Home

410471_D_Benutzerhandbuch Saunaofen Nordex Next

image

Contents

1. Reflexionsplatte 13 Thermostatschalter NRWandmontagetr ger NR Mittel Reflexionsplatte Nordex Heater Spare Parts onau Bwm NR Reflection Sheet 9 Heating Element Lock 14 NR Cable Box SCA Back Frame with O Rings 15 Thermo Knob NR Side Frame 10 Terminal Block Medium 16 Timer Knob NR Stone Holder 11 Cable Holder 17 NR Bottom Cover Heating Element 12 Thermostat Switch 18 NR Wire Set 4 5 9 0 kW Heat Shield Sheet 13 Timer Switch NR Wall Mounting Sheet NR Mid Reflection Sheet
2. ON THE HEATER IT IS REALLY HOT AND CAN CAUSE SERIOUS BURNS HEIZGER T NICHT ZUDECKEN FEUERGEFAHR DO NOT COVER THE HEATER IT MAY CAUSE A FIRE KEIN HOLZ AUF DEN HEIZK RPER LEGEN DO NOT PUT WOOD OF ANY KIND ON THE ELECTRIC HEATER HEIZGER T NIE OHNE STEINE VERWENDEN FEUERGEFAHR NEVER USE THE HEATER WITHOUT STONES IT MAY CAUSE A FIRE WEDER CHLORIERTES WASSER z B BADEWASSER ODER JACUZZI NOCH SEEWASSER VERWENDEN ES KANN ZUR ZERSTORUNG DES HEIZGERATS FUHREN DO NOT USE CHLORINATED WATER e g FROM THE SWIMMING POOL OR JACUZZI OR SEAWATER IT CAN DESTROY THE HEATER Einstellungen TERMOSTAT Thermostat Die Temperatur der Sauna stellen Sie einfach durch das Drehen des Regelknopfs ein Drehen Sie den Regelknopf nach rechts um die Temperatur zu erh hen und nach links um sie zu verringern Wenn es zur berhitzung des Heizger ts kommt wird der Sicherheitssensor das Heizger t automatisch oppen selbst wenn der Zeitschalter eingeschaltet ist Stellen Sie die Ursache der Uberhitzung fest Sie kann durch zu dicht aneinander gelegte Saunasteine die unrichtige Anbringung des Heizger ts oder unzureichende L ftung verursacht sein Beseitigen Sie die Ursache des Problems bevor Sie den Thermostat neu einstellen Die Reset Taste befindet sich unter dem Temperaturreglerknopf ZEITSCHALTER Zur Einschaltung des Heizger ts drehen Sie den Knopf auf einen beliebigen Wert zwischen 1 und 4 auf der Betriebszeit
3. gers Wall Mounting Rack Installation LA Zn 2 C 250 NOTE Remove the carton from the heating elements and behind the serial number between outer and inner cover before installing the heater as it is only intended to protect them during shipment I a e ii I us NR 45NB 50 50 130 270 NR 45NS 50 50 130 270 NR 60NB 50 50 130 270 NR 60NS 50 50 130 270 NR 80NB 80 80 160 330 NR 80NS 80 80 160 330 NR 90NB 80 80 160 330 NR 90NS 80 80 160 330 Heater Installation It is recommended that the heater be placed on the wall nearest to the door The air circulation created by the door should work together with the hot air generated by the heater For safety and convenience follow the minimum safety distances as provided in Fig 1 Follow the cubic volumes given in Fig 7 Do not install the heater to the floor or wall niche Install only one heater in a sauna room Be sure to build a strong foundation for the mounting rack e g cross struts in sauna paneling or reinforce the wall with a thick board to prevent the heater from collapsing Attach the heater to the wall with the aid of the mounting rack Screws 6 pieces are provided for fastening of the rack to the wall To affix the heater to the rack lift the heater and fit the nuts Lock at least one of the side screws to prevent the heater from being accidentally moved A certified electrician must do the installation of the heater to ensure safety a
4. ber Heating of the sauna Always check the sauna room before switching sauna heater on to be sure that there is nothing near the heater When you are using the heater for the first time the heater and the stones may emit smells Make sure that sauna room has been efficiently ventilated If the output of the heater is proper it will take about an hour to reach suitable temperature Fig 8 The temperature in sauna room should be between 60 to 90 C according to the preference of user Too powerful heater will heat sauna room too quickly and the stones won t have enough time to warm The water poured on the stones will not evaporate but flow into the stone holder An underpowered heater on the other