bemerkbar     Anschluss der Last    Die Last sollte an die mit OUTPUT gekennzeichneten positiven  rot  und negativen  schwarz   Klemmen angelegt werden  Beide Klemmen sind galvanisch getrennt und k  nnen daher an Erde  gelegt werden     Fernf  hlerfunktion    Obwohl das 
98. setzter Polarit  t oder identische Spannungen f  r unterschiedliche  Bezugspotentiale liefern  z  B  digitale Masse und analoge Masse      Die Funktionen LOCK und VOLTAGE SPAN des Master Ausgangs arbeiten exakt wie oben  beschrieben und regeln aufgrund der aktivierten Synchronregelung auch die Slave   Ausgangsspannung  Beachten Sie  dass bei Verwendung der Master LOCK Funktion nur die    Ausgangsspannung des Slave    verriegelt    wird     die Stromregler des Slave  einschl  des 500mA  Bereichs und der Mittelungsfunktionen  lassen sich weiter unabh  ngig bedienen    Die LOCK Taste des Slave Ausgangs wird ignoriert  Beim Dr  cken dieser Taste erscheint  lediglich kurz die Meldung In trac auf der Slave Anzeige    Sie k  nnen auch bei aktivierter LOCK Funktion am Master vom Tracking Betrieb auf  unabhangigen Betrieb zur  ckschalten  In diesem Fall bleiben die Einstellungen des rechten  Master Ausgangs    verriegelt     die Einstellungen des linken Ausgangs k  nnen dagegen frei  gew  hlt werden    Die Spannungsbereichstasten des Slave erhalten im Tracking Betrieb eine andere Funktion      siehe hierzu den n  chsten Abschnitt     Isolierte prozentuale Synchronregelung  Drehen Sie den MODE Schalter auf ISOLATED TRACKING     Aktivieren Sie diese Betriebsart  indem Sie die  Taste ENABLE im Bereich VOLTAGE SPAN  des Slave Ausgangs dr  cken  ENABLE  Leuchte an           Das Ger  t arbeitet wie im vorherigen Abschnitt beschrieben  jedoch kann die Slave Spannung mit  dem Slave Spannungsr
99. splay della corrente  lampeggia due volte quando la modalit   viene modificata da Parallelo a Rilevamento  come  avvertimento che il limite di corrente dell uscita Master    stata dimezzata     Le funzioni LOCK e VOLTAGE SPAN Master funzionano esattamente come descritto in  precedenza     possibile tornare dalla modalit   Parallelo a quella Rilevamento  e viceversa  con il  LOCK ancora impostato sull   uscita master  entrambi i controlli della Tensione e della Corrente  della master rimangono su LOCK  come precedentemente descritto  Tuttavia  il reale limite di  corrente impostato dell uscita master si raddoppier    passando da Rilevamento a Parallelo  o si  dimezzer    passando da Parallelo a Rilevamento  ancora  nonostante sia impostato il LOCK  ma  il display della corrente lampeggia per avvertire che ci   si sta verificando     Impostazioni slave mantenute    Se V Span    attivo sull   uscita Slave  in modalit   Indipendente     disabilitato quando viene  selezionata la modalit   TRACKING  rilevamento   ma riattivato quando viene riselezionato  INDEPENDENT     Se Rilevamento del rapporto        attivo sull uscita slave in modalit   TRACKING  viene  disabilitato quando vengono selezionati INDEPENDENT o PARALLEL  ma riattivato quando  viene riselezionato TRACKING       tasti Entrambe on   Entrambe off sono un aggiunta ai commutatori  d   OUTPUT singoli e permettono di attivare o disattivare entrambe le uscite  simultaneamente con la pressione di un singolo tasto    tasti En
100. ssa in parallelo con altre per produrre correnti pi   alte  Quando diverse  unit   sono collegate in parallelo  la tensione d uscita sar   la stessa di quella dell unit   con le  impostazioni di tensione d   uscita maggiore  fino a che la sottrazione di corrente non superer    l impostazione del suo limite di corrente  quindi l uscita scender   a quella dell impostazione pi    bassa seguente  e cos   via  In modalit   corrente costante  le unit   possono essere collegate in  parallelo per fornire una corrente uguale alla somma delle impostazioni dei limiti di corrente     Protezione    L uscita dispone di una protezione intrinseca contro i cortocircuiti ed    protetta contro