Home
Montageanleitung Zanier E2
Contents
1. TYPE BC45 BC45E BC60 BC60E Als Make sure the clip fastens in the hole properly Versichere dass die Befestigungs Osen richtig daf r vorgesehene Aufh ngung sitzen The right or left handedness of the heater can be changed by installing it to the wall mount correspondingly Der Saunaofen kann zur Bedienung durch Rechts oder Linksh nder unterschiedlich an der Wand montiert werden max 500 mm Figure 7 Abbildung 7 Fastening the Heater on a Wall Befestigung des Saunaofens an der Wand sauna room above the heater It should be installed on the lateral centre line of the heater 100 mm down wards from the ceiling 3 6 Electrical Connections The heater may only be connected to the electrical network in accordance with the current regulations by an authorised professional electrician The cross section area of the wires connected from the heater to the heating control and signal light must be equal to that of the supply cable of the heater The heater is semistationarily connected to the junction box on the sauna wall See fig 8 The connection cable must be of rubber cable type HO7RN F or its equivalent NOTE Due to thermal embrittlement the use of PVC insulated wire as the connection cable of the heater is forbidden The junction box must be splash proof and its maximum height from the floor m
2. 10 EN If the heater is mounted ready made sauna the instructions of the sauna manufacturer should be followed when arranging ventilation The series of pictures shows examples of ventilation systems for a sauna room See fig 4 2 5 Hygienic Conditions of the Sauna Room Good hygienic standards of the sauna room will make bathing a pleasant experience The use of sauna seat towels is recommended to prevent sweat from flowing onto the platforms The towels should be washed after each use Separate towels should be provided for guests It is advisable to vacuum or sweep the floor of the sauna room in connection with cleaning In addition the floor may be wiped with a damp cloth The sauna room should be thoroughly washed at least every six months Brush the walls platforms and floor by using a scrubbing brush and sauna cleanser Wipe dust and dirt from the heater with a damp cloth 3 INSTRUCTIONS FOR INSTALLATION 3 1 Prior to Installation Prior to installing the heater study the instructions for installation as well as checking the following points e 5 the output and type of the heater suitable for the sauna room The cubic volumes given in table 1 should be followed e 5 for the mounting place the heater is right handed e Are there a sufficient number of high quality sauna stones e Is the supply voltage suitable for the heater e f the house is heated by electricity does the pilot circui
3. 4 gt N 1 213 415 AG 11 GRD POWER SUPPLY HAUPTZENTRALE 230V 240V IN CONNECTION CABLE CONNECTION Ge ANSCHLURKABEL CX JUNCTION BOX KLEMMDOSE SWITCH FOR ALL POLE DISCONNECTION SCHALTER FUR ALLPOLIGER ABSCHALTUNG Single phase electrical connections 230V Einphasiger Elektroanschl sse 230V DE BC45 80 L e gt 3 112137115186 POWER SUPPLY HAUPTZENTRALI SICHERUNGEN 240V 415V 3N 230V 400V 3N CONNECTION CABLE ANSCHLURKABEL JUNCTION BOX KLEMMDOSE 3 phase electrical connections 400V 3 phasiger Elektroanschl sse 400V A B P D mm2 mm2 mm2 mm2 BC45 BC45E 3x4 1x 20A 3x2 5 5x 1 5 3x 10A 5 1 5 BEGO BCGOEM 10 185 9506 915 BC80 BC80E 10 1x BbBA 3x6 5 2 5 16 5x 1 5 e IS 10 15 T 85068 15 Table 2 m Tabelle 2 L 12 GRD POWER SUPPLY CONNECTION CABLE HAUPTZENTRALE os ANSCHLURKABEL 230V 240V 3 EA JUNCTION BOX KLEMMDOSE SWITCH FOR ALL POLE DISCONNECTION SCHALTER F R ALLPOLIGER ABSCHALTUN
4. In einer Sauna darf nur ein Saunaofen installiert werden 3 2 Befestigung des Saunaofens an der Wand 1 Befestigen Sie das Montagegestell mit den dazu gelieferten Schrauben an der Wand und beachten Sie die in Abb 5 und 6 und in Tabelle 1 angef hrten Sicherheitsmindestabst nde ACHTUNG An den Stellen an denen die Befestigungsschrauben angebracht werden muss sich hinter den Paneelen als St tze z B ein Brett befinden in dem die Schrauben fest sitzen Falls sich hinter den Paneelen keine Bretter befinden k nnen diese auch vor den Paneelen angebracht werden 2 Heben Sie den Saunaofen so auf das Gestell an der Wand da die Befestigungshaken unten am Gestell hinter den Rand des Saunaofenrumpfes kommen 3 Schrauben Sie den oberen Rand des Saunaofens am Montagegestell fest 3 3 Installation des Saunaofens in einer Nische Der Saunaofen kann in einer Wandnische angebracht werden deren H he min 1900 mm betr gt Siehe Abb 6 3 4 Schutzgel nder Falls um den Saunaofen ein Schutzgel nder gebaut wird mu dies unter Ber cksichtigung der in Abb 5 und Tabelle angegebenen Mindestsicherheits abst nde geschehen 3 5 Anschlu des Steuerger tes C90 C150 und der F hler BC45E BC60E BC80E BC9OE Das Steuerger t wird in einem trockenen Raum au erhalb der Saunakabine in etwa 170 cm H he angebracht In Verbindung mit dem Steuerger t werden genauere Anweisungen zu dessen Befestigung an der Wand gegeben EN DE
5. der Uhrschalter auf die gew nschte Nummer im Funktionsbereich 0 4 eingestellt werden Somit schaltet sich der Saunaofen sofort ein die Sauna erw rmt sich und ist in etwa einer Stunde f r den Badenden bereit Der Saunaofen sollte gleich ausgeschaltet werden nachdem das Saunen beendet wurde und die Sauna ofensteine getrocknet sind Manchmal ist es jedoch erforderlich den Ofen f r eine kurze Zeit eingeschaltet zu lassen damit die Holzteile der Sauna trocknen ACHTUNG Es ist darauf zu achten da der Uhrschalter der Sauna die Widerstandsstr me des Saunaofens nach der eingestellten Zeit ausgeschaltet hat Thermostat and Overheating Limiter The thermostat consists of two units the adjustable unit aims to keep the temperature of the sauna room stable The temperature is adjusted by the thermostat to a position between minimum and maximum The correct position of the thermostat switch is found by experimenting Begin experimenting at the maximum position far right to find how quickly Thermostat und berhitzungsschutz Das Thermostat besteht aus zwei Funktionseinheiten von denen die regelbare Einheit bestrebt ist die ein gestellte Temperatur in der Saunakabine stabil zu halten Die Einregelung der Temperatur geschieht durch Einstellen des Thermostats zwischen Minimum und Maximun Die richtige Einstellposition des Thermostats mu durch Probieren herausgefunden werden the sauna room and stones can be
6. heated to the desired temperature If during bathing the temperature seems to be becoming too high turn it down a little by turning the switch counter clockwise It must be noted that even a small difference within the maximum section will change the temperature of the sauna considerably See fig 3 If for some reason the temperature of the sauna room becomes too high the overheating limiter of the thermostat will permanently cut off the supply of the resistances The overheating limiter cannot be reset to the position allowing electricity into the thermostat until the heater has cooled down The overheating limiter is reset by pressing the reset button of the thermostat which is located in the connection box inside the heater Only persons authorised to carry out electrical installations can reset the overheating limiter See item 3 6 1 and fig 12 Prior to pressing the button the cause of the fault must be found e the stones crumbled and pressed together e has the heater been on for a long time while unused e is the sensor support of the thermostat bent Figure 3 Abbildung 3 Thermostat Thermostat Beginnen Sie die Probe mit der maximalen Einstellposition des Reglers rechter Anschlag so erfahren Sie wie lange der Saunaofen mindestens braucht um die Sauna und die Saunaofensteine auf die gew nschte Temperatur zu erw rmen Falls die Temperatur w hrend des Saunens zu hoch ansteigt mu der Regler d