hand would lead to an undesirably long heating period Malfunctions If heater doesn t work check the following That the heater has been switched to operating time not to the presetting time Source of electricity to the heater has been switched on The heater s fuses in the household s main fuse box The overheat guard has been resetted if the heater has overheated earlier a T Ersatzteile f r Nordex Heizger t ONOAUVPRWDN NR Reflexionsplatte 9 Halter der Heizelemente 14 NR Kabel Box SCA Hinterrahmen mit O Ringen 15 Thermostatreglerknopf Seitenwand NR 10 Klemmplatte Medium 16 Zeitreglerknopf NR Steinhalter 11 Kabelhalter 17 NR Boden Schutz Heizelement 12 Zeitschalter 18 NR Kabelsatz 4 5 9 0 kW
5. d by persons including children with limited physical or mental abilities and limited experience and knowledge except under close supervision by a responsible person with knowledge and experience or having been advised by such person Under no circumstances should children be allowed to play with the device The electronic and electric system should be mounted in a way so that incoming air will not za Zeitscha Iter interfere with it The control must be mounted outside the sauna cabin En Ti mer EEE Reset Taste Thermostat Reset Button Hole m En IPX4 5 ELEKTRISCHER c a SAUNAOFEN 5 N Nicht f r Inbetriebnahme in den USA Kanada und Mexiko E LECTRIC A Not for use in the USA Canada and Mexico SAUNA HEATER SAWOTEG G X WELLNESS SOLUTIONS nderungen vorbehalten Subject to change without notice NR_ML WICHTIGE HINWEISE IMPORTANT INFORMATION Wenn dieser Saunaofen f r ffentliche Saunen oder f r Saunen in die die Betriebsart Stand By f r Fern wirken eingebaut ist verwendet wird muss die T r der Saunakabine mit einer Verriegelung ausgestat tet sein sodass die Vorbereitung f r die Betriebsart Stand By f r Fernwirken au er Kraft gesetzt wird wenn die Kabinent r ge ffnet wird und die Betriebs art Stand By f r Fernwirken aktiviert ist Stellen Sie sicher dass keine brennbaren Gegen st nde auf dem Saunaofen liegen bevor Sie die Vor wahlzeitfunktion o
6. der die Betriebsart Stand By f r Fernwirken aktivieren If this sauna heater is used for public saunas or for saunas that incorporate a stand by mode setting for remote operation the door of the sauna room must be fitted with an interlock such that the stand by mode setting for remote operation is disabled ifthe sauna door is opened when the stand by mode setting for remote operation is set Make sure that no flammable objects have been placed on the heater before activating the preset time function or the stand by mode for the remote operation Installation des Heizger tes Es empfiehlt sich das Heizger t an der Wand m glichst nahe zur T r anzubringen Die durch die T r verursachte Luftzirkulation sollte zusammen mit der durch das Heizger t erzeugten Hei luft zusammenwirken Aus Sicherheits und Bequemlichkeitsgr nden halten Sie die minimalen Sicherheitsabst nde ein siehe Abb 1 Beachten Sie den in Abb 7 angegebenen Rauminhalt Das Heizger t soll nicht auf dem Boden oder in einer Wandnische installiert werden Installieren Sie nur 1 Heizger t pro Saunaraum berzeugen Sie sich davon da die Unterkonstruktion f r den Montagetr ger z B Querstreben in den Bauplatten der Sauna entsprechend fest ist oder verst rken Sie die Wand mit einer dicken Platte um das Absenken des Heizger ts zu vermeiden Das Heizger t ist mit Hilfe eines Montagetr gers an der Wand zu befestigen Die Schrauben 6 St ck sind f r die Befest
