1. 1 1 LCD display A 2 Rotary Selector to Select additional 2 functions and to turn the Power On or Off 3 Push button to Select additional 3 functions and to switch the Power On or Off 4 Input for all functions or otherwise ere BH 4 specified Red test lead for positive E T E polarity and Black test lead for Ground reference 2 Safety Terms in this manual WARNING identifies conditions and actions that could result in serious injury or even death to the user CAUTION identifies conditions and actions that could cause damage or malfunction in the instrument This manual contains information and warnings that must be followed for operating the instrument safely and maintaining the instrument in a safe operating condition If the instrument is used in a manner not specified by the manufacturer the protection provided by the instrument may be impaired The meter is intended only for indoor use The meter is protected against the users by double insulation per EN61010 1 IEC61010 1 CSA C22 2 No 1010 1 92 and UL61010B 1 to CAT IIl 300V amp CAT Il 600V MD 9010 General Purpose Auto Check Digital Multimeter Safety Cenelec Directives Measurement Category Ill CAT Ill is for measurements performed in the building installation Examples are measurements on distribution boards circuit breakers wiring including cables bus bars junction boxes switches socket outlets in the fixed installation and equipme
2. All function operations described hereafter are via the Red test lead for positive polarity and Black test lead for Ground reference or otherwise specified WARNING Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to determine proper meter functioning Functiones in Auto V Q position Quick Start MD 9010 AutoCheck mode is the default function in Auto V Q position Press the SELECT button momentarily to select and step through the functions AutoCheck Continuity gt EF gt ACV gt DCV gt 2 gt Hz gt CxAutoCheck AutoCheck mode MD 9010 This innovative AutoCheck feature automatically selects measurement function of DCV ACV or Resistance Q based on the input via the test leads e With no input the meter displays Auto when it is ready e With no voltage signal but a resistance below 6MQ is present the meter displays the resistance value When below 250 is present the meter further gives a continuity beep tone e When a signal above the threshold of DC 1 2V or AC 1 5V up to the rated 600V is present the meter displays the appropriate voltage value in DC or AC whichever larger in peak magnitude e Overload Alert Feature When above rated 600V is present the meter displays OL with a warning beep tone Disconnect the test leads from the signal immediately to avoid hazards Note Range Lock Feature When a measurement reading is
3. MD 9010 4 Eingang f r alle Funktionen soweit nicht anders angegeben Rote Pr fleitung f r Auto Check positive Polarit t und schwarze e o sie 600V CAT II 7 u Digital Multimeter A 92 Pr fleitung f r Bezugsmasse 2 Sicherheit Begriffe in dieser Anleitung WARNUNG Gibt Bedingungen oder Aktionen an die zu schweren Verletzungen oder sogar zum Tod des Anwenders f hren k nnten VORSICHT Gibt Bedingungen oder Aktionen an die Besch digungen oder Fehlfunktionen des Instruments verursachen k nnten Diese Anleitung enth lt Informationen und Warnungen die befolgt werden m ssen um das Instrument sicher zu betreiben und in sicherem Betriebszustand zu erhalten Wenn das Ger t auf eine Weise benutzt wird die nicht vom Hersteller angegeben wurde kann der Schutz den das Ger t bietet beeintr chtigt werden Das Messger t ist nur f r den Gebrauch in Innenr umen bestimmt Das Messger t ist gegen ber dem Anwender durch Schutzisolierung nach EN61010 1 IEC61010 1 CSA C22 2 No 1010 1 92 sowie UL61010B 1 CAT III 300V und CAT II 600V gesch tzt 14 MD 9010 Digitalmultimeter Cenelec richtlinien Messkategorie Ill CAT III gilt f r Messungen an der Geb udeinstallation Beispiele sind Messungen an Verteilertafeln Schaltautomaten Verdrahtung einschlie lich Kabeln Sammelschienen Anschlussk sten Schaltern Steckdosen in der festen Installation sowie Messungen an Einrichtungen f r den industriellen Gebrauch und
4. Q ist ein unabh ngiger Bereich nur bei MD 9010 940 Digits zur spezifizierten Genauigkeit hinzuf gen wenn die Anzeige unter 20 des Bereichs liegt 1 2 Dig I je 6 Dig Frequenz und MD 9010 BEREICH ee O bei 10 00 Hz 30 00 lt 20 V Sinus kHz 2 0 5 leff Hz Sinus eff Empfindlichkeit Sinus eff Frequenz in Position Auto VQ gt 3 V Netzfrequenz in Position V nur MD 9010 bei Bereich 6 000 VAC bei Bereich 60 00 VAC gt 3V gt 6V MD 9010 Digitalmultimeter bei Bereich 600 0 VAC gt 60 V Diodenpr fung MD 9010 Pr fstrom typisch Leerlaufspannung 0 48 mA bei MD lt 1 6 VDC 9010 Gleichstrom uA Bereich nur MD 9010 BEREICH Genauigkeit ER 15 3 2000 uA a 3 e mV uA Wechselstrom uA Bereich nur MD 9010 BEREICH Genauig Spannungsabf keit all 400 0 uA OOS ls mV uA 2000 pA Gi 77 E mV uA Akustische Durchgangspr fung Leerlaufspannung 0 4 VDC typisch H rschwelle MD 9010 zwischen 50 Q und 300 Q Kontaktlose Erfassung elektrischer Drahtlose Erkennung elektrischer Felder EF nur MD 9010 zwischen MD 9010 20 Vund80V_ kt 45 V und 125V ee O OVund2i5V ie M20Vund285V eee 170 V und mehr Ku Anzeige Bargraphsegmente und h rbare Piept ne proportional zur Feldst rke Erfassungsfrequenz 50 60 Hz Erfassungsantenne Obere linke Ecke des Messger ts 23 Technische Daten EF Erfassung mit Sondenkontakt Zur genaueren Anze
