Home

UCON-IP-NEO - Guntermann und Drunck

image

Contents

1. Anschluss Kaltger testecker IEC 320 C14 Spannung AC 100 240 V 60 50 Hz Stromaufnahme 0 3 0 2 A Redundante Typ externes Netzteil Stromversorgung Anschluss miniDIN 4 Power Buchse Spannung 12 VDC Stromaufnahme 1 2A Geh use Material Aluminium eloxiert Ma e B x H xT 435 x 44 x 356 mm Desktop 19 x 1 HE x 356 mm Rackmount Gewicht ca 3 0 kg Einsatzumgebung Temperatur 5 bis 40 C Luftfeuchte lt 80 nicht kondensierend Schnittstellen fiir Arbeitsplatz 1 x D Sub HD 15 Buchse Video 2 x PS 2 Buchse Tastatur Maus zum Matrixswitch 1 x RJ45 Buchse zum lokalen Netzwerk 1 x RJ45 Buchse Konformitat CE RoHs 11 G amp D UCON IP NEO About this manual This manual has been carefully compiled and examined to the state of the art G amp D neither explicitly nor implicitly takes guarantee or responsibility for the qual ity efficiency and marketability of the product when used for a certain purpose that differs from the scope of service covered by this manual For damages which directly or indirectly result from the use of this manual as well as for incidental damages or consequential damages G amp D is liable only in cases of intent or gross negligence Caveat Emptor G amp D will not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported
2. Back panel COM1 o uo o og u o MM e Network Keyb Mouse Monitor Transmission Red Power Figure 4 Left section of the back panel of the user module Both the Network and the Transmission port provide additional status LEDs which indicate the following operating conditions Section LED Status Meaning Network yellow blinking Indicates activity green on Established link blinking Link could not be established Transmission yellow on Port is used by another user off Free port green on Established connection to matrix system off No connection to matrix switch G amp D UCON IP NEO 10 Technical data Technical data UCON IP NEO Video Signal type analog video Resolution max 1920 x 1440 75Hz local connection Resolution max 1920 x 1200 60Hz IP connection native Transmission Distance between user module max 300 meters and target module Communication Ethernet 10 100 or 1000 Mbit s Delay compensation yes Consoles Total number 2 gt competing Number of local consoles al Number of IP consoles 1 Main power supply Type internal power pack Connection IEC plug IEC 320 C14 Voltage AC 100 240 V 60 50 Hz Power consumption 0 3 0 2 A Redundant Type external power pack power supply Connection miniDIN 4 power socket Voltage 12 VDC Power consumption 1 2A C
3. Installation Required accessories one CATS or better twisted pair cable to connect the user module to the IP network one CATS or better twisted pair cable to connect the user module to the matrix switch Connecting cables and devices coM1 0 o MM gt Bi Network Keyb Mouse Monitor Transmission Red Power Figure 1 Left section of the back panel of the user module Connection to the IP network IMPORTANT When configuring the network settings ofthe user module for the first time connect any computer to the Network port ofthe user module More information regarding this topic is given in the chapter Configuration before the start up on page 5 Network Insert a CATS or better twisted pair cable and establish a connection to the IP network Connection to a matrix switch Transmission Insert a CATS or better twisted pair cable Connect the other end of the cable to a Console port of the matrix switch belonging to the CAT Center series Optional Connecting the local console devices Keyb Connect the PS 2 keyboard of the local console Mouse Connect the PS 2 mouse of the local console Monitor Connect the monitor of the local console NOTE The service team uses the COM1 port for maintaining the devices 3 G amp D UCON IP NEO Installation Power supply il Red Power Main Power Fi
