1. 13 3 2 Duration of display 6 3 Calibration Certificate 13 Continuous operation 6 7 Servicing and Repairs 14 4 Functioning of the SECULIFE IM 7 4 1 Switching on Making Measurement 7 8 Specifications 14 4 2 Selecting the desired measuring unit CON OE TE odori nda aes 7 Declaration of conformity 17 4 3 Overload signal sssse 7 4 4 Memory functions cccceeeeeeeeeeeeeees 8 4 4 1 HOLD Display Hold Function 8 4 4 2 Mem Storing measurement value M MEMO 2 rennen 9 4 4 3 Mem Edit deleting a value in memory and enter a new value 10 4 4 4 Mem Recall Data Memory Recall 11 4 4 5 Mem Clear Clear memory 12 GMC I Gossen Metrawatt GmbH 1 Applications The SECULIFE IM Luminance Meter is a handy easy to use and high precision measuring instrument It allows the accurate measurement of the luminance in cd m or fL The SECULIFE IM is ideally suited for contact measurements with the light measuring probe placed direct on luminous or backlighted surfaces monitors TV sets light boxes light panels Monitors with the ambient light being taken into consideration in the measurement lighting and illumination of work stations streets airports museums projection screens The light senso
2. Instruction Manual Adapter disk 6 2 Calibration Certificate included Calibration reference Scientific Standard Lamps type Wi 41G of the PTB Physikalische Technische Bundesanstalt Braunschweig National Standard Institute of Germany Depending on how the instrument is being used we recommend a recalibration interval between 12 and 18 months For this purpose please contact our Calibration Service Department telephone 49 911 8602 172 7 Servicing and Repairs No special maintenance is required if the SECULIFE IM is handled correctly Keep the outside surfaces clean Use a slightly dampened cloth for cleaning Do not use cleansers abrasives or solvents Should the instrument nevertheless not work to your satisfaction or if you will require repeated calibration with Test Certificate please send the SECULIFE IM to GOSSEN Foto und Lichtmesstechnik GmbH Thomas Mann Strasse 16 20 D 90471 N rnberg GMC I Gossen Metrawatt GmbH 13 8 Technical Data Light Sensor Classification Measuring Rate LCD display Read out Overload signal Silicon photo diode with V A filter Class B according to DIN 5032 Part 7 CIE 69 2 measurements per second 50 mm x 25 mm 7 segments 3 digits 13 mm OL in the display Memory for measurement values 100 memory locations display indication FLL memory full Port Power Supply Battery Battery life Battery test External 14 USB 1 1 one 1 5 V alkali
3. Gossen Metrawatt GmbH 4 4 4 Mem Recall Data memory Recall Mem Start in the function Measuring and press the key Mem The last memory location filled will be indicated first Press one of the range keys to browse through the data memory The current memory location is indicated in the display i alternating with the measurement value stored in the memory By pressing any one of the other keys or when for about ten seconds no further memory data will be recalled with the Range keys the SECULIFE IM will return to the measuring function GMC I Gossen Metrawatt GmbH 4 4 5 Mem Clear Clear memory The SECULIFE IM must be in function HOLD When pressing simultaneously the Range keys you clear the complete measuring data memory The cancelling is confirmed by an acoustic signal and three dashes in the display HOLD 5 USB Port Standard Software The SECULIFE IM is equipped with a USB Port which allows the meter to be connected to a PC with the USB cable supplied The CD Rom supplied with the SECULIFE IM contains among other information a Standard Software which allows you to start the PC operation immediately More details about the PC operational functions are also available on that CD Rom 12 11 GMC I Gossen Metrawatt GmbH 6 Accessories 6 1 Standard Equipment SECULIFE IM incl Probe tube and cape safety housing transport case Battery Standard Software on CD ROM USB cable