5. being displayed in AutoCcheck mode press the SELECT button momentarily 1 time can lock the function range it was in The LCD annunciator Del turns off Range lock can speed up repetitive measurements Press the SELECT button momentarily again to return to AutoCheck mode Hazardous Alert When making resistance measurements in AutoCheck mode an unexpected display of voltage readings alerts you that the part under test is still energized AutoCheck nominal input impedances are slightly lower than that of common digital multimeters They are in fact more similar to that of most traditional analog multimeters LoZ will display on the LCD to remind the users in such cases Although not likely if such impedance might damage your circuits use the common impedance Hi Z voltage mode for making voltage measurements on them Continuity Audible with Symbolic Display From AutoCheck with Auto being displayed press the SELECT button momentarily 1 time to select Continuity function The meter displays a symbolic open switch display Sch a a when it is ready Continuity is convenient for checking wiring connections and operation of switches A continuous beep tone with a symbolic closed switch display MD 9010 General Purpose Auto Check Digital Multimeter Operation aaaa indicates a complete circuit In noisy environments it is helpful to see continuity measurements Electric Field EF Detection
6. einigen anderen Ger ten zum Beispiel station ren Motoren mit dauernder Verbindung zur festen Installation Messkategorie Il CAT II gilt f r Messungen an Stromkreisen die direkt mit der Niederspannungsinstallation verbunden sind Beispiele sind Messungen an Haushaltsger ten Handwerkzeugen und hnlichen Ger ten WARNUNG Um die Feuer oder Stromschlaggefahr zu reduzieren setzen Sie dieses Produkt nicht Regen oder Feuchtigkeit aus Um Stromschlaggefahr zu vermeiden beachten Sie die geeigneten Sicherheitsma nahmen bei Arbeiten an Spannungen ber 60 VDC oder 30 Ver Diese Spannungspegel stellen eine m gliche Stromschlaggefahr f r den Anwender dar Ber hren Sie die Messspitzen oder den zu pr fenden Kreis nicht w hrend er unter Spannung steht Halten Sie Ihre Finger bei der Messung hinter den Fingerschutzschilden an den Pr fleitungen Untersuchen Sie vor der Verwendung des Instruments die Pr fleitungen und Sonden auf besch digte Isolierung oder frei liegendes Metall Wenn Sie Defekte finden wechseln Sie die Teile sofort aus INTERNATIONALE ELEKTROSYMBOLE Vorsicht Siehe Erkl rungen in dieser Anleitung Vorsicht Es besteht die Gefahr eines Stromschlags Erde Erdung Doppelisolierung oder Schutzisolierung Sicherung AC Wechselstrom DC Gleichstrom att 3 Cenelec richtlinien Das Instrument entspricht der CENELEC Niederspannungsrichtlinie 73 23 EWG und der Richtlinie Elektromagnetische Vertr glichkeit 89 33
7. sich intelligent nach etwa 3 Minuten mit leerer Messwertanzeige und ohne Tasten Schalterbet tigung ab Funktionen HOLDW und 18 MD 9010 Digitalmultimeter Betrieb Automatische Bereichswahl Wenn die gew hlte Funktion mehr als einen Bereich hat stellt sich das Messger t automatisch auf den optimalen Bereich und die optimale Aufl sung ein Es ist keine manuelle Bereichswahl erforderlich 19 MD 9010 Digitalmultimeter Wartung 5 Wartung WARNUNG Um einen Stromschlag zu vermeiden trennen Sie vor dem Offnen des Geh uses die Pr fleitungen von spannungsf hrenden Stromkreisen Betreiben Sie das Ger t nicht mit offenem Geh use Reinigung und Lagerung Wischen Sie das Geh use regelm ig mit einem feuchten Tuch und einem milden Reinigungsmittel ab verwenden Sie keine Scheuermittel oder L sungsmittel Wenn das Messger t l nger als 60 Tage nicht benutzt werden soll entfernen Sie die Batterie und lagern Sie sie getrennt St rungssuche Wenn das Instrument nicht funktioniert berpr fen Sie Batterie Leitungen usw und ersetzen Sie sie bei Bedarf berpr fen Sie wiederholt die Bedienung wie sie in dieser Bedienungsanleitung beschrieben ist Wenn der Spannungs Widerstandseingang des Instruments versehentlich oder durch anomale Betriebsbedingungen hohen Spannungsspitzen ausgesetzt wurde die meist durch Blitzschlag oder Schalt berspannungen in Ihrem System verursacht werden brennen die Serien Sicherungswiderst nde wie S
8. weist auf eine offene defekte Diode hin Kehren Sie die Anschl sse der Pr fleitungen ber der Diode um Das Digitaldisplay zeigt OL wenn die Diode gut ist Jede andere Anzeige weist darauf hin dass die Diode einen endlichen Widerstand hat oder kurzgeschlossen ist defekt ist Kurzes Dr cken der SELECT Taste w hlt den niedrigsten den 600 Q Bereich f r Messungen niedrigerer Widerst nde Er ist ein erweiterter Bereich um die AutoCheck Widerstandsfunktion Q zu erg nzen Mikroamperefunktionen uA f r Gleichstrom und Wechselstrom nur MD 9010 Bringen Sie den Drehschalter in die Position uA Die Anzeige auf dem Display erfolgt in uA obwohl keine Einheitenanzeige auf dem Display erscheint Die Grundfunktion ist Gleichstrom uA Es gibt keine symbolische Anzeige f r Gleichstrom Dr cken Sie kurz die Taste SELECT um Wechselstrom uA zu w hlen Das Wechselspannungs LCD Feld ko geht an Diese Bereiche sind wie andere Funktionen bis zur maximalen Nennspannung des Messger ts gesch tzt Andere Funktionen Ein und Ausschalten Dr cken Sie bei den Modellen MD 9010 die Taste SELECT halten Sie sie eine Sekunde lang und lassen Sie sie wieder los um das Ger t EIN oder AUSzuschalten Dr cken und halten Sie die Taste SELECT etwa 6 Sekunden lang um das System mit einem Gesamt Reset in den Grundzustand zur ckzusetzen falls das Messger t unerwartet h ngen bleibt Automatische Abschaltung Die Modelle MD 9010 schalten
