1. the settings of all connected devices in your room can comfortably be made via the MAX Wall Thermostatt Up to 8 MAX Radiator Thermostats and 8 MAX Window Sensors can be connected and controlled via the MAX Wall Thermos tatt The MAX Wall Thermostatt has an internal sensor that measures the temperature in the room and cyclically transmits it to the radiator thermostats 28 2 Operation and display I DAN W gt A Automatic mode Auto manual mode Manu holiday mode MM boost function EE open window function J B Temperature display current setpoint temperature C Reduction comfort temperature 382 battery empty symbol BETT antenna symbol radio synchronicity activity symbol 17t D Auto Manu button Switch between automatic and manual operation exit the holiday function E Boost button Activate the boost function confirm start teach in procedure F Switch between reduction and comfort temperature G Handwheel Make temperature settings 29 Information displayed during normal operation The current temperature is displayed during normal opera tion along with the mode In the exam ple on the right the MAX Radiator Thermostat is in automatic mode Auto and the comfort temperature 3 of 21 0 C is set The antenna symbol J indicates that the connection to the Auto UT u I taught in component has been established N
2. 30 3 Safety instructions Using this device for any purpose other than that described in this operating manual does not fall within the scope of intended use and shall invalidate any warranty or liability This also applies to any conversion or modification work This device is in tended for private use only This device is not a toy do not allow children to play with it Do not leave packaging material lying around as it can be dangerous in the hands of a child Do not open the device it does not contain any components that need to be serviced by the user In the event of an error please return the de vice to our service department The device may only be operated indoors and must be protected from the effects of damp and dust as well as solar or other methods of heat radiation 4 Instructions for Disposal Do not dispose of the device with regular domestic waste Electronic equipment must be disposed of at local collection points for waste electronic equipment in compliance with the Waste Electrical and Elec EE tronic Equipment Directive The CE Marking is simply an official symbol relat ing to the free movement of a product it does not warrant a product s characteristics regular domestic waste Instead take them to your local battery disposal point X ky Used batteries should not be disposed of with 5 Insert change batteries e Pull off the battery compartment cover e Insert 2 LR6 mignon AA
3. Drehen Sie den Thermostatkopf auf den Maximalwert A gegen den Uhrzeigersinn vgl S 10 Der Thermostatkopf dr ckt jetzt nicht mehr auf die Ventilspindel und kann so leichter demontiert werden Die Fixierung des Thermostatkopfes kann unterschiedlich ausgef hrt sein berwurfmutter Schrauben Sie die berwurfmutter gegen den Uhrzeigersinn ab B Danach k nnen Sie den Thermostatkopf abnehmen C Schnappbefestigungen Sie k nnen so befestigte Ther mostatk pfe einfach l sen indem Sie den Verschluss berwurfmutter ein klein wenig gegen den Uhrzeiger sinn drehen B Danach k nnen Sie den Thermostat kopf abnehmen C Klemmverschraubungen Der Thermostatkopf wird durch einen Befestigungsring gehalten der mit einer Schraube zusammengehalten wird L sen Sie diese Schraube und nehmen Sie den Thermostatkopf vom Ventil ab C VerschraubungmitMadenschrauben L sen Sie die Ma denschraube und nehmen Sie den Thermostatkopf ab C 10 Zur Montage auf Ventile von Danfoss ist einer der beilie genden Adapter erforderlich Die Zuordnung des passen den Adapterrings zum entsprechenden Ventil entnehmen Sie bitte den nachfolgenden Abbildungen Achten Sie darauf sich nicht die Finger zwischen den Adapterh lften einzuklemmen Die Ventilk rper von Danfoss weisen umlaufend l ngliche Einkerbungen E auf siehe Pfeil die auch einen besse ren Sitz des Adapters nach dem Aufrasten gew hrleisten Achten Sie bei der Mon
