1. Abk rzungen Die nachfolgend aufgef hrten Fachbegriffe bzw Abk rzungen stellen keine vollst ndige Aufz hlung aller gebr uchlichen Fachbegriffe bzw Abk rzungen dar AC Alternating Current ACPI Advanced Configuration and Power Interface ANSI American National Standards Institute ASR amp R Automatic Server Reconfiguration and Restart BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller BTU British Thermal Unit cc Cache Coherency CD ROM Compact Disk Read Only Memory CHS Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor Options Guide RX600 S3 71 Abk rzungen COM Communications CPU Central Processing Unit DC Direct Current DIMM Dual Inline Memory Module DIP Dual Inline Package DMA Direct Memory Access DMI Desktop Management Interface DVD Digital Versatile Disk ECC Errror Checking and Correcting ECP Extended Capabilities Port EEPROM Electrically Erasable Programmable Read Only Memory EFI Extensible Firmware Interface EGB Elektrostatisch gefahrdete Bauteile EIA Electronic Industries Alliance 72 Options Guide RX600 S3 Abk rzungen ElektroG Elektro und Elektronikger tegesetz Umsetzung der EU Richtlinien RoHS und WEEE in deutsches Recht EMP Emergency Management Port EPP Enhanced Parallel Port EMV Elektromagnetische Vertr glichkeit electromagnetic compatibility EPROM Era
2. Bei Altger ten kann die R cknahme abgelehnt werden wenn diese Ger te aufgrund einer Verunreinigung ein Risiko f r die menschliche Gesundheit oder Sicherheit darstellen Wiederverwendung Recycling und Verwertung Durch die aktive Nutzung der angebotenen R ckgabe und Sammelsysteme leisten Sie Ihren Beitrag zur Wiederverwendung zum Recycling und zur Verwertung von Elektro nik Altger ten Auswirkungen auf die Umwelt und die menschliche Gesundheit Elektro nik Altger te enthalten Bestandteile die gem EU Richtlinie selektiv zu behandeln sind Getrennte Sammlung und selektive Behandlung sind die Basis zur umweltgerechten Entsorgung und zum Schutz der menschlichen Gesundheit Bedeutung des Symbols Durchgestrichene Abfalltonne auf R dern Elektro nik Ger te die mit einem der nachfolgenden Symbole gekenn zeichnet sind d rfen gem EU Richtlinie nicht mit dem Siedlungsabfall Hausm ll entsorgt werden Bild 2 Kennzeichnungen f r Elektro nik Ger te 20 Options Guide RX600 S3 Wichtige Hinweise Umweltschutz R ckgabe Batterien Batterien die mit einem der nachfolgenden Symbole gekennzeichnet sind d r fen gem EU Richtlinie nicht zusammen mit dem unsortierten Siedlungsabfall Hausm ll entsorgt werden A Bild 3 Kennzeichnungen auf Batterien Bei schadstoffhaltigen Batterien ist das chemische Zeichen fiir das enthaltene Schwermetall
3. Der Ein Ausbau der hot plug Komponenten ist in der Betriebsanleitung des Servers beschrieben Options Guide RX600 S3 5 bersicht ber die Dokumentation Einleitung Zus tzliche Dokumentation des Servers Die PRIMERGY Dokumentation besteht aus folgenden zus tzlichen Hand b chern Handbuch Sicherheit Druckexemplar welches immer mitgeliefert wird sowie als PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Handbuch Garantie Druckexemplar welches immer mitgeliefert wird sowie als PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Handbuch Ergonomie PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Betriebsanleitung zu PRIMERGY RX600 S3 PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Technisches Handbuch zur Systembaugruppe D2352 PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Handbuch D2352 BIOS Setup Utility for PRIMERGY RX600 S3 TX600 S3 PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Service Supplement zu PRIMERGY RX600 S3 PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Handbuch ServerView Suite Druckexemplar welches immer mitgeliefert wird sowie als PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Handbuch WebBIOS Configuration Utility PDF Datei verf gbar auf der mitgelieferten ServerBooks CD Eine Ersatz ServerBooks CD kann unter Angabe