7. e zu speichern um aufgegossenes Wasser zu verdampfen welches die Luftfeuchtigkeit in der Sauna erh ht Sauna steine m ssen einmal im Jahr oder nach 500 Betriebstunden des Ofens je nachdem was zuerst eintrifft komplett ersetzt werden Lose Steinpartikel sollten vom Boden des Ofens entfernt und zersetzte Steine ersetzt werden Die ben tigte Steinmenge k nnen Sie Abbildung 5 entnehmen WICHTIG Benutzen Sie den Saunaofen niemals ohne Steine da dies Feuer verursachen kann Verwenden Sie nur vom Hersteller empfohlene Sawo Steine Die Benutzung ungeeigneter Steine kann zu Heizwendelsch den und Erl schung Ihrer Garantieanspr che f hren Benutzen Sie niemals keramische Steine oder andere gew hnliche Steine Einlegen der Steine in den Saunaofen Es wird empfohlen dass alle Steine vor dem Einlegen in den Ofen mit Wasser von Staub und Flecken befreit werden um den unangenehmen Geruch bei Erstbenutzung zu vermeiden Es ist wichtig dass die Steine lose eingelegt werden damit die Luftzirkulierung im Ofen nicht beeintr chtigt wird Grosse Steine die nicht zwischen die Heizwendeln passen d rfen nicht mit Gewalt eingedr ckt werden Stattdessen sollten diese vom Ofen entfernt werden Lose Steinpartikel oder Steinst cke mit einem Durchmesser geringer als 353mm d rfen nicht im Ofen verwendet werden da diese die Luftzirkulierung im Ofen beeintr chtigen und berhitzung oder Heizwendelsch den hervorrufen WICHTIG Heizwendelsch den als Fol
8. ecommended SaWo stones Using unsuitable stones may lead to heating element damage and will void the warranty Never use ceramic stones or other artificial I stones of any type KEINE KERAMIKSTEINE Loading stones into the heater NO CERAMIC STONES It is recommended that all stones should be rinsed to remove any u stains or dust that can cause unpleasant odour during the first few 3 7 times of using the heater It is important that the stones are loaded N R Y carefully in a way that they do not block air circulation through the heater Larger stones that won t fit between the heating elements must not be forced in place instead they must be completely removed Small crumble or stone pieces smaller than 35mm in diameter must not be loaded into the heater because they will block the air circulation and will cause overheating and possible heating element Ur damage NOTE Heating element damage due to overheating caused by wrong kind of stones or stones which were wrongly loaded into the heater is not covered by the factory warranty Kuva 4 A a Fig 4 U j a Anschlu plan Fig gt Electrical Diagram NR 45NB NR 45NS NR 60NB NR 60NS NR 80NB NR 80NS NR 90NB NR 90NS 3 PHASEN 3 PHASE Separates Steuerger t Separate Control Unit ZEITSCHALTER TERMOSTAT TIMER THERMOSTAT 400V 3N SENSOR 400V 3N 7 Steuerung der elektrischen Hausheizung wahlfreie Verwendung Control of Electric Heatin
9. g in the Household usage is optional N LIL L3 N K 230V Abb 6 Fig 6 Heizelemente SCA150 Abb 7 Technische Daten Fig 7 Technical Data HEIZGER T HEATER kW MODEL en 3x1 5kW 3 x 2 0 kW 3 x 2 66 kW 3 X 3 0 kW 3 x 1 5 kW 3 x 2 0 kW 3 x 2 66 kW 3 X 3 0 kW Heating Elements HEIZELEMENT MODELL kW TYPENNUMMER HEATING ELEMENT TYPE NUMBER SCA150 SCA200 SCA266 SCA300 SCA150 SCA200 SCA266 SCA300 SCA200 SAUNA ROOM MIN oO N UU WU O N U W SUPPLY VOLTAGE 400V 3N 400V 3N 400V 3N 400V 3N 400V 3N 400V 3N 400V 3N 400V 3N SCA266 SIZE OF HEATER SCA300 SAUNARAUM VERSORGUNGS HEIZGER TGR SSE ape st rke STEINE STEUERUNG SICHERUNG SPANNUNG TIEFE HOHE SIZEOF STONES CONTROL FUSE DEPTH HEIGHT mm ns AMP 18 22 kg 18 22 kg 18 22 kg 18 22 kg 18 22 kg 18 22 kg 18 22 kg 18 22 kg Sicherheitsma nahmen Heater Precautions DIE VERDRAHTUNG SOWIE REPARATUREN M SSEN VON QUALIFIZIERTEM FACHPERSONAL AUSGEF HRT WERDEN WIRING AND REPAIRS MUST BE DONE BY A CERTIFIED ELECTRICIAN i TOO h J P Po NOT USE THE HEATER AS A GRILL DAS HEIZGER T NICHT ALS GRILLOFEN VERWENDEN HEIZGER T NIE ALS W SCHETROCKENST NDER VERWENDEN FEUERGEFAHR DO NOT USE THE HEATER AS CLOTHES DRYER IT MAY CAUSE FIRE NIE ZU DICHT AM HEIZGER T SITZEN ES IST WIRKLICH HEISS UND KANN ERNSTE BRANDWUNDEN VERURSACHEN NEVER SIT
