Home

Bedienungsanleitung / Operation Manual Festspannungs

image

Contents

1. Binding Post Cooling Fan Variable speed AC Power Input Connector Cover Fuse Holder Fine tune access port at the base plate Range 13 3 14 5 V 13 a Installation This power supply is designed for indoor use only put the unit in a well ventilated place and allow at least 50mm 2 in space on two sides and the back to allow sufficient fan Check for the correct input AC voltage with the rating label on the power supply cooling Make sure your mains plug is of 3 pin version and the ground pin is effective as the grounding of the power supply will prevent electrical shock caused by leakage Turn on the power supply for a few minutes the power switch 1 should be lit and the indicator 2 should be in green Turn off the power supply and connect the equipment with correct polarity Turn on the power supply first and then turn on the equipment When the operation is finished turn off the equipment first and then turn off the power supply 14 5 Fine Tuning the output Voltage 13 3 14 5 V This regulated power supply has been factory preset at a stable DC output Rarely you need to do any fine tuning under normal operation However should the need for specific precise output voltage other than the preset voltage is required refer to the following procedure Bottom View O 4 1 Let the power supply warm up for about 15 min 2 Turn the power supply over with the bottom up and c
2. PeakTech Pr f und Messtechnik Spitzentechnologie die berzeugt PeakTech 6100 Bedienungsanleitung Operation Manual Festspannungs Schaltnetzteil Fixed Voltage Switching Mode Power Supply 1 Sicherheitshinweise zum Betrieb des Gerates Dieses Ger t erf llt die EU Bestimmungen 2004 108 EG elektromagnetische Kompatibilit t und 2006 95 EG Niederspannung entsprechend der Festlegung im Nachtrag 2004 22 EG CE Zeichen Verschmutzungsgrad 2 Zur Betriebssicherheit des Ger tes und zur Vermeidung von schweren Verletzungen durch Strom oder Spannungs berschl ge bzw Kurzschl sse sind nachfolgend aufgef hrte Sicherheitshinweise zum Betrieb des Ger tes unbedingt zu beachten Sch den die durch Nichtbeachtung dieser Hinweise entstehen sind von Anspr chen jeglicher Art ausgeschlossen Dieses Ger t darf nicht in hochenergetischen Schaltungen verwendet werden Vor Anschluss des Ger tes an eine Steckdose berpr fen dass die Spannungseinstellung am Ger t mit der vorhandenen Netzspannung bereinstimmt Ger t nur an Steckdosen mit geerdetem Schutzleiter anschlie en Ger t nicht auf feuchten oder nassen Untergrund stellen Ventilationsschlitze im Geh use unbedingt freihalten bei Abdeckung Gefahr eines W rmestaus im Inneren des Ger tes Keine metallenen Gegenst nde durch die Ventilationsschlitze stecken Keine Fl ssigkeiten auf dem Ger t abstellen Kurzschlussgefahr beim Umkippen des Ge
3. ater gets inside the equipment to prevent possible shorts and damage to the equipment 11 2 Introduction This fixed voltage switching mode power supply is designed with high RFI stability especially for DC operated radio equipment It is also suitable for a variety of applications that need a clean DC source The concealed trimmer allows fine tuning of output voltage range of 13 3 14 5V for PeakTech 6100 Constant current circuitry is used for overload short circuit and over temperature protection Output voltage and current would drop to a safety value when any of the faults occur and the DC output ON indicator will turn off This power supply also has Over Voltage Protection to prevent your connected equipment from damage by abnormal high output voltage Please read through this manual and pay special attention to the caution and safety precautions Keep this manual in an easy to find place for future reference Cautions DO NOT use this power supply for high inductive load such as solenoid or motorized equipment because of the inductive kick back from the output may damage the power supply DO NOT operate power supply immediately with a newly replaced fuse before the fault has been found and rectified Make sure to use the same rating and type as the original fuse 12 3 Panel Description ANAAARwWMYM gt Dt outeur On Off Switch with Light DC Output ON Indicator Car cigar socket Main DC Output
