Home

MH-8990 - Monacor

image

Contents

1. MONACOR INTERNATIONAL 2 Important Notes The microphone corresponds to all required directives of the EU and is therefore marked with CE The microphone is suitable for indoor use only Pro tect it against dripping water and splash water high air humidity and heat admissible ambient tempera ture range 0 40 C e For cleaning only use a dry soft cloth never use chemicals or water e No guarantee claims for the microphone and no lia bility for any resulting personal damage or material damage will be accepted if the microphone is used for other purposes than originally intended if it is not correctly operated or not repaired in an expert way 2 If the microphone is to be put out of operation definitively take it to a local recycling plant for a disposal which is not harmful to the envi ronment Dead batteries or defective rechargeable batteries do not belong in the household rubbish always take them to a special waste disposal e g collecting con tainer at your retailer 3 Applications Together with the multifrequency receiver US 1000D from JTS this dynamic hand held microphone with integrated multifrequency transmitter makes up a wire less audio transmission system For adjusting the transmission frequency two modes are available to ensure maximum flexibility 1 In the group mode the wireless microphone oper ates with four transmission groups A D to which 16 transmiss
2. the thread of the microphone body and screw it on 5 Setting the Microphone into Operation 1 Before switching on the microphone set the receiv er to an interference free transmission channel see instruction manual of the receiver 2 Then switch on the microphone Set the POWER switch 9 at the lower end of the microphone to the position POWER If required slide the safety cap 10 downwards beforehand The display 3 will indicate the transmission group adjusted with the corresponding transmission channel in the group mode e g H or the transmission frequency in the frequency mode and a battery symbol 2 showing the current charging status of the batteries in several steps tai gt Mn gt I fully charged exhausted If the batteries are exhausted indication __ the colour of the display on the receiver will additionally change from green to orange as a warning 3 The keys 4 6 which are slightly recessed are easily actuated by means of the tip of your thumb 4 Set the microphone to the same transmission group and the same transmission channel or the same radio frequency adjusted on the receiver chapter 5 1 or chapter 5 2 5 Speak sing into the microphone The mute switch 11 must be in the position OFF otherwise no audio signal will be transmitted The volume level of the microphone can be readjusted by modification of the sensitivity chapter 5 3 6 The microphone can
3. be locked to prevent acciden tal modification of the adjustments or switching off chapter 5 4 7 For short interruptions the signal transmission can be muted so that no interference will occur chap ter 5 5 5 4 Locking Unlocking the microphone With the microphone locked it is not possible a to switch off the microphone if the POWER switch 9 is set to OFF with the microphone locked the display will show Lac Hn b to call the adjusting modes for group channel fre quency and sensitivity 5 4 1 Activating the locking function 1 Keep the key SET 6 pressed for 2s then shortly press the key SET another four times so that the indication Lac HFF lock deactivated starts flashing on the display 2 Press the key A 5 Loc n starts flashing on the display 3 To memorize the adjustment press the key SET The display will shortly indicate 5tar the adjusting mode will be exited and the microphone will go to normal operation 5 4 2 Deactivating the locking function 1 The POWER switch 9 must be set to POWER 2 Keep the key SET 6 pressed for 3s until Loc tn starts flashing on the display 3 Press the key V 4 display Loc HFF starts flashing on the 4 To memorize the adjustment press the key SET The display will shortly indicate 5tar the adjusting mode will be exited and the microphone will go to normal operation 5 5 Mute function The mute function serves for short muting of the