4. Bau gruppe mit einem vollst ndig unabh ngigen System d h es verf gt ber ein eigenes Betriebssystem mit Web Server und SNMP Agenten Zudem kann es optional mit einer externen Stromversorgung versehen werden Das RSB S2 LP wird in einen non hot plug Standard PCl Steckplatz einge baut und ber Kabel mit der Systembaugruppe verbunden Das RSB S2 LP erm glicht Remote Diagnose zur Systemanalyse Remote Systemkonfiguration und einen Remote Restart auch bei Ausfall des Betriebs systems oder Hardware Fehlern Es verf gt ber einen eigenen LAN Port ber den alle Funktionen zur Verf gung stehen 8 Options Guide RX600 S3 Einleitung Darstellungsmittel 13 Darstellungsmittel In diesem Handbuch werden folgende Darstellungsmittel verwendet Kurisve Schrift kennzeichnet Befehle Men punkte oder Software Programme Anf hrungszeichen kennzeichnen Kapitelnamen und Begriffe die hervor gehoben werden sollen gt kennzeichnet einen Arbeitsschritt den Sie ausf hren m ssen ACHTUNG kennzeichnet Hinweise bei deren Nichtbeachtung Ihre Gesundheit die Funktionsf higkeit Ihres Servers oder die Sicherheit Ihrer Daten gef hrdet sind D kennzeichnet zus tzliche Informationen und Tipps Tabelle 1 Darstellungsmittel Options Guide RX600 S3 9 2 Vorgehensweise T ACHTUNG e Die in diesem Handbuch beschriebenen T tigkeiten d rfen nur von Technikern Servicepersonal oder
5. Zoll auf Zus tzliche Controller in non hot plug PCI Steckpl tzen Die Systembaugruppe verf gt ber sieben PCI Steckpl tze e Die Steckpl tze 1 5 sind hot plug PCI Steckpl tze die mit hot plugf higen Controllern best ckt werden k nnen die hot plug PCI Steckpl tze werden in der Betriebsanleitung beschrieben e Die PCI Steckpl tze 6 und 7 sind non hot plug PCI Steckpl tze und werden mit 100 MHz getaktet Sie k nnen Baugruppen mit einer L nge bis zu 315 mm aufnehmen Zus tzliche externe SCSI Schnittstelle Sollen zus tzliche externe SCSI Ger te angeschlossen werden kann ein Kanal des Onboard Controllers ber die externe SCSI Schnittstelle zum Anschluss von Speichersubsystemen zur Verf gung gestellt werden Options Guide RX600 S3 7 Erweiterungen und Umr stungen Einleitung Batterie BBU f r den RoMB Controller Optional ist f r den internen RoMB Controller eine Batterie Battery Backup Unit BBU verf gbar um dessen Speicherinhalte auch bei Netzausfall zu sichern RemoteView RemoteView ist die Remote Management L sung von Fujitsu Siemens Compu ters f r PRIMERGY Systeme RemoteView und die entsprechenden auf der Sys tembaugruppe integrierten Hardware Komponenten erm glichen eine Fern berwachung und wartung sowie eine schnelle Wiederherstellung der Betriebsbereitschaft im Fehlerfall RemoteView Service Board S2 LP Das RemoteView Service Board S2 low profile RSB S2 LP ist eine PCI
6. den Einbaurahmen auf Wenn Sie das Laufwerk wieder ausbauen und kein neues Laufwerk daf r einsetzen m ssen Sie den Einbaurahmen zum Zweck der K hlung der Einhaltung der EMV Vor schriften und des Brandschutzes erneut einsetzen Options Guide RX600 S3 51 Bandlaufwerk einbauen Bedienbare Laufwerke Bild 35 Befestigen der Gleitschienen am Laufwerk Befestigen Sie die Gleitschienen an beiden Seiten des zu installierenden Laufwerks mit je zwei Schrauben Bild 36 Einschieben des Bandlaufwerks gt Schieben Sie das bedienbare Laufwerk in den Laufwerksschacht bis es ein rastet 52 Options Guide RX600 S3 Bedienbare Laufwerke Bandlaufwerk einbauen Bandlaufwerk montieren Bild 37 Laufwerk anschlie en gt Stecken Sie das Datenkabel A an das Laufwerk Stecken Sie das Kabel f r die Spannungsversorgung B an das Laufwerk Stecken Sie das freie Ende des Datenkabels entweder auf den Anschluss SCSI B auf der Systembaugruppe oder auf einen freien Anschluss eines PCI SCSI Controllers Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben Options Guide RX600 S3 53 8 Controller in non hot plug PCI Steckpl tzen T ACHTUNG Beachten Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff Die Systembaugrup
7. 22 Einsetzen der Prozessorabdeckung gt Setzen Sie die Prozessorabdeckung wieder ein Achten Sie darauf dass die Prozessorabdeckung vollst ndig einras tet Dr cken Sie dazu auf die gekennzeichneten Stellen s Kreise auf der Abdeckung Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben 40 Options Guide RX600 S3 Prozessoren Prozessor austauschen 6 2 Prozessor austauschen ACHTUNG Es d rfen nur gleichartige Prozessoren auf der Systembaugruppe ver wendet werden gt ffnen Sie den Server wie in Kapitel Vorbereitung auf Seite 23f beschrie ben Entfernen Sie die Prozessorabdeckung siehe Seite 32 ab o Bild 23 Prozessor K hlk rper entfernen Entfernen Sie die vier Schrauben des K hlk rpers L sen Sie dabei zuerst 2 diagonal gegen berliegende Schrauben an danach die beiden anderen Schrauben gt Lockern Sie den K hlk rper vorsichtig durch seitliches Hin und Herdrehen Heben Sie ihn dann nach oben ab gt Entfernen Sie die berreste der Warmeleitpaste auf der Unterseite des K hlk rpers Options Guide RX600 S3 41 Prozessor austauschen Prozessoren gt Reinigen Sie die Unterseite des K hlk rpers mit einem fusselfreien Tuch Bild 24 Alten Prozessor ausbauen L sen Sie den Sockelheber indem Sie ihn z