4. Sek If teach in has been successful the display returns to normal display 41 As soon asthe MAX Radiator Thermostat has been Gi taught in to a MAX Wall Thermostat all data such as date time or week programme are transmitted to it via radio connection The MAX Radiator Thermostat can only be taught in on one MAX Wall Thermostatt 9 Reset The MAX Radiator Thermostat can be reset to the initial state manually Restoring the initial state deletes all set tings and information about taught in devices A Before resetting the MAX Radiator Thermostat a please first delete the device from the local MAX software when using the installation with a MAX Cube First remove the batteries from the actuator e Wait 60 seconds Press and hold down the three buttons Auto Manu Boost 2 while you re insert the batteries e Once the factory settings have been restored success fully rES is displayed 10 Auto Manu To switch between operating modes press and immedi ately release the Auto Manu button the operating modes only become available for selection once installation is complete 42 e Auto Week programme automatic temperature regu lation in accordance with the time profile saved heat reduce A In the MAX House Solution you can individually set the week programmes via the MAX Software A In the MAX Room Solution you can individually set the week program
5. chst den MAX Cube in den Anlern modus Starten Sie dazu die lokale MAX Software und klicken Sie auf Neues Ger t 1 Zum Aktivieren des Anlernmodus am MAX Heizk r perthermostat dr cken Sie die Boost Taste l nger als 3 Sekunden 2 Im Display wird die verbleibende An lernzeit in Sekunden dargestellt Die Anlernzeit betr gt 30 Sekunden a wet ani Dan UIT oo Nach erfolgreichem Anlernen wechselt das Display zu r ck zur normalen Anzeige 17 Sobald der MAX Heizk rperthermostat am MAX Cube angelernt ist werden alle Daten wie Datum Uhrzeitoder Wochenprogramm per Funk bertragen Der MAX Heizk rperthermostat kann nur an einen MAX Cube angelernt werden Wurde der MAX Heizk rperthermostat bereits ber einen Wandthermostat konfiguriert muss vor dem ersten Anlernen an einen MAX Cube ein Werksre set durchgef hrt werden siehe Abschnitt 9 AN MAX Rauml sung In der Rauml sung k nnen alle Einstellungen und Programmierungen z B Wochenprogramme di rekt am MAX Wandthermostat vorgenommen werden Versetzen Sie zunachst den MAX Wandthermostatt ber einen langen Tastendruck l nger als 3 Sekunden der OK Taste in den Anlernmodus 1 Aktivieren Sie jetzt den Anlernmodus am MAX Heizk r perthermostat Dr cken Sie daf r die Boost Taste l nger als 3 Sekunden 2 Im Display wird die verbleibende An lernzeit in Sekunden dargestellt Die Anlernzeit betr gt 30 Sekunden 18 Au
6. ring Place the support ring G into the flange or onto the valve connection on the radiator and screw on the thermostat valve If the support ring cannot be fitted there is adequate sta bility and it is not needed for installation 38 7 Adapter run Once the batteries have been inserted the motor reverses meanwhile InS and the activity symbol f are displayed As soon as InS is displayed without the activity symbol 7t the electronic radiator thermostat can be mounted This is followed by an adapter run AdA to adapt the ther mostat to the valve e Attach the radiator thermostat to the valve e Tighten the union nut e Press the boost button when InS is displayed The actuator performs an adapter run AdA and the activity symbol f y are displayed during this time operation is not possible If the adapter run has been initiated prior to mounting or if an error message F1 F2 F3 is displayed press the Boost button the motor reverses to the InS position Teach in mode can be activated even whilst InS is still displayed 39 In order to enable to use the MAX Radiator Thermostat in your installation the device has the be taught in first The teach in procedure depends on the system variant used Choose your system variant and follow the instruc tions below A MAX House Solution In the MAX House Solution all settings and pro grammings e g week pro
7. 12 Dokumentation 2012 eQ 3 Ltd Hong Kong Alle Rechte vorbehalten BC RT TRX CyG V2 2 099017 1 Einleitung und bestimmungsgem er Einsatz Der MAX Heizk rperthermostat ist im MAX System f r das Regeln einzelner Heizkorper zustandig Beim Luften des Raumes regelt der MAX Heizk rperthermostat die Tem peratur automatisch herunter um Heizkosten zu sparen Die Kommunikation der MAX Komponenten untereinander erfolgt bidirektional Somit ist sichergestellt dass gesen dete Informationen den Empfanger erreichen Die Konfigurationen des MAX Heizkorperthermostat er folgt in Abhangigkeit von der genutzten Systemvariante Sie haben die Moglichkeit zwischen den folgenden zwei Varianten zu wahlen MAX Hauslosung fia Die MAX Hausl sung ist die L sung f r das ge samte Haus Mit einem MAX Cube kann die Kon figuration aller angelernten Ger te in Ihrem Haus bequem ber die MAX Software vorgenommen werden Durch den Einsatz des MAX Cubes k nnen mehrere MAX Heizk rperl sungen und MAX Rauml sungen in einer neu en Installation miteinander verbunden werden In der MAX Hausl sung ist es auch m glich den MAX Eco Taster als raum bergreifende Funktion einzusetzen MAX Rauml sung In der Rauml sung k nnen Sie die Konfiguration aller angelernten Ger te in Ihrem Raum komfor tabel ber den MAX Wandthermostat vorneh men Bis zu 8 MAX Heizk rperthermostate und 8 MAX Fensterkontakte k nnen ber den MAX Wand
