        Edwards PVEK Valves
         Contents
1.      36 PVEK Valves PVEK Ventile Vannes PVEK    Symptom Symptom Sympt  me Check Pr  fen V  rification Action Ma  nahmnen Remede    The valve leaks  Das Ventil ist undicht   La vanne fuit     Table 4   Fault finding  continued   Tabelle 4   Fehlersuche  Fortsetzung     Is the valve body    O    ring or seating groove  damaged    Sind der O Ring des Ventilk  rpers oder die Pafsrille  besch  digt    Le joint torique du corps de la vanne ou la gorge de  centrage de ce joint est endommag       Is the valve pad      O    ring or seating groove  damaged     Sind der O Ring des Ventiltellers oder die Pa  rille  besch  digt    Le joint torique du bloc de la vanne ou la gorge de  centrage de ce joint est endommage     Is there a bellows leak   Ist der Faltenbalg undicht   Le soufflet fuit     Tableau 4   Recherche des causes de pannes  suite     PVEK Valves PVEK Ventile Vannes PVEK    Dismantle the valve and check the      O    ring and seating  groove  see Section 5 2     Refinish and or replace as necessary    Das Ventil zerlegen und den O Ring und die Pafsrille  pr  fen  siehe Abschnitt 5 2     Nach Erfordernis neu bearbeiten und oder  austauschen    Demontez la vanne pour v  rifier le joint torique et sa  gorge de positionnement  voir paragraphe 5 2    Proc  dez aux retouches et ou remplacements  n  cessaires     Dismantle the valve and check the      O    ring and seating  groove  see Section 5 2     Refinish and or replace as necessary    Das Ventil zerlegen und den O Ring und di
2.     Gewicht  kg  IPVEKA  t 0 8 t 1 8 t 4 6 t  Poids  kg  PVEKS 0 9 1 2 2 4 6 4  IPVEKS  t 1271 231 6 8 t                        Right angled valve Eckventil Vanne a angle droit    In line valve  note that there is no PV10EK in line valve   Durchgangsventil  Es gibt kein PV10EK   Durchgangsventil     Vanne a passage direct  Note  il n   existe pas de vanne PV10EK    passage direct     Table 3   Mechanical data  Tabelle 3   Mechanische Daten    Tableau 3   Caract  ristiques m  caniques    PVEK Valves PVEK Ventile Vannes PVEK    A The electrical supply connector and the microswitch connector  must be connected using the gasket supplied  and the correct cable  diameters must be used  in order to meet the requirements of IP55     A Um den Anforderungen von IP 55 zu entsprechen miissen  Netzstecker und Mikroschalterstecker unter Verwendung der  mitgelieferten Manschette verbunden werden und die richtigen  Kabeldurchmesser m  ssen verwendet werden     A Les connecteurs de l   alimentation   lectrique et du microrupteur  doivent   tre raccord  s a l   aide du joint fourni  et les diam  tres de  cable corrects   tre utilis  s pour satisfaire aux exigences d   IP55     11                      Figure 2   Right angled valve dimensions  Abbildung 2   Abmessungen der Eckventile  Figure 2   Dimensions de la vanne    angle droit    12    2  UNTEN                               AG 0715 C             PVEK Valves PVEK Ventile Vannes PVEK                         ip  Ill          AG 0350 B    Figu
3.    EMC Requirements       A1 1998   A2 2001   Industrial environment   Class B Emissions     following the provisions of    73   023   EEC Low Voltage Directive     89   336   EEC Electromagnetic Compatibility Directive            JO IL Tuy deet  CaAL eY    Dr  J D  Watson  Technical Director  VEMD Date and Place       This product has been manufactured under a quality system registered to ISO9001          M    BOC EDWARDS    C413 02 000  C413 04 000  C414 02 000  C414 04 000    C416 32 000  C416 33 000  C416 53 000  C416 54 000       P900 75 200 Issue E 2B01 010    Declaration of Incorporation    BOC Edwards    Manor Royal    Crawley    West Sussex RH10 2LW  UK    declare under our sole responsibility that the machine s     Right Angled Valves     PV10EKA  220 V   PV10EKA  110 V   PV16EKA  220 V   PV16EKA  110 V   PV25EKA  220 V     In Line Valves     PV16EKA  220 V  PV16EKA  110 V    C411 01 000  C411 03 000  C412 01 000  C412 03 000  C413 01 000    C416 10 000  C416 11 000    PV25EKA  110 V   PV40EKA  220 V   PV40EKA  110 V   PV16EKS  220 V   PV16EKS  110 V     PV40EKA  220 V   PV40EKA  110 V   PV16EKS  220 V     C413 03 000  C414 01 000  C414 03 000  C412 02 000  C412 04 000    C416 51 000  C416 52 000  C416 12 000    PV25EKS  220 V   PV25EKS  110 V   PV40EKS  220 V   PV40EKS  110 V     PV25EKS  220 V   PV25EKS  110 V            PV40EKS  220 V   PV40EKS  110 V        PV25EKA  220 V  C416 30 000       PV25EKA  110 V C416 31 000 PV16EKS  110 V  C416 13 000    to which this 
4.    Sectional view of PVEK valve   key     gt     ea ee    o    10   11   12     D  tails d une vanne    passage direct    Coffret   lectrique   Chapeau sup  rieur   Garniture Sorbathane   Palier   Tige fixe   Bobine   Ensemble soufflet p  le mobile  Logement de l   actionneur   Vis de fixation   Joint torique du corps de la vanne  Corps de la vanne   Joint torique du bloc de la vanne    Abbildung 7   Schnittbild des PVEK Ventils  Legende  Figure 7   Vue en coupe d   une vanne PVEK   l  gende    PVEK Valves PVEK Ventile Vannes PVEK    AW 6823 A                                                             Figure 7   Sectional view of PVEK valve  Abbildung 7   Schnittbild eines PVEK Ventils  Figure 7   Vue en coupe d une vanne PVEK    PVEK Valves PVEK Ventile Vannes PVEK                   31    5 3 Replace the bellows pole piece  assembly    Refer to Figure 7 for item numbers shown in  brackets     1  Dismantle the valve as described in  Section 5 2     2  Remove the old bellows  pole piece  assembly  7  and discard     3  Fit the new valve pad    O    ring  12  to the  new bellows assembly  apply a light wipe of  high vacuum grease to ease the fit     4  Fit the bellows assembly into the  actuator case  ensure free movement of the    pole piece in the actuator case     5  Reassemble the valve as described in  Section 5 2     32    54 Replace the valve body and  pad    O    rings    Refer to Figure 7 for item numbers shown in  brackets     1  Dismantle the valve as described in  
5.  Kirchheim   Munich   Tel   49  899919180  Fax H49  89 99 19 18 99    HONG KONG S A R     BOC EDWARDS  ASA    12 Chun Yat Street   Tseung Kwan O Industrial Estate  Tseung Kwan O  Kowloon  Hong Kong S A R    Tel 4852  2372 2640   Fax  852  2796 9095    INDIA    BOC EDWARDS   DIVIN  OF BOC INDIA LIMITED  203 Surya Kiran Building   19 Kasturba Gandhi Marg   New Delhi   110 001   India   Tel 91  11 851 0065   Fax  91  11 851 0245    ISRAEL    EDWARDS ISRAEL VACUUM LTD     5 Habarzel Blvd   Gat 2000 Industrial Zone  Qiryat Gat 82000   Tel   972  8 681 0633  Fax  972  8 681 0640    ITALY    BOC EDWARDS   Via Carpaccio 35   20090 Trezzano sul Navidio  Milan   Tel   39  02 48 4471   Fax  H39  02 48 401638    JAPAN    HEADQUARTERS   BOC EDWARDS   Shuwa Shiba Park Building A 3F  2 4 1 Shibakoen Minato ku  Tokyo  105 0011   Tel 81   0  3 5470 6530   Fax  H81   0  3 5470 6521    PLEASE CONTACT ANY OF THESE COMPANIES FOR DETAILS OF OTHER SALES AND SERVICE CENTRESIN YOUR AREA   BOC Edwards is part of BOC Limited  BOC Edwards and the stripe symbol are trade marks of The BOC Group       BOC Edwards 2003    http   www bocedwards com  info bocedwards com    KOREA    HEADQUARTERS   SONGWON EDWARDSLTD   5th FL  Daewoo Engineering Bldg   Soonae dong   Bundang gu  Sungnam City  Kyundki do  Korea   Tel  82  31 716 7070   Fax 82  31 738 1001 3    FACTORY  amp GV   SONGWON EDWARDSLTD   625 7 Upsong dong   Chunan City   Chungchong N am do   Korea   Tel  82  41 621 7070   Fax 82  41 621 7700    SINGAPO