4. channel With the key V the channels will be scanned in descending order with the key A they will be scanned in ascending order gt 5 To memorize the adjustment press the key SET The display will shortly show 5torE the adjusting mode will be exited and the microphone will go to normal operation 790 625 791 125 791 875 793 625 795 875 797 125 797 875 799 125 800 875 801 375 802 875 03 375 04 125 806 250 807 625 813 625 ajeje 790 87 790 750 791 125 792 62 791 375 791 750 5 625 625 875 803 A 8 0 5 806 807 OQ Fig 4 Transmission frequencies in MHz of the groups and channels E MONACOR INTERNATIONAL In other countries different legal regulations may apply for wireless systems operating in this frequency range Therefore please contact the MONACOR subsidiary or the corresponding authorities of the country prior to setting the system into operation outside Germany 4 Power Supply Only insert batteries of the same type and always replace all batteries f the microphone is not used for a longer period e g more than a week remove the batteries Thus the microphone will not be damaged in case of battery leakage 1 Unscrew the cap 7 for the battery compartment 2 Insert two 1 5V batteries of size AA R6 with the positive and negative connections as indicated on the holder 3 Place the battery compartment cap straight against
5. signal transmission throat clearing mode or enquiry mode with subsequent immediate readiness for operation without delay 1 Set the MUTE switch 11 at the lower end of the microphone to the position MUTE If required slide the safety cap 10 upwards beforehand 2 To continue the signal transmission set the MUTE switch to the position OFF Note In the switch position MUTE there will be no speech transmission however the microphone will still be in the transmission mode and con sume power Therefore always switch off the microphone with the POWER switch 9 posi tion OFF for longer interruptions 5 2 Adjusting the transmission frequency 1 Keep the key SET 6 pressed for 2 s until either the indication MHz or the group indication A b L or d starts flashing on the display If the group indication starts flashing shortly actuate the key SET twice again to go to the frequency adjusting mode Note To exit the adjusting mode without making an adjustment press the key SET so many times until the display shows LAnLEL The microphone will then return to normal operation 2 Use the cursor keys to adjust the frequency Each time the key V 4 is pressed the frequency will be decreased by 25kHz each time the key A 5 is pressed it will be increased by 25 kHz To scan a wide frequency range keep the corresponding key pressed Note If several wireless transmission systems are operated at the same
6. time the radio frequencies of the individual systems should be carefully matched to each other to prevent interference Examples for frequencies for simultaneous op eration of several systems can be found in the Internet on www jts germany de under Informa tionen Intermodulationsfreies Frequenzsetup 3 To memorize the adjustment press the key SET The display will shortly indicate 5tar the adjusting mode will be exited and the microphone will go to normal operation 5 3 Adjusting the sensitivity 1 Keep the key SET 6 pressed for 2 s then shortly press the key SET another three times so that the display will indicate the current sensitivity O dB 6 dB 12 dB or 24 dB Note To exit the adjusting mode without making an adjustment press the key SET so many times until the display shows LAnLEL The microphone will then return to normal operation 2 Adjust the sensitivity according to the indication AF on the display of the receiver in such a way to obtain an optimum volume level of the microphone If the volume is too high the microphone will distort in this case adjust a lower value with the key V 4 If the volume is too low there will be a poor signal noise ratio in this case adjust a higher value with the key A 5 3 To memorize the adjustment press the key SET The display will shortly indicate 5tar the adjusting mode will be exited and the microphone will go to normal operation JTS ENGLI