i ritorni di  tensione da un diodo  la corrente continua di ritorno non deve eccedere 3 Ampere  bench   i  transienti possano essere molto pi   elevati  Se i ritorni di tensione che si verificano possono  originare pi   corrente del limite di corrente stabilito  e l uscita    attiva  questa entrer   nel limite di  corrente  l indicatore corrente costante lampegger    e il suo display indicher   il ritorno di tensione  sul diodo di protezione  se l   uscita    disattivata  lampegger   solo l indicatore corrente costante     Come in tutti gli alimentatori a singola estremit   regolati in serie  l   unit   non    in grado di  incamerare corrente da una fonte esterna  Se viene applicata da una fonte esterna una tensione  maggiore di quella d uscita impostata per l   unit    il regolatore interno si spegner   
101. sul display della slave  come promemoria        possibile tornare dalla modalit   Rilevamento a quella Indipendente con il LOCK ancora  impostato sull   uscita master  Le impostazioni    Master     uscita di destra  rimangono    bloccate    ma  quelle dell   uscita di sinistra no       tasti dell Ampiezza di tensione dell uscita slave hanno una funzione diversa in modalit    Rilevamento  vedere il prossimo capitolo    Rilevamento del rapporto     isolato  Impostare l   interruttore MODE su ISOLATED TRACKING     Rilevamento del rapporto    attivato premendo il  tasto ENABLE nella sezione VOLTAGE SPAN  Slave  indicatore ENABLE acceso        Lo strumento funziona come descritto sopra per la modalit   Rilevamento  ma la tensione slave  pu   essere impostata su una percentuale  da 0 a 101  di quella master utilizzando i controlli  Tensione slave  Il rapporto viene quindi mantenuto anche se la tensione master viene modificata     42    Una nuova pressione di ENABLE fara tornare la slave nella modalita Rilevamento standard   indicatore ENABLE spento      Il Rilevamento del rapporto pu   venire abilitato o disabilitato solo con le uscite disattivate  Se  l uscita    sul display mostrer   per un momento il messaggio turn oFF quando viene premuto  ENABLE e la modifica non verr   implementata     Ogni volta che la modalit   Rilevamento del rapporto    abilitata  il display slave mostra per breve  tempo Pent on prima di tornare a visualizzare la reale tensione d uscita ora impostata     
102. t  verwendet wird     29    Serielle oder Parallelschaltung mit anderen Spannungsquellen    A    Der Ausgang des Netzger  ts ist galvanisch getrennt und kann mit anderen Netzger  ten in Reihe  geschaltet werden  um hohe Gleichstromspannungen bis zu 300 V DC zu erzeugen     L    Die maximal zul  ssige Spannung zwischen einer Anschlussklemme und Erde     betr  gt  300 V DC     ACHTUNG  Spannungen dieser Gr    enordnung sind   u  erst gef  hrlich  Daher m  ssen die  Ausgangsklemmen bei Verwendung derartiger Spannung unbedingt vor Ber  hrung gesch  tzt  werden  Auf keinen Fall d  rfen die Ausgangsklemmen in einem solchen Fall ber  hrt werden   S  mtliche Anschl  sse an den Klemmen d  rfen erst dann erfolgen  wenn alle betreffenden  Netzger  te ausgeschaltet sind     Zu beachten ist  dass das Ger  t nur als Stromquelle dient und keine Str  me ableiten kann  d  h   es k  nnen keine gegenphasigen Ger  te angeschlossen werden     Das Ger  t kann auch mit anderen Netzteilen parallel geschaltet werden  um eine h  here  Stromabgabe zu erzielen  Werden mehrere Ger  te parallel geschaltet  entspricht die  Ausgangsspannung dem Ger  t mit der h  chsten Ausgangsspannung  Dies gilt nur  solange der  Strombegrenzungswert des betreffenden Ger  ts nicht erreicht wird  Ist dies der Fall  f  llt die  Ausgangsspannung auf die n  chsth  chste Einstellung ab  usw  Bei Konstantstrombetrieb k  nnen  mehrere Ger  te parallel geschaltet werden  um einen Strom mit der Summe der jeweiligen  Stromgrenzwerte