4. durch das Service Team verwendet 3 G amp D UCON IP NEO Installation Stromversorgung il Red Power Main Power Abbildung 2 Rechter Ausschnitt der R ckansicht des Arbeitsplatzmoduls Main Power Stecken Sie das mitgelieferte Stromversorgungskabel ein Red Power Optional kann ein Netzteil der Power Set 12 Serie angeschlossen werden Hierdurch wird eine zweite redundante Stromversorgung erreicht G amp D UCON IP NEO 4 Konfiguration vor Erstinbetriebnahme Konfiguration vor Erstinbetriebnahme Damit das Arbeitsplatzmodul f r alle Rechner innerhalb des lokalen Netzwerkes erreichbar ist sind die Netzwerkeinstellungen des Arbeitsplatzmoduls sowie der f r die Kommunikation mit der Software G amp D IP Console Client verwendete Port der TCP Verbindung ggf vor der Erstinbetriebnahme anzupassen Einstellungen der Netzwerkschnittstelle Die Einstellungen der Netzwerkschnittstelle k nnen an die Eigenschaften des Netz werks vor Ort angepasst werden Die folgende Tabelle listet die Einstellungen der Netzwerkschnittstelle im Auslieferungszustand auf IP Vergabe statisch IP Adresse 192 168 0 1 Subnet Mask 255 255 255 0 Verbindungstyp Auto So ndern Sie die Netzwerkeinstellungen vor der Erstinbetriebnahme 1 Schlie en Sie einen beliebigen Rechner an die Network Schnittstelle des Arbeits platzmoduls an Verwenden Sie hierzu ein Twisted Pair K
5. Login Click on Configuration Now the web application shows the current configuration settings Enter your date on the Server tab and click on Transfer to device IMPORTANT If no user accesses the user module within 5 minutes after the new network settings have been transmitted the defaults are reset see above Unplug the twisted pair cable from the computer G amp D UCON IP NEO Configuration before the start up Configuring the firewall of the IP network Accessing the web interface of the user module as well as starting a client requires a TCP connection for the following ports Port 443 https This port processes the communication of the computers within the IP net work with the web interface and the transmission of the Java client to the computers within the network Port 27998 The G amp D IP Console Client software uses this port to communicate with the user module The port settings can be changed within the web interface see below IMPORTANT Please ensure that the user module and the computers which use the web interface the Java client or the G amp D IP Console Client software have the rights to establish a connection to port 443 and or port 27998 If another application already uses port 27998 the port can be changed by the administrator How to change the TCP connection to communicate with the G amp D IP Console Client software 1 Start the internet
6. ak kassi na 5 Configuring the firewall of the IP network ooooccccnnnooooocnnnonccnnnnnnnonononcconanannnno 6 Starting the Java client 0000 eei A eSEE AAEE S ie 7 Resetting the defaults ooooooooooooccnnooooooccnccocconononononononnnnnnnon nono T E Se 8 Status displays soosiana ed essen ta 9 Front panel iu nenn Bra Run ash 9 Back panel usa eterno cat ier ace tees sire edema asl Eee uae 10 Techinicalidata aa tt eee eee 11 G amp D UCON IP NEO ii Safety instructions Safety instructions Please read the following safety instructions carefully before you start operating the G amp D product The instructions well help in avoiding damages to the product and in preventing possible injuries Keep this manual handy for all persons who will be using this product Follow all warnings or operating instructions which are on the device or stated in this user manual A Beware of electric shocks To avoid the risk of electric shock do not open the device or remove the covers If service is required please contact our technicians Disconnect the main power plug or the power supply before installation Before installation ensure that the device has been disconnected from the power source Disconnect the main power plug or the power supply of the device Ensure constant access to the power plugs During the installation of the devices ensure that the power plugs remain accessible Do not co
