Home

LM OG-P2 Advanced - REMAG AG Mess

image

Contents

1. Badger Meter shall as its option repair or replace the product found defective by its inspection or refund the price paid by the enduser for that product Badger Meter s liability and the enduser s rights under this warranty shall be limited to such repair replacement or refund and in particular shall not extend to any direct special indirect or consequential damage or losses of any nature Note This warranty does not form part of nor does it constitute a contract between Badger Meter and the enduser It is additional to any warranty given by the seller of the products and does not exclude limit restrict or modify the rights and remedies conferred upon the enduser or the liabilities imposed on the seller by any statute or other laws in respect of the sale of the product 3 LM_OGP2Adv_BA_89_1008 Table des matieres page 43 92 1 D claration de renonciation uuuuuuuunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 45 Zo AVETUSSEHMIENT EE 45 2 1 Risques d explosion et d incendie nn nn nn nenn nennen nenne 45 2 2 Risques pour le compteur ooccccccnnnncnnineninennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnrnnnrineninnnis 45 3 Touches de l appareil de mesure nes 47 E Ecran LED ia 47 5 Montage de Papparel ioiionicinoniacicniiaicr ri 48 5 1 R duction pression Syst me un nd ese ech 48 5 2 IMSS Br FOROS eier ad 48 53 n 11 u 07 0 GT 48 5 4 Raccordement du tuyau sur Tapparel nn nenn nennen 49
2. Beachte Markierungen f r Batteriepolung finden Sie im Batteriefach 4 Gebrauchte Batterien ordnungsgem ss laut rtlichen Bestimmungen entsorgen Beachte Ein Batteriewechsel hat keinerlei Auswirkungen auf programmierte Werte oder Summen gt LM_OGP2Adv_BA_89_ 1008 Werkseinstellungen ndern Seite 12 92 9 Werkseinstellungen ndern Jedes Messger t wird im Werk f r die Verwendung von Motorendl s Punkt 9 3 Skalierfaktor ndern geeicht Die Masseinheit wird ebenfalls vor Versand gew hlt Firmware Version pr fen 1 tora Taste und Knopf 1 gleichzeitig gedr ckt halten um die Version der Firmware und den Code am Display anzuzeigen 2 Die letzten zwei Ziffern unten rechts sind die Firmware Version 3 Bei Z hlern mit der Version 17 oder h her bitte unter 9 2 Masseinheit ndern und 9 3 Skalierfaktor ndern nachsehen 9 1 Programmierung Werkseinstellungen ndern 1 IO Taste und Knopf AUTO gleichzeitig gedr ckt halten u 2 PrG erscheint am Display TOTAL Taste und auto Taste loslassen Folgende Tasten in der Reihenfolge dr cken und wieder loslassen 1 TOTAL 10 o1 Ind TOTAL 5 Die aktuelle Ma einheit blinkt Sie sind im Programmiermodus 9 2 Masseinheit ndern Das Messgerat bietet die Option unter 4 verschiedenen Masseinheiten zu wahlen Skalierfaktorstellen 1 Die aktuelle Ma einheit blinkt sobald der Pro grammiermodus eingegeben wird 0 4 4 4 CN 2 Die
3. 1 Verify unit of measure is correct 2 Push and hold the total button and auto button together to verify that the scale factor is correct D LM_OGP2Adv_BA_89_1008 Calculate scale factor page 35 92 10 Calculate scale factor A scale factor is a number used to adjust meter accuracy The scale factor is set at the factory using motor oil with a viscosity of 10W The primary use for scale factor recalibration is to batch fluids with different viscosities If the fluid has a lower viscosity more fluid can slip past the meter gears without being detected Changing the scale factor adjusts the meter to compensate for the loss The meter multiplies each pulse by the scale factor number to correct the accuracy when it converts to the specified units The reading is then always correct For an approximate scale factor for fluids of different viscosities consult the chart on page NOTE The meter s original scale factor was written on the trigger when it was calibrated at the factory It may have been revised after field installation Use the scale factor showing on the display not on the trigger Changing the scale factor will change the accuracy of the meter potentially causing it to overfill or under fill This has the potential to cause a mechanical breakdown To view the current scale factor Press and hold the TOTAL button and the L Auro button at the same time 10 1 Absolute scale factor For absolute scale factor perform
4. 3 Meter Europa GmbH LM OG P2 Advanced Elektronischer Vorwahlz hler Electronic preset meters Compteur de pr s lection lectronique Medidores electr nicos programables BEDIENUNGSANLEITUNG INSTALLATION AND OPERATION MANUAL MANUEL D UTILISATION MANUAL DE INSTALACION Y OPERACION 08 2010 LM_OGP2Adv_BA_89 1008 Inhaltsverzeichnis INTE D SA La LISE LE ESP nn ei T REC Ee EE 2 Warnhinweise AAA AA 2 1 Explosion sowie Brandoetaht ttnn tennta nann nnen nanna nn Ennen 22 Gefahren f r den CL 3 Tasten auf dem Messger t nn an 4 LOD DISPIAY iii D G rateeinbaU rc 5 1 SySiemoruck reduzieren 52 O 53 SA E 5 4 Gerat an Schlauch anschliessen iii ii rnane nnee ee 5 5 D se an Ger t anschliessen LL 6 Ger tebedlen ung E 6 1 Manueller ModUS cui era Ran 6 2 Auto Batch Modus nn nn nn nn nenn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnne 6 3 Aufw rts Abw rtsz himodus nn nn nenn nn nn nenna ennnen 7 Betriebsfunktionen E 7 1 R cksetzbare aufgelaufene Summen incooooccccnnnncconononnnnonnnnnnncnonanononnnnnnnnnnnnnannnnnnnnnnos 7 2 Hand Notbet tigung cccccccccccncnineninnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnrinneninenss 7 3 Verlauf alista 7 4 Durchflussmenge cccccccccecceeccceceeeeeeeceeeeeeeeeeeeeeeeeneceeeceeeeeeeccneeeeeseeeeseesseneseeseeneneass LO Eeler eeneg nn ein endete Bs OF VIC TE O IO On T 8 1 Batterie SCRWACN iio a e nn rennen 8 2 Batterieausiausch ttnt t rnrn
5. Empleado en el modo manual para borrar la cantidad dosificada Empleado en el modo de dosificaci n autom tica para borrar la cantidad dosificada y reinicializar el medidor para la siguiente dosificaci n Empleado para reinicializar el total dosificado mientras se presiona el bot n TOTAL Apagado o Paro O Empleado para detener el flujo en una anulaci n de emergencia 3 LM_OGP2Adv_BA_89_1008 Pantalla LCD p gina 71 92 4 Pantalla LCD 2 1 Despliega el total reiniciable total acumulado y PT el factor de escala L QT E Despliega las unidades de medici n ski bi d GAL rey ess Je Las flechas notifican cuando la cuenta es creciente o decreciente H H H H Cantidad de dosificaci n programada cono del Historial x AUTO es un indicador de estar en modo EPM 76 5 4 Icono indicador de bater a baja LCD Display D NOOA 5 Instalaci n del Medidor 5 1 5 2 Liberar la presi n en el sistema 1 Apague la fuente de alimentaci n de la bomba o de la v lvula de cierre 2 Descargue cualquier l quido en el sistema en un contenedor de residuos mediante la apertura del los medidor es 3 Abra todas las v lvulas de purga maestras de aire y del medidor de liquidos s en el sistema 4 Deje el los medidor es abierto s hasta que este listo para presurizar el sistema Equipo Presurizado Este equipo se mantiene presurizado hasta que la presi n es liberada manualmente Para
6. Diagramm auf Seite 15 Beachte Der Original Skalierfaktor des Messger tes steht auf der Ausl sevorrichtung die werksseitig eingestellt wurde Er kann nach dem Einbau berpr ft worden sein Verwenden Sie den auf dem Display angezeigten Skalierfaktor und nicht den der auf der Ausl sevorrichtung genannt wird Durch nderung des Skalierfaktors ndert sich die Genauigkeit des Messger tes was m glicherweise bedeutet dass zu viel oder zu wenig gemessen wird Dies k nnte zu einem mechanischen Defekt f hren Aktuellen Skalierfaktor anschauen Die mm und auto Tasten gleichzeitig dr cken und halten 10 1 Absoluter Skalierfaktor Um den absoluten Skalierfaktor zu bekommen folgenden Test durchf hren 1 Eine abgemessene Menge an Fluid durch das Messger t fliessen lassen 2 Wenn 4 20 quarts durchgeflossen sind und das Display zeigt aber nur 4 00 quarts an bedeutet dies dass der Skalierfaktor neu eingestellt werden muss 3 Den Betrag der durch das Messger t geflossen ist 4 20 durch den Betrag den das Display angezeigt hat 4 00 dividieren So bekommt man einen Fehlfaktor von 1 05 4 Der momentane Skalierfaktor betr gt 1 0123 wie unter Aktuellen Skalierfaktor anschauen s o gezeigt 5 Neuen Faktor berechnen 1 0123 aktueller Skalierfaktor x 1 05 Fehlfaktor 1 0629 neuer Skalierfaktor 6 Die Zahl wie unter Skalierfaktor ndern beschrieben eingeben Beachte Den auf dem Display gezeigten Skalierf
7. Opci n de Rango de Flujo NOTA El rango del flujo solo puede ser mostrado cuando el fluido est pasando por el medidor C digos de error El medidor tiene un c digo de error que puede ser desplegado Provee una indicaci n al medidor de que existe un error en la comunicaci n entre el medidor y el teclado SFO scale factor 0 el factor de escala configurado para el medidor es de 0 000 Para ingresar un factor de escala v lido para el medidor siga las instrucciones en la secci n 9 Cambio de configuraci n de f brica Todos los dem s C digos de Errores son para efectos de f brica solamente e Para eliminar los c digos presione reset 3 LM_OGP2Adv_BA_89_1008 Servicio p gina 79 92 8 Servicio 8 1 Baja bater a Cuando las bater as requieren carga aparecer n una serie de advertencias de forma progresiva en la pantalla del medidor Primera Advertencia El cono de la bater a aparece QT jen la esquina inferior izquierda de la pantalla Esto SW significa que las baterias tienen baja su carga y requieren recargarse Segunda Advertencia El cono de la bater a I comienza a parpadear La carga en las bater as es tan baja y las funciones del medidor son deshabilitadas icono de baja bateria 8 2 Cargando las bater as El compartimento de las baterias se encuentra localizado en la parte inferior del caso en la parte inferior del protector del gatillo 1 Voltee la unidad 2 Desa
8. Temp rature d utilisation mini 20 F 5 C Tol rance mesure huiles 0 5 0 5 Tol rance mesure Produit antigel 1 5 1 5 Ecran LCD affichage 5 chiffres Quarts pints gallons Litres Raccords entr e et sortie gt NPT Ve BSPP 3 LM_OGP2Adv_BA_89_1008 Calcul du facteur de cadrage Page 62 92 N Piece Description piece N d article USA N d article BME 1 Compartiment piles 64103 026 320343 2 Couvercle compartiment vis 64103 003 320355 3 LM_OGP2Adv_BA_89_1008 Calcul du facteur de cadrage Page 63 92 N Piece Description piece N d article USA N d article BME 1 Ecran 64103 023 320376 2 EPM2 unit 64103 025 320377 d enregistrement Non Raccord articul NPT 64082 001 503008 repr sent Non Entretoise caoutchouc 65546 001 320374 repr sent 3 LM_OGP2Adv_BA_89_ 1008 Calcul du facteur de cadrage Page 64 92 N Piece Description piece N d article USA N d article BME 1 Unite vanne 64103 010 320355 2 Unit engrenages avec 62896 001 320353 joint d tancheit O Ring 3 G chette 64103 005 320379 3 LM_OGP2Adv_BA_89 1008 Recherche et suppression de panne Page 65 92 11 Recherche et suppression de panne WARNING R duire la pression avant d effectuer la v rification ou la r paration du compteur S assurer que toutes les vannes dispositif de r glage et pomp
9. e Lorsque la touche est rel ch e l cran revient son 2 3 GPM 4 affichage de service Option d bit Attention L affichage du d bit se fait uniquement lorsqu il y a passage de fluide dans le compteur Codes d fauts L appareil de mesure dispose de codes d fauts pouvant tre affich s ll est possible d afficher le d faut d interface entre l appareil de mesure et le clavier SFO Facteur de cadrage 0 Regler le facteur de cadrage de l appareil sur 0 000 e Pour saisie d un facteur de cadrage valide cf Introduction au chapitre 9 Modifications des param tres usine de ce manuel Tous les autres codes d fauts sont destin s au fabricant de l appareil e Appuyer sur la touche Reset pour effacer les affichages du compteur 3 LM_OGP2Adv_BA_89_1008 Modification des param tres usine Page 56 92 8 Service 8 1 Batterie faible Si les piles doivent tre chang es un symbole d avertissement apparait sur l cran 1 avertissement Si le symbole Batterie faible QT apparait en bas a gauche de l cran les piles sont af uns faibles et doivent tre chang es 2 me avertissement Le symbole Batterie faible _ _ clignote Les piles sont trop faibles et les fonctions de KC l appareil vont amp tre d sactiv es Symbole Batterie faible 8 2 Changement piles Le compartiment des piles se situe dans la partie inf rieure de la gachette 1 Retourner l appareil 2 D visser
10. gina 85 92 Articulo Descripci n de Parte N mero de Parte BMI Numero de Parte BME 1 Ensamble para sost n 64103 026 320343 de baterias 2 Carcasa inferior con 64103 003 320355 tornillos 3 LM_OGP2Adv_BA_89_1008 C lculo del factor de escala p gina 86 92 Articulo Descripci n de Parte N mero de Parte BMI N mero de Parte BME 1 Ensamble de pantalla 64103 023 320376 2 Ensamble registro EPM2 Adv 64103 025 320377 No mostrado Pivote NPT 64082 001 503008 No mostrado Goma de arranque 65546 001 320374 3 LM_OGP2Adv_BA_89_1008 C lculo del factor de escala p gina 87 92 Numero de Parte BME Articulo Descripci n de parte Numero de Parte BMI 1 Ensamble de la v lvula 64103 010 320335 2 Kit de engranes de servicio 62896 001 320353 con O ring 3 Ensamble del gatillo 64103 005 320379 3 LM_OGP2Adv_BA_89_1008 Soluci n de problemas p gina 88 92 11 Soluci n de problemas AWARNING Libere la presi n antes de verificar o reparar un medidor Aseg rese que todas las v lvulas controles y bombas se encuentran operando adecuadamente El icono de la bateria es desplegado Las baterias est n bajas Remplace las baterias Pantalla en blanco Medidor dormido Presione el bot n reset Mala conexi n de baterias Remueva el paquete de las baterias y verifique la conexi n Presione el bot n reset Bater
11. rieure L entr e et la sortie des pi ces de raccordement sont en 1 2 NPT ou 1 2 BSPP selon les mod les Fixer le tuyau Y LM_OGP2Adv_BA_89_1008 Montage de l appareil Utilisation de l appareil Page 50 92 5 5 Fixation de l embo t 1 Sur le c t oppos d poser du produit d tanch it sur le filetage de sortie Produit d tanch it conseill Loctite 243 2 Visser la sortie sur l appareil Serrer fortement l aide d une cl molette 3 Ouvrir toutes les vannes d alimentation D marrer la pompe et mettre le syst me en charge _ 4 Avant utilisation enlever toutes les conduites dar et de fluide ainsi que les vannes d alimentation pour garantir une pr cision de l affichage Fixer l embo t 6 Utilisation de l appareil Attention Commutation de mode manuel en mode Auto Batch en appuyant sur la touche Auto 6 1 Mode manuel En mode manuel l appareil est utilis pour mesurer un 4 4 ae d bit libre 1 Tirer le d clencheur pour d marrer la circulation 2 L affichage indique la valeur mesur e 3 Lorsque la quantit souhait e est mesur e l cher le Mode manuel d clencheur pour stopper la circulation 4 Appuyer 1 fois sur la touche reser pour la remise a z ro de l affichage de l cran Y LM_OGP2Adv_BA_89_1008 Utilisation de l appareil Page 51 92 6 2 Mode Auto Batch Pour arriver dans le module de programmation Auto Batch appuyer sur la touche auro
