1. INSTRUCTION MANUAL Microcentrifuge Cat No N2631 0007 www starlabgroup com ENGLISH 1 DEUTSCH 4 FRANCAISE 7 ITALIANO 10 DECLARATION OF CONFORMITY STARLAB certifies that N2631 0007 Microcentrifuge with 2 Rotors for Microtubes amp PCR Strips has been manufactured and inspected in accordance with the following International and European standards 2006 95 EC Low Voltage Directive 2004 108 EC Electromagnetic Compatibility Directive Harmonized Standards EN 61010 1 Lab Equipment EN 61010 2 020 Lab Equipment Centrifuges EN 61326 1 2006 Lab Equipment EMC As an ISO 9001 and ISO 13485 certified company our working procedures and processes are checked and audited regularly Additionally the quality of our products is continously monitored STARLAB International GmbH ENGLISH STARLAB MICROCENTRIFUGE Cat No N2631 0007 General Information The STARLAB Centrifuge is supplied with two rotors one standard for microtubes and one strip for 0 2ml PCR single or strip tubes The standard rotor is designed to centrifuge up to six individual 1 5 2 Oml plastic microcentrifuge tubes and will also accept 0 4ml 0 5ml tubes when used with the adapters supplied The strip tube rotor is designed to centrifuge two 8 x 0 2ml strip tubes and will also accept up to 16 individual 0 2ml tubes Both rotors are designed for applications requiring relatively low g forces
2. 1 5 2 Oml mais des tubes de 0 4ml 0 5ml peuvent tre utilis s gr ce l adaptateur fourni Le rotor pour barrettes peut contenir deux barrettes de 8 tubes PCR 0 2ml ou 16 tubes indivi duels de 0 2ml Ces deux rotors sont faits pour des applications ne n cessitant pas une vitesse lev e comme la microfiltration les s parations de cellules ou centrifugation rapide Lisez ce manuel attentivement avant d utiliser cette microcentrifugeuse Garantie La centrifugeuse et les rotors sont garantis un an Cette garantie cesse en cas de mauvaise utilisation de l appareil d utilisation de pi ces d tach es ou d accessoires non standards ou de modifications non autoris es de la centrifugeuse ou des rotors La garantie ne couvre pas l usure normale du rotor ou tout dommage caus par une exposition aux radiations aux d tergents ou un vissage excessif Les fusibles ne sont pas couverts par la garantie Changement de rotors Les rotors se changent facilement en utilisant la cl all ne fournie Rep rez la vis situ e la base du rotor Desserrez la vis avec la cl et retirez le rotor Placez l autre rotor au dessus de la tige du moteur Ne pas appuyer trop fortement le rotor sur le moteur de mani re ne pas craser la partie en caoutchouc Serrez la vis avec la cl NE PAS TROP SERRER ce qui pourrait endommager le rotor et le moteur Utilisation Avant d utiliser la centrifugeuse v rifier que le bouton d alimentation est sur la p
3. dieser Bedienungsanleitung beschrieben benutzen e das Ger t mit einem nicht ordnungsgem an der Rotorwelle befestigten Rotor bedienen e Probengef e im Ger t bef llen Versch ttete Fl ssigkeit kann das Ger t besch digen e das Ger t mit nur einem Gef bedienen e die H nde im Bereich des Rotors halten bevor das Ger t vollst ndig still steht e das Ger t w hrend des laufenden Betriebes bewegen e L sungsmittel oder entflammbare Fl ssigkeiten in der N he des Ger tes oder anderen elek trischen Ger ten benutzen e brennbare explosive oder tzende Fl ssigkeiten zentrifugieren e gef hrliche Materialien au erhalb eines Abzuges oder eines geeigneten Sicherheitsbereiches zentrifugieren Immer e den Rotor gleichm ig beladen Das Gewicht je Gef darf 3 g nicht berschreiten e die Zentrifuge m glichst in der N he der Steckdose aufstellen e ausschlie lich Kunststoffgef e benutzen die f r Zentrifugalkr fte von mindestens 2 000 x G ausgelegt sind Reinigung Benutzen Sie fur die Reinigung des Ger tes ein feuchtes Tuch und ein mildes nicht tzendes Detergens pH lt 8 Nach der Reinigung stellen Sie sicher dass alle Teile sorgf ltig getrocknet sind bevor Sie das Ger t wieder in Betrieb nehmen Tauchen Sie das Ger t nicht in Fl ssigkeiten oder berf hren Sie Fl ssigkeiten nicht Uber dem Ger t Bevor Sie eine Reinigungs oder De kontaminationsmethode anwenden die von den oben aufgefi
