1. REINE Ga Qs After pressing the RESET key during reset the display screen first of all shows H z z H H iy all the lit up digits and then all the digits that are not lit up Gu Cal ABBA B At the end of the process a display page is first of all shown with the reset Partial and the Reset Total and after a few moments the Reset Total is replaced by the NON resettable Total Total The Reset Total resetting operation can only be performed after resetting the Partial register The Reset Total can in fact be reset by pressing the RESET key at length while the display screen shows RESET TOTAL as on the following display page Schematically the steps to be taken are 1 Wait for the display to show normal standby display page with Total only displayed 2 Press the RESET key quickly 3 The meter starts to reset the Partial 4 While the display page showing the Reset Total is displayed press the Reset key again for at least 1 second 5 The display screen again shows all the segments of the display followed by all the switched off segments and finally shows the display page where the reset Reset Total is shown It is possible to dispense displaying at the same time the dispensed partial the Flow Rate in Partial Unit minute as shown on the following display page 10 340 FLOW RATE Procedure for entering this mode wait for the meter to go to Standby meaning the display screen
2. Den Deckel Pos 7 und die Dichtung Pos 6 entfernen e Die ovalen Zahnr der entfernen e Reinigung vomehmen Dazu eine B rste oder einen spitzen Gegenstand verwenden wie z B einen kleinen Schraubenzieher Achtgeben dass der K rper und die Zahnr der nicht besch digt werden F r die Wiedermontage die Schritte in umgekehrter Reihenfolge durchf hren ACHTUNG Die Zahnr der wieder montieren wobei die nebenstehende Montageskizze zu beachten ist Fed ACHTUNG ee I Nur eines der 2 modular gepaarten Zahnr der ist mit Magneten OM ausgestattet Die Position des Magnetzahnrades muss der ill Abbildung entsprechen Das zweite Zahnrad ohne Magneten einsetzen wobei die Achse hinsichtlich des ersten Zahnrads mehr als 90 betragen muss 3 Filterreinigung Die Reinigung des Filters hat mit einer H ufigkeit zu erfolgen die je nach den in der gef rderten Fl ssigkeit enthaltenen Unreinigkeiten festgelegt wird Zur Durchf hrung dieses Vorgangs muss man das Instrument von der Leitung an der es angebracht ist entfernen weil sich der Filter zwischen dem Literz hlerk rper und dem Flansch zur Verbindung mit dem Schlauch befindet ACHTUNG Stets sicherstellen dass die Fl ssigkeit aus dem Literz hler entfernt wurde bevor die Reinigung vorgenommen wird Zur Filterreinigung wie folgt vorgehen mit Bezug auf die Positionen der Explosionszeichnungen Zum Zugang zur Filterscheibe von K600 3
3. Die Version PULSER ist ein Pulsgeber Reed Relais der die durch die Zahnraderrotation erzeugten Magnetfeldanderungen in elektrische Impulse verwandelt die an einen externen Empf nger gesandt werden der laut beiliegendem Plan anzuschlie en ist Der Pulser ben tigt keine unabh ngige Stromspeisung weil er direkt durch die Verbindung mit dem Empf nger gespeist wird Der abgegebene Impuls ist eine durch die Spannungs nderung erzeugte Rechteckwelle die sich so darstellen l sst V 0 IMPULS Die Eichung des Instruments erfolgt durch den extemen Impulsempf nger A M kammer Die Messkammer befindet sich im unteren Teil des Ger tes Ist mit Anschl ssen zur Anbringung von Gewindeflanschen am Ein und ausgang ausgestattet Der Deckel im unteren Bereich erm glicht den Zugriff auf den Messmechanismus bei ggf notwendigen Reinigungsarbeiten In der Messkammer befinden sich ovale Zahnr der die bei der Rotation elektrische Impulse erzeugen die von der elektronischen Karte mit Mikroprozessor verarbeitet werden Durch Anwendung eines zweckdienlichen Eichfaktors sprich eines jedem Impuls zugeordneten Gewichts verwandelt der Mikroprozessor der sich bei den Versionen Meter an Bord befindet und bei den Versionen Pulser entfernt liegt die durch die Rotation erzeugten Impulse in Fl ssigkeitsvolumen die in den vorbestimmten Ma einheiten ausgedr ckt und in den Teilwert und Gesamtwertregistern des Fl ssigkristalldisplays
4. FIELD 9 86 Dieser Vorgang ist besonders hilfreich um einen Durchschnittsfehler zu korrigieren der aufgrund vieler durchgef hrter Abgaben erhalten werden kann Wenn der normale METER Betrieb einen durchschnittichen Prozentfehler aufweist kann dieser korrigiert werden indem der momentan verwendete Kalibrierfaktor um denselben Prozentwert berichtigt wird In diesem Fall ist die prozentuale Korrektur des USER K FACTOR vom Bediener auf die folgende Art zu berechnen 100 E Neuer Kalibrierfaktor Alter Kalibrierfaktor x Beispiel Aufgetretener Prozentfehler E 0 9 Aktueller Kalibrierfaktor 1 000 Neuer USER K FACTOR 1 000 100 0 9 100 1 000 100 0 9 100 1 009 Wenn der Literz hler weniger als den reale Abgabewert anzeigt Negativfehler muss der neue Kalibrierfaktor gr er als der alte sein wie das Beispiel zeigt Umgekehrt wenn der Literz hler mehr als den realen Abgabewert angibt Positivfehler OPERATION DISPAY KONFIGURATION ws amp TOTAL METER im Normalzustand nicht beim Z hlen LANGES DR CKEN DER CAL TASTE Das METER tritt in Kalibriermodus und es wird anstelle der Teilmenge der verwendete Kalibrierfaktor angezeigt Die Anzeigen Fact oder USER geben an welcher der beiden Faktoren Benutzer oder Hersteller derzeit verwendet wird LANGES DR CKEN DER RESET TASTE Das METER zeigt die CAL Anzeige und die nullbare Gesamtmenge steht auf Null
5. NUR VERSION METER D 1 Definitionen Kalibrierfaktor oder K Factor dies ist der Multiplikationsfaktor den das System den empfangenen Elektroimpulsen zuweist um sie in Einheiten der gemessenen Flussigkeit zu verwandeln Factory K Factor Bei der Herstellung eingestellter vorbesetzter default Kalibrierfaktor Er ist gleich 1 000 Dieser Kalibrierfaktor garantiert h chste Genauigkeit bei den folgenden Benutzungsbedingungen Version f r l Fluid Motor l Typ SAE10W40 Temperatur 20 C Durchlaufmenge 6 60 Liter Min Version f r Diesel Fluid Motor l Typ SAE10W40 Temperatur 20 C Durchlaufmenge 6 60 Liter Min Auch nach eventuell vom Benutzer durchgef hrten nderungen kann mit einer einfachen Prozedur der vorbesetzte Kalibrierfaktor wiederhergestellt werden User K Factor Kalibrierfaktor der vom Benutzer an seine Bed rfnisse angepasst d h durch eine Kalibrierung ver ndert wurde D 2 Warum kalibrieren Das K600 METER wird mit einer vom Hersteller durchgef hrten Einstellung geliefert die eine genaue Messung bei den meisten Betriebsbedingungen garantiert Dennoch kann bei Extrembetrieb wie z B bei Fl ssigkeiten mit einer Viskosit t die nahe den zul ssigen Grenzwerten liegt wie Antifreeze mit geringer Viskosit t oder l mit hoher Viskosit t f r Getriebegeh use e bei extremen Durchlaufmengen die nahe am zugel ssigen oberen oder unteren Grenzwert liegen Es kann eine Eichung am Aufstellungso
6. LCD angezeigt werden AlleLiterzahler K600 2 3 verlassen das Werk miteinem Eichfaktor genannt FACTORY KFACTOR derentsprechend des verwendeten Fluids Diesel oder l vom Typ SAE10 W40 eingestellt ist um optimale Messleistungen zu erlangen Die Eichungseinstellungen lassen sich anhand den Anweisungen dieser Betriebsanleitung ndem aber es besteht jederzeit die M glichkeit auf die im Werk eingestellte Eichung zur ckzukehren DEUTSCH B INSTALLATION K600 METER oder PULSER haben je nach dem Fluid f r das sie geeicht wurden einen geraden Gewindeeingang und Ausgang 1 Inch oder Inch Geeignet zur station ren Anbringung an einer Leitung Sicherstellen dass die Schraubanschl sse nicht mitdem Inneren der Messkammer in Konflikt geraten und ein Blockieren der Zahnr der verursachen eine Kegelverbindungen verwenden die den Literz hlerk rper oder den Anschlussflansch besch digen k nnten Nur die Version Pulser ist mit Hilfe von 2 Kabeln unter Einhaltung der auf dem Schaltplan angegebenen elektrischen Merkmale anzuschliessen WICHTIG BEI DER MONTAGE DEN FILTER AN DER SAUGSEITE PLATZIEREN OUT H chststrom 100 mA H chstspannung 28 Vac dc H chstlast 3W Type out put clean contact open collector TAGLICHER EINSATZ 1 Version Pulser Der Literz hler k600 3 Version Pulser bedarf wenn er richtig mit dem Impulsempf nger verbunden ist keiner Ein und ausschaltun