12. s de los d gitos del factor de escala E d x QT 2 Presione el bot n tom para cambiar el n mero seleccionado NOTA Todos los d gitos pueden ser cambiados entre 0 y 9 excepto el primero Este s lo puede ser cambiado de0a1tode1a0 3 Presione el bot n RESET para avanzar al siguiente n mero en el factor de escala 4 Repita los pasos 2 y 3 para todos los cinco d gitos en el factor de escala Guardar cambios Para guardar cambios y para salir el modod de programaci n 1 Pulsar y soltar al mismo tiempo TOTAL y AUTO 2 La pantalla parpadear tres veces y se apagar 3 Pulsar reset buy la pantalla se repondr en marcha Verificaci n de cambios 1 Verifique que la unidad de medici n es correcta 2 Presione y mantenga presionados los botones de TOTAL y AUTO al mismo tiempo para verificar que el factor de escala es correcto 3 LM_OGP2Adv_BA_89_1008 C lculo del factor de escala p gina 82 92 10 Calculo del factor de escala El factor de escala es un n mero empleado para ajustar la precisi n del medidor El factor de escala es configurado en la f brica empleando aceite para motor con una viscosidad de 10W El uso primario de la re calibraci n del factor de escala es para dosificar fluidos de distintas viscosidades EI fluido tiene una viscosidad menor por lo tanto puede pasar una mayor cantidad de ste por los engranes del medidor sin ser detectado Cambiando el factor de escala se ajusta
13. 5 a Pa Bai GAL 4 HISTORY RESETTOTAL N OO P D Displays resettable total accumulated total and scale factor Displays unit of measure Arrows notify when in count up or count down Preset batch quantity History icon AUTO is an indicator of being in EPM mode Low battery icon LM_OGP2Adv_BA_89_ 1008 Meter installation page 26 92 5 Meter installation 5 1 5 2 5 3 Relieve system pressure 1 Turn off the power supply to the pump or close the shutoff valve 2 Dispense any fluid in the system into a waste container by opening the meter s 3 Open all bleed type master air valves and fluid meter s in the system 4 Leave the meter s open until ready to pressurize the system Pressurized equipment This equipment stays pressurized until the pressure is manually relieved To reduce the risk of injury from fluid spray from the meter follow the pressure relief procedures when you Are instructed to relieve pressure Stop dispensing e Check clean or service any system equipment e Clean or install nozzles Grounding 1 Grounding reduces the risk of static sparking Ground all system components according to local state and federal codes Consult the pump user s manual and other system components to ground the following Pump follow manufacturer s recommendations Air and Fluid Hoses use only grounded hoses Air Compressor follow manufacturers recommendations Fluid Supply Con
14. AL Taste dr cken um zwischen den vier Optionen PT QT GAL L umzuschalten Masseinheit 3 Sobald die gew nschte Masseinheit angezeigt wird Programmier Display die reset Taste dr cken Das Symbol f r die Mass einheit blinkt nicht mehr 4 Wird L Liter gewahlt fangt der Dezimalpunkt an zu blinken Jetzt haben Sie die Option den Dezimalpunkt entweder in einen Punkt oder ein Komma zu ndern e Hierf r Tora Taste dr cken 5 Wird kein Skalierfaktor ben tigt s Punkt 9 4 nderungen speichern 3 LM_OGP2Adv_BA_89_1008 Skalierfaktor berechnen Seite 13 92 Wird die Masseinheit von metrischen auf englische oder von englischen auf metrische Einheiten ge ndert werden die r cksetzbaren und aufgelaufenen Summen gel scht 9 3 Skalierfaktor ndern Durch nderung des Skalierfaktors ndert sich die Genauigkeit des Messger tes was m glicherweise bedeutet dass zu viel oder zu wenig gemessen wurde Dies k nnte zu einem mechanischen Defekt f hren kalierfak I mm l en 1 Die reset Taste dr cken um vorw rts durch die Skalierfaktorstellen zu bl ttern E d x QT 2 Die Tota Taste dr cken um die gew hlte Nummer zu ndern Beachte Alle Stellen zwischen O und 9 ausser der ersten k nnen durchgebl ttert werden Diese kann nur von 0 bis 1 und von 1 bis 0 durchgebl ttert werden Skalierfaktor Display 3 Die RESET Taste dr cken um auf die n chste Zahl im S
15. Read all fluid and solvent manufacturer s warnings Tighten all fluid connections before operating this equipment Do NOT stop or deflect leaks with hands body gloves or rags Do NOT dispense towards any person or any part of the body Do NOT place hands or fingers over the end of or into the dispense valve Comply with all local state and federal fire electrical and safety regulations Use of this product in a manner other than specified in this manual may result in impaired operation or damage to equipment This meter is designed specifically to dispense petroleum products Do not use for windshield wiper fluid brake fluid or water based solutions 3 LM_OGP2Adv_BA_89_1008 Meter buttons 3 Meter buttons RESET Used in ne manual mode to clear the dispensed quantity Used in auto batch mode to clear the dispensed quantity and reset the meter for the next batch Used to reset the resettable total dispensed while pressing the TOTAL button Reset Shut off or stop O page 25 92 10 1 0 1 Used to enter the batch quantity to be dispensed Total TOTAL gt Used to display the accumulated total of fluid dispensed as well as the resettable total during auto batch and manual mode Auto EE AUTO Used to enter ana exit the manual or auto batch mode Used to stop the flow inrougn an emergency override 4 LCD display 1 2 BBB Se 7 6 5 4 LCD Display 3 PT Lor 3
16. Replace batteries Display blank Meter asleep Push reset button Loose battery connection Remove battery pack and check battery connection Push reset button Batteries dead Replace batteries Push reset button Meter does not latch for Meter not in AUTO mode Press AUTO button and batching program batch size Meter not reset after prior batch Press RESET button Low batteries Check for battery icon replace batteries push RESET button Slow or no fluid flow Filter is clogged Clean or replace the filter in the swivel nut Pump pressure is low Turn up the pump pressure Foreign material is jamming meter Contact your local repair distributor Meter inaccurate Scale factor not correct for fluid Enter program mode check and reset program factor Batch overruns program value Pulse delay value set too low Enter program mode reset pulse delay to higher value 3 LM_OGP2Adv_BA_89_1008 Warranty page 42 92 12 Warranty Badger Meter warrants that the products will be free from any defects caused by faulty material or workmanship for a period of twelve 12 months from the date of sale of the products to the enduser the warranty period PROVIDED THAT during the warranty period 1 Badger Meter receives notice setting out full details of any defect in any product and details of the time and place of purchase of the product and 2 The enduser returns the product to Badger Meter or its nearest representative at its own costs
17. The solenoid valve in the meter MATT or Auto automatically locks the dispensing Auto LILI bs Deal valve in the full open position icon D size 43 The meter always locks in the maximum open position 5 Release the trigger allowing it to fall back 6 The flow automatically shuts off after the batch quantity has dispensed 7 After the batch quantity has been dispensed the meter is a free flow dispensing handle until the reset button is depressed NOTE In case of an emergency or to interrupt a batch the meter is equipped with an emergency override see emergency override under 7 2 8 The user has the option to top off the fluid at the end of a batch To top off the fluid pull the trigger to begin the flow and release it when the desired amount has been pumped 9 Press the rst button when finished The display resets and the meter is now ready to dispense the next batch 6 3 Count up count down modes 1 When in the auto batch programming mode press the RESET button and the count up count down arrows flash in the display e Pressthe TOTAL n to toggle between count up count p v i down e Press the weer button to select count up or count YE t down Count up arrow 3 LM_OGP2Adv_BA_89_1008 Meter operation Operating mode functions page 30 92 NOTE In the count up option the meter counts up to y QT the preprogrammed batch amount In the count down t option the meter counts from th
18. Utilice solamente extensiones y boquillas que est n dise ados para su uso con este equipo Utilice s lo los l quidos y solventes que sean compatibles con el equipo Lea todas las advertencias del fabricante del disolvente Ajuste todas las conexiones antes de utilizar este equipo NO parar o desviar las fugas con las manos cuerpo guantes o trapos NO dosificar frente a cualquier persona o cualquier parte del cuerpo NO coloque las manos o los dedos sobre el final o dentro de la v lvula 3 LM_OGP2Adv_BA_89_1008 Introducci n Botones del Medidor p gina 70 92 e Cumplir con todas las regulaciones de seguridades locales estatales federales as como de fuego y electricidad e El uso de este producto de formas distintas de las especificadas en este manual puede resultar en la alteraci n de la operaci n o da o al equipo Este medidor est dise ado espec ficamente para la dosificaci n de productos de petr leo No se emplee para l quido limpiaparabrisas l quido de frenos o soluciones con base de agua 3 Botones del Medidor RESET Reinicializar 10 1 0 1 Empleados para ingresar la cantidad de dosificaci n a ser despachada TOTAL Total Empleado para desplegar el total acumulado del fluido despachado asi como reiniciar el totalizador durante una dosificaci n en modo autom tico y manual Auto Re ne Empleado para ingresar y salir del modo de dosificaci n manual o autom tica
19. al medidor para compensar la p rdida El medidor multiplica cada pulso por el n mero del factor de escala para la correcta precisi n cuando lo convierte a las unidades espec ficas La lectura entonces es siempre correcta Para un factor de escala aproximado para fluidos con distintas viscosidades consulte la gr fica en la p gina 83 NOTA El factor de escala original del medidor fue escrito en el gatillo cuando fue calibrado en la f brica Pudo haber sido revisado despu s de la instalaci n en campo Use el factor de escala mostrado en la pantalla no en el gatillo Cambiando el factor de escala se cambiar la precisi n del medidor causando potencialmente un sobrellenado o un llenado incompleto Esto tiene el potencial de causar una aver a mec nica Para visualizar el factor de escala actual 8 Presione y mantenga presionado el bot n TOTAL y el bot n AUTO al mismo tiempo 10 1 Factor de escala absoluto Para el factor de escala absoluto realice esta prueba 1 Corra una cantidad medida del fluido por el medidor 2 Si el medidor cuenta 4 20 cuartos y en la pantalla solo se muestran 4 00 cuartos entonces el factor de escala necesita ser ajustado 3 Divida el valor del medidor 4 20 entre lo mostrado 4 00 Obtendr un factor de error 1 05 4 El factor de escala existente es 1 0123 como se muestra en Para visualizar el factor de escala actual descrito anteriormente 5 Para calcular el nuevo facto
20. de la dosificaci n l e EI 0 esta parpadeando enfrente a los dos puntos Este es el cono num rico de la dosificaci n S e Dosificaci n 0 es para modo manual V ase modo 5 manual en la secci n anterior e Dosificaciones 1 2 3 4 y 5 son para dosificaciones automaticas hasta 99 unidades Modo Automatico e Diferentes montos de dosificaci n pueden ser programado de dosificaci n almacenados en cada opci n e Dosificaci n 6 es para dosificaciones entre 1 y 999 unidades 1 Presione el bot n de TOTAL para desplazarse por los conos num ricos de las dosificaciones para seleccionar la dosificaci n deseada o el modo manual 2 Cuando aparezca en pantalla el cono num rico de la dosificaci n deseada cambie el tama o de la dosificaci n presionando los botones 1 1 04 e Presione el bot n 10 para incrementar la dosificaci n QT en 10 unidades e Presione el bot n 1 para incrementar la dosificaci n S en 1 unidad 45 t e Presione el bot n 0 1 para incrementar la dosificaci n en 0 1 de unidad Modo de programaci n autom tica de dosificaci n opci n 1 3 LM_OGP2Adv_BA_89_ 1008 Operaci n del Medidor p gina 75 92 NOTA Cuando se programe la opci n 3 D D D or Presione el bot n 10 para incrementar la cantidad de UI AU LI dosificaci n en 100 unidades e Presione el bot n 1 para incrementar la cantidad de J dosificaci n en 10 un
21. dr cken um eine Menge stufenweise um 100 Einheiten zu erh hen e Ter Taste dr cken um Menge stufenweise um 10 Einheiten zu erh hen e 0 1er Taste dr cken um Menge stufenweise um 1 Einheit zu erh hen Auto Batch Programm Modus Option 3 Beachte Siehe Hinweise zum Abw rts Aufw rts Z hlmodus unter 6 3 gt LM_OGP2Adv_BA_89_ 1008 Ger tebedienung Seite 8 92 3 Nach Wahl der Mengen die auto Taste dr cken um die zu messende Menge anzuzeigen und das Fluid zu messen 4 Ziehen Sie die Ausl sevorrichtung um Auto den Durchfluss zu starten MITA or Batch Das Magnetventil im Messger t sperrt Auto LILI Li _Z gr sse automatisch das Messventil in voll Sym ge ffneter Position S 43 Das Messger t sperrt immer bei max ge ffneter Position 5 Die Ausl sevorrichtung loslassen damit es wieder in den urspr nglichen Zustand zur ckkehren kann 6 Der Durchfluss wird nach Erreichen der Menge automatisch abgeschaltet 7 Nach Erreichen der Menge fungiert das Messger t als Ger t mit freiem Durchfluss bis die Reset Taste gedr ckt wird Beachte f r Notf lle oder um eine Menge zu unterbrechen ist das Messger t mit einer Hand Notbet tigung ausgestattet s Hand Notbet tigung unter 7 2 8 Der Bediener kann das Fluid am Ende einer Menge abrunden e Zum Abrunden der Fluidmenge Ausl sevorrichtung ziehen um Durchfluss zu starten und sobald die gew nschte Menge durchgepumpt ist Ausl sevo
22. herewith confirm that our products are in accordance with above mentioned directives The equipment identified above must not be put into service until the machinery into which it is to be incorporated has been declared in confarmity with the provisions of above directives Nous contirmons par la pr sente que nos compteurs sant en accord avec les directives mentionnees ci dessus Avant la mise en service veuillez vous assurer que ensemble de quipement ou nos compteurs vont tre install s soit bien en accord avec les directives en vigueur 02 04 2009 OM LM ZF CE d e sp fr 108doc 09 04 Tel 49 7025 9208 0 Badger Meter Europa GmbH N rtinger Strasse 76 72639 Neuffen Germany Fax 49 7025 9208 15 www badgermeter de E mail badger badgermeter de LM_OGP2Adv_BA_89_1008 DIN ISO Zertifikat Certificate Certificat Certificado 91 92 14 DIN ISO Zertifikat Certificate Certificat Certificado ZERTIFIKAT Die Zertifizierungsstelle der T V SUD Management Service GmbH bescheinigt dass das Unternehmen Badger Meter Europa GmbH N rtinger Strasse 76 D 72639 Neuffen f r den Geltungsbereich Durchflu mess und Regeltechnik Entwicklung Vertrieb und Produktion p Ka o ra EN E UJ oO gt oO bes St gt re ken cc LL oO ke x e gt o wu ein Qualit tsmanagementsystem eingef hrt hat und anwendet Durch ein Audit Bericht Nr 70002816 wurde