4. ie einen schmalen Schraubendreher zu den Einstellarbeiten 5 Drehen Sie den Schraubendreher Vorsichtig und langsam im Uhrzeigersinn oder gegen den Uhrzeigersinn und achten Sie dabei auf die im Multimeter angezeigte Ausgangsspannung 6 Erneut messen die Ausgangsspannung abschlie end erneut und drehen Sie das Netzteil wieder in die Ausgangsposition 7 6 Technische Daten Ausgangsspannung Ausgangsstrom Hauptausgangssockel Restwelligkeit Netzregelung Lastregelung Spannungseingang K hlsystem Abmessungen BxHxT Gewicht 13 8 V DC Fest 0 5 V 23 A dauer 25 A max 1min 50 Arbeitszyklus lt 50 MVss 5 MVer lt 50 mV 410 Variation lt 100 mV 0 100 Last 230 V AC 50 Hz Drehzahlgeregelter L fter 181 x 63 x 190 mm ca 1 7kg ca 3 7 Lbs Alle Rechte auch die der Ubersetzung des Nachdruckes und der Vervielfaltigung oder Teilen daraus vorbehalten Reproduktion jeder Art Fotokopien Mikrofilm oder ein anderes Verfahren nur mit schriftlicher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische Anderungen des Ger tes welche dem Fortschritt dienen vorbehalten Hiermit best tigen wir dass alle Ger te die in unseren Unterlagen genannten Spezifikationen erf llen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von 1 Jahr wird empfohlen PeakTech 03 2013 Th 1 Safety Precautions This product complies with the
5. llen das Ger t in einem gut bel fteten Ort auf und lassen Sie mindestens 50 mm 2 Zoll Platz auf allen Seiten damit der L fter arbeiten kann Pr fen Sie ob die richtige Netzspannung siehe Typenschild am Netzteileingang anliegt Vergewissern Sie sich dass der Netzstecker bautechnisch die gleiche 3 Pin Version mit Erdungsstift hat um elektrische Schl ge und Kriechstr me zu vermeiden Schalten Sie die Stromversorgung ein sollten der Schalter und die Kontrolldiode gr n leuchten Schalten Sie das Netzteil aus und verbinden Sie den Verbraucher mit richtiger Polarit t Schalten Sie erst das Netzteil ein danach erst den Verbraucher Wenn der Vorgang beendet ist schalten Sie zun chst den Verbraucher aus und erst dann das Netzteil 5 Feineinstellung der Ausgangsspannung 13 3 14 5 V Die geregelte Stromversorgung ist werksseitig auf eine stabile Gleichspannung eingestellt worden Selten m ssen Sie die Feinabstimmung im normalen Betrieb vornehmen sollte allerdings die Notwendigkeit einer anderen Ausgangsspannung bestehen entnehmen Sie ihr Vorgehen dem folgenden Absatz Unterseite des Ger tes 1 Lassen Sie das Netzteil f r ca 15 min warmlaufen 2 Stellen Sie das Netzteil auf Kopf und verbinden Sie ein digitales Multimeter DMM mit mindestens 2 Nachkommastellen mit den Ausgangsbuchsen 3 Suchen Sie die Offnung f r das Feinabstimmungspotentiometer auf der Unterseite wie in Abb 1 dargestellt 4 Benutzen S
6. ns We recommend to calibrate the unit again after 1 years PeakTech 03 2013 Th PeakTech Priif und Messtechnik GmbH Kornkamp 32 DE 22926 Ahrensburg Germany T 49 0 4102 42343 44 49 0 4102 434 16 info peaktech de www peaktech de