4. leicht angefeuchteten Tuch Vermeiden Sie den Einsatz von Putz Scheuer oder L sungsmitteln Sollte Ihr SECULIFE IM einmal nicht zu Ihrer Zufriedenheit arbeiten oder wollen Sie Ihren Werkskalibrierschein erneuern lassen senden Sie ihn an GOSSEN Foto und Lichtmesstechnik GmbH Lina Ammon Str 22 90471 N rnberg GMC I Gossen Metrawatt GmbH 13 8 Technische Daten Lichtempfanger Silizium Fotodiode mit V A Filter Klassifizierung Klasse B nach DIN 5032 Teil 7 CIE 69 Messrate 2 Messungen pro Sekunde Digitalanzeige LCD Anzeigefeld 50 mm x 25 mm Anzeige Ziffernh he 7 Segment Ziffern 13 mm Stellenzahl 3 stellig Uberlaufanzeige OL wird eingeblendet Messwertspeicher 100 Speicherpl tze intern Anzeige FLL Speicher voll Schnittstelle USB 1 1 Stromversorgung Batterie 1 5V Mignon Alkali Mangan Zelle IEC LR 6 oder entsprechender Akku Betriebsdauer ca 45 Stunden Dauerbetrieb mit Alkali Mangan Batterie Batteriekontrolle Automatische Anzeige wenn die Batteriespannung ca 1 0V unterschreitet Bei PC Betrieb erfolgt die Stromversorgung ber die Schnittstelle Mechanischer Aufbau Geh use Kunststoff Abmessungen Messger t 65 x 120 x 19 mm ohne Bereitschaftstasche Messkopf 31 x 105 x 30 mm 14 GMC I Gossen Metrawatt GmbH Gewicht Messger t und kopf ca 265 g ohne Batterie Messsonde ffnung ca 18 5 mm Messfl che 6 5x6 5 mm Kabell nge ca 1 5 m gegen Aufpreis erh ltlich 3 m 5 m und 1
5. 0 m Elektromagnetische Vertr glichkeit EMV Nach Richtlinie 89 336 EWG vom 01 01 1996 Kennwerte SECULIFE IM Messgr e Messbereich Aufl sung Aufl sung in Candela m cd m in footLambert fL in cd m in fL Leuchtdichte LS 0 01 19 99 0 001 1 999 ea 0 1 1999 0 01 19 99 prp 1 3 999 0 1 199 9 IV 10 19990 1 1999 10 1 Wichtigste Fehlergrenzen beim SECULIFE IM Zul ssige Fehler Fehlergrenzen nach SECULIFE IM DIN 5032 Klasse B V A Anpassung f Linearit tsfehler f Abgleichfehler fs Gesamtfehler hes 10 lt 8 0 GMC I Gossen Metrawatt GmbH 15 Gedruckt in Deutschland Anderungen vorbehalten GMCI Gossen Metrawatt GmbH Thomas Mann Str 16 20 90471 N rnberg Telefon 0911 8602 0 Telefax 0911 8602 669 Email info gossenmetrawatt com 16 GMC I Gossen Metrawatt GmbH 2 GMC df GOSSEN METRAWATT SECULIFE IM Measuring Instrument for Luminance M688D 1 7 04 GMC I Gossen Metrawatt GmbH 1 USB Port Display Light measuring probe Key pad SECULIFE IM GMC I Gossen Metrawatt GmbH 1 APPlicallons ood a 4 2 DISPlay au 5 5 USB Port 2 1 The elements of the display 5 Standard Software 12 22 Kpag be MENS 5 6 Accessories 13 3 SECULIFE IM Operation 6 6 1 Standard equipment 13 9 1 PrepalkatlOliuca iis de td attore niente 6 6 2 Optional accessories