23. is now ready to select the desired batch number The 0 is flashing in front of the colon This is the batch number icon Batch 0 is for manual mode see manual mode above Batches 1 2 3 A and 5 are for auto batching amounts up to 99 units Different batch amounts can be stored in each option Batch 6 is for batches between 1 and 999 units 1 Press the TAL button to cycle through the batch number icons to select the desired batch or manual mode 2 When the desired batch number icon appears on screen change the batch size by pressing the 10 1 and UDD ma up Auto batch program mode option 1 3 01 Juttons Press the 10 button to increase a batch by 10 units Press the 1 button to increase a batch by 1 unit Press the 0 1 button to increase a batch by 0 1 of a unit LM_OGP2Adv_BA_89_ 1008 Meter operation page 29 92 NOTE When programming option 3 D D D or Press the 10 button to increase a batch amount in MM LI increments of 100 units e Press the 1 button to increase a batch amount in J increments of 10 units e Press the 0 1 button to increase a batch amount in increments of 1 unit Auto batch program mode option 3 NOTE See Count Up Down Mode specifications under 6 3 3 After the batch size is selected press the AUTO button to lock in the batch and dispense fluid G 4 Pull the trigger to begin the flow
24. jusqu apparition d une valeur et d un double point L affichage suivant apparait L appareil de mesure est pr t pour la saisie du num ro de OT la quantit mesurer A e 0 clignote devant le double point Symbole indiquant le num ro de la quantit a mesurer 2 e La quantit mesurer 0 indique le mode manuel cf H point Mode manuel pr c dent e Les quantit s mesurer 1 et 2 indiquent le mode Auto Batch et affichent jusqu 99 unit s Diff rentes quantit s mesurer peuvent tre m mo ris es dans chaque option e La quantit 3 indique les quantit s mesurer entre 1 et 999 unit s 1 Appuyer sur la touche TOTAL pour parcourir les symboles de quantit s mesurer et pour s lectionner le mode Batch manuel 2 l apparition de l affichage du symbole correspondant la quantit mesurer souhait e saisir l unit de la quantit mesurer en cliquant sur 1 1 et 01 j Appuyer sur la touche des dizaines pour augmenter la g 4 QT quantit de 10 unit s Appuyer sur la touche des unit s pour augmenter la quantit de 1 unit ek t Appuyer sur la touche avec virgule pour augmenter la quantit de 0 1 unit Programme mode Auto Batch option1 Attention Lors de la programmation de l option 3 rm A D QT e Appuyer sur la touche des dizaines pour augmenter la UU LS quantit par palier de 100 unit s e Appuyer
25. minimum Accuracy oils Accuracy anti freeze 5 digit LCD display Inlet and outlet connections Y LM_OGP2Adv_BA_89_1008 English 10 gpm 0 25 gom 1000 psi 5 psi 120 F 20 F 0 5 1 5 Quarts pints gallons Vo NPT Metric 38 l min 1 l min 67 bar 0 35 bar 50 C 5 C 0 5 1 5 Liters V2 BSPP page 37 92 Calculate scale factor page 38 92 ITEM Part description Part number of BMI Part number of BME 1 Battery holder assembly 64103 026 320343 2 Bottom case with srews 64103 003 320355 Y LM_OGP2Adv_BA_89_1008 Calculate scale factor page 39 92 ITEM Part description Part number of BMI Part number of BME 1 Display assembly 64103 023 320376 2 EPM2 Adv register assembly 64103 025 320377 Not shown Swivel NPT 64082 001 503008 Not shown Rubber boot 65546 001 320374 Y LM_OGP2Adv_BA_89_1008 Calculate scale factor page 40 92 ITEM Part description Part number of BMI Part number of BME 1 Valve assembly 64103 010 320335 2 Gear service kit with O ring 62896 001 320353 3 Trigger assembly 64103 005 320379 Y LM_OGP2Adv_BA_89_1008 Troubleshooting page 41 92 11 Troubleshooting AWARNING Relieve the pressure prior to checking or repairing the meter Make sure all valves controls and pumps are operating correctly Battery icon is displayed Batteries are low
26. reducir el riesgo de accidentes o da o proveniente de alg n spray del medidor siga los procedimientos de liberaci n de presi n cuando e Se le ha dado la instrucci n de liberar la presi n e Detenga una dosificaci n e Verifique limpie o de servicio al cualquier equipo del sistema e Limpie o instale boquillas Aterrizaje 1 El aterrizaje reduce el riesgo de chispas por carga est tica Aterrice todos los componentes del sistema conforme a los c digos locales estatales y federales Consulte el manual del usuario de la bomba y de los otros componentes del sistema para aterrizar lo siguiente Bomba siga las recomendaciones del fabricante Mangueras de aire y fluido emplee solamente mangueras aterrizadas Compresor de aire siga las recomendaciones del fabricante Contenedor del fluido siga el c digo local OPO OD 3 LM_OGP2Adv_BA_89_1008 Instalaci n del Medidor p gina 72 92 5 3 Explosion y fuego El movimiento de los fluidos a trav s del sistema de dosificaci n crea carga est tica La carga est tica puede causar la explosi n y o fuego de gases vol tiles El sistema de dosificaci n debe ser aterrizado Procedimiento de enjuagado NOTA Si el sistema tiene m ltiples posiciones de dosificaci n inicie con la posici n m s lejana a la bomba y mu vase acerc ndose a ella 1 2 3 Coloque la parte final de la manguera en un contenedor de residuos Asegurese Cierre las valvulas de dosificaci n
27. sur la touche des unit s pour augmenter la quantit par palier de 10 unit s 3 d d d Appuyer sur la touche avec virgule pour augmenter la 7 quantit par palier de 1 unit Programme mode Auto Batch option 3 Attention Cf indications pour mode compteur croissant d croissant au point 6 3 3 LM_OGP2Adv_BA_89_1008 Page 52 92 Utilisation de l appareil 3 Apr s s lection de la quantit appuyer sur la touche a mesurer et mesurer le fluide Cauro pour afficher la quantite 4 Tirer sur la g chette pour d marrer la distribution Auto nn or a La soupape magnetique du compteur Sym LE UU ala bloque automatiquement la soupape de bole N mesure en position d ouverture maximale 6 3 a L appareil bloque syst matiquement en position ouverture maximale 5 Lacher la g chette pour qu elle puisse revenir a l etat initial 6 Le d bit est automatiquement stopp lorsque la quantit est atteinte 7 Lorsque la quantit est atteinte le compteur agit comme un appareil a debit libre jusqu a ce que la touche de Reset soit validee Attention Le compteur est dot d un bouton d arr t d urgence en cas d urgence ou pour interrompre la quantit cf Arr t d urgence manuel point 7 2 8 L utilisateur peut lorsque le debit est atteint arrondir le volume Pour arrondir la quantit du volume de fluide tirer sur la g chette pour d marrer la distribution et lorsque la quantit so
28. tes dans le mode de programmation 9 2 Modification unit s de mesure Le compteur autorise 4 unit s de mesure diff rentes FRERES 1 L unit de mesure de r f rence clignote des la saisie du mode programmation 0 ar 2 Appuyer sur la touche TOTAL pour choisir sur l une des 4 options PT QT GAL L Unit de mesure 3 D s que l unit de mesure est affich e appuyer sur Affichage de programmation la touche reset Le symbole de unit de mesure s arr te de clignoter 4 En choisissant L litre le s parateur de la d cimale clignote e L affichage du s parateur de d cimale peut tre au choix un point ou une virgule Pour cela appuyer sur la touche TOTAL 5 Aucun facteur de cadrage n est n cessaire cf M morisation de modifications point 9 4 Y LM_OGP2Adv_BA_89_1008 Modification des param tres usine Page 58 92 9 3 9 4 9 5 En cas de modification de lunit de mesure m trique en unit de mesure anglaise ou inversement les suites des sommes en m moire sont effac es Modification facteur de cadrage Le changement du facteur de cadrage modifie la pr cision de l appareil de mesure la quantit mesur e peut tre inf rieure ou sup rieure Ceci peut occasionner un d faut m canique Position facteur de cadrage a 1 Appuyer sur la touche RESET pour feuilleter les positions de facteur de cadrage QT num ro s lectionn gt D d Xx 2 Appuyer sur la touche TO
29. this test 1 Run a measured amount of fluid through the meter 2 If the meter delivers 4 20 quarts and the display shows only 4 00 quarts then the scale factor needs to be adjusted 3 Divide what the meter delivered 4 20 by what the display shows 4 00 You get an error factor of 1 05 4 The existing scale factor is 1 0123 as shown under To view the current scale factor above 5 To calculate a new factor 1 0123 existing scale factor x 1 05 error factor 1 0629 new scale factor 6 Enter that number as described in Change scale factor NOTE Use the scale factor showing on the display not on the trigger 3 LM_OGP2Adv_BA_89_1008 Calculate scale factor page 36 92 Chart of approximate scale factors for fluids of different viscosities Scale factor Scale factor o w 1 00 0 99 a HH E ETH EREE EEEE l 10 100 1000 10000 Viscosity in centistokes at 65 Samples of fluids viscosities and scale factors Fluid Viscosity Scale factor 1 Water anti freeze 5 1 044 2 Anti frezze 18 1 007 3 Brake fluid 42 1 004 4 ATF 80 1 002 5 10W 140 1 000 6 80W 90 450 0 999 7 140W 1800 0 993 D LM_OGP2Adv_BA_89_1008 Calculate scale factor 11 0 SPECIFICATIONS Maximum flow Minimum flow Operating pressure maximum Operating pressure minimum Operating temperature maximum Operating temperature
30. to local regulations NOTE Changing the batteries does not affect any of the programmed values or totals Y LM_OGP2Adv_BA_89_1008 Change factory settings page 33 92 9 Change factory settings Each meter is calibrated at the factory for use with motor oil see Change scale factor under point 9 3 The unit of measure is also selected prior to shipment Verify Firmware version 1 2 3 9 1 9 2 The firmware version and code checksum can be displayed by holding the TOTAL and 1 button at the same time The last two digits on the lower right are the firmware version Meters with version 17 or higher use the procedure outlined in this manual for changing of unit of measure and scale factor Programming To change the factory settings 1 Push and hold at the same time the TOTAL and AUTO buttons u 2 PrG will appear on the display 3 Release the TOTAL and AUTO Juttons 4 Then press and release in order the 1 tora 10 or and the tora puttons 5 The current unit of measure will now be flashing indicating that you have entered the programming mode Change unit for measure The meter comes with an option to choose 4 different units of measure Scale factor digits 1 The actual unit of measure is flashing when the pogramming mode is entered 0 Se 2 Press the TOTAL button to toggle between the four options PT QT GAL L Unit of measurement 3 When the desired unit of measu
31. 03 026 320343 2 Unterteil mit Schrauben 64103 003 320355 3 LM_OGP2Adv_BA_89_1008 Skalierfaktor berechnen Seite 18 92 ee GEN en III STA HO Ev Teil Nr Teile Beschreibung Teile Nummer von BMI Teile Nummer von BME 1 Anzeige 64103 023 320376 2 EPM2 64103 025 320377 Registereinheit nicht Drehgelenk NPT 64082 001 503008 abgebildet nicht Gummist ck 65546 001 320374 abgebildet 3 LM_OGP2Adv_BA_89_1008 Skalierfaktor berechnen LS NE SS A NOS Seite 19 92 Teile Nummer von BME Teile Nr Teile Beschreibung Teile Nummer von BMI 1 Ventileinheit 64103 010 320355 2 Getriebe Service Paket 62896 001 320353 mit O Ring 3 Ausl sevorrichtung 64103 005 320379 3 LM_OGP2Adv_BA_89_1008 Fehlersuche und beseitigung Seite 20 92 11 Fehlersuche und beseitigung Druck vor dem berpr fen und Reparieren des Messger tes reduzieren Sicherstellen dass alle Ventile Regler und Pumpen einwandfrei funktionieren Merkmal M gliche Ursache Abstellmassnahme Symbol f r Batterie wird an Batterien sind schwach Batterien ersetzen gezeigt Display dunkel Messger t in Ruhestellung Reset Taste dr cken Batterieverbindung locker Batterien entfernen und und Batterieverbindung berpr fen Reset Taste dr cken Batterien leer Batterien ersetzen Reset Taste dr cken Messger t startet Batching Messger t nicht in AUT
32. 3 LM_OGP2Adv_BA_89_1008 Funciones del Modo de Operaci n p gina 77 92 7 Funciones del Modo de Operaci n Estas funciones operan de la misma forma en los modos manual o dosificaci n autom tica 7 1 7 2 7 3 Totales Reiniciables Acumulados 1 Para visualizar el total acumulado y el total reiniciable e Presione y mantenga presionado el bot n tora para visualizar el total acumulado e Contin e presionando el bot n tora e Despu s de 3 segundos la panta ia cambia al total reiniciable 2 La pantalla de Resettotal muestra el total del d H L fluido despachado desde que el total reiniciable fue puesto en cero RESETTOTAL 3 Presione el bot n EE mientras se visualiza esta pantalla para llevar el valor a cero 4 Deje de presionar el bot n tom para regresar a la pantalla de operaci n NOTA EI total acumulado no puede ser reinicializado a menos que el usuario cambie de unidades inglesas a unidades m tricas o de unidades m tricas a unidades inglesas v ase Cambiar configuraci n de F brica cambio de unidades 9 2 Anulaci n de emergencia En el caso de una emergencia o la interrupci n de una dosificaci n el medidor est equipado con una anulaci n de emergencia 1 Presione el bot n rojo O en el medidor para activar la anulaci n de emergencia La anulaci n cerrar la v lvula deteniendo inmediatamente el flujo del fluido 2 Despu s de una anulaci n de emergencia la dosificaci n pu
33. 5 5 Fixation de Inn 1010 EE 50 6 Utilisation de Kapparell u un seen 50 6 1 Mode Manuelan iste cette she ee a EE aaa 50 6 2 Mode Auto Batch nn nn nn nn nenn nenn nnnnnnnnnnnnnnnnnennnnnnnne 51 6 3 Mode de comptage croissant Jd crolssant tn nnnener eee 52 7 Fonctions op rationnelles ns 54 7 1 Suites des sommes et sommes en m moire 54 7 2 Bouton manuel d arr t d urgence ss 54 7 3 DOCU Mya a E T 55 Ta DA Er e an nn o ME al N ali 55 7 3 EE 55 e E II A 56 8 1 Batterie faible teenreenaeenaeen tentene 56 8 2 Changement TE 56 9 Modification des param tres USINE 57 9 1 Programmation 57 D LM_OGP2Adv_BA 89 1008 Warranty page 44 92 9 2 Modification unit s de mesure 57 9 3 Modification facteur de cadrage nn nn nn nn Ennn Ennen nnee 58 9 4 M morisation de modifications 0000000aneeaneenaeeaneeaneennennnennnnennannnnnnnnnnnnnnnnnnnnenna 58 9 5 Validation de modficaiions nenn nenn nennen nennen 58 10 Calcul du facteur de cadrage ns 59 10 1 Facteur de cadrage absolu 59 11 Recherche et suppression de panne ns 65 1224 GA ln 66 13 Declaration d E le ET E 90 1Ax Gerliticat DIN ISO een ana unten ea nenne A ta 91 3 LM_OGP2Adv_BA_89_1008 D claration de renonciation Avertissement Page 45 92 1 Declaration de renonciation L usager et ou l acqu reur a l obligation de lire assimiler et appliquer les informations ins