7. browser on a computer within the IP network and enter the fol lowing URL in the address bar https lt IP address UCON IP NEO gt e g https 192 168 0 1 2 Enter the access data of the administrator account in the Administration field of the web interface and click on Login 3 Click on Configuration The current configuration settings are shown in the web interface 4 Use the System tab to enter your desired port number in the TCP Port field Click on Transfer to device G amp D UCON IP NEO 6 Starting the Java client Starting the Java client The computers of the IP network can start and operate the IP console via the Java client of the user module or the G amp D IP Console Client software NOTE The separate manuals for the Java client and the supplied G amp D IP Console Client software give further information regarding this topic How to start the Java client 1 Start the internet browser on a computer within the IP network and enter the fol lowing URL in the address bar https lt IP address UCON IP eco gt e g https 192 168 0 1 2 Click on Start client 3 The Java client starts on the local computer and shows the login box 4 Enter your User name and Password and click on Login 7 G amp D UCON IP NEO Resetting the defaults Resetting the defaults The device provides a Reset button at the right hand side of the Status LED Use the button on the front side of the user mo
8. on the receipt of goods Have been damaged by non G amp D accessories G amp D will not be liable for any consequential damages that could occur from using the products Proof of trademark All product and company names mentioned in this manual and other documents you have received alongside your G amp D product are trademarks or registered trade marks of the holder of rights O Guntermann amp Drunck GmbH 2015 All rights reserved Version 1 01 19 02 2015 Firmware 1 0 000 00026 Guntermann amp Drunck GmbH Dortmunder Str 4a 57234 Wilnsdorf Germany Phone 49 0 2739 8901 100 Fax 49 0 2739 8901 120 http www GDsys de sales GDsys de i G amp D UCON IP NEO Contents Contents Safety instructions sineira ri AAE EE e a A nono EEA EE OEE 1 The user module UCON IP NEO e 2 Package contents ut aiii 2 Installation cita adi in leos 3 II A E RT 3 Connecting cables and devices oooooococccccnnoconoconononncnnnnannnnnnnncnnononono nono nnnnncinnannnnns 3 Connection to the IP Met work mssins nar oigan ekk RA kn 3 Connection to a matrix SWItCh oooooooococcccnononononcnnnnncnnnnnononnnnnncnnnnnnnnonnnnnnnnnnnns 3 Optional Connecting the local console devices oooooooooccocccccconooaoncnononcnnnonnnos 3 Power supply en an a La nennen S 4 Configuration before the start up oooooonococconncccnonooononcnonononcnnnono non nnnoncnonnnannnos 5 Network port settings sinnar tn
9. Guntermann amp Drunck GmbH Gea www gdsys de B UCON IP NEO Eg Installationsanleitung ES Installation Guide A DO BEE Zu dieser Dokumentation Diese Dokumentation wurde mit gr ter Sorgfalt erstellt und nach dem Stand der Technik auf Korrektheit berpr ft F r die Qualit t Leistungsf higkeit sowie Marktg ngigkeit des G amp D Produkts zu einem bestimmten Zweck der von dem durch die Produktbeschreibung abgedeckten Leistungsumfang abweicht bernimmt G amp D weder ausdr cklich noch stillschweigend die Gew hr oder Verantwortung F r Sch den die sich direkt oder indirekt aus dem Gebrauch der Dokumentation ergeben sowie f r beil ufige Sch den oder Folgesch den ist G amp D nur im Falle des Vorsatzes oder der groben Fahrl ssigkeit verantwortlich Gew hrleistungsausschluss G amp D bernimmt keine Gew hrleistung f r Ger te die nicht bestimmungsgem eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere u ere Besch digungen aufweisen welche nicht bei Lieferungserhalt angezeigt wurden durch Fremdzubeh r besch digt wurden G amp D haftet nicht f r Folgesch den jeglicher Art die m glicherweise durch den Einsatz der Produkte entstehen k nnen Warenzeichennachweis Alle Produkt und Markennamen die in diesem Handbuch oder in den brigen Dokumentationen zu Ihrem G amp D Produkt genannt werden sind Warenzeichen oder eingetragene Warenzeichen der entspreche