7. Ma einheiten umgestellt Durch die Ver nderung der Ma einheit muss KEINE neue Kalibrierung vorgenommen werden F WARTUN Das METER wurde so konzipiert das eine minimale Wartung notwendig ist Die einzig notwendigen Wartungsarbeiten sind e Der Austausch der Batterien ist erforderlich wenn diese ersch pft sind nur bei den Versionen Meter Reinigung der Messkammer dies kann durch die Besonderheiten der abgegebenen Fl ssigkeiten oder durch das Eindringen von festen Teilchen aufgrund mangelhafter Filtration notwendig werden 1 Auswechseln der Batterien Das METER wird mit zwei 1 5 Volt Alkaline Batterien N geliefert Das METER ist mit zwei Alarmstufen zur Anzeige des niedrigen Batterieladezustands versehen 1 Wenn die Batterieladung unter die 1 Stufe absinkt erscheint auf dem LDC die station re Anzeige des Batteriezeichens eTa In diesem Zustand l uft der METER Betrieb korrekt weiter aber der Benutzer wird emia Gu durch das Symbol darauf hingewiesen dass die Batterien ausgewechselt werden mussen 2 Wenn das METER weiterhin mit den alten Batterien verwendet wird wird die zweite Alarmstufe erreicht und der Betrieb unterbunden In diesem Zustand und es ist nichts anderes auf dem Display sichtbar ACHTUNG Die entladenen Batterien nicht einfach wegwerfen Es sind die ortlichen Bestimmungen zu threr Entsorgung zu beachten Zum Auswechseln der Batterien ist wie folgt vorzugehen Verweis auf die Position der E
8. generated by the fluid volume rotation expressed in the set units of measurement displayed on the partial and total registers of the LCD All K600 2 3 meters are factory set with a calibration factor called FACTORY K FACTOR which is set according to the used fluid diesel fuel or oil of SAE10 W40 type for optimal measurement performance Calibration settings can be changed following the instructions in this manual but you can return to the factory calibration at any time B INSTALLATION gt K600 METER or PULSER features a 1 inch or 3 4inch inlet and outlet depending on the fluid for which they were calibrated threaded and perpendicular It is designed for fixed in line installation Make sure the threaded connections do not interfere with the inside of the measuring chamber causing the gears to seize Do not use any conical connections which may damage the meter body or the connection flange Only the Pulser version must be connected by means of 2 cables according to the electrical features in the diagram IMPORTANT CARRY OUT INSTALLATION BY PLACING THE SUCTION FILTER OUT REED BULB Max Current 100 mA Max Voltage 28 Vac dc Max Load 3W Type output clean contact open collector _C 4 PULSER VERSION _ The pulser version of K600 3 meter when properly connected to the pulse receiver does not need any start stop operation _C2 METER VERSION _ K600 METE
9. neue Kalibrierung vorgenommen werden D 3 1 Wi rein llen Her Anzeige des aktuellen Kalibrierfaktors und ggf llerfaktor Durch Dr cken der CAL Taste im Standby Status wird der derzeit verwendete Kalibrierfaktor angezeigt Cal Es k nnen zwei F lle auftreten a Wenn nie eine Kalibrierung vorgenommen wurde oder nach einer Kalibrierung wieder der Wert des Herstellers eingestellt wurde erscheint folgende Anzeige Die Schrift Fact Abk rzung f r factory weist darauf hin dass der Kalibrierfaktor des Herstellers verwendet wird b Wenn vom Benutzer Kalibrierungen durchgef hrt wurden wird der momentan verwendete Kalibrierwert angezeigt in unserem Beispiel 0 998 Die Schrift user weist darauf hin dass der verwendete Kalibrierfaktor vom Benutzer eingegeben wurde LEGENDE R R RESET long RESET court Das nebenstehende Flussdiagramm zeigt die zusammenh ngende Logik der R verschiedenen Anzeigen auf C C CALlong In diesem Zustand kann mit der RESET c CAL court Taste vom User zum Factory Faktor Time Out bergegangen werden Zur Best tigung der Kalibrierfaktor Wahl kurz die CAL Taste dr cken w hrend User oder Fact angezeigt ist 12 345 ca USER Nach dem Neustart verwendet der Literzahler den soeben bestatigten Kalibrierfaktor ACHTUNG In dem Moment in dem der Faktor des Herstellers bestatigt wird wird der alte Faktor des Benutzers aus dem Speicher geloscht STAND
10. of K600 Slide out the filter pos 9 Clean the filter with compressed air Carry out the reverse procedure to reassemble the filter ENGLISH Problem Possible Cause Remedial Action Check battery contacts check the K FACTOR The meter works below minimum Increase the flow rate until an been achieved The meter does not count but Possible electronic board Contact your dealer the flow rate is correct problems 2 Mechani Possible Cause Remedial Action Reduced or zero flow rate Gears blocked Clean the measuring chamber The meter does not count but the Incorrect installation of gears after Repeat the reassembly flow rate is correct cleaning procedure Inaccuracy Incorrect calibration of pulser version Calibrate the device with the pulse receiver working flow rate outside the flow reduce or increase the flow LCD no indications Bad battery contact Not enough measurement precision I malfunction rate range rate to return to the indicated flow rate range High loss of head dirty filter Clean the filter Braked gears clean the measuring chamber It does not count Wrong gear installation check the position of the gear with magnet faulty bulb change the bulb gg TFowraterange om oo msn Peursingpressure f eer fo lt i o Loss of Head at maximum flow bars 0 3 0 3 rate SAE 10W 40 20 C diesel fuel 20 C competes ai Batteries 2x1 5 2515 Volt Volt Battery Life expect
11. shows Total only quickly press the CAL key Start dispensing The flow rate is updated every 0 7 seconds Consequently the display could be relatively unstable at lower flow rates The higher the flow rate the more stable the displayed value WARNING The flow rate is measured with reference to the unit of measurement of the Partial For this reason in case of the unit of measurement of the Partial and Total being different as in the example shown below it should be remembered that the indicated flow rate relates to the unit of measurement of the partial In the example shown the flow rate is expressed in Qts min fan FLOW RATE s The word Gal remaining alongside the flow rate refers to the register of the Totals Reset or NON Reset which are again displayed when exiting from the flow rate reading mode To return to Normal mode press the CAL key again If one of the two keys RESET or CAL is accidentally pressed during the count this will have no effect Warning Even though in this mode they are not displayed both the Reset Total and the General Total Total increase Their value can be checked after dispensing has terminated returning to Normal mode by quickly pressing CAL To reset the Partial Register finish dispensing and wait for the meter to show a ee Flow Rate of 0 0 as indicated in the illustration FLOW RATE then quickly press RESET Unlike Normal mode in
12. the lower cover pos 7 e Remove the cover pos 7 and the seal pos 6 e Remove the oval gears Clean where necessary For this operation use a brush or pointed object such as a small screwdriver Be careful not to damage the body or the gears e To reassemble the instrument perform the operations in the opposite sequence ATTENTION Perform the assembly diagram to reassemble the gears ATTENTION Only one of the two gears modularly coupled as shown in the picture aside features magnets Observe the position of the gear with magnets as shown in the figure Fit the second gear without magnets with axis greater than 90 compared to the first gear 4 3 Cleaning the filter The filter cleaning interval is to be defined depending on the impurities contained in the fluid To perform this operation remove the device from the line on which it is installed as the filter is placed between the meter body and tube connection flange ATTENTION Always make sure that the liquid has drained from the meter before cleaning To clean the filter proceed as follows with reference to the exploded diagram positions To access the filtering disk of the K600 3 loosen the 2 fixing screws of the connection flange at the inlet Remove both flanges if it is necessary for the system Remove the meter from the line being careful to remove also the gaskets between the flanges and threaded connections