9. 6 EWG 15 MD 9010 Digitalmultimeter Betrieb 4 Betrieb Anmerkung Alle nachstehend beschriebenen Funktionsbedienungen verwenden die rote Pr fleitung f r positive Polarit t und die schwarze Pr fleitung f r die Bezugsmasse soweit nicht anders angegeben WARNUNG Pr fen Sie vor und nach Messungen an gef hrlichen Spannungen die Spannungsfunktion an einer bekannten Quelle wie etwa der Netzspannung um die einwandfreie Funktion des Messger tes zu berpr fen Funktionen in der Position Auto V nur MD 9010 Schnellstart nur MD 9010 Die Betriebsart AutoCheck ist die voreingestellte Funktion in der Position Auto V Q Dr cken Sie kurz die Taste SELECT um die Funktionen zu w hlen und zu durchlaufen AutoCheck Durchgang gt EF gt ACV gt DCV gt 2 gt HzZ gt CxAutoCheck AutoCheck Modus nur MD 9010 Diese innovative Funktion AutoCheck w hlt automatisch anhand des ber die Pr fleitungen anliegenden Eingangssignals die Messfunktion Gleichspannung Wechselspannung oder Widerstand Q e Bei fehlendem Eingangssignal zeigt das Messger t Auto an wenn es bereit ist e Wenn kein Spannungssignal aber ein Widerstand unter 6 MQ vorhanden ist zeigt das Messger t den Widerstandswert an Unter 25 Q gibt das Messger t nur MD 9010 au erdem einen Durchgangs Piepton ab e Wenn ein Signal oberhalb einer Schwelle von 1 2 VDC oder 1 5 VAC bis zur Nennspannung 600 V anliegt zeigt das Messger t d
10. AC rm Other Functions DCV ACV amp Line Level Hz functions Rotate the rotary selector to the V position selects common impedance Hi Z voltage measurements DCV is the default function Press SELECT button momentarily to select ACV The AC annunciator V turns on Press momentarily again to activate the Line Level Hz function Note Line Level Hz input sensitivity varies automatically with ACV range selected when Line Level Hz is selected AC 6V range has the highest and AC 600V range has the lowest sensitivity Measuring the signal in ACV function WHILE selecting Line Level Hz function in that ACV range automatically sets the most appropriate sensitivity for higher voltage applications This can avoid electrical noises as in 110 220V line voltage applications for example If the reading shows zero due to insufficient signal levels select Line Level Hz function BEFORE making measurements at AC 6V range will set the highest sensitivity MD 9010 General Purpose Auto Check Digital Multimeter Operation Diode amp 6000 functions Rotate the rotary selector to the bk 6000 position Diode test is the default function The reading shows the approximate voltage drop across the test leads Normal forward voltage drop forward biased for a good silicon diode is between 0 400V to 0 900V A reading higher than that indicates a leaky diode defective A zero reading indicates a shorted diode defective and the meter will give a
11. From AutoCheck with Auto being displayed press the SELECT button momentarily 2 times to select EF Detection feature The meter displays EF when it is ready Signal strength is indicated as a series of bar graph segments on the display and variable beep tones Non Contact EF Detection An antenna is located at the top left corner of the meter which detects electric field surrounds current carrying conductors It is ideal for tracing live wiring connections locating wiring breakage and to distinguish between live or earth connections Probe Contact EF Detection For more precise indication of live wires such as distinguishing between live and ground sockets use the Red test probe for direct contact measurements V and Q of AutoCheck In Manual Selection From AutoCheck with Auto being displayed press the SELECT button momentarily 3 times to select ACV 4 times to select DCV and 5 times to select Resistance Q functions of AutoCheck Such selected function remains auto ranging Frequency And Capacitance From AutoCheck with Auto being displayed press the SELECT button momentarily 6 times to select Frequency Hz 7 times to select Capacitance F functions and 8 times to return to AutoCheck mode Note Unlike the Line Level Hz Frequency function as stated this Common Hz Frequency function is set only at the highest input sensitivity mainly for measuring small electronic signals of below 20V