7. onnect a digital Multimeter DMM with at least 2 decimal read out to the main output terminal 4 3 Locate the fine tune access hole 8 on the bottom as shown in Fig 1 4 Insert a slim flat head screw driver to get to the trimmer as shown in Fig 1 5 Carefully and slowly turn the screw driver clockwise or anti clockwise while keeping an eye on the DMM for your desired voltage setting 7 5 6 Measure again the output voltage to re confirm your new setting after returning the power supply to its normal operation position SPECIFICATIONS Output voltage Output current Main output post Ripple and noise Line regulation Load regulation Power source Cooling system Dimensions WxHxD Weight fixed 13 8V DC 0 5 V 23 A Continuous 25 A max 1 min 50 duty cycle lt 50 MV op 5 MVims lt 50 mV 10 Variation lt 100 mV 0 100 load 230V AC 50 Hz Forced air cooling by variable speed cooling fan 181 x 63 x 190 mm approx 1 7 kg approx 3 7 Lbs 16 All rights also for translation reprinting and copy of this manual or parts are reserved Reproduction of all kinds photocopy microfilm or other only by written permission of the publisher This manual considers the latest technical knowing Technical changings which are in the interest of progress reserved We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specificatio
8. r tes Ger t nicht in der N he starker magnetischer Felder Motoren Transformatoren usw betreiben Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist Defekte Sicherungen nur mit einer dem Originalwert entsprechenden Sicherung ersetzen Sicherung oder Sicherungshalter niemals kurzschlie en Ger t Pr fleitungen und sonstiges Zubeh r vor Inbetriebnahme auf eventuelle Sch den bzw blanke oder geknickte Kabel und Dr hte berpr fen Im Zweifelsfalle keine Messungen vornehmen Verwenden Sie ausschlie lich 4mm Sicherheitstestkabels tze um eine einwandfreie Funktion des Ger tes zu gew hrleisten Messarbeiten nur in trockener Kleidung und vorzugsweise in Gummischuhen bzw auf einer Isoliermatte durchf hren Warnhinweise am Ger t unbedingt beachten Ger t darf nicht unbeaufsichtigt betrieben werden Ger t keinen extremen Temperaturen direkter Sonneneinstrahlung extremer Luftfeuchtigkeit oder N sse aussetzen Starke Ersch tterung vermeiden Hei e L tpistolen aus der unmittelbaren N he des Ger tes fernhalten Vor Aufnahme des Messbetriebes sollte das Ger t auf die Umgebungstemperatur stabilisiert sein wichtig beim Transport von kalten in warme R ume und umgekehrt S ubern Sie das Geh use regelm ig mit einem feuchten Stofftuch und einem milden Reinigungsmittel Benutzen Sie keine tzenden Scheuermittel Dieses Ger t ist ausschlie lich f r Innenanwend
9. requirements of the following European Community Directives 2004 108 EC Electromagnetic Compatibility and 2006 95 EC Low Voltage as amended by 2004 22 EC CE marking To ensure safe operation of the equipment and eliminate the danger of serious injury due to short circuits arcing the following safety precautions must be observed Damages resulting from failure to observe the safety precautions are exempt from any legal claims whatever Prior to connection of the equipment to the main outlet check that the available mains voltage corresponds to the voltage setting of the equipment Connect the main plugs of the equipment only to a mains outlet with earth connection Do not exceed the maximum permissible input rating Replace a defective fuse only with a fuse of the original rating Never short circuit fuse or fuse holding Disconnect test leads or probe from the measuring circuit before switching models or functions Check the test leads and probes for faulty insulation or bare wires before connection to the equipment Do not cover the ventilation slots of the cabinet to ensure that the air is able to circulate freely inside Do not insert metal objects into the equipment by way of the ventilation slots Do not place water filled containers on the equipment danger of short circuit in case of know over the container To avoid electrical shock do not operate this product in wet or damp conditions Conduct mea
