PowerLogic Ethernet Gateway EGX300
Contents
1. AAA 1 169 254 50 2 0 0 0 0 3 o p p o 4 0 0 o 0 5 o Lo o Lo 6 o o 0 o 7 b 0 0 0 e o o o 0 9 o 0 o D 10 o 0 0 0 11 0 0 o o 12 o 0 0 0 13 0 0 0 o 14 o 0 0 o 15 0 o p o 16 o o o 0 169 254 0 20 169 254 0 30 11 Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Configuration 11 2011 Liste des appareils EGX Avant de commencer gardez a l esprit que vous ne devez pas utiliser les adresses esclaves s rie 1 a 16 en mode de transmission automatique sur une guirlande utilisant plusieurs protocoles par exemple une guirlande qui comporte des appareils utilisant le protocole PowerLogic et d autres utilisant le protocole Modbus RTU Jbus Connexion d appareils a une passerelle EGX La Figure 8 et la Figure 9 montrent les possibilit s de connexion des appareils la passerelle EGX Pour ajouter ces appareils la liste des appareils suivez la proc dure d crite a la section Configuration de la liste des appareils page 13 Figure 8 Topologie Appareils esclaves s rie uniquement Connexion Ethernet Pages Web de l EGX300 Connexion RS 485 Appareils esclaves s rie Figure 9 Topologie Appareils esclaves s rie et appareils distants Connexion Ethernet Pa
2. Device Logging Logging Interval 15 a Minutes Logging Purge Data Device Name Device Type select all select all Customize Building Main CM4000 v topics Building West Panel CM2000 Y topics Building East Panel CM3000 topics Building North Panel PM800 topics Apply Topics for each device may be individually selected for logging 1 From the Device Logging page click topics link for the desired device 2 See Figure 14 and check the topic s you Selects the topics to log want to log To select all topics click select all To deselect all topics click clear To select the default topics click Defaults 3 Click Apply Saves the topic selection to log 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Device Log Export E mail Export 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup Figure 14 Topic Selection Page Device Name Device Type Building North Panel PMEOO 3 Enabled on Topic Name intervals 57024 select all clear days 594 Apparent Energy kVAh Logging Interval 15 minutes Real Energy kWh Reactive Energy kVARh Apparent Power Total kVA Real Power Total kW Reactive Power Total kV AR Dmd Real Pwr kW Dmd Reactive Pwr kVAR Demand Current A HAE Demand Current B Demand Current C
3. 1 169 254 50 2 0 0 0 Mio 3 o 0 o 0 4 0 0 0 0 5 0 Lo o o 6 0 0 0 0 7 o 0 o 0 8 o 0 o 0 9 0 Lo o 0 10 o o 0 0 11 0 Lo 0 Lo 12 0 0 0 0 13 0 0 o 0 14 o o 0 0 15 0 0 o 0 16 0 0 0 0 169 254 0 20 169 254 0 30 2011 Schneider Electric Reservados todos los derechos 11 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Configuraci n 11 2011 Lista de dispositivos de la EGX Antes de comenzar tenga en cuenta que no debe utilizar las direcciones serie esclavas 1 o 16 en un modo de transmisi n Autom tico en un bus de comunicaciones serie con protocolos mixtos por ejemplo una sola conexi n en bus de comunicaciones serie con algunos dispositivos que usen el protocolo PowerLogic y otros que usen el protocolo Modbus RTU Jbus Conexi n de dispositivos a una EGX La Figura 8 y la Figura 9 ilustran la manera en que los dispositivos se conectan a la EGX Para agregar esos dispositivos a la Lista de dispositivos siga los pasos que se indican en Configuraci n de la lista de dispositivos en la p gina 13 Figura 8 Topolog a S lo dispositivos esclavos en serie Conexi n Ethernet P ginas web de la EGX300 Dispositivos esclavos en serie Figura 9 Topolog a Dispositivos esclavos y remotos en serie Conexi n Ethernet P ginas web de
4. Device Logging Pages provide graphic and table representations of selected device log data For more details on configuring device logging see Device Logging on page 17 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Single Device Pages 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Monitoring Single Device pages provide graphic and table representations of data logged from a single device 1 From the Monitoring menu click Device Expands tree to show available device logging Logging choices 2 Under Device Logging click Single Expands tree to show available devices that Device Pages have logged data available for viewing 3 Select a device from the Device Logging Displays the device log for the selected device list 4 To view a data range select a range from Plots the selected data range the data range drop down list 5 Hold down the left mouse button and drag Zooms in on the selected graph area a selection box around a graph area to zoom in on it 6 To return to the original full view type Z on The view zooms out your keyboard or double click on the graph 7 Click Data Points to view the selected Opens the selected Interval Data Log table interval data log table see Figure 37 below 8 To view different topics click New Enables the display of the selected topic s Topic s Enable the check box es of the to
5. 2011 Schneider Electric All Rights Reserved 45 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Monitoring 11 2011 Figure 40 Multiple Devices Single Topic Trend Page Real Energy kWh Last Full Day 7 EM Building North Panel MM Building East Panel 13 12 2010 02 16 06 00 00 2010 02 16 12 00 00 2010 02 16 18 00 00 2010 02 17 00 00 00 2010 02 17 06 00 00 Select an area to zoom Press Z or double click to undo zoom Dashboards The EGX supports four categories of dashboards that display energy consumption information aggregated over time Table 17 lists the dashboards and their subsets Table 17 Dashboard Types Dashboard Subset Past Day by Hours Present Day by Hours Present Day over Past Day by Hours Past Week by Days Present Week by Days Present Week over Past Week by Days Past Month by Days Present Month by Days Present Month over Past Month by Days Past Quarter by Weeks Present Quarter by Weeks Present Quarter over Past Quarter by Weeks Trailing 13 Weeks by Weeks Past Year by Months Present Year by Months Present Year over Past Year by Months NOTE Requires each device data log file to have the capacity for two years of historical data See Interval Data Logging on page 17 for more information Trailing 12 Months by Month 46 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 PowerL
6. Valeurs par d faut Appliquer 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Configuration Tableau 3 Param tres Ethernet avanc s de la passerelle EGX Dur e de vie D termine le nombre de routeurs par lesquels un 1 255 sauts paquet TCP peut passer Par d faut 60 sauts Maintien de la D compte permettant de d tecter lorsqu un appareil 0 65 000 s connexion TCP sur une connexion inactive devient indisponible du Par d faut fait d un red marrage d une mise hors tension etc 30 secondes Entrez la valeur 0 pour d sactiver cette fonction D lai d attente Permet de sp cifier le temps pendant lequel la 0a60s BootP passerelle EGX doit attendre l assignation de son Par d faut adresse IP par un serveur BootP l adresse IP par 15 secondes d faut est utilis e si aucune adresse IP n est attribu e apr s le d lai d attente D lai d attente du Permet de sp cifier le temps pendant lequel les 0 65 000 minutes cache ARP entr es sont conserv es dans la table ARP Address Par d faut Resolution Protocol 15 minutes Serveur FTP D termine si le serveur FTP s initialise pendant le D sactiv ou Activ d marrage Par d faut Activ D lai d inactivit de D compte permettant de fermer une connexion FTP 30 900 s la connexion FTP apr s le temps d
7. Appuyez sur CTRL A puis sur CTRL C S lectionne toutes les donn es puis les copie dans le Presse papiers Colle les donn es dans une feuille de calcul Excel Ouvrez Excel et appuyez sur CTRL V Enregistrement d un tableau de bord Si vous ne souhaitez pas passer par le menu principal chaque fois que vous devez acc der un tableau de bord utilisez l une des m thodes d enregistrement d crites dans le Tableau 18 Tableau 18 Enregistrement d un tableau de bord Description Valeur Favori de navigateur Permet aux utilisateurs d acc der au tableau de bord enregistr sur l ordinateur sur lequel le favori a t cr Suivez les instructions pour cr er un favori dans le navigateur de votre choix Lien vers la documentation Permet tous les utilisateurs EGX d acc der un tableau de bord enregistr depuis la page Documentation Voir Liens vers la documentation page 26 pour configurer l acc s par URL Courrier lectronique Permet aux utilisateurs d envoyer l URL d un tableau de bord dans le corps d un message lectronique Chaque destinataire du message lectronique doit disposer d un compte utilisateur Point d acc s syst me 48 EGX pour afficher le tableau de bord Voir Comptes utilisateur page 28 L EGX peut d tecter et fournir des liens vers les passerelles EGX300 et autres appareils Schneider Electric connect s au r seau
8. Tableau 10 Param tres SNTP open O eon O O v D calage horaire L heure est d finie en fonction de la valeur UTC 12 00 UTC 13 00 de temps universel coordonn UTC Par d faut UTC GMT Universal Time Coordinated s lectionn e Activer le r glage automatique de l heure d t Permet de d finir le d but et la fin de Premier Cinqui me ou l heure d t Dernier Dimanche Samedi Janvier D cembre 0 00 23 00 Par d faut D bute le deuxi me dimanche de mars 2 00 Termine le deuxi me dimanche de novembre 2 00 P riode de scrutation Adresse IP du serveur NTP primaire Adresse IP du serveur NTP secondaire Contr le la fr quence laquelle la passerelle EGX contacte le serveur NTP pour obtenir l heure correcte Adresse IP du serveur NTP primaire que la passerelle EGX contacte pour obtenir l heure correcte Adresse IP du serveur NTP secondaire que la passerelle EGX contacte pour obtenir l heure correcte 1 heure 1 semaine Par d faut 1 semaine 0 0 0 0 255 255 255 255 Par d faut 0 0 0 0 0 0 0 0 255 255 255 255 Par d faut 0 0 0 0 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Passerelle Ethernet PowerLogic EGX300 Configuration Param tres SNMP Filtrage Modbus TCP IP 2011 Schneider Electric Tous droits r serv s La passerelle EGX prend en charge le protocole SNMP qui permet un administrat
9. 5 W hlen Sie den Ger tetyp aus der Auswahl des Ger tetyps Dropdown Liste aus 6 Geben Sie in das Textfeld Eingabe der Ger tebezeichnung Ger tebezeichnung den Namen des Ger ts ein 7 Geben Sie in das Textfeld Lokale ID die Eingabe der lokalen Adresse des Ger ts Adresse des seriellen Slave Ger tes ein wenn es am seriellen Port angeschlossen ist bzw die Adresse die Sie f r den Zugriff auf ein entferntes Ger t verwenden m chten 8 Geben Sie in das Textfeld Fern ID die Eingabe der Adresse des entfernten Ger ts Adresse des entfernten Ger ts ein 9 Wiederholen Sie die Schritte 4 bis 8 bis Eingabe aller angeschlossenen Ger te alle Ger te eingegeben sind 10 Klicken Sie auf bernehmen Aktualisierung der Einstellungen in der Ger teliste Dieser Konfigurationsparameter kann nur ver ndert werden wenn die Datenaufzeichnung f r das zu aktualisierende Ger t deaktiviert ist Siehe Ger teaufzeichnung auf Seite 17 Abbildung 10 Seite Ger teliste Ger teliste Anzahl anzuzeigende Ger te 8 53 Ger tetyp Ger tebezeichnung Lokale ID PM800 y PM800_Bldg1_Feeder1 3 M4000 8 CM4_Bldgt_Maint 4 CM2000 g CM2_Bldg2_Feeder2 5 PM9c PM9c_Bldg2_Feeder2 6 Sepam 2000 E Sepam2_Bldg 2_CB_1 7 Sepam Series 40 M Sepam4_Bidgti_CB 2 8 Model98 modbus g Model98_Bldg1_Switchgeart 9 Modbus hal Erkennung Ubernehmen 2011 Schneider Electric
10. Building North Panel 166 132 0 943 kapazitiv Um eine Echtzeit Trenddarstellung mehrerer Ger te anzuzeigen rufen Sie das berwachungsmen auf und w hlen Sie Echtzeitdaten gt Trendverfolgung aus W hlen Sie im berwachungsmen Echtzeitdaten aus Erweiterung der Datenbauman sicht f r die Auswahl der Echtzeit Datenoptionen 2 W hlen Sie Trendverfolgung aus Erweiterung der Datenbaumansicht f r die Auswahl der Echtzeit Trendverfolgungsoptionen 3 W hlen Sie Echtzeit Trendverfolgung aus Einblendung der Setup Seite f r die Echtzeit Trendverfolgung 4 Wahlen Sie bis zu vier Ger te aus der Liste Verf gbare Auswahl von Ger ten f r die Ger te aus Trendverfolgung 5 W hlen Sie ein oder mehrere Gr en aus der Liste Auswahl von Gr en f r die Verf gbare Gr en aus Trendverfolgung HINWEIS Es stehen nur die Gr en zur Trendverfolgung zur Verf gung die alle ausgew hlten Ger te gemeinsam haben Die maximale Anzahl der Gr en f r die Trendverfolgung h ngt von der Anzahl der ausgew hlten Ger te ab Das Produkt aus der Anzahl der ausgew hlten Ger te und Gr en muss kleiner als oder gleich 8 sein 6 Klicken Sie auf Weiter um die Anzeigeseite Echtzeit Einblendung der Anzeigeseite Trendverfolgung einzublenden Echtzeit Trendverfolgung 7 Um die Trendverfolgungsparameter festzulegen fahren M glichkeit zur Einstellung der Sie mit d
11. Demand Current A Last Demand Current B Last Demand Current C Last Current A Current B Current C Current Avg Voltage A B Voltage B C Voltage C A Voltage L L Avg Voltage A N Voltage B N Voltage C N Voltage L N Avg This option allows you to export device logs in three ways by E Mail FTP or HTTP Each method is described in the following sections NOTE If the E Mail FTP or HTTP servers are not located on the same Ethernet network segment as the EGX be sure the EGX Default Gateway is properly configured See Ethernet and TCP IP Settings on page 5 1 From the Setup page click Device Log Opens the Device Log Export page Export 2 Select E Mail as the mode of transport Opens the E Mail device log export options 3 Check the Incremental check box Selects only new interval data logged since the last successful data export NOTE If the transport is scheduled for Hourly or Logging interval the incremental check box will be automatically selected NOTE If the Incremental check box is not selected the whole log file is sent via e mail attachment on each scheduled interval 4 Select Hourly Daily Weekly Monthly or Selects how often the data logs are sent Logging interval 19 PowerLogic Ethernet Gateway EGX300 Setup 20 63230 319 216B2 11 2011 5 Depending on
12. 4 Klicken Sie auf den entsprechenden Einblendung des ausgew hlten Men punkts Men punkt in der Men leiste Abbildung 2 EGX Startseite Schneider PowerLogic EGX300 D Electric Stertsete Unterlagen berwachung Steuerung Men leiste Firmwareversion 3 800 Copyright 2005 2010 Schneider Electric Alle Rechte vorbehalten Benutzer g Wir empfehlen dass Sie sich immer dann abmelden wenn Sie keinen Zugang zum EGX ben tigen Klicken Sie auf Logout oder schlie en Sie einfach Ihren Browser um sich von der EGX Sitzung abzumelden 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 EGX BENUTZEROBERFL CHE BERBLICK 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 EGX Benutzeroberfl che berblick Die EGX Benutzeroberfl che besteht aus mehreren Webseiten die f r die Ger te berwachung und steuerung sowie f r die EGX Diagnose und Einrichtung benutzt werden Tabelle 1 enth lt eine Beschreibung jeder Webseite Tabelle 1 EGX Seiten EGX Webseite Beschreibung as Ethernet amp TCP IP Konfiguration der Ethernet und TCP IP Einstellungen Serielle Schnittstelle Verbindungen zu entfernten Ger ten EGX Ger teliste Ger teaufzeichnung Ger teprotokollexport Datum und Uhrzeit SNMP Parameter Modbus TCP IP Filter Unterlagenlinks Benutzerkonten Webseitenzugriff Pr ferenzen Anzeigbare Ger tet
13. Aufzeichnung Ihrer Anmeldedaten f r den SMTP Server Senden einer Test E Mail und oder bernehmen der E Mail Einstellungen f r den Protokollexport Abbildung 15 Seite Ger teprotokollexport E Mail Ger teprotokollexport bertragung Deaktiviert E Mail Inkrementell O FTP O HTTP Zeitplan Aufzeichnungsintervall St ndlich T glich Tageszeit 00 00 J Tag der Woche Tag des Monats E w chentlich Monatlich E Mail Parameter Von Adresse Zu Adresse Server IP Adresse 0 0 0 Server TCP Port 25 SMTP Server erfordert Anmeldung Benutzername Kennwort eeeeee Manueller Export Test E Mail 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Setup FTP Export 1 Klicken Sie auf der Setup Seite auf Einblendung der Seite f r den Ger teprotokollexport Ger teprotokollexport 2 W hlen Sie FTP als bertragungsart Einblendung der Optionen f r den Export des Ger teprotokolls ber FTP 3 Aktivieren Sie das Kontrollk stchen Inkrementell Hiermit werden nur neue seit dem HINWEIS Wenn die bertragung St ndlich oder letzten erfolgreichen Datenexport zum Aufzeichnungsintervall geplant ist wird das aufgezeichnete Daten f r das Senden Kontrollk stchen Inkrementell automatisch ausgew hlt aktivi
14. NOTE Applying changes to the Advanced Ethernet Settings page does not save changes to the Ethernet amp TCP IP page 4 Click OK to approve the changes and to The EGX reboots reset the EGX Figure 4 Advanced Ethernet Settings Page Advanced Ethernet Settings Se ee oo i Time To Live 60 1 255 Hops TCP Keep Alive fo Seconds BootP Timeout 5 Seconds ARP Cache Timeout 5 Minutes FTP Server enabled El FTP Connection Idle Time 20 Seconds HTTP Connection Idle Time 6 Seconds HTTP Port Number 80 1 65535 HTTPS Port Number 0 1 65535 n 100 HTTP Maximum Keepalives Modbus TCP IP Server Connections 32 y Modbus Broadcast Disabled A Modbus TCP Proxy Enabled H ModbusTCP IP Client Timeout ls y Seconds ModbusTCP IP Client Connection Timeout lay Seconds ModbusTCP IP Server Connection Idle Time op Seconds Defaults Apply 6 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup Table 3 EGX Advanced Ethernet Settings option Desenpion sim Identifies the number of routers a TCP packet o 255 hops 1 can pass Default 60 hops TCP Keep Alive A timer that detects when a connected device 0 to 65 000 seconds on an idle connection becomes unavailable Default 30 seconds due to events such as a reboot or shutdown A settin
15. PRECAUCI N indica una situaci n de riesgo potencial que si no se evita puede causar lesiones moderadas o leves PRECAUCION PRECAUCION sin el simbolo de alerta de seguridad indica una situaci n de riesgo potencial que si no se evita puede causar dafios materiales NOTA Proporciona informacion adicional para aclarar o simplificar procedimientos S lo el personal cualificado puede instalar manipular y revisar el equipo electr nico asi como realizar el mantenimiento de este Schneider Electric no asume ninguna responsabilidad de las consecuencias que se deriven de la utilizaci n de este manual Este equipo ha sido probado y cumple los limites establecidos para los dispositivos digitales Clase A segun la secci n 15 de la normativa de la FCC Comisi n Federal de Comunicaciones de los EE UU Estos limites se establecen para proporcionar la protecci n adecuada contra interferencias que puedan da ar el equipo cuando este se utiliza en un entorno comercial Este equipo genera utiliza y puede emitir energia de radiofrecuencia y si no se instala y utiliza siguiendo las indicaciones del manual de instrucciones puede provocar interferencias que afecten a las radiocomunicaciones Si se utiliza en una zona residencial las interferencias podrian causar da os En tal caso el usuario es el responsable de corregir dichas interferencias por su propia cuenta y riesgo Este aparato digital Clase A cumple con la normativ
16. Verbindungen zu entfernten Ger ten auf Seite 10 5 Geben Sie eine neue Ger tebezeichnung in das Damit wird das Ger t umbenannt Textfeld Name ein 6 Aktivieren Sie das Kontrollk stchen Speichern Auswahl der zu speichernden oder zu neben dem Ger t das Sie in der Ger teliste entfernenden Ger teeintr ge bzw speichern m chten Aufheben dieser Auswahl 7 Klicken Sie auf der Seite Ger teerkennung auf Damit wird die Ger tekonfiguration bernehmen aller f r die Speicherung markierten Ger te in der Ger teliste gespeichert 15 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Abbildung 12 Ger teerkennung Ger teerkennung 2011 09 26 16 16 02 PM6 modbus PM6 modbus PM650 1 22 43 3 125 G ltig CM3000 CM3000 fr CM3350 44 ce om Giitig CM4000 CM4000 CM4250 AS 5 0 G kig Erkennung starten Tabelle 8 Optionen der Ger teerkennung Start Endadresse Legt den Modbus Adressenbereich fest 1 bis 247 der f r die Erkennung von Ger ten am Werkeinstellung Start 1 seriellen Port des EGX benutzt wird Ende 10 Speichern Damit k nnen Sie das ausgew hlte Ger t Aktiviert oder Deaktiviert in der Ger teliste speichern Werkeinstellung Aktiviert Verbindung Anzeige der Verbindung auf der das Ger t Serielle Schnittstelle oder IP erkannt oder berpr ft wurde Adresse f r die berpr fung
17. acheminant les journaux de 255 255 255 255 donn amp es REMARQUE Contactez votre administrateur r seau si vous ne connaissez pas l adresse du serveur FTP File Transfer Protocol 7 Dans la zone de texte Port TCP du serveur saisissez le Definit le port d exp dition port du serveur FTP Par d faut 21 8 Saisissez le r pertoire dans la zone de texte R pertoire Permet de saisir les informations relatives au r pertoire du serveur distant 9 Saisissez votre nom d utilisateur et votre mot de passe M morise vos identifiants de dans les zones de texte connexion au serveur 10 Activez l option Passif Permet de s lectionner le mode passif pour le transfert FTP 11 Cliquez sur Test FTP pour effectuer un test des param tres Envoie un fichier de test au FTP que vous avez d finis ou cliquez sur Appliquer serveur et r pertoire FTP et ou REMARQUE Le bouton Test FTP valide les param tres aPplique les param tres FTP d exportation du journal par FTP et transf re un fichier de test le bouton Appliquer valide uniquement les param tres Figure 16 Page Exporter le journal de l appareil par FTP Exporter le journal de l appareil Transport D sactiv Courrier lectronique FIP O HTTP Incr mentale Planifier Intervalle d enregistrement O Horaire Quotidien Hebdomadaire O Mensuel Heure 00 00 a Jour de la semaine Jour du mois 1 Ed Param tres FTP Adresse I
18. l tape Sp cifie quel moment les journaux de pr c dente s lectionnez l heure le jour de donn es sont achemin s la semaine et ou le jour du mois Dans les zones de texte Adresse IP du D finit l adresse IP du serveur acheminant les serveur saisissez l adresse du serveur journaux de donn es HTTP REMARQUE Contactez votre administrateur r seau si vous ne connaissez pas l adresse du serveur HTTP Dans la zone de texte Port TCP du D finit le port TCP d exp dition serveur saisissez le port du serveur Par d faut 80 HTTP REMARQUE Si vous souhaitez utiliser une connexion SSL pour l exportation entrez le num ro de port TCP du serveur HTTPS habituellement 443 Dans la zone de texte Chemin saisissez Ins re le chemin du script serveur le chemin du script serveur que le serveur Web doit ex cuter lorsque la passerelle EGX lui transmet des donn es Dans le champ Nom de champ saisissez Permet la passerelle EGX de passer des le nom sous lequel le serveur Web doit fichiers un script de serveur Web existant attendre le nom de fichier REMARQUE Si ce crit re est sans objet utilisez la valeur par d faut datafile1 10 Dans le champ Nom d h te saisissez le Identifie un h te sp cifique sur le serveur Web nom de domaine de l h te si ce serveur h berge plusieurs domaines pour une m me adresse IP Vide par d faut 11 Saisissez votre nom d utilisateur et votre M amp moris
19. 2011 Schneider Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Appendix B Supported Device Types Table 20 EGX300 Supported Device Types Device Group Devices SIM10M SIM6BZ Soft Starters ATS48 MVSS RVSS Temperature Humidity Light Sensors ZED THL M Trip Units Micrologic A Micrologic E Micrologic H Micrologic P Other Acti9 Multicontrol 2011 Schneider Electric All Rights Reserved 61 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Appendix B Supported Device Types 11 2011 62 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Index A access levels to the EGX 25 accessing the EGX over a network 2 additional resources 1 analog gauge range 38 ARP address resolution protocol 8 audit trail 33 maintenance log 34 Syslog box 34 basic readings settings 37 C communications check 55 automated 55 manual 55 connecting devices 12 control 49 custom web pages setup 30 D dashboards 46 data log error codes 43 retrieved via ftp 43 retrieving 42 data log format 42 data points button interval data log 44 date and time setup 23 device discovery 15 device list EGX 12 device log export setup 19 device logging 17 40 device registers reading 54 device types supported 60 diagnostics 50 documentation links setup 26 documentation page 49 duplicate IP address detection 8 E EGX device list 12
20. 4 En la columna Nivel de acceso Selecciona el nivel de acceso para la correspondiente seleccione S lo lectura o Completo direcci n IP Cuando se establece como S lo lectura s lo se permiten los siguientes c digos de funci n Modbus TCP IP Decimal 1 2 3 4 7 8 11 12 17 20 24 43 100 Hexadecimal 01 02 03 04 07 08 0B 0C 11 14 18 2B 64 O 2011 Schneider Electric Reservados todos los derechos 25 Pasarela Ethernet EGX300 de PowerLogic Configuraci n Vinculos de documentaci n 26 63230 319 216B2 11 2011 5 Repita los pasos 3 y 4 para agregar Contin a a adiendo direcciones IP para el filtrado m s direcciones IP i 6 Haga clic en Aplicar Guarda la lista de filtrado de direcciones Modbus TCP IP Figura 21 P gina Filtrado de Modbus TCP IP Filtrado de Modbus TCP IP Activar filtrado 7 Y a i a Nivel de acceso Solo lectura S lo lectura S lo lectura al S lo lectura EFFEFEEFEEE AAA AAA AAA AAA Aplicar La EGX admite dos tipos de v nculos de documentaci n 1 acceso a archivo local documentaci n guardada incorporada en la EGX 2 acceso URL externo NOTA Los documentos de archivos locales que desee que aparezcan en la p gina web Documentaci n deber colocarlos en la carpeta www documentation documentaci n de la EGX utilizando FTP 1 En el men Configuraci n haga clic en Abre l
21. Actualizar al abrir archivo La EGX se tiene que configurar para enviar los registros de datos a una direcci n de correo electr nico Para obtener m s informaci n consulte Exportaci n por correo electr nico en la p gina 19 Es necesario configurar la EGX para que pueda entregar registros cronol gicos de datos a un servidor web Para obtener m s informaci n consulte Exportaci n por HTTP en la p gina 22 O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Supervision Paginas de resumen de dispositivos Las vistas de Resumen de dispositivos proporcionan res menes de uno o mas dispositivos seleccionados En el men Supervisi n haga clic en Registro de Ampl a el rbol para mostrar las dispositivos opciones de registro de dispositivos En Registro de dispositivos haga clic en P ginas de resumen de dispositivos En P ginas de resumen de dispositivos haga clic Abre la p gina de configuraci n de la en Varios dispositivos Unico tema p gina Varios dispositivos Unico tema Seleccione un dispositivo de la lista Dispositivos Selecciona los dispositivos para las disponibles opciones de resumen NOTA Se pueden seleccionar cuatro dispositivos como m ximo Seleccione un tema de la lista Temas Selecciona el tema que se visualizar disponibles para cada dispositivo seleccionado NOTA Solo estar n disponibles aquel
22. Einstellung des Unterlagenlinktitels der auf der Titel des Unterlagenlinks ein Unterlagenseite erscheinen soll 5 Klicken Sie auf bernehmen Aktualisierung der Einstellungen f r die EGX Unterlagenlinks 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Setup Abbildung 22 Seite Unterlagenlinks Unterlagenlinks Aktiviert Neues Fenster Dateiname Link Text Unterlagerwerzeichnis leer Aktiviert Neues Fenster URL Link Text 4 a http a a http www PowerLogic com PowerLogic com a ic http www Schneider Electric com Schneider Electric com HINWEIS Informationen ber den Zugriff auf die geladenen Unterlagen finden Sie unter Unterlagen auf Seite 49 27 PowerLogic Ethernet Gateway EGX300 Setup Benutzerkonten 28 63230 319 216B2 11 2011 EGX Benutzern werden Benutzernamen und Kennw rter zugewiesen Jeder Benutzer geh rt zu einer Gruppe und jede Gruppe besitzt Zugriffsrechte auf die EGX Webseiten die vom EGX Administrator zugewiesen wurden HINWEIS Zwei Benutzerkonten sind voreingestellt Administrator voreingestelltes Kennwort Gateway und Guest Gast voreingestelltes Kennwort Guest 1 Klicken Sie im Setup Men auf Einblendung der Seite Benutzerkonten Benutzerkonten 2 Wenn Sie einen Gruppennamen ndern wollen Eingabe eines
23. O ASCII 1 Dans le menu Diagnostics cliquez sur Ouvre la page Lecture de registres d appareils Lecture de registres d appareils 2 Saisissez l identification locale de l appareil Permet d entrer les registres lire sur l appareil ou effectuez une s lection dans la liste sp cifi des appareils d finis l adresse de d part et le nombre de registres lire 3 S lectionnez un type de donn es S lectionne le type de donn es appropri 4 Pour modifier l affichage des donn es S lectionne le mode d affichage des valeurs dans la colonne Valeur s lectionnez Decimal Hexadecimal Binaire ou ASCII 5 Cliquez sur Lire Lit les registres d appareils en fonction de la configuration s lectionn e Tableau 19 Param tres de lecture de registres d appareils EGX Ne Valeur par option Demi Vea Nom d appareil S lectionne un appareil a lire dans la liste des appareils ajout s pr c demment Pour lire un appareil non d fini dans la liste des appareils entrez son num ro d identification locale Identification de Adresse identification locale de l appareil lire 1 l appareil Registre de d part Premier registre a lire 1000 Nombre de registres Nombre de registres lire 1 125 Colonne Registre Liste des num ros de registres Colonne Valeur Liste des donn es enregistr es dans un registre Les valeurs r cup r es d pendent de l appareil connect la passerell
24. PowerLogic Ethernet Gateway EGX300 Setup Abbildung 7 Verbindungen zu entfernten Ger ten Verbindungen zu entfernten Ger ten 1 169 1 254 o 50 2 0 0 0 0 3 0 0 0 0 4 0 Ho 0 0 5 0 0 0 0 6 0 0 0 0 7 0 0 0 0 8 0 0 0 0 9 0 0 0 10 0 0 0 0 11 0 o 0 0 12 0 0 0 0 13 0 0 0 0 14 0 0 0 0 15 0 0 0 0 16 0 0 0 0 169 254 0 20 169 254 0 30 11 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 EGX Ger teliste Bedenken Sie vor Beginn dass Sie die seriellen Slave Adressen 1 bzw 16 nicht im automatischen bertragungsmodus in einer Ger tekette mit gemischten Protokollen benutzen d rfen beispielsweise bei einer Ger tekette mit Ger ten von denen einige das Powerlogic Protokoll und andere ein Modbus RTU Jbus Protokoll verwenden Anschluss von Ger ten an ein EGX Abbildung 8 und Abbildung 9 zeigen wie Ger te an das EGX angeschlossen werden k nnen Um diese Ger te zur Ger teliste hinzuzuf gen f hren Sie die unter Ger teliste einrichten auf Seite 13 beschriebenen Schritte aus Abbildung 8 Topologie nur serielle Slave Ger te Ethernet Verbindung EGX300 Webseiten Serielle Slave Ger te Abbildung 9
25. Seleccione Cada hora Diariamente Semanalmente Selecciona la frecuencia con la que Mensualmente o Intervalo de registro se transportan los registros de datos Dependiendo de las opciones seleccionadas en el Selecciona cu ndo se transportan paso anterior seleccione la hora del d a el d a de la los registros de datos semana y o el d a del mes En los cuadros de texto Direcci n IP del servidor Introduce la direcci n del servidor introduzca la direcci n del servidor FTP saliente que transporta los registros de 0 0 0 0 a 255 255 255 255 datos NOTA Pregunte al administrador de la red en caso de que usted no conozca la direcci n del servidor de protocolo de transferencia de archivos FTP En el cuadro de texto Puerto TCP del servidor Introduce el puerto de entrega introduzca el puerto del servidor FTP saliente Predeterminado 21 En el cuadro de texto Directorio introduzca el Le permite introducir informaci n directorio de directorio correspondiente al servidor remoto 9 Introduzca su nombre de usuario y contrase a en los Registra sus datos de inicio de cuadros de texto sesi n en el servidor 10 Habilite la casilla de verificaci n Pasivo Establece la transferencia pasiva de archivos por FTP 11 Haga clic en Probar FTP para probar los par metros Env a un archivo de prueba al del FTP o haga clic en Aplicar servidor y directorio FTP aplica los valores del FTP o realiza ambas NOTA Al hacer clic en Pro
26. login 2 user interface 3 e mail export device log 19 interval data log 44 error codes data log 43 Ethernet and TCP IP settings 5 Ethernet protocols 59 2011 Schneider Electric All Rights Reserved Ethernet settings advanced 6 executable binary component firmware version 57 exporting the device log 19 F file image component firmware version 57 firmware getting new 57 updating 58 updating via ftp 56 ftp export device log 21 using to add web pages 30 using to delete web pages 30 using to retrieve data log 43 H hardware 59 HTTP export device log 22 port number setup 7 retrieving interval data log 44 HTTPS port number setup 7 interval data log via data points button 44 via e mail 44 via ftp 43 via HTTP 44 via Microsoft Web Query 44 intervals logging 17 introduction 1 IP address detecting duplicate 8 L logging 17 40 data format 42 topics 18 logging in to EGX 2 logging intervals 17 maintenance log 56 audit trail 34 Microsoft Web Query interval data log 44 Modbus devices discovering 15 Modbus TCP IP filtering setup 25 monitoring 37 PowerLogic Ethernet Gateway EGX300 Index N network access via 2 network time synchronization setup 24 P password strength color indication 28 preferences customizing the EGX 32 R read device registers 54 real time data 37 remote device connections 10 S serial port settings advanced 9 serial port setup 8 setup d
27. tait exacte au moment de la publication de ce document Reportez vous au site www schneider electric com pour les mises jour Tableau 20 EGX300 Types d appareil pris en charge Groupe d appareils Appareils Filtre d harmoniques actif Accusine Disjoncteurs Compact NSX A Compact NSX E PowerPact A PowerPact E Circuit Monitors CM100 200 CM2000 CM3000 CM4000 ION7500 ION7550 ION7600 ION7650 Appareils de mesure logiques DM6000 DM6300 R gulateur de temp rature num rique Mod le 98 Variateurs ATV61 ATV71 Appareils de mesure d nergie Energy Meter Enercept E5600 EM1200 EM26 96 EM6400 EM6433 EM6436 EM6436DUAL EM6438 ION8600 Appareils de surveillance d isolement Vigilohm IM20 Vigilohm IM20 H Gestion de moteur TeSys T MCM Multi Circuit Monitors BCPM mod le A BCPM mod le B BCPM mod le C BCM MCM Relais de surcharge SSOLR MotorLogic Plus MotorLogic Plus II Contr leur de facteur de puissance Varlogic Power Meters PM9c PM200 PM300 PM500 PM600 PM700 PM800 PM1000 PM5000 ION6200 Standard et Mega ION7300 Relais de protection Sepam 2000 Sepam s rie 10 Sepam s rie 20 Sepam s rie 40 Sepam s rie 80 2011 Schneider Elec
28. 143 291 200 Reactive kVAR es a 136 Aparente kVA 18 278 22 Factor de potencia total 0 849 retardo 0 944 retardo 0 948 retardo Tensi n v12 479 484 4 v23 485 489 48 va 485 450 49 VLL medis 483 488 497 Vin 27 280 285 Van 278 281 226 Van 281 285 289 VUN media 279 282 287 Frecuencia Hz 59 94 80 01 80 08 Demanda intensidad A m 323 24 788 2008 08 10 12 58 30 2009 05 28 15 41 15 12 345 Y 782 2009 08 04 13 53 53 2009 05 28 15 41 15 13 331 22 801 2009 08 10 12 57 05 2009 05 28 15 41 15 Demanda potencia Activa kW 25 285 314 2010 02 11 13 30 48 2010 02 01 00 00 00 Resctivs KVAR 7 El 149 2010 02 03 14 37 37 2010 02 01 00 00 00 Aparente kVA 283 283 45 2010 02 03 14 37 37 2010 02 01 00 00 00 Energia Energ a activa kWh 2449677 4 2009 01 21 10 56 05 Energia resct kVARh 1167058 1 2009 01 21 10 58 05 Energis aperente k VAh 2722587 4 2003 01 21 10 58 05 O 2011 Schneider Electric Reservados todos los derechos 37 Pasarela Ethernet EGX300 de PowerLogic Supervisi n Rango de los indicadores anal gicos P ginas de resumen de dispositivos 38 63230 319 216B2 11 2011 Es posible configurar el rango de los indicadores gr ficos anal gicos de la pagina Lecturas b sicas o bien establecer que se ajuste autom ticamente Figura 31 En Activar escala autom tica marque los dispositivos en los que Habilita la escala desea que la escala de los indicadores se ajuste autom
29. 63230 319 216B2 indice 11 2011 Obtenci n de un registro de datos de intervalo mediante FTP 43 Obtenci n de un registro de datos de intervalo mediante el bot n Puntos de datos nenn 44 Obtenci n de un registro de datos de intervalo mediante la funci n de consulta Web de Microsoft 44 Obtenci n de un registro de datos de intervalo mediante COFPEO SIE CHOMICO EEE EEE ETE 44 Obtenci n de un registro de datos de intervalo mediante HTTP 44 P ginas de resumen de dispositivos 242240s00nennnnnnnnennnnnnnenn Panel de instrumentos saeir Visualizaci n de un panel de instrumentos Obtenci n de los datos del panel de instrumentos mediante el bot n Puntos de datos nono nencnnnns 48 Guardar un panel de instrumentos cceceeeeeeeeeeeesesesetsteeeeeaeeeees 48 Punto de acceso del sistema oooocccccnnnncccccccccccocccnccocanoncncnncnnnn nc cnc nnnnnn cnn 48 Documentaci 5 esse deidad 49 COMTI ON 522 Feats Er E Ried acd NE Bl re drain 49 Diagnosticos Estad sticas nennen Interpretaci n de las estad sticas nn nnnnennnnnnnenn Lectura de registros de dispositivo Comprobaci n de las comunicaciones Comprobaci n de comunicaciones automatizada 55 Comprobaci n de comunicaciones manual
30. Abrufen eines Intervalldatenprotokolls ber HTTP bersichtsger teseiten ooococcoononnnencnnenconenconenconenroncnnencnnonoo Instrumententafeln u oi pena Anzeigen einer Instrumententafel nenn Abrufen von Instrumententafeldaten mit der Schaltfl che Datenpunkte sise Speichern einer Instrumententafel Systemzugangspunkt uu nenn ana nenn Unterlagen 222 2 ehe 49 SteUCrUNd a a rar Toi tement etes nee 49 Diagnose erie aa ne eee ess da des Statistik Statistik auswerten Ger teregister lesen Kommunikationspr fung Automatische Kommunikationspr fung 55 Manuelle Kommunikationspr fung 242244400snn sn nnnnennnnnnnenn 55 Firmware 22 na en ene a eee diese des Firmwareversion feststellen cccccccecceeeeeeeeeeceeeeeeeeeeeeeeseneeaeeeeeeeanaeees Firmwareversion der ausf hrbaren Bin rkomponente Firmwareversion der Datei Image Komponente Neue Firmware herunterladen Firmware aktualisieren cccccccceeeeceecceececeeeceeeeeeeeeeeeeeeseseeaeeeeeeeeeaeeeees Anhang A Unterst tzte Ethernet Protokolle ccccsseseeeeeesereeeeees 59 Hardware 2 ir 59 Anhang B Unterst tzte Ger tetypen unnsnnssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 60 ii 2011 Schneider Electr
31. Alle Rechte vorbehalten 13 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Abbildung 11 Seite Ger teliste mit unterst tzten Fernverbindungen Ger teliste Anzahl anzuzeigende Ger te 8 Verbindung Ger tetyp Ger tebezeichnung Lokale ID Fern ID Building Main Building West Panel Building East Panel Building North Panel Serielle Schnittstelle EJ Modbus M Serielle Schnittstelle Modbus g Serielle Schnittstelle I Modbus M Serielle Schnittstelle i Modbus Erkennung bernehmen Tabelle 7 Ger telisteneinstellungen Anzahl Auswahl der Anzahl anzuzeigender Ger te 1 bis 64 anzuzeigende Werkeinstellung 8 Ger te Verbindung Auswahl des Verbindungsstandortes Serielle Schnittstelle oder IP Adresse Werkeinstellung Serielle Schnittstelle Ger tetyp Auswahl des Ger tetyps der in der Liste Bereich unterst tzter Ger te erscheinen soll Ger tebezeichnung Erm glicht die Bezeichnung einzelner Ger te Lokale ID Sie m ssen die Lokale ID festlegen 14 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Ger teerkennung 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Setup Mit der Option Ger teerkennung kann das EGX an der seriellen Schnittstelle angeschlossene Modbus Ger te erkennen die nicht in der Ger teliste enthalten s
32. Ethernet Il Media Type Used to define the physical Ethernet 10T 100Tx Auto connection or media type 10BaseT HD e 10BaseT FD e 100BaseTX HD e 100BaseTX FD Default 10T 100Tx Auto Obtain IP Address Used to automatically obtain an IP address Enabled or disabled Automatically from a BootP server Default Disabled NOTE Requires network administration support IP Address Used to enter the static IP address of the Default 169 254 0 10 EGX Subnet Mask Used to enter the Ethernet IP subnet mask Default 255 255 0 0 address of your network Default Gateway Used to enter the gateway router IP Default 0 0 0 0 address used for wide area sre WAN communications PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Advanced Ethernet Settings CAUTION IMPAIRED NETWORK PERFORMANCE Only qualified workers should modify the advanced Ethernet settings of the EGX Such modifications should be performed only after reading about and understanding the advanced Ethernet settings Failure to follow these instructions can impair network performance 1 Click Advanced on the Ethernet amp TCP IP Opens the Advanced Ethernet Settings page page 2 Configure the advanced Ethernet settings Sets up the advanced Ethernet settings see Table 3 on page 7 for available options Click Defaults to select the default values for all options 3 Click Apply Updates the EGX Ethernet and TCP IP settings
33. Le Point d acc s syst me ainsi cr permet d acc der aux appareils Schneider Electric mis en r seau La page Point d acc s syst me fournit un hyperlien vers chaque appareil Schneider Electric d tect Lorsque vous survolez un hyperlien avec la souris des informations suppl mentaires sur l appareil s affichent gauche de la liste Cliquez sur un appareil pour afficher la page de connexion cet appareil Figure 44 Page Point d acc s syst me avec d tails de l appareil Point d acc s syst me Plateforme EGX300 Adresse MAC 00 80 67 80 5B 63 Version de logiciel embarqu 4000 Numero de serie 23395 Temps de retenue 12 Nom de l quipement Adresse IP PowerLogic EGX300 169 254 0 20 PoweDpgic EGX300 169 254 0 30 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 DOCUMENTATION COMMANDE 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Documentation La page Documentation permet d acc der aux informations qui ont t stock es sous forme de fichiers sur la passerelle EGX et de liens Web Pour des informations sur le chargement de liens vers la documentation voir Liens vers la documentation page 26 Pour ouvrir un l ment de documentation cliquez sur le lien Documentation en haut de la page puis s lectionnez le lien qui vous int resse Figure 45 Page Documentation
34. NOTE Clicking Test applies the log export HTTP settings and transfers a test file Clicking Apply only applies the settings 22 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Date and Time 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup Figure 17 Device Log Export Page HTTP Device Log Export 486 271 Disabled E Mail C FTP HTTP Incremental I Logging Interval Hourly Daily Weekly Monthly Time of Day 00 00 Day of the Week Sunday Day of the Month LE Server IP Address bP o o o Server TCP Port 0 Path PF Field Name faatae Host Name A optional virtual host name Username fuser o Password jeeeeeeee SSL M Manual Export Test E Mail Test FTP Test HTTP Apply The Date and Time page allows you to set the date and time for the EGX 1 From the Setup menu click Date and Opens the Date and Time page Time 2 Configure the year month day hour Sets up the date and time minutes and seconds 3 Select the Time Zone Offset Sets the clock to the selected time zone 4 To set the clock to automatically adjust to Allows you to set the clock to adjust to Daylight Daylight Savings Time enable the Enable Savings Time automatically Automatic Daylight Savings Time Adjustment check box 5 Enter the number day month and hour to Sets
35. Pour chaque canal vous choisissez le ou les groupes de rapports qui pourront afficher les messages Lorsque vous s lectionnez un groupe de rapports pour un canal vous voyez s afficher les messages g n r s dans ce groupe de rapports Les canaux de messages sont les suivants e Fichier journal de maintenance interne de EGX e Serveur Syslog distant Syslog est un protocole pour les messages de journalisation e Courrier lectronique Tous les messages sont horodat s et identifient le groupe de rapports et l utilisateur 33 Passerelle Ethernet PowerLogic EGX300 Configuration 34 63230 319 216B2 11 2011 La page Piste d audit est divisee en trois sections correspondant aux trois canaux de messages Journal de maintenance Syslog Courrier electronique Voir Figure 28 page 35 Vous pouvez configurer s par ment les messages envoy s sur chaque canal Dans la fen tre Configuration cliquez sur Piste d audit La page Piste d audit s affiche Suivez les instructions du tableau ci dessous Tableau 14 Configuration de la piste d audit Journal de maintenance Contr le les types de Les messages g n r s apparaissent Cochez les options de rapport rapport pour lesquels dans le journal de maintenance que vous souhaitez inclure vous souhaitez voir interne de l EGX Par d faut aucune option appara tre des messages n est coch e dans le journal des Adresse IP du serveur Les messages g n r s so
36. Truncated Binary Exponential Backoff algorithm Frames Received OK A counter that increments each time a frame is successfully received CRC Errors A counter that increments each time a frame is received that has a checksum CRC that does not match what is calculated Alignment Errors A counter that increments each time a frame is received that has a checksum CRC error and does not end on an 8 bit frame boundary Frames Too Long A counter that increments each time a frame is received that is larger than the allowed maximum size defined in the standards frames larger than 1518 bytes Frames Too Short A counter that increments each time a frame is received that is smaller than the allowed minimum size defined in the standards frames smaller than 64 bytes Modbus TCP IP Server Frames Sent A counter that increments each time a frame is sent Frames Received A counter that increments each time a frame is received Protocol Errors A counter that increments each time an ill formed message is received Active Connections A status value that represents the number of connections that are active at the moment the diagnostics page is refreshed A maximum of 64 connections are supported Clicking Active Connections opens a new window with a list of all of the active client connections Accumulative Connections A counter that increments each time a connection is made to the EGX Maximum Connections A status value that repr
37. _1_ Gateway Name Gateway SN Gateway IP Address Gateway MAC Address Device Name Device Local ID Device Type ID Device Type Name Log Interval 2 EGX300 0 157 198 184 125 00 80 67 80 5B 61 Building Main 1 5 CM4000 5 3 4 Topic ID 1 Topic ID 2 Topic ID 3 5 1617 1621 1625 6 Bra Error UTC Offset Minutes Local Time Stamp Scheinenergie kVAh Wirkenergie kWh Blindenergie kVARh 8 0 360 02 12 2010 13 20 2 708 484 084 2 436 019 161 1 160 734 726 9 0 360 02 12 2010 13 25 2 708 509 192 2 436 042 802 1 160 743 040 10 0 360 02 12 2010 13 30 2 708 534 061 2 436 066 114 1 160 751 553 11 0 360 02 12 2010 13 35 2 708 559 927 2 436 090 052 1 160 761 238 12 0 360 02 12 2010 13 40 2 708 586 181 2 436 114 595 1 160 770 444 13 0 360 02 12 2010 13 45 2 708 612 190 2 436 138 843 1 160 779 716 14 0 360 02 2 2010 13 50 2 708 637 907 2 436 162 783 1 160 788 984 15 0 360 02 12 2010 13 55 2 708 663 298 2 436 186 450 1 160 798 048 Fehlercodes f r Datenprotokolle Die nachstehenden Fehlercodes sind u U bei der Fehlerbehebung von Datenprotokollen zu sehen siehe Abbildung 36 auf Seite 41 und Abbildung 37 auf Seite 41 Fanar Definition code Ein Kommunikationsfehler ist aufgetreten z B Die Aufzeichnung bleibt CRC Fehler Protokollfehler oder Ausnahme eingeschaltet sofern das letzte Intervall nicht fehlt Zeit berschreitung nach Sendung einer Anfrage Die Aufzeichnung bleibt wurde innerhalb der zul ssigen Zeit keine eingeschaltet sofern da
38. appareils distants L EGX peut tablir des connexions pour un maximum de 16 appareils Modbus TCP IP distants uniques d finis par l utilisateur Vous pouvez entrer les connexions manuellement ou les s lectionner dans le tableau des connexions d tect es par le Point d acc s syst me voir Figure 7 Ces connexions seront ajout es a la configuration de la liste des appareils pour la configuration d appareils distants 1 Dans le menu Configuration cliquez sur Ouvre la page Connexions d appareils distants Connexions d appareils distants 2 Pour ajouter manuellement une connexion Configure les adresses IP des appareils entrez les adresses IP des appareils distants distants auxquels vous souhaitez vous connecter 3 Pour ajouter une connexion d tect e par le Entre l adresse IP de la connexion s lectionn e Point d acc s systeme cliquez sur Ajouter parmi les connexions d tect es par le Point droite de la connexion souhait e dans le d acc s syst me tableau des connexions d tect es 4 Cliquez sur Appliquer Met jour les param tres de connexions d appareils distants de la passerelle EGX 10 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 2011 Schneider Electric Tous droits r serv s Figure 7 Connexions d appareils distants Passerelle Ethernet PowerLogic EGX300 Configuration Connexions d appareils distants
39. auf O kann ein EGX300 alle EGX300 Ger te mit derselben Gruppen IP Adresse ohne Ber cksichtigung der Gemeinschaftsein stellung erkennen Werkeinstellung 0 9 Standardwerte bernehmen Klicken Sie auf bernehmen um Ihre Eintr ge zu speichern bzw auf Standardwerte um zu den aufgelisteten Werkeinstellungen zur ckzukehren Abbildung 29 Setup Seite f r den Systemzugangspunkt Systemzugangspunkt Aktiviert UDP Port 59 1 65535 Gruppen IP Adresse 224 0 1 2 Meldungsintervall 300 1 65535 Sekunden Haltezeit 600 2 65535 Sekunden Multicast G ltigkeitsdauer 4 1 255 Hops Gemeinschaft 0 0 65535 Standardwerte bernehmen 36 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 BERWACHUNG Echtzeitdaten Einzelger teseiten Grundmesswerteinstellungen PowerLogic Ethernet Gateway EGX300 berwachung Das EGX bietet Bildschirmanzeigen f r die Anzeige von Echtzeitdaten und Trendkurven zusammen mit historischen Datenprotokoll Trendkurven Die Seite Echtzeitdaten stellt grundlegende Messwerte ausgew hlter Ger te in Echtzeit sowie Ger te bersichten bereit Um eine Tabelle mit Echtzeitdaten zu betrachten wechseln Sie in das berwachungsmen und w hlen Sie ein Ger t unter Echtzeitdaten gt Einzelger teseiten aus W hlen Sie oben auf der Anzeige entweder Laststrom Leistung L L Spannung oder L
40. dans la liste des appareils Par d faut Activ Connexion Affiche la connexion sur laquelle l appareil Port s rie ou adresse IP pour a t d tect ou valid la validation des appareils distants Defini Affiche le type d appareil d fini pour cet appareil Attribu Permet de s lectionner le type d appareil dans la liste d roulante Nom Permet de personnaliser le nom de l appareil Identification Affiche l identification locale locale Identification Affiche l identification distante distante tat Affiche l tat de la d tection ou de la Valide Inconnu chec validation D tect D tection ou Essai 16 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Journaux d appareil Enregistrement des donn es par intervalle Configuration de l intervalle d enregistrement 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Configuration L enregistrement des journaux est disponible pour tous les types d appareils pris en charge par la passerelle EGX La passerelle EGX peut enregistrer dans un journal des intervalles pr d finis 5 10 15 20 30 et 60 minutes les donn es transmises par des appareils connect s localement et distance Cette section d crit comment la passerelle EGX enregistre les donn es dans les journaux et comment configurer l enregistrement des journaux pour un appareil Dans un syst me de surveill
41. fo 0 0 0 Server UDP Port 514 1 65535 Facility Severity Report I System Error Localo 16 errors 8 F Security Error Anna warnings F Configuration Local 16 Notifications I Informational Local 16 Informational u A From Address To Addresses Server IP Address bp fp po po Server TCP Port 25 1 65535 SMTP server requires login Username Password Report 7 System Error FT Security Error I Configuration I Informational Defaults Apply The system access point provides a means of discovering and linking to other Schneider Electric devices connected to the network This feature is configured to run by default with no need for additional configuration Use this setup screen to enter the group IP address and related information 1 From the Setup menu click System Opens the System Access Point window Access Point 2 Enabled When checked EGX300s with the same Group IP Addresses will be able to discover each other Default Enabled 3 UDP Port Type the port number from 1 65535 for the UDP port used by the System Access Point discovery Default 59 4 Group IP Address Type the group IP address which will support multicast or unicast addresses Default 224 0 1 2 5 Hello Time This is the period of time between Hello messages emitted by this EGX300 announcing its presence to other Schneider Electric System Access devices on the n
42. nergie radiofr quence et s il n est pas install ou utilis conform ment au mode d emploi il peut provoquer des interf rences nuisibles aux communications radio Le fonctionnement de cet appareil dans une zone r sidentielle est susceptible de provoquer des interf rences nuisibles auquel cas l utilisateur devra corriger les interf rences ses propres frais Cet appareil num rique appartient la Classe A et est conforme la norme ICES 003 du Canada 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Table des matieres Table des matieres Table des matieres uunsnsnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnn i Introduction a e era a aa aan Ea aa aaa a aK Aara aa S EnaA s dana anian Sanaa RENEK anian 1 Ressources suppl mentaires nennen 1 Acc s la passerelle EGX via un r seau Connexion la passerelle EGX unennsesnseneeennnnnnnnnnn nme nennen nennen nenn nn Presentation de l interface utilisateur EGX unnesnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 3 Configuration nnurresnnnennnnnnnnnnnnnnennnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnsnnnnnnn nennen Param tres Ethernet et TCP IP Param tres Ethernet avanc s D tection des adresses IP identiques oooconinicccccnnncococcccccccnancnccnnnnnnos 8 POTESONO Lande a 8 Param tres avanc s du port s rie 9 Connexions d appareils distants e cccceeeeeeeeeeeeeeeeeeaeeeeeeseaeeeeeeeeeaaes 10 Liste
43. pertoire de documentation est vide a cd http ica http www PowerLogic com PowerLogic com ic http www Schneider Electric com Schneider Electric com REMARQUE Pour des informations sur la documentation charg e voir Documentation page 49 27 Passerelle Ethernet PowerLogic EGX300 Configuration Comptes utilisateur 28 63230 319 216B2 11 2011 Les utilisateurs de la passerelle EGX re oivent un nom d utilisateur et un mot de passe Chaque utilisateur appartient un groupe et chaque groupe a des droits d acc s aux pages Web EGX qui lui sont attribu s par l administrateur EGX REMARQUE Il existe deux comptes utilisateur par d faut Administrator administrateur mot de passe Gateway et Guest invit mot de passe Guest 1 Dans le menu Configuration cliquez sur Comptes Ouvre la page Comptes utilisateur utilisateur 2 Si vous voulez modifier le nom d un groupe tapez le Entrez le nom du nouveau groupe nouveau nom dans l une des zones de texte de la zone Groupes vous ne pouvez pas modifier le nom du groupe Administrator 3 Dans la zone Utilisateurs saisissez le nom 1 24 Definit le nom et le mot de passe caract res et le mot de passe 0 12 caract res du d un utilisateur nouvel utilisateur L EGX300 indique par une couleur REMARQUE Les noms et les mots de passe des et une mention textuelle le niveau utilisateurs distinguent les majuscules et
44. r die Geben Sie die TCP Port Server IP Adresse Nummer ein Die Werkeinstellung lautet 25 SMTP Server Aktivieren Sie dieses Kontrollk stchen Markieren Sie das erfordert um die Anmeldung f r den Empfang von Kontrollk stchen um mit dem Anmeldung E Mails zu aktivieren Der SMTP Server Hinzuf gen von Anmeldedaten erfordert eine Anmeldung zu beginnen Benutzername Das ist der Benutzername den das EGX Geben Sie den f r den SMTP verwendet um sich beim SMTP Server Server erforderlichen Benutzer anzumelden namen ein max 31 Zeichen Kennwort Das ist das Kennwort welches vom EGX Geben Sie das f r den SMTP verwendet wird um sich beim SMTP Server erforderliche Kennwort Server anzumelden ein max 31 Zeichen Bericht Das sind die Berichtstypen f r die Aktivieren Sie die Meldungen weitergeleitet werden k nnen Berichtstypen f r die Sie Sie k nnen beliebig viele ausw hlen Meldungen haben m chten Standardwerte Klicken Sie auf bernehmen um die von Klicken Sie auf bernehmen bernehmen Ihnen vorgenommenen Eintr ge zu oder auf Standardwerte speichern Klicken Sie auf Standardwerte um jedes Feld auf seine Werkeinstellung zur ckzusetzen 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Setup Abbildung 28 Pr fpfadeinrichtung Pr fpfad Wartungsprotokoll Bericht Systemfehler Sicherheitsfehler Konfigu
45. seau qui permet de transf rer des fichiers d un ordinateur a un autre sur Internet Les modes FTP actif et passif sont pris en charge principalement via le port TCP 21 Simple Network Management Protocol SNMP Bas sur le format MIB2 SNMP permet d enregistrer et d identifier des informations de diagnostic utilis es pour la gestion du r seau via le port UDP 161 ARP Address Resolution Protocol ARP convertit des adresses IP en adresses Ethernet La passerelle EGX envoie des requ tes ARP pour verifier si son adresse IP est d ja utilis e voir Detection des adresses IP identiques page 8 Simple Network Time Protocol SNTP Le protocole SNTP permet de synchroniser les horloges des appareils en r seau l aide d un serveur SNTP via le port UDP 123 Port Ethernet RJ 45 Alimentation Voyant LED pour les communications Ethernet et s rie RS485 PowerLog Voyant LED d alimentation et d etat Bouton de ER r initialisation Port serie RS 232 Port serie RS 485 Cavaliers de polarite de terminaison et 2 4 fils connecteur RJ 45 2011 Schneider Electric Tous droits r serv s 59 Passerelle Ethernet PowerLogic EGX300 Annexe B Types d appareil pris en charge ANNEXE B TYPES D APPAREIL PRIS EN CHARGE 60 63230 319 216B2 11 2011 La passerelle EGX prend en charge les types d appareil suivants La liste des appareils pris en charge
46. tetypen aus die f r die Konfiguration Auswahl von Ger tetypen die f r der Ger teliste verf gbar sein sollen die Konfiguration der Ger teliste HINWEIS Klicken Sie auf Alle ausw hlen um alle verf gbar sein sollen Ger te zu aktivieren bzw auf L schen um alle Ger te zu deaktivieren HINWEIS Die Verf gbarkeit des Ger tetyps kann bei gerade verwendeten Ger ten nicht ge ndert werden 3 Klicken Sie auf bernehmen Speichern der Einstellungen f r Anzeigbare Ger tetypen Abbildung 27 Seite Anzeigbare Ger tetypen Anzeigbare Ger tetypen ATS48 ATV61 M ATV71 M Accusine M BCM M BCPM Model A M BCPM Model B M Model C Der Pr fpfad besteht aus einer Folge von Aufzeichnungen oder Meldungen mit Zeitstempel Er zeichnet Konfigurations nderungen Fehler und fehlgeschlagene Authentifizierungen auf Au erdem identifiziert er den Benutzer der das Ereignis ausgel st hat Verwenden Sie die Seite Pr fpfad um die vier Berichtsgruppen und die Meldungskan le einzurichten F r jeden Kanal sind die Berichtsgruppen auszuw hlen f r die Meldungen angezeigt werden sollen Wenn Sie eine Berichtsgruppe f r einen Kanal ausw hlen sehen Sie alle Meldungen die in dieser Berichtsgruppe generiert werden Folgende Meldungskan le stehen zur Verf gung Onboard Wartungsprotokolldatei f r das EGX Entfernter Syslog Server Syslog ist ein Standard f r die Protokollierung vo
47. trama que excede el tama o m ximo definido en las normas tramas de m s de 1518 bytes Tramas demasiado cortas Contador que aumenta cada vez que se recibe una trama que no alcanza el tama o m nimo definido en las normas tramas de menos de 64 bytes Modbus TCP IP Servidor Tramas enviadas Contador que aumenta cada vez que se envia una trama Tramas recibidas Contador que aumenta cada vez que se recibe una trama Errores de protocolo Contador que aumenta cada vez que se recibe un mensaje mal formado Conexiones activas Valor de estado que representa el numero de conexiones activas en el momento de actualizaci n de la p gina de diagn sticos Se admite un m ximo de 64 conexiones Al hacer clic en Conexiones activas se abre una ventana nueva con una lista de todas las conexiones clientes activas Conexiones acumuladas Contador que aumenta cada vez que se realiza una conexi n a la EGX Maximo de conexiones Valor de estado que representa el n mero maximo de conexiones que pueden estar activas en un momento dado Mensajes entrantes de lectura Contador que aumenta cada vez que se recibe un mensaje de solicitud de lectura Mensajes entrantes de escritura Contador que aumenta cada vez que se recibe un mensaje de solicitud de escritura Mensajes salientes de respuesta Contador que aumenta cada vez que se envia un mensaje de respuesta Tramas enviadas Contador que aumenta cada vez que se envia una trama Tramas reci
48. 12 2010 13 35 2708559 927 2436090 052 1160761 238 12 0 360 02 12 2010 13 40 2708586 181 2436114 595 1160770 444 13 D 360 02 12 2010 13 45 2708612 19 2436138 843 1160779 716 14 0 360 02 12 2010 13 50 2708637 907 2436162 783 1160788 984 15 0 360 02 12 2010 13 55 270863 298 2436186 45 1160798 048 C digos de error para los registros Al resolver problemas en los registros cronol gicos de datos nos cronol gicos de datos encontraremos con los c digos de error que aparecen a continuaci n consulte la Figura 36 de la p gina 41 y la Figura 37 de la p gina 41 C digo Definici n Resultado de error Ha ocurrido un error de comunicaciones por Se deja habilitado el registro a ejemplo CRC protocolo o excepci n menos que se haya perdido el ltimo intervalo El tiempo de espera se produjo cuando se envi una Se deja habilitado el registro a solicitud sin recibir la respuesta correspondiente menos que se haya perdido el durante el tiempo permitido ltimo intervalo 100 Intervalo de tiempo transcurrido antes de que se Intervalo perdido pudieran registrar los datos P ngase en contacto con el soporte t cnico si necesita ayuda para resolver estas u otras condiciones de error Obtenci n de un registro de datos de Puede utilizar FTP para recuperar un archivo de registro de datos intervalo mediante FTP conect ndose a la EGX a trav s de FTP y transfiriendo el archivo csv como se indica en los pasos siguientes NOTA Si desea que la EGX
49. 169 254 0 10 en el cuadro de texto Direcci n y luego pulse Intro 2 Escriba el nombre de usuario Administrator Abre una sesi n de FTP con la EGX y la contrasefia de administrador en los cuadros de texto y luego haga clic en Iniciar sesi n 3 Abra la carpeta que contiene la pagina web Abre la carpeta que contiene la p gina web personalizada haga clic con el bot n personalizada y despu s borra el archivo derecho del rat n sobre el archivo que quiera eliminar y despu s haga clic en Eliminar 4 Haga clic en Cerrar en la ventana del Cierra el Explorador de Windows Explorador de Windows O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuracion Agregar o quitar paginas web a o de la 1 Enel ment Configuraci n haga clic en Abre la pagina Acceso a pagina Web Acceso a pagina Web 2 Haga clic en Agregar o quitar paginas Abre la pagina Agregar o quitar paginas Web Web consulte la Figura 25 3 Si ha agregado p ginas web Selecciona una pagina web personalizada o personalizadas a cualquiera de las anula la selecci n de esta carpetas de la EGX ver una lista de los nombres de archivo debajo del nombre de cada carpeta Seleccione las p ginas web que desee que vean los usuarios Anule la selecci n de las p ginas web que no desee que vean los usuarios NOTA Al anular la selecci n de una p gina web esta no se borra de la EG
50. 44 Microsoft Web Query 44 Schaltfl che Datenpunkte 44 Intervalle Aufzeichnung 17 IP Adresse Erkennung identischer Adressen 8 K Kennwortsicherheit Farbcode 28 Kommunikationspr fung 55 Automatisch 55 Manuell 55 L Lesen Ger teregister 54 Microsoft Web Query Intervalldatenprotokoll 44 Modbus Ger te Erkennung 15 Modbus TCP IP Filter Einrichten 25 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Index N Netzwerk Zugang Uber 2 Netzwerkzeitsynchronisation Einrichten 24 P Pr ferenzen Anpassen des EGX 32 Pr fpfad 33 Syslog Feld 34 Wartungsprotokoll 34 Pr fung 50 S Schaltfl che Datenpunkte Intervalldatenprotokoll 44 Serielle Schnittstelle einrichten 8 SNMP Parameter Einrichten 25 Statistik 50 Auswerten 51 Steuerung 49 Syslog Pr fpfade 34 Systemzugangspunkt Einrichten 35 Links zu anderen EGX300 Ger ten 48 T TCP IP Einstellungen 5 Trendverfolgung 39 U bersichtsger teseiten 38 45 berwachung 37 Unterlagenlinks Einrichten 26 Unterlagenseite 49 Unterst tzte Ethernet Protokolle 59 Unterst tzte Ger tetypen 60 V Verbindungen zu entfernten Ger ten 10 Vertrauensw rdiges Zertifikat HTTPS Port Nr 7 W Wartungsprotokoll 56 Pr fpfad 34 Webseiten Einrichten 29 Benutzerdefiniert 30 Hinzuf gen zur Entfernen aus Webschnittstelle 31 Z Zeitsynchronisation Netzwerk 24 Zugang zum EGX ber ein Netzwerk
51. 5 Wiederholen Sie die Schritte 3 und 4 um Hinzuf gen weiterer IP Adressen f r den Filter weitere IP Adressen hinzuzuf gen 6 Klicken Sie auf bernehmen Speicherung der Modbus TCP IP Adressen Filterliste Abbildung 21 Seite Modbus TCP IP Filter Modbus TCP IP Filter Filter aktivieren IP Adresse Zugriffsberechtigung Das EGX unterst tzt zwei Arten von Unterlagenlinks 1 Zugriff auf lokale Dateien im EGX gespeicherte Onboard Unterlagen 2 Zugriff auf externe URLs HINWEIS Lokale Dateiunterlagen die auf der Unterlagenwebseite erscheinen sollen m ssen mit FTP in den EGX Ordner www documentation Unterlagen bertragen werden 1 Klicken Sie im Setup Men auf Einblendung der Seite Unterlagenlinks Unterlagenlinks 2 F r Dateizugriff Aktivieren Sie das Aktivierung der Dateien und URLs die auf der Kontrollk stchen Aktiviert f r die Unterlagenseite erscheinen sollen Dateinamenlinks die Sie aktivieren m chten F r URL Zugriff Aktivieren Sie das Kontrollk stchen Aktiviert f r die URL Links die Sie aktivieren m chten 3 Aktivieren Sie das Kontrollk stchen Neues Aktivierung derjenigen Dateien und URLs die Fenster wenn die ausgew hlten Dateien nach dem Anklicken in einem neuen Fenster und URLs nach dem Anklicken in einem angezeigt werden sollen neuen Fenster angezeigt werden sollen 4 Geben Sie in das Textfeld Link Text einen
52. Allows you to select the default homepage Home Circuit Summary Load Current Summary Demand Current Summary Power Summary or Energy Summary Default Home Real Time Sample Rate Controls how often data is read from the 5 to 60 seconds device s in the standard Monitoring Table views Communications Check Controls how often a communications Rate check is performed while the browser is displaying real time readings in the standard Monitoring Table views This function will attempt to automatically bring any out of service devices back into service Default 5 seconds Disabled 5 to 30 minutes Default 15 minutes 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Viewable Device Types Audit Trail 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup The Viewable Device Types page provides a means of managing the device types available for user selection in the Device List Setup web page Because the EGX300 supports many different device types removing device types from the list of Available Device Types may simplify configuration of the Device List Setup web page 1 From the Setup menu click Viewable Opens the Viewable Device Types page Device Types 2 Select the device types to make available Selects device types to be made available for for the device list configuration device list configuration NOTE Click Select Allto e
53. CSV Data points button HTML E mail CSV HTTP CSV Microsoft WebQuery HTML To view a list of all available log files follow steps 2 through 4 in the section Getting an Interval Data Log using FTP on page 43 Files will be in the format Device Name _ Local ID csv where Device Name is the name given to the slave device and Local ID is the numerical Local ID assigned to it For example a device named Building 1 Utility Entrance with a Local ID of 3 would be Building 1 Utility Entrance_3 csv When log files are exported the date and time are appended to the file name in the following format YYYYMMDDHHMMSS For example Building 1 Utility Entrance_3_20100218115216 csv This indicates that the file was exported on 2010 February 18 at 11 52 16 AM Data is logged in the following format see Figure 38 on page 43 Table 16 Interval data log format 1 BOM Gateway Name Gateway This row contains the column headings SN Gateway Address Device Name Device for the information in row 2 Local ID Device Type Name Logging Interval NOTE BOM The first three bytes of the file will be a 3 character Byte Order Mark indicating UTF 8 2 EGX300SD 23227 157 198 184 116 Building This row contains the information about 1 Utility Entrance 3 CM4000 15 the EGX and the logged device 4 Topic ID 1 Topic ID 2 Topic ID 3 This row contains the column headings for the topic IDs in r
54. Configuraci n 3 Activado intervalos 57024 dias 594 Intervalo de registro 15 minutos Esta opci n le permite exportar registros de dispositivos de tres maneras por correo electr nico por FTP o por HTTP En las secciones siguientes se describen dichos m todos NOTA Si los servidores de correo electr nico FTP o HTTP no est n situados en el mismo segmento de red Ethernet que la EGX aseg rese de configurar correctamente la pasarela predeterminada de la EGX Consulte Configuraci n de Ethernet y TCP IP en la p gina 5 1 O 2011 Schneider Electric Reservados todos los derechos En la p gina Configuraci n haga clic en Exportaci n del registro de dispositivos Seleccione Correo electr nico como modo de transporte Marque la casilla de verificaci n Incremental NOTA Si el transporte se programa como Cada hora o como Intervalo de registro la casilla de verificaci n Incremental se seleccionar autom ticamente NOTA Si no se selecciona la casilla de verificaci n Incremental se enviar el archivo de registros completo por correo electr nico en cada intervalo programado Seleccione Cada hora Diariamente Semanalmente Mensualmente o Intervalo de registro Abre la p gina Exportaci n del registro de dispositivos Abre las opciones de exportaci n de registros de dispositivos por correo electr nico Selecciona s lo datos de intervalos nuevos registrados desde la l