10. abel der Kategorie 5 2 Stellen Sie sicher dass die IP Adressen des Rechners sowie des Arbeitsplatzmo duls dem gleichen Subnetz zugeordnet sind Verwenden Sie beispielsweise die IP Adresse 192 168 0 10 3 Schalten Sie das Arbeitsplatzmodul ein 4 Starten Sie den Internet Browser des Rechners und geben Sie in der Adresszeile die URL 192 168 0 1 ein 5 Geben Sie im Bereich Administration der aufgerufenen Webapplikation die Zugangsdaten des Administratorkontos des Matrixswitches ein und klicken Sie auf die Schaltfl che Anmelden 6 Klicken Sie auf die Schaltfl che Konfiguration Die aktuellen Konfigurationsein stellungen werden in der Webapplikation angezeigt 7 Geben Sie auf der Registerkarte Server die von Ihnen gew schten Daten ein und klicken Sie abschlie end auf die Schaltfl che Zum Ger t bertragen WICHTIG Erfolgt innerhalb von 5 Minuten nach bertragung der neuen Netz werkeinstellungen keine Aufschaltung eines Benutzers auf das Arbeitsplatzmo dul werden die Standardeinstellungen s oben wiederhergestellt 8 Trennen Sie den Rechner vom Twisted Pair Kabel 5 G amp D UCON IP NEO Konfiguration vor Erstinbetriebnahme Konfiguration der Firewall des IP Netzwerkes Der Zugriff auf das Web Interface des Arbeitsplatzmoduls sowie die Ausf hrung eines Clients erfordert eine TCP Verbindung ber die nachfolgend aufgelisteten Ports Port 443 https ber diesen Port wird die Kommunikation de
11. asing Material anodised aluminium Dimensions W x H x D 435 x 44 x 356 mm desktop 19 x 1 U x 356 mm rack mount Weight approx 3 0 kg Operational environ Temperature 5 to 40 C ment Air humidity lt 80 non condensing Ports for console 1x D Sub HD 15 socket video 2 x PS 2 socket keyboard mouse to matrix switch 1x RJ45 socket to local network 1x RJ45 socket Conformity CE RoHs 11 G amp D UCON IP NEO E Das Handbuch wird fortlaufend aktualisiert und im Internet ver ffentlicht The manual is constantly updated and available on our website m http gdsys de A9100181 Guntermann amp Drunck GmbH Dortmunder Str 4a seit 1985 57234 Wilnsdorf Germany http www GDsys de Guntermann amp Pruner sales GDsys de BE EEE i B
12. dule if you want to reset the defaults NOTE To prevent you from pressing the button by accident you can only press the button with a thin pointy item How to reset the defaults 1 Turn the user module off 2 Press and hold the Reset button on the front side of the device 3 Keep the button pressed and turn on the device 4 Release the button when the Status LED starts blinking fast NOTE The defaults can also be reset in the web interface G amp D UCON IP NEO 8 Status displays Status displays Front panel Power System Red O Active Main Status e Figure 3 Right section of the front panel of the user module The LEDs on the front panel of the user module help you control the operating sta tus of the user module at all times Section LED Status Meaning Power Red on The optional power pack is connected and supplies the required voltage off The optional power pack is not connected or the connection to the mains could not be established Main on The power pack is turned on and supplies the required volt age off The power pack is turned off or the connection to the mains could not be established System Active blinking Active IP access via Java client or IP Console client off No IP access Status blinking The user module is ready for operation on The user module is booting 9 G amp D UCON IP NEO Status displays
13. en Sie einen d nnen und spitzen Gegenstand zur Bet tigung des Tasters So stellen Sie die Standardeinstellungen wieder her 1 Schalten Sie das Arbeitsplatzmodul aus falls dieses derzeit in Betrieb ist 2 Bet tigen Sie den Reset Taster an der Frontseite des Ger tes und halten Sie den Taster gedr ckt 3 Halten Sie den Taster weiterhin gedr ckt und schalten Sie das Ger t ein 4 Sobald die Status LED schnell blinkt lassen Sie die Taste los HINWEIS Die Wiederherstellung der Standardeinstellungen ist alternativ auch ber das Web Interface m glich G amp D UCON IP NEO 8 Statusanzeigen Statusanzeigen Frontseite Power System Red O Active Main Status e Abbildung 3 Rechter Ausschnitt der Frontansicht des Arbeitsplatzmoduls Die LEDs an der Frontseite des Arbeitsplatzmoduls geben Ihnen die M glichkeit den Betriebsstatus des Arbeitsplatzmoduls jederzeit zu kontrollieren Bereich LED Status Bedeutung Power Red an Das optionale Netzteil ist angeschlossen und liefert die erforderliche Spannung aus Das optionale Netzteil ist nicht angeschlossen oder die Verbindung mit dem Stromnetz nicht hergestellt Main an Das Netzteil ist eingeschaltet und liefert die erforderliche Spannung aus Das Netzteil ist ausgeschaltet oder die Verbindung mit dem Stromnetz nicht hergestellt System Active blinkt IP Zugriff ber Java Client oder IP Console Client aktiv aus Es fi
