EE23 Notice d'utilisation - E+E Elektronik Ges.m.b.H
Contents
1. with alarm module for DC supply 60 mA for AC supply lt 110 mAgg PC or AI Si 9 Cu 3 IP65 Nema 4 Housing protection class Cable gland M16x1 5 cable 4 5 10 mm 0 18 0 39 6 P Electrical connection screw terminals max 1 5 mm AWG 16 Working temperature range of electronics 40 60 C 40 140 F Working temperature range with display 30 60 C 22 140 F Storage temperature range 40 60 C 40 140 F CE compatibility according EN61326 1 EN61326 2 3 ICES 003 ClassB C Industrial Environment FCC Part15 ClassB Alarm Module optional Output SPDT Switch up to 250V AC 8A or 28V DC 8A threshold hysteresis ettin ccur 3 RH S SA Ausschaltpunkt 7 i A ER es switching off 1 Refer to the working range of the humidity sensor m LAUNE 2 The accuracy statement includes the uncertainty of the factory calibration with an enhancement EIN i factor k 2 2 times standard deviation The accuracy was calculated in accordance with EA 4 02 and with ON US regard to GUM Guide to the Expression of Uncertainty in Measurement NO 9s 30 3 Refer to ordering guide o gt 4 Refer to accuracies of calculated values Einschaltpunkt ar 5 Operating conditions of power supply V01 Overvoltage category Il Degree of pollution class 2 N switching On 7 d so Installation altitude up to 2000m 6 562 ft ab
2. A and B versions versions are designed for wall or duct mounting C H versions with remote sensing probe Various options extend the large number of applications OPERATING ELEMENTS Display 1 CAL is indicated during the calibration procedure 2 gt is indicated when pushing button S1 refer to Opterating elements Circuit board is indicated when overstepping the threshold model EE23 with alarm module only lt is indicated when pushing button S2 refer to Opterating elements Circuit board is indicated when dropping below the threshold model EE23 with alarm module only 3 SET indication for EE23 with optional alarm output 4 C F unit for temperature C F 5 Td Tf Td dew point temperature C F Tf frost point temperature C F 6 RH unit for relative humidity RH 15 Circuit board 1 Jumper 2 Display 9 O 0 Current 5 Voltage z z ge ra LED m 4 Push Button 5 Level Potentiometer Hysteresis O Hysteresis Potentiometer 1 Jumper Selection of output range voltage output signal current output signal cores Current e ass es an I lt lt gt r oltage 2223225 Voltage olo HELF SS SSs 24 2897726 o o wo o 2 Display place for optional display 3 LED D1red lit permanently during th
3. Switch off the supply voltage Unscrew the filter cap carefully Pull out the humidity sensor element with a tweezer Put in the replacement sensor the active side see drawing has to face the inside Screw on the filter cap carefully in case of pollution replace it by a new filter cap Switch on the supply voltage Perform a humidity calibration refer to 2 point humidity calibration active side cl OO Om B O N Sensor Replacement of Soldered Sensors Switch off the supply voltage Unscrew the filter cap carefully Desolder the humidity sensor element Shorten the sensor legs of the replacement sensor with a side cutter at 4mm 0 16 from 10mm 0 39 to 6mm 0 24 see drawing Solder in the replacement sensor the active side see drawing has to face the inside Screw on the filter cap carefully in case of pollution replace it by a new filter cap Switch on the supply voltage Perform a humidity calibration refer to 2 point humidity calibration solder pins N L a active side ao ua N Self diagnosis LED D1 red LED D2 green lit permanently during the calibration routine flashes during operation lit up shortly when reset to factory calibration lit up if humidity temperature settings sensor is damaged Self help in case of errors ERROR possible cause steps against it WRONG VALUE error during or
4. La bride de montage en acier inoxydable voir Accessoires permet le montage de la sonde sur une des parois murs ext rieures de la chambre de mesure Il est galement possible d ajuster en continu la profondeur d immersion Durant le montage du couvercle la protection anti goutte voir Accessoires est utilis e pour prot ger la sonde et l l ment de d tection contre la condensation La sonde de mesure doit tre positionn e horizontalement ou verticalement dirig e vers le bas ll est recommand si possible d utiliser une plaque d gouttement pour chaque montage Montage de la sonde de mesure Mod le H 5mm Inclus accessoire pour dissimuler le montage de la sonde miniature ex mus e cadre de porte Diam tre de pergage 13mm Epaisseur mati re min 3mm Connextions lectriques Sortie et alimentation Avec sortie temp rature active Sortie alarme NC 8 NC e 11 NC z 7 MARCHE gt NC 6 no LUMINE e u Sorties OUT1 4 analogiques GND 3 ws GND 2 W I 1 Raccordement de la partie inf rieure du boitier avec des connecteurs 8 35V DC 12 30V AC Option C03 C07 Connecteur pour ali mentation et sorties analogiques vue de face Norme EU 28 D signation Assignation des connexions V 5 OQ GND 4 GND 3 OUT1 2 OUT2 1 Raccordement de la partie inf rieure du boitier avec alimentation int gr e 100 240V AC Option V01
5. Lors du d vissage du filtre veiller ne pas endommager le capteur de mesure es mesures de protection li es aux risques d lectricit statique doivent tre respect es lors de tout contact avec le capteur de mesure Connecter le capteur aux fils de raccordement uniquement Le montage le raccordement lectrique la maintenance et la mise en service ne doivent tre effectu s que par du personnel qualifi Consignes de s curit pour l utilisation du module relais avec une alimentation gt 50V Pour isoler le module d alarme optionnel du c t basse tension du transmetteur la cloison pr vue cet effet doit tre install e en partie basse Le boitier de l appareil doit tre enti rement ferm lors du fonctionnement Lindice de protection d un boitier ouvert correspond un IPOO Tout travail sur des pi ces conductrices doit tre effectu par des personnes exp riment es Consignes de s curit pour l utilisation de l alimentation int gr e option V01 e Le boitier de l appareil doit tre enti rement ferm lors du fonctionnement de l appareil e L indice de protection d un bo tier ouvert correspond un IPOO Tout travail sur des pi ces conductrices doit tre effectu par des personnes exp riment es es parties inf rieures et centrales du boitier doivent tre mises la terre lors du fonctionnement de l appareil Aspects environnementaux L quipement provenant de E E Elektron
6. N Connecteur pour sortie G Designation 5 analogique 5 GND 3 vue de face OUT1 2 OUT2 1 Euro Norm Connecteur pour boitier D signation Assignation des m tallique avec alimen connexions 1 tation 100 240V U ha AVE 3 vue de face Neutre N 3 Connecteur pour boitier D signation Assignation des polycarbonate avec ali connexions mentation 100 240V Phase L1 1 Neutre N 3 vue de face Diam tre externe du cable d alimentation 10 12mm Section max des conducteurs du cable de connexion 1 5mm AWG 16 La protection du cable d alimentation contre les surintensit s et court circuits con siste en un c ble de section 0 8mm AWG 18 fusible de 6A Les normes nationales d installation doivent tre respect es Le fond et la partie interm diaire du boitier m tallique doivent tre raccord s a la terre durant l utilisation CALIBRATION D HUMIDITE TEMPERATURE POINT DE ROS E ET DE GEL E N CALRH O O CALT Point de calibration inf rieur Les calibrations du point de ros e et du point de gel e correspondent la proc dure de calibration de l Humidit Deux m thodes de calibration sont disponibles Calibration d Humidit Temp rature 1 point calibration rapide et simple un point d Humidit Temp rature d fini point de fonctionnement Calibration d Humidit Temp rature 2 points calibration simple pour des r sultats de mesure pr cis sur toute
7. Serie EE23 FEUCHTE TEMPERATUR MESSUMFORMER HUMIDITY TEMPERATURE TRANSMITTER TRANSMETTEUR HUMIDIT TEMP RATURE MANUAL YOUR PARTNER IN SENSOR TECHNOLOGY ELEKTRONIK Ges m b H E E Elektronik Ges m b H bernimmt f r diese Publikation keinerlei Garantie und bei unsachgem fter Handhabung der beschriebenen Produkte keinerlei Haftung Diese Publikation kann technische Ungenauigkeiten oder typographische Fehler enthalten Die enthaltenen Informationen werden regelm ig ber arbeitet und unterliegen nicht dem Anderungsdienst Der Hersteller beh lt sich das Recht vor die beschriebenen Produkte jederzeit zu modifizieren bzw abzu ndern Copyright E E Elektronik Ges m b H Alle Rechte vorbehalten USA FCC Hinweis Dieses Ger t ist gepr ft worden und stimmt mit den Bedingungen f r ein Ger t der Kategorie B gem Teil 15 der FCC Richtlinien berein Diese Bedingungen sind erstellt worden um einen angemessenen Schutz gegen EMV St rungen in einem Wohnbereich sicherzustellen Dieses Ger t erzeugt verbraucht und kann Hochfrequenzenergie ausstrahlen Wenn es nicht in bereinstimmung mit der Bedienungsanleitung installiert und verwendet wird k nnen EMV St rungen zu den Funkverbindungen verursacht werden Jedoch gibt es keine Garantie dass EM St rungen nicht in einer bestimmten Installation auftreten k nnen Wenn das Ger t EMV St rungen zum Radio oder Fernsehempfang verursacht das kann festgestellt werden ind