55. Copie le fichier de mise jour dans le Presse papiers Copie le fichier sur la passerelle EGX qui red marre V rifie la mise jour du logiciel embarqu 8 Cliquez sur le bouton Fermer de la fen tre Ferme Explorateur Windows et met fin la de l Explorateur Windows connexion FTP avec la passerelle EGX 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 ANNEXE A PROTOCOLES ETHERNET PRIS EN CHARGE Materiel Passerelle Ethernet PowerLogic EGX300 Annexe A Protocoles Ethernet pris en charge La passerelle EGX prend en charge les protocoles Ethernet suivants Modbus TCP IP Modbus TCP IP est une combinaison du protocole Modbus qui permet les communications ma tre esclave entre des appareils et de TCP IP qui permet de communiquer par le biais d une connexion Ethernet Modbus TCP IP permet d changer des donn es entre la passerelle EGX et d autres appareils compatibles Modbus TCP IP via le port TCP 502 Hypertext Transfer Protocol HTTP HTTP est un protocole r seau qui g re la remise de fichiers et de donn es sur le Web La fonctionnalit de service Web est assur e via le port TCP 80 HTTP s curis HTTPS HTTPS est un protocole r seau qui g re le transfert crypt de fichiers et de donn es sur le Web via la technologie SSL La fonctionnalit de service Web s curis est assur e via le port TCP 443 File Transfer Protocol FTP FTP est un protocole r
56. Diagnostics cliquez sur Ouvre la page V rification des V rification des communications communications Cliquez sur V rification de l tat des Effectue une v rification des communications appareils Pour les appareils communicants les valeurs R ussite et En service s affichent dans les colonnes Communications et tat respectivement Pour les appareils qui ne communiquent pas ces colonnes indiquent respectivement chec et Hors service si l chec se reproduit plusieurs fois Figure 49 Page V rification des communications V rification des communications areil Type d appareil Connexion Communications Etat Building East Panel CM4000 157198184114 R ussite En service Building Main CM4000 Port s rie R ussite En service Building WWest Panel PM6 modbus Port s rie R ussite En service V rifier l tat des appareils 55 Passerelle Ethernet PowerLogic EGX300 Maintenance MAINTENANCE LOGICIEL EMBARQUE FIRMWARE Recherche de la version du logiciel embarque 56 63230 319 216B2 11 2011 Le journal de maintenance permet de consigner les op rations de maintenance effectu es sur la passerelle EGX les quipements qui y sont connect s ou le syst me dont elle fait partie Chaque entr e est enregistr e avec la date et l heure de consignation ainsi que le nom de l utilisateur qui l a r alis e Ce journal indique galement l activit syst me par exemple les activations et
57. EGX300 11 2011 Monitoring MONITORING The EGX provides screen displays to view real time data and trends along with historical data log trends Real Time Data The Real Time Data pages provide basic readings of selected devices in real time as well as device summaries Single Device Pages To view a table of real time data go to the Monitoring menu and select a device under Real Time Data gt Single Device Pages Basic Readings Settings Power Voltage LL or Voltage LN to be displayed Jon the Analog Gauge graphic display on the Analog Gauge graphic display NOTE Analog gauges are not available for all device types By default the gauges will automatically adjust their Controls the display range of the display range For a fixed range select Range Analog Gauges Instructions for configuring the analog gauge range are listed in the next table Figure 30 Basic Readings Page Basic Readings Building Main CM4000 2010 02 15 12 40 50 o 330 la A 354 Ib A 342 Ic A Load Current A la 185 330 290 lb 186 2 296 Ic 188 342 281 LAvg 198 342 289 In o 2 3 la m Power Real kW 143 zm 200 Reactive kVAR 101 135 Apparent kVA 158 289 229 Power Factor Total 0 849 lag 0 897 lag 0 948 lag Voltage Vab 479 484 43 voc 485 439 498 Vca 485 490 42 LL Avg 482 488 497 Van ar 280 285 Von 278 20 236 Ven 281 284 289 VAN Avg zs 282 287 Frequency Hz 59 94 80 02 0 08 Demand Current A la 223 325 7
58. EM6400 EM6433 EM6436 EM6436DUAL EM6438 ION8600 Dispositivos de supervisi n de aislamiento Vigilohm IM20 Vigilohm IM20 H Administraci n de motores TeSys T Multi Circuit Monitors BCPM tipo A BCPM tipo B BCPM tipo C BCM MCM Rel s de sobrecarga SSOLR MotorLogic Plus MotorLogic Plus II Controlador de factor de potencia Varlogic Centrales de medida PM9c PM200 PM300 PM500 PM600 PM700 PM800 PM1000 PM5000 ION6200 Standard y Mega 2011 Schneider Electric Reservados todos los derechos ION7300 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Ap ndice B Tipos de dispositivos admitidos Tabla 20 Tipos de dispositivos admitidos por la EGX300 Grupo de dispositivos Dispositivos Rel s protectores Sepam 2000 Sepam Serie 10 Sepam Serie 20 Sepam Serie 40 Sepam Serie 80 Modulos de interfaz inteligentes SIM10Z SIM10M SIM6BZ Arranques suaves ATS48 MVSS RVSS Sensores de ZED THL M temperatura humedad luz Unidades de control Micrologic A Micrologic E Micrologic H Micrologic P Otros Acti9 Multicontrol 2011 Schneider Electric Reservados todos los derechos 61 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Ap ndice B Tipos de dispositivos admitidos 11 2011 62 2011 Schneider Electric
59. Erreur de connexion Compteur qui augmente d une unit chaque fois que la passerelle EGX ne parvient pas tablir la connexion avec le serveur SMTP Erreur d authentification Compteur qui augmente d une unit chaque fois que le serveur SMTP ne parvient pas authentifier les identifiants Utilisateur Mot de passe Envoi erreur Compteur qui augmente d une unit chaque fois qu un courrier lectronique ne peut pas tre envoy au serveur SMTP Erreur g n rale Compteur qui augmente d une unit chaque fois qu un courrier lectronique ne peut tre envoy parce que la passerelle EGX ne parvient pas cr er le message Syst me de fichiers Espace total Espace disque total de l EGX en kilo octets Espace libre Volume total d espace libre sur le disque de l EGX en kilo octets O 2011 Schneider Electric Tous droits r serv s 53 Passerelle Ethernet PowerLogic EGX300 Diagnostics Lecture de registres d appareils 54 63230 319 216B2 11 2011 Cette option permet la passerelle EGX de lire les donn es en provenance de appareils locaux ou distants qui lui sont connect s Figure 48 Page Lecture de registres d appareils Lecture de registres d appareils Nom d appareil Identification locale Registre de d part Nombre de registres S lection par ID de l appareil ml 1 1000 10 Registre Valeur Type de donn es Registres de maintien v D cimal O Hexad cimal O Binaire
60. Errors 0 2 Protocol Errors o ag 5 Sns 2 u Exceptions Received 0 Exceptions Received 0 RIN a en Ele ee en i Outbound Write Messages 0 Inbound Read Messages 0 rs a Inbound Write Messages 0 LS Details AAN AA es rene Frames Received 917 Firmware Version 3 740 Active Connections 4 er _ 87 80 5B 61 Accumulative Connections 316 Serial Number 0 Maximum Connections 6 Model Number EGX300 Hardware Version HTTP Client Manufacture Date 2006 01 01 Send OK 0 Connect Error 0 e URL Error 0 Send OK 0 8 Send Error o Connect Error o General Error 9 Authentication Error 0 Directory Error 0 Send Error o STP Cent General Error 0 Send OK 0 Connect Error 0 A du E Send Error 0 an ed General Error o Free space 243918 KBytes 99 50 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Interpreting Statistics 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Diagnostics OC See eed Link Status A status string that represents the speed and duplex setting being used to communicate with the linking partner Frames Transmitted OK A counter that increments each time a frame is successfully transmitted Collisions A counter that increments each time a frame is retransmitted due to collision detection Excessive Collisions A counter that increments each time a frame is not able to be sent due to reaching the maximum collision status based on the
61. Figura 42 Gr fico del panel de instrumentos PM5350 ID32 Energ a activa kWh Dia actual con dia anterior por horas Puntos de datos Dia actual Figura 43 Tabla del panel de instrumentos PM5350 ID32 Energ a activa kWh D a actual con d a anterior por horas Gr fico Mon Nov 28 00 00 00 CST 2011 Mon Nov 28 01 00 00 CST 2011 Mon Nov 28 01 00 00 CST 2011 Mon Nov 28 02 00 00 CST 2011 Mon Nov 28 02 00 00 CST 2011 Mon Nov 28 03 00 00 CST 2011 Mon Nov 28 03 00 00 CST 2011 Mon Nov 28 04 00 00 CST 2011 Mon Nov 28 04 00 00 CST 2011 Mon Nov 28 05 00 00 CST 2011 Mon Nov 28 05 00 00 CST 2011 Mon Nov 28 06 00 00 CST 2011 Mon Nov 28 06 00 00 CST 2011 Mon Nov 28 07 00 00 CST 2011 O 2011 Schneider Electric Reservados todos los derechos 47 Pasarela Ethernet EGX300 de PowerLogic Supervisi n Obtenci n de los datos del panel de instrumentos mediante el bot n Puntos de datos Guardar un panel de instrumentos Punto de acceso del sistema 48 63230 319 216B2 11 2011 Los datos de un panel de instrumentos se pueden guardar en una aplicaci n de hoja de datos tal como se muestra en los pasos que se indican a continuaci n Acci n Resultado 1 Enel panel de instrumentos que contiene Muestra los puntos de datos del panel de los datos deseados haga clic en Puntos instrumentos deseado Figura 43 de datos Pulse CTRL A y luego pulse CTRL C Selecciona todos los datos y luego los
62. Firmwareversion feststellen auf Seite 56 aus Einblendung des Dialogfelds Anmelden als Er ffnung einer FTP Sitzung mit dem EGX Kopieren der Firmware Datei in die Zwischenablage Kopieren der Firmware auf das EGX und Neustart des EGX HINWEIS Die LED Spannungsversorgung Status blinkt schnell w hrend die Datei auf das EGX bertragen und programmiert wird Nach Beendigung der Programmierung wird das EGX zur ckgestellt Die Programmierung dauert zwischen 1 5 und 2 Minuten Kopiert die Aktualisierungsdatei in die Zwischenablage Kopieren der Datei in das EGX und Neustart des EGX berpr fung der aktualisierten Firmwareversion 8 Klicken Sie im Windows Explorer Fenster Schlie en von Windows Explorer und Beenden auf Schlie en der FTP Verbindung zum EGX 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 ANHANG A UNTERST TZTE ETHERNET PROTOKOLLE Hardware PowerLogic Ethernet Gateway EGX300 Anhang A Unterst tzte Ethernet Protokolle Das EGX unterst tzt folgende Ethernet Protokolle Modbus TCP IP Modbus TCP IP ist eine Kombination aus dem Modbus Protokoll das die Master Slave Kommunikation zwischen Ger ten erm glicht und TCP IP das f r die Kommunikation ber eine Ethernet Verbindung sorgt Modbus TCP IP wird f r den Datenaustausch zwischen dem EGX und anderen kompatiblen Modbus TCP IP Ger ten ber TCP Port 502 verwendet Hypertext Transfe
63. IP HTTPS Port Nr Der f r HTTPS Meldungen verwendete TCP Port 1 bis 65 000 Das EGX wird mit einem selbstsignierten Werkeinstellung 443 Zertifikat ausgeliefert Damit aus dem EGX ein 0 HTTPS Port vertrauensw rdiger Server wird m ssen Sie ein deaktiviert Zertifikat von einer Zertifizierungsstelle erwerben z B VeriSign Authentication Services Um ein digitales Zertifikat hinzuzuf gen bzw zu installieren rufen Sie manuell mit der URL http x x x x update_certs_shtml wobei x x x x f r die IP Adresse des EGX steht die Zertifikataktualisierungsseite auf Max Anzahl der Legt die maximale Anzahl der HTTP Keep Alive 0 bis 65 000 HTTP Keep Alive Versuche fest Werkeinstellung 100 Versuche Modbus TCP IP Legt die verf gbare Anzahl an Modbus TCP IP 16 bis 64 Serververbindungen Server Verbindungen fest Werkeinstellung 32 Modbus Broadcast Legt fest wie Modbus TCP IP Meldungen mit Deaktiviert Aktiviert Unit ID 0 im seriellen Subnetzwerk behandelt oder Aktiviert mit werden Deaktiviert alle Meldungen werden R ckmeldung ignoriert Aktiviert alle Meldungen werden als Werkeinstellung Broadcasts an serielle Schnittstellen behandelt Deaktiviert f r die keine Antwort erwartet wird Aktiviert mit R ckmeldung alle Meldungen werden als normale Meldungen an serielle Schnittstellen behandelt f r die eine Antwort erwartet wird Modbus TCP Diese Einstellung legt fest ob Modbus TCP IP Deaktiviert oder
64. Les pages de donn es en temps r el affichent les mesures de base des appareils s lectionn s en temps r el ainsi que les r sum s des appareils Pages d appareil unique Pour afficher les donn es en temps r el dans un tableau acc dez au menu Surveillance et s lectionnez un appareil sous Donn es en temps r el gt Pages d appareil unique Param tres des mesures de base En haut de l cran s lectionnez Courant de Permet de s lectionner les grandeurs charge Puissance Tension L L ou Tension L N afficher sur le graphique cadran pour afficher la grandeur en question sur le analogique graphique a cadran analogique REMARQUE Les cadrans analogiques ne sont pas disponibles pour tous les types d appareil Par d faut les cadrans ajustent automatiquement la Permet de contr ler la plage affich e plage affich e Pour utiliser une plage fixe par les cadrans analogiques s lectionnez Plage Le tableau ci dessous explique comment configurer la plage des cadrans analogiques Figure 30 Page Mesures de base Mesures de base Building Main CM4000 2010 02 15 12 41 42 200 200 1 00 100 o gan o E 319 la A 338 Ib A 327 Ic A ls 185 319 290 lo 186 338 2 lc 188 27 381 moyen 188 228 389 Re u o 25 2 It nal aa Puissance Active kW 143 22 300 R sctive k VAR A 135 Apperente kVA 158 277 229 Facteur de puissance total 0 849 retard 0 945 retard 0 943 retard Tensi
65. Proxyserver Meldungen von entfernten Clients an entfernte Aktiviert Modbus TCP IP Ger te die im EGX definiert Werkeinstellung sind weitergeleitet werden Aktiviert Timeout Modbus Die Zeit w hrend der das EGX auf die Antwort 0 1 bis 10 TCP IP Client eines entfernten Modbus TCP IP Ger ts auf eine Werkeinstellung durch das EGX eingeleitete Modbus TCP IP 5 Sekunden Anforderung wartet Timeout Modbus Die Zeit w hrend der das EGX auf die Antwort 1 bis 10 TCP IP Client eines entfernten Modbus TCP IP Ger ts auf eine Werkeinstellung Verbindung durch das EGX eingeleitete Modbus TCP IP 2 Sekunden Verbindungsanforderung wartet Modbus TCP IP Ein Timer der eine Modbus TCP IP Verbindung 0 bis 32 767 Sekunden Server Verbindung nach einer festgelegten Leerlaufzeit schlie t Der Werkeinstellung 0 Leerlaufzeit Wert 0 deaktiviert diese Einstellung PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Erkennung identischer IP Adressen W hrend das EGX an Ihr Netzwerk angeschlossen ist ver ffentlicht es seine IP Adresse Zur Vermeidung von Konflikten aufgrund doppelt vergebener IP Adressen wird vom EGX das ARP Protokoll Address Resolution Protocol benutzt Damit wird festgestellt ob ein anderes Ger t in Ihrem Netzwerk die gleiche IP Adresse verwendet In der nachstehenden Tabelle 4 wird erl utert wie das EGX mit einer doppelt vergebenen IP Adresse umgeht sobald es sie erkannt hat Tabelle 4 Szenari
66. Reservados todos los derechos 63230 319 216B2 11 2011 Indice alfab tico A acceso a la EGX a trav s de una red 2 ARP protocolo de resoluci n de direcciones 8 B bot n Puntos de datos registro de datos de intervalo 44 C certificado de confianza n mero de puerto HTTPS 7 c digos de error registro cronol gico de datos 43 comprobaci n de las comunicaciones 55 automatizada 55 manual 55 conexi n de dispositivos 12 conexiones con dispositivos remotos 10 configuraci n de Ethernet avanzada 6 de Ethernet y TCP IP 5 de lecturas b sicas 37 de los puertos serie 8 del puerto serie avanzada 9 EGX 5 lista de dispositivos 13 consulta Web de Microsoft registro de datos de intervalo 44 control 49 correo electr nico exportaci n del registro de dispositivos 19 registro de datos de intervalo 44 cuentas de usuario configuraci n 28 D datos en tiempo real 37 detecci n de direcciones IP duplicadas 8 detecci n de dispositivos 15 diagn sticos 50 dispositivos Modbus detecci n 15 E EGX inicio de sesi n 2 interfaz de usuario 3 lista de dispositivos 12 estad sticas 50 interpretaci n 51 exportaci n del registro de dispositivos 19 configuraci n 19 F fecha y hora configuraci n 23 filtrado de Modbus TCP IP configuraci n 25 firmware actualizaci n 58 actualizaci n mediante FTP 56 obtenci n de nuevo 57 formato de registro de datos 42 FTP exportaci n del registro de disposit
67. SNAP envoy es travers une connexion Par d faut Ethernet Il Ethernet Type de support D finition de la connexion Ethernet 10T 100Tx Auto physique ou du type de support 10BaseT HD 10BaseT FD 100BaseTx HD 100BaseTx FD Par d faut 10T 100Tx Auto Obtenir une Obtention automatique d une adresse IP Option activ e ou d sactiv e adresse IP partir d un serveur BootP Par d faut D sactiv automatiquement REMARQUE Impose la prise en charge de l administration r seau Adresse IP Saisie de l adresse IP statique de la Par d faut 169 254 0 10 passerelle EGX Masque de sous Saisie de l adresse IP Ethernet du masque Par d faut 255 255 0 0 r seau de sous r seau Passerelle par Saisie de l adresse IP de la passerelle Par d faut 0 0 0 0 d faut routeur utilis e pour les communications sur r seau tendu Passerelle Ethernet PowerLogic EGX300 Configuration Param tres Ethernet avanc s 63230 319 216B2 11 2011 ATTENTION MAUVAISES PERFORMANCES DU R SEAU Les param tres Ethernet avanc s de la passerelle EGX ne doivent tre modifi s que par des techniciens qualifi s qui ont lu et assimil la documentation relative ces param tres Le non respect de ces instructions pourrait entra ner une baisse des performances du r seau 1 Cliquez sur Avanc la page Ethernet et Ouvre la page des param tres Ethernet TCP IP avanc s 2 Configurez les param tres Ethern
68. Schedule Logging Interval Hourly Daily Weekly Monthly Time of Day 00 00 Day of the Week Day ofthe Month 1 Ej FTP Parameters Server IP Address 0 L0 0 0 Server TCP Port 21 Directory Username user Password eececececee Passive Test FTP Apply NOTE If the transport is scheduled for Hourly or Logging interval the incremental check box will automatically be selected O 2011 Schneider Electric All Rights Reserved 21 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 HTTP Export 1 From the Setup page click Device Log Opens the Device Log Export page Export 2 Select HTTP as the mode of transport Opens the HTTP device log export options 3 Enable the Incremental check box Selects only new data logged since the last NOTE If the transport is scheduled for good send interval to be sent Hourly or Logging interval the incremental check box will be automatically selected NOTE If the Incremental check box is not selected the whole log file is sent via HTTP on each scheduled interval 4 Select Hourly Daily Weekly Monthly or Selects how often the data logs are Logging interval transported 5 Depending on which options you selected Selects when the data logs are transported in the previous step select the time of day day of the week and or day of the month 6 Inthe Server IP Addre
69. Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Fecha y hora Pasarela Ethernet EGX300 de PowerLogic Configuraci n Figura 17 P gina Exportaci n del registro de dispositivos HTTP Exportaci n del registro de dispositivos O Desactivado O Correo electr nico OFTP HTTP Incremental O Intervalo de registro O Cada hora Diariamente Semanalmente Mensualmente Hora del dia 00 00 D a de la semana Domingo D a del mes 1 Direcci n IP del servidor 0 0 0 J0 Puerto TCP del servidor 80 Ruta Nombre de campo datafile1 Nombre de host nombre de host virtual opcional Nombre de usuario user Contrase a SSL Exportaci n manual Correo electr nico de prueba Probar FTP Probar HTTP La p gina Fecha y hora le permite ajustar la fecha y la hora de la EGX 1 En el men Configuraci n haga clic en Abre la p gina Fecha y hora Fecha y hora 2 Configure a o mes dia hora minutos y Establece la fecha y la hora segundos 3 Seleccione la Desviaci n de zona Ajusta el reloj a la zona horaria seleccionada horaria 4 Para establecer que el reloj se ajuste Le permite establecer que el reloj se ajuste autom ticamente al horario de verano autom ticamente al horario de verano habilite la casilla de verificaci n Habilitar ajuste a
70. Sie sich an Ihren Netzwerkadministrator 3 Geben Sie Ihre IP Adresse die Eingabe der Ethernet Parameter f r das EGX Subnetzmaske und die dem EGX durch HINWEIS Wenn Sie eine IP Adresse Ihren Netzwerkadministrator zugewiesene eingeben die bereits in Verwendung ist Standard Gateway Adresse ein werden Sie zur Auswahl einer anderen IP Adresse aufgefordert Siehe Erkennung identischer IP Adressen auf Seite 8 4 Klicken Sie auf bernehmen Aktualisierung der Ethernet und TCP IP Einstellungen f r das EGX Tabelle 2 enth lt eine Liste der Optionen Abbildung 3 Ethernet amp TCP IP Seite Ethernet amp TCP IP Ethernet MAC Adresse 00 80 67 80 54 E5 Rahmenformat Ethernet II x bertragungsmedium 10T 100Tx Auto IP Parameter C IP Adresse automatisch erhalten IP Adresse 169 254 JO 10 Subnetzmaske 255 255 255 0 Standard Gateway 169 254 0 110 Erweitert bernehmen Tabelle 2 EGX Ethernet und TCP IP Einstellungen Rahmenformat Auswahl des Formats in dem Daten ber eine Ethernet Il 802 3 SNAP Ethernet Verbindung gesendet werden Werkeinstellung Ethernet Il bertragungs Festlegung der physikalischen 10T 100Tx Auto medium Ethernet Verbindung oder 10BaseT HD des bertragungsmediums 10BaseT FD 100BaseTX HD e 100BaseTX FD Werkeinstellung 10T 100Tx Auto IP Adresse F r den automatischen Abruf einer IP Adresse Aktiviert oder Deakt
71. TCP IP Settings oooococonincccnonacccncocnnnoncncnnonn nono non nnnnernnnn ern 5 Advanced Ethernet Settings 6 Duplicate IP Address Detection 8 Serial zo 5552 ese teed reste cues A E ENES 8 Advanced Serial Port Settings 9 Remote Device Connections ss 10 EGX Device List u ee ds 12 Connecting Devices to an EGX nennen 12 Device List Setup it li 13 Device DisCovery iscsi ee Ri area eis 15 Device LOGGING pesisiran tera ica aisla 17 Interval Data Logging ococococccccnnnnocococcnonononononcncnnnc nn nn conan nn cn conan 17 Set Up Interval Logging ss 17 TOPICS 10 WOG 2 A nant te 18 Device Log Export minents antenne detente 19 E mail EXPO ces u a entier Oda 19 Fel EXD OM e eset A E eten wet enee et eee 21 HTTP EXPO ee en ner ioe anon hes 22 Date nd Time sue rennen tes annee bes e dans ES 23 Network Time Synchronization ern 24 SNMP Par meters i sees une ai 25 Modbus TCP IP Filtering ss 25 Documentation Links unis 26 User Accounts cis 28 Web Page ACCESS miii a Lara anne 29 Add Remove Custom Web Pages 30 Adding Web Pages Using FTP 30 Deleting Web Pages Using FTP 30 Add Remove Web Pages to from the Web Interface 31 Pr f rences ent ii 32 Viewable Device Types un 33 Audit Trail 2 2 anne dr Pr he annee Tite 33 System ACCESS Point arrite konatan rusinii annaia koitadu iesin 35 Monitoring uussnsersnnnennnnnennnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnn
72. ae nn de ii 50 Interpretation des statistiques 51 Lecture de registres d appareils Verification des communications V rification automatique des communications 55 V rification manuelle des COMMUNICATIONS 55 Maintenance nnunrennssnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnnennnsnnnnnnnnnnn nn 56 Logiciel embarqu firmware nunne nnn Recherche de la version du logiciel embarqu Version du composant binaire ex cutable du logiciel embarqu 57 Version du composant image de fichier de logiciel embarqu 57 Obtention du dernier logiciel embarqu uuernsesesnnessnnnnesnnnnn nenne ennn nennen 57 Mise jour du logiciel embarqu firmware 58 Annexe A Protocoles Ethernet pris en charge Materiel E EAE Eee ante Annexe B Types d appareil pris en charge 60 ii 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 INTRODUCTION Ressources suppl mentaires 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Introduction L EGX300 est un composant Ethernet qui constitue une interface transparente entre les r seaux Ethernet et les appareils situ s sur le terrain compteurs appareils de mesure relais
73. ala la versi n del firmware de la EGX inferior izquierda de la p gina NOTA Si ha actualizado el firmware recientemente pulse F5 para actualizar la p gina web y actualizar el n mero de firmware que aparece en ella 3 Tambi n puede seleccionar Diagn sticos Tambi n se ala la versi n del firmware de gt Estad sticas para ver la versi n del la EGX firmware en la secci n Informaci n de pasarela Versi n del firmware del componente de imagen de archivo Acci n Resultado 1 Inicie el Explorador de Windows escriba Abre el cuadro de di logo Iniciar sesi n ftp y la direcci n IP de la EGX en el como cuadro Direcci n por ejemplo ftp 169 254 0 10 y luego pulse Intro 2 Escriba el nombre de usuario Abre una sesi n de FTP con la EGX Administrator y la contrase a de administrador en los cuadros de texto y luego haga clic en Iniciar sesi n 3 Localice el archivo version txt y luego Muestra la versi n del firmware de la imagen haga doble clic en el archivo para abrirlo de archivo Obtenci n de firmware nuevo 1 Inicie el explorador web escriba Abre el sitio web de PowerLogic www powerlogic com en la barra de direcciones y luego pulse Intro 2 Seleccione su pa s y luego haga clic en Go Abre el sitio web PowerLogic de su pa s Ir NOTA Si ha seleccionado Estados Unidos vaya al paso 3 De lo contrario siga la navegaci n del sitio web espec fico del pa s para obtener el firmwar
74. angezeigt werden entsprechen dem Datum und der Uhrzeit im ausgew hlten Ger t Wenn dieser Parameter f r eine R ckstellung ausgew hlt ist werden das Datum und die Uhrzeit des EGX an das Ger t bertragen Die Werte f r Datum Uhrzeit werden nur dann gemeldet wenn das Ger t sie unterst tzt Wenn beispielsweise das Ger t den Min Max Wert f r Datum Uhrzeit letzter Reset nicht unterst tzt wird hier kein Eintrag f r den Wert Min Max angezeigt 49 PowerLogic Ethernet Gateway EGX300 Diagnose DIAGNOSE 63230 319 216B2 11 2011 F r den Zugang auf die Diagnose Webseiten Links klicken Sie auf Diagnose in der EGX Men leiste Statistik Diese Seite zeigt seit der letzten Aktivierung des EGX kumulierte Werte an Wenn die Stromversorgung des EGX ausf llt oder das Ger t wegen einer Konfigurations nderung oder eines anderen Ereignisses zur ckgestellt wird werden alle kumulierten Werte auf null zur ckgestellt 1 Klicken Sie im Diagnose Men auf Statistik 2 Zeigen Sie die Daten an 3 Klicken Sie auf R cksetzen Abbildung Einblendung der Statistikseite siehe nachstehende Abbildung 47 Weitere Informationen hierzu finden Sie nachstehend unter Statistik auswerten R cksetzung der kumulativen Diagnosedaten des EGX auf 0 47 Seite Statistik Bootzeit 2010 02 15 12 20 02 Statistik Aktuelle Uhrzeit 2010 02 16 06 28 16 Verbindungss
75. d appareils de trois fagons par courrier lectronique FTP ou HTTP Chaque m thode est d crite dans les sections suivantes REMARQUE Si les serveurs de courrier lectronique FTP ou HTTP ne se trouvent pas sur le m me segment de r seau Ethernet que la passerelle EGX assurez vous que les parametres de passerelle EGX par d faut sont correctement configur s Voir Parametres Ethernet et TCP IP page 5 Exportation par courrier lectronique 1 Dans la page Configuration cliquez sur Exporter le Ouvre la page Exporter le journal journal de l appareil de l appareil 2 S lectionnez Courrier lectronique comme mode Affiche les options d exportation d acheminement des journaux d appareil par courrier lectronique 3 Cochez l option Incr mentale S lectionne uniquement les nouvelles donn es enregistr es depuis la derni re exportation de donn es r ussie REMARQUE Sil acheminement est r gl sur les options Horaire ou Intervalle d enregistrement la case cocher Incr mentale est automatiquement s lectionn e REMARQUE Si l option Incr mentale est d sactiv e la totalit du fichier journal est envoy e en fichier joint chaque intervalle d fini 4 S lectionnez Horaire Quotidien Hebdomadaire S lectionne la fr quence d envoi Mensuel ou Intervalle d enregistrement des journaux de donn es 5 Selon les options sp cifi es l tape pr c dente Sp cifie que
76. de rea extendida WAN Esta capacidad permite utilizar software de supervisi n para acceder a la informaci n de los dispositivos y recolectar datos establecer tendencias gestionar alarmas y eventos efectuar an lisis y ejecutar otras funciones La EGX300 permite generar informes de datos en tiempo real a partir de muchos tipos de dispositivos corrientes y proporciona varias funciones espec ficas de estos tales como informes de p ginas de resumen incorporadas de dispositivos y circuitos registro de datos incorporado y establecimiento de tendencias en tiempo real Figura 1 Descripci n general de la EGX300 Ver datos del Vistas en tiempo real dispositivo con un Tendencias en sencillo navegador tiempo real sin software P ginas web de la EGX300 Tendencias de los Restablecimientos de control registros de datos Extraiga a p ginas web E EGX100 informaci n proveniente de ss otras pasarelas PowerLogic a gt e interfaces TCP IP 7 y Modbus como ECC21 U a y PM8ECC HH 10N6200 PM800 Micrologic Sepam EGX300 Documentaci n Visite www powerlogic com y seleccione su pais Vaya a la documentaci n de la EGX Firmware Visite www powerlogic com y seleccione su pais Vaya a descargas de EGX consulte Obtenci n de firmware nuevo en la pagina 57 para obtener m s informaci n Pasarela Ethernet EGX300 de PowerLogic M Acceso a la EGX a trav s de una red ACCESO A LA EGX
77. de acceso comunidad de s lo lectura y el nombre de la de las comunidades comunidad de lectura y escritura 4 Haga clic en Aplicar Guarda los valores del SNMP Figura 20 P gina Par metros del SNMP Par metros del SNMP Activar SNMP AAA Contacto del sistema Admin Nombre del sistema John Smith Ubicaci n del sistema Office 1 Nombre de comunidad de s lo lectura public Nombre de comunidad de lectura y escritura private Esta funci n permite al administrador asignar el nivel de acceso que los clientes Modbus TCP IP tienen a los dispositivos locales o remotos conectados a la EGX NOTA Existe una direcci n Modbus TCP IP an nima que se puede configurar como S lo lectura o Ninguna Si la configura como S lo lectura permitir que cualquier cliente Modbus TCP IP que no est en la lista de filtrado acceda a los dispositivos esclavos en serie con acceso de s lo lectura Si la configura como Ninguna bloquear a todos los clientes Modbus TCP IP que no est n en la lista de filtrado 1 Enel men Configuraci n haga clic Abre la p gina Filtrado de Modbus TCP IP en Filtrado de Modbus TCP IP 2 Marque la casilla de verificaci n Activa el filtrado Activar filtrado 3 En la columna Direcci n IP Introduce la direcci n IP de un cliente introduzca la direcci n del cliente Modbus TCP IP que tendr acceso a los dispositivos Modbus TCP IP conectados a la EGX
78. de diagn stico que se utilizan para resolver problemas de la red Esta p gina contiene tambien informaci n acerca de la EGX especifica del usuario incluido el n mero de serie la fecha de fabricaci n y la direcci n de control de acceso de medios MAC 50 Lectura de registros de Permite que los usuarios lean datos de registro 54 dispositivo procedentes de dispositivos locales y remotos conectados a la EGX 5 6 Comprobaci n de las Verifica el buen estado de las comunicaciones de comunicaciones todos los dispositivos configurados en la EGX Mantenimiento Registro de mantenimiento Muestra la fecha la hora y el usuario que ha 5 realizado el ltimo mantenimiento del equipo y proporciona datos de entrada sobre el mantenimiento realizado 4 O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuraci n CONFIGURACION Para acceder a los vinculos de la pagina web Configuraci n haga clic en Configuraci n en la barra de men s de la EGX Configuraci n de Ethernet y TCP IP 1 En el men Configuraci n haga clic en Abre la pagina Ethernet y TCP IP Ethernet y TCP IP 2 Seleccione el formato de trama y el tipo Selecciona el formato de trama y el tipo de medio de medio Si no los conoce p ngase en contacto con el administrador de la red 3 Introduzca su direcci n IP la m scara Introduce los par metros de Ethernet para la EGX de
79. de protection automates programmables unit s de contr le commandes de moteur et autres appareils qui communiquent au moyen des protocoles Modbus Jbus ou PowerLogic La passerelle EGX300 utilise le protocole Modbus TCP IP pour acc der aux informations des appareils sur site via un r seau local LAN ou un r seau tendu WAN Cette fonctionnalit permet d utiliser un logiciel de surveillance qui acc de aux informations des appareils et r alise les fonctions de collecte de donn es courbes de tendances gestion d alarmes amp venements analyses et autres L EGX300 prend en charge la communication des donn es en temps r el de nombreux types d appareil courants et offre plusieurs fonctionnalit s sp cifiques Les rapports disponibles pr sentent par exemple des pages de recapitulatifs internes sur l appareil et le circuit des calculs de tendances en temps r el ou des journaux de donn es internes Figure1 Pr sentation de EGX300 Affichage en temps r el Tendances en temps r el Affichage des donn es d appareil a l aide d un simple navigateur pas de logiciel sp cial Pages Web de l EGX300 i A M AM M Tendances des journaux de donn es R initialisation des commandes Affiche sous forme de pages EGX100 EGX300 Web les informations d autres passerelles PowerLogic et d interfaces Modbus TCP IP 8 r comme les modules ECC21 et I ww PM8ECC 98
80. der Download Seite 4 Klicken Sie auf den Link EGX300 Firmware Einblendung der Seite EGX300 Firmware 5 Klicken Sie auf den Link mit der Firmware Einblendung des Dialogfelds f r den Datei Datei egxxxxx bin wobei xxxx die Firmware Download und dann des Dialogfeldes Versionsnummer ist und dann auf Speichern unter Speichern 6 W hlen Sie im Dialogfeld Speichern unter Speicherung der Firmwaredatei im das lokale Verzeichnis bzw den Dateiordner angegebenen Verzeichnis bzw Ordner aus in dem die Firmwaredatei gespeichert werden soll oder erstellen Sie ein lokale Verzeichnis bzw einen Dateiordner und klicken Sie auf Speichern 7 Klicken Sie auf den Link egxxxxx upd wobei Einblendung des Dialogfelds f r den Datei xxxx die Firmware Nummer ist und dann auf Download und dann des Dialogfeldes Speichern Speichern unter 8 W hlen Sie im Dialogfeld Speichern unter Speicherung der Firmwaredatei upd im das lokale Verzeichnis bzw den Dateiordner angegebenen Verzeichnis bzw Ordner aus in dem die Firmwaredatei gespeichert werden soll oder erstellen Sie ein lokale Verzeichnis bzw einen Dateiordner und klicken Sie auf Speichern 2011 Schneider Electric Alle Rechte vorbehalten 57 PowerLogic Ethernet Gateway EGX300 Firmware Firmware aktualisieren 58 63230 319 216B2 11 2011 W hrend die Firmware heruntergeladen wird darf die Stromversorgung des EGX nicht unterbrochen
81. desee ver Cuando asigne un grupo de informes a un canal ver todos los mensajes que se generen en ese grupo de informes Los canales de mensajes son los siguientes e Archivo de registro de mantenimiento incorporado de la EGX Servidor Syslog remoto Syslog es un est ndar para el registro de mensajes e Correo electr nico Todos los mensajes llevan una marca de fecha y hora e incluyen informacion de grupo de informes y de identificaci n del usuario 2011 Schneider Electric Reservados todos los derechos 33 Pasarela Ethernet EGX300 de PowerLogic M Configuraci n 34 63230 319 216B2 11 2011 La p gina Historial de auditor a se divide en tres cuadros que corresponden a los tres canales de mensajes Registro de mantenimiento Syslog y Correo electr nico Consulte la Figura 28 de la p gina 35 Es posible configurar de manera independiente los mensajes que se env an a cada canal En la ventana Configuraci n haga clic en Historial de auditor a Se abre la p gina Historial de auditor a Siga las instrucciones de la tabla siguiente Tabla 14 Configuraci n de Historial de auditor a Registro de mantenimiento Controla los tipos de A medida que se generen los Marque las opciones de informe informes cuyos mensajes mensajes estos aparecer n en que desee incluir desea que se visualicen en el registro de mantenimiento Predeterminado No hay el registro de mensajes incorporado de la EGX ninguna opci n mar
82. die vor potenziellen Gefahren warnen oder die Aufmerksamkeit auf Informationen lenken die eine Prozedur erkl ren oder vereinfachen Der Zusatz eines Symbols zu den Sicherheitshinweisen Gefahr oder Warnung deutet auf eine elektrische Gefahr hin die zu schweren Verletzungen f hren kann wenn die Anweisungen nicht befolgt werden Dieses Symbol steht f r eine Sicherheitswarnung Es macht auf die potenzielle Gefahr eines Personenschadens aufmerksam Beachten Sie alle Sicherheitshinweise mit diesem Symbol um schwere Verletzungen oder Todesf lle zu vermeiden A GEFAHR GEFAHR weist auf eine unmittelbar gef hrliche Situation hin die bei Nichtbeachtung zu schweren Verletzungen oder Todesf llen f hrt A WARNUNG WARNUNG weist auf eine potenziell gef hrliche Situation hin die bei Nichtbeachtung zu schweren Verletzungen oder Todesf llen f hren kann AACHTUNG ACHTUNG weist auf eine potenziell gef hrliche Situation hin die bei Nichtbeachtung zu leichten Verletzungen f hren kann ACHTUNG ACHTUNG ohne ein Warnsymbol weist auf eine potenziell gef hrliche Situation hin die bei Nichtbeachtung zu Sachsch den f hren kann NOTE Bietet zus tzliche Informationen zur Kl rung oder Vereinfachung einer Prozedur Elektrisches Ger t sollte stets von qualifiziertem Personal installiert betrieben und gewartet werden Schneider Electric bernimmt keine Verantwortung f r jegliche Kon
83. disponible Lorsque l adresse est disponible la passerelle EGX l utilise Port s rie 1 Dans le menu Configuration cliquez sur Ouvre la page Port s rie Port s rie 2 S lectionnez l interface physique le mode S lectionne les options de port s rie de transmission la vitesse la parit et le d lai de r ponse voir le Tableau 5 page 9 3 Cliquez sur Appliquer Met jour les param tres du port s rie de la passerelle EGX Figure 5 Page Port s rie Port s rie Interface physique RS485 2 fils Mode de transmission Automatique B Vitesse de transmission 19200 amp Parit Paire y D lai d attente de r ponse B PB Secondes Avanc Appliquer 8 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Configuration Tableau 5 Param tres de port s rie option ES Permet de s lectionner le c blage RS 485 4 fils RS 485 2 fils ou RS 232 physique du port s rie de la passerelle Par d faut RS 485 2 fils EGX Mode de Permet de d terminer comment les Automatique transmission donn es sont transmises travers une Modbus ASCII connexion s rie REMARQUE Le mode automatique permet simultan ment de communiquer avec les appareils esclaves Modbus RTU PowerLogic SY MAX et Jbus sur la m me guirlande Vitesse de Permet de s lectionner la vitesse de 2400 4800 9600 192
84. dispositivo lista desplegable 6 Enel cuadro de texto Nombre del Introduce el nombre del dispositivo dispositivo escriba el nombre del dispositivo 7 En el cuadro de texto ID local escriba la Introduce la direcci n local del dispositivo direcci n del dispositivo esclavo serie si est en el puerto serie o escriba la direcci n que desee utilizar para acceder a un dispositivo remoto 8 Enel cuadro de texto ID remoto escriba la Introduce la direcci n del dispositivo remoto direcci n del dispositivo remoto 9 Repita los pasos 4 a 8 hasta introducir Introduce todos los dispositivos conectados todos los dispositivos 10 Haga clic en Aplicar Actualiza los valores de Lista de dispositivos Este par metro de configuraci n s lo se puede cambiar si est deshabilitado el registro de datos para el dispositivo que se est actualizando Consulte Registro de dispositivos en la p gina 17 Figura 10 P gina Lista de dispositivos Lista de dispositivos Numero de dispositivos visualizables ls E Tipo de dispositivo Nombre del dispositivo ID local mmo B PM800_Bldg1_Feeder1 3 CM4000 al CM4_Bldgt_Maint ES CM2000 y CM2_Bldg2_Feeder2 5 PM9c PM9c_Bidg2_Feeder2 CH Sepam 2000 Sepam _Bldg 2_CB_1 7 Sepam Series 40 Sepam4_Bldgt _CB_2 8 Model98 modbus Model98_Bldg1_Switchgear1 9 Modbus 13 Pasarela Ethernet EGX300 de PowerLogic 632
85. entfernter Ger te Definiert Anzeige des Ger tetyps der f r das entsprechende Ger t festgelegt wurde Zugewiesen Damit k nnen Sie den Ger tetyp aus einer Dropdown Liste zuweisen e Hier k nnen Sie einen benutzerdefinierten Namen f r das Ger t eingeben Lokale ID Anzeige der lokalen ID Nam Anzeige der Fern ID tat Status Anzeige des Erkennungs oder G ltig Unbekannt berpr fungsstatus Fehlgeschlagen Gefunden Erkennung oder Versuch 16 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Ger teaufzeichnung Intervalldatenaufzeichnung Intervallaufzeichnung einrichten 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Setup Die Aufzeichnung ist f r jeden durch das EGX unterst tzten Ger tetyp verf gbar Das EGX kann Daten aufzeichnen die von angeschlossenen lokalen und entfernten Ger ten in vordefinierten Intervallen 5 10 15 20 30 und 60 Minuten empfangen werden Nachfolgend wird erl utert wie das EGX Daten aufzeichnet und wie die Aufzeichnung f r ein Ger t eingerichtet wird Viele Ger te in einem Leistungs berwachungssystem k nnen keine Daten in einem nichtfl chtigen Speicher ablegen Das EGX300 bietet Datenaufzeichnung f r bis zu 64 seriell und entfernt angeschlossenen Ger ten in vordefinierten Intervallen Das EGX legt die aufgezeichneten Daten in nichtfl chtigen FIFO Dateien First In First Out ab Die Aufzeic
86. env e autom ticamente el archivo de registro de datos a trav s de FTP el par metro Exportaci n del registro de dispositivos tiene que configurarse para FTP consulte Exportaci n por FTP en la p gina 21 1 Cree una carpeta en su equipo como Crea una carpeta para almacenar el registro de c egx_logs datos de la EGX 2 Inicie el Explorador de Windows escriba Abre el cuadro de di logo Iniciar sesi n ftp y la direcci n IP de la EGX en el como cuadro Direcci n por ejemplo ftp 169 254 0 10 y luego pulse Intro 3 Escriba el nombre de usuario Inicia una sesi n de FTP con la EGX y muestra Administrator y la contrase a de los archivos almacenados en la EGX administrador en los cuadros de texto y luego haga clic en Iniciar sesi n 4 Vaya al directorio logging data en Abre el directorio de registro de datos en la EGX la EGX 5 Copie el archivo de registros y luego Copia el registro de datos en la carpeta p guelo en la carpeta creada en el paso 1 O 2011 Schneider Electric Reservados todos los derechos 43 Pasarela Ethernet EGX300 de PowerLogic Supervisi n Obtenci n de un registro de datos de intervalo mediante el bot n Puntos de datos Obtenci n de un registro de datos de intervalo mediante la funci n de consulta Web de Microsoft Obtenci n de un registro de datos de intervalo mediante correo electr nico Obtenci n de un registro de datos de intervalo mediante HTTP 44
87. envio 0 O CSP Error general 0 Env o correcto 0 Error de conexi n 0 Error de envio 0 Espacio total 245889 KOctetos Error t 0 Espacio libre 243918 KOctetos 99 aL Restablecer O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Diagn sticos Interpretaci n de las estadisticas Estado de conexi n Cadena de estado que representa la velocidad y la configuraci n bidireccional que se utiliza para comunicarse con el dispositivo conectado Tramas transmitidas satisfactoriamente Contador que aumenta cada vez que se envia una trama correctamente Colisiones Contador que aumenta cada vez que se reenvia una trama debido a detecci n de colisiones Colisiones excesivas Contador que aumenta cada vez que no se puede enviar una trama porque ha alcanzado el estado de colisi n m xima basado en el algoritmo de retroceso exponencial binario truncado Tramas recibidas satisfactoriamente Contador que aumenta cada vez que se recibe una trama correctamente Errores de CRC de tramas Contador que aumenta cada vez que se recibe una trama que contiene una suma de verificaci n CRC que no coincide con la calculada Errores de alineaci n Contador que aumenta cada vez que se recibe una trama que contiene un error de suma de verificaci n CRC y que no termina en un borde de trama de 8 bits Tramas demasiado largas Contador que aumenta cada vez que se recibe una
88. gt D Maintenance gt French gt l Maintenance y English PT Maintenance Engish Maintenance y English Po Maintenance y Engish Maintenance y English Apply O 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Web Page Access 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup 1 From the Setup menu click Web Page Access Opens the Web Page Access page 2 Select the access level None Read only or See Table 12 below for an explanation of Full that each user group will have for the web access levels for each group pages 3 To allow Guest access to the web page select Allows the default Guest group to access Read only under the Guest column the web page NOTE If the Guest group is Read only other groups may only be set to Read only or Full 4 Repeat steps 2 and 3 for the options in each Selects the access level for each web section page 5 Click Apply Saves the password settings Table 12 Group Access Full access to all web pages NOTE We recommend that you change the default administrator password for system security the first time you log in Three user defined Choosing from the following options the administrator assigns web groups page access for each group Access levels are as follows None a group has no access to selected web page Read only passwor
89. l Explorateur Windows de l Explorateur Windows 1 Lancez l Explorateur Windows tapez ftp Ouvre la bo te de dialogue Connexion en tant suivi de l adresse IP de la passerelle EGX que ex ftp 169 254 0 10 dans la barre d adresses puis appuyez sur Entr e 2 Tapez le nom d utilisateur Administrator et Ouvre une session FTP avec la le mot de passe correspondant dans les passerelle EGX zones de texte appropri es puis cliquez sur Connexion 3 Ouvrez le dossier dans lequel la page Web Ouvre le dossier contenant la page Web est stock e cliquez avec le bouton droit sur personnalis e puis supprime le fichier le fichier supprimer puis choisissez Supprimer 4 Cliquez sur le bouton Fermer de la fen tre Ferme la fen tre de l Explorateur Windows de l Explorateur Windows 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Configuration Ajout Suppression de pages Web personnalis es l aide de l interface Web 1 Dans le menu Configuration cliquez sur Ouvre la page Acc s aux pages Web Acc s aux pages Web 2 Cliquez sur Ajouter supprimer des pages Ouvre la page Ajouter supprimer des pages Web voir la Figure 25 Web 3 Si vous avez ajout des pages Web S lectionne ou d s lectionne une page Web personnalis es aux dossiers EGX la liste personnalis e de ces fichiers apparait sous chaque nom de dossier S lectio
90. la direcci n IP del servidor al que se enviar n los correos electr nicos Puerto TCP del servidor Este es el n mero del puerto TCP de la direcci n IP del servidor El servidor SMTP requiere Esta casilla de verificaci n sirve iniciar sesi n para activar el inicio de sesi n a fin de recibir correos electr nicos El servidor SMTP requiere que se inicie una sesi n Nombre de usuario Nombre de usuario que utilizar la EGX para iniciar sesi n en el servidor SMTP Contrase a Clave que utilizar la EGX para iniciar sesi n en el servidor SMTP Informe Se trata de los cuatro tipos de informes cuyos mensajes se pueden reenviar Se pueden marcar todos los que desee Predeterminados Aplicar Haga clic en Aplicar para guardar las entradas que haya completado Haga clic en Predeterminados para devolver cada campo a su estado predeterminado Introduzca la direcci n del remitente emisor para los correos electr nicos M ximo de 49 caracteres Introduzca las direcciones de los destinatarios destinatario de todos los correos electr nicos de mensaje M ximo de 49 caracteres por direcci n Si no introduce una direcci n IP de un servidor no se enviar ning n correo electr nico Introduzca el n mero del puerto TCP El valor predeterminado es 25 Marque la casilla para empezar a a adir datos de inicio de sesi n Escriba el nombre de usuario que requiera el servidor SMTP m x 31 caracteres
91. la p gina Ethernet y TCP IP 4 Haga clic en Aceptar para aceptar los La EGX se reinicia cambios y restablecer la EGX Figura 4 P gina Configuraci n avanzada de Ethernet Configuraci n avanzada de Ethernet Periodo de vida 60 1 255 Saltos Mantenimiento de conexi n TCP 30 Segundos Tiempo de espera de BootP 6 Segundos Tiempo de espera de la cache ARP 15 Minutos Servidor FTP Activado _ Tiempo de inactividad de conexi n FTP 120 Segundos Tiempo de inactividad de conexi n HTTP 6 Segundos N mero de puerto HTTP B0 1 65536 N mero de puerto HTTPS 0 1 65535 M ximo de mantenimientos de conexiones HTTP 100 Conexiones servidor Modbus TCP IP 32 y Difusi n Modbus Desactivado iv Proxy MODBUS TCP Activado Tiempo de espera de cliente Modbus TCP IP 6 Segundos Tiempo de espera de conexi n de cliente Modbus TCP IP 2 o Segundos Tiempo de inactividad de conexi n de servidor Modbus TCP IP O Segundos Predeterminados Aplicar 6 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Tabla 3 Pasarela Ethernet EGX300 de PowerLogic Configuraci n Configuraci n avanzada de Ethernet de la EGX Opci n Descripci n Valor Periodo de vida Mantenimiento de conexion TCP Tiempo de espera de BootP Tiempo de espera de la cach ARP Servidor FTP Tiempo de inactividad de conexi n
92. lokale ID die gespeicherte Ger tebezeichnung sowie den gespeicherten Ger tetyp aus der Ger teliste an und fragt danach das Ger t ab Der durch die Abfrage erkannte Ger tetyp wird angezeigt und danach mit der vorangegangenen Definition verglichen Der Status zeigt dann an ob eine Abweichung erkannt wurde oder ob die vorher definierte Konfiguration g ltig ist HINWEIS Sie k nnen die Ger tebezeichnung und den Ger tetyp bearbeiten und einzeln ausw hlen welche Ger te in der Ger teliste gespeichert werden sollen Wenn allerdings die Aufzeichnung f r ein Ger t aktiviert ist k nnen Sie nur die Bezeichnung ndern 1 Klicken Sie im Setup Men auf Ger teliste Einblendung der Seite Ger teliste 2 Klicken Sie f r die Erkennung lokal angeschlossener Einblendung der Seite Ger te auf Erkennung Ger teerkennung 3 Geben Sie eine Startadresse und eine Endadresse Eingabe des Adressenbereichs f r i die Erkennung HINWEIS Ger te die zuvor in die Ger teliste mit Adressen lokale IDs au erhalb des Erkennungsbereichs eingetragen wurden werden berpr ft 4 Klicken Sie auf Erkennung starten um den Prozess Beginn der Erkennung aller anzuhalten klicken Sie auf Erkennung anhalten angeschlossenen und definierten HINWEIS Mit der Erkennungsfunktion werden nur Ger te lokale serielle Modbus Ger te die an das EGX angeschlossen sind gefunden Entfernte Ger te m ssen manuell hinzugef gt werden Siehe
93. on the EGX and as URL web links For information on loading documentation links see Documentation Links on page 26 To open a documentation link click the Documentation link at the top of the page then select the link you want Figure 45 Documentation Page Schneider PowerLogic EGX300 P Electric Home Documentation META OA Documentation owe r The EGX has the ability to manually execute one or more of a set of predefined reset commands per device type 1 From the Control menu click Resets Opens the Resets page 2 Select a device in the Resets list you want Selects a device and shows its reset options to view or reset and the date and time of the last reset 3 Select the device parameters you wantto Selects the reset operation to be performed on reset the selected device 4 Click Reset Send reset command s for the requested reset s to the selected device and displays the status Figure 46 Resets Resets CM3000 A1 Parameter Date Time Last Reset Date Time 2008 06 20 11 40 58 Min Max 2008 06 10 13 44 17 Peak Demand Current 2008 06 10 13 44 16 Peak Demand Power 2008 06 10 13 44 18 Accumulated Energy 2008 06 10 13 44 19 NOTE The date and time shown for the Date Time parameter is the current date and time in the selected device If this parameter is selected to be reset the EGX date and time will be
94. page 2 Select your physical interface Selects the serial port options transmission mode baud rate parity and response timeout see Table 5 on page 9 3 Click Apply Updates the EGX Serial Port settings Figure 5 Serial Port Page Serial Port Physical Interface R5485 2 wire Transmission Mode Automatic x Baud Rate 19200 M Parity Even El Response Timeout 3 Seconds 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Advanced Serial Port Settings 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup Table 5 Serial Port Settings option Besen NT Physical Interface Used to select how the EGX serial port is RS485 4 wire RS485 2 wire physically wired or RS232 Default RS485 2 wire Transmission Used to select how data is transmitted over Automatic Mode a serial connection Modbus ASCII NOTE Automatic mode allows you to communicate to Modbus RTU Jbus and PowerLogic SY MAX slave devices on the same daisy chain Baud Rate Used to select the data transmission speed 2400 4800 9600 19200 over a serial connection 38400 56000 or 57600 Default 19200 Parity Used to select the type of parity required to Even Odd or None check data accuracy by using a parity bit Default Even Response Timeout Used to select how long the EGX will wait 0 1 to 10 seconds to receive a resp
95. section File Image Component Firmware Version Launch Windows Explorer type ftp and Opens the Log On As dialog box the IP address of the EGX in the Address text box for example ftp 169 254 0 10 then press Enter 2 Type the user name Administrator and the Opens an FTP session with the EGX administrator password in the text boxes then click Log On Getting New Firmware Launch the web browser type Opens the PowerLogic website www powerlogic com in the Address text box then press Enter 2 Select your country then click Go Opens the PowerLogic website for your NOTE If you selected the United States COU Y continue to Step 3 Otherwise follow the country specific website navigation to get the EGX firmware 3 Click Support gt Downloads Opens the downloads page 4 Click the EGX300 Firmware link Opens the EGX300 Firmware page 5 Click the firmware file link egxxxxx bin Opens the File Download dialog box then where xxxx is the firmware version opens the Save As dialog box number then click Save 6 In the Save As dialog box select or create Saves the firmware file in the designated a local directory file folder where the directory folder firmware file will be stored then click Save 7 Click the egxxxxx upd link where xxxx is Opens the File Download dialog box then the firmware number then click Save opens the Save As dialog box 8 In the Save As dialog box select or create Sa
96. subred y la direcci n predeter NOTA Si introduce una direcci n IP que ya est minada de la pasarela asignadas a siendo utilizada por otro dispositivo se le pedir la EGX por el administrador de la red que seleccione una direcci n IP diferente Consulte Detecci n de direcciones IP duplicadas en la p gina 8 4 Haga clic en Aplicar Actualiza la configuraci n de Ethernet y TCP IP de la EGX Consulte la Tabla 2 a continuaci n para ver una lista de opciones Figura 3 P gina Ethernet y TCP IP Ethernet y TCP IP Ethernet Direcci n MAC 00 80 67 80 55 5F Formato de trama Ethernet II Y J Tipo de medio 10TH OOTx Auto Parametros IP Doktener una direcci n IP autom ticamente Direcci n IP 169 254 Lo ho Mascara de subred 255 255 0 0 Pasarela predeterminada 169 1254 0 10 Tabla 2 Configuraci n de Ethernet y TCP IP de la EGX Formato de trama el que se envian los datos a trav s de una conexi n Ethernet 10T 100Tx Auto Ethernet o el tipo de medio 10BaseT HD 10BaseT FD 100BaseTX HD 100BaseTX FD Predeterminado 10T 100Tx Auto Obtener una Se utiliza para obtener autom ticamente Activado o desactivado direcci n IP una direcci n IP de un servidor BootP Predeterminado Desactivado autom ticamente NOTA Requiere apoyo de la administraci n de la red Direcci n IP Sirve para introducir la direcci n IP Predeterminado 169 254 0 10 es
97. tendance 63230 319 216B2 11 2011 Permet de s lectionner le mode du graphique Permet de s lectionner la p riode consid r e pour le calcul de tendance Permet de lancer le calcul de tendance Permet d afficher le journal de toutes les valeurs chantillonn es au cours du calcul de tendance Rouvre la page de configuration Calcul de tendance en temps r el Figure 35 Calcul de tendance en temps r el Calcul de tendance en temps r el 2010 02 16 05 55 44 OAbsolue Relative 1 Minutes __ Acc s aux donn es Nouvelle s grandeur s 140 123 S A 88 70 05 54 41 380 05 54 53 380 05 55 05 380 05 55 17 380 05 55 29 380 05 55 41 380 Min Present Max Moyenne Building East Panel Puissance active totale kW 101 102 103 101 6 Building East Panel Puissance apparente totale KVA 103 104 105 1036 Building North Panel Puissance active totale kW 101 102 103 101 8 Building North Panel Puissance apparente totale kVA 113 115 116 114 4 Les pages Journaux d appareil fournissent des repr sentations graphiques et tabulaires des donn es enregistr es pour l appareil s lectionn Pour plus de d tails sur la configuration de l enregistrement des journaux d appareil voir Journaux d appareil page 17 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Surveillance Pages d appa
98. that increments each time a file is unable to be transferred due to the inability of the EGX to originate the transaction FTP Client Send OK A counter that increments after each successful transfer to an FTP server Connect Error A counter that increments each time the EGX is unable to connect to the FTP server Authentication Error A counter that increments each time the FTP server is unable to authenticate the User Password credentials Directory Error A counter that increments each time the FTP server is unable to locate the requested directory Send Error A counter that increments each time a file is unable to be transferred to the FTP server General Error A counter that increments each time a file is unable to be transferred due to the inability of the EGX to originate the transaction SMTP Client Send OK A counter that increments each time an e mail is sent successfully to the SMTP server Connect Error A counter that increments each time the EGX is unable to connect to the SMTP server Authentication Error A counter that increments each time the SMTP server is unable to authenticate the user or password credentials Send Error A counter that increments each time an e mail is unable to be sent to the SMTP server General Error A counter that increments each time an e mail is unable to be sent due to the inability of the EGX to create the e mail File System Total Space The total amount of the EGX disk space i
99. the Selects or deselects a device entry to be saved device you want to save to the Device List or removed 7 Click Apply in the Device Discovery Saves to the device list the device configuration page for all devices that have been marked to be saved 15 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Figure 12 Device Discovery Device Discovery 2008 12 09 11 39 24 m CM3000 CM3000 CM3360 A1 Valid CM4000 CM4000 _CM4260 A2 2 Valid PMG plogic PMB plogic im PM650 104 A3 Attempting Stop Discover Apply Table 8 Device Discovery Options MIN Senne Start End Address Defines the Modbus address range that will 1 to 247 be used to discover devices on the EGX Default Start 1 End 10 serial port Save Allows you to save the selected device to Enabled or Disabled the Device List Default Enabled Connection Displays the connection on which the Serial Port or IP Address for device was discovered or validated remote device validation Defined Lists the device type that was defined for this device Assigned Allows you to assign the device type from the drop down list Name Allows you to enter a custom name for the device Local ID Displays the Local ID Po Remote ID Displays the Remote ID Po Status Displays the discovery or validation status Valid Unknown Failed Found Discovering or Attempting 16 2011 Schnei
100. ticamente autom tica en los dispositivos seleccionados NOTA Haga clic en seleccionar todo para habilitar la escala autom tica en todos los dispositivos y en borrar para deshabilitarla en todos ellos En los dispositivos en los que se haya deshabilitado la escala Establece el rango de autom tica introduzca los l mites M n y M x de cada tipo de los indicadores indicador 3 Haga clic en Aplicar Actualiza los valores de escala autom tica Figura 31 Pagina de configuraci n de rangos Valores nominales min max Nombre del dispositivo Activar escala autom tica Intensidad A Potencia Tensi n L L Tensi n L N seleccionar todo borrar Min M x M n M x Min M x M n Max Building Main 0 100 100 100 0 100 o 100 Building West Panel 0 100 100 100 0 100 o 100 Building East Panel 0 100 100 100 o 100 o 100 Building North Panel 0 100 00 100 0 100 o 100 Las vistas de tablas Resumen de dispositivos proporcionan resumenes de uno o mas dispositivos seleccionados 1 En el men de Supervisi n haga clic en P ginas Amplia el rbol para posibilidades de de resumen de dispositivos selecci n de p ginas de resumen 2 Seleccione la p gina de resumen que desee ver Abre la lista de selecci n de dispositivos 3 Seleccione uno o varios dispositivos en la lista Selecciona uno o varios dispositivos Dispositivos disponibles y luego haga clic en para las opciones de resume
101. velocidad en baudios la paridad y el tiempo de espera de respuesta consulte la Tabla 5 en la p gina 9 3 Haga clic en Aplicar Actualiza la configuraci n del puerto serie de la EGX Figura 5 P gina Puerto serie Puerto serie Interfaz f sica RS485 4 hilos velocidad en baudios 19200 62 Modo de transmisi n Autom tico ga g v Paridad Par Tiempo de espera de respuesta 3 E Segundos O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Tabla 5 Pasarela Ethernet EGX300 de PowerLogic Configuraci n del puerto serie Configuraci n Opci n Descripci n Valor Interfaz fisica Sirve para seleccionar el modo de Modo de transmisi n Velocidad en baudios Paridad Tiempo de espera de respuesta cableado f sico del puerto serie de la EGX Se usa para seleccionar el modo de transmitir datos en una conexi n serie Se usa para seleccionar la velocidad de transmisi n de datos en una conexi n serie Se usa para seleccionar el tipo de paridad con que comprobar la precisi n de los datos mediante un bit de paridad Sirve para seleccionar el tiempo que esperar la EGX a recibir respuesta de un dispositivo serie RS485 4 hilos RS485 2 hilos o RS232 Predeterminado RS485 2 hilos Autom tico Modbus ASCII NOTA El modo Autom tico le permite comunicarse con dispositivos esclavos Modbus RT
102. web server functionality via TCP port 80 Hypertext Transfer Protocol Secure HTTPS HTTPS is a network protocol that handles the encrypted delivery of files and data on the World Wide Web with the use of SSL It provides secure web server functionality via TCP port 443 File Transfer Protocol FTP FTP is a network protocol that provides the ability to transfer files over the Internet from one computer to another Active and passive FTP modes are supported primarily using TCP port 21 Simple Network Management Protocol SNMP Based on MIB2 format SNMP provides the ability to store and send identifying and diagnostic information used for network management purposes via UDP port 161 Address Resolution Protocol ARP ARP is used to convert IP addresses to Ethernet addresses ARP requests are sent by the EGX to determine if its address is a duplicate IP address see Duplicate IP Address Detection on page 8 Simple Network Time Protocol SNTP SNTP is a protocol used to synchronize the clocks of networked devices using a NTP server via UDP port 123 Hardware RJ45 Ethernet port Control power RS485 serial port LEDs for Ethernet Power and and serial Status LED communications Bias termination and 2 wire 4 wire jumper switches Reset a button RS232 serial port RJ45 connector 2011 Schneider Electric All Rights Reserved 59 PowerLogic Ethernet Gateway EGX300 63230
103. werden Wenn w hrend des Programmiervorgangs die Stromversorgung unterbrochen wird funktioniert das EGX nicht mehr Die Status LED blinkt w hrend des Programmiervorgangs schnell Wenn das Blinken aufh rt ist die Programmierung abgeschlossen Starten Sie Windows Explorer geben Sie ftp und die IP Adresse des EGX in das Adressentextfeld ein z B ftp 169 254 0 10 und dr cken Sie die Eingabetaste 2 Geben Sie in die Textfelder den Benutzernamen Administrator und das Administratorkennwort ein und klicken Sie auf Anmelden 3 Suchen Sie das Verzeichnis bzw den Ordner in dem die Firmwaredatei egxxxxx bin auf Ihrem Computer gespeichert ist rechtsklicken Sie auf die Datei und klicken Sie dann auf Kopieren 4 Rechtsklicken Sie in das Windows Explorer Fenster und klicken Sie anschlie end auf Einf gen HINWEIS Anstelle von Kopieren und Einf gen k nnen Sie die Datei auch per Drag and Drop in Windows Explorer bertragen 5 Suchen Sie die gespeicherte Aktualisierungsdatei egxxxxx upd auf Ihrem Computer rechtsklicken Sie auf den Dateinamen und klicken Sie dann auf Kopieren 6 Rechtsklicken Sie in das Windows Explorer Fenster und klicken Sie anschlie end auf Einf gen HINWEIS Anstelle von Kopieren und Einf gen k nnen Sie die Datei auch per Drag and Drop in Windows Explorer bertragen 7 Um zu kontrollieren ob die Firmwareversion erfolgreich aktualisiert wurde f hren Sie die Schritte unter
104. where x x x x is the IP address of the EGX HTTP Maximum Used to specify the maximum number of 0 to 65 000 Keepalives HTTP keepalives available Default 100 Modbus TCP IP Server Used to specify the number of Modbus 16 to 64 Connections TCP IP server connections available Default 32 Modbus Broadcast Determines how Modbus TCP IP messages Disabled Enabled or with Unit IDs of O are handled on the serial Enabled with Response subnetwork Disabled all messages are Default Disabled ignored Enabled all messages are treated as broadcasts to serial ports with no response expected Enabled with Response all messages are treated as regular messages to serial ports with a response expected back Modbus TCP Proxy Setting that determines if Modbus TCP IP Disabled or Enabled messages from remote clients will be routed Default Enabled to remote Modbus TCP IP devices that are defined in the EGX Modbus TCP IP Client Amount of time the EGX will wait for a remote 0 1 to 10 Timeout Modbus TCP IP device to respond to a Default 5 seconds Modbus TCP IP request initiated by the EGX Modbus TCP IP Client Amount of time the EGX will wait for a remote 1 to 10 Connection Timeout Modbus TCP IP device to respond to a Default 2 seconds Modbus TCP IP connection request initiated by the EGX Modbus TCP IP Server A timer that closes the Modbus TCP IP 0 to 32 767 seconds Connection Idle Time connection after a specified amount of idle D
105. which options you selected Selects when the data logs are sent in the previous step select the time of day day ofthe week and or the day ofthe month 6 Inthe From Address text box type the e Enters from whom the e mail was sent mail address of the person administering the device NOTE A From e mail address is required because most SMTP servers require it 7 Inthe To Addresses text boxes type the Enters the e mail addresses of the recipients e mail addresses 5 maximum that will be receiving the data logs one address per text box 8 Inthe Server IP Address text boxes enter Enters the address of the server delivering the the address of the outgoing mail server e mail data logs 0 0 0 0 to 255 255 255 255 NOTE Contact your network administrator if you do not know the address of the Simple Mail Transfer Protocol SMTP server 9 In the Server TCP Port text box enter the Enters the outgoing mail server delivery port outgoing mail server delivery port Default 25 10 If the SMTP server requires login Allows you to enter SMTP server login information enable the SMTP server information requires login check box NOTE The EGX supports Plain Login CRAM MD5 and Digest MD5 access authentication 11 If you have checked the SMTP server Records your SMTP server login information requires login check box enter your username and password in the text boxes 12 Click Test E mai
106. wird Details Ausf hrliche Tabelle mit Fern und seriellen Statistiken pro Ger t Serielle Schnittstelle Rahmen gesendet Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen gesendet wird Rahmen empfangen Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen empfangen wird Z hler der sich jedes Mal um eins erh ht wenn eine Nachricht empfangen wird deren CRC nicht mit dem berechneten Wert bereinstimmt Dies ist normalerweise die Folge von Verdrahtungsproblemen Protokollfehler Z hler der sich jedes Mal um eins erh ht wenn eine Nachricht mit einem falschen Format empfangen wird Zeit berschreitungen Z hler der sich jedes Mal um eins erh ht wenn eine Anforderungsnachricht gesendet wird ohne dass eine entsprechende Antwortnachricht innerhalb der zul ssigen Zeit empfangen wird Zeit berschreitungen sind normalerweise das Ergebnis von Konfigurationsfehlern oder einer fehlenden Reaktion des Ger ts Ausnahmen empfangen Z hler der sich jedes Mal um eins erh ht wenn eine Ausnahme empfangen wird Abgegangene Lesenachrichten Z hler der sich jedes Mal um eins erh ht wenn eine Lesenachricht gesendet wird Abgegangene Schreibnachrichten Z hler der sich jedes Mal um eins erh ht wenn eine Schreibnachricht gesendet wird Eingegangene Lesenachrichten Z hler der sich jedes Mal um eins erh ht wenn eine Lesenachricht empfangen wird Eingegangene Schreibnachrichten Z hler der sich jedes Ma
107. zu l schen 4 Klicken Sie auf Protokolleintrag Einblendung der Seite Protokolleintrag hinzuf gen und geben Sie den hinzuf gen in die der Benutzer Wartungstext in das Textfeld Wartungsdetails eingeben kann Eingabedetail ein siehe nachstehende Abbildung 51 um einen neuen Protokolleintrag hinzuzuf gen Abbildung 50 Wartungsprotokoll Wartungsprotokoll Eintr ge l schen Protokoll l schen Protokolleintrag hinzuf gen L schen Datum und Uhrzeit Benutzer Eingabedetail 2010 05 10 14 11 Administrator G Test Abbildung 51 Protokolleintrag hinzuf gen Wartungsprotokoll Datum und Uhrzeit Benutzer Eingabedetail 2009 01 12 16 13 Administrator Die Firmware der EGX Ger te kann mit FTP File Transfer Protocol aktualisiert werden Das neueste Firmware Update finden Sie unter www powerlogic com oder fragen Sie Ihren zust ndigen Vertriebsmitarbeiter danach Das EGX verf gt ber zwei Firmware Komponenten die ausf hrbare Bin rkomponente und die Datei Image Komponente 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Firmware Firmwareversion der ausf hrbaren 1 ffnen Sie den Webbrowser und melden Sie Einblendung der EGX Startseite sich beim EGX an 2 Suchen Sie die Firmwareversion in der Feststellung der Firmware Version des unteren linken Ecke der Seit