8. Bedienungsanleitung Operating Manual eekE MAX Heizk rperthermostat Elektronischer Funk Heizk rperthermostat S 2 MAX Radiator Thermostat Electronic Wireless Radiator Thermostat p 27 Inhaltsverzeichnis 1 Einleitung und bestimmungsgem er Einsatz 3 2 Bedienung und Display 5 Display Inhalt im Normalbetrieb 6 3 SIGMSMMENSMINWEIS Os 5 ccccinsininoetnneenenoooisnCuebanudaadcegtinenntens 6 4 Ents rgunashinweise au 7 5 Batterien einlegen wechseln 7 6 Montage am Heizk rper aceunenennnnn 8 6 1 Demontage des alten Kopfes 242220 9 6 2 Adapter f r Danfoss ana a as 11 6 3 UZ CINE penrre a eee EAEE EEEE 15 7 Adaptierfahrt ses 16 SANNE Neree EEA REER EEEO Aa EEEE 17 9 Ablernien Resetl ae 19 19 21 DO I ANA zen 20 IN OO era ee 21 12 Komfort Absenktemperatul ccceeeeeeeeeeeeees 22 13 Kindersicherung Bediensperre ccccceeeeeeeees 23 14 Konfiguration des MAX Systems 000 23 15 Fehlerbehebung und Wartung ccccsseceeeeeeeees 24 16 Liefer and een 25 17 Hinweise zum Funkbetrieb uusss000s00eene nn 25 18 Technische Eigenschaften ccccccccsseeeeeeeseeees 26 Lesen Sie diese Anleitung sorgf ltig bevor Sie das Ger t in Be trieb nehmen Bewahren Sie die Anleitung zum sp teren Nach schlagen auf 1 Ausgabe Deutsch 03 20
9. Scope of delivery nee 46 16 Troubleshooting and maintenance 47 17 Information about radio operation 48 18 Technical charatterisiies n eanea 49 Read this manual carefully before starting to use the device Keep the manual so you can refer to it at a later date should you need to 1 English edition 03 2012 Documentation 2012 eQ 3 Ltd Hong Kong All rights reserved BC RT TRX CyG V2 2 099017 27 1 Introduction and intended use The MAX Radiator Thermostat is a component of the MAX system It is responsible for regulating single radiators Du ring ventilation the MAX Radiator Thermostat automati cally reduces the temperature to save costs for heating Communication between MAX components is bi direc tional This ensures that the information sent reaches the recipient The configuration of the MAX Radiator Thermostat is made according to the system variant used You have the possibility to choose between the following two variants MAX House Solution A MAX Net is the solution for the entire house With a MAX Cube all settings of connected devices in your house can be made via the MAX software By using the MAX Cube several MAX Radiator Solutions and MAX Room Solutions can be connected to a MAX House Solution in a new installation In this installation the MAX Eco Switch can optionally be integrated MAX Local the room solution In the room solution
10. batteries in the battery com partment making sure they are the right way round e Replace the battery compartment cover and latch it into position After inserting the batteries the radiator thermostat has to be mounted on the radiator first see chapter 6 After wards the radiator thermostat will start an adaptation run Further details can be found in chapter 7 A battery symbol BT indicates that the batteries need to be replaced After removing the batteries wait approx 1 minute before inserting the new ones This device does not support battery operation 31 The service life of new alkaline batteries is approx imately two years Using rechargeable batteries is not possible Never recharge standard batteries Doing so will A N present a risk of explosion Do not throw the batter ies into a fire Do not short circuit batteries 6 Mounting on a radiator The MAX Radiator Thermostat is easy to install and can be done without draining heating water or intervening in the heating system No special tools are required nor does the heating have to be switched off The union nut attached to the MAX Radiator Thermostat can be used universally and without accessories for all valves with a thread size of M30 x 1 5 from the most popu lar manufacturers such as Heimeier MNG Junkers Landis amp Gyr Duodyr Honeywell Braukmann Oventrop Schl sser Comap Valf Sanayii Mertik Maxitrol Watts Wingenroth Wirofle
11. bensdauer Display Empf ngerfrequenz Typische Freifeldreichweite Empf ngerklasse Wirkungsweise Schutzart Umgebungstemperatur Geh useabmessung Gewicht Anschluss Linearer Hub Federkraft Anlernbare Komponenten pro Raum Gruppe ber MAX Cube BC RT TRX CyG 3V 100 mA 2x LR6 Batterie Mignon AA ca 2 Jahre LC Display 868 3 MHz 100m SRD Class 2 Typ 1 IP 20 5 bis 55 C 60 x 65 x 100 mm BxHxT 170 g ohne Batterien M30 x 1 5 4 2mm max 80 N 1 MAX Wandthermostat 8 MAX Heizkorper thermostate und 8 MAX Fensterkontakte Technische Anderungen sind vorbehalten 26 Table of contents 1 Introduction and intended use uusussssesneennnnn 28 2 Operation and display nun 29 Information displayed during normal operation 30 3 Safety INSITUElONS 2er 30 4 Instructions for DISDOS Al sun reenen 31 5 Insert change batteries 2suu44uusseneeennnnnene en 31 6 Mounting on a ACIANOR csi naeeretecnemendinciunmaniant caciinwtin 32 6 1 Removing the old dial nen 33 6 2 Adapter for Danfoss nasse 34 6 3 Support TINO sie enter 38 Adapter rUe e EE E 39 es A Mie ere E EEE E 40 9 RESE 1 an DI EE E E 42 10 2UO Manta 42 T HS OO SU ee ars Eee 43 12 Comfort set back temperature cccccceeeeeeees 45 13 Child proof lock operating lock 45 14 Configuration of the MAX system 46 15