12. METREL MD 9010 General Purpose Auto Check Digital Multimeter SR METREL MD9010 Auto Check GES Niottel Mishtimeter A BEY CAT ih MD 9010 User Manual Bedienungsanleitung Version 1 0 Code no 20 751 285 ZS METREL Distributor METREL d d Ljubljanska cesta 77 1354 Horjul Slovenia e mail metrel metrel si web site http www metrel si Metrel GmbH Mess und Pr ftechnik Orchideenstrasse 24 90542 Eckental Brand Germany E mail metrel metrel de Internet http www metrel de Metrel UK Test amp Measurement Unit 1 Hopton House Ripley Drive Normanton Industrial Estate Normanton West Yorkshire WF6 1QT Great Britain E mail info metrel co uk Internet http www metrel co uk 2007 METREL No part of this publication may be reproduced or utilized in any form or by any means without permission in writing from METREL MD 9010 General Purpose Auto Check Digital Multimeter Table of contents Inhalt Table of contents Inhalt English E ee tee lee wre ee ee ee nee ne nee 4 2 DAC ea serien 4 GONE Rer 5 Ai CK AU OM espera seen ce as een Terror Terre 6 SE Welte ue 9 SCI AO IA Eee ne 10 LIMITED WARRANTY E 13 Deutsch T Ge e E ane e lee tal WE 14 2 SIC TIS e EE 14 SCENE ee ere EE 15 NEE een 16 SAN NUNO EE 20 B LECHNISCHE DAEN Eed 21 EINGESCHR NKTE GARANTIE 24 MD 9010 General Purpose Auto Check Digital Multimeter Product Description Safety 27F01 1 Product Description
13. chmelzsicherungen durch nehmen eine hohe Impedanz an um den Anwender und das Instrument zu sch tzen Die meisten Messfunktionen ber diesen Eingang sind dann unterbrochen Die Serien Sicherungswiderst nde und die Funkenstrecken sollten dann durch einen qualifizierten Techniker ausgetauscht werden Im Abschnitt EINGESCHRANKTE GARANTIE erfahren Sie wie Sie Garantie oder Reparatur Kundendienst erhalten Batteriewechsel Wenn das Messger t beim Hochfahren st ndig die Anzeige zur cksetzt oder die Anzeige f r schwache Batterie El erscheint ersetzen Sie die Batterie so schnell wie m glich Das Messger t verwendet eine 3 V Knopfzelle IEC CR2032 Achten Sie vor dem Offnen der Geh useunterseite darauf dass das Messger t abgeschaltet ist um einen abrupten Reset ber die Versorgung an einem laufenden Messgeratesystem zu vermeiden Trennen Sie die Prufleitungen von spannungsf hrenden Stromkreisen L sen Sie die Schrauben an der Gehauseunterseite Heben Sie das Ende des Gehauseunterteils nahe den Pr fleitungseing ngen an bis es sich vom Gehauseoberteil l st Ersetzen Sie die Batterie Beachten Sie die Batteriepolarit ten die positive Seite muss nach oben zeigen zur Geh useunterseite Setzen Sie das Geh useunterteil wieder ein achten Sie darauf dass die Einschnappstelle am Oberteil nahe der LCD Seite einrastet Befestigen Sie die Schrauben wieder Anmerkung zum Batteriewechsel bei MD 9010 MD 9010 benutzen zum Betreiben de
14. counts Updates 5 per second nominal 0 C 40 C Maximum relative humidity 80 for temperature up to 31 C decreasing linearly to 50 relative humidity at 40 C Operating below 2000m 20 C 60 C lt 80 R H with battery removed Nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Average sensing 2 Meets IEC61010 1 UL61010B 1 CAN CSA C22 2 No 1010 1 92 4kV lightning surge 1 2 50us CAT II 600V and CAT III 300V Meets EN61326 1997 1998 A1 EN61000 4 2 1995 amp EN61000 4 3 1996 e InanRF Field of 3V m e Capacitance function is not specified e Other function ranges e Total accuracy Specified accuracy 45d e Performance above 3V m is not specified 600VDC amp VAC rms Below approx 2 4V 3V standard button battery x 1 IEC CR2032 ANSI NEDA 5004LC 6mA for Voltage functions on Auto VQ position and 2mA for other functions 2 2uA Idle for 3 minutes L113mm x W53mm x H10 2mm Approx 78 gm AutoCheck Automatic V amp Q Selection and EF Detection Battery installed and User s manual Accuracy is given as of reading digits number of digits or otherwise specified 23 C 5 C and less than 75 R H 10 MD 9010 General Purpose Auto Check Digitalmultimeter Specification DC Voltage MD 9010 MD 9010 Updates gt 1 minute RANGE Accuracy on large values Specified with battery voltage above 2 8V half full battery Accuracy decr
15. die Netzfrequenzfunktion Hz zu aktivieren 17 MD 9010 Digitalmultimeter Betrieb Anmerkung Bei Auswahl der Netzfrequenzfunktion Hz ndert sich die Empfindlichkeit des Netzfrequenzeingangs automatisch mit dem gew hlten Wechselspannungsbereich Der Wechselspannungsbereich 6 V hat die h chste der Bereich 600 V die niedrigste Empfindlichkeit Die Messung des Signals in der Wechselspannungsfunktion W HREND der Anwahl der Netzfrequenzfunktion in diesem Wechselspannungsbereich stellt automatisch die geeignetste Empfindlichkeit fur Anwendungen bei h heren Spannungen ein Damit k nnen elektrische St rungen wie z B bel Netzspannungsanwendungen mit 110 220 V vermieden werden Wenn wegen ungenugender Signalpegel Null angezeigt wird w hlen Sie die Netzfrequenzfunktion VOR der Durchf hrung von Messungen im Wechselspannungsbereich 6 V damit wird die h chste Empfindlichkeit eingestellt Funktionen Diode und 600 Q nur MD 9010 Bringen Sie den Drehschalter in die Position PF 6000 Die Grundfunktion ist die Diodenpr fung Die Anzeige gibt den entsprechenden Spannungsabfall ber den Prufleitungen an Der normale Spannungsabfall in Durchlassrichtung liegt bei einer guten Siliziumdiode zwischen 0 400 V und 0 900 V Eine h here Anzeige weist auf eine lecke defekte Diode hin Eine Anzeige von Null gibt eine kurzgeschlossene defekte Diode an und das Messger t gibt einen langen Piepton als Durchgangswarnung ab OL