108. 0 144 intervals Log File Capacity Maximum Possible Intervals Topics logged per interval Intervals recorded per day 171072 3 144 396 days The logging capacity is dynamically calculated and displayed on the Topic Selection Page see Table 9 for samples Table 9 Sample Recording intervals of Topics Log Capacity in Days for Designated Logging Intervals 5 Min Interval 10 Min Interval 15 Min Interval 594 891 Each device in the device list may be independently enabled for logging Topics to log are unique to each device To view interval data logs see Device Logging on page 40 NOTE To enable the Device Logging feature there must be a time value selected in the Logging Interval drop down window We recommend that you disable the logging feature for the specific device being configured To do this see Figure 13 on page 18 and uncheck the logging check box for the device being selected 17 PowerLogic Ethernet Gateway EGX300 Setup Topics to Log 18 63230 319 216B2 11 2011 1 From the Setup menu click Device Opens the Device Logging page Logging see Figure 13 2 See Figure 13 and check Logging for the Selects the devices to log device s you want to log To select all devices click select all then click Apply To deselect all devices click clear then click Apply 3 Select the Logging Interval Selects the logging interval for the selected devices 4
109. 0 Configuration 14 63230 319 216B2 11 2011 Figure 11 Page Liste des appareils avec connexions distantes prises en charge Liste des appareils Nombre d appareils afficher 8 g Connexion Type d appareil Nom d appareil Identification locale Identification distante Port s rie Modbus Building Main Building West Panel Building East Panel i Building North Panel Port serie g Modbus Port s rie g Modbus Port s rie U Modbus KE E E2 Ez D tection Tableau 7 Param tres de la liste des appareils Nombre d appareils afficher Connexion Type d appareil Nom d appareil Identification locale Identification S lectionne le nombre d appareils 1 64 afficher Par d faut 8 S lectionne le site de connexion Port serie ou adresse IP Par defaut Port serie S lectionne le type d appareil apparaissant Ensemble des appareils pris dans la liste en charge Permet d attribuer un nom chaque appareil Vous devez d finir l identification locale Vous devez d finir l identification distante CS O 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Detection des appareils 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Configuration L option D tection des appareils permet la passerelle EGX de d tecter les appareils Mo
110. 0 02 00 00 CST 2011 Sun Nov 20 03 00 00 CST 2011 Sun Nov 20 03 00 00 CST 2011 Sun Nov 20 04 00 00 CST 2011 Sun Nov 20 04 00 00 CST 2011 Sun Nov 20 05 00 00 CST 2011 Sun Nov 20 05 00 00 CST 2011 Sun Nov 20 06 00 00 CST 2011 Sun Nov 20 06 00 00 CST 2011 Sun Nov 20 07 00 00 CST 2011 Sun Nov 20 07 00 00 CST 2011 Sun Nov 20 08 00 00 CST 2011 002 00 00 009 00 00 47 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Monitoring 11 2011 Getting Dashboard Data Using the Data You can save data from a dashboard in a spreadsheet application as Points Button shown in the steps below Action Result From the dashboard containing desired Displays data points for the selected dashboard data click Data Points Figure 43 on page 47 Press CTRL A then press CTRL C Selects all of the data then copies the data to the clipboard Open Excel then press CTRL V Pastes the data into an Excel spreadsheet Saving a Dashboard To avoid having to select from the main menu each time you access a dashboard use one ofthe methods for saving a dashboard outlined in Table 18 Table 18 Saving a Dashboard Description Browser Bookmark Allows users to access the saved Follow instructions for setting a dashboard on the computer where bookmark in your preferred the bookmark is created browser Documentation Link Allows all EGX users to access a See Documentation Links on saved dashboard from
111. 00 38400 transmission transmission travers une connexion 56000 ou 57600 s rie Par d faut 19200 Parit Permet de s lectionner le type de parit Paire Impaire ou Aucune requise pour v rifier l exactitude des Par d faut Paire donn es l aide d un bit de parit D lai Permet de s lectionner le temps d attente de pendant lequel la passerelle EGX attend Par d faut 3 secondes r ponse une r ponse d un appareil s rie Disponible uniquement si l interface physique et le mode de transmission sont RS 232 Modbus ASCII ATTENTION MAUVAISES PERFORMANCES DU R SEAU Les param tres Ethernet avanc s de la passerelle EGX ne doivent tre modifi s que par des techniciens qualifi s qui ont lu et assimil la documentation relative ces param tres Param tres avanc s du port s rie Le non respect de ces instructions pourrait entra ner une baisse des performances de l interface s rie 1 Cliquez sur Avanc dans la page Port s rie Ouvre la page des param tres avanc s du port s rie 2 Configurez les param tres de port s rie avanc s voir le Permet de d finir les Tableau 6 page 11 pour les options disponibles Cliquez param tres avanc s du port sur Valeurs par d faut pour s lectionner les valeurs par _ s rie d faut pour toutes les options 3 Cliquez sur Appliquer Met jour les param tres avanc s du port s rie de la REMARQUE La modification des do
112. 10 168 253 60 Bestanden In Betrieb Building West Panel CM2000 10 168 253 60 Bestanden In Betrieb Building East Panel CM3000 10 168 253 60 Bestanden In Betrieb Building North Panel PM800 10 168 253 60 Bestanden In Betrieb 2011 Schneider Electric Alle Rechte vorbehalten 55 PowerLogic Ethernet Gateway EGX300 Wartung WARTUNG FIRMWARE Firmwareversion feststellen 56 63230 319 216B2 11 2011 Mit dem Wartungsprotokoll k nnen die Wartungsarbeiten dokumentiert werden die am EGX an den angeschlossenen Ger ten oder an der Anlage zu der das EGX geh rt durchgef hrt werden Jeder Eintrag wird mit Datum und Uhrzeit und dem Namen des betreffenden Benutzers protokolliert Dieses Protokoll listet auch automatisch Systemaktivit ten auf zum Beispiel die Aktivierung bzw Deaktivierung von Funktionen Sie m ssen daf r keine Eintr ge vornehmen Zudem listet dieses Protokoll alle Aktivit ten auf die f r das Wartungsprotokoll auf der Setup Seite Pr fpfad festgelegt wurden siehe Pr fpfad auf Seite 33 e er 1 Klicken Sie im Wartungsmen auf Einblendung der Seite Wartungsprotokoll Wartungsprotokoll 2 Aktivieren Sie das Kontrollk stchen L schen des ausgew hlten Eintrags L schen neben dem Eintrag den Sie l schen m chten Klicken Sie danach auf Eintr ge l schen 3 Klicken Sie auf Protokoll l schen um alle L schen des Wartungsprotokolls Eintr ge im Wartungsprotokoll
113. 10N6200 PM800 Micrologic Sepam Documentation Rendez vous sur le site www powerlogic com et s lectionnez votre pays Localisez la documentation de EGX Logiciel embarque firmware Rendez vous sur le site www powerlogic com et s lectionnez votre pays Localisez les t l chargements EGX pour plus d informations voir Obtention du dernier logiciel embarqu page 57 Passerelle Ethernet PowerLogic EGX300 Acc s la passerelle EGX via un r seau ACC S LA PASSERELLE EGX VIA UN R SEAU Connexion la passerelle EGX 63230 319 216B2 11 2011 Apr s avoir configur les param tres Ethernet de la passerelle EGX voir le manuel d installation EGX vous pouvez acc der la passerelle EGX sur un r seau local Ethernet au moyen d un navigateur Web standard 1 Lancez le navigateur Web Ouvre le navigateur Web 2 Dans la barre d adresses tapez l adresse Ouvre la bo te de dialogue de connexion IP de la passerelle EGX 169 254 0 10 par d faut et appuyez sur Entr e 3 Tapez votre nom d utilisateur Saisit le nom d utilisateur et le mot de passe Administrator par d faut et votre mot de puis ouvre la page d accueil EGX passe Gateway par d faut dans les zones appropri es puis cliquez sur OK REMARQUE Le nom d utilisateur et le mot de passe doivent respecter les majuscules minuscules 4 Cliquez sur l l ment appropri dans la Ouvre l l ment de menu s lectionn barre
114. 11 2011 Schneider Electric All Rights Reserved Pasarela Ethernet EGX300 de PowerLogic Manual del usuario 63230 319 216B2 11 2011 Schneider CATEGORIAS DE RIESGOS Y SIMBOLOS ESPECIALES POR FAVOR TENGA EN CUENTA LO SIGUIENTE DECLARACION DE CLASE A SEGUN LA NORMATIVA DE LA FCC Lea estas instrucciones atentamente y examine el equipo para familiarizarse con el dispositivo antes de instalarlo manipularlo revisarlo o realizar el mantenimiento de este Los siguientes mensajes especiales pueden aparecer a lo largo de este manual o en el equipo para advertir de posibles riesgos o remitirle a otras informaciones que le ayudar n a aclarar o simplificar los procedimientos La adici n de uno de estos dos s mbolos a una etiqueta de seguridad del tipo Peligro o Advertencia indica la existencia de un riesgo de descarga el ctrica que ocasionar lesiones si no se siguen las instrucciones Este es el s mbolo de alerta de seguridad Sirve para alertar de posibles riesgos de lesiones Siga las recomendaciones de todos los mensajes de seguridad precedidos por este s mbolo para evitar posibles lesiones e incluso la muerte PELIGRO PELIGRO indica una situaci n de riesgo inmediato que si no se evita causar la muerte o lesiones graves A ADVERTENCIA ADVERTENCIA indica una situaci n de riesgo potencial que sino se evita puede causar la muerte o lesiones graves APRECAUCION
115. 14 2010 02 11 13 30 48 2010 02 01 00 00 00 Blindleistung k VAR E E 149 2010 02 03 14 37 37 2010 02 01 00 00 00 Scheinleis tung kVA 22 282 345 2010 02 03 14 37 37 2010 02 01 00 00 00 Energie Wirkenergie kWh 2449681 0 2008 01 21 10 56 05 Blindenergie kVARh 1167059 3 2009 01 21 10 58 05 Scheinenergie kVAh 2722891 2 2009 01 21 10 58 05 O 2011 Schneider Electric Alle Rechte vorbehalten 37 PowerLogic Ethernet Gateway EGX300 berwachung Analogmessger tbereich bersichtsger teseiten 38 63230 319 216B2 11 2011 Der Bereich der grafischen Analogmessger te auf der Seite Grundmesswerte kann konfiguriert oder auf automatische Skalierung eingestellt werden siehe Abbildung 31 Aktivieren Sie unter Automatische Skalierung Aktivierung der automatischen aktivieren die Ger te die automatisch skaliert Skalierung f r ausgew hlte Ger te werden sollen HINWEIS Klicken Sie auf Alle ausw hlen um die automatische Skalierung f r alle Ger te zu aktivieren bzw auf L schen um die automatische Skalierung f r alle Ger te zu deaktivieren Geben Sie f r Ger te mit deaktivierter automatischer Festlegung des Messger tbereichs Skalierung die unteren und oberen Grenzwerte f r jeden Messger ttyp ein Abbildung 31 Setup Seite Bereich Min Max Werte Geratebezeichnung Automatische Skalierung aktivieren Laststrom A Leistung L L Spannung L N Spannung Alle ausw hlen L sche
116. 2 Page S lection des appareils S lection des appareils Appareils disponibles Appareils s lectionn s Building Main Building West Panel Building East Panel Building North Panel 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Calcul de tendance 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Figure 33 Page R capitulatif circuit Surveillance Recapitulatif circuit Appareil Courant efficace amp res Puissance active kW Building Main 414 320 Building North Panel 164 130 Pour afficher une tendance en temps r el pour plusieurs appareils et plusieurs grandeurs allez dans le menu Surveillance et s lectionnez Donn es en temps r el gt Calcul de tendance Dans le menu Surveillance s lectionnez Donn es en temps r el S lectionnez Calcul de tendance lectionnez Calcul de tendance en temps r el ectionnez jusqu quatre appareils dans la liste Appareils disponibles S ectionnez une ou plusieurs grandeurs dans la liste D veloppe l arborescence des options de donn es en temps r el D veloppe l arborescence des options de tendance en temps r el Ouvre la page de configuration Calcul de tendance en temps r el Permet de s lectionner les appareils pour le calcul de tendance Permet de s lectionner les des grandeurs disponibles grand
117. 2 Zugriffsberechtigungen f r das EGX 25 Zus tzliche Ressourcen 1 63 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Index 11 2011 64 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Benutzerhandbuch Schneider Electric 295 Tech Park Drive Suite 100 La Vergne TN 37086 USA Technische Unterst tzung Global PMC Tech support schneider electric com 00 1 250 544 3010 Sie erhalten technische Unterst tzung von dem f r Sie zust ndigen Vertriebsmitarbeiter von Schneider Electric oder im Internet unter www schneider electric com PowerLogic ist eine Marke von Schneider Electric Andere verwendete Marken sind das Eigentum ihrer entsprechenden Inhaber Elektrisches Ger t sollte stets von qualifiziertem Personal installiert betrieben und gewartet werden Schneider Electric bernimmt keine Verantwortung f r jegliche Konsequenzen die sich aus der Verwendung dieser Publikation ergeben k nnen 63230 319 216B2 11 2011 ersetzt 63230 319 216B1 mit Datum 08 2011 2011 Schneider Electric Alle Rechte vorbehalten
118. 2011 Configuration Acc s aux pages Web 1 Dans le menu Configuration cliquez sur Acc s aux Ouvre la page Acc s aux pages pages Web Web 2 S lectionnez le niveau d acc s aux pages Web Aucun Voir le Tableau 12 pour une Lecture seule ou Complet de chaque groupe explication des niveaux d acc s d utilisateurs de chaque groupe 3 Pour autoriser le compte Guest acc der la page Web Permet au groupe par d faut s lectionnez Lecture seule sous la colonne Guest Guest d acc der la page Web REMARQUE Si le groupe Guest est en lecture seule les autres groupes peuvent tre configur s uniquement en lecture seule ou en acc s complet 4 Recommencez les tapes 2 et 3 pour r gler les options S lectionne le niveau d acc s de chaque section chaque page Web 5 Cliquez sur Appliquer Enregistre la configuration des mots de passe Tableau 12 Acc s des groupes Acc s complet toutes les pages Web REMARQUE Il est recommand de changer le mot de passe par d faut du compte Administrateur lors de la premi re connexion d acc s sont les suivants Aucun le groupe ne peut pas acc der la page Web s lectionn e Lecture seule le mot de passe autorise l acc s en lecture seule du groupe la page Web s lectionn e Complet le groupe a le m me droit d acc s que le groupe Administrator la page Web s lectionn e Figure 24 Page Acc s aux pages Web Acc s aux pag
119. 30 319 216B2 Configuraci n 11 2011 Figura 11 Pagina Lista de dispositivos con las conexiones remotas admitidas Lista de dispositivos N mero de dispositivos visualizables 8 El Conexi n Tipo de dispositivo Nombre del dispositivo ID local ID remoto Building Main Building West Panel Building East Panel Building North Panel Puerto serie E Modbus y Puerto serie K Modbus Puerto serie 2 Modbus Puerto serie Modbus g Detecci n Tabla 7 Configuraci n de Lista de dispositivos N mero de Selecciona el n mero de dispositivos que De 1 a 64 dispositivos se tienen que mostrar Predeterminado 8 visualizables Conexi n Selecciona el sitio de la conexi n Puerto serie o direcci n IP Predeterminado Puerto serie Tipo de dispositivo Selecciona el tipo de dispositivo que tiene Gama de dispositivos que aparecer en la lista admitidos Nombre del Le permite asignar nombres a dispositivos dispositivo individuales ID local Debe definir el ID local E 14 O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Detecci n de dispositivos Pasarela Ethernet EGX300 de PowerLogic Configuraci n La opci n Detecci n de dispositivos permite a la EGX detectar dispositivos Modbus residentes en el puerto serie que no figuran en Lista de dispositivos Los dispositivos previamente introducidos en Lista de
120. 319 216B2 Appendix B Supported Device Types 11 2011 e supports the following device types This list of supported devices APPENDIX B SUPPORTED The EGX ts the following device t This list of rted devi DEVICE TYPES was accurate at the time this document was published Check www schneider electric com for updates Table 20 EGX300 Supported Device Types Device Group Devices Active Harmonic Filter Accusine Circuit Breakers Compact NSX A Compact NSX E PowerPact A PowerPact E Circuit Monitors CM100 200 CM2000 CM3000 CM4000 ION7500 ION7550 ION7600 ION7650 Digital Meters DM6000 DM6300 Digital Temp Controller Model 98 Drives ATV61 ATV71 Energy Meters Energy Meter Enercept E5600 EM1200 EM26 96 EM6400 EM6433 EM6436 EM6436DUAL EM6438 ION8600 Insulation Monitoring Devices Vigilohm IM20 Vigilohm IM20 H Motor Management TeSys T Multi Circuit Monitors BCPM Model A BCPM Model B BCPM Model C BCM MCM Overload Relays SSOLR MotorLogic Plus MotorLogic Plus II Power Factor Controller Varlogic Power Meters PM9c PM200 PM300 PM500 PM600 PM700 PM800 PM1000 PM5000 ION6200 Standard and Mega ION7300 Protective Relays Sepam 2000 Sepam Series 10 Sepam Series 20 Sepam Series 40 Sepam Series 80 Smart Interface Modules SIM10Z 60
121. 5 2 708 612 190 2 436 138 843 1 160 779 716 14 0 360 02 12 2010 13 50 2 708 637 907 2 436 162 783 1 160 788 984 45 0 360 02 12 2010 13 55 2 708 663 298 2 436 186 450 1 160 798 048 Codes d erreur des journaux de donn es Les codes d erreur ci dessous peuvent apparaitre lorsque vous diagnostiquez les journaux de donn es voir Figure 36 page 41 et Figure 37 page 41 Coce D finition d erreur Erreur de communication par exemple CRC L enregistrement reste activ contr le par redondance cyclique protocole ou moins que le dernier exception intervalle ait t manqu Expiration du d lai d attente en cas de non r ponse L enregistrement reste activ une requ te dans le temps imparti moins que le dernier intervalle n ait t manqu ES Donn es more 100 Expiration de la p riode de scrutation avant que les Intervalle manqu donn es puissent tre enregistr es Contactez le support technique pour obtenir de l aide dans la r solution de ces probl mes ou d autres erreurs Obtention d un journal de donn es Vous pouvez utiliser le protocole FTP pour r cup rer un journal de donn es d intervalle via FTP en vous connectant la passerelle EGX par FTP et en transferant le fichier CSV suivant les instructions ci apr s REMARQUE Si vous souhaitez que la passerelle EGX envoie automatiquement le journal de donn es par FTP les options d exportation du journal de l appareil doivent tre configur
122. 54 0 10 in Anmelden als das Adressentextfeld ein und dr cken Sie die Eingabetaste 2 Geben Sie in die Textfelder den Benutzernamen Er ffnung einer FTP Sitzung mit Administrator und das Administratorkennwort ein und dem EGX klicken Sie auf Anmelden 3 ffnen Sie ein neues Fenster in Windows Explorer Kopiert die Datei in die gehen Sie zur benutzerdefinierten Webseite die Sie an Zwischenablage das EGX senden m chten klicken Sie mit der rechten Maustaste darauf und klicken Sie anschlie end auf Kopieren 4 Wechseln Sie zum EGX Fenster in Windows Explorer ffnet den Ordner in dem die das Sie in Schritt 1 ge ffnet haben und ffnen Sie Webseite auf dem EGX anschlie end den Ordner in den die Webseite kopiert gespeichert wird werden soll z B www monitoring 5 Klicken Sie mit der rechten Maustaste in das rechte Kopiert die benutzerdefinierte Fenster in Windows Explorer und anschlie end auf Webseite in das EGX Einf gen HINWEIS Anstelle von Kopieren und Einf gen k nnen Sie die Datei auch per Drag and Drop in Windows Explorer bertragen 6 Klicken Sie im Windows Explorer Fenster auf Schlie en von Windows Explorer Schlie en Starten Sie Windows Explorer geben Sie ffp und die Einblendung des Dialogfelds IP Adresse des EGX zum Beispiel ftp 169 254 0 10 in Anmelden als das Adressentextfeld ein und bet tigen Sie anschlie end die Eingabetaste 2 Geben Sie in die Textfelder den Benutze
123. 55 Mantenimiento ii Bea 56 A A Identificaci n de la versi n del firmware Versi n del firmware del componente binario ejecutable Versi n del firmware del componente de imagen de archivo 57 Obtenci n de firmware NUEVO oocccoccccccccnooonccnnononnnnnnnnnnnnnnnnnnnnnnnnn cnn nc cananea 57 Actualizaci n del firmware ooooonoccccnnnniccccnccccnnnonncnnnnnnn cnn ncnnnnn nn nn cnn nnnnnnnnnns 58 Ap ndice A Protocolos Ethernet compatibles ooccococccicocicocanonononnnnon 59 Equipoifisich Horaria io ann its eek 59 Ap ndice B Tipos de dispositivos admitidos 60 ii 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 INTRODUCCION Otros recursos 2011 Schneider Electric Reservados todos los derechos Pasarela Ethernet EGX300 de PowerLogic Introduccion La EGX300 es un dispositivo basado en Ethernet que proporciona una interfaz transparente entre redes basadas en Ethernet y dispositivos que pueden ser instalados por el usuario Entre estos ultimos se incluyen medidores monitores rel s protectores aut matas programables PLC unidades de control controles de motores y otros dispositivos que se comunican mediante protocolos Modbus Jbus o PowerLogic La EGX300 utiliza el protocolo Modbus TCP IP para acceder a informaci n de dispositivos que puede instalar el usuario a trav s de una red de rea local LAN o a trav s de una red
124. 58 mise jour par ftp 56 obtention de la derni re version 57 mat riel 59 N niveaux d acc s l EGX 25 P page Documentation 49 pages d appareil unique 37 41 pages recapitulatives appareils 38 45 Passerelle Ethernet PowerLogic EGX300 Index pages Web ajout suppression dans l interface Web 31 configuration 29 personnalisation 30 parametres de port serie avances 9 des mesures de base 37 Ethernet avances 6 Ethernet et TCP IP 5 SNMP configuration 25 TCP IP 5 piste d audit 33 journal de maintenance 34 section Syslog 34 plage des cadrans analogiques 38 point d acc s systeme configuration 35 liens d autres passerelles EGX300 48 pr f rences personnalisation de l EGX 32 prise en charge des types d appareil 60 protocoles Ethernet 59 pris en charge 59 R registres d appareils lecture 54 requ te Web Microsoft journal de donn es d intervalle 44 r seau acc s via 2 ressources suppl mentaires 1 S s curit du mot de passe indication couleur 28 statistiques 50 interpretation 51 surveillance 37 synchronisation de l heure r seau 24 Syslog pistes d audit 34 T tableaux de bord 46 types d appareils affichables 33 pris en charge 60 V v rification des communications 55 automatique 55 manuel 55 version du composant binaire ex cutable du logiciel embarqu 57 version du composant image de fichier de logiciel embarqu 57 63 Passerelle Ethernet PowerLogic EG
125. 63230 319 216B2 11 2011 1 En la p gina web Registro de dispositivos Abre una nueva ventana en la que se muestran consulte la Figura 36 haga clic en los datos registrados Puntos de datos 2 Pulse CTRL A y luego pulse CTRL C Selecciona todos los datos y luego copia los datos en el portapapeles 3 Inicie Excel y luego pulse CTRL V Pega los datos en una hoja de c lculo de Excel 1 Inicie el explorador web Abre el explorador web 2 Verifique que el archivo de registro est Abre la p gina de registros de datos disponible escribiendo la direcci n IP de la EGX300 seguida de Istream devlog_data html device x donde x es el ID local del dispositivo 3 Inicie Excel y haga clic en Datos gt Abre el cuadro de di logo Nueva consulta Importar datos externos gt Nueva Web de Excel consulta Web NOTA Esta ruta de acceso es t pica de Microsoft Excel 2003 4 En el cuadro de di logo Nueva consulta Abre el archivo del registro de datos Web escriba la direcci n del registro introducido en el paso 2 y luego haga clic en Ir 5 Haga clic en la flecha m s exterior para Selecciona los datos y luego abre el cuadro de seleccionar todos los datos y luego haga di logo Importar datos clic en Importar 6 Haga clic en Aceptar Importa los datos NOTA Si desea mostrar los datos m s recientes cada vez que abra la hoja de c lculo haga clic en Propiedades en el cuadro de di logo Importar datos y seleccione
126. 63230 319 216B2 11 2011 Ger teprotokollexport E Mail Export 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Abbildung 14 Gr enauswahlseite Ger tebezeichnung Building North Panel PM800 Alle au a Themenbezeichnung Y Scheinenergie KVAh Wirkenergie kWh Blindenergie kVARh Gesamtscheinleistung kVA EE Gesamtwirkleistung kW Gesamtblindleistung KVAR Mw Wirkleist kW Mw Blindleist KVAR Strommittelwert L1 u Je ee Strommittelwert L2 Strommittelwert L3 Strommittelwert L1 letztes Strommittelwert L2 letztes Strommittelwert L3 letztes Strom L1 Strom L2 Strom L3 Strom Durchschnitt Spannung 1 2 Spannung 2 3 Ele ee 1 I Spannung 3 1 Spannung L L Durchschnitt Spannung 1 N Spannung 2 N Spannung 3 N DO OD Spannung L N Durchschnitt Standardwerte bernehmen Setup 3 Aktiviert Intervalle 57024 Tage 594 Aufzeichnungsintervall 15 minuten Mit dieser Option k nnen Sie Ger teprotokolle auf dreierlei Art exportieren ber E Mail FTP oder HTTP In den folgenden Abschnitten werden beide Methoden beschrieben HINWEIS Wenn sich die E Mail FTP oder HTTP Server nicht auf demselben Ethernet Netzsegment wie das EGX befinden muss das EGX Standard Gateway ordnungsgem konfiguriert sein Siehe Ethernet und TCP IP Einstellungen auf Seite 5 1 Klicken Sie au
127. 86 2009 08 10 12 56 20 2009 05 28 15 41 15 lb 35 347 782 2008 08 04 13 53 53 2009 05 28 15 41 15 Ic 331 332 801 2008 08 10 12 57 05 2009 05 28 15 41 15 Demand Power Real kW 208 200 314 2010 02 11 13 30 48 2010 02 01 00 00 00 Reactive kKVAR 8 EJ 149 2010 02 03 14 37 37 2010 02 01 00 00 00 Apparent kVA 24 24 245 2010 02 03 14 37 37 2010 02 01 00 00 00 Energy Real Energy kWh 2449871 0 2009 01 21 10 58 05 Reactive Energy kVARh 1167055 8 2009 01 21 10 58 05 Apparent Energy kVAh 2722580 8 2009 01 21 10 56 05 2011 Schneider Electric All Rights Reserved 37 PowerLogic Ethernet Gateway EGX300 Monitoring Analog Gauge Range Summary Device Pages 38 63230 319 216B2 11 2011 The range of the Graphic Analog Gauges on the Basic Readings page may be configured or set to scale automatically Figure 31 Under Enable Auto Scale check the Enables auto scale for selected devices devices you wish the gauges to auto scale NOTE Click Select All to enable auto scale for all devices and Clear to disable auto scale for all devices For devices with auto scale disabled enter Set gauge range the Min and Max limits for each gauge type 3 Click Apply Updates the Auto Scale settings Figure 31 Range Setup Page Min Max Ratings Device Name Enable Auto Scale Load Current A Power Voltage LL Voltage LN select all clear Min Max Min Max Min Max Min Max
128. A Ana Heise Sincronizaci n horaria de red Par metros del SNMP sernai eee dean Filtrado de Modbus TCP IP V nculos de documentaci n uusrsnneeessnnnnennnnnnnnnnnnnnnnnn nennen ernennen nenn Cu ent s de us ano 2 2 RB Acceso a p gina Web uuuneennenenennnnnenennnnnnn Agregar o quitar paginas web personalizadas Adici n de paginas web mediante FTP Eliminaci n de p ginas web mediante FTP Agregar o quitar paginas web a o de la interfaz web Preferencia ici Tipos de dispositivos visualizables ooocconnnnnnnicionncicnonocannocccnnnrrncnnnarnrnnnn Historial de auditoria u en ee ae Punto de acceso del sistema u 422uusrsnnneessnnnnnnnnen nenne nnnnnnnnnner ernennen Supervisioni 2 2 32 2 armani Datos en tiempo Teal arten P ginas de dispositivo nico Configuraci n de lecturas b sicas Rango de los indicadores anal gicos rererere P ginas de resumen de dispositivos Tendencias Registro de dispositivos Paginas de dispositivo Unico Obtenci n de registros cronol gicos de datos nn Formato de registro cccccceeceecceceeeeeeeeaeeceeesenaeeeeeeeeeeneeeeees C digos de error para los registros cronol gicos de datos 2011 Schneider Electric Reservados todos los derechos i Pasarela Ethernet EGX300 de PowerLogic
129. A TRAV S DE UNA RED Inicio de sesi n en la EGX 63230 319 216B2 11 2011 Una vez que haya configurado los par metros de Ethernet de la EGX consulte el manual de instalaci n de esta podr acceder a la EGX a trav s de una LAN Ethernet utilizando cualquier explorador web 1 Inicie el explorador web Abre el explorador web 2 En la barra de direcciones escriba la Abre el cuadro de di logo Iniciar sesi n direcci n de la EGX la direcci n predeterminada es 169 254 0 10 y a continuaci n pulse Intro 3 Escriba su nombre de usuario Introduce el nombre de usuario y la contrase a Administrator es el valor predeterminado y a continuaci n abre la p gina de inicio de y la contrase a Gateway es la la EGX predeterminada en los cuadros de texto y despu s haga clic en Aceptar NOTA El nombre de usuario y la contrase a respetan may sculas y min sculas 4 Haga clic en el elemento correspondiente Abre el elemento de men seleccionado de la barra de men s Figura 2 P gina de inicio de la EGX PowerLogic EGX300 Documentaci n Schneider Electric Inicio Barra de men s Versi n del firmware 4 000 Copyright 2005 2011 Schneider Electric Todos los derechos reservados Usuario Le aconsejamos que se desconecte cuando no necesite acceder a la EGX Para salir de la sesi n de la EGX haga clic en Desconexi n o cierre el explorador O 2011 Schneider Electric Rese
130. Building Main Y o 100 100 100 o 100 0 100 Building West Panel Y 0 100 100 100 0 100 0 100 Building East Panel Y o 100 100 100 o 100 0 100 Building North Panel Y o 100 100 100 o 100 0 100 Apply The Summary Device table views provide summaries of one or more selected devices 1 From the Monitoring menu click Summary Device Expands tree for summary page Pages selection choices 2 Select which summary page you want to view Opens the device selection list 3 Select a device s from the Available Devices list Selects a device s for the summary then click Next see Figure 32 options NOTE Click gt gt to select all available devices Figure 32 Device Selection Page Device Selection Available Devices Selected Devices Building Main Building West Panel Building East Panel Building North Panel Next 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Trending 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Monitoring Figure 33 Circuit Summary Page Circuit Summary 2011 07 20 14 05 19 294 320 New Device s _ Device RMS Current Amps Real Power kW Power Factor Breaker Device 3 1031 346 98 4 0 260 lead Device 4 41 026 5 8 0 398 lead To view a real time trend of multiple devices and topics go to the Monitoring Menu and select Real Tim
131. Click Apply Updates the EGX Device Logging settings To customize logging content enable device Selects the device topics to be logged then logging then do the following returns to the main Device Logging page Select a logging interval other than zero NOTE If you change the default topics and uncheck the specific device logging logged for a device an asterisk appears selection checkbox next to topics in the Customize column for f i i that device Changing the topics of a device i Pip topics under an for the log that has already been active will clear all ENIGE YOR Manto COMM ess previously logged data for that device If See Figure 14 and check the topics you needed the data should be retrieved from want to log the EGX prior to the changes To select all topics click select all then click Apply To deselect all topics click clear then click Apply To select the default topics click Defaults at the bottom of the screen To delete a data log check Purge Data for the Selects the data logs to purge one s you want to delete NOTE To purge a data log the device must 1 To select all devices click select all then not have the Logging check box enabled click Apply 2 To deselect all devices click clear then click Apply To disable logging select a logging interval of Turns off the logging feature zero ensure the logging selections are unchecked then click Apply Figure 13 Device Logging Page
132. Escriba la contrase a que requiera el servidor SMTP m x 31 caracteres Marque los tipos de informe cuyos mensajes desee reenviar Haga clic en Aplicar o Predeterminados O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuracion Figura 28 Configuraci n de Historial de auditoria Historial de auditoria Registro de mantenimiento Informe Error del sistema Error de seguridad Configuraci n O Informativos Syslog Direcci n IP del servidor 0 0 0 0 Puerto UDP del servidor 514 1 65535 Instalaci n Gravedad E Emores 3 Informe Error del sistema Local0 16 Error de seguridad Auth 4 Advertencias 4 Notificaciones 5 BA E E E E P O Configuraci n Local 16 i Informativos Local0 16 Informativos 6 Correo electr nico Desde direcci n A direcciones fo Direcci n IP del servidor O D 10 Puerto TCP del servidor 25 1 65535 El servidor SMTP requiere iniciar sesi n Nombre de usuario Contrase a Informe Error del sistema Error de seguridad Configuraci n Informativos Predeterminados Aplicar Punto de acceso del sistema El punto de acceso del sistema proporciona un medio de detectar otros dispositivos Schneider Elec
133. Espace libre 243918 KOctets 99 R initialiser 50 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Interpretation des statistiques 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Diagnostics Etat de liaison Cha ne de caract res qui repr sente la vitesse de transmission et le param tre duplex utilis s pour communiquer avec un autre appareil Trames transmises avec succ s Compteur qui augmente d une unit chaque fois qu une trame est envoy e sans probl me Collisions Compteur qui augmente d une unit chaque fois qu une trame est retransmise cause de la d tection d une collision Exc s de collisions Compteur qui augmente d une unit chaque fois qu il est impossible d envoyer une trame car le nombre maximal de collisions bas sur l algorithme de repli exponentiel binaire par troncature est atteint Trames re ues avec succ s Compteur qui augmente d une unit chaque fois qu une trame est re ue sans probl me Erreurs CRC Compteur qui augmente d une unit chaque r ception d une trame dont la somme de contr le CRC contr le par redondance cyclique ne pond pas la valeur calcul e Erreurs d alignement eur qui augmente d une unit chaque ion d une trame dont la somme de contr le contr le par redondance cyclique est erron e ine se termine pas sur une limite sur 8 bits Longueur de trame excessive eur qui a
134. FTP Tiempo de inactividad de conexi n HTTP N mero de puerto HTTP N mero de puerto HTTPS Maximo de mantenimientos de conexiones HTTP Conexiones servidor Modbus TCP IP Difusi n Modbus Proxy MODBUS TCP Tiempo de espera de cliente Modbus TCP IP Tiempo de espera de conexi n de cliente Modbus TCP IP Tiempo de inactividad de conexi n de servidor Modbus TCP IP 2011 Schneider Electric Reservados todos los derechos Identifica el numero de routers pasarelas que puede pasar un paquete TCP Un temporizador que detecta cuando un dispositivo conectado o una conexi n inactiva pasa a no estar disponible debido a eventos tales como un reinicio o apagado El valor de 0 deshabilita esta opci n Se utiliza para especificar durante cuanto tiempo esperara la EGX a que un servidor BootP asigne sus direcciones IP La direcci n IP predeterminada se utiliza despu s del tiempo de espera si no se ha asignado ninguna direcci n IP Se utiliza para especificar durante cuanto tiempo se mantendr n las entradas de la tabla ARP Protocolo de resoluci n de direcciones Controla si se inicializa el servidor FTP durante el arranque Un temporizador que cierra la conexi n FTP despu s de una cantidad especifica de tiempo de inactividad Un temporizador que cierra la conexi n HTTP despu s de una cantidad especifica de tiempo de inactividad El puerto TCP utilizado para los mensajes HTTP Los siguient
135. GX Web pages assigned by the EGX administrator NOTE There are two default user accounts Administrator the default password is Gateway and Guest the default password is Guest 1 From the Setup menu click User Accounts Opens the User Accounts page 2 If you want to change a group name type a Enters a new group name new name in one ofthe Groups text boxes the Administrator group name cannot be changed 3 Inthe Users section enter a Name 1 to 24 Enters the name and password for a user characters and Password 0 to 12 characters for a new user The EGX300 checks the strength of the password displaying both a color and textual indication of strength Blank Password Weak Password Medium Strength Password Strong Password Very Strong Password 4 Select a group and the default language for Selects the group and language for a user the new user 5 Repeat steps 3 and 4 for each additional Continues adding users user you want to add 6 Click Apply Saves all of the user account settings NOTE User names and passwords are case sensitive and can contain only alphanumeric characters Table 11 EGX accounts and passwords User defined accounts up to 11 accounts possible No default Password is user defined Figure 23 User Accounts Page User Accounts Groups Administrators Engineering Operations Maintenance Users Name Password Group Language AAA Engineering z Engisn
136. GX en kilobytes Espacio libre La cantidad total de espacio de disco no utilizado en el disco de la EGX en kilobytes 2011 Schneider Electric Reservados todos los derechos 53 Pasarela Ethernet EGX300 de PowerLogic Diagn sticos Lectura de registros de dispositivo 54 63230 319 216B2 11 2011 Esta opci n permite a la EGX leer desde sus dispositivos locales o remotos Figura 48 P gina Lectura de registros de dispositivo Lectura de registros de dispositivo Nombre del dispositivo ID local Registro de inicio Numero de registros Seleccione por ID de dispositivo y 1 1000 10 Registro Valor Tipo datos Registros de retenci n M Decimal O Hexadecimal O Binario O ASCII 1 En el men Diagn sticos haga clic en Abre la p gina Lectura de registros de dispositivo Lectura de registros de dispositivo 2 Introduzca el ID local del dispositivo o Introduce los registros que se deben leer elijalo en la lista de dispositivos definidos desde el dispositivo especificado la direcci n datos de comienzo y el n mero de registros que se deben leer 3 Seleccione un tipo de datos Selecciona el tipo de datos apropiado 4 Para modificar la visualizaci n de los datos Selecciona el modo de visualizaci n de los de la columna Valor seleccione Decimal valores de los datos Hexadecimal Binario o ASCII 5 Haga clic en Lectura Lee los registros del dispositivo seg n
137. Importer des donn es puis s lectionnez Actualiser louverture du fichier La passerelle EGX doit amp tre configur e de mani re a envoyer des journaux a une adresse lectronique Pour plus d informations voir Exportation par courrier lectronique page 19 La passerelle EGX doit tre configur e de mani re a envoyer des journaux un serveur Web Pour plus d informations voir Exportation par HTTP page 22 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Surveillance Pages r capitulatives appareils Les vues Pages r capitulatives appareils affichent des r capitulatifs concernant un appareil ou une s lection d appareils 1 Dans le menu Surveillance cliquez sur D veloppe l arborescence des options Journaux d appareil Journaux d appareil disponibles 2 Sous Journaux d appareil cliquez sur Pages r capitulatives appareils 3 Sous Pages r capitulatives appareils Ouvre la page de configuration Plusieurs cliquez sur Plusieurs appareils une appareils une seule grandeur seule grandeur 4 S lectionnez un appareil dans la liste Permet de s lectionner les appareils pour les Appareils disponibles options de r capitulatif REMARQUE Vous pouvez s lectionner jusqu a 4 appareils 5 S lectionnez une grandeur dans la liste Permet de s lectionner la grandeur a afficher Grandeurs disponibles pour chaque p rip
138. M S S lo lectura m Ninguna Carbon Footprint S lo lectura S lo lectura w S lo lectura y Ninguna v Carbon Footprint S lo lectura W S lo lectura pm S lo lectura ly Ninguna M Agregar o quitar paginas Web O 2011 Schneider Electric Reservados todos los derechos 29 Pasarela Ethernet EGX300 de PowerLogic M Configuraci n Agregar o quitar p ginas web personalizadas Adici n de p ginas web mediante FTP Eliminaci n de p ginas web mediante FTP 30 63230 319 216B2 11 2011 Las p ginas web personalizadas y otros tipos de archivos pueden transferirse desde su equipo a la EGX a trav s de FTP Los archivos enviados a trav s de FTP a los directorios www monitoring supervisi n www maintenance mantenimiento o www control con extensiones htm html o shtml se asegurar n autom ticamente Cada carpeta cuenta con un v nculo correspondiente en la barra de men s de la interfaz web Cuando se hace clic en el v nculo de la barra de men s las p ginas web que haya agregado aparecer n en el men en la parte izquierda de la ventana del navegador bajo P ginas personalizadas NOTA No se pueden crear nuevas carpetas dentro de las carpetas Monitoring Control o Maintenance Una vez que se hayan transferido las p ginas web personalizadas u otros archivos a la EGX con FTP se pueden agregar y quitar de la interfaz web sin eliminarlos de la EGX usando la p gina Agregar o quitar p ginas Web E
139. Mal um eins erh ht wenn eine Datei nicht gesendet werden kann weil das EGX den Vorgang nicht einleiten kann er der sich jedes Mal um eins erh ht wenn eine ail erfolgreich an den SMTP Server gesendet wird Z hler der sich jedes Mal um eins erh ht wenn das EGX keine Verbindung zum SMTP Server herstellen kann Z hler der sich jedes Mal um eins erh ht wenn der SMTP Server den Benutzernamen bzw das Kennwort t authentifizieren kann er der sich jedes Mal um eins erh ht wenn eine ail nicht an den SMTP Server gesendet werden kann er der sich jedes Mal um eins erh ht wenn das Erstellen einer E Mail durch das EGX fehlschl gt und die E Mail nicht gesendet werden kann 53 PowerLogic Ethernet Gateway EGX300 Diagnose Ger teregister lesen 54 63230 319 216B2 11 2011 Diese Option erm glicht es angeschlossene lokale und entfernte Ger te mit dem EGX auszulesen Abbildung 48 Seite Ger teregister lesen Ger teregister lesen Ger tebezeichnung Lokale ID Startregister Anzahl Register Auswahl nach Ger te ID x 1 1000 10 Register Wert Datentyp Halteregister x Dezimal Hexadezimal O Bin r O ASCII RS EN SE 1 Klicken Sie im Diagnose Men auf Einblendung der Seite Ger teregister lesen Ger teregister lesen 2 Geben Sie die lokale Ger te ID ein oder Eingabe der vom angegebenen Ger t zu w hlen Sie sie aus der definierten les
140. N Spannung f r die Anzeige in der grafischen Darstellung des Analogmessger ts aus Auswahl der Gr en die in der grafischen Darstellung des Analogmessgerats angezeigt werden sollen HINWEIS Analogmessger tdar stellungen stehen nicht f r alle Ger tetypen zur Verf gung Standardm ig passen die Messger te ihren Anzeigebereich automatisch an W hlen Sie Bereich aus wenn ein fester Bereich gew nscht wird Anweisungen f r die Konfiguration des Bereichs der Analogmessger te sind in der nachstehenden Tabelle aufgef hrt Steuerung des Anzeigebereichs der Analogmessger te Grundmesswerte Building Main CM4000 2010 02 15 12 43 07 o r A Ci Bereich 200 200 1 00 100 o Pe o 336 12 A 324 13 A Laststrom 4 11 185 315 290 12 188 336 3 13 186 24 331 Durchschnitt 186 25 383 Empfangen o 2 29 la Leistung Wirk leis tung kw 143 258 200 Blindlsistung k VAR a 125 Scheinleistung kVA 158 274 229 Gesamtlei stung sfaktor 0 849 nacheilend 0 943 nacheilend 0 948 nacheilend Spannung u12 483 494 u22 5 488 42 u31 485 430 42 UL L Durchschnitt 483 487 497 u1 z7 280 285 u2 278 280 288 u2 281 284 289 UL N Durchschnitt 279 281 287 Frequenz Hz 59 60 01 60 06 Strommittelwert A m 22 223 788 2009 08 10 12 58 30 2009 05 28 15 41 15 12 345 345 782 2009 08 04 13 53 53 2008 05 28 15 41 15 13 331 31 801 2003 08 10 12 57 05 2009 05 28 15 41 15 Leistungsmittelwert Wirk leistung kW 25 25 3
141. P du serveur 0 0 0 0 Port TCP du serveur 21 Repertoire Nom d utilisateur user Mot de passe s Passif Exportation manuelle Test FTP Appliquer REMARQUE Si l acheminement est r gl sur les options Horaire ou Intervalle d enregistrement la case cocher Incr mentale est automatiquement s lectionn e 2011 Schneider Electric Tous droits r serv s 21 Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Configuration 11 2011 Exportation par HTTP 1 Dans la page Configuration cliquez sur Ouvre la page Exporter le journal de l appareil Exporter le journal de l appareil 2 Selectionnez HTTP comme mode Affiche les options d exportation des journaux d acheminement d appareil par HTTP 3 Cochez l option Incr mentale Permet de s lectionner uniquement les REMARQUE Si l acheminement est r gl moe nn a depuis la sur les options Horaire ou Intervalle SLDIETESXPOMANON ES DONNEESTEUSSIE d enregistrement la case cocher Incr mentale est automatiquement s lectionn e REMARQUE Si l option Incr mentale est d sactiv e la totalit du fichier journal est envoy e par HTTP chaque intervalle d fini S lectionnez Horaire Quotidien Permet de s lectionner la fr quence Hebdomadaire Mensuel ou Intervalle d acheminement des journaux de donn es d enregistrement Selon les options sp cifi es
142. PowerLogic Ethernet Gateway EGX300 User Guide 63230 319 216B2 11 2011 Schneider HAZARD CATEGORIES AND SPECIAL SYMBOLS PLEASE NOTE CLASS A FCC STATEMENT _0 gt A Read these instructions carefully and look at the equipment to become familiar with the device before trying to install operate service or maintain it The following special messages may appear throughout this bulletin or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure The addition of either symbol to a Danger or Warning safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death A DANGER DANGER indicates an imminently hazardous situation which if notavoided will result in death or serious injury A WARNING WARNING indicates a potentially hazardous situation which if not avoided can result in death or serious injury A CAUTION CAUTION indicates a potentially hazardous situation which if not avoided can result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided can
143. R DANGER indique une situation de danger imminent qui si elle n est pas vit e entrainera la mort ou des blessures graves A AVERTISSEMENT AVERTISSEMENT indique un danger potentiel qui s il n est pas vit peut entra ner la mort ou des blessures graves ATTENTION ATTENTION indique un danger potentiel qui s il n est pas vit peut entra ner des blessures l g res ou de gravit moyenne ATTENTION ATTENTION utilis sans le symbole d alerte de s curit indique une situation de danger potentiel qui si elle n est pas vit e peut entra ner des dommages mat riels REMARQUE Fournit des renseignements compl mentaires pour clarifier ou simplifier une proc dure Seul un personnel qualifi doit effectuer l installation l utilisation l entretien et la maintenance du mat riel lectrique Schneider Electric n assume aucune responsabilit des cons quences ventuelles d coulant de l utilisation de cette documentation Cet appareil a subi des essais et a t reconnu conforme aux limites impos es aux appareils num riques de classe selon le paragraphe 15 de la r glementation FCC Commission f d rale des communications des tats Unis Ces limites sont con ues pour fournir une protection raisonnable contre les interf rences nuisibles lorsqu un appareil est employ dans un environnement commercial Cet appareil produit utilise et peut mettre de l
144. Schneider au aa QU P Electric Accueil Documentation D connexion greso atenas Gomgurton La passerelle EGX peut ex cuter manuellement une ou plusieurs commandes de r initialisation pr d finies pour chaque type d appareil Depuis le menu Commande cliquez sur Ouvre la page R initialisations R initialisations 2 S lectionnez l appareil afficher ou S lectionne l appareil et affiche les options de r initialiser dans la liste R initialisations r initialisation correspondantes avec la date et l heure de la derni re r initialisation 3 S lectionnez les param tres de l appareil S lectionne la r initialisation effectuer sur que vous voulez r initialiser l appareil s lectionn 4 Cliquez sur R initialiser Envoie l appareil s lectionn une ou plusieurs commandes de r initialisation pour la ou les op rations souhait es et en affiche l tat Figure 46 R initialisations Reinitialisations Building 1 Feeder 1 Sub panel A Param tre Datelheure de la derni re r initialisation tat Min Max _ pa Maximum de valeur moyenne ooo nergie accumul e R initialiser REMARQUE Le param tre Date Heure indique la date et l heure actuelles de l appareil s lectionn Si vous choisissez de r initialiser ce param tre la date et l heure de la passerelle EGX seront envoy es l appareil Les valeurs de date et d heure ne sont rapport es que s
145. Topologie serielle Slave und entfernte Ger te Ethernet Verbindung EGX300 Webseiten IP Adresse des EGX100 169 254 0 28 IP Adresse des EGX300 u 169 254 0 75 u BEN E EAS er ae RS485 Es sind bis zu 16 IP Verbindung Fernverbindungen m glich RS485 Verbindung a c 7 pa 7 nd I Im ulm ml Entfernte Slave Ger te Serielle Slave Ger te 3 12 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Ger teliste einrichten PowerLogic Ethernet Gateway EGX300 Setup Klicken Sie im Setup Men auf Einblendung der Seite Ger teliste Ger teliste Abbildung 10 zeigt lokale Verbindungen und Abbildung 11 zeigt entfernte Verbindungen sofern verf gbar 2 F rdie Suche nach lokal angeschlossenen Einblendung der Seite Ger teerkennung f r Ger ten k nnen Sie Erkennung die Erkennung aller lokal angeschlossenen verwenden siehe Ger teerkennung auf Ger te Seite 15 Wenn die Konfiguration entfernter Ger te erforderlich ist fahren Sie mit Schritt 3 fort 3 Beachten Sie Abbildung 11 auf Seite 14 Auswahl der Anzahl sichtbarer Standorte die und w hlen Sie die Anzahl der zur Definition der an das EGX angeschlos anzeigbaren Ger te aus 1 bis 64 senen Ger te benutzt werden k nnen 4 W hlen Sie die Verbindung aus der Auswahl der Verbindung Dropdown Liste aus
146. U Jbus y PowerLogic SY MAX en el mismo bus de comunicaciones serie 2400 4800 9600 19200 38400 56000 o 57600 Predeterminado 19200 Par Impar o Ninguna Predeterminado Par 0 1 a 10 segundos Predeterminado 3 segundos S lo est disponible si la interfaz f sica y el modo de transmisi n son RS232 Modbus ASCII Configuraci n avanzada del puerto serie PRECAUCI N RENDIMIENTO REDUCIDO DE LA RED Solo los trabajadores cualificados deben cambiar la configuraci n avanzada del puerto serie de la EGX Tales modificaciones deben realizarse solo despu s de leer acerca de la configuraci n avanzada del puerto serie y comprenderla El incumplimiento de estas instrucciones puede reducir el rendimiento de las comunicaciones serie 1 Haga clic en Avanzado en la p gina Puerto serie Abre la p gina Configuraci n avanzada del puerto serie 2 Configure los par metros avanzados del puerto serie para ver las opciones disponibles consulte la Tabla 6 en la Configura los par metros avanzados del puerto serie p gina 11 Haga clic en Predeterminados para asignar los valores predeterminados a todas las opciones Haga clic en Aplicar NOTA Al aplicar los cambios a la p gina Configuraci n avanzada del puerto serie no se guardan los cambios en la p gina Puerto serie Figura 6 Actualiza la configuraci n avanzada del puerto serie de la EGX P gina Configuraci n avanzada del puert
147. Verbindungsfehler Authentifizierungsfehler Sendefehler Allgemeiner Fehler FTP Client Authentifizierungsfehler Verzeichnisfehler Sendefehler Allgemeiner Fehler Authentifizierungsfehler Sendefehler Allgemeiner Fehler Dateisystem Kapazit t insgesamt Freie Kapazit t er der sich jedes Mal um eins erh ht wenn eine Datei greich an den HTTP Server gesendet wird Z hler der sich jedes Mal um eins erh ht wenn das EGX keine Verbindung zum HTTP Server herstellen kann Z hler der sich jedes Mal um eins erh ht wenn der HTTP Server den Benutzernamen bzw das Kennwort nicht authentifizieren kann er der sich jedes Mal um eins erh ht wenn eine Datei t zum HTTP Server gesendet werden kann Z hler der sich jedes Mal um eins erh ht wenn eine Datei nicht gesendet werden kann weil das EGX den Vorgang nicht einleiten kann Z hler der sich nach jeder erfolgreichen bertragung an einen FTP Server um eins erh ht Z hler der sich jedes Mal um eins erh ht wenn das EGX keine Verbindung zum FTP Server herstellen kann Z hler der sich jedes Mal um eins erh ht wenn der FTP Server den Benutzernamen bzw das Kennwort nicht authentifizieren kann Z hler der sich jedes Mal um eins erh ht wenn der FTP Server das angeforderte Verzeichnis nicht lokalisieren kann er der sich jedes Mal um eins erh ht wenn eine Datei t zum FTP Server gesendet werden kann Z hler der sich jedes
148. Webseiten mit FTP 30 L schen von Webseiten mit FTP 30 Webseiten zur Webschnittstelle hinzuf gen oder aus ihr entfernen 31 Pr ferenzen are ee en rl Sd eher enter Beeren spe tn 32 Anzeigbare Ger tetypen siennes dires 33 A ee mon ren nn Bine 33 Systemzugangspunkt u see ss 35 berwachung hs dai 37 Echt eitdatei sarsii piore a a nee 37 Ei nzelgerates ten iinit ae eeraa iai aaae ia aiat 37 Grundmesswerteinstellungen o oooccnccccnnonocinnoncnnnnonnnnnrn corno nc nnnnonnnnnnnnn 37 Analogmessgeratbereich oooonncnnnnccnnnicccnnncnnnnonncnnnonnc nenne nennen nennen rn 38 bersichtsger teseiten c ccccccecsecsssceecseeecsctecsessesessesetseeecsesessesecens 38 Trendy rfolgung ci t at ei 39 Ger teaufzeichnung su 40 Einzelger teseiten tauni a a a aa e aaa a 41 Abrufen eines Datenprotokolls 2 0 0 2 cccccceeeeeeeceeeceeeeeeeeeeeeeeeaeeeeeetees 42 Protokollf rmat 4 nent eee 42 Fehlercodes f r Datenprotokolle u 224444444r nn nn nennen nnnnnnnnnnnn nn 43 2011 Schneider Electric Alle Rechte vorbehalten i PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Inhaltsverzeichnis 11 2011 Abrufen eines Intervalldatenprotokolls mit FTP u 43 Abrufen eines Intervalldatenprotokolls mit der Schaltfl che D tenp nkte nr ana 44 Abrufen eines Intervalldatenprotokolls mit Microsoft WebQuery 44 Abrufen eines Intervalldatenprotokolls ber E Mail
149. X 4 Haga clic en Aplicar Agrega una p gina web personalizada a la interfaz web de la EGX o la quita de esta Figura 25 Pagina Agregar o quitar paginas Web Agregar o quitar paginas Web Supervision Control Mantenimiento device shtml KI 2011 Schneider Electric Reservados todos los derechos 31 Pasarela Ethernet EGX300 de PowerLogic M Configuraci n Preferencias 32 63230 319 216B2 11 2011 Esta opci n permite personalizar individualmente cada EGX En el men Configuraci n haga clic en Abre la p gina Preferencias Preferencias Introduzca el nombre del equipo la p gina Establece las preferencias de inicio predeterminada la velocidad de muestreo en tiempo real y de velocidad de comprobaci n de las comunicaciones 3 Haga clic en Aplicar Actualiza la configuraci n de Preferencias de la EGX Figura 26 Pagina Preferencias Preferencias Nombre del equipo Pagina de inicio predeterminada Inicio NA Velocidad de muestreo en tiempo real 5 x Segundos Velocidad de comprobaci n de las comunicaciones Desactivado v Minutos Tabla 13 Valores de las preferencias open ME NN war Nombre del equipo Le permite introducir un nombre Predeterminado personalizado para la EGX y para el equipo Powerlogic EGX300 asociado Este nombre se utilizar en el encabezado de la interfaz web P gina de inicio Le permit
150. X Benutzerkonto haben Siehe Benutzerkonten auf Seite 28 Das EGX kann andere EGX300 Ger te und andere Schneider Electric Ger te die am Netzwerk angeschlossen sind erkennen und entsprechende Links zur Verf gung stellen Damit wird ein Zugangspunkt f r ein System vernetzter Schneider Electric Ger te bereitgestellt Die Seite Systemzugangspunkt listet jedes erkannte Schneider Electric Ger t in Form eines Hyperlinks auf Wenn Sie mit dem Mauszeiger ber ein Ger t in der Liste gehen werden links neben der Liste zus tzliche Details zum Ger t angezeigt Klicken Sie auf ein Ger t um die Anmeldeseite f r dieses Ger t aufzurufen Abbildung 44 Seite Systemzugangspunkt mit Detailanzeige Systemzugangspunkt Plattform Firmwareversion Seriennummer MAC Adresse 00 30 67 80 5B 63 EGx300 Geratename IP Adresse 4000 EE EGX300 169 254 0 20 23395 Powerl ic EGX300 169 254 0 30 12 Aktualisieren L schen 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 UNTERLAGEN STEUERUNG 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Unterlagen ber die Unterlagen Seite k nnen Sie auf Informationen zugreifen die in Form von Dateien und URL Links im EGX gespeichert sind Informationen ber das Laden von Unterlagenlinks finden Sie unter Unterlagenlinks auf Seite 26 Um
151. X para originar la transacci n Cliente FTP Envio correcto Contador que aumenta despu s de cada transferencia con xito a un servidor FTP Error de conexi n Contador que aumenta cada vez que la EGX no puede conectarse al servidor FTP Error de autenticaci n Contador que aumenta cada vez que al servidor FTP no puede autenticar las credenciales del usuario o contrase a Error de directorio Contador que aumenta cada vez que el servidor FTP no puede localizar el directorio solicitado Error de envio Contador que aumenta cada vez que no se puede transferir un archivo al servidor FTP Error general Contador que aumenta cada vez que no se puede transferir un archivo debido a la incapacidad de la EGX para originar la transacci n Cliente SMTP Envio correcto Contador que aumenta cada vez que se envia un correo electr nico con xito al servidor SMTP Error de conexi n Contador que aumenta cada vez que la EGX no puede conectarse al servidor SMTP Error de autenticaci n Contador que aumenta cada vez que el servidor SMTP no puede autenticar las credenciales del usuario o contrase a Error de envio Contador que aumenta cada vez que no se puede enviar un correo electr nico al servidor SMTP Error general Contador que aumenta cada vez que no se puede enviar un correo electr nico debido a la incapacidad de la EGX para crear el correo electr nico Sistema de archivos Espacio total La cantidad total de espacio de disco de la E
152. X300 63230 319 216B2 Index 11 2011 64 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Manuel d utilisation Schneider Electric 295 Tech Park Drive Suite 100 La Vergne TN 37086 USA Support technique Global PMC Tech support schneider electric com 00 1 250 544 3010 Contactez le repr sentant commercial local de Schneider Electric Electric pour obtenir de l aide ou rendez vous sur www schneider electric com PowerLogic est une marque commerciale de Schneider Electric Les autres marques de commerce sont la propri t de leurs d tenteurs respectifs Seul un personnel qualifi doit effectuer l installation l utilisation l entretien et la maintenance du mat riel lectrique Schneider Electric n assume aucune responsabilit des cons quences ventuelles d coulant de l utilisation de cette documentation 63230 319 216B2 11 2011 remplace 63230 319 216B1 08 2011 2011 Schneider Electric Tous droits r serv s PowerLogic Ethernet Gateway EGX300 Benutzerhandbuch 63230 319 216B2 11 2011 Schneider WARNHINWEISE UND SYMBOLE BITTE BEACHTEN FCC ERKL RUNG KLASSE A Lesen Sie die Anweisungen sorgf ltig durch und sehen Sie sich die Ausr stung genau an um sich mit dem Ger t vor der Installation dem Betrieb oder der Wartung vertraut zu machen In dieser Publikation oder auf dem Ger t k nnen sich folgende Hinweise befinden
153. X300 deberian ser retenidos por los destinatarios antes de considerar que esta no est disponible De 2 a 65535 segundos Predeterminado 600 segundos 7 Per odo de vida de multidifusi n Es posible controlar la amplitud del rea de lared para detectar otros dispositivos Se controla mediante el n mero de veces que se permite el reenvio de la multidifusi n a otros El intervalo de saltos de router permitidos es de 1 a 255 Predeterminado 1 8 Comunidad Las EGX300 de un grupo pueden dividirse en comunidades Aquellas pasarelas que tengan la misma direcci n IP del grupo y el mismo n mero de comunidad podr n detectarse entre si Si se configura el n mero de comunidad como 0 ello permitir que una EGX300 detecte todas las EGX300 con la misma direcci n IP de grupo independientemente del valor del par metro de comunidad Predeterminado 0 9 Predeterminados Aplicar Haga clic en Aplicar para guardar las entradas haga clic en Predeterminados para volver a los valores predeterminados que se enumeran Figura 29 Pagina de configuraci n Punto de acceso del sistema Punto de acceso del sistema Activado M Puerto UDP 159 1 65535 Direcci n IP del grupo 224 0 1 2 Tmpo entre mnsj bieny 300 1 65535 Segundos Tiempo de espera 600 2 65535 Segundos Per odo de vida de multidifusi n 1 1 255 Saltos Comunidad o 0 65535 36 O 2011 Schneider Electric Reservados
154. a canadiense ICES 003 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 indice Indice INdiee ea en tds i INTrod CCi N E E E T diia eu daues dati dau dant dec casa de 1 Otros T CUPSOS ZE ses rastas careto nee 1 Acceso a la EGX a trav s de una red Inicio de Sesion en la EGX a anne Descripci n general de la interfaz de usuario de la EGX 3 Configuraci n ss ssnssissennnnnnnnnnnnennnennnennnennnnes Configuraci n de Ethernet y TCP IP Configuraci n avanzada de Ethernet Detecci n de direcciones IP duplicadas 244400n nen 8 Puerto Serl intense e iaa 8 Configuraci n avanzada del puerto serie 9 Conexiones con dispositivos remotos uneesnnnnnnnnnennnnnnen nennen nennen nennen 10 Lista de dispositivos de la EGX Conexi n de dispositivos a una EGX uuernneeesnnnnnnennersnnnn nennen nenne Configuraci n de la lista de dispositivos Detecci n de dispositivos Registro de dispositivos Registro de datos de intervalo Configurar registro por intervalos uuuernnnneennnnnnnnennnnnnnnn nennen Temas que registrar z uu24224440annnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnn nn Exportaci n del registro de dispositivos Exportaci n por correo electr nico Exportaci n por FTP Exportaci n pOr HTTP ee e ER
155. a p gina V nculos de documentaci n V nculos de documentaci n 2 Para acceso a archivo Marque la casilla Define qu archivos y URL aparecen en la de verificaci n Activado correspondiente p gina Documentaci n a los v nculos de Nombre de archivo que desee habilitar Para acceso URL Marque la casilla de verificaci n Activado correspondiente a los v nculos de URL que desee habilitar 3 Marque Ventana nueva si desea que los Define qu archivos y URL se abrir n en una archivos y URL seleccionados se abran en ventana nueva cuando se haga clic en ellos una ventana nueva al hacer clic en ellos 4 Asigne un nombre al t tulo del v nculo de Establece el t tulo del v nculo de documentaci n en la casilla de verificaci n documentaci n que aparecer en la p gina Texto del v nculo Documentaci n 5 Haga clic en Aplicar Actualiza los valores de los v nculos de documentaci n de la EGX O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuracion Figura 22 Pagina Vinculos de documentaci n Vinculos de documentaci n Activado Ventana nueva Nombre de archivo Texto del vinculo El directorio de documentaci n est vac o Activado Ventana nueva URL Texto del v nculo E http E http www PowerLogic com PowerLogic com a a http www Schneider Electric com Schneider Electric com Aplicar NOTA P
156. a seleccionar todos los temas haga clic en deberan registrarse seleccionar todo Para cancelar la selecci n de todos los temas haga clic en borrar Para seleccionar los temas predeterminados haga clic en Predeterminados Guarda la selecci n de temas que se registraran Haga clic en Aplicar 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Exportaci n del registro de dispositivos Exportaci n por correo electr nico Figura 14 Pasarela Ethernet EGX300 de PowerLogic P gina de selecci n de temas Nombre del dispositivo Tipo de dispositivo Building North Panel PM800 do borrar Nombre tema Y Energ a aparente kVAh 7 Energ a activa kWh Y Energ a react KVARh Potencia aparente total kVA Potencia activa total kW Potencia reactiva total KVAR Demanda potencia activa KW Demanda potencia reactiva KVAR Demanda de intensidad 1 Demanda de intensidad 2 Demanda de intensidad 3 Demanda de intensidad 1 ltimo Demanda de intensidad 2 ltimo Demanda de intensidad 3 ltimo Intensidad 1 Intensidad 2 Intensidad 3 Media de intensidad Tensi n 1 2 Tensi n 2 3 Tensi n 3 1 Tensi n media LL Tensi n 1 N Tensi n 2 N Tensi n 3 N Tensi n media L N Predeterminados
157. ables por el usuario correspondientes a los dispositivos seleccionados P ginas de resumen de dispositivos proporciona registros de tendencias en forma de gr ficos de varios dispositivos acerca de un tema espec fico O 2011 Schneider Electric Reservados todos los derechos 3 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Descripcion general de la interfaz de usuario de la EGX 11 2011 Tabla 1 Paginas de la EGX 46 Panel de instrumentos Los paneles de instrumentos proporcionan representaciones en forma de gr ficos y tablas de la informaci n de consumo de energia recopilada a lo largo del tiempo correspondiente a todos los dispositivos a los que se ha habilitado para el registro de datos Punto de acceso del La p gina Punto de acceso del sistema muestra 48 sistema las EGX300 y otros dispositivos en red del sistema que son accesibles desde esta EGX300 Cada linea es un hipervinculo a la p gina de inicio de sesi n de 5 la EGX300 Documentaci n Documentaci n Accede a la documentaci n pertinente de la EGX y 49 a vinculos de documentaci n que podr configurar el usuario Restablecimientos Proporciona lo necesario para la ejecuci n de los 49 restablecimientos definidos para el dispositivo y muestra la fecha y la hora a las que se realiz cada funci n de restablecimiento Los restablecimientos de fecha y hora se muestran solo cuandb el dispositivo los admite Diagn sticos Estadisticas Muestra datos
158. aci n para lectura o Completo que tiene cada grupo de ver una explicaci n de los niveles de usuarios para las p ginas web acceso correspondientes a cada grupo 3 Para permitir el acceso de invitados a la p gina Permite que el grupo Guest web seleccione S lo lectura en la columna predeterminado acceda a la p gina web Guest NOTA Si el grupo Guest es de s lo lectura otros grupos se pueden configurar como S lo lectura o Completo 4 Repita los pasos 2 y 3 para las opciones de cada Selecciona el nivel de acceso para cada secci n p gina web 5 Haga clic en Aplicar Guarda los valores de las contrase as Tabla 12 Acceso de grupo NOTA Para garantizar la seguridad del sistema le recomendamos que cambie la contrase a predeterminada del administrador la primera vez que se conecte al sistema Tres grupos Al elegir entre las siguientes opciones el administrador asigna el acceso a las definidos por p ginas web para cada grupo Los niveles de acceso son los siguientes el usuario Ninguna el grupo no tiene acceso a la p gina web seleccionada S lo lectura la contrase a le concede al grupo acceso de s lo lectura a la p gina web seleccionada Completo el grupo tiene el mismo acceso que el grupo de administradores a la p gina web seleccionada Figura 24 P gina Acceso a p gina Web Acceso a p gina Web Datos en tiempo real S lo lectura S lo lectura S lo lectura x Ninguna v
159. activa kWh Ultimo dia completo Fr MM Building North Panel B Building East Panel 13 2010 02 16 06 00 00 2010 02 16 12 00 00 2010 02 16 18 00 00 2010 02 17 00 00 00 2010 02 17 06 00 00 Seleccione un rea para verla aumentada Pulse Z o haga doble clic para deshacer la visi n aumentada Panel de instrumentos La EGX admite cuatro categor as de paneles de instrumentos que muestran la informaci n de consumo de energ a recopilada a lo largo del tiempo La Tabla 17 enumera los paneles de instrumentos y sus subconjuntos Tabla 17 Tipos de paneles de instrumentos Panel de instrumentos Subconjunto Por horas D a anterior por horas D a actual por horas D a actual con d a anterior por horas Semana anterior por d as Semana actual por d as Semana actual con semana anterior por d as Mes anterior por d as Mes actual por d as Mes actual con mes anterior por d as Por semanas Trimestre anterior por semanas Trimestre actual por semanas Trimestre actual con trimestre anterior por semanas 13 semanas anteriores por semanas Por meses A o anterior por meses A o actual por meses A o actual con a o anterior por meses NOTA Requiere que el archivo de datos de cada dispositivo pueda almacenar dos a os de datos hist ricos Consulte Registro de datos de intervalo en la p gina 17 para obtener m s informaci n 12 meses anteriores por m
160. ada vez que se recibe un mensaje que contiene una CRC que no coincide con la calculada Suele ser el resultado de problemas de cableado Errores de protocolo ador que aumenta cada vez que se recibe un saje mal formado Tiempos de espera Contador que aumenta cada vez que se env a un mensaje de solicitud sin recibir el mensaje de respuesta correspondiente durante el tiempo permitido Los tiempos de espera de respuesta suelen ser el resultado de errores de configuraci n o un dispositivo que no responde Recibidas excepciones Contador que aumenta cada vez que se recibe una excepci n Mensajes salientes de lectura Contador que aumenta cada vez que se env a un mensaje de solicitud de lectura Mensajes salientes de escritura Contador que aumenta cada vez que se env a un mensaje de solicitud de escritura Mensajes entrantes de lectura Contador que aumenta cada vez que se recibe un mensaje de solicitud de lectura Mensajes entrantes de escritura Contador que aumenta cada vez que se recibe un mensaje de solicitud de escritura Detalles Tabla detallada que proporcionar estad sticas remotas y serie por dispositivo Servidor HTTP Tramas enviadas Contador que aumenta cada vez que se env a una trama Tramas recibidas Contador que aumenta cada vez que se recibe una trama Conexiones activas Valor de estado que representa el n mero de conexiones activas en el momento de actualizaci n de la p gina de diagn sticos Se adm
161. al NTP con la que se pone en contacto la EGX para obtener la hora correcta La direcci n IP del servidor secundario NTP con la que se pone en contacto la EGX para obtener la hora correcta UTC 12 00 a UTC 13 00 Predeterminado UTC GMT Primer a Quinto o ltimo Domingo a S bado Enero a Diciembre 0 00 a 23 00 Predeterminado Inicio del horario de verano Segundo Domingo de Marzo a las 2 00 Finalizaci n del horario de verano Segundo Domingo de Noviembre a las 2 00 De 1 hora a 1 semana Predeterminado 1 semana 0 0 0 0 a 255 255 255 255 Predeterminado 0 0 0 0 0 0 0 0 a 255 255 255 255 Predeterminado 0 0 0 0 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Par metros del SNMP Filtrado de Modbus TCP IP Pasarela Ethernet EGX300 de PowerLogic Configuraci n La EGX es compatible con el SNMP lo cual permite que un administrador de red acceda de manera remota a una EGX mediante un gestor de SNMP y visualice el estado de la conexi n y los diagn sticos de la EGX en formato MIB II 1 En el men Configuraci n haga clic en Abre la p gina Par metros del SNMP Par metros del SNMP 2 Marque la casilla de verificaci n Activar SNMP Activa el SNMP para habilitar el protocolo simple de administraci n de redes 3 Introduzca el contacto del sistema el nombre Introduce la informaci n del del sistema su ubicaci n el nombre de la sistema SNMP y los nombres