14. gure 2 Right section of the back panel of the user module Main Power Insert the supplied power cable Red Power Connect an optional power pack of the Power Set 12 series which estab lishes a second redundant power supply G amp D UCON IP NEO 4 Configuration before the start up Configuration before the start up If required adjust the network settings of the user module and the TCP port used for communicating with the G amp D IP Console Client software before the start up Thus all computers within the local network can access the user module Network port settings The network port settings can be adjusted to the settings of the local network The following table lists the default network port settings IP assignment static IP address 192 168 0 1 Subnet mask 255 255 255 0 Type of connection Auto How to change the network settings before the start up 1 5 Use a CATS or better twisted pair cable to connect any computer to the Network port of the user module Please ensure that the IP addresses of the computer and the user module are assigned to the same subnet You can use the IP address 192 168 0 10 for example Turn on the user module Start the computer s internet browser and enter the URL 192 168 0 1 into the address bar Enter the access data of the administrator account of the matrix switch in the Administration field of the web interface and click on
15. nd auf die Schaltfl che Zum Ger t bertragen G amp D UCON IP NEO 6 Starten des Java Clients Starten des Java Clients Die Rechner des IP Netzwerks k nnen den IP Arbeitsplatz ber den Java Client des Arbeitsplatzmoduls oder ber die Software G amp D IP Console Client aufrufen und bedienen HINWEIS Ausf hrliche Informationen zum Java Client und der mitgelieferten Software G amp D IP Console Client finden Sie in den separaten Handb chern So starten Sie den Java Client 1 Starten Sie auf einem Rechner des IP Netzwerks den Internet Browser und geben Sie in der Adresszeile folgende URL ein https lt IP Adresse_UCON IP eco gt z B https 192 168 0 1 2 Klicken Sie im Bereich Java Client der aufgerufenen Webapplikation auf die Schaltfl che Client starten 3 Der Java Client wird auf dem lokalen Rechner gestartet und zeigt die Login Maske 4 Geben Sie den Benutzernamen und das Kennwort Ihres Benutzerkontos ein und klicken Sie auf die Schaltfl che Anmelden 7 G amp D UCON IP NEO Standardeinstellungen wiederherstellen Standardeinstellungen wiederherstellen Rechts neben der Status LED befindet sich ein Reset Taster Verwenden Sie diesen Taster an der Frontseite des Arbeitsplatzmodul ggf zur Wiederherstellung der Standardeinstellungen HINWEIS Um die versehentliche Bet tigung des Tasters zu vermeiden ist dieser hinter einer Bohrung in der Frontblende platziert Verwend
16. nden Rechtsinhaber Impressum Guntermann amp Drunck GmbH 2015 Alle Rechte vorbehalten Version 1 01 19 02 2015 Firmware 1 0 000 00026 Guntermann amp Drunck GmbH Dortmunder Str 4a 57234 Wilnsdorf Germany Telefon 49 0 2739 8901 100 Telefax 49 0 2739 8901 120 http www GDsys de sales GDsys de i G amp D UCON IP NEO Inhaltsverzeichnis Inhaltsverzeichnis Sicherheitshinweise 000 Das Arbeitsplatzmodul UCON IP NEO ooie Lieferumfang Installation Erforderliches Zubeh r Anschluss der Kabel und Ger te Verbindung mit dem IP Netzwerk oooooooooooocccccononononononononcnnnonanononnnnncnnnannnnns Verbindung mit dem Matrixswitch dd Optional Anschluss der Ger te des lokalen Arbeitsplatzes STrOMIVEISOTBUDE vesciccccsicaccdccsecacaacedsnatacaedvanssdecedsnareddevesrbend de due ehe Konfiguration vor Erstinbetriebnahme Einstellungen der Netzwerkschnittstelle Konfiguration der Firewall des IP Netzwerkes Starten des Java Clients 0 000 0000 7 Standardeinstellungen wiederherstellen ooooocoonnoooocconccccoconononnconononononananonos 8 Statusanzeigen 2 detailed iaa 9 Frontseite ar IH Lunar 9 R ckseite skan ala 10 Technische A ni saa slasa Caa 11 G amp D UCON IP NEO ii Sicherheitshinweise Sicherheitshinweise Bitte lesen Sie die folgenden Sicherheitshi
