Home
ETH comfort300
Contents
1. to select an individual day ofthe 9 6 12 18 24 week all working days the weekend or the entire week example shows working days selected e Confirm with OK e Use the setting wheel to set the first time segment ex ample shows 0 00 to 6 00 e Confirm with OK e Then select the required temperature for the selected time segment example shows 17 0 C e Confirm with OK e Keep repeating this process until you have finished stor ing temperatures for the period from 0 00 to 23 59 In Auto mode the temperature can be modified at any time via the setting wheel The modified temperature will then be retained until the next program changeover 11 Weekly program Examples The energy saving controller allows you to store up to 3 heating periods 7 switching times with individual temper ature settings for each day of the week The factory set 28 ting consists of two heating phases from 6 00 until 9 00 and from 17 00 until 23 00 respectively for every single day of the week From 00 00 to 06 00 17 0 C 30 From 06 00 to 09 00 21 0 C 20 From 09 00 to 17 00 17 0 C From 17 00 to 23 00 21 0 C 1 From 23 00 to 23 59 17 0 C 0 00 6 00 12 00 18 00 23 59 o To represent the switching periods the display shows bars for every other switching interval In this exam ple no bars are shown for the interval from 0 00 to 6 00 Bars are only shown on the display for the in tervals from 6 00 to 9 00 and
2. Ausgabe Deutsch 08 2010 Dokumentation 2010 ELV Elektronik AG Alle Rechte vorbehalten 92311 V1 0 www elv com u gt LQ Tmo O D Wochentag Urlaubsfunktion ffi Manueller Betrieb Manu Au tomatikbetrieb Auto Batterie leer Symbol BET Absenk Komforttemperatur Fenster auf Sym bol f Men Taste Taste l nger als 3 Sekunden dr cken zum ffnen des Konfigurationsmen s Stellrad Einstellungen vornehmen z B Temperatur Zeit und Datumsanzeige Men punkte Funktionen Temperaturanzeige aktuelle Solltemperatur eingestellte Schaltzeitr ume im Wochenprogramm OK Taste zum Best tigen Speichern Anlernen Taste Umschalten zwischen Absenk und Kom forttemperatur 3 Der Energiespar Regler dient zum Regulieren eines gan gigen Heizk rperventils Betreiben Sie das Ger t nur in In nenr umen und vermeiden Sie den Einfluss von Feuchtig keit Staub sowie Sonnen oder W rmebestrahlung Jeder andere Einsatz als in dieser Bedienungsanleitung beschrieben ist nicht bestimmungsgem und f hrt zu Garantie und Haftungsausschluss Dies gilt auch f r Um bauten und Ver nderungen Die Ger te sind ausschlie lich f r den privaten Gebrauch gedacht Die Ger te sind keine Spielzeuge erlauben Sie Kindern nicht damit zu spielen Verpackungsmaterial nicht achtlos liegen lassen dies kann f r Kinder zu einem gef hrlichen Spielzeug werden ffnen Sie das Ger t nicht es enth lt keine dur
3. 13 Konfigurati onsmen Nach abgeschlossener Programmierung stehterneut InS im Display und die Montage Schritt 3 kann erfolgen e W hrend InS im Display steht kann bereits vor der Montage durch kurzen Druck der Taste die Anlern funktion aktiviert werden 6 Der Stellantrieb kann auf alle gangigen Heizungsventile montiert werden Ein Ablassen von Wasser oder ein Ein griff ins Heizungssystem sind dabei nicht notwendig Zu erst ist der alte Thermostatkopf zu entfernen e Thermostatkopf bis zum End anschlag nach links drehen A e Befestigung des Thermos tatkopfes l sen B e Thermostatkopf vom Ventil abziehen C Der beiliegende St tzring dient bei kleinen Ventilanschl ssen zur stabileren Befestigung des Energiespar Reglers e Stecken Sie den St tzring auf den Ventilanschluss D auf Ist der Ventilanschluss so gro dass der St tzring nicht auf gesteckt werden kann ist die Stabilit t ausreichend und der St tzring wird nicht ben tigt F r einige Ventile ist ein Ad apter zu verwenden Adapter f r Danfoss Ventile RA RAV RAVL liegen bei Details bitte der Adapter bersicht siehe 27 entnehmen e Der Adapter ist vollst ndig auf das Ventil aufzurasten Um die Adapter RA und RAV weit genug auseinanderbiegen zu k nnen muss ggf ein Schrau bendreher verwendet werden e Beim RAV Adapter ist die mitgelieferte Verl ngerung auf den Ventilst el zu s
4. Betriebs Modi 10 10 Mit kurzem Druck der Men Taste kann zwischen den fol genden 3 Betriebsmodi gewechselt werden die Betriebs Modi sind erst nach der Installation Schritt 3 ausw hlbar e Urlaubsfunktion p Einstellen einer Temperatur die bis zu einem fixen Zeitpunkt gehalten werden soll e Manu Manueller Betrieb die Temperatur wird manuell ber das Stellrad eingestellt e Auto Wochenprogramm automatische Temperaturre gelung gem hinterlegtem Wochenprogramm 13 Konfigurationsmen Im Konfigurationsmen lassen sich Einstellungen ndern Das Men l sst sich ber einen langen Tastendruck l nger als 3 Sekunden der Men Taste aufrufen e Pro Einstellung des Wochenprogramms siehe Abschnitt 10 Wochenprogramm einstellen e dAt ndern von Uhrzeit und Datum e POS Abfrage der aktuellen Position des Stellantriebs e dSt Die automatische Umschaltung zwischen Sommer und Winterzeit kann deaktiviert werden e AEr Fenster auf Temperatur und Zeit f r die automati sche Temperaturabsenkung beim L ften einstellen 11 e tOF Offset Temperatur einstellen e rES Werkseinstellungen wieder herstellen e UnL Ablernen aller angelernten Funkkomponenten Men punkte werden mit dem Stellrad ausgew hlt und mit OK best tigt Ein erneuter Druck der Men Taste f hrt zur vorherigen Ebene zur ck Nach 65 Sekunden Inaktivit t schlie t sich das Men automatisch Im Normalbetrieb werden Wochentag Uh