162. al de donn es Format des journaux 42 63230 319 216B2 11 2011 Vous pouvez r cup rer un journal de donn es d intervalle l aide des m thodes indiqu es dans le Tableau 15 Tableau 15 M thodes de r cup ration des journaux de donn es par intervalle Formats des fichiers Methode de r cup ration Format du fichier r cup r FTP CSV valeurs s par es par des virgules Bouton Acc s aux donn es HTML Requ te Web Microsoft HTML Courrier lectronique CSV HTTP CSV Pour afficher la liste des journaux disponibles effectuez la proc dure d crite aux tapes 2 a 4 de la section Obtention d un journal de donn es d intervalle via FTP page 43 Les fichiers seront d nomm s ainsi Nom d appareil_Identification locale csv o Nom d appareil correspond au nom donn l appareil esclave et Identification locale l identification num rique locale qui lui est attribu e Par exemple un appareil appel Arriv e services B timent et dot de l identification locale 3 donnera le fichier Arriv e services B timent_3 csv En cas d exportation des journaux de donn es la date et l heure sont ajout es au nom du fichier sous la forme _AAAAMMJJHHMMSS Par exemple Arriv e services B timent 1_3_20100218115216 csv Ce nom indique que le fichier a t export le 18 f vrier 2010 11 52 16 Les donn es sont enregistr es au format suivant voir Figur
163. ance de l nergie de nombreux appareils ne peuvent pas conserver les donn es dans une m moire non volatile La passerelle EGX300 peut enregistrer des donn es des intervalles pr d finis en provenance de 64 appareils connect s en s rie et distance La passerelle EGX enregistre les donn es dans des fichiers FIFO premier entr premier sorti non volatiles La capacit de chaque fichier journal varie selon l intervalle d enregistrement s lectionn Pour calculer la capacit d enregistrement d un fichier journal il faut diviser le nombre maximum possible d intervalles enregistr s que peut contenir le fichier 171 072 par le produit du nombre de grandeurs enregistr es et des intervalles enregistr s en un jour Capacit du journal intervalles max grandeurs par intervalle intervalles enregistr s en un jour Par exemple la capacit d enregistrement d un fichier qui enregistre trois grandeurs toutes les 10 minutes serait calcul e comme suit Intervalles enregistr s par jour minutes par jour intervalle d enregistrement en minutes 1440 10 144 intervalles Capacit du journal maximum intervalles possibles grandeurs par intervalle intervalles enregistr s en un jour 171072 3 144 396 jours La capacit d enregistrement est calcul e de fa on dynamique et affich e dans la page S lection de grandeur voir les exemples du Tableau 9 Tableau 9 Exemples d intervalles d enregistremen
164. ant d une s lection d appareils sous forme de tableaux Les Pages r capitulatives appareils affichent le r capitulatif d un ou de plusieurs appareils s lectionn s sous forme de tableaux La page Calcul de tendance offre une vue en temps r el de grandeurs communes pour plusieurs appareils sous forme de graphiques ou de tableaux Journaux d appareil Les Pages d appareil unique fournissent des tendances sous forme de graphiques et de tableaux des valeurs s lectionn es par l utilisateur pour les appareils choisis Les Pages r capitulatives appareils fournissent des tendances pour plusieurs appareils et une grandeur commune sous forme de graphiques Tableaux de bord Les tableaux de bord offrent des repr sentations graphiques et tabulaires des donn es de consommation d nergie agr g es sur la p riode consid r e et pour tous les appareils o l enregistrement des donn es est active gt do gt gt o o N Point d acc s systeme La page Point d acc s syst me affiche les EGX300 et autres appareils syst mes en r seau accessibles depuis cette EGX300 Chaque ligne comporte un hyperlien vers la page de connexion EGX300 2011 Schneider Electric Tous droits r serv s 3 Passerelle Ethernet PowerLogic EGX300 Presentation de l interface utilisateur EGX 63230 319 216B2 11 2011 Tableau 1 Pages EGX Documentation Documentation Permet d acc der la documentation EGX pertinente et 49 au
165. ara borrar registros de datos marque Purgar datos en Selecciona los registros de datos aquellos que desee borrar que se tienen que purgar 1 Para seleccionar todos los dispositivos haga clic en NOTA Para purgar un registro seleccionar todo y a continuaci n en Aplicar de datos el dispositivo no debe 2 Para cancelar la selecci n de todos los dispositivos haga tener habilitada la casilla de clic en borrar y a continuaci n haga clic en Aplicar verificaci n Registro Para deshabilitar el registro seleccione el intervalo de Deshabilita la funci n de registro registro cero aseg rese de que no haya ninguna selecci n de Registro marcada y a continuaci n haga clic en Aplicar Figura 13 P gina Registro de dispositivos Registro de dispositivos Intervalo de registro 15 B Minutos Registro Purgar datos Nombre del dispositivo Tipo de dispositivo seleccionar todo seleccionar todo Personalizar Building Main CM4000 Y temas Building West Panel CM2000 M temas Building East Panel CM3000 temas Building North Panel PM800 temas Es posible seleccionar individualmente los temas que se registraran por cada dispositivo lo cin Resultado En la p gina Registro de dispositivos haga clic en el vinculo Abre la p gina de selecci n temas del dispositivo deseado de temas Consulte la Figura 14 y marque los temas que desee registrar Selecciona los temas que Par
166. ara obtener informacion sobre la manera de acceder a la documentaci n cargada consulte Documentaci n en la p gina 49 O 2011 Schneider Electric Reservados todos los derechos 27 Pasarela Ethernet EGX300 de PowerLogic Configuraci n Cuentas de usuario 28 63230 319 216B2 11 2011 A los usuarios de la EGX se les asignan nombres de usuario y contrase as Cada usuario pertenece a un grupo cuyos derechos de acceso a las p ginas web de la EGX los asigna el administrador de la EGX NOTA Existen dos cuentas de usuario predeterminadas Administrator cuya contrase a predeterminada es Gateway y Guest cuya contrase a predeterminada es Guest 1 Enel men Configuraci n haga clic Abre la p gina Cuentas de usuario en Cuentas de usuario 2 Si desea cambiar el nombre de un Introduce un nuevo nombre de grupo grupo escriba el nuevo nombre en uno de los cuadros de texto Grupos no se puede cambiar el nombre del grupo Administradores 3 En la secci n Usuarios introduzca un Introduce el nombre y la contrase a de un usuario nombre 1 a 24 caracteres y contrase a 0 a 12 caracteres para el La EGX300 comprueba el grado de la seguridad de nuevo usuario la contrase a mostrando una indicaci n crom tica y textual de su solidez Rojo Contrase a en blanco contrase a no segura Contrase a de seguridad media Contrase a segura Contrase a muy segura 4 Seleccione un grupo y el idioma Selecciona e
167. as enviadas 0 Colisiones 0 Tramas recibidas 0 Colisiones excesivas 0 Errores de protocolo 0 Tramas recibidas satisfactoriamente 93220 Ci Il ivas 0 Errores de CRC de tramas 0 Conexiones acumuladas 1 Errores de alineaci n 0 M ximo de conexiones 1 Tramas demasiado largas 0 Mensajes entrantes de lectura 0 Tramas demasiado cortas 0 Mensajes entrantes de escritura 0 Mensajes salientes de respuesta 0 A J a J Tramas enviadas 1950 Lie ee i Tramas recibidas 1950 de CRC de tramas 0 Exxon CE moc s Errores de protocolo 0 Delia m g Tiempos de espera de conexi n 0 Tiempos de espera 0 Recbid E 0 Recibidas excepciones 0 DE EXE CONES Mensajes salientes de lectura 1950 Mensajes salientes de lectura 0 n linens na de Sachin o Mensajes salientes de escritura 0 u Mensajes entrantes de respuesta 1950 Mensajes entrantes de lectura 0 4 4 Detalles Mensajes entrantes de escritura 0 Detalles Tramas enviadas 970 x Tramas recibidas 898 Versi n del firmware 3 740 ere gt Conexiones activas Tiempo de inactividad del sistema 96 a Sn Direcci n MAC 00 80 67 80 5B 61 fi s M ximo de conexiones 6 Numero de serie 0 Numero de modelo EGX300 Versi n del hardware Cente TTR Fecha de fabricaci n 2006 01 01 Envio correcto 0 Error de conexi n 0 A E o P Error de URL 0 Envio correcto 0 en Error de envio 0 Error de conexi n 0 BE E 0 Error de autenticaci n 0 genera Error de directorio 0 Error de
168. atenprotokoll Assembly Pnl PM8 PM800 Letzte vollst ndige Woche E Zeilen g Datenpunkte EE Scheinenergie kVAh 2011 09 20 00 00 00 2011 00 00 2011 09 24 00 00 00 2011 09 2 Wahlen Sie den Bereich der eingezoomt werden soll Bet tigen Sie die Z Taste oder f hren Sie einen Doppelklick aus um das Zoomen r ckg ngig zu machen Abbildung 37 Datenpunkttabelle des Intervalldatenprotokolls Gelieferte Bezogene Gel Energie Bez Energie paier Zeitstempel Energie kWh Energie KWh KV AR RVARh 0 2009 01 08 19 05 00 348 0 150 0 D 2009 01 08 18 40 00 348 0 150 0 O 2009 01 08 18 45 00 348 0 150 0 O 2009 01 08 18 50 00 348 0 150 0 O 2009 01 08 18 55 00 348 0 150 0 D 2009 01 08 19 00 00 348 0 150 0 O 2009 01 08 19 05 00 348 0 150 0 O 2009 01 08 19 10 00 348 0 150 0 O 2009 01 08 19 15 00 348 0 150 0 0 2009 01 08 19 20 00 348 0 150 D O 2009 01 08 19 25 00 348 0 150 D 41 PowerLogic Ethernet Gateway EGX300 berwachung Abrufen eines Datenprotokolls Protokollformat 42 63230 319 216B2 11 2011 Intervalldatenprotokolle k nnen mit den Methoden in Tabelle 15 abgerufen werden Tabelle 15 Methoden zum Abrufen von Intervalldatenprotokollen und Dateiformate Abrufmethode Abgerufenes Dateiformat FTP CSV Format Variablen durch Komma getrennt Schaltfl che Datenpunkte HTML Um eine Liste aller vorhandenen Protokolldateien anzuzeigen f hren Sie die Schritte 2 bis 4 im Absc
169. bar FTP se aplican los Acciones valores del FTP para exportaci n de registros y se transfiere un archivo de prueba y al hacer clic en Aplicar s lo se aplican los valores Figura 16 P gina Exportaci n de registro de dispositivos FTP Exportaci n del registro de dispositivos Transporte O Desactivado O Correo electr nico FTP O HTTP Incremental Planificar O Intervalo de registro Cada hora Diariamente Semanalmente Mensualmente Hora del dia 00 00 D a de la semana D a del mes Par metros del FTP Direcci n IP del servidor 0 0 0 0 Puerto TCP del servidor 21 Directorio Nombre de usuario user Contrase a Pasivo Probar FTP NOTA Si el transporte se programa como Cada hora o como Intervalo de registro la casilla de verificaci n Incremental se seleccionar autom ticamente O 2011 Schneider Electric Reservados todos los derechos 21 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Configuracion 11 2011 Exportaci n por HTTP 1 En la p gina Configuraci n haga clic en Abre la p gina Exportaci n del registro de Exportaci n del registro de dispositivos dispositivos 2 Seleccione HTTP como modo de Abre las opciones de exportaci n de registro transporte de dispositivos por HTTP 3 Habilite la casilla de verificaci n Selecciona para su env o s lo los nuevos Incremental dato
170. bernehmen und oder bernehmen der FTP HINWEIS Durch das Anklicken von FTP pr fen Finstellungen werden die FTP Einstellungen f r den Export des Protokolls bernommen und eine Testdatei bertragen Wird bernehmen angeklickt werden nur die Einstellungen bernommen Abbildung 16 Seite Gerateprotokollexport FTP Gerateprotokollexport Ubertragung Deaktiviert O E Mail FTP O HTTP Inkrementell Zeitplan Aufzeichnungsintervall St ndlich T glich W chentlich Monatlich Tageszeit 00 00 3 Tag der Woche Tag des Monats 1 E FTP Parameter Server IP Adresse 0 0 0 0 Server TCP Port 21 Verzeichnis Benutzername user Kennwort eeecsceeee Passiv Manueller Export FTP pr fen bernehmen HINWEIS Wenn die bertragung St ndlich oder zum Aufzeichnungsintervall geplant ist wird das Kontrollk stchen Inkrementell automatisch aktiviert 2011 Schneider Electric Alle Rechte vorbehalten 21 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 HTTP Export 1 Klicken Sie auf der Setup Seite auf Einblendung der Seite f r den Ger teprotokollexport Ger teprotokollexport 2 W hlen Sie HTTP als bertragungsart Einblendung der Optionen f r den Export des Ger teprotokolls ber HTTP 3 Aktivieren Sie das Kontrollk stchen Hiermit werden nur neue seit dem letzten Inkremente
171. bidas Contador que aumenta cada vez que se recibe una trama Errores de protocolo Contador que aumenta cada vez que se recibe un mensaje mal formado THaga clic en el v nculo para obtener informaci n adicional en detalle O 2011 Schneider Electric Reservados todos los derechos 51 Pasarela Ethernet EGX300 de PowerLogic M Diagn sticos 52 63230 319 216B2 11 2011 Tiempos de espera Contador que aumenta cada vez que se env a un mensaje de solicitud sin recibir el mensaje de respuesta correspondiente durante el tiempo permitido Los tiempos de espera de respuesta suelen ser el resultado de errores de configuraci n o un dispositivo que no responde Tiempos de espera de conexi n Contador que aumenta cada vez que se pierde la conexi n Recibidas excepciones Contador que aumenta cada vez que se recibe una excepci n Mensajes salientes de lectura Contador que aumenta cada vez que se env a un mensaje de solicitud de lectura Mensajes salientes de escritura Contador que aumenta cada vez que se env a un mensaje de solicitud de escritura Mensajes entrantes de respuesta Contador que aumenta cada vez que se recibe un mensaje de respuesta Detalles Tabla detallada que proporcionar estad sticas remotas y serie por dispositivo Puerto serie Tramas enviadas ador que aumenta cada vez que se env a una a Tramas recibidas ador que aumenta cada vez que se recibe una a Errores de CRC de tramas Contador que aumenta c
172. bseiten hinzufuegen entfernen PowerLogic Ethernet Gateway EGX300 Setup Benutzerdefinierte Webseiten hinzuf gen entfernen Hinzuf gen von Webseiten mit FTP L schen von Webseiten mit FTP 30 63230 319 216B2 11 2011 Benutzerdefinierte Webseiten und andere Dateien k nnen von Ihrem Computer ber FTP auf das EGX bertragen werden ber FTP in die Verzeichnisse www monitoring berwachung www maintenance Wartung oder www control Steuerung bertragene Dateien mit den Erweiterungen htm html oder shtml werden automatisch gesichert F r jeden Ordner ist auf der Men leiste der Webschnittstelle ein entsprechender Link vorhanden Wenn in der Men leiste der Link angeklickt wird erscheinen die von Ihnen hinzugef gten Webseiten auf der linken Seite des Browserfensters unter Benutzerdefinierte Seiten HINWEIS In den Ordnern berwachung Steuerung oder Wartung k nnen keine neuen Ordner erstellt werden Nach der bertragung von benutzerdefinierten Webseiten oder anderen Dateien ber FTP in das EGX k nnen die Webseiten und Dateien mithilfe der Seite Webseiten hinzuf gen entfernen zur Webschnittstelle hinzugef gt werden bzw von der Webschnittstelle entfernt werden ohne sie im EGX zu l schen Diese Seite wird von der Seite Webseitenzugriff aus ge ffnet Starten Sie Windows Explorer geben Sie ffp und die Einblendung des Dialogfelds IP Adresse des EGX zum Beispiel ftp 169 2
173. bus TCP IP definidos por el usuario Podr introducirlas manualmente o seleccionarlas a partir de una tabla que recoge las conexiones detectadas por la funci n Punto de acceso del sistema consulte la Figura 7 Estas conexiones se ponen a disposici n de la configuraci n de la lista de dispositivos para la configuraci n de dispositivos remotos Acci n Resultado 1 Enel men Configuraci n haga clic en Abre la p gina Conexiones con dispositivos Conexiones con dispositivos remotos remotos Para agregar una conexi n manualmente Introduce las direcciones IP de los dispositivos introduzca la direcci n IP de los remotos dispositivos remotos a los que desee conectarse Para agregar una conexi n detectada Introduce la direcci n IP correspondiente a la gracias a la funci n Punto de acceso del conexi n detectada por la funci n Punto de sistema haga clic en A adir a la derecha acceso del sistema que haya seleccionado de la conexi n que desee en la tabla de conexiones detectadas 4 Haga clic en Aplicar Actualiza la configuraci n de las conexiones con dispositivos remotos de la EGX O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuraci n Figura 7 Conexiones con dispositivos remotos Conexiones con dispositivos remotos A
174. cada Syslog Direcci n IP del servidor A medida que se generen los mensajes estos se reenviar n al servidor que indique Puerto UDP del servidor Los mensajes de Syslog se protocolo de datagramas enviar n desde este puerto UDP de usuario del servidor Introduzca la direcci n IP del servidor remoto al que quiere reenviar los mensajes Introduzca el n mero de puerto UDP correspondiente a esta direcci n IP Predeterminado 514 Informe Cuatro tipos de informes cuyos Marque los tipos de informes mensajes se pueden reenviar cuyos mensajes desee reenviar Lista desplegable Instalaci n Proporciona una idea aproximada de la ubicaci n del sistema donde se gener el mensaje Aparece en Syslog Lista desplegable Gravedad relativa del mensaje Debe determinar para su instalaci n la importancia de cada tipo Elija la categor a adecuada Le indica al usuario la importancia Elija la categor a adecuada Correo electr nico Desde direcci n Cuando se generan mensajes la direcci n de correo electr nico del emisor aparece en el campo del remitente El cuerpo del correo electr nico incluir la direcci n IP de la EGX el nombre del grupo de informes el nombre de usuario la direcci n IP del usuario y el mensaje del grupo de informes A direcciones Cuando se generan los mensajes se env an a las direcciones de correo electr nico de los destinatarios Direcci n IP del servidor Esta es
175. cal ID E Remote ID You must define the Remote ID E 14 O 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Device Discovery 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup The Device Discovery option enables the EGX to discover Modbus devices residing on the serial port that are not in the Device List Devices that have been previously entered into the Device List are validated regardless of the discovery range set Discovery When you begin Device Discovery the EGX queries the local serial port using a user defined address range see Figure 12 on page 16 Modbus ASCII or RTU protocol is used for discovery on the serial connection depending on the current serial port configuration If the device replies to the query the Local ID is set to the current discovery address and the device is given a default device name The EGX then tries to identify the device type If the EGX recognizes the device type of the discovered device the EGX enters the recognized device type name in the Device Type field If the EGX does not recognize the device type the Device Type field is set to the default Modbus A status field displays the discovery status Validation All previously defined Device List entries for all connections serial and remote in and out of the discovery start and end address range are validated during the discovery process The validation p
176. cciones ARP para ver si alg n dispositivo de la red utiliza la misma direcci n IP En la Tabla 4 a continuaci n se explica c mo trata la EGX las direcciones duplicadas al detectarlas Tabla 4 Situaciones de detecci n de IP duplicadas F LED de Situaci n lercupligeda detectads alimentaci n estado Proceso de inicio resta Vuelve a la direcci n IP la m scara de Patr n de 4 parpadeos y blecimiento de alimenta subred y la direcci n de la pasarela ci n predeterminadas de la EGX Las solicitudes ARP se env an cada 15 segundos hasta que la direcci n IP queda disponible Cuando la direcci n IP quede disponible la EGX la utilizar Enlace de Ethernet detectado Cambio manual de la La EGX mantiene su direcci n IP direcci n anterior y muestra un mensaje que indica que otro dispositivo ya la est empleando Recibe una solicitud ARP Vuelve a la direcci n IP la mascara de Patr n de 4 parpadeos y subred y la direcci n de la pasarela predeterminadas de la EGX si un dispositivo conectado env a cuatro solicitudes ARP de la direcci n IP de la EGX La EGX enviar solicitudes ARP cada 15 segundos hasta que la direcci n IP vuelva a quedar disponible Cuando la direcci n IP quede disponible la EGX la utilizar 1 Enel men Configuraci n haga clic en Abre la p gina Puerto serie Puerto serie 2 Seleccione la interfaz f sica el modo de Selecciona las opciones del puerto serie transmisi n la
177. chnell wie m glich vorgenommen k nnen aber je nach Kommunikationslast im seriellen Subnetz und oder auf den entfernten Ger ten l nger dauern W hlen Sie Abtastung starten aus um die Start der Trendverfolgung Trendverfolgung der ausgew hlten Ger tegr en zu starten HINWEIS Die Trendverfolgung kann vor dem Ablauf der Trendzeit durch Klicken auf Abtastung anhalten angehalten werden Wenn nach dem Anhalten der Abtastung Abtastung starten angeklickt wird wird eine neue Trendkurve gestartet Klicken Sie auf Datenpunkte um ein Protokoll aller Anzeige eines Protokolls aller abgetasteten Gr en anzuzeigen die w hrend der Gr enwerte die w hrend der Trendzeit aufgezeichnet wurden Trendverfolgung abgetastet HINWEIS Nach jedem Intervall werden die Angaben wurden Aktueller Wert f r alle Gr en sowie die berechneten Werte Min Max und Mittelwert in die Tabelle unter dem Diagramm eingetragen Klicken Sie auf Neue Gr e n um Ger te und Gr en Navigation zur ck zur Setup f r die Trendverfolgung neu auszuw hlen Seite Echtzeit Trendverfolgung Abbildung 35 Echtzeit Trendverfolgung Echtzeit Trendverfolgung 2010 02 16 06 03 09 O Absolutwert Relativwert 1 E Minuten _ Datenpunite _ Neue Themen _ __Abtastung starten 140 123 105 88 70 06 02 06 268 06 02 18 268 06 02 30 268 06 02 42 268 06 02 54 268 06 03 06 268 Min Aktueller W
178. copia en el portapapeles Inicie Excel y luego pulse CTRL V Pega los datos en una hoja de c lculo de Excel Para evitar tener que hacer selecciones desde el men principal cada vez que se accede a un panel de instrumentos utilice uno de los m todos indicados en la Tabla 18 para guardar un panel de instrumentos Tabla 18 Guardar un panel de instrumentos Opcion Descripcion Marcador del explorador Permite a los usuarios acceder al Siga las instrucciones para web panel de instrumentos guardado configurar un marcador en el desde el equipo donde se cre el explorador web que utilice marcador Vinculo de Permite a los usuarios de la EGX Para configurar el acceso URL documentaci n acceder a un panel de instrumentos consulte Vinculos de guardado desde la p gina documentaci n en la Documentaci n p gina 26 Correo electr nico Permite a los usuarios enviar Para que el destinatario del la URL de un panel de instrumentos mensaje pueda ver un panel de en el cuerpo de un mensaje de instrumentos debe tener una correo electr nico cuenta de usuario de la EGX Consulte Cuentas de usuario en la p gina 28 La EGX es capaz de detectar pasarelas EGX300 y otros dispositivos Schneider Electric que esten conectados a la red asi como de proporcionar enlaces a estos Se obtiene asi un punto de acceso a un sistema de dispositivos Schneider Electric en red La p gina Punto de acceso del sistema enumera e
179. criture Messages de r ponse en partance Compteur qui augmente d une unit chaque envoi d un message de r ponse Trames envoy es Compteur qui augmente d une unit chaque envoi d une trame Trames recues Compteur qui augmente d une unit chaque r ception d une trame Erreurs de protocole Compteur qui augmente d une unit chaque r ception d un message de format incorrect Cliquez sur le lien pour plus d informations 51 Passerelle Ethernet PowerLogic EGX300 Diagnostics 52 63230 319 216B2 11 2011 Delais d attente Compteur qui augmente d une unit chaque fois qu un message ne re oit aucune r ponse dans le temps imparti Il s agit en g n ral de la cons quence d erreurs de configuration ou d un appareil d faillant D lai d attente connexion Compteur qui augmente d une unit chaque fois que la connexion a t perdue Exceptions re ues Compteur qui augmente d une unit chaque r ception d une exception Messages de lecture en partance Compteur qui augmente d une unit chaque envoi d un message de demande de lecture Messages d criture en partance Compteur qui augmente d une unit chaque envoi d un message de demande d criture Messages de r ponse en arriv e Compteur qui augmente d une unit chaque r ception d un message de r ponse D tails Tableau d taill pr sentant des statistiques s rie et distantes par appareil Trames envoy es Compteu
180. d sactivations de fonctions Vous n avez pas besoin d ajouter des entr es pour ces l ments Enfin le journal liste aussi les activit s sp cifi es pour le Journal de maintenance dans la page de configuration Piste d audit voir Piste d audit page 33 1 Dans le menu Maintenance cliquez sur Ouvre la page Journal de maintenance Journal de maintenance 2 S lectionnez la case cocher Supprimer Supprime l entr e s lectionn e en regard de l entr e supprimer puis cliquez sur Supprimer des entr es 3 Cliquez sur Effacer le journal pour Efface le journal de maintenance supprimer toutes les entr amp es contenues dans le journal de maintenance 4 Pour ajouter une nouvelle entr amp e au Ouvre la page Ajouter une entr e de journal et journal cliquez sur Ajouter une entr e de permet l utilisateur de saisir les d tails de la journal puis saisissez le texte de maintenance maintenance dans la zone de texte Detail entree voir Figure 51 ci dessous Figure 50 Journal de maintenance Journal de maintenance Supprimer des entr es _ Effacer ie journal _ Ajouter une entr e de journal Supprimer Date et heure Utilisateur D tail entr e 2010 05 10 14 09 Administrator F Test Figure 51 Ajouter une entr e de journal Journal de maintenance Date etheure Utilisateur D Ctail entr Oe 2009 01 12 15 32 Administrator Vous pouv
181. d grants a group read only access to the selected web page Full a group has the same access as the Administrator group to the selected web page Figure 24 Web Page Access Page Web Page Access Real Time Data Read only Read only Read only None Device Log Data Read only Read only Read only None Resets Read only Read only Read only None Statistics Reac only Read only Read only None Read Device Registers Read only Read only Read only None Communications Check Read only Read only Read only None Maintenance Log Read only Read only Read only None Ethernet amp TCP IP Read only Read only Read only None y Serial Port Fe Reac ony Reac ony E None W Remote Device Connections Read only y Read only y Read only y None y Device List Read oniy Y Read ony E Reac ony Il None E Device Logging Read only y Read only Read only Read only y Viewable Device Types Read only y Read only y Read only y None y Device Log Export Read only y Read only y Read only gt None gt Documentation Links Read only y Read only y Read only y Read only gt Preferences Read only y Read only y Read only y None gt Audit Trail Rezo il Eco Reac ony I None I Apply 29 PowerLogic Ethernet Gateway EGX300 Setup Add Remove Custom Web Pages Adding Web Pages Usin
182. dation des appareils distants La passerelle EGX affiche l identification locale le nom d appareil et le type d appareil m moris s partir de la liste des appareils puis elle interroge l appareil Elle affiche alors le type d appareil identifi par cette requ te puis le compare au type d fini pr c demment L tat indique alors s il existe une diff rence ou si la configuration d finie pr c demment est valide REMARQUE Vous pouvez modifier le nom et le type de l appareil et s lectionner individuellement les appareils stocker dans la liste des appareils N anmoins si l enregistrement de journaux est activ pour un appareil vous ne pouvez modifier que son nom 1 Dans le menu Configuration cliquez sur Ouvre la page Liste des appareils Liste des appareils 2 Pour d tecter les appareils connect s Ouvre la page D tection des appareils localement cliquez sur D tection 3 Saisissez l adresse de d but et l adresse D finit la plage d adresses de d tection REMARQUE Les appareils saisis pr c demment dans la liste des appareils et dont les adresses identifications locales se trouvent en dehors de la plage de d tection seront valid s 4 Cliquez sur Lancer la d tection Cliquez D bute la d tection de tous les appareils sur Arr ter la d tection pour arr ter le connect s et d finis processus REMARQUE La d tection ne d tecte que les appareils Modbus s rie connect s localement la pa
183. dbus TCP IP iniciada por la EGX Cantidad de tiempo que la EGX esperar a que un dispositivo remoto Modbus TCP IP responda a una solicitud de conexi n Modbus TCP IP iniciada por la EGX Un temporizador que cierra la conexi n Modbus TCP IP despu s de una cantidad especificada de tiempo de inactividad El valor de 0 deshabilita esta opci n 1 a 255 saltos Predeterminado 60 saltos 0 a 65 000 segundos Predeterminado 30 segundos 0 a 60 segundos Predeterminado 15 segundos 0 a 65 000 minutos Predeterminado 15 minutos Desactivado o Activado Predeterminado Activado 30 a 900 segundos Predeterminado 120 segundos 0 a 65 000 segundos Predeterminado 4 segundos 0 a 65 000 Predeterminado 80 0 Desactiva el puerto HTTP De 1 a 65 000 Predeterminado 443 0 Desactiva el puerto HTTPS 0 a 65 000 Predeterminado 100 16 a 64 Predeterminado 32 Desactivado Activado o Activado con respuesta Predeterminado Desactivado Desactivado o Activado Predeterminado Activado 0 1 a 10 Predeterminado 5 segundos De 1 a 10 Predeterminado 2 segundos 0 a 32 767 segundos Predeterminado 0 Pasarela Ethernet EGX300 de PowerLogic Configuraci n Detecci n de direcciones IP duplicadas Puerto serie 63230 319 216B2 11 2011 Mientras esta conectada a la red la EGX publica su direcci n IP Para evitar conflictos de direcciones IP duplicadas la EGX utiliza el protocolo de resoluci n de dire
184. dbus connect s au port s rie qui ne sont pas dans la liste des appareils Les appareils saisis pr c demment dans la liste sont valid s quelle que soit la plage de d tection configur e D tection Lorsque vous lancez la d tection des appareils la passerelle EGX interroge le port s rie local sur une plage d adresses d finie par l utilisateur voir la Figure 12 page 16 La d tection sur la connexion s rie utilise le protocole Modbus ASCII ou RTU selon la configuration active du port s rie Si l appareil r pond la requ te l identification locale prend l adresse d tect e et l appareil re oit un nom par d faut La passerelle EGX essaie alors d identifier le type d appareil Si la passerelle EGX reconna t le type de l appareil d tect elle indique le nom correspondant dans la zone Type d appareil Si la passerelle EGX ne reconna t pas le type d appareil la zone Type d appareil prend la valeur par d faut Modbus Une zone d tat affiche l tat de la d tection Validation Toutes les entr es d finies pr c demment dans la liste des appareils pour l ensemble des connexions s rie et distantes qu elles soient ou non comprises dans la plage d adresses de la d tection sont valid es pendant le processus de d tection Sur la connexion s rie le protocole de validation est d termin par la configuration actuelle de l appareil dans la liste des appareils Le protocole Modbus TCP IP est utilis pour la vali
185. de cada intervalo se a aden a la tabla tendencia que aparece bajo el gr fico el valor Actual de todos los temas as como los valores Min M x y Media calculados Pulse Tema s nuevo s para volver a seleccionar los Le lleva de nuevo a la p gina dispositivos y los temas cuyas tendencias se deben de configuraci n Tendencias generar en tiempo real Figura 35 Tendencias en tiempo real Tendencias en tiempo real 2010 02 16 05 58 03 O Absoluto Relativo 1 E Minutos __ Puntos de datos Tema s nuevo s Iniciar muestreo 140 123 De A ae oe 105 SS SS _ 88 70 05 57 00 037 05 57 12 037 05 57 24 037 05 57 36 037 05 57 48 037 05 58 00 037 Min Actual Max Media Building East Panel Potencia activa total kW 110 110 112 110 3 Building East Panel Potencia aparente total kVA 112 113 114 113 2 Building North Panel Potencia activa total KW 102 105 106 1041 Building North Panel Potencia aparente total kVA 115 117 119 116 6 Registro de dispositivos Las p ginas de Registro de dispositivos proporcionan representaciones en forma de gr ficos y tablas de los datos de registro de los dispositivos seleccionados Para obtener m s detalles acerca de la configuraci n del registro de dispositivos consulte Registro de dispositivos en la p gina 17 40 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Superv
186. de dispositivos Predeterminado Activado Conexi n Muestra la conexi n en la que se ha Puerto serie o direcci n IP detectado o validado el dispositivo para validaci n de dispositivos remotos Definido Muestra el tipo de dispositivo definido para este dispositivo Asignado Le permite asignar el tipo de dispositivo de la lista desplegable Nombre Le permite introducir un nombre personalizado para el dispositivo ID local Muestra el ID local del dispositivo Estado Muestra el estado de detecci n o V lido Desconocido Error validaci n Encontrado Detectando o Intentando 16 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuraci n Registro de dispositivos El registro de datos est disponible para todos los tipos de dispositivos admitidos por la EGX La EGX es capaz de registrar a intervalos predefinidos 5 10 15 20 30 y 60 minutos datos procedentes de dispositivos conectados tanto local como remotamente A continuaci n se ofrece una explicaci n de c mo registra datos la EGX y c mo se configura el registro para un dispositivo Registro de datos de intervalo Muchos de los dispositivos de un sistema de supervisi n de potencia no poseen la capacidad para registrar datos en una memoria no volatil La EGX300 proporciona este tipo de registro de datos a intervalos predefinidos para un m ximo de 64 dispositivos conectados en serie y rem
187. de menus Figure 2 Page d accueil EGX PowerLogic EGX300 Schneider Dosen Sureitance O O Maintenance U Confieuration P Electric Barre de menus Version de logiciel embarqu 3 800 Copyright 2005 2010 Schneider Electric Tous droits r serv s Utlisateur 1 Nous vous recommandons de vous d connecter d s que vous n avez plus besoin d acceder la passerelle EGX Pour fermer la session EGX cliquez sur D connexion ou fermez le navigateur 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Pr sentation de l interface utilisateur EGX PRESENTATION DE L interface utilisateur EGX comporte plusieurs pages Web destin es la L INTERFACE UTILISATEUR EGX surveillance et la commande d appareils ainsi qu la configuration et au diagnostic de la passerelle EGX Voir le Tableau 1 pour la description de chaque page Tableau 1 Pages EGX Configuration Ethernet et TCP IP Configure les param tres des communications Ethernet 5 et TCP IP Port s rie Configure les param tres de communication s rie Connexions d appareils Configure les connexions d appareils Modbus TCP IP distants distants Liste des appareils EGX Configure identifie ou v rifie les appareils s rie locaux 1 raccord s la guirlande Les appareils distants peuvent uniquement tre configur s et v rifi s Journaux d appareil Conf
188. del SNTP intervalo de adquisici n y las direcciones IP de los servidores principal y secundario NTP consulte la Tabla 10 3 Haga clic en Aplicar Guarda la configuraci n del SNTP Figura 19 Activar la sincronizaci n horaria de red Fecha y hora Activar sincronizaci n horaria de red M Fecha Hora Par metros de zona horaria Desviaci n de zona horaria UTC 06 00 x Habilitar ajuste autom tico del horario de verano Inicio del horario de verano de a la s Finalizaci n del horario de verano de a la s Par metros del SNTP Intervalo de adquisici n 1 hora y Direcci n IP del servidor principal NTP 0 D D D Direcci n IP del servidor secundario NTP 0 D D D ltima sincronizaci n horaria satisfactoria Fecha y hora Direcci n IP del servidor Tabla 10 Configuraci n de los parametros del SNTP Desviaci n de zona La hora se establece sobre la base del horaria Habilitar ajuste autom tico del valor seleccionado de la hora universal coordinada UTC Permite definir cu ndo comienza y termina el horario de verano horario de verano Intervalo de adquisici n Direcci n IP del servidor principal NTP Direcci n IP del servidor secundario NTP Controla la frecuencia con la que la EGX se pone en contacto con el NTP para obtener la hora correcta La direcci n IP del servidor princip
189. der Electric All Rights Reserved 63230 319 216B2 11 2011 Device Logging Interval Data Logging Set Up Interval Logging 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup Logging is available for every device type supported by the EGX The EGX can log data received from both local and remotely connected devices at predefined intervals 5 10 15 20 30 and 60 minutes Below is an explanation of how the EGX logs data and how to set up logging for a device Many devices in a power monitoring system do not have the ability to record data in non volatile memory The EGX300 provides this data logging at predefined intervals for up to 64 serially and remotely connected devices The EGX stores the recorded data in non volatile FIFO First In First Out files The logging capacity for each data log file is variable and dependent on the selected logging interval Logging capacity of each data log file can be calculated by dividing the maximum possible number of recorded intervals a data log file can contain 171 072 by the product of the number of topics logged and the intervals recorded per day Log File Capacity Intervals max topics per interval intervals recorded per day For example the logging capacity for a device data log recording three topics every 10 minutes would be determined as follows Intervals Recorded Per Day Minutes per day Logging Interval in minutes 1440 1
190. des appareils EGX Connexion d appareils une passerelle EGX ue mn nennen 12 Configuration de la liste des appareils 13 D tection des appareils Journaux d appareil 4444400nn nn nnennnennnnnnenn Enregistrement des donn es par intervalle Configuration de l intervalle d enregistrement TENA Exporter le journal de l appareil Exportation par courrier lectronique Exportation par FTP Exportation par HI IP ns Date et he re it he menant tue Synchronisation de l heure r seau Param tres SNMP iio ini ane Mina Filtrage Modbus TCP IP ee Liens vers la documentation nenn nnnenenennn nenne ernennen nn Gomptes tilisateur 2 2 222 ar odie ines Acc s aux pages Web Ajout Suppression de pages Web personnalis es 30 Ajout de pages Web personnalis es par FTP 30 Suppression de pages Web personnalis es par FTP 30 Ajout Suppression de pages Web personnalis es l aide de l interface Web Nuits reine naines 31 Pr f rences viii aii a a iara dde init 32 Types d appareil affichables rennen nennen nnnennnnnnn nennen nn 33 Piste audit economicas Point d acc s syst me Surveillance ss ii ii Donn es en temps r el Pages d appareil unique ooooooconocccccnccoococccnconanancnnncnonnncnnnnnnn nn nn nnnnnnnns Param tres des mesures de base Plage des cadrans analogiques Pages r capit
191. des messages vous le souhaitez Valeurs par d faut Cliquez sur Appliquer pour Cliquez sur Appliquer ou Appliquer enregistrer vos s lections Cliquez Valeurs par d faut sur Valeurs par d faut pour r tablir la valeur initiale d un champ Figure 28 Configuration de la piste d audit Piste d audit Journal de maintenance Rapport Erreur syst me Erreur de s curit Configuration Information Syslog Adresse IP du serveur 0 D o D Port UDP du serveur 514 1 65535 Installation Gravit Rapport Erreur syst me LocalO 16 Erreurs 3 M O Erreur de s curit Auth 4 Avertissements 4 A Configuration Localo 16 BA Notifications 5 E O Information Local0 16 Ez Information 6 Courrier lectronique De l adresse Aux adresses Adresse IP du serveur 0 o 0 Port TCP du serveur 25 1 65535 Connexion au serveur SMTP via authentification Nom d utilisateur Mot de passe Rapport Erreur systeme Erreur de s curit Configuration Information Valeurs par d faut Appliquer Le Point d acc s syst me sert d tecter et relier la passerelle les autres appareils Schneider Electric connect s au r seau Cette fonction est activ e par d faut et ne n cessite pas d autre configuration Utilisez cet cran de configurati
192. dispositivos se validan independientemente del intervalo de detecci n establecido Detecci n Cuando inicia una detecci n de dispositivos la EGX consulta el puerto serie local utilizando un intervalo de direcciones definido por el usuario consulte la Figura 12 de la p gina 16 Para la detecci n en la conexi n en serie se utiliza el protocolo Modbus ASCII o RTU dependiendo de la configuraci n del puerto serie actual Si el dispositivo contesta a la consulta el ID local se establece en la direcci n de detecci n actual y se proporciona al dispositivo un nombre de dispositivo predeterminado La EGX intenta entonces identificar el tipo de dispositivo Si la EGX reconoce el tipo de dispositivo del dispositivo detectado la EGX introduce el tipo de dispositivo reconocido en el campo Tipo de dispositivo Si la EGX no reconoce el tipo de dispositivo el campo Tipo de dispositivo se establece al valor predeterminado Modbus Un campo de estado muestra el estado de detecci n Validaci n Todas las entradas de Lista de dispositivos previamente definidas para todas las conexiones serie y remotas ya est n aquellas dentro o fuera del intervalo de direcciones de comienzo y fin de detecci n se validan durante el proceso de detecci n El protocolo de validaci n en la conexi n serie se determina en funci n de la configuraci n actual del dispositivo en la lista de dispositivos El protocolo TCP IP se utiliza para la validaci n de disposit
193. dresses l expediteur des courriers destinataires sp cifi es lectroniques dans le champ pr vu cet effet Maximum 49 caract res par adresse Adresse IP du serveur Adresse IP du serveur o les Si vous ne sp cifiez pas courriers lectroniques seront Padresse IP du serveur aucun envoy s courrier lectronique ne sera envoy Port TCP du serveur Numero de port TCP pour l adresse Saisissez le num ro de port IP du serveur TCP La valeur par d faut est 25 Connexion au serveur Cochez cette case pour activer la Cochez cette option pour SMTP via connexion pour la r ception des entrer les informations de authentification courriers lectroniques La connexion connexion au serveur SMTP exige une authentification Nom d utilisateur Nom d utilisateur que l EGX utilisera Tapez le nom d utilisateur pour acc der au serveur SMTP exig par le serveur SMTP maximum 31 caract res Mot de passe Mot de passe que l EGX utilisera Tapez le mot de passe exig pour acc der au serveur SMTP par le serveur SMTP maximum 31 caract res 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Point d acc s syst me 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Configuration Types de rapport pour lesquels des Cochez les types de rapport messages peuvent tre r exp di s pour lesquels vous souhaitez Vous pouvez en cocher autant que envoyer
194. e barres Lorsque vous survolez l une des barres du graphique avec la souris la valeur du point de donn es s affiche pour l intervalle s lectionn Figure 42 Figure 42 Graphique de tableau de bord PM5350 ID32 Energie active kWh Jour en cours sur jour pr c dent par heure a Jour en cours Figure 43 Tableau de tableau de bord PM5350 ID32 Energie active kWh Jour en cours sur jour pr c dent par heure 2011 Schneider Electric Tous droits r serv s Sun Nov 27 00 00 00 CST 2011 Sun Nov 27 01 00 00 CST 2011 Sun Nov 27 02 00 00 CST 2011 Sun Nov 27 03 00 00 CST 2011 Sun Nov 27 04 00 00 CST 2011 Sun Nov 27 05 00 00 CST 2011 Sun Nov 27 06 00 00 CST 2011 Sun Nov 27 07 00 00 CST 2011 Sun Nov 27 01 00 00 CST 2011 Sun Nov 27 02 00 00 CST 2011 Sun Nov 27 03 00 00 CST 2011 Sun Nov 27 04 00 00 CST 2011 Sun Nov 27 05 00 00 CST 2011 Sun Nov 27 06 00 00 CST 2011 Sun Nov 27 07 00 00 CST 2011 Sun Nov 27 08 00 00 CST 2011 Passerelle Ethernet PowerLogic EGX300 Surveillance 63230 319 216B2 11 2011 Acc s aux donn es de tableau de bord par le biais du bouton Acc s aux donn es Proc dez comme suit pour exporter les donn es d un tableau de bord sous la forme d une feuille de calcul Action R sultat Depuis le tableau de bord contenant les Affiche les points de donn es pour le tableau donn es cliquez sur Acc s aux donn es de bord s lectionn Figure 43
195. e mails Maximum 49 characters per address Server IP Address This is the IP address for the server where the e mails will be sent If you do not enter a server IP address no e mails will be sent Server TCP Port MTP server requires login Username This is the TCP port number for the server IP address Use this check box to enable login for receiving e mails The SMTP server requires login Is Is the user name the X will use to log on to the SMTP server Enter the TCP port number The default is 25 eck the box to begin adding login information ype the username required by the SMTP server max 31 characters ype the password required se to log on to the SMTP server by the SMTP server max Password is Is the password the X wi u ese are the report types for which messages can be forwarded You can check as many as you want 31 characters e report types for which you want messages Defaults Apply Click Apply to save the entries you have made Click Defaults to return each field to its default state Click Apply or Defaults 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 System Access Point 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup Figure 28 Audit Trail Setup Audit Trail Maintenance Report M System Error M Security Error M Configuration Informational Server IP Address
196. e Device Log Export must be configured for FTP see FTP Export on page 21 1 Create a folder on your computer such as Creates a folder to store the EGX data log c egx_logs 2 Launch Windows Explorer type fto and Opens the Log On As dialog box the IP address of the EGX in the Address text box for example ftp 169 254 0 10 then press Enter 3 Type the user name Administrator and the Opens an FTP session with the EGX and administrator password in the text boxes displays the files stored in the EGX then click Log On 4 Navigate to the directory logging data on Opens the data logging directory on the EGX the EGX 5 Copy the log file then paste it into the Copies the data log to your folder folder you created in step 1 O 2011 Schneider Electric All Rights Reserved 43 PowerLogic Ethernet Gateway EGX300 Monitoring Getting an Interval Data Log Using the Data Points Button Getting an Interval Data Log Using the Microsoft Web Query Feature Getting an Interval Data Log Using E mail Getting an Interval Data Log Using HTTP 44 63230 319 216B2 11 2011 1 From the Device Logging web page see Opens a new window displaying the logged Figure 36 click Data Points data 2 Press CTRL A then press CTRL C Selects all of the data then copies the data to the clipboard 3 Open Excel then press CTRL V Pastes the data into an Excel spreadsheet 1 Launch your web browser Opens the w
197. e EGX HINWEIS Wenn Sie die Firmware k rzlich aktualisiert haben dr cken Sie F5 um die Webseite und die angezeigte Firmwarenummer zu aktualisieren 3 Alternativ k nnen Sie auf Diagnose gt Alternative Feststellung der Statistik klicken um die Firmwareversion im Firmwareversion des EGX Abschnitt Gateway Informationen zu finden Firmwareversion der Datei Image Starten Sie Windows Explorer geben Sie ftp Einblendung des Dialogfelds Anmelden und die IP Adresse des EGX in das Adressentextfeld ein z B ftp 169 254 0 10 und dr cken Sie die Eingabetaste Geben Sie in die Textfelder den Er ffnung einer FTP Sitzung mit dem EGX Benutzernamen Administrator und das Administratorkennwort ein und klicken Sie auf Anmelden Suchen Sie die Datei version txt und Anzeige der Firmwareversion der Datei doppelklicken Sie dann auf die Datei um sie Image Komponente zu ffnen Neue Firmware herunterladen ee 1 Starten Sie den Webbrowser geben Sie Einblendung der PowerLogic Website www powerlogic com in das Adressentextfeld ein und dr cken Sie die Eingabetaste 2 W hlen Sie Ihr Land aus und klicken Sie auf Einblendung der PowerLogic Website f r Ihr Go Start Land HINWEIS Wenn Sie United States ausgew hlt haben fahren Sie mit Schritt 3 fort Anderenfalls folgen Sie der l nderspezifischen Navigation um die EGX Firmware zu erhalten 3 Klicken Sie auf Support gt Downloads Einblendung
198. e Si se corta la alimentaci n el ctrica durante el proceso de programaci n la EGX dejar de funcionar Estando en curso la programaci n el indicador LED de estado parpadear r pidamente Cuando cesa el parpadeo la programaci n est terminada 1 Inicie el Explorador de Windows escriba ftp y la direcci n IP de la EGX en el cuadro Direcci n por ejemplo ftp 169 254 0 10 y luego pulse Intro Escriba el nombre de usuario Administrator y la contrase a de administrador en los cuadros de texto y luego haga clic en Iniciar sesi n Localice el directorio o la carpeta del equipo donde se ha guardado el archivo de firmware egxxxxx bin haga clic con el bot n derecho en el archivo y a continuaci n haga clic en Copiar Haga clic con el bot n derecho en la ventana del Explorador de Windows y luego haga clic en Pegar NOTA En vez de copiar y pegar el archivo del firmware puede arrastrarlo y soltarlo en el Explorador de Windows Localice el archivo de actualizaci n del disco guardado en su equipo egxxxxx upd haga clic con el bot n derecho en el nombre del archivo y a continuaci n haga clic en Copiar Haga clic con el bot n derecho en la ventana del Explorador de Windows y luego haga clic en Pegar NOTA En vez de copiar y pegar el archivo del firmware puede arrastrarlo y soltarlo en el Explorador de Windows Para verificar que se ha actualizado correctamente la versi n del firmware siga lo
199. e 38 page 43 Tableau 16 Format des journaux de donn es d intervalle BOM Nom passerelle N s rie Cette ligne contient les en t tes de colonne passerelle Adresse passerelle Nom des informations affich es la ligne 2 appareil ID appareil local Nom type appareil intervalle enregistrement REMARQUE BOM Les trois premiers octets du fichier forment une marque d ordre des octets Byte Order Mark d notant le format UTF 8 EGX300SD 23227 157 198 184 116 Cette ligne contient les informations relatives Arriv e services B timent 1 3 la passerelle EGX et l appareil CM4000 15 enregistr Identification grandeur 1 ldentification Cette ligne contient les en t tes de colonne grandeur 2 ldentification grandeur 3 des identifications de grandeurs affich es la ligne 5 L identification d une grandeur est une r f rence num rique la grandeur sur laquelle porte l enregistrement Le nom attribu a une grandeur peut diff rer selon les appareils et la langue Les identifications de grandeurs permettent d identifier les grandeurs ind pendamment de l appareil ou de la langue Les trois premi res virgules servent la mise en page dans un tableur 1617 1621 1625 Cette ligne contient les identifications de grandeurs des valeurs consign es Erreur D calage par rapport a temps Cette ligne contient les en t tes de colonne universel UTC minutes Horodatage des donn es enregistr es pr sent es ligne 8 loca
200. e Data gt Trending 1 From the Monitoring menu select Real Time Data Expands the data tree for real time data option selection 2 Select Trending Expands the data tree for time trending option selection 3 Select Real Time Trending Opens the Real Time Trending setup page 4 Select up to four device from the Available Devices list Selects devices for trending 5 Select a topic s from the Available Topics list Selects topics for trending NOTE Only topics common to all selected devices are available for trending The maximum number of topics to trend is dependent on the number of devices selected The product of the selected devices and topics must be 8 or less 6 Click Next to open the Real Time Trending display page Real Time Trending display page opens 7 To set the trending parameters continue to the Allows trending parameters to procedure in the next table and refer to Figure 35 be set Figure 34 Select Devices and Topics Select Devices and Topics Available Devices Available Topics Building Main Current A Building West Panel Current B Building East Panel Current C Building North Panel Current Avg Voltage A B Voltage B C Voltage C A Voltage L L Avg Voltage A N Voltage B N Voltage C N Voltage L N Avg Next Real Power Total kW Reactive Power Total kVAR Apparent Power Total kVA Demand Current A Demand Current B Demand Current C Frequency Hz 1 Select Absolute o
201. e Devices 12 2011 Schneider Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Setup Device List Setup From the Setup menu click Device List Opens the Device List page See Figure 10 for local only connections or see Figure 11 if remote connections are available 2 You can use Discover to find locally Opens the Device Discovery page to discover connected devices see Device all locally connected devices Discovery on page 15 If remote device configuration is required proceed to step 3 3 Refer to Figure 11 on page 14 and select Selects the number of viewable locations that the number of viewable devices 1 to 64 can be used to define devices connected to the ECK 4 Select the Connection from the Selects the connection drop down list 5 Select the Device Type from the Selects the device type drop down list In the Device Name text box type the Enters the device name device name In the Local ID text box type the address Enters the local address of the device of the serial slave device ifit is on the serial port or type the address you want to use to access a remote device 8 In the Remote ID text box type the Enters the address of the remote device address of the remote device 9 Repeat steps 4 through 8 until all of the Enters all of the connected devices devices are entered 10 Click Apply Updates the Device List settin
202. e EGX Reportez vous la documentation de l appareil connect pour plus d informations sur les valeurs stock es dans un registre Type de donn es Permet de s lectionner les registres de maintien les Registres de registres d entr e les bobines de sortie les bobines maintien d entr e ou l identification d appareil Options D cimal S lection d une option pour sp cifier l affichage des D cimal Hexad cimal Binaire donn es de la colonne Valeur ou ASCII 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Verification des communications Verification automatique des communications V rification manuelle des communications 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Diagnostics Lorsque vous parcourez les affichages de donn es en temps r el la passerelle EGX effectue une v rification automatique des communications toutes les 15 minutes par d faut Pour changer la fr quence voir Pr f rences page 32 Cette op ration v rifie l tat des communications de tous les appareils configur s sur la passerelle EGX et essaie de r tablir la communication avec tous les appareils marqu s hors service dans la session de navigation actuelle Dans certains cas il peut s av rer pr f rable de ne pas attendre l intervalle de v rification automatique des communications et d ex cuter la v rification manuellement Dans le menu
203. e auf bernehmen Aktualisierung der Einstellungen f r die serielle EGX Schnittstelle Abbildung 5 Seite Serielle Schnittstelle Serielle Schnittstelle Physikalische Schnittstelle RS485 2 Leiter y Ubertragungsmodus Automatisch Baudrate 19200 j E Parit t Gerade y Antwort Zeit berschreitung 3 p Sekunden Erveitert bernehmen 8 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Erweiterte Einstellungen der seriellen Schnittstelle 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Setup Tabelle 5 Einstellungen der seriellen Schnittstelle Physische Auswahl der physischen Verdrahtung der RS485 4 Leiter RS485 Schnittstelle seriellen EGX Schnittstelle 2 Leiter oder RS232 Werkeinstellung RS485 2 Leiter bertragungs Hier wird festgelegt wie Daten ber die Automatisch modus serielle Verbindung bertragen werden Modbus ASCII HINWEIS Im Automatikmodus kann das Ger t mit Modbus RTU Jbus und PowerLogic SY MAX Slave Ger ten in der gleichen Ger tekette kommunizieren 2400 4800 9600 19200 38400 56000 oder 57600 Baudrate Hier wird die Geschwindigkeit der Daten bertragung ber die serielle Verbindung festgelegt Werkeinstellung 19200 Parit t Hier wird die Art der Parit t festgelegt die Gerade Ungerade oder Keine f r die berpr fung der Richtig
204. e configuraci n de la lista de dispositivos IN A EE 1 En el men Configuraci n haga clic en Tipos de dispositivos Abre la p gina Tipos de visualizables dispositivos visualizables 2 Seleccione los tipos de dispositivos que estar n disponibles Selecciona los tipos de para la configuraci n de la lista de dispositivos dispositivos que estar n disponibles para configurar la lista de dispositivos NOTA Haga clic en seleccionar todo para habilitar todos los dispositivos y en borrar para deshabilitar todos ellos NOTA Es posible que no se pueda cambiar la disponibilidad del tipo de dispositivo de aquellos dispositivos que ya se est n utilizando 3 Haga clic en Aplicar Guarda los valores de Tipos de dispositivos visualizables Figura 27 Pagina Tipos de dispositivos visualizables Tipos de dispositivos visualizables E Yonar todo Dorrar TIPO de dispositivo M ATS48 M ATV61 Y ATV71 M Accusine M BCM Y BCPM Model A M BCPM Model B Y tal C Historial de auditor a El historial de auditor a consiste en una secuencia de registros o mensajes con una marca horaria Graba los eventos de cambio de configuraci n error o fallo de autenticaci n tambi n identifica al usuario que desencaden el evento La p gina Historial de auditor a permite configurar los cuatro grupos de informes y canales de mensajes Por cada canal elija los grupos de informes cuyos mensajes
205. e de la EGX 3 Haga clic en Support gt Downloads Abre la p gina de descargas Asistencia gt Descargas 4 Haga clic en el v nculo EGX300 Firmware Abre la p gina Firmware de la EGX300 Firmware de la EGX300 5 Haga clic en el v nculo del archivo de Abre el cuadro de di logo Descarga de firmware egxxxx bin donde xxxx es el archivos y a continuaci n el cuadro de di logo n mero de la versi n del firmware luego Guardar como haga clic en Guardar 6 En el cuadro de di logo Guardar como Guarda el archivo de firmware en el directorio o seleccione o cree un directorio o carpeta la carpeta indicados local en el que se almacenar el archivo de firmware y haga clic en Guardar 7 Haga clic en el v nculo egxxxx upd donde Abre el cuadro de di logo Descarga de xxx es el n mero del firmware luego archivos y a continuaci n el cuadro de di logo haga clic en Guardar Guardar como 8 En el cuadro de di logo Guardar como Guarda el archivo de firmware con la extensi n seleccione o cree un directorio o carpeta upd en el directorio o la carpeta indicados local en el que se almacenar el archivo de firmware y haga clic en Guardar O 2011 Schneider Electric Reservados todos los derechos 57 Pasarela Ethernet EGX300 de PowerLogic Firmware Actualizaci n del firmware 58 63230 319 216B2 11 2011 No corte la alimentaci n electrica a la EGX mientras se est amp descargando firmwar
206. e el archivo se export el 18 de febrero de 2010 alas 11 52 16 a m Los datos se registran en el siguiente formato consulte la Figura 38 de la p gina 43 Tabla 16 Formato de registro de datos de intervalo BOM Nombre de pasarela N de serie de Esta fila contiene los encabezamientos pasarela Direcci n de pasarela Nombre del de las columnas para la informaci n de la dispositivo ID local de dispositivo Nombre del fila 2 tipo de dispositivo Intervalo de registro NOTA BOM Los tres primeros bytes del archivo constituyen una marca de orden de bytes BOM Byte Order Mark de 3 caracteres lo cual indica UTF 8 2 EGX3008D 23227 157 198 184 116 Entrada Esta fila contiene la informaci n acerca de servicios del edificio 1 3 CM4000 15 de la EGX y el dispositivo registrado D del tema 1 ID del tema 2 ID del tema 3 Esta fila contiene los encabezamientos de las columnas de los ID de los temas de la fila 5 Un ID de tema es una referencia num rica de la cantidad que se est registrando El nombre dado a una cantidad puede diferir ligeramente entre dispositivos e idiomas Los ID de temas se utilizan para identificar la cantidad independientemente del dispositivo y del idioma Las tres primeras comas se utilizan con fines de disposici n en una aplicaci n de hoja de c lculo 5 1 1617 1621 1625 Esta fila contiene los ID de temas de los valores registrados 7 Error Desviaci n de la UTC Minutos Indica Esta fila conti
207. e seleccionar la p gina de inicio Inicio predeterminada predeterminada Resumen de circuito Resumen de intensidad de carga Resumen de la demanda de intensidad Resumen de potencia o Resumen de energ a Predeterminado Inicio Velocidad de muestreo Controla la frecuencia con la que se leen 5 a 60 segundos en tiempo real los datos procedentes de los dispositivos Predeterminado de las vistas est ndar de Tabla de 5 segundos supervisi n Velocidad de Controla la frecuencia con la que se realiza Desactivado 5 a comprobaci n de las la comprobaci n de las comunicaciones 30 minutos comunicaciones mientras el navegador est mostrando Predeterminado lecturas en tiempo real en las vistas 15 minutos est ndar de Tabla de supervisi n Esta funci n intentar poner de nuevo en servicio autom ticamente cualquier dispositivo que se encuentre fuera de servicio O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuracion Tipos de dispositivos visualizables La pagina Tipos de dispositivos visualizables proporciona una manera de gestionar los tipos de dispositivos disponibles para que el usuario pueda seleccionarlos en la pagina web de configuraci n de la lista de dispositivos Dado que la EGX300 admite muchos tipos diferentes de dispositivos retirarlos de la lista de tipos de dispositivos disponibles quizas simplifique el ajuste de la pagina web d
208. e tienen que agregar manualmente Consulte Conexiones con dispositivos remotos en la p gina 10 5 Introduzca un nombre del dispositivo nuevo Cambia el nombre del dispositivo en el cuadro de texto Nombre 6 Marque la casilla de verificaci n Guardar Selecciona una entrada de dispositivo que situada junto al dispositivo que desee guardar se ten a que guardar o suprimir o cancela la en Lista de dispositivos selecci n de esta 7 Haga clic en Aplicar en la p gina Detecci n Guarda en la lista de dispositivos la de dispositivos configuraci n de todos los dispositivos que se han marcado para ser guardados O 2011 Schneider Electric Reservados todos los derechos 15 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Configuraci n 11 2011 Figura 12 Detecci n de dispositivos Detecci n de dispositivos 2011 09 26 16 15 08 PM6 modhus PM6 modhus PM650 1 22 43 CM3000 CM3000 CM3350 44 CM4000 CM4000 CM4250 45 Iniciar detecci n Aplicar Tabla 8 Opciones de detecci n de dispositivos opci n Descripci n Valor Direcci n de Define el intervalo de direcciones Modbus De 1 a 247 comienzo fin que se utilizar para detectar dispositivos Predeterminado conectados al puerto serie de la EGX comienzo 1 fin 10 Guardar Le permite guardar el dispositivo Activado o desactivado seleccionado en Lista
209. e type Unit ID 0 ou Activ avec D sactiv tous les messages sont ignor s Activ r ponse tous les messages sont trait s comme des Par d faut messages a diffusion g n rale en direction des ports D sactiv s rie n appelant pas de r ponse Activ avec r ponse tous les messages sont trait s comme des messages ordinaires en direction des ports s rie avec r ponse attendue Proxy Modbus TCP D termine si les messages Modbus TCP IP D sactiv ou Activ provenant de clients distants seront achemin s aux Par d faut Activ appareils Modbus TCP IP distants d finis dans la passerelle EGX D lai d attente du Temps que doit attendre la passerelle EGX pour 0 1 10 client Modbus qu un appareil Modbus TCP IP distant r ponde une Par d faut TCP IP demande Modbus TCP IP lanc e par la passerelle 5 secondes EGX D lai d attente de la Temps que doit attendre la passerelle EGX pour 1310 connexion client qu un appareil Modbus TCP IP distant r ponde une Par d faut Modbus TCP IP demande de connexion Modbus TCP IP lanc e par 2 secondes la passerelle EGX D lai d inactivit de D compte permettant de fermer une connexion 0 32 767 s la connexion Modbus TCP IP apr s le temps d inactivit d fini Par d faut 0 serveur Modbus Entrez la valeur 0 pour d sactiver cette fonction TCP IP Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Configuration 11 2011 D tection des adre
210. e vos identifiants de connexion au mot de passe dans les zones de texte serveur 12 Si vous souhaitez utiliser une connexion Tous les journaux d appareil export s via HTTP SSL pour l exportation cochez cette seront d sormais export s via SSL HTTPS option 13 Cliquez sur Test HTTP pour effectuer un Envoie un fichier de test au serveur et test des param tres HTTP que vous avez r pertoire HTTP et ou applique les d finis ou cliquez sur Appliquer param tres HTTP REMARQUE Lorsque vous cliquez sur Test HTTP les param tres d exportation du journal par HTTP sont appliqu s et un fichier de test est transf r Lorsque vous cliquez sur Appliquer les param tres sont simplement appliqu s 22 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Date et heure 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Configuration Figure 17 Page Exporter le journal de l appareil par HTTP Exporter le journal de l appareil O D sactiv Caurrier lectronique OFTP HTTP Incr mentale O Intervalle d enregistrement Ohoraire Quotidien O Hebdomadaire Mensuel 00 00 Heure Jour de la semaine C Jour du mois i a Adresse IP du serveur 0 o o o Port TCP du serveur 80 Chemin Nom de champ datafile1 Nom d h te _ nom d h te virtuel facultatif Nom d uti
211. eb browser 2 Verify that the log file is available by typing Opens the data log page the EGX300 IP address followed by stream deviog_data html device x where x is the device local ID 3 Launch Excel then click Data gt Import Opens the Excel New Web Query dialog box External Data gt New Web Query NOTE The path shown is typical for Microsoft Excel 2003 4 In the New Web Query dialog box type Opens the data log file the address of the log you entered in step 2 then click Go 5 Click the outer most arrow to select all of Selects the data then opens the Import Data the data then click Import dialog box 6 Click OK Imports the data NOTE If you want to display the latest data each time you open the spreadsheet click Properties on the Import Data dialog and select Refresh data on file open The EGX must be configured to deliver data logs to an e mail address For more information see E mail Export on page 19 The EGX must be configured to deliver data logs to a web server For more information see HTTP Export on page 22 2011 Schneider Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Monitoring Summary Device Pages The Summary Device views provide summaries of one or more selected devices 1 From the Monitoring menu click Device Expands the tree for device logging choices Logging 2 Under Device Logging click Summary Dev
212. ectr nico Incremental FTP O HTTP Planificar Hora del dia 00 00 3 Dia de la semana Dia del mes 1 ul O Intervalo de registro O Cada hora Diariamente Semanalmente Mensualmente Desde direcci n Par metros del correo electr nico A direcciones Direcci n IP del servidor 0 i 0 10 Puerto TCP del servidor 25 El servidor SMTP requiere iniciar sesi n Nombre de usuario Contrase a Exportaci n manual Correo electr nico de prueba O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuracion Exportacion por FTP 1 En la p gina Configuraci n haga clic en Exportaci n Abre la p gina Exportaci n del del registro de dispositivos registro de dispositivos 2 Seleccione FTP como modo de transporte Abre las opciones de exportaci n de registro de dispositivos por FTP 3 Habilite la casilla de verificaci n Incremental Selecciona para su env o s lo los nuevos datos registrados desde el NOTA Si el transporte se programa como Cada hora ltimo intervalo de env o correcto o como Intervalo de registro la casilla de verificaci n Incremental se seleccionar autom ticamente NOTA Si no se selecciona la casilla de verificaci n Incremental se enviar el archivo de registro completo por FTP en cada intervalo programado
213. ed 63230 319 216B2 11 2011 SETUP Ethernet and TCP IP Settings 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup To access the Setup web page links click Setup on the EGX menu bar 1 From the Setup menu click Ethernet amp Opens the Ethernet amp TCP IP page TCP IP 2 Select your frame format and media type Selects the frame format and media type Contact your network administrator if you do not know 3 Enter your IP address subnet mask and Enters the Ethernet parameters for the EGX default gateway address assigned to your NOTE Ifyou enter an IP address that is used EGX by your network administrator by another device you will be prompted to select a new IP address See Duplicate IP Address Detection on page 8 4 Click Apply Updates the EGX Ethernet and TCP IP settings See Table 2 below for a list of options Figure 3 Ethernet amp TCP IP Page Ethernet amp TCP IP Ethemet MAC Address 00 80 67 80 54 91 1 Frame Format Ethernet Il bd v Media Type 10T 100Tx Auto IP Parameters I Obtain an IP Address Automatically IP Address 169 254 jo 110 Subnet Mask 255 255 255 0 Default Gateway 169 254 0 10 Table 2 EGX Ethernet and TCP IP Settings Frame Format Used to select the format for data sent over Ethernet Il 802 3 SNAP an Ethernet connection Default
214. eeeeeeeeeeseeaeeeeeeeecaeeeeeeseeeeeeeeeee 55 Automated Communications Check 55 Manual Communications Check 55 Maintenance rar arara maraa a aaa aaa raaa raa aea Eaa An ia aAa Aerar Esanen Ears 56 FIFMWAFC EE A T Finding the Firmware Version Executable Binary Component Firmware Version 57 File Image Component Firmware Version 57 Getting New Firmware 2uuusssssnnesnnsnsnnnnnennnnnnnnnanennnnnnnnnannnnnnnnnnnnnnnnnenn 57 Updating the Firmware sis 58 Appendix A Supported Ethernet Protocols ccccncccnccccnnnicccnasonennnnno 59 Hardware rer codes sin eiiiai iaa ediad cestuesesedaeceestgteeddeneesensecies 59 Appendix B Supported Device Types nn 60 ii 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 INTRODUCTION Additional Resources 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Introduction The EGX300 is an Ethernet based device providing a transparent interface between Ethernet based networks and field devices Field devices include meters monitors protective relays PLCs trip units motor controls and other devices that communicate using Modbus Jbus or PowerLogic protocol The EGX300 uses Modbus TCP IP protocol to access field device information across a local area network LAN or a wide area network WAN This capability allows the use of monitoring software to access information from devices for data collection trending ala