13. this case during reset you do not pass through the stages where the display segments are first lit up and then switched off but rather the reset partial register is immediately displayed D 1 Definiti Calibration factor or K Factor this is the multiplication factor applied by the system to the electrical pulses received to transform these into measured fluid units Factory K Factor Factory set default factor It is equal to 1 000 This calibration factor ensures utmost precision in the following operating conditions version for oil Fluid motor oil type SAE10W40 Temperature 20 C Flow rate 6 60 litres min version for diesel fuel Fluid motor oil type SAE10W40 Temperature 20 C Flow rate 6 60 litres min Even after any changes have been made by the user the factory K factor can be restored by means of a simple procedure User K Factor Customized calibration factor meaning modified by calibration _D2 Why calibrate 5 _ K600 METER is supplied with a factory calibration that ensures precise measuring in most operating conditions Nevertheless when operating close to extreme conditions such as for instance e with fluids close to acceptable range extremes such as low viscosity antifreeze or high viscosity oils for gearboxes in extreme flow rate conditions close to minimum or maximum acceptable values on the spot calibration may be required to suit the real conditions in which the meter is required to opera
14. BY BY zum L Dieser Vorgang sieht die Abgabe der Fl ssigkeit in einen Messbeh lter unter realen Betriebsbedingungen vor Durchflussmenge Viskosit t usw die genauestens einzuhalten sind ACHTUNG F r eine korrekte Kalibrierung des METERS sind die folgenden Punkte zu beachten e Die Anlage vollst ndig entl ften bevor die Kalibrierung durchgef hrt wird Einen Eichbeh lter von mindestens 5 Liter Fassungsverm gen verwenden der eine genaue Messmarkierung aufweist e Die Abgabe zur Kalibrierung bei konstanter Durchflussmenge durchf hren wie sie dem normalen Betrieb entspricht bis der Beh lter voll ist e Die Durchflussmenge nicht verringern wenn die Mass Skala des Beh lters in der Endphase der Abgabe beinahe erreicht ist die richtige Technik in der Endphase der Beh lterf llung besteht darin kurze Nachf llsch be bei normaler Betriebsdurchflussmenge vorzunehmen e Nach erfolgter Abgabe einige Minuten warten um sicherzustellen dass eventuell entstandene Luftblasen aus dem Beh lter entfernt wurden Den richtigen Wert erst nach Abschluss dieser Phase ablesen denn w hrenddessen kann der Stand im Beh lter noch absinken Den nachfolgend angef hrten Vorgang korrekt durchf hren DEUTSCH ra TOTAL METER im Normalzustand nicht beim Zahlen LANGES DRUCKEN DER CAL TASTE Das METER tritt in Kalibriermodus zeigt die Schrift CAL und zeigt anstelle der Gesamtmenge den verwendeten Kalibrierfaktor an D
15. Das METER ist bereit die Kalibrierung mittels Abgabe durchzuf hren LANGES DR CKEN DER RESET TASTE Direkte nderung des Kalibrierfaktors Es erscheint die Schrift Direct und der derzeit verwendete Kalibrierfaktor Links unten auf dem Display erscheint ein Pfeil der nach oben oder unten zeigt und die Richtung angibt in die der angezeigte Wert ver ndert wird Erh hen oder Vermindern wenn die Operationen 5 oder 6 durchgef hrt werden KURZES DR CKEN DER RESET TASTE Richtungswechsel des Pfeils Die Operation kann wiederholt werden um die Pfeilrichtung zu wechseln KURZES LANGES DR CKEN DER CAL TASTE Der angegebene Wert ndert sich in die vom Pfeil definierte Richtung eine Einheit f r jeden kurzen Druck der CAL Taste kontinuierlich wenn die CAL Taste gedr ckt gehalten wird Die Geschwindigkeit mit der der Wert erh ht wird erh ht sich wenn die Taste gedr ckt gehalten wird Wenn der gew nschte Wert berschritten wird den Vorgang ab Punkt 5 wiederholen 5 LANGES DR CKEN DER RESET TASTE Das METER wird informiert dass der Kalibriervorgang beendet ist Vor Durchf hrung dieser Operation sicherstellen dass der angezeigte Wert dem gew nschten Wert entspricht KEINE OPERATION Nach erfolgter Berechnung wird der neue USER K FACTOR f r einige Sekunden angezeigt dann wird der Neustartvorgang wiederholt um schlie lich den Standby Status zu erlangen ACHTUNG Ab diesem Moment wird der angezeigte Wert de
16. ENGLISH ENGLISH ENGLISH A HOW K600 3 WORKS GENERAL A 1 Meter Version A2 Pulser Version A3 Measuring Chamber B INSTALLATION C DAILY USE C 1 Pulser Version C2 Meter Version C 2 1 Dispensing in Normal mode C22 Partial reset C 2 3 Resetting the Reset Total C 2 4 Dispensing in Flow Rate Mode C25 Partial reset D CALIBRATION ONLY METER VERSIONS D 1 Definitions D 2 Why calibrate D3 Calibration procedure D 3 1 Display of Current Calibration Factor and Restoring Factory Factor D 3 2 In field Calibration D 3 2 1 In field calibration procedure D 3 3 Direct modification of K factor E METER CONFIGURATION F MAINTENANCE G MALFUNCTIONS G 1 Electronic malfunctions G 2 Mechanical malfunctions H TECHNICAL SPECIFICATIONS A ____HOW K600 3 WORKS GENERAL gt _ _ K600 meter and pulser versions represents a family of meters developed to satisfy a wide range of requirements for the control measurement dispensing and transfer of lubricating oils and fuels Its measurement principle is based on elliptical gears that provide high accuracy over a wide range of flow rates together with reduced loss of head The fluid passing through the instrument turns the gears whose rotation transfers constant fluid units The exact measurement of the fluid dispensed is carried out by counting the rotations of the gears and thus the fluid units transferred The magnetic coupling consisting of magnets installed in the gears and a magnetic swi
17. G CHAMBER 1 LCD display a a a a Qrs The LCD of the METER features two 1 9 numerical registers and various indications r E r ee u a L displayed to the user only when the M al J Li applicable function so requires 5 7 3 4 5 6 Key 1 Partial register 5 figures with moving comma 0 000 99999 indicating volume dispensed from when the RESET button was last pressed 2 Indication of battery charge 3 Indication of calibration mode 4 Totals register 6 figures with moving comma 0 0 999999 x10 x100 that can indicate two ypes of Total 4 1 General Total that cannot be reset TOTAL 4 2 Resettable total Reset TOTAL 5 Indication of total multiplication factor x10 x100 6 Indication of type of total TOTAL Reset TOTAL 7 Indication of unit of measurement of Totals L Litres Gal Gallons 8 Indication of Flow Rate 9 Indication of unit of measurement of Partial Qts Quarts Pts Pints L Litres Gal Gallons 2 User Buttons The meter features two buttons RESET and CAL which individually perform two main functions and together other secondary functions The main functions performed are for the RESET key resetting the partial register and Reset Total for the CAL key entering instrument calibration mode Used together the two keys permit entering configuration mode where the desired unit of measurement can be set 3 Battery Housing The METER is powered by two sta