5. einge stellt werden Werden z B 18 C anstatt eingestellter 20 C gemessen ist ein Offset von 2 0 C einzustellen e Die Men Taste l nger als 3 Sekunden dr cken e Mit dem Stellrad den Men punkt tOF ausw hlen e Mit OK Taste best tigen e Die Temperatur mittels des Stellrads ver ndern e Best tigung erfolgt durch die OK Taste Der Auslieferungszustand des Stellantriebs kann manuell wieder hergestellt werden Dabei gehen alle manuell vor genommenen Einstellungen verloren e Die Men Taste l nger als 3 Sekunden dr cken e Mit dem Stellrad den Men punkt rES ausw hlen e Mit OK Taste best tigen e Es erscheint ACC im Display mit OK best tigen 26 Fehlerbehebung und Wartung Fehlercode im Display Problem Behebung Batteriesymbol Batterieleistung Batterien zu gering austauschen A P Installation pr fen F1 Ventilantrieb Heizungsventil schwerg ngig berpr fen A Befestigung F2 Pe des Stellantriebs g berpr fen F3 Stellbereich Heizungsventil zu klein berpr fen Bereits 1 Wand F4 thermostat an gelernt N Gerate ablernen Bereits 4 Funk F5 komponenten angelernt o Einmal w chentlich am Samstag um 12 00 f hrt der Stellantrieb zum Schutz vor Ventilverkalkung eine Entkalkungsfahrt durch Dabei erscheint CAL im Display 17 Hersteller Abbildung Adapter Heimeier MNG Junkers Landis amp Gyr Duodyr Honeywell Brau
6. from 17 00 to 23 00 If a room also needs to be heated at around noon the cor responding program might look like this Monday to Sunday From 00 00 to 06 00 16 0 C From 06 00 to 09 00 22 0 C From 09 00 to 12 00 17 0 C From 12 00 to 14 00 20 0 C From 14 00 to 17 30 17 0 C From 17 30 to 23 30 21 0 C bid From 23 30 to 23 59 16 0 C If you have a home office and only want it to be heated during the day on working days you can program the fol lowing times Monday to Friday 5 0 00 6 00 12 00 10 00 23 59 From 00 00 to 08 30 17 0 C a From 08 30 to 17 00 21 0 C 0 06 6 50 12 60 1800 Ze From 17 00 to 23 59 17 0 C Saturday and Sunday ls From 00 00 to 23 59 15 0 C 0 00 6 00 12 00 18 00 23 69 29 12 Operating modes To switch between the 3 operating modes described be low press the menu button briefly these operating modes can only be selected following installation Step 3 e Holiday function pi Set a temperature that is to be maintained until a fixed point in time e Manu Manual operation The temperature is set manu ally using the setting wheel e Auto Weekly program The temperature is control led automatically in accordance with the stored weekly program 13 Configuration menu The configuration menu can be used to modify settings To access this menu press and hold down the menu button for more than 3 seconds e Pro For setting the weekly program see Section 10
7. kann das Ventil geschlossen werden Nur bei Frostgefahr wird das Ventil ge ffnet Der Verkalkungsschutz wird weiter durchgef hrt Funkbefehle von Fensterkontakt oder Fernbedienung wer den nicht mehr ausgef hrt e Um den Frostschutzbetrieb zu aktivieren ist das Stell rad im manuellen Betrieb Manu so lange nach links zu drehen bis im Display OFF erscheint e Zum Beenden ist der manuelle Betrieb Manu zu verlas sen oder das Stellrad nach rechts zu drehen 23 Fenster auf Funktion Der Stellantrieb regelt beim L ften die Temperatur um Heizkosten zu sparen W hrenddessen wird im Display das Fenster auf Symbol Bd angezeigt Ohne Fensterkontakt Der Stellantrieb erkennt eine stark absinkende Temperatur durchs L ften automatisch Fens ter auf Temperatur und Zeit sind einstellbar Mit angelerntem Fensterkontakt Die Temperatur wird nur w hrend der Fenster ffnung heruntergeregelt Die Fenster auf Temperatur ist einstellbar e Die Men Taste l nger als 3 Sekunden dr cken e Mit dem Stellrad den Men punkt AEr ausw hlen e Mit OK Taste best tigen 15 e Temperatur Zeit lassen sich mit dem Stellrad einstellen Abschlie end mit OK Taste best tigen e Ohne angelernten Fensterkontakt l sst sich diese Funk tion durch Zeitauswahl 0 deaktivieren Da die Temperatur am Heizk rper gemessen wird kann es woanders im Raum k lter oder w rmer sein Um dies an zugleichen kann ein Temperatur Offset von 3 5 C
8. stability is already sufficient and the sup port ring is not required An adapter will need to be used in the case of certain valves Adapters for Danfoss valves RA RAV RAVL are included in the scope of delivery For de tails please refer to the adapter overview see 27 e The adapter must be fully latched onto the valve You may find it necessary to use a screwdriver to bend the RA and RAV adapters far enough apart e In the case of the RAV adapter the extension supplied must be attached to the valve tappet e The RA and RAV adapters must in addition be secured by means of the bolt and nut supplied The energy saving controller can only be installed if InS is showing on the display Following installation the actuator will perform an adjustment run so that it can adapt to the valve During this process AdA will be displayed e Place the actuator on the valve e Tighten the union nut e InS will appear on the display press the OK button e The actuator will perform an adjustment run AdA will appear on the display operation not possible e After that the actuator will be ready for operation Auto mode G If the adjustment run was initiated prior to installa tion or if an error message will be displayed F1 F2 F3 press OK to move the motor back to the InS position 26 The anti theft tamper protec tion device prevents the radio energy saving controlle