6. 3 Mem Edit Uberschreiben eines gespeicherten Messwerts 10 4 4 4 Mem Recall Auslesen des Messwertspeichers 11 4 4 5 Mem Clear L schen des gesamten Messwertspeichers 12 GMC I Gossen Metrawatt GmbH 1 Anwendung Mit dem Leuchtdichtemessger t SECULIFE IM haben Sie ein handliches bequem zu bedienendes und genaues Messger t erworben Das Ger t ist zur exakten Bestimmung der Leuchtdichte in den Einheiten cd m oder fL geeignet Mit SECULIFE IM k nnen Aufsatzmessungen Monitor Fernsehger t Leuchtpult Leuchtwanne an selbstleuchtenden Fl chen vorgenommen werden Der lichtempfindliche Sensor ist farbkorrigiert d h seine Spektralempfindlichkeit ist der spektralen Hellempfindlichkeit des menschlichen Auges V X angepasst Eine Klasseneinteilung f r Leuchtdichtemessger te ist in DIN 5032 Teil 7 festgelegt SECULIFE IM entspricht hierbei den Anforderungen der Klasse B Sie k nnen also alle wichtigen Lichtarten mit hoher Genauigkeit messen ohne Korrekturfaktoren ber cksichtigen zu m ssen Das Ger t besitzt einen Messwertspeicher mit 100 Speicherpl tzen der sowohl direkt ber Tastatur und Display als auch ber die eingebaute USB Schnittstelle und der im Lieferumfang enthaltenen Standard Software ausgelesen und weiterverarbeitet werden kann cd m Candela pro m 1 cd m 0 2919 fL 2 0 0929 cd ft fL footLambert 1fL 23 426 cd m 0 3183 cd
7. AUTO HOLD AUTO rt 41 Hold rt 41 UL UCLI UL UCLI The function HOLD is the basic function for all the memory functions GMC I Gossen Metrawatt GmbH 4 4 2 Mem Storing measurement value in memory Hold Mem GMC I Gossen Metrawatt GmbH The measurement value to be memorized is locked by the Hold key in the display By pressing the key Mem you will enter the value to be stored in the next free memory location An acoustic signal confirms value stored in memory The display indicates the stored measurement value alternating with the number of the memory location for a few seconds Subsequently the SECULIFE IM will return to the measuring function When the memory is completely filled the display will show FLL HOLD AUTO ve di C UL hte LL 00 4 4 3 Mem Edit Deleting a value in memory and entering a new value Hold The Mavolux offers the function Mem Edit for correcting a value stored in the memory Measure again press the Hold key and the new value is locked Then by pressing one of the range keys you can browse through the memory At the memory location to be corrected press now the key Mem An acoustic signal confirms value stored in memory In the display the measurement value stored is indicated for a few seconds alternating with the number of the memory location Subsequently the SECULIFE IM will return to Mem measuring function 10 GMC I
8. GmbH Anschrift Address Lina Ammon Str 22 90471 N rnberg Produktbezeichnung Product name Leuchtdichtemessger t Luminance Meter Typ Type SECULIFE IM Bestell Nr Order No M504G Das bezeichnete Produkt stimmt mit den Vorschriften folgender Europ ischer Richtlinien berein nachgewiesen durch die vollst ndige Einhaltung folgender Normen The above mentioned product has been manufactured according to the regulations of the following European directives proven through complete compliance with the following standards Nr No Richtlinie Directive 73 23 EWG Elektrische Betriebsmittel zur Verwendung Electrical equipment for use within certain voltage 73 23 EEC innerhalb bestimmter Spannungsgrenzen limits Niederspannungsrichtlinie Low Voltage Directive Anbringung der CE Kennzeichnung 2003 Attachment of CE mark 2003 EN Norm Standard IEC Deutsche Norm VDE Klassifikation Classification EN 61010 1 1993 IEC 61010 1 1992 VDE 0411 1 1994 EN 61557 3 1997 IEC 61557 3 1997 VDE 0413 3 1997 Nr No Richtlinie Directive 89 336 EWG Elektromagnetische Vertr glichkeit Electromagnetic compatibility 89 336 EEC EMV Richtlinie EMC directive Fachgrundform Generic Standard EN 61326 2002 N rnberg den 24 Juni 2004 Ort Datum Place date Vorsitzender der Gesch ftsf hrung Diese Erkl rung bescheinigt die bereinstimmung mit den genannten Richtlinien This declaration certifies compliance with the above