10. ge von berhitzung verursacht durch ungeeignete oder falsch eingelegte Steine erl schen Ihre Garantieanspr che SEN a ffnen des Steuerger ts ae Opening of the Control Unit Positionen des Steuerger ts Control Unit Positions Repositioning of the Built In Control Unit Reposition ofthe control unit facing the sides right left or center 1 Remove the screws of the bottom cover Fig 3A 2 Loosen the screws holding the control box Fig 3B 3 Detach the control box from the heating element holder 4 Carefully turn the control box to desired position Fig 3C Do not pull too much away the control box from the heating element holder so that it will not damage thermostat sensor and wiring connections Fig 10 5 Fit the control box back to the heating element holder and tighten the screws 6 Close the bottom cover and tighten the screws Heater Stones The main purpose of the stones in the heater unit is to store enough energy to efficiently vaporize the water thrown on top of the stones to maintain correct humidity in the sauna room The stones must be removed at least once a year or every 500 hours which ever occurs first All stone crumbles must be removed from the heater unit and replaced with new ones as described in the heater manual The required amount of stones is also listed in the manual provided See Fig 4 NOTE Never use the heater without stones as it may cause fire Use only manufacturer r
11. he washroom The size of the exhaust should be twice that of the inlet A B C DEUTSCH ENGLISH Saunabeheizung Kontrollieren Sie stets den Saunaraum bevor Sie das Saunaheizger t einschalten und berzeugen Sie sich davon da sich keine Gegenst nde in der N he des Ger ts befinden Wenn Sie das Heizger t zum ersten Mal verwenden kann das Ger t sowie die Steine einen Geruch von sich geben berzeugen Sie sich davon da der Saunaraum effektiv gel ftet ist Ist die Leistung des Heizger ts richtig eingestellt dauert es ungef hr eine Stunde bis die entsprechende Temperatur Abb 8 erreicht wird Die Temperatur in der Sauna sollte zwischen 60 und 90 C liegen je nachdem was der Benutzer bevorzugt Ein Heizger t mit zu starker Leistung w rde die Sauna zu schnell und die Steine zu langsam erw rmen Das Wasser w rde nicht verdunsten sondern in den Steinkorb laufen Ein zu leistungsschwaches Heizger t andererseits w rde die Aufheizzeit der Sauna zu sehr verl ngern Funktionsst rungen Wenn das Heizger t nicht arbeitet pr fen Sie ob das Ger t auf die Betriebszeit und nicht auf die Zeitvoreinstellung geschaltet ist die Stromversorgung eingeschaltet ist die Sicherungen des Ger ts im Hauptsicherungskasten nicht kaputt sind der berhitzungsschutz nach vorheriger berhitzung neu eingestellt wurde PwmN Zubeh r Schlitze 1 Optional Slots Typennummer siehe Abb 6 Refer to Fig 6 for Type Num
12. igung des Tr gers an der Wand bestimmt Zur Befestigung des Heizger ts am Tr ger heben Sie das Ger t an und passen Sie die Sicherheitsmuttern auf der R ckseite des Heizger ts in den Schlitzl chern auf beiden Seiten des oberen Endes des Tr gers an Sichern Sie wenigstens eine der Seitenschrauben um unbeabsichtigtes Verschieben des Heizger ts zu vermeiden Das elektrische Kabel mu durch einen Kabelkanal mit der Klemmplatte innerhalb des Steuerger ts verbunden sein Das Kabel mu Typ HO7RN F oder gleichwertig sein Wenn das Kabel angeschlossen wird mu das Steuerger t Abb 3A Das Heizger t wird sehr hei Um die Gefahr einer versehentlichen Ber hrung zu vermeiden empfiehlt es sich eine Abschirmung anzubringen Reservieren Sie gen gend Platz f r die Bet tigung der Zeit und Temperaturreglerkn pfe Abb 2 Die Elektroinstallation des Heizger ts mu aus Sicherheits und Verl lichkeitsgr nden von qualifiziertem Fachpersonal ausgef hrt werden Unsachgem e elektrische Anschl sse k nnen Stromschlag oder Feuer verursachen Siehe Anschlu plan in Abb 6 Abb 1 Fig 1 Minimale Sicherheitsabst nde Minimum Safety Distances mm ANMERKUNG Bevor Sie das Heizger t installieren sind die Kartons von den Heizelementen und hinter der Seriennummer zwischen der u eren und inneren Abdeckung abzunehmen weil sie lediglich zum Schutz der Heizelemente w hrend des Transports dienen Installieren des Wandmontagetr