7. 5 und 6 0 kW Saunaofens Electrical connections of BCE heater Abbildung 10b Elektroanschl sse des Saunaofens BCE Figure 10b C150 Figure 11a Single phase electrical connections of BC45E and BC60E heater Abbildung 11a Einphasiger Elektroanschl sse des BC45E und 16 6 Saunaofens EN DE BC9OE CONTROL UNIT HEATER BC80E STEUERGERAT C90 SAUNAOFEN BC60E POWER SUPPLY HAUPTZENTRALE HEATER SAUNAOFEN 400V 230V 3N CONTROL OF HEATING STEUERUNG DES ERHITZENS 4 x 0 5 mm SENSOR FUHLER N L1 1213 05 5 SICHERUNGEN JUNCTION BOX VERTEILERDOSE Figure 11b 3 phase electrical connections of control unit C150 and BCE heater Abbildung 11b 3 phasiger Elektroanschl sse das Steuerger t C150 und des Saunaofens BCE Figure 12 Reset button for overheating limiter Abbildung 12 R cksetzknopf des berhitzungsschutzes K1 he 4 I FE CONTROL OF HEATING S STEUERUNG ale DES ERHITZENS 4 x 0 5 mm 59 iene LICHT max 100 W 2 SIGNAL LIGHT KONTROLLAMPE max 100W POWER SUPPLY HAUPTZENTRALE HEN b b ww HEATER 400V 230V 3N SAUNAOFEN SENSOR F HLER 0 111213 SHMEE SICHERUNGEN NEEE 5 JUNCTION BOX KLEMMDOSE Figure 11c 3 phase electrical connections of control unit C90 and BCE heater Abbildung 11b 3 phasiger Ele
8. are located in the sensor box The temperature is sensed by an NTC thermistor and there is an overheating limiter that can be reset In case of malfunction this overheating limiter will cut off the heater power permanently The control unit must be installed in a dry area for example the dressing room whereas the thermostat must be installed in the sauna room above the heater close to the ceiling For further instructions see the instructions for installation of the control unit 1 4 Throwing Water on Heated Stones The air in the sauna room becomes dry when warmed up Therefore it is necessary to throw water on the heated stones to reach a suitable level of humidity in the sauna The humidity of the air in the sauna room is controlled by the amount of water thrown on the stones A correct level of humidity makes the bather s skin sweat and makes breathing easy By throwing water on the stones with a small ladle the bather should feel the effect of air humidity on his skin Both too high a temperature and air humidity will give an unpleasant feeling Staying in the hot sauna for long periods of time makes the body temperature rise which may be dangerous The maximum volume of the ladle is 2 decilitres The amount of water thrown on the stones at a time should not exceed 2 dl because if an excessive amount of water is poured on the stones only part of it will evaporate and the rest may splash as boiling hot water on the bather
9. thicker wooden material than the panel If there are no boards behind the panel the boards can also be fastened on the panel 2 Lift the heater to the rack on the wall so that the fastening hooks of the lower part of the rack go behind the edge of the heater body 3 Lock the edge of the heater onto the fastening rack by a screw 3 3 Installation of the Heater in a Recess The heater can be mounted in a recess with a minimum height of 1900 millimetres See fig 6 3 4 Safety Railing If a safety railing is built around the heater the minimum distances given in fig 5 and table 1 must be observed 3 5 Installation of the control unit C90 C150 and sensors BC45E BC60E BC80E BC9OE Install the control unit in a dry place outside the sauna room at the height of about 170 cm The control unit includes detailed instructions for fastening the unit on the wall Install the temperature sensor on the wall of the 12 Safety distances from the heater Abbildung 5 Sicherheitsmindest abst nde des Saunaofens Installation of the heater in a recess Abbildung 6 Montage des Saunaofens in einer Wandnische Figure 6 potentialfrei zu stellen da vom Saunaofen bei Gebrauch eine Spannungssteuerung Ubertragen wird e Der Montageort des Ofens erf llt die in Abbildung 5 und 6 und Tabelle 1 angegebenen Sicherheitsmindestabstande Diese Abstande miissen unbedingt eingehalten werden da ein Abweichen Brandgefahr verursacht
10. G 3 phase electrical connections 230V 3 phasiger Elektroanschl sse 230V Figure 9 Electrical connections of the heater Abbildung 9 Elektroanschl sse des Saunaofens 15 EN 3 7 Electric heater insulation resistance When performing the final inspection of the electrical installations a leakage may be detected when measuring the heater s insulation resistance The reason for this is that the insulating material of the heating resistors has absorbed moisture from the air storage transport After operating the heater for a few times the moisture will be removed from the resistors Do not connect the power feed for the heater through the RCD residual current device DE 3 7 lsolationswiderstand des Elektrosaunaofens Bei der Endkontrolle der Elektroinstallationen kann bei der Messung des Isolationswiderstandes ein Leck auftreten was darauf zur ckzuf hren ist da Feuchtigkeit aus der Luft in das Isolationsmaterial der Heizwiderst nde eingetreten ist bei Lagerung und Transport Die Feuchtigkeit entweicht aus den Widerst nden nach zwei Erw rmungen Schalten Sie den Netzstrom des Elektrosaunaofens nicht ber den Fehlerstromschalter ein BC45E BC60E BC45E BC6OE BC80E BCA45E BC9OE De 400V 3N Figure 10a Electrical connections of 4 5 and 6 0 kW heater Abbildung 10a Elektroanschl sse des 4
11. OE 9 0 8 14 1900 120 40 100 1100 80 5x25 3x16 Table 1 Installation details of a BC BCE heater Tabelle 1 Montageinformationen zum BC BCE Saunaofen X To thermostat 4 x 0 5 mm An Thermostat 4 x 0 5 mm 11 EN DE A NONCNCN NON SANNA N N N N N N ES N N B TYPE A min mm N ECJ BC45 BC45E 35 E N L N BC60 BC60E 50 N N BC80 BC80E 100 1 max 500 mm N mak 500 mm Y lt gt 120 cN Figure 5 control is transmitted from the heater when it is switched on e location of the heater fulfils the minimum requirements concerning safety distances given in fig 5 and 6 and table 1 It is absolutely necessary to ensure that the installation is carried out according to these values Neglecting them can cause a risk of fire Only one electrical heater may be installed in the sauna room 3 2 Fastening the Heater on a Wall 1 Fasten the wall mounting rack on the wall by using the screws which come with the rack Observe the minimum safety distances given in table 1 and fig 5 and 6 NOTE There must be a support e g a board behind the panel so that the fastening screws can be screwed into a
12. Piling of the Sauna Stones 3 1 1 Aufschichten der Saunaofensteine 3 1 gt Heating of the 4 1 2 Erhitzen der Saunakabine 4 1 3 Controls and use of the heater 4 1 3 Schaltmechanismus und Anwendung des 1 3 1 Heaters with timer and en le TEE A thermostat BC45 BC60 BC80 BC90 4 1 3 2 Heaters with separate control units 1 3 1 Ofen mit Schaltuhr und Thermostat BC45 BC60 BC80 BC90 4 BC45E BC60E BC80E BC9OE 6 1 3 2 Ofen mit separatem Steuergerat 1 4 Throwing Water on Heated Stones 6 BC45E BC60E BC80E 9 6 1 4 1 Sauna Water rn racers 6 n te UE 6 1 4 2 Temperature Humidity of the 1 4 1 Aufgu wasser 6 Salina ROOM inet 7 1 4 2 Temperatur und Feuchtigkeit in 1 5 Instructions for Bathing 7 der Sa riakabiti u uuu dee 7 UR OCL Une E 7 1 5 Anleitungen zum 7 1 7 Troubleshooting rre 8 1 6 nennen 7 US Gd ele Dr EE 8 2 THE SAUNA 8 2 SAUNAKABINE 8 2 1 Insulation and Wall Materials of the 2 1 Isolation der Saunakabine und Sauna ROOM EE 8 Wanpndmat rIall fs uu isn 8 2 1 1 Black
13. ZANIER Premium Fitness Company A 9990 Debant Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at Montage und Bedienungsanleitung ZANIER f r das Modell Finnische Sauna 2 Seite 1 ZANIER Premium Fitness Company A 9990 Debant Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at Inhaltsverzeichnis Einleitung E 2 N tzungsbedingungen au ee 3 stlecher 3 ur Ex ERE RE ea cing eege 3 Benotigtes Werkzele serere deen deve se Ee S ERE RAF rH Vae eue eae Peu 4 Tu LTE 9 Service und Kontakttelefonnummern arva an cer kb ou add ANE Fa e der 9 Installation und Bedienung des Saunaofens EEN 10 EINLEITUNG Herzliche Gratulation zum Erwerb einer ZANIER Sauna Sie haben ein Produkt mit einem sehr guten Preis Leistungsverh ltnis erworben Unsere langj hrige Erfahrung im Bereich Wellness Fitness Gesundheits aber auch Hochleistungssport und die umfangreichen R ckmeldungen unserer Kunden sind Anlass f r die permanente Weiterentwicklung unserer Produkte ZANIER Saunen werden nach den strengen ISO 9001 Qualitatsrichtlinien produziert und unterliegen damit einer intensiven Qualit tssicherung Entscheidend f r unsere Kunden ist eine hervorragende Wirksamkeit und Zuverl ssigkeit f r lange Jahre F r Ihr gesundes Wohlbefinden Seite 2 ZANIER Premium Fitness Company A 9990 Deban