9. KOMETEC Karl Oelkers e K Mess und Pr fger te Shop Hungerberg 29 D 88085 Langenargen T 07543 913150 F 07543 913159 info kometec de www kometec de Sa nel GMC I A GOSSEN METRAWATT Operating Instructions SECULIFE IM Digitales Leuchtdichte Messgerat M688D 1 7 04 USB Display Schnittstelle Messkopf Tastenfeld Ger teansicht SECULIFE IM GMC I Gossen Metrawatt GmbH Inhaltsverzeichnis Seite Seite 1 Anwendung esses 4 2 Anzeigefeld 5 2 1 Das Anzeigefeld und seine Elemente 5 5 USB Schnittstelle 2 2 Tastenfeld xiu ice och ets 5 Standard Software 12 3 So funktioniert das SECULIFE IM 6 ZUBENOr ae 13 Sb VOrberellng make 6 6 1 Im Lieferumfang enthalten 13 3 2 Anzeigedauer Dauerbetrieb 6 6 2 Optionales Zubeh r 13 6 3 Eichzertifikat 13 4 Bedienung 7 4 1 Einschalten und Messen 7 7 Service Hinweis 14 4 2 Wahl der Anzeigeneinheit cd m fL 7 4 3 Uberlaufanzeige 7 8 Technische Daten 14 4 4 Speicherfunktionen 8 4 4 1 Hold Zwischenspeicher 8 Konformit tserkl rung 4 4 2 Mem Messwert speichern 9 4 4
10. ULIFE IM 3 1 Preparation First remove the snap on cover and open the battery compartment at the back of the meter Insert the battery included with the meter 1 5 V size AA IEC LR6 in the battery compartment Care should be taken to place the battery correctly according to the polarity indications and in the battery compartment When the battery warning symbol A appears in the display the battery must be replaced The values in the measurement data memory and also the preset individual values will be maintained even when the battery is changed 3 2 Duration of Display Continuous operation If for approx 4 minutes none of the keys of the SECULIFE IM is pressed the instrument will be switched off automatically During the last 4 seconds before automatic switch off an acoustic signal will sound By pressing any one of the keys you can override the automatic switch off When the instrument is switched off the values stored in the data memory and also the preset individual values will be maintained You can override the automatic switch off when switching on the instrument and simultaneously keep the HOLD key depressed The measuring unit cd m or fL in the display will blink and indicate that the continuous operation mode is on GMC I Gossen Metrawatt GmbH 4 Using the SECULIFE IM 4 1 Switching on Making Measurement Press the on off key and the SECULIFE IM is immediately in the measuring mode and is me
11. asuring at the rate of 2 times per second The instrument is in the function AUTO i e the SECULIFE IM will select the best suited measuring range for the existing light level By pressing one of the range keys one of the measuring ranges can be locked Browsing up or down through additional measuring ranges is accomplished by briefly pressing one of the range keys If both keys are pressed and held simultaneously the instrument is returned to AUTO RANGING 4 2 Selecting the desired measurement unit cd m or fL Use the key cd m fL to select the desired unit for the read out cd m or fL 4 3 Overload Display When exceeding one of the measuring ranges OL Overload appears in the display GMC I Gossen Metrawatt GmbH 7 4 4 Memory Functions The SECULIFE IM is provided in addition to the Display Hold also with amemory for data up to 100 measurement values This function allows several measurement operations in the field and read out at a later time The data stored in the memory will be maintained even when the instrument is turned off or the battery is changed 4 4 1 HOLD Display Hold Function The display HOLD function allows you to measure even at very low light levels where it would be difficult to read the display By pressing the HOLD key the last value measured is held on the display to be read at brighter light Pressing the HOLD key again will return the SECULIFE IM to the measuring function