215. efault 0 time A setting of 0 disables this setting PowerLogic Ethernet Gateway EGX300 Setup Duplicate IP Address Detection Serial Port 63230 319 216B2 11 2011 While connected to your network the EGX publishes its IP address To avoid any duplicate IP address conflicts the EGX uses the Address Resolution Protocol ARP to see if any other device on your network is using the same IP address Table 4 below explains how the EGX handles a duplicate IP address when it is detected Table 4 Duplicate IP Detection Scenarios Scenario Duplicate IP Detected Power Status LED Boot Process Reverts to the default EGX IP address Four blinks pause pattern Power Restore subnet mask and gateway address A ARP requests are sent every 15 Ethemet Link Detected seconds until the IP address is available When the IP address becomes available the EGX will use it Manual Address Change EGX keeps its previous IP address and displays a message indicating that the IP address is already in use by another device Receives an ARP request Reverts to the default EGX IP address Four blinks pause pattern subnet mask and gateway address ifa connected device sends four ARP requests for the EGX s IP address The EGX will send ARP requests every 15 seconds until the IP address is available again When the IP address becomes available the EGX will use it 1 From the Setup menu click Serial Port Opens the Serial Port
216. eginning of a new request on the serial line Silent Interval Allows the silent interval used to signify the 0 to 15 characters Extension end of a ModbusRTU packet to be Default 6 characters extended beyond the 3 5 characters defined by the standard Modbus TCP IP Indicates the exception response code Ox0A or Ox0B Timeout Exception returned when a serial device connected to Default 0x0B Code the EGX does not respond before the serial port timeout Modbus TCP IP uses Ox0B However in some legacy software suites Ox0A was used Remote Device Connections The EGX can open connections for up to 16 unique user defined remote Modbus TCP IP devices You can enter connections manually or select them from a table of System Access Point discovered connections see Figure 7 These connections are made available to the Device List Setup for remote device configuration 1 From the Setup menu click Remote Opens the Remote Device Connections page Device Connections 2 To manually add a connection enter the IP Enters the IP addresses of the remote devices addresses for the remote devices to which you want to connect 3 Toadd a System Access Point discovered Enters the IP address of the selected System connection click Add to the right of the Access Point discovered connection desired connection in the Discovered Connections table 4 Click Apply Updates the EGX Remote Device Connections settings 10 O 2011 Schneid
217. einen Unterlagenlink zu ffnen klicken Sie auf den Link Unterlagen oben auf der Seite und w hlen Sie danach den gew nschten Link aus Abbildung 45 Unterlagenseite Schneider PowerLogic EGX300 ES Electric Startseite Unterlagen err Steuerung Diagnose wartung setup Unterlagen Schneider Elecir Firmwareversion 3 800 Copyright 2005 2010 Schneider Electric Alle Rechte vorbehalten Benutzer g Das EGX kann manuell eine oder mehrere Gruppen vordefinierter R ckstellbefehle pro Ger tetyp ausf hren 1 Klicken Sie im Men Steuerung auf Einblendung der Seite Resets Resets 2 W hlen Sie in der Liste unter Resets das Auswahl eines Ger ts und Anzeige seiner Ger t aus das Sie betrachten oder R ckstelloptionen sowie des Datums und der zur ckstellen m chten Uhrzeit der letzten R ckstellung 3 W hlen Sie die Ger teparameter aus die Festlegung des am ausgew hlten Ger t Sie zur ckstellen m chten durchzuf hrenden R ckstellvorgangs 4 Klicken Sie auf R cksetzen Senden der R cksetzbefehle f r die geforderten R ckstellvorg nge an das ausgew hlte Ger t und Anzeige des Status Abbildung 46 Resets Resets Building 1 Feeder 1 Sub panel A Parameter Datum Uhrzeit letzter Reset Status Min Max o Spitzenmittelwert o Kumulierte Energie o Css HINWEIS Das Datum und die Uhrzeit die f r den Parameter Datum Uhrzeit
218. eiteinstellungen Einstellung des Beginns und Endes der Abbildung 18 Seite Datum und Uhrzeit Datum und Uhrzeit Netzweerkzeitsynchronisation aktivieren 2008 v sanuar w 26 v 16 53 x 52 y E Zeitzonenausgleich UTC 06 00 lv Automatische Sommerzeiteinstellung aktivieren U Sommerzeit beginnt kunde nntag von M um 02 00 Sommerzeit endet Erste nntag von November um 23 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Netzwerkzeitsynchronisation Mit der Aktivierung der Netzwerkzeitsynchronisation kann die Uhrzeit und das Datum der EGX Systemuhr durch einen NTP Server Network Time Protocol eingestellt werden HINWEIS Wenn sich der NTP Server nicht auf demselben Ethernet Netzsegment wie das EGX befindet achten Sie auf die richtige Konfiguration des EGX Standard Gateway Markieren Sie das Kontrollk stchen Einblendung des SNTP Netzwerkzeitsynchronisation aktivieren auf der Parameterabschnitts und der letzten erfolgreichen Zeitsynchronisation Seite Datum und Uhrzeit 2 Konfigurieren Sie die Zeitzonenabweichung das Einstellung der SNTP Parameter Aufrufintervall und die IP Adresse des prim ren und sekund ren NTP Servers siehe Tabelle 10 3 Klicken Sie auf bernehmen Speicherung der SNTP Einstellungen 24 Abbildung 19 Netzwerkzeitsynchronisation aktivieren Datum und Uhrzeit Netzwerkzei
219. em Verfahren in der nachstehenden Tabelle fort Parameter f r die und beachten Sie dazu Abbildung 35 Trendverfolgung Abbildung 34 Auswahl von Ger ten und Gr en Ger te und Gr en ausw hlen Verf gbare Ger te Verf gbare Themen Building Main Strom L1 Building West Panel Strom L2 Building East Panel Strom L3 Building North Panel Strom Durchschnitt Spannung 1 2 Spannung 2 3 Spannung 3 1 Spannung L L Durchschnitt Spannung 1 N Spannung 2 N Spannung 3 N Spannung L N Durchschnitt Gesamtwirkleistung kW Gesamtblindleistung kVAR Gesamtscheinleistung kVA Strommittelwert L1 Strommittelwert L2 Strommittelwert L3 Frequenz Hz 39 PowerLogic Ethernet Gateway EGX300 berwachung Ger teaufzeichnung 40 63230 319 216B2 11 2011 W hlen Sie die Trendverfolgungsoption Absolutwert oder Auswahl des Diagrammmodus Relativwert aus HINWEIS Mit der Option Absolutwert wird die X Achse des Diagramms nach jeder Abtastung neu gezeichnet und das Diagramm wird mit allen Daten gef llt die seit dem Start der Trendkurve erfasst wurden Mit der Option Relativwert wird das Diagramm nach jeder Abtastung mit den neuesten Daten aktualisiert wobei die X Achse konstant bleibt um die ausgew hlte Gesamttrendzeit anzuzeigen W hlen Sie eine Trendzeit zwischen 1 und 15 Minuten Auswahl der Dauer der aus Das ist die Dauer der Trenddarstellung Trenddarstellung HINWEIS Datenabtastungen werden so s
220. en Klicken Sie unter bersichtsger teseiten Einblendung der Setup Seite f r Mehrere auf Mehrere Ger te Einzelgr e Ger te Einzelgr Re W hlen Sie ein Ger t aus der Liste Auswahl der Ger te f r die bersichtsoptionen Verf gbare Ger te aus HINWEIS Es k nnen maximal vier Ger te ausgew hlt werden W hlen Sie eine Gr e aus der Liste Auswahl der anzuzeigenden Gr e f r jedes Verf gbare Gr en aus ausgew hlte Ger t HINWEIS Es sind nur Gr en verf gbar die alle ausgew hlten Ger te gemeinsam haben 6 Klicken Sie auf Weiter Einblendung der Trendseite Mehrere Ger te Einzelgr e 7 Halten Sie die linke Maustaste gedr ckt Vergr erte Darstellung des ausgew hlten und ziehen Sie einen Auswahlrahmen um Diagrammbereichs den Diagrammbereich der vergr ert dargestellt werden soll 8 Um zur urspr nglichen Vollansicht Die Ansicht wird verkleinert zur ckzukehren geben Sie Z auf Ihrer Tastatur ein oder doppelklicken Sie auf das Diagramm Die von den ausgew hlten Ger ten aufgezeichnete Gr e wird auf einer Webseite in einem Zeitgang Diagrammformat dargestellt Das Zeitgang Diagramm ist f r die Anzeige der Daten vom letzten vollst ndigen Tag von der letzten vollst ndigen Woche vom letzten vollst ndigen Monat oder aller Daten vorkonfiguriert Energieparameter werden als inkrementelle Werte auf der Basis von Intervallen angezeigt Alle anderen Parameter w
221. en Bereich aus der Dropdown Liste Datenbereichs Datenbereich aus 5 Halten Sie die linke Maustaste gedr ckt und Vergr erte Darstellung des ziehen Sie einen Auswahlrahmen um den ausgew hlten Diagrammbereichs Diagrammbereich der vergr ert dargestellt werden soll 6 Um zur urspr nglichen Vollansicht Die Ansicht wird verkleinert zur ckzukehren geben Sie Z auf Ihrer Tastatur ein oder doppelklicken Sie auf das Diagramm 7 Klicken Sie auf Datenpunkte um die Tabelle f r Einblendung der Tabelle f r das das ausgew hlte Intervalldatenprotokoll ausgew hlte Intervalldatenprotokoll anzuzeigen siehe nachstehende Abbildung 37 8 Um andere Gr en anzuzeigen klicken Sie auf Aktivierung der Anzeige ausgew hlter Neue Gr e n Aktivieren Sie die Kontrollk stchen der Gr en die Sie anzeigen m chten und klicken Sie auf bernehmen Die von jedem Ger t aufgezeichneten Daten werden auf einer Webseite in einem Zeitgang Diagrammformat dargestellt Das Zeitgang Diagramm ist f r die Anzeige der Daten vom letzten vollst ndigen Tag von der letzten vollst ndigen Woche vom letzten vollst ndigen Monat oder aller Daten vorkonfiguriert Energieparameter werden als kumulierte Werte aufgezeichnet aber als inkrementelle Werte auf der Basis von Intervallen angezeigt Alle anderen Parameter werden als aufgezeichneter Istwert protokolliert und angezeigt Abbildung 36 Diagramm des Intervalldatenprotokolls Intervalld
222. en der Erkennung doppelter IP Adressen Spannungsversorgungs Se Doppelte IP Adresse erkannt IStatus LED Boot Prozess Wiederher Das EGX kehrt zur voreingestellten Muster aus vier Blinkzeichen stellung der IP Adresse Subnetzmaske und und einer Pause Spannungsversorgung Gateway Adresse zur ck ARP Anfragen werden alle 15 Sekunden gesendet bis die IP Adresse verf gbar ist Sobald die IP Adresse verf gbar ist wird sie vom EGX verwendet Ethernet Verbindung erkannt Manuelle Das EGX beh lt seine vorherige Adressen nderung IP Adresse und zeigt eine Meldung an die darauf hinweist dass die IP Adresse bereits von einem anderen Ger t verwendet wird Erhalt einer ARP Anfrage R ckkehr zur im EGX Muster aus vier Blinkzeichen voreingestellten IP Adresse und einer Pause Subnetzmaske und Gateway Adresse wenn ein angeschlossenes Ger t vier ARP Anfragen bez glich der IP Adresse des EGX sendet Das EGX sendet alle 15 Sekunden ARP Anfragen bis die IP Adresse wieder verf gbar ist Sobald die IP Adresse verf gbar ist wird sie vom EGX verwendet Serielle Schnittstelle 1 Klicken Sie im Setup Men auf Serielle Einblendung der Seite Serielle Schnittstelle Schnittstelle 2 W hlen Sie die physische Schnittstelle Auswahl der Optionen f r die serielle den bertragungsmodus die Baudrate die Schnittstelle Parit t und die Antwort Zeit berschreitung aus siehe Tabelle 5 auf Seite 9 3 Klicken Si
223. enden Register Ger teliste aus Geben Sie die Startdatenadresse und die Anzahl der zu lesenden Register ein 3 W hlen Sie einen Datentyp aus Auswahl des entsprechenden Datentyps 4 Um die Art der Datenanzeige in der Spalte Auswahl der Art der Datenanzeige Wert zu ndern w hlen Sie Dezimal Hexadezimal Bin r oder ASCII aus 5 Klicken Sie auf Lesen Lesen der Ger teregister gem der ausgew hlten Konfiguration Tabelle 19 Einstellungen des EGX zum Lesen von Ger teregistern Option Beschreibung Werkeinstellung Geratebezeichnung Damit wird ein zu lesendes Ger t aus der Liste vorher hinzugef gter Ger te ausgew hlt Ein Ger t das nicht in der Ger teliste definiert ist kann durch Eingabe seiner lokalen ID gelesen werden Adresse lokale ID des auszulesenden Ger ts Spalte Wert Auflistung der f r ein Register gespeicherten Daten Die abgerufenen Werte h ngen vom Ger t ab das mit dem EGX verbunden ist Weitere Informationen ber gespeicherte Registerwerte finden Sie in den Unterlagen des verbundenen Ger ts Datentyp Auswahl von Halteregister Eingangsregister Halteregister Ausgangsspulen Eingangsspulen bzw Ger te ID Optionen Dezimal Legt fest wie Daten in der Spalte Wert angezeigt Dezimal Hexadezimal Bin r werden sollen bzw ASCII 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Diagnose Kommun
224. ene los encabezamientos dor de hora local Energ a aparente kVAh de las columnas para los datos Energ a real kWh Energ a reactiva kVARh registrados en las filas 8 y superiores Estas filas contienen los datos registrados riores 0 300 2008 10 09 14 15 00 1400738 219 1201962 707 647069 906 15 0 300 2008 10 09 14 20 00 1400758 260 1201980 725 647078 602 15 0 300 2008 10 09 14 25 00 1400778 198 1201998 661 647087 233 15 Si utiliza una aplicaci n de hoja de c lculo para ver el archivo CSV sus datos tendr n un aspecto similar al de la Figura 38 de la p gina 43 O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Supervision Figura 38 Registro de datos de intervalo abierto en una aplicaci n de hoja de calculo F A I B I C I D JE I F cman H m rt Gateway Name Gateway SN Gateway IP Address Gateway MAC Address Device Name Device Local ID Device Type Device Type Name Log Interval 21 EGX300 0 157 198 184 125 00 80 67 80 5B 61 Building Main 1 5 CM4000 5 3 4 Topic ID 1 Topic ID 2 Topic ID 3 5 1617 1621 1625 6 7 Error UTC Offset Minutes Local Time Stamp Energia aparente kVAh Energia activa kWh Energia react kYARh 8 0 360 02 12 2010 13 20 2708484 084 2436019 161 1160734 726 9 0 360 02 12 2010 13 25 2708509 192 2436042 802 1160743 04 10 0 360 02 12 2010 13 30 2708534 061 2436066 114 1160751 553 11 0 360 02
225. ent via FTP on each scheduled interval 4 Select Hourly Daily Weekly Monthly or Selects how often the data logs are Logging interval transported 5 Depending on which options you selected Selects when the data logs are transported in the previous step select the time of day day of the week and or the day of the month 6 Inthe Server IP Address text boxes enter Enters the address of the server transporting the address of the outgoing FTP server the data logs 0 0 0 0 to 255 255 255 255 NOTE Contact your network administrator if you do not know the address of the File Transfer Protocol FTP server 7 Inthe Server TCP Port text box enter the Enters the outgoing delivery port FTP server port Default 21 8 Inthe Directory text box enter the Allows you to enter directory information for the directory remote server 9 Enter your username and password in the Records your server login information text boxes 10 Enable the Passive check box Sets FTP file transfer mode to passive 11 Click Test to test the FTP parameters you Sends a test file to the FTP server and set or click Apply directory and or applies the FTP settings NOTE Clicking Test applies the log export FTP settings and transfers a test file and clicking Apply only applies the settings Figure 16 Device Log Export Page FTP Device Log Export Transport Disabled E Mail FTP O HTTP Incremental
226. er Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Setup Figure 7 Remote Device Connections Remote Device Connections D TTT 2 3 4 5 6 Y 8 9 ie Pao a FOR SS LOT JTE D A A er M g 169 254 0 30 169 254 0 40 169 254 0 50 169 254 0 60 2011 Schneider Electric All Rights Reserved 11 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 EGX Device List Before you begin keep in mind that you must not use serial slave addresses 1 or 16 in Automatic transmission mode on a daisy chain with mixed protocols for example a single daisy chain with some devices using PowerLogic protocol and others using Modbus RTU Jbus protocol Connecting Devices to an EGX Figure 8 and Figure 9 illustrate how devices can be connected to the EGX To add those devices to the Device List follow the steps in Device List Setup on page 13 Figure 8 Topology Serial Slave Devices Only Ethernet Connection EGX300 Web Pages EGX Serial Slave Devices Figure 9 Topology Serial Slave and Remote Devices Ethernet Connection EGX300 Web Pages EGX100 IP EGX300 IP address dd 169 254 0 28 1 69 254 0 75 RS485 connection Up to 16 remote IP connections RS485 connection are possible Es E ad La a As 1 E 7 LL VOTE y y j Remote Slave Devices Serial Slav
227. er Monat nach Tagen Aktueller Monat ber Vormonat nach Tagen Nach Wochen Vorquartal nach Wochen Aktuelles Quartal nach Wochen Aktuelles Quartal ber Vorquartal nach Wochen Zur ckliegende 13 Wochen nach Wochen Nach Monaten Vorjahr nach Monaten Aktuelles Jahr nach Monaten Aktuelles Jahr ber Vorjahr nach Monaten HINWEIS Bei dieser Option muss jede Ger tedatenprotokolldatei gen gend Kapazit t f r die Verlaufsdaten von zwei Jahren haben F r weitere Informationen siehe Intervalldatenaufzeichnung auf Seite 17 Zur ckliegende 12 Monate nach Monat 46 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Anzeigen einer Instrumententafel 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 berwachung Ma nahme Ergebnis Klicken Sie im berwachungsmen auf Anzeige des Instrumententafelmen s siehe Instrumententafeln Abbildung 41 Auswahl des Ger ts zur Anzeige von Daten W hlen Sie ein Ger t aus der Dropdown Liste Ger t aus HINWEIS Die Instrumententafel zeigt Daten eines Einzelger ts an W hlen Sie eine Gr e aus der Dropdown Auswahl der grafisch darzustellenden Gr e Liste Gr enbezeichnung aus HINWEIS Die Gr enauswahl ist auf inkrementelle Verbrauchsgr en des Ger ts beschr nkt Auswahl des Zeitbereichs der aufgezeichneten Daten f r die ausg
228. erden als aufgezeichneter Istwert protokolliert und angezeigt Abbildung 39 Setup Seite Mehrere Ger te Einzelgr e Ger te und Gr en ausw hlen Verf gbare Ger te Verf gbare Gr en Building Main Scheinenergie KVAh Building West Panel Wirkenergie kWh Building East Panel Blindenergie kVARh Building North Panel 2011 Schneider Electric Alle Rechte vorbehalten 45 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 berwachung 11 2011 Abbildung 40 Trendseite Mehrere Ger te Einzelgr e Wirkenergie kWh Letzter vollst ndiger Tag SA EE Building North Panel W Building East Panel 13 2010 02 16 06 00 00 2010 02 16 12 00 00 2010 02 16 18 00 00 2010 02 17 00 00 00 2010 02 1 W hlen Sie den Bereich der eingezoomt werden soll Bet tigen Sie die Z Taste oder f hren Sie einen Doppelklick aus um das Zoomen r ckg ngig zu machen Instrumententafeln Das EGX unterst tzt vier Kategorien von Instrumententafeln die zeitlich summierte Energieverbrauchsdaten anzeigen Die Instrumententafeln und ihre Teils tze sind in Tabelle 17 aufgelistet Tabelle 17 Instrumententafelarten Instrumententafel Teilsatz Nach Stunden Vortag nach Stunden Aktueller Tag nach Stunden Aktueller Tag ber Vortag nach Stunden Nach Tagen Vorwoche nach Tagen Aktuelle Woche nach Tagen Aktuelle Woche ber Vorwoche nach Tagen Vormonat nach Tagen Aktuell
229. erelle EGX prend en charge les types d authentification Plain Login CRAM MD5 et Digest MD5 Si vous avez coch l option Connexion au serveur M morise vos identifiants de SMTP via authentification saisissez votre nom connexion au serveur SMTP d utilisateur et votre mot de passe dans les zones de texte Cliquez sur Courrier lectronique de test pour envoyer Envoie un courrier lectronique un message test avec les param tres que vous avez de test et ou applique les d finis ou cliquez sur Appliquer param tres d exportation du REMARQUE Le bouton Courrier lectronique de test uMal par courrier lectronique valide les param tres d exportation du journal par courrier lectronique et envoie un courrier de test le bouton Appliquer valide uniquement les param tres Figure 15 Page Exporter le journal de l appareil par courrier lectronique Exporter le journal de l appareil Transport D sactiv Courrier lectronique O FTP O HTTP Incr mentale Planifier O Intervalle d enregistrement O Horaire Quotidien Hebdomadaire Mensuel Heure 00 00 FA Jour de la semaine Jour du mois 1 Ej Param tres du courrier lectronique De l adresse Aux adresses Adresse IP du serveur 0 0 0 0 Port TCP du serveur 25 Connexion au serveur SMTP via authentification Nom d utilisateur Mot de passe Expo
230. ert HINWEIS Wenn das Kontrollk stchen Inkrementell nicht aktiviert ist wird die gesamte Protokolldatei in jedem geplanten Intervall ber FTP bertragen 4 W hlen Sie St ndlich T glich W chentlich Festlegung wie oft Datenprotokolle Monatlich oder Aufzeichnungsintervall aus bertragen werden sollen 5 W hlen Sie je nach Auswahl der Optionen im Festlegung wann Datenprotokolle vorangegangenen Schritt die Tageszeit den bertragen werden sollen Wochentag und oder den Tag des Monats 6 Geben Sie in die Textfelder Server IP Adresse Eintrag der Adresse des Servers der die Adresse des Ausgangs FTP Servers 0 0 0 0 die Datenprotokolle bertr gt bis 255 255 255 255 ein HINWEIS Wenden Sie sich an Ihren Netzwerkadministrator wenn Sie die Adresse des FTP Servers nicht kennen 7 Geben Sie im Textfeld Server TCP Port die FTP Eingabe der Ausgangsschnittstelle Server Schnittstelle ein Werkeinstellung 21 8 Geben Sie im Textfeld Verzeichnis das Eingabe von Verzeichnisinformationen Verzeichnis ein f r den entfernten Server 9 Geben Sie in die Textfelder Ihren Benutzernamen Aufzeichnung Ihrer Server und das Kennwort ein Anmeldedaten 10 Aktivieren Sie das Kontrollk stchen Passiv Passiveinstellung des FTP Datei bertragungsmodus 11 Klicken Sie auf FTP pr fen um die von Ihnen bertragung einer Testdatei an den eingestellten FTP Parameter zu berpr fen oder FTP Server und das Verzeichnis klicken Sie auf
231. ert Max Mittelwert Building East Panel Gesartwrrkleistung KW 99 101 102 100 0 Building East Panel Gesamtscheinleistung kVA 101 102 103 101 6 Building North Panel Gesamtwrkleistung kW 100 101 103 101 5 Building North Panel Gesantscheinleistung kVA 113 114 116 1142 Die Seiten Ger teaufzeichnung enthalten grafische und tabellarische Darstellungen der ausgew hlten Ger teaufzeichnungsdaten Weitere Details zur Konfiguration der Ger teaufzeichnung finden Sie unter Ger teaufzeichnung auf Seite 17 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Einzelger teseiten 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 berwachung Einzelger teseiten enthalten grafische und tabellarische Darstellungen der Daten die von einem einzelnen Ger t aufgezeichnet wurden Klicken Sie im berwachungsmen auf Erweiterung der Baumansicht f r die Ger teaufzeichnung Anzeige der verf gbaren Auswahlm g lichkeiten f r die Ger teaufzeichnung 2 Klicken Sie unter Ger teaufzeichnung auf Erweiterung der Baumansicht zur Anzeige Einzelger teseiten der verf gbaren Ger te die Daten f r die Betrachtung aufgezeichnet haben 3 W hlen Sie ein Ger t aus der Liste Anzeige des Ger teprotokolls f r das Ger teaufzeichnung aus ausgew hlte Ger t 4 Um einen Datenbereich anzuzeigen w hlen Sie Auftragung des ausgew hlten d
232. ert die H ufigkeit mit der Daten aus den Ger ten in die normalen berwachungstabellenansichten ausgelesen werden Steuert wie oft eine Kommunikations pr fung durchgef hrt wird w hrend der Browser Echtzeitmesswerte in den normalen berwachungstabellenansichten anzeigt Mit dieser Funktion wird versucht alle au er Betrieb befindlichen Ger te automatisch wieder in Betrieb zu setzen Werkeinstellung Powerlogic EGX300 Startseite Schaltkreis bersicht Laststrom bersicht Strommittelwert bersicht Leistungs bersicht oder Energie bersicht Werkeinstellung Startseite 5 bis 60 Sekunden Werkeinstellung 5 Sekunden Deaktiviert 5 bis 30 Minuten Werkeinstellung 15 Minuten 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 PowerLogic Ethernet Gateway EGX300 Setup Anzeigbare Ger tetypen Pr fpfad 2011 Schneider Electric Alle Rechte vorbehalten Auf der Seite Anzeigbare Ger tetypen k nnen die Ger tetypen verwaltet werden die f r den Benutzer auf der Setup Webseite Ger teliste zur Auswahl stehen Da das EGX300 viele verschiedene Ger tetypen unterst tzt kann das Entfernen von Ger tetypen aus der Liste Verf gbare Ger te u U die Konfiguration der Setup Webseite Ger teliste vereinfachen 1 Klicken Sie im Setup Men auf Anzeigbare Einblendung der Seite Ger tetypen Anzeigbare Ger tetypen 2 W hlen Sie die Ger
233. erung der Ethernet und TCP IP HINWEIS Beim bernehmen von Einstellungen f r das ESA Anderungen auf die Seite Erweiterte Ethernet Einstellungen werden diese nderungen nicht auf der Seite Ethernet amp TCP IP gespeichert 4 Klicken Sie auf OK um die nderungen zu Das EGX startet neu best tigen und das EGX zur ckzusetzen Abbildung 4 Seite Erweiterte Ethernet Einstellungen Erweiterte Ethernet Einstellungen Time To Live 60 1 255 Hops TCP Keep Alive 30 Sekunden BootP Zeit berschreitung 15 Sekunden ARP Cache Timeout 15 Minuten FTP Server Aktiviert _ le FTP Verbindungsleerlaufzeit 30 Sekunden HTTP Verbindungsleerlaufzeit 4 Sekunden HTTP Port Nr 80 1 65535 Max Anzahl der HTTP Keep Alive Versuche 100 Modbus TCP IP Serververbindungen 32 y Modbus Broadcast Deaktiviert x Modbus TCP Proxyserver Aktiviert Timeout Modbus TCP IP Client 5 E Sekunden Timeout Modbus TCP IP Client Verbindung 10 y Sekunden Modbus TCP IP Server Verbindung Leerlaufzeit 0 Sekunden Standardwerte bernehmen 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Setup Tabelle 3 Erweiterte Ethernet Einstellungen des EGX G ltigkeitsdauer Legt die Anzahl der Router fest die ein TCP 1 bis 255 Hops Paket d
234. es Web Donn es en temps r el Lecture seule v Lecture seule v Lecture seule M Aucune Donn es du journal d appareil Lecture seule M Lecture seule v Lecture seule x Aucune R initialisations Lecture seule Lecture seule ly Lecture seule Aucune Statistiques Lecture seule iy Lecture seule aa Lecture seule M bal Aucune lv Lecture de registres d appareils Lecture seule w Lecture seule Lecture seule lv Aucune iv V rification des communications Lecture seule M Lecture seule v Lecture seule x Aucune v a A Journal de maintenance Lecture seule Lecture seule M Lecture seule M Aucune Coors cee Ethernet et TCP IP Lecture seule d v Lecture seule y Lecture seule x Aucune a Port s rie Lecture seule Lecture seule Lecture seule Aucune x Connexions d appareils distants Complet Complet Complet im Lecture seule x Liste des appareils Lecture seule Lecture seule w Lecture seule x Aucune x Journaux d appareil Lecture seule Lecture seule M Lecture seule Aucune v Exporter le journal de l appareil Lecture seule y Lecture seule lv Lecture seule x Aucune iy Liens vers la documentation Lecture seule M Lecture seule w Lecture seule ba Aucune bd Pr f rences Lecture seule Lecture seule Lecture seule v Aucune v device shtml Lecture seule w Lecture seu
235. es n meros de puerto est n reservados para otros protocolos de red y no pueden usarse 20 y 21 FTP y 502 Modbus TCP IP Puerto TCP utilizado para los mensajes HTTPS La EGX viene con un certificado autofirmado Para convertir la EGX en un servidor de plena confianza debe adquirir un certificado a una entidad emisora de certificados por ejemplo los servicios de autenticaci n VeriSign Para agregar instalar un certificado digital despl cese manualmente a la p gina de actualizaci n de certificados empleando la URL http x x x x update_certs_shtml donde x x x x es la direcci n IP de la EGX Se utiliza para especificar el numero maximo de mantenimientos de conexiones HTTP Se utiliza para especificar el numero de conexiones disponibles del servidor Modbus TCPIIP Determina c mo se tratan los mensajes TCP IP Modbus con ID de unidad de 0 en la subred serie Desactivado se ignoran todos los mensajes Activado se tratan todos los mensajes como difusiones a puertos serie sin que se espere una respuesta Activado con respuesta todos los mensajes se tratan como mensajes regulares a puerto serie para los que se espera una respuesta Parametro que determina si los mensajes Modbus TCP IP procedentes de clientes remotos se encaminan a dispositivos remotos Modbus TCP IP que est n definidos en la EGX Cantidad de tiempo que la EGX esperar a que un dispositivo remoto Modbus TCP IP responda a una solicitud Mo
236. es pour FTP voir Exportation par FTP page 21 Cr ez un dossier sur votre ordinateur par Cr e un dossier pour conserver les journaux exemple c journaux_egx de donn es de la passerelle EGX 2 Lancez l Explorateur Windows tapez ftp Ouvre la bo te de dialogue Connexion en tant et l adresse IP de la passerelle EGX dans la que barre d adresses ex ftp 169 254 0 10 puis appuyez sur Entr e 3 Tapez le nom d utilisateur Administrator et Ouvre une session FTP avec la passerelle le mot de passe correspondant dans les EGX et affiche les fichiers enregistr s dans la zones de texte appropri es puis cliquez sur passerelle Connexion 4 Ouvrez le r pertoire logging data de la Ouvre le r pertoire des journaux de donn es passerelle EGX sur la passerelle EGX 5 Copiez le journal et collez le dans le dossier Copie le journal dans votre dossier cr l tape 1 2011 Schneider Electric Tous droits r serv s 43 Passerelle Ethernet PowerLogic EGX300 Surveillance Obtention d un journal de donn es d intervalle par le biais du bouton Acc s aux donn es Obtention d un journal de donn es d intervalle par le biais d une requ te Web Microsoft Obtention d un journal de donn es d intervalle par courrier lectronique Obtention d un journal de donn es d intervalle par HTTP 44 63230 319 216B2 11 2011 Dans la page Web Journaux d appareil Une nouvelle fen
237. es retirer de l interface Web sans avoir a les supprimer de la passerelle EGX par le biais de la page Ajouter supprimer des pages Web Cette page est accessible depuis la page Acc s aux pages Web 1 Lancez l Explorateur Windows tapez ftp Ouvre la bo te de dialogue Connexion en tant suivi de l adresse IP de la passerelle EGX que ex ftp 169 254 0 10 dans la barre d adresses puis appuyez sur Entr e 2 Tapez le nom d utilisateur Administrator et Ouvre une session FTP avec la le mot de passe correspondant dans les passerelle EGX zones de texte appropri es puis cliquez sur Connexion 3 Ouvrez une autre fen tre de l Explorateur Copie le fichier dans le Presse papiers Windows localisez la page Web personnalis e que vous souhaitez envoyer la passerelle EGX cliquez dessus avec le bouton droit puis choisissez Copier 4 Revenez l Explorateur Windows de l EGX Ouvre le dossier dans lequel la page sera fen tre affich e l tape 1 puis ouvrez le stock e sur la passerelle EGX dossier dans lequel la page doit tre copi e www monitoring par exemple 5 Cliquez avec le bouton droit dans le volet Copie la page personnalis e sur la passerelle droit de la fen tre de l Explorateur Windows EGX et cliquez sur Coller REMARQUE Au lieu de copier coller le fichier vous pouvez le faire glisser vers PExplorateur Windows 6 Cliquez sur le bouton Fermer de la fen tre Ferme la fen tre de
238. esen k nnen wo Die Tabellenansicht Einzelger teseiten zeigt Grundmesswerte der ausgew hlten Ger te an Die Tabellenansicht bersichtsger teseiten zeigt bersichten ber ein oder mehrere ausgew hlte Ger te an Die Ansicht Trendverfolgungsseite zeigt grafisch und tabellarisch die Echtzeit Trendverfolgung von Gr en an die mehrere Ger te gemeinsam haben Die Einzelger teseiten zeigen grafische und tabellarische Trendaufzeichnungen in benutzerdefinierbaren Gr en f r ausgew hlte Ger te an Die bersichtsger teseiten zeigen grafische Trendaufzeichnungen mehrerer Ger te mit einer gemeinsamen Gr e an Die Instrumententafeln enthalten grafische und tabellarische Darstellungen von zeitlich summierten Energieverbrauchsdaten aller Ger te f r die die Datenaufzeichnung aktiviert ist gt do gt gt o o N Die Seite Systemzugangspunkt zeigt EGX300 Ger te und andere Systemger te im Netzwerk an auf die vom jeweiligen EGX300 zugegriffen werden kann Jede Zeile ist ein Hyperlink zur EGX300 Anmeldeseite PowerLogic Ethernet Gateway EGX300 63230 319 216B2 EGX Benutzeroberflache berblick 11 2011 Tabelle 1 EGX Seiten EGX Webseite Beschreibung giene Unterlagen Unterlagen Zugriff auf relevante EGX Unterlagen und vom Benutzer 49 konfigurierte Unterlagenlinks Sorgt f r die Ausf hrung von R ckstellungen die f r das 4 Ger t festgelegt sind und zeig
239. esents the maximum number of connections that were active at any given moment Inbound Read Messages A counter that increments each time a read request message is received Inbound Write Messages A counter that increments each time a write request message is received Outbound Reply Messages A counter that increments each time a reply message is sent Frames Sent A counter that increments each time a frame is sent Frames Received A counter that increments each time a frame is received Protocol Errors A counter that increments each time an ill formed message is received Click the link for additional detailed information 51 PowerLogic Ethernet Gateway EGX300 Diagnostics 52 63230 319 216B2 11 2011 A counter that increments each time a request message is sent without receiving a corresponding response message within the allowed time Timeouts are typically the result of configuration errors or a non responsive device A counter that increments each time the connection is lost Exceptions Received A counter that increments each time an exception is received A counter that increments each time a read request message is sent Outbound Write Message A counter that increments each time a write request message is sent Inbound Reply Messages A counter that increments each time a reply message is received Details A detailed table providing remote and serial statistics per device Ser
240. eses 46 O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Supervision Visualizaci n de un panel de instrumentos Accion Resultado En el menu Supervisi n haga clic en Panel Muestra el men del panel de instrumentos de instrumentos consulte la Figura 41 Seleccione un dispositivo en la lista Selecciona el dispositivo para mostrar sus desplegable Dispositivo datos NOTA El panel de instrumentos muestra los datos de un solo dispositivo Seleccione un tema en la lista desplegable Selecciona los temas que se mostrar n Nombre tema gr ficamente NOTA Los temas est n limitados a los temas de consumo incremental proporcionados por el dispositivo Seleccione los par metros de tiempo en la Selecciona el rango de tiempo de los datos lista desplegable Hora registrados correspondientes al tema seleccionado Haga clic en Aplicar Abre el panel de instrumentos seleccionado Figura 41 Men Panel de instrumentos Panel de instrumentos Dispositivo Pmssso 1032 Nombre tema Energ a activa kWh Hora D a actual con d a anterior por horas Aplicar Los datos de cada panel de instrumentos se muestran en una p gina web en formato de gr fico de barras Al desplazar el puntero del rat n sobre una barra del gr fico se muestra el valor del punto de datos del intervalo seleccionado Figura 42
241. et Definit les param tres Ethernet avanc s avanc s voir le Tableau 3 page 7 pour les options disponibles Cliquez sur Valeurs par d faut pour s lectionner les valeurs par d faut pour toutes les options 3 Cliquez sur Appliquer Met jour les param tres Ethernet et TCP IP REMARQUE La modification des de la passerelle EGX donn es de la page Param tres Ethernet avanc s ne valide aucune des modifications apport es la page Ethernet et TCP IP 4 Cliquez sur OK pour valider les La passerelle EGX red marre modifications et r initialiser la passerelle EGX Figure 4 Page Param tres Ethernet avanc s Param tres Ethernet avanc s Dur e de vie 60 1 255 Sauts Maintien de la connexion TCP 30 Secondes D lai d attente BootP 15 Secondes D lai d attente du cache ARP 15 Minutes Serveur FTP Activ D lai d inactivit de la connexion FTP 120 __ Secondes D lai d inactivit de la connexion HTTP 6 Secondes Num ro de port HTTP 80 1 65535 Numero de port HTTPS 0 1 65535 Tentatives de maintien de la connexion HTTP 100 Connexions serveur Modbus TCP IP 32 Diffusion Modbus D sactiv i Proxy Modbus TCP Active al D lai d attente du client Modbus TCP IP 5 El Secondes D lai d attente de la connexion client Modbus TCP IP 2 Secondes D lai d inactivit de la connexion serveur Modbus TCP IP 0 _ Secondes
242. etwork 1 65535 seconds default 300 seconds 35 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 6 Hold Time This is the period of time that Hello messages sent by this EGX300 should be held by recipients before considering this EGX300 unavailable From 2 to 65535 seconds default 600 seconds 7 Multicast Time to Live You can control how wide an area of the network will be included to discover other devices This is controlled by the number of times that the multicast is allowed to be forwarded to others The range of permitted router hops is 1 255 Default 1 8 Community EGX300s in a group can be divided into communities EGX300s with the same group IP address and community number are able to discover each other Setting the community number to 0 allows an EGX300 to discover all EGX300s with the same group IP address without regard to the community setting Default 0 9 Defaults Apply Click Apply to save your entries click Defaults to return to the defaults that are listed Figure 29 System Access Point Setup Page System Access Point Enabled F UDP Port 59 1 65535 Group IP Address 224 fo fi RP Hello Time 30 1 65535 Seconds Hold Time 60 2 65535 Seconds Multicast Time to Live Rh 1 255 Hops Community 0 0 65535 Defaults Apply 36 2011 Schneider Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway
243. eur r seau d acc der distance la passerelle EGX au moyen d un gestionnaire SNMP et d afficher le statut r seau et les diagnostics de la passerelle au format MIBII 1 Dans le menu Configuration cliquez sur Ouvre la page Param tres SNMP Param tres SNMP 2 S lectionnez l option Activer SNMP pour Active le protocole SNMP activer le protocole SNMP 3 Saisissez le contact syst me le nom et Saisit les informations SNMP du syst me l emplacement du syst me le nom de la et les noms d acc s des communaut s communaut en lecture seule et le nom de la communaut en lecture criture 4 Cliquez sur Appliquer Enregistre la configuration SNMP Figure 20 Page Param tres SNMP Param tres SNMP Activer SNMP M OO Contact systeme Admin Nom systeme John Smith Emplacement syst me Office 1 Nom de communaut lecture seule public Nom de communaut lecture criture private Cette fonction permet l administrateur de d finir le niveau d acc s des clients Modbus TCP IP aux appareils locaux ou distants connect s la passerelle EGX REMARQUE Il existe une adresse anonyme Modbus TCP IP LEE qu il est possible de configurer en lecture seule ou sans droit d acc s La configuration en Lecture seule permet n importe quel client Modbus TCP IP ne figurant pas dans la liste filtr e d acc der en lecture seule aux appareils s rie esclave La configuration sans droit d acc
244. eurs pour le calcul de REMARQUE Seules les grandeurs communes tous RIRES les appareils s lectionn s sont disponibles pour le calcul de tendance Le nombre maximum de grandeurs prendre en compte d pend du nombre d appareils s lectionn s Le produit des appareils et grandeurs s lectionn s doit tre gal ou inf rieur 8 6 Cliquez sur Suivant pour ouvrir la page d affichage La page d affichage Calcul de Calcul de tendance en temps r el tendance en temps r el s ouvre 7 Pour configurer les param tres de tendance poursuivez Permet de d finir les param tres la proc dure du tableau suivant en vous reportant la de calcul de tendance Figure 35 Figure 34 S lectionner les appareils et les grandeurs S lectionner les appareils et les grandeurs Appareils disponibles Grandeurs disponibles Building Main Courant 1 Building West Panel Courant 2 Building East Panel Courant 3 Building North Panel Moyenne courant Tension 1 2 Tension 2 3 Tension 3 1 Tension moyenne L L Tension 1 N Tension 2 N Tension 3 N Tension moyenne L N Puissance r active totale kVAR Puissance apparente totale kVA Val moyenne du courant 1 Val moyenne du courant 2 Val moyenne du courant 3 Fr quence Hz m 39 Passerelle Ethernet PowerLogic EGX300 Surveillance Journaux d appareil 40 Selectionnez le type de tendance Absolue ou Relative REMARQUE En mode Absolue l axe des abscis
245. evice list 13 EGX 5 single device pages 37 41 SNMP parameters setup 25 statistics 50 interpreting 51 summary device pages 38 45 supported device types 60 supported ethernet protocols 59 Syslog audit trails 34 system access point links to other EGX300s 48 setup 35 T TCP IP settings 5 time synchronization network 24 trending 39 trusted certificate HTTPS port number 7 U user accounts setup 28 user interface EGX 3 V viewable device types 33 viewing real time data and trends 37 WwW web pages adding removing from the web interface 31 setup 29 custom 30 63 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Index 11 2011 64 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 User Guide Schneider Electric PowerLogic is a trademark of Schneider Electric Other trademarks are the property of their 295 Tech Park Drive Suite 100 respective owners La Vergne TN 37086 USA For technical support 2 a 4 se de Global PMC Tech support schneider electric com Electrical equipment should be installed operated serviced and maintained only by qualified 00 1 250 544 3010 personnel No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material Contact your local Schneider Electric sales representative for assistance or go to www schneider electric com 63230 319 216B2 11 2011 replaces 63230 319 216B1 dated 08 20
246. ew hlte Gr e W hlen Sie die Zeitparameter aus der Dropdown Liste Uhrzeit aus Klicken Sie auf bernehmen Anzeige der ausgew hlten Instrumententafel Instrumententafeln Ger t PM6360 ID32 Gr enbezeichnung Wirkenergie kWh Uhrzeit Aktueller Tag ber Vortag nach Stunden bernehmen Die Daten jeder Instrumententafel werden als Balkendiagramme auf einer Webseite angezeigt Wenn Sie mit dem Mauszeiger ber einen Balken im Diagramm gehen wird der Datenpunktwert f r das ausgew hlte Intervall angezeigt Abbildung 42 Abbildung 42 Instrumententafeldiagramm PM5350 ID32 Wirkenergie kWh Aktueller Tag ber Vortag nach Stunden Aktueller Ta 1 1 2 4 5 1 Abbildung 43 Instrumententafeltabelle PM5350 ID32 Wirkenergie kWh Aktueller Tag ber Vortag nach Stunden Tue Nov 22 15 40 00 CST 2011 Tue Nov 22 16 00 00 CST 2011 Tue Nov 22 17 00 00 CST 2011 Tue Nov 22 18 00 00 CST 2011 Tue Nov 22 19 00 00 CST 2011 Tue Nov 22 20 00 00 CST 2011 Tue Nov 22 21 00 00 CST 2011 Tue Nov 22 16 00 00 CST 2011 Tue Nov 22 17 00 00 CST 2011 Tue Nov 22 18 00 00 CST 2011 Tue Nov 22 19 00 00 CST 2011 Tue Nov 22 20 00 00 CST 2011 Tue Nov 22 21 00 00 CST 2011 Tue Nov 22 22 00 00 CST 2011 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 berwachung 11 2011 Sie k nnen Daten einer Instrumententafel wie nachstehend beschrieben in einer Tabellenkalkula
247. ez mettre niveau le logiciel embarqu firmware de la passerelle EGX au moyen du protocole FTP File Transfer Protocol Rendez vous sur le site www powerlogic com ou consultez votre repr sentant local pour obtenir la derni re mise jour du logiciel embarqu La passerelle EGX comprend deux composants de logiciel embarqu le composant binaire ex cutable et le composant image de fichier 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Logiciel embarqu firmware Version du composant binaire ex cutable du 1 Ouvrez le navigateur Internet et Ouvre la page d accueil EGX connectez vous a la passerelle EGX 2 Recherchez la version du logiciel D termine la version du logiciel embarqu de la embarqu dans le coin inf rieur gauche de passerelle EGX la page REMARQUE Si vous avez r cemment mis jour le logiciel embarqu appuyez Sur la touche F5 pour actualiser la page et afficher le nouveau num ro de version 3 Vous pouvez galement s lectionner D termine galement la version du logiciel Diagnostics gt Statistiques pour embarqu de la passerelle EGX rechercher la version du logiciel embarqu dans la section Informations sur la passerelle Version du composant image de fichier de 1 Lancez l Explorateur Windows tapez ftp Ouvre la bo te de dialogue Connexion en tant et l adresse IP de la passerelle EGX dans la que bar
248. f der Setup Seite auf Ger teprotokollexport Einblendung der Seite f r den Ger teprotokollexport 2 W hlen Sie E Mail als bertragungsart Anzeige der Exportoptionen f r das Ger teprotokoll ber E Mail 3 Aktivieren Sie das Kontrollk stchen Inkrementell HINWEIS Wenn die bertragung St ndlich oder zum Aufzeichnungsintervall geplant ist wird das Kontrollk stchen Inkrementell automatisch aktiviert HINWEIS Wenn das Kontrollk stchen Inkrementell nicht aktiviert ist wird die gesamte Protokolldatei in jedem geplanten Intervall ber einen E Mail Anhang bertragen 4 W hlen Sie St ndlich T glich W chentlich Monatlich oder Aufzeichnungsintervall aus Hiermit werden nur neue seit dem letzten erfolgreichen Datenexport aufgezeichnete Intervalldaten ausgew hlt Festlegung wie oft Datenprotokolle bertragen werden sollen 19 PowerLogic Ethernet Gateway EGX300 Setup 20 5 W hlen Sie je nach Auswahl der Optionen im vorangegangenen Schritt die Tageszeit den Wochentag und oder den Tag des Monats Geben Sie in das Textfeld Von Adresse die E Mail Adresse der Person ein die das Ger t verwaltet HINWEIS Eine Absenderadresse ist notwendig weil die meisten SMTP Server sie verlangen Geben Sie in die Textfelder Zu Adresse die E Mail Adressen max 5 der Empf nger der Datenprotokolle ein eine Adresse pro Textfeld Geben Sie in die Textfelder Server IP Adresse d
249. finden Sie unter Ger teaufzeichnung auf Seite 40 HINWEIS F r die Aktivierung der Ger teaufzeichnung muss im Dropdown Fenster Aufzeichnungsintervall ein Zeitwert ausgew hlt werden Es wird empfohlen die Aufzeichnungsfunktion w hrend der Konfiguration eines Ger ts zu deaktivieren Beachten Sie dazu Abbildung 13 auf Seite 18 und deaktivieren Sie das Kontrollk stchen Protokollierung f r das ausgew hlte Ger t 17 PowerLogic Ethernet Gateway EGX300 Setup Aufzuzeichnende Gr en 18 63230 319 216B2 11 2011 Klicken Sie im Setup Men auf Einblendung der Seite f r die Ger teaufzeichnung Ger teaufzeichnung siehe Abbildung 13 2 Beachten Sie Abbildung 13 und aktivieren Sie die Auswahl der zu protokollierenden Option Protokollierung bei den Ger ten die Sie Ger te protokollieren m chten Umalle Ger te auszuw hlen klicken Sie auf Alle ausw hlen und anschlie end auf bernehmen Um die Auswahl aller Ger te aufzuheben klicken Sie auf L schen und anschlie end auf bernehmen 3 W hlen Sie das Aufzeichnungsintervall aus Auswahl des Aufzeichnungsintervalls f r die ausgew hlten Ger te 4 Klicken Sie auf bernehmen Aktualisierung der EGX Einstellungen f r die Ger teaufzeichnung OPTIONEN Um den Aufzeichnungsinhalt anzupassen aktivieren Sie Damit werden die aufzuzeichnenden die Ger teaufzeichnung und f hren Sie anschlie end Ger tegr en ausgew hlt Danach fol
250. g FTP Deleting Web Pages Using FTP 30 63230 319 216B2 11 2011 Custom web pages and other file types can be transferred from your computer to the EGX via FTP Files sent by FTP to the www monitoring www maintenance or www control directories with extensions of htm html or shtml will be automatically secured Each folder has a corresponding link on the menu bar in the web interface When the link is clicked on the menu bar the web pages you added will appear in the menu on the left side of the browser window under Custom Pages NOTE You cannot create new folders inside of the Monitoring Control or Maintenance folders After custom web pages or other files have been transferred to the EGX with FTP they can be added and removed from the web interface without removing them from the EGX by using the Add Remove Web Pages page This page is opened from the Web Page Access page Launch Windows Explorer type ftp and the IP address of the EGX for example ftp 169 254 0 10 in the Address text box then press Enter 2 Type the user name Administrator and the administrator password in the text boxes then click Log On 3 Open a new Windows Explorer window locate the custom web page you want to send to the EGX right click it then click Copy 4 Switch back to the EGX Windows Explorer window you opened in Step 1 then open the folder where the web page will be copied for example www monitoring 5 Righ
251. g of 0 disables this setting BootP Timeout Used to specify how long the EGX will wait for 0 to 60 seconds a BootP server to assign its IP address The Default 15 seconds default IP address is used after timeout if no IP address is assigned ARP Cache Timeout Used to specify how long entries in the o 65 000 minutes Address Resolution Protocol ARP table are Default 15 minutes kept FTP Server Controls whether the FTP server initializes Disabled or Enabled during startup Default Enabled FTP Connection Idle A timer that closes the FTP connection after a 30 to 900 seconds Time specified amount of idle time Default 120 seconds HTTP Connection Idle A timer that closes the HTTP connection after 0 to 65 000 seconds Time a specified amount of idle time Default 4 seconds HTTP Port Number The TCP port used for HTTP messages The 0 to 65 000 following port numbers are reserved for other Default 80 network protocols and cannot be used 20 0 disables HTTP port and 21 FTP and 502 Modbus TCP IP HTTPS Port Number The TCP port used for HTTPS messages 1 to 65 000 The EGX comes with a self signed certificate Default 443 To make the EGX a fully trusted server you 0 disables HTTPS port must acquire a certificate from a Certificate Authority e g VeriSign Authentication Services To add install a digital certificate manually navigate to the certificate update page using the URL http x x x x update_certs_shtml
252. gende Schritte aus W hlen Sie ein Aufzeichnungsintervall ungleich null erfolgt die R ckkehr zur Seite Ger teaufzeichnung aus und deaktivieren Sie das jeweilige HINWEIS Wenn Sie die Kontrollk stchen Ger teaufzeichnung des Ger ts Standardgr en ndern die f r Klicken Sie f r das Ger t das Sie konfigurieren ein Ger t aufgezeichnet werden m chten unter Anpassen auf Gr en ee Beachten Sie Abbildung 14 und aktivieren Sie die Spalte Anpassen f r dieses Gr en die Sie aufzeichnen m chten dabas Um alle Gr en auszuw hlen klicken Sie auf Alle ausw hlen und anschlie end auf bernehmen Um die Auswahl aller Gr en aufzuheben klicken bereits aktiven Ger teprotokolls werden alle vorher aufgezeich neten Daten f r dieses Ger t Sie auf L schen und anschlie end auf gel scht Bei Bedarf sollten die bernehmen Daten vor den nderungen aus Um die Standardgr en auszuw hlen klicken Sie dem EGX abgerufen werden auf Standardwerte unten im Bildschirm Um ein Datenprotokoll zu l schen aktivieren Sie Daten Auswahl der zu l schenden l schen f r die Datenprotokolle die Sie l schen m chten Datenprotokolle 1 Um alle Ger te auszuw hlen klicken Sie auf Alle HINWEIS Damit ein ausw hlen und anschlie end auf bernehmen Datenprotokoll gel scht werden 2 Um die Auswahl aller Ger te aufzuheben klicken Sie kann darf das Kontrollk stchen auf L schen und anschlie e
253. ges Web de l EGX300 EGX100 Adresse IP 169 254 0 28 ons IP 169 254 0 75 er Connexion RS 485 16 connexions IP distantes Connexion RS 485 sont possibles a e fl wi 3 Appareils esclaves distants Appareils esclaves s rie 12 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Configuration Configuration de la liste des appareils Dans le menu Configuration cliquez sur Ouvre la page Liste des appareils Voir Liste des appareils Figure 10 pour les connexions locales uniquement Figure 11 si des connexions distantes sont disponibles 2 Vous pouvez utiliser la d tection des Ouvre la page D tection des appareils pour appareils pour d tecter les appareils d tecter tous les appareils connect s connect s localement voir D tection des localement appareils page 15 puis passer a l tape 3 pour configurer les appareils distants si n cessaire 3 Reportez vous la Figure 11 page 14 et S lectionne le nombre d emplacements s lectionnez le nombre d appareils affichables qui peuvent servir a d finir des affichables 1 a 64 appareils connect s a la passerelle EGX 4 S lectionnez la Connexion dans la liste S lectionne la connexion d roulante 5 S lectionnez le Type d appareil dans la Selectionne le type d appareil liste deroulante 6 Dans la zone de texte No
254. gs This configuration parameter can only be changed if data logging is disabled for the device being updated See Device Logging on page 17 Figure 10 Device List Page Device List Number of Viewable Devices 8 x Device Type Device Name Local ID PM800 y PM800_Bldgl_Feederl 3 CM4000 CM4_Bldg1_Main1 4 CM2000 y CM2_Bldg2_Feeder2 5 PM9c x PM9c_Bldg2_Feeder2 6 Sepam 2000 Sepam2_Bldg2_CB_1 7 Sepam Series 40 Sepam4_Bldgi_CB_2 8 Model98 modbus Model98_Bldg1_Switchgear1 9 Modbus Mi 2011 Schneider Electric All Rights Reserved 13 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Figure 11 Device List Page with Remote Connections Supported Device List Number of Viewable Devices ls Y Connection Device Type Device Name Local ID Remote ID Building Main Building West Panel Building East Panel A w Building North Panel Serial Port 9 Modbus a g Serial Port Modbus a SerialPort Y Modbus a serial Port Y Modbus g Discover Table 7 Device List Settings Description Setting Number of Viewable Selects the number of devices to be 1 to 64 displayed Default 8 Connection Selects the connection site Serial Port or IP Address Default Serial Port Device Type Selects the device type to appear in the list Range of supported devices Device Name Allows you to name individual devices E You must define the Lo
255. h Engineering ly Deutsch hl Administrators M Deutsch Ea Operations FA Deutsch Administrators Deutsch E M Administrators M Englisch Administrators hd Spanisch Bd Administrators x Franz sisch x Maintenance y Deutsch v Maintenance v Deutsch Maintenance Deutsch y Maintenance m Deutsch x Deutsch 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Webseitenzugriff 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Setup Klicken Sie im Setup Men auf Webseitenzugriff 2 W hlen Sie die Zugriffsberechtigung Keine Schreibgesch tzt oder Vollst ndig aus die jede Benutzergruppe auf die Webseiten haben soll 3 Um einem Gast den Zugriff auf die Webseite zu erm glichen w hlen Sie in der Spalte Guest die Einblendung der Seite Webseitenzugriff Zugriffsberechtigung Schreibgesch tzt aus HINWEIS Wenn f r die Gruppe Guest die Zugriffsberechtigung Schreibgesch tzt eingestellt ist kann als Zugriffsberechtigung f r die anderen Gruppen nur Schreibgesch tzt oder Vollst ndig ausgew hlt werden 4 Wiederholen Sie die Schritte 2 und 3 f r die Optionen in jedem Abschnitt 5 Klicken Sie auf bernehmen Speicherung der Kennworteinstellungen Tabelle 12 Gruppenzugriff Vollst ndiger Zugriff auf alle Webseiten HINWEIS Aus Systems
256. h rique s lectionn REMARQUE Seules les grandeurs communes tous les appareils s lectionn s sont disponibles 6 S lectionnez Suivant Ouvre la page de calcul de tendance Plusieurs appareils une seule grandeur 7 Maintenez le bouton gauche de la souris Agrandit la partie du graphique s lectionn e enfonc et tracez une zone de s lection sur la partie du graphique agrandir 8 Pour revenir l affichage d origine L affichage r tr cit appuyez sur la touche Z du clavier ou double cliquez sur le graphique La grandeur enregistr e pour les appareils s lectionn s s affiche dans une page Web sous forme de graphique temporel Ce graphique est pr configur pour afficher les donn es de la derni re journ e compl te de la derni re semaine compl te du dernier mois complet ou toutes les donn es Les param tres d nergie sont affich s sous forme de valeurs incr mentales par intervalle Tous les autres param tres sont enregistr s et affich s comme la valeur r elle enregistr e Figure 39 Page de configuration Plusieurs appareils une seule grandeur S lectionner les appareils et les grandeurs Appareils disponibles Grandeurs disponibles Building Main nergie apparente kVAh Building West Panel Energie active kWh Building East Panel Energie r active KVARh 2011 Schneider Electric Tous droits r serv s 45 Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Surveilla
257. haque appareil s affichent dans une page Web sous forme d un graphique temporel Ce graphique est pr configur pour afficher les donn es de la derni re journ e compl te de la derni re semaine compl te du dernier mois complet ou toutes les donn es Les param tres d nergie sont enregistr s comme valeurs cumul es mais affich s sous forme de valeurs incr mentales par intervalle Tous les autres param tres sont enregistr s et affich s comme la valeur r elle enregistr e Figure 36 Graphique du journal de donn es d intervalle Journal de donn es d intervalle Building North Panel PM800 Derni re semaine compl te E _Nowelle s grandeur s __Acces aux donn es M nergie apparente kVAh 16 2010 02 13 00 00 00 2010 02 15 00 00 00 2010 02 17 00 00 00 2010 02 19 00 00 00 S lectionnez la zone agrandir Appuyez sur Z ou double cliquez pour annuler le zoom Figure 37 Tableau des acc s aux donn es du journal d intervalle Erreur Horodatage nergie livr kWh Energie re ue kWh Energie livr KVARh 0 2009 01 08 19 05 00 348 0 150 0 0 2009 01 08 18 40 00 348 0 150 0 0 2009 01 08 18 45 00 348 0 150 0 0 2009 01 08 18 50 00 348 0 150 0 0 2009 01 08 18 55 00 348 0 150 0 0 2009 01 08 19 00 00 348 0 150 0 0 2009 01 08 19 05 00 348 0 150 0 2011 Schneider Electric Tous droits r serv s 41 Passerelle Ethernet PowerLogic EGX300 Surveillance Obtention d un journ
258. hnitt Abrufen eines Intervalldatenprotokolls mit FTP auf Seite 43 aus Die Dateien haben das Format Ger tename Lokale ID csv wobei Ger tename der dem Slave Gerat zugewiesene Name und Lokale ID die ihm zugewiesene lokale ID Nummer ist Beispielsweise w rde ein Ger t mit der Bezeichnung Building 1 Utility Entrance mit der lokalen ID 3 eine Datei mit dem Namen Building 1 Utility Entrance_3 csv erzeugen Werden Protokolldateien exportiert werden das Datum und die Uhrzeit im folgenden Format an den Dateinamen angeh ngt JJJJMMTTSSMMSS Beispiel Building 1 Utility Entrance_3_20100218115216 csv Damit wird angezeigt dass die Datei am 18 Februar 2010 um 11 52 16 Uhr exportiert wurde Die Daten werden in folgendem Format aufgezeichnet siehe Abbildung 38 auf Seite 43 Tabelle 16 Intervalldaten Protokollformat Zeile Daten im CSV Format Beschreibung 1 BOM Gateway Bezeichnung Diese Zeile enth lt die Spalten berschriften f r Gateway SN Gateway Adresse die Daten in Zeile 2 Ger tebezeichnung lokale Ger te ID Ger tetypbezeichnung Aufzeich nungsintervall HINWEIS BOM Die ersten drei Bytes der Datei sind von einer 3 Zeichen BOM Byte Order Mark belegt UTF 8 Codierung EGX300SD 23227 157 198 184 116 Diese Zeile enth lt die Daten ber das EGX und Building 1 Utility Entrance 3 das protokollierte Ger t CM4000 15 Gr en ID 1 Gr en ID 2 Diese Ze
259. hnungskapazit t jeder Datenprotokolldatei ist unterschiedlich und h ngt vom ausgew hlten Aufzeichnungsintervall ab Die Aufzeichnungskapazit t jeder Datenprotokolldatei kann durch Division der maximal m glichen Anzahl von Aufzeichnungsintervallen die eine Datenprotokolldatei enthalten kann 171 072 durch das Produkt aus der Anzahl der aufgezeichneten Gr en und den pro Tag aufgezeichneten Intervallen berechnet werden Protokolldateikapazit t Intervalle max Gr en pro Intervall pro Tag aufgezeichnete Intervalle Beispiel Die Aufzeichnungskapazit t f r ein Ger tedatenprotokoll mit Aufzeichnung von drei Gr en alle 10 Minuten w rde wie folgt bestimmt Pro Tag aufgezeichnete Intervalle Minuten pro Tag Aufzeichnungsintervalle in Minuten 1440 10 144 Intervalle Protokolldateikapazit t maximal m gliche Intervalle aufgezeichnete Gr en pro Intervall pro Tag aufgezeichnete Intervalle 171072 3 144 396 Tage Die Aufzeichnungskapazit t wird dynamisch berechnet und auf der Gr enauswahlseite f r Beispiele siehe Tabelle 9 angezeigt Tabelle 9 Beispiele f r Aufzeichnungsintervalle Aufzeichnungskapazit t in Tagen f r bestimmte Gr en Aufzeichnungsintervalle E je ar lt F r jedes Ger t in der Ger teliste kann die Aufzeichnung separat aktiviert werden Die aufzuzeichnenden Gr en sind f r jedes Ger t eindeutig Informationen ber die Anzeige der Intervalldatenprotokolle
260. hos 39 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Supervision 11 2011 Seleccione la tendencia Absoluto o Relativo Selecciona el modo de grafico NOTA Absoluto redibuja el eje X del grafico despu s de cada muestreo y lo rellena con todos los datos recopilados desde el inicio de la tendencia Relativo actualiza el grafico con los datos mas recientes despu s de cada muestreo y mantiene el eje X constante para mostrar el tiempo general de la tendencia seleccionado Seleccione un tiempo de tendencia comprendido entre 1 Selecciona la duraci n de la y 15 minutos Esta ser la duraci n de la tendencia tendencia NOTA Los muestreos de datos se toman lo m s r pido posible pero el proceso puede requerir m s tiempo dependiendo de la carga de comunicaciones en la subred serie en los dispositivos remotos o en ambos Seleccione Iniciar muestreo para iniciar la generaci n de Inicia la generaci n de tendencias de los temas de los dispositivos tendencias seleccionados NOTA Para detener la generaci n de tendencias antes de que transcurra el tiempo de tendencia haga clic en Detener muestreo Si pulsa Iniciar muestreo despu s de detener el muestreo se iniciar una nueva tendencia Pulse Puntos de datos para visualizar un registro de Muestra un registro de todos todos los temas muestreados que quedaron registrados los valores de los temas durante el tiempo de tendencia muestreados durante la NOTA Despu s
261. i l appareil offre cette fonction Par exemple si le p riph rique ne prend pas en charge la valeur Min Max pour Date heure de la derni re r initialisation la valeur Min Max n appara t pas ici 49 Passerelle Ethernet PowerLogic EGX300 Diagnostics DIAGNOSTICS Statistiques 63230 319 216B2 11 2011 Pour acc der aux liens de la page Web Diagnostics cliquez sur Diagnostics dans la barre de menus EGX Cette page affiche les mesures cumul es depuis la derni re activation de la passerelle EGX En cas de perte de l alimentation de la passerelle EGX de r initialisation de l appareil suite une modification de la configuration ou autre v nement toutes les valeurs cumul es sont remises z ro 1 Dans le menu Diagnostics cliquez sur Ouvre la page Statistiques voir Figure 47 ci Statistiques dessous 2 Affichez les donn es Voir Interpr tation des statistiques ci dessous 3 Cliquez sur R initialiser Remet z ro les donn es de diagnostic de la passerelle EGX Figure 47 Page Statistiques Heure d amor age 2010 02 15 12 20 02 Etat de liaison Trames transmises avec succ s Collisions Exc s de collisions Trames re ues avec succ s Erreurs CRC Erreurs d alignement Longueur de trame excessive Longueur de trame insuffisante 100BaseTx FD 11345 0 0 92909 0 0 0 0 A Statistiques Heure actuelle 2010 02 16 06 24 36 Serveur Trame
262. ial Port Frames Sent A counter that increments each time a frame is sent Frames Received A counter that increments each time a frame is received CRC Errors A counter that increments each time a message is received that has a CRC that does not match what is calculated Typically the result of wiring issues A counter that increments each time an ill formed message is received A counter that increments each time a request message is sent without receiving a corresponding response message within the allowed time Timeouts are typically the result of configuration errors or a non responsive device Exceptions Received A counter that increments each time an exception is received Outbound Read Messages A counter that increments each time a read request message is sent Outbound Write Messages A counter that increments each time a write request message is sent Inbound Read Messages A counter that increments each time a read request message is received Inbound Write Messages A counter that increments each time a write request message is received Details A detailed table providing serial and remote statistics per device HTTP Server Frames Sent A counter that increments each time a frame is sent Frames Received A counter that increments each time a frame is received Active Connections A status value that represents the number of connections that are active at the moment the diagnostics page is refreshed
263. ic Alle Rechte vorbehalten 63230 319 216B2 11 2011 EINF HRUNG Zus tzliche Ressourcen 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Einf hrung Das EGX300 ist ein Ethernet basiertes Ger t welches eine transparente Schnittstelle zwischen Ethernet Netzen und Feldger ten bereitstellt Zu den Feldger ten geh ren Mess und berwachungsger te Schutzrelais SPS Einheiten Ausl sesysteme Motorsteuerungen und andere Ger te die mit Modbus Jbus oder PowerLogic Protokollen kommunizieren Das EGX300 benutzt das Modbus TCP IP Protokoll f r den Zugriff auf Feldger tedaten in einem LAN oder WAN Netz Diese F higkeit erm glicht den Einsatz von berwachungssoftware f r den Zugriff auf Ger tedaten f r Datenerfassung Trendverfolgung Alarm und Ereignisverwaltung Analyse und andere Funktionen Das EGX300 unterst tzt die Echtzeitdatenanzeige f r viele gebr uchliche Ger tetypen und stellt verschiedene ger tespezifische Funktionen bereit Es stehen z B Onboard Ger te und Schaltkreis bersichtsseiten sowie Onboard Datenaufzeichnung und Echtzeit Trendverfolgung zur Verf gung Abbildung 1 berblick ber das EGX300 Echtzeitansichten Betrachten von Ger tedaten mit einem einfachen Browser ohne zus tzliche Software Echtzeit Trendkurven EGX300 Webseiten Datenprotokoll Trendkurven Steuerungsr cksetzungen Auslesen von Daten von a
264. ic com Versi n del firmware 3 800 Copyright 2005 2010 Schneider Electric Todos los derechos reservados Usuario s La EGX tiene la propiedad de poder ejecutar manualmente uno o varios conjuntos de comandos de restablecimiento predefinidos por tipo de dispositivo 1 En el men Control haga clic en Abre la p gina Restablecimientos Restablecimientos 2 Seleccione un dispositivo de la lista Selecciona un dispositivo y muestra las Restablecimientos que desee ver o opciones de restablecimiento as como la fecha restablecer y hora del ltimo restablecimiento 3 Seleccione los par metros del dispositivo Selecciona la operaci n de restablecimiento que desee restablecer que se tiene que realizar en el dispositivo seleccionado 4 Haga clic en Restablecer Env a un comando o varios para los restablecimientos solicitados al dispositivo seleccionado y muestra el estado Figura 46 Restablecimientos Restablecimientos Building East Panel CM4000 Par metro Fechafhora ltimo restablecimiento Estado Fecha Hora o 2011 09 28 17 37 06 Min Max O 2011 09 28 17 35 58 Intensidad de demanda punta O 2011 09 28 17 36 00 Demanda de potencia punta O 2011 09 28 17 36 02 Energ a acumulada O 2011 09 28 17 36 03 Restablecer NOTA La fecha y hora mostradas para el par metro Fecha Hora son la fecha y hora actuales en el dispositivo seleccionado Si se ha seleccionado este par metro para res
265. ice Pages 3 Under Summary Device Pages click Opens the setup page for the Multiple Devices Multiple Devices Single Topic Single Topic page 4 Select a device from the Available Selects the devices for the summary options Devices list NOTE A maximum of four devices may be selected 5 Select a topic from the Available Topics Selects the topic to display for each selected list device NOTE Only topics that are common between the selected devices are available 6 Select Next Opens the Multiple Devices Single Topic display page 7 Hold down the left mouse button and drag Zooms in on the selected graph area a selection box around a graph area to zoom in on it 8 To return to the original full view type Z on The view zooms out your keyboard or double click on the graph The topic logged from the selected devices is displayed in a web page in a time trend chart format The time trend chart is preconfigured to display data from the Last Full Day Last Full Week Last Full Month or All Data Energy parameters are displayed as incremental values on an interval basis All other parameters are logged and displayed as the actual value recorded Figure 39 Multiple Devices Single Topic Setup Page Select Devices and Topics Available Devices Available Topics Building Main Apparent Energy kVAh Building West Panel Real Energy kWh Building East Panel Reactive Energy kVARh Building North Panel
266. icherheitsgr nden wird empfohlen das werkein gestellte Administratorkennwort nach der ersten Anmeldung zu ndern F r eine Erl uterung der Zugriffsberechtigungen f r jede Gruppe siehe die nachstehende Tabelle 12 Drei benutzerdefi Durch Auswahl aus folgenden Optionen weist der Administrator jeder nierte Gruppen Zugriffsberechtigungen Keine eine Gruppe hat keinen Zugriff auf die ausgew hlte Webseite Schreibgesch tzt das Kennwort gew hrt einer Gruppe nur Lesezugriff auf die ausgew hlte Webseite Vollst ndig eine Gruppe hat den gleichen Zugriff wie die Administrator Gruppe auf die ausgew hlte Webseite Abbildung 24 Seite Webseitenzugriff Gruppe bestimmte Webseiten Zugriffsrechte zu Es gibt folgende Erlaubt der werkeingestellten Gruppe Guest den Zugriff auf die Webseite Auswahl der Zugriffsberechtigung f r jede Webseite Echtzeitdaten Ger teprotokolldaten Resets Statistik Ger teregister lesen Kommunikationspr fung Wartungsprotokoll Ethernet amp TCP IP Serielle Schnittstelle Verbindungen zu entfernten Ger ten Ger teliste Ger teaufzeichnung Ger teprotokollexport Unterlagenlinks Pr ferenzen device html Carbon Footprint Carbon Footprint Webseitenzugriff Schreibgesch tzt Schreibgesch tzt Schreibgesch tzt x EJE Schreibgesch tzt v Schreibgesch tzt M Schreibgesch tzt me Schreibgeschitzt Schreibgesch