18. R is delivered ready for use No commissioning operations are required even after long storage periods The only operations that need to be done for daily use are Partial and or Resettable Total register resetting Below are the two typical normal operation displays One display page shows the partial and Reset Total registers The other shows the partial and general total Switchover from Reset Total to general total display is automatic and tied to phases and times that are factory set and cannot be changed by the user 3 Q PARTIAL register Q TS TS es ETHS a RESET TOTAL GENERAL 124 total WAL erent ae 23 rom Gau register Total The Partial register positioned in the top part of the display indicates the quantity dispensed since the RESET key was last pressed The Resettable Total register positioned in the lower part of the display indicates the quantity dispensed since the last ResettableTotal resetting The RESET Total cannot be reset until the Partial has been reset while vice versa the Partial can always be reset without resetting the RESET Total The unit of measurement of the two Totals can be the same as the Partial or else different according to the factory or user settings The General TOTAL register Total can never be reset by the user It continues to rise for the entire operating life of the meter The register of the two totals Reset Total and Total share the same area and digits of the display For this reas
19. TRETIEN PROBLEMES DE FONCTIONNEMENT G 1 Probl mes de fonctionnement lectroniques G 2 Probl mes de fonctionnement m caniques H DONNEES TECHNIQUES Tn m A KENNTNIS VON K ALLGEMEIN K600 Version Meter und Pulser stellt eine Serie von Literz hlern dar die entwickelt wurden um die verschiedensten Anspr che hinsichtlich Kontrolle und Messung w hrend der Abgabe und Umf llung von Schmier len und Kraftstoffen zu erf llen Dank des Mess Systems mit ovalen Zahnr dern kann in verschiedenen Durchflussbereichen eine hohe Pr zision bei geringem Str mungsverlust erreicht werden Die Fl ssigkeit durchl uft das Ger t und bringt dabei die Zahnr der zum Rotieren diese bertragen beim Drehen Fl ssigkeitseinheiten von konstantem Volumen Die genaue Messung der abgegebenen Fl ssigkeit wird vorgenommen indem die von den Zahnr dern durchgef hrten Drehungen und somit die bertragenen Fl ssigkeitseinheiten gez hlt werden Die magnetische Kopplung die zwischen den in den Zahnr dern eingebauten Magneten und einem au erhalb der Messkammer befindlichen Magnetschalter besteht garantiert die Versiegelung der Messkammer und die bertragung der Impulse die durch die Rotation der Zahnr der erzeugt werden an einen Mikroprozessor Der Literz hlerk rper besteht aus druckgegossenem Aluminium und verf gt ber Anschl sse zur Montage von Gewindeflanschen zwecks Anpassung an jede Art von Leitung An der Einlassm ndung ist eine Filtersche
20. con starts to flash and is the only one to remain visible on the LCD ATTENTION Do not discard the old batteries into the environment Refer to local disposal regulations To change the batteries with reference to the spare parts list positions proceed as follows e Press RESET to update all the totals e Unscrew the battery cap pos 8 e Remove the old batteries e Place the new batteries in the same position as the old ones making sure the e positive pole is positioned as indicated on the cover pos 9 Re tighten the battery cap making sure the seal pos 1 are correctly positioned The METER will switch on automatically and normal operation can be resumed The METER will display the same Reset Total the same Total and the same Partial indicated before the batteries were changed After changing the batteries and subsequently every time there is a power break the METER will start again and use the same calibration factor used when the break occurred The meter does not therefore need calibrating again 2 Cleaning the MEASURING CHAMBER The K600 measuring chamber can be cleaned without removing the instrument from the line on which it is fitted Make sure the gears are tuming freely before closing the cover ATTENTION Always make sure that the liquid has drained from the meter before cleaning To clean the chamber proceed as follows with reference to the exploded diagram positions e Loosen the four retention screws of
21. dem auf die Taste RESET gedr ckt wurde abgegebene Volumen an 2 Anzeige des Ladezustands der Batterie 3 Anzeige der Kalibriermodalit t 4 Register der Gesamtmengen 6 Ziffern mit Gleitkomma 0 0 999999 x10 x100 das zwei Arten von Gesamtmenge darstellen kann 4 1 Nicht nullbare Gesamtmenge TOTAL 4 2 Nullbare Gesamtmenge Reset TOTAL 5 Anzeige des Multiplikationsfaktors der Gesamtmengen x10 x100 6 Anzeige des Gesamtmengentyps TOTAL Reset TOTAL T Anzeige der Gesamtmengen Ma einheit L Liter Gal Gallonen 8 Flow Rate Anzeige 9 Anzeige der Teilmengen Ma einheit Qts Viertel Pts Pints L Liter Gal Gallonen 2 Anwenderdruckkn pfe Das METER ist mit zwei Drucktasten RESET und CAL ausgestattet die jeder f r sich zwei Hauptfunktionen ausf hren und in Kombination andere Nebenfunktionen bernehmen Hauptfunktionen RESET Taste das Nullen des Teilmengen Registers und des nullbaren Gesamtmengen Registers Reset Total CAL Taste Aufrufen des Kalibriermodus des Ger tes In Kombination erm glichen die beiden Tasten das Aufrufen des Konfigurationsmodus Configuration Mode in dem die gew nschte Ma einheit eingegeben werden kann 3 Sitz der Batterie Das METER wird von zwei 1 5 V Standard Batterien N gespeist Der Sitz der Batterien wird durch einen dichten Schraubdeckel verschlossen der sich leicht ffnen l t um ein schnelles Austauschen der Batterien zu erm glichen A 2 Version Pulser
22. die 2 Befestigungsschrauben des am Eingang angebrachten Verbindungsflansches abschrauben Wenn es die Anlage erforderlich macht beide Flanschen abmontieren Den Literz hler von der Leitung entfemen und dabei darauf achten dass auch die zwischen den Flanschen und den Schraubverbindungen von K600 abgebrachten Dichtungen entfernt werden Filter herausziehen Pos 9 Den Filter mit Druckluft reinigen F r die Wiedermontage des Filters die Schritte in umgekehrter Reihenfolge durchf hren DEUTSCH G BETRIEBSSTORUNGEN 1 Elektroni he Betri rungen LCD Keine Anzeige Wackelkontakt der Batterien Batteriekontakte berpr fen Ungen gende Unkorrekter KFACTOR K FACTOR berpr fen siehe Paragraph H Messgenauigkeit Der Literz hler l uft unterhalb Durchlaufmenge erh hen bis der minimal zul ssigen eine akzeptable Durchlaufmenge Durchlaufmenge erreicht ist M gliche Probleme bei der H ndler kontaktieren elektronischen Karte Der Literz hler misst nicht aber die Durchfussmenge ist normal St rung Possible Cause Remedial Action Verminderte oder gar keine Zahnr der blockiert Durchlaufmenge Der Literz hler misst nicht Unkorrekte Installation der Die Schritte zum Einbauen Zahnr der nach der Reinigung wiederholen aber die Durchfussmenge ist normal nicht korrekt Impulsempf nger eichenr Betriebsf rderleistung au erhalb Die F rderleistung verringern des F rderleistungsbereichs oder erh hen bi
23. ds depending on the correction to be made During this operation the arrow disappears but the CAL indication remains If this operation is performed after operation 5 without changing the indicated value the USER K FACTOR would be the same as the FACTORY K FACTOR thus it is ignored NO OPERATION Atthe end ofthe calculation the new USER K FACTOR is shown for a few seconds after which the restart cycle is repeated to finally achieve standby condition Cal FIELD IMPORTANT From now on the indicated factor will become the calibration factor used by the meter and will continue to remain such even after a battery change NO OPERATION METER stores the new calibration factor and is ready for dispensing applying the newly defined USER K FACTOR ca IS Gx This procedure is especially useful to correct a mean error obtainable on the basis of several performed dispensing operations If normal METER operation shows a mean percentage error this can be corrected by applying to the currently used calibration factor a correction of the same percentage In this case the percentage correction of the USER K FACTOR must be calculated by the operator in the following way 100 E New cal Factor Old cal Factor X CB Example Error percentage found E 0 9 CURRENT calibration factor 1 000 New USER K FACTOR 1 000 100 0 9 100 1 000 100 0 9 100 1 009 If the meter indicates less than the real dispensed valu