7. zum Abdecken des Schalters der gegen unbeabsichtigtes Verstellen gesch tzt werden soll 11 Mute Schalter zur kurzen st rungsfreien Unter brechung R usper bzw R ckfrage Modus und anschlie ender sofortiger Betriebsbereitschaft ohne Zeitverz gerung 12 4 poliger Steckkontakt jeweils an der Mikrofon kapsel Abb 2 und am Handteil Abb 3 vor dem Zusammenschrauben von Mikrofonkapsel und Handteil die Kontakte ineinanderstecken JTS DEUTSCH DEUTSCH 7 Die Signal bertragung l sst sich f r kurze Unterbre chungen st rungsfrei stumm schalten Kap 5 5 8 Der Kennzeichnungsring 8 kann auch gegen einen der beiliegenden farbigen Ringe ausgetauscht wer den Mehrere Systeme mit unterschiedlichen Funk frequenzen lassen sich so farblich codieren 9 Zum Ausschalten des Mikrofons nach dem Betrieb den Ein Ausschalter 9 auf OFF stellen 5 1 Einstellen der Sendegruppe und des ber tragungskanals 1 Die Taste SET 6 2s gedr ckt halten bis im Dis play entweder die Anzeige MHz blinkt oder die Gruppenanzeige f b L oder d Blinkt die Anzeige MHz die Taste SET noch einmal kurz bet tigen um in den Gruppeneinstellmodus zu gelangen Hinweis Um den Einstellmodus ohne eine Einstel lung zu verlassen die Taste SET so oft dr cken bis im Display LAnLEL erscheint Das Mikrofon schaltet danach auf normalen Betrieb zur ck Mit den Pfeiltasten die Sendegruppe einstellen mit der Tas
8. MONACOR INTERNATIONAL J 1 CJ Vertrieb von JTS Produkten Distribution of JTS products Bedienungsanleitung Instruction Manual MH 8990 Mikrofon mit UHF Sender Microphone with UHF Transmitter JTS Bevor Sie einschalten Wir w nschen Ihnen viel Spa mit Ihrem neuen Ger t von JTS Bitte lesen Sie diese Bedie nungsanleitung vor dem Betrieb gr ndlich durch Nur so lernen Sie alle Funktionsm glich keiten kennen vermeiden Fehlbedienungen und sch tzen sich und Ihr Ger t vor eventuellen Sch den durch unsachgem en Gebrauch Heben Sie die Anleitung f r ein sp teres Nach lesen auf Der deutsche Text beginnt auf der Seite 4 Before switching on We wish you much pleasure with your new JTS unit Please read these operating instruc tions carefully prior to operating the unit Thus you will get to know all functions of the unit operating errors will be prevented and yourself and the unit will be protected against any damage caused by improper use Please keep the operating instructions for later use The English text starts on page 8 DEUTSCH ENGLISH T i a a ai ae aL ol E att A
9. SH 10 ENGLISH 11 7 Specifications Type of unit dynamic hand held micro phone with PLL multifre quency transmitter Directivity hypercardioid Radio frequency range 790 814 MHz Audio frequency range 50 16 000 Hz Frequency stability 0 005 Transmitting power 10mW EIRP Ambient temperature 0 60 Power supply two 1 5V batteries of size AA R6 Dimensions 53mm x 245mm Weight 360g Subject to technical modification 6 Replacement Microphone Cartridge The microphone cartridge 1 can be replaced by the capacitor microphone cartridge DMC 8000 6 by JTS which offers a supercardioid characteristic and a wider frequency range 50 18000 Hz 1 Unscrew the microphone cartridge 1 2 Place the replacement microphone cartridge on the handle in such a way that the 4 pole contacts 12 of the cartridge and of the handle fit into each other then screw the cartridge on the handle All rights reserved by MONACOR INTERNATIONAL GmbH amp Co KG No part of this instruction manual may be reproduced in any form or by any means for any commercial use E P MONACOR INTERNATIONAL www jts germany de Copyright by MONACOR INTERNATIONAL GmbH amp Co KG Bremen Germany All rights reserved A 0627 99 01 06 2006