4. e o gli adattatori devono essere sempre caricati simme tricamente per assicurare l equilibrio adeguato Precauzioni MAI e usare la centrifuga diversamente da quanto specificato su queste istruzioni e utilizzare la centrifuga senza un rotore attaccato adeguantamente all albero e riempire le provette gi nel rotore Il versamento di liquido potrebbe danneggiare l unit e far funzionare la centrifuga con solo una strip di provette e inserire le mani nell area rotore fino a che questo non completamente fermo e spostare la centrifuga mentre il rotore in azione e usare solventi o materiali infiammabili vicino allo strumento e centrifugare materiali infiammabili esplosivi o corrosivi e centrifugare materiali rischiosi SEMPRE e caricare il rotore simmetricamente cosicch ogni provetta sia controbilanciata da un altra Il peso di ogni provetta non deve eccedere i 3 0g e posizionare la centrifuga vicino ad una presa della corrente elettrica e utilizzare solo provette per microcentrifuga di plastica destinate a sopportare una forza centrifuga di almeno 2 000 xG Pulizia Per pulire la centrifuga utilizzare un panno umido e un detersivo delicato e non corrosivo pH lt 8 Dopo la pulizia assicurarsi che tutte le parti siano asciutte prima di utilizzare lo strumento Non immergere la centrifuga in liquidi e non far traboccare liquidi Prima di utilizzare metodi di pulizia o decontaminazione ad eccezioni di quelli sopra descritt
5. such as microfiltration cell separation and quick spin downs from the walls of tubes Please read this manual thoroughly before attempting to operate the centrifuge Warranty The centrifuge and rotor are covered by a one year warranty which covers the centrifuge and rotor This warranty is void in the event of incorrect operation use of non standard spare parts or accessories and unauthorised modification of the rotor or centrifuge The rotor warranty does not cover normal wear and tear nor does it cover damage and or weakening caused by radioac tive contamination cleaning agents or overtightening of the allen screw Fuses are not covered by the warranty Exchanging Rotors The rotors are easily exchanged using the allen wrench provided Locate the set screw on the rotor shaft below the rotor head Using the wrench loosen the set screw and pull up the rotor to remove Place the other rotor into position on the motor shaft Take care not to press the rotor down so far as to compress the rubber collar at the base of the shaft Tighten the screw using the allen wrench until finger tight DO NOT OVERTIGHTEN as this will cause damage to the rotor and the motor shaft Operation Before operating the centrifuge be sure that the power switch is in the ON position To begin a run simply close the lid of the centrifuge No other controls are required To stop rotation press down on the lid release tab on the front of the unit This will release
6. F Vitesse 6000 tour min RCF 2000 xG rotor standard 1177 xG rotor pour barrettes La microcentrifugeuse STARLAB est fournie avec 1 cordon d alimentation 2 rotors un standard et un pour barrettes 6 adaptateurs pour tubes 0 5ml 1 cl allen pour changer les rotors ITALIANO MICROCENTRIFUGA STARLAB Codice N2631 0007 Informazioni generali La centrifuga STARLAB viene fornita con due rotori uno standard per microprovette e uno strip per provette per PCR da 0 2ml singole o in strip Il rotore standard adatto a centrifugare fino a 6 provette per microcentrifuga da 1 5 2 0ml e accetta anche provette da 0 4ml 0 5ml se utilizzato con l adattatore fornito Il rotore per provette in strip adatto a strip da 8 provette da 0 2ml e accetta anche fino a 16 provette da 0 2ml Entrambi i rotori sono adatti ad applicazioni richiedenti una forza g relati vamente bassa come microfiltrazioni separazioni cellulari e distacco rapido dalle pareti delle provette Leggere attentamente questo manuale prima di utilizzare la centrifuga Garanzia La centrifuga ed il rotore sono coperti da garanzia annuale che comprende la microcentrifuga ed il rotore Questa garanzia non valida in caso di utilizzo non corretto uso di pezzi di ricambio o accessori non standard e modifiche non autorizzate del rotore o della centrifuga La garanzia del rotore non copre la normale usura non copre il danno o l indenbolimento dovuto a con taminazion