17. ndet kein IP Zugriff statt Status blinkt Das Arbeitsplatzmodul ist betriebsbereit an Das Arbeitsplatzmodul wird gestartet 9 G amp D UCON IP NEO Statusanzeigen Ruckseite COM1 o uo o EE o MM e Network Keyb Mouse Monitor Transmission Red Power Abbildung 4 Linker Ausschnitt der R ckansicht des Arbeitsplatzmoduls An der Network und an der Transmission Schnittstelle befinden sich zus tzliche Sta tus LEDs die folgende Betriebszustande signalisieren Bereich LED Status Bedeutung Network gelb blinkt Aktivit tsanzeige gr n an Link hergestellt blinkt Link kann nicht hergestellt werden Transmission gelb an Port ist aktuell durch einen Benutzer belegt aus Port ist frei gr n an Verbindung zum Matrixsystem hergestellt aus Keine Verbindung zum Matrixswitch m glich G amp D UCON IP NEO 10 Technische Daten Technische Daten UCON IP NEO Video Signaltyp analoges Video Aufl sung max 1920 x 1440 75Hz Lokaler Anschluss Aufl sung max 1920 x 1200 60Hz IP Verbindung nativ bertragung Entfernung zwischen Arbeits max 300 Meter platzmodul und Target Modul Kommunikation Ethernet 10 180 bzw 1800 Mbit s Delaykompensation ja Arbeitspl tze Anzahl gesamt 2 konkurrierend Anzahl lokale Arbeitspl tze il Anzahl IP Arbeitspl tze 1 Hauptstromversorgung Typ internes Netzteil
18. nweise aufmerksam durch bevor Sie das G amp D Produkt in Betrieb nehmen Die Hinweise helfen Schaden am Produkt zu ver meiden und m glichen Verletzungen vorzubeugen Halten Sie diese Sicherheitshinweise f r alle Personen griffbereit die dieses Produkt benutzen werden Befolgen Sie alle Warnungen oder Bedienungshinweise die sich am Ger t oder in dieser Bedienungsanleitung befinden A Vorsicht vor Stromschlagen Um das Risiko eines Stromschlags zu vermeiden sollten Sie das Ger t nicht ffnen oder Abdeckungen entfernen Im Servicefall wenden Sie sich bitte an unsere Techniker Ziehen Sie den Netzstecker des Ger ts vor Installationsarbeiten Stellen Sie vor Installationsarbeiten sicher dass das Ger t spannungsfrei ist Ziehen Sie den Netzstecker oder die Spannungsversorgung am Ger t ab St ndigen Zugang zu den Netzsteckern der Ger te sicherstellen Achten Sie bei der Installation der Ger te darauf dass die Netzstecker der Ger te jederzeit zug nglich bleiben L ftungs ffnungen nicht verdecken L ftungs ffnungen verhindern eine berhitzung des Ger ts Verdecken Sie diese nicht Stolperfallen vermeiden Vermeiden Sie bei der Verlegung der Kabel Stolperfallen Geerdete Spannungsquelle verwenden Betreiben Sie dieses Ger t nur an einer geerdeten Spannungsquelle Verwenden Sie ausschlie lich das G amp D Netzteil Betreiben Sie dieses Ger t nur mit dem mitgelieferten oder in der Bedienungs anleitung aufgef hrten Netz
19. r Rechner des IP Netzwerks mit dem Web Interface sowie die bertragung des Java Clients auf die Rechner des Netzwerks abgewickelt Port 27998 Die Software G amp D IP Console Client kommuniziert ber diesen Port mit dem Arbeitsplatzmodul Innerhalb des Web Interfaces kann die Einstellung dieses Ports ge ndert werden s u WICHTIG Stellen Sie sicher dass sowohl die Rechner auf welchen das Web Inter face der Java Client oder die Software G amp D IP Console Client angewendet werden als auch das Arbeitsplatzmodul berechtigt sind Verbindungen ber den Port 443 und oder den Port 27998 aufzubauen Falls der Port 27998 bereits durch eine andere Anwendung belegt ist kann der Port durch den Administrator ge ndert werden So ndern Sie den Port der TCP Verbindung zur Kommunikation mit der Software G amp D IP Console Client 1 Starten Sie auf einem Rechner des IP Netzwerks den Internet Browser und geben Sie in der Adresszeile folgende URL ein https lt IP Adresse_UCON IP NEO gt z B https 192 168 0 1 2 Geben Sie im Bereich Administration des Web Interfaces die Zugangsdaten des Administratorkontos ein und klicken Sie auf die Schaltflache Anmelden 3 Klicken Sie auf die Schaltflache Konfiguration Die aktuellen Konfigurationsein stellungen werden im Web Interface angezeigt 4 Geben Sie auf der Registerkarte System die von Ihnen gew nschte Port Nummer in der Zeile TCP Port ein Klicken Sie abschlie e