9. 00 D 26787 Leer 40
10. Bedienungsanleitung 9 Operating Manual ETH comfort300 Funk Elektronik Thermostat f r Heizk rper S 2 Radio electronic thermostat for radiators p 20 ELV Elektronik AG PF 1000 D 26787 Leer ar SOONDARONS Ti 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Inhaltsverzeichnis Bedienung und Display BestimmungsgemaBer Einsatz Sicherheitshinweis Entsorgungshinweis Allgemeine Funktion Schritt 1 Batterien einlegen wechseln Schritt 2 Datum und Uhrzeit einstellen Schritt 3 Energiespar Regler montieren Schritt 4 Diebstahl Sabotageschutz montiere Wochenprogramm einstellen Wochenprogramm Beispiele Betriebsmodi Konfigurationsmen Display Inhalt im Normalbetrieb Anlernen von Funkkomponenten Ablernen von Funkkomponenten Betrieb mit Wandthermostat Urlaubsfunktion einstellen Komfort und Absenktemperatur Kindersicherung Bediensperre Heizpause einstellen Frostschutzbetrieb einstellen Fenster auf Funktion Offset Temperatur einstellen Werkseinstellungen wieder herstellen 16 Fehlerbehebung und Wartung 17 Adapter bersicht 18 Hinweise zum Funkbetrieb Technische Eigenschaften Lesen Sie diese Anleitung sorgf ltig um das Ger t in Betrieb zu neh men Bewahren Sie die Anleitung zum sp teren Nachschlagen auf 1
11. Linearer Hub 4 2 mm Federkraft max 80 N Technische nderungen die zur Verbesserung dienen sind vorbehalten 19 Table of contents Operation and display Intended use Safety instructions Instructions for disposal General function Step 1 Inserting replacing the batteries Step 2 Setting the date and time of day Step 3 Installing the energy saving controller Step 4 Mounting the anti theft tamper protection device 10 Setting the weekly program 11 Weekly program Examples 12 Operating modes 30 13 Configuration menu 14 Display content during normal operation 15 Teaching in wireless components 31 16 Teaching out wireless components 17 Operation with a wall thermostat 18 Setting the holiday function 19 Comfort and set back tempera 20 Child proof lock Operating inhibit 21 Setting the heating break 34 22 Setting frost protection mode PONDARWN 23 Window open function 35 24 Setting the offset temperature 35 25 Restoring the factory settings 36 26 Troubleshooting and maintenance 27 Adapter overview 28 Information about radio operation 29 Technical properties Please read this manual carefully in order to help you putthe device into operation Keep the manual handy so you can refer to it at a later date Issue 1 English 08 2010 Documentation 2010 ELV Elektronik AG All rig
12. R B M Tiemme Jaga Included Danfoss RA in scope of supply Included Danfoss RAV in scope of supply Included Danfoss RAVL in scope of supply Other adapters available as accessories 38 Radio transmission is performed on anon exclusive trans mission path which means that there is a possibility of interference occurring Switching operations electric motors or faulty electric de vices are some of the reasons why interference may oc cur The range of transmission within buildings can deviate greatly from open air distances Besides the transmitting power and the reception characteristics of the receiver environmental influences such as humidity and local struc tures also play an important role ELV Elektronik AG hereby declares that this device con forms with the essential requirements and other relevant regulations of Directive 1999 5 EC The full declaration of conformity is provided at www elv de Supply voltage 3V Max current consumption 100 mA Batteries 2x LR14 batteries Baby C Battery life Approx 5 years Display LC display Receiver frequency 868 3 MHz Housing dimensions 63 x 70 x 99 mm W x H x D Connection M30 x 1 5 Ambient temperature 5 to 55 C Max surface temperature 90 C of radiator Linear travel 4 2mm Spring force max 80 N We reserve the right to make any technical changes that constitute an improvement to the device 39 ELV Elektronik AG PF 10
13. Setting the weekly program e dAt For modifying the time of day and date e POS For querying the actuator s current position e dSt Automatic switchover at the start or end of daylight saving time can be deactivated e AEr Forsetting the window open temperature andtime so that the temperature is automatically reduced in the event of ventilation e tOF For setting the offset temperature e rES For restoring the factory settings e UnL For teaching out all taught in wireless components Use the setting wheel to select menu items and the OK but ton to confirm your choice Press the menu button again to return to the previous level After 65 seconds without any thing happening the menu will close automatically 30 During normal operation the following are dis played day of the week time of day date op erating mode temperature setting and switch ing periods z The bars indicating the weekly program s switching peri ods are shown for every other time interval For an exam ple please refer to 11 Weekly program Examples The actuator supports the teaching in of up to 4 system components e g remote control and window contact plus 1 wall thermostat e Press and hold down the OK button for more than 3 seconds e Theremainingteach intime willbe displayed 30 seconds e The device being taught in now needs to send a wireless signal e g press button on remote control e The display will then sw