6.  O    rings Fluoroelastomer    Hin   alle    als a    2 1  Sieh    22  Lag    Sieh    2 3  Sieh    2 4    Die  herg    Ven  PVE    PVE  Falt    O R    2 5 Legislation and standards 2 5    The valves have been designed in compliance Die  with the following legislation and standards  Vo    73 023 EEC   Low Voltage Directive     89 336  EEC   Electromagnetic Compatibility  Directive     EN61010   Safety Requirements for Electrical  Equipment for Measurement  Control and  Laboratory Use   Part 1  General  Requirements     EN61326   Industrial Location  Class B  Emissions    Electrical Equipment for  Measurement  Control and Laboratory Use    EMC requirements     EN60529   Degrees of Protection Provided by  Enclosures  IP Code      Pneurop 6606   Vacuum Flanges and  Connections     PVEK Valves PVEK Ventile Vannes PVEK                                  PV10EK PV16EK PV25EK PV40EK  Ambient temperature  operation   Umgebungstemperatur  Betrieb  5 45   C 5 45   C 5  50  C 5   50   C  Temp  rature ambiante  fonctionnement   Ambient temperature  storage   Umgebungstemperatur  Lagerung   30   70   C  30   70   C  30   70   C  30   70   C  Temp  rature ambiante  stockage   Ambient humidity  operation  80  decreasing linearly to 50  relative humidity at 40   C  Umgebungsluftfeuchte  Betrieb  80  linear abfallend zu 50  relativer Luftfeuchte bei 40  C  Humidit   ambiante  fonctionnement  80    diminution lin  aire jusqu    50   d humidit   relative    40   C  Operating altitude operating con
7.  body and actuator case size  the size  of the electrical box  Figure 1  item 7  is identical  in all valve models     EEE e Sr Je E E E ee    NOO Qi e O   N  gt     Position indicator socket  Electrical supply socket  Valve body   Valve port   Valve port   Mounting holes  Electrical box    Anschlu   Stellungsindikator  Anschlu   Stromversorgung  Ventilk  rper   Ventil  ffnung   Ventil  ffnung  Montagel  cher   Elektrischer Schaltkasten    Prise femelle de l indicateur de position  Prise femelle de l alimentation   lectrique  Corps de la vanne   Orifice de la vanne   Orifice de la vanne   Trous de fixation   Coffret   lectrique    PVEK Valves PVEK Ventile Vannes PVEK             AG 0141 A    Figure 1   PVEK valve  PV10EK right angled valve shown   Abbildung 1   PVEK Ventil  dargestellt wird das Eckventil PV10EK   Figure 1   Vanne PVEK  Illustration du mod  le PV10EK    angle droit     1 3 Construction    Refer to the sectional view of the PVEK valve in  Figure 7 to identify the item numbers in  brackets     The valve mechanism is a solenoid operated  moving pole with an integral valve pad and  bellows assembly  7   The vacuum system is  isolated from atmosphere by a fluoroelastomer     O    ring static seal  10  and a stainless steel  bellows for dynamic sealing  The valve pad also  seals against the valve body with a  fluoroelastomer    O    ring  12   The valve body  terminates in two ports with NW flanges     A PCB inside the electrical box  1  controls the  valve actuatio
8.  finding  Tabelle 4   Fehlersuche    Has the electrical supply failed   Ist die Stromversorgung ausgefallen   Il y aeu une panne de courant     Is there a loose connection in the electrical supply  socket    Gibt es eine lose Verbindung in der  Netzanschlufsbuchse    Il y a un faux contact dans la prise femelle  d   alimentation   lectrique     Is the valve obstructed   Ist das Ventil durch einen Fremdk  rper blockiert   La vanne est bloqu  e     Tableau 4   Recherche des causes de pannes    PVEK Valves PVEK Ventile Vannes PVEK    Check the electrical supply and repair as necessary   Stromversorgung pr  fen und ggfs  reparieren   V  rifiez l alimentation   lectrique et proc  dez aux  r  parations n  cessaires     Remove the electrical supply socket  check the electrical    supply cable to socket connections and repair as  necessary  see Section 3 3 1      Die Netzanschlu  buchse ausbauen  die Anschl  sse des  Netzkabels an die Buchse pr  fen und wie erforderlich    reparieren  siehe Abschnitt 3 3 1      Deposez cette prise femelle  verifiez les raccordements  entre le c  ble et cette prise et proc  dez aux r  parations    n  cessaires  voir paragraphe 3 3 1      Dismantle the valve  see Section 5 2  and remove the    obstruction   Das Ventil zerlegen  siehe Abschnitt 5 2  und das  Hindernis entfernen     D  montez cette vanne  voir paragraphe 5 2  et   liminez    la cause de ce blocage        35    Symptom Symptom Sympt  me Check Pr  fen V  rification Action Ma  nahmnen Remed
9.  you can rotate the valve body from  its standard position  in 90 steps for the  right angled valve and in 180 steps for the  in line valve   Remove the four screws which  secure the solenoid actuating cylinder to the  valve body and reassemble with the cylinder  turned in the required direction     3 3 Electrical connections    WARNING  Ensure that the electrical installation of the  PVEK valve conforms with your local and  national safety requirements  It must be  connected to a suitable fused and protected  electrical supply and a suitable earth  ground   point     WARNING  In order to comply with EN61010  the valve  must be connected to a suitable 2 pole circuit  breaker which is labelled appropriately and  mounted in close proximity  within easy reach  of the operator        3 3 1 Fit your own electrical supply cable    Use the following procedure to fit your own  electrical supply cable to the PVEK valve  Refer  to Figure 4 for item numbers in brackets     1  Check that the electrical supply corresponds  with the voltage stated on the valve label     18    2  Undo the screw  5  and remove the electrical  supply socket  4  from the electrical box  1    Remove the sealing gland  2  and prise out  the connector block  3      3  Loosen the strain relief nut  6  and pass the  electrical supply cable through the nut and  into the socket  Refer to Table 2 for  information on the correct cable diameter     4  Connect the electrical supply cable to the  connector block as shown 