13. ing the operating knob Thermostat support automatically the choosen temperature In case the heater overheats the safety sensor will automatically stop the heater even ifthe timer is on Find out for what reason the heater overheated The reason for this could be too tightly placed sauna stones heater s location or inappropriate ventilation If this occurs find out the cause and fix the problem before resetting the safety sensor TIMER To start the heater at once turn the knob to anywhere between 1 4 on the operating time scale The heater will start and remain on for the time selected Insulation The sauna must have proper insulation on the walls ceiling and door One square meter m of uninsulated surface increases the cubic volume by approximately 1 2m when determining the power requirement of the heater Refer to Fig 7 Ensure that moisture proofing is appropriate in sauna room The purpose of this is to Be spreading of moisture to the other rooms or wall structure Moisture proofing must e placed between heating insulation and panel Nordic spruce wood is recommended for the walls and ceiling inside the sauna Thermal and moisture proofing need to be installed according to the following order from outside to inside 1 Therecommended minimum thickness of the thermal insulation in the walls is 50 mm and in the ceiling 100 mm 2 Itis possible to use carton or aluminum foil laminate as a vapor barrier which is affixed over
14. nd reliability Improper electrical connections can cause electric shock or fire Refer to the electrical diagram in Fig 5 An electrical supply cable must be connected to the terminal block inside the control unit through the cable channel The cable must be HO7RN F type or its equivalent To connect the cable the control unit must be opened Fig 3A The heater gets very hot To avoid the risk of accidental contact with the heater it is recommended that a heater guard be provided Reserve enough space for operation ofthe timer and thermostat knobs Follow the directions given in Fig 2 Abb 2 Fig 2 nderung der Position der Steuereinheit nderung der Position der Steuereinheit mit Ausrichtung nach rechts links oder zur Mitte 1 Entfernen Sie die Schrauben der Bodenabdeckung Abb 3A 2 L sen Sie die Halteschrauben der Steuereinheit Abb 3B 3 Entfernen Sie die Steuereinheit vom Halter der Heizelemente 4 Drehen Sie die Steuereinheit vorsichtig in die gew nschte Position Abb 3C Ziehen Sie die Steuereinheit nicht zu weit weg vom Halter der Heizelemente damit der Thermostatsensor und die Verkabelung nicht besch digt werden Abb 10 5 Verbinden Sie die Steuereinheit wieder mit dem Halter der Heizelemente und ziehen Sie die Schrauben fest an 6 Befestigen Sie die Bodenabdeckung und ziehen Sie dabei die Schrauben fest an Saunasteine Korrekt in den Sauaofen eingelegte Saunasteine dienen dem Zweck W rmeenergi
15. skala Das Heizger t schaltet sich ein und bleibt f r die gew hlte Zeit in Betrieb Zeitschalter Timer Isolierung Die W nde die Decke und die T r des Saunaraums m ssen mit entsprechender Isolierung versehen sein Ein Quadratmeter m einer nicht isolierten Oberfl che erh ht den W rmebedarf um ungef hr 1 2 m Abb 7 Der Saunaraum mu ausreichend isoliert sein um ein Eindringen von Feuchtigkeit in die W nde oder in Nebenr ume zu vermeiden Zwischen Heizungsisolierung und Bauplatte mu eine Feuchtigkeitssperre angebracht werden Die W rmed mmung und die Feuchtigkeitssperre sind in der nachstehenden Reihenfolge von au en nach innen zu installieren 1 Die empfohlene Mindestst rke der W rmed mmung an den W nden betr gt 50 mm und auf der Decke 100 mm 2 Es kann entweder Pappen oder Aluminiumfolie Laminat als Dampfsperre verwendet werden das ber der Aluminium Isolierfolie innen befestigt wird 3 Zwischen der Dampfsperre und der Innenbauplatte mu eine Luftspalte von mindestens 20 mm verbleiben 4 Um Feuchtigkeitsbildung hinter der Bauplatte zu vermeiden ist eine Nut zwischen der Wandplatte und der Decke zu behalten L ftung Zum Saunavergn gen ist eine richtige Mischung der hei en und der kalten Luft im Saunaraum erforderlich Ein weiterer Grund f r die L ftung ist das Ansaugen der Luft rund um das Heizger t und die gleichm ige Verteilung der W rme in der gesamten Sauna Die Anordnung der Luf