34. Ausl se vorrichtung fortgefahren werden Verlauf Mit dieser Option kann der Bediener die vorherigen f nf 5 Mengen die mit dem Messger t gemessen wurden berpr fen 1 Die HISTORY Taste dr cken und halten um die f nf 5 vorherigen Mengen anzusehen e Die Mengen werden auf der Anzeige nach einander Uu d QT angezeigt Als erstes wird die letzte Menge und x danach eine nach der anderen bis zur ltesten PE angezeigt 3 Verlaufsoption e Die Mengen werden solange eine nach der anderen angezeigt wie die History Taste gedr ckt wird 2 Zwei 2 Sekunden nach Loslassen der History Taste springt das Display automatisch in die normale Betriebsanzeige zur ck Beachte Der Verlauf kann erst dann gel scht werden wenn der Bediener von den englischen zu metrischen oder von metrischen zu englischen Einheiten wechselt s Werkseinstellungen ndern unter 9 1 Durchflussmenge Mit dieser Option kann der Bediener sofort die Fluidmenge die durch das Messger t fliesst sehen e Die M LOW RATE Taste w hrend das Fluid durch das Messger t fliesst dr cken Die Durchflussmenge wird in der rechten unteren Ecke des Displays angezeigt el er Solange die Taste gedr ckt bleibt wird die Durch S flussmenge auf dem Display angezeigt 5 E wd e Wird die Taste losgelassen kehrt das Display zur normalen Betriebsanzeige zur ck Durchflussmengenoption Beachte Die Durchflussmenge kann nur dann angezeigt werden
35. Badger Meter o a su representante mas cercano corriendo con los gastos de envio Badger Meter como su opci n reparara o reemplazara el producto que considere deficiente despu s de su revisi n o reembolsar el precio pagado por el usuario final de dicho producto La responsabilidad de Badger Meter y los derechos del usuario final bajo esta garant a se limitar n a dicha reparaci n reemplazo o reembolso y en particular no se extender a da os directos especiales indirectos o consecuentes da os o perjuicios de cualquier naturaleza Nota Esta garant a no forma parte de ni constituye un contrato entre Badger Meter y el usuario final Es adicional a cualquier garant a dada por el vendedor de los productos y no excluye limita restringe o modifica los derechos y recursos que le confiere el usuario final o la responsabilidad impuesta al vendedor por cualquier ley u otras leyes en materia de la venta del producto 3 LM_OGP2Adv_BA_89_1008 Herstellererklarung Manufacturer s declaration D claration du fabricant 90 92 13 Herstellererkl rung Manufacturer s declaration D claration du fabricant Declaracion del Fabricante Ki Badger Meter Europa Herstellererkl rung Declaration du Fabricant C Manufacturers Declaration Declaraci n de Fabricant Bauart Typ Fl ssigkeitsz hler Modelo tipo Medidor de Lubricante Model Type Fluid meter Modele Compteur de liquides Typenbezeich
36. O Modus AUTO Taste dr cken und nicht Mengengr e program mieren Messger t nach vorheriger Menge RESET Taste dr cken nicht r ckgesetzt Batterien schwach Batterie Symbol pr fen Batterien ersetzen RESET Taste dr cken Fluid flie t langsam oder Filter verstopft Filter reinigen oder gar nicht ersetzen Pumpendruck zu niedrig Pumpendruck erh hen Fremdk rper verstopfen Messger t H ndler Lieferanten vor Ort kontaktieren Messger t ungenau Skalierfaktor f r Fluid nicht korrekt Programm Modus ein geben Programmfaktor pr fen und r cksetzen Menge bersteigt Programm Wert f r Pulsverz gerung zu niedrig Programm Modus ein wert eingestellt geben Pulsverz gerung h her einstellen D LM OGP2Adv BA 89 1008 Garantie Seite 21 92 12 Garantie Badger Meter garantiert dass die Produkte frei von Defekten sind verursacht durch fehlerhaftes Material oder Arbeit f r einen Zeitraum von zw lf 12 Monaten vom Ver kaufsdatum des Produktes an den Endkunden die Garantiezeit VORAUSGESETZT DASS w hrend der Garantiezeit 1 Badger Meter erh lt eine Benachrichtigung mit allen Details des Defekts bei jedem Produkt und Details der Zeit und Ort des Kaufes des Produktes und 2 der Endkunde schickt das Ger t zur ck zu Badger Meter oder seinen n chsten Handelsvertreter auf seine Kosten Badger Meter kann wahlweise das durch Pr fung f r defekt befundene Produkt reparie ren oder ersetzen oder den vom Endkunden
37. Sie das Sperr ventil 2 Durch ffnen des r Messger te s s mtliches Fluid das sich im System befindet in einen Auffangbeh lter abfliessen lassen 3 S mtliche Luftventile und Fluidmessgerat e im System ffnen 4 Das die Messger t e ge ffnet lassen bis Sie soweit sind das System zu beauf schlagen Ger t unter Druck Das Ger t steht unter Druck bis der Druck manuell abgelassen wird Um die Verletzungsgefahr durch Fluidspritzer aus dem Messger t zu reduzieren bitte das Verfahren zur Druckreduzierung befolgen sobald Sie e angewiesen werden den Druck zu reduzieren e die Messung stoppen e irgendwelche Systemkomponenten pr fen reinigen oder warten D sen reinigen oder installieren Erdung 1 Durch Erdung wird die Gefahr der elektrostatischen Aufladung reduziert Alle Sys temkomponenten gem ss Ihren rtlichen landes und bundesstaatlichen Be stimmungen erden Hierf r auch die Pumpenbedienungsanleitung und Bedienungs anleitungen f r andere Systemkomponenten lesen um die Erdung bei folgenden Teilen durchf hren zu k nnen Pumpe Richten Sie sich nach den Empfehlungen des Herstellers Luft und Fluidschl uche Nur geerdete Schl uche verwenden Luftkompressor Richten Sie sich nach den Empfehlungen des Herstellers Fluid Zufuhrbeh lter Ortliche Richtlinien befolgen Explosion und Brandgefahr Sobald Fluid durch das Leitungssystem fliesst entsteht eine statische Aufladung Bei statischer Auflad
38. TAL pour modifier le Attention Toutes les positions entre 0 et 9 a l exception de la premiere sont visualisables Celle ci n est visualisable que pour les positions de 0 a 1 Ecran facteur de cadrage etde 140 3 Appuyer sur la touche RESET pour passer la prochaine valeur du facteur de cadrage 4 R p ter les tapes 2 et 3 pour les 5 positions du facteur de cadrage M morisation de modifications Pour sauvegarder les modifications et sortir du mode de programmation 1 Tenir appuy es simultan ment les touches TOTAL et Mm 2 L affichage clignote 3 fois et disparait 3 Appuyer sur la touche reset et l affichage se rallume Validation de modifications 1 Valider l unit de mesure 2 Appuyer simultan ment et en continu sur les touches Somme et Auto pour valider le facteur de cadrage D LM_OGP2Adv_BA 89 1008 Calcul du facteur de cadrage Page 59 92 10 Calcul du facteur de cadrage La notion facteur de cadrage est une valeur utilis e pour le calage de pr cision du compteur Le facteur de cadrage est param tr en usine prenant en r f rence une huile moteur avec un facteur de viscosit de 10W La raison principale d un reparam trage du facteur de cadrage est li e a l utilisation de fluides avec des viscosit s diff rentes Lorsqu un fluide a une viscosit trop faible il peut y avoir une circulation de fluide dans le bloc moteur qui n est pas mesur e En modifiant le facteur de cadrage il e
39. a entrada del modo de programaci n Localizaci n del orificio de acceso para la tecla de Programaci n PROGRAMMING 9 2 Cambiar la unidad de medici n El medidor viene con una opci n de seleccionar 4 unidades de medici n distintas D gitos del Factor de 1 La unidad de medici n actual est parpadeando cuando se ingresa al modo de programaci n D WE 2 Presione el bot n TOTAL ara alternar entre las cuatro opciones PT QT GAL L Unidad de medici n 3 Cuando la unidad de medici n deseada est Pantalla de programaci n desplegada presione el bot n mes La unidad de medici n dejar de parpadear 4 Si L litros es seleccionada el punto decimal empieza a parpadear Ahora tiene la opci n de cambiar el punto decimal por un punto o coma Para hacerlo presione el bot n TOTAL 5 Si no se requieren cambios en el factor de escala vaya a guardar los cambios 9 4 3 LM_OGP2Adv_BA_89_1008 Cambiar la configuraci n de f brica p gina 81 92 9 3 9 4 9 5 Cambiando la unidad de medici n de m trico a inglesas o de inglesas a m trico se borrar n el total reiniciable y el total acumulado Cambio del factor de escala Cambiando el factor de escala cambia la precisi n del medidor causando potencialmente un sobrellenado o un llenado incompleto Esto tiene el potencial de causar una aver a mec nica D gitos del Factor de S S Ra 1 Presione el bot n mp para avanzar a trav
40. aktor nicht den auf der Ausl se vorrichtung genannten verwenden gt LM_OGP2Adv_BA_89_ 1008 Skalierfaktor berechnen Seite 15 92 Diagramm der ungef hren Skalierfaktoren f r Fluide mit unterschiedlicher Viskosit t Skalierfaktor 1 08 1 07 1 06 Skalierfaktor 1 01 1 00 0 99 ste CH CD CU zz ES ERR 10 100 1000 10000 Viskositat in Zentistokes bei 65 Beispiele f r Fluide Viskosit t und Skalierfaktoren Fluid Viskositat Skalierfaktor 1 Wasser kaltebestandig 5 1 044 2 Frostschutzmittel 18 1 007 3 Bremsfl ssigkeit 42 1 004 4 ATF 80 1 002 5 10W 140 1 000 6 80W 90 450 0 999 7 140W 1800 0 993 gt LM_OGP2Adv_BA_89_ 1008 Skalierfaktor berechnen Seite 16 92 11 0 SPEZIFIKATIONEN Englisch Metrisch Max Durchflussmenge 10 gpm 38 l min Min Durchflussmenge 0 25 gpm 1 l min Max Betriebsdruck 1000 psi 67 bar Min Betriebsdruck 5 psi 0 35 bar Max Betriebstemperatur 120 F 50 C Min Betriebstemperatur 20 F 5 C Genauigkeit le 0 5 0 5 Genauigkeit Frostschutzmittel 1 5 1 5 5 stelliges LCD Display Quarts Pints Gallone Liter Anschl sse Ein und Ausgang Ve NPT Ve BSPP 3 LM_OGP2Adv_BA_89_1008 Skalierfaktor berechnen Seite 17 92 Teil Nr Teilebeschreibung Teile Nummer von BMI Teile Nummer von BME 1 Batteriehalterung 641
41. ar gemacht werden f r Sch den die bei Anwendung oder Gebrauch des beschriebenen Ger tes entstehen Wird dieses Messger t in einer anderen als der von Badger Meter Inc genannten Art und Weise verwendet kann der f r dieses Messger t gebotene Schutz beeintr chtigt werden und die Garantie wird ung ltig 2 Warnhinweise 2 1 Explosion sowie Brandgefahr Durch falsche Erdung zu geringe Bel ftung offene Flammen oder Funken kann eine gef hrliche Situation entstehen die zu einer Explosion bzw einem Brand f hren kann die schwere Verletzungen nach sich ziehen k nnen e Stellen Sie sicher dass das Fluidsystem richtig geerdet ist F r n here Einzelheiten bitte auch die Pumpenbedienungsanleitung durchlesen Bei elektrostatischer Aufladung bzw falls Sie bei Benutzung des Messger tes einen elektrischen Schlag erleiden Zuleitung sofort einstellen Problem ermitteln und beheben bevor Sie mit der Bedienung fortfahren e F r Frischluftzirkulation sorgen dadurch kann verhindert werden dass sich D mpfe aus dem abgegebenen Fluid bilden e W hrend der Fluidzufuhr nicht rauchen e Zuleitungsbereich frei von Abf llen L semittel Putzlumpen und versch ttetem Benzin halten 2 2 Gefahren f r den Z hler Unsachgem er Gebrauch kann zu Bruch des Messger tes bzw Fehlfunktionen f hren und schwere Verletzungen verursachen e Dieses Ger t ist nur f r den professionellen Gebrauch Alle Hinweise Schilder und Aufkleber vor Ge
42. brauch des Ger tes lesen Ger t nur f r den genannten Verwendungszweck einsetzen An dem Ger t KEINERLEI Anderungen vornehmen Ger t NICHT unbeaufsichtigt w hrend des Messvorgangs lassen Ger t t glich pr fen Verschlissene oder besch digte Teile reparieren bzw sofort austauschen e Genannten max Arbeitsdruck f r das Teil mit der niedrigsten Nennleistung im System NICHT berschreiten e Nur Verl ngerungen und Ausl ufe die f r den Gebrauch dieses Ger tes konstruiert wurden verwenden e Nur Fluide und L semittel die mit dem Ger t kompatibel sind verwenden Alle Warnhinweise des Lieferanten ber Fluid und L semittel lesen e Alle Fluidverbindungen vor Betrieb des Ger tes fest anziehen e Undichte Stellen abdichten bzw bei Undichtheit Fluid oder L semittel nicht von Hand mit dem K rper Handschuhen oder Lappen ableiten gt LM_OGP2Adv_BA_89_ 1008 Warnhinweise Seite 2 92 e Nicht in Richtung auf eine Person oder ein K rperteil leiten e Nicht mit Ihren H nden oder Fingern ber das Messventilende hinausfassen bzw nicht in dieses hineingreifen e Alle rtlichen landes und bundesstaatlichen Feuer elektrischen und Sicherheits bestimmungen beachten e Wird dieses Produkt in einer anderen als in dieser Bedienungsanleitung genannten Weise verwendet kann dies zu einer Beeintr chtigung der Funktion oder zu Sch den am Ger t f hren Dieses Messger t ist speziell f r die Messung von lprodukten kon
43. ccumulated totals sense een nnnnnennennnnnnnnen nennen ennennnn 30 7 2 Emergency override uu ia aaa ie aiaa AESA EE TaT Eae 31 Re H el 31 7 4 le EE 31 Los HEES res vas sean veteiecarteet tit 32 A A nement inde Lee es bo nnNi ra tane 32 Bull LOW E RTE 32 8 2 Changing the batteries ss 32 9 Change factory Steen dege ee lens dati eee EENEG 33 9 1 dree lecher lee BEE 33 9 2 Change unit for measure nen 33 9 3 Change scale factor nenn 34 E De Ee 34 9 5 Verifvchanges nenn 34 3 LM_OGP2Adv_BA_89_1008 Contents page 23 95 10 Calculate scale factor su seen ae aa 35 10 1 Absolute scale factor 35 ATs Troubleshooting ac een 41 LK EI A seen hear han en Keane tonasaatantainteniisiesesenccnadsatestsnaciamanteans 42 13 Manufacturer s declaration 90 E Wl Ren 91 3 LM_OGP2Adv_BA_89_1008 Disclaimer Warning page 24 92 1 Disclaimer The user purchaser is expected to read and understand the information provided in this manual follow any listed safety precautions and instructions and keep this manual with the equipment for future reference The information in this manual has been carefully checked and is believed to be entirely reliable and consistent with the product described However no responsibility is assumed for inaccuracies nor does Badger Meter Inc assume any liability arising out of the application and use of the equipment described Should the equipment be used in a manner not specified by Badger Meter I
44. cy override In case of an emergency or to interrupt a batch the meter is equipped with an emergency override 1 Press the red button on the meter to activate the emergency override The override closes the valve immediately stopping fluid flow 2 After an emergency override batching can continue by pulling up on the trigger History This option allows the user to review the previous five 5 batches dispensed with the meter 1 Press and hold the 10 HISTORY button to view the five 5 previous batches The batches are displayed on screen one at a time 1 d QT beginning with the most recent and cycling through to the oldest HISTORY 3 e The batches continue to cycle as long as the history button is held down History option 2 Two 2 seconds after releasing the history button the display automatically returns to the normal operating screen NOTE The HISTORY cannot be erased unless the user changes from English to metric or from metric to English units see change factory settings under 9 1 Flow rate This option allows a user to see instantaneously the rate at which fluid is flowing through the meter Press and hold the FLOW RATE button while fluid is flowing through the meter The flow rate appears in the bottom right hand corner of the display e As long as the button is held down the flow rate A ar remains on the display cpu e Releasing the button returns the display to the norma