10. 05 C411 01 007 C411 01 007 C416 02 801 C416 02 811  PV25EKS  220 V  C413 01 800 C413 01 800 C413 01 806 C413 01 806 C413 01 007 C413 01 007 C416 22 801 C416 22 811  PV25EKS  110 V  C413 01 800 C413 01 800 C413 01 805 C413 01 805 C413 01 007 C413 01 007 C416 22 801 C416 22 811  PV40EKS  220 V    C414 01 800 C414 01 800 C414 01 806 C414 01 806 C414 01 007 C414 01 007 C416 42 801 C416 42 811  PV40EKS  110 V    C414 01 800 C414 01 800 C414 01 805 C414 01 805 C414 01 007 C414 01 007 C416 42 801 C416 42 811                                  Table 5   Spares    Tabelle 5   Ersatzteile  Tableau 5   Pi  ces d  tach  es    PVEK Valves PVEK Ventile Vannes PVEK    41       74 Accessories 74 Zubeh  r 74 Accessoires    Electrical supply Netzkabelzubeh  r C411 01 090 C  ble d alimentation  cable accessory C411 01 090   lectrique C411 01 090    42 PVEK Valves PVEK Ventile Vannes PVEK    P900 70 000 Issue K    M4 BOC EDWARDS Form HS1       Return of BOC Edwards Equipment     Procedure  INTRODUCTION    Before returning your equipment  you must warn BOC Edwards if substances you used  and produced  in the equipment can be hazardous  This information is fundamental to  the safety of our Service Centre employees and will determine the procedures employed to service your equipment     Complete the Declaration  HS2  and send it to BOC Edwards before you dispatch the equipment  It is important to note that this declaration is for BOC Edwards  internal use only  and has no relationship to local  natio
11. 4   Elektrische Anschl  sse  Figure 4   Connecteurs   lectriques     20 PVEK Valves PVEK Ventile Vannes PVEK    1  Live  2  Neutral  3  Earth  ground     1  Phase  2  Neutral  3  Erdung  1  Phase  Neutre    3  Terre  masse     Figure 5   Electrical supply connections  Abbildung 5   Netzanschl  sse  Figure 5   Connexions   lectriques    PVEK Valves PVEK Ventile Vannes PVEK    d    Ber     lt      ke  a     AG 0717 B       21    3 3 2 Fit the electrical supply cable  accessory    Use the following procedure to fit the electrical  supply cable accessory  Refer to Figure 4 for item  numbers in brackets     The accessory is supplied as a fully assembled  cable  together with a new sealing gland and  socket retaining screw     1  Undo the screw  5  and remove the existing  electrical supply socket  4  from the  electrical box  1  on the valve     2  Fitthe new sealing gland  2  to the socket  4   on the electrical supply cable accessory     3  Push the socket  4  onto the three connector  pins on the electrical box     4  Fit the new socket retaining screw  5  and  tighten  ensure that there is a slight  compression of the sealing gland     5  Fitthe plug on the other end of the electrical    supply cable accessory to a suitable electrical  supply outlet     22    3 3 3 Position indicator connections    WARNING  Do not use the position indicator as a safety    interlock device  Under certain circumstances  the position indicator may not operate  correctly        The reed switch pos
12. 44  1942 652652  Fax  44  1942 652651    AMERICA  USA     USA HEADQUARTERS   BOC EDWARDS   One Edwards Park   301 Bdlardvale Street   Wilmington  MA 01887   Tel 1  978 658 5410   Toll free  USA only  1 800 848 9800  Fax 1  978 658 7969    3901 Burton Drive   Santa Clara  CA 95054  Tel 1  408 496 1177  Fax 1  408 496 1188    1810 West Drake Drive  Suite 101   Tempe  AZ 85283   Tel 1  602 777 7007  Fax 1  602 777 2244    11701 Stonehollow Drive  Suite 100   Austin  TX 78758   Tel  1  512 491 6622  Fax 1  512 491 0629    3501 Island Avenue   Philadelphia  PA 19153  Tel 1  215 365 8653  Fax 1  978 753 6846    BELGIUM    BOC EDWARDS  Bergensesteenweg 709  B1600 Sint Pieters Leeuw  Brussels   Tel  32  2 363 0030   Fax   32  2 363 0064    BRAZIL    BOC DO BRASL LTDA   DIVIS  O EDWARDS ALTO VACO  Rua Bernado W rona 222   02710 S  o Paulo SP   Tel  55  11 3952 5000   Fax  H55  11 3965 2766    CANADA    BOC EDWARDS   5975 Falbourne Street  Mississauga  Ontario LSR3W 6  Canada   Tel  1  905 501 2558   Fax  H1  905 501 1632    12055 Cote de Liesse  Dorval  Quebec H9P1B4  Canada   Tel  1  514 631 3501  Fax  H1  514 631 3502    CHINA    BOC TRADING    SHANGHAI  CO  LTD    23 Fu Te Road  N    Wai Gao Qiao Free Trade Zone  Pudong   Shanghai  200131   PRC China   Tel  H86 21  5866 9618   Fax 86 21  5866 9993    FRANCE    BOC EDWARDS   125 Avenue Louis Roche  92238 Gennevilliers  Cedex  Paris   Tel  33  1 47 98 24 O1  Fax  33  1 47 98 44 54    GERMANY    BOC EDWARDS  Ammerthalstra  e 36  85551
13. C411 02 885  Issue G    Instruction Manual    Betriebsanleitung ee  Mode d   emploi PVEK Ventile  Vannes PVEK       M    BOC EDWARDS    Manor Royal  Crawley  West Sussex  RH10 9LW  UK  Telephone   44  0  1293 528844 Fax   44  0  1293 533453    http   www bocedwards com    Declaration of Conformity    BOC Edwards    Manor Royal    Crawley    West Sussex RH10 2LW  UK       declare under our sole responsibility that the product s     Right Angled Valves   PV10EKA  220 V  C411 01 000 PV25EKA  110 V  C413 03 000  PV10EKA  110 V  C411 03 000 PV40EKA  220 V  C414 01 000  PV16EKA  220 V  C412 01 000 PV40EKA  110 V  C414 03 000  PV16EKA  110 V  C412 03 000 PV16EKS  220 V  C412 02 000  PV25EKA  220 V  C413 01 000 PV16EKS  110 V  C412 04 000  In Line Valves   PV16EKA  220 V  C416 10 000 PV40EKA  220 V  C416 51 000  PV16EKA  110 V  C416 11 000 PV40EKA  110 V  C416 52 000  PV25EKA  220 V  C416 30 000 PV16EKS  220 V  C416 12 000  PV25EKA  110 V  C416 31 000 PV16EKS  110 V  C416 13 000    PVE Valve Mains Lead C411 01 090    to which this declaration relates is in conformity with the following standard s  or other normative document s     PV25EKS  220 V   PV25EKS  110 V   PV40EKS  220 V   PV40EKS  110 V     PV25EKS  220 V   PV25EKS  110 V   PV40EKS  220 V   PV40EKS  110 V     EN61010 1 2001 Safety Requirements for Electrical Equipment for Measurement  Control and Laboratory Use      Part 1  General Requirements     EN61326 1997 Electrical Equipment for Measurement  Control and Laboratory Use
14. K Ventile Vannes PVEK    Section    5 1  SAM  5 1 2  52  5 3    5 4  5 5    5 6    6 1  6 2    7 1  7 2  7 3  74    ii    MAINTENANCE   General   Safety information  Fluoroelastomers   Dismantle and inspect the valve  Replace the bellows pole piece  assembly   Replace the valve body and  pad    O    rings   Electrical service kit   Fault finding    STORAGE AND DISPOSAL  Storage  Disposal    SERVICE  SPARES AND  ACCESSORIES  Introduction   Service   Spares   Accessories    RETURN OF BOC EDWARDS  EQUIPMENT    Page    27  27  27  28  29    32    33  34  35    38  38  38    39  39  40  41  42    Kapitel    5   5 1  5 1 1  5 1 2  5 2  3 9    5 4  5 9    5 6      lt  a Ns aH Bras ei Ft UD Fra ei    a       6 1  6 2    rm Mm    7 1  7 2  7 3  7 4    N m ai m m ER    Fel    Illustrations    Figure    1 PVEK valve  PV10EK right angled  valve shown    Right angled valve dimensions  In line valve dimensions   Electrical connectors   Electrical supply connections  Position indicator connections  Sectional view of PVEK valve    ND 6  amp     ND    Tables  Table    1 Performance  operating and  storage conditions  Electrical data   Mechanical data   Fault finding   Spares    O1  amp     N    Page    12  13  20  21  24  31    Page    10  11  35  41    PVEK Valves PVEK Ventile Vannes PVEK    1 INTRODUCTION    1 1 Scope and definitions    This manual provides installation  operation and  maintenance instructions for the BOC Edwards  range of PVEK valves  You must use the valves  as specified 