267. ick Audit Trail The Audit Trail page opens Follow instructions in the table below Table 14 Audit Trail Setup Maintenance Log ontrols the report types for which you want messages to display in the Message Log erver UDP user datagram protocol port o Adaresses Description As messages are generated they will display in the EGX on board maintenance log As messages are generated the will be forwarded to the server that you indicate yslog messages will be sent from this server UDP port e four report types for whic messages can be forwarded location in the system that generated the message Will display in the Syslog must determine for your facility the importance of each type When messages are generated the originator e mail address will display in the from field The body of the e mail will include EGX IP address report group name user name user IP address and the message from the report group When messages are generated they will be sent to the recipient e mail address es eck the report options that you want to include Default no options checked e ada remote server to which you want messages to be forwarded nter the UDP port number for this IP address Default 514 eck the report types for which you want messages to be forwarded address address of the originator for e mails Maximum 49 characters address address of the recipient of all message
268. ie Adresse des Ausgangs E Mail Servers 0 0 0 0 bis 255 255 255 255 ein HINWEIS Wenden Sie sich an Ihren Netzwerkadministrator wenn Sie die Adresse des SMTP Servers nicht kennen Geben Sie im Textfeld Server TCP Port die Sendeschnittstelle f r den Ausgangs E Mail Server ein Wenn der SMTP Server Anmeldedaten erfordert aktivieren Sie das Kontrollk stchen SMTP Server erfordert Anmeldung HINWEIS Das EGX unterst tzt die Zugangsauthentifizierungen Plain Login CRAM MD5 und Digest MD5 Wenn Sie das Kontrollk stchen SMTP Server erfordert Anmeldung aktiviert haben geben Sie den Benutzernamen und das Kennwort in die Textfelder ein Klicken Sie auf Test E Mail um eine Test E Mail mit den von Ihnen eingestellten Parametern zu versenden oder klicken Sie auf bernehmen HINWEIS Durch das Anklicken von Test E Mail werden die E Mail Einstellungen f r den Export des Protokolls bernommen und eine Test E Mail gesendet Wird bernehmen angeklickt werden nur die Einstellungen bernommen 63230 319 216B2 11 2011 Festlegung wann Datenprotokolle bertragen werden sollen Eingabe des Absenders der E Mail Eingabe der E Mail Adressen der Empf nger Eintrag der Adresse des Servers der Datenprotokolle ber E Mail versendet Eintrag der Sendeschnittstelle des Ausgangs E Mail Servers Werkeinstellung 25 Erm glicht die Eingabe von Anmeldedaten f r den SMTP Server
269. ie Aktivieren Sie die Berichtstypen Meldungen weitergeleitet werden k nnen f r die Meldungen weitergeleitet ausgew hlt werden sollen Dropdown Liste Liefert einen groben Anhaltspunkt zum W hlen Sie die entsprechende Anlage Standort der Anlage die die Meldung Kategorie aus generiert hat Diese Information wird im Syslog angezeigt Dropdown Liste Informiert den Benutzer ber die Wichtigkeit W hlen Sie die entsprechende Schwere der Meldung Sie m ssen f r Ihre Anlage Kategorie aus die Wichtigkeit jedes Typs bestimmen Von Adresse Wenn Meldungen generiert werden wird Geben Sie unter Von Adresse die E Mail Adresse des Absenders im die E Mail Adresse des Feld Von angezeigt Absenders f r E Mails ein Es Der Hauptteil der E Mail enth lt folgende d rfen maximal 49 Zeichen Informationen IP Adresse des EGX verwendet werden Berichtsgruppenname Benutzername IP Adresse des Benutzers und die Meldung von der Berichtsgruppe Zu Adresse Wenn Meldungen generiert werden Geben Sie unter Zu Adresse werden sie an die E Mail Adresse n des die E Mail Adresse des Empf ngers bertragen Empf ngers aller Meldungs E Mails ein Pro Adresse d rfen maximal 49 Zeichen verwendet werden Server IP Adresse Das ist die IP Adresse des Servers an Wenn keine Server IP Adresse den die E Mails bertragen werden eingegeben wird werden keine E Mails gesendet Server TCP Port Das ist die TCP Port Nummer f
270. iens de la page Configuration cliquez sur Configuration dans la barre de menus de la passerelle EGX 1 Dans le menu Configuration cliquez Ouvre la page Ethernet et TCP IP sur Ethernet et TCP IP 2 S lectionnez le format de trame etle S lectionne le format de trame et le type de support type de support Contactez votre administrateur r seau si vous ne connaissez pas ces informations 3 Entrez l adresse IP le masque de Configure les param tres Ethernet de la passerelle sous r seau et l adresse de EGX passerelle attribu s la passerelle REMARQUE Si vous saisissez une adresse IP EGX par votre administrateur r seau d j utilis e par un autre appareil le syst me vous demande d en saisir une autre Voir D tection des adresses IP identiques page 8 4 Cliquez sur Appliquer Met jour les param tres Ethernet et TCP IP de la passerelle EGX Voir le Tableau 2 ci dessous pour la liste des options Figure 3 Page Ethernet et TCP IP Ethernet et TCP IP Ethernet Adresse MAC 00 80 67 80 5A E5 Format de trame Ethernet Il Xi Type de support 10T 100Tx Auto x Param tres IP C Obtenir une adresse IP automatiquement Adresse IP 169 254 10 110 Masque de sous reseau 255 255 255 0 Passerelle par d faut 169 254 ol 10 Tableau 2 Param tres Ethernet et TCP IP de la passerelle EGX Format de trame S lection du format des donn es Ethernet Il 802 3
271. igure les param tres d enregistrement des journaux d appareil Exporter le journal de Configure les options d exportation des journaux l appareil d enregistrement Date et heure Permet de d finir la date et l heure manuellement ou par le biais de param tres SNTP Param tres SNMP Configure le protocole SNMP Simple Network Management Protocol 10 2 17 19 23 25 Filtrage Modbus TCP IP Configure les adresses IP qui peuvent acc der la passerelle EGX via le protocole Modbus TCP IP 2 2 Configure les pr f rences de la passerelle EGX Types d appareil affichables Configure les types d appareil compatibles qui peuvent tre affich s dans la page Liste des appareils EGX Piste d audit Configure la communication des messages syst me par PEGX via le journal de maintenance par courrier lectronique ou via le serveur Syslog distant Liens vers la documentation Configure les fichiers et liens de documentation Acc s aux pages Web Configure les droits d acc s aux pages Web pour chaque groupe d utilisateurs Comptes utilisateur Permet de cr er ou modifier les noms de groupe 25 6 8 29 32 33 33 a Point d acc s systeme Active et configure l adresse IP de groupe pour plusieurs passerelles EGX300 ce qui leur permet de se d tecter entre elles et d acc der mutuellement aux informations Surveillance wo Donn es en temps r el Les Pages d appareil unique affichent les mesures de base proven
272. ikationspr fung Automatische Kommunikationspr fung W hrend der Anzeige der Echtzeitdatenansichten f hrt das EGX standard m ig alle 15 Minuten eine automatische Kommunikationspr fung aus Um die Zeitsteuerung zu ver ndern siehe Pr ferenzen auf Seite 32 Damit wird die St rungsfreiheit der Kommunikation mit allen Ger ten berpr ft die im EGX konfiguriert sind und innerhalb der Browsersitzung der Wiederaufbau der Kommunikation zu jedem Ger t versucht das mit Au er Betrieb gekennzeichnet ist Manuelle Kommunikationspr fung In bestimmten F llen m chten Sie m glicherweise nicht auf die automatische Kommunikationspr fung warten und m ssen die Ausf hrung der Pr fung manuell erzwingen Klicken Sie im Diagnose Men auf Einblendung der Seite Kommunikationspr fung Kommunikationspr fung 2 Klicken Sie auf Ger testatus berpr fen Damit wird eine Kommunikationspr fung ausgef hrt Ger te mit denen eine Kommunikation m glich ist zeigen Bestanden in der Spalte Kommunikation und In Betrieb in der Spalte Status an Ger te mit denen keine Kommunikation m glich ist zeigen Fehlgeschlagen in der Spalte Kommunikation und Au er Betrieb in der Spalte Status an wenn die Verbindungsaufnahme mehrmals fehlgeschlagen ist Abbildung 49 Seite Kommunikationspr fung Kommunikationspr fung Ger t Ger tetyp Verbindung Kommunikation Status Building Main CM4000
273. ile enth lt die Spalten berschriften f r Gr en ID 3 die Gr en IDs in Zeile 5 Eine Gr en ID ist die numerische Bezeichnung der aufzuzeichnenden Gr e Der einer Gr e zugewiesene Name kann sich zwischen Ger ten und Sprachen geringf gig unterscheiden Gr en IDs werden f r die Identifizierung der Gr e unabh ngig von Ger t oder Sprache benutzt Die ersten drei Kommas dienen Layoutzwecken in einer Tabellenkalkulations anwendung 21617 1621 1625 Diese Zeile enth lt die Gr en IDs der aufgezeichneten Werte Wirkenergie kWh Blindenergie kVArh 8 und Diese Zeilen enthalten die aufgezeichneten Daten dar ber 6 300 2008 10 09 14 15 00 1400738 219 1201962 707 647069 906 15 7 Fehler UTC Abweichung Minuten Diese Zeile enth lt die Spalten berschriften der lokale Uhrzeit Scheinenergie kVAh aufgezeichneten Daten in Zeile 8 und dar ber 0 300 2008 10 09 14 20 00 1400758 260 1201980 725 647078 602 15 0 300 2008 10 09 14 25 00 1400778 198 1201998 661 647087 233 15 Wenn Sie eine Tabellenkalkulationsanwendung f r die Betrachtung der CSV Datei benutzen sollten die Daten wie in Abbildung 38 auf Seite 43 dargestellt werden 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 berwachung Abbildung 38 Intervalldatenprotokoll ge ffnet in einer Tabellenkalkulationsanwendung A B D E F G H 1
274. ilite las casillas de seleccionados verificaci n de los temas que desea visualizar y a continuaci n haga clic en Aplicar Los datos registrados de cada dispositivo aparecen en una p gina web en un formato de gr fico de tendencia del tiempo El gr fico de tendencia del tiempo est preconfigurado para mostrar los datos del ltimo d a completo la ltima semana completa el ltimo mes completo o todos los datos Los par metros de la energ a se registran como valores acumulativos pero se visualizan como valores incrementales por intervalo Los otros par metros se registran y visualizan como el valor real registrado Figura 36 Gr fico Registro de datos del intervalo Registro de datos del intervalo Building North Panel PM800 lima semana completa _ Tema s nuevo s _ __ Puntos de datos M Energia aparente KVAh 16 14 12 2010 02 13 00 00 00 2010 02 15 00 00 00 2010 02 17 00 00 00 2010 02 19 00 00 00 Seleccione un rea para verla aumentada Pulse Z o haga doble clic para deshacer la visi n aumentada Figura 37 Tabla de puntos de datos del registro de datos del intervalo Eras Indicador de Energ a Energia Energia entreg Energia recib hora entregada kWh recibida kh KVARh KVARh 0 2009 01 08 19 05 00 348 0 150 0 O 2009 01 08 18 40 00 348 0 150 0 0 2009 01 08 18 45 00 348 0 150 0 O 2009 01 08 18 50 00 348 o 150 0 0 2009 01 08 18 55 00 348 0 150 0 0 2009 01 08 19 00 00 348
275. iltered list to access serial slave devices with read only access Setting it to None blocks all Modbus TCP IP clients not in the filtered list 1 From the Setup menu click Modbus Opens the Modbus TCP IP Filtering page TCP IP Filtering 2 Check Enable Filtering Activates filtering 3 Inthe IP address column enter the Enters an IP address for a Modbus TCP IP Modbus TCP IP client address client that will have access to the devices connected to the EGX 4 Inthe Access Level column select Read Selects the access level for the corresponding only or Full IP address When set to Read only the following Modbus TCP IP function codes are allowed Decimal 1 2 3 4 7 8 11 12 17 20 24 43 100 Hexadecimal 01 02 03 04 07 08 OB OC 11 14 18 2B 64 25 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 5 Repeat steps 3 and 4 to add more IP Continues adding IP addresses for filtering addresses 6 Click Apply Saves the Modbus TCP IP address filtering list Figure 21 Modbus TCP IP Filtering Page Modbus TCP IP Filtering Enable Filtering IP Address Access Level Documentation Links The EGX supports two types of documentation links 1 Local file access documentation stored onboard the EGX 2 External URL access NOTE Local file documents you want to appear on the Documentation web page must be placed in the EGX www documentation folder
276. in CRAM MD5 y Digest MD5 Si ha marcado la casilla de verificaci n El servidor SMTP requiere iniciar sesi n introduzca su nombre de usuario y su contrase a en los cuadros de texto correspondientes Haga clic en Correo electr nico de prueba para enviar un correo electr nico de prueba utilizando los par metros establecidos por usted o haga clic en Aplicar NOTA Al hacer clic en Correo electr nico de prueba se aplican los valores de correo electr nico para exportar registros y se env a un correo electr nico de prueba y al hacer clic en Aplicar s lo se aplican los valores Selecciona cu ndo se env an los registros de datos Introduce desde qu direcci n se ha enviado el correo electr nico Introduce las direcciones de correo electr nico de los receptores Introduce la direcci n del servidor que entrega los registros de datos de correo electr nico Introduce el puerto de entrega del servidor de correo saliente Predeterminado 25 Le permite introducir informaci n de inicio de sesi n del servidor SMTP Registra su informaci n de inicio de sesi n del servidor SMTP Env a un correo electr nico de prueba aplica los valores de correo electr nico para exportar registros o realiza ambas acciones Figura 15 P gina Exportaci n de registros de dispositivos Correo electr nico Exportaci n del registro de dispositivos Transporte O Desactivado Correo el
277. in the Status column if it has failed multiple times Figure 49 Communications Check Page Communications Check Device vice T Connection Comms Status Building Main CM4000 10 168 253 60 Passed In Service Building West Panel CM2000 10 168 253 60 Passed In Service Building East Panel CM3000 10 168 253 60 Passed In Service Building North Panel PM800 10 168 253 60 Passed In Service 55 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Maintenance 11 2011 MAINTENANCE The Maintenance Log provides you with a way to document maintenance performed on the EGX the connected equipment or the system of which the EGX is a part Each entry is recorded with the date and time the entry was made and the name of the user who made it This log will also automatically list system activity such as enabling or disabling features You do not need to add entries for these items Finally this log will list all activities that are specified for the Maintenance Log in the Audit Trail setup page see Audit Trail on page 33 1 From the Maintenance menu click Opens the Maintenance Log page Maintenance Log 2 Select the Delete checkbox next to the Deletes the selected entry entry you want to delete then click Delete Entries 3 Click Delete Log to delete all entries in the Clears the maintenance log maintenance log 4 To add a new log entry click Add Log Opens the Add Log Entry page and allows the Entr
278. inactivit d fini Par d faut 120 secondes D lai d inactivit de D compte permettant de fermer une connexion 0 65 000 s la connexion HTTP HTTP apr s le temps d inactivit d fini Par d faut 4 secondes Num ro de port Port TCP utilis pour les messages HTTP Les 0 65 000 HTTP num ros de port suivants sont r serv s d autres Par d faut 80 protocoles r seau et ne sont donc pas disponibles 0 d sactive le port 20 et 21 FTP et 502 Modbus TCP IP HTTP Num ro de port Port TCP utilis pour les messages HTTPS 1 65 000 HTTPS La passerelle EGX est fournie avec un certificat auto Par d faut 443 sign Pour authentifier EGX comme serveur vous 0 d sactive le port devez obtenir un certificat d une autorit de HTTPS certification par exemple VeriSign Authentication Services Pour ajouter ou installer un certificat num rique ouvrez la page de mise jour du certificat l adresse http x x x x update_certs_shtml o x x x x correspond l adresse IP de l EGX Tentatives de Permet de sp cifier le nombre maximal de tentatives 0 65 000 maintien de la de maintien de la connexion HTTP Par d faut 100 connexion HTTP Connexions serveur Permet de sp cifier le nombre de connexions 16 64 Modbus TCP IP serveur Modbus TCP IP disponibles Par d faut 32 Diffusion Modbus D termine le traitement par le sous r seau s rie des D sactiv Activ messages Modbus TCP IP d
279. ind Ger te die vorher in die Ger teliste eingetragen wurden werden unabh ngig vom eingestellten Erkennungsbereich berpr ft Erkennung Zu Beginn der Ger teerkennung fragt das EGX den lokalen seriellen Port mit einem benutzerdefinierten Adressenbereich ab siehe Abbildung 12 auf Seite 16 F r die Erkennung an der seriellen Schnittstelle wird je nach deren aktueller Konfiguration das Modbus ASCII oder das RTU Protokoll benutzt Wenn das Ger t auf die Anfrage antwortet wird die lokale ID auf die aktuelle Erkennungsadresse gesetzt und dem Ger t wird ein voreingestellter Ger tename zugewiesen Das EGX versucht dann den Ger tetyp zu erkennen Wenn das EGX den Typ des erkannten Ger ts identifiziert wird die Bezeichnung des erkannten Ger tetyps in das Feld Ger tetyp eingetragen Kann das EGX den Ger tetyp nicht identifizieren wird das Feld Ger tetyp auf die Werkeinstellung Modbus gesetzt Ein Statusfeld zeigt den Erkennungsstatus an berpr fung W hrend des Erkennungsvorgangs werden alle vorher definierten Eintr ge in der Ger teliste f r alle Verbindungen serielle und Fernverbindungen innerhalb und au erhalb des Erkennungsbereichs zwischen Start und Endadresse berpr ft Das berpr fungsprotokoll der seriellen Verbindung wird durch die aktuelle Konfiguration des Ger ts in der Ger teliste bestimmt F r die berpr fung entfernter Ger te wird das Modbus TCP IP Protokoll benutzt Das EGX zeigt die
280. is 65535 des UDP Ports ein der f r die Erkennung ber den Systemzugangspunkt verwendet wird Werkeinstellung 59 4 Gruppen IP Adresse Geben Sie die Gruppen IP Adresse ein die Multicast oder Unicast Adressen unterst tzt Werkeinstellung 224 0 1 2 5 Meldungsintervall Das ist die Zeit zwischen den Hallo Meldungen die vom EGX300 ausgegeben werden um anderen Systemzugangsger ten von Schneider Electric seine Anwesenheit im Netzwerk mitzuteilen 1 65535 Sekunden Werkeinstellung 300 Sekunden 2011 Schneider Electric Alle Rechte vorbehalten 35 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 6 Haltezeit Das ist die Zeit f r die vom jeweiligen EGX300 gesendete Hallo Meldungen von Empf ngern gehalten werden m ssen bevor dieses EGX300 als nicht verf gbar angesehen wird Von 2 bis 65535 Sekunden Werkeinstellung 600 Sekunden 7 Multicast G ltigkeitsdauer Sie k nnen die Gr e des Netzwerkbereichs festlegen der zur Erkennung von anderen Ger te verwendet wird Das wird durch die zul ssige Anzahl der Multicast Weiterleitungen an andere Ger te geregelt Der Bereich der zul ssigen Router Spr nge betr gt 1 255 Werkeinstellung 1 8 Gemeinschaft EGX300 Ger te in einer Gruppe k nnen in Gemeinschaften unterteilt werden EGX300 Ger te mit derselben Gruppen IP Adresse und Gemeinschaftsnummer k nnen sich untereinander erkennen Durch Einstellung der Gemeinschaftsnummer
281. ision Paginas de dispositivo unico Las paginas de dispositivo Unico proporcionan representaciones en forma de gr ficos y tablas de los datos registrados de un nico dispositivo 1 En el men Supervisi n haga clic en Ampl a el rbol para mostrar las opciones Registro de dispositivos disponibles de registro de dispositivos 2 En Registro de dispositivos haga clic en Ampl a el rbol para mostrar los dispositivos P ginas de dispositivo nico disponibles cuyos datos registrados se pueden visualizar 3 Seleccione un dispositivo de la lista Muestra el registro de dispositivo Registro de dispositivos correspondiente al dispositivo seleccionado 4 Para ver un rango de datos selecci nelo Elabora un gr fico correspondiente al rango de en la lista desplegable de rangos de datos datos seleccionado 5 Mantenga pulsado el bot n izquierdo del Aumenta la zona del gr fico seleccionada rat n y arrastre un cuadro de selecci n alrededor de una zona del gr fico para ampliarla 6 Para volver a la vista completa original Se reduce el zoom de la vista escriba Z en el teclado o haga doble clic sobre el gr fico 7 Haga clic en Puntos de datos para Abre la tabla del registro de datos del visualizar la tabla del registro de datos del intervalo seleccionado intervalo seleccionado consulte m s adelante la Figura 37 8 Para visualizar otros temas haga clic en Habilita la visualizaci n de los temas Tema s nuevo s Hab
282. it chaque envoi d une trame Trames re ues Compteur qui augmente d une unit a chaque r ception d une trame Connexions actives Valeur qui indique le nombre de connexions actives lors de la mise jour de la page de diagnostics Prise en charge de 20 connexions maximum Cliquez sur Connexions actives pour ouvrir une nouvelle fen tre qui affiche la liste de toutes les connexions client actives Connexions cumul es Compteur qui augmente d une unit chaque connexion tablie avec la passerelle EGX Nombre maximal de connexions Valeur qui indique le nombre maximal de connexions qui taient actives un instant donn TCliquez sur le lien pour plus d informations O 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Diagnostics Informations sur la passerelle Version du logiciel embarqu Version du logiciel embarque install amp sur la passerelle ECK D lai d inactivit du syst me P riode moyenne d inactivit du processeur exprim e en pourcentage 0 100 Num ro de s rie Num ro de s rie de la passerelle EGX Client HTTP Envoi OK Compteur qui augmente d une unit chaque fois qu un fichier est envoy sans probl me au serveur HTTP Erreur de connexion Compteur qui augmente d une unit chaque fois que la passerelle EGX ne parvient pas tablir la connexion avec le serveur HTTP Erreur d authentification Compte
283. ite un m ximo de 20 conexiones Haga clic en Conexiones activas para abrir una ventana nueva con una lista de todas las conexiones clientes activas Conexiones acumulativas Contador que aumenta cada vez que se realiza una conexi n a la EGX M ximo de conexiones Valor de estado que representa el n mero m ximo de conexiones que pueden estar activas en un momento dado THaga clic en el vinculo para obtener informaci n adicional en detalle 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Diagn sticos Informaci n de pasarela Versi n del firmware Versi n del firmware que esta instalada en la EGX Tiempo de inactividad del sistema Porcentaje del 0 al 100 que indica el tiempo medio de procesador que no se utiliza Direcci n MAC Direcci n exclusiva del hardware Ethernet de una EGX Cliente HTTP Envio correcto Contador que aumenta cada vez que se envia un archivo correctamente al servidor HTTP Error de conexi n Contador que aumenta cada vez que la EGX no puede conectarse al servidor HTTP Error de autenticaci n Contador que aumenta cada vez que el servidor HTTP no puede autenticar las credenciales del usuario o contrasena Error de envio Contador que aumenta cada vez que no se puede transferir un archivo al servidor HTTP Error general Contador que aumenta cada vez que no se puede transferir un archivo debido a la incapacidad de la EG
284. iviert automatisch von einem BootP Server Werkeinstellung Deaktiviert erhalten HINWEIS Erfordert die Unterst tzung der Netzwerkadministration IP Adresse Eingabe der statischen IP Adresse des EGX Werkeinstellung 169 254 0 10 Subnetzmaske Eingabe der Ethernet IP Subnetzmasken Werkeinstellung 255 255 0 0 adresse Ihres Netzwerks Standard Eingabe der Gateway IP Adresse Router f r Werkeinstellung 0 0 0 0 Gateway WAN Kommunikation PowerLogic Ethernet Gateway EGX300 Setup Erweiterte Ethernet Einstellungen 63230 319 216B2 11 2011 ACHTUNG BEEINTR CHTIGTE LEISTUNGSF HIGKEIT DES NETZWERKS Die erweiterten Ethernet Einstellungen des EGX d rfen nur von qualifiziertem Personal vorgenommen werden Diese nderungen d rfen grunds tzlich erst vorgenommen werden wenn die Informationen ber die erweiterten Einstellungen vollst ndig gelesen und verstanden wurden Durch Nichtbeachtung dieser Anweisungen kann die Leistungsf higkeit des Netzwerks beeintr chtigen sane ge 1 Klicken Sie auf der Seite Ethernet amp Einblendung der Seite Erweiterte Ethernet TCP IP auf Erweitert Einstellungen 2 Konfigurieren Sie die erweiterten Ethernet Einrichtung der erweiterten Ethernet Einstellungen Tabelle 3 auf Seite 7 enth lt Einstellungen die verf gbaren Optionen Klicken Sie auf Standardwerte um die Standardwerte f r alle Optionen auszuw hlen 3 Klicken Sie auf bernehmen Aktualisi
285. ivos remotos La EGX muestra el ID local el nombre del dispositivo almacenado y el tipo de dispositivo almacenado de Lista de dispositivos y luego consulta al dispositivo Se muestra el tipo de dispositivo identificado por la consulta y luego se compara con lo que se ha definido previamente El estado mostrar entonces si se ha encontrado una diferencia o si es v lida la configuraci n previamente definida NOTA Puede editar el nombre del dispositivo y el tipo de dispositivo y seleccionar individualmente los dispositivos que se guardar n en Lista de dispositivos Sin embargo si est habilitado el registro para un dispositivo s lo podr modificar su nombre 1 En el men Configuraci n haga clic en Lista Abre la p gina Lista de dispositivos de dispositivos 2 Para detectar dispositivos conectados Abre la p gina Detecci n de dispositivos localmente haga clic en Detecci n 3 Introduzca una direcci n de comienzo y una Introduce el intervalo de direcciones de direcci n de fin detecci n NOTA Se validar n los dispositivos introducidos previamente en la lista de dispositivos con direcciones ID locales fuera del intervalo de detecci n 4 Haga clic en Iniciar detecci n Haga clic en Comienza por detectar todos los Detener detecci n para detener el proceso dispositivos conectados y definidos NOTA La detecci n s lo busca dispositivos serie Modbus locales conectados a la EGX Los dispositivos remotos s
286. ivos 21 para a adir p ginas web 30 para eliminar p ginas web 30 para recuperar registros cronol gicos de datos 43 H hardware 59 historial de auditor a 33 cuadro Syslog 34 registro de mantenimiento 34 HTTP exportaci n registro de dispositivos 22 n mero de puerto configuraci n 7 recuperaci n de registros de datos de intervalo 44 HTTPS n mero de puerto configuraci n 7 inicio de sesi n en la EGX 2 interfaz de usuario EGX 3 intervalos de registro 17 introducci n 1 L lectura de registros de dispositivo 54 lista de dispositivos EGX 12 N niveles de acceso a la EGX 25 O otros recursos 1 P p gina de documentaci n 49 p ginas de dispositivo nico 37 41 de resumen de dispositivos 38 45 web adici n a eliminaci n de la interfaz web 31 configuraci n 29 personalizadas configuraci n 30 2011 Schneider Electric Reservados todos los derechos Pasarela Ethernet EGX300 de PowerLogic ndice alfab tico paneles de instrumentos 46 par metros del SNMP configuraci n 25 preferencias personalizaci n de la EGX 32 protocolos Ethernet compatibles 59 punto de acceso del sistema configuraci n 35 enlaces a otras EGX300 48 R rango de los indicadores anal gicos 38 red acceso a trav s de una 2 registro 17 40 cronol gico de datos c digos de error 43 recuperaci n 42 recuperaci n mediante FTP 43 de datos de intervalo mediante bot n Puntos de datos 44 mediante correo electr
287. keit der Werkeinstellung Gerade Daten mit einem Parit ts Bit erforderlich ist Antwort Dieser Parameter legt fest wie lange das 10 1 bis 10 Sekunden Zeit berschreitung EGX auf den Empfang einer Antwort von Werkeinstellung 3 Sekunden einem seriellen Ger t wartet Nur verf gbar wenn die physische Schnittstelle bzw der bertragungsmodus auf RS232 Modbus ASCII eingestellt ist ACHTUNG BEEINTR CHTIGTE LEISTUNGSF HIGKEIT DES NETZWERKS Die erweiterten Einstellungen der seriellen Schnittstelle des EGX d rfen nur von qualifiziertem Personal vorgenommen werden Diese nderungen d rfen grunds tzlich erst vorgenommen werden wenn die Informationen ber die erweiterten Einstellungen der seriellen Schnittstelle vollst ndig gelesen und verstanden wurden Durch Nichtbeachtung dieser Anweisungen kann die Leistungsf higkeit der seriellen Kommunikation beeintr chtigen Ma nahme Ergebnis 1 Klicken Sie auf der Seite Serielle Schnittstelle auf Erweitert Einblendung der Seite Erweiterte Einstellungen der seriellen Schnittstelle 2 Konfigurieren Sie die erweiterten Einstellungen der Einrichtung der erweiterten seriellen Schnittstelle Tabelle 6 auf Seite 11 enth lt die Einstellungen der seriellen verf gbaren Optionen Klicken Sie auf Standardwerte Schnittstelle um die Standardwerte f r alle Optionen auszuw hlen 3 Klicken Sie auf bernehmen Aktualisierung der erweiterten sr T x Einstellunge
288. l Energie apparente kVAh Energie et suivantes active kWh Energie r active kVArh ligne 8 0 300 2008 10 09 14 15 00 1400738 219 1201962 707 647069 906 15 0 300 2008 10 09 14 20 00 1400758 260 1201980 725 647078 602 15 0 300 2008 10 09 14 25 00 1400778 198 1201998 661 647087 233 15 Si vous affichez le fichier CSV dans un tableur la pr sentation des donn es devrait ressembler celle de la Figure 38 page 43 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Surveillance Figure 38 Journal de donn es d intervalle ouvert dans un tableur ia A c D E F G H l 1 Gateway Name Gateway SN Gateway IP Address Gateway MAC Address Device Name Device Local ID Device Type ID Device Type Name Log Interval 2 EGX300 0 157 198 184 125 00 80 67 80 5B 61 Building Main 1 5 CM4000 5 3 4 Topic ID 1 Topic ID 2 Topic ID 3 5 1617 1621 1625 6 FAI Error UTC Offset Minutes Local Time Stamp Energie apparente kVAh Energie active kWh Energie r active kVARh 8 0 360 02 12 2010 13 20 2 708 484 084 2 436 019 161 1 160 734 726 EN 0 360 02 1 2 2010 13 25 2 708 509 192 2 436 042 802 1 160 743 040 10 0 360 02 12 2010 13 30 2 708 534 061 2 436 066 114 1 160 751 553 0 360 02 12 2010 13 35 2 708 559 927 2 436 090 052 1 160 761 238 12 0 360 02 12 2010 13 40 2 708 586 181 2 436 114 595 1 160 770 444 13 0 360 02 12 2010 13 4
289. l grupo y el idioma para un usuario predeterminado para el nuevo usuario 5 Repita los pasos 3 y 4 por cada Contin a a adiendo usuarios usuario adicional que desee agregar 6 Haga clic en Aplicar Guarda toda la configuraci n de las cuentas de usuario Tabla 11 Cuentas y contrase as de la EGX NOTA Los nombres de usuario y las contrase as respetan may sculas y min sculas y s lo pueden contener caracteres alfanum ricos Cuentas definidas por el usuario hasta 11 cuentas Sin valor predeterminado La contrase a la define el usuario Figura 23 P gina Cuentas de usuario Cuentas de usuario Grupos Engineering Operations Maintenance Usuarios Nombre Contrase a Grupo Idioma se Espa ol v Engineering M Espa ol x Administrators v Espa ol x Operations y Espa ol Administrators iv Espa ol M Administrators Ml Ingl s M Administrators Y Franc s saminisrators y Aeman y Maintenance EA Espa ol j Maintenance v Espa ol v Maintenance x Espa ol y Maintenance Y Espa ol 4 Espa ol las O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Configuracion Acceso a pagina Web 1 Enel men Configuraci n haga clic en Acceso a Abre la pagina Acceso a pagina Web p gina Web 2 Seleccione el nivel de acceso Ninguna S lo Consulte la Tabla 12 a continu
290. l moment les s lectionnez l heure le jour de la semaine et ou le jour du journaux de donn es sont mois envoy s 2011 Schneider Electric Tous droits r serv s 19 Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Configuration 11 2011 6 Dans la zone de texte De l adresse tapez l adresse D finit l exp diteur du courrier lectronique de la personne responsable de l appareil lectronique REMARQUE L adresse lectronique de l expediteur est indispensable car la plupart des serveurs SMTP la demandent Dans les zones de texte Aux adresses tapez les D finit les adresses adresses lectroniques 5 maximum des destinataires _ lectroniques des destinataires des journaux de donn es une adresse par zone Dans les zones de texte Adresse IP du serveur D finit l adresse du serveur qui saisissez l adresse du serveur de courrier sortant de envoie les journaux 0 0 0 0 255 255 255 255 REMARQUE Contactez votre administrateur r seau si vous ne connaissez pas l adresse du serveur SMTP Simple Mail Transfer Protocol Dans la zone de texte Port TCP du serveur saisissez le D finit le port d exp dition du port d exp dition du serveur de courrier sortant serveur de courrier sortant Par d faut 25 Si le serveur SMTP exige une authentification activez Permet de saisir les identifiants l option Connexion au serveur SMTP via de connexion au serveur SMTP authentification REMARQUE La pass
291. l to send a test e mail Sends a test e mail and or applies the log using the parameters you set or click export e mail settings Apply NOTE Clicking Test E mail applies the log export e mail settings and sends a test e mail and clicking Apply only applies the settings Figure 15 Device Log Export Page E mail Device Log Export Transport Disabled 9 E mail O FTP O HTTP Incremental Schedule Logging Interval Hourly Daily Weekly Monthly Time of Day 00 00 a Day of the Week Day ofthe Month 1 E E Mail Parameters From Address To Addresses Server IP Address 0 0 0 0 Server TCP Port 25 SMTP server requires login Username Password Manual Export Test E Mail Apply 2011 Schneider Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Setup FTP Export 1 From the Setup page click Device Log Opens the Device Log Export page Export 2 Select FTP as the mode of transport Opens the FTP device log export options 3 Enable the Incremental check box Selects only new data logged since the last NOTE If the transport is scheduled for good send interval to be sent Hourly or Logging interval the incremental check box will be automatically selected NOTE If the Incremental check box is not selected the whole log file is s
292. l um eins erh ht wenn eine Schreibnachricht empfangen wird ils Ausf hrliche Tabelle mit Fern und seriellen Statistiken pro Ger t HTTP Server Rahmen gesendet Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen gesendet wird Rahmen empfangen Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen empfangen wird Aktive Verbindungen Statuswert der die Anzahl der Verbindungen darstellt die zum Zeitpunkt der Aktualisierung der Diagnoseseite aktiv sind Es werden maximal 20 Verbindungen unterst tzt Klicken Sie auf Aktive Verbindungen um ein neues Fenster mit einer Liste aller aktiven Client Verbindungen zu ffnen Summe der Verbindungen Z hler der sich jedes Mal um eins erh ht wenn eine Verbindung zum EGX aufgebaut wird Maximale Anzahl Verbindungen Statuswert der die maximale Anzahl von Verbindungen darstellt die aufgebaut werden TKlicken Sie f r weitere ausf hrliche Informationen auf den Link 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Diagnose Gateway Informationen Firmwareversion System Leerlaufzeit MAC Adresse Seriennummer Modellnummer Hardwareversion Herstellungsdatum Das ist die Firmwareversion die im EGX installiert ist Prozentsatz von 0 bis 100 der die durchschnittliche ungenutzte Prozessorzeit anzeigt HTTP Client Senden OK
293. la configuraci n seleccionada Tabla 19 Par metros de lectura de registros de dispositivo de la EGX open Jen Y a Nombre del dispositivo Selecciona un dispositivo que leer de la lista de dispositivos a adidos previamente Para leer un dispositivo no definido en la lista de dispositivos introduzca el ID local de este ID local La direcci n del dispositivo que se tiene que leer Registro de inicio El primer registro para leer 1000 N mero de registros El n mero de registros para leer 1 a 125 Muestra una lista con los n meros de los registros Muestra una lista de los datos almacenados en un registro Los valores recuperados dependen del dispositivo conectado a la EGX Consulte la documentaci n correspondiente al dispositivo Columna Registro Columna Valor conectado para obtener m s informaci n acerca de los valores de los registros almacenados Tipo de datos Seleccione Registros de retenci n Registros de entrada Bobinas de salida Bobinas de entrada o de dispositivo Opciones Decimal eccione una opci n para especificar el modo Decimal Hexadecimal Binario visualizaci n de los datos de la columna o ASCII or Registros de retenci n O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Comprobaci n de las comunicaciones Comprobaci n de comunicaciones automatizada Comprobaci n de comunicaciones manual Pasarela Ethernet EGX300 de PowerLogic Diagn stico
294. la EGX300 a Direcci n IP de la EGX100 la EGX300 169 254 0 28 e Direcci n IP de aa Ed 169 254 0 75 Conexi n Son posibles hasta RS485 16 conexiones IP remotas 1 fees nd y Dispositivos esclavos remotos Dispositivos esclavos en serie 12 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Configuraci n de la lista de dispositivos 2011 Schneider Electric Reservados todos los derechos Pasarela Ethernet EGX300 de PowerLogic Configuraci n 1 En el men Configuraci n haga clic en Abre la p gina Lista de dispositivos Consulte Lista de dispositivos la Figura 10 para conexiones exclusivamente locales o bien la Figura 11 si hay conexiones remotas disponibles 2 Utilice Detecci n para localizar dispositivos Abre la pagina Detecci n de dispositivos para conectados localmente consulte detectar todos los dispositivos conectados Detecci n de dispositivos en la localmente p gina 15 Sise requiere configuraci n de dispositivos remotos contin e en el paso 3 3 Consulte la Figura 11 de la p gina 14 y Selecciona el n mero de ubicaciones seleccione el n mero de dispositivos visualizables que utilizar para definir los visualizables 1 a 64 dispositivos conectados a la EGX 4 Seleccione la conexi n en la lista Selecciona la conexi n desplegable 5 Seleccione el tipo de dispositivo en la Selecciona el tipo de
295. la lista de dispositivos se puede habilitar independientemente para registro de datos Los temas que registrar son exclusivos de cada dispositivo Para ver los registros de datos de intervalo consulte Registro de dispositivos en la pagina 40 NOTA Para habilitar la funci n Registro de dispositivos es necesario seleccionar un valor de tiempo en la ventana desplegable Intervalo de registro Se recomienda que deshabilite la funci n de registro de dispositivos correspondiente al dispositivo que se esta configurando Para ello consulte la Figura 13 de la pagina 18 y desactive la casilla de verificaci n de registro relativa al dispositivo que se va a seleccionar O 2011 Schneider Electric Reservados todos los derechos 17 Pasarela Ethernet EGX300 de PowerLogic M Configuraci n Temas que registrar 18 63230 319 216B2 11 2011 AA Resultado 1 En el men Configuraci n haga clic en Registro de Abre la p gina Registro de dispositivos consulte la Figura 13 dispositivos 2 Consulte la Figura 13 y marque Registro para los Selecciona los dispositivos que se dispositivos que desee registrar tienen que registrar Para seleccionar todos los dispositivos haga clic en seleccionar todo y a continuaci n haga clic en Aplicar Para cancelar la selecci n de todos los dispositivos haga clic en borrar y a continuaci n haga clic en plicar 3 Seleccione el intervalo de registro Selecciona el intervalo de registr
296. le y Lecture seule x Aucune iy Carbon Footprint Lecture seule Lecture seule M Lecture seule Aucune lv Carbon Footprint Lecture seule v Lecture seule v Lecture seule w Aucune x Ajouter Supprimer des pages Web Appliquer 2011 Schneider Electric Tous droits r serv s 29 Passerelle Ethernet PowerLogic EGX300 Configuration Ajout Suppression de pages Web personnalis es Ajout de pages Web personnalis es par FTP Suppression de pages Web personnalis es par FTP 30 63230 319 216B2 11 2011 Les pages Web personnalis es et autres fichiers peuvent tre transf r s de votre ordinateur vers la passerelle EGX par FTP Les fichiers plac s via FTP dans les r pertoires www monitoring surveillance www maintenance ou www control commande s ils sont dot s de l extension htm html ou shtml sont automatiquement s curis s La barre de menus de l interface Web comporte un lien vers chacun de ces dossiers Lorsque vous cliquez sur l un de ces liens les pages personnalis es que vous ajoutez apparaissent dans le menu dans la partie gauche de la fen tre du navigateur sous Pages personnalis es REMARQUE Vous ne pouvez pas cr er de nouveaux dossiers dans les dossiers pr d finis Monitoring Control et Maintenance Une fois les pages Web personnalis es ou autres fichiers transf r s vers la passerelle EGX par FTP il est possible de les ajouter ou de l
297. le EGX 2 Acc s des URL externes REMARQUE Les documents locaux que vous voulez faire appara tre sur la page Web Documentation doivent tre plac s dans le dossier EGX www documentation par FTP 1 Dans le menu Configuration cliquez sur Affiche la page Liens vers la documentation Liens vers la documentation 2 Pour l acc s aux fichiers s lectionnez la D finit quels fichiers et URL apparaissent la case cocher Activ du ou des liens vers page Documentation les noms de fichiers que vous voulez activer Pour l acc s aux URL s lectionnez la case cocher Activ du ou des liens URL que vous voulez activer 3 Activez l option Nouvelle fen tre si vous Definit quels fichiers et URL s ouvrent dans une voulez que les fichiers et URL s lectionn s nouvelle fen tre lorsqu ils sont cliqu s s ouvrent dans une nouvelle fen tre lorsque l utilisateur clique dessus 4 Definit le titre du lien vers la documentation D finit le titre du lien vers la documentation qui dans la zone de texte Texte du lien apparait sur la page Documentation 5 Cliquez sur Appliquer Met jour les param tres des liens vers la documentation EGX 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Configuration Figure 22 Page Liens vers la documentation Liens vers la documentation Le r
298. le nombre de types d appareil pris en charge par la passerelle EGX300 le fait de supprimer certaines entr es de la liste des types disponibles permet de simplifier la configuration dans la page Liste des appareils 1 Dans le menu Configuration cliquez sur Types Ouvre la page Types d appareil d appareil affichables affichables 2 S lectionnez les types d appareil qui doivent tre Permet de s lectionner les types disponibles dans la liste de configuration d appareil qui doivent tre disponibles dans la liste de REMARQUE Cliquez sur s lectionner tout pour configuration activer tous les appareils et sur effacer pour d sactiver tous les appareils REMARQUE Vous ne pouvez changer la disponibilit des types d appareil correspondant des appareils en cours d utilisation 3 Cliquez sur Appliquer Enregistre les param tres de Types d appareil affichables Figure 27 Page Types d appareil affichables Types d appareil affichables ee st Y ATS48 7 ATV61 z ATV71 Y Accusine 7 BCM a BCPM Model A Y BCPM Model B Y Model C La piste d audit est une s quence horodat e d enregistrements ou de messages Elle consigne les changements de configuration les erreurs et les checs d authentification et indique l utilisateur l origine de chaque v nement Utilisez la page Piste d audit pour configurer les groupes de rapports et canaux de messages
299. lectronique exporter le journal de l appareil 19 journal de donn es d intervalle 44 D date et heure configuration 23 d tection des adresses IP identiques 8 d tection des appareils 15 diagnostics 50 donn es en temps r el 37 E EGX connexion 2 interface utilisateur 3 liste des appareils 12 enregistrement 17 40 format de donn es 42 grandeurs 18 intervalles 17 exportation du journal de l appareil 19 configuration 19 F filtrage Modbus TCP IP configuration 25 format des journaux de donn es 42 2011 Schneider Electric Tous droits r serv s ftp exporter le journal de l appareil 21 pour ajouter des pages Web 30 pour obtenir un journal de donn es 43 pour supprimer des pages Web 30 H HTTP exporter journal de l appareil 22 num ro de port configuration 7 obtention d un journal de donn es d intervalle 44 HTTPS num ro de port configuration 7 interface utilisateur EGX 3 intervalles d enregistrement 17 introduction 1 J journal de donn es codes d erreur 43 obtenir via ftp 43 obtention 42 journal de donn es d intervalle l aide d une requ te Web Microsoft 44 par courrier lectronique 44 via ftp 43 via HTTP 44 via le bouton d acc s aux donn es 44 journal de maintenance 56 piste d audit 34 journaux d appareil 17 40 L lecture de registres d appareils 54 liens vers la documentation configuration 26 liste des appareils EGX 12 logiciel embarqu firmware mise jour
300. len Schnittstelle antwortet Modbus TCP IP verwendet Ox0B Allerdings wurde bei einigen lteren Software Suites 0x0A verwendet Verbindungen zu entfernten Ger ten Das EGX kann Verbindungen f r bis zu 16 eindeutige benutzerdefinierte entfernte Modbus TCP IP Ger te herstellen Verbindungen k nnen manuell eingegeben oder aus einer Tabelle mit vom Systemzugangspunkt erkannten Verbindungen ausgew hlt werden siehe Abbildung 7 Diese Verbindungen werden auf der Seite zum Einrichten der Ger teliste f r die Konfiguration entfernter Ger te zur Verf gung gestellt Ma nahme Ergebnis 1 Klicken Sie im Setup Men auf Anzeige der Seite Verbindungen zu entfernten Verbindungen zu entfernten Ger ten Ger ten 2 Manuelles Hinzuf gen einer Verbindung Eingabe der IP Adressen der entfernten Geben Sie die IP Adressen f r die Ger te entfernten Ger te ein mit denen Sie eine Verbindung herstellen m chten 3 Hinzuf gen einer vom Eingabe der IP Adresse der ausgew hlten Systemzugangspunkt erkannten vom Systemzugangspunkt erkannten Verbindung Klicken Sie auf Hinzuf gen Verbindung rechts neben der gew nschten Verbindung in der Tabelle der erkannten Verbindungen 4 Klicken Sie auf bernehmen Aktualisierung der EGX Einstellungen f r Verbindungen zu entfernten Ger ten 10 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 2011 Schneider Electric Alle Rechte vorbehalten
301. les de s curit du mot de passe minuscules ils peuvent contenir uniquement des Rouge Mot de passe vide Mot caract res alphanum riques de passe faible Jaune Mot de passe moyen Mot de passe fort Mot de passe tr s fort 4 S lectionnez le groupe ainsi que la langue par d faut S lectionne le nom et la langue de du nouvel utilisateur l utilisateur 5 Recommencez les op rations 3 et 4 pour chaque Ajoute d autres utilisateurs utilisateur que vous voulez ajouter 6 Cliquez sur Appliquer Enregistre tous les param tres d un compte utilisateur Tableau 11 Comptes et mots de passe EGX Comptes personnalis s jusqu 11 comptes Aucune valeur par d faut Le mot de passe personnalis est d fini par l utilisateur Figure 23 Page Comptes utilisateur Comptes utilisateur Groupes Engineering Operations Maintenance Utilisateurs Nom Mot de passe Groupe Langue ss Frangais x Engineering x Fran ais y Administrators v Frangais x Operations y Fran ais y Administrators Fran ais M Administrators M Anglais Administrators v Espagnol Administrators v Allemar a Maintenance y Anglais EA Maintenance e Anglais aa Maintenance LM Anglais hd Maintenance Mi Anglais Ed Anglais O 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11
302. lisateur user Mot de passe SSL Exportation manuelle Courier lectronique de test Test FTP Test HTTP La page Date et heure permet de r gler la date et l heure de la passerelle ECK 1 Dans le menu Configuration cliquez sur Ouvre la page Date et heure Date et heure 2 R glez l ann e le mois le jour l heure les R gle la date et l heure minutes et les secondes 3 S lectionnez le d calage horaire R gle l horloge sur le fuseau horaire s lectionn 4 Pour que l horloge passe automatiquement Permet l horloge de passer automatiquement l heure d t s lectionnez la case l heure d t cocher Activer le r glage automatique de l heure d ete 5 Saisissez l ordinal le jour de la semaine le D finit le d but et la fin de l heure d t mois et l heure de d but et de fin de l heure d t 6 Cliquez sur Appliquer Enregistre les param tres de date et d heure Figure 18 Page Date et heure Date et heure Activer synchronisation de l heure r seau 2008 x sanvier w 26 x 15 y 52 v 25 x D calage horaire UTC 06 00 x Activer le r glage automatique de l heure d t Debut de l heure d t Deuxi me Dimanche de Mars a 02 00 Fin de l heure d t Premie Dimanche de embre 4 02 00 23 Passerelle Ethernet PowerLogic EGX300 Co
303. ll erfolgreichen Datenexport aufgezeichnete HINWEIS Wenn die bertragung Daten f r das Senden ausgew hlt St ndlich oder zum Aufzeichnungsintervall geplant ist wird das Kontrollk stchen Inkrementell automatisch aktiviert HINWEIS Wenn das Kontrollk stchen Inkrementell nicht aktiviert ist wird die gesamte Protokolldatei in jedem geplanten Intervall ber HTTP bertragen W hlen Sie St ndlich T glich Festlegung wie oft Datenprotokolle bertragen W chentlich Monatlich oder werden sollen Aufzeichnungsintervall aus W hlen Sie je nach Auswahl der Optionen Festlegung wann Datenprotokolle bertragen im vorangegangenen Schritt die Tageszeit werden sollen den Wochentag und oder den Tag des Monats Geben Sie in die Textfelder Server IP Eintrag der IP Adresse des Servers der die Adresse die Adresse des HTTP Servers Datenprotokolle bertr gt ein HINWEIS Wenden Sie sich an Ihren Netzwerkadministrator wenn Sie die Adresse des HTTP Servers nicht kennen Geben Sie im Textfeld Server TCP Port Eingabe des Ausgangs TCP Ports die HTTP Server Schnittstelle ein Werkeinstellung 80 HINWEIS Wenn Sie mit SSL Verschl sselung exportieren m chten geben Sie die TCP Port Nummer des HTTPS Servers ein die normalerweise 443 lautet Geben Sie im Textfeld Pfad den Pfad zu Eingabe des Server Script Pfads dem Server Script ein das der Webserver ausf hrt nachdem das EGX Daten an ihn ge
304. los temas que sean comunes a los dispositivos seleccionados 6 Seleccione Siguiente Abre la p gina de tendencias de Varios dispositivos Unico tema 7 Mantenga pulsado el bot n izquierdo del rat n y Aumenta la zona del gr fico arrastre un cuadro de selecci n alrededor de una seleccionada zona del gr fico para ampliarla 8 Para volver a la vista completa original escriba Z Se reduce el zoom de la vista en el teclado o haga doble clic sobre el gr fico El tema registrado de los dispositivos seleccionados se muestra en una p gina web en un formato de gr fico de tendencia del tiempo El gr fico de tendencia del tiempo est preconfigurado para mostrar los datos del ltimo d a completo la ltima semana completa el ltimo mes completo o todos los datos Los par metros de la energ a se visualizan como valores incrementales por intervalo Los otros par metros se registran y visualizan como el valor real registrado Figura 39 P gina de configuraci n de Varios dispositivos nico tema Select Devices and Topics Dispositivos disponibles Temas disponibles Building Main Energ a aparente kVAh Building West Panel nergia activa Building East Panel Energia react kVARh 2011 Schneider Electric Reservados todos los derechos 45 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Supervision 11 2011 Figura 40 Pagina de tendencias de Varios dispositivos Unico tema Energ a
305. m d appareil Saisit le nom de l appareil tapez le nom de l appareil 7 Dans la zone de texte Identification Configure l adresse locale de l appareil locale tapez l adresse de l appareil esclave s rie s il est raccord au port s rie ou saisissez l adresse que vous voulez utiliser pour acc der un appareil distant 8 Dans la zone de texte Identification Configure l adresse de l appareil distant distante tapez l adresse de l appareil distant 9 Recommencez les tapes 4 8 jusqu ce Saisit tous les appareils connect s que tous les appareils soient configur s 10 Cliquez sur Appliquer Actualise la liste des appareils Ce param tre de configuration peut tre modifi uniquement si l enregistrement des donn es est d sactiv pour l appareil mis jour Voir Journaux d appareil page 17 Figure 10 Page Liste des appareils Liste des appareils Nombre d appareils afficher 8 E _ Type d appareil Nom d appareil Identification locale PM800 E Pueoo_Blag Feeders 3 CM4000 E cia Bgt Maint A CM2000 E cu2_Bldg2_Feeder2 LE PM9c E Puoc_Bidg2 Feeder E Sepam 2000 Separr2_Bldg2_CB_1 7 Sepam Series 40 Sepam4_Bldgt _CB_2 LEZ Model98 modbus i Model98_Bldg1_Switchgear1 9 Modbus _ 8 m _ D tection Appliquer 2011 Schneider Electric Tous droits r serv s 13 Passerelle Ethernet PowerLogic EGX30
306. maximum of 20 connections are supported Click Active Connections to open a new window with a list of all of the active client connections Accumulative Connection A counter that increments each time a connection is made to the EGX Maximum Connections A status value that represents the maximum number of connections that were active at any given moment TClick the link for additional detailed information 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 PowerLogic Ethernet Gateway EGX300 Diagnostics 2011 Schneider Electric All Rights Reserved suis scription Gateway Information Firmware Version The firmware version that is installed on the ECK System Idle Time A percentage from 0 to 100 indicating the average processor time that is not being used MAC Address The unique Ethernet hardware address of an EGX The serial number of the EGX The EGX model number EGX hardware version Date the EGX was manufactured HTTP Client Send OK A counter that increments each time a file is sent successfully to the HTTP server Connect Error A counter that increments each time the EGX is unable to connect to the HTTP server Authentication Error A counter that increments each time the HTTP server is unable to authenticate the user or password credentials Send Error A counter that increments each time a file is unable to be transferred to the HTTP server General Error A counter
307. me Time Zone Parameters Time Zone Offset UTc 0600 Enable Automatic Daylight Savings Time Adjustment M Daylight Savings Time Begins Second El Sunday y of March qa oz 00 y Daylight Savings Time Ends First x Sunday y of November x at 02 00 y SNTP Parameters Poll Interval 1 hour y Primary NTP Server IP Address 10 168 108 m Secondary NTP Server IP Address 10 168 108 12 Last Successful Time Synchronization Date and Time 2011 11 17 15 09 45 Server IP Address 10 168 108 11 Apply Table 10 SNTP Parameters Settings option OS RE Time Zone Offset The time is set based on the Coordinated UTC 12 00 to UTC 13 00 Universal Time UTC value selected Default UTC GMT Enable Automatic Allows you to define when Daylight First to Fifth or Final Daylight Savings Savings Time begins and ends Sunday to Saturday Time Adjustment January to December 0 00 to 23 00 Default Begins Second Sunday of March at 2 00 Ends Second Sunday of November at 2 00 Poll Interval Controls how often the EGX contacts the 1 hour to 1 week NTP server for the correct time Default 1 week Primary NTP Server The IP address of the primary NTP server 0 0 0 0 to 255 255 255 255 IP Address the EGX contacts for the correct time Default 0 0 0 0 Secondary NTP The IP address of the secondary NTP 0 0 0 0 to 255 255 255 255 Server IP Address server the EGX co
308. men empfangen wird der die in den Standardeinstellungen festgelegte maximale L nge berschreitet Rahmen l nger als 1518 Byte Rahmen zu kurz Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen empfangen wird der die in den Standardeinstellungen festgelegte minimale L nge unterschreitet Rahmen k rzer als 64 Byte Modbus TCP IP Server Rahmen gesendet Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen gesendet wird Rahmen empfangen Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen empfangen wird Protokollfehler Z hler der sich jedes Mal um eins erh ht wenn eine Nachricht mit einem falschen Format empfangen wird Aktive Verbindungen Statuswert der die Anzahl der Verbindungen darstellt die zum Zeitpunkt der Aktualisierung der Diagnoseseite aktiv sind Es werden maximal 64 Verbindungen unterst tzt Durch Klicken auf Aktive Verbindungen wird ein neues Fenster mit einer Liste aller aktiven Client Verbindungen ge ffnet Summe der Verbindungen Z hler der sich jedes Mal um eins erh ht wenn eine Verbindung zum EGX aufgebaut wird Maximale Anzahl Verbindungen Statuswert der die maximale Anzahl von Verbindungen darstellt die aufgebaut werden Eingegangene Lesenachrichten Z hler der sich jedes Mal um eins erh ht wenn eine Lesenachricht empfangen wird Eingegangene Schreibnachrichten er der sich jedes Mal um eins erh ht wenn eine reibnachricht empfangen wird Abgegangene A
309. n Siguiente consulte la Figura 32 NOTA Haga clic en gt gt para seleccionar todos los dispositivos disponibles Figura 32 Pagina Selecci n de dispositivo Selecci n de dispositivo Dispositivos disponibles Dispositivos seleccionados Building Main Building West Panel Building East Panel Building North Panel O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 Tendencias Pasarela Ethernet EGX300 de PowerLogic Supervisi n Figura 33 P gina Resumen de circuito Resumen de circuito 2010 05 10 14 22 18 Dispositivos nuevos Dispositivo Intensidad RMS amperios Potencia activa kW Factor de potencia Estado del interruptor Building Main 383 301 0 927 retardo Building North Panel 166 132 0 941 cap Para visualizar una tendencia en tiempo real de varios dispositivos y temas vaya al men Supervisi n y seleccione Datos en tiempo real gt Tendencias 1 En el men Supervisi n seleccione Datos en tiempo Ampl a el rbol de datos para real seleccionar opciones de datos en tiempo real eccione Tendencias Ampl a el rbol de datos para seleccionar opciones de tiempo real correspondientes a las tendencias leccione Tendencias en tiempo real Abre la p gina de configuraci n Tendencias en tiempo real 4 Seleccione hasta cuatro dispositivos de la lista Selecciona los dispositivos Dispositivos disponibles cuyas tendencias se mostra
310. n kilobytes Free Space The total amount of unused disk space on the EGX disk in kilobytes Click the link for additional detailed information 53 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Diagnostics 11 2011 Read Device Registers This option allows the EGX to read from its local or remote devices Figure 48 Read Device Registers Page Read Device Registers Device Name Local ID Starting Register Number of Registers Select by Device ID j 1000 10 Register Value 1000 O Data Type 1001 0 Holding Registers Y 1002 0 003 a Decimal 004 0 Hexadecimal 005 0 Binary he BD ASCII 007 0 008 D Read 009 D 2 Enter local device ID or choose from the Enters the registers to read from the specified defined device list starting data address device and the number of registers to read Value column select Decimal Hexadecimal Binary or ASCII Selects a device to read from the list of previously added devices A device not defined in the device list can be read by entering its Local ID number D D read Starting Register The first register to read Number of Registers The number of registers to read 1 to 125 Register column Lists the register numbers Value column Lists the data stored for a register Values retrieved depend on the device connected to the EGX Refer to the documentation for the connected device for more information about stored register
311. n Meldungen E Mail Alle Meldungen werden mit einem Zeitstempel versehen und enthalten die Berichtsgruppe sowie die Benutzeridentifikation 33 PowerLogic Ethernet Gateway EGX300 Setup 34 63230 319 216B2 11 2011 Die Seite Pr fpfad ist in drei Bereiche unterteilt die den drei Meldungskan len entsprechen Wartungsprotokoll Syslog und E Mail Siehe Abbildung 28 auf Seite 35 Sie k nnen die auf jedem Kanal bertragenen Meldungen separat konfigurieren Klicken Sie im Fenster Setup auf Pr fpfad Die Seite Pr fpfad wird angezeigt Befolgen Sie die Anweisungen in der nachstehenden Tabelle Tabelle 14 Pr fpfadeinrichtung Wartungsprotokoll Steuerung der Meldungen werden im Onboard Aktivieren Sie die Optionen die Berichtstypen f r Wartungsprotokoll des EGX angezeigt im Bericht enthalten sein sollen die Meldungen im sobald sie generiert werden Werkeinstellung keine Meldungsprotokoll Optionen aktiviert angezeigt werden sollen Server IP Adresse Meldungen werden zu dem hier Geben Sie die IP Adresse f r angegebenen Server weitergeleitet den entfernten Server ein zu sobald sie generiert werden dem die Meldungen weitergeleitet werden sollen Server UDP Port Syslog Meldungen werden ber diesen Geben Sie die UDP Port User Datagram Server UDP Port bertragen Nummer f r diese IP Adresse Protocol ein Werkeinstellung 514 Bericht Hier werden die vier Berichtstypen f r d
312. n Min Max Min Max Min Max Min Max Building Main o 100 100 100 o 100 0 100 Building West Panel o 100 100 100 o 100 o 100 Building East Panel E o 100 100 100 o 100 E 100 Building North Panel o 100 100 100 o 100 o 100 Auf den bersichtsger teseiten befinden sich tabellarische bersichten ber ein oder mehrere ausgew hlte Ger te Klicken Sie im berwachungsmen auf bersichtsger teseiten W hlen Sie die bersichtsseite aus die Sie betrachten m chten W hlen Sie Ger te aus der Liste Verf gbare Ger te Auswahl von Ger ten f r die aus und klicken Sie auf Weiter siehe Abbildung 32 bersichtsoptionen HINWEIS Klicken Sie auf gt gt um alle verf gbaren Ger te auszuw hlen Abbildung 32 Seite Ger teauswahl Ger teauswahl Verf gbare Ger te Ausgew hlte Ger te Building Main Building West Panel Building East Panel Building North Panel gt lt lt O 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Trendverfolgung 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 berwachung Abbildung 33 Seite Schaltkreis bersicht Schaltkreis bersicht 2010 05 10 14 19 44 Neue Ger te Ger t Stromeffektivwert A Wirkleistung kW Leistungsfaktor LS Status Building Main 437 334 0 905 nacheilend
313. n der seriellen HINWEIS Beim Ubernehmen von Anderungen auf der Schnittstelle f r das EGX Seite Erweiterte Einstellungen der seriellen Schnittstelle werden diese nderungen nicht auf der Seite Serielle Schnittstelle gespeichert Abbildung 6 Seite Erweiterte Einstellungen der seriellen Schnittstelle Erweiterte Einstellungen der seriellen Schnittstelle Verz gerung zwischen Rahmen 50 v Millisekunden Verl ngerung des Stilleintervalls 6 v Zeichen Ausnahmefehlercode Modbus TCP IP Timeout 0x0B v Standardwerte bernehmen PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Tabelle 6 Erweiterte Einstellungen der seriellen Schnittstelle Verz gerung Hier wird das Mindeststilleintervall 0 bis 100 Millisekunden zwischen Rahmen zwischen dem Ende einer empfangenen Werkeinstellung Antwort und dem Beginn einer neuen 50 Millisekunden Anfrage auf der seriellen Leitung festgelegt Verl ngerung des Erlaubt die Verl ngerung des 0 bis 15 Zeichen Stilleintervalls Stilleintervalls zur Kennzeichnung des Werkeinstellung 6 Zeichen Endes eines Modbus RTU Pakets ber die standardm ig festgelegten 3 5 Zeichen hinaus Ausnahmefehler Hier wird der Ausnahmefehlercode Ox0A oder 0x0B code Modbus festgelegt der zur ckgesendet wird wenn Werkeinstellung Ox0B TCP IP Timeout ein an das EGX angeschlossenes serielles Ger t nicht vor der Zeit berschreitung der seriel
314. n forma de hipervinculo todos los dispositivos Schneider Electric detectados Al desplazar el rat n por encima de cualquier dispositivo de la lista se ven datos adicionales de este a la izquierda de la lista Haga clic sobre cualquier dispositivo para ir a su p gina de inicio de sesi n Figura 44 P gina Punto de acceso del sistema visualizaci n de datos de dispositivo Punto de acceso del sistema Plataforma EGX300 Direcci n MAC 00 80 67 80 5B 63 Nombre del equipo Direcci n IP i n del firmware 4000 len EGX300 169 254 0 20 Numero de serie 23395 Powerfogic EGX300 169 254 0 30 Tiempo de espera 10 Actualizar 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 11 2011 DOCUMENTACION CONTROL Pasarela Ethernet EGX300 de PowerLogic Documentaci n La pagina Documentaci n le permite acceder a informaci n que se ha almacenado como archivos en EGX y como vinculos web URL Para obtener informaci n sobre la carga de vinculos de documentaci n consulte Vinculos de documentaci n en la p gina 26 Si desea abrir un vinculo de documentaci n haga clic en el enlace Documentaci n situado en la parte superior de la p gina y despu s seleccione el vinculo que le interese Figura 45 P gina Documentaci n Schneider PowerLogic EGX300 Electric Inicio Documentaci n Desconexi n Diagn sticos Wantenimiento amp Documentaci n owerLog
315. nable all devices and Clear to disable all devices NOTE Device Type Availability may notbe changed for devices that are currently in use 3 Click Apply Saves the Viewable Device Type settings Figure 27 Viewable Device Types Page Viewable Device Types ne Device Type ATS48 ATV61 ATV71 Accusine a BCM BCPM Model A BCPM Model B del C The Audit trail is a time stamped sequence of records or messages It records configuration change error and failed authentication events and it identifies the user who initiated the event Use the Audit Trail page to set up the four report groups and message channels For each channel you choose the report group s for which you want to see messages When you choose a report group for a channel you will see any of the messages that are generated in that report group The message channels are EGX on board maintenance log file Remote Syslog server Syslog is a standard for logging messages e E Mail All messages are date time stamped and they include the report group and user identifying information 33 PowerLogic Ethernet Gateway EGX300 Setup 34 63230 319 216B2 11 2011 The Audit Trail page is divided into three boxes that correspond to the three message channels Maintenance Log Syslog and E Mail See Figure 28 on page 35 You can independently configure the messages that are sent to each channel From the Setup window cl
316. nce Tableaux de bord 46 11 2011 Figure 40 Page de calcul de tendance Plusieurs appareils une seule grandeur Energie active kWh Dernier jour complet iv Building East Panel Building North Panel 2010 02 16 06 2010 02 16 12 00 00 2010 02 16 18 00 00 2010 02 17 00 00 00 2010 02 17 06 00 00 Selectionnez la zone 4 agrandir Appuyez sur Z ou double cliquez pour annuler le zoom La passerelle EGX prend en charge quatre cat gories de tableau de bord affichant des informations de consommation d nergie agr g es sur la p riode Le Tableau 17 liste les tableaux de bord disponibles et leurs sous ensembles Tableau 17 Types de tableau de bord Tableau de bord Sous ensemble Par heure Jour pr c dent par heure Jour courant par heure Jour courant sur jour pr c dent par heure Semaine pr c dente par jour Semaine courante par jour Semaine courante sur semaine pr c dente par jour Mois pr c dent par jour Mois courant par jour Mois courant sur mois pr c dent par jour Par semaine Trimestre pr c dent par semaine Trimestre courant par semaine Trimestre courant sur trimestre pr c dent par semaine 13 derni res semaines par semaine Ann e pr c dente par mois Ann e courante par mois Ann e courante sur ann e pr c dente par mois REMARQUE Le fichier journal de chaque appareil doit pouv
317. nces Open Y OS ER Nom de l quipement Permet de personnaliser le nom de l EGX et Par d faut Powerlogic de l quipement associ Ce nom sera utilis dans la banni re de l interface Web Page d accueil par Permet de s lectionner la page d accueil Accueil d faut par d faut R capitulatif circuit R sum du courant de charge R capitulatif des val moyennes du courant R capitulatif puissance ou R capitulatif nergie Par d faut Accueil Fr quence D finit la fr quence de lecture des donn es 5 60 s d chantillonnage en du ou des appareils dans l affichage Par d faut 5 secondes temps r el standard des tableaux de surveillance Fr quence de D finit la fr quence laquelle les D sactiv 5 30 minutes v rification des communications sont v rifi es lorsque le Par d faut 15 minutes communications navigateur affiche des mesures en temps r el dans l affichage standard des tableaux de surveillance Cette fonction essaie de remettre automatiquement en service tout appareil hors service O 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Types d appareil affichables Piste d audit 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Configuration La page Types d appareil affichables permet de gerer les types d appareil s lectionnables par l utilisateur dans la page Liste des appareils tant donn
318. nd auf bernehmen Protokollierung des Ger ts nicht aktiviert sein Um die Aufzeichnung zu deaktivieren w hlen Sie ein Damit wird die Aufzeichnungsfunktion Aufzeichnungsintervall gleich null aus Die ausgeschaltet Aufzeichnungsoptionen m ssen deaktiviert sein Klicken Sie anschlie end auf bernehmen Abbildung 13 Seite Gerateaufzeichnung Ger teaufzeichnung Aufzeichnungsintervall 15 A Minuten Protokollierung Daten l schen Ger tebezeichnung Ger tetyp Alleausw hlen Alleausw hlen Anpassen Building Main CM4000 Y Themen Building West Panel CM2000 Y Themen Building East Panel CM3000 Themen Building North Panel PM800 Themen _Ubemenmen_ Gr en f r die Aufzeichnung k nnen f r jedes Ger t einzeln ausgew hlt werden 1 Klicken Sie auf der Seite Ger teaufzeichnung auf den Link Anzeige der Gr en f r das gew nschte Ger t Gr enauswahlseite 2 Beachten Sie Abbildung 14 und aktivieren Sie die Gr e n Auswahl der zu die Sie aufzeichnen m chten protokollierenden Gr en Um alle Gr en auszuw hlen klicken Sie auf Alle ausw hlen Um die Auswahl aller Gr en aufzuheben klicken Sie auf L schen Um die voreingestellten Gr en auszuw hlen klicken Sie auf Standardwerte 3 Klicken Sie auf bernehmen Speicherung der Auswahl der zu protokollierenden Gr en 2011 Schneider Electric Alle Rechte vorbehalten
319. ndant dans les zones de texte appropri es puis cliquez sur Connexion 3 Localisez le r pertoire du fichier de logiciel embarqu sur votre ordinateur egxxxxx bin cliquez avec le bouton droit sur le fichier puis cliquez sur Copier 4 Cliquez avec le bouton droit de la souris dans la fen tre de l Explorateur Windows puis cliquez sur Coller REMARQUE Au lieu de copier coller le fichier vous pouvez le faire glisser vers PExplorateur Windows 5 Localisez le fichier de mise jour egxxxxx upd sur votre ordinateur cliquez avec le bouton droit sur le fichier puis choisissez Copier 6 Cliquez avec le bouton droit de la souris dans la fen tre de l Explorateur Windows puis cliquez sur Coller REMARQUE Au lieu de copier coller le fichier vous pouvez le faire glisser vers PExplorateur Windows 7 Pour v rifier que la mise jour a r ussi suivez la proc dure d crite la section Recherche de la version du logiciel embarqu page 56 Ouvre la bo te de dialogue Connexion en tant que Ouvre une session FTP avec la passerelle EGX Copie le fichier dans le Presse papiers Copie le logiciel embarqu dans la passerelle EGX qui red marre REMARQUE Le voyant Alimentation tat clignote rapidement pendant que le fichier est transf r et programm sur la passerelle EGX la fin de la programmation l EGX red marre Le temps n cessaire la programmation est de 1 5 2 minutes