14. ZANIER Premium Fitness Company A 9990 Debant Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at Anschrauben der Sitzbank Nun befestigen Sie noch die R ckenlehne an der R ckwand R ckenlehne anbringen Seite 8 ZANIER Premium Fitness Company A 9990 Debant Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at Endreinigung Ihre Sauna muss jetzt nur noch mit einem feuchten Tuch und bei den Glasflachen mit Fensterputzmittel gereinigt werden und kann dann schon in Betrieb genommen werden Reinigung Reinigen Sie das u ere der Kabine mit einem feuchten Tuch oder mit einer geringen Menge Seife mit warmem Wasser wenn n tig Reinigen Sie den Innenraum mit einem feuchten Baumwolltuch trocknen Sie ihn mit einem sauberen trockenen Tuch Verwenden Sie kein Benzin Alkohol oder starke Reinigungschemikalien in der Sauna ACHTUNG Jede verwendete Chemikalie die das Holz sch digt sch digt auch die Kabine und zerst rt die Schutzschicht mit der das Holz versehen ist Transport und Lagerung Setzen Sie die Kabine w hrend des Transports keinem Regen Schnee oder heftigen Kollisionen aus Lagern Sie sie nicht in einer feuchten Umgebung Gr nde bei denen Sie die Sauna nicht benutzen sollten Falls Sie offene Wunden haben Falls Sie eine Augenkrankheit haben Falls sie schwere Sonnenbr nde haben Alten und gebrechlichen Menschen Menschen die an ein
15. arauf dass die beiden Wandteile richtig zusammengestellt wurden Wenn die Schnappverschl ssel sich nicht leicht schlie en lassen stimmt die Ausrichtung der Seitenteile noch nicht Dieselben Arbeitsschritte wiederholen Sie auch mit dem 2 Seitenteil und mit dem Frontteil Bodenplatte Seite 4 ZANIER Premium Fitness Company A 9990 Debant Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at 1 Seitenwand Seite 5 ZANIER Premium Fitness Company A 9990 Debant Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at 2 Seitenwand Schnappverschl sse Links offen Rechts geschlossen Frontseite mit T r Seite 6 ZANIER Premium Fitness Company A 9990 Debant Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at Im n chsten Schritt legen Sie das Deckenpaneel auf die Sauna Achten Sie bitte darauf dass Sie keine Kabel klemmen oder besch digen Stellen Sie sicher dass der Deckel vollfl chig aufliegt und die Ecken geschlossen sind Der Deckel wird mit Schrauben fixiert Anbringen des Deckenpaneels Danach bauen Sie die Sitzbank ein Stecken Sie erst das vertikale Paneel in die daf r vorgesehene F hrung danach legen Sie die Sitzbank auf das vertikale Paneel und auf die Leisten Zum Fixieren schrauben Sie die Sitzbank bitte an a Mb 24 C Laia Anbringen der Sitzbank Seite 7
16. ce causes the cubic volume of the sauna to increase by 1 2 m The heater output is then selected according to the values given in the table Because log walls are heated slowly the cubic volume of a log sauna should be multiplied by 1 5 and the heater output should then be selected on the basis of this information 2 4 Ventilation of the Sauna Room Sufficient ventilation is extremely important for the sauna The air in the sauna room should be changed six times per hour The fresh air pipe should come directly from outside According to the newest research results the pipe should be located at a minimum height of 50 cm above the heater The pipe diameter should be about 5 10 cm Exhaust air should be led from the lower part of the sauna directly into the air chimney or by using an exhaust pipe starting near the floor level into a vent in the upper part of the sauna Exhaust air can also be led out through an exhaust air vent in the washing room through a 5 cm opening under the sauna door The exhaust air of the sauna room should be taken from as far from the heater as possible but near the floor level The crosscut area of the exhaust air vent should be twice that of the supply air pipe For the above mentioned system mechanical ventilation is necessary Ventilation of the sauna room Ventilation in der Saunakabine Figure 4 Abbildung 4 DE 2 3 Leistung des Saunaofens Wenn die W nde und die Decke get felt sind u
17. d rfte gen gen e Bleiben Sie dann der Sauna solange Sie es als angenehm empfinden e Zu guten Saunamanieren geh rt da Sie R cksicht auf die anderen Badenden nehmen indem Sie diese nicht mit unn tig l rmigem Benehmen st ren e Verjagen Sie die anderen auch nicht mit zu vielen Aufg ssen e Vergessen Sie jeglichen Stre und entspannen Sie sich e Lassen Sie Ihre erhitzte Haut zwischendurch abk hlen e Falls Sie gesund sind und die M glichkeit dazu besteht gehen Sie auch schwimmen e Waschen Sie sich nach dem Saunen Nehmen Sie zur R ckgewinnung der verlorenen Fl ssigkeit ein erfrischendes Getr nk zu sich e Sie sich aus bis Sie sich ausgeglichen f hlen und ziehen Sie sich an 1 6 Warnungen e Meer und feuchtes Klima k nnen die Metalloberfl chen des Saunaofens rosten lassen e Benutzen Sie die Sauna wegen der Brandgefahr nicht zum Kleider oder W schetrocknen au erdem k nnen die Elektroger te durch die 7 EN equipment e Keep away from the heater when it is hot The stones and outer surface of the heater may burn your skin e Do not throw too much water on the stones The evaporating water is boiling hot e Do not let young handicapped or ill people bathe in the sauna on their own e Consult your doctor about any health related limitations to bathing e Parents should keep children away from the hot heater e Consult your child welfare clinic about taking little babie
18. e equipped with a timer and a thermostat on the upper part of the heater The BC45E 6 BC80E and BC9OE heaters must be equipped with a separate control unit which must be installed in a dry area outside of the sauna room Before you switch the heater on check always that there aren t any things over the heater or in the near distance of the heater See item 1 6 Warnings 1 3 1 Heaters with timer and thermostat BC45 BC60 BC80 BC90 Timer The heater is switched on by using the timer switch The timer has two scales the first one with larger figures is the instantly on section that is the heater is on for a selected period of time 4 hours The other section is the so called pre DE 1 2 Erhitzen der Saunakabine Beim ersten Erwarmen sondern sich von Saunaofen und Steinen Ger che ab Um diese zu entfernen mu die Saunakabine gr ndlich gel ftet werden Die Funktion des Saunaofens ist es die Saunakabine und die Ofensteine auf die Aufgu temperatur zu bringen Wenn die Leistung des Saunaofens an die Gr e der Saunakabine angepa t ist erw rmt sich eine gut w rmeisolierte Sauna auf Aufgu temperatur in etwa einer Stunde Siehe Kapitel 2 1 Isolation der Saunakabine und Wandmaterialien Die passende Temperatur in der Saunakabine betr gt etwa 65 C bis 80 C Die Saunaofensteine erw rmen sich auf Aufgu temperatur gew hnlich in derselben Zeit wie die Saunakabine Ein zu l
19. e beginnen Durch die st ndige Weiterentwicklung unserer Produkte kann es in der Anleitung zu geringf gigen Abweichungen kommen Sollten Sie w hrend der Montage Schwierigkeiten haben oder sollten Fragen auftreten setzten Sie sich bitte mit uns in Verbindung Das Auspacken und erste Montageschritte Legen Sie die Kartons auf eine ebene Fl che und achten Sie darauf dass der Kartondeckel oben ist Nehmen Sie dann Teil f r Teil vorsichtig aus dem Karton und lagern Sie die einzelnen Bauteile schr g an eine Wand gelehnt Legen Sie zwischen Wand und Holzteil etwas zum Oberfl chenschutz bei Ben tigtes Werkzeug Seite 3 ZANIER Premium Fitness Company A 9990 Debant Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at F r den Aufbau ben tigen Sie nur sehr wenig Werkzeug Einen Kreuzschraubenzieher und einen TORX 10 Schraubendreher oder einen Akkuschrauber mit dem entsprechenden Einsatz Verbindung der R cken und Seitenwandpaneele mit dem Bodenpaneel Legen Sie nun die Bodenplatte in die N he des sp teren Verwendungsortes und lassen Sie f r die weitere Montage mindestens 30cm Raum zur Wand Bringen Sie nun die R ckwand in die entsprechende Position Eine Person h lt dann die R ckwand und die zweite Person stellt die erste Seitenwand dazu Achten Sie auf die richtige Ausrichtung links rechts oben unten Verbinden Sie die die beiden Teile mit den Schnappverschl ssen Achten Sie bitte d