8. 150 6 94 2 0 16 metal housing Drilling with long hole 148 5 8 s N w Model A wall mounting For mounting template for metal and polycarbonate housing see above Transmitter EE23 xAx series are designed for wall mounting working range sensor probe 40 60 C 40 140 F working range electronics 40 60 C 40 140 F D The sensor probe must point downwards Model B duct mounting For mounting template for metal and polycarbonate housing see above Positioning of bore holes top left to center line of the probe metal housing x 28 5mm 1 1 y 37 5mm 1 5 polycarbonate housing x 20 5mm 0 8 y 25 4mm 1 Transmitter EE23 xAx series are designed for duct mounting working range sensor probe 40 80 C 40 176 F working range electronics 40 60 C 40 140 F The sensor probe must point horizontal or downwards in the duct channel 17 Model C model H seperated sensor probe For mounting template for metal and polycarbonate housing see page 17 Transmitter EE23 xCx and EE23 xHx series are with seperated sensor probe working range sensor probe model C 40 120 C 40 248 F model H 40 80 C 40 176 F working range electronics 40 60 C 40 140 F i Mounting of the sensor probe model C 12mm PNE Using the stainless steel mounting flange refer to accessories it is pos 22 m
9. 3 sek langes Dr cken wird die Routine gestartet Der Kalibrationsmode wird durch das Leuchten der LED D1 und durch das Symbol CAL im LCD Display angezeigt 4 TASTER 51 up und S2 down Durch Dr cken der beiden Taster wird der Messwert in 0 1 0 1 C Schritten auf den Referenzwert abgeglichen Der Messwert kann entweder am Display abgelesen oder am Ausgang gemessen werden 5 TASTER S1 Durch mind 3 sek langes Dr cken wird der Kalibrationswert gespeichert und die Routine verlassen Das Verlassen des Kalibrationsmodes wird durch das Deaktivieren der LED D1 und dem Symbol CAL im LCD Display angezeigt TASTER S2 Durch mind 3 sek langes Dr cken wird die Routine verlassen ohne die Kalibrationswerte zu speichern Das Verlassen des Kalibrationsmodes wird durch das Deaktivieren der LED D1 und dem Symbol CAL im LCD Display angezeigt 10 gt R cksetzten der Kundenkalibration auf die Werkskalibration 2 TASTER S1 und S2 Um die RH oder T Werte r ckzusetzen muss vorher die jeweilige Jumpereinstellung gew hlt werden Werden ausserhalb des Kalibrationmodus beide Tasten gemeinsam mindestens 5 sek lange gedr ckt wird die Kundenkalibration wieder auf die Werkskalibration zur ckge setzt Optisch wird die Zur ckstellung auf die Werkskalibration durch ein kurzes Aufleuchten der LED D1 angezeigt INSTANDHALTUNG WARTUNG Sensortausch Um die angegebene Genauigkeit zu erreichen muss nach einem Sensortausch eine
10. D 2 Pkt Feuchtekalibration durchgef hrt werden Die G ltigkeit der Werkskalibration erlischt mit einem Sensortausch L tstellen Feuchtesensor nur an den Anschlussdr hten ber hren Sensortausch von gesteckten Sensoren Versorgungsspannung abschalten Filterkappe vorsichtig abschrauben Defekten Feuchtesensor mit Pinzette entfernen Ersatzsensor mit der aktiven Seite nach innen siehe Abbildung einsetzen Filterkappe vorsichtig aufschrauben bei Verschmutzung durch einen neuen Filter ersetzen Versorgungsspannung einschalten Durchf hrung einer Feuchtekalibration siehe 2 Pkt Feuchtekalibration aktive Seite NOURWN Sensortausch von gel teten Sensoren 1 Versorgungsspannung abschalten 2 Filterkappe vorsichtig abschrauben len y 3 Defekten Feuchtesensor ausl ten TA 4 Sensorbeinchen des Ersatzsensors mit einem Seitenschneider um 4mm k rzen von 10mm auf 6mm siehe Abbildung 5 Ersatzsensor mit der aktiven Seite nach innen siehe Abbildung einl ten 4mm 6 Filterkappe vorsichtig aufschrauben bei Verschmutzung durch uen aie Gale einen neuen Filter ersetzen Versorgungsspannung einschalten Durchf hrung einer Feuchtekalibration siehe 2 Punkt Feuchtekalibration N Selbstdiagnose durch LED auf der Platine 01 rot D2 gr n f leuchtet w hrend der Kalibrations Routine blinkt wahrend des Betriebs andauernd leuchtet bei defektem Feuchte leuchtet bei R cksetzun
11. Referenzwert abgeglichen Der Messwert kann entweder am Display abgelesen oder am Ausgang gemessen werden 5 TASTER S1 Durch mind 3 sek langes Dr cken wird der Kalibrationswert gespeichert und die Routine verlassen Das Verlassen des Kalibrationsmodes wird durch das Erl schen der LED D1 und dem Symbol CAL lt im LCD Display angezeigt TASTER S2 Durch mind 3 sek langes Dr cken wird die Routine verlassen ohne die Kalibrationswerte zu speichern Das Verlassen des Kalibrationsmodes wird durch das Erl schen der LED D1 und dem Symbol CAL im LCD Display angezeigt 6 Positionierung des F hlers in der Referenzfeuchte Referenztemperatur 2 oberer Kalibrationspunkt und Stabilisierung f r mindestens 30 min 7 TASTER 51 Durch mind 3 sek langes Dr cken wird die Routine f r den oberen Kalibrationspunkt gestartet Der Kalibrationsmodus wird durch das Leuchten der LED D1 und durch das Symbol CAL im LCD Display angezeigt 8 TASTER 51 up und S2 down Durch Dr cken der beiden Taster wird der Messwert in 0 1 0 1 C Schritten auf den Referenzwert abgeglichen Der Messwert kann entweder am Display abgelesen oder am Ausgang gemessen werden 9 TASTER S1 Durch mind 3 sek langes Dr cken wird der Kalibrationswert gespeichert und die Routine verlassen Das Verlassen des Kalibrationsmodus wird durch das Erl schen der LED D1 und dem Symbol CAL gt im LCD Display angezeigt TASTER S2 Durch mind 3 sek langes Dr cken wi
12. de r f rence par tape de 0 1 0 1 C La valeur mesur e peut tre soit lue partir de l affichage optionnel soit mesur e au niveau de la sortie 9 BOUTON S1 Presser ce bouton pendant au moins 3 secondes pour sauvegarder les valeurs de calibration et quitter la routine La LED D1 s teint et le symbole CAL s affiche pour indiquer que l on quitte le mode de calibration BOUTON S2 Appuyer sur ce bouton pendant au moins 3 secondes pour quitter la routine sans sauvegarder les valeurs de calibration La LED D1 s teint et le symbo le CAL s affiche pour indiquer que l on quitte le mode de calibration Calibration d Humidit Temp rature 1 point Lorsque la plage d utilisation est restreinte une Humidit Temp rature sp cifique alors une calibration 1 point ce point d Humidit Temp rature sera suffisante Conform ment la plage d utilisation un point de calibration haut ou bas doit tre s lectionn KP gt ou 50 HR KP gt ou 50 de la gamme de Temp rature Ce type de calibration r sulte en une certaine impr cision dans la plage d Humidit de Temp rature restante Proc dure de calibration d Humidit de Temp rature 1 point 1 Avant de d marrer la calibration positionner le cavalier sur CAL RH pour une cali bration Humidit sur CAL T pour une calibration Temp rature 2 Positionner le capteur dans l talon r f rence d Humidit de Temp rature po
13. der gesamten Kalibration ist auf konstante Temperatur zu achten F r eine Kalibration muss der F hler min 30 min in der Referenzfeuchte stabilisiert werden Vor einer Kalibration sollten verschmutze Filterkappen getauscht werden 2 Punkt Feuchtekalibration 2 Punkt Temperaturkalibration F r genaue Einstellungen ber den gesamten Feuchtebereich Temperaturmessbereich wird eine 2 Punkt Feuchtekalibration 2 Punkt Temperaturkalibration empfohlen Die Kalibration sollte beim unteren Kalibrationspunkt gestartet werden Abstand der 2 Kalibrationspunkte soll gt 30 r F gt 30 C aufweisen Ablauf der 2 Punkt Feuchtekalibration Temperaturkalibration Start beim unteren Kalibrationspunkt 1 Vor Beginn der Kalibration den Jumper f r eine Feuchtekalibration auf CAL RH setzen f r eine Temperaturkalibration auf CAL T setzen 2 Positionierung des F hlers in der Referenzfeuchte Referenztemperatur 1 unterer Kalibrationspunkt und Stabilisierung f r mindestens 30 min 3 TASTER S2 Durch mind 3 sek langes Dr cken wird die Routine f r den unteren Kalibrationspunkt gestartet Der Kalibrationsmode wird durch das Leuchten der LED D1 und durch das Symbol CAL im LCD Display angezeigt 9 oberer Kalibrationspunkt Si 6 D16 s si E 2 D1Q il CALRH CAL T 4 TASTER 51 up und S2 down Durch Dr cken der beiden Taster wird der Messwert in 0 1 0 1 C Schritten auf den
14. info epluse de www epluse de E E FRANCE Tel 33 4 7472 35 82 info epluse fr www epluse fr E E ITALY Tel 39 02 270 78636 info epluse it www epluse it E E KOREA Tel 82 31 732 605 0 info epluse co kr www epluse co kr E E USA Tel 1 508 530 3068 office epluse com www epluse com
15. la plage de mesure d Humidit Temp rature Avant la calibration il est recommand de stocker le transmetteur et le dispositif de calibration HUMOR 20 pendant au moins 4 heures dans une m me pi ce temp rature stable Une temp rature constante devra tre maintenue durant tout le processus Pour une calibration correcte le capteur devra tre stabilis pendant au moins 30 min la valeur d humidit de r f rence Les filtres encrass s devront tre remplac s avant toute re calibration Calibration d Humidit Temp rature 2 points Une calibration d Humidit Temp rature 2 points est recommand e pour obtenir une configuration pr cise sur toute la plage d humidit temp rature a calibration devra tre initi e au point de calibration bas Pour la calibration d humidit 2 points les points de calibration devront tre pris distants et sup rieurs 30 d HR gt 30 C Proc dure de calibration d Humidit de Temp rature 2 points D marrer avec le point de calibration inf rieur 1 Avant de d marrer la calibration positionner le cavalier sur CAL RH pour une calibration Humidit sur CAL T pour une calibration Temp rature 2 Positionner le capteur dans l talon r f rence d Humidit 1 de Temp rature 1 point de calibration bas et stabiliser pendant au moins 30 min 3 BOUTON S2 Appuyer sur ce bouton pendant au moins 3 secondes pour activer la routine de cali