15. RE    BOC EDWARDS  ASA   42 Loyang Drive   Loyang Industrial Estate  Singapore 508962   Tel 65  6546 8408  Fax 65  6546 8407    TAIWAN  R O C     EDWARDS TECHNOLOGIES  LIMITED   No  434 Chung hua Road  Toufen Town  Miaoli County  Taiwan ROC   Tel  886  37 611422   Fax  H886  37 611401    Produced by Technical Publicity Techpublicity  edwards boc com    ZS BOC EDWARDS    
16. Remove all the packing materials and protective  covers and check the PVEK valve     If the valve is damaged  notify your supplier and  the carrier in writing within three days  state the  Item Number of the valve together with your  order number and your supplier   s invoice  number  Retain the packing materials for  inspection  Do not use the valve     If the valve is not to be used immediately     replace the protective covers  Store the valve in  suitable conditions  as described in Section 6     16    3 2 Install the valve    WARNING  Take appropriate safety precautions when  you install the valve in a system in which  dangerous process substances have been  pumped     WARNING  Fit a cover to any valve port which is open to  atmosphere  Access to open ports is    dangerous     CAUTION  We recommend that you provide additional  support for a PV40EKA in line valve  The  valve flanges of an unsupported PV40EKA  in line valve may be distorted by the mass of  the valve  Alternatively  fit a PV40EKS in line  valve        The valve is normally supported by the pipeline  it is fitted to and can be mounted in any  orientation  Two threaded holes in the  valve body allow for additional support  if  required  the dimensions of these holes are  defined in Section 2  Do not exceed the specified  maximum depth of thread or you will damage  the valve  Connect the valve to your vacuum  system with standard NW coupling  components     PVEK Valves PVEK Ventile Vannes PVEK    If necessary 
17. Section 5 2     2  Remove the valve body    O    ring  10  from  the valve body and discard     3  Inspect the    O    ring groove and contact  surfaces  Refinish any surfaces which are  damaged     4  Fit the new valve body    O    ring  10  to the  valve body     5  Remove the bellows pole piece assembly  7      6  Remove and discard the valve pad    O    ring   12  from the bellows pole piece assembly     7  Inspect the      O    ring groove and contact  surfaces  Refinish any surfaces which are  damaged     8  Fit the new valve pad    O    ring to the  bellows pole piece assembly  apply a light  wipe of high vacuum grease to ease the fit     9  Refit the bellows pole piece assembly and    reassemble the valve as described in  Section 5 2     PVEK Valves PVEK Ventile Vannes PVEK    5 5 Electrical service kit    WARNING  Do not attempt to open the electrical box   Hazardous voltages present inside the  electrical box may cause death or serious  injury     WARNING  The printed circuit assembly should only be  replaced by a service engineer or a suitably  trained and supervised technician        An electrical service kit containing a replacement  printed circuit assembly is available as a spare   refer to Section 7 3     34    5 6 Fault finding Fehlersuche Recherche des causes de pannes    Symptom Symptom Sympt  me Check Pr  fen Verification Action MaSnahmnen Rem  de    The valve fails to operate   Das Ventil arbeitet nicht   La vanne refuse de fonctionner     Table 4   Fault
18. Type de vanne valve  valve Gerade valve  valve Gerade valve  valve Gerade valve  valve Gerade  Rechtwinkliges  durchgehendes   Rechtwinkliges  durchgehendes  Rechtwinkliges   durchgehendes  Rechtwinkliges durchgehendes  Ventil  Ventil Vanne    Ventil  Ventil Vanne    Ventil  Ventil Vanne    Ventil  Ventil Vanne     Vanne    angle coulement   Vanne    angle coulement   Vanne    angle coulement   Vanne    angle coulement  droit rectiligne droit rectiligne droit rectiligne droit rectiligne   PV10EKA  220 NN C411 01 800   C411 01 806   C411 01 007   C411 01 816    PV10EKA  110 V   C411 01 800   C411 01 805   C411 01 007   C411 01 816    PV16EKA  220 V   C411 01 800 C411 01 800 C411 01 806 C411 01 806 C411 01 007 C411 01 007 C412 01 816 C416 01 802  PV16EKA  110 V   C411 01 800 C411 01 800 C411 01 805 C411 01 805 C411 01 007 C411 01 007 C412 01 816 C416 01 802  PV25EKA  220 V   C413 01 800 C413 01 800 C413 01 806 C413 01 806 C413 01 007 C413 01 007 C413 01 816 C416 21 802  PV25EKA  110 V   C413 01 800 C413 01 800 C413 01 805 C413 01 805 C413 01 007 C413 01 007 C413 01 816 C416 21 802  PV40EKA  220 NN C414 01 800 C414 01 800 C414 01 806 C414 01 806 C414 01 007 C414 01 007 C414 01 816 C416 41 802  PV40EKA  110 V   C414 01 800 C414 01 800 C414 01 805 C414 01 806 C414 01 007 C414 01 007 C414 01 816 C416 41 802  PV16EKS  220 V  C411 01 800 C411 01 800 C411 01 806 C411 01 806 C411 01 007 C411 01 007 C416 02 801 C416 02 811  PV16EKS  110 V    C411 01 800 C411 01 800 C411 01 805 C411 01 8
19. aration in a suitable envelope  attach the envelope securely to the outside of the equipment package  in a clear weatherproof bag     WRITE YOUR RETURN AUTHORISATION NUMBER CLEARLY ON THE OUTSIDE OF THE ENVELOPE  OR ON THE OUTSIDE OF THE EQUIPMENT PACKAGE              M4 BOC EDWARDS Form HS2       Return of BOC Edwards Equipment   Declaration en    You must     Know about all of the substances which have been used and produced in the equipment before you complete this Declaration  Read the Return of BOC Edwards Equipment   Procedure  HS1  before you complete this Declaration   e Contact BOC Edwards to obtain a Return Authorisation Number and to obtain advice if you have any questions   e Send this form to BOC Edwards before you return your equipment    SECTION 1  EQUIPMENT    Equipment System Name IF APPLICABLE   Part Number       Tool Reference Number          Serial Number Process          Has the equipment been used  tested or operated   Failure Date       YES L  Go to Section 2 NO  _  Go to Section 4 Serial Number of  Replacement Equipment       SECTION 2  SUBSTANCES IN CONTACT WITH THE EQUIPMENT    Are any substances used or produced in the equipment  Note 1   BOC Edwards will not accept delivery of any equipment that is    contaminated with radioactive substances  biological infectious agents   Radioactive  biological or infectious agents  mercury  PCB   s  dioxins or sodium azide  unless you   mercury  poly chlorinated biphenyls  PCBs   e Decontaminate the equipment  d