12. em Anzeige Zwischenspeicher noch einen Messwertspeicher mit 100 Speicherpl tzen Diese Funktion erm glicht Ihnen mehrere Messungen vor Ort vorzunehmen und zu einem sp teren Zeitpunkt auszulesen Die gespeicherten Werte bleiben bei Ausschalten des Ger tes oder bei einem Batteriewechsel erhalten 4 4 1 Hold Zwischenspeicher Um Ihnen z B die M glichkeit zu geben in dunkler Umgebung zu messen und anschlie end im Hellen den Messwert abzulesen hat das SECULIFE IM einen Anzeige Zwischenspeicher Bei Druck auf die Taste Hold wird die letzte Messung im Display festgehalten Im Display erscheint HOLD Durch erneuten Druck auf die Taste Hold wechselt das SECULIFE IM wieder in die Messfunktion HOLD AUTO Hold AL cd m u Ba U u Bu Die Funktion Hold ist die Ausgangsfunktion f r alle Speicherfunktionen GMC I Gossen Metrawatt GmbH 4 4 2 Mem Messwert speichern Hold HOLD AUTO ALL a edim at IL Mem Der zu speichernde Messwert ist im Display festgehalten Durch Dr cken der Taste Mem wird der zu speichernde Wert auf den n chsten freien Speicherplatz abgelegt Zur Best tigung der Speicherung erfolgt ein Signalton Im Display wird der gespeicherte Messwert abwechselnd mit der Nummer des Speicherplatzes f r einige Sekunden angezeigt Anschlie end wechselt das SECULIFE IM wieder in die Messfunktion Ist der Messwertspeicher vollst ndig belegt wird dies mit FLL im Display an
13. ft 1 cd ft 10 76 cd m 3 142 fL A GMC I Gossen Metrawatt GmbH Anzeigefeld 2 1 Das Anzeigefeld und seine Elemente 5 4 D AUTO x1000 AI N x cd m A Li i Hi Messwert und Speicheranzeige Messeinheit Zwischenspeicher Faktor Messwert Auto Range automatische Messbereichswahl Batteriewarnanzeige OO POD GMC I Gossen Metrawatt GmbH 2 2 Tastenfeld OORUN ND WEB Auto cd m tL Range Mem on off Ein Ausschalten Rangetaste Speicher Messbereich 4 cd m fL Messeinheit umschalten Hold Zwischenspeicher Rangetaste Speicher Messbereich y Mem Speichertaste 3 So funktioniert das SECULIFE IM 3 1 Vorbereitung Setzen Sie zuerst die beiliegende Batterie 1 5V Mignon Batterie IEC LR6 in die Batteriekammer ein Offnen Sie hierzu den Schnappverschlu des Batteriefachs an der R ckseite des SECULIFE IM Achten Sie dabei auf die richtige Polarit t Die Polungsrichtung ist durch einen Pr gedruck in der Batteriekammer gekennzeichnet Ist die Kapazit t der Batterie ersch pft werden Sie durch die Anzeige 4K im Display gewarnt Bei einem Batteriewechsel bleiben die im Messwertspeicher abgelegten Werte sowie die individuellen Einstellungen erhalten 3 2 Anzeigedauer Dauerbetrieb Falls f r ca 4 Minuten keine Bedientaste des SECULIFE IM gedr ckt wird schaltet das Ger t automatisch ab Die letzten 4 Sekunden vor der automatischen Abschaltung werden mit la