16. la sonde de mesure type de montage de cette derni re Type de filtre incorret Le type de filtre doit correspondre l application Si la LED verte du circuit imprim ne clignote pas durant la mise sous tension le fusible doit tre contr l et au besoin remplac Fusible secondaire 250mA T UL248 14 Tension nominale 250V Types de remplacement S rie MSTU 250 Fabricant Schurter Nr de commande 0034 7109 S rie 374 Fabricant Littelfuse Nr de commande 374 0250 INCLUS DANS LA LIVRAISON Inclus dans tou Selon r f rence de tes les versions commande EE23 selon r f rence de commande x Manuel d utilisation EE23 x Logiciel de configuration EE PCA x D claration de conformit selon DIN EN 10204 X Cl Allen 3 0 seulement pour boitier m tallique Connecteur pour alimentation int gr e V01 Connecteur RKC 5 7 V01 C03 Presse toupe m tallique M16 sauf C03 V01 PIECES DE RECHANGE ACCESSOIRES Description Code de commande Description Code de commande Filtre HA0101xx Alimentation pour module externe V02 Protection anti rayonnement HA010504 Support de fixation pour Afficheur couvercle de boitier rails de montage HA010203 m tallique D03M Capteur de remplacement HR FE09 Afficheur couvercle de boitier Protection anti ruissellement HA010503 polycarbonate D03P Set de calibration HA0104xx Bride de montage 12mm HA010201 Etalon de calibra
17. praktische jede Anwendung eingesetzt werden Modell A f r Wandmontage Modell B f r Kanalmontage Modell C H mit abgesetztem F hler Verschiedene Optionen erweitern die Einsatzm glichkeiten BEDIENUNGSELEMENTE Display D gt OJN gt 1 CAL wird w hrend der Kalibrations Routine angezeigt 2 gt wird bei Bet tigung des Tasters S1 angezeigt siehe Kapitel Bedienungselemente Platine wird bei berschreitung des Schaltpunktes angezeigt nur bei EE23 mit Schaltmodul lt wird bei Bet tigung des Tasters S2 angezeigt siehe Kapitel Bedienungselemente Platine wird bei Unterschreitung des Schaltpunktes angezeigt nur bei EE23 mit Schaltmodul 3 SET wird bei EE23 mit optionalem Schaltausgang angezeigt 4 C F Einheit f r Temperatur in C F 5 Td Tf Td Taupunkttemperatur in C F Tf Frostpunkttemperatur in C F 6 RH Einheit f r rel Feuchte RH Platine 7 Current Voltage 1 Jumper 2 Display 3 LED D1 rot D2 gr n 4 Taster S1 S2 S1 S2 5 Level Potentiometer 1 Jumper 2 Display sls 00 a zz en o 3 LED 4 Taster 5 Level Potentiometer Hysteresis 6 Hysteresis Potentiometer Auswahl Ausgangsbereich Spannungsausgangssignale Stromausgangssignale 0000000 Current 6000000 Current 00000000 Slo 0000000 Voltage ge 4122225 Vol
18. voir chapitre Composants de fonctionnement Circuit imprim s affiche lorsque le seuil est d pass seulement avec le EE23 avec option alarme s affiche avec le EE23 avec l option alarme Unit pour la Temp rature en C F Td Temp rature de point de ros e en C F Tf Temp rature de point de gel e en C F Unit pour l Humidit Relative RH 25 Circuit imprim 2 Current Voltage 1 Cavalier 2 Afficheur 3 LED D1 rouge D2 vert 4 Bouton poussoir S1 S2 S1 S2 5 Seuil potentiom tre 6 Hyst r sis 1 Cavalier 2 Afficheur o dap ale i Iun o 3 LED 4 Boutons poussoirs 4 20mA 0 20mA 5 Seuil potentiom tre Hysteresis 6 Hyst r sis Potentiom tre S lection du signal de sortie Signal de sortie tension Signal de sortie courant en olo EEE Current 5 344 142 current Hl 44222rI Voltage Le 122235 wie doe TEPPET Sggceas CEPS E o lt 0 4o TO o Emplacement pour afficheur optionnel s allume durant toute la routine de calibration s allume bri vement durant le recouvrement aux param tres usine clignote pendant la mise en marche s allume en cas de capteur Humidit Temp rature d fectueux Bouton poussoir pour calibration Humidit Temp rature 1 point Humidit gt 5096 HR Bouton poussoir pour calibration H
19. 0 5V 1 mA lt l lt 1 mA chelle de sortie en temp rature r glable par E E 0 10V 1 mA lt lt 1 mA ou avec le kit de configuration 0 20mA Hu lt 470 Ohm 4 20mA R lt 470 Ohm Plage de mesure max ajustable de jusqu unit s EE23 A EE23 B H EE23 C Humidit rF 0 100 100 100 HR Temp rature T 40 60 80 120 C Temp rature de ros e Td 40 60 80 100 C Tf 40 0 0 0 C G n ralit s Tension d alimentation Pour sorties 0 1V 0 5V 10 5 35V DC ou 12 28V AC Consommation pour sortie tension pour alimentation DC lt 25mA Avec module alarme pour alimentation DC lt 35mA pour alimentation AC lt 35mA eff pour alimentation AC x 60mA eff Consommation pour sortie courant pour alimentation DC x 50mA Avec module alarme pour alimentation DC lt 60mA pour alimentation AC x 90mA eff pour alimentation AC lt 110mA eff Boitier Indice de protection PC ou Al Si 9 Cu 3 IP65 Presse toupe M16x1 5 c ble 4 5 10 mm Connexion lectrique Bornes visser max 1 5mm Gamme de fonctionnement en temp rature de l lectronique 40 60 C Gamme de fonctionnement en temperature avec affichage 30 60 C Gamme de temperature pour le stockage 40 60 C Compatibilit lectromagn tique EN61326 1 EN61326 2 3 ICES 003 ClassB C Environnement Industriel FCC Part15 ClassB Module d alarme option 9 M Sortie Relais inverseur coupure ma
20. 40V AC option V01 N N lua for Description Connection assignment aldi outputs ON GND 3 D O OUT1 2 front view OUT2 1 Euro Standard plug for 100 240V Description Connection assignment metal housing SE i phase ront View neutral wire N 3 plug for 100 240V O Description Connection assignment polycarbonate housing phase L1 1 front view O neutral wire N 3 External diameter of supply cable 10 12mm 0 39 0 47 Maximum wire cross section for connecting cable 1 5mm AWG 16 The protection of the supply cable against excess current and short circuit must be designated to a wire cross section of 0 8mm AWG 18 6A fuse National regulations for installation must be observed Bottom and middle part of the metal housing must be grounded during operation HUMIDITY TEMPERATURE DEW POINT FROST POINT CALIBRATION A CALT O O m S CALRH low calibration point D1 ATTY s26 The procedure of dew point and frost point calibrations are equal with the procedure of humidity calibrations The EE23 transmitter series can be calibrated in two ways 1 point humidity temperature calibration quick and simple calibration on a defined humidity temperature point working point 2 point humidity temperature calibration simple calibration for accurate measuring results over the whole humidity temperature working range To reach a temperature balance it is r
21. A B Cx 0 ITIN EE23 xHx 04 4 04 4 03 03 4 02 02 4 AC 05 0 1 f te SE air enii a e sgp Me dE 3E ai 40 30 20 10 0 01 3 as 10 20 30 40 50 60 70 80 90 100 110 120 C 02 an 04 A A E 9 I lt II L d EZE C MERO 00 000 20 D ON 9 E 02 03 o4 os Temperature dependence of electronics typ 0 002 C C Outputs 0 1V 0 5 mA lt I lt 0 5 mA 0 100 RH xx yy C 0 5V 1 mA 1 mA temperature output scale adjustable by E E or 0 10V 1 mA lt l lt 1 mA with configuration kit 0 20mA Hu lt 470 Ohm 4 20 mA R lt 470 Ohm Max adjustable output scaling from up to units EE23 A EE23 B H EE23 C Humidity RH 0 100 100 100 96 RH Temperature T 40 40 60 140 80 176 120 248 C F Dew point temperature Td 40 40 60 140 80 176 100 212 C F Frost point temperature 40 40 O 32 0 32 0 32 C F General Supply voltage for 0 1 V O 5 V outputs 10 5 35V DC or 12 28V AC for 0 10 V 0 20 mA and 4 20 mA outputs 15 0 35V DC or 15 22V AC optional 100 240V AC 5060HZ Current consumption for voltage output for DC supply x 25 mA for AC supply x 35 mA with alarm module for DC supply 35 mA for AC supply x60 mA Current consumption for current output for DC supply x 50 mA for AC supply x 90 mA
22. LACEMENT PARTS ACCESSORIES TECHNICAL DATA TABLE DES MATIERES GENERALITES Consignes de s curit DESCRIPTION DU PRODUIT COMPOSANTS DE FONCTIONNEMENT Module d affichage Circuit imprim INSTALLATION Montage boitier M tallique ou Polycarbonate Montage Mod le A Montage Mod le B Montage Mod le C Mod le H Connextions lectriques CALIBRATION HUMIDITE TEMPERATURE POINT DE GIVRE ET DE GELEE Calibration d humidit Temp rature 2 points Calibration d humidit Temp rature 1 point Recouvrement des r glages usine ENTRETIEN MAINTENANCE Remplacement du capteur Auto diagnostic vie les LED de la carte de circuits imprim s Auto diagnositc de messages d erreur Remplacement du fusible INCLUS DANS LA LIVRAISON PIECES DE RECHANGE ACCESSOIRES CARACTERISTIQUES TECHNIQUES OOO AR gt F P ALLGEMEIN Die Bedienungsanleitung ist Bestandteil des Lieferumfanges und dient der Sicherstellung einer sachgem en Handhabung und optimalen Funktion des Ger tes Aus diesem Grund muss die Bedienungsanleitung unbedingt vor Inbetriebnahme gelesen werden Dar ber hinaus ist die Bedienungsanleitung jeglichen Personen welche mit dem Transport der Aufstellung dem Betrieb der Wartung und Reparatur befasst sind in Kenntnis zu bringen Diese Bedienungsanleitung darf nicht ohne das schriftliche Einverstandnis von E E Elektronik zu Zwecken des Wettbewerbes verwendet und auch nicht an Dritte wei tergegeben werden Kopie