10. a ee ee ee ee ee He FEAT EEE ee a SR et PED AIEEE x A Fi ag a 2 Wichtige Hinweise f r den Gebrauch Das Mikrofon entspricht allen erforderlichen Richt linien der EU und ist deshalb mit C gekennzeichnet e Das Mikrofon ist nur zur Verwendung im Innenbe reich geeignet Sch tzen Sie es vor Tropf und Spritzwasser hoher Luftfeuchtigkeit und Hitze zu l ssiger Einsatztemperaturbereich 0 40 C e Verwenden Sie f r die Reinigung nur ein trockenes weiches Tuch niemals Chemikalien oder Wasser e Wird das Mikrofon zweckentfremdet falsch bedient oder nicht fachgerecht repariert kann keine Haftung f r daraus resultierende Sach oder Personensch den und keine Garantie f r das Mikrofon bernom men werden genommen werden bergeben Sie es zur umweltgerechten Entsorgung einem rtli E chen Recyclingbetrieb Werfen Sie verbrauchte Batterien bzw defekte Akkus nicht in den Hausm ll sondern geben Sie sie nur in den Sonderm ll z B Sammelbeh lter bei Ihrem Soll das Mikrofon endg ltig aus dem Betrieb Einzelh ndler 3 Einsatzm glichkeiten Dieses dynamische Handmikrofon mit integriertem Multifrequenz Sender bildet mit d
11. automatically be extinguished approx 10 s after the last actuation of a key 4 Key V for scanning the transmission group chan nel in descending order in the group adjusting mode channel adjusting mode for decreasing the frequency in the frequency adjusting mode or the sensitivity in the sensitivity adjusting mode and for deactivating the locking function in the lock adjusting mode 5 Key A for scanning the transmission group chan nel in ascending order in the group adjusting mode channel adjusting mode for increasing the frequency in the frequency adjusting mode or the sensitivity in the sensitivity adjusting mode and for activating the locking function in the lock ad justing mode 6 Key SET with the microphone not locked to call and exit the adjusting modes for transmis sion group channel frequency sensitivity locking function chapters 5 1 5 2 5 3 and 5 4 1 with the microphone locked to call and exit the adjusting mode for the locking function chapter 5 4 2 7 Cap for the battery compartment to insert or replace the batteries 2 x 1 5 V batteries of size AA unscrew the cap 8 Identification ring can be replaced by one of the colour coded rings supplied 9 Power switch 10 Safety cap for covering the switch to be protected against accidental readjustment 11 Mute switch for short muting throat clearing mode or enquiry mode with subsequent imme diate readiness for operati
12. autst rke ergibt sich ein schlech ter Rauschabstand dann mit der Taste A 5 einen h heren Wert einstellen Die Einstellung durch Dr cken der Taste SET spei chern Im Display erscheint kurz Stor der Ein stellmodus wird verlassen und das Mikrofon wech selt auf den Normalbetrieb gt Z STS DEUTSCH DEUTSCH 7 Technische Daten Ger tetyp dynamisches Handmikrofon mit PLL Multifrequenz Sender Richtcharakteristik Hyperniere Funkfrequenzbereich 790 814 MHz Audiofrequenzbereich 50 16 000 Hz Frequenzstabilit t 0 005 Sendeleistung 10 mW EIRP Einsatztemperatur O 40 C Stromversorgung zwei 1 5 V Batterien der Gr e Mignon R6 AA Abmessungen O 53 mm x 245mm Gewicht 360g Anderungen vorbehalten C 6 Austausch Mikrofonkapsel Die Mikrofonkapsel 1 l sst sich gegen die Konden sator Mikrofonkapsel DMC 8000 6 von JTS austau schen Diese hat eine Supernieren Richtcharakteristik und einen gr eren Frequenzbereich 50 18000 Hz 1 Die Mikrofonkapsel 1 abschrauben 2 Die Austausch Mikrofonkapsel so auf das Handteil setzen dass die 4 poligen Steckkontakte 12 von Kapsel und Handteil ineinanderfassen dann die Kapsel auf das Handteil schrauben Diese Bedienungsanleitung ist urheberrechtlich f r MONACOR INTERNATIONAL GmbH amp Co KG gesch tzt Eine Reproduktion f r eigene kommerzielle Zwecke auch auszugsweise ist untersagt E