24. e negative error the new calibration factor must be higher than the old one as shown in the example The opposite applies if the meter shows more than the real dispensed value positive error OPERATION DISPAY CONFIGURATION NONE METER innormal mode not in counting mode LONG CAL KEY KEYING METER enters calibration mode shows CAL and displays the calibration factor being used instead of the partial The words Fact and User indicate which of the two factors factory or user is currently being used LONG RESET KEY KEYING The METER shows CAL and the zero partial total METER is ready to perform in field calibration by dispensing see previous paragraph LONG RESET KEY KEYING We now go on to Direct change of the calibration factor the word Direct appears together with the Currently Used calibration factor In the bottom left part of the display an arrow appears upwards or downwards defining the direction increase or decrease of change of the displayed value when subsequent operations 5 or 6 are performed SHORT RESET KEY KEYING Changes the direction of the arrow The operation can be repeated to alternate the direction of the arrow SHORT LONG CAL KEY KEYING The indicated value changes in the direction indicated by the arrow one unit for every short CAL key keying continually if the CAL key is kept pressed The speed increase rises by keeping the key pressed If the desired value is
25. ed 18 36 18 36 months months DECLARATION OF CONFORMITY Complies with the directive 89 336 EEC electromagnetic compatibility and subsequent amendments PIUSI S p A 46029 Suzzara Mantova Italy declares that the following model of meter K600 to which this declaration refers conforms to the following applicable regulations European regulations EN 61000 6 1 EN 61000 6 3 EN 55014 1 2000 EN55014 2 97 O Vou Suzzara 01 01 06 the President Otto Varini MO147ENDE Rev 1 CALIBRATION USE AND MAINTENANCE MANUAL ENGLISH BETRIEBS WARTUNGS UND EICHUNGSANLEITUNG DEUTSCH FLUID HANDLING TECHNOLOGY PIUSI S p A 46029 Suzzara Mantova Italy Bulletin M0147 Rev 1 DEUTSCH A CONNAITRE K600 3 GENERALITES A 1 VERSION METER A2 VERSION PULSER A 3 CHAMBRE DE MESURE B INSTALLATION C UTILISATION QUOTIDIENNE C 1 VERSION PULSER CZ VERSION METER C 2 1 Distribution dans le mode Normal Normal Mode C 2 2 Mise a zero du Partiel C23 Mise a z ro du Reset Total Total avec z rotage C 2 4 Distribution avec affichage du Debit Instantane Flow Rate Mode C25 Mise a zero du Partiel D ETALONNAGE UNIQUEMENT VERSIONS METER D 1 D finitions D 2 Pourquoi talonner D 3 Modes d talonnage D 3 1 Afficher le facteur d talonnage courant et retoumer au facteur d usine D 3 2 Etalonner sur place D 3 2 1 Comment talonner sur place D 3 3 Modifier le facteur K CONFIGURATION DU COMPTE LITRES EN
26. enge eine unterschiedliche Ma einheit wie im nachfolgend angef hrten Beispiel angezeigt wird ist somit darauf zu achten dass die angezeigte Durchflussmenge in der Ma einheit der Teilmenge angegeben wird Im angef hrten Beispiel ist die Durchflussmenge in Qts Min angegeben ean FLOW RATE 125 Gal Die Schrift Gal neben der Flow Rate bezieht sich auf das Register der nullbaren oder NICHT nullbaren Gesamtmengen die erneut angezeigt werden wenn der Anzeigemodus der Durchflussmenge wieder verlassen wird Um zum Normalmodus zur ckzukehren erneut die CAL Taste dr cken Das ungewollte Dr cken der RESET oder CAL Taste w hrend der Z hlung hat keinerlei Auswirkungen Achtung Auch wenn in diesem Modus die nullbare Reset Total und die absolute Gesamtmenge Total nicht angezeigt werden erh ht sich ihr Wert dennoch Dieser kann nach erfolgter Abgabe berpr ft werden wenn im Normalmodus kurz die CAL Taste gedr ckt wird C 2 5 Nullen der Teilmenge Zum Nullen des Teilmengen Registers die Abgabe beenden abwarten bis das Meter eine Flow Rate von 0 0 anzeigt siehe Abb ree be FLOW RATE s und dann kurz die RESET Taste dr cken Im Gegensatz zum Normalmodus wird in diesem Fall wahrend der Nullstellung nicht die Phase durchlaufen in der alle Display Segmente erst ein und dann ausgeschaltet werden sondern es wird sofort das Register der genullten Teilmenge angezeigt D EICHUNG
27. exceeded repeat the operations from point 5 LONG RESET KEY KEYING The METER is informed that the calibration procedure is finished Before performing this operation make sure the indicated value is that required NO OPERATION At the end of the calculation the new USER K FACTOR is shown for a few seconds after which the restart cycle is repeated to finally achieve standby condition IMPORTANT From now on the indicated factor will become the calibration factor used by the meter and will continue to remain such even after a battery change NO OPERATION METER stores the new calibration factor and is ready for dispensing applying the newly defined USER K FACTOR ENGLISH E METER CONFIGURATION gt _ METER is fitted with a menu by which the user can select the main unit of measurement Quarts Qts Pints Pts Litres Lit Gallons Gal The combination between the unit of measurement of the Partial Register and that of the Totals is set according to the following table Combination no Unit of Measurement Unit of Measurement Partial Register Totals Register Lies Li Lires Li Gallons Gal Gallons Gal Quarts Qts Gallons Gal Pints Pts Gallons Gal To choose between the 4 available combinations Wait for the METER to go to Standby then press the CAL and RESET keys together Keep these pressed until the word UNIT appears on the screen together with the unit of measurement set at tha
28. g C 2 Version Meter Das K600 METER wird gebrauchsfertig geliefert Auch nach langen Lagerzeiten ist das Ger t sofort betriebsbereit Die einzigen Operationen die beim t glichen Gebrauch vorzunehmen sind ist die Nullung der Register von Teil und oder nullbarer Gesamtmenge Daraufhin werden die beiden Anzeigen des Normalbetriebs aufgerufen Die eine Anzeige beinhaltet die Teilmenge und die nullbare Gesamtmenge Reset Total Die andere Anzeige zeigt die Teilmenge und die absolute Gesamtmenge Der bergang von der nullbaren Gesamtmenge auf die absolute Gesamtmenge erfolgt automatisch und ist einer Zeitspanne unterworfen die bei der Herstellung festgelegt wurde und vom Benutzer nicht ver ndert werden kann 1 Q PARTIAL register 4 Q TS ic JHS e bt bt ER an GENERAL registerto 103 m Gar RESET TOTAL er 23 mu Ga register Total Das Register der Teilmenge im oberen Teil des Displays gibt die Menge an die seit der letzten Betatigung der RESET Taste abgegeben wurde Das Register der nullbaren Gesamtmenge Reset Total im unteren Teil des Displays gibt die Menge an die seit der Durchf hrung der letzten Nullstellung der nullbaren Gesamtmenge abgegeben wurde Es kann keine Nullstellung der Gesamtmenge Reset Total stattfinden wenn zuvor nicht die Teilmenge genullt wurde umgekehrt dagegen kann die Teilmenge jederzeit genullt werden ohne die Gesamtmenge Reset Total nullen zu m ssen Gesamtmengen und Teilmenge k nnen diese
29. h in die vom Pfeil definierte Richtung eine Einheit fur jeden kurzen Druck der CAL Taste kontinuierlich wenn die CAL Taste gedr ckt gehalten wird die ersten 5 Einheiten langsam danach schnell Ist der gew nschte Wert berschritten die Operation ab Punkt 6 wiederholen 6 LANGES DR CKEN DER RESET TASTE Das METER wird informiert dass der Kalibriervorgang beendet ist Bevor diese Operation durchgef hrt wird achtgeben dass der RICHTWERT mit dem ISTWERT bereinstimmt 9 6650 9 cal FACT Richtwert Istwert Das Meter berechnet den neuen USER K FACTOR Diese Berechnung kann einige Sekunden dauem abh ngig von der Korrektur die vorzunehmen ist W hrend dieses Vorgangs erlischt der Pfeil aber die Anzeige CAL bleibt bestehen Wird diese Operation nach Punkt 5 durchgef hrt ohne den angegebenen Wert zu ndern ist der USER K FACTOR gleich dem FACTORY K FAKTOR und wird somit ignoriert KEINE OPERATION Nach erfolgter Berechnung wird der neue USER K FACTOR f r einige Sekunden angezeigt dann wird der Neustartvorgang wiederholt um schlie lich den Standby Status zu erlangen ACHTUNG Ab diesem Moment wird der angezeigte Wert der neue Kalibrierfaktor der vom METER verwendet wird und bleibt dies auch nach einem Batteriewechsel KEINE OPERATION METER speichert den neuen Betriebseichfaktor und steht zur Abgabe mittels nogo amp Anwendung des soeben berechneten USER K FACTOR bereit TOTAL Cal 12345 Gar 9 860 Cal