14. gezeigt AUTO Com l 4 al GMC I Gossen Metrawatt GmbH 4 4 3 Mem Edit berschreiben eines gespeicherten Messwert Hold Um einen irrt mlich im Messwertspeicher abgelegten Wert zu korrigieren hat das SECULIFE IM die Funktion Mem Edit Sie messen den zu korrigierenden Messwert neu und halten diesen mit der Taste Hold fest Durch Druck auf eine t der Range Tasten kann durch den Speicher geblattert werden Bei dem zu Uberschreibenden Speicherplatz drucken Sie jetzt die Taste Mem Zur Bestatigung der Speicherung erfolgt ein Signalton Im Display wird der gespeicherte Messwert abwechselnd mit der Nummer des Speicherplatzes f r einige Sekunden Mem angezeigt Anschlie end wechselt das SECULIFE IM wieder in die Messfunktion 10 GMC I Gossen Metrawatt GmbH 4 4 4 Mem Recall Auslesen des Messwertspeichers Ausgehend von der Funktion Messen dr cken Sie Mem die Taste Mem Es wird der letzte belegte Speicherplatz zuerst angezeigt Durch Druck auf eine der Range Tasten kann durch den Speicher gebl ttert werden Der aktuelle t Speicherplatz wird abwechselnd mit dem gespeicherten Messwert angezeigt Durch Druck auf eine beliebige andere Taste oder wenn Sie ca 10 Sekunden keinen weiteren Speicher Uber die Range Tasten abrufen gelangen Sie wieder in die Messfunktion GMC I Gossen Metrawatt GmbH 11 4 4 5 Mem Clear L schen des gesamten Messwertspeichers Da
15. mentioned beinhaltet jedoch keine Zusicherung von Eigenschaften Die Sicherheitshinweise directives but does not include a property assurance The safety der mitgelieferten Produktdokumentationen sind zu beachten notes given in the product documentations which are part of the supply must be observed GMC I Gossen Metrawatt GmbH 17 Printed in Germany Subject to change witout notice GMC I Gossen Metrawatt GmbH Thomas Mann Str 16 20 D 90471 N rnberg Phone 449 911 8602 0 Fax 49 911 8602 663 e mail info gossenmetrawatt de 18 GMC I Gossen Metrawatt GmbH
16. ne manganese cell size AA IEC LR 6 or suitable rechargeable battery approx 45 hours continuous operation with alcaline manganese battery Automatic display of symbol when battery voltage drops below 1 0 Volts When the SECULIFE IM is connected to a PC power will be supplied by the PC via the USB cable GMC I Gossen Metrawatt GmbH Weights and Dimensions Housing Plastics Dimensions Measuring instrument 65 x 120 x 19 mm 2 56 x 4 73 x 75 without carrying case Measuring Probe 31 x 105 x 30 mm Weight Measuring instrument with measuring probe approx 265 g without battery Measuring probe Aperture approx 18 5 mm Sensor surface area 6 5 x 6 5 mm Length of cable approx 1 5 m available in 3m 5m and 10 meters on special order Electromagnetic Compatibility EMC The SECULIFE IM meets the Specifications 89 336 EWG dt 01 01 1996 GMC I Gossen Metrawatt GmbH 15 Characteristics SECULIFE IM in Candela m cd m in footLambert fL in cd m in fL Luminance D f 00t 19 99 0 001 1 999 00 0 001 a f 04 1999 0 01 1999 01 0 01 My Aa 1999 0 1 199 9 10 19990 V A Matching f 696 3 096 Linearity f Adjustment Error fi Total Error fes 16 GMC I Gossen Metrawatt GmbH EG KONFORMIT TSERKL RUNG C DECLARATION OF CONFORMITY GOSSEN Dokument Nr Document No 103 2004 Hersteller Manufacturer GOSSEN Foto und Lichtmesstechnik
17. ngen Signalt nen gekennzeichnet durch Druck auf eine beliebige Taste k nnen Sie die Abschaltung unterbinden Beim Ausschalten des Ger ts bleiben die im Messwertspeicher abgelegten Werte sowie die individuellen Einstellungen erhalten Die automatische Abschaltung l sst sich unterdr cken wenn Sie beim Einschalten zus tzlich die Taste Hold gedr ckt halten Der Dauerbetrieb wird Ihnen im Display durch Blinken der Messeinheit angezeigt GMC I Gossen Metrawatt GmbH 4 Bedienung 4 1 Einschalten und Messen Schalten Sie das Ger t durch Dr cken der Taste on off ein Das SECULIFE IM ist sofort in Messbereitschaft und misst 2 mal pro Sekunde Nach dem