13. em Multifrequenz Empf nger US 1000D von JTS ein drahtloses Audio bertragungssystem Zum Einstellen der Sendefre quenz stehen zwei Modi zur Verf gung um h chste Flexibilit t zu gew hrleisten 1 Im Gruppenmodus arbeitet das Funkmikrofon mit vier Sendegruppen A D denen jeweils 16 ber tragungskan le zugeordnet sind Insgesamt stehen also 64 werkseitig eingestellte bertragungskan le zur Verf gung Diese Kan le im UHF Bereich von 790 814 MHz k nnen frei ausgew hlt werden 2 Im Frequenzmodus l sst sich die Sendefrequenz innerhalb des UHF Bereichs 790 814 MHz frei ausw hlen Frequenzraster 25 kHz Zum Lieferumfang geh ren ein Mikrofonkoffer ein Mikrofonhalter und farbige aufsteckbare Kunststoff ringe zur Kennzeichnung des Mikrofons 3 1 Konformit t und Zulassung des Funk mikrofons Das Funkmikrofon ist nach den einschl gigen Normen der R TTE Richtlinie gepr ft Die Konformit tser klarung kann im Internet auf der Homepage von JTS abgerufen werden www jts germany de Der Frequenzbereich 790 814 MHz ist in Deutsch land allgemein zugeteilt die Allgemeinzuteilung ein zelner Frequenzen des Bereichs ist jedoch an die Art der Nutzung gebunden Das Funkmikrofon ist dement sprechend anmelde und gebuhrenfrei sofern bei der Wahl der Sendefrequenz die Vorgaben der Verf gung 91 2005 beachtet werden Sie finden die Verf Bitte klappen Sie die Seite 3 heraus Sie sehen dann immer die beschriebenen Bedie
14. en Im Display blinkt 4 Die Einstellung durch Dr cken der Taste SET spei chern Im Display erscheint kurz 5tor der Ein stellmodus wird verlassen und das Mikrofon wech selt auf den Normalbetrieb 5 5 Mute Funktion Die Mute Funktion dient zur kurzen st rungsfreien Unterbrechung der Signal bertragung R usper bzw R ckfrage Modus und anschlie ender soforti ger Betriebsbereitschaft ohne Zeitverz gerung 1 Den Schalter MUTE 11 unten am Mikrofon in die Position MUTE stellen Gegebenenfalls vorher die Sicherungskappe 10 nach oben schieben 2 Zum Fortfahren der Signal bertragung den Schal ter MUTE in die Position OFF stellen Hinweis In der Schalterposition MUTE wird keine Sprache bertragen das Mikrofon befindet sich aber weiterhin im Sendemodus und verbraucht Energie Bei l ngeren Unterbrechungen daher unbedingt das Mikrofon mit dem Ein Ausschal ter 9 abschalten Position OFF 5 2 Einstellen der Sendefrequenz 1 Die Taste SET 6 2s gedr ckt halten bis im Dis play entweder die Anzeige MHz blinkt oder die Gruppenanzeige f b L oder d Blinkt die Gruppen anzeige die Taste SET noch zweimal kurz bet ti gen um in den Frequenzeinstellmodus zu gelan gen Hinweis Um den Einstellmodus ohne eine Einstel lung zu verlassen die Taste SET so oft dr cken bis im Display LAnLEL erscheint Das Mikrofon schaltet danach auf normalen Betrieb zur ck 2 Mit den Pfeiltasten die Freq
15. iche Sendegruppe und den gleichen bertragungskanal oder auf die gleiche Funkfrequenz wie am Empf nger einstellen Kapitel 5 1 bzw Kapitel 5 2 In das Mikrofon sprechen bzw singen Der Mute Schalter 11 muss in der Position OFF stehen anderenfalls wird kein Audiosignal bertragen Durch Ver ndern der Empfindlichkeit l sst sich der Laut st rkepegel des Mikrofons korrigieren Kap 5 3 Das Mikrofon kann gesperrt werden um ein verse hentliches Ver ndern der Einstellungen oder um ein Ausschalten zu verhindern Kap 5 4 2 2 2 5 4 Mikrofon sperren entsperren Bei gesperrtem Mikrofon ist es nicht m glich a das Mikrofon auszuschalten wird bei gesperrtem Mikrofon der Ein Ausschalter 9 auf OFF gestellt zeigt das Display Loc Un b die Einstellmodi f r Gruppe Kanal Frequenz und Empfindlichkeit aufzurufen 5 4 1 Sperrfunktion aktivieren 1 Die Taste SET 6 2s gedr ckt halten danach die Taste SET noch viermal kurz dr cken sodass im Display toc HFF blinkt Sperrung deaktiviert 2 Die Taste A 5 dr cken Im Display blinkt L oc lin 3 Die Einstellung durch Dr cken der Taste SET spei chern Im Display erscheint kurz 5tor der Ein stellmodus wird verlassen und das Mikrofon wech selt auf den Normalbetrieb 5 4 2 Sperrfunktion deaktivieren 1 Der Ein Ausschalter 9 muss auf POWER stehen 2 Die Taste SET 6 3s gedr ckt halten bis toc Un im Display blinkt 3 Die Taste V 4 dr ck