45. da y salida del pivote son de 1 2 NPT o 1 2 BSPP dependiendo del modelo del medidor En el lado opuesto aplique sellador a la terminal de la boquilla El sellador recomendado es Loctite 243 Enrosque la boquilla al medidor Atornille ajustadamente con una llave ajustable Abra todas las v lvulas de cierre de las posiciones de dosificaci n Inicie el bombeo para presurizar el sistema Antes de usar aseg rese de la precisi n purgue todo el aire de las l neas del fluido y v lvulas dosificadoras Coloque la boquilla 3 LM_OGP2Adv_BA_89_1008 Operaci n del Medidor p gina 74 92 6 Operaci n del Medidor NOTA El bot n del teclado AUTO es empleado para alternar entre el modo Manual y el modo Autom tico de dosificaci n 6 1 Modo Manual En el modo manual el medidor opera de forma libre en la dosificaci n del fluido a trav s del mango QT HE 1 Jale el gatillo para iniciar el flujo 2 La pantalla muestra la cantidad de flujo dosificado 3 Cuando la cantidad deseada de flujo haya sido dosificada libere el gatillo para detener el flujo 4 Presione el bot n reser Una vez para reiniciar el Modo Manual contador a cero 6 2 Modo autom tico de dosificaci n Para ingresar al modo de programaci n de dosificaci n autom tica presione el bot n auto hasta que aparezcan un d gito y dos puntos Aparece esta pantalla El medidor ahora est listo para la selecci n del n mero or
46. der Nachweis erbracht dass die Forderungen der ISO 9001 2000 erf llt sind Dieses Zertifikat ist g ltig bis 2011 02 13 Zertifikat Registrier Nr 12 100 24674 TMS ka ol SS on CERTIFICATE M nchen 2008 02 16 ZERTIFIKAT RUE a T V S D Management Service GmbH Zertifizierstelle Ridlarstra e 65 80339 M nchen Garmany TOV D LM_OGP2Adv_BA_89 1008 DIN ISO Zertifikat Certificate Certificat Certificado 92 92 CERTIFICATE The Certification Body of T V S D Management Service GmbH certifies that Badger Meter Europa GmbH N rtinger Strasse 76 D 72639 Neuffen has established and applies a Quality Management System for lt ra gt er LL o 0 o x o re ce uy Rh XL Se e gt a HA a 4 Flowmetering and Control Design Selling and Production ail Ai os ots An audit was performed Report No 70002816 Proof has been furnished that the requirements according to ISO 9001 2000 are fulfilled The certificate is valid until 2011 02 13 Certificate Registration No 12 100 24674 TMS NT ED Munich 2008 02 16 QMS TGA ZM 07 32 CERTIFICATE ZERTIFIKAT e T V S D Management Service GmbH e Zertifisierstelle RidlerstraGe 65 80339 Minchen Germany TOV D LM_OGP2Adv_BA_89 1008 Hotline Bei technischen Fragen kontaktieren Sie bitte Ihren H ndler bzw Lieferanten Please contact your supplier for any t
47. e programmed batch Count down arrow amount down to zero Batch number 3 is always in the 4 d y count down mode 2 Press the aura button to lock in the batch quantity when batch size is selected The screen flashes and the batch number icon no longer displays QT 4H e If the meter is in count up mode the display shows zeros 45 Count up mode 450 LI e If the meter is in the count down mode the desired batch size appears on the screen E Count down mode 7 Operating mode functions These functions operate the same in manual mode and auto batch mode 7 1 Resettable accumulated totals 1 To see the accumulated total and the resettable total e Press and hold the TOTAL outton to see the accumulated total e Continue holding the TOTAL 2utton After three seconds the screen changes to the resettable total 2 Reset total displays the total fluid dispensed since i d L the resettable total was last set back to zero Press the RESET button while viewin eset total to es SP th butt hile viewing Reset total t set it back to zero 4 Release the mu button to return to the operating screen 3 LM_OGP2Adv_BA_89_1008 Operating mode functions page 31 92 7 2 7 3 7 4 NOTE The accumulated total cannot be reset unless the user changes from English units to metric units or from metric to English units see change factory settings change unit of measure under 9 2 Emergen
48. e r duction de pression e D avis d arr t des mesures De v rification de nettoyage ou de maintenance de l un des composants du syst me e De nettoyage ou d installation d embo ts Mise a la terre 1 La mise la terre r duit les risques de surcharge lectrostatique Mettre tous les composants du systeme la masse selon les dispositions locales territoriales et nationales Lire galement le mode d emploi des pompes et les notices d utilisation des autres composants du syst me afin d effectuer la mise amp la terre des pi ces suivantes Pompe respecter les recommandations du fabricant Tuyaux flexibles air et fluide n utiliser que des tuyaux flexibles reli s A la terre Compresseur d air respecter les recommandations du fabricant R servoir d alimentation en fluide respecter les directives locales Explosion et risque d incendie Tout passage de fluide dans les conduites systeme engendre une surcharge lectrostatique Une surcharge lectrostatique peut provoquer des tincelles pouvant engendrer une explosion et un incendie Les conduites du syst me doivent tre mises la terre OPO OD Rincage Attention Lorsque le syst me est compos de plusieurs points de mesure proc der depuis le point le plus loign de la pompe et progresser en direction de celle ci 1 Fermer tous les niveaux de la vanne de mesure de fluide 2 L ouverture de la soupape dar n est possible que lorsque la va
49. echnical assistance you may need Pour toutes questions techniques veuillez prendre contact avec votre revendeur ou votre fournisseur Para soporte t cnico por favor contacte a su proveedor o distribuidor Badger Meter Europa GmbH Subsidiary of Badger Meter Inc USA N rtinger Str 76 72639 Neuffen Germany E mail badger badgermeter de www badgermeter de
50. ede continuar jalando el gatillo Historial Esta opci n permite al usuario revisar las ltimas cinco 5 dosificaciones realizadas con el medidor 1 Presione y mantenga presionado el bot n wu HISTORY para visualizar las cinco 5 dosificaciones anteriores e Las dosificaciones son desplegadas en la pantalla Lf d QT una a la vez iniciando con la mas reciente y e cambiando hasta la m s antigua HISTORY e Las dosificaciones contin an cambi ndose mientras 3 que el bot n del historial se mantenga presionado Opcion de historial 2 Dos 2 segundos despu s de haber liberado el bot n del historial la pantalla regresa auto maticamente a la pantalla de operaci n normal NOTA El HISTORIAL no puede ser borrado a menos que el usuario cambio de unidades inglesas a m tricas o viceversa v ase cambio de configuraci n de fabrica 3 LM_OGP2Adv_BA_89_1008 Funciones del Modo de Operaci n p gina 78 92 7 4 7 5 Rango de flujo Esta opci n permite al usuario visualizar de manera instant nea el flujo del fluido mientras pasa por el medidor Presione y mantenga presionado el bot n 1 LOW RATE mientras que el fluido esta pasando por el medidor El rango de flujo aparecera en la esquina inferior derecha de la pantalla e Mientras se mantenga presionado el bot n el flujo p a permanecera en la pantalla e Al dejar de presionar el bot n la pantalla regresar a AUTO rn e 7 la pantalla de operaci n normal
51. eil de mesure pour les mesures suivantes Remise z ro de la somme mise en m moire par la touche de somme pendant la prise de mesures Reset D connection ou arr t O Stoppe le passage 4 Ecran LCD 1 2 1 Indique la somme mise en m moire la valeur mesur e et le facteur de cadrage 2 Indique l unite de mesure L ar 3 3 Fl ches avant arri re pour comptage croissant et d croissant TOY Lemma A 4 Pr s lection de la quantite 2 5 Symbole pour d roulement de la prise de mesure B BB H 6 AUTO indique que le mode EPM est actif R ER 7 Symbole pour batterie faible 7 6 5 4 7 LCD Display LCD Display Y LM_OGP2Adv_BA_89_1008 Montage de l appareil Page 48 92 5 Montage de l appareil 5 1 5 2 5 3 R duction pression syst me 1 Couper l alimentation lectrique de la pompe et fermer la vanne de coupure 2 Vidanger l appareil de mesure et laisser s couler dans un bac de r cup ration tout le fluide se trouvant dans le syst me 3 Ouvrir toutes les soupapes d air et les appareils de mesure de fluide du syst me 4 Laisser l les appareil s de mesure ouvert s jusqu ce vous soyez en mesure de mettre en charge le syst me Appareil sous pression L appareil est sous pression jusqu d pressurisation manuel du syst me Pour r duire les risques de blessures par projection de fluide hors de lappareil appliquer la proc dure de r duction de pression en cas e D avis d
52. ely with an open ended adjustable wrench NOTE The threaded end of the meter always has female threads The metal end of the hose must have male threads Apply thread sealant Loctite 243 or equivalent to the male end The inlet and outlet swivel connections are either 1 2 NPT or 1 2 BSPP depending on meter model 1 On the opposite end apply sealant to the end of the nozzle Recommended sealant is Loctite 243 2 Thread the nozzle onto the meter Screw it in tightly with an open ended adjustable wrench _ 3 Open all dispense position shut off valves Start the pump to pressurize the system 4 Before use to ensure accuracy purge all air from the fluid lines and dispense valve s LM_OGP2Adv_BA_89_ 1008 Meter operation 6 Meter operation NOTE The keypad Auto button Mode 6 1 Manual mode uu e Manual mode 6 2 Auto batch mode page 28 92 is used to toggle between Manual Mode and Auto Batch In the manual mode the meter operates as a free flow dispensing handle s Pull the trigger to begin the flow The display shows the amount dispensed When the desired amount has been dispensed release the trigger to stop the flow Press wer button once to reset the counter display to zero To enter the auto batch programming mode press the AUTO gt button until a digit and colon appear This screen appears uuu D Auto batch program mode The meter
53. en todas las posiciones Una vez que la valvula principal de salida del fluido esta cerrada y la presi n del aire al motor de la bomba esta apropiadamente ajustada la valvula de aire es abierta Abra lentamente la valvula principal del fluido que la manguera esta asegurada para que no haya fugas del liquido durante el proceso de enjuagado Abra lentamente la valvula de dosificaci n y permita que una cantidad generosa de fluido pase a trav s de sta para asegurar que el sistema esta limpio Cierre la valvula y repita los pasos para todas las posiciones de dosificaci n Si esta es una instalaci n nueva o si el fluido en las lineas esta contaminado enjuague el sistema antes de instalar el los medidor es 3 LM_OGP2Adv_BA_89_1008 Instalaci n del Medidor 5 4 5 5 p gina 73 92 Colocaci n del medidor a la manguera Cierre la v lvula de drenado antes de iniciar este procedimiento Coloque la manguera Colocaci n de la boquilla al medidor 1 Coloque el pivote giratorio al medidor Aplique sellador a la rosca macho de la manguera El sellador recomendado es Loctite 243 Inserte la terminal met lica de la manguera en el pivote Apriete completamente con una llave ajustable NOTA La terminal roscada del medidor siempre tiene roscas hembras La terminal met lica de la manguera debe tener rosca macho Aplique sellador a la rosca macho Loctite 243 o equivalente Las conexiones de entra
54. er perjudicada y la garantia anulada 2 Advertencia 2 1 Riesgos de Incendio y Explosi n Conexi n a tierra inadecuada la mala ventilaci n llamas o chispas pueden causar una condici n peligrosa y provocar una explosi n o incendio y causar lesiones graves Aseg rese que el sistema est aterrizado apropiadamente Consulte el manual de instrucciones la bomba para detalles Si existe carga est tica o si siente una descarga el ctrica mientras usa el medidor pare inmediatamente la dosificaci n Identifique y corrija el problema antes de continuar Proporcione una ventilaci n de aire fresco Esto evitar la acumulaci n de vapores del l quido que se est dosificando No fumar mientras se dosifican l quidos inflamables Mantenga el rea de dosificaci n libre de residuos incluidos los disolventes trapos y derrames de gasolina 2 2 Riegos del Medidor El uso indebido del equipo puede causar la ruptura del medidor o el mal funcionamiento del mismo y causar severos da os Este equipo es para uso profesional exclusivamente Lea todas las instrucciones y etiquetas antes de operar el equipo Utilice el equipo s lo para su finalidad prevista NO modificar o alterar el equipo NO deje el equipo desatendido mientras se realiza la dosificaci n Revise el equipo diariamente Repare o reemplace las piezas da adas o desgastadas de inmediato NO exceda el nivel m ximo de presi n de trabajo del componente m s bajo del sistema
55. erm e interrompant le passage de fluide 2 Apr s activation du bouton manuel d arr t d urgence la prise de mesure peut continuer en activant la g chette D LM_OGP2Adv_BA_89_1008 Fonctions op rationnelles Page 55 92 7 3 7 4 7 5 D roulement Cette option permet l utilisateur de v rifier les 5 derni res quantit s mesur es par l appareil 1 Appuyer sur la touche HISTORY W et la maintenir enfonc e pour faire appara tre les 5 quantit s pr c dentes Les quantit s sont affich es l une apr s l autre La derni re quantit s affiche en premier respec Uu d QT tivement jusqu a la plus ancienne HISTORY Les quantit s sont successivement affich es tant 3 que la touche m moire est enfonc e e 2 Deux secondes apr s rel chement de la touche Option d roulement HISTORY l cran passe automatiquement a l affichage de service Attention Le d roulement ne s efface que lorsque l utilisateur permute des unit s metriques aux unites anglaises ou inversement cf modification parametres usine au point 9 1 Debit Cette option permet a Putilisateur de visualiser imm diatement la quantit d bit e dans l appareil de mesure e En appuyant sur la touche M JFLOW RATE durant le passage du fluide dans l appareil de mesure le d bit s affiche en temps r el dans l angle inf rieur droit de l cran el or e Tant que cette touche reste enfonc e le d bit reste affich a l cran