20. e heater is switched on for the first time both the heater and the stones emit smell To remove the smell the sauna room needs to be efficiently ventilated The purpose of the heater is to raise the temperature of the sauna room and the sauna stones to the required bathing temperature If the heater output is suitable for the sauna room it will take about an hour for a properly insulated sauna to reach that temperature See item 2 1 Insulation and Wall Materials of the Sauna Room A suitable temperature for the sauna room is about 65 C 80 C The sauna stones normally reach the required bathing temperature at the same time as the sauna room If the heater capacity is too big the air in the sauna will heat very quickly whereas the temperature of the stones may remain insufficient consequently the water thrown on the stones will run through On the other hand if the heater capacity is too low for the sauna room the room will heat slowly and by throwing water on the stones the bather may try to raise the temperature of the sauna However the water will only cool down the stones quickly and after a while the sauna will not be warm enough and the heater will not be able to provide enough heat In order to make bathing enjoyable the heater capacity should be carefully chosen to suit the size of the sauna room See item 2 3 Heater Output 1 3 Controls and use of the heater The BC45 BC60 BC80 and BC90 heaters ar
21. eistungsstarker Saunaofen erw rmt die Saunaluft schnell aber die Steine bleiben untererhitzt und lassen so das Aufgu wasser durchflie en Wenn andererseits die Saunaofenleistung in Bezug auf die Gr e der Saunakabine gering ist erw rmt sich die Saunakabine langsam und der Saunabader wird versuchen die Saunatemperatur durch einen Aufgu durch Gie en von Wasser auf den Saunaofen zu erh hen Das Aufgu wasser k hlt aber nur die Saunaofensteine schnell ab und nach einer Weile reicht die Temperatur in der Sauna nicht mehr f r einen Aufgu aus Damit Sie beim Saunen die Aufg sse genie en k nnen sollten Sie die Leistung des Saunaofens in Bezug auf die Saunakabine anhand der Brosch ren informationen sorgf ltig ausw hlen Siehe Kapitel 2 3 Leistung des Saunaofens 1 3 Schaltmechanismus und Anwendung des Saunaofens Die Typen BC45 BC60 BC80 und 90 sind mit einer Uhrschalter und einem Thermostat ausgestattet Die Typen BC45E 6 BC80E und BC9OE werden mit einem separaten Steuerger t bedient das au erhalb der Saunakabine an einem trockenen Ort angebracht werden soll Bevor Sie den Ofen anschalten bitte berpr fen dass keine Gegenst nde auf dem Ofen oder in der unmittelbarer Nahe des Ofens liegen Siehe Kapitel 1 6 Warnungen 1 3 1 fen mit Schaltuhr und Thermostat 45 BC60 BC80 90 Uhrschalter Der Saunaofen wird durch das Drehen des Uhrschalters angeschaltet Die Skala des Uhr
22. ening of the sauna walls 9 2 1 1 Verf rbung der Saunaw nde 9 2 2 Sauna ROOM 0 9 2 2 Fu boden der Saunakabine 9 2 3 Heater Output 10 2 3 Leistung des Saunaofens 10 2 4 Ventilation of the Sauna Room 10 2 4 Ventilation in der 10 2 5 Hygienic Conditions of the Sauna Room 11 2 5 Hygiene in der Gaunakabine 11 3 INSTRUCTIONS FOR INSTALLATION 11 3 ANLEITUNG F R DEN INSTALLATEUR 11 3 1 Prior to 11 3 1 Vor der 11 3 2 Fastening the Heater on a Wall 12 3 2 Befestigung des Saunaofens an 3 3 Installation of the Heater Recess 12 der ne eR m 12 3 4 Safety 12 3 3 Installation des Saunaofens 3 5 Installation of the control unit einer Nische eren naar 12 C90 C150 and sensors 3 4 Schutzgel nder een 12 BC45E 6 BC80E BC9OE 12 3 5 Anschlu des Steuergerates C90 C150 3 6 Electrical Connections 13 und der F hler BCA5E 6 BC80E 3 6 1 Resetting the overheating limiter BEE Erna 12 BC45 60 BC80 90 14 3 6 Elektroanschl ffe nennen 13 3 7 Electric heater insu
23. er Krankheit leiden Schwangeren und Kleinkindern ist der Gebrauch untersagt Falls Sie an einer Krankheit leiden besonders falls diese Krankheit mit Hitze zusammenh ngt falls Sie an Fettleibigkeit einer Herzkrankheit niedrigem oder hohem Blutdruck Kreislaufproblemen oder Diabetes leiden suchen Sie unbedingt einen Arzt auf 5 Benutzen Sie die Sauna nicht falls Sie unter dem Einfluss von Alkohol Drogen oder Medikamenten stehen da dies zu einer Bewusstlosigkeit f hren kann ST a Kontaktdaten Bei Fragen zur Montage wenden Sie sich bitte an unsere Service Abteilung Service zanier at oder 0043 4852 68866 18 Bedienungsanleitung Die Steuerung der Sauna erfolgt direkt ber den Ofen Die Anleitung dazu finden Sie im Anschlu Seite 9 BC45 BC60 80 90 BC45E BC60E BC80E BC90E Q Instructions for installation and use of Electric Sauna Heater DEI Gebrauchs und Montageanleitung des Elektrosaunaofens 05102006H EN Purpose of the electric heater The BC BCE heater is designed for the heating of family saunas to bathing temperature It is forbidden to use the heater for any other purposes The guarantee period for heaters and control equipment used in saunas by families is two 2 years The guarantee period for heaters and control equipment used in saunas by building residents is one 1 year Please read the user s instructions carefully before using the heater NOTE These instructions for i
24. er the flammable material in the sauna room The maximum temperature allowed in the wall and ceiling surfaces of the sauna room is 140 degrees Celsius Sauna stoves equipped with CE signs meet all of the regulations for sauna installations Proper authorities monitor that the regulations are being followed 2 2 Sauna Room Floor Due to a large variation in temperature the sauna stones disintegrate in use Small pieces of stone are washed down on the sauna room floor along with the water thrown on the stones Hot pieces of stone may damage plastic floor coverings installed underneath and near the heater A light coloured joint grout used for a tiled floor may absorb impurities from the stones and water e g iron content To prevent aesthetic damage due to the reasons presented above only dark joint grouts and floor coverings made of rock materials should be used underneath and near the heater DE Um eine angemessene Saunaofenleistung zu erreichen kann es erforderlich werden die Saunadecke weiter nach unten abzusenken norm 2100 2300 mm min Saunah he 1900 mm so da der Rauminhalt der Sauna kleiner wird und eventuell eine geringere Saunaofenleistung gew hlt werden kann Die Absenkung der Decke wird durchgef hrt indem man das auf passender H he anbringt Die Balkenzwischenraume werden isoliert Isolation mindestens 100 mm und wird wie oben beschrieben von innen verkleidet Da W rme nach oben stei
25. g l Bei Verwendung kalkhaltigen Wassers verbleibt auf den Steinen und Metalloberflachen des Saunaofens eine helle cremeartige Schicht Die Verkalkung der Steine schw cht die Aufgu eigenschaften ab Bei Verwendung eisenhaltigen Wassers verbleibt auf der Ofenoberflache und den Widerstanden eine rostige Schicht die Korrosion verursacht Die Verwendung von humus und chlorhaltigem Wasser sowie von Meerwasser ist verboten Im Aufgu wasser d rfen nur f r diesen Zweck ausgewiesene Duftstoffe verwendet werden Befolgen Sie die Anweisungen auf der Packung 1 4 2 Temperatur und Feuchtigkeit in der Saunakabine Zur Messung der Temperatur und Feuchtigkeit gibt es Mef amp gerate die f r den Gebrauch in einer Sauna geeignet sind Es ist allerdings unm glich allgemeing ltig und genau die zum Saunen geeigneten Temperaturen oder Feuchtigkeitsprozente zu nennen da jeder Mensch die Wirkung des Aufgusses in der Sauna anders empfindet Das eigene Empfinden ist das beste Thermometer des Badenden Eine sachgem e Ventilation in der Sauna ist wichtig denn die Saunaluft mu sauerstoffreich und leicht zu atmen sein Siehe Kapitel 2 4 Ventilation in der Saunakabine Menschen empfinden das Saunen als gesund und erfrischend Das Saunen s ubert erw rmt entspannt beruhigt lindert psychische Bedr cktheit und bietet als ruhiger Ort die M glichkeit zum Nachdenken 1 5 Anleitungen zum Saunen e Waschen Sie sich vor dem Saunen Eine Dusche
26. gt wird als Abstand zwischen Saunabank und Decke h chstens 1100 1200 mm empfohlen ACHTUNG Zusammen mit einem Brandschutz beamten mu festgestellt werden welche Teile der Brandmauer isoliert werden d rfen Sich in Benutzung befindliche Abz ge d rfen nicht isoliert werden ACHTUNG Der Schutz von W nden oder der Decke mit leichten Abdeckungen z B Mineralplatten die direkt an den Wand oder Deckenfl chen befestigt werden kann einen gefahrlichen Temperaturanstieg in den Wand und Deckenmaterialien verursachen 2 1 1 Verf rbung der Saunaw nde Die Holzmaterialien in der Sauna wie z B die Holzverkleidungen verf rben sich mit der Zeit dunkel Dieser Prozess wird durch das Sonnenlicht und die Hitze des Saunaofens beschleunigt Wurden die Wandverkleidungen mit einem speziellen Schutzmittel behandelt kann die Verf rbung der Wand ber dem Ofen je nach verwendetem Schutzmittel relativ schnell beobachtet werden Diese Verf rbungen entstehen dadurch dass die Schutzmittel eine geringere Hitzebestandigkeit aufweisen als unbehandeltes Holz Dies hat sich in Praxistests herausgestellt Die Mikromineralstoffe die sich von den Steinen auf dem Ofen abl sen k nnen die Wandoberflache in der Nahe des Ofens dunkel verfarben Wenn Sie bei der Installation des Saunaofens die vom Hersteller empfohlenen Richtlinien einhalten erhitzt sich der Saunaofen nur so weit dass keine Gefahr f r die brennbaren Materialien der Saunakabine beste