20. cian   Obey your local and national safety  requirements    Observe all appropriate safety precautions  when you maintain a valve from a system in  which dangerous process substances have  been pumped    Isolate the valve from the electrical supply  and your vacuum system before you start  maintenance    Observe all appropriate safety precautions  when you come into contact with solvents  and fluoroeleastomer  OH rings    Ensure that you do maintenance in a well  ventilated area    PVEK Valves PVEK Ventile Vannes PVEK     x    Do not use abrasive or reactive chemicals to  clean the valve    Do not use solvents to clean  OH rings    Safely dispose of all components which have  been contaminated by dangerous process  substances     5 1 2 Fluoroelastomers    The seals and      O    rings used in the PVEK valve  are made from a fluoroelastomer   Fluoroelastomers can decompose into very  dangerous substances if they are heated to   260 Cand above  The valve may have  overheated if your system has been misused  if it  has malfunctioned or if the valve has been in a  fire  If the valve has overheated  ensure that you  observe the appropriate safety precautions to  prevent contact with the seals and      O    rings     28    5 2 Dismantle and inspect the valve    CAUTION  When you reassemble the valve  make sure    that    O    rings are seated properly in their  locating grooves and are not trapped or  pinched        Note  The best type of grease to use is dependent on  the gases pu
21. d wide network of  distributors     The majority of these centres employ Service  Engineers who have undergone comprehensive  BOC Edwards training courses     Order spare parts and accessories from your  nearest BOC Edwards company or distributor   When you order  please state for each part  required     Model and Item Number of your equipment  Serial number  if any     Item Number and description of the part    PVEK Valves PVEK Ventile Vannes PVEK    7 2 Service    BOC Edwards products are supported by a  world wide network of BOC Edwards Service  Centres  Each Service Centre offers a wide range  of options including  equipment  decontamination  service exchange  repair   rebuild and testing to factory specifications   Equipment which has been serviced  repaired or  rebuilt is returned with a full warranty     Your local Service Centre can also provide BOC  Edwards engineers to support on site  maintenance  service or repair of your  equipment     For more information about service options     contact your nearest Service Centre or other BOC  Edwards company     40                7 3 Spares 7 3 Ersatzteile 7 3 Pi  ces d  tach  es  ge Seege Electrical service kit Bellows Valve Body  O Ring Wartungssatz 8 a     SC Elektrischer Wartungssatz Faltenbalg Ventilk  rper  Jeu de maintenance de joints e p        Jeu de maintenance   lectrique Soufflets Corps du clapet  toriques  Valve type  Ventiltyp Right angled In line Right angled In line Right angled In line Right angled In line  
22. declaration relates is intended to be incorporated into other equipment and not to function independently     The machine s  is in conformity with the following standard s  or other normative document s   98 37 EC Machinery Directive     The machine s  must not be put into service until the equipment into which it is incorporated has been brought  into conformity with the provisions of the Machinery Directive  98 37 EC     Dr  J  D  Watson  Technical Manager Date and Place    Vacuum Equipment and Exhaust Management Product Divisions    M    BOC EDWARDS    C413 02 000  C413 04 000  C414 02 000  C414 04 000    C416 32 000  C416 33 000  C416 53 000  C416 54 000       P900 76 200 IssueF 2B01 010    Falcon06059 06 04    CONTENTS    Section   1 INTRODUCTION   1 1 Scope and definitions  1 2 Description   1 3 Construction   1 4 Operation   2 TECHNICAL DATA  2 1 Mechanical data    2 2    2 3  2 4  25  2 6  2 6 1  2 6 2    3 1  32  3 3  DO    3 3 2    3 9 3    4 1  4 2    Performance  operating and  storage conditions  Electrical data   Materials   Legislation and standards  Product Item Numbers  Right angled valves   In line valves    INSTALLATION   Unpack and inspect   Install the valve   Electrical connections   Fit your own electrical supply  cable   Fit the electrical supply cable  accessory   Position indicator connections    OPERATION  General  Position indicator    Page    UE DE HR    N ON    NACAD    14  14  15    16  16  17  18    18    22  23    25  25  25    PVEK Valves PVE
23. ditions Up to 2000 m  For indoor use only  Betriebsh  he   ber NN Betriebsbedingungen Bis zu 2000 m  Nur f  r den Innenbetrieb  Altitude conditions de fonctionnement Jusqu    2000 m utilisation    l   int  rieur uniquement  Molecular conductance  right angled valve    Molekular Leitwert  Eckventil   31s  Als  10 1s  34151  Conductance en r  gime mol  culaire  vanne    angle  droit   Molecular conductance  in line valve    Molekular Leitwert  Durchgangsventil   z Se  615  151s   Conductance en r  gime mol  culaire  vanne     passage direct                 Pressure range  valve open    Druckbereich  Ventil offen    Gamme de pression  vanne ouverte     1x10   2 1 x 10   mbar  absolute absolut absolu     1x10     2 1x 10   Pa          Maximum pressure differential  between flanges   Maximales Druckdifferenzial  zwischen Flanschen   Pression diff  rentielle maximale  entre brides        1 x 10   mbar    1 x 10   Pa       Table 1   Performance  operating and storage conditions  Tabelle 1   Leistungs   Betriebs  und Lagerbedingungen    Tableau 1   Performances  conditions de fonctionnement et de stockage    PVEK Valves PVEK Ventile Vannes PVEK                               PV10EK PV16EK PV25EK PV40EK  Leak rate Undichtigkeitsrate Taux de fuite 1x 10    mbar1s1 1x107 Pals   Maximum cycle frequency  per hour    Maximale Zyklusfrequenz  Pro Stunde   400 400 400 400  Frequence maximale de manoeuvre  par heure   Nominal lift  mm   Nominalhub  mm  2 5 2 5 3 8 6 0  Lev  e nominale  mm   Ti
24. e    Incorrect position indication   Falsche Stellungsanzeige   Une position incorrecte est  indiquee     Is there a loose connection in the position  indication socket    Gibt es eine lose Verbindung in der  Stellungsindikator Buchse    Faux contact dans la prise femelle de l   indicateur  de position     Is the electrical supply voltage low   Ist die Versorgungsspannung niedrig   La tension d   alimentation est faible     Is the valve obstructed    Ist das Ventil durch einen Fremdk  rper blockiert   Il ya un faux contact dans la prise femelle  d   alimentation   lectrique     Remove the socket  check the cable to socket  connections and repair as necessary  see Section 3 3 1    Die Buchse ausbauen  die Anschl  sse des Kabels an die  Buchse pr  fen und wie erforderlich reparieren  siehe  Abschnitt 3 3 1     Deposez cette prise  verifiez les branchements entre le  c  ble et cette prise et proc  dez aux r  parations  n  cessaires  voir paragraphe 3 3 1      Change the electrical supply  see Section 4 2     Die Stromversorgung   ndern  siehe Abschnitt 4 2    Changez la source d alimentation   lectrique  voir  paragraphe 4 2      Dismantle the valve  see Section 5 3  and remove the  obstruction    Das Ventil zerlegen  siehe Abschnitt 5 3  und das  Hindernis entfernen    Demontez cette vanne  voir paragraphe 5 3  et   liminez  la cause de ce blocage        Table 4   Fault finding  continued   Tabelle 4   Fehlersuche  Fortsetzung   Tableau 4   Recherche des causes de pannes  suite