16. e to the best range and resolution No manual ranging is required MD 9010 General Purpose Auto Check Digitalmultimeter Maintenance 5 Maintenance WARNING To avoid electrical shock disconnect test leads from live circuits before opening the case Do not operate with open case Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for periods of longer than 60 days remove the battery and store it separately Trouble Shooting lf the instrument fails to operate check battery leads etc and replace as necessary Double check operating procedure as described in this user s manual lf the instrument voltage resistance input has subjected to high voltage transient mostly caused by lightning or switching surge to your system by accident or abnormal conditions of operation the series fusible resistors will be blown off become high impedance like fuses to protect the user and the instrument Most measuring functions through this input will then be open circuit The series fusible resistors and the spark gaps should then be replaced by qualified technician Refer to the LIMITED WARRANTY section for obtaining warranty or repairing service Battery replacement lf the meter starts up with persistent resetting display or with low battery icon E turns on replace the battery ASAP The meter uses one 3V coin battery IEC CR2032 Before opening t
17. eases gradually to 12 at low battery warning voltage of approx 2 4V Input Impedance AutoCheck Lo Z DCV 833kQ 4 2kQ Ohms MD 9010 when displaying Auto 90pF nominal ia na aa ce NMRR gt 30dB 50Hz 60Hz CMRR gt 100dB DC 50Hz 60Hz Rs 1kQ e DCV AutoCheck Threshold Open Circuit Voltage 0 4VDC typical ug BEE 2 Sc lk lie AutoCheck is for 6 000kQ 6 000MQ a a ranges 600 0Q is an independent range MD 9010 Hi Z DCV only for MD 9010 only Add 40d to specified accuracy while reading is below 20 of range AC Voltage MD 9010 Hz Frequency MD 9010 6 000V 60 00V 1 5 5d ame fa Specified at 450 0V 600 0V cy CMRR gt 60dB DC to 60Hz 10 00Hz lt 20V Sine Rs 1kQ 30 00kHz 1 0 un rms MD 9010 Input Impedance 10 00HZ lt 600V Sine AutoCheckTM Lo Z ACV 833kQ 999 9Hz rms 4 2kQ when displaying Auto SM Sine rms 90pF nominal Hz i in Auto VQ position gt 3V Hi Z ACV 5MQ 90pF nominal Line level Hz in V position MD 9010 ACV AutoCheck Threshold only 6 000VAC range gt 3V gt 1 5VAC 50 60Hz nominal 60 00VAC range Oy Range for MD 9010 only 600 0VAC range gt 60V Capacitance MD 9010 Diode Tester MD 9010 RANGE Current Open Circuit Voltage 100 0nF 1000nF 0 48mA for MD lt 1 6VDC 9010 10 00uF 100 0uF 3 5 6d 2000uF Accuracy below 50nF is not specified DC uA Current MD 9010 Accu
18. eb Durchgangsmessung akustisch mit symbolischer Anzeige nur MD 9010 Vom AutoCheck Modus aus Anzeige Auto dr cken Sie einmal kurz die Taste SELECT um die Funktion Durchgangspr fung zu w hlen Das Messger t zeigt das Symbol eines offenen Schalters an wenn es bereit ist Die Durchgangspr fung ist zum Pr fen von Verdrahtungsverbindungen und der Funktion von Schaltern geeignet Ein Dauer Piepton mit Anzeige des Symbols eines geschlossenen Schalters gibt einen geschlossenen Stromkreis an In lauten Umgebungen ist es hilfreich die Durchgangsmessung zu sehen Erkennung elektrischer Felder EF nur MD 9010 Vom AutoCheck Modus aus mit der Anzeige Auto dr cken Sie zweimal kurz die Taste SELECT um die Funktion EF Erfassung elektrischer Felder zu w hlen Das Messger t zeigt EF an wenn es bereit ist Die Signalst rke als eine Reihe von Bargraph Segmenten auf dem Display und als variable Piept ne angezeigt e Kontaktlose EF Erfassung In der oberen linken Ecke des Messger ts befindet sich eine Antenne die elektrische Felder erfasst wie sie stromf hrende Leiter umgeben Dies ist ideal zum Verfolgen von stromf hrenden Verdrahtungsverbindungen zum Orten von Drahtbr chen und zum Unterscheiden zwischen stromf hrenden und Erdungsverbindungen e EF Erfassung mit Sondenkontakt Zur genaueren Anzeige von stromf hrenden Dr hten wie etwa zur Unterscheidung zwischen stromf hr
19. en entsprechenden Spannungswert als Gleich oder Wechselspannung an je nachdem welcher Spitzenwert gr er ist e Funktion berlastalarm Wenn eine h here als die Nennspannung von 600 V anliegt zeigt das Messger t OL an zusammen mit einem Warn Piepton Trennen Sie die Pr fleitungen sofort vom Signal um Gefahren zu vermeiden Anmerkung Bereichsarretierung Wenn im AutoCheck Modus ein Messwert angezeigt wird friert einmaliges kurzes Dr cken der Taste SELECT den Funktionsbereich ein in dem sich das Ger t befand Das LCD Feld UIWER geht aus Die Bereichsarretierung kann wiederholte Messungen beschleunigen Zur R ckkehr zum AutoCheck Modus dr cken Sie die Taste SELECT erneut kurz Gefahrenalarm Beim Durchf hren von Widerstandsmessungen im AutoCheck Modus alarmiert Sie die unerwartete Anzeige von Spannungswerten daruber dass der Prufling noch unter Spannung steht Die Nenn Eingangsimpedanzen im AutoCheck Modus sind etwas niedriger als die blicher Digitalmultimeter Sie liegen eher n her bei denen herk mmlicher analoger Multimeter In solchen F llen erscheint LoZ niedrige Impedanz auf der LCD Anzeige um die Anwender daran zu erinnern Wenn diese Impedanz ihren Stromkreis besch digen k nnte obwohl das nicht wahrscheinlich ist verwenden Sie den Spannungsmodus mit blicher Impedanz Hi Z nur MD 9010 um darin Spannungsmessungen auszuf hren 16 MD 9010 Digitalmultimeter Betri