27. h Bathing cleans and warms your body relaxes the muscles soothes and alleviates oppression As a quiet place the sauna offers the opportunity to meditate 1 5 Instructions for Bathing e Begin by washing yourself for example by taking a shower e Stay in the sauna for as long as you feel comfortable e According to established sauna conventions you must not disturb other bathers by speaking in a loud voice e Do not force other bathers from the sauna by throwing excessive amounts of water on the stones e Forget all your troubles and relax e Cool your skin down as necessary e f you are in good health you can have a swim if a swimming place or pool is available e Wash yourself properly after bathing Have drink of fresh water or a soft drink to bring your fluid balance back to normal e Rest for a while and let your pulse go back to normal before dressing 1 6 Warnings e Sea air and a humid climate may corrode the metal surfaces of the heater e Do not hang clothes to dry in the sauna as this may cause a risk of fire Excessive moisture content may also cause damage to the electrical DE e Humusgehalt Farbe Geschmack Ablagerungen Empfehlung unter 12 mg l e Eisengehalt Farbe Geruch Geschmack Ablagerungen Empfehlung unter 0 2 mg l e die wichtigsten Stoffe sind Mangan Mn und Kalzium Ca oder Kalk Empfehlung f r Mangan unter 0 05 mg l und f r Kalzium unter 100 m
28. ht Die zulassige H chsttemperatur f r die Wand und Deckenoberflachen der Saunakabine betragt 140 Grad Celsius Sauna fen die ber ein CE Symbol verf gen erf llen alle Bestimmungen f r Saunaanlagen Die entsprechenden Beh rden kontrollieren ob diese Bestimmungen eingehalten werden 2 2 Fuf boden der Saunakabine Aufgrund der gro en W rme nderungen werden die Saunasteine spr de und br chig Steinsplitter und feine Gesteinsmaterialien werden mit dem Aufgu wasser auf den Saunafu boden gesp lt Hei e Steinsplitter k nnen kunststoff beschichtete Fu bodenbel ge unter dem Saunaofen und in dessen unmittelbarer N he besch digen Unreinheiten der Saunasteine und des Aufgu wassers z B Eisengehalt k nnen von hellen Fugenmaterialien gekachelter Fu b den aufgesogen werden Um die Entstehung sthetischer M ngel aus oben genannten Gr nden zu verhindern sollten unter dem Saunaofen und in dessen unmittelbarer N he steinhaltige Fu bodenbeschichtungen und dunkle Fugenmaterialien verwendet werden 9 EN 2 3 Heater Output When the walls and ceiling are covered with panels and the insulation behind the panels is sufficient to prevent thermal flow into the wall materials the heater output is defined according to the cubic volume of the sauna See table 1 If the sauna has visible uninsulated wall surfaces such as walls covered with brick glass block concrete or tile each square metre of said wall surfa
29. ktroanschl sse das Steuerger t C90 und des Saunaofens BCE 17 4 SPARE PARTS ERSATZTEILE EN SES S 1 1500W 230V ZSB 224 2 2000W 230V ZSB 226 X 3 2670W 230V ZSB 228 4 3000W 230V ZSB 229 9 DEINER ZSK 510 BC 25 520 Harvia Oy 12 FI 40951 Muurame www harvia fi 18
30. lation resistance 16 3 6 1 R cksetzung des berhitzungsschutzes BC45 BC60 BC80 BC90 14 3 7 Isolationswiderstand des Hektrosaunaotens nn nn 00 16 E SPARE PARTS 18 4 ERSATZTEILE iiciin une WW 2 EN 1 INSTRUCTIONS FOR USE 1 1 Piling of the Sauna Stones The sauna stones for an electric heater should be 4 8 cm in diameter The heater stones should be solid blocks of stone specially intended for use in the heater Neither light porous ceramic stones of the same size nor soft potstones should be used in the heater because they may cause the resistance temperature to rise too high as a result of which the resistance may be broken Stone dust should be washed off before piling the stones The stones should be piled into the stone compartment over the grating between the heating elements resistances so that the stones support each other The weight of the stones should not lie on the heating elements The stones should not be piled too tightly so that air can flow through the heater The stones should be fitted loosely and not wedged between the heating elements Very small stones should not be put into the heater at all The stones should completely cover the heating elements However they should not form a high pile on the elements See fig 1 The stones disintegrate with use Therefore they should be rearranged at least once a year or even more often if
31. mu in einem trockenen Raum installiert werden z B im Umkleideraum Das Ther mostat widerum wird in der Saunakabine ber dem Saunaofen in der N he der Decke angebracht Weitere Anweisungen finden Sie in der Installationsanleitung des Steuerger ts 1 4 Aufguss Die Saunaluft trocknet bei Erw rmung aus daher sollte zur Erlangung einer angenehmen Luftfeuchtigkeit auf die hei en Steine des Saunaofens Wasser gegossen werden Mit der Wassermenge wird die f r angenehm emp fundene Aufgu feuchtigkeit reguliert Wenn die Luftfeuchtigkeit passend ist schwitzt die Haut des Badenden und das Atmen in der Sauna f llt leicht Es empfiehlt sich zun chst nur kleine Mengen Wasser auf die Steine zu gie en damit die Wirkung der Feuchtigkeit auf die Haut erprobt werden kann Zu hohe Temperaturen und Feuchtigkeitsprozente f hlen sich unangenehm an Ein langer Aufenthalt in einer hei en Sauna f hrt zum Ansteigen der K rpertemperatur was gef hrlich sein kann Die Kapazit t der Saunakelle sollte h chstens 2 di betragen Auf die Steine sollten keine gr eren Wassermengen auf einmal gegossen werden da beim Verdampfen sonst kochend hei es Wasser auf die Badenden spritzen k nnte Achten Sie auch darauf da Sie kein Wasser auf die Steine gie en wenn sich jemand in deren N he befindet Der hei e Dampf k nnte Brandwunden verursachen 1 4 1 Aufgu wasser Als Aufgu wasser sollte nur Wasser verwendet werden das die Qualit tsvo
32. n h rt man die Uhr aber die Widerstande erwarmen sich nicht BC e Der Uhrschalter ist auf den Bereich 0 4 gestellt in dem sich der Saunaofen erwarmt BC 2 SAUNAKABINE 2 1 Isolation der Saunakabine und Wandmaterialien In einer elektrisch beheizten Sauna m ssen alle massiven Wandfl chen die viel W rme speichern Ziegel Glasziegel M rtel o ausreichend isoliert werden um mit einer relativ geringen Leistung des Saunaofens auszukommen F r gut isoliert kann man eine solche Sauna halten die mit folgender Wand und Deckenstruktur ausgestattet ist e Die Dicke der sorgf ltig gelegten Isolierwolle betr gt auch im Hausinneren 100 mm mindestens 50 mm e Als Feuchtigkeitssperre wird z B Aluminiumpapier verwendet dessen R nder sorgf ltig dicht gefaltet werden und das so angebracht wird da die gl nzende Seite zum Inneren der Sauna zeigt e Zwischen Feuchtigkeitssperre und Paneelen befindet sich empfehlenswert ein 10 mm gro er Entl ftungsspalt e Als Innenbeschichtung werden leichtgewichtige Paneelbretter verwendet die eine Dicke von etwa 12 16 mm haben e Uber der Wandverkleidung an der Grenze zu den Deckenpaneelbrettern wird ein Entl ftungsspalt von einigen mm gelassen EN When aiming at reasonable heater output it may be advisable to lower the ceiling of the sauna normally 2100 2300 mm minimum height 1900 mm As a result the volume of the sauna is decreased and a smaller heater o
33. nd die W rmeisolation hinter den Paneels ausreichend ist um das Entweichen der W rme in die Wandmaterialien zu verhindern h ngt die erforderliche Leistung des Ofens von der Gr e des Innenraumes Ihrer Sauna ab siehe Tabelle 1 Falls in der Sauna unisolierte Wandfl chen wie Ziegel Glasziegel Glas Beton oder Kachelfl chen sichtbar sind sollte f r jeden Quadratmeter dieser Fl chen 1 2 m zum Rauminhalt addiert und aufgrund dieser Summe die entsprechende Ofenleistung aus der Tabelle bestimmt werden Saunas mit Blockbohlenw nden erw rmen sich langsam so da man bei der Bestimmung der Ofenleistung den Rauminhalt dieser Saunas mit 1 5 multiplizieren sollte 2 4 Ventilation in der Saunakabine Besonders wichtig f r das Saunen ist eine gute Ventilation Die Luft in der Saunakabine sollte in der Stunde sechsmal wechseln Das Frischluftrohr sollte direkt von drau en kommen und sollte nach neustem Stand der Forschungen ber dem Saunaofen in mindestens 50 cm H he angebracht werden Der Durchmesser des Rohres sollte ca 5 10 cm betragen Die Abluft sollte aus dem unteren Teil der Sauna direkt in einen Abzug oder durch ein knapp ber dem Saunaboden beginnendes Abzugsrohr zu einem Ventil im oberen Teil der Sauna geleitet werden Die Abluft kann auch unter der T r hindurch nach au en geleitet werden wenn sich unter der T r die zum Waschraum mit Abluftventil f hrt ein etwa 5 cm breiter Spalt befindet Die Abluft der Sa