103. t gestattet     bei einem Versuch erscheint kurz die Meldung Unloc im Display und die  LOCK Anzeige blinkt auf  Wird dieser Versuch bei eingeschaltetem Ausgang unternommen   erscheint zun  chst die Meldung turn oFF im Display  zusammen mit blinkender  Ausgangsanzeige   gefolgt von der Meldung Unloc  mit blinkender LOCK Anzeige      Verwendung des Spannungsbereichs  Die Funktion VOLTAGE SPAN  V Span  erm  glicht die Neudefinierung der Grenzwerte f  r die  VOLTAGE Regler  sodass der Anwender die Regler nur in einem speziellen  begrenzten  Spannungsbereich einstellen kann  Dies hat nicht nur den Vorteil  dass das versehentliche  Anlegen einer falschen Spannung an die Last verhindert wird  sondern auch  dass sich der nun  begrenzte Spannungsbereich unter voller Nutzung des Einstellbereichs von 300   mit dem  Analogregler feinf  hliger einstellen l  sst     V Span wird mit der Taste ENABLE aktiviert  Die  ENABLE Lampe leuchtet auf  wenn V Span gew  hlt    ist  Der voreingestellte Wert ist Vmin   3V  Vmax   5V             Da sich bei der Aktivierung von V Span immer die Ausgangsspannung andert  kann diese  Funktion nur bei ausgeschaltetem Ausgang aktiviert bzw  deaktiviert werden   beim Versuch V   Span bei eingeschaltetem Ausgang zu  de aktivieren  erscheint kurz die Meldung turn oFF  um den Anwender darauf aufmerksam zu machen  dass der Ausgang abgeschaltet werden muss     31    Um neue Werte f  r Vmin oder Vmax einrichten zu k  nnen  muss die V Span Funktion deaktiviert  sein   
104. tage change in the Slave voltage setting      change in Slave voltage     change of Master voltage   0 1   10mV    The Master output operates as a single output power supply with twice the  current capability  0 2mA to 6A   The Slave is disabled  its displays are  both off     Each output has an independent DC On Off control  these additional keys  can be used to turn both outputs on or off simultaneously  These keys  operate in all four modes     230V AC or 115V AC   10   50 60Hz  Installation Category Il  Single  280VA max  Dual  560VA max     5  C to  40  C  20  to 80  RH      40  C to   70  C   Indoor use at altitudes up to 2000m  Pollution Degree 2     Intelligent variable speed low noise fan assists convection  Over   temperature trip shuts down output if internal temperatures exceed  predetermined thresholds     Complies with EN61010 1  Complies with EN61326    Single  107mm x 131mm    rack 3U  x 288mm  excluding feet  knobs and  terminals    Dual  214mm x 131mm    rack 3U  x 288mm  excluding feet  knobs and  terminals     Single  4 5kg  Dual  6 7kg     EC Declaration of Conformity    We Thurlby Thandar Instruments Ltd  Glebe Road  Huntingdon  Cambridgeshire PE29 7DR  England    declare that the  PL155  PL303  PL601  amp  PL303QMD Power Supplies    meet the intent of the EMC Directive 2004 108 EC and the Low Voltage Directive 2006 95 EC   Compliance was demonstrated by conformance to the following specifications which have been  listed in the Official Journal of the Eu
105. te massima che pu   essere fornita     Corrente costante    38    Se la resistenza di carico    cos   bassa che  all impostazione della tensione d   uscita  una corrente  maggiore dei limiti correnti impostati fluttuerebbe  l alimentatore passer   automaticamente a  funzionare a corrente costante  L uscita di corrente viene regolata utilizzando il controllo  CURRENT e i controlli VOLTAGE impostano la tensione massima che pu   essere generata   L indicatore CC si illumina e mostra la modalit   corrente costante        Uscita di corrente istantanea    Il controllo del limite di corrente pu   essere impostato per limitare la corrente d   uscita continua a  livelli inferiori a 1mA  portata 0 1mA su 500mA   Tuttavia  come in tutti gli alimentatori da banco   un capacitore    connesso all uscita per mantenere la stabilit   e una buona risposta transiente   Questo capacitore si carica alla tensione d   uscita  un carico in uscita produrr   cos   un impulso di  corrente dato che il capacitore si scarica  indipendente dalle impostazioni del limite di corrente     Media di misurazione di corrente    Per ridurre il jitter di misurazione con correnti di carico che  variano rapidamente si pu   selezionare un tempo costante di 2  secondi  premendo il tasto METER AVERAGE  media del  misuratore   Per CANCEL  annullare  la media di misurazione e  tornare al tempo costante standard di 20ms  premere di nuovo il       Rendimento    L alimentatore minimizza lo spreco usando una preregolazione ele