23. TON 51 up and S2 down Pressing the two buttons will adjust the measu ring value in steps of 0 196 0 1 degC up or down to the reference value The actual measuring value is indicated on the display or can be measured with the analogue output 5 BUTTON S1 Pressing the button for 3 seconds the calibration value is stored and the procedure is ended Exiting the calibration mode is indicated by deactivation of the LED D1 and the symbol CAL on the LC display BUTTON 52 Pressing the button for 3 seconds the calibration procedure will be ended without storing the calibration values Exiting the calibration mode is indicated by deactivation of the LED D1 and the symbol CAL on the LC display 20 Resetting the customer calibration to the factory calibration BUTTON S1 and S2 To reset the RH or T values the jumper has to be set on the 1 6 S2 6 respective location before starting the factory calibration In neutral mode pressing both buttons simultaneously for 5 seconds customer calibration settings are reset to factory calibration A short flash of the LED D1 indicates the reset MAINTENANCE Sensor Replacement the specified accuracy again The factory calibration is no longer valid after performing a sensor exchange Touch the sensor elements on the connection wires only i After changing the sensor it is necessary to perform a two point calibration to reach solder points Sensor Replacement of Pluggable Sensors
24. after recalibration of transmitter Reset to factory calibration and recalibrate according to calibration procedure filter cap polluted gt change filter cap Sensor damaged gt change humidity sensor element 21 LONG RESPONSE TIME filter cap polluted wrong filter type INSTRUMENT BREAKDOWN no supply voltage HUMIDITY VALUES TOO HIGH permanent condensation on the sensor head wrong filter type Service stations refer to back cover side Fuse replacement for option V01 If the green LED on the PCB is not flashing with the supply voltage Switched on check the fuse and replace if required Fuse secondary Nominal voltage Replacement types Series MSTU 250 Series 374 250V Manufacturer Sch SCOPE OF SUPPLY Manufacturer Littelfuse 250mA T UL248 14 urter Order No 0034 7109 Order No 374 0250 change filter cap gt adjust filter type to application gt check the connection line and voltage supply dry sensor probe and check the mounting manner of the transmitter gt adjust filter type to application Included in According to all versions ordering guide EE23 according to ordering guide x Manual EE23 x EE PCA configuration software x Inspection certificate according to DIN EN 10204 x Allen key 3 0 only for metal housing Mating plug for integrated power supply V01 Mating plug RKC 5 7 V01 C03 M16 cable glan
25. appel un technicien sp cialis radio TV Attention Toute modification apport e l appareil sans l aval pr alable d un d l gu CEM peut entrainer l interdiction d exploiter l appareil CANADA Conformit ICES 003 Cet appareil de cat gorie B correspond la norme canadienne ICES 003 INHALTSVERZEICHNIS ALLGEMEIN Sicherheitshinweise PRODUKTBESCHREIBUNG BEDIENUNGSELEMENTE Display Platine INSTALLATION Montage Metall bzw Polycarbonatgehause Montage Modell A Montage Modell B Montage Modell C Modell H Elektrische Anschl sse FEUCHTE TEMPERATUR TAUPUNKT FROSTPUNKTKALIBRATION 2 Punkt Feuchte Temperaturkalibration 1 Punkt Feuchte Temperaturkalibration R cksetzen auf Werkseinstellung INSTANDHALTUNG WARTUNG Sensortausch Selbstdiagnose durch LED auf der Platine Selbsthilfe bei St rungen Sicherungstausch LIEFERUMFANG ERSATZTEILE ZUBEH R TECHNISCHE DATEN TABLE OF CONTENTS GENERAL Safety instructions PRODUCT DESCRIPTION OPERATING ELEMENTS Display Circuit board INSTALLATION Mounting of metal and polycarbonate housing Mounting Model A Mounting Model B Mounting Model C Model H Electrical Connections HUMIDITY TEMPERATURE DEW POINT FROST POINT CALIBRATION 2 point humidity temperature calibration 1 point humidity temperature calibration Reset to factory calibration MAINTENANCE Sensor Replacement Self diagnosis Self help in case of errors Fuse replacement SCOPE OF SUPPLY REP
26. asically and may only be executed by trained personnel The protection class of the opened housing is IP00 Components with dangerous voltages can be touched directly Safety instructions for use of the integrated power supply option V01 During operation of the instrument the modular housing must be completely closed The protection class of an opened housing corresponds to IPOO In general work on live components should be avoided and when absolutely necessary should be performed by qualified personnel only The bottom part and the middle part of the housing must be grounded during operation Environmental aspects Equipment from E E Elektronik is developed with due consideration to all resultant environmental issues When you dispose the equipment you should avoid environmental pollution For disposal of the transmitter the individual components must be sorted with care The housing consists of recyclable polycarbonate or metal aluminium Al Si 9 Cu 3 The electronics must be collected as electronic scrap and disposed of according to the regulations in force 14 PRODUCT DESRCRIPTION The EE23 transmitter series stands for multifunctionality highest accuracy easy mounting and service The construction of the transmitter enables easy installation and the possibility for fast exchange of the sensor unit for service purposes The EE23 can be employed in all common applications by choosing the appropriate housing combination
27. bration du point inf rieur La LED D1 de la carte de circuits imprim s s illumine pour indiquer le mode de calibration et le symbole CAL lt s affiche 29 Point de calibration sup rieur S1 6 D1 D 52 6i CALRH O O CALT 4 BOUTON S1 haut et S2 bas Appuyer sur ces boutons pour faire correspondre la valeur mesur e avec la valeur de r f rence par tapes de 0 1 0 1 C La valeur mesur e peut tre soit lue partir de l affichage optionnel soit mesur e au niveau de la sortie 5 BOUTON S1 Appuyer sur ce bouton pendant au moins 3 secondes pour sauvegar der la valeur de calibration et quitter la routine La LED D1 s teint et le symbole CAL s affiche pour indiquer que l on sort du mode de calibration BOUTON S2 Appuyer sur ce bouton pendant au moins 3 secondes pour quitter la routine sans sauvegarder les valeurs de calibration La LED D1 s teint et le symbole CAL s affiche pour indiquer que l on sort du mode de calibration 6 Positionner le capteur dans l talon r f rence d Humidit de Temp rature 2 point de calibration haut et stabiliser pendant au moins 30 min 7 BOUTON S1 Presser ce bouton pendant au moins 3 secondes pour initier la routi ne relative au point de calibration haut La LED D1 s allume et le symbole CAL gt s affiche pour indiquer le mode de calibration 8 BOUTON S1 haut et S2 bas Presser ces boutons pour faire correspondre la valeur mesur e avec la valeur
28. d metal except C03 V01 REPLACEMENT PARTS ACCESSORIES Name order code Name order code bracket for installation onto mounting rails HA010203 drip water protection HA010503 external power supply unit V02 radiation shield HA010504 replacement sensor FEO09 filter caps HAO0101xx mounting flange 12mm HA010201 display cover in metal DO3M mounting flange 5mm for model H only HA010208 display cover in PC DOSP calibration set HA0104xx 1 calibration EE90 3H 22 TECHNICAL DATA Measured quantities Relative humidity Humidity sensor EE23 xA B Cx EE23 xHx HC1000 200 HC105 0 100 RH Accuracy including hysteresis non linearity and repeatability traceable to intern standards administrated by NIST PTB BEV EE23 xA B Cx EE23 xHx 15 40 C 5 104 F 9096 RH 1 3 0 3 mv RH 1 8 0 3 mv RH 15 40 C 5 104 F gt 90 RH 2 3 RH 2 8 RH 25 70 C 13 158 F 1 4 1 mv RH 1 9 1 mv RH A0 120 C 40 248 F 1 5 1 5 mv RH i typ 0 015 RH C R nse time with metal grid filter at 20 C t 15 sec Temperature Temperature sensor element EE23 xA B Cx Pt1000 class A DIN EN 60751 EE23 xHx Pt1000 class B DIN EN 60751 Working range sensing head EE23 xAx 40 60 C 40 140 F EE23 xBx 40 80 C 40 176 F EE23 xCx 40 120 C 40 248 F EE23 xHx 40 80 C _ 40 176 F Accuracy c 05 4 EE23 x
29. e calibration routine lit up shortly when reset to factory calibration settings D2 green flashes during operation lit up if humidity temperature sensor is damaged 4 Push Button S1 for 1 point humidity temperature calibration humidity gt 5096 RH for 2 point humidity temperature calibration high calibration point to store the calibration settings S2 for 1 point humidity temperature calibration humidity 50 RH for 2 point humidity temperature calibration low calibration point to exit the calibration procedure without storing the calibration values S1 S2 to reset to factory calibration settings 5 Level Potentiometer set the threshold model EE23 with alarm module only 6 Hysteresis Potentiometer set the hysteresis model EE23 with alarm module only 16 all dimensions in mm INSTALLATION polycarbonate housing es LT Mounting of metal and polycarbonate housing 1 Drill the mounting holes according to the mounting template For the polycarbonate housing a special mounting set for installation onto mounting rails is available refer to Accessories 2 The bottom part of the housing is mounted with 4 screws screw diameter lt 4 2mm 0 2 not included in the scope of supply 3 Connection of the transmitter refer to electrical connection 4 Mounting of the middle part and cover with 4 screws included in the scope of supply Drilling with round hole