14. ch den Anwender zu wartenden Teile Im Fehler fall schicken Sie das Ger t an den Service Ger t nicht im Hausm ll entsorgen Elektronische Ger te sind entsprechend der Richtlinie ber Elektro und Elektronik Altger te ber die rtlichen Sammelstellen f r Elektronik Altger te zu entsorgen 1 Das CE Zeichen ist ein Freiverkehrszeichen das C sich ausschlie lich an die Beh rden wendet und keine Zusicherung von Eigenschaften beinhaltet gt 5 Allgemeine Funktion Der Energiespar Regler f r Heizk rper regelt zeitgesteuert die Raumtemperatur Der Stellantrieb bewegt ein Ventil um den Warmezustrom am Heizk rper zu steuern Der Reg ler passt auf alle g ngigen Heizk rperventile Das gro e beleuchtete Display dient zur komfortablen Bedienung ber einen Funkempf nger kann das Ger t Befehle von angelernten Systemkomponenten empfangen Durch die Verwendung von Baby Zellen wird eine Wartung nahezu unn tig Der Sabotage und Diebstahlschutz verhindert ein unbefugtes Demontieren Die Montage erfolgt in 4 einfachen Schritten 6 Schritt 1 Batterien einlegen wechseln e Batteriefachdeckel abziehen e 2 neue LR14 Batterien Baby C pol ungsrichtig in das Batteriefach einlegen e Batteriefachdeckel wieder aufsetzen und einrasten Die Lebensdauer neuer Alkali Batterien betr gt ca f nf Jahre Ein Batteriesymbol amp weist darauf hin dass die Batteri en auszutauschen sind Vor dem Wechseln der Batterien m
15. entries are still being made e If InS is displayed with a rotating symbol this indicates that the motor is still moving back Once the device is ready for the actuator to be installed on the oe just InS will appear on the display e The weekly program and other settings can be cus tomised prior to installation To do this press the menu button when InS is shown on the display For further details please see 13 Configuration menu e Once programming is complete InS will reappear on the display and installation Step 3 can commence e When InS is visible on the display you can activate the teach in function prior to installation by pressing the button briefly 8 Step 3 Installing the energy saving controller The actuator can be installed on all standard heating valves There is no need to drain away water or fiddle around with the heating system before doing this First you need to remove the old thermostat dial e Turn the thermostat dial anti clockwise as far as it will go A e Release the thermal ring of the thermostat B e Remove the thermostat from the valve C The support ring supplied helps to fasten the energy saving con troller in amore stable position if the relevant valve connections are only small e Attach the support ring to the valve connection D If the valve connection is too large to attach the support ring to it the
16. ht way round Pa j e Reattachthe battery compartment cover VG lt and click into place KN New alkaline batteries have a life of ap proximately five years A battery symbol will in dicate when the batteries need to be replaced Before changing the batteries you must remove the anti theft tamper protection device After removing the old batter ies please wait approximately 1 minute before inserting the new ones This device does not support operation with rechargeable batteries N Never recharge standard batteries Doing so will present a risk of explosion N Do not throw the batteries into a fire Do not short circuit batteries X N 23 LKX Used batteries should not be disposed of es 9 with regular domestic waste Instead they Ke should be taken to your local battery dis posal point 7 Step 2 Setting the date and time of day The firmware version number will be displayed briefly once you have inserted replaced the batteries and then you will be automatically prompted to set the date and time of day e Use the setting wheel C o set the year B Confirm with OK D e Use the setting wheel C o set the month B Confirm with OK D Use the setting wheel C o set the day B Confirm with OK D Use the setting wheel C o set the hour A Confirm with OK D Use the setting wheel C o set the minute A e Confirm with OK D The motor will start moving back the control pin while the
17. hts reserved 98265 V1 0 www elv com 20 u gt O TMS QO D ANNAN ADE Day of the week Holiday function fi manual operation Manu au tomatic operation Auto battery empty symbol BT set back comfort temperature E window open symbol f Menu button Press and hold down the button for more than 3 seconds to open the configuration menu Setting wheel Formaking adjustments e g temperature Time and date indicator menu items functions Current temperature setting Switching periods set within weekly program OK button For confirming saving teaching in button For switching between set back and com fort temperatures 21 The energy saving controller has been designed for the purpose of controlling a standard heating appliance val ve The device may only be operated indoors and must be protected from the effects of damp and dust as well as solar radiation and sources of radiant heat Using the device for a purpose or in a manner other than that described in this operating manual constitutes a breach of the intended use and shall invalidate the war ranty and any liability claims The same shall apply in the event of any conversion or modification work The devices are intended exclusively for domestic use The devices concerned are not intended for children and must not be used as toys Do not leave packaging materi al lying around as children might be tempted to p