30. ibe aus Edelstahlnetz angebracht die anhand Entfemung des an der Einlassseite angebrachten Flansches von aussen zug nglich ist A 1 VERSION METER Der Benutzer kann zwischen zwei verschiedenen Benutzungsmodalitaten ausw hlen Normal Mode Betrieb mit Anzeige der abgegebenen Teil und Gesamtmengen Flow Rate Mode Betrieb mit Anzeige der momentanen F rdermenge Flow Rate zus tzlich zu der abgegebenen Teilmenge Das METER ist mit einem nicht fl chtigen Speicher versehen so dass archivierte Abgabe Daten auch ohne Stromversorgung ber einen langen Zeitraum gespeichert bleiben LCD DISPLAY Hauptbestandteile CAL TASTE Die Mess Elektronik und das Fl ssigkristall Display LCD sind im oberen Teil des Literz hlers installiert von der nassen Mess Kammer isoliert und vom Aussenbereich durch einen Deckel versiegelt RESET TASTE SITZ DER BATTERIE FILTER MESS KAMMER 1 Fl ssigkristall Display LCD Das Fl ssigkristalldisplay des METERs ist mit zwei numerischen Registem und K x x 7 x Qrs verschiedenen Anzeigen ausgestattet 1 a a a u 9 die dem Benutzer nur dann angezeigt L werden wenn die momentane Funktion Va VAN m VAN Vax GaL dies erfordert 2 FLOW RATE RESET A A aa GAL 7 3 fal x100 L 4 5 6 Legende 1 Register der Teilmenge 5 Ziffern mit Gleitkomma 0 000 99999 zeigt das seit dem letzen Mal an
31. ie Angaben Fact und USER geben an welcher der beiden Faktoren Hersteller oder Benutzer momentan in Gebrauch ist LANGES DR CKEN DER RESET TASTE Das METER zeigt die CAL Anzeige und die nullbare Gesamtmenge steht auf Null Die Literme uhr ist zur Ausf hrung der Kalibrierung am aufgestellten Ger t bereit ABGABE IN DEN EICHBEH LER Ohne eine Taste zu dr cken die Abgabe in den Eichbeh lter beginnen A Die Abgabe kann beliebig unterbrochen und wiederaufgenommen werden Die Abgabe durchf hren bis die Fl ssigkeit die Mass Skala des Eichbeh lters erreicht Es ist nicht notwendig eine bestimmte Menge zu erreichen gt 9 86 Richtwert KURZES DR CKEN DER RESET TASTE Das METER wird informiert dass die Kalibrier Abgabe beendet ist Achtgeben dass die Abgabe vollst ndig abgeschlossen ist bevor dies geschieht Zur Kalibrierung des METERS muss der vom Z hlwerk der Teilmenge angegebene Wert Beispiel 9 800 auf den Istwert gebracht werden der vom Eichbeh lter angezeigt wird Unten links auf dem Display erscheint ein Pfeil der nach oben oder unten zeigt und die Richtung angibt in die der Wert vom USER K FACTOR ver ndert wird Erh hen oder Vermindem wenn die Operationen 6 oder 7 durchgef hrt werden KURZES DR CKEN DER RESET TASTE Richtungswechsel des Pfeils Dieser Vorgang kann beliebig oft wiederholt werden 0 888 Cal FIELD KURZES LANGES DRUCKEN DER CAL TASTE Der angegebene Wert andert sic
32. lbe oder unterschiedliche Ma einheiten aufweisen je nach Einstellung durch Hersteller oder Benutzer Das Register der absoluten Gesamtmenge Total kann vom Benutzer nicht genullt werden Es wird sich ber die gesamte Lebenszeit des Literz hlers stetig erh hen Die Register der beiden Gesamtmengen Reset Total und Total nehmen denselben Raum und dieselben Ziffem des Displays ein Aus diesem Grund sind die beiden Gesamtmengen nie zusammen sondem immer nur abwechselnd sichtbar Das Meter wurde so programmiert dass die eine oder andere Gesamtmenge in bestimmten Momenten angezeigt wird DER ALLGEMEINE GESAMTWERT TOTAL WIRD VON METER W HREND DER BETRIEBSART STANDBY ANGEZEIGT DER R CKSTELLBARE GESAMTWERT RESET TOTAL WIRD WIE FOLGT ANGEZEIGT F r kurze Zeit einige Sekunden nach einer Nullstellung der Teilmenge Bei der Fl ssigkeitsabgabe F r einige Sekunden nach erfolgter Fl ssigkeitsabgabe Die Erh hung erfolgt mit folgender Sequenz HINWEIS F r die Gesamtmengen stehen 6 Ziffern zur Verf gung zuz glich zwei Ikonen x10 x100 Die Erh hung erfolgt mit folgender Sequenz 0 0 99999 9 999999 100000 x 10 999999 x 10 100000 x 100 999999 x 100 21 A im Normalm Normal M Bei der Standard Abgabe werden w hrend der Z hlung gleichzeitig die abgegebene Teilmenge und die nullbare Gesamtmenge Reset Total angezeigt Das ungewollte Dr cken der RESET oder CAL Taste w hrend der Z hlung hat keinerlei Au
33. libration factor used A 19 Two cases can occur Cal USER a If no calibration has ever been performed or the factory setting has been restored after previous calibrations the following display page will appear The word Fact abbreviation for factory shows that the factory calibration factor is being used If on the other hand calibrations have been made by the user the display page will appear showing the currently used calibration factor in our example 0 998 The word user indicates a calibration factor set by the user is being used long RESET von RESET a SNe 234112 3 Ga In this condition the Reset key permits C C long CAL 12 345 cal USER The flow chart alongside shows the EGEND switchover logic from one display page to RR another R switching from User factor to Factory C factor To confirm the choice of calibration factor quickly press CAL while User or Fact are displayed short CAL Time Out After the restart cycle the meter uses the calibration factor that has just been confirmed IMPORTANT When the Factory Factor is confirmed the old User factor is deleted from the memory ie 9 234123 Ga This procedure calls for the fluid to be dispensed into a graduated sample container in real operating conditions flow rate viscosity etc requiring maximum precision ATTENTION For correct METER calibration it is most important to completely eli
34. minate air from the system before calibrating use a precise Sample Container with a capacity of not less than 5 litres featuring an accurate graduated indicator ensure calibration dispensing is done at a constant flow rate equivalent to that of normal use until the container is full not reduce the flow rate to reach the graduated area of the container during the final dispensing stage the correct method during the final stages of sample container filling consists in making short top ups at normal operation flow rate after dispensing wait a few minutes to make sure any air bubbles are eliminated from the sample container only read the Real value at the end of this stage during which the level in the container could drop Carefully follow the procedure indicated below ENGLISH am TOTAL METER in normal mode not in counting mode LONG CAL KEY KEYING The METER enters calibration mode shows lt lt CAL gt gt and displays the calibration factor in use instead of partial The words Fact and USER indicate which of the two factors factory or user is currently in use Important LONG RESET KEY KEYING The METER shows CAL and the zero partial total The meter is ready to perform in field calibration DISPENSING INTO SAMPLE CONTAINER Without pressing any button start dispensing into the sample container Abs Dispensing can be interrupted and started again at will Continue dispensing u