12. dually N adjust the boost duration via the MAX software In the MAX Room Solution you can individually adjust the boost duration via the MAX Wall Thermostat If the duration of the boost function via the MAX Ci Cube or the MAX Wall Thermostat is set so that the display exceeds 999 seconds the display value switches from seconds to minutes 12 Comfort set back temperature The comfort set back temperature button makes swit ching between comfort and set back temperature simple and user friendly The factory setting for the comfort tem perature is 21 0 C and the set back temperature 17 0 C The comfort and set back temperature can be changed individually Inthe MAX House Solution you can individually RB adjust the comfort set back temperature via the MAX software AN In the MAX Room Solution you can individually adjust the comfort set back temperature via the MAX Wall Thermostat gt 13 Child proof lock operating lock Operation of the device can be locked to avoid settings being changed unintended e g through involuntary touch To activate and deactivate the operating lock pro ceed as follows To activate deactivate the operating block press and immediately release the Auto Manu and 3 buttons simultaneously Once the block has been activated Loc is displayed for 10 s After this the temperature is displayed again The operation ofthe MAX Radiator Thermostat is n
13. e einstellen Wochenprogramme individuell uber den MAX Wandthermostat einstellen E a In der MAX Rauml sung k nnen Sie die e Manu Manueller Betrieb die manuell ber das Stell rad eingestellte Temperatur wird permanent gehalten ge ndert bernehmen alle dem Raum zugeh rigen G Wird der Betriebsmodus an einem Ger t im Raum MAX Heizk rperthermostate diese nderung 20 11 Boost Die Boost Funktion nutzt das menschliche W rmeempfin den Bei Aktivierung wird das Heizungsventil sofort f r 5 Minuten auf 80 ge ffnet Werkseinstellung Die Erw rmung eines Raumes dauert l nger als 5 Minu ten doch die vom Heizk rper abgegebene W rme kann sofort wahrgenommen werden Kommen Sie z B fr her nach Hause und m chten es schnell warm haben oder ben tigen Sie morgens nach dem Duschen extra W rme hilft Ihnen die Boost Funktion Dr cken Sie die Boost Taste zum Aktivieren der Funktion Die verbleibende Funktionsdauer wird im Sekundentakt heruntergez hlt 300 bis 000 W hrend die Funktion aktiv ist wird im Display dargestellt Solange der Stellstift des Heizk rperthermostats das Ventil ffnet schlie t wird das Aktivit tssymbol f y angezeigt Nach Ablauf der eingestellten Zeit wechselt der MAX Heizk rperthermostat wieder in den vorher aktiven Mo dus Auto Manu mit der vorher eingestellten Temperatur Die Funktion lasst sich jederzeit vorzeitig durch nochma liges Betatigen der Boo
14. etter seating of the adapter after it has been latched into place a When installing please ensure that the spigots inside the adapter D are in the same position as the inden tations E on the valve Latch the adapter which cor responds to the valve completely onto the valve body 34 The RA and RAV adapters have been produced with pre tension to aid better seating Use a screw driver during in stallation if necessary and bend these gently upwards in the area of the screw After they have been latched onto the valve body fasten the adapters with the enclosed screw and nut e When installing please ensure that the spigots inside the adapter D are in the same position as the inden tations E on the valve Latch the adapter which cor responds to the valve completely onto the valve body 35 With the RAV type of valve the tappet extension F should be placed on the valve pin before installation G When installing please ensure that the spigots inside the adapter D are in the same position as the inden tations E on the valve Latch the adapter which cor responds to the valve completely onto the valve body 36 The RAVL adapter does not have to be screwed on RAVL 37 The valves from different manufacturers may have tole rance fluctuations that make the MAX Radiator Thermo stat more loosely seated on the valve The stability and seating of the valve can be improved using the provided support