106. the Manufacturers or their agents overseas     Cleaning    14    If the instrument requires cleaning use a cloth that is only lightly dampened with water or a mild  detergent     WARNING  TO AVOID ELECTRIC SHOCK  OR DAMAGE TO THE INSTRUMENT  NEVER  ALLOW WATER TO GET INSIDE THE CASE  TO AVOID DAMAGE TO THE CASE NEVER  CLEAN WITH SOLVENTS     7   7  Securite  Cet instrument est de Classe de s  curit   1 suivant la classification IEC et il a   t   construit pour  satisfaire aux imp  ratifs EN61010 1  Imp  ratifs de s  curit   pour le mat  riel   lectrique en vue de  mesure  commande et utilisation en laboratoire   Il s agit d un instrument d installation Cat  gorie Il  devant   tre exploit   depuis une alimentation monophas  e habituelle     Cet instrument a   t   soumis    des essais conform  ment    EN61010 1 et il a   t   fourni en tout    tat de s  curit    Ce manuel d instructions contient des informations et avertissements qui doivent    tre suivis par l utilisateur afin d assurer un fonctionnement de toute s  curit   et de conserver  l instrument dans un   tat de bonne s  curit       Cet instrument a   t   con  u pour   tre utilis   en interne dans un environnement de pollution  Degr   2  plage de temp  ratures 5  C a 40  C  20    80  HR  sans condensation   Il peut   tre  soumis de temps    autre    des temp  ratures comprises entre  5  C et  10  C sans d  gradation  de sa s  curit    Ne pas l utiliser lorsqu il y a de la condensation     Toute utilisation de cet instru
107. trambe on    Entrambe off funzionano in tutte e quattro le modalit   di configurazione        43    Manutenzione      Produttori o i loro agenti all estero faranno le riparazioni necessarie in caso di guasto  Qualora  l utente desiderasse eseguire il lavoro di manutenzione  tale lavoro deve essere fatto solo da  personale qualificato e usando il manuale di servizio che pu   essere acquistato direttamente dai  Produttori o dai loro agenti all   estero     Pulizia    44    Se si deve pulire il dispositivo di alimentazione  usare uno strofinaccio appena bagnato con  acqua o con un detergente neutro  Pulire la finestrella di visualizzazione con un panno asciutto e    morbido     ATTENZIONE  PER EVITARE SCOSSE ELETTRICHE ED EVENTUALI DANNI AL  DISPOSITIVO DI ALIMENTAZIONE  NON PERMETTERE MAI ALL ACQUA DI ENTRARE  ALL   INTERNO DELL   ALLOGGIAMENTO  PER EVITARE DANNI ALL   ALLOGGIAMENTO E  ALLA FINESTRELLA DI VISUALIZZAZIONE  NON PULIRE MAI CON SOLVENTI     Seguridad    Este es un instrumento de Clase de Seguridad   seg  n la clasificaci  n del IEC y ha sido disefiado  para cumplir con los requisitos del EN61010 1  Requisitos de Seguridad para Equipos El  ctricos  para la Medici  n  Control y Uso en Laboratorio   Es un equipo de Categoria Il que debe ser  usado con un suministro monof  sico normal     Este instrumento se suministra habiendo sido comprobado segun la norma EN61010 1  El  manual de instrucciones tiene informaci  n y advertencias que deben aplicarse para garantizar la 