30. ecommended to keep the transmitter and the reference chamber e g HUMOR 20 for minimum 4 hours in the same room During calibration procedure it is important to keep the temperature constant For calibration the humidity sensor probe must be stabilised at least 30 minutes in the reference chamber Replace a used dirty filter cap before calibration 2 point humidity calibration 2 point temperature calibration For accurate adjustment over the whole working range a two point calibration is recommended Start calibration at the low calibration point The difference between the two calibration points should be gt 30 RH gt 30 degC 86 F 2 point humidity calibration procedure temperature calibration procedure Start at low calibration point 1 At the beginning of a humidity calibration set the jumper to CALRH for a temperature calibration set the jumper to CAL T 2 Insert the sensor probe into the reference humidity reference temperature 1 low calibration point and stabilise for at least 30 minutes 3 BUTTON S2 Pressing the button for 3 seconds starts the procedure for the low calibration point The calibration mode is indicated by the lit LED D1 and by the symbol CAL on the LC display 19 high calibration point sif Di S si sb s2 amp 81 T F EE lt 0 4 BUTTON S1 up and S2 down Pressing the two buttons will adjust the measu ring value in steps of 0 1 0 1 de
31. em man das Ger t ein und ausschaltet wird dem Benutzer empfohlen die EMV St rungen durch folgende Ma nahmen zu beheben Stellen Sie die Antenne neu ein oder verlagern Sie die empfangende Antenne Erh hen Sie den Abstand zwischen dem Ger t und dem Empf nger Schlie en Sie das Ger t an einem anderen Stromkreis als den Empf nger an Fragen Sie den H ndler oder einen erfahrenen Radio TV Techniker Vorsicht nderungen am Ger t die nicht ausdr cklich durch einen EMV Beauftragten genehmigt sind k nnen dazu f hren dass der Betreiber das Ger t nicht mehr gebrauchen darf KANADA ICES 003 Bescheid Dieses Ger t der Kategorie B entspricht der kanadischen Norm ICES 003 E E Elektronik Ges m b H doesn t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the described products The document may contain technical inaccuracies and typographical errors The content will be revised on a regular basis These changes will be implemented in later versions The described products can be improved and changed at any time without prior notice Copyright E E Elektronik Ges m b H All rights reserved USA FCC notice This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipm
32. ement de l lectronique 40 60 C D Le transmetteur doit tre mont avec la sonde orient e vers le bas Montage du mod le B Montage sur gaine Pour le percage et les dimensions des boitiers m tallique ou polycarbo nate voir ci dessus Positionnement du percage pour le passage de sonde position de d part en haut gauche boitier m tallique x 28 5mm y 37 5mm boitier polycarbonate x 20 5mm y 25 4mm Les transmetteurs S rie EE23 xBx sont congus pour un montage sur gaine Gamme de fonctionnement de la sonde 40 80 C D Gamme de fonctionnement de l lectronique 40 60 C Le transmetteur doit tre mont avec la sonde dispos e horizontalement ou orient e vers le bas sur la gaine 27 _ Bride de B 13 o5 2 acier inoxydable protection P anti goutte 2 v Vas lt Eviter les variations brutales de gt coude de drainage lt G 3 temp rature le long de la sonde de m sure condensation Montage Montage horizontal vertical Montage du mod le C mod le H Sonde de mesure d port e Pour le per age et les dimensions des bo tiers m tallique ou polycarbo nate voir page 7 Les transmetteurs S rie EE23 xCx et EE23 xHx sont des transmetteurs avec sondes de mesure d port es Gamme de fonctionnement de la sonde Mod le C 40 120 C Mod le H 40 80 C Gamme de fonctionnement de l lectronique 40 60 C Montage de la sonde de mesure Mod le C 12mm
33. ent generates uses and can radiate radio frequency energy and if not installed and used in accordance with the installation manual may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this device CANADIAN ICES 003 notification This Device B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada E E Elektronik GmbH ne porte aucune garantie et se d gage de toute responsabilit quant a cette publication ou a un traitement inappropri des produits d crits Le document peut contenir des impr cisions techniques ainsi que des erreurs typographiques Les informations contenues seront r guli rement r vis
34. es Ces modifications seront apport es dans des versions ult rieures Les produits d crits peuvent tre am lior s et modifi s tout moment Les caract ristiques techniques sont sujettes modification Copyright E E Elektronik Ges m b H Tous droits r serv s USA Consigne FCC Cet appareil a t contr l et r pond aux exigences relatives aux appareils de cat gorie B conform ment la partie 15 des directives FCC Ces exigences ont t tablies afin d assurer une protection raisonnable CEM contre les perturbations lectromagn tiques dans les habitations Cet appareil g n re consomme et peut diffuser de l nergie haute fr quence Les liaisons radio peuvent subir des perturbations lectromagn tiques d s lors qu il n est pas install et exploit conform ment au manuel d utilisation N anmoins des perturbations lectromagn tiques peuvent appa raitre dans une installation donn e Si l appareil cause des perturbations lectromagn tiques la r ception radio ou TV ceci peut tre v rifi en mettant l appareil en marche puis l arr t il est conseill l utilisateur d liminer les perturbations lectromagn tiques en prenant les mesures suivantes Revoir le r glage de l antenne de r ception ou d placer l antenne Augmenter la distance s parant l appareil du r cepteur Brancher l appareil un circuit lectrique distinct de celui du r cepteur Contacter le revendeur ou faire
35. g auf Werkskalibratior Temperatur Sensor kurz auf Selbsthilfe bei St rungen Fehler m gliche Ursache gt Ma nahme Falsche Werte Fehler bei Rekalibration des Messumformers R cksetzen auf Werkskalibration und wiederholen der Kalibrationsroutine Filter verschmutzt 5 Filtertausch Sensor defekt gt Sensortausch 11 Lange Ansprechzeit Filter verschmutzt falscher Filtertyp Ger teausfall keine Versorgung zu hohe Feuchtewerte Betauung im F hlerkopf falsche Filtertype Servicestellen siehe hintere Umschlagseite Nennspannung Ersatztypen Serie MSTU 250 LIEFERUMFANG Hersteller Littelfuse 250V Hersteller Schurter Filtertausch Filtertyp ist an die Applikation anzupassen gt Zuleitung und Versorgungsspannung berpr fen F hlerkopf trocknen und Montage des Messf hlers berpr fen Filtertype ist an die Applikation anzupassen Sicherungstausch f r Option V01 Sicherung sekund r 250mA T UL248 14 BestNr 374 0250 BestNr 0034 7109 Blinkt die gr ne LED auf der Platine bei angelegter Versorgungsspannung nicht ist die Sicherung zu berpr fen und bei Bedarf auszutauschen Serie 374 bei allen Varianten im Lieferumfang enthalten It Bestellcode im Lieferumfang vorhanden DIN EN10204 3 1 EE23 It Bestellcode x Bedienungsanleitung EE23 x EE PCA x Konfigurationssoftware Abnahmepr fzeugnis gem x I
36. gC up or down to the reference value The actual measuring value is indicated on the display or can be measured with the analogue output 5 BUTTON S1 Pressing the button for 3 seconds the calibration value is stored and the procedure is ended Exiting the calibration mode is indicated by deactivation of the LED D1 and the symbol CAL lt on the LC display BUTTON S2 Pressing the button for 3 seconds the calibration procedure will be ended without storing the calibration values Exiting the calibration mode is indicated by deactivation of the LED D1 and the symbol CAL lt on the LC display 6 Insert the sensor probe into reference humidity reference temperature 2 high calibration point and stabilise for minimum 30 min 7 BUTTON S1 Pressing the button for 3 seconds starts the procedure for the high calibration point The calibration mode is indicated by the lit LED D1 and by the symbol CAL gt on the LC display 8 BUTTON S1 up and S2 down Pressing the two buttons will adjust the measu ring value in steps of 0 196 0 1 degC up or down to the reference value The actual measuring value is indicated on the display or can be measured with the analogue output 9 BUTTON 51 Pressing the button for 3 seconds the calibration value is stored and the procedure is ended Exiting the calibration mode is indicated by deactivation of the LED D1 and the symbol CAL gt on the LC display BUTTON 52 Pressing the button for 3 second