320. nderen PowerLogic Gateways und Modbus TCP IP Schnittstellen z B HH gt ECC21 und PM8ECC m Ger te in Webseiten 9 18 ION6200 PM800 Micrologic Sepam EGX100 EGX300 Unterlagen Rufen Sie die Website www powerlogic com auf und w hlen Sie Ihr Land Navigieren Sie zur Seite der EGX Dokumentation Firmware Rufen Sie die Website www powerlogic com auf und w hlen Sie Ihr Land Navigieren Sie zur Seite der EGX Downloads f r Einzelheiten siehe Neue Firmware herunterladen auf Seite 57 PowerLogic Ethernet Gateway EGX300 Zugang zum EGX ber ein Netzwerk ZUGANG ZUM EGX BER EIN NETZWERK Anmelden beim EGX 63230 319 216B2 11 2011 Nachdem Sie die EGX Ethernet Parameter eingerichtet haben siehe EGX Installationshandbuch k nnen Sie ber ein Ethernet LAN mit jedem g ngigen Webbrowser auf das EGX zugreifen 1 Starten Sie den Webbrowser Einblendung des Webbrowsers 2 Geben Sie in die Adressenleiste die Einblendung des Anmelde Dialogfeldes Adresse Ihres EGX ein 169 254 0 10 ist die Werkeinstellung und dr cken Sie die Eingabetaste 3 Geben Sie in die Textfelder Ihren Eingabe des Benutzernamens und des Benutzernamen Werkeinstellung Kennwortes und Einblendung der EGX Administrator und das Kennwort Startseite Werkeinstellung Gateway ein und klicken Sie auf OK HINWEIS Beim Benutzernamen und Kennwort wird zwischen Gro und Kleinschreibung unterschieden
321. nennnnnnennsnnnnnsnnnnnnnnennennnnn 37 Real Time Data vocoder 37 Single Device Pages fete sienne 37 Basic Readings Settings 37 Analog Gauge Range 38 Summary Device Pages 38 Trending scot eile Rn irre 39 Device Logging corista aa aaa 40 Single Device Pages ne nn less 41 Getting a D ta k g 2 2 2 ri 42 L g Formats ernennen Ben 42 Error Codes for Data Logs 43 2011 Schneider Electric All Rights Reserved i PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Contents 11 2011 Getting an Interval Data Log using FTP 43 Getting an Interval Data Log Using the Data Points Button 44 Getting an Interval Data Log Using the Microsoft Web Query Feature 44 Getting an Interval Data Log Using E mail 44 Getting an Interval Data Log Using HTTP 44 Summary Device Pages 45 Dashboard ius atadura naeh 46 Viewing a Dashboard esras a A T 47 Getting Dashboard Data Using the Data Points Button 48 Saving a Dashboard 48 System Access Point ner tr ternera 48 Documentation unesnssessnnennnnnnnnnnnennnnnennnnnnnnnsnnnnnnnnennnnnnnnsnnennnnnnnnnnnennnnn 49 COMMON AO 49 DIaghOStiCS oc cisiccsccectsisedeteccantacinvedatecvsdadsstsvadsuandseucdsessdedbadueissucussvaueineds 50 Statistics At in 50 Interpreting Statistics 51 Read Device Registers us 54 Communications Check eccceeceeeececceceeee
322. neuen Gruppennamens geben Sie den neuen Namen in eines der Textfelder Gruppen ein der Administrator Gruppenname kann nicht ge ndert werden 3 Geben Sie im Bereich Benutzer einen Namen Eingabe des Namens und des 1 bis 24 Zeichen und ein Kennwort 0 bis Kennwortes f r einen Benutzer 12 Zeichen f r einen neuen Benutzer ein Das EGX300 berpr ft die Sicherheit des HINWEIS Benutzernamen und Kennw rter Kennworts und zeigt diese durch einen ber cksichtigen Gro und Kleinschreibung und Farb sowie einen Textcode an k nnen nur alphanumerische Zeichen enthalten Rot kein Kennwort Kennwort mit niedriger Sicherheit Gelb Kennwort mit mittlerer Sicherheit Blau Kennwort mit hoher Sicherheit Gr n Kennwort mit sehr hoher Sicherheit 4 W hlen Sie eine Gruppe und die Auswahl der Gruppe und der Sprache f r Standardsprache f r den neuen Benutzer aus einen Benutzer 5 Wiederholen Sie die Schritte 3 und 4 f r jeden Hinzuf gen weiterer Benutzer zus tzlichen Benutzer den Sie hinzuf gen wollen 6 Klicken Sie auf bernehmen Sicherung aller Benutzerkonteneinstellungen Tabelle 11 EGX Konten und Kennw rter Amilo Benutzerdefinierte Konten bis zu 11 Konten m glich Keine Werkeinstellung Kennwort ist benutzerdefiniert Abbildung 23 Seite Benutzerkonten Benutzerkonten Gruppen Engineering Operations Maintenance Benutzer Name Kennwort Gruppe Sprache Deutsc
323. nfiguration Synchronisation de l heure r seau 24 63230 319 216B2 11 2011 La synchronisation de l heure r seau permet de r gler la date et l heure de l horloge du syst me EGX l aide d un serveur NTP Network Time Protocol REMARQUE Si le serveur NTP ne se trouve pas sur le m me segment de r seau Ethernet que la passerelle EGX assurez vous que les param tres de passerelle EGX par d faut sont correctement configur s S lectionnez la case cocher Activer Affiche les param tres SNTP ainsi que la synchronisation de l heure r seau de la derni re synchronisation horaire r ussie page Date et heure 2 Configurez le d calage horaire la p riode R gle les param tres SNTP de scrutation et l adresse IP des serveurs NTP primaire et secondaire voir le Tableau 10 3 Cliquez sur Appliquer Enregistre la configuration SNTP Figure 19 Activation de la synchronisation de l heure r seau Date et heure Activer synchronisation de l heure r seau Date Heure Param tres horaires D calage horaire UTC 06 00 he Activer le r glage automatique de l heure d t C D but de l heure d t de Fin de l heure d t de Param tres SNTP P riode de scrutation 1 heure y Adresse IP du serveur NTP primaire D 0 0 0 Adresse IP du serveur NTP secondaire 0 0 0 o Derni re synchronisation horaire r ussie Date et heure Adresse IP du serveur
324. ngsstufe zuweisen die Modbus TCP IP Clients auf die an das EGX angeschlossenen Ger te lokal oder entfernt haben HINWEIS Der anonymen Modbus TCP IP Adresse k nnen die Zugriffsberechtigungen Schreibgesch tzt oder Keine zugewiesen werden Die Einstellung Schreibgesch tzt erlaubt jedem Modbus TCP IP Client der nicht in der Filterliste enthalten ist den Zugriff auf serielle Slave Ger te mit der Zugriffsberechtigung Schreibgesch tzt Die Einstellung Keine blockiert alle Modbus TCP IP Clients die nicht in der Filterliste enthalten sind 1 Klicken Sie im Setup Men auf Modbus Einblendung der Seite Modbus TCP IP Filter TCP IP Filter 2 Markieren Sie Filter aktivieren Aktivierung der Filterung 3 Geben Sie in der Spalte IP Adresse die Eingabe einer IP Adresse f r einen Modbus Modbus TCP IP Client Adresse ein TCP IP Client der Zugriff auf die an das EGX angeschlossenen Ger te haben soll 4 W hlen Sie in der Spalte Auswahl der Zugriffsberechtigung f r die Zugriffsberechtigung entweder entsprechende IP Adresse F r die Einstellung Schreibgesch tzt oder Vollst ndig aus Schreibgesch tzt sind die folgenden Modbus TCP IP Funktionen erlaubt Dezimal 1 2 3 4 7 8 11 12 17 20 24 43 100 Hexadezimal 01 02 03 04 07 08 OB OC 11 14 18 2B 64 25 PowerLogic Ethernet Gateway EGX300 Setup Unterlagenlinks 26 63230 319 216B2 11 2011
325. nico 44 mediante FTP 43 mediante funci n de consulta Web de Microsoft 44 mediante HTTP 44 de dispositivos 17 40 de mantenimiento 56 historial de auditor a 34 formato de datos 42 temas 18 registros de dispositivo lectura 54 S seguridad de la contrase a indicaci n crom tica 28 sincronizaci n horaria de red configuraci n 24 supervisi n 37 Syslog historiales de auditor a 34 T tendencias 39 tipos de dispositivos admitidos 60 tipos de dispositivos visualizables 33 V versi n del firmware del componente binario ejecutable 57 versi n del firmware del componente de imagen de archivo 57 vinculos de documentaci n configuraci n 26 visualizaci n de datos y tendencias en tiempo real 37 63 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 indice alfab tico 11 2011 64 2011 Schneider Electric Reservados todos los derechos Pasarela Ethernet EGX300 de PowerLogic Manual del usuario Schneider Electric 295 Tech Park Drive Suite 100 La Vergne TN 37086 EE UU Para obtener asistencia t cnica Global PMC Tech support schneider electric com 00 1 250 544 3010 P ngase en contacto con su distribuidor local de Schneider Electric para obtener asistencia o visite el sitio web www schneider electric com PowerLogic es una marca comercial de Schneider Electric Cualquier otra marca comercial citada es propiedad de sus respectivos propietarios S lo el personal cualificado debera in
326. nn es de la page passerelle EGX Param tres avanc s du port s rie ne valide aucune des modifications apport es la page Port s rie Figure 6 Page des param tres avanc s du port s rie Param tres avanc s du port s rie D lai d attente entre trames 50 x millisecondes Extension de l intervalle de silence 6 v Caract res Code d erreur de d lai d attente Modbus 0x0B Appliquer Valeurs par d faut 2011 Schneider Electric Tous droits r serv s 9 Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Configuration 11 2011 Tableau 6 Param tres avanc s du port s rie onion T ness Va EE Delai d attente D finit l intervalle de silence minimal entre 0 a 100 millisecondes entre trames la fin de la r amp ponse recue et le debut d une Par defaut 50 millisecondes nouvelle requ te sur la ligne s rie Extension de Permet d tendre au del des 0 15 caract res l intervalle de 3 5 caract res normaux l intervalle de Par d faut 6 caract res silence silence charg de marquer la fin d un paquet Modbus RTU Code d erreur de Indique le code d erreur renvoy lorsqu un 0x0A ou 0x0B d lai d attente appareil s rie connect la passerelle Par d faut 0x0B Modbus TCP IP EGX ne r pond pas dans le d lai pr vu pour le port s rie Pour Modbus TCP IP ce code est 0x0B Dans certaines suites logicielles plus anciennes le code tait Ox0A Connexions d
327. nner les grandeurs par d faut cliquez sur Valeurs par d faut 3 Cliquez sur Appliquer Enregistre dans le journal les grandeurs s lectionn es 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Configuration Figure 14 Page de s lection des grandeurs Nom d appareil Type d appareil Building North Panel PM800 3 Activ _ Activ intervalles 57024 hector foul finger Nom de valeur Ben 7 nergie apparente kVAh Intervalle d enregistrement 15 minutes Energie active KWh Energie r active KVARh Puissance apparente totale kVA s E Puissance active totale kW Puissance r active totale KVAR Valeur moyenne puissance active KW Valeur moyenne puissance r active kVAR Val moyenne du courant 1 Val moyenne du courant 2 Val moyenne du courant 3 Val moyenne du courant 1 Dernier Val moyenne du courant 2 Dernier O Val moyenne du courant 3 Dernier Courant 1 Courant 2 Courant 3 Moyenne courant Tension 1 2 Tension 2 3 Tension 3 1 Tension moyenne L L Tension 1 N Tension 2 N Tension 3 N Tension moyenne L N Valeurs par d faut Appliquer Exporter le journal de l appareil Cette fonction permet d exporter les journaux
328. nnez les pages Web que vous souhaitez rendre disponibles pour les utilisateurs D s lectionnez les pages qui ne doivent pas tre visibles REMARQUE Lorsque vous d s lectionnez une page Web elle n est pas supprim e de la passerelle EGX 4 Cliquez sur Appliquer Ajoute ou supprime une page personnalis e de l interface Web EGX Figure 25 Page Ajouter Supprimer des pages Web Ajouter Supprimer des pages Web Surveillance Commande Maintenance device shtml 2011 Schneider Electric Tous droits r serv s 31 Passerelle Ethernet PowerLogic EGX300 Configuration Preferences 32 63230 319 216B2 11 2011 Cette option permet de personnaliser les passerelles EGX individuellement 1 Dans le menu Configuration cliquez sur Ouvre la page Pr f rences Preferences 2 Saisissez le nom de l quipement la page Definit les pr f rences d accueil par d faut la fr quence d chantillonnage en temps r el ainsi que la fr quence de v rification des communications 3 Cliquez sur Appliquer Met jour les param tres de pr f rences de la passerelle EGX Figure 26 Page Pr f rences Pr f rences Nom de l quipement Page d accueil par d faut Accueil v Fr quence d chantillonnage en temps r el 5 x Secondes Fr quence de v rification des communications Minutes Tableau 13 Param tres de pr f re
329. nt Entrez l adresse IP du serveur r exp di s au serveur que vous distant auquel vous souhaitez sp cifiez r exp dier les messages Port UDP User Les messages Syslog seront Entrez le num ro de port UDP Datagram Protocol du envoy s depuis ce port UDP du pour cette adresse IP Par serveur serveur d faut 514 Rapport Les quatre types de rapport pour Cochez les types de rapport lesquels des messages peuvent tre pour lesquels vous souhaitez r exp di s r exp dier des messages Liste d roulante Donne une indication approximative S lectionnez la cat gorie Installation de l origine du message au sein du appropri e syst me Cette information appara tra dans le journal Syslog Liste d roulante Gravit Indique l utilisateur l importance S lectionnez la cat gorie relative du message Vous devez appropri e d terminer l importance de chaque type pour votre site Courrier lectronique De l adresse L adresse lectronique de Sp cifiez l adresse de l exp diteur appara tra dans le l exp diteur des courriers champ De des messages lectroniques dans le champ g n r s pr vu cet effet Maximum Le corps du message contiendra les 49 caract res informations suivantes adresse IP de l EGX nom du groupe de rapports nom de l utilisateur adresse IP de l utilisateur et message du groupe de rapports Aux adresses Les messages g n r s seront Sp cifiez l adresse de envoy s la ou aux a
330. ntacts for the correct Default 0 0 0 0 time 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 SNMP Parameters Modbus TCP IP Filtering 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup The EGX supports SNMP allowing a network administrator to remotely access an EGX with an SNMP manager and view the networking status and diagnostics of the EGX in the MIB II format 1 From the Setup menu click SNMP Parameters Opens the SNMP Parameters page 2 Check Enable SNMP to turn ON the simple Activates SNMP network management protocol 3 Enter the system contact system name system Enters the SNMP system information and location read only community name and the community access names read write community name 4 Click Apply Saves the SNMP settings Figure 20 SNMP Parameters Page SNMP Parameters Enable SNMP x System Contact Admin System Name John Smith System Location US Office 1 Read only Community Name public Read write Community Name private This function allows the administrator to assign the level of access Modbus TCP IP clients have to the devices local or remote connected to the EGX NOTE There is an anonymous Modbus TCP IP address that can be set to Read only or None Setting it to Read only allows any Modbus TCP IP client not in the f
331. ntwortnachrichten Z hler der sich jedes Mal um eins erh ht wenn eine Antwortnachricht gesendet wird Rahmen gesendet Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen gesendet wird Rahmen empfangen Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen empfangen wird Protokollfehler Z hler der sich jedes Mal um eins erh ht wenn eine Nachricht mit einem falschen Format empfangen wird Klicken Sie f r weitere ausf hrliche Informationen auf den Link 51 PowerLogic Ethernet Gateway EGX300 Diagnose 52 63230 319 216B2 11 2011 Zeit berschreitungen Z hler der sich jedes Mal um eins erh ht wenn eine Anforderungsnachricht gesendet wird ohne dass eine entsprechende Antwortnachricht innerhalb der zul ssigen Zeit empfangen wird Zeit berschreitungen sind normalerweise das Ergebnis von Konfigurationsfehlern oder einer fehlenden Reaktion des Ger ts Verbindungszeit berschreitungen Z hler der sich bei jedem Verbindungsausfall um eins erh ht Ausnahmen empfangen Z hler der sich jedes Mal um eins erh ht wenn eine Ausnahme empfangen wird Abgegangene Lesenachrichten Z hler der sich jedes Mal um eins erh ht wenn eine Lesenachricht gesendet wird Abgegangene Schreibnachrichten Z hler der sich jedes Mal um eins erh ht wenn eine Schreibnachricht gesendet wird Eingegangene Antwortnachrichten Z hler der sich jedesmal um eins erh ht wenn eine Antwortnachricht empfangen
332. o para los dispositivos seleccionados 4 Haga clic en Aplicar Actualiza la configuraci n del registro de dispositivos de la EGX OPCIONES Si desea personalizar el contenido del registro habilite el Selecciona los temas de registro de dispositivos y a continuaci n lleve a cabo lo dispositivos que se tienen que siguiente registrar y luego vuelve a la p gina principal Registro de dispositivos Seleccione un intervalo de registro que no sea cero y desactive la casilla Registro del dispositivo espec fico Bajo Personalizar haga clic en el v nculo temas correspondiente al dispositivo que desee configurar Consulte la Figura 14 y marque los temas que desee registrar Para seleccionar todos los temas haga clic en seleccionar todo y a continuaci n haga clic en Aplicar Para cancelar la selecci n de todos los temas haga clic en borrar y a continuaci n haga clic en Aplicar Para seleccionar los temas predeterminados haga clic en Predeterminados en la parte inferior de la pantalla NOTA Si cambia los temas predeterminados registrados relativos a un dispositivo aparece un asterisco junto a temas en la columna Personalizar correspondiente a ese dispositivo El cambio de los temas de un registro de dispositivos que ya haya estado activo borrar todos los datos previamente registrados para este dispositivo Cuando sea necesario los datos deben recuperarse de la EGX antes de hacer los cambios P
333. o 150 0 0 2009 01 08 19 05 00 348 0 150 0 2011 Schneider Electric Reservados todos los derechos 41 Pasarela Ethernet EGX300 de PowerLogic M Supervisi n Obtenci n de registros cronol gicos de datos Formato de registro 42 63230 319 216B2 11 2011 Se pueden recuperar registros de datos de intervalo utilizando los m todos descritos en la Tabla 15 Tabla 15 M todos de recuperaci n de registros de datos de intervalo y formatos de archivo M todo de recuperaci n Formato de archivo recuperado FTP Variable separada por coma CSV Bot n Puntos de datos HTML Consulta Web de Microsoft HTML HTTP CSV Para ver una lista de todos los archivos de registros disponibles siga los pasos 2 a 4 de la secci n Obtenci n de un registro de datos de intervalo mediante FTP en la p gina 43 Los archivos tendr n el siguiente formato Nombre del dispositivo_ID local csv donde Nombre del dispositivo es el nombre dado al dispositivo esclavo e ID local es el identificador local num rico asignado a este Por ejemplo un dispositivo llamado Entrada de servicios del edificio 1 con un identificador local de 3 ser a Entrada de servicios del edificio 1_3 csv Cuando se exportan archivos de registros la fecha y la hora se a aden al nombre del archivo en el formato siguiente AAAAMMDDHHMMSS Por ejemplo Entrada de servicios del edificio 1_3_20100218115216 csv Esto indica qu
334. o de mantenimiento 4 Para agregar una nueva entrada de Abre la p gina A adir entrada de registro y registro haga clic en A adir entrada de permite al usuario introducir los detalles de registro y luego introduzca el texto de mantenimiento mantenimiento en el cuadro de texto Detalle de entrada consulte m s adelante la Figura 51 Figura 50 Registro de mantenimiento Registro de mantenimiento Eliminar entradas Eliminarregistro Afadir entrada de registro Eliminar Fecha y hora Usuario Detalle de entrada 2010 05 10 14 11 Administrator S Test Figura 51 A adir entrada de registro Registro de mantenimiento Fecha y hora Usuario Detalle de entrada 2009 01 12 15 58 Administrator El firmware de la EGX se puede actualizar utilizando el protocolo de transferencia de archivos FTP Consulte con el sitio www powerlogic com o con su distribuidor local para obtener la ltima actualizaci n del firmware La EGX consta de dos componentes de firmware el componente binario ejecutable y el componente de imagen de archivo O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Firmware Version del firmware del componente binario 1 Abra el explorador web e inicie una sesi n Abre la p gina de inicio de la EGX en la EGX 2 Localice la versi n del firmware en la parte Se
335. o serie Configuraci n avanzada del puerto serie C digo de excepci n de tiempo de espera Modbus TCP IP Retardo entre tramas 50 Extensi n de intervalo silencioso 6 0x0B Milisegundos Mi Caracteres xj Predeterminados Aplicar 2011 Schneider Electric Reservados todos los derechos Pasarela Ethernet EGX300 de PowerLogic M Configuraci n Conexiones con dispositivos remotos 10 63230 319 216B2 11 2011 Tabla 6 Configuraci n avanzada del puerto serie Opci n Descripci n Valor Retardo entre Define el intervalo silencioso minimo entre 0 a 100 milisegundos tramas el final de la respuesta recibida y el Predeterminado comienzo de una nueva solicitud en la 50 milisegundos linea serie Extension de Permite que el intervalo silencioso utilizado 0 a 15 caracteres intervalo para marcar el final de un paquete Predeterminado 6 caracteres silencioso ModbusRTU se amplie mas alla de los 3 5 caracteres definidos por la norma C digo de Indica el c digo de respuesta de excepci n 0x0A o 0x0B excepci n de que se devuelve cuando un dispositivo Predeterminado 0x0B tiempo de espera serie conectado a la EGX no responde Modbus TCP IP antes del tiempo de espera del puerto serie Modbus TCP IP utiliza OxOB Sin embargo en algunas suites de software anteriores se utilizaba Ox0A La EGX permite abrir conexiones para un m ximo de 16 dispositivos nicos Mod
336. ocal Time Stamp Apparent Energy kVAh Real Energy kWh Reactive Energy kVARh 8 0 360 02 12 2010 13 20 2708484 084 2436019 161 1160734 726 9 0 360 02 12 2010 13 25 2708509 192 2436042 802 1160743 04 10 o 360 02 12 2010 13 30 2708534 061 2436066 114 1160751 553 11 0 360 02 12 2010 13 35 2708559 927 2436090 052 1160761 238 12 0 360 02 12 2010 13 40 2708586 181 2436114 595 1160770444 13 0 360 02 12 2010 13 45 2708612 19 2436138 843 1160779 716 14 0 360 02 12 2010 13 50 2708637 907 2436162 783 1160788 984 15 0 360 02 12 2010 13 55 2708663 298 243618645 1160798 048 Error Codes for Data Logs The below error codes may be seen when troubleshooting data logs see Figure 36 on page 41 and Figure 37 on page 41 er Definition Code 19 Communication Error occurred for example CRC Logging is left enabled unless protocol or exception the last interval was missed 25 Timeout occurred when a request was sent without Logging is left enabled unless receiving a corresponding response within the the last interval was missed allowed time Interval time expired before data could be recorded Missed interval Contact Technical Support if you need assistance in resolving these or other error conditions Getting an Interval Data Log using FTP You can use FTP to retrieve a data log file by connecting to the EGX via FTP and transferring the csv file as shown in the steps below NOTE If you want the EGX to automatically send the data log file via FTP th
337. of energy consumption information aggregated over time for all devices enabled for data logging System Access Point The System Access Point page displays EGX300s and other networked system devices that are accessible from this EGX300 Each line is a hyperlink to the EGX300 log in page wo wo a wo wo gt gt gt 00 o o N Documentation Documentation Accesses relevant EGX documentation and user 49 configured documentation links Control Resets Provides for the execution of resets defined for the device and displays the date and time each reset function was performed Date and time resets are shown only when the device supports them PowerLogic Ethernet Gateway EGX300 63230 319 216B2 EGX User Interface Overview 11 2011 Table 1 EGX Pages Diagnostics Statistics Displays diagnostic data used to troubleshoot network 50 problems This page also contains information about your specific EGX including the serial number manufacturing date and Media Access Control MAC address Read Device Registers Allows users to read register data from local and remote 54 devices connected to the EGX 5 Communications Check Verifies the communications health of all devices 5 configured on the EGX Maintenance Maintenance Log Shows the date time and user who last performed 56 maintenance on the equipment and provides entry detail on the maintenance performed 4 2011 Schneider Electric All Rights Reserv
338. ogic Ethernet Gateway EGX300 Monitoring Viewing a Dashboard 2011 Schneider Electric All Rights Reserved From the Monitoring menu click Displays dashboard menu see Figure 41 Dashboards Select a device from the Device drop down Selects device for displaying data list NOTE The dashboard displays data from a single device Select a topic from the Topic Name drop Selects topic to be graphed down list NOTE Topics are limited to incremental consumption topics provided by the device Select time parameters from the Time drop Selects time range of logged data for selected down list topic Click Apply Opens the selected dashboard Figure 41 Dashboards Menu Dashboards Device Assembly Pni PM8 y Topic Name Real Energy kWh y Time Present Day over Past Day by Hours X The data from each dashboard displays in a web page in bar graph format As you hover over a bar in the graph the data point value for the selected interval displays Figure 42 Figure 42 Dashboard Graph pe Pnl paet Real Energy kWh Present Day over Past Day by Hours Present Day ne m 2 a 7 1 4 5 4 j 6 gt 3 WOOF 13 14 son 1819 23 Hours Figure 43 Dashboard Table Assembly Pni PM8 Real Energy kWh Present Day over Past Day by Hours Sun Nov 20 00 00 00 CST 2011 Sun Nov 20 01 00 00 CST 2011 Sun Nov 20 01 00 00 CST 2011 Sun Nov 20 02 00 00 CST 2011 Sun Nov 2
339. oir contenir deux ans de donn es historiques Voir Enregistrement des donn es par intervalle page 17 pour plus d informations 12 derniers mois par mois 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Affichage d un tableau de bord Passerelle Ethernet PowerLogic EGX300 Surveillance Action Resultat Depuis le menu Surveillance cliquez sur Tableaux de bord Affiche le menu de tableau de bord voir Figure 41 Selectionnez un appareil dans la liste d roulante Appareil REMARQUE Chaque tableau de bord affiche les donn es d un m me appareil S lectionne le p riph rique dont les donn es seront affich es S lectionnez une grandeur dans la liste d roulante Nom de grandeur REMARQUE Seules les grandeurs de consommation incr mentales fournies par l appareil sont concern es ici S lectionne les grandeurs tracer S lectionnez les param tres temporels dans la liste d roulante Heure S lectionne la p riode de donn es enregistr es pour la grandeur s lectionn e Cliquez sur Appliquer Ouvre le tableau de bord s lectionn Figure 41 Menu de tableau de bord Tableaux de bord Appareil Pmssso 1032 y Nom de grandeur Energie active kWh Fa Heure Jour en cours sur jour pr c dent par heure Appliquer Les donn es de chaque tableau de bord s affichent sur une page Web sous la forme d un graphiqu
340. on Vab 3 434 494 Voc 485 489 48 Vca 485 420 43 LL moyen 433 438 497 Van a7 280 285 Von 278 281 288 Ven 281 284 289 VIN moyen 273 22 287 Fr quence Hz 29 80 02 80 08 la 203 205 788 2008 08 10 12 58 20 2008 05 28 15 41 15 lo 25 247 782 2008 08 04 12 52 53 2008 05 28 15 41 15 lo 331 333 801 2008 08 10 12 57 05 2008 06 28 15 41 15 Val moyenne de la puissance Active kW 2e 206 314 2010 02 11 12 20 48 2010 0201 00 00 00 R active kVAR ES 14 2010 02 03 14 37 37 2010 02 01 00 00 00 Apparente kVA 24 284 245 2010 0203 14 37 37 2010 02 01 00 00 00 Energie active kWh 24456748 2008 01 21 10 58 05 Energie r active kVARh 1167057 2 2009 01 21 10 58 05 Energie apparente kVAh 2Z722584 7 2009 01 21 10 58 05 2011 Schneider Electric Tous droits r serv s 37 Passerelle Ethernet PowerLogic EGX300 Surveillance Plage des cadrans analogiques Pages r capitulatives appareils 38 63230 319 216B2 11 2011 La plage affich e sur les cadrans analogiques de la page Mesures de base peut tre configur e ou mise l chelle automatiquement voir Figure 31 Sous Activer la mise l chelle automatique cochez Active la mise l chelle les appareils dont les cadrans doivent tre r gl s automatique pour les appareils automatiquement s lectionn s REMARQUE Cliquez sur s lectionner tout pour activer la mise l chelle automatique pour tous les appareils et sur effacer pour la d
341. on pour entrer l adresse IP de groupe et d autres informations connexes 1 Dans le menu Configuration cliquez sur Affiche la fen tre Point d acc s syst me Point d acc s syst me 2 Activ Lorsque cette option est coch e les passerelles EGX300 affect es la m me adresse IP pourront se d tecter entre elles Valeur par d faut Activ 3 Port UDP Entrez le num ro entre 1 et 65535 du port UDP utilis pour la d tection par Point d acc s syst me Valeur par d faut 59 35 Passerelle Ethernet PowerLogic EGX300 Configuration 4 Adresse IP de groupe Intervalle Hello Temps de retenue Dur e de vie pour multidiffusion Communaut 9 Valeurs par d faut Appliquer 63230 319 216B2 11 2011 Tapez l adresse IP du groupe Il peut s agir d une adresse pour multidiffusion ou monodiffusion Valeur par d faut 224 0 1 2 Intervalle entre deux messages Hello envoy s par cette passerelle EGX300 pour annoncer sa pr sence aux autres appareils Schneider Electric d tect s par le Point d acc s syst me sur le r seau Plage 1 65535 secondes Valeur par d faut 300 secondes D lai d attente maximum apr s le dernier message Hello envoy par cette EGX300 avant que les autres appareils ne la consid rent comme indisponible Plage 2 65535 secondes Valeur par d faut 600 secondes Vous pouvez sp cifier la portion du r seau sur laquelle portera la d tection des autres ap
342. onse from a serial device Default 3 seconds Available only if the physical interface and transmission mode is RS232 Modbus ASCII CAUTION IMPAIRED NETWORK PERFORMANCE Only qualified workers should modify the advanced serial port settings of the EGX Such modifications should be performed only after reading about and understanding the advanced serial port settings Failure to follow these instructions can impair serial communication performance 1 Click Advanced on the Serial Port page Opens the Advanced Serial Port Settings page 2 Configure the advanced serial port settings Sets up the advanced serial port settings see Table 6 on page 11 for available options Click Defaults to select the default values for all options 3 Click Apply Updates the EGX advanced serial port settings NOTE Applying changes to the Advanced Serial Port Settings page does not save changes to the Serial Port page Figure 6 Advanced Serial Port Page Advanced Serial Port Settings Delay Between Frames 150 Milliseconds Silent Interval Extension E M Characters ModbusTCP IP Timeout Exception Code 0 08 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Setup 11 2011 Table 6 Advanced Serial Port Settings option Besen ME DE Delay Between Defines the minimum silent time between 0 to 100 milliseconds Frames the end of a received response and the Default 50 milliseconds b
343. ormat 42 Gr en 18 Aufzeichnungsintervalle 17 B Benutzerdefinierte Webseiten Einrichten 30 Benutzerkonten Einrichten 28 Benutzeroberfl che EGX 3 D Datenprotokoll Abrufen 42 Fehlercodes 43 FTP Abruf 43 Datenprotokollformat 42 Datum und Uhrzeit Einrichten 23 E Echtzeitdaten 37 EGX Anmeldung 2 Benutzeroberfl che 3 Ger teliste 12 Einf hrung 1 Einrichten EGX 5 Ger teliste 13 Einstellungen der seriellen Schnittstelle Erweitert 9 Einzelger teseiten 37 41 E Mail Ger teprotokollexport 19 Intervalldatenprotokoll 44 Erkennung identischer IP Adressen 8 Ethernet und TCP IP Einstellungen 5 Ethernet Einstellungen Erweitert 6 Ethernet Protokolle 59 Exportieren des Ger teprotokolls 19 F Fehlercodes Datenprotokoll 43 Firmware Aktualisieren 58 Aktualisieren ber FTP 56 Neu herunterladen 57 Firmwareversion Ausf hrbaren Bin rkomponente 57 Datei Image Komponente 57 FTP Datenprotokollabruf 43 Ger teprotokollexport 21 Hinzuf gen von Webseiten 30 L schen von Webseiten 30 G Ger teaufzeichnung 17 40 Ger teerkennung 15 Ger teliste EGX 12 Ger teprotokollexport Einrichten 19 Ger teregister Lesen 54 Ger tetypen unterst tzt 60 Grundmesswerteinstellungen 37 H Hardware 59 HTTP Abrufen eines Intervalldatenprotokolls 44 Export Ger teprotokoll 22 Port Nummer Einrichten 7 HTTPS Port Nummer Einrichten 7 Instrumententafeln 46 Intervalldatenprotokoll E Mail 44 FTP 43 HTTP
344. otamente Almacena los datos registrados en archivos FIFO Primero en entrar primero en salir no vol tiles La capacidad de registro de cada archivo de registro cronol gico de datos es variable y depende del intervalo de registro seleccionado Dicha capacidad se calcula dividiendo el n mero m ximo de intervalos registrados que puede albergar un archivo de registro 171 072 entre el producto del n mero de temas registrados por los intervalos registrados diariamente Capacid archivo de reg Intervs m x temas por interv x intervalos reg a diario Por ejemplo la capacidad del registro cronol gico de datos de un dispositivo que almacena tres temas cada 10 minutos se calcular a de la siguiente manera Intervalos registrados diariamente Minutos del dia intervalo de registro en min 1140 10 144 intervalos Capacidad del archivo de registro M ximo de intervalos posibles temas registrados por intervalo x intervalos registrados diariamente 171072 3 x 144 396 dias La capacidad de registro se calcula dinamicamente y se muestra en la pagina de selecci n de temas consulte la Tabla 9 para ver algunos ejemplos Tabla 9 Intervalos de registro de muestreos Capacidad de registro en d as de los intervalos de registro designados Intervalo de 5 min Intervalo de 10 min Intervalo de 15 min 594 1188 1782 297 594 891 N de temas 148 297 Configurar registro por intervalos Cada dispositivo incluido en
345. ou added custom web pages to any of Selects or deselects a custom web page the EGX folders you will see a list of file names underneath the name of each folder Select the web pages you want your users to see Deselect web pages you do not want your users to See NOTE Deselecting a web page does not delete it from the EGX 4 Click Apply Adds or removes a custom web page from the EGX web interface Figure 25 Add Remove Web Pages Page Add Remove Web Pages Monitoring Control Maintenance Y Instantaneous Readings shtn 31 PowerLogic Ethernet Gateway EGX300 Setup Preferences 32 63230 319 216B2 11 2011 This option allows each EGX to be individually customized 1 From the Setup menu click Preferences Opens the Preferences page 2 Enter the equipment name default home Sets the preferences page real time sample rate and communications check rate 3 Click Apply Updates the EGX Preferences settings Figure 26 Preferences Page Preferences Equipment Name Default Home Page Home x Real Time Sample Rate 5 x Health Check Rate disabled M seconds minutes Table 13 Preferences Settings ACTOS EE TI Equipment Name Allows you to enter a custom name for Default Powerlogic the EGX and associated equipment This EGX300 name will be used in the web interface banner Default Home Page
346. ow 5 A topic ID is a numerical reference to the quantity being logged The name given to a quantity may differ slightly between devices and languages Topic IDs are used to identify the quantity regardless of the device or language The first three commas are used for layout purposes in a spreadsheet application 1617 1621 1625 This row contains the topic IDs of the values logged Error UTC Offset Minutes Local Time This row contains the column headings Stamp Apparent Energy kVAh Real Energy for the data logged in rows 8 and higher kWh Reactive Energy kVARh These rows contain the logged data 0 300 2008 10 09 14 15 00 1400738 219 1201962 707 647069 906 15 0 300 2008 10 09 14 20 00 1400758 260 1201980 725 647078 602 15 0 300 2008 10 09 14 25 00 1400778 198 1201998 661 647087 233 15 If you use a spreadsheet application to view the CSV file your data should look similar to Figure 38 on page 43 2011 Schneider Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Monitoring Figure 38 Interval Data Log Opened in a Spreadsheet Application A B ne D E E eG a 1 Gateway Name Gateway SN Gateway IP Address Gateway MAC Address Device Name Device Local ID Device Type ID Device Type Name Log Interval 2 EGX300 0 157 198 184 125 00 80 67 80 5B 61 Building Main 1 5 CM4000 5 3 4 Topic ID 1 Topic ID 2 Topic ID 3 5 1617 1621 1625 6 7 Error UTC Offset Minutes L
347. pareils Cette valeur est d termin e par le nombre de fois que la multidiffusion peut tre r exp di e aux autres appareils Plage 1 255 sauts de routeur Valeur par d faut 1 Les passerelles EGX300 d un groupe peuvent tre r parties en communaut s Les passerelles EGX300 affect es la m me adresse IP et au m me num ro de communaut pourront se d tecter entre elles Si vous r glez le num ro de communaut sur 0 la passerelle pourra d tecter toutes les autres passerelles EGX300 ayant la m me adresse IP quel que soit le param tre de communaut Valeur par d faut 0 Cliquez sur Appliquer pour enregistrer vos s lections Cliquez sur Valeurs par d faut pour r tablir les valeurs initiales Figure 29 Page de configuration du Point d acc s syst me Point d acc s syst me Activ Port UDP Adresse IP de groupe Intervalle Hello Temps de retenue Dur e de vie pour multidiffusion Communaut Ca 59 224 0 1 2 1 85535 300 600 1 0 1 65535 Secondes 2 65535 Secondes 1 255 Sauts 0 65535 Valeurs par d faut Appliquer 36 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Surveillance SURVEILLANCE La passerelle EGX permet d afficher des donn es et tendances en temps r el ainsi que des tendances historiques Donn es en temps r el
348. pic s you wish to display and then click Apply The data logged from each device is displayed in a web page in a time trend chart format The time trend chart is preconfigured to display data from the Last Full Day Last Full Week Last Full Month or All Data Energy parameters are logged as accumulating values but are displayed as incremental values on an interval basis All other parameters are logged and displayed as the actual value recorded Figure 36 Interval Data Log Graph Interval Data Log Building North Panel PM800 Last Fut week 3 New Toprc s Data Points Select an area to zoom Press Z or double click to undo zoom Figure 37 Interval Data Log Data Points Table Error Timestamp Apparent Energy kVAh Real Energy kWh Reactive Energy kVARh 0 2008 12 03 11 45 00 4257 102 2176 477 64 073 0 2008 12 03 11 50 00 4257 785 2176 849 64 076 0 2008 12 03 11 55 00 4258 466 2177 222 64 079 0 2008 12 03 12 00 00 4259 174 2177 595 64 084 0 2008 12 03 12 05 00 4259 910 2177 967 64 089 0 2008 12 03 12 10 00 4260 638 2178 340 64 094 0 2008 12 03 12 15 00 4261 366 2178 712 64 100 41 PowerLogic Ethernet Gateway EGX300 Monitoring Getting a Data Log Log Format 42 63230 319 216B2 11 2011 Interval data logs can be retrieved using the methods in Table 15 Table 15 Interval data log retrieval methods and file formats Retrieval Method File Format Retrieved FTP Comma separated variable
349. qu dans Sous s lectionnez ou cr ez le r pertoire le r pertoire s lectionn local dans lequel le fichier doit tre enregistr puis cliquez sur Enregistrer 7 Cliquez sur le lien menant au fichier du Ouvre la bo te de dialogue de t l chargement logiciel embarqu egxxxxx upd o xxxx puis la bo te de dialogue Enregistrer sous correspond au num ro de la version puis cliquez sur Enregistrer 8 Dans la bo te de dialogue Enregistrer Enregistre le fichier UPD du logiciel embarqu Sous s lectionnez ou cr ez le r pertoire dans le r pertoire s lectionn local dans lequel le fichier doit tre enregistr puis cliquez sur Enregistrer 2011 Schneider Electric Tous droits r serv s 57 Passerelle Ethernet PowerLogic EGX300 Logiciel embarqu firmware Mise jour du logiciel embarqu firmware 58 63230 319 216B2 11 2011 Ne coupez pas l alimentation de la passerelle EGX pendant le t l chargement du logiciel embarqu Si Palimentation est coup e pendant le processus de programmation la passerelle EGX ne fonctionnera plus Le voyant LED d tat clignote rapidement pendant la programmation Lorsque le voyant se fige la programmation est achev e Lancez l Explorateur Windows tapez ftp et l adresse IP de la passerelle EGX dans la barre d adresses ex ftp 169 254 0 10 puis appuyez sur Entr e 2 Tapez le nom d utilisateur Administrator et le mot de passe correspo
350. r n 5 Seleccione uno o varios temas en la lista Temas Selecciona los temas cuyas disponibles tendencias se mostrar n NOTA Solamente estar n disponibles para el c lculo de tendencias aquellos temas comunes a todos los dispositivos seleccionados El n mero m ximo de temas cuyas tendencias se calcular n depende del n mero de dispositivos seleccionados El producto de los dispositivos y los temas seleccionados no podr ser mayor de 8 6 Haga clic en Siguiente para abrir la p gina de Abre la pagina de visualizaci n visualizaci n Tendencias en tiempo real Tendencias en tiempo real 7 Para establecer los par metros relativos a las Permite configurar los tendencias contin e con el procedimiento descrito en la par metros de las tendencias tabla que figura a continuaci n y consulte la Figura 35 Figura 34 Seleccionar dispositivos y temas Seleccionar dispositivos y temas Dispositivos disponibles Temas disponibles Building Main T Intensidad 1 Building West Panel Intensidad 2 Building East Panel Intensidad 3 Building North Panel Media de intensidad Tensi n 1 2 Tensi n 2 3 Tensi n 3 1 Tensi n media L L Tensi n 1 N Tensi n 2 N Tensi n 3 N Tensi n media L N Potencia activa tota si Potencia reactiva total kVAR Potencia aparente total kVA Demanda de intensidad 1 Demanda de intensidad 2 Demanda de intensidad 3 Frecuencia Hz O 2011 Schneider Electric Reservados todos los derec
351. r IP Adressen c ccccceeeeeeeeceeeeeeeeetaeeeeeeeeea 8 serielle Schnittstelle ca geed coves ee scecceastceescdseerehogsaazenecducsiaenoacnesees 8 Erweiterte Einstellungen der seriellen Schnittstelle 9 Verbindungen zu entfernten Ger ten 10 EGX Ger teliste 252 255 iran 12 Anschluss von Ger ten an ein EGX nennen nennen nn 12 Ger teliste einrichten 2 2 52aB2 toit 13 Ger teerkennung 2 nen anne 15 Ger teaufzeichnung su 17 Intervalldatenaufzeichnung nc nn nnnnnnns 17 Intervallaufzeichnung einrichten oooooncccccncnnnocccccncnonnancncnnnonancnncnnnnnnns 17 Aufzuzeichnende Gr en uusuesssnneeessnnnnnnnner nennen nnnnnn nn ernten 18 Ger teprotokollexport uuurnsesernnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnernnnn ern ennnnnnen nen 19 E Mail Exports rennen ne 19 FIPSEXPOI ne ee ne Re An Mae tears 21 MIT PSEXpOrTL EE See ak raie es bee Minnie ten 22 Datum und Uhrzeit nn en anna 23 Netzwerkzeitsynchronisation ee 24 SNMP Parameter esne 22 RE Matin nn 25 Modb s TCP IP Filter 0 een 25 UnterlagenlinkS 2 22 202 ne nina 26 Benutzerk nten sind 22 lH Runen 28 Webseitenzugfiff 2253252800 en iii 29 Benutzerdefinierte Webseiten hinzuf gen entfernen 30 Hinzuf gen von
352. r Protocol HTTP HTTP ist ein Netzwerkprotokoll das die bertragung von Dateien und Daten im Internet abwickelt Es stellt Webserver Funktionen ber den TCP Port 80 zur Verf gung e Hypertext Transfer Protocol Secure HTTPS HTTPS ist ein Netzwerkprotokoll das die verschl sselte bertragung von Dateien und Daten mithilfe von SSL abwickelt Es stellt sichere Webserver Funktionen ber den TCP Port 443 zur Verf gung File Transfer Protocol FTP FTP ist ein Netzwerkprotokoll mit dem Dateien ber das Internet von einem Computer zum anderen bertragen werden k nnen Sowohl der aktive als auch der passive FTP Modus werden unterst tzt haupts chlich ber TCP Port 21 Simple Network Management Protocol SNMP SNMP basiert auf dem MIB II Format und erm glicht das Speichern und bertragen von Identifikations und Diagnosedaten die f r Netzwerkverwaltungszwecke ber den UDP Port 161 benutzt werden e Address Resolution Protocol ARP ARP wird zur Konvertierung von IP Adressen in Ethernet Adressen verwendet ARP Anfragen werden vom EGX gesendet um festzustellen ob seine IP Adresse bereits benutzt wird siehe Erkennung identischer IP Adressen auf Seite 8 Simple Network Time Protocol SNTP SNTP ist ein Protokoll mit dem die Uhrzeit von Netzwerkger ten mithilfe eines NTP Servers ber UDP Port 123 synchronisiert werden kann Ethernet RJ45 Anschluss Steuerspannung WEBS ae LEDs fir Etherne
353. r Relative trending Selects graph mode NOTE Absolute redraws the graph s x axis after each sample filling it with all the data collected since the start of the trend Relative updates the graph with the latest data after each sample while the x axis stays constant to show the overall trend time selected Choose a trend time of 1 to 15 minutes This will be the Selects the amount of time of duration of the trend the trend NOTE Data samples are taken as fast as possible but may take longer depending on the communications load on the serial sub net and or remote devices 39 PowerLogic Ethernet Gateway EGX300 Monitoring Device Logging 40 63230 319 216B2 11 2011 3 Select Start Sampling to start the trending of the selected Starts trending device topics NOTE Trending may be stopped before reaching the trend time by clicking Stop Sampling If after stopping the sampling Start Sampling is pressed a new trend is started Press Data Points to view a log of all the sampled topics Displays a log of all topic values recorded during the trend time sampled during the trend NOTE After each interval the Present value of all topics along with the calculated Min Max and Average value is populated in the table below the graph Figure 35 Real Time Trending Real Time Trending 2010 02 16 05 52 57 Absolute Relative 1 Minutes _ Osta Pones NewTopi s Stat Serping 140 055250584
354. r medio del puerto UDP 123 Equipo f sico Puerto Ethernet RJ45 Alimentaci n LED de Puerto serie RS485 LED para powerLogie EX Alimentaci n Ethernet y eider y estado comunicaciones en serie a Interruptores de o puentes para polaridad resistencia de final de linea y 2 hilos 4 hilos Bot n de restablecim Puerto serie RS232 conector RJ45 O 2011 Schneider Electric Reservados todos los derechos 59 Pasarela Ethernet EGX300 de PowerLogic Ap ndice B Tipos de dispositivos admitidos AP NDICE B TIPOS DE DISPOSITIVOS ADMITIDOS 60 63230 319 216B2 11 2011 La EGX acepta los siguientes tipos de dispositivos La presente lista de dispositivos compatibles es exacta a fecha de publicaci n de este documento Para obtener actualizaciones visite el sitio web www schneider electric com Tabla 20 Tipos de dispositivos admitidos por la EGX300 Grupo de dispositivos Filtro de harm nicos activos Dispositivos Accusine Interruptores Compact NSX A Compact NSX E PowerPact A PowerPact E Circuit Monitors CM100 200 CM2000 CM3000 CM4000 10N7500 ION7550 ION7600 ION7650 Medidores digitales DM6000 DM6300 Controladores digitales de temperatura Modelo 98 Variadores ATV61 ATV71 Medidores de energia Energy Meter Enercept E5600 EM1200 EM26 96
355. r qui augmente d une unit chaque envoi d une trame Trames re ues Compteur qui augmente d une unit chaque r ception d une trame Erreurs CRC Compteur qui augmente d une unit chaque r ception d un message dont le contr le par redondance cyclique CRC ne correspond pas la valeur calcul e Indique g n ralement des probl mes de c blage Erreurs de protocole Compteur qui augmente d une unit chaque r ception d un message de format incorrect D lais d attente Compteur qui augmente d une unit chaque fois qu un message ne recoit aucune r ponse dans le temps imparti Il s agit en g n ral de la cons quence d erreurs de configuration ou d un appareil d faillant Exceptions re ues Compteur qui augmente d une unit chaque r ception d une exception Messages de lecture en partance Compteur qui augmente d une unit a chaque envoi d un message de demande de lecture Messages d criture en partance Compteur qui augmente d une unit chaque envoi d un message de demande d criture Messages de lecture en arriv e Compteur qui augmente d une unit chaque r ception d un message de demande de lecture Messages d criture en arriv e Compteur qui augmente d une unit chaque r ception d un message de demande d criture D tails Tableau d taill pr sentant des statistiques s rie et distantes par appareil Trames envoy es Compteur qui augmente d une un
356. ration Informatorisch Syslog Server IP Adresse D 0 0 0 Server UDP Port 514 1 65535 Anlage Schwere Fehler 3 3 Bericht Systemfehler Local 16 Sicherheitsfehler Auth 4 Warnungen 4 E E Konfiguration Localo 16 Benachrichtigungen 5 a E E E Informatorisch Local0 16 Informatorisch 6 E Mail Von Adresse Zu Adresse Server IP Adresse lo o a Server TCP Port 25 1 65535 SMTP Server erfordert Anmeldung Benutzername Kennwort Bericht C Systemfehler Sicherheitsfehler Konfiguration Informatorisch Systemzugangspunkt Mit dem Systemzugangspunkt k nnen andere an das Netzwerk angeschlossene Schneider Electric Gerate erkannt und Verbindungen zu ihnen hergestellt werden Diese Funktion ist so konfiguriert dass sie standardm ig ausgef hrt wird und keine weitere Konfiguration ben tigt Verwenden Sie diesen Setup Bildschirm f r die Eingabe der Gruppen IP Adresse und zugeh riger Informationen 1 Klicken Sie im Setup Men auf Das Fenster Systemzugangspunkt wird Systemzugangspunkt angezeigt 2 Aktiviert Ist dieses Kontrollk stchen aktiviert k nnen sich EGX300 Ger te mit denselben Gruppen IP Adressen untereinander erkennen Werkeinstellung Aktiviert 3 UDP Port Geben Sie die Port Nummer von 1 b
357. re d adresses ex ftp 169 254 0 10 puis appuyez sur Entr e Tapez le nom d utilisateur Administrator et Ouvre une session FTP avec la le mot de passe correspondant dans les passerelle EGX zones de texte appropri es puis cliquez sur Connexion Localisez le fichier version txt puis Affiche la version du composant image de double cliquez dessus pour l ouvrir fichier du logiciel embarqu Obtention du dernier logiciel embarqu 1 Lancez le navigateur Web Dans la barre Ouvre le site Web de PowerLogic d adresses tapez www powerlogic com et appuyez sur Entr e 2 S lectionnez votre pays puis cliquez sur Affiche le site PowerLogic de votre pays Go atteindre REMARQUE Si vous s lectionnez les tats Unis allez l tape 3 Dans le cas contraire suivez les tapes sp cifiques chaque pays pour obtenir le logiciel embarqu de la passerelle EGX 3 Cliquez sur Support gt Downloads Ouvre la page de t l chargement support gt t l chargements 4 Cliquez sur le lien EGX300 Firmware Affiche la page du logiciel embarqu de logiciel embarqu EGX300 l EGX300 5 Cliquez sur le lien menant au fichier du Ouvre la bo te de dialogue de t l chargement logiciel embarqu egxxxxx bin o xxxx puis la bo te de dialogue Enregistrer sous correspond au num ro de la version puis cliquez sur Enregistrer 6 Dans la bo te de dialogue Enregistrer Enregistre le fichier du logiciel embar
358. reil unique Les Pages d appareil unique fournissent des repr sentations graphiques et tabulaires des donn es enregistr es pour un seul appareil 1 Dans le menu Surveillance cliquez sur D veloppe l arborescence des options Journaux d appareil Journaux d appareil disponibles 2 Sous Journaux d appareil cliquez sur Developpe l arborescence pour afficher les Pages d appareil unique appareils dont les journaux de donn es peuvent tre consult s 3 Selectionnez un appareil dans la liste Affiche le journal de l appareil s lectionn Journaux d appareil 4 S lectionnez la plage de donn es Permet de s lectionner la plage de donn es afficher dans la liste d roulante tracer 5 Maintenez le bouton gauche de la souris Agrandit la partie du graphique s lectionn e enfonc et tracez une zone de s lection sur la partie du graphique agrandir 6 Pour revenir l affichage d origine L affichage r tr cit appuyez sur la touche Z du clavier ou double cliquez sur le graphique 7 Cliquez sur Acc s aux donn es pour Ouvre le tableau du Journal de donn es afficher le journal de donn es d intervalle d intervalle s lectionn s lectionn voir la Figure 37 ci dessous 8 Pour afficher d autres grandeurs cliquez Permet d afficher les grandeurs s lectionn es sur Nouvelle s grandeur s Cochez les valeurs afficher puis cliquez sur le bouton Appliquer Les donn es enregistr es pour c
359. result in property damage NOTE Provides additional information to clarify or simplify a procedure Electrical equipment should be installed operated serviced and maintained only by qualified personnel No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This Class A digital apparatus complies with Canadian ICES 003 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Contents Contents COMMONS adi sons ane i Introduction eee eee 1 Additional Resources nn rennes ile 1 Accessing the EGX Over a Network uuunsusnennnannnnannnnnnnnnnnnnnnnnnnnnnnnnannnenn 2 Logging into the EGX nid rien 2 EGX User Interface Overview uunsnnnsnnnnnnnnnnnnnannnunnnnnnnnannnnnnnnannnnnnnnennnnnnn 3 A O 5 Ethernet and
360. rm event management analysis and other functions The EGX300 supports real time data reporting from many common device types providing several device specific features Reports such as on board device and circuit summary pages as well as on board data logging and real time trending are available Figure 1 EGX300 Overview Real Time Views View device data Real Time Trends through a simple browser no software EGX300 Web Pages Data Log Trends Control Resets Pull information into E EGX100 web pages from other PowerLogic gateways Fe and Modbus TCP IP La a interfaces such as 7 nm ECC21s and PM8ECCs EGX300 ION 6200 PM800 Micrologic Sepam Documentation Go to www powerlogic com and select your country Navigate to the EGX literature Firmware Go to www powerlogic com and select your country Navigate to the EGX downloads see Getting New Firmware on page 57 for details PowerLogic Ethernet Gateway EGX300 Accessing the EGX Over a Network ACCESSING THE EGX OVER A NETWORK Logging in to the EGX 63230 319 216B2 11 2011 After you set up the EGX Ethernet parameters see the EGX installation guide you can access the EGX over an Ethernet LAN using any standard web browser 1 Launch the web browser Opens the web browser 2 Inthe Address bar type the address of Opens the Login dialog box your EGX 169 254 0 10 is the default then press Enter 3 Type yo
361. rnamen Er ffnung einer FTP Sitzung mit Administrator und das Administratorkennwort ein und dem EGX klicken Sie auf Anmelden 3 ffnen Sie den Ordner in dem die benutzerdefinierte ffnet den Ordner in dem sich die Webseite gespeichert ist klicken Sie mit der rechten benutzerdefinierte Webseite Maustaste auf die zu l schende Datei und anschlie end befindet und l scht die Datei auf L schen 4 Klicken Sie im Windows Explorer Fenster auf Schlie en von Windows Explorer Schlie en 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Setup Webseiten zur Webschnittstelle hinzuf gen 1 Klicken Sie im Setup Men auf Einblendung der Seite Webseitenzugriff Webseitenzugriff 2 Klicken Sie auf Webseiten Einblendung der Seite Webseiten hinzuf gen entfernen siehe hinzuf gen entfernen Abbildung 25 3 Wenn Sie benutzerdefinierte Webseiten zu Auswahl oder Deaktivierung einer einem EGX Ordner hinzugef gt haben benutzerdefinierten Webseite sehen Sie unter der jeweiligen Ordnerbezeichnung eine Liste mit den entsprechenden Dateinamen W hlen Sie die Webseiten aus die die Benutzer sehen sollen Deaktivieren Sie die Webseiten die Sie Ihren Benutzern nicht zeigen m chten HINWEIS Das Deaktivieren einer Webseite l scht diese nicht aus dem EGX 4 Klicken Sie auf bernehmen Hinzuf gen einer benutzerdefinierten Webseite zur EGX Webschni
362. rotocol on the serial connection is determined by the current configuration of the device in the device list Modbus TCP IP protocol is used for validation of remote devices The EGX displays the local ID stored device name and stored device type from the Device List then queries the device The device type identified by the query is displayed then compared to what was previously defined The status will then show if there is a difference found or if the previously defined configuration is valid NOTE You can edit the device name and device type and individually select which devices to store in the Device List However if logging is enabled for a device you can only modify the name 1 From the Setup menu click Device List Opens the Device List page 2 To discover locally connected devices Opens the Device Discovery page click Discover 3 Enter a Start Address and End Address Enters the discovery address range NOTE Devices previously entered in the device list with addresses Local IDs outside the discovery range will be validated 4 Click Start Discover click Stop Discover Begins to discover all connected and defined to stop the process devices NOTE Discovery only finds local serial Modbus devices connected to the EGX Remote devices must be added manually See Remote Device Connections on page 10 5 Enter a new device name in the Name text Renames the device box 6 Check the Save checkbox next to
363. rtation manuelle Courrier lectronique de test Appliquer 20 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Configuration Exportation par FTP 1 Dans la page Configuration cliquez sur Exporter le Ouvre la page Exporter le journal de l appareil journal de l appareil 2 S lectionnez FTP comme mode d acheminement Affiche les options d exportation des journaux d appareil par FTP 3 Activez l option Incr mentale Permet de s lectionner REMARQUE Si l acheminement est r gl sur les options Uniquement les nouvelles _ Horaire ou Intervalle d enregistrement la case a donn es enregistr es depuis la cocher Incr mentale est automatiquement s lectionn e derniere exportation de donn es REMARQUE Si l option Incr mentale est d sactiv e la USSIS totalit du fichier journal est envoy e par FTP chaque intervalle d fini 4 S lectionnez Horaire Quotidien Hebdomadaire Permet de s lectionner la Mensuel ou Intervalle d enregistrement fr quence d acheminement des journaux de donn es 5 Selon les options sp cifi es l tape pr c dente Sp cifie quel moment les s lectionnez l heure le jour de la semaine et ou le jour du journaux de donn es sont mois achemin s 6 Dans les zones de texte Adresse IP du serveur D finit l adresse du serveur saisissez l adresse du serveur FTP sortant de 0 0 0 0
364. rvados todos los derechos 63230 319 216B2 11 2011 DESCRIPCION GENERAL DE LA INTERFAZ DE USUARIO DE LA EGX Pasarela Ethernet EGX300 de PowerLogic Descripci n general de la interfaz de usuario de la EGX La interfaz de usuario de la EGX consta de multiples paginas web que se utilizan en la supervision y el control de dispositivos asi como el diagn stico y la configuraci n de la EGX Consulte la Tabla 1 para ver una descripci n de cada pagina web Tabla1 Paginas de la EGX Configuraci n Ethernet y TCP IP Configure los par metros de las comunicaciones Ethernet y TCP IP Configure los par metros de las comunicaciones serie Conexiones con Configure las conexiones de los dispositivos dispositivos remotos Modbus TCP IP remotos o N Lista de dispositivos de Configure identifique o verifique los dispositivos la EGX serie locales del bus de comunicaciones serie Los dispositivos remotos solamente se podr n configurar o verificar Registro de dispositivos Configure los par metros de registro de los dispositivos Exportaci n del registro de Configure las opciones de exportaci n del registro dispositivos de dispositivos ari Fecha y hora Establezca la fecha y la hora manualmente o con 23 parametros del SNTP Parametros del SNMP Configure el Protocolo simple de administraci n de redes SNMP Filtrado de Modbus TCP IP Configure las direcciones IP que podr n acceder a la EGX a trav
365. s Cuando se examinan las vistas Datos en tiempo real la EGX tiene una comprobaci n de comunicaciones automatizada que se ejecuta de forma predeterminada cada 15 minutos Para cambiar la frecuencia consulte Preferencias en la p gina 32 Esta comprobaci n verificar el buen estado de las comunicaciones de todos los dispositivos configurados en la EGX e intentar restablecer la comunicaci n con cualquier dispositivo marcado como Fuera de servicio dentro de la sesi n actual del navegador En ciertos casos es posible que no quiera esperar el tiempo necesario para comprobar las comunicaciones de forma automatizada y necesite forzar la comprobaci n en ejecuci n manual En la p gina Diagn sticos haga clic en Abre la p gina Comprobaci n de las Comprobaci n de las comunicaciones comunicaciones Haga clic en Comprobar estado del Ejecuta una comprobaci n de las comunica dispositivo ciones Los dispositivos en comunicaci n muestran Aprobado en la columna Comunica ciones y En servicio en la columna Estado Un dispositivo que no est comunicando mostrar Error en la columna Comunicaciones y Fuera de servicio en la columna Estado si ha fallado varias veces Figura 49 P gina Comprobaci n de las comunicaciones Comprobaci n de las comunicaciones Dispositivo Tipo de dispositivo Conexi n Comunicaciones Estado Building East Panel CM4000 157 198 184 114 Aprobado En servicio Building Main CM4000 Puerto
366. s Aucun bloque tous les clients Modbus TCP IP qui ne figurent pas dans la liste filtr e 1 Dans le menu Configuration cliquez sur Ouvre la page Filtrage Modbus TCP IP Filtrage Modbus TCP IP 2 S lectionnez l option Activer le filtrage Active le filtrage 3 Dans la colonne Adresse IP saisissez Saisit l adresse IP d un client Modbus TCP IP l adresse client Modbus TCP IP qui acc dera aux appareils s rie connect s la passerelle EGX 4 Dans la colonne Niveau d acc s S lectionne le niveau d acc s pour chaque s lectionnez Lecture seule ou Complet adresse IP correspondante En Lecture seule les codes de fonctions Modbus TCP IP suivants sont autoris s D cimal 1 2 3 4 7 8 11 12 17 20 24 43 100 Hexad cimal 01 02 03 04 07 08 OB OC 11 14 18 2B 64 25 Passerelle Ethernet PowerLogic EGX300 Configuration Liens vers la documentation 26 63230 319 216B2 11 2011 5 Recommencez les tapes 3 et 4 pour Ajoute d autres adresses IP filtrer ajouter d autres adresses IP 6 Cliquez sur Appliquer Enregistre la liste de filtrage des adresses Modbus TCP IP Figure 21 Page Filtrage Modbus TCP IP Filtrage Modbus TCP IP Activer le filtrage U Adresse IP Niveau d acc s La passerelle EGX prend en charge deux types de liens vers la documentation 1 Acc s aux fichiers locaux documentation stock e en interne sur la passerel
367. s entsprechende Antwort empfangen letzte Intervall nicht fehlt 100 Die Intervallzeit ist abgelaufen bevor Daten Intervall fehlt aufgezeichnet werden konnten Wenden Sie sich an die technische Unterst tzung wenn Sie bei der L sung dieser oder anderer Fehlerbedingungen Hilfe brauchen Abrufen eines Intervalldatenprotokolls Sie k nnen FTP f r das Abrufen einer Datenprotokolldatei benutzen indem mit FTP Sie ber FTP eine Verbindung mit dem EGX herstellen und die CSV Datei bertragen wie es in den nachfolgenden Schritten dargestellt wird HINWEIS Wenn Sie m chten dass das EGX die Datenprotokolldatei automatisch ber FTP bertr gt muss der Ger teprotokollexport f r FTP konfiguriert werden siehe FTP Export auf Seite 21 1 Erstellen Sie auf Ihrem Computer einen Erstellung eines Ordners zum Ablegen des Ordner z B c egx_logs EGX Datenprotokolls 2 Starten Sie Windows Explorer geben Sie Einblendung des Dialogfelds Anmelden als ftp und die IP Adresse des EGX in die Adressenleiste ein z B ftp 169 254 0 10 und dr cken Sie die Eingabetaste 3 Geben Sie in die Textfelder den Er ffnung einer FTP Sitzung mit dem EGX und Benutzernamen Administrator und das Einblendung der im EGX gespeicherten Administratorkennwort ein und klicken Sie Dateien auf Anmelden 4 Navigieren Sie zum Verzeichnis Einblendung des Datenprotokollverzeichnisses logging data im EGX im EGX 5 Kopieren Sie die Protokolldatei
368. s appareils cliquez sur REMARQUE Pour purger un s lectionner tout puis sur Appliquer journal de donn es il est imp ratif 2 Pour d s lectionner tous les appareils cliquez sur que l option Enregistrement de effacer puis sur Appliquer journaux soit d sactiv e Pour d sactiver l enregistrement s lectionnez un D sactive la fonction intervalle d enregistrement nul assurez vous que les d enregistrement options d enregistrement sont d coch es puis cliquez sur Appliquer Figure 13 Page Journaux d appareil Journaux d appareil Intervalle d enregistrement 15 B Minutes Enregistrement de journaux Purge donn es ie t e Nom d appareil Type d appareil stionr S lectionner tout Personnaliser Building Main CM4000 M grandeurs Building West Panel CM2000 M grandeurs Building East Panel CM3000 grandeurs Building North Panel PM800 O grandeurs Vous pouvez s lectionner individuellement les grandeurs consigner pour chaque appareil 1 la page Journaux d appareil cliquez sur le lien grandeurs pour Ouvre la page de l appareil en question selection des grandeurs 2 Reportez vous la Figure 14 et cochez les grandeurs que vous Permet de s lectionner souhaitez enregistrer les grandeurs Pour s lectionner toutes les grandeurs cliquez sur enregistrer s lectionner tout Pour d s lectionner toutes les grandeurs cliquez sur effacer Pour s lectio
369. s de Modbus TCP IP a Vinculos de documentaci n Configure archivos y vinculos de documentaci n de URL Cree y modifique grupos y usuarios Acceso a pagina Web Configure los derechos de acceso a las paginas web para cada grupo de usuarios Configure las preferencias de la EGX Tipos de dispositivos Configure qu tipos de dispositivos admitidos se visualizables podr n visualizar en la p gina web Lista de dispositivos de la EGX NIN N N N a o co o IN 0 wo Historial de auditoria Configure la manera en que la EGX notificara los mensajes del sistema por medio del registro de mantenimiento por correo electr nico y por el servidor Syslog remoto Punto de acceso del Habilite y configure la direcci n IP de grupo para sistema varias EGX300 permiti ndolas que se detecten entre si y vean la informaci n de las dem s Supervisi n wo x Datos en tiempo real La vista de tabla Paginas de dispositivo Unico proporciona lecturas basicas de los dispositivos seleccionados La vista de tabla Paginas de resumen de dispositivos facilita resumenes relativos a uno o mas dispositivos seleccionados La vista de la p gina Tendencias ilustra tendencias en forma de gr ficos y tablas en tiempo real correspondientes a temas comunes de varios dispositivos Registro de dispositivos P ginas de dispositivo nico proporciona registros de tendencias en forma de gr ficos y tablas que ilustran cantidades seleccion
370. s envoy es 0 Trames recues 0 Erreurs de protocole 0 Connexions actives 0 Connexions cumul es 1 Nombre maximal de connexions 1 Messages de lecture en arriv e 0 Messages d criture en arriv e o Messages de r ponse en partance 0 Trames envoy es 1946 Trames envoy es 0 Dee 5 Trames regues 1946 ues Erreurs de protocole 0 Erreurs CRC 0 E 3 Frais de Ross pe D lais d attente 0 2 D lai d attente connexion 0 D lais d attente o m Ex z 0 Exceptions re ues 0 PDP Messages de lecture en partance 1946 Messages de lecture en partance 0 er 4 Messages d criture en partance 0 Messages d criture en partance o di ne A Messages de r ponse en arriv e 1946 Messages de lecture en arriv e 0 metas Messages d criture en arriv e o Details Trames envoy es 949 Tr re ues 879 Version de logiciel embarqu 3 740 eee z 4 D lai d inactivit du syst me 26 Connexions cumul es 291 Adresse MAC 00 30 67 80 5B 61 z Nombre maximal de connexions 6 Numero de serie o Numero de modele EGX300 Version de mat rie entre Date de fabrication 2006 01 01 Envoi OK 0 Erreur de connexion o a occu E URL 0 Envoi OK 0 ERER Envoi erreur 0 Erreur de connexion 0 en 0 Erreur d authentification 0 me Erreur de r pertoire o Envoi erreur o AA Erreur g n rale 0 Envoi OK 0 Erreur de connexion 0 gt gt Re a i 0 Espace total 245889 KOctets Era oan Erreur g n rale o
371. s pasos de Identificaci n de la versi n del firmware en la p gina 56 Abre el cuadro de di logo Iniciar sesi n como Abre una sesi n de FTP con la EGX Copia el archivo de firmware en el portapapeles Copia el firmware en la EGX y luego se reinicia la EGX NOTA La luz de alimentaci n estado parpadear r pidamente mientras se est transfiriendo y programando el archivo a la EGX Una vez terminada la programaci n se restablecer la EGX El tiempo necesario para la programaci n est comprendido entre 1 5 y 2 minutos Copia el archivo de actualizaci n del disco en el portapapeles Copia el archivo en la EGX y luego se reinicia la EGX Verifica la versi n actualizada del firmware 8 Haga clic en Cerrar en la ventana del Cierra el Explorador de Windows y termina la Explorador de Windows conexi n FTP con la EGX O 2011 Schneider Electric Reservados todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Ap ndice A Protocolos Ethernet compatibles APENDICE A PROTOCOLOS La EGX acepta los siguientes protocolos Ethernet ETHERNET COMPATIBLES e Modbus TCP IP Modbus TCP IP es una combinaci n del protocolo Modbus que proporciona comunicaci n maestro esclavo entre dispositivos y TCP IP que proporciona comunicaci n a trav s de una conexi n Ethernet Se utiliza Modbus TCP IP para intercambiar datos entre la EGX y otros dispositivos compatibles con Modbus TCP IP a
372. s registrados desde el ltimo intervalo de NOTA Si el transporte se programa como ENVIO correcto Cada hora o como Intervalo de registro la casilla de verificaci n Incremental se seleccionar autom ticamente NOTA Si no se selecciona la casilla de verificaci n Incremental se enviar el archivo de registro completo por HTTP en cada intervalo programado Seleccione Cada hora Diariamente Selecciona la frecuencia con la que se Semanalmente Mensualmente o transportan los registros de datos Intervalo de registro Dependiendo de las opciones Selecciona cu ndo se transportan los registros seleccionadas en el paso anterior de datos seleccione la hora del d a el d a de la semana y o el d a del mes En los cuadros de texto Direcci n IP del Introduce la direcci n IP del servidor que servidor introduzca la direcci n del transporta los registros de datos servidor HTTP NOTA Pregunte al administrador de la red en caso de que usted no conozca la direcci n del servidor del protocolo de transferencia de hipertexto HTTP En el cuadro de texto Puerto TCP del Introduce el puerto TCP de entrega saliente servidor introduzca el puerto del Predeterminado 80 servidor HTTP NOTA Si desea exportar utilizando una capa de sockets seguros SSL introduzca el n mero de puerto TCP del servidor HTTPS que suele ser 443 En el cuadro de texto Ruta introduzca la Introduce la ruta de secuencia de comandos ru