20. enden und Erdungsbuchsen verwenden Sie die rote Pr fleitung f r Messungen im direkten Kontakt V und O von AutoCheck in manueller Auswahl nur MD 9010 Vom AutoCheck Modus aus mit der Anzeige Auto dr cken Sie dreimal kurz die Taste SELECT um die Funktion Wechselspannung zu w hlen viermal um Gleichspannung zu w hlen und f nfmal um die Widerstandsfunktion Q von AutoCheck zu w hlen Die auf diese Weise gew hlte Funktion verbleibt in der automatischen Bereichswahl Frequenz und Kapazit t nur MD 9010 Vom AutoCheck Modus aus mit der Anzeige Auto dr cken Sie sechsmal kurz die Taste SELECT um die Funktion Frequenz Hz zu w hlen siebenmal um Kapazit t F zu w hlen und achtmal um zu AutoCheck zur ckzukehren Anmerkung Anders als die angegebene Funktion Netzfrequenz nur beim MD 9010 wird diese allgemeine Frequenzfunktion nur bei der h chsten Eingangsempfindlichkeit eingestellt haupts chlich zum Messen kleiner elektronischer Signale unter 20 Ver Andere Funktionen Gleichspannungs Wechselspannungs und Netzfrequenzfunktionen nur MD 9010 Durch eine Drehung des Drehschalters in die Stellung V wird die Spannungsmessung mit blicher Impedanz Hi Z gew hlt Die Grundfunktion ist Gleichspannungsmessung Dr cken Sie kurz die Taste SELECT um Wechselspannung zu w hlen Das Wechselspannungs LCD Feld V geht an Dr cken Sie erneut kurz um
21. er Sand oder Steine e Sch den durch Nichtbeachtung der Gebrauchsanleitung z B Anschluss an eine falsche Netzspannung oder Stromart oder Nichtbeachtung der Aufbauanleitung Gew hnlicher normaler Verschlei Verbrauch e und alle anderen von au en auf das Ger t einwirkenden Ereignisse die nicht auf den gew hnlichen Gebrauch Nutzung zur ckzuf hren sind Verschlei Verbrauchsmaterialien wie z B Trageriemen Kunststoffteile e Zubeh r Sicherungen Sicherungswiderstande Funkenstrecken Batterien oder jedes Produkt das nach Meinung von METREL missbr uchlich verwendet ver ndert vernachl ssigt oder versehentlich oder durch abnorme Betriebsbedingungen oder Behandlung besch digt worden ist DIESE GARANTIE GILT AUSSCHLIESSLICH UND TRITT AN DIE STELLE ALLER ANDEREN AUSDR CKLICHEN ODER STILLSCHWEIGENDEN GARANTIEN EINSCHLIESSLICH ABER NICHT BESCHR NKT AUF ALLE M NGEL ODER GEBRAUCHSTAUGLICHKEITSGARANTIEN F R EINEN BESONDEREN ZWECK ODER GEBRAUCH METREL IST NICHT HAFTBAR F R ALLE BESONDEREN INDIREKTEN NEBEN ODER FOLGESCH DEN NY WC GEDRUCKT AUF RECYCLINGPAPIER BITTE WIEDERVERWERTEN 24
22. he case bottom make sure the meter is switched off to avoid abrupt power reset to a running meter system Disconnect test leads from live circuits Loosen the screw from the case bottom Lift the end of the case bottom nearest the input test leads until it unsnaps from the case top Replace the battery Observe battery polarities with positive faces up towards the case bottom Replace the case bottom and ensure that the snap on the case top near the LCD side is engaged Re fasten the screw Note MD 9010 use micro controller like a computer to run the meter system WHEN THE METER IS POWER ON intermittence battery power failure fast intermittence battery contact interval in the order of millisecond may cause the meter reset re startup abnormally Simply press and hold the SELECT button for approximately 6 seconds to master reset the system if such a situation occurs MD 9010 General Purpose Auto Check Digitalmultimeter Specification 6 Specification GENERAL SPECIFICATIONS Display amp Update Rate Operating Temperature Relative Humidity Altitude Storage Temperature Temperature Coefficient Sensing Pollution Degree Safety Transient Protection Measurement Category E M C Overload Protection Low Battery Power Supply Power Consumption typical APO Consumption typical APO Timing Dimension Weight Special Features Accessories Electrical Specification 3 5 6 digits 6000
23. ice contact your supplier or send the product with proof of purchase and description of the difficulty postage and insurance prepaid to METREL UK Unit 1 Hopton House Ripley Drive Normanton West Yorkshire WF6 1QT METREL assumes no risk for damage in transit METREL will at its option repair or replace the defective product free of charge However if METREL determines that the failure was caused by misused altered neglected or damaged by accident or abnormal conditions of operation or handling you will be billed for the repair The cost of logistics shall be carried by the owner of the products THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE METREL WILL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES KY ES PRINTED ON RECYCLABLE PAPER PLEASE RECYCLE 13 MD 9010 Digitalmultimeter Produktbeschreibung Sicherheit 1 Produktbeschreibung Anmerkung Das Spitzenmodell der Reihe wird stellvertretend f r Illustrationszwecke verwendet Bitte schauen Sie bei Ihrem eigenen Modell welche Funktionen zur Verf gung stehen MIO SES 1 LCD Display AO HU on 2 Drehschalter zum W hlen zus tzlicher Funktionen nur MD 9010 und zum Ein oder Ausschalten 3 Taste zum W hlen zus tzlicher Funktionen alle Modelle und zum Ein oder Ausschalten nur