18. itch to the normal view Once this has been done the actuator will respond to wire less commands from taught in devices Whenever the ac tuator receives a signal from a window contact or remote control the display will light up briefly 31 Components that have been taught in on the actuator can be taught out again using the UnL Unlearn func tion All wireless components are taught out at once with this function e Press and hold down the menu button for more than 3 seconds e Use the setting wheel to select the UnL menu item e Confirm with OK e ACC will appear on the display press OK to confirm If the actuator is going to be operated in conjunction with a wall thermostat this thermostat will need to be taught in see section 15 Once it has been taught in ECF will ap pear on the display No further settings can then be made on the actuator and it will no longer respond to taught in remote controls or window contacts If no wireless signal is received from the wall thermostat for a period of 60 minutes the actuator will exit ECF mode It will then assume control of the temperature which it will continue to regulate in accordance with the weekly pro gram until the next wireless signal is received To teach out a wall thermostat you must reinsert the bat teries in the actuator wait for approx 1 minute Once you have entered the date and time of day you can use the menu b
19. kmann kein Oventrop Schl sser Adapter Simplex Valf Sanayii erforderlich Mertik Maxitrol Watts Wingenroth Wiroflex R B M Tiemme Jaga Danfoss RA iegt bei Danfoss RAV iegt bei Danfoss RAVL iegt bei Weitere Adapter sind als Zubeh r erh ltlich 18 28 Hinweise zum Funkbetrieb Die Funk Ubertragung wird auf einem nicht exklusiven Ubertragungsweg realisiert weshalb St rungen nicht ausgeschlossen werden k nnen St reinfl sse k nnen u a durch Schaltvorg nge Elektro motoren oder auch defekte Elektroger te hervorgerufen werden Die Reichweite in Geb uden kann stark von der im Freifeld abweichen Au er der Sendeleistung und den Empfangseigenschaften der Empf nger spielen Umwelt einfl sse wie Luftfeuchtigkeit neben baulichen Gegeben heiten eine wichtige Rolle Hiermit erkl rt die ELV Elektronik AG dass sich dieses Ger t in bereinstimmung mit den grundlegenden An forderungen und den anderen relevanten Vorschriften der Richtlinie 1999 5 EG befindet Die vollst ndige Konformi t tserkl rung finden Sie unter www elv de 29 Technische Eigenschaften Versorgungsspannung 3V Max Stromaufnahme 100 mA Batterien 2x LR14 Batterie Baby C Batterielebensdauer ca 5 Jahre Display LC Display Empfangerfrequenz 868 3 MHz Gehauseabmessung 63 x 70 x 99 mm BxHxT Anschluss M30 x 1 5 Umgebungstemperatur 5 bis 55 C Max Oberflachentemperatur 90 C am Heizk rper
20. lay with it which is extremely dangerous Do not open the device it does not contain any components that need to be ser viced by the user In the event of an error please return the device to our service department Do not dispose of the device with regular domestic waste Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with local directives governing waste electrical and electronic equipment pa The CE sign is a free trade sign addressed exclu C sively to the authorities and does not warrant any properties 22 5 General function This energy saving controller for radiators can be used to control room temperature on the basis of time The ac tuator moves a valve thereby allowing the amount of heat flowing to the heating appliance to be controlled The controller is compatible with all standard heating appliance valves The large illuminated display ensures user friendly operation A wireless receiver allows the device to receive commands from taught in system com ponents The use of BABY cells means that the unit is practically maintenance free The anti tamper and theft protection device prevents unauthorised dismantling Installation can be achieved in 4 easy steps 6 Step 1 Inserting replacing the batteries e Remove the battery compartment cover N e Insert2 newLR14 batteries Baby C into RR the battery compartment ensuring they A are the rig