25. e Pafsrille  pr  fen  siehe Abschnitt 5 2     Nach Erfordernis neu bearbeiten und oder  austauschen    Demontez la vanne pour v  rifier le joint torique et sa  gorge de positionnement  voir paragraphe 5 2    Proc  dez aux retouches et ou remplacements  n  cessaires     Replace the bellows pole piece assembly  see  Section 5 3     Die Faltenbalg  Polst  ckgruppe  siehe Abschnitt 5 3   austauschen    Remplacez l   ensemble soufflet  p  le mobile  comme  indiqu   au paragraphe 5 5        37    6 STORAGE AND DISPOSAL    6 1 Storage    Isolate the valve from the electrical supply and  disconnect it from your vacuum system  Place  protective covers over the valve ports and store  the PVEK valve in cool  dry conditions until it is  required for use     When required  prepare and install the valve as  described in Section 3     6 2 Disposal    Dispose of the valve and any components  removed from it safely in accordance with all  local and national safety and environmental  requirements     Particular care must be taken with the following     Fluoroelastomers which may have been  subjected to temperatures above 260 C  see  Section 5 1 2     Components which have been contaminated  with dangerous process substances     38    7 SERVICE  SPARES AND  ACCESSORIES    71 Introduction    BOC Edwards products  spares and accessories  are available from BOC Edwards companies in  Belgium  Brazil  China  France  Germany  Israel   Italy  Japan  Korea  Singapore  United Kingdom   U S A  and a worl
26. imalstrom  Spitzenwert    Leistung  eff   0 25 A 3 VA  Intensit   maximale  pointe   puissance maximale  eff        Electrical supply plug Netzstecker   Fiche de l alimentation   lectrique  Cable diameter  Kabeldurchmesser   Diam  tre du c  ble 6   8 mm       Microswitch plug Mikroschalterstecker   Fiche du microrupteur  Maximum cable diameter 6 5 mm  Maximaler Kabeldurchmesser  Diam  tre maximal du c  ble             Table 2   Electrical data  Tabelle 2   Elektrische Daten  Tableau 2   Caract  ristiques   lectriques    10 PVEK Valves PVEK Ventile Vannes PVEK                         Dimensions  mm  see Figures 2 and 3 for keys  PV10EK PV16EK PV25EK PV40EK  Abmessungen  in mm  bzgl  Erl  uterungen siehe die Abbildungen 2 und 3   Dimensions   mm  voir l  gende des Figures 2 et 3   A 30 40 50 65  B 42 42 55 80  C 20 20 20 40  F 59  af 69  374   82  725   110  10157  H 150   f 160  142 9   182  1727 230  2227  L 116   f 126  85   142  93   170  AT  M   40 t 50    65 t  Mounting hole thread size and maximum depth  Gewindegr    e und maximale Tiefe der Montagel  cher M4x7 M4x7 M4x7 M6 x9  Filetage et profondeur maximale des orifices de montage  Valve port flange size  Flanschgr    e der Ventil  ffnung NW10 NW16 NW25 NW40  Taille de bride d   orifice de vanne  IP ratings  as defined by EN60529   valve enclosure     IP Daten  gem     EN60529   Ventilgeh  use 4 IP55 IP55 IP55 IP55  Indices IP  tels que d  finis par EN60529    enveloppe de vanne     Mass  kg  PVEKA 0 8   0 8   1 8  4 5
27. in Figure 5  Ensure  that the earth  ground  conductor is longer  than the other conductors  so that if the cable  is accidentally dragged  the earth  ground   conductor will be the last conductor to be  pulled from the connector block     5  Push the connector block  3  back into the  socket  ensure that it is orientated correctly  so that the sockets mate with the  corresponding pins labelled on the  electrical box  1      6  Gently pull on the cable to ensure that the  cable is trapped inside the connector  Tighten  the strain relief nut  6      7  Refit the sealing gland  2  over the socket  4   and push the socket onto the three connector  pins on the electrical box     8  Refit the retaining screw  5  and tighten     ensure that there is a slight compression of  the sealing gland     PVEK Valves PVEK Ventile Vannes PVEK    2         Electrical box  Sealing gland  Connector block  Electrical supply socket  Socket retaining screw  Cable strain relief nut     om bk    D      Position indicator socket    Elektrischer Schaltkasten  Dichtungsstopfbuchse  Klemmenblock  Elektrische Steckbuchse  Halteschraube f  r Buchse    oa Bonn    Zugentlastungsmutter f  r  Kabel  7  Buchse f  r Stellungsindikator    Coffret   lectrique  Presse   toupe d   tanch  it    Bloc connecteur    AO N    Prise femelle d alimentation    lectrique   Vis de fixation de prise   6  Ecrou de d  tente de c  ble  7  Prise femelle de l indicateur  de position       Figure 4   Electrical connectors  Abbildung 
28. in this manual     Read this manual before you install and operate  the valve  Important safety information is  highlighted as WARNING and CAUTION  instructions  you must obey these instructions   The use of WARNINGS and CAUTIONS is  defined below     WARNING  Warnings are given where failure to observe  the instruction could result in injury or death  to people     CAUTION  Cautions are given where failure to observe  the instruction could result in damage to the  equipment  associated equipment and  process        The units used throughout this manual conform  to the SI international system of units of  measurement     PVEK Valves PVEK Ventile Vannes PVEK    The following symbols appear on the PVEK  Valves     A  A    1 2 Description    Warning   refer to accompanying  documents     Warning   risk of electric shock     The PVEK valves are solenoid operated  vacuum valves which are compact and  lightweight  They are designed for low energy  consumption  low operating temperatures and  trouble free operation  The PVEK valve  enclosure provides protection to IP55  as defined  by EN60529      The valves are available in right angled and  in line versions  as shown in Figures 2 and 3    the in line valves are designated IPVEK valves   The valves are available with either stainless  steel or aluminium bodies and a range of  valve body and flange sizes is available to suit  your system  In external appearance  the various  models differ only in vacuum port configuration  and valve