16. ion channels are assigned respec tively i e altogether 64 factory set transmission channels are available These channels in the UHF range of 790 814 MHz can be selected as desired 2 In the frequency mode the transmission frequency within the UHF range of 790 814 MHz can be se lected as desired frequency spacing 25 kHz The microphone is supplied with a microphone case a microphone holder and coloured push on plastic rings for identification of the microphone 3 1 Conformity and approval of the wireless microphone The wireless microphone has been tested according to the relevant standards of the R T TE directive The declaration of conformity can be found in the Internet on the JTS home page www jts germany de In the Federal Republic of Germany the frequency range of 790 814 MHz is generally assigned how ever the general assignment of individual frequencies of the range is subject to the type of use see the direc tive 91 2005 on the home page of the Bundesnetza gentur Federal Network Agency www bundesnetzagentur de Please unfold page 3 Then you can always see the operating elements described 1 Operating Elements 1 Microphone cartridge 2 Battery status indication 3 Indication of the transmission frequency or the trans mission group and the transmission channel fig 4 After switching on the microphone and when actuating the keys 4 6 the display background illumination will light up It will
17. nelemente 1 bersicht der Bedienelemente 1 Mikrofonkapsel 2 Anzeige des Batteriestatus 3 Anzeige der Sendefrequenz oder der Sende gruppe und des bertragungskanals Abb 4 Nach dem Einschalten des Mikrofons und beim Bet tigen der Tasten 4 6 leuchtet die Display Hintergrundbeleuchtung auf Sie erlischt automa tisch ca 10 s nach dem letzten Tastendruck 4 Taste V zur Abwartssuche f r Sendegruppe Kanal im Gruppen Kanaleinstellmodus zum Verringern der Frequenz im Frequenzeinstell modus bzw der Empfindlichkeit im Empfindlich keitseinstellmodus und zum Deaktivieren der Sperrfunktion im Sperreinstellmodus 5 Taste A zur Aufw rtssuche f r Sendegruppe Kanal im Gruppen Kanaleinstellmodus zum Erh hen der Frequenz im Frequenzeinstell modus bzw der Empfindlichkeit im Empfindlich keitseinstellmodus und zum Aktivieren der Sperr funktion im Sperreinstellmodus 6 Taste SET bei nicht gesperrtem Mikrofon zum Aufrufen und Verlassen der Einstellmodi f r Sendegruppe Kanal Frequenz Empfindlichkeit Sperrfunktion Kap 5 1 5 2 5 3 und 5 4 1 bei gesperrtem Mikrofon zum Aufrufen und Verlassen des Einstellmodus f r die Sperrfunktion Kap 5 4 2 7 Kappe f r das Batteriefach zum Einsetzen oder Wechseln der Batterien 2 x 1 5 V Mignon Batte rie die Kappe abschrauben 8 Kennzeichnungsring l sst sich gegen einen der beiliegenden Farbringe austauschen 9 Ein Ausschalter 10 Sicherungskappe
18. on without delay 12 4 pole contact each on the microphone cartridge fig 2 and on the handle fig 3 prior to assembling the microphone cartridge and the handle fit the contacts into each other JTS ENGLISH ENGLISH 8 The identification ring 8 can be exchanged against one of the coloured rings supplied This allows colour coding of several systems with dif ferent radio frequencies 9 To switch off the microphone after operation setthe POWER switch 9 to OFF 5 1 Adjusting the transmission group and the transmission channel 1 Keep the key SET 6 pressed for 2 s until either the indication MHz or the group indication A b L or d starts flashing on the display If the indication MHz starts flashing shortly actuate the key SET once again to go to the group adjusting mode Note To exit the adjusting mode without making an adjustment press the key SET so many times until the display shows LAnLEL The microphone will then return to normal operation Use the cursor keys to adjust the transmission group With the key V 4 the groups will be scanned in descending order with the key A 5 they will be scanned in ascending order The corresponding channels and transmission frequencies can be found in the table in fig 4 3 Press the key SET again to call the channel ad justing mode On the display the channel indication 1 16 will start flashing Use the cursor keys to adjust the transmission