37. ik GmbH est d velopp en totale consid ration de toutes les contraintes environnementales r sultantes la mise au rebut de l quipement devra ainsi respecter ces contraintes environnementales Il est important de trier chaque composant individuel avec pr caution lors de la mise au rebut du transmetteur Le boitier est constitu de m tal Al Si 9 Cu 3 recyclable Les composants lectroniques doivent tre collect s comme fragments lectroniques et mis au rebut conform ment la r glementation en vigueur 24 DESCRIPTION DU PRODUIT Les s ries EE23 sont des transmetteurs multifonctions d une grande pr cision faciles a installer et a entretenir grace au nouveau concept de boitier compos de 3 modules Le EE23 peut tre utilis dans la plupart des applications en choisissant la combinaison de boitier appropri e Mod le A pour un montage mural Mod le B pour un montage en gaine e Mod le C H pour un montage avec sonde d port e Les diff rentes options permettent diverses possibilit s de montage COMPOSANTS DE FONCTIONNEMENT Module d affichage O gt 1 CAL 3 SET 4 C F 5 Td Tf 6 96RH s affiche durant la routine de calibration s affiche en activant le bouton S1 voir chapitre Composants de fonctionnement Circuit imprim s affiche lorsque le seuil est d pass seulement avec le EE23 avec option alarme s affiche en activant le bouton S2
38. insatzbereich Messfuhler EE23 xAx 40 60 C EE23 xBx 40 80 C EE23 xCx _ 40 120 C EE23 xHx _ 40 80 C Genauigkeit AC 05 AC 05 SE sm lt MEM K T bh nqiqkei Elel i typ 0 002 C C Ausgange 0 1V 0 5 mA lt I lt 0 5 mA 0 100 rF xx yy C 0 5V 1 mA lt lt 1 mA Temperaturabbildungsbereich wird von E E eingestellt 0 10V 1 mA lt l lt 1mA 0 20 mA Hu lt 470 Ohm 4 20mA H lt 470 Ohm Max einstellbarer Ausgangsbereich von bis Einheit EE23 A EE23 B H EE23 C Feuchte rF 0 100 100 100 rF Temperatur T 40 60 80 120 C Taupunkttemperatur Td 40 60 80 100 C Frostpunkttemperatur Tf 40 0 0 0 C Allgemeines Versorgungsspannung fur 0 1 V 0 5 V Ausgangssignal f r 0 10 V 0 20 mA und 4 20 mA 10 5 35V DC oder 12 28V AC 15 0 35V DC oder 15 28V AC optional 100 240V AC 50 60Hz Stromverbrauch bei Ausgabe eines Spannungssignals bei DC Versorgung lt 25 mA mit Alarmmodul bei DC lt 35 mA bei AC Versorgung lt 35 mAg bei AC lt 60 mA Stromverbrauch bei Ausgabe eines Stromsignals bei DC Versorgung lt 50 mA mit Alarmmodul bei DC lt 60 mA bei AC Versorgung lt 90 mA bei AC lt 110 mA Geh use Schutzklasse 5 PC bzw AI Si 9 Cu 3 IP65 Elektrische Anschl sse Schraubklemmen f r max 1 5 mm Betriebstemperaturbereich der Elektronik 40 60 C Betriebstemperaturbereich mit D
39. int de calibration et stabiliser pendant 30 minutes 3 BOUTON S1 point de calibration gt 50 HR gt 50 de la gamme de Temp rature Presser ce bouton pendant au moins 3 secondes pour initier la routine La LED D1 s allume et le symbole CAL s affiche pour indiquer le mode de calibration ou BOUTON S2 point de calibration 50 HR 50 de la gamme de Temp rature Presser ce bouton pendant au moins 3 secondes pour initier la routine La LED D1 s allume et le symbole CAL s affiche pour indiquer le mode de calibration 4 BOUTON S1 haut et S2 bas Appuyer sur ces boutons pour faire correspondre la valeur mesur e avec la valeur de r f rence par tapes de 0 1 0 1 C La valeur mesur e peut tre soit lue partir de l affichage optionnel soit mesur e au niveau de la sortie 5 BOUTON S1 Appuyer sur ce bouton pendant au moins 3 secondes pour sauvegar der la valeur de calibration et quitter la routine La LED D1 s teint et le symbole CAL s affiche pour indiquer que l on sort du mode de calibration BOUTON S2 Appuyer sur ce bouton pendant au moins 3 secondes pour quitter la routine sans sauvegarder les valeurs de calibration La LED D1 s teint et le symbole CAL s affiche pour indiquer que l on sort du mode de calibration 30 brasure Cot actif brasure Cot actif il R initialisation de la calibration personnalis e par la calibration usine BOUTON S1 et S2 Les cava
40. isplays 30 60 C Lagertemperaturbereich 40 60 C erf llt CE Richtlinie gem EN61326 1 EN61326 2 3 C Industrieumgebung Alarm Modul optional Ausgang Wechselkontakt f r ER 1 3 max 250VAC 8A ER di oder 28VDC 8A Z CH 7 Schaltpunkt Hysterese 1 HYSTERESIS 10 95 rF 3 15 rF En r Einstellgenauigkeit 3 rF wo E 20 1 Bezogen auf den Arbeitsbereich des Feuchtesensors 3 Siehe Bestellcode 4 Genauigkeit der Rechenfunktionen beachten 6 Stecker siehe Zubeh r 2 Die Toleranzangaben beinhalten die Unsicherheit der Werkskalibration mit einem Erweiterungsfaktor k 2 2 fache Standardabweichung Die Berechnung der Toleranz erfolgte nach EA 4 02 unter Ber cksichtigung des GUM Guide to the Expression of Uncertainty in Measurement NC AUS D T OFF 5 Einsatzbereich Netzteil V01 berspannungskategorie Il Verschmutzungsgrad Klasse 2 Aufstellh he bis 2000m 13 Einschaltpunkt __ Switching On 76 so so gt Schaltpunkt switching point 62 70 GENERAL The manual is a part of the scope of supply and serves to ensure proper handling and optimum functioning of the instrument For this reason the manual must be read before start up In addition the manual is for all personnel who require knowledge concerning transport setup operation maintenance and repair The manual must not be used for the purpose of competition without a written consent fr
41. liers doivent d abord tre s lectionn s pour r inialiser les valeurs HR ou T Appuyer simultan ment sur les deux boutons pendant au moins 5 secondes pour r in itialiser la calibration personnalis e avec la calibration usine La LED D1 s illumine bri vement pour indiquer l initialisation avec la calibration usine ENTRETIEN MAINTENANCE Remplacement du capteur Pour atteindre la pr cision indiqu e une calibration 2 points doit tre r alis e apr s le remplacement du capteur La calibration usine r alis e apr s le remplacement du capteur est valid e par la LED qui s allume Le capteur d humidit ne doit tre touch qu au niveau des fils de raccordement Echange des capteurs embrochables Mettre l alimentation lectrique hors tension D visser pr cautionneusement le capuchon filtre Retirer le capteur d humidit endommag avec des pincettes Ins rer le capteur de rechange avec le c t actif orient vers l int rieur voir le dia gramme Visser pr cautionneusement le capuchon filtre le remplacer si encrass Etablir la connexion Effectuer une calibration d Humidit voir calibration d Humidit 2 points N NO Echange des capteurs soud s 1 Mettre l alimentation lectrique hors tension 2 D visser pr cautionneusement le capuchon filtre 3 Dessouder le capteur d humidit d fectueux 4 Raccourcir les pattes du capteur de remplacement de 4mm soi
42. mit einem abgesetzten Messf hler Einsatzbereich F hler Modell C 40 120 C Modell H 40 80 C Einsatzbereich Elektronik 40 60 C Montage des Messf hlers Modell C 12mm Der Montageflansch aus Edelstahl siehe Zubeh r erm glicht eine einfa che Montage an der Messraum Aussenwand und eine stufenlose Verstellung der Eintauchtiefe Bei der Deckenmontage wird ein Tropfwasserschutz siehe Zubeh r zum Schutz des F hlers und der Sensorelemente empfohlen Der Messf hler muss horizontal oder vertikal nach unten montiert sein Wenn m glich sollte bei jeder Montage ein Abtropfbogen gelegt werden Montage des Messf hlers Modell H 5mm Inkl Montagevorrichtung zur versteckten Montage des Miniaturf hlers z B in Museen T rzargen usw Bohrungsdurchmesser 13mm Materialst rke min 3mm Schaltausgang mit aktiven Temperaturausgang 8989 Speisung IR V ne RING z 4 c N 12 nicht erreicht T wo mam le 13 analoge Ausgangs signale Anschlussbelegung Gehauseunterteil mit Steckanschl ssen 8 35V DC 12 30V AC Option C03 C07 Stecker f r Versorgung und Analogausgange Ansicht von vorne Bezeichnung Buchsenbelegung O V 5 GND 4 Ome GND 3 OUT1 2 Euro Norm OUT2 4 Anschlussbelegung Gehauseunterteil mit integriertem Versorgungsnetzteil 100 240V AC Option V01 N Stecker f r Bezeichnung Buchsenbelegung Analogausgange GND 3 Ansich
43. n f r den Eigenbedarf sind erlaubt S mtliche in dieser Anleitung enthaltene Angaben technische Daten und Darstellungen basieren auf zum Zeitpunkt der Erstellung verf gbaren Informationen Symbolerkl rung Dieses Zeichen zeigt Sicherheitshinweise an Sicherheitshinweise sind unbedingt zu befolgen Bei Nichtbeachtung k nnen Verletzungen von Personen oder Sachsch den entstehen E E Elektronik bernimmt daf r keine Haftung Dieses Zeichen zeigt Hinweise an Um die optimale Funktion des Ger tes zu gew hrleisten sind Hinweise zu befolgen Allgemeine Sicherheitshinweise bemm kige mechanische und unsachgem e Beanspruchungen sind unbedingt zu vermeiden e Vorsicht beim Abschrauben der Filterkappe da das Sensorelement besch digt werden kann Beim Sensorelement handelt es sich um ein ESD gef hrdetes Bauteil d h beim Ber hren des Sensorelementes sind ESD Schutzma nahmen einzuhalten Sensoren nur an den Anschlussdr hten ber hren Montage elektrischer Anschluss Wartung und Inbetriebnahme d rfen nur von dazu ausgebildetem Fachpersonal durchgef hrt werden Sicherheitshinweise f r Verwendung des Schaltmoduls mit Spannungen gt 50V Zur Trennung des Schaltmoduls von den Anschlussklemmen muss die daf r vorge sehene Trennwand im Unterteil montiert sein W hrend des Betriebes muss das Ger t geschlossen sein Die Schutzart des ge ffneten Geh uses ist IP00 Bauteile mit gef hrlichen Spannungen k