7. Henri Barbusse 92220 Bagneux France Tel 33 0 1 45 3652 80 Fax 33 0 1 45 3604 86 info starlab france com STARLAB S r l Via Corelli 36 5 4 34 Milano www starlabgroup com aly Et GR Fax 39 0 2 7020 1033 L A B V2 02 2012 info starlabitalia it
8. e radioattive agenti sgrassanti o eccessivo avvitamento di tutte le viti fusibili non sono coperti da garanzia Cambiamento dei rotori Il rotori sono facilmente cambiabili tramite la chiave fornita Posizionare la vite di arresto nell albero del rotore sotto la testa dello stesso Tramite la chiave allentare la vite di arr esto e sollevare il rotore e rimuoverlo Disporre l altro rotore nell albero Fare attenzione a non comprimere il rotore fino all anello di gomma del rotore Stringere bene la vite usando la chiave fino alla barretta NON STRINGERE ECCESSIVAMENTE poich si potrebbe danneggiare il rotore e l albero del motore Funzionamento Prima di utilizzare la centrifuga assicurarsi che il tasto d accensione sia su ON Per iniziare la corsa chiudere il coperchio della centrifuga Non sono richiesti altri controlli Per terminare la rotazione premere la linguetta del coperchio posta nella parte anteriore dello strumento Ci allenter il coperchio e la rotazione terminer gradualmente ATTENZIONE Non tentare di aprire il coperchio o di rimuovere i campioni fino a che lo strumento non si arrestato Dopo che il rotore si arrestato il coperchio pu essere aperto e rester attaccato al perno Il funzionamento sicuro della centrifuga richiede che il carico del rotore sia bilanciato Un errato caricamento del rotore rappresenta una condizione di rischio e la centrifuga potrebbe essere danneggiata Provette singole in strip
9. hrten abweicht vergewissern Sie sich beim Hersteller dass die vorgeschlagene Methode das Ger t nicht besch digt Kundenservice Haben Sie Fragen zur Zentrifuge oder zu unserem Service kontaktieren Sie STARLAB oder Ihren STARLAB Handler Bitte beachten Sie Alle Warenr cksendungen m ssen grunds tzlich dekontaminiert sein Der Nachweis ber die Dekontamination ist ber eine der R cksendung beigef gte schriftliche Erk l rung zu best tigen Um Transportsch den zu vermeiden stellen Sie die ordnungsgem e Ver packung des Ger ts sicher F r Sch den am Ger t die auf unsachgem es Verpacken zur ck zuf hren sind tr gt der R cksender die Verantwortung Technische Daten Abma e 150 x 150 x 117 mm ca Angaben Leistung 115 V 60 Hz 130 mA oder 240 V 50 60 Hz 65 mA Sicherung 0 5 A 250 V F Drehzahl 6000 U min Zentrifugalkraft 2000 x G Standard Rotor 1177 x G Rotor f r Gef streifen Die STARLAB Mikrozentrifuge wird ausgeliefert mit 1 Netzkabel 2 Rotoren 1 x Standard 1 x f r PCR Gef streifen 6 Adapter zum Umbau f r die Verwendung von 0 5 ml Gef en 1 Inbusschl ssel zum Wechsel der Rotoren FRANGAIS MICROCENTRIFUGEUSE STARLAB Katalog Nummer N2631 0007 Information g n rale La centrifugeuse STARLAB est fournie avec deux rotors un standard pour les microtubes et un autre pour les tubes ou barrettes de tubes 0 2ml Le rotor standard peut centrifuger jusqu six microtubes de
10. i chiedere al produttore se il metodo prescelto non dannegger lo strumento Servizio Consumatori Contattare STARLAB o il Vostro funzionario STARLAB per qualsiasi domanda riguardante la centrifuga Non inviare l unit per riparazione prima di aver ottenuto un numero e un modulo per la decontaminazione Tutte le unit restituite dovranno essere accompagnate da un modulo di decontaminazione Assicurarsi che l unit sia ben imballata per evitare danneggiamenti qualsiasi danneggiamento sotto la responsabilit dell utilizzatore Caratteristiche Dimensioni 150 x 150 x 117mm approx Potenza 115V 60Hz 130mA or 240V 50 60Hz 65mA Fusibile 0 5A 250V F Velocit 6000 RPM RCF 2000 xG rotore standard 1177 xG rotore per strip La microcentrigufa viene fornita con 1 x cavo di alimentazione 2 x rotori uno standard uno per strip 6 x adattatori per convertire il rotore standard per usi con provette da 0 5ml 1 x chiave per sostituire i rotori NOTES STARLAB International GmbH Neuer H ltigbaum 38 22143 Hamburg Germany Tel 49 0 40 675 99 390 Fax 49 0 40 675 99 39 20 info starlab de STARLAB GmbH Neuer H ltigbaum 38 22143 Hamburg Germany Tel 49 0 40 675 99 390 Fax 49 0 40 675 99 39 20 info starlab de STARLAB UK Ltd 4 Tanners Drive Milton Keynes MK14 5NA United Kingdom Tel 44 0 1908 283800 Fax 44 0 1908 283802 infoline starlab co uk STARLAB FRANCE SARL 38 Avenue