24. ige von stromf hrenden Dr hten verwenden Sie die rote Sonde f r Messungen im direkten Kontakt MD 9010 Digitalmultimeter Eingeschr nkte garantie EINGESCHR NKTE GARANTIE Bei sorgf ltiger Behandlung und Beachtung der Bedienungsanleitung gew hrleistet der Hersteller Metrel 2 Jahre Garantie ab Kaufdatum Wir verpflichten uns das Ger t kostenlos instand zu setzen soweit es sich um Material oder Konstruktionsfehler handelt Instandsetzungen d rfen nur ausschlie lich von autorisierten Metrel Service Stationen mit freigegeben Reparaturauftrag durchgef hrt werden Weitere Anspr che sind ausgeschlossen Sch den die sich aus der unsachgem en Benutzung des Ger tes ergeben werden nicht ersetzt Innerhalb der ersten 2 Jahre ab Kaufdatum beseitigen wir die als berechtigt anerkannten M ngel ohne Abrechnung der entstandenen Nebenkosten Die Kosten bernahme ist vorher zu kl ren Die Einsendung des Ger tes muss in jedem Fall unter Beif gung des Kaufbeleges erfolgen Ohne Nachweis des Kaufdatums erfolgt eine Kostenanrechung ohne R ckfrage Die R cksendung erfolgt dann per Nachnahme Kaufbeleg bitte unbedingt Aufbewahren Kaufbeleg ist gleich Garantieschein Von der Gew hrleistung Garantie ausgeschlossen sind e Unsachgem er Gebrauch wie z B berlastung des Ger tes oder Verwendung von nicht zugelassenen Zubeh r e Gewaltanwendung Besch digung durch Fremdeinwirkungen oder durch Fremdk rper z B Wass
25. long beep as continuity warning An OL indicates an open diode defective Reverse the test leads connections reverse biased across the diode The digital display shows OL if the diode is good Any other readings indicate the diode is resistive or shorted defective Press SELECT button momentarily selects the lowest 6000 range for lower resistance measurements It is an extended range to complement the AutoCheck Resistance Q function DC uA amp AC uA Micro Amp functions Rotate the rotary selector to the uA position The display reading unit is in uA although there is no unit annunciator on the display DC uA is the default function There is no annunciator for DC Press SELECT button momentarily to select AC uA The AC annunciator V turns on These ranges like other functions are protected up to the maximum rated voltages of the meter Other Features Power On amp Off Press and hold the SELECT button for 1 second and then release to turn the power ON or OFF Press and hold the SELECT button for approximately 6 seconds to master reset the system to the default stage if in case the meter hangs up unexpectedly Auto Power Off Turn off intelligently after approximately 3 minutes of idle measurement readings and no button switch activities Model turns off automatically after approximately 30 minutes of only no button switch activities Auto ranging lf the function selected has more than one range the meter will auto rang
26. nt for industrial use and some other equipment for example stationary motors with permanent connection to the fixed installation Measurement Category II CAT Il is for measurements performed on circuits directly connected to the low voltage installation Examples are measurements on household appliances portable tools and similar equipment WARNING To reduce the risk of fire or electric shock do not expose this product to rain or moisture To avoid electrical shock hazard observe the proper safety precautions when working with voltages above 60 VDC or 30 VAC rms These voltage levels pose a potential shock hazard to the user Do not touch test lead tips or the circuit being tested while power is applied to the circuit being measured Keep your fingers behind the finger guards of the test leads during measurement Inspect test leads and probes for damaged insulation or exposed metal before using the instrument If any defects are found replace them immediately INTERNATIONAL ELECTRICAL SYMBOLS Caution Refer to the explanation in this Manual Caution Risk of electric shock Earth Ground Double Insulation or Reinforced insulation Fuse AC Alternating Current DC Direct Current tE gt gt 3 Cenelec Directives The instrument conforms to CENELEC Low voltage directive 73 23 EEC and Electromagnetic compatibility directive 89 336 EEC MD 9010 General Purpose Auto Check Digital Multimeter Operation 4 Operation Note
27. racies with film Capacitor or RANGE Accuracy Burden Voltage better 2000uA 1 2 3d 6mV uA 11 MD 9010 General Purpose Auto Check Digitalmultimeter Specification AC uA Current MD 9010 RANGE Accuracy Burden Voltage 400 0uA 2 0 3d 6mV uA 2000uA 1 5 3d 6mV nA Audible Continuity Tester Open Circuit Voltage 0 4VDC typical Audible Threshold MD 9010 between 509 and 3009 Non Contact EF Detection MD 9010 Threshold Voltage Bar Graph Between 20V amp 80V _ 45v amp 125V le 70v amp 215V lee 20629 EEE 70 p Indication Bar graph segments amp audible beep tones proportional to the field strength Detection Frequency 50 60Hz Detection Antenna Top left corner of the meter Probe Contact EF Detection For more precise indication of live wires use the Red probe for direct contact measurements 12 MD 9010 General Purpose Auto Check Digitalmultimeter Limited warranty LIMITED WARRANTY METREL warrants to the original product purchaser that each product it manufactures will be free from defects in material and workmanship under normal use and service within a period of three years from the date of purchase METREL s warranty does not apply to accessories fuses fusible resistors spark gaps batteries or any product which in METREL s opinion has been misused altered neglected or damaged by accident or abnormal conditions of operation or handling To obtain warranty serv