44. nnen direkt ber hrt werden Arbeiten an spannungsf hrenden Teilen sind grund s tzlich zu unterlassen und d rfen nur von geschultem Personal durchgef hrt wer den Sicherheitshinweise f r Verwendung des integrierten Netzteils Option V01 Das Geh use muss w hrend des Betriebs vollst ndig geschlossen sein e Die Schutzklasse eines ge ffneten Geh uses entspricht IPOO Arbeiten an spannungsf hrenden Teilen sind grunds tzlich zu unterlassen und d rfen nur von ausgebildeten Fachleuten durchgef hrt werden e Das Geh useunterteil und das Geh usemittelteil m ssen im Betriebszustand geerdet sein Umweltaspekte Die Produkte von E E Elektronik werden unter Ber cksichtigung aller wichtigen Umweltaspekte entwickelt Aus diesem Grund sollte auch bei der Entsorgung auf Vermeidung von Umweltverschmutzung geachtet werden Bei Entsorgung des Messumformers muss auf die sortenreine Trennung der einzelnen Komponeten geachtet werden Das Geh use besteht aus recyclingf higem Polycarbonat bzw Metall Aluminium AI Si 9 Cu 3 Die Elektronik muss im Elektronikschrott gesammelt und fachgerecht entsorgt werden 4 PRODUKTBESCHREIBUNG Die EE23 Messumformer Serie steht f r Multifunktionalitat h chste Genauigkeit einfache Montage und Wartung Das 3 teilige Geh use erm glicht eine einfache Installation und im Servicefall einen raschen Wechsel der Messeinheit Geh usemittelteil Durch Wahl der passenden Bauformen kann der EE23 f r
45. nnensechskantschl ssel 3 0 nur bei Metallgeh use Gegenstecker f r V01 integriertes Netzteil Gegenstecker RKC 5 7 V01 C03 M16 Kabelverschraubung Metall au er C03 V01 ERSATZTEILE ZUBEH R Bezeichnung Filterkappen Strahlungsschutz Display Deckel in Metall Display Deckel in PC Montageflansch 12mm Montageflansch 5mm nur f r Modell H Bestellcode HAO0101xx HA010504 D03M DO3P HA010201 HA010208 12 Bezeichnung Versorgungsnetzteil Aufsatz f r Hutschienenmontage F Austauschsensoren Tropfwasserschutz Kalibrierset 1 Kalibration Bestellcode V02 HA010203 FE09 HA010503 HA0104xx EE90 3H TECHNISCHE DATEN Messwerte Relative Feuchte Feuchtesensor EE23 xA B Cx HC1000 200 EE23 xHx HC105 D 0 100 rF Genauigkeit inkl Hysterese Nichtlinearitat und Wiederholgenauigkeit EE23 xA B Cx EE23 xHx 15 40 C lt 90 rF 1 3 0 3 MW rF 1 8 0 3 MW rF 15 400C gt 390 rF 2 396 rF 2 896 rF 25 70 C 1 4 1 MW rF 1 9 1 MW rF 40 120 C 1 5 1 5 MW rF Temperaturabh ngigkeit der Elektronik Ansprechzeit mit Metallgitterfilter bei 20 C too typ 0 015 rF C lt 15s Temperatur Temperatur Sensor EE23 xA B Cx Pt1000 Toleranzklasse A DIN EN 60751 EE23 xHx Pt1000 Toleranzklasse B DIN EN 60751 E
46. om E E Elektronik and must also not be forwarded to third parties Copies for personal use are permitted All information technical data and illustrations contained in these instructions are based on information available at the time of publication Symbol assertion This symbol indicates a safety instruction These safety instructions should always be followed carefully By not following these instructions injuries of persons or material damage could happen Therefore E E Elektronik does not accept liability This symbol indicates a note These notes should be followed to achieve optimum functioning of the equipment General safety instructions Extreme mechanical stress and improper use must be avoided Be careful when removing the filter cap to avoid damage of the sensor element The sensor is an Electro Static Discharge sensitive component ESD When touching the sensor element ESD protective measures should be followed Hold the sensor on the connection wires only Installation electrical connection maintenance and start up procedures should be executed by qualified technical personel only Safety instructions for using the alarm output module with voltages gt 50V For the separation of the alarm output module from the connecting terminals the the refor designated partition must be mounted in the bottom During operation the housing of transmitter must be closed Work on live parts is to be omitted b
47. ounting flange sible to mount the probe on the outer wall of the measuring chamber em qrip water The depth of immersion is adjustable protection HE For roof installations use the drip water protection refer to accessories temperature gradient along BOW for draining 188 to protect the sensor head and elements against condensed water the probe should be avoided UR horizontal mounting roof mounting The transmitter probe must point horizontal or downwards The cable should hang loosely bend for draining water of condensation Mounting of the sensing probe model H 5mm Incl mounting fixture for concealed mounting or in tight spaces e g in museums door frame etc bore diameter 13mm 0 5 material thickness min 3mm 0 1 Electrical connections output and supply alarm output with active temperature output NC 8 vw BNI z OFF d NC z i switching point N 12 not exceeded NC 6 tL N N 13 V OUT2 5 mA V analogue EA OUT1 4 outputs GND 3 Power supply I END V Connection configuration of bottom part of the housing with plug connections 8 35V DC 12 30V AC option C03 C07 Description Connection assignment plug for supply and 4 Gi V 5 analogue output 6 GND front view OU Gi GND OUT1 Euro Standard OUT2 N y _ N O 18 Connection configuration of bottom part of the housing with integrated power supply 100 2
48. ove sea level AUS Z LLL LEVEL 6 Connection plugs refer to ordering guide OFF P D i gt 62 zo Schaltpunkt switching point 23 gt GENERALITES Le manuel d utilisation est un l ment de la livraison standard et assure une manipulation appropri e et un fonctionnement optimal de l appareil Pour cette raison le manuel d utilisation doit tre consult avant toute mise en service De plus ce manuel d utilisation doit tre transmis chaque personne intervenant pour le transport la mise en service l utilisation la maintenance et la r paration Ce manuel d utilisation ne peut tre utilis des fins concurrencielles ou transmis un tiers sans accord crit pr alable de E E Elektronik Toute copie pour les besoins de l utilisateur est autoris e Les informations contenues dans ce manuel les donn es et sch mas techniques sont bas s sur les informations disponibles un temps donn Explication des symboles Ce symbole indique une consigne de s curit Les consignes de s curit doivent absolument tre respect es Leur non respect peut provoquer des blessures aux utilisateurs ou l endommagement des mat riels E E Elektronik n assume alors aucune responsabilit Ce symbole indique une remarque Ces consignes doivent tre respect es afin d obtenir un fonctionnement optimal de l appareil Consignes de s curit Toute sollicitation m canique extr me et incorrecte doit tre vit e
49. rd die Routine verlassen ohne die Kalibrationswerte zu speichern Das Verlassen des Kalibrationsmodes wird durch das Erl schen der LED D1 und dem Symbol CAL gt im LCD Display angezeigt 1 Punkt Feuchtekalibration 1 Punkt Temperaturkalibration Ist der Arbeitsbereich auf einen bestimmten Feuchte Temperaturbereich beschrankt so ist eine 1 Punkt Feuchtekalibration 1 Punkt Temperaturkalibration f r diesen Feuchtepunkt ausreichend Es sollte entsprechend dem Arbeitsbereich entweder der obere oder untere Kalibrationspunkt gew hlt werden KP gt oder lt 50 r F KP gt oder lt 50 vom Temperaturmessbereich Durch diese Art der Kalibration ergibt sich eine gewisse Ungenauigkeit im brigen Feuchtebereich Temperaturbereich Ablauf der 1 Punkt Feuchtekalibration 1 Punkt Temperaturkalibration 1 Vor Beginn der Kalibration den Jumper f r eine Feuchtekalibration auf CAL RH setzen f r eine Temperaturkalibration auf CAL T setzen 2 Positionierung des F hlers in der Referenzfeuchte Referenztempertur Kalibrationspunkt und Stabilisierung f r mindestens 30 min 3 TASTER S1 Kalibrationspunkt gt 50 r F gt 50 vom Temperaturmessbereich Durch mind 3 sek langes Dr cken wird die Routine gestartet Der Kalibrationsmode wird durch das Leuchten der LED D1 und durch das Symbol CAL gt im LCD Display angezeigt oder TASTER S2 Kalibrationspunkt 50 r F 50 vom Temperaturmessbereich Durch mind
50. s the calibration procedure will be ended without storing the calibration values Exiting the calibration mode is indicated by deactivation of the LED D1 and the symbol CAL on the LC display 1 point humidity calibration 1 point temperature calibration When the working range is limited to a certain more narrow range a calibration at one humidity point one temperature point is sufficient n accordance with the working range either the high or low calibration point should be selected CP gt or 50 RH CP gt or 50 of measurement value This calibration causes an extra inaccuracy for the rest of the working range 1 point humidity calibration procedure temperature calibration procedure 1 At the beginning of a humidity calibration set the jumper to CAL RH for a temperature calibration set the jumper to CAL T 2 Insert the sensor probe into the reference humidity reference temperature calibration point and stabilise for at least 30 minutes 3 BUTTON S1 Calibration point gt 50 RH gt 50 of measurement value Pressing the button for 3 seconds starts the procedure The calibration mode is indicated by the lit LED D1 and by the symbol CAL gt on the LC display or BUTTON S2 Calibration point lt 50 RH lt 50 of measurement value Pressing the button for 3 seconds starts the procedure The calibration mode is indicated by the lit LED D1 and by the symbol CAL on the LC display 4 BUT