34. ne d rfen nicht zu dicht gesetzt werden damit die Luftzirkulation nicht behindert wird Auch d rfen die Steine nicht eng zwischen den Heizelementen verkeilt werden die Steine sollten locker gesetzt werden Sehr kleine Steine sollen nicht in den Saunaofen gelegt werden Die Steine sollen die Heizelemente vollst ndig bedecken sie d rfen aber nicht hoch ber den Saunaofen herausragen Siehe Abb 1 W hrend des Gebrauchs werden die Steine spr de Aus diesem Grund sollten die Steine mindestens einmal j hrlich neu aufgeschichtet werden bei starkem Gebrauch fter Bei dieser Gelegenheit entfernen Sie bitte auch Staub und Gesteinssplitter aus dem unteren Teil des Saunaofens und erneuern besch digte Steine Die Garantie kommt nicht f r Sch den auf die durch Verwendung anderer als vom Werk empfohlener Saunaofensteine entstehen Die Garantie kommt auch nicht f r Sch den des Saunaofens auf die durch Verstopfung der Luftzirkulation durch bei Gebrauch spr de gewordene Steine oder zu kleine Steine entstehen In der Steinkammer oder in der N he des Saunaofens d rfen sich keine Gegenst nde oder Ger te befinden die die Menge oder die Richtung des durch den Saunaofen f hrenden Luftstroms ndern und somit eine berhitzung der Widerst nde sowie Brandgefahr der Wandfl chen verursachen Figure 1 Abbildung 1 Piling of the sauna stones Aufschichtung der Saunaofensteine EN 1 2 Heating of the Sauna When th
35. ng ist in Bezug auf den Montageort rechtsseitig e Sind genug Saunaofensteine von guter Qualit t vorhanden e Ist die Netzspannung f r den Saunaofen geeignet e Falls das Haus elektrisch beheizt wird ben tigt der Steuerkreis Kontaktor der Heizung ein Zwischenrelais um die Steuerfunktion auf Heater Ofen Output Sauna room Minimum distances Connecting cable Fuse Leistung Saunakabine Min Abstand des Ofen Anschlu kabel Sicherung Model and dimensions kW Cubic vol Height A B C to ceiling to floor 400V 3N Fuse Modell und Ma e Rauminhalt H he min min min zur Decke zum Boden Sicherung Width Breite BC 480 mm S BCE 450 mm See item 2 3 28 See fig 5 See fig 8 The measurements Depth Tiefe siehe Kap 2 3 fig 6 Siehe Abbildung 5 apply to the connection cable only 310 mm Siehe Height H he Abb 6 Siehe Abbildung 8 Die Messungen 540 mm beziehen sich ausschlie lich auf Weight Gewicht das Anschlusskabel 11 kg x min max min Stones Steine 3 max 25 kg m m mm mm mm mm mm mm mm A BC45 4 5 3 6 1900 35 20 35 1100 80 33 1 8 3x 10 BC60 6 0 5 8 1900 50 30 50 1100 80 5x 1 5 10 BC80 8 0 7 12 1900 100 30 80 1100 80 5 55 2459 90 9 0 8 14 1900 120 40 100 1100 80 5 x 2 5 3x 16 BC45E 4 5 3 6 1900 35 20 35 1100 80 552145 3x10 6 6 0 5 8 1900 50 30 50 1100 80 5x 1 5 3x10 BC80E 8 0 7 12 1900 100 30 80 1100 80 el SO BC9
36. ngebracht werden m ssen f r den Gebrauch bei 125 C Umgebungstemperatur zugelassen sein Vermerk T125 Elektroanschl sse des Saunaofens BC Im Saunaofen befindet sich eine eingebaute Steuerzentrale Die Steuerzentrale ist au er dem Netzanschlu mit einem zus tzlichen Anschluss P ausgestattet die Steuerung der Elektroheizung gestattet Siehe Abb 9 Das Steuerungskabel f r die Elektroheizung wird direkt zur Klemmdose des Saunaofens gelegt und von dort aus ein Gummikabel der gleichen St rke weiter zur Reihenklemme des Saunaofens 3 6 1 R cksetzung des berhitzungsschutzes BC45 BC60 80 90 Der R cksetzknopf befindet sich in der Elektrobuchse im Rahmenteil des Thermostats siehe Abb 12 daher m ssen die Saunaofensicherungen an der Elektrotafel zun chst gel st werden 1 Entfernen Sie die Drehhebel des Thermostats und die Zeitschaltuhr indem Sie sie herausziehen 2 L sen Sie die Schraube M4x5 unter dem Hebel der Zeitschaltuhr 3 L sen Sie die Sicherungsschrauben 2 der Schaltergeh useabdeckung am unteren Ende des Geh uses und entfernen Sie die Abdeckung des Schaltergeh uses Der Begrenzer wird durch Druck in seine Funktions stellung zur ckgesetzt bei Bedarf mit einer Kraft die 7 kg entspricht im Begrenzer ist dann ein Knacken zu h ren Siehe Abbildung 12 EN 45 80
37. nstallation and use are intended for the owner or the person in charge of the sauna as well as for the electrician in charge of the electrical installation of the heater After completing the installation the person in charge of the installation should give these instructions to the owner of the sauna or to the person in charge of its operation Congratulations on your choice DE Verwendungszweck des Saunaofens Der BC BCE Saunaofen ist zur Beheizung von Familiensaunen auf Aufgu amp temperatur bestimmt Die Verwendung zu anderen Zwecken ist verboten Die Garantiezeit f r in Familiensaunen verwendete Sauna fen und Steuerger te betr gt zwei 2 Jahre Die Garantiezeit f r Sauna fen und Steuerger te die in Gemeinschaftsaunen in Privatgeb uden verwendet werden betr gt ein 1 Jahr Lesen Sie vor Inbetriebnahme die Anleitung f r den Benutzer sorgf ltig durch ACHTUNG Diese Montage und Gebrauchsanleitung richtet sich an den Besitzer der Sauna oder an die f r die Pflege der Sauna verantwortliche Person sowie an den f r die Montage des Saunaofens zust ndigen Elektromonteur Wenn der Saunaofen montiert ist wird diese Montage und Gebrauchsanleitung an den Besitzer der Sauna oder die f r die Pflege der Sauna verantwortliche Person bergeben Wir begl ckw nschen Sie zu Ihrer guten Saunaofenwahl CONTENTS INHALT N 1 12 FOR USE u anne 3 1 ANLEITUNG F R DEN 3 1 1
38. rschriften f r Haushalts wasser erf llt Wichtige Faktoren f r die Wasser qualit t sind EN e humuos content colour taste precipitates recommended content less than 12 mg litre e iron content colour smell taste precipitates recommended content less than 0 2 mg litre e hardness the most important substances manganese Mn and calcium Ca recommended content of manganese 0 05 mg litre calcium less than 100 mg litre Calcareous water leaves a white sticky layer on the stones and metal surfaces of the heater Calcification of the stones deteriorates the heating properties Ferrous water leaves a rusty layer on the surface of the heater and elements and causes corrosion The use of humous chlorinated water and seawater is forbidden Only special perfumes designed for sauna water may be used Follow the instructions given on the package 1 4 2 Temperature and Humidity of the Sauna Room Both thermometers and hygrometers suitable for use in a sauna are available As the effect of steam on people varies it is impossible to give an exact universally applicable bathing temperature or percentage of moisture The bather s own comfort is the best guide The sauna room should be equipped with proper ventilation to guarantee that the air is rich in oxygen and easy to breathe See item 2 4 Ventilation of the Sauna Room Bathing in a sauna is considered a refreshing experience and good for the healt
39. s Never throw water on the stones when there are people near the heater because hot steam may burn their skin 1 4 1 Sauna Water The water to be thrown on the heated stones should meet the requirements of clean household water The factors essentially affecting the quality of water include the following 6 DE Vor Bet tigung des Knopfes mu die Ursache der Fehlfunktion festgestellt werden e Sind die Steine im Saunaofen verkeilt oder spr de e War der Saunaofen lange angeschaltet und wurde nicht benutzt e Ist die Halterung des Thermostatf hlers verbogen und liegt an der Seitenwand des Saunaofens an e War der Saunaofen starken St en ausgesetzt 1 3 2 fen mit separatem Steuerger t BC45E BC60E BC80E BC9OE Die fen BC45 6 BC80E und werden mit einem separaten Steuergerat C90 C150 bedient Die fen und der F hlerkasten der mit dem Steuergerat C90 C150 geliefert wird werden laut dieser Gebrauchs und Montageanleitung montiert Mit dem Steuergerat C90 C150 wird eine separate Gebrauchs und Montageanleitung geliefert Die Funktionen des Steuergerats werden von den Komponenten des F hlergeh uses gesteuert geregelt In dem F hlergeh use befinden sich ein Temperaturf hler und ein Uberhitzungsschutz Ein NTC Thermistor tastet die Temperatur ab und der r ckstellbare berhitzungsschutz unterbricht beim Auftreten eines Defekts die Stromzufuhr zum Saunaofen Das Steuerger t