21. programm Beispiele Mit dem Energiespar Regler k nnen f r jeden Wochentag bis zu 3 Heizzeiten 7 Schaltzeitpunkte mit individueller Temperaturvorgabe hinterlegt werden Werkseitig sind zwei Heizphasen von 6 00 bis 9 00 Uhr und von 17 00 bis 23 00 Uhr f r alle Wochentage gleich hinterlegt ab 00 00 bis 06 00 17 0 C 30 ab 06 00 bis 09 00 21 0 C 20 ab 09 00 bis 17 00 17 0 C ab 17 00 bis 23 00 21 0 C ab 23 00 bis 23 59 17 0 C 6 00 6 00 12 00 18 00 23 59 oO Im Display werden Balken f r Zeitschaltr ume f r je des zweite Zeitintervall angezeigt Bei diesem Bei spiel werden keine Balken f r das Intervall 0 00 bis 6 00 eingeblendet Nur f r die Intervalle 6 00 bis 9 00 und 17 00 bis 23 00 erscheinen Balken im Display Soll ein Raum auch zur Mittagszeit beheizt werden kann eine Programmierung wie folgt aussehen 10 Montag bis Sonntag ab 00 00 bis 06 00 16 0 C ab 06 00 bis 09 00 22 0 C ab 09 00 bis 12 00 17 0 C 30 ab 12 00 bis 14 00 20 0 C ab 14 00 bis 17 30 17 0 C ab 17 30 bis 23 30 21 0 C ab 23 30 bis 23 59 16 0 C 0 00 6 00 12 00 10 00 23 59 10 Haben Sie zu Hause ein B ro und m chten dies nur tags ber an Werktagen heizen k nnten Sie die folgenden Zei ten programmieren zon Montag bis Freitag ab 00 00 bis 08 30 17 0 C ab 08 30 bis 17 00 21 0 C 0 00 E00 12 00 18 00 23 59 ab 17 00 bis 23 59 17 0 C Samstag bis Sonntag ab 00 00 bis 23 59 15 0 C 0 00 6 06 12 00 18 00 23 69 12
22. r zeit Datum Betriebsmodus Soll Temperatur und Schaltzeitr ume angezeigt Die Balken f r Schaltzeitr ume des Wochen oy programms werden fir jedes zweite Zeitintervall angezeigt Beispiel unter 11 Wochenprogramm Beispiele Am Stellantrieb k nnen bis zu 4 Systemkomponenten wie Fernbedienung und Fensterkontakt sowie 1 Wandthermo stat angelernt werden e Dr cken Sie die OK Taste l nger als 3 Sekunden e Es wird die verbleibende Anlernzeit angezeigt 30 Sek e Jetzt muss das anzulernende Ger t ein Funksignal sen den z B Tastendruck einer Fernbedienung e Danach wechselt das Display zur Normalansicht Der Stellantrieb reagiert danach auf Funkbefehle ange lernter Ger te Beim Empfang von Fensterkontakt oder Fernbedienung leuchtet das Display kurz auf Am Stellantrieb angelernte Komponenten k nnen mit der Funktion Unlearn UnL wieder abgelernt werden Dabei werden alle Funkkomponenten gleichzeitig abgelernt 12 e Die Men Taste l nger als 3 Sekunden dr cken e Mit dem Stellrad den Men punkt UnL ausw hlen e Mit OK Taste best tigen e Es erscheint ACC im Display mit OK best tigen 17 Betrieb mit Wandthermostat Soll der Stellantrieb zusammen mit einem Wandthermos tat betrieben werden muss dieser angelernt werden sie he Abschnitt 15 Nach erfolgreichem Anlernen erscheint ECF im Display am Stellantrieb kann keine Einstellung mehr vorgenommen werden und er
23. r and its batteries from simply being removed and stolen e Push the anti tamper protec tion device into the guide from below until it engages E The battery compartment can now not be opened e Attach the upper shell F and lower shell G to the union nut until they en E gage The bars H on the shells must slot into the flange spaces e Insert the M3 hexagon socket head screws I and fas ten them on the other side with nuts Q The upper shell and lower shell can be mounted in any position The purpose of the lower shell which is slightly longer is to prevent the radio energy saving controller from any attempts to remove it by unauthorised persons by twisting it off It is long enough to make contact with the valve when the connection is rotated The lower shell should be attached in such a way that it can as respond as quickly as possible to any attempts to twist off the controller 27 10 Setting the weekly program The weekly program allows you to set up to 3 separate heating periods 7 switching times for each day of the week Programming is performed in relation to the se lected days for which temperatures must be stored for a period from 00 00 to 23 59 e Press and hold down the menu f wo Tu We m Fr button for more than 3 seconds if e Pro will appear on the display on oan e Confirm with OK c e dAy will appear on the display I The setting wheel can be used
24. reagiert nicht mehr auf angelernte Fernbedienungen oder Fensterkontakte Wird f r 60 Min kein Funksignal vom Wandthermostat empfangen verl sst der Stellantrieb den ECF Modus Bis zum n chsten Empfang regelt er autark gem Wo chenprogramm weiter Soll ein Wandthermostat abgelernt werden m ssen Sie die Batterien im Stellantrieb neu einlegen ca 1 Minute warten Nach Eingabe von Datum und Uhrzeit kann vor Ausl sen der Adaptierfahrt ber die Men Taste das Ab lernen wie in Abschnitt 16 erkl rt durchgef hrt werden 18 Urlaubsfunktion einstellen Wenn w hrend eines Urlaubs oder einer Party f r einen be stimmten Zeitraum eine feste Temperatur gehalten werden soll kann die Urlaubsfunktion genutzt werden e Die Men Taste ist so oft kurz zu dr cken bis im Display das Koffersymbol gg erscheint e Uber das Stellrad ist die Uhrzeit einzustellen bis zu der die Temperatur gehalten werden soll e Best tigung durch die OK Taste e Mit dem Stellrad ist danach das Datum einzustellen e Best tigung durch die OK Taste 13 e Mit dem Stellrad die Temperatur einstellen mit OK be statigen Die Anzeige blinkt zur Bestatigung Die eingestellte Temperatur bleibt bis zum vorgegebenen Zeitpunkt bestehen Danach geht der Stellantrieb in den Auto Modus Funkbefehle von Fensterkontakt und Fern bedienung werden weiterhin ausgef hrt Die Taste Komfort Absenktemperatur dient zur kom fortablen und einfachen Um