15. grammes can be made via the MAX software e Firstactivate the teach in mode of the MAX Cube Please start the local MAX software and click on New device e Now activate teach in mode on the MAX Radiator Ther mostat Press and hold down the Boost button for at least 3 seconds The teach in time remaining in seconds is displayed The teach in time is 30 seconds 1 MAX KUN eo Ge LE 14 03 2012 e If teach in has been successful the display returns to normal display As soon as the MAX Radiator Thermostat has been G taught in to the MAX Cube all data such as date time or week programme are transmitted to it via ra dio connection 40 The MAX Radiator Thermostat can only be taught inon one MAX Cube If the MAX Radiator Thermostat has already been configured with a MAX Wall Thermostat a factory reset must be performed prior to teaching in for the first time to a MAX Cube see section 9 MAX Room Solution In the MAX Room Solution all settings and pro grammings e g week programmes can be made via the MAX Wall Thermostatt First activate the teach in mode of the MAX Wall Ther mostat by pressing and holding down the Boost button of the MAX Wall Thermostat Now activate teach in mode on the MAX Radiator Ther mostat Press and hold down the Boost button for at least 3 seconds The teach in time remaining in seconds is displayed The teach in time is 30 seconds 1 gt 3
16. l verloren gegangen MAX Komponenten Schnell DutyCycle Limit Nach einer Stunde Wartezeit blinkendes erreicht kann das Ger t die Antennen Funkkommunikation wieder Symbol aufnehmen Bediensperre ist Deaktivieren Sie die aktiviert Bediensperre vgl Abschnitt 13 CAL Entkalkungsfahrt Automatische Funktion ist aktiv 16 Lieferumfang Heizk rperthermostat Adapter Danfoss RA Adapter Danfoss RAV St elverl ngerung Danfoss RAV Adapter Danfoss RAVL Zylinderkopfschraube M4 x 12 Mutter M4 St tzring 17 Hinweise zum Funkbetrieb Die Funk bertragung wird auf einem nicht exklusiven bertragungsweg realisiert weshalb St rungen nicht ausgeschlossen werden k nnen St reinfl sse k nnen u a durch Schaltvorg nge Elektromotoren oder auch de fekte Elektroger te hervorgerufen werden Die Reichweite in Geb uden kann stark von der im Frei feld abweichen Au er der Sendeleistung und den Emp fangseigenschaften der Empf nger spielen Umwelteinfl s se wie Luftfeuchtigkeit neben baulichen Gegebenheiten eine wichtige Rolle Hiermit erkl rt die eQ 3 Entwicklung GmbH dass sich die ses Ger t in bereinstimmung mit den grundlegenden An forderungen und den anderen relevanten Vorschriften der Richtlinie 1999 5 EG befindet Die vollst ndige Konformi t tserkl rung finden Sie unter www eQ 3 de 25 18 Technische Eigenschaften Kurzbezeichnung Versorgungsspannung Max Stromaufnahme Batterien Batteriele
17. m Einlegen der Batterien muss der Heizk rper thermostat zun chst am Heizk rper montiert werden sie he Kapitel 6 Anschlie end beginnt der Heizk rperther mostat mit einer Adaptierfahrt Details dazu finden Sie im Abschnitt 7 Ein Batteriesymbol BT weist darauf hin dass Sie die Batterien wechseln m ssen Nach Entnahme der Batte rien warten Sie ca 1 Minute bis zum Einlegen der neu en Batterien Die Lebensdauer neuer Alkali Batterien betr gt ca zwei Jahre Ein Betrieb mit Akkus ist nicht m glich Normale Batterien d rfen niemals aufgeladen wer den Es besteht Explosionsgefahr Batterien nicht ins Feuer werfen Batterien nicht kurzschlie en 6 Montage am Heizk rper Die Montage des MAX Heizk rperthermostat kann ohne Ablassen von Heizungswasser oder Eingriff in das Hei zungssystem erfolgen Spezialwerkzeug oder ein Abschal ten der Heizung sind nicht erforderlich Die am Heizk rperthermostat angebrachte berwurfmut ter ist universell einsetzbar und ohne Zubeh r passend f r alle Ventile mit dem Gewindema M30 x 1 5 mm der gan gigsten Hersteller wie z B Heimeier MNG Junkers Landis amp Gyr Duodyr Honeywell Braukmann Oventrop Schlosser Comap Valf Sanayii Mertik Maxitrol Watts Wingenroth Wiroflex R B M Tiemme Jaga Siemens Idmar Durch die im Lieferumfang enthaltenen Adapter ist das Ge r t auf Heizk rperventile vom Typ Danfoss RA Danfoss RAV und Danfoss RAVL montierbar
18. mes via the MAX Wall Ther mostat e Manual operation the temperature set manually using the handwheel is maintained permanently If the operating mode is changed on one device ina room this change is applied on all radiator thermo stats assigned to that room 11 Boost The boost function makes use of human sensations of heat When the function is activated the heating valve opens im mediately for 5 minutes at 80 factory setting You can feel the heat from the radiator immediately and at the end of the 5 minutes the room continues to heat up If you arrive home earlier than usual and want to heat the room up quickly or you need some extra heat in the morning after a shower then the boost function will help you with this 43 Press the Boost button to activate the boost function The remaining time for the function is counted down in seconds 300 to 000 Whilst the function is active is displayed The activity symbol 9 is displayed as long as the ad justing pin opens closes the valve Once the set time has elapsed the radiator thermostat switches back to the mode that was active previously automatic manual with the temperature that was set previously The function can be deactivated prematurely at any time by pressing the Boost button again The function will not have an immediate effect if the radiator is covered or concealed e g bya sofa In the MAX House Solution you can indivi