20. teil Betreiben Sie das Ger t ausschlie lich im vorgesehenen Einsatzbereich Die Ger te sind f r eine Verwendung im Innenbereich ausgelegt Vermeiden Sie extreme K lte Hitze oder Feuchtigkeit 1 G amp D UCON IP NEO Das Arbeitsplatzmodul UCON IP NEO Das Arbeitsplatzmodul UCON IP NEO Mit dem Arbeitsplatzmodul UCON IP NEO erweitern Sie einen KVM Matrixswitch der CATCenter Serie um einen IP Arbeitsplatz Das Arbeitsplatzmodul wird tiber eine Twisted Pair Verkabelung mit einem IP Netz werk verbunden Die Rechner innerhalb des Netzwerks k nnen den IP Arbeitsplatz ber den Java Client des Arbeitsplatzmoduls oder ber die mitgelieferte Software G amp D IP Console Client aufrufen und bedienen Zus tzlich besteht die M glichkeit einen lokalen Arbeitsplatz bestehend aus Moni tor Tastatur und Maus an das Arbeitsplatzmodul anzuschlie en Lieferumfang 1 x Arbeitsplatzmodul UCON IP NEO 1 x Stromversorgungskabel PowerCable 2 Standard 1 x Rackmount Set 19 RM Set 435 1HE 1 x Handbuch Installation und Bedienung 1 x CD UCON IP NEO HINWEIS Die CD beinhaltet die Software IP Console Client sowie PDF Fas sungen der Handb cher Web Interface Java Client und IP Console Client G amp D UCON IP NEO 2 Installation Installation Erforderliches Zubehor Ein Twisted Pair Kabel der Kategorie 5 oder h her zum Anschluss des Arbeits platzmoduls an das IP Netz
21. ver the ventilation openings Ventilation openings prevent the device from overheating Do not cover them Avoid tripping hazards Avoid tripping hazards while laying cables Only use a grounded voltage source Operate this device by using a grounded voltage source Use only the provided G amp D power pack Operate this device with the provided G amp D power pack or with the power pack listed in the manual Operate the device only in designated areas The devices are designed for indoor use Avoid exposure to extreme cold heat or humidity 1 G amp D UCON IP NEO The user module UCON IP NEO The user module UCON IP NEO The user module UCON IP NEO expands a KVM matrix switch of the CATCenter series by an IP console A twisted pair cable links the user module to an IP network The computers within the network call and operate the IP console via the Java client or the supplied G amp D IP Console Client software The user module can also be provided with a local console consisting of monitor keyboard and mouse Package contents x user module UCON IP NEO 1 x power cable PowerCable 2 Standard x rack mount set 19 RM Set 435 1HE 1 x manual Installation and Operation 1 x CD UCON IP NEO NOTE The CD includes the IP Console Client software and PDF versions of the Web Interface Java Client and IP Console Client manuals G amp D UCON IP NEO 2 Installation
22. werk Ein Twisted Pair Kabel der Kategorie 5 oder h her zum Anschluss des Arbeits platzmoduls an den Matrixswitch Anschluss der Kabel und Gerate coM1 0 o MM gt Bi Network Keyb Mouse Monitor Transmission Red Power Abbildung 1 Linker Ausschnitt der R ckansicht des Arbeitsplatzmoduls Verbindung mit dem IP Netzwerk WICHTIG Zur erstmaligen Konfiguration der Netzwerkeinstellungen des Arbeits platzmoduls schlie en Sie einen beliebigen Rechner an die Network Schnittstelle des Arbeitsplatzmoduls an Weiterf hrende Information zu diesem Thema finden Sie im Kapitel Konfiguration vor Erstinbetriebnahme auf Seite 5 Network Stecken Sie ein als Zubeh r erh ltliches Twisted Pair Kabel der Kategorie 5 oder h her ein und stellen Sie eine Verbindung mit dem IP Netzwerk her Verbindung mit dem Matrixswitch Transmission Stecken Sie ein als Zubeh r erh ltliches Twisted Pair Kabel der Katego rie 5 oder h her ein Verbinden Sie das andere Ende des Kabels mit einer Console Schnittstelle des Matrixswitches der CA TCenter Serie Optional Anschluss der Gerate des lokalen Arbeitsplatzes Keyb Schlie en Sie die PS 2 Tastatur des lokalen Arbeitsplatzes an Mouse Schlie en Sie die PS 2 Maus des lokalen Arbeitsplatzes an Monitor Schlie en Sie den Monitor des lokalen Arbeitsplatzes an HINWEIS Die Schnittstelle COM1 wird ausschlie lich zur Wartung des Ger tes