51. t de 10mm 6mm l aide d une pince coupante 5 Souder le nouveau capteur d humidit avec le c t actif orient vers l int rieur voir sch ma 6 Visser pr cautionneusement le capuchon filtre le remplacer si encrass Etablir la connexion Effectuer une calibration d Humidit voir calibration d Humidit 2 points N Auto diagnostics via les LED de la carte de circuits imprim s D1 rouge D2 vert s allume durant toute la routine clignote pendant la mise en de calibration fonctionnement s allume bri vement lors du s allume lorsque le capteur Humidit recouvrement des param tres usines Temp rature est d fectueux Auto diagnostics et messages d erreur ERREUR cause possible gt Mesures Aide AFFICHAGE DE VALEURS INCORRECTES Erreur durant la recalibration du transmetteur gt R initialiser la calibration usine et r p ter la routine de calibration Filtre encrass Remplacer le filtre Capteur d fecteux Remplacer le capteur 31 Remplacement du fusible pour option V01 TEMPS DE REPONSE LONG Filtre encrass Remplacer le filtre Type de filtre incorrect Le type de filtre devra correspondre l application DEFAILLANCE DU TRANSMETTEUR pas de tension lectrique gt V rifier le cable et l alimentation lectrique VALEURS D HUMIDITE ELEVEES Ros e condensation sur la t te gt S cher la t te de la sonde et v rifier le de
52. t von vorne OUT 2 OUT2 1 Stecker f r 100 240V Bezeichnung Buchsenbelegung Metallgeh use Phase L1 l Ansicht von vorne Nulleiter N 3 Stecker f r 100 240V Bezeichnung Buchsenbelegung Kunststoffgeh use Phase L1 1 Ansicht von vorne Nulleiter N 3 Aussendurchmesser Versorgungsleitung 10 12mm Maximaler Leiterquerschnitt f r Anschlussleitung 1 5mm AWG 16 Die Uberstrom und Kurzschlussschutzeinrichtung der Versorgungsleitung muss f r einen Kabelquerschnitt von 0 8mm AWG 18 6A Sicherung ausgelegt werden Nationale Vorschriften f r die Installation sind einzuhalten Geh useunterteil und Geh usemittelteil m ssen beim Metallgeh use im Betriebszustand geerdet sein FEUCHTE TEMPERATUR TAUPUNKT FROSTPUNKT KALIBRATION A il unterer Kalibrationspunkt 2 D16 La s ss Taupunkt Frostpunktkalibrationen entsprechen dem Ablauf einer Feuchtekalibration Grundsatzlich stehen zwei Kalibrationsverfahren zur Verf gung 1 Punkt Feuchte Temperaturkalibration schnelle und einfache Kalibration bei einge schranktem Feuchte Temperaturarbeitspunkt 2 Punkt Feuchte Temperaturkalibration einfache Kalibration f r genaue Messergebnisse ber den gesamten Feuchte Temperaturarbeitsbereich Vor Kalibration empfiehlt es sich den Messumformer und die Kalibrationsvorrichtung z B HUMOR 20 mindestens 4h im selben temperaturstabilen Raum zu lagem um Temperaturunterschiede zu vermeiden Wahrend
53. tage oo TEERTEE oo ssotoo ld n 22 Z 8 Steckplatz f r optionales Display leuchtet w hrend der Kalibrations Routine andauernd leuchtet bei R cksetzung auf Werkskalibration kurz auf blinkt w hrend des Betriebs leuchtet bei defektem Feuchte Temperatur Sensor Taster f r 1 Pkt Feuchte Temperaturkalibration Feuchte gt 50 r F Taster f r 2 Pkt Feuchte Temperaturkalibration oberer Kalibrationspunkt Taster zum Speichern der Kalibrations Werte Taster f r 1 Pkt Feuchte Temperaturkalibration Feuchte lt 50 r F Taster f r 2 Pkt Feuchte Temperaturkalibration unterer Kalibrationspunkt Taster zum Verlassen der Kalibrations Routine ohne die Werte zu speichern f r R cksetzung auf Werkskalibration Einstellen des Schaltpunktes nur bei EE23 mit Schaltmodul 6 Hysteresis Potentiometer Einstellen der Hysterese nur bei EE23 mit Schaltmodul Angaben in mm INSTALLATION Polycarbonat gehause Montage fur Metall bzw Polycarbonatgehause 1 Montagebohrungen It Bohrplan siehe Zeichnungen ausf hren F r das Polycarbonatgehause steht zus tzlich ein Montageset f r Hutschienenmontage zur Verf gung siehe Zubeh r 2 Der Geh useunterteil wird mit 4 Schrauben montiert Schraubendurchmesser lt 4 2mm nicht im Lieferumfang enthalten 3 Anschluss des Messumformers siehe Elektrische Anschl sse 4 Montage von Mittelteil und Deckel mittels 4 Schrauben im Liefer
54. tion 1 EE90 3H Bride de montage 5mm HA010208 Seulement pour mod le H 32 CARACTERISTIQUES TECHNIQUES Donn es mesur es Humidit relative Capteur d humidit EE23 xA B Cx HC1000 200 EE23 xHx HC105 Gamme de mesure 0 100 HR Erreur de justesse incluant hyst r sis non lin arit et reproductibilit tracabilit aux talons intem tels que NIST PTB BEV LNE EE23 xA B Cx EE23 xHx 15 40 C lt 90 HR 1 3 0 3 de la valeur mesur e HR 1 8 0 3 de la valeur mesur e HR 15 40 C gt 90 HR 2 3 HR 2 8 HR 25 70 C 1 4 1 de la valeur mesur e HR 1 9 1 de la valeur mesur e HR 40 120 C 1 5 1 5 de la valeur mesur e HR Influence de la temp rature sur l lectronique typ 0 015 HR C Temps de r ponse avec filtre en grille m tallique 20 C tgy lt 15s Temp rature Capteur de temp rature EE23 xA B Cx Pt1000 class A DIN EN 60751 EE23 xHx Pt1000 class B DIN EN 60751 Gamme de mesure de la sonde EE23 xAx 40 60 C EE23 xBx 40 80 C EE23 xOx 40 120 0 EE23 xHx 40 80 C Erreur de justesse 7 LE 0 Sue Es EM U N RE EEE 0 ab so 2 0 10 20 30 40 so 60 70 80 ob wo 110 hao C db ab 2 10 d 10 20 30 40 50 60 70 a C Influence de la temp rature sur l lectronique typique 0 002 C C Sorties 0 1V 0 5 mA lt lt 0 5 mA 0 100 RH xx yy C
55. umfang enthalten Montagebohrung mit Rundloch 148 Modell A Wandmontage Montagebohrungen und Abmessungen f r Metall bzw Polycarbonatge hause siehe oben Messumformer der Serie EE23 xAx sind f r die Wandmontage ausgelegt Einsatzbereich F hler 40 60 C Einsatzbereich Elektronik 40 60 C Der Messumformer muss so montiert sein dass der Messf hler nach unten zeigt Modell B Kanalmontage Montagebohrungen und Abmessungen f r Metall bzw Polycarbonatge h use siehe oben Positionierung der Montagebohrung oben links zu Bohrung F hlerrohr Metallgeh use x 28 5mm y 37 5mm Polycarbonatgeh use x 20 5mm y 25 4mm Messumformer der Serie EE23 xBx sind f r die Kanalmontage ausgelegt Einsatzbereich F hler 40 80 C Einsatzbereich Elektronik 40 60 C Der Messumformer muss so montiert sein dass der Messf hler waagrecht oder nach unten in den Kanal ragt 7 2 Montageflansch 13 Edelstahl Z Tropfwasser Z schutz Al i Kai Abtropfbogen Vermeiden von Temperaturgefalle _ pinog V 85 entlang des Messf hlers Horizontale Montage Elektrische Anschl sse Ausgange und Stromversorgung Deckenmontage Montage Modell C Modell H abgesetzter F hler Montagebohrungen und Abmessungen f r Metall bzw Polycarbonatge hause siehe Seite 7 Messumformer der Serie EE23 xCx bzw EE23 xHx sind Messumformer
56. umidit Temp rature 2 points point de calibration sup rieure Bouton poussoir pour la sauvegarde des valeurs de calibration Bouton poussoir pour calibration Humidit Temp rature 1 point Humidit 50 HR Bouton poussoir pour calibration Humidit Temp rature 2 points point de calibration inf rieure Bouton poussoir pour la proc dure de calibration sans sauvegarde des valeurs de mesure pour le recouvrement des param tres usine R glage du seuil seulement avec le EE23 avec une sortie relais R glage de l hyst r sis seulement avec le EE23 avec une sortie relais 26 Dimensions en mm INSTALLATION Boitier polycarbonate Montage pour boitier m tallique ou polycarbonate 1 Percage des trous de montage selon le plan Un set de montage est disponible pour un montage encliquetable sur rail uniquement pour boitier polycarbonate voir Accessoires La partie basse du boitier est mont e par le biais de quatre vis non fournies 4 2mm Connexion du transmetteur voir Connexions lectriques Montage de la demi partie et du capot en utilisation quatre vis inclues Montage classique 148 Montage du mod le A Montage mural Pour le percage et les dimensions des boitiers m tallique ou polycarbo nate voir ci dessus Les transmetteurs S rie EE23 xAx sont concus pour un montage mural Gamme de fonctionnement de la sonde 40 60 C Gamme de fonctionn
57. x 250V AC 8A BS sauilde 7 28V DC 8A EEN d clenchement nf 4 Seuil Hyst r sis Ere cds Gamme de r glage 10 95 HR 3 15 HR Incertitude de r glage 3 HR 5 M 1 Se r f rer la gamme de fonctionnement du capteur d humidit 2 Les incertitudes d talonnage avec un coefficient d largissement k 2 2 fois l erreur standard sont inclus dans l erreur de justesse Les incertitudes sont calcul es selon EA 4 02 en tenant compte du GUM Guide to the seuil de 0 pp Lan d enclenchement lt 7 switching on co 50 expression of Uncertainty in Measurement Anl ee e LEVEL 3 Se r f rer la r f rence de commande 4 Voir la pr cision des fonctions de calcul 5 Conditions d utilisation de l alimentation V01 Cat gorie de surtension Il Niveau de pollution classe 2 I Altitude d installation jusqu 2000m au dessus du niveau de la mer i I gt 6 Connecteurs se reporter a la r f rence de commande 62 70 Seuil switching point 33 34 35 YOUR PARTNER IN SENSOR TECHNOLOGY ee lt i SS ELEKTRONIK Ges m b H HEAD OFFICE E E ELEKTRONIK Ges m b H Langwiesen 7 A 4209 Engerwitzdorf Austria Tel 43 7235 605 0 Fax 43 7235 605 8 info epluse com www epluse com TECHNICAL OFFICES E E CHINA BEJING Tel 86 10 84992361 info epluse cn www epluse cn E E CHINA SHANGHAI Tel 86 21 61176129 info epluse cn www epluse cn E E GERMANY Tel 49 6172 13881 0