25. rt werden Die etwas langere Unterschale hat die Aufgabe das Abdrehen des Funk Energiespar Reglers zu verhin dern Sie ist so lang dass sie beim Drehen des An schlusses gegen das Ventil st t Die Unterschale sollte so angebracht sein dass sie bei einem versuchten Losdrehen des Reglers m g lichst bald blockiert 10 Wochenprogramm einstellen Im Wochenprogramm lassen sich f r jeden Wochentag se parat bis zu 3 Heizphasen 7 Schaltzeitpunkte einstellen Die Programmierung erfolgt f r die ausgew hlten Tage wobei f r einen Zeitraum von 00 00 bis 23 59 Temperaturen hinterlegt werden m ssen e Men Taste l nger als 3 Sekun den dr cken e Im Display erscheint Pro e Mit OK Taste best tigen e Im Display erscheint dAy Mit dem Stellrad sind ein einzel ner Wochentag alle Werktage das Wochenende oder die gesamte Woche ausw hlbar Bsp Werktage e Mit OK Taste best tigen e Mit dem Stellrad den ersten Zeitabschnitt einstellen Bsp 0 00 bis 6 00 e Mit OK best tigen e Danach ist f r den ausgew hlten Zeitabschnitt die ge w nschte Temperatur auszuw hlen Bsp 17 0 C e Mit OK best tigen e Dieser Vorgang ist zu wiederholen bis f r den Zeitraum von 0 00 bis 23 59 Temperaturen hinterlegt sind Im Auto Modus kann die Temperatur ber das Stellrad je derzeit ver ndert werden Die ge nderte Temperatur bleibt dann bis zum n chsten Programmwechsel erhalten 11 Wochen
26. schaltung zwischen diesen beiden Temperaturen Werkseitig liegen diese bei 21 0 C und 17 0 C Sie k nnen wie folgt angepasst werden e Die Komfort Absenktaste lange gedr ckt halten e Im Display erscheinen das Sonnensymbol 3 und die aktuelle Komforttemperatur e Temperatur mit Stellrad ver ndern mit OK best tigen e Es erscheinen Mondsymbol und Absenktempe ratur e Temperatur mit Stellrad ver ndern mit OK best tigen Auch im Auto Modus kann die Temperatur ber die Tas te jederzeit ge ndert werden Diese bleibt dann bis zum n chsten Schaltzeitpunkt des Programms erhalten Die Bedienung kann gesperrt werden e Umdie Bediensperre zu aktivieren deaktivieren sind die Tasten Menu und gleichzeitig kurz zu dr cken e Nach Aktivierung erscheint LOC im Display e Zur Deaktivierung beide Tasten erneut dr cken Ist die Heizung im Sommer abgeschaltet k nnen die Bat terien geschont werden Dazu wird das Ventil ganz ge 14 ffnet Der Verkalkungsschutz wird weiter durchgef hrt Funkbefehle von Fensterkontakt oder Fernbedienung wer den nicht mehr ausgef hrt e Um die Heizpause zu aktivieren ist das Stellrad im ma nuellen Betrieb Manu so lange nach rechts zu drehen bis im Display On erscheint e Zum Beenden ist der manuelle Betrieb Manu zu verlas sen oder das Stellrad nach links zu drehen 22 Frostschutzbetrieb einstellen Wenn der Raum nicht geheizt werden soll
27. tecken e Die Adapter RA und RAV sind zus tzlich mit der mit gelieferten Schraube und Mutter zu befestigen Damit der Energiespar Regler montiert werden kann muss im Display InS stehen Nach der Montage f hrt der Stell antrieb zur Anpassung ans Ventil eine Adaptierfahrt durch W hrenddessen wird AdA angezeigt e Stellantrieb auf Ventil setzen e Uberwurfmutter festziehen e Im Display steht InS OK Taste dr cken e Der Stellantrieb f hrt eine Adaptierfahrt durch im Display erscheint AdA keine Bedienung m glich e Danach ist der Stellantrieb betriebsbereit Auto Modus o Wurde die Adaptierfahrt vor der Montage eingeleitet bzw wird eine Fehlermeldung F1 F2 F3 angezeigt dr cken Sie OK und der Motor f hrt zur ck zur Po sition InS 9 Schritt 4 Diebstahl Sabotageschutz montieren Der Diebstahl Sabotageschutz verhindert das einfache Abbauen und Stehlen des Funk Energie spar Reglers und der Batterien e Sabotageschutz von unten in die F hrung schieben und ein rasten lassen E Hiermit wird das ffnen des Batteriefachs verhindert e Ober F und Unterschale G auf die berwurfmutter stecken und einrasten lassen Die Stege H der Schalen m ssen in die 8 Zwischenr ume des Flansches greifen e M3 Innensechskantschrauben einf hren I und an der Gegenseite mit Muttern befestigen Die Ober und Unterschale k nnen in beliebigen Po ea sitionen montie
28. that an offset of 2 0 C needs to be configured e Press and hold down the menu button for more than 3 seconds e Use the setting wheel to select the tOF menu item e Confirm with OK e Use the setting wheel to modify the temperature e Press the OK button to confirm You can reset the actuator to its initial state manually This will clear all the settings that have been made manually e Press and hold down the menu button for more than 3 seconds e Use the setting wheel to select the rES menu item e Confirm with OK e ACC will appear on the display press OK to confirm 36 26 Troubleshooting and maintenance Error code on display Problem Remedy Battery symbol Battery power E too low Replace batteries Check installation F1 Valve actuator inspect heating sluggish Valve ar Check F2 le an actuator g fastening E3 Adjusting range Check heating too small valve 1 wall thermo F4 stat already taught in Teach out devices 4 wireless com F5 ponents already taught in At 12 00 every Saturday the actuator performs a weekly descaling function to prevent valve calcifica tion CAL will appear on the display 37 Manufacturer Figure Adapter Heimeier MNG Junkers Landis amp Gyr Duodyr Honeywell Braukmann Oventrop Schl sser Noadapier Simplex Valf Sanayii aq Mertik Maxitrol Watts Wingenroth Wiroflex