16. tein und Austritts ffnungen kann in Abh ngigkeit vom Design des Saunaraums oder nach anderen pers nlichen W nschen gestaltet werden Es empfiehlt sich Nordisches Fichtenholz f r die W nde und die Decke im Inneren der Sauna zu verwenden Die Lufteintritts ffnung kann an der Wand direkt unter dem Heizger t Abb 8A installiert werden Wird die k nstliche L ftung eingesetzt kann die Sl wenigstens 60 cm ber dem Heizger t Abb 8B oder auf der Decke ber dem Heizger t Abb 8C angebracht sein Auf Grund dieser Anordnung wird die schwere kalte Luft die in die Sauna geblasen wird mit der leichten hei en Luft des ee gemischt und bringt den Badenden frische Luft zum Atmen Die empfohlene Gr e der Lufteintritts ffnung ist 5 10 cm Die Luftaustritts ffnung sollte diagonal gegen ber der Eintritts ffnung liegen Es empfiehlt sich die Austritts ffnung in einer Sauna unter der Plattform m glichst weit von der Frischluft ffnung entfernt zu installieren Sie sollte nah am Boden installiert sein oder durch ein Rohr aus dem Boden zu einer ffnung in der Saunadecke oder unter der T r in den Waschraum gef hrt werden In diesem Falle mu die Schwellenrille mindestens 5 cm betragen und es empfiehlt sich den Waschraum mit k nstlicher L ftung auszustatten Die Gr e der Luftabfuhr ffnung sollte das Zweifache der Eintritts ffnung betvragen ana Control Settings THERMOSTAT Adjust the temperature of the sauna by simply turn
17. the insulation aluminum foil inwards 3 Leave at least 20 mm air slot between vapor barrier and inside panel 4 To prevent gathering of the moisture behind the panel leave the slot between wall panel and ceiling Air Ventilation To have a soothing sauna there should be a proper mixing of hot and cold air inside the sauna room Another reason for ventilation is to draw air around the heater and move the heat to the farthest part of the sauna The positioning of the inlet and outlet vents may vary depending on the design of the sauna room or preference of the owner The inlet vent may be installed on the wall directly below the heater Fig 8A When using the mechanical ventilation inlet vent is placed at least 60 cm above the heater Fig 9B or on the ns above the heater Fig 8C Through these positions the heavy cold air that is blown into the sauna is mixed with the light hot air from the heater bringing fresh air for the bathers The inlet vent must have a diameter of 5 10cm recommended The outlet vent should be placed diagonally opposite to the inlet It is recommended that the outlet vent is placed under the platform in a sauna as far as possible from the fresh air vent It may be installed near the floor or led outside through a pipe from the floor geing to a vent to the sauna ceiling or under the door to the washroom In this case the sill slot must be at least 5 cm and it is recommended that there is mechanical ventilation in t
18. wN NORDEX NEXT Einbausteuerger t i Ballen Convoi Uni SAWOTEC BEDIENUNGSANLEITUNG MANUAL NR 45NB NR 60NB NR 80NB NR 90NB NR 45NS NR 60NS NR 80NS NR 90NS 12 l Wir gratulieren Ihnen zum Kauf Ihres SAWOTEC Saunaheizger ts a o N Bevor Sie das Heizger t benutzen lesen Sie sich bitte die u Bedienungsanleit ng sorgf ltig durch N Congratulations on your purchase ofa SAWOTEC sauna heater Please read the manual carefully before using the heater 15 A lt gt Heizelemente e en m Heating Elements Abb 10 Anordnung der Sensoren b Fig 10 Sensor Location Dieses Ger t ist nicht daf r bestimmt durch Personen einschlie lich Kinder mit eingeschr nkten physischen sensorischen oder geistigen F higkeiten oder mangels Erfahrung und oder mangels Real egliersensor Wissen benutzt zu werden es sei denn sie werden durch eine f r ihre Sicherheit zust ndige Regulating Sensor a een d Person beaufsichtigt oder erhielten von ihr Anweisungen wie das Ger t zu benutzen ist S ety enso Kinder sollten beaufsichtigt werden um sicherzustellen dass sie nicht mit dem Ger t spielen Der Anschluss und die Lage der Regel und oder Steuereinrichtung im Saunaraum der F hler des Thermostaten muss so angebracht sein dass er nicht durch einstr mende Luft beeinflusst wird Das Bedienteil ist au erhalb der Kabine zu montieren Seriennummer SerialNumber This product is not designed to be use