28. s Messgeratesystems einen Microcontroller wie ein Computer WENN DAS MESSGER T EINGESCHALTET WIRD kann kurzzeitiger Batteriespannungsausfall schnelle Batteriekontaktunterbrechung in der Gr enordnung von Millisekunden einen unnormalen Reset Neustart des Messger ts verursachen Wenn eine solche Situation auftritt dr cken und halten Sie einfach die Taste SELECT etwa 6 Sekunden lang um das System mit einem Gesamt Reset zuruckzusetzen 20 MD 9010 Digitalmultimeter 6 Technische Daten ALLGEMEINE DATEN Anzeige und Aktualisierungsrate Betriebstemperatur Relative Luftfeuchtigkeit H henlage Lagerungstemperatur Temperaturkoeffizient Abtastung Verschmutzungsgrad Sicherheit berspannungsschutz Messkategorie EMV berlastschutz Schwache Batterie Stromversorgung Stromaufnahme typisch Stromaufnahme nach automatischer Abschaltung typisch Zeiten der automatischen Abschaltung Ma e Gewicht Sonderfunktionen Zubeh r Elektrische Daten Technische Daten MD 9010 3 5 6 Stellen 6000 Z hler nominal 5 Aktualisierungen pro Sekunde 0 C 40 C Maximale relative Luftfeuchtigkeit 80 bei Temperaturen bis 31 C linear abnehmend auf 50 relative Luftfeuchtigkeit bei 40 C Betrieb unter 2000 m 20 C 60 C lt 80 r F Batterie entfernt Nominal 0 15 x angegebene Genauigkeit C bei 0 C 18 C oder 28 C 40 C wenn nicht anders angegeben Mittelwertsab
29. t 100 dB bei Gleichspannung 50 Hz 60 Hz Rs 1 kQ schwelle fur Gleichspannungs AutoCheck gt 1 2 VDC oder lt 0 6 VDC nominal MD 9010 nur Gleichspannungs AutoCheck IMD 9010 nur hohe Impedanz Gleichspannung Wechselspannung MD 9010 BEREICH Genauigkeit 6 000 V 60 00 V 450 0 11 5 5 Dig Vv 600 0 V CMRR gt 60 dB bei Gleichspannung bis 50 Hz Rs 1 kQ Wechselspannung 160 kQ 160 pF nominal Eingangsimpedanz MD 9010 AutoCheck niedrige Impedanz Wechselspannung 833 kQ 4 2 kQ bei Anzeige Auto 90 pF nominal Hohe Impedanz Wechselspannung 5 MQ 90 pF nominal Schwelle fur Wechselspannungs AutoCheck gt 1 5 VAC 50 60 Hz nominal Bereich nur bei MD 9010 Technische Daten Kapazit t MD 9010 100 0 nF 1000 nF 10 00 uF 100 0 pF 2000 uF Genauigkeit unter 50 nF ist nicht spezifiziert Genauigkeiten bei Folienkondensatoren oder besser Aktualisierungen gt 1 Minute bei gro en Werten Nur MD 9010 Aktualisierungen gt 1 Minute bei gro en Werten Spezifiziert bei Batteriespannung ber 2 8V halb volle Batterie Die Genauigkeit sinkt allm hlich auf 12 bei der Batterieentladungs Warnspannung von ca 2 4 V 3 5 6 Dig Ohm MD 9010 BEREICH Genauigkeit 600 0 Q 2 0 6 Dig 6 000 kQ 6 000 M2 12 0 4 Dig Leerlaufspannung 0 4 VDC typisch 0 AutoCheck gilt bei Bereichen 6 000 KQ 6 000MQ 600 0
30. tastung 2 Erf llt IEC61010 1 UL61010B 1 CAN CSA C22 2 No 1010 1 92 4 kV Blitz berspannung 1 2 50 us MD 9010 CAT II 600V und CAT III 300V Erf llt EN61326 1997 1998 A1 EN61000 4 2 1995 und EN61000 4 3 1996 e In einem HF Feld von 3 V m e Kapazitatsfunktion ist nicht spezifiziert e Andere Funktionsbereiche e Gesamigenauigkeit spezifizierte Genauigkeit 45 Digits e Die Funktionsleistung oberhalb 3 V m ist nicht spezifiziert MD 9010 600 VDC und Ver Unter ca 2 4 V Standard Knopfzelle 3 V 1x IEC CR2032 ANSI NEDA 5004LC 6 mA bei Spannungsfunktionen in Position Auto VQ und 2 MA bei anderen Funktionen 2 2 uA MD 9010 3 Minuten Leerlauf L113mmxB53mmxH 10 2 mm ca 78g AutoCheck Automatische Wahl V und Q sowie Erkennung elektrischer Felder EF Batterie eingesetzt Gummihalter und Bedienungsanleitung mit Garantiererklarung Die Genauigkeit wird angegeben als der Anzeigestellen Anzahl Digits wenn nicht anders spezifiziert bei 23 C 5 C und weniger als 75 r F 21 MD 9010 Digitalmultimeter Gleichspannung MD 9010 BEREICH Genauigkeit 6 000 V 0 5 3 Dig 60 00 V 1 0 5 Dig 4500V 2 5 Dig 600 0 V 2 0 5 Dig 600 0 V 5 5 Dig Eingangsimpedanz MD 9010 AutoCheck niedrige Impedanz Gleichspannung 833 kQ 4 2 KQ bei Anzeige Auto 90 pF nominal Hohe Impedanz Gleichspannung 5 MQ 90 pF nominal NMRR gt 30 dB bei 50 Hz 60 Hz CMRR g

Download Pdf Manuals

image

Related Search

Bedienungsanleitung bedienungsanleitung bedienungsanleitung englisch bedienungsanleitungen pdf bedienungsanleitung sky receiver hd bedienungsanleitung deutsch bedienungsanleitung samsung bedienungsanleitung vw bedienungsanleitung samsung a16 5g bedienungsanleitung philips fernseher bedienungsanleitung jabra evolve2 65 bedienungsanleitung delonghi magnifica s bedienungsanleitung smart watch deutsch bedienungsanleitungen englisch bedienungsanleitung opel astra l bedienungsanleitung philips airfryer 3000 bedienungsanleitung auf englisch bedienungsanleitung philips kaffeevollautomat bedienungsanleitung iphone bedienungsanleitung alexa bedienungsanleitung erstellen bedienungsanleitung zeitschaltuhr bedienungsanleitung delonghi dinamica bedienungsanleitungen kostenlos in deutsch

Related Contents

Bedienungsanleitung TechniVision 22/26/32 ISIO  Performance Series 460e  Omega Blender B2100 User's Manual  User Manual - Interlogix  TRip configuration manual - AW Communication Systems Ltd.  支援情報管理装置クライアント等改修  Quick Setup Guide - Tri  Etonnant, ce que l`on peut peindre avec Diotrol!    ULTRAGAIN PRO MIC2200  