10. suring works only in dry clothing and rubber shoes i e on isolating mats Never touch the tips of the test leads or probe Comply with warning labels and other info on the equipment 10 Do not subject the equipment to direct sunlight or extreme temperatures humidity or dampness Do not subject the equipment to shocks or strong vibrations Do not operate the equipment near strong magnetic fields motors transformers etc Keep hot soldering irons or guns away from the equipment Allow the equipment to stabilise at room temperature before taking up measurement important for exact measurements Periodically wipe the cabinet with a damp cloth and mid detergent Do not use abrasives or solvents The meter is for indoor use only Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage Do not store the meter in a place of explosive inflammable substances Do not modify the equipment in any way Opening the equipment and service and repair work must only be performed by qualified service personnel The instrument must be set so that the power plug can be removed from the socket easily Measuring instruments don t belong to children hands Cleaning the cabinet Prior to cleaning the cabinet withdraw the mains plug from the power outlet Clean only with a damp soft cloth and a commercially available mild household cleanser Ensure that no w
11. ungen geeignet Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen Dieses Ger t ist ausschlie lich f r Innenanwendungen geeignet Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen Offnen des Ger tes und Wartungs und Reparaturarbeiten d rfen nur von qualifizierten Service Technikern durchgef hrt werden Ger t nicht mit der Vorderseite auf die Werkbank oder Arbeitsfl che legen um Besch digung der Bedienelemente zu vermeiden Keine technischen Ver nderungen am Ger t vornehmen 2 Niemals die Bel ftungsschlitze verdecken Messger te geh ren nicht in Kinderh nde Reinigung des Ger tes Vor dem Reinigen des Ger tes Netzstecker aus der Steckdose ziehen Ger t nur mit einem feuchten fusselfreien Tuch reinigen Nur handels bliche Sp lmittel verwenden Beim Reinigen unbedingt darauf achten dass keine Fl ssigkeit in das Innere des Ger tes gelangt Dies k nnte zu einem Kurzschluss und zur Zerst rung des Ger tes f hren 2 Einf hrung Dieses Festspannungs Schaltnetzteil wurde mit hoher RFI Stabilit t entworfen und ist besonders f r Gleichspannungsbetriebene Funkanlagen geeignet Es ist auch f r eine Vielzahl von anderen Anwendungen geeignet die eine saubere DC Quelle brauchen Das verdeckt angebrachte Potentiometer erm glicht die Feinabstimmung der Ausgangsspannung von 13 3 bis 14 5 V Die Konstantstrom Schaltung ist ausgelegt f r berlast Kur
12. zschluss und bertemperaturschutz Sollte einer dieser Fehler auftreten werden die Spannungs und Stromwerte auf einen sicheren Wert zur ckgefahren und die DC Ausgang EIN Leuchte erlischt Dieses Netzteil bietet auch einen berspannungsschutz f r Ihre angeschlossenen Ger te um sie vor Sch den zu durch eine zu hohe Ausgangsspannung zu sch tzen Bitte lesen Sie dieses Handbuch gut durch und achten Sie besonders auf die Vorsichts und Sicherheitsma nahmen Bewahren Sie diese Anleitung gut auf um sie zum sp teren Nachschlagen schnell zu finden Vorsicht Benutzen Sie dieses Netzteil nicht f r hohe induktive Lasten wie Magnetspule oder motorisierte Ger te welche aufgrund des induktiven R ckschlags den Ausgang das Netzteils besch digen k nnen Sollte die Ger tesicherung ausl sen benutzen Sie das Ger t nach Austausch nicht sofort wieder sondern vergewissern Sie sich dass der Fehler hierf r gefunden und behoben wurde Benutzen Sie nur Sicherungen der gleichen Charakteristik und mit den gleichen Sicherungswerten 3 Anzeigen und Bedienelemente Dt outeur Beleuchteter On Off Schalter DC Ausgang EIN Indikator KFZ Zigarettenanz nderbuchse Haupt Gleichspannungsausgang L fter variable Geschwindigkeit AC Netzeingang Sicherungshalter Feinabstimmung f r Spannungsausgang an der Bodenplatte Bereich 13 3 14 5 V A Installation Dieses Netzteil ist nur f r den Innenbereich konzipiert ste