56. es fonctionnent parfaitement Caract ristique Cause ventuelle Mesure de correction Affichage symbole batterie Batteries faibles Changer les piles Ecran noir Appareil au repos Appuyer sur la touche Reset Enlever les piles et v rifier les Mauvais contact piles contacts Appuyer sur la touche Reset Changer les piles Appuyer Batteries vides sur la touche Reset u Appuyer sur la touche AUTO nn n effectue pas le L appareil n est pas en mode Auto et programmer l unit de atching GE Remise a zero non effectu e Appuyer sur latouche RESET V rifier le symbole batterie Batteries faibles Changer les piles Appuyer sur la touche RESET Le fluide s coule lentement ou pas du tout Filtre bouch Nettoyer et ou changer le filtre Pression pompe trop faible Augmenter la pression pompe Corps trangers bouchent l appareil Contacter de mesure revendeur fournisseur sur place Precision de l appareil Facteur de cadrage incorrect pour le Entrer dans le mode insuffisant fluide Programme v rifier le facteur de programme et r initialiser Ser Entrer dans le mode La quantit exc de la La valeur de temporisation Programme r gler la valeur valeur programm e d impulsion r gl e est trop faible de temporisation d impulsion une valeur sup rieure D LM_OGP2Adv_BA 89 1008 Garantie Page 66 92 12 Garantie La soci t Badger Meter Inc se porte garante que ses produits sont exe
57. eur de cadrage de r f rence est de 1 0123 comme indiqu ci dessus dans Affichage du facteur de cadrage actuel 5 Calculer le nouveau facteur 1 0123 facteur de cadrage de r f rence X 1 05 coefficient d erreur 1 0629 nouveau facteur de cadrage 6 Saisir ce facteur comme d crit dans le chapitre Facteur de cadrage Attention Utiliser le facteur de cadrage affich sur l cran et non celui inscrit sur la g chette D LM_OGP2Adv_BA 89 1008 Calcul du facteur de cadrage Facteur de cadrage Page 60 92 Diagramme des valeurs approchantes des facteurs de cadrage pour les fluides de diff rentes viscosit s 1 08 1 07 1 06 1 00 0 99 0 98 10 Facteur de cadrage 100 1000 10000 Viscosit pour Zentistokes a 65 Exemples de fluides viscosit et facteur de cadrage Fluide Viscosit Facteur de cadrage 1 Eau r sistant au froid 5 1 044 2 Produit antigel 18 1 007 3 Liquide de frein 42 1 004 4 ATF 80 1 002 5 10W 140 1 000 6 80W 90 450 0 999 7 140W 1800 0 993 3 LM_OGP2Adv_BA_89_1008 Calcul du facteur de cadrage Page 61 92 11 0 SPECIFICATIONS Anglaise Metrique Debit maxi 10 gpm 38 l min Debit mini 0 25 gom 1 l min Pression d utilisation maxi 1000 psi 67 bar Pression d utilisation mini 5 psi 0 35 bar Temp rature d utilisation maxi 120 F 50 C
58. eur de respecter les lois et r glements en vigueur r gissant la vente de ces produits D LM_OGP2Adv_BA 89 1008 Indice Page 67 92 5 FEFMINOS e Ten 69 E SE ED TD TR DO ER I ne 69 2 1 Riesgos de Incendio y Explosi n nun 69 2 2 Riegos del Medidor oreren errira EE EE EEEE E E A 69 Botones delMedidor insiacinunn naar nnne 70 Pantalla LED aras 71 Instalaci n del Medidor 71 5 1 Liberar la presi n en el Sistema as ae na 71 5 2 Aterrizaje iii 71 5 3 Procedimiento de enjuagado 72 5 4 Colocaci n del medidor a la manguerg eee 73 5 5 Colocaci n de la boquilla al meddor rneer eee 73 Operaci n del Medid O Fusion nee 74 6 1 Modo M nual 2 3 see cn nn ta cuts unten et 74 6 2 Modo autom tico de dosificaci n ooonoooncccnnnnccccnnononononnnnnccnonananononnnnnnnnnnnnnnnanonnnnnos 74 6 3 Modos de conteo Creciente Decreciente oooccccccccconcnonocononcnonononanononenononananancninnnnnns 76 Funciones del Modo de Operaci n sssnnnrs 77 7 1 Totales Reiniciables Acumulados ccccccccccniciniconinennnennnnnnnennnennnennnennnnnnnnnnnnnnnninnniss 77 7 2 Anulaci n de emergencia seini see ne 77 A ER 77 7 4 Rango de flujo seeeseeeeeeeneeene tenne ennet rnern retn nern AEAEE EEEE EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE EEEE E EEEE EEEE 78 Lo C digos d rror ns Ei 78 E II A een 79 Seay EN TE E E SEE IELE E 79 82 Gargando las batea
59. f r dieses Produkt bezahlten Preis erset zen Die Haftung von Badger Meter und die Rechte des Endkunden innerhalb dieser Garantie k nnen begrenzt werden auf Reparatur Ersatz oder R ckerstattung und insbesondere nicht erweitert werden auf eine direkte spezielle indirekte oder daraus folgende Sch digung oder Verluste jeder Art Anmerkung Diese Garantie stellt weder den Bestandteil eines Vertrages dar noch bildet sie einen Vertrag zwischen Badger Meter und dem Endkunden Sie ist zus tzlich zu jeder Garantie die der Verk ufer der Produkte vorgegeben hat und schliesst nicht aus begrenzt schr nkt ein oder ver ndert die Rechte und Rechtsmittel die dem Endkunden verliehen wurden oder die Haftung die dem Verk ufer auferlegt wurde durch irgendeine Satzung oder Gesetz in Bezug auf den Verkauf des Produktes gt LM_OGP2Adv_BA_89_ 1008 Contents page 22 95 N E E e 24 2 WAL PING ni aia 24 2 1 Explosion and fire hazards nenn 24 2 2 Meter haz rds 5 222 O eege a Ed Ed 24 3 Meter EHNEN 25 7a Eh E e D Ro ETa F D E ici 25 9 Meter installation ee es 26 5 1 Relieve system pressure iii 26 AE ee ne EEN 26 5 3 Flushing procedure sie 26 5 4 Apply met r to hose seele heben 27 5 5 Apply nozzle to Meter cinco em ENEE KEEN EREECHEN 27 6 Meter oDera MON 28 A E E ek Ad aie ee Ai Ri RRA RS 28 6 2 Auto batch mode EE 28 6 3 Count up count down modes ss 29 7 Operating mode functions ner 30 7 1 Resettable a
60. gelten sowohl f r manuellen wie auch den Auto Batch Modus 7 1 R cksetzbare aufgelaufene Summen 1 Um aufgelaufene und r cksetzbare Summe anzuzeigen e Dr cken und halten Sie die TOTAL Taste um sich aufgelaufene Summen anzeigen zu lassen e Halten Sie die Tora Taste weiter gedr ckt Nach 3 Sekunden wechselt die Anzeige auf die r cksetzbare Summe cd 3 RESETTOTAL R cksetzbare Summe Die Resettotal Anzeige zeigt die gesamte Menge an Fluid an seit dem Zeitpunkt als die Resettotal Anzeige zum letzten Mal auf Null gesetzt wurde Dr cken Sie die RESET Taste um w hrend Sie Resettotal anschauen die Anzeige wieder auf Null zu setzen Lassen Sie die totat Taste los um wieder zur Betriebsanzeige zu gelangen Beachte Die aufgelaufene Summe kann erst dann zur ckgesetzt werden wenn der Bediener von den englischen zu metrischen oder von metrischen zu englischen Einheiten wechselt s Werkseinstellungen Masseinheiten ndern unter 9 2 gt LM_OGP2Adv_BA_89_ 1008 Betriebsfunktionen Seite 10 92 7 2 7 3 7 4 Hand Notbet tigung F r den Notfall oder um eine Messvorgang zu unterbrechen ist das Messger t mit einer Hand Notbet tigung ausger stet 1 Die rote O Taste am Messger t dr cken um die Hand Notbet tigung zu aktivieren Dadurch wird das Ventil geschlossen und es fliesst kein Fluid mehr durch 2 Nach einer Hand Notbet tigung kann mit der Messung durch Ziehen der
61. ias sin carga Reemplace las baterias Presione el bot n reset El medidor no se asegura El medidor no est en modo AUTO Presione AUTO y programe para dosificar el tama o de dosificaci n Medidor no reiniciado antes de Presione el bot n RESET la siguiente dosificaci n Bater as bajas Verifique cono de bater as reemplace bater as Presione el bot n RESET Flujo lento o sin flujo El filtro est tapado Limpie o reemplace el filtro del pivote La presi n de la bomba es baja Suba la presi n de la bomba Material externo est atascando el Contacte a su distribuidor medidor local para reparaci n Medidor impreciso Factor de escala incorrecto para Ingrese a modo el fluido programaci n verifique y reinicie el factor programado Dosificaci n anula valor de Valor del pulso de retardo muy bajo Ingrese a modo programaci n programaci n e incremente el valor programaci n 3 LM_OGP2Adv_BA_89_ 1008 Garantia p gina 89 92 12 Garantia Badger Meter garantiza que los medidores y partes fabricadas y suministradas se encuentran libres de defectos en los materiales y mano de obra por un periodo de doce 12 meses de la fecha de venta al usuario final el periodo de garantia SIEMPRE QUE durante el periodo de garantia 1 Badger Meter reciba notificaci n en donde se detalle por complete cualquier defecto en el producto y detalles del tiempo y lugar de compra del producto y 2 El usuario final retorne el producto a
62. idades gt e Presione el bot n 0 1 para incrementar la cantidad de dosificaci n en 1 unidad Modo de programaci n automatica de dosificaci n opci n 3 cono NOTA V ase la especificaci n del modo de Conteo Creciente Decreciente 6 3 3 Despu s de que el tama o de la dosificaci n es seleccionada presione el bot n auto Para fijar la dosificaci n y despachar el fluido 4 Jale el gatillo para iniciar el flujo La Tama ode v lvula solenoide en el medidor Autom tico TNT or a o autom ticamente asegura la v lvula UUU A automation dosificadora en una posici n ES completamente abierta Ms AACAUTION El medidor siempre se asegura en la posici n de m xima apertura 5 Libere el gatillo permiti ndole retraerse 6 El flujo autom ticamente se detiene cuando la cantidad ha sido dosificada 7 Despu s que la cantidad de la dosificaci n ha sido despachada el medidor est en un modo libre de dosificaci n a trav s del mango hasta que el bot n de reiniciar ha sido presionado NOTA En el caso de una emergencia o en la interrupci n de una dosificaci n el medidor est equipado con una anulaci n de emergencia v ase Anulaci n de emergencia 7 2 8 El usuario tiene la opci n completar el fluido al t rmino de una dosificaci n Para completar el fluido jale el gatillo para iniciar el flujo y libere cuando la cantidad deseada ha sido bombeada 9 Presione el bot n RESET ido haya termi
63. kalierfaktor zu springen 4 Die Schritte 2 und 3 bei allen f nf Stellen im Skalierfaktor wiederholen 9 4 nderungen speichern Um nderungen zu speichern und den Programmiermodus zu verlassen 1 TOTAL und avto Tasten gleichzeitig gedr ckt halten 2 Die Anzeige blinkt 3 Mal und verschwindet 2 reset Taste dr cken Das Display ist wieder an 9 5 nderungen pr fen 1 Pr fen ob Masseinheit korrekt ist 2 Summen und Auto Tasten gleichzeitig dr cken und halten um zu pr fen ob der Skalierfaktor stimmt 10 Skalierfaktor berechnen Unter Skalierfaktor versteht man eine Zahl die f r die Genauigkeit des Messger tes verwendet wird Der Skalierfaktor wird werksseitig eingestellt wobei von Motoren l mit einer Viskosit t von 10W ausgegangen wird Der h ufigste Grund f r eine Neueinstellung des Skalierfaktors ist die Verwendung von Fluiden mit unterschiedlicher Viskosit t Hat das Fluid eine geringere Viskosit t kann mehr Fluid durch die Motorgetriebe fliessen ohne erfasst zu werden Durch eine Anderung des Skalierfaktors kann der Verlust ausgeglichen werden gt LM_OGP2Adv_BA_89_ 1008 Skalierfaktor berechnen Seite 14 92 Das Messger t multipliziert jeden Impuls mit der Skalierfaktornummer um die Genauigkeit zu korrigieren wenn es ihn in die spezifizierten Einheiten umrechnet Die Anzeige stimmt dann immer Was den ungef hren Skalierfaktor f r Fluide mit unterschiedlichen Viskosit ten angeht s
64. l 5 4 t operating screen Flow rate option NOTE The flow rate can only be displayed if fluid is flowing through the meter 3 LM_OGP2Adv_BA_89_1008 Service page 32 92 75 Error codes The meter has one error code that may display It provides an indication at the meter that there is an error in communication between the meter and keypad SFO scale factor 0 the scale factor setting for the meter is set to 0 000 e To input a valid scale factor for the meter follow the instructions in chapter 9 Change factory settings All other Error Codes are for factory purposes only To clear the meter press reset 8 Service 8 1 Low battery When the batteries need to be exchanged a progression of warnings appears on the meter screen First warning The low battery icon appears in the QT lower left corner of the display That means the batteries are low and need to be exchanged Second warning Battery icon flashes The battery power is too low and meter functions are disabled Dona battery icon 8 2 Changing the batteries The battery compartment is located in the lower case on the underside of the trigger guard 1 Turn the unit over 2 Unscrew the two screws Remove the battery door to expose the batteries 3 Replace the old batteries The meter takes 4 AA alkaline batteries NOTE Battery polarity markings are inside battery compartment 4 Dispose of used batteries properly according
65. les deux vis Enlever le c che pour acc der au compartiment des piles 3 Changer toutes les piles L appareil a besoin de piles de type 4 AA Alcaline Attention Le sens de polarit des piles est indiqu dans le compartiment des piles 4 Elimination des piles usag es selon les r glements nationaux ou locaux Attention Le changement de batterie n a pas d incidence sur les valeurs program m es ou sur les sommes Y LM_OGP2Adv_BA_89_1008 Modification des param tres usine Page 57 92 9 Modification des param tres usine Chaque appareil de mesure est param tr en usine en fonction de l huile moteur cf point 9 3 Modification facteur de cadrage L unit de mesure est galement s lectionn e en usine V rification de la version Firmware 1 Tenir appuy es simultan ment les deux touches TOTAL et 1 our afficher la version de l appareil et son code 2 Les deux derniers chiffres en bas a droite sont la version Firmware 3 Pour les compteurs avec une version 17 et plus veuillez lire 9 2 Modification unit s de mesure et 9 3 Modification facteur de cadrage 9 1 Programmation Modifier les param tres usine 1 Tenir appuy es simultan ment les touches TOTAL et AUTO PrG appara t sur l affichage Rel cher les touches TOTAL et AUTO 4 Appuyer puis rel cher les touches ci apres dans l ordre suivant gt tora C 10 u at Tora 5 La mesure d unit actuelle clignote Vous
66. mpts de d fauts lies un mat riel ou une op ration d fectueu et consent l utilisateur final une garantie pour une dur e de douze 12 mois partir de la date d achat du produit par l utilisateur final dur e de garantie aux conditions suivantes que pendant la dur e de garantie 1 soit transmis a la soci t Badger Meter les informations d taill es concernant le d faut pour chacun des produits ainsi que la date et le lieu d achat 2 Putilisateur final retourne a ses frais l appareil d fectueux a Badger Meter ou a son distributeur le plus proche Badger Meter se r serve le choix de r parer ou changer apr s contr le un appareil r put d fectueux ou restituer l utilisateur final le prix vers pour l acquisition dudit appareil La responsabilit de Badger Meter ainsi que les droits du client final sont limit s la r paration l change ou le remboursement pendant toute la p riode de garantie et ne peuvent en aucun cas tre largis de fa on directe indirecte ou sp cifique des dommages et des pertes induites Remarque Cette garantie na pas valeur de contrat et n tablit en aucune mani re un lien contractuel entre Badger Meter et son client final Elle est compl mentaire aux garanties et aux pr conisations dont le vendeur a assorti son produit et n exclut ne r duit ne limite et ne modifie en rien les droits et recours l gaux reconnus au client final ni la responsabilit incombant au vend