108. tre activ      l aide de la  touche ENABLE si Vmax    Vmin   0 1V    si cette condition n est pas remplie  le message Set  Err appara  t bri  vement et la fonction V Span n est pas mise en ceuvre     Lorsque V Span est activ    la plage de la commande MAIN VOLTAGE est exactement de Vmin a    Vmax quand la commande FINE est r  gl  e    son point interm  diaire  marqu   sur le panneau par  un e  La commande FINE elle m  me peut   tre utilis  e pour r  gler plus pr  cis  ment la valeur sur   1   de l   cart de tension      Mode Control  Controle de mode  du Quad Mode Dual       Les quatre modes de fonctionnement du Quad Mode Dual sont  d  crits ci dessous   on modifie ce mode    l   aide de la molette  MODE  Pour   viter l application accidentelle de tensions  impr  vues aux circuits connect  s aux sorties  le changement  de mode provoque toujours une d  sactivation des deux sorties     Toutefois  on ne peut pas garantir qu il n y aura jamais de courants transitoires ind  sirables lors  du changement de mode  et il est donc recommand   que les deux sorties soient toujours  d  sactiv  es avant tout changement de mode     Independent    D  finissez le MODE sur INDEPENDENT  Les deux sorties sont alors enti  rement ind  pendantes  et isol  es   lectriquement  chacune pouvant   tre d  finie comme d  crit dans la section  pr  c  dente  Contr  le de sortie     Il n est pas possible de basculer du mode Independent au mode Tracking avec LOCK d  fini sur la  sortie Slave  Le message Un lo
109. ttronica per mantenere una  bassa tensione massima ai regolatori d uscita  Inoltre  per ottimizzare il funzionamento agli  estremi della tensione d   entrata dell alimentazione e all uscita DC  un rel   intelligente cambia la  presa del trasformatore secondario  L isteresi    utilizzata al punto limite per evitare che lo faccia  se non necessario  quando l   uscita    impostata pi   o meno a quel livello  A parte sentire un    clic      l utente non potr   sapere se il rel   si    spostato  all uscita non si verificheranno variazioni     Connessione al carico    Il carico deve essere connesso ai terminali d OUTPUT positivo  rosso  e negativo  nero    Entrambi sono completamente liberi e possono essere connessi a terra     Sensori remoti    L unit   ha un impedenza d uscita molto bassa  che viene inevitabilmente aumentata dalla  resistenza dei cavi di connessione  A correnti pi   elevate  ci   pu   portare a differenze significative  tra la tensione della fonte indicato e quella di carico reale  due cavi di connessione da 20mQ  porteranno 0 2V a 5 Ampere  per esempio      Questo problema pu   essere minimizzato utilizzando cavi  corti e spessi  ma se necessario pu   essere completamente  superato utilizzando la funzione di sensore remoto     Ci   richiede la connessione dei terminali dei sensori all uscita  del carico invece che alla fonte  inserire i cavi nei terminali  del SENSE  sensore  alla fonte e connettere direttamente al  inni carico  Ruotare lo switch LOCAL REMOTE su
110. ungsausgang kann so eingerichtet werden  dass er beim  Einschalten des Ger  ts entweder immer ausgeschaltet ist oder den Zustand  vor dem letzten Ausschalten des Gerats annimmt  Diese Einstellung kann wie  folgt ge  ndert werden  Bei gedr  ckter VIEW Taste  die Taste      OUTPUT  drucken und halten     auf dem Display erscheint nun 1 Sekunde lang die  aktuelle Einstellung  OP OFF falls die Werksvoreinstellung gew  hlt ist    Anschlie  end zeigt das Display 2 Sekunden lang blinkend die neue  Einstellung an   LASt Set in diesem Fall   Nach 2 Sekunden wird die neue  Einstellung kontinuierlich angezeigt und die Anderung durchgefiihrt  Geben  Sie nun die Tasten OUTPUT und VIEW frei    Wenn Sie diesen Vorgang wiederholen wird die Einstellung wieder ruckgangig gemacht     Beachten Sie  dass der Einschaltzustand des Doppelnetzger  ts fur jeden Ausgang einzeln  eingerichtet werden muss     Ausgangsregelung  Einrichten des Ausgangs       Bei eingeschalteter Stromversorgung und ausgeschaltetem     OUTPUT  Ausgang  k  nnen Sie  die Spannungs  und Strombegrenzung mit den Reglern VOLTAGE und CURRENT pr  zise regeln   Die linke Anzeige zeigt die eingestellte Spannung und die rechte Anzeige den maximalen Strom  an   die SETTINGS Anzeige leuchtet auf     Bei eingeschaltetem Ausgang leuchtet die OUTPUT Anzeige auf     das linke Messinstrument  zeigt jetzt die tats  chliche Spannung und das rechte Messinstrument den aktuellen Laststrom     Der obere Grenzwert f  r den CURRENT Regler kann durch 
    