29. ioxins or sodium azide   if YES  see Note 1  YES    e Provide proof of decontamination  Hazardous to human health and safety  YES    YOU MUST CONTACT BOC EDWARDS FOR ADVICE BEFORE  YOU RETURN SUCH EQUIPMENT             SECTION 3  LIST OF SUBSTANCES IN CONTACT WITH THE EQUIPMENT    Chemical Precautions required Action required after a spill     Substance name    Symbol  for example  use protective gloves  etc   leak or exposure                                  SECTION 4  RETURN INFORMATION    Reason for return and symptoms of malfunction          If you have a warranty claim    who did you buy the equipment from         e give the supplier   s invoice number       SECTION 5  DECLARATION    Print your name  Print your job title           Print your organisation           Print your address        Telephone number  Date of equipment delivery             have made reasonable enquiry and   have supplied accurate information in this Declaration    have not withheld    any information  and   have followed the Return of BOC Edwards Equipment   Procedure  HS1      Note  Please print out this form   sign it and return the signed    Signed  Date form as hard copy           P900 71 000 Issue K    P800 80 000 Issue J 01A09 010    UNITED KINGDOM    CORPORATE HEADQUARTERS  BOC EDWARDS   Manor Royal   Crawley   W est Sussex   RH10 9LW   Tel 44  1293 528844   Fax  44  1293 533453    BOC EDWARDS   W ingetes Industrial Estate  Great Bank Road  Westhoughton  Bolton  Lancashire   BLS 3SL   Tel  H
30. ition indicator has  changeover contacts and provides both normally  open and normally closed position indications   To use the reed switch position indicator   connect the terminals as described below     1  Undo the screw and remove the position  indicator socket  Figure 4  item 7  from the  electrical box  Remove the sealing gland   extract the connector block and loosen the  strain relief nut     2  Connect the signal cable to the terminals in  the connector block as shown in Figure 6   Refer to Table 2 for information on the  correct cable diameter  Do not use the  terminal marked with the earth  ground   symbol     3  Refit the connector block to the socket and  replace the socket  Note that the socket is not  polarised and can be fitted in any of four  possible positions  Ensure that the sockets  mate with the corresponding pins labelled on  the electrical box     PVEK Valves PVEK Ventile Vannes PVEK    24    E O N           Ne    gee Se  IN  os    Normally closed  Normally open  Common   Not used    NC  Offner   NO  Schlie  er   Masse   Nicht belegt    Normalement ferme  Normalement ouvert  Commun   Non utilise        lt   S   lt     Figure 6   Position indicator connections  Abbildung 6   Anschl  sse des Stellungsindikators  Figure 6   Branchements d   un indicateur de position    PVEK Valves PVEK Ventile Vannes PVEK    4 OPERATION    4 1 General  Once correctly installed  operation of the PVEK    valve is dependent only upon the switching of  the electrical supply t
31. me to open  ms   Offnungszeit  ms  40 40 60 80  Temps d ouverture  Time to close  ms   Schlie zeit  ms  100 100 100 120  Temps de fermeture  Mean time to failure  cycles   Mittlere Standzeit  Zyklen   gt  5 x 10    gt 5x10    gt  1 3 x 10    gt  1 3 x 10      Temps moyen avant apparition de d  faillances  MTTF                    Table 1   Performance  operating and storage conditions  continued   Tabelle 1   Leistungs   Betriebs  und Lagerbedingungen  Fortsetzung     Tableau 1   Performances  conditions de fonctionnement et de stockage  suite     PVEK Valves PVEK Ventile Vannes PVEK             PV10EK PV16EK PV25EK PV40EK                Electrical supply voltage range  Elektrischer Spannungsbereich  Plage de tension d   alimentation       110 V nominal 110 V Nennspannung 110 V nominale 90   132 V  240 V nominal 240 V Nennspannung 240 V nominale 180   264 V  Frequency  Frequenz Frequence 50   60 Hz  Continuous power  W  Dauerleistung  W   Puissance continue  W   110 V ae 3 3 3 3 6 1 8 0  240 V a c  4 4 4 4 8 2 8 3       Peak power  VA  for 60 ms Spitzenleistung  VA  f  r 60 ms    Puissance de pointe  VA  pour 60 ms  110 V a c  450 450 940 1400  240 V a c  560 560 1200 2400                Reed switch ratings   Daten Zungenschalter   Caract  ristiques nominales de commutateur    lame vibrante  Maximum voltage  peak  a c  or d c    Maximalspannung  Spitzenwert  Wechselstrom oder Gleichstrom  28 V  Tension maximale  pointe  c a ou c c    Maximum current  peak   power  r m s    Max
32. mped in your system  For    clean     systems  we recommend that you use Fomblin     Refer to Figure 7 for item numbers shown in  brackets     1  Isolate the valve from the electrical supply     2  Undo the four retaining screws  9  and  remove the valve body  11  and the  valve body    O    ring  10  from the valve     3  Examine the bellows pole piece assembly   7   the valve body   O    ring  10  and the  valve pad   O    ring  12  for damage and wear     4  If necessary  replace any worn or damaged  items as described in Sections 5 3 and 5 4     5  Refit the bellows assembly into the  actuator case  ensure free movement of the  pole piece in the actuator case     6  Refit the valve body  11  to the valve  secure  in place with the four retaining screws  9   and a suitable locking adhesive such as  Locktite 222     PVEK Valves PVEK Ventile Vannes PVEK     gt     Detail of in line valve    Electrical box   Top cap   Sorbathane pad   Bearing assembly   Fixed pole   Coil   Bellows pole piece assembly  Actuator housing    SS  d e D Gs Se D      SS    Retaining screw  10  Valve body    O    ring  11  Valve body   12  Valve pad    O    ring    30     gt     SSC St OS Sy  gt     wo    10   11   12     Detaildarstellung des Durchgangsventils    Elektrischer Schaltkasten  Haube   Sorbathan Kissen  Lagerbaugruppe   Festes Polst  ck   Spule  Faltenbalg  Polst  ckgruppe  Stellgliedgeh  use  Halteschraube   O Ring des Ventilk  rpers  Ventilk  rper   O Ring des Ventiltellers    Figure 7
33. n  A magnetic reed switch  positioned on the underside of the PCB provides  position indication  The reed switch has  changeover contacts and provides both normally  open and normally closed position indications     1 3    Die  Nur  PVE    Der  elek  mit    Falt  dur  Fluc  Edel  von  dich  Fluc  Der  Flan    Eine  Sch   Ein   Unt  Stell    als      14 Operation    The solenoid coil in the valve has two windings   To open the valve  both windings are energised   Initially  the inner high energy or pulse winding  provides a high transient force to open the valve  and is then de energised  The outer low energy  or    hold    winding remains energised to maintain  the valve in the open position with minimum  power     The valve is closed by de energising the solenoid  coil  When the outer winding is de energised   the action of the spring provides rapid positive  closure     PVEK Valves PVEK Ventile Vannes PVEK    1 4    Die  Wi  bei    ein  Vel  nie  err  Str    ele  We  die  Sch    2 TECHNICAL DATA    Note  Unless otherwise specified  all data in this  section refers to both right angled and in line valves     2 1 Mechanical data  Refer to Table 3     2 2 Performance  operating and  storage conditions    Refer to Table 1     2 3 Electrical data  Refer to Table 2     24 Materials    The valves are manufactured from the following  materials     Valve body   PVEKA Valve HESOTF grade  aluminium   PVEKS Valve AISI 304 grade  stainless steel   Bellows AISI 316L  stainless steel     