373. sactiver pour tous les appareils 2 Pour les appareils sans mise l chelle automatique Sp cifie la plage du cadran entrez les limites Min et Max de chaque type de cadran 3 Cliquez sur Appliquer Met jour les param tres Mise l chelle automatique Figure 31 Page de configuration de plage Calibrages Min Max Nom d appareil Activer la mise l chelle automatique Courant de charge A Puissance Tension L L Tension L N s lectionner tout effacer Min Max Min Max Min Max Min Max Building Main o 100 100 100 o 100 o 100 Building West Panel 0 100 100 100 0 100 0 100 Building East Panel 0 100 100 100 0 100 0 100 Building North Panel ca _100 5 E 100 L 100 IL 0 100 0 100 Appliquer Les vues Pages r capitulatives appareils affichent des tableaux r capitulatifs concernant un appareil ou une s lection d appareils Dans le menu Surveillance cliquez sur Pages D veloppe l arborescence permettant r capitulatives appareils de s lectionner les pages de r capitulatif 2 S lectionnez la page de r capitulatif afficher Ouvre la liste de s lection d appareil 3 S lectionnez un ou plusieurs appareils dans la liste S lectionne un ou plusieurs appareils des appareils disponibles puis cliquez sur Suivant en vue de l affichage des r capitulatifs voir la Figure 32 REMARQUE Cliquez sur gt gt pour s lectionner tous les appareils disponibles Figure 3
374. sendet hat Geben Sie in das Feld Feldname den M glichkeit der bertragung von Dateien vom Namen ein unter dem der Webserver den EGX an ein vorhandenes WWW Server Script Dateinamen erwartet HINWEIS Ist das nicht erforderlich verwenden Sie den Standardwert datafile1 10 Geben Sie in das Feld Hostname den Erkennung eines bestimmten Hosts auf dem Dom nennamen des Hosts ein WWW Server wenn er mehrere Dom nen unter einer einzigen IP Adresse aufnimmt Voreinstellung ist leer 11 Geben Sie in die Textfelder Ihren Aufzeichnung Ihrer Server Anmeldedaten Benutzernamen und das Kennwort ein 12 Wenn Sie mit SSL Verschl sselung Alle Ger teprotokolle die ber HTTP exportiert exportieren m chten aktivieren Sie SSL werden verwenden dann die SSL Verschl sselung HTTPS 13 Klicken Sie auf HTTP pr fen um die von bertragung einer Testdatei an den HTTP Ihnen eingestellten HTTP Parameter zu Server und das Verzeichnis und oder berpr fen oder klicken Sie auf bernehmen der HTTP Einstellungen bernehmen HINWEIS Durch Anklicken von HTTP pr fen werden die HTTP Einstellungen f r den Protokollexport bernommen und es wird eine Testdatei bertragen Mit dem Klicken auf bernehmen werden nur die Einstellungen bernommen 22 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Datum und Uhrzeit 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic E
375. sent to the device Date Time values are reported only when the device supports them For example ifa device does not support the Min Max value for Date Time Last Reset the Min Max value will not be populated here 49 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Diagnostics 11 2011 DIAGNOSTICS To access the Diagnostics web page links click Diagnostics on the EGX menu bar Statistics This page shows accumulated readings since the EGX was last activated If power to the EGX is lost or the device is reset due to a configuration change or other event all cumulative values reset to zero 1 From the Diagnostics menu click Opens the Statistics page see Figure 47 Statistics below 2 View the data See Interpreting Statistics below 3 Click Reset Resets the EGX cumulative diagnostic data to 0 Figure 47 Statistics Page Statistics Boot Time 2010 02 15 12 20 02 Current Time 2010 02 16 06 29 14 Modus TCP Link Status 100BaseTx FD Server Frames Transmitted OK 11615 Frames Sent 0 Collisions 0 Frames Received 0 Excessive Collisions 0 Protocol Errors 0 Frames Received OK 93485 Active Connections 0 CRC Errors 0 Accumulative Connections Alignment Errors 0 Maximum Connections 4 Frames Too Long 0 Inbound Read Messages 0 Frames Too Short 0 Inbound Write Messages 0 Outbound Reply Messages 0 AAA Frames Sent 1950 a 2 Frames Received 1950 Frames Received 0 EE o CRC
376. sequenzen die sich aus der Verwendung dieser Publikation ergeben k nnen Dieses Ger t wurde getestet und erf llt die Anforderungen f r digitale Ger te der Klasse A gem Teil 15 der FCC Bestimmungen Diese Bestimmungen sollen bei der gewerblichen Nutzung des Ger ts einen angemessenen Schutz gegen sch dliche Funkst rungen sicherstellen Dieses Ger t erzeugt und nutzt Energie im Funkfrequenzspektrum und kann solche auch abstrahlen Wird es nicht der Anleitung entsprechend installiert kann es sch dliche Funkst rungen verursachen Die Verwendung dieses Ger ts in einem Wohngebiet kann sch dliche Funkst rungen verursachen In diesem Fall ist der Benutzer daf r verantwortlich die St rungen auf eigene Kosten zu beseitigen Dieses digitale Ger t der Klasse A erf llt die Anforderungen der kanadischen Norm ICES 003 Interference Causing Equipment Standard 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Inhaltsverzeichnis Inhaltsverzeichnis Inhaltsverzeichnis sise i Einf hrung AEE E E E T sougaee cee 1 Zus tzliche Ressourcen isisisi eii ici 1 Zugang zum EGX ber ein Netzwerk ss 2 Anmelden beiMEGX ui ee aa 2 EGX Benutzeroberfl che berblick 2u2u222222202020202020200000n0n0n0nnnnn0n 0 3 OU E ita an IAEA A T 5 Ethernet und TCP IP Einstellungen ooooncccnnncconocccnnncnnnnncncnn narco nennen 5 Erweiterte Ethernet Einstellungen 22us4444444H nn nennen nennen nennen 6 Erkennung identische
377. serie Aprobado En servicio Building West Panel PM6 modbus Puerto serie Aprobado En servicio Comprobar estado del dispositivo 2011 Schneider Electric Reservados todos los derechos 55 Pasarela Ethernet EGX300 de PowerLogic Mantenimiento MANTENIMIENTO FIRMWARE Identificaci n de la versi n del firmware 56 63230 319 216B2 11 2011 El registro de mantenimiento le proporciona una manera de documentar el mantenimiento realizado en la EGX los equipos conectados o el sistema del cual la EGX forma parte Cada entrada se registra con la fecha y hora en la que se hizo la entrada y el nombre del usuario que la hizo Este registro tambien enumerar autom ticamente la actividad del sistema como las funciones de activaci n o desactivaci n No tendr que a adir entradas para estos elementos Por ltimo este registro enumerar todas las actividades que se especifican para el registro de mantenimiento en la p gina de configuraci n Historial de auditor a consulte Historial de auditor a en la p gina 33 1 Enel men Mantenimiento haga clic en Abre la p gina Registro de mantenimiento Registro de mantenimiento Elimina la entrada seleccionada 2 Seleccione la casilla de verificaci n Eliminar situada junto a la entrada que desee eliminar y luego haga clic en Eliminar entradas 3 Haga clic en Eliminar registro para borrar Borra el registro de mantenimiento todas las entradas del registr
378. ses est g n r nouveau apr s chaque chantillon et comporte toutes les donn es recueillies depuis le d but de la tendance En mode Relative le graphique est mis jour avec les donn es les plus r centes apr s chaque chantillon tandis que laxe des abscisses reste constant et affiche toute la p riode de tendance s lectionn e S lectionnez la dur e de la tendance de 1 15 minutes Il s agit de la dur e de la tendance REMARQUE Les donn es sont chantillonn es aussi vite que possible mais la vitesse de transmission d pend de la charge de communication sur le sous r seau s rie et ou sur les appareils distants S lectionnez Commencer l chantillonnage pour lancer le calcul de tendance sur les grandeurs et appareils s lectionn s REMARQUE Pour arr ter le calcul de tendance avant la fin de la p riode cliquez sur Arr ter l chantillonnage Si vous arr tez l op ration puis cliquez nouveau sur Commencer l chantillonnage un nouveau calcul de tendance commence Cliquez sur Acc s aux donn es pour afficher le journal de toutes les grandeurs chantillonn es enregistr es au cours du calcul de tendance REMARQUE Apr s chaque intervalle la valeur actuelle de chaque grandeur ainsi que les valeurs Min Max et Moyenne calcul es sont ins r es dans le tableau sous le graphique Cliquez sur Nouvelle s grandeur s pour s lectionner d autres appareils et grandeurs pour le calcul de
379. set The amount of time for programming is between 1 5 and 2 minutes Locate the saved disk update file Copies the disk update file to the clipboard egxxxxx upd on your computer right click on the file name then click Copy Right click in the Windows Explorer Copies the file to the EGX and the EGX window then click Paste reboots NOTE Instead of copying and pasting the firmware file you can drag and drop the firmware file into Window Explorer To verify that the firmware version was Verifies the updated firmware version updated successfully follow the steps in Finding the Firmware Version on page 56 8 Click Close on the Windows Explorer Closes Windows Explorer and ends the FTP window connection to the EGX 58 2011 Schneider Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Appendix A Supported Ethernet Protocols APPENDIX A SUPPORTED The EGX supports the following Ethernet protocols ETHERNET PROTOCOLS Modbus TCP IP Modbus TCP IP is a combination of the Modbus protocol which provides master slave communication between devices and TCP IP which provides communications over an Ethernet connection Modbus TCP IP is used to exchange data between the EGX and other compatible Modbus TCP IP devices via TCP port 502 Hypertext Transfer Protocol HTTP HTTP is a network protocol that handles the delivery of files and data on the World Wide Web It provides
380. ss text boxes enter Enters the IP address of the server transporting the address of the HTTP server NOTE Contact your network administrator if you do not know the address of the Hyper Text Transfer Protocol HTTP server 7 Inthe Server TCP Port text box enter the Enters the outgoing delivery TCP port HTTP server port Default 80 NOTE If you want to export using a secure socket layer enter the HTTPS Server TCP Port number normally 443 8 In the Path text box enter the path to the Enters the server script path server script the web server will execute as a result of the EGX posting data to it 9 In the Field Name box enter the name Allows the EGX to push files to an existing under which the web server will expect the WWW server script file name NOTE If there is no such requirement use the default value datafile1 10 In the Host Name box enter the domain Identifies a specific host on the WWW server if name of the host it is hosting multiple domains on a single IP address Blank by default 11 Enter your user name and password in the Records your server login information text boxes 12 If you want to export using a secure socket All device logs that are exported via HTTP will layer check SSL instead use the secure socket layer HTTPS 13 Click Test to test the HTTP parameters Sends a test file to the HTTP server and you set or click Apply directory and or applies the HTTP settings
381. sserelle EGX Les appareils distants doivent tre ajout s manuellement Voir Connexions d appareils distants page 10 5 Saisissez un nouveau nom d appareil dans Renomme l appareil la zone de texte Nom 15 Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Configuration 11 2011 6 S lectionnez la case cocher Enregistrer S lectionne ou d s lectionne une entr e en regard de l appareil que vous souhaitez d appareil enregistrer ou renommer enregistrer dans la liste des appareils Cliquez sur le bouton Appliquer de la Enregistre dans la liste des appareils la page D tection des appareils configuration de tous les appareils s lectionn s Figure 12 D tection des appareils D tection des appareils 2011 11 18 11 11 31 Adresse d but Adresse fin 7 m Type d appareil Enregistrer Connexion D fini Attribu Nom Identification locale Identification distante tat F 157 Tare ECPMModelA CPM Model A PF bepm w Az za Es chec A Forsane E CM3000 Mann IT 9m MEA D tect D Port s rie gt bus 3 EZ a an D tection Arr ter la d tection Appliquer Tableau 8 Options de d tection des appareils pis PE NS EN Adresse d but fin D finit la plage d adresses Modbus utilis e 1 247 pour d tecter des appareils sur le port s rie Par d faut d but 1 fin 10 Enregistrer Permet d enregistrer l appareil s lectionn Activ ou D sactiv
382. sses IP identiques Lorsqu elle est connect e au r seau la passerelle EGX publie son adresse IP Pour viter les conflits d adresses la passerelle EGX utilise le protocole ARP Address Resolution Protocol pour v rifier si un autre appareil du r seau utilise la m me adresse IP Le Tableau 4 ci dessous d crit comment la passerelle EGX r agit en cas de d tection d une adresse IP identique Tableau 4 Sc narios de detection des adresses IP identiques Adresse IP en double d tect e Voyant DED E d alimentation tat Red marrage R tablit l adresse IP le masque de Quatre clignotements R tablissement de sous r seau et l adresse par d faut de pause l alimentation la passerelle EGX Les demandes ARP sont envoy es toutes les 15 secondes jusqu ce que l adresse IP soit disponible Lorsque l adresse est disponible la passerelle EGX l utilise Liaison Ethernet d tect e Modification manuelle La passerelle EGX conserve son des adresses adresse IP pr c dente et affiche un message qui indique que l adresse IP est d j utilis e par un autre appareil R ception d une R tablit l adresse IP le masque de Quatre clignotements demande ARP sous r seau et l adresse par d faut de pause la passerelle EGX si un appareil connect envoie quatre demandes ARP pour l adresse IP de la passerelle EGX La passerelle EGX envoie des demandes ARP toutes les 15 secondes jusqu ce que l adresse IP soit nouveau
383. sta p gina se abre desde la p gina Acceso a p gina Web 1 Inicie el Explorador de Windows escriba Abre el cuadro de di logo Iniciar sesi n ftp y la direcci n IP de la EGX por como ejemplo ftp 169 254 0 10 en el cuadro de texto Direcci n y luego pulse Intro 2 Escriba el nombre de usuario Administrator Abre una sesi n de FTP con la EGX y la contrase a de administrador en los cuadros de texto y luego haga clic en Iniciar sesi n 3 Abra una nueva ventana del Explorador de Copia el archivo en el portapapeles Windows ubique la p gina web personalizada que desee enviar a la EGX haga clic sobre ella con el bot n derecho del rat n y despu s haga clic en Copiar 4 Vuelva a la ventana del Explorador de Abre la carpeta donde se almacenar la Windows de la EGX que abri en el paso 1 p gina web en la EGX y abra la carpeta en la que vaya a copiar la p gina web por ejemplo www monitoring 5 Haga clic con el bot n derecho en el panel Copia la p gina web personalizada en la EGX derecho de la ventana del Explorador de Windows luego haga clic en Pegar NOTA En vez de copiar y pegar el archivo puede arrastrarlo y soltarlo en el Explorador de Windows 6 Haga clic en Cerrar en la ventana del Cierra el Explorador de Windows Explorador de Windows 1 Inicie el Explorador de Windows escriba Abre el cuadro de di logo Iniciar sesi n ftp y la direcci n IP de la EGX por como ejemplo ftp
384. stalar manipular y revisar el equipo el ctrico asi como realizar el mantenimiento de este Schneider Electric no asume ninguna responsabilidad de las consecuencias que se deriven de la utilizaci n de este manual 63230 319 216B2 11 2011 sustituye a 63230 319 216B1 con fecha de 08 2011 2011 Schneider Electric Reservados todos los derechos Passerelle Ethernet PowerLogic EGX300 Manuel d utilisation 63230 319 216B2 11 2011 Schneider CATEGORIES DE DANGERS ET SYMBOLES SPECIAUX VEUILLEZ NOTER DECLARATION FCC CLASSE A Lisez attentivement l ensemble de ces instructions et examinez le mat riel pour vous familiariser avec lui avant toute installation utilisation reparation ou intervention de maintenance Les messages sp ciaux qui suivent peuvent appara tre dans ce document ou sur l appareillage Ils vous avertissent de dangers potentiels ou attirent votre attention sur des renseignements pouvant claircir ou simplifier une proc dure L ajout d un de ces symboles une tiquette de s curit Danger ou Avertissement indique qu il existe un danger lectrique qui peut entra ner des blessures si les instructions ne sont pas respect es Ceci est le symbole d alerte de s curit Il sert vous avertir d un danger potentiel de blessures corporelles Respectez toutes les consignes de s curit accompagnant ce symbole pour viter tout risque potentiel de blessure ou de mort A DANGE
385. t Capacit du journal en jours pour les intervalles indiqu s grandeurs Intervalle 5 min Intervalle 10 min Intervalle 15 min 594 Ber a il L enregistrement peut amp tre active individuellement sur chaque appareil de la liste Les grandeurs consigner sont sp cifiques chaque appareil Pour afficher les journaux de donn es d intervalle voir Journaux d appareil page 40 REMARQUE Pour activer la fonction Journaux d appareil vous devez s lectionner une valeur dans la fen tre Intervalle d enregistrement Nous vous recommandons de d sactiver la fonction d enregistrement sur l appareil que vous configurez Il suffit pour cela de d cocher l option correspondante pour l appareil s lectionn voir Figure 13 page 18 17 Passerelle Ethernet PowerLogic EGX300 Configuration Grandeurs consigner 18 63230 319 216B2 11 2011 1 Dans le menu Configuration cliquez sur Journaux Ouvre la page Journaux d appareil d appareil voir Figure 13 2 Reportez vous la Figure 13 et cochez l option S lectionne les appareils dont les Enregistrement du ou des appareils dont vous donn es doivent tre enregistr es voulez enregistrer les donn es Pour s lectionner tous les appareils cliquez sur s lectionner tout puis sur Appliquer Pour d s lectionner tous les appareils cliquez sur effacer puis sur Appliquer 3 S lectionnez l intervalle d enregistrement D finit l intervalle d enregis
386. t tica de la EGX M scara de Se utiliza para introducir la direcci n de Predeterminado 255 255 0 0 subred la m scara de subred de la red Pasarela Se utiliza para introducir la direcci n IP Predeterminado 0 0 0 0 predeterminada de la pasarela router que se usa para las comunicaciones con la red de rea extendida WAN O 2011 Schneider Electric Reservados todos los derechos 5 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Configuraci n 11 2011 Configuraci n avanzada de Ethernet PRECAUCION RENDIMIENTO REDUCIDO DE LA RED Solo los trabajadores cualificados deben cambiar la configuraci n avanzada de Ethernet de la EGX Tales modificaciones deben realizarse solo despu s de leer acerca de la configuraci n avanzada de Ethernet y comprenderla El incumplimiento de estas instrucciones puede reducir el rendimiento de la red 1 Haga clic en Avanzado en la pagina Abre la pagina Configuraci n avanzada de Ethernet y TCP IP Ethernet 2 Configure los par metros avanzados de Configura los par metros avanzados de Ethernet consulte la Tabla 3 en la Ethernet p gina 7 para ver las opciones disponibles Haga clic en Predeterminados para asignar los valores predeterminados a todas las opciones 3 Haga clic en Aplicar Actualiza la configuraci n de Ethernet y TCP IP de la EGX NOTA Al aplicar los cambios a la p gina Configuraci n avanzada de Ethernet no se guardan los cambios en
387. t und serielle Kommunikations schnittstelle titi 2011 Schneider Electric Alle Rechte vorbehalten el 0 powerkoge ER ersorgungs Serielle RS485 Schnittstelle Spannungs Status LED bip Schalter zur a Konfiguration von on Vorspannung Leitungsabschluss und 2 4 Leiter Verbindung R cksetztaste Serielle RS232 Schnittstelle RJ45 Anschluss 59 PowerLogic Ethernet Gateway EGX300 Anhang B Unterst tzte Ger tetypen ANHANG B UNTERST TZTE GER TETYPEN 60 63230 319 216B2 11 2011 Das EGX unterst tzt folgende Ger tetypen Die Auflistung der unterst tzten Ger te entspricht dem aktuellen Stand zum Zeitpunkt der Ver ffentlichung dieses Dokuments F r Aktualisierungen siehe www schneider electric com Tabelle 20 Vom EGX unterst tzte Ger tetypen Ger tegruppe Oberwellenaktivfilter Leistungsschalter Ger te Accusine Compact NSX A Compact NSX E PowerPact A Circuit Monitore PowerPact E CM100 200 CM2000 CM3000 CM4000 ION7500 ION7550 ION7600 Digitalmessger te ION7650 DM6000 DM6300 Digitaler Temperaturregler Modell 98 Antriebe ATV61 ATV71 Energiemessger te Energy Meter Enercept E5600 EM1200 EM26 96 EM6400 EM6433 EM6436 EM6436DUAL EM6438 Isolations berwachungsger te ION8600 Vigilohm IM20 Vigilohm IM20 H Motorste
388. t click in the right pane of the Windows Explorer window then click Paste NOTE Instead of copying and pasting the file you can drag and drop the file into Windows Explorer Opens the Log On As dialog box Opens an FTP session with the EGX Copies the file to the clipboard Opens the folder where the web page will be stored on the EGX Copies the custom web page to the EGX 6 Click Close on the Windows Explorer Closes Windows Explorer window Launch Windows Explorer type ftp and the IP address of the EGX for example ftp 169 254 0 10 in the Address text box then press Enter 2 Type the user name Administrator and the administrator password in the text boxes then click Log On 3 Open the folder where the custom web page is located right click the file you want to delete then click Delete Opens the Log On As dialog box Opens an FTP session with the EGX Opens the folder where the custom web page is located then deletes file 4 Click Close on the Windows Explorer Closes Windows Explorer window 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Add Remove Web Pages to from the Web Interface 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup 1 From the Setup menu click Web Page Opens the Web Page Access page Access 2 Click Add Remove Web Pages see Opens the Add Remove Web Pages page Figure 25 3 If y
389. t das Datum und die Uhrzeit der Durchf hrung jeder R cksetzfunktion an Die Datums und Uhrzeit R ckstellungen werden nur angezeigt wenn das Ger t diese Funktionen unterst tzt Anzeige von Diagnosedaten zur Fehlersuche und 50 behebung bei Netzwerkproblemen Diese Seite enth lt ebenfalls spezifische Informationen ber Ihr EGX einschlie lich Seriennummer Herstellungsdatum und MAC Adresse Ger teregister lesen Damit k nnen Benutzer Registerdaten von lokalen und 5 6 entfernten Ger ten die an das EGX angeschlossen sind lesen 9 5 Kommunikationspr fung berpr fung der st rungsfreien Kommunikation mit allen im EGX konfigurierten Ger ten sowie der Eintr ge ber die durchgef hrte Wartung Wartungsprotokoll Anzeige des Datums der Uhrzeit und des Benutzers 5 der zuletzt Wartungsarbeiten am Ger t durchgef hrt hat 4 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 SETUP Ethernet und TCP IP Einstellungen 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Setup F r den Zugang zu den Links der Setup Webseiten klicken Sie auf Setup in der EGX Men leiste 1 Klicken Sie im Setup Men auf Ethernet amp Einblendung der Ethernet amp TCP IP Seite TCP IP 2 W hlen Sie Ihr Rahmenformat und das Auswahl von Rahmenformat und bertragungsmedium aus Falls Sie diese Ubertragungsmedium Informationen nicht kennen wenden
390. t insgesamt 245889 KBytes na Fohlen 7 Freie Kapazitat 243918 KBytes 99 50 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Statistik auswerten 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Diagnose Verbindungsstatus Status Zeichenkette die die Geschwindigkeit und die Duplex Einstellung darstellt die zur Kommunikation mit dem Verbindungspartner benutzt werden Rahmen ohne Fehler gesendet Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen erfolgreich gesendet wird Kollisionen Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen aufgrund der Erkennung einer Kollision neu bertragen wird Zu hohe Anzahl an Kollisionen Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen aufgrund der Erreichung des maximalen Kollisionsstatus auf der Basis des Truncated Binary Exponential Backoff Algorithmus nicht gesendet werden kann Rahmen ohne Fehler empfangen er der sich jedes Mal um eins erh ht wenn ein men erfolgreich empfangen wird CRC Fehler Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen empfangen wird dessen Pr fsumme CRC nicht mit dem berechneten Wert bereinstimmt Synchronisierfehler Z hler der sich jedes Mal um eins erh ht wenn ein Rahmen empfangen wird dessen Pr fsumme CRC nicht mit einer 8 Bit Rahmenbegrenzung endet Rahmen zu lang Z hler der sich jedes Mal um eins erh ht wenn ein Rah
391. t typisch f r Microsoft Excel 2003 4 Geben Sie im Dialogfeld Neue ffnen der Datenprotokoll Datei Webabfrage die in Schritt 2 eingegebene Adresse des Protokolls ein und klicken Sie auf Start 5 Klicken Sie auf den u ersten Pfeil um Auswahl der Daten und Einblendung des alle Daten zu markieren und klicken Sie Dialogfelds Daten importieren dann auf Importieren 6 Klicken Sie auf OK Import der Daten HINWEIS Wenn Sie jedes Mal beim ffnen der Excel Tabelle die neuesten Daten anzeigen m chten klicken Sie auf Eigenschaften im Dialogfeld Daten importieren und w hlen Sie Aktualisieren beim ffnen der Datei aus Das EGX muss f r die Sendung von Datenprotokollen an eine E Mail Adresse konfiguriert sein F r weitere Informationen hierzu siehe E Mail Export auf Seite 19 Das EGX muss so konfiguriert werden dass es Datenprotokolle an einen Webserver bertr gt F r weitere Informationen hierzu siehe HTTP Export auf Seite 22 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 berwachung bersichtsger teseiten Auf den bersichtsger teseiten befinden sich bersichten ber ein oder mehrere ausgew hlte Ger te Klicken Sie im berwachungsmen auf Erweiterung der Baumansicht f r die Ger teaufzeichnung Auswahlm glichkeiten der Ger teaufzeichnung Klicken Sie unter Ger teaufzeichnung auf bersichtsger teseit
392. ta de acceso a la secuencia de del servidor comandos del servidor que ser ejecutada por el servidor web cuando la EGX le env e datos En el cuadro de texto Nombre de campo Permite a la EGX insertar archivos a una introduzca el nombre de archivo que el secuencia de comandos existente de servidor servidor web espera recibir web NOTA Si no se requiere este dato utilice el valor predeterminado datafile 1 10 En el cuadro de texto Nombre de host Identifica un host espec fico en el servidor web introduzca el nombre de dominio del host en el caso de que aloje varios dominios en una sola direcci n IP Este cuadro est en blanco de manera predeterminada 11 Introduzca su nombre de usuario y Registra sus datos de inicio de sesi n en el contrase a en los cuadros de texto servidor dispuestos al efecto 12 Si desea exportar utilizando una capa de Todos los registros de dispositivos que se sockets seguros seleccione SSL exportan mediante HTTP lo har n a trav s de una capa de sockets seguros HTTPS 13 Haga clic en Probar HTTP para probar los Env a un archivo de prueba al servidor y valores del HTTP o haga clic en Aplicar directorio HTTP aplica los valores de HTTP o NOTA Al hacer clic en Probar HTTP se 8liza ambas acciones aplican los valores de exportaci n de registros por HTTP y se transfiere un archivo de prueba Si se hace clic en Aplicar solamente se aplicar n los valores 22 O 2011
393. tablecerlo se enviar al dispositivo la fecha y hora de la EGX Se informar de los valores de fecha hora nicamente si el dispositivo los admite Por ejemplo si el dispositivo no admite el valor de Min Max correspondiente a Fecha hora ltimo restablecimiento este valor no aparecer relleno O 2011 Schneider Electric Reservados todos los derechos 49 Pasarela Ethernet EGX300 de PowerLogic M Diagn sticos DIAGN STICOS 63230 319 216B2 11 2011 Para acceder a los vinculos de la p gina web Diagn sticos haga clic en Diagn sticos en la barra de men s de la EGX Estadisticas Esta p gina ilustra las lecturas acumuladas desde la ltima vez que se activ la EGX Si se interrumpe la alimentaci n a la EGX o si se restablece el dispositivo debido a un cambio de configuraci n u otro evento todos los valores acumulativos se ponen a cero 1 En la pagina Diagn sticos haga clic en Estadisticas 2 Observe los datos Haga clic en Restablecer 3 Figura 47 Resultado Abre la pagina Estadisticas consulte mas adelante la Figura 47 Consulte Interpretaci n de las estadisticas a continuaci n Restablece los datos de diagn stico acumulativos de la EGX a 0 P gina Estadisticas Estadisticas Hora de inicializaci n 2010 02 15 12 20 02 Hora actual 2010 02 16 06 27 04 Estado de conexi n 100BaseTx FD Servidor Tramas transmitidas satisfactoriamente 11488 Tram
394. tatus 100BaseTx FD Server Rahmen ohne Fehler gesendet 11556 Rahmen gesendet 0 Kolisionen 0 Rahmen empfangen 0 Zu hohe Anzahl an Kolisionen o Protokolifehler o Rahmen ohne Fehler empfangen 93359 Aktive Verbindungen 0 CRC Fehler o Summe der Verbindungen 1 Synchronisierfehler 0 Maximale Anzahl Verbindungen 1 Rahmen zu lang 0 Eingegangene Lesenachrichten 0 Rahmen zu kurz 0 Eingegangene Schreibnachrichten 0 Abgegangene Antwortnachrichten o i Se vir Rahmen gesendet 1950 Ratimen gosendek d Rahmen empfangen 1950 Rahmen empfangen 0 Homans Y Ea Ze t berschreitungen 0 is Verbindungszeit berschreitungen 0 Zeit berschreitungen 0 Ausnahmen empfangen 0 See Ses g Abgegangene Lesenachrichten 1950 Abgegangene Lesenachrichten 0 AOs Scirelinatiniciten 0 ETS SOME SP j Eingegangene Antwortnachrichten 1950 Eingegangene Lesenachrichten 0 cm Eingegangene Schreibnachrichten 0 ES Details AN re pa Firmwareversion 3 740 Raten anplant ae _ i Aktive Verbindungen 4 spa Summe der Verbindungen 310 MAC Adresse 00 80 67 80 58 61 Maximale Anzahl Verbindungen E Seriennummer 0 Modellnummer EGX300 Hardwareversion A Herstellungsdatum 2006 01 01 Senden OK 0 Verbindungsfehler o A Hs E URL fehler 0 crop a Sendefehler 0 Verbindungsfehler 0 z Authentifizierungafehier 0 Jgemeier Fobler u Verzeichnisfehler o Sendefehier o D SM a Allgemeiner Fehler o Senden OK 0 Verbindungsfehler 0 A ce k y Sendefehler 0 Kapazit
395. te devices can only be configured or verified Device Logging Configure device logging parameters Device Log Export Configure device logging export options Date and Time Set date and time manually or with SNTP parameters SNMP Parameters Configure Simple Network Management Protocol 25 SNMP Modbus TCP IP Filtering Configure which IP addresses can access the EGX 25 through Modbus TCP IP Configure web page access rights for each user group 29 7 a 3 a 33 Viewable Device Types Configure which supported device types are viewable in the EGX Device List web page Audit Trail Configure the ways in which the EGX will report system messages via the maintenance log e mail and remote Syslog server System Access Point Enable and configure the group IP address for multiple EGX300s allowing them to discover each other viewing each other s information Real Time Data The Single Device Pages table view provides basic readings of selected devices The Summary Device Pages table view provides summaries of one or more selected devices The Trending Page view provides real time graphic and table trending of common topics across multiple devices Device Logging The Single Device Pages provide graphic and table trending logs of user selectable quantities for selected devices The Summary Device Pages provide graphic trending logs of multiple devices with a common topic Dashboards The Dashboards provide graphic and table representations
396. tellung 1 Woche 0 0 0 0 bis 255 255 255 255 Werkeinstellung 0 0 0 0 0 0 0 0 bis 255 255 255 255 Werkeinstellung 0 0 0 0 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 SNMP Parameter Modbus TCP IP Filter 2011 Schneider Electric Alle Rechte vorbehalten PowerLogic Ethernet Gateway EGX300 Setup Das EGX unterst tzt das Protokoll SNMP mit dem der Netzwerkadministrator mit einem SNMP Manager auf ein entferntes EGX zugreifen und den Netzwerkstatus sowie die Diagnosedaten des EGX im MIB Il Format anzeigen kann 1 Klicken Sie im Setup Men auf SNMP Parameter Einblendung der SNMP Parameterseite 2 Markieren Sie SNMP aktivieren um das Simple Aktivierung von SNMP Network Management Protocol einzuschalten 3 Geben Sie den Systemverantwortlichen die Eingabe der SNMP Systembezeichnung den Systemstandort den Systeminformationen und der Community Namen mit schreibgesch tztem Zugriff Community Zugriffsnamen und den Community Namen mit Lese und Schreibzugriff ein 4 Klicken Sie auf bernehmen Speicherung der SNMP Einstellungen Abbildung 20 Seite SNMP Parameter SNMP Parameter SNMP aktivieren M Systemverantwortlicher Admin Systembezeichnung John Smith Systemstandort Office 1 Communityname mit Nur Lese Zugriff public Communityname mit Lese und Schreibzugriff private Mit dieser Funktion kann der Administrator die Zuga
397. the beginning and end of the Daylight begin and end Daylight Savings Time Savings Time adjustment 6 Click Apply Saves the Date and Time settings Figure 18 Date and Time Page Date and Time Enable Network Time Synchronization M 2011 y November y 17 fis y 17 7 02 y Time Zone Offset Jurc 06 00 y Enable Automatic Daylight Savings Time Adjustment M Daylight Savings Time Begins second y Sunday y of March y at 02 00 y Daylight Savings Time Ends First y sunday y of November at 02 00 y Apply 23 PowerLogic Ethernet Gateway EGX300 Setup Network Time Synchronization 24 63230 319 216B2 11 2011 Enabling network time synchronization allows the time and date of the EGX system clock to be set by a Network Time Protocol NTP server NOTE Ifthe NTP server is not located on the same Ethernet network segment as the EGX be sure the EGX Default Gateway is properly configured Select the Enable Network Time Synchro Reveals the SNTP Parameters section and the nization check box in the Date and Time last successful time synchronization page Configure the time zone offset poll Sets up the SNTP parameters interval and the primary and secondary NTP server IP addresses see Table 10 3 Click Apply Saves the SNTP settings Figure 19 Enable Network Time Synchronization Date and Time Enable Network Time Synchronization M Date Ti
398. the page 26 for setting URL access Documentation page Allows users to send a dashboard E mail recipient must have an EGX URL in the body of an E mail user account to view a dashboard See User Accounts on page 28 System Access Point The EGX can discover and provide links to EGX300s and other Schneider Electric devices that are connected to the network This provides an access point to a system of networked Schneider Electric devices The System Access Point page lists each of the discovered Schneider Electric devices as a hyperlink As you hover over a device in the list additional details about the device displays to the left of the listing Click any device to go to the log in page for that device Figure 44 System Access Point Page Showing Device Detail Platform cogo gm Access Point MAC Address 00 80 67 80 5A A5 r IP Address Firmware Version 3942 157 198 184 41 Serial Number 0 157 198 184 43 Hold Time 58 fh 157 198 184 45 157 198 184 54 157 198 184 79 157 198 184 685 157 198 184 87 gt 0 91 157 198 184 91 PowerLogic EGX300 157 198 184 177 Refresh Clear 48 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 DOCUMENTATION CONTROL 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Documentation The Documentation page allows you to access information that has been stored as files
399. thernet Gateway EGX300 Setup Abbildung 17 Seite Ger teprotokollexport HTTP Ger teprotokollexport O Deaktiviert O E Mail OFTP O HTTP Inkrementell O Aufzeichnungsintervall Ost ndlich OT glich OW chentlich Monatlich Tageszeit 00 00 Tag der Woche tag Tag des Monats 1 Server IP Adresse 0 0 o D Server TCP Port 80 Pfad Feldname datafile1 Hostname optionaler virtueller Hostname Benutzername user Kennwort mm SSL Manueller Export Test E Mail FTP pr fen HTTP pr fen Mit der Seite Datum und Uhrzeit k nnen Sie das Datum und die Uhrzeit f r das EGX einstellen 1 Klicken Sie im Setup Men auf Datum und Einblendung der Seite Datum und Uhrzeit Uhrzeit 2 Konfigurieren Sie Jahr Monat Tag Einstellung des Datums und der Uhrzeit des Stunden Minuten und Sekunden Systems 3 W hlen Sie den Zeitzonenausgleich Einstellung der Uhr auf die gew hlte Zeitzone 4 Damit sich die Uhr automatisch auf die Einstellung der Uhr auf automatische Sommerzeit umstellt aktivieren Sie das Umstellung auf Sommerzeit Kontrollk stchen Automatische Sommerzeiteinstellung aktivieren 5 Geben Sie den Tag im Monat den Wochentag den Monat und die Stunde f r Sommerzeitumstellung Beginn und Ende der Sommerzeit ein 6 Klicken Sie auf bernehmen Speicherung der Datums und Uhrz
400. tima exportaci n de datos realizada correctamente Selecciona la frecuencia con la que se env an los registros de datos 19 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Configuraci n 11 2011 20 Dependiendo de las opciones seleccionadas en el paso anterior seleccione la hora del dia el dia de la semana ylo el dia del mes En el cuadro de texto Desde direcci n escriba la direcci n de correo electr nico de la persona que administra el dispositivo NOTA Se necesita una direcci n de correo electr nico del remitente porque la mayoria de los servidores SMTP asi lo requieren En los cuadros de texto A direcciones escriba las direcciones de correo electr nico cinco como m ximo de las personas que van a recibir los registros de datos una direcci n por cada cuadro de texto En los cuadros de texto Direcci n IP del servidor introduzca la direcci n del servidor de correo saliente 0 0 0 0 a 255 255 255 255 NOTA Pregunte al administrador de la red en caso de que usted no conozca la direcci n del servidor de protocolo sencillo de transferencia de correo SMTP En el cuadro de texto Puerto TCP del servidor introduzca el puerto de entrega del servidor de correo saliente Si el servidor SMTP requiere informaci n de inicio de sesi n habilite la casilla de verificaci n El servidor SMTP requiere iniciar sesi n NOTA La EGX es compatible con autenticaci n de acceso Plain Log
401. tionsanwendung speichern Ma nahme Ergebnis Klicken Sie in der Instrumententafel mit Anzeige der Datenpunkte f r die ausgew hlte den gew nschten Daten auf Datenpunkte Instrumententafel Abbildung 43 Abrufen von Instrumententafeldaten mit der Schaltfl che Datenpunkte Dr cken Sie STRG A und dann STRG C Auswahl aller Daten und Kopieren der Daten in die Zwischenablage ffnen Sie Excel und dr cken Sie dann Einf gen der Daten in eine Excel Tabelle STRG V Speichern einer Instrumententafel Damit nicht jeder Zugriff auf eine Instrumententafel ber das Hauptmen erfolgen muss verwenden Sie f r das Speichern einer Instrumententafel eine der in Tabelle 18 beschriebenen Methoden Tabelle 18 Speichern einer Instrumententafel Beschreibung Einstellung Browser Lesezeichen Damit k nnen Benutzer ber den Befolgen Sie die Anweisungen Computer auf die gespeicherte zum Erstellen eines Systemzugangspunkt 48 Instrumententafel zugreifen auf dem das Lesezeichen erstellt wurde Lesezeichens in Ihrem bevorzugten Browser Unterlagenlink Damit k nnen EGX Benutzer ber die Unterlagenseite auf eine gespeicherte Instrumententafel zugreifen F r das Erstellen eines URL Zugriffs siehe Unterlagenlinks auf Seite 26 Damit k nnen Benutzer eine Instrumententafel URL im Hauptteil einer E Mail versenden Der E Mail Empf nger muss zum Anzeigen einer Instrumententafel ein EG
402. todos los derechos 63230 319 216B2 Pasarela Ethernet EGX300 de PowerLogic 11 2011 Supervision SUPERVISION La EGX proporciona pantallas en las que muestra datos y tendencias en tiempo real ademas de tendencias hist ricas de registros de datos Datos en tiempo real Las paginas Datos en tiempo real proporcionan lecturas basicas de dispositivos seleccionados en tiempo real asi como resumenes de dispositivos Paginas de dispositivo unico Para ver una tabla de datos en tiempo real vaya al men Supervisi n y seleccione un dispositivo bajo Datos en tiempo real gt Paginas de dispositivo Unico Configuraci n de lecturas basicas En la parte superior de la pantalla seleccione Selecciona las cantidades que se Intensidad Potencia Tensi n L L o Tensi n L N mostrar n en la pantalla gr fica de para que aparezcan en la pantalla gr fica de indicadores anal gicos indicadores anal gicos NOTA Los indicadores anal gicos no est n disponibles en todos los tipos de dispositivos De manera predeterminada los indicadores Controla el rango de visualizaci n de ajustar n autom ticamente el rango de los indicadores anal gicos visualizaci n Si desea un rango fijo seleccione Rango Las instrucciones para configurar el rango de los indicadores anal gicos se encuentran en la tabla siguiente Figura 30 P gina Lecturas b sicas Lecturas b sicas Building Main CM4000 2010 02 15 12 42 18 326 13 A Activa kw
403. trav s del puerto TCP 502 e Protocolo de transferencia de hipertexto HTTP HTTP es un protocolo de red que realiza los envios de archivos y datos en Internet Proporciona funcionalidad de servidor web a trav s del puerto TCP 80 e Protocolo de transferencia de hipertexto seguro HTTPS HTTPS es un protocolo de red que realiza los envios cifrados de archivos y datos en Internet mediante SSL Proporciona funcionalidad de servidor web a trav s del puerto TCP 443 e Protocolo de transferencia de archivos FTP FTP es un protocolo de redes que ofrece la capacidad de transferir archivos por Internet de un ordenador a otro Se admiten los modos FTP activo y pasivo principalmente a trav s del puerto TCP 21 e Protocolo simple de administraci n de redes SNMP SNMP se basa en el formato MIB2 y proporciona la capacidad de almacenar y enviar informaci n de identificaci n y diagn stico utilizada en la red por razones de administraci n por medio del puerto UDP 161 e Protocolo de resoluci n de direcci n ARP ARP se utiliza para convertir las direcciones IP en direcciones Ethernet Las solicitudes de ARP se env an a trav s de la EGX para determinar si su direcci n es el duplicado de una direcci n IP consulte Detecci n de direcciones IP duplicadas en la p gina 8 e Protocolo simple de hora de la red SNTP SNTP es un protocolo que se usa para sincronizar los relojes de los dispositivos en red utilizando un servidor NTP po
404. tre affiche les donn es voir la Figure 36 cliquez sur bouton enregistr es Acc s aux donn es 2 Appuyez sur CTRL A puis sur CTRL C S lectionne toutes les donn es puis les copie dans le Presse papiers 3 Ouvrez Excel et appuyez sur CTRL V Colle les donn es dans une feuille de calcul Excel 1 Lancez votre navigateur Web Ouvre le navigateur Web 2 V rifiez que le journal est disponible en Ouvre la page des journaux de donn es tapant l adresse IP de la passerelle EGX300 suivie de stream devlog_data html device x o x correspond l identification locale de l appareil 3 Lancez Excel et cliquez sur Donn es gt Ouvre la boite de dialogue Nouvelle requ te Donn es externes gt Nouvelle requ te sur le Web de Microsoft Excel sur le Web REMARQUE Le chemin d acc s indiqu correspond a Microsoft Excel 2003 4 Dans la boite de dialogue Nouvelle Ouvre le journal des donn es requ te sur le Web tapez l adresse du journal que vous avez saisie l tape 2 puis validez 5 Cliquez sur la fl che la plus a l ext rieur S lectionne les donn es puis ouvre la boite de pour s lectionner toutes les donn es puis dialogue Importer des donn es cliquez sur le bouton Importer 6 Cliquez sur OK Importe les donn es REMARQUE Si vous voulez afficher les donn es les plus r centes chaque fois que vous ouvrez la feuille de calcul cliquez sur le bouton Propri t s dans la boite de dialogue
405. trement pour les appareils s lectionn s 4 Cliquez sur Appliquer Met jour les param tres d enregistrement des journaux d appareil de la passerelle EGX Pour personnaliser le contenu enregistr activez S lectionne les grandeurs d appareils l enregistrement puis proc dez comme suit enregistrer puis revient la page S lectionnez un intervalle d enregistrement non nul puis d cochez l option d enregistrement pour REMARQUE Si vous modifiez l appareil en question les grandeurs par d faut Journaux d appareil principale Cliquez sur grandeurs sous Personnaliser pour enregistr es pour un appareil un l appareil que vous souhaitez configurer de ire des ReponezousalaFawe 14 IE appareil La modification des Pour s lectionner toutes les grandeurs cliquez grandeurs d un journal d appareil sur s lectionner tout puis cliquez sur d j activ a pour cons quence Appliquer d effacer toutes les donn es Pour d s lectionner toutes les grandeurs cliquez pr c demment enregistr es pour sur effacer puis cliquez sur Appliquer cet appareil Si n cessaire il Pour s lectionner les grandeurs par d faut convient de r cup rer les A a donn es de l EGX avant les cliquez sur Valeurs par d faut en bas de l cran modifications Pour supprimer un journal de donn es cochez l option Selectionne les journaux de donn es Purge donn es du ou des journaux en question purger 1 Pour s lectionner tous le
406. tric Tous droits r serv s 63230 319 216B2 Passerelle Ethernet PowerLogic EGX300 11 2011 Annexe B Types d appareil pris en charge Tableau 20 EGX300 Types d appareil pris en charge Groupe d appareils Appareils Modules d interface intelligents SIMIO SIM10M SIM6BZ Dispositifs de d marrage en douceur ATS48 MVSS RVSS Capteurs de temp rature d humidit ZED THL M ou de lumi re Unit s de contr le Micrologic A Micrologic E Micrologic H Micrologic P Autre Acti9 Multicontro O 2011 Schneider Electric Tous droits r serv s 61 Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Annexe B Types d appareil pris en charge 11 2011 62 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 Index A acc s la passerelle EGX via un r seau 2 adresse IP detection des adresses identiques 8 affichage des donn es et tendances en temps r el 37 appareils Modbus d tection 15 ARP Address Resolution Protocol 8 B bouton Acc s aux donn es journal de donn es d intervalle 44 C calcul de tendance 39 certificat d authentification num ro de port HTTPS 7 codes d erreur journal de donn es 43 commande 49 comptes utilisateurs configuration 28 configuration EGX 5 liste des appareils 13 ports s rie 8 synchronisation de l heure r seau 24 connexion l EGX 2 connexions d appareils 12 d appareils distants 10 courrier
407. tric conectados a la red y vincularse a estos Esta funci n est configurada para su ejecuci n de manera predeterminada por lo que no es necesario configurar ning n par metro adicional Esta pantalla de configuraci n le permitir introducir la direcci n IP del grupo y su informaci n asociada Resultado 1 Enel men Configuraci n haga clic Abre la ventana Punto de acceso del sistema en Punto de acceso del sistema 2 Activado Cuando se marca esta casilla las EGX300 con la misma direcci n IP del grupo podr n detectarse entre s Predeterminado Activado 3 Puerto UDP Escriba el n mero de puerto de 1 a 65535 correspondiente al puerto UDP que utiliza la detecci n de la funci n Punto de acceso del sistema Predeterminado 59 4 Direcci n IP del grupo Escriba la direcci n IP del grupo que admitir direcciones de unidifusi n o multidifusi n Predeterminado 224 0 1 2 5 Intervalo de introducci n Periodo de tiempo transcurrido entre mensajes de bienvenida emitidos por esta EGX300 con que se anuncia su presencia a otros dispositivos de punto de acceso del sistema de Schneider Electric que se encuentren en red De 1 a 65535 segundos Predeterminado 300 segundos O 2011 Schneider Electric Reservados todos los derechos 35 Pasarela Ethernet EGX300 de PowerLogic 63230 319 216B2 Configuraci n 11 2011 6 Tiempo de espera Periodo de tiempo durante el cual los mensajes de bienvenida que emite esta EG
408. tsynchronisation aktivieren M Datum Uhrzeit Zeitzonenparameter Zeitzonenausgleich UTC 06 00 x Automatische Sommerzeiteinstellung aktivieren Sommerzeit beginnt von um Sommerzeit endet von um SNTP Parameter Abrufintervall 1 Stunde M IP Adresse des prim ren NTP Servers 0 D 0 D IP Adresse des sekund ren NTP Servers 0 0 0 0 Letzte erfolgreiche Zeitsynchronisierung Datum und Uhrzeit Server IP Adresse Tabelle 10 Einstellung der SNTP Parameter Zeitzonenausgleich Automatische Sommerzeitein stellung aktivieren Abrufintervall IP Adresse des primaren NTP Servers IP Adresse des sekundaren NTP Servers Zeiteinstellung auf der Basis des gew hlten Werts der Coordinated Universal Time UTC Damit k nnen Sie den Beginn und das Ende der Sommerzeit festlegen Steuerung wie oft das EGX den NTP Server wegen der richtigen Uhrzeit kontaktiert Die IP Adresse des prim ren NTP Servers den das EGX nach der richtigen Uhrzeit fragt Die IP Adresse des sekund ren NTP Servers den das EGX nach der richtigen Uhrzeit fragt UTC 12 00 bis UTC 13 00 Werkeinstellung UTC GMT Erster bis F nfter oder letzter Sonntag bis Samstag Januar bis Dezember 0 00 bis 23 00 Werkeinstellung Beginn am zweiten Sonntag im M rz um 2 00 Uhr Ende am zweiten Sonntag im November um 2 00 Uhr 1 Stunde bis 1 Woche Werkeins
409. ttstelle oder Entfernen einer benutzerdefinierten Webseite von der EGX Webschnittstelle Abbildung 25 Seite Webseiten hinzuf gen entfernen Webseiten hinzufuegen entfernen berwachung Steuerung Wartung device shtml 2011 Schneider Electric Alle Rechte vorbehalten 31 PowerLogic Ethernet Gateway EGX300 Setup Pr ferenzen 32 63230 319 216B2 11 2011 Mit dieser Option kann jedes EGX einzeln angepasst werden 1 Klicken Sie im Setup Men auf Einblendung der Seite Pr ferenzen Pr ferenzen 2 Geben Sie den Ger tenamen die voreingestellte Startseite die Echtzeit Abtastrate und die H ufigkeit der Kommunikationspr fung ein 3 Klicken Sie auf bernehmen Aktualisierung der EGX Pr ferenzeinstellungen Abbildung 26 Seite Pr ferenzen Einstellung der Pr ferenzen Pr ferenzen Echtzeit Abtastrate 5 Ger tename Voreingestellte Startseite Startseite sal M Sekunden H ufigkeit der Kommunikationspr fung Deaktiviert y Minuten Tabelle 13 Pr ferenzeinstellungen Ger tename Voreingestellte Startseite Echtzeit Abtastrate H ufigkeit der Kommu nikationspr fung Hier k nnen Sie einen benutzerdefinierten Namen f r das EGX und dazugeh rige Ger te eingeben Dieser Name wird im Banner der Webschnittstelle benutzt M glichkeit der Auswahl einer voreingestellten Startseite Steu
410. tzt A Schreibgesch tzt v v v LM EJE Keine Keine Keine Schreibgesch tzt v Schreibgesch tzt v Schreibgesch tzt v Keine Schreibgesch tzt v Schreibgesch tzt M Schreibgesch tzt v Keine v Schreibgesch tzt v Schreibgesch tzt Schreibgesch tzt Schreibgeschitzt Vollst ndig Schreibgesch t zt 74313 Rd Vollst ndig Schreibgesch tzt M Schreibgesch tzt M Schreibgesch tzt y Schreibgesch tzt se El Schreibgesch tzt Schreibgesch tzt v Schreibgeschitzt Schreibgesch tzt Schreibgesch tzt Vollst ndig Schreibgesch tzt v v v v v Keine Keine Keine Keine Schreibgesch tzt Keine EL E Schreibgesch tzt v Schreibgesch tzt M Schreibgesch tzt v Keine lt Schreibgeschitzt v Schreibgesch tzt M Schreibgesch tzt v Keine Schreibgesch tzt v Schreibgesch tzt M Schreibgesch tzt M v Keine Schreibgesch tzt i Schreibgesch tzt Schreibgesch tzt Schreibgesch tzt v v v Schreibgesch tzt M Schreibgesch tzt x Schreibgesch tzt x Schreibgesch tzt y Schreibgesch tzt Schreibgesch tzt Schreibgesch tzt Schreibgesch tzt v v T v v Keine Keine Keine REE ERIE We
411. uerung TeSys T Multi Circuit Monitore MCM BCPM Modell A BCPM Modell B BCPM Modell C BCM Uberlastrelais SSOLR MCM MotorLogic Plus MotorLogic Plus II Leistungsfaktorregler Varlogic Power Meter PM9c PM200 PM300 PM500 PM600 PM700 PM800 PM1000 PM5000 ION6200 Standard und Mega ION7300 Schutzrelais Sepam 2000 Sepam Serie 10 Sepam Serie 20 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Anhang B Unterst tzte Ger tetypen Tabelle 20 Vom EGX unterst tzte Ger tetypen Ger tegruppe Ger te Sepam Serie 40 Sepam Serie 80 Intelligente Schnittstellenmodule SIM10Z SIM10M SIM6BZ Sanftanlasser ATS48 MVSS RVSS Temperatur Feuchte und ZED THL M Lichtsensoren Ausl sesysteme Micrologic A Micrologic E Micrologic H Micrologic P Sonstiges Acti9 Multicontrol 2011 Schneider Electric Alle Rechte vorbehalten 61 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Anhang B Unterst tzte Ger tetypen 11 2011 62 2011 Schneider Electric Alle Rechte vorbehalten 63230 319 216B2 11 2011 Index A Analogmessger tbereich 38 Anmelden beim EGX 2 Anschluss von Ger ten 12 Anzeigbare Ger tetypen 33 Anzeige von Echtzeitdaten und Trendkurven 37 ARP Address Resolution Protocol 8 Aufzeichnung 17 40 Datenf
412. ugmente d une unit chaque ion d une trame sup rieure la taille maximale autoris e d finie dans les normes trames sup rieures 1518 octets Longueur de trame insuffisante Compteur qui augmente d une unit chaque r ception d une trame inf rieure la taille minimale autoris e d finie dans les normes trames inf rieures 64 octets Modbus TCP IP Serveur Trames envoy es Compteur qui augmente d une unit a chaque envoi d une trame Compteur qui augmente d une unit chaque r ception d une trame Compteur qui augmente d une unit chaque r ception d un message de format incorrect Valeur qui indique le nombre de connexions actives lors de la mise jour de la page de diagnostics Prise en charge de 64 connexions maximum Cliquez sur Connexions actives pour ouvrir une nouvelle fen tre qui affiche la liste de toutes les connexions client actives Compteur qui augmente d une unit chaque connexion tablie avec la passerelle EGX Valeur qui indique le nombre maximal de connexions qui taient actives un instant donn Trames re ues Erreurs de protocole Connexions actives Connexions cumul es Nombre maximal de connexions Messages de lecture en arriv e Compteur qui augmente d une unit chaque r ception d un message de demande de lecture Messages d criture en arriv e Compteur qui augmente d une unit chaque r ception d un message de demande d
413. ulatives appareils Calcul de tendance J umaux d appareil Ratios name as Pages d appareil unique 244444n0s2nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnenn Obtention d un journal de donn es Format des journaux ns nssrrnn rsrsr tn rn nnrnnnn nenene 2011 Schneider Electric Tous droits r serv s i Passerelle Ethernet PowerLogic EGX300 63230 319 216B2 Table des mati res 11 2011 Codes d erreur des journaux de donn es 43 Obtention d un journal de donn es d intervalle via FTP 43 Obtention d un journal de donn es d intervalle par le biais du bouton Acc s aux donn es ernennen nennen nenn 44 Obtention d un journal de donn es d intervalle par le biais d une requ te Web Microsoft 44 Obtention d un journal de donn es d intervalle par courrier lectronique rss ass is Rens er ra enter bare dan 44 Obtention d un journal de donn es d intervalle par HTTP 44 Pages r capitulatives appareils Tableaux de bord Affichage d un tableau de bord Acc s aux donn es de tableau de bord par le biais du bouton ACCES aux dONM ES circa es nenne Enregistrement d un tableau de bord Point d acc s syst me su Documentation sasapian aasien aiaa ENEN aD 49 Commande sisi ii ii tes 49 DIAGN KoX 1 0 VARRCRELPRSERRESETPEFRRIEREFCRHRHERCPEECREERFUERFTEFFRREFFORERERFIEEREEFORFENRNEERREELTFEFRGET 50 Statistiques uns
414. und f gen Kopieren des Datenprotokolls in Ihren Ordner Sie diese dann in den im Schritt 1 erstellten Ordner ein 2011 Schneider Electric Alle Rechte vorbehalten 43 PowerLogic Ethernet Gateway EGX300 berwachung Abrufen eines Intervalldatenprotokolls mit der Schaltfl che Datenpunkte Abrufen eines Intervalldatenprotokolls mit Microsoft WebQuery Abrufen eines Intervalldatenprotokolls ber E Mail Abrufen eines Intervalldatenprotokolls ber HTTP 44 63230 319 216B2 11 2011 Klicken Sie auf der Webseite Einblendung eines neues Fensters mit Anzeige Ger teaufzeichnung siehe der aufgezeichneten Daten Abbildung 36 auf die Schaltfl che Datenpunkte 2 F hren Sie die Tastenkombinationen Auswahl aller Daten und Kopieren der Daten in STRG A und danach STRG C aus die Zwischenablage 3 ffnen Sie Excel und f hren Sie dann die Einf gen der Daten in eine Excel Tabelle Tastenkombination STRG V aus Ma nahme Ergebnis 1 Starten Sie den Webbrowser Einblendung des Webbrowsers 2 berpr fen Sie ob die Protokolldatei Einblendung der Datenprotokoll Seite verf gbar ist Geben Sie dazu die IP Adresse des EGX300 gefolgt von stream devlog_data html device x ein wobei x f r die lokale ID des Ger ts steht 3 Starten Sie Excel und klicken Sie auf Einblendung des Excel Dialogfeldes Daten gt Externe Daten importieren gt Neue Webabfrage Neue Webabfrage HINWEIS Der dargestellte Pfad is
415. ur qui augmente d une unit chaque fois que le serveur HTTP ne parvient pas authentifier les identifiants Utilisateur Mot de passe Envoi erreur Compteur qui augmente d une unit chaque chec de transfert d un fichier vers le serveur HTTP Erreur g n rale Compteur qui augmente d une unit chaque fois qu un fichier ne peut tre envoy parce que la passerelle EGX ne parvient pas mettre la transaction Client FTP Envoi OK Compteur qui augmente d une unit apr s chaque transfert r ussi vers un serveur FTP Erreur de connexion Compteur qui augmente d une unit chaque fois que la passerelle EGX ne parvient pas tablir la connexion avec le serveur FTP Erreur d authentification Compteur qui augmente d une unit chaque fois que le serveur FTP ne parvient pas authentifier les identifiants Utilisateur Mot de passe Erreur de r pertoire Compteur qui augmente d une unit chaque fois que le serveur FTP ne parvient pas localiser le r pertoire demand Envoi erreur Compteur qui augmente d une unit chaque chec de transfert d un fichier vers le serveur FTP Erreur g n rale Compteur qui augmente d une unit chaque fois qu un fichier ne peut tre envoy parce que la passerelle EGX ne parvient pas mettre la transaction Client SMTP Envoi OK Compteur qui augmente d une unit chaque fois qu un courrier lectronique est envoy sans probl me au serveur SMTP
416. ur user name Administrator is the Enters the user name and password then default and password Gateway is the opens the EGX home page default into the text boxes then click OK NOTE The user name and password are case sensitive 4 Click the appropriate item from the Menu Opens the selected Menu item bar Figure 2 The EGX Home Page Schneider PowerLogic EGX300 Electric N Documentation va P contro diagnostics Maintenance TU setup Firmware verson 3800 Copyright 2005 2010 Schneider Electne All Rights Reserved User Administrator We recommend logging out whenever you do not need access to the EGX To log out of the EGX session click Log Out or just close your browser 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 EGX USER INTERFACE OVERVIEW 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 EGX User Interface Overview The EGX user interface consists of multiple web pages used for device monitoring and control and EGX diagnostics and setup See Table 1 for a description of each web page Table 1 EGX Pages Ethernet amp TCP IP Configure Ethernet and TCP IP communication settings Serial Port Configure serial communication parameters 8 Remote Device Connections Configure remote Modbus TCP IP device connections 12 EGX Device List Configure identify or verify local serial devices on the daisy chain Remo
417. urchlaufen kann Werkeinstellung 60 Hops TCP Keep Alive Ein Timer der feststellt wenn ein ber eine 0 bis 65 000 Sekunden unbelegte Verbindung angeschlossenes Ger t Werkeinstellung aufgrund von Ereignissen wie Neustart oder 30 Sekunden Ausschalten nicht mehr verf gbar ist Der Wert 0 deaktiviert diese Einstellung BootP Legt fest wie lange das EGX auf die Zuweisung 0 bis 60 Sekunden Zeit berschreitung seiner IP Adresse durch einen BootP Server Werkeinstellung wartet Wenn nach Ablauf der Zeit keine IP 15 Sekunden Adresse zugewiesen wurde wird die voreingestellte IP Adresse verwendet Legt fest wie lange Eintr ge in der ARP Tabelle 0 bis 65 000 Minuten Address Resolution Protocol verbleiben Werkeinstellung 15 Minuten FTP Server Steuert die Aktivierung der Initialisierung des Deaktiviert oder FTP Servers beim Start Aktiviert FTP Verbindungs Ein Timer der eine FTP Verbindung nach einer 30 bis 900 Sekunden leerlaufzeit festgelegten Leerlaufzeit schlie t Werkeinstellung 120 Sekunden HTTP Verbindungs Ein Timer der eine HTTP Verbindung nach einer 0 bis 65 000 Sekunden leerlaufzeit festgelegten Leerlaufzeit schlie t Werkeinstellung 4 Sekunden HTTP Port Nr Der f r HTTP Meldungen verwendete TCP Port 0 bis 65 000 Die folgenden Portnummern sind f r andere Werkeinstellung 80 Netzwerkprotokolle reserviert und k nnen nicht 0 HTTP Port verwendet werden 20 und 21 FTP und 502 deaktiviert Modbus TCP
418. using FTP 1 From the Setup menu click Opens the Documentation Links page Documentation Links 2 For File Access Check Enabled for the Checks which files and URLs appear on the File Name link s you want to enable Documentation page For URL Access Check Enabled for the URL link s you want to enable 3 Check New Window if you want the Checks which files and URLs open in a new selected files and URLs to open in a new window when clicked window when clicked 4 Name the documentation link title in the Sets the documentation link title that will Link Text text box appear on the Documentation page 5 Click Apply Updates the EGX Documentation Link settings 26 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Setup Figure 22 Documentation Links Page Documentation Links EGX300 S Top Cap Image JEGX300 Enclosure Image EGX300 Square D Top Cap Image IEGX100 Install Guide http www powerlogic com PowerLogic Web Site NOTE For information on accessing the loaded documentation see Documentation on page 49 27 PowerLogic Ethernet Gateway EGX300 Setup User Accounts 28 63230 319 216B2 11 2011 EGX users are assigned user names and passwords Each user belongs to a group and each group has access rights to the E
419. utom tico del horario de verano 5 Introduzca n mero d a mes y hora de Establece el comienzo y fin del ajuste del comienzo y fin del horario de verano horario de verano 6 Haga clic en Aplicar Guarda la configuraci n de Fecha y hora Figura 18 P gina Fecha y hora Fecha y hora Activar sincronizaci n horaria de red 2008 v Enero v 26 Desviaci n de zona horaria urc 06 00 y Habilitar ajuste autom tico del horario de verano Inicio del horario de verano Segun Domingo de Mar Finalizaci n del horario de verano Primer ing de Nc 2011 Schneider Electric Reservados todos los derechos 23 Pasarela Ethernet EGX300 de PowerLogic Configuraci n Sincronizaci n horaria de red 24 63230 319 216B2 11 2011 La habilitaci n de la sincronizaci n de la hora de la red permite ajustar la hora y la fecha del reloj del sistema EGX mediante un servidor de protocolo de hora de la red NTP NOTA Si el servidor NTP no est situado en el mismo segmento de red Ethernet que la EGX aseg rese de configurar correctamente la pasarela predeterminada de la EGX 1 Seleccione la casilla de verificaci n Activar Revela la secci n Par metros de SNTP y la sincronizaci n horaria de red en la p gina Ultima sincronizaci n horaria realizada Fecha y hora correctamente 2 Configure la desviaci n de zona horaria el Configura los par metros
420. values Data Type Select Holding Registers Input Registers Output Holding Registers Coils Input Coils or Device ID Decimal Hexadecimal Select an option to specify how the Value column Decimal Bin r ASCII options data is displayed ame D evice N The address Local ID of the device that is to be ary O 54 2011 Schneider Electric All Rights Reserved 63230 319 216B2 11 2011 Communications Check Automated Communications Check Manual Communications Check 2011 Schneider Electric All Rights Reserved PowerLogic Ethernet Gateway EGX300 Diagnostics When browsing the Real Time Data views the EGX has an automated communications check thatruns every 15 minutes by default To change the timing see Preferences on page 32 This check will verify the communications health of all devices configured on the EGX and will attempt to re establish communication to any device marked Out of Service within the current browser session In certain cases you may not want to wait for the automated communications check interval and need to force the check to run manually 1 From the Diagnostics menu click Opens the Communications Check page Communications Check 2 Click Check Device Status Runs a communications check Communicating devices display Passed in the Comms column and In Service in the Status column A device that is not communicating displays Failed in the Comms column and Out of Service
421. ves the firmware upd file in the designated a local directory file folder where the directory folder firmware file will be stored then click Save 2011 Schneider Electric All Rights Reserved 57 PowerLogic Ethernet Gateway EGX300 63230 319 216B2 Firmware 11 2011 Updating the Firmware Do not remove power from the EGX while firmware is being downloaded If power is removed during the programming process the EGX will no longer function The Status LED will rapidly blink while programming is in progress When the flashing stops programming is complete Launch Windows Explorer type ftp and Opens the Log On As dialog box the IP address of the EGX in the Address text box for example ftp 169 254 0 10 then press Enter Type the user name Administrator and the Opens an FTP session with the EGX administrator password in the text boxes then click Log On Locate the saved firmware file Copies the firmware file to the clipboard egxxxxx bin directory folder on your computer right click on the file name then click Copy Right click in the Windows Explorer Copies the firmware to the EGX and the EGX window then click Paste reboots NOTE Instead of copying and pasting the NOTE The Power Status light will blink firmware file you can drag and drop the rapidly while the file is being transferred firmware file into Window Explorer and programmed to the EGX Once the programming is complete the EGX will re
422. x Datos del registro de dispositivos S lo lectura S lo lectura S lo lectura ly Ninguna iv Restablecimientos S lo lectura S lo lectura M S lo lectura we Ninguna M Estadisticas S lo lectura M S lo lectura S lo lectura lv Ninguna lao Lectura de registros de dispositivo S lo lectura W S lo lectura S lo lectura y Ninguna EA Comprobaci n de las comunicaciones S lo lectura M S lo lectura S lo lectura y Ninguna v Registro de mantenimiento S lo lectura S lo lectura S lo lectura iy Ninguna M Ethernet y TCP IP S lo lectura M S lo lectura IS S lo lectura Ninguna Puerto serie S lo lectura x l S lo lectura w S lo lectura iy Ninguna x Conexiones con dispositivos remotos Completo iv Completa v Completo lv S lo lectura Lista de dispositivos S lo lectura M S lo lectura Imj S lo lectura Ninguna M Registro de dispositivos S lo lectura S lo lectura x S lo lectura Ninguna M Exportaci n del registro de dispositivos S lo lectura iv S lo lectura we S lo lectura y Ninguna y V nculos de documentaci n S lo lectura M S lo lectura lo S lo lectura ly Ninguna Rd Preferencias S lo lectura ve S lo lectura M S lo lectura ly Ninguna M o lectura M device shtml S lo ectura
423. x liens de documentation utilisateur Commande R initialisations Pr voit l ex cution des r initialisations d finies pour 4 l appareil et affiche la date et l heure laquelle chaque op ration a t ex cut e Les r initialisations de date et heure n apparaissent que si l appareil offre cette fonction Diagnostics Statistiques Affiche les donn es de diagnostic utilis es pour rechercher des probl mes sur le r seau Cette page contient galement des informations sur votre passerelle EGX notamment le num ro de s rie la date de fabrication et l adresse MAC Media Access Control contr le d acc s au support Lecture de registres Permet aux utilisateurs de lire les donn es de registres d appareils des appareils connect s la passerelle EGX localement et distance 9 V rification des Effectue une v rification des communications de tous 5 communications les appareils configur s sur la passerelle EGX Maintenance Journal de maintenance Affiche la date et l heure de la derni re maintenance 5 r alis e sur l quipement l utilisateur qui l a effectu e 50 54 5 6 ainsi que des d tails concernant l objet de cette maintenance 2011 Schneider Electric Tous droits r serv s 63230 319 216B2 11 2011 CONFIGURATION Param tres Ethernet et TCP IP 2011 Schneider Electric Tous droits r serv s Passerelle Ethernet PowerLogic EGX300 Configuration Pour acc der aux l
424. y then enter the maintenance text in user to enter maintenance details the Entry Detail text box see Figure 51 below Figure 50 Maintenance Log Maintenance Log Delete Entries l Delete Log Add Log Entry Delete Date and Time User Entry Detail 2010 05 10 14 09 Administrator F Test Figure 51 Add Log Entry Maintenance Log Date and Time User Entry Detail 2011 11 17 15 42 Administrator Ei Apply FIRMWARE Firmware on the EGX can be updated using File Transfer Protocol FTP Check www powerlogic com or with your local sales representative for the latest firmware update Finding the Firmware Version The EGX consists of two firmware components the executable binary component and the file image component 56 2011 Schneider Electric All Rights Reserved 63230 319 216B2 PowerLogic Ethernet Gateway EGX300 11 2011 Firmware Executable Binary Component Firmware Version 1 Open the web browser and log into the Opens the EGX home page EGX 2 Locate the firmware version on the Determines the firmware version of the EGX bottom left corner of the page NOTE If you recently updated your firmware press F5 to refresh the web page and update the displayed firmware number 3 Alternatively you can select Diagnostics Also determines the firmware version of the gt Statistics to find the firmware version in EGX the Gateway Information
425. ypen Pr fpfad Systemzugangspunkt berwachung Echtzeitdaten Ger teaufzeichnung Instrumententafeln Systemzugangspunkt Konfiguration der Parameter f r die serielle Kommunikation Konfiguration der Modbus TCP IP Verbindungen zu entfernten Ger ten 10 Konfiguration Erkennung oder berpr fung von lokalen 12 seriellen Ger ten in der Ger tekette Entfernte Ger te k nnen nur konfiguriert oder berpr ft werden Konfiguration der Parameter f r die Ger teaufzeichnung Konfiguration der Optionen f r den Ger teprotokollexport Einstellung des Datums und der Uhrzeit entweder manuell oder mit SNTP Parametern Konfiguration des Simple Network Management Protocol SNMP Festlegung der IP Adressen die auf das EGX ber Modbus TCP IP zugreifen k nnen Konfiguration der Datei und URL Links der Unterlagen Erstellung und Bearbeitung von Gruppen und Benutzern Konfiguration der Webseiten Zugriffsrechte f r jede Benutzergruppe 17 19 23 25 25 26 28 29 Konfiguration der EGX Pr ferenzen 32 0 wo Konfiguration der unterst tzten Ger tetypen die auf der Webseite EGX Ger teliste anzeigbar sind Konfiguration der Weiterleitung von Systemmeldungen durch das EGX ber das Wartungsprotokoll per E Mail oder ber den entfernten Syslog Server a Aktivierung und Konfiguration der Gruppen IP Adresse f r mehrere EGX300 Ger te damit sie sich gegenseitig erkennen und ihre Daten l