29. ticlockwise during manual operation Manu until OFF appears on the display e To terminate frost protection mode quit manual opera tion Manu or turn the setting wheel clockwise 23 Window open function If the room is being ventilated the actuator controls the temperature to save on heating costs While this func tion is active the window open symbol appears on the display Without window contact The actuator will automati cally detect a significant drop in temperature due to ven tilation You can set your own window open tempera ture and time With taught in window contact The temperature will only be reduced during the time that the window is left open You can set your own window open temperature e Press and hold down the menu button for more than 3 seconds e Use the setting wheel to select the AEr menu item e Confirm with OK e Use the setting wheel to set the temperature time Then press OK to confirm e Without a taught in window contact this function can be deactivated by selecting a time of 0 24 Setting the offset temperature The temperature is measured at the heating appliance it self with the result that other parts of the room may be warmer or colder than this To allow for this you can set a temperature offset of 3 5 C If for example a temper ature of 18 C is measured somewhere within the room 35 instead of the 20 C set it means
30. ture press OK to confirm e The moon symbol will appear together with the set back temperature e Use the setting wheel to modify the temperature press OK to confirm 33 The temperature can even be modified in Auto mode at any time by using this button The new setting will be retained until the program s next switching time Operation can be inhibited e To activate deactivate the operating inhibit briefly press the Menu and x buttons at the same time e Once the function is active LOC will appear on the display e To deactivate the function press both buttons again If the heating is being switched off for the summer you can save battery power This involves opening the valve up fully Limescale protection measures remain in place Wireless commands from the window contact or remote control will no longer be executed e To activate the heating break turn the setting wheel clockwise during manual operation Manu until On appears on the display e To terminate the heating break quit manual operation Manu or turn the setting wheel anticlockwise If you do not want the room to be heated the valve can be closed It will only be opened again if there is a risk of freezing due to frost Limescale protection measures re main in place Wireless commands from the window con tact or remote control will no longer be executed e To activate frost protection mode turn the setting wheel an
31. uss der Diebstahl Sabotageschutz demontiert werden Nach Entnahme der Batterien sollte bis zum Einlegen der neuen Batterien ca 1 Minute gewartet werden Ein Betrieb mit Akkus ist nicht m glich r Normale Batterien d rfen niemals aufgeladen werden Es besteht Explosionsgefahr Batterien nicht ins Feuer werfen nn nicht kurzschlie en Verbrauchte Batterien geh ren nicht in Lo den Hausm ll Entsorgen Sie diese in Ihrer rtlichen Batteriesammelstelle 7 Schritt 2 Datum und Uhrzeit einstellen Wenn Batterien eingelegt oder ausgetauscht werden wird nach kurzer Anzeige der Firmware Versionsnummer auto matisch Datum und Uhrzeit abgefragt AB e Jahr B mit Stellrad C einstellen e Mit OK D best tigen e Monat B mit Stellrad C einstellen e Mit OK D best tigen e Tag B mit Stellrad C einstellen e Mit OK D best tigen e Stunde A mit Stellrad C einstellen e Mit OK D best tigen e Minute A mit Stellrad C einstellen e Mit OK D best tigen C D W hrend der Eingaben f hrt der Motor den Steuerstift bereits zur ck e Die Anzeige InS mit drehendem weist darauf hin dass der Motor noch zur ckf hrt Sobald der Stell antrieb am Ventil montiert werden kann steht nur InS im Display Das Wochenprogramm und andere Einstellungen k nnenvor der Montage angepasst werden Dr cken Sie dazu die Men Taste w hrend in der Anzeige InS steht Mehr Details finden Sie unter
32. utton before the adjustment run is initiated to per form the teach out process as described in section 16 18 Setting the holiday function If you want a fixed temperature to be maintained for a set period of time while you are on holiday or during a party you can make use of the Holiday function e Press and release the menu button repeatedly until the suitcase symbol fi appears on the display e Use the setting wheel to set the end of the time period during which the temperature is to be maintained e Press the OK button to confirm e Then use the setting wheel to set the date e Press the OK button to confirm e Use the setting wheel to set the temperature press OK to confirm The display will flash to confirm your settings The set temperature will remain in force until the speci fied time After that the actuator will adopt Auto mode Wireless commands from the window contact and remote control will continue to be executed 19 Comfort and set back temperatures The comfort set back temperature button provides an easy and convenient way of switching between these two temperatures The factory settings are 21 0 C and 17 0 C respectively To adapt them proceed as follows e Pressandholddownthecomfort set backtemperaturebut ton s for more than 3 seconds e The sun symbol gt will appear on the display along with the current comfort temperature e Use the setting wheel to modify the tempera