35. ndard type 1 5 V batteries size N The battery housing is closed by a threaded watertight cap that can be easily removed for quick battery change _A 2 PULSER VERSION gt The PULSER version is a pulse emitter reed bulb which translates the magnetic field variations generated by gear rotation into electric pulses to be sent to an external receiver The receiver is to be connected according to the enclosed diagram The pulser does not need any independent electric power supply as it is directly powered by the receiver connection The issued pulse type is represented by a square wave generated by the voltage variation see the following diagram V 0 PULSE The device calibration is carried out by means of the external pulse receiver _A 3 MEASURING CHAMBER ___ The measuring chamber is located in the lower part of the instrument It is fitted with connections for the installation of threaded flanges at inlet and outlet The cover on the bottom part provides access to the measurement mechanism for any cleaning operations Inside the measuring chamber are the oval gears which on turning generate electrical pulses which are processed by the microprocessor controlled electronic board By applying a suitable calibration factor meaning a weight associated with each pulse the microprocessor on board on meter versions and remote on pulser versions translates the pulses
36. ntil the level of the fluid in the sample container has reached the graduated area There is no need to reach a preset quantity Indicated value Real value SHORT RESET KEY KEYING The METER is informed that the calibration dispensing operation is finished Make sure dispensing is correctly finished before performing this operation To calibrate the METER the value indicated by the partial totaliser example 9 800 must be forced to the real value marked on the graduated sample container In the bottom left part of the display an arrow appears upwards and downwards that shows the direction increase or decrease of the USER K FACTOR value change when the operations 6 or 7 are performed SHORT RESET KEY KEYING Changes the direction of the arrow The operation can be repeated as many times as you wish SHORT LONG CAL KEY KEYING The indicated value changes in the direction indicated by the arrow 0 86a one unit for every short CAL key keying continually if the CAL key is kept pressed for the first 5 units slowly and then quickly If the desired value is exceeded repeat the operations from point 6 LONG RESET KEY KEYING The METER is informed that the calibration procedure is finished Before performing this operation make sure the INDICATED value is the same as the REAL value P 9 86 9 660 amp Cal FACT Indicated value Real value The METER calculates the new USER K FACTOR this calculation could require a few secon
37. on the two totals will never be visible at the same time but will always be displayed alternately The meter is programmed to show one or the other of the two totals at very precise times THE GENERAL TOTAL TOTAL IS SHOWN DURING METER STANDBY THE RESET TOTAL IS SHOWN At the end of a Partial reset for a certain time a few seconds During the entire dispensing stage For a few seconds after the end of dispensing Once this short time has expired Meter switches to standby and lower register display switches to General Total NOTE 6 digits are available for Totals plus two icons x 10 x100 The increment sequence is the following 100000 x 10 999999 x 10 100000 x 100 999999 x 100 6 24 Di ing in N This is default dispensing during which while the count is made the Partial and Reset Total are displayed at the same time Should one of the two keys RESET or CAL be accidentally pressed during counting this will have no effect A few seconds after dispensing has ended on the lower register the display switches from Resettable Total to General Total the word RESET above the word TOTAL disappears and the Reset Total is replaced by the General Total This situation is called STANDBY and remains stable until the user operates the meter again _C22 Partial reset en The Partial Register can be reset by pressing the RESET key when the meter is in Standby meaning when the display screen shows the word TOTAL
38. r neue Kalibrierfaktor der vom METER verwendet wird und bleibt dies auch nach einem Batteriewechsel KEINE OPERATION METER speichert den neuen Betriebseichfaktor und steht zur Abgabe mittels Anwendung des soeben berechneten USER K FACTOR bereit DEUTSCH E KONFIGURATION DES LITERZ HLERS METER verf gt ber ein Men mit dem der Nutzer die Hauptma einheit w hlen kann Viertel Qts Pints Pts Liter Lit Gallonen Gal Die Kombination zwischen den Ma einheiten des Teilwertregisters und des Gesamtwertregisters ist laut folgender Tabelle vorgegeben Ma einheit Teilmengen Register Gesamtmengen Register Liter Lit Liter Lit Ma einheit Kombinations Nr Zur Wahl einer der vier vorgeschlagenen Kombinationen jah 8 TOTAL Warten bis sich das METER in Standby Status IHSE Gal befindet dann gleichzeitig die Tasten CAL und RESET dr cken bis auf dem Display die Schrift UNIT und die in diesem Moment festgelegte Ma einheit erscheinen in unserem Beispiel Liter Liter Bei jedem kurzen Druck der RESET Taste werden nach und nach die verschiedenen Kombinationen der Ma einheiten aufgerufen wie nachfolgend gezeigt wird Durch langes Dr cken der CAL Taste werden die neuen Einstellungen abgespeichert und das METER ist nach Durchlauf des Startvorgangs bereit die Abgaben in den neuen Ma einheiten vorzunehmen ACHTUNG Die Register der nullbaren und absoluten Gesamtmenge werden automatisch in die neuen
39. rsatzteilliste e RESET dr cken um die Gesamtmengen auf den neusten Stand zu bringen e Den Batteriedeckel abschrauben Pos 8 e Die entladenen Batterien entfernen Die neuen Batterien anstelle der alten einsetzen dabei darauf achten dass der Pluspol so positioniert ist wie auf dem Deckel angezeigt Pos 1 e Den Batteriedeckel wieder festschrauben dabei darauf achten dass Dichtung Pos 7 und Feder Pos 9 wieder korrekt positioniert werden e Das METER schaltet sich automatisch ein und der normale Betrieb kann wieder aufgenommen werden Das METER zeigt dieselben Werte f r nullbare Gesamtmenge absolute Gesamtmenge und Teilmenge an wie vor dem Auswechseln der Batterien Nach dem Auswechseln der Batterien und nach jedem Stromausfall verwendet das METER denselben Kalibrierfaktor den es auch vor dem Ausfall verwendet hat Deshalb ist keine Neukalibrierung des Literz hlers notwendig 2 Reinigung der Messkammer Die Reinigung der Messkammer von K600 kann ohne Entfernung des Instruments von der Leitung an der es angebracht ist erfolgen Kontrollieren dass sich die Zahnr der frei drehen bevor der Deckel wieder verschlossen wird ACHTUNG Stets sicherstellen dass die Fl ssigkeit aus dem Literz hler entfernt wurde bevor die Reinigung vorgenommen wird Zur Kammerreinigung wie folgt vorgehen mit Bezug auf die Positionen der Explosionszeichnungen e Die vier Dichtungsschrauben des unteren Deckels abschrauben Pos 7
40. rt angebracht sein die unter den wirklichen Bedingungen bei denen Meter arbeiten muss durchgef hrt wird D Kalibrierm Das K600 METER erm glicht die Durchf hrung einer schnellen und genauen elektronischen Kalibrierung durch die nderung des Kalibrierfaktors K FACTOR Zur Kalibrierung des Ger tes k nnen zwei Prozeduren durchgef hrt werden 1 Kalibrierung bei Betriebssimulation bei der eine Fl ssigkeitsabgabe durchgef hrt wird 2 Direkte Kalibrierung die durch die Ver nderung des Kalibrierfaktors vorgenommen wird Es kann aus folgendem Grund Zugang zum Kalibrierprozess gew hrt werden durch l ngeres Dr cken der CAL Taste Anzeige des momentan verwendeten Kalibrierfaktors Wiedereinstellen des Kalibrierfaktors des Herstellers Factory K Factor nach einer Kalibrierung durch den Benutzer nderung des Kalibrierfaktors mittels einer der beiden zuvor genannten Vorg nge 1 Bei der Betriebsart Eichung haben die Anzeigen der abgegebenen Teilmenge und der Gesamtmenge je nach Phase des Eichungsverfahrens verschiedene Bedeutungen 2 Im Kalibriermodus kann das METER keine normalen Abgaben durchf hren 3 Im Kalibriermodus werden die Gesamtmengen nicht erh ht ACHTUNG Das METER ist mit einem nicht fliichtigen Speicher versehen so dass gespeicherte Kalibrierdaten und die abgegebene Gesamtmenge auch ohne Stromversorgung ber einen beliebig langen Zeitraum gespeichert bleiben Nach dem Auswechseln der Batterien muss keine