40. s to the sauna age temperature of the sauna time spent in the warm sauna e very careful when moving the sauna as the platform and floors may be slippery e Never go to a hot sauna if you have taken alcohol strong medicines or narcotics 1 7 Troubleshooting If the heater does not heat check the following points e the electricity has been switched on e thermostat shows a higher figure than the temperature of the sauna e the fuses to the heater in good condition e the temperature guard has not gone off The timer sound is heard but the elements are not heated BC e the timer has been switched to a section where the heater should be heated 0 4 BC 2 THE SAUNA ROOM 2 1 Insulation and Wall Materials of the Sauna Room In an electrically heated sauna all the massive wall surfaces which store plenty of heat such as bricks glass blocks plaster etc must be sufficiently insulated in order to keep the heater output at a reasonably low level A wall and ceiling construction can be considered to have efficient thermal insulation if e thickness of carefully fitted insulating wool inside the house is 100 mm minimum 5O mm e the moisture protection consists of e g aluminium paper with tightly taped edges The paper must be fitted so that the glossy side is towards the inside of the sauna e there is 10 mm vent gap between the moisture protection and panel boards recommenda
41. schalters hat zwei Bereiche von denen der erste gr ere Nummern der Sofort Einschalten Bereich ist der Saunaofen wird f r die einprogrammierte Zeit 0 4 set section 1 8 hours which is used to start the heater after a certain time The heater starts when the timer has turned the switch back to the instantly on section that is at number four 4 After this the heater will be on for about 4 hours unless the switch is turned to zero before that At zero O the supply to the elements is cut off and the heater is switched off See fig 2 Stunden eingeschaltet Der zweite Bereich der Skala ist der sogenannte Vorwahl Bereich 1 8 Stunden In diesem Bereich erwarmt sich der Saunaofen nach einer gew nschten Wartezeit Die Erwarmung beginnt wenn der Uhrmechanismus den Schalter bis auf den Sofort Einschalten Bereich zur ckgedreht hat d h bis auf die Nummer Vier 4 Danach ist der Saunaofen f r etwa 4 Stunden eingeschaltet falls der Schalter nicht schon fr her auf die O Stellung zur ckgedreht wird in der sich Figure 2 Abbildung 2 Timer die Widerstandsstr me abschalten und sich Uhrschalter der Saunaofen abk hlt Siehe Abb 2 EN Example 1 You want to go jogging and have sauna bath after that The estimated duration of your run is 5 hours Turn the timer clockwise over the scale O 4 to the pre set section scale 1 8 at number 4 The timer will start and after four hours
42. t Lienz H Gmeiner Str 7 Tel 43 0 4852 68866 info zanier at www fitstore24 at WICHTIG Die Montage und Betriebsanleitung enthalt wichtige Informationen Uber die anzuwendenden SICHERHEITSMASSNAHMEN fur die Installation und Inbetriebnahme Es ist daher unerl sslich dass die Anweisungen vom Benutzer vor der Montage und Inbetriebnahme aufmerksam durchgelesen werden Nutzungsbedingungen Umgebungstemperatur 15 bis 40 C Luftfeuchtigkeit lt 85 Luftdruck 700 bis 1600 hpa Stromanschluss Starkstrom entsprechend hitzebest ndiges Stromanschlusskabel muss von einem zertifizierten Elektriker gestellt und montiert werden Verpackung Die Finnische Sauna wird in 4 Kartons geliefert Lagern und transportieren Sie das Ger t unbedingt in der am Karton bezeichneten Lage Verkehrt aufgestellte Kartons k nnen Sch den an der Kabine verursachen Alle von uns vertriebenen Produkte und Verpackungen sind ARA und ERA lizensiert Installationsinformation a Die Sauna sollte auf einem ebenen Untergrund aufgestellt werden b Die Sauna muss in einem trockenen und berdachten Raum aufgestellt werden c Lagern Sie kein entflammbares Material oder chemische Substanzen in die N he der Infrarotkabine Montageanleitung Die Montage der Sauna erfordert die Zusammenarbeit von mindestens zwei erwachsenen Personen Bitte lesen Sie die Bedienungs und Montageanleitung vollst ndig und sorgf ltig bis zum Ende durch bevor Sie mit der Montag
43. t contactor require a supplementary relay to make the pilot function potentialfree because voltage DE Falls der Saunaofen in eine Fertigsauna eingebaut wird m ssen die Ventilationsanweisungen des Saunaherstellers befolgt werden In der Abbildungsserie sind Beispiele f r Ventilations strukturen dargestellt Siehe Abb 4 2 5 Hygiene in der Saunakabine Damit das Saunen angenehm ist mu f r die Hygiene in der Saunakabine gesorgt werden Wir empfehlen in der Sauna auf Saunat chern zu sitzen damit der Schwei nicht auf die B nke l uft Nach Gebrauch sollten die Saunat cher gewaschen werden F r G ste sollten Sie eigene Saunat cher bereithalten In Verbindung mit der Reinigung der Sauna sollte der Fu boden der Saunakabine gesaugt gefegt und mit einem feuchten Lappen gewischt werden Mindestens jedes halbe Jahr sollte die Sauna gr ndlich geputzt werden Die W nde B nke und der Fu boden der Saunakabine sollten mit einer B rste und mit Saunareinigungsmittel abgewaschen werden Vom Saunaofen werden Staub und Schmutz mit einem feuchten Tuch abgewischt 3 ANLEITUNG FUR DEN INSTALLATEUR 3 1 Vor der Montage Bevor Sie den Saunaofen installieren lesen Sie die Montageanleitung und berpr fen Sie folgende Dinge e Ist der zu montierende Saunaofen in Leistung und Typ passend f r die Saunakabine Die Rauminhaltswerte in Tabelle 1 d rfen weder ber noch unterschritten werden e Die Anschlu richtu
44. the heater will come on Because it takes about one hour for the sauna to be heated it will be warm and ready for bathing after about 5 hours that is when you come back from your run Example 2 If you want to bathe immediately and thus do not want to use the pre set timing the timer must be set to the desired point in the section 0 4 Then the heater will be switched immediately on and the sauna will be ready for bathing after about one hour Switch the heater off immediately after bathing and check that the sauna stones are dry Sometimes it may be advisable to leave the heater on for a while to let the wooden parts of the sauna dry properly NOTE It is absolutely necessary to check that the timer has cut off the supply of the elements after the set time DE Beispiel 1 Eine Person m chte eine Wanderung unternehmen und danach in die Sauna gehen Die Wanderung dauert etwa 5 Stunden Der Uhrschalter der Sauna mu also Uhrzeigersinn ber den Funktionsbereich Skala 0 4 hinaus auf den Vorwahl Bereich Skala 1 8 auf Nummer 4 gedreht werden Die Uhr l uft und nach vier Stunden schaltet sich der Saunaofen an und erwarmt sich Da die Erw rmungszeit der Sauna etwa eine Stunde betr gt ist die Sauna in etwa 5 Stunden warm also genau dann wenn die Person von der Wanderung wieder zur ck ist Beispiel 2 Wenn eine Person sofort in die Sauna gehen m chte also nicht die Vorwahlfunktion verwenden m chte mu
45. the sauna is in frequent use At the same time any pieces of stones should be removed from the bottom of the heater and disintegrated stones should be replaced with new ones The guarantee does not cover any faults caused by the use of stones not recommended by the plant Neither does the guarantee cover any faults caused by disintegrated or too small stones blocking the heater ventilation No such objects or devices should be placed inside the heater stone space or near the heater that could change the amount or direction of the air flowing through the heater thus causing the resistance temperature to rise too high which may set the wall surfaces on fire DE 1 ANLEITUNG FUR DEN BENUTZER 1 1 Aufschichten der Saunaofensteine Die passenden Steine fiir einen Elektrosaunaofen haben einen Durchmesser von 4 8 cm Als Saunaofensteine sollten speziell f r Saunadfen gedachte bekannte massive Bruchsteine verwendet werden Die Verwendung leichter por ser und gleichgro er keramischer Steine ist verboten da durch sie die Widerst nde berhitzt und besch digt werden k nnen Als Saunaofensteine d rfen auch keine weichen Topfsteine verwendet werden Die Steine sollten vor dem Aufschichten von Steinstaub befreit werden Die Steine werden auf den Rost in den Saunaofen in die Zwischenr ume der Heizelemente so gesetzt da die Steine einander tragen Das Gewicht der Steine darf nicht von den Heizelementen getragen werden Die Stei