11. ngereux l ext rieur d une hotte TOUJOURS e charger le rotor de mani re sym trique pour qu il soit quilibr Le poids de chaque tube ne doit pas d passer 3 0g e placer la centrifugeuse proche d une prise de courant e utiliser uniquement des microtubes en plastique pouvant supportant au moins 2 000 xG Nettoyage Pour nettoyer la centrifugeuse utiliser un tissu humide et un d tergent doux non corrosif pH lt 8 V rifiez que toutes les parties sont bien s ches avant d utiliser nouveau l appareil Ne pas immerger l appareil ou renverser de liquides sur celui ci Contacter le fabricant avant d utiliser toute m thode de d contamination ou d tergents diff rents de ceux indiqu s dans ce manuel pour v rifier que cela n endommagera pas l appareil Service Apr s vente Contactez STARLAB ou votre distributeur STARLAB si vous avez des questions sur cette centri fugeuse et ou ses r parations Ne pas retourner l appareil sans avoir obtenu un num ro de re tour et une fiche de d contamination Toutes les centrifugeuses doivent tre d contamin es et accompagn es d une fiche de d contamination Il convient l utilisateur de retourner l appareil dans de bonnes conditions d emballage tout dommage r sultant d un mauvais emballage lors du retour sera de la responsabilit de l utilisateur Sp cifications Dimensions 150 x 150 x 117mm approx Alimentation 115V 60Hz 130mA or 240V 50 60Hz 65mA Fusible 0 5A 250V
12. osition ON Pour commencer une centrifugation fermez le couvercle Il n y a pas d autres r glages n ces saires Pour stopper la centrifugeuse abaissez la languette situ e la base du couvercle Ceci d verrouillera le couvercle et le rotor ralentira progressivement ATTENTION Ne pas essayer d ouvrir le couvercle ou de retirer les tubes avant l arr t complet de l appareil Une fois le rotor stopp le couvercle peut tre ouvert jusqu la but e Toute centrifugation n cessite que le rotor soit quilibr Tout d s quilibre dans le chargement du rotor peut tre dangereux et endommager l appareil Les tubes individuels les barrettes et ou les adaptateurs doivent toujours tre plac s de mani re sym trique dans le rotor afin d assurer un bon quili bre Pr cautions d usage NE JAMAIS e utiliser l appareil d une autre mani re que celle d crite dans ce manuel e faire fonctionner la centrifugeuse sans que le rotor ne soit fix au moteur e remplir les tubes quand ils sont d j dans le rotor ceci pourrait abimer l appareil en cas de contact avec des liquides e utiliser la centrifugeuse avec une seule barrette de tubes e toucher le rotor avant son arr t complet e d placer l appareil pendant son fonctionnement e utiliser des solvants ou des produits inflammables proches de cet appareil ou de tout autre appareil lectrique e centrifuger des produits inflammables explosifs ou corrosifs e centrifuger des produits da
13. ren ausgeliefert Einem Standard Rotor fur Mikro Zentrifugengef e und einem Rotor f r 0 2 ml PCR Einzelgef e oder Gef streifen Der Standard Rotor hat eine Aufnahmekapazit t von bis zu sechs Mikrozentrifugengef Ben 1 5 2 0 ml Bei Benutzung des mitgelieferten Adapters ist auch die Verwendung von 0 4 0 5 ml Gef Ben m glich Der Rotor fur GefaBstreifen hat eine Aufnahmekapazit t von zwei 0 2 ml 8er PCR Gef Bstreifen oder alternativ von bis zu 16 individuellen 0 2 ml PCR EinzelgefaBen Beide Rotoren wurden f r Anwendungen entwickelt f r die nur relativ geringe Zentrifugalkrafte erforderlich sind wie zum Beispiel zur Mikrofiltration der Zelltrennung oder dem schnellen An zentrifugieren Bitte lesen Sie die Anleitung vor der Benutzung des Ger tes sorgf ltig Garantie Auf die Zentrifuge sowie die mitgelieferten Rotoren wird eine Garantie von einem Jahr gew hrt Die Garantie verf llt bei Verwendung unzul ssiger Ersatzteile bei unzul ssigen Eingriffen oder bei unsachgem er Bedienung des Rotors oder der Zentrifuge Die Garantie des Rotors ent fallt bei normalen Abnutzungserscheinungen Sch den durch radioaktive Kontamination Reini gungsmittel oder durch das Uberdrehen der Feststellschraube Sicherungen sind ebenfalls von der Garantie ausgeschlossen Austausch des Rotors Der Rotor l sst sich mit Hilfe des mitgelieferten Inbusschl ssels einfach auswechseln Suchen Sie die Feststellschraube am Rotorschaft unter dem Ro