41. s Display seine normale Standby Anzeige aufweist nur die Gesamtmenge Total wird angezeigt 2 Kurz die RESET Taste dr cken 3 Die Messuhr beginnt die Nullungsprozedur der Teilmenge 4 W hrend das Display das Reset Total anzeigt emeut die RESET Taste f r mindestens eine Sekunde dr cken 5 Das Display zeigt emeut alle seine Segmente danach folgt die Phase in der alle Segmente ausgeschaltet sind um schlie lich zur Anzeige berzugehen auf der die genullte Gesamtmenge Reset Total angegeben wird C 2 4 Abgabe mit Anzeige des Momentdurchflusses Flow Rate Mode Es ist m glich Abgaben vorzunehmen bei der gleichzeitig folgende Anzeigen erscheinen Abgegebene Teilmenge Momentdurchfluss Flow Rate in Ma einheit der Teilmenge Min wie nachfolgend angezeigt wird Vorgehensweise um in diesen Modus zu gelangen Abwarten bis sich das Meter in Standby Zustand befindet d h bis das Display nur die Gesamtmenge anzeigt Kurz die CAL Taste dr cken Die Abgabe beginnen 10 342 FLOW RATE Die momentane Durchflussmenge wird alle 0 7 Sekunden aktualisiert Deshalb kann bei den niedrigeren Durchflussmengen eine relativ instabile Anzeige auftreten Je gr er die Durchflussmenge ist desto h her ist die Stabilit t des gelesenen Wertes DEUTSCH Achtung Die Durchflussmenge wird in der Ma einheit der Teilmenge gemessen Haben Teilmenge und Gesamtm
42. s sie innerhalb der angegebenen F rderleistung liegt Falsch montierte Zahnr der Position des Zahnrads mit Magnet berpr fen Defektes Relais Hohe Str mungsverluste H TECHNISCHE DATEN a zahler zahler mpu Calls umn oo oo E Max Betriebs temperatur C Str mungsverlust bei max 0 3 0 3 F rderleistung SAE 10VV 40 bei Dieselkraftstoff bei 20 C z Speisung Batterien 2x15 Volt Vorgesehene Batteriedauer 18 36 monate KONFORMITATSBESCHEINIGUNG In bereinstimmung mit der Richtlinie 89 336 EWG Elektromagnetische Vertr glichkeit und folgende Neuerungen PIUSI S p A 46029 Suzzara Mantova Italy erkl rt dass das folgende Literzahler Modell K600 worauf sich diese Erkl rung bezieht folgenden anwendbaren Normen entspricht Europ ische Bestimmungen EN 61000 6 1 EN 61000 6 3 EN 55014 1 2000 EN55014 2 97 J l OF Vua Suzzara 01 01 2006 Der Vorsitzende Otto Varini DEUTSCH EXPLODED VIEW ERSATZTEILE K600 PULSER K600 METER INSTALLATION FLANEGS AND FLUX DIRECTION MONTAGES FLANSCH UND FLUSSRICHTUNG Ba x a gt La a S un x 2 N 2 2 N GA lt gt ys os LO ID ITS a Sa Sa Ll Ss OQO Ze SS N s L7 gt gt NS LT N xLY 2 o 4
43. swirkungen Einige Sekunden nach erfolgter Fl ssigkeitsabgabe geht die Anzeige des unteren Registers von nullbarer Gesamtmenge auf absolute Gesamtmenge ber Die Schrift RESET ber dem Wort TOTAL erlischt und der Wert der nullbaren Gesamtmenge wird durch die absolute Gesamtmenge ersetzt Dieser Zustand wird Pause oder Standby genannt und bleibt bestehen solange der Benutzer keine weiteren Operationen an dem Meter vornimmt C2 2 Nullen der Teilmenge Bau amp aqua Ga HABA ca ADAADA AE Das Register der Teilmenge kann durch Dr cken der RESET Taste genullt werden wenn sich die Messuhr in Standby Status befindet d h wenn das Display die Schrift TOTAL anzeigt Nach dem Dr cken der RESET Taste zeigt das Display w hrend der Nullstellung nacheinander zun chst alle eingeschalteten Ziffern und dann alle ausgeschalteten Ziffem an Nach dem Vorgang wird zunachst die genullte Teilmenge und Reset Total angezeigt und nach wenigen Sekunden wird Reset Total durch die NICHT nullbare Gesamtmenge Total ersetzt 2 Nullen der nullbaren mtmen R Die nullbare Gesamtmenge kann nur dann genullt werden wenn zuvor die Nullung des Teilmengen Registers erfolgt ist Die Nulllung der Gesamtmenge erfolgt durch ein langeres Drucken der RESET Taste wahrend auf dem Display die Schrift RESET TOTAL angezeigt wird wie in der folgenden Anzeige Es sind schematisch die folgenden Schritte durchzuf hren 1 Abwarten bis da
44. t time in this example Litres Litres Every short press of the RESET key the various combinations of the units of measurements are scrolled as shown below By pressing the CAL key at length the new settings will be stored the METER will pass through the start cycle and will then be ready to dispense in the set units ATTENTION The Resettable Total and Total registers will be automatically changed to the new unit of measurement NO new calibration is required after changing the Unit of Measurement The METER has been designed to require a minimum amount of maintenance The only maintenance jobs required are e Battery change necessary when batteries have run down ONLY FOR METER VERSIONS Cleaning the measuring chamber This may be necessary due to the particular nature of the dispensed fluids or due to the presence of solid particles following bad filtering 1 Changing the batteries The METER is complete with 2 x 1 5 V alkaline batteries SIZE N The METER features two low battery alarm levels 1 When the battery charge falls below the first level on the LCD the fixed battery symbol appears wa aaa In this condition the METER continues to operate correctly but the fixed icon wars the user that it is time to change the batteries 2 If meter operation continues without changing the batteries the second battery alarm level will be reached which will prevent operation In this condition the battery i
45. tch located outside the measuring chamber guarantees the seal of the measuring chamber and ensures the transmission of the impulses generated by the rotation of the gears to the microprocessor The meter housing is manufactured of extruded aluminium and is fumished with extemal guides for a practical and simple installation The various models are differentiated by the length of the housing which is related to their ability to function at higher flow rates The meter body is made of die cast aluminium and fitted with connections for the installation of threaded flanges suitable for any type of tubing At the inlet opening a filtering disk of stainless steel mesh is installed which can be accessed from the outside by removing the flange close to the flow inlet side The user can choose between two different operating modes Normal Mode Mode with display of Partial and Total dispensed quantities Flow Rate Mode Mode with display of Flow Rate as well as Partial dispensed quantity The METER features a non volatile memory for storing the dispensing data even in the event of a complete power break for long periods Main components The measurement DISPLAY LCD CAL BUTTON electronics and the LCD display are fitted in the top part of the meter RESET isolated from the fluid bath BUTTON BATTERY measuring chamber and HOUSING sealed from the outside by FILTER means of a cover MEASURIN
46. te D 3 Calibrati K600 METER permits making quick and precise electronic calibration by changing the Calibration Factor K FACTOR Two procedures are available for changing the Calibration Factor 1 In Field Calibration performed by means of a dispensing operation 2 Direct Calibration performed by directly changing the calibration factor The calibration phases can be entered by keeping the CAL key pressed for a long time to Display the currently used calibration factor Retum to factory calibration Factory K Factor after a previous calibration by the user Change the calibration factor using one of the two previously indicated procedures 1 In calibration mode the partial and total dispensed quantities indicated on the display screen take on different meanings according to the calibration procedure phase 2 In calibration mode the METER cannot be used for normal dispensing operations 3 In Calibration mode the totals are not increased ATTENTION The METER features a non volatile memory that keeps the data concerning calibration and total dispensed quantity stored for an indefinite time even in the case of a long power break after changing the batteries calibration need not be repeated D 3 1 Display of Current Calibration Factor and Restoring Factory Factor gt gt gt By pressing the CAL key while the appliance is in Standby the display page appears showing the current ca