34. n  HS2      3  Ifthe equipment is contaminated  you must contact your transporter to ensure that you properly classify the hazard  mark  manifest and ship the equipment  in accordance  with applicable laws governing the shipment of contaminated hazardous materials  As the person offering the equipment for shipment  it is your responsibility to ensure  compliance with applicable law  Note  Equipment contaminated with some hazardous materials  such as semiconductor by products  may not be suitable  for airfreight   contact your transporter for advice     4  Remove all traces of hazardous gases  pass an inert gas through the equipment and any accessories that will be returned to BOC Edwards  Where possible  drain all fluids  and lubricants from the equipment and its accessories     5  Seal up all of the equipment s inlets and outlets  including those where accessories were attached  with blanking flanges or  for uncontaminated product  with heavy gauge  tape     Seal equipment in a thick polythene polyethylene bag or sheet    If the equipment is large  strap the equipment and its accessories to a wooden pallet  If the equipment is too small to be strapped to a pallet  pack it in a suitable strong box   Fax or post a copy of the Declaration  HS2  to BOC Edwards  The Declaration must arrive before the equipment    Give a copy of the Declaration  HS2  to the transporter  You must tell your transporter if the equipment is contaminated       90 oo N Ss    oO    Seal the original Decl
35. nal or international transportation safety or environmental requirements  As the person offering the equipment for  shipment  it is your responsibility to ensure compliance with applicable laws     GUIDELINES  e Equipment is  uncontaminated  if it has not been used  or if it has only been used with substances that are not hazardous  Your equipment is    contaminated  if it has  been used with any substances classified as hazardous under EU Directive 67 548 EEC  as amended  or OSHA Occupational Safety  29 CFR 1910      e If your equipment has been used with radioactive substances  biological or infectious agents  mercury  polychlorinated biphenyls  PCB   s   dioxins or sodium azide  you must  decontaminate it before you return it to BOC Edwards  You must send independent proof of decontamination  for example a certificate of analysis  to BOC Edwards  with the Declaration  HS2   Phone BOC Edwards for advice     e If your equipment is contaminated  you must either   e Remove all traces of contamination  to the satisfaction of laws governing the transportation of dangerous hazardous substances    e _ Or  properly classify the hazard  mark  manifest and ship the equipment in accordance with applicable laws governing the shipment of hazardous materials   Note  Some contaminated equipment may not be suitable for airfreight     PROCEDURE    1  Contact BOC Edwards and obtain a Return Authorisation Number for your equipment   2  Complete the Return of BOC Edwards Equipment   Declaratio
36. o the valve     4 2 Position indicator    WARNING  Do not use the position indicator as a safety    interlock device  Under certain circumstances  the position indicator may not operate  correctly        Do not rely entirely on the position indicator to  indicate the state of the valve for the following  reasons     In the event of low electrical supply voltage  or a temporary loss of the electrical supply to  the valve  it is possible for the valve to close  but the position indicator to show the valve  still open  This is because the stray magnetic  flux which remains during a temporary loss  of the electrical supply could be sufficient to  hold the reed switch    open        If the valve is not able to close due to a  physical obstruction  the position indicator  will show the valve to be closed     PVEK Valves PVEK Ventile Vannes PVEK    na  fh A    If it is essential to know the state of the valve for  safety reasons  use additional indicators  such as  pressure gauges in the pipelines on each side of   the valve     26    5 MAINTENANCE    5 1 General  PVEK valves do not require routine maintenance    during their normal operational life  If the valve  is faulty  refer to the following sections     5 1 1 Safety information    WARNING  Obey the safety instructions given below and    take note of appropriate precautions  If you  do not you can cause injury to people and  damage to equipment        Ensure that maintenance is done by a  suitably trained and supervised techni
37. re 3   In line valve dimensions  Abbildung 3   Abmessungen der Durchgangsventile  Figure 3   Dimensions de la vanne a passage direct    PVEK Valves PVEK Ventile Vannes PVEK       13    2 6 Product Item Numbers 2 6    14    2 6 1 Right angled valves 2 6    Product Item Number Proc  Alur  Aluminium bodies P  PV10EKA Valve  220 V  C411 01 000 P  PV10EKA Valve  110 V  C411 03 000 P  PV16EKA Valve  220 V  C412 01 000 P  PV16EKA Valve  110 V  C412 03 000 P  PV25EKA Valve  220 V  C413 01 000 P  PV25EKA Valve  110 V  C413 03 000 P  PV40EKA Valve  220 V  C414 01 000 P  PV40EKA Valve  110 V  C414 03 000 Edel  Stainless steel bodies P  PV16EKS Valve  220 V  C412 02 000 P  PV16EKS Valve  110 V  C412 04 000 P  PV25EKS Valve  220 V  C413 02 000 P  PV25EKS Valve  110 V  C413 04 000 E  PV40EKS Valve  220 V  C414 02 000 P  PV40EKS Valve  110 V  C414 04 000    2 6 2 In line valves    PVEK Valves PVEK Ventile Vannes PVEK    Product Item Number   Aluminium bodies  PV10EKA Valve  220 V     PV10EKA Valve  110 V     PV16EKA Valve  220 V  C416 10 000  PV16EKA Valve  110 V  C416 11 000  PV25EKA Valve  220 V  C416 30 000  PV25EKA Valve  110 V  C416 31 000  PV40EKA Valve  220 V  C416 51 000  PV40EKA Valve  110 V  C416 52 000   Stainless steel bodies  PV16EKS Valve  220 V  C416 12 000  PV16EKS Valve  110 V  C416 13 000  PV25EKS Valve  220 V  C416 32 000  PV25EKS Valve  110 V  C416 33 000  PV40EKS Valve  220 V  C416 53 000  PV40EKS Valve  110 V  C416 54 000    3 INSTALLATION    3 1 Unpack and inspect    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
StarTech.com Professional USB VGA Multi Monitor Video Adapter  HemoCue AG-Hofstrasse 105-8620 Wetzikon  Internet and Intranet Calling with Polycom PVX  MANUALE DI INSTALLAZIONE E PROGRAMMAZIONE  IDXPERT USER MANUAL  EVOLUTION 1  HX16-Rev1.0 Manual  Lian Li PC-Z60B computer case  スーパーロボット超合金 グレンラガン 取扱説明書 540.7 KB  Samsung CC03 User Manual    Copyright © All rights reserved. 