67. nado La pantalla se reiniciar y el medidor ahora est listo para la siguiente dosificaci n 3 LM_OGP2Adv_BA_89_1008 Operaci n del Medidor p gina 76 92 6 3 Modos de conteo creciente decreciente 1 Cuando se encuentre en el modo de programaci n autom tico presione el bot n RESET y las flechas de conteo creciente decreciente parpadee en la pantalla HH ma 45 Flecha de conteo creciente DD mm 45 Flecha de conteo decreciente Presione el bot n TOTAL para alternar ente el conteo creciente decreciente Presione el bot n reset para seleccionar el conteo creciente o el conteu uerreciente NOTA En la opci n de conteo creciente el medidor cuenta hasta la cantidad de dosificaci n programada En la opci n de conteo decreciente el medidor cuenta desde la cantidad de dosificaci n programada hasta cero El n mero de dosificaci n 3 est siempre en el modo de conteo decreciente 2 Presione el bot n am para asegurar la cantidad de dosificaci n cuando el tama o de la dosificaci n es seleccionado La pantalla parpadea y el cono num rico de la dosificaci n ya no ser desplegado nmr UM up Modo de conteo creciente MSO gt CS Modo de conteo decreciente e Si el medidor esta en modo de conteo creciente la pantalla mostrar ceros e Si el medidor esta en modo de conteo decreciente el tamano de la dosificaci n deseada aparecer en la pantalla
68. nc the protection provided by the equipment may be impaired and the warranty voided 2 Warning 2 1 Explosion and fire hazards Improper grounding poor ventilation open flames or sparks can cause a hazardous condition and result in an explosion or fire and cause serious injury Be sure the fluid system is properly grounded See your pump instruction manual for details If there is static sparking or if you feel an electric shock while using the meter stop dispensing immediately Identify and correct the problem before continuing Provide fresh air ventilation This will avoid the build up of fumes from the fluid being dispensed Do not smoke while dispensing flammable fluids Keep the dispensing area free of debris including solvents rags and spilled gasoline 2 2 Meter hazards Equipment misuse can cause the meter to rupture or malfunction and cause serious injury This equipment is for professional use only Read all instructions tags and labels before operating the equipment Use the equipment only for its intended purpose Do NOT modify or alter the equipment Do NOT leave equipment unattended while dispensing Check equipment daily Repair or replace worn or damaged parts immediately Do NOT exceed the maximum working pressure level of the lowest rated system component Use only extensions and nozzles that are designed for use with this equipment Use only fluids and solvents that are compatible with the equipment
69. nem Gabelschl ssel fest anziehen Beachte Der Teil des Messger tes mit Gewinde besitzt zwei Innengewinde Das metallene Ende des Schlauches muss Aussengewinde haben Gewinde abdichtungsmittel Loctite 243 oder hnliches am usseren Ende anbringen Ein und Ausgang der Teileanschl sse sind entweder 1 2 NPT oder 1 2 BSPP je nach Messger temodell Schlauch befestigen 3 LM_OGP2Adv_BA_89_1008 Ger tebedienung Seite 6 92 5 5 D se an Ger t anschliessen 1 Auf der gegen berliegenden Seite Abdich tungsdichungsmittel an Gewinde des Auslaufs anbringen Empfohlenes Abdichtungsmittel Loctite 243 2 Auslauf an Ger t schrauben Mit Gabelschl ssel fest anziehen _ 3 Alle Zufuhsperrventile ffnen Pumpe starten um System zu beaufschlagen 4 Vor Gebrauch s mtliche Luft aus Fluidleitungen und Zufuhrventilen entfernen um pr zise Anzeige sicherstellen zu k nnen D se befestigen 6 Ger tebedienung Beachte Mit der Taste Auto kann man von manuellem Modus auf Automatik Batch Modus umschalten 6 1 Manueller Modus Im manuellen Modus wird das Messger t zum Messen m m eines freien Durchflusses betrieben QT LI LU 1 Ausl sevorrichtung ziehen um Durchfluss zu starten 2 Anzeige zeigt die gemessene Menge an 3 Sobald die gew nschte Menge gemessen wurde Ausl sevorrichtung loslassen um weiteren Durchfluss zu stoppen Manueller Modus 4 Reser y Taste einmal dr cken um Z hlerdisplay
70. nne d alimentation principale de fluide de la pompe est ferm e et que la pression d air du moteur de la pompe a t arr t e de facon appropri e 3 LM_OGP2Adv_BA_89_1008 Montage de l appareil Page 49 92 5 4 3 Ouvrir lentement la vanne d alimentation de fluide 4 Mettre l embout du tuyau dans un bac de r cup ration S assurer que le tuyau est correctement pos afin d viter tout coulement de fluide lors du rin age 5 Ouvrir lentement la soupape de mesure et permettre un coulement de fluide suffisant pour garantir la propret du syst me 6 Fermer la soupape et r p ter cette op ration pour chaque point de mesure Lorsque l installation est neuve ou lorsque le fluide pr sent dans les conduites est souill purger le syst me avant d installer l appareil de mesure Raccordement du tuyau sur l appareil Fermer la soupape de purge avant le d marrage de la proc dure 1 Fixer la pi ce sur l appareil de mesure D poser du produit d tanch it pour filetage sur embout du tuyau Produit d tanch it conseill Loctite 243 2 Introduire l embout m tallique dans la pi ce Serrer fortement a l aide d une cl amp a molette Attention La partie de l appareil avec filetage comporte deux filets de vis int rieurs taraudage L embout m tallique du tuyau doit avoir un filetage m le D poser du produit d tanch it pour filetage type Loctite 243 ou similaire sur l extr mit ext
71. nnn EE AEAEE EEEE EEEEEEEAEEEEEEEEEEEEEEEEEEEEEEEE EEEE EEEE E EEEE 3 LM_OGP2Adv_BA_89_1008 Inhaltsverzeichnis 9 Werkseinstellungen ndern u 040u0 000u0u00 Hu u nu ann nun ah una han nn hun nnmnnn 12 9 1 Brogrammierung a E a aa a a araara ara aE 12 9 2 Masseinheit andem 12 9 3 Skaliarfaktor ANA ae hei 13 9 4 O Fi al a At a et 13 9 5 nderungen pr fen unse ee ee 13 10 Skalierfaktor berechnen 0 ucscreuuuesoscuana di 13 10 1 Absoluter Skalierfaktor ann En 14 11 Fehlersuche und beseitigung nn 20 12 en TE EN 13 HerstellererkKidrUNg iii 00000 nn aan anna 90 14 DIN ISO Zertifikat uuuuuuenennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 91 gt LM_OGP2Adv_BA_89_1008 Verzichterkl rung Warnhinweise Seite 1 92 1 Verzichterkl rung Der Benutzer K ufer sollte die in dieser Bedienungsanleitung mitgeteilten Informationen gr ndlich durchlesen und verstehen den aufgelisteten Sicherheitswarnhinweisen und Instruktionen Folge leisten und diese Bedienungsanleitung bei dem Messger t aufbewahren damit sie auch in Zukunft bei Bedarf zur Verf gung steht Die in dieser Bedienungsanleitung mitgeteilten Informationen wurden sorgf ltig gepr ft sind absolut verl sslich und stimmen mit dem beschriebenen Produkt berein Nichtsdestotrotz bernimmt Badger Meter Inc keinerlei Verantwortung bei Ungenauigkeiten noch kann Badger Meter Inc haftb
72. nung LM 06 LM 1800 Nombre de Modelo LM 06 LM 1800 Model Name LM 06 LM 1800 Nom du modele LM 0G LM 1800 Baujahr ab 2008 A o de manufactura partir de 2008 Year of manufacture from 2008 Ann e de fabrication A partir de 2008 Maschinen Richtlinien Machine Directives Directivas Mecanicas Directives m caniques Referenz Reference Referencias R f rence CE Richtlinien Elektrische Betriebsmittel Electneal Device Directives Directivas El ctricas Directives lectriques CE 89 392 EEC 94 44 EEC 98 37 EC de pression 97 23 EC Druckgeraterichtliniel Pressure Equipment directive Directivas de equipo de Presi n Directive d quipment 91 368 EEC 2006 95 EC 93 68 EC 2004 108 EC 93 68 EEC Declaramos que los productos complen las Directivas anteriormente indicadas El equipo identificado arriba no debe ponerse en servicio hasta que la maquinaria a la que el mismo va a ser incorporado no haya sido declarada en conformidad con las provisiones de las directivas aplicables Unterschrift E Wannenwetsch Gesch ftsleitung Top Management amp Qualit tsmanagement Quality Manager CE Kennzeichnung C marking CE marking Marquage CE Hiermit best tigen wir die bereinstimmung unserer Ger te mit den o g Richtlinien Vor Inbetriebnahme der oben genannten Ger te muss sichergestellt sein dass die Gesamtanlage bzw Maschine in der die Ger te verwendet werden den geltenden Richtlinien und Bestimmungen entspricht We
73. ode comptage d croissant rebours l cran indique la quantit AUTO 45 mesurer souhait e Mode comptage d croissant 3 LM_OGP2Adv_BA_89_1008 Fonctions op rationnelles Page 54 92 7 Fonctions op rationnelles Ces fonctions sont valables en mode manuel et en mode Auto Batch 7 1 Suites des sommes et sommes en m moire 1 Affichage des suites de sommes et sommes en m moire e Appuyer et maintenir la touche D afin d afficher la suite des sommes e Maintenir la touche TAL appuy e e Apres 3 secondes apparait l affichage des sommes en m moire 2 L affichage Resettotal pr sente le volume total de fluide d bit depuis la derni re remise a z ro de d H L Resettotal l affichage pendant la visualisation de Resettotal Sommes en m moire de service reserroraL 3 Appuyer sur la touche RESET our la remise z ro de 4 Rel cher la touche Cortar pour retourner l affichage Attention La suite des sommes ne peut tre remise z ro que lorsque l utilisateur permute des unit s m triques aux unit s anglaises ou inversement cf r glages usines modification des unit s de mesure au point 9 2 7 2 Bouton manuel d arr t d urgence En cas d urgence ou pour interrompre une proc dure de mesure l appareil est dot d un bouton d arr t d urgence 1 Appuyer sur la touche OD de l appareil pour activer le bouton manuel d arr t d urgence La vanne est alors f
74. r 1 0123 existente x 1 05 error 1 0629 nuevo factor de escalar 6 Ingrese el nuevo valor como se describe en el Cambio del factor de escala NOTA El uso del factor de escala mostrado en la pantalla no en el gatillo 3 LM_OGP2Adv_BA_89_1008 C lculo del factor de escala p gina 83 92 Gr fica de los factores de escala aproximados para fluidos de diferentes viscosidades Factor de Escala Factor de Escala 1 00 0 99 G Fe HH CH EECH Pe tete 10 100 1000 10000 Viscosidad en centistokes a 65 3 LM_OGP2Adv_BA_89_1008 Calculo del factor de escala p gina 84 92 Ejemplos de fluidos viscosidades y factores de escala Fluido Viscosidad Factor de escala 1 Agua anticongelante 5 1 044 2 Anticongelante 18 1 007 3 L quido de frenos 42 1 004 4 ATF 80 1 002 5 10W 140 1 000 6 80W 90 450 0 999 7 140W 1800 0 993 ESPECIFICACIONES Inglesas M tricas Flujo M ximo 10 gpm 38 l min Flujo Minimo 0 25 gom 1 l min Presi n de Operaci n Maxima 1000 psi 67 bar Presi n de Operaci n Minima 5 psi 0 35 bar Temperatura de Operaci n Maxima 120 F 50 C Precision aceites 0 5 0 5 Precisi n anticongelante 1 5 1 5 Pantalla LCD 5 D gitos Cuartos pintas galones Litros Conexiones de entrada y salida Ye NPT Ve BSPP 3 LM_OGP2Adv_BA_89_1008 C lculo del factor de escala p
75. r une renouvellement suffisant de l air afin d emp cher l accumulation de vapeurs du fluide Ne pas fumer durant l alimentation en fluide S assurer que la zone d alimentation soit exempte de d chets solvants chiffons de nettoyage et flaques d essence 2 2 Risques pour le compteur L usage inappropri peut entra ner la casse de l appareil de mesure et ou un dys fonctionnement pouvant entra ner des blessures graves L usage de cet appareil est r serv un usage professionnel Lire toutes les recommandations panneaux et tiquettes avant d utiliser l appareil N utiliser l appareil que dans sa fonction premi re pour laquelle il a t con u Toute modification de l appareil est proscrire Ne pas laisser l appareil sans surveillance lors de l op ration de mesure V rifier quotidiennement l appareil Toute pi ce us e ou d t rior e doit imm diatement tre r par e ou remplac e La pression maximale de travail pr vue pour cette pi ce la puissance nominale la plus faible du syst me ne doit pas tre d pass e N utiliser que des rallonges et des coulements sp cialement con us pour cet appareil N utiliser que des fluides et des solvants compatibles avec cet appareil Lire tous les avertissements concernant les fluides et les solvants pr conis s par le fournisseur Resserrer tous les raccordements des conduites de fluide avant la mise en fonction de l appareil 3 LM_OGP2Adv_BA_89_1008 Avertis
76. re is displayed press Programming display the RESET n The unit of measure icon stops flashing 4 If L liters is selected the decimal point begins to flash You now have the option to change the decimal point to either a period or a comma e To do this press the TOTAL button D LM_OGP2Adv_BA_89_1008 Change factory settings page 34 92 9 3 9 4 9 5 5 If no scale factor changes are necessary go to save changes see point 9 4 Changing the unit of measurement from metric to English or from English to metric clears the resettable total and accumulated total Change scale factor Changing the scale factor changes the accuracy of the meter potentially causing it to overfill or under fill This has the potential to cause a mechanical breakdown Scale factor digits 1 Press the nett button to advance through the scale factor digits D d q 2 Press the tora button to change the selected ar number NOTE AN digits can be scrolled between 0 and 9 except the first It can only be scrolled from O to 1 or from 1 to 0 3 Press the RESET button to advance to the next number in scale factor 4 Repeat steps 2 and 3 for all five digits in scale factor Save changes To save changes and exit the programming mode 1 Push and hold at the same time the TOTAL and AUTO buttons 2 The display will flash 3 times and go blank 3 Press the mp button and the display will turn back on Verify changes
77. rrichtung wieder loslassen 9 Die RESET Taste dr cken wenn Vorgang abgeschlossen Die Anzeige stellt sich zur ck und das Messger t ist jetzt bereit die n chste Menge zu messen 6 3 Aufw rts Abw rtsz hlmodus 1 Wenn Sie im Auto Batch Programmiermodus sind die RESET Taste dr cken die Aufw rts Abw rtspfeile blinken dann auf dem Display 4 QT e Die TOTAL Taste dr cken um zwischen Aufw rts 2 Abwartsz hlen hin und herzuschalten x e Die RESET Taste dr cken um Aufw rts oder 45 t Abw rtsz hlfunktion zu w hlen Autw rtsz hlpfeil i Beachte Bei der Aufw rtsz hloption z hlt das QT Messger t bis zur vorprogrammierten Menge Bei der f Abw rtsz hloption z hlt das Messger t ab der pro grammierten Menge abw rts bis Null Mengenummer 3 d bedeutet immer Abw rtsz hlmodus Abw rtsz hlpfeil gt LM_OGP2Adv_BA_89_ 1008 Betriebsfunktionen Seite 9 92 2 Die AUTO Taste dr cken um Menge einzuspeichern sobald die Mengengr sse gew hlt ist Die Anzeige blinkt und das Symbol f r Batchnummer wird nicht mehr angezeigt nmr HAM TT 45 Aufw rts Z hlmodus USO 45 Abw rts Z hlmodus 7 Betriebsfunktionen Befindet sich das Messger t im Aufw rts Z hl modus zeigt das Display Nullen an Befindet sich das Messger t im Abw rts Z hl modus wird die gew nschte Mengengr sse auf dem Display angezeigt Die Funktionen