46. tion e the inside is covered by 12 16 mm thick panelling e there is a vent gap of a few millimetres at the top of the wall covering at the edge of the ceiling panelling DE hohe Feuchtigkeit besch digt werden e Achtung vor dem hei en Saunaofen Die Steine so wie das Geh use werden sehr hei und k nnen die Haut verbrennen e Auf die Steine darf nicht zuviel Wasser auf einmal gegossen werden da das auf den hei en Steinen verdampfende Wasser die Haut verbrennen kann e Kinder Gehbehinderte Kranke und Schwache d rfen in der Sauna nicht alleingelassen werden e Gesundheitliche Einschr nkungen bezogen auf das Saunen m ssen mit dem Arzt besprochen werden e Eltern d rfen ihre Kinder nicht die N he des Saunaofens lassen e ber das Saunen von Kleinkindern sollten Sie sich in der M tterberatungsstelle beraten lassen Alter Saunatemperatur Saunadauer e Bewegen Sie sich in der Sauna mit besonderer Vorsicht da die B nke und der Fu boden glatt sein k nnen e Gehen Sie nicht in die Sauna wenn Sie unter dem Einflu von Narkotika Alkohol Medikamenten Drogen usw stehen 1 7 St rungen Falls sich der Saunaofen nicht erw rmt berpr fen Sie folgende Punkte e Strom ist eingeschaltet e Das Thermostat ist auf eine h here als der Sauna herrschende Temperatur eingestellt e Die Sicherungen des Saunaofens sind heil e Der Temperaturschutz ist nicht entriegelt worden In dieser Situatio
47. una floor must be approved for use in a temperature of 125 C marking T125 Electrical connections of heater BC The heater has a built in control unit In addition to supply connectors the control unit is equipped with an additional connector P which makes control of electrical heating possible See fig 9 The control cable for electrical heating is brought directly into the junction box of the heater and from there to the terminal block of the heater along a rubber cable with the same thickness as that of the connection wire 3 6 1 Resetting the overheating limiter BC45 BC60 BC80 90 The reset button is located on the thermostat frame on the electrical box see fig 12 and consequently the fuses of the heater on the electrical panel must be removed before commencing the work 1 Detach the turnable levers of the thermostat and the timer by pulling them outwards 2 Detach the M4x5 screw below the timer lever 3 Detach the fastening screws 2 of the connection box cover on the lower end of the box and remove the cover of the connection box Reset the limit stop by pressing with 7 kg force if necessary so that a clicking sound is heard See figure 12 Falls der Anschlu oder die Montagekabel in die Sauna oder die Saunaw nde in einer H he Uber 100 cm Uber dem Boden m nden m ssen sie belastet mindestens eine Temperatur von 170 C aushalten z B SSJ Elektroger te die h her als 100 cm vom Saunaboden a
48. unakabine sollte m glichst weit entfernt vom Saunaofen aber so nahe wie m glich am Fu boden abgef hrt werden Die Querschnittsfl che des Abzugsrohres sollte zweimal gr er als die des Frischluftrohres sein Die oben erw hnte Ventilation funktioniert wenn sie maschinell verwirklicht wird i i 4 3 1 Air supply vent 2 Optional air supply vent if mechanical exhaust ventilation is used The opening is located 50 cm above the heater 3 Exhaust air vent 4 Possible drying valve which is closed during heating and bathing The sauna can also be dried by leaving the door open after bathing 5 If there is an exhaust vent in the washing room only there should be a minimum 5 cm opening under the sauna room door Mechanical ventilation is recommended Luftzufuhr ffnung Alternative Luftzufuhr ffnung wenn die Abluftventilation maschinell erfolgt Die ffnung befindet N sich 50 cm ber dem Saunaofen 3 Abluft ffnung 4 M gliches Trocknungsventil das w hrend der Erwarmung und des Saunens geschlossen ist Die Sauna kann auch getrocknet werden indem die T r nach dem Saunen offengelassen wird 5 Falls nur im Waschraum eine Abluft ffnung vorhanden ist sollte der Schwellenspalt der Saunat r mindestens 5 cm breit sein Eine maschinelle Luftabfuhr ist dann unerl lich
49. urch Drehen entgegen den Uhrzeigersinn etwas kleiner eingestellt werden Beachten Sie da schon eine kleine Abweichung von der maximalen Einstellposition eine sp rbare Temperaturver nderung in der Saunakabine hervorruft Siehe Abb 3 Falls die Temperatur in der Saunakabine aus irgendeinem Grund zu hoch ansteigt funktioniert die berhitzungsschutzeinheit des Thermostats als Schutzvorrichtung und schaltet die Widerstands str me des Saunaofens ab Erst nach Abk hlung des Saunaofens kann der berhitzungsschutz in die Stellung zur ckgebracht werden die den Stromflu durch das Thermostat erm glicht Zur Zur cksetzung des berhitzungsschutzes ist am Thermostat ein R cksetzknopf angebracht dieser befindet sich im Schaltkasten des Saunaofens Daher darf nur eine zu Elektroinstallationen befugte Person diese Arbeit ausf hren Siehe Kapitel 3 6 1 und Abb 12 5 EN against the side of the stone compartment e has the heater been banged or shaken 1 3 2 Heaters with separate control units BC45E BC60E BC80E BC9OE The BC45E 6 BC80E and BC9OE heaters are controlled from a separate control unit C90 C150 Install the heater and the sensor box delivered with the C90 C150 control unit according to these instructions for installation and use The control unit has it s own instructions The components of the sensor box monitor the functioning of the control unit The temperature sensor and the overheating limiter
50. ust not exceed 50 cm If the connection and installation cables are higher Der Temperaturf hler wird an der Saunawand oberhalb des Saunaofens 100 mm unterhalb der Decke auf der Achse in Breitenrichtung des Saunaofens angefracht 3 6 Elektroanschl e Der Anschlu des Saunaofens ans Stromnetz darf nur von einem zugelassenen Elektromonteur unter Beachtung der g ltigen Vorschriften ausgef hrt werden Die Kabel vom Saunaofen zur W rmesteuerung und zum Signallicht m ssen in ihrer Querschnittsfl che dem Netzkabel des Saunaofens entsprechen Der Saunaofen wird halbfest an die Klemmdose an der Saunawand befestigt Siehe Abb 8 Als Anschlu kabel wird ein Gummikabel vom Typ HO7RN F oder ein entsprechendes Kabel verwendet ACHTUNG PVC isolierte Kabel d rfen wegen ihrer schlechten Hitzebest ndigkeit nicht als Anschlu kabel des Saunaofens verwendet werden Die Klemmdose mu spritzwasserfest sein und darf h chstens 50 cm ber dem Fu boden angebracht werden 13 EN 1 Control Unit 2 Junction box 3 Connection cable max 500 mm 1 Schaltmechanismus 2 Klemmdose 3 Anschlu kabel Figure 8 Connections of the heater Abbildung 8 Anschlu des Saunaofens than 100 cm from the floor in the sauna or inside the sauna room walls they must be able to endure a minimum temperature of 170 C when loaded for example SSJ Electrical equipment installed higher than 100 cm from the sa
51. utput may be sufficient The ceiling can be lowered so that the ceiling joists are fixed at a suitable height The spaces between the joists are insulated minimum insulation 100 mm and surfaced as described above Because heat goes upwards a maximum distance of 1100 1200 mm is recommended between the bench and ceiling NOTE Consult fire extinguishing authorities to find out which part of the fireproof wall may be insulated Do not insulate air chimneys NOTE The protection of the walls or ceiling with heat protection such as mineral board fitted directly on the wall or ceiling may cause the temperature of the wall and ceiling materials to rise dangerously high 2 1 1 Blackening of the sauna walls Wooden material in a sauna such as panels blackens with age The blackening process is sped up by sunlight and the heat from the stove If the wall surfaces have been processed with protective panel agents the blackening of the surface of the wall above the stove can be seen quite quickly depending on the protective agent used The blackening is due to the fact that the protective agents have less resistance to heat than unprocessed wood do This has been proven in practical tests The micronic mineral aggregate that crumbles from the stones on the stove may blacken the wall surface near the stove When following the manufacturer s approved guidelines in the installation of the sauna stove the stove will not heat up enough to endang