19. ng erscheint f r 10 Sek Loc im Display anschlie end wird wieder die Temperatur angezeigt e Die Bedienung des MAX Heizk rperthermostat ist jetzt gesperrt e Zum Deaktivieren der Bediensperre dr cken Sie beide Tasten erneut 14 Konfiguration des MAX Systems A Wenn Sie den MAX Heizkorperthermostat in der MAX Hausl sung nutzen k nnen Sie die individuellen Einstellungen Ihres MAX Systems z B Konfiguration der Wochenprogramme ber die MAX Software vornehmen Wenn Sie den MAX Heizk rperthermostat in der MAX Rauml sung nutzen k nnen Sie die individuellen Einstellungen Ihres MAX Systems z B Konfiguration der Wochenprogramme ber den MAX Wandthermostat vornehmen PN 23 15 Fehlerbehebung und Wartung im Display symbol gt zu gering F1 Ventilantrieb Installation pr fen pr fen schwerg ngig ob Stift des Heizungsventils klemmt F2 Stellbereich zu a ce Stellantriebs berpr fen Stellbereich zu Heizungsventil berpr fen klein pr fen ob Stift des Heizungsventils klemmt F3 F4 Bereits ein MAX Stellen Sie sicher dass das Cube MAX Ger t nicht mehr am Cube Wandthermostat in der Software bzw am angelernt Wandthermostast angelernt ist und f hren Sie einen Reset durch Anschlie end k nnen Sie das Ger t erneut anlernen Langsam Verbindung zu berpr fen Sie die blinkendes angelernten MAX Spannungsversorgung und Antennen Komponenten ist die Batterien angelernter Symbo
20. ow locked To deactivate the lock press both buttons again 45 If you use your MAX Radiator Thermostat in the MAX House Solution you can individually adjust your heating system e g configuration of week programmes via the MAX software m If you use your MAX Radiator Thermostat in the gt MAX Room Solution you can individually adjust your heating system e g configuration of week programmes via the MAX Wall Thermostat MAX Radiator Thermostat Adapter Danfoss RA Adapter Danfoss RAV Lifter extension Danfoss RAV Adapter Danfoss RAVL Cylinder head screw M4 x 12 nut M4 Support ring 16 Troubleshooting and maintenance mape pe the display gt too low Check the installation check sluggish whether the pin on the heating valve is stuck too wide actuator F4 Actuating range Check the heating valve too narrow check whether the valve pin is jammed A MAX Cube Make sure that the device or MAX Wall is not taught in to the MAX Thermostat has Cube in the software or already been the MAX Wall Thermostat taught in and reset the device You can repeat the teach in procedure afterwards Antenna symbol Connection to Check the power supply and G flashing taught in MAX batteries to taught in MAX slowly Components lost Components Antenna symbol Duty cycle has The longest period to wait G flashing been exceeded before sending again would fastly be an hour CAL Ro
21. st Taste deaktivieren Die Funktion hat keinen unmittelbaren Effekt wenn der Heizk rper verdeckt ist z B durch ein Sofa In der MAX Hausl sung k nnen Sie die Boost Dauer individuell ber die MAX Software einstellen 21 A In der MAX Rauml sung k nnen Sie die Boost Dauer individuell ber den MAX Wand thermostat einstellen Ist die Dauer der Boost Funktion ber den MAX Cube oder den MAX Wandthermostat so eingestellt dass die Anzeige im Display eine Sekundenanzeige von 999 Sekunden berschrei tet wird sie nicht mehr in Sekunden sondern in Minuten dargestellt 12 Komfort Absenktemperatur Die Taste Komfort Absenktemperatur s dient zur kom fortablen und einfachen Umschaltung zwischen diesen bei den Temperaturen Werkseitig liegt die Komforttemperatur bei 21 0 C und die Absenktemperatur bei 17 0 C In der MAX Hausl sung k nnen Sie die AN Komfort und Absenktemperatur individuell ber die MAX Software einstellen Komfort und Absenktemperatur individuell ber den MAX Wandthermostat einstellen i E SEPEN A In der MAX Rauml sung k nnen Sie die 22 13 Kindersicherung Bediensperre Die Bedienung am Ger t kann gesperrt werden um das ungewollte Ver ndern von Einstellungen z B durch ver sehentliches Ber hren zu verhindern e Um die Bediensperre zu aktivieren deaktivieren sind die Tasten Auto Manu und E amp gleichzeitigkurzzu dr cken e Nach Aktivieru