Einschalten befindet sich das Messger t im Messbereich Auto d h entsprechend des Lichtniveaus schaltet das SECULIFE IM in den g nstigsten Messbereich Durch Druck auf eine der Range Tasten l sst sich einer der Messbereiche fixieren Durch weiteren kurzen Druck auf eine der Range Tasten werden die Messbereiche auf oder abw rts weiter geschaltet Durch gleichzeitiges Dr cken beider Tasten k nnen Sie wieder auf Messbereichsautomatik umstellen 4 2 Wahl der Anzeigeneinheit cd m fL Mit der Taste cd m fL kann die gew nschte Anzeigeeinheit Candela m oder footLambert gew hlt werden 4 3 berlaufanzeige Bei berschreiten eines Messbereichs erscheint OL overload im Display GMC I Gossen Metrawatt GmbH 7 4 4 Speicherfunktionen Das SECULIFE IM besitzt neben ein
18. r is color corrected i e its spectral responsitivity has been matched to the spectral photonic vision of the human eye V A The accuracy class for luminance meters has been defined in the Standard Specification DIN 5032 Part 7 The SECULIFE IM fully complies with the requirements of Class B Consequently all the important types of light can be measured with high precision without the necessity to apply additional corrrection factors The SECULIFE IM is provided with a data memory with 100 measurement value locations which can be read and processed direct with the keys and display but also through the integrated USB Port and the standard software provided with the instrument cd m Candela per m 1 cd m 0 2919 fL 0 0929 cd ft fL footLambert 1fL 23 426 cd m 0 3183 cd ft 1 cd ft 10 76 cd m 3 142 fL GMC I Gossen Metrawatt GmbH 2 Display 2 1 Description of display 3 5 4 l l HOLD AUTO x1000 Tu Eun um UL a 6 1 Display of measured value and Memory indication Measurement Unit Display HOLD indication Multiplying factor for measurement value Auto ranging automatic range selection Low Battery oor WP GMC I Gossen Metrawatt GmbH cd m fL mess Mem Auto on off Hold Range Switching on off Range key Memory Measuring range 4 cd m fL Select measurement unit Hold Function Range key Memory Measuring range Mem Memory key 3 Functioning of the SEC
19. s SECULIFE IM mu sich in der Funktion HOLD befinden Durch gleichzeitiges Dr cken der Range Tasten wird der gesamte Messwertspeicher gel scht Die L schung wird durch einen Signalton sowie im Display durch 3 Striche best tigt HOLD 5 USB Schnittstelle Standard Software Das SECULIFE IM besitzt eine USB Schnittstelle Diese erm glicht die Verbindung zum PC ber das mitgelieferte USB Kabel Auf der dem SECULIFE IM beiliegenden CD ROM befindet sich u a eine Standard Software mit der Sie sofort in den PC Betrieb einsteigen k nnen N here Informationen zum PC Betrieb finden Sie ebenfalls auf dieser CD ROM 12 GMC I Gossen Metrawatt GmbH 6 Zubeh r 6 1 Im Lieferumfang enthalten Messger t inkl Gummischutzh lle mit Mess Sonde und Abdeckkappe Rohr f r Mess Sonde z CD ROM USB Kabel Bedienungsanleitung Adapterscheibe Batterie 6 2 Werkskalibrierschein im Lieferumfang enthalten Die R ckf hrung der Messergebnisse wird ber die Wissenschaftliche Normallampe Wi 41G An das Nationale Normal der PTB in Braunschweig gew hrleistet Je nach Einsatz des Ger tes empfehlen wir ein Kalibrierintervall von 12 bis 18 Monaten Wenden Sie sich hierzu bitte an unseren Kalibrierservice Telefon 0911 8602 172 7 Service Hinweis Das Ger t ben tigt bei vorschriftsm igem Gebrauch keine besondere Wartung Sollte das Ger t durch den Gebrauch verschmutzt worden sein reinigen Sie die Geh useoberfl che mit einem