78. s csc nn 79 Cambiar la configuraci n de f brica nnmnnn 80 Ga Wel neet EE 80 9 2 Gamblar la unidad de medici n en en 80 9 3 Cambio del factor de 8s6ala ai alias 81 9 4 Guardar EE eet eeneg 8 9 5 Verificaci n de cambios kin 81 3 LM_OGP2Adv_BA_89_1008 Indice Page 68 92 10 Calculo del factor de escala siiscceiscncsciccacavasenesevescuscacedswensceiavonsveiavensseaavexavensves 82 10 1 Factor de escala absoluto eeenseeeeeeeeeeene erkeer nenene EEEn E EAEE EEEE EEEE EEEE EEEE E EEEE n EnEn 82 BEE RE ne ne 88 ben RR een 89 13 Declaraci n del Fabricante is 90 14 Certificado DIN IS ooo ren ec nassen aan scavcasactaedaassinsseasccaventee 91 Introducci n p gina 69 92 1 Terminos y Condiciones Se espera que el usuario comprador lea y entienda la informaci n proporcionada en este manual siga cualquier listado de precauci n cat logo de seguridad e instrucciones y guarde mantenga este manual con el equipo para futuras referencias La informaci n en este manual ha sido verificada cuidadosamente y se cree es completamente confiable y compatible con el producto descrito Sin embargo ninguna responsabilidad es asumida por inexactitudes asi mismo Badger Meter Inc tampoco asume cualquier responsabilidad que provenga del uso y empleo del equipo descrito Si el equipo es usado en una manera no especificada por Badger Meter Inc la protecci n proporcionada por el equipo puede s
79. sement Page 46 92 e Supprimer toutes les zones de fuite et en cas de fuite ne pas d vier l coulement accidentel du fluide ou du solvant avec la main le corps des gants ou des chiffons Ne pas diriger ce flux vers une personne ou une partie du corps e Ne pas toucher au del du p rim tre de sortie de la vanne de mesure ni introduire vos mains ou vos doigts dans la vanne de mesure e Respecter toutes les dispositions locales territoriales et nationales concernant les reglements en mati re d incendies lectriques et de s curit e Toute utilisation autre que celle d crite dans la pr sente notice d utilisation peut influencer le fonctionnement de l appareil et causer des dommages de l appareil Cet appareil de mesure est sp cialement concu pour effectuer des mesures de produits lubrifiants Ne pas Putiliser pour des fluides pour essuie glace de liquide de frein ou pour toutes autres solutions aqueuses 3 LM_OGP2Adv_BA_89_1008 Touches de l appareil de mesure Page 47 92 3 Touches de l appareil de mesure 10 1 0 1 Entr e de la quantit mesurer TOTAL Somme Affichage de la suite des sommes des fluides d bit s ainsi que de la somme mise en m moire en mode Auto Batch et manuel wm Auto __ S lection et sortie du mode manuel ou Auto Batch RESET Effacer la quantit mesur e dans le mode manuel Effacer la quantit mesur e dans le mode Auto Batch et remise a z ro de l appar
80. st possible de compenser cette diff rence Le compteur multiplie chaque impulsion par le num ro du facteur de cadrage pour corriger le degr de pr cision lorsqu il effectue la conversion dans l unite sp cifi e L affichage est ainsi toujours exact Concernant les valeurs approchantes des facteurs de cadrage pour les fluides de diff rentes viscosit s se reporter au diagramme en page 60 Attention Le facteur de cadrage initial r gl en usine de l appareil de mesure est inscrit sur la g chette Il peut avoir t verifi et modifi apr s montage Utiliser toujours le facteur de cadrage affich sur l cran et non celui inscrit sur la g chette Le changement du facteur de cadrage modifie la pr cision du compteur la quantit mesur e peut tre inf rieure ou sup rieure Ceci peut occasionner un d faut m canique Affichage du facteur de cadrage actuel u 1 Appuyer simultan ment et en continu sur les touches TOTAL et AUTO 10 1 Facteur de cadrage absolu Pour obtenir le facteur de cadrage absolu effectuer le test suivant 1 Faire passer une quantit de fluide d finie dans le compteur suivant exemple ci dessous 2 Lorsque 4 20 quarts ont t d bit s et que l cran n indique que 4 00 quarts le facteur de cadrage doit tre recalibr 3 Diviser la quantit effectivement d bit e 4 20 par la quantit indiqu e sur l cran 4 00 On obtient alors le coefficient d erreur de 1 05 4 Le fact
81. tainer follow the local code Explosion and fire Movement of fluids through the dispensing system creates static electricity Static electricity can cause volatile fumes resulting in an explosion and fire The dispensing system must be grounded Flushing procedure NOTE f the system has multiple dispense positions begin at the position farthest from the pump and move towards the pump oR D 1 Close fluid dispense valves at every position 2 Once the main fluid outlet valve at the pump is closed and the air pressure to the pump motor is properly adjusted the air valve is opened 3 Slowly open the main fluid valve 4 Place the hose end in a waste container Make sure hose is secure so no fluid leaks during flushing 5 Slowly open the dispense valve and allow enough fluid to pass through it to ensure that the system is clean 6 Close the valve and repeat for all dispense positions ACAUTION If this installation is new or if the fluid in the lines is contaminated flush the system before installing the meter s 3 LM_OGP2Adv_BA_89_1008 Meter installation 5 4 5 5 Apply meter to hose page 27 92 Close the drain valve before starting this procedure Attach the hose Apply nozzle to meter Attach the nozzle 3 1 Attach swivel to meter Apply thread sealant to the male end of the hose Recommended sealant is Loctite 243 2 Insert the metal end of the hose into the swivel Tighten complet
82. tornille los dos tornillos Remueva la tapa de la bateria para exponer las baterias 3 Reemplace las baterias viejas por nuevas El medidor requiere 4 baterias alcalinas AA NOTA EI marcado de la polaridad de las baterias se encuentra dentro del compartimento 4 Deseche las baterias Viejas de la forma apropiada acorde con las regulaciones locales NOTA El cambiar las bater as no afecta ninguno de los valores programados o los totales 3 LM_OGP2Adv BA 89 1008 Cambiar la configuraci n de f brica p gina 80 92 9 Cambiar la configuraci n de f brica Cada medidor es calibrado en la f brica para su empleo con aceite para motor v ase 9 3 Cambio del factor de escala La unidad de medici n est tambien seleccionada antes del envio Verificar la version Firmware 1 2 3 9 1 La versi n firmware y code checksum se indican pulsando las teclas TOTAL y ismal al 1 nismo tiempo Los dos ltimos d gitos al lado derecho inferior son la versi n firmware Medidores con versi n 17 o m s utilizan el procedimiento indicado en este manual para el cambio de la unidad de medida y del factor de escala Programaci n Para cambiar la configuraci n de f brica 1 Pulsar y sujetar al mismo tiempo TOTAL y AUTO 2 PrG aparece en la pantalla 3 Soltar TOTAL AUTO 4 Entonces pulsar y soltar por orden 1 Tora 10 01 Y TOTAL 5 La unidad de medida actual ahora est parpadeando para indicar l
83. tructions et avertissements de s curit contenus dans ce manuel d utilisation Ce manuel doit tre conserv proximit de l appareil de mesure afin d en permettre le recours tout moment Les informations voqu es dans ce manuel d utilisation ont fait l objet d un contr le rigoureux et sont r put es fiables et conformes au produit d crit Malgr cel la responsabilit de la soci t Badger Meter Inc ne peut tre engag e en cas d impr cision des mesures ou de d g ts g n r s par une mise en oeuvre et une utilisation inappropri e de l appareil d crit Si cet appareil de mesure fait l objet d un usage different de celui d crit par la soci t Badger Meter Inc la protection apport e cet appareil de mesure peut tre l s e et la garantie en sera caduque 2 Avertissement 2 1 Risques d explosion et d incendie Une mise la masse inad quate une a ration insuffisante des flammes ouvertes ou des tincelles peuvent g n rer une situation dangereuse pouvant d clencher une explosion un incendie voire entra ner des blessures graves Veiller une mise la masse appropri e Pour de plus amples renseignements lire le mode d emploi des pompes En cas de surcharge lectrostatique et ou en cas d lectrocution lors de l utilisation de l appareil de mesure couper imm diatement l alimentation Rechercher et supprimer la cause du probl me avant de remettre l appareil en marche Veiller tabli
84. uhait e a t pomp e l cher la gachette 9 Lorsque le cycle est termin appuyer sur la touche RESET L affichage se remet a son tat initial et le compteur est nouveau pr t pour la prochaine mesure Mode de comptage croissant d croissant 1 En mode Programmation Auto Batch appuyer sur la touche RESET et les fl ches haut bas clignotent sur l cran Appuyer sur la touche TOTAL pour un va et vient entre le mode de comptage croissant ou d croissant HILO Appuyer sur la touche RESET pour s lectionner la AUTO U 5 t fonction comptage croissant ou d croissant Fl che vers le haut uuu e mas up Attention Dans l option comptage croissant l appareil de mesure effectue le comptage jusqu a atteindre la quantit pr programm e Dans l option comptage d croissant l appareil effectue le comptage rebours partir de la quantit programm e jusqu z ro Le num ro de quantit 3 correspond toujours un comptage rebours Fl che vers le bas 3 LM_OGP2Adv_BA_89_1008 Utilisation de l appareil Page 53 92 2 Apr s s lection de l unit de mesure appuyer sur la touche AUTO our m moriser la quantit L affichage clignote et le symbole du N Batch n est plus affich mmm UU L Lorsque l appareil est en mode comptage croissant l ecran indique une suite de z ros 45 Mode comptage croissant ED LU e Lorsque l appareil est en m
85. ung kann Funkenbildung entstehen die zu einer Explosion und einem Brand f hren k nnen Leitungssystem muss geerdet sein O1 BR D Sp len Beachte Sobald das System mehrere Messpositionen besitzt an der Position die am weitesten entfernt zur Pumpe liegt beginnen und sich in Richtung auf die Pumpe vorarbeiten 1 Fluidmessventil an allen Stellen schliessen 2 Sobald das Hauptzuleitungsventil f r das Fluid an der Pumpe geschlossen ist und der Luftdruck zum Pumpenmotor ordnungsgem ss eingestellt wurde wird das Luft ventil ge ffnet 3 Hauptzuleitungsventil f r das Fluid langsam ffnen gt LM_OGP2Adv_BA_89_ 1008 Ger teeinbau Seite 5 92 4 Schlauchende in einen Auffangbeh lter legen Sicherstellen dass der Schlauch sicher untergebracht ist so dass kein Fluid beim Sp len austreten kann 5 Messventil langsam ffnen und gen gend Fluid durchfliessen lassen um sicher zustellen dass das System sauber ist 6 Ventil schliessen und diesen Vorgang bei allen Messpositionen wiederholen Wenn die Anlage neu ist oder das Fluid in den Leitungen verschmutzt sein sollte System vor Anbringen des der Messger t e s durchsp len 5 4 Ger t an Schlauch anschliessen Entleerungsventil vor Start des Verfahrens schliessen 1 Teil an Messger t befestigen Gewindeabdich tungsmittel am usseren Schlauchende anbrin gen Empfohlenes Abdichtungsmittel Loctite 243 2 Metallenes Schlauchende in Teil stecken Mit ei
86. wenn Fluid durch das Messger t fliesst gt LM_OGP2Adv_BA_89_ 1008 Service 7 5 Fehlercodes Seite 11 92 Das Messger t besitzt einen Fehlercode der angezeigt werden kann Am Messger t kann angezeigt werden wenn ein Fehler bei der Kommunikation zwischen Messger t und Tastatur aufgetreten ist SFO Skalierfaktor 0 die Skalierfaktoreinstellung f r das Messger t wird auf 0 000 gesetzt e F r die Eingabe eines g ltigen Skalierfaktors s Anleitung im Kapitel 9 Werks einstellungen ndern Alle anderen Fehlercodes dienen nur zu Herstellzwecken e Um die Anzeige auf dem Messger t zu l schen Reset dr cken 8 Service 8 1 Batterie schwach Sobald die Batterie gewechselt werden muss erscheint eine Abfolge mit Warn hinweisen auf dem Messger te Display DD l Symbol f r schwache Batterie 8 2 Batterieaustausch Erster Warnhinweis Das Symbol f r Batterie schwach wird in der linken unteren Ecke des Displays angezeigt d h die Batterien sind schwach und m ssen getauscht werden Zweiter Warnhinweis Das Batterie Symbol blinkt Die Batterie ist zu schwach und die Funktionen des Messger tes werden deaktiviert Das Fach f r die Batterien befindet sich im Geh use auf der Unterseite der Ausl se vorrichtung 1 Ger t umdrehen 2 Beide Schrauben l sen Batterieklappe entfernen um Batterien freizulegen 3 Alte Batterien ersetzen Das Messger t ben tigt 4 AA Alkali Batterien
87. wieder auf Null zu setzen 3 LM_OGP2Adv_BA_89_1008 Ger tebedienung 6 2 Auto Batch Modus Seite 7 92 Um in den Auto Batch Programmiermodus zu gelangen die AUTO Taste drticken bis eine Zahl und ein Doppelpunkt erscheinen Folgendes Bild erscheint DO o Auto Batch Programm Modus Das Messger t ist jetzt f r die Auswahl der gew nschten Messmengennummer bereit e 0 blinkt vor dem Doppelpunkt Dies ist das Symbol f r die Messmengennummer e Messmenge 0 steht f r manueller Modus s o manueller Modus e Die Messmengen 1 2 3 4 und 5 stehen f r Auto Batching und gehen bis 99 Einheiten e Verschiedene Messmengen k nnen in jeder Option gespeichert werden e Messmenge 6 steht f r Messmengen zwischen 1 und 999 Einheiten 1 Die TOTAL Taste dr cken um die Symbole f r die Messmenge durchzubl ttern und um den gew nschten Batch oder manuellen Modus zu w hlen 2 Sobald das Symbol f r die gew nschte Messmenge auf der Anzeige erscheint die Messmengengr sse durch Dr cken der 4 und vw asten eingeben DD mo up e 10er Taste dr cken um Menge um 10 Einheiten zu erh hen e 1er Taste dr cken um Menge um 1 Einheit zu er h hen e 0 1er Taste dr cken um Menge um 0 1 einer Einheit zu erh hen Auto Batch Programm Modus Option 1 LULU e ma 55 l Beachte Bei Programmierung von Option 3 e 10er Taste
88. zipiert Verwenden Sie es nicht f r Scheibenwischerfluids Bremsfl ssigkeit oder f r auf Wasser basierende L sungen gt LM_OGP2Adv_BA_89_ 1008 Tasten auf dem Messger t LCD Display Seite 3 92 3 Tasten auf dem Messger t 10 1 0 1 Eingabe der zu messenden Menge TOTAL Summe Anzeige der aufgelaufenen Summe des abgegebenen Fluids sowie der r ckstellbaren Summe w hrend des Auto Batch und manuellen Modus A AUTO Auto SAA Anwahl und Verlassen des manuellen oder Auto Batch Modus RESET L schen der im manuellen Modus gemessenen Menge L schen der im Auto Batch Modus gemessenen Menge und r cksetzen des Messger tes f r die n chste Menge R cksetzen der r ckstellbaren Summe die w hrend die Summentaste gedr ckt wird ge messen wurde Reset Abschalten oder stoppen Stoppt den Durchfluss O 4 LCD Display 1 1 zeigt die r ckstellbare Summe die aufgelaufene Summe und den Skalierfaktor an 5 4 5 L zeigt die Ma einheit an Pfeile stehen f r aufw rts abw rtsz hlen TRY RESETTOTAL 14 Mengenvorwahl BBA A 7 6 O O1 P D AUTO zeigt dass Sie sich im EPM Modus befinden Symbol f r Batterie schwach N Symbol f r Verlauf 2 4 LCD Display gt LM_OGP2Adv_BA_89_ 1008 Ger teeinbau Seite 4 92 5 Ger teeinbau 5 1 5 2 5 3 Systemdruck reduzieren 1 Schalten Sie die Stromversorgung f r die Pumpe ab bzw schliessen

Download Pdf Manuals