22. t o Man Ty ER DD Ha iga Nach erfolgreichem Anlernen wechselt das Display Sure zur normalen Anzeige Sobald der MAX Heizk rperthermostat am MAX Wandthermostat angelernt ist werden alle Daten wie Datum Uhrzeit oder Wochenprogramm per Funk bertragen Der MAX Heizk rperthermostat kann nur an einen MAX Wandthermostat angelernt werden 9 Ablernen Reset Der Auslieferungszustand des MAX Heizk rperthermo stats kann manuell wieder hergestellt werden Dabei ge hen alle Einstellungen und Informationen ber angelernte Ger te verloren Werkzustand zur cksetzen l schen Sie das Ger t beim Betrieb mit dem MAX Cube zuerst aus der lokalen MAX Software Bevor Sie den MAX Heizk rperthermostat in den 19 e Entnehmen Sie zun chst die Batterien aus dem MAX Heizk rperthermostat e Warten Sie 60 Sekunden e Halten Sie anschlieRend die drei Tasten Auto Manu Boost 38 gedr ckt w hrend Sie die Batterien wieder einlegen e Nach erfolgreichem Wiederherstellen der Werkseinstel lungen wird rES im Display angezeigt 10 Auto Manu Mit kurzem Druck der Auto Manu Taste kann zwischen den Betriebsmodi gewechselt werden die Betriebs Modi sind erst nach der Installation auswahlbar e Auto Wochenprogramm automatische Temperatur regelung gem dem hinterlegten Zeitprofil Heizen Absenken In der MAX Hausl sung k nnen Sie die Wochenprogramme individuell uber die MAX Softwar
23. tage bitte darauf dass die Zapfen im Inneren des Adapters D eine deckungsgleiche Positi on zu den Einkerbungen E am Ventil haben Rasten Sie den zum Ventil passenden Adapter vollst n dig auf 11 Die Adapter RA und RAV wurden Zugunsten eines besse ren Sitzes mit Vorspannung produziert Bei Montage ver wenden Sie ggf einen Schraubendreher und biegen diese im Bereich der Schraube leicht auf Nach dem Aufrasten auf den Ventilk rper befestigen Sie die Adapter bitte mit der beiliegenden Schraube und Mutter Gi Achten Sie bei der Montage bitte darauf dass die Zapfen im Inneren des Adapters D eine deckungs gleiche Position zu den Einkerbungen E am Ventil haben 12 Rasten Sie den zum Ventil passenden Adapter vollst n dig auf Auf Ventile vom Typ RAV ist vor der Montage die Stofel verl ngerung F auf den Ventilstift aufzusetzen o Achten Sie bei der Montage bitte darauf dass die Zapfen im Inneren des Adapters D eine deckungs gleiche Position zu den Einkerbungen E am Ventil haben Rasten Sie den zum Ventil passenden Adapter voll st ndig auf 13 Der Adapter RAVL muss nicht verschraubt werden RAVL Bei den Ventilen einiger Hersteller weist der in das Ger t hineinragende Teil des Ventils nur einen geringen Durch messer auf was zu einem lockeren Sitz f hrt In diesem Fall sollte der beiliegende St tzring G vor der Montage in den Flansch des Ger tes eingelegt werden 15 7 Adap
24. thermostatt angelernt und gesteuert werden Der MAX Wandthermo statt verf gt ber einen internen Sensor der die Tempe ratur im Raum misst und zyklisch an die Heizk rperther mostate bermittelt Diese L sung kann mit einem MAX Cube zur Hausl sung erweitert werden 2 Bedienung und Display I DAN W gt A Automatischer Modus Auto Manueller Modus Manu Urlaubsmodus MM Boost Funktion EISi Fenster auf Funktion f B Anzeige der Solltemperatur C Absenk Komforttemperatur 386 Batterie leer Symbol 8 Antennensymbol Funksynchronitat Aktivi t tssymbol 79 D Auto Manu Taste Wechsel zwischen Auto und Manu Betrieb Verlassen der Urlaubsfunktion E Boost Taste Aktivierung der Boost Funktion Best tigen Anlernvorgang starten F Umschalten zwischen Absenk und Komforttemperatur G Stellrad f r Temperatur Einstellungen Display Inhalt im Normalbetrieb Im Normalbetrieb wird die Solltemperatur zusammen mit dem Modus angezeigt Im Beispiel befindet sich der MAX Heizk rperthermostat im automatischen Modus Auto als Temperaturvorgabe ist die Komforttemperatur es von 21 0 C eingestellt Das Antennensymbol weist darauf hin dass die Verbindung zur angelernten Kompo nente besteht LI 3 Sicherheitshinweise Jeder andere Einsatz als der in dieser Bedienungs anleitung beschriebene ist nicht bestimmungsge m und f hrt zu Garantie und Haf
25. tierfahrt Nach dem Einlegen der Batterien und dem Einstellen von Datum und Uhrzeit f hrt der Motor zun chst zur ck w h renddessen wird InS und das Aktivit tssymbol 74 ange zeigt Sobald InS ohne Aktivit tssymbol 4 im Display steht kann der Heizk rperthermostat montiert werden Danach wird zur Anpassung ans Ventil eine Adaptierfahrt AdA durchgef hrt e Setzen Sie den Heizkorperthermostat auf das Ventil e Ziehen Sie die berwurfmutter fest e Drucken Sie die Boost Taste wenn im Display InS steht Der Heizk rperthermostat f hrt eine Adaptierfahrt durch Dabei werden AdA und das Aktivit tssymbol 79 im Display angezeigt w hrenddessen ist keine Bedienung m glich Wurde die Adaptierfahrt vor der Montage eingeleitet bzw wird eine Fehlermeldung F1 F2 F3 angezeigt dr cken Sie die Boost Taste und der Motor f hrt zur ck zur Posi tion InS Der Anlernmodus l sst sich auch w hrend InS im Display steht aktivieren 16 Um den MAX Heizk rperthermostat in Ihrer Installation nutzen zu k nnen muss er zun chst angelernt werden Der Anlernvorgang unterscheidet sich nach der von Ihnen genutzten Systemvariante W hlen Sie Ihre Systemvari ante und folgen Sie den Anweisungen Az MAX Hauslosung In der MAX Hausl sung k nnen alle Einstellun gen und Programmierungen z B Wochenpro gramme direkt ber die MAX Software vorge nommen werden Versetzen Sie zun