14. s of at least 2 000 xG Cleaning Toclean the centrifuge usea damp cloth anda mild non corrosive detergent pH lt 8 After cleaning ensure all parts are dried thoroughly before attempting to operate the unit Do not immerse the centrifuge in liquid or pour liquids over it Before using any cleaning or decontamination methods except those recommended above check with the manufacturer that the proposed method will not damage the equipment Customer Services Contact STARLAB or your STARLAB distributor if you have a question about the centrifuge or the unit requires servicing Please do not send in a unit for service without first obtaining a returns number and a decontamination form All units returned must be decontaminated and accom panied by a decontamination form Ensure the unit is properly packed to avoid damage any damage resulting from improper packaging will be the responsibility of the user Specifications Dimensions 150 x 150 x 117mm approx Power 115V 60Hz 130mA or 240V 50 60Hz 65mA Fuse 0 5A 250V F Speed 6000 RPM RCF 2000 xG standard rotor 1177 xG strip rotor The STARLAB microcentrifuge is supplied with 1 x power cord 2 x rotors one standard one strip 6 x adaptors to convert the standard rotor for use with 0 5ml tubes 1 x wrench for chaning the rotors DEUTSCH STARLAB MIKROZENTRIFUGE Katalog Nummer N2631 0007 Allgemeine Informationen Die STARLAB Mikrozentrifuge wird mit zwei Roto
15. the lid lock and the rotor will slow gradually to a complete stop CAUTION Do not attempt to open the lid or remove samples until the unit has come to a complete stop After the rotor has stopped the lid may be opened so it sits back on the hinge Safe operation of the centrifuge requires that the load of the rotor be balanced Failure to load the rotor properly presents a hazardous condition and may damage the centrifuge Individual tubes strip tubes and or adapters must always be loaded symmetrically to ensure proper balance Safety Precautions NEVER e use the centrifuge in any manner not specified in these instructions e operate the centrifuge without a rotor properly attached to the shaft e fill tubes while they are in the rotor Liquid spillage may harm unit e run the centrifuge with only one strip tube in place e put hands in the rotor area unless the rotor is completely stopped e move the centrifuge while the rotor is spinning e use solvents or flammables near this or other electrical equipment e centrifuge flammable explosive or corrosive materials e centrifuge hazardous materials outside of a hood or proper containment facility ALWAYS e load the rotor symmetrically so each tube is counter balanced by another The weight of individual tubes must not exceed of 3 0g e locate the centrifuge within easy reach of an electrical outlet e use only plastic microcentrifuge tubes that are designed to withstand centrifugal force
16. torkopf L sen Sie die Feststellschraube mit Hilfe des Inbusschl ssels ziehen Sie den Rotor von der Rotorwelle und positionieren Sie den neuen Rotor auf der Rotorwelle Achten Sie darauf den Rotor nicht zu weit auf die Rotorwelle zu dr cken um die Gummimanschette an der Basis des Schaftes nicht zu quetschen Ziehen Sie die Feststellschraube mit dem Inbusschl ssel wieder fest Vorsicht Das BERDREHEN DER FESTSTELLSCHRAUBE f hrt zu Sch den am Rotor und am Rotorschaft Bedienung Bevor Sie die Zentrifuge in Betrieb nehmen stellen Sie sicher dass der Netzschalter in der ON Position steht Um einen Durchlauf zu starten schlieBen Sie den Deckel der Zentrifuge Wei tere Schritte sind nicht notwendig Um die Zentrifuge anzuhalten dr cken Sie den Hebel der Deckelverriegelung an der Vorderseite des Ger tes Das Ger t f hrt allm hlich herunter bis zum kompletten Halt Vorsicht Versuchen Sie nicht den Deckel zu ffnen oder Probengef Be aus der Zentrifuge zu entnehmen bis das Ger t vollstandig still steht Nach Anhalten des Rotors sollte der Deckel vollstandig zur ckgeklappt werden F r den sicheren Betrieb der Zentrifuge ist der Rotor gleichm ig zu beladen Unsachgem es Beladen der Zentrifuge kann Sch den am Ger t verursachen Einzelgef e Gef streifen und oder Adapter sind symmetrisch anzuordnen um ein einwandfreies Zentrifugieren zu gew hr leisten Sicherheitshinweise Niemals e das Ger t anderweitig als in