19. te V 4 werden die Gruppen absteigend durchlaufen mit der Taste A 5 aufsteigend Die zugeh rigen Kan le und Sendefrequenzen sind in der Tabelle Abb 4 angegeben Durch erneutes Dr cken der Taste SET den Kanaleinstellmodus aufrufen Im Display blinkt die Kanalanzeige 1 16 2 4 Mit den Pfeiltasten den bertragungskanal einstel len mit der Taste V werden die Kan le absteigend durchlaufen mit der Taste A aufsteigend 5 Die Einstellung durch Dr cken der Taste SET spei chern Im Display erscheint kurz Stor der Ein stellmodus wird verlassen und das Mikrofon wech selt auf den Normalbetrieb ajeje 790 87 790 750 791 125 790 625 791 125 791 875 798 625 A 875 625 250 625 705 875 707 125 707 575 799 125 800 575 801 375 805 750 8 8 625 125 000 802 875 803 375 804 125 806 250 807 625 813 625 813 750 813 750 Abb 4 Sendefrequenzen in MHz der Gruppen und Kan le E MONACOR INTERNATIONAL gung im Internet auf der Homepage der Bundesnetz agentur www bundesnetzagentur de Da f r Funksysteme die in diesem Frequenzbe reich arbeiten in anderen L ndern eventuell andere gesetzliche Bestimmungen gelten informieren Sie sich vor der Inbetriebnahme des Systems au erhalb Deutschlands bitte bei der MONACOR Niederlassung oder der entsprechenden Beh rde des Landes 4 Stromversorgung e Setzen Sie nur Batterien des gleichen Typs ein und tauschen Sie die Bat
20. terien immer komplett aus e Nehmen Sie bei l ngerem Nichtgebrauch z B l n ger als eine Woche die Batterien heraus So bleibt das Mikrofon bei einem eventuellen Auslaufen der Batterien unbesch digt 1 Die Kappe 7 f r das Batteriefach abschrauben 2 Zwei 1 5 V Batterien der Gr e Mignon R6 AA mit den Plus und Minuspolen wie auf dem Halter aufgedruckt einsetzen 3 Die Batteriefachkappe gerade an das Gewinde des Mikrofonk rpers ansetzen und festschrauben 5 Inbetriebnahme 1 Das Mikrofon noch ausgeschaltet lassen Zuerst den Empf nger auf einen st rungsfreien bertra gungskanal einstellen siehe Bedienungsanleitung des Empf ngers 2 Danach das Mikrofon einschalten Den Ein Aus schalter 9 unten am Mikrofon in die Position POWER stellen Gegebenenfalls vorher die Sicher ungskappe 10 nach unten schieben Im Display 3 erscheint die eingestellte Sendegruppe mit ent sprechendem bertragungskanal im Gruppen modus z B H iH oder die Sendefrequenz im Frequenzmodus sowie ein Batteriesymbol 2 das den aktuellen Ladezustand der Batterien in mehre ren Stufen anzeigt gt Mn I 7 _ voll ersch pft Sind die Batterien verbraucht Anzeige gt wech selt zus tzlich zur Warnung am Empf nger die Dis playfarbe von Gr n auf Orange Die leicht versenkten Tasten 4 6 lassen sich ohne weitere Hilfsmittel mit der Daumenspitze ein fach bet tigen 4 Das Mikrofon auf die gle
21. uenz einstellen bei jedem Dr cken der Taste V 4 verringert sie sich um 25kHz bei jedem Dr cken der Taste 5 erh ht sie sich um 25 kHz Zum Durchlaufen eines gro en Frequenzbereiches die entsprechende Taste gedr ckt halten Hinweis Bei gleichzeitiger Verwendung mehrerer Funksysteme sollten die Funkfrequenzen der einzelnen Systeme sorgf ltig aufeinander abge stimmt werden um St rungen zu vermeiden Frequenzbeispiele f r den gleichzeitigen Betrieb mehrerer Systeme finden Sie im Internet auf www jts germany de unter Informationen Inter modulationsfreies Frequenzsetup 3 Die Einstellung durch Dr cken der Taste SET spei chern Im Display erscheint kurz 5tort der Ein stellmodus wird verlassen und das Mikrofon wech selt auf den Normalbetrieb 5 3 Einstellen der Empfindlichkeit 1 Die Taste SET 6 2s gedr ckt halten danach die Taste SET noch dreimal kurz dr cken sodass das Display die aktuelle Empfindlichkeit anzeigt 0 dB 6dB 12 dB oder 24 dB Hinweis Um den Einstellmodus ohne eine Einstel lung zu verlassen die Taste SET so oft dr cken bis im Display L nLEL erscheint Das Mikrofon schaltet danach auf normalen Betrieb zur ck Die Empfindlichkeit nach der Anzeige AF im Display des Empf ngers so einstellen dass ein optimaler Lautst rkepegel des Mikrofons erreicht wird Bei zu hoher Lautst rke verzerrt das Mikrofon dann mit der Taste V 4 einen niedrigeren Wert einstellen Bei zu geringer L

Download Pdf Manuals

image

Related Search

Related Contents

FA - 中川電気工業  特許権・実用新案権・意匠権関連..................................................  off!® active chase-moustiques en vaporisateur  *DIGITAL IN/OUT THERMOMETER WITH DIGITAL  カラースノコ(エンボス付) 取扱説明書  BILECO®  

Copyright © All rights reserved.
Failed to retrieve file