26. ts that can be taught in via MAX Cube 1 MAX Wall Thermostat 8 Radiator Thermostats 8 Window Sensors Subject to technical changes 49 50 51 e ekEF eQ 3 AG Maiburger Stra e 29 D 26789 Leer www eQ 3 de
27. tungsaus schluss Dies gilt auch f r Umbauten und Ver nde rungen Die Ger te sind ausschlie lich f r den pri vaten Gebrauch gedacht Das Ger t ist kein Spielzeug erlauben Sie Kindern nicht damit zu spielen Lassen Sie Verpackungs material nicht achtlos liegen dies kann f r Kinder zu einem gef hrlichen Spielzeug werden ffnen Sie das Ger t nicht es enth lt keine durch den An wender zu wartenden Teile Im Fehlerfall schicken Sie das Ger t an den Service Betreiben Sie das Ger t nur in Innenr umen und vermeiden Sie den Einfluss von Feuchtigkeit Staub sowie Sonnen oder W rmebestrahlung 4 Entsorgungshinweise Ger t nicht im Hausm ll entsorgen Elektronische Ger te sind entsprechend der Richt RX linie ber Elektro und Elektronik Altger te ber die rtlichen Sammelstellen f r Elektronik Altge um te zu entsorgen Das CE Zeichen ist ein Freiverkehrszeichen das sich ausschlie lich an die Beh rden wendet und keine Zusicherung von Eigenschaften beinhaltet Hausm ll Entsorgen Sie diese in Ihrer rtli chen Batteriesammelstelle X ky Nerbrauchte Batterien geh ren nicht in den 5 Batterien einlegen wechseln Legen Sie die Batterien in den MAX Heizk rperthermo stat ein e Ziehen Sie den Batteriefachdeckel nach vorne ab e Legen Sie 2 LR6 Batterien Mignon AA polungsrichtig in das Batteriefach ein e Setzen Sie den Batteriefachdeckel wieder auf und ras ten Sie ihn ein Nach de
28. utine descaling Automatic function is active 47 17 Information about radio operation Radio transmission is performed on a non exclusive transmission path which means that there is a possibility of interference occurring Interference can also be caused by switching operations electrical motors or defective electrical devices The range of transmission within buildings can differ greatly from that available in the open air Besides the transmitting power and the reception characteristics of the receiver environmental factors such as humidity in the vi cinity have an important role to play as do on site structu ral screening conditions eQ 3 Entwicklung GmbH hereby declares that this de vice complies with the essential requirements and other relevant regulations of Directive 1999 5 EC You can find the full declaration of conformity at www eQ 3 de 48 18 Technical characteristics Short description Supply voltage Max current consumption Batteries Battery life Display Receiver frequency Typical open air range Receiver class Method of operation Degree of protection Ambient temperature Housing dimensions Weight Connection Linear travel Spring force BC RT TRX CyG 3V 100 mA 2x LR6 batteries mignon AA 2 years approx LCD 868 3 MHz 100 m SRD Class 2 Type 1 IP20 5 to 55 C 60 x 65 x 100 mm WxHxD 170 g without batteries M30 x 1 5 4 2 mm Max 80 N Componen
29. x 32 R B M Tiemme Jaga Siemens Idmar By means ofthe adapters in the delivery the device can be installed on radiator valves of type Danfoss RA Danfoss RAV and Danfoss RAVL Rotate the thermostat dial to the maximum value A an ti clockwise The thermostat dial then no longer presses against the valve spindle making it easier to remove There are different ways of fixing the position of the ther mostat dial Union nut Unscrew the union nutin an anticlockwise di rection B Then you can remove the thermostat head C Snap on fastenings Thermostat dials that have been attached using this method can be easily released by gi ving the lock union nut a slight turn in the anticlockwise direction B The thermostat dial can then be removed C Compression fittings The thermostat dial is held in place by a mounting ring which is held together with a screw Slacken this screw and remove the thermostat dial from the valve C Screwed on with a grub screw Slacken the grub screw and remove the thermostat dial C 33 One of the enclosed adapters is required for installation on Danfoss valves The arrangement of the suitable ad apter ring for the appropriate valve can be found in the following figures Take care during installation that you do not trap your fingers between the two halves of the adapter The Danfoss valve bodies have elongated indentations E running all around see arrow which also ensure b