8. Alle verwendeten Prozes soren m ssen bez glich Taktfrequenz und Cachegr e identisch sein F r den Multiprozessor Betrieb m ssen Sie ein geeignetes Multiprozes sor Betriebssystem verwenden ffnen Sie den Server wie in Kapitel Vorbereitung auf Seite 23f beschrie ben Options Guide RX600 S3 31 Weitere Prozessoren einbauen Prozessoren Prozessorabdeckung entfernen Bild 13 Entnehmen der Prozessorabdeckung gt Greifen Sie in die beiden Aussparungen der Prozessorabdeckung und neh men Sie sie nach oben ab 32 Options Guide RX600 S3 Prozessoren Weitere Prozessoren einbauen Blindeinsatz des Prozessor K hlk rpers entfernen Bild 14 K hlk rper Blindeins tze auf den CPU Pl tzen 2 4 Entfernen Sie den Blindeinsatz von dem betreffenden Prozessorsockel L sen Sie dazu die vier unverlierbaren Schrauben am Fu des Blindein satzes Beachten Sie bei der Best ckung Die Nummerierung der CPUs bzw CPU Sockel entspricht der Best ckungsreihenfolge Options Guide RX600 S3 33 Weitere Prozessoren einbauen Prozessoren Prozessor einbauen Bild 15 Sockelheber ffnen L sen Sie den Sockelheber indem Sie ihn zur Seite dr cken und schwen ken Sie ihn dann bis zum Anschlag nach oben Bild 16 Prozessor einsetzen T ACHTUNG Der Prozessor kann nur in einer bestimmten Ausrichtung eingebaut wer den Achten Sie dabei auf die Markie
9. Ihrer Rechnerdaten ber folgende Email Adresse bestellt werden Reklamat PC LOG fujitsu siemens com Weitere Informationsquellen Technisches Handbuch zum entsprechenden Rack Handbuch zum Bildschirm Handbuch zum Server Management ServerView Handbuch zum Remote Test und Diagnosesystem RemoteView Dokumentation zu Baugruppen und Laufwerken Dokumentation zu Ihrem Betriebssystem Informationsdateien zu Ihrem Betriebssystem siehe auch Kapitel Literatur auf Seite 79 6 Options Guide RX600 S3 Einleitung Erweiterungen und Umr stungen 1 2 Erweiterungen und Umr stungen Weitere Prozessoren Die Systembaugruppe kann auf bis zu vier Prozessoren hochger stet werden Es d rfen nur gleichartige Prozessoren auf der Systembaugruppe verwendet werden Alle Prozessoren m ssen bez glich Taktfrequenz und Cachegr e identisch sein Erweiterung des Hauptspeichers Auf der Systembaugruppe ist Platz f r vier hot plug Speicherboards von denen jedes mit bis zu vier Speichermodulen in zwei Speicherb nken best ckt wer den kann Die Einbaupl tze sind f r DDR 11 400 MHz DIMM Speichermodule mit einer Kapazit t von 1 Gbyte 2 Gbyte und 4 Gbyte geeignet Der maximale Speicherausbau betr gt 64 Gbyte Zus tzliches bedienbares Laufwerk Zus tzlich zum vorhandenen CD DVD Laufwerk kann als bedienbares Lauf werk ein Bandlaufwerk integriert werden Der Einbauplatz nimmt Ger te des Formats 5 25 x 1 6
10. PRIMERGY RX600 S3 Server Options Guide Ausgabe Juli 2006 Kritik Anregungen Korrekturen Die Redaktion ist interessiert an Ihren Kommentaren zu diesem Handbuch Ihre R ckmeldungen helfen uns die Dokumentation zu optimieren und auf Ihre W nsche und Bed rfnisse abzustimmen F r Ihre Kommentare stehen Ihnen Fax Formulare auf den letzten Seiten dieses Handbuchs zur Verf gung Dort finden Sie auch die Adressen der zust ndigen Redaktion Zertifizierte Dokumentation nach DIN EN ISO 9001 2000 Um eine gleichbleibend hohe Qualit t und Anwenderfreundlichkeit zu gew hrleisten wurde diese Dokumentation nach den Vorgaben eines Qualit tsmanagementsystems erstellt welches die Forderungen der DIN EN ISO 9001 2000 erf llt cognitas Gesellschaft f r Technik Dokumentation mbH www cognitas de Copyright und Handelsmarken Copyright 2006 Fujitsu Siemens Computers GmbH Alle Rechte vorbehalten Lieferm glichkeiten und technische nderungen vorbehalten Alle verwendeten Hard und Softwarenamen sind Handelsnamen und oder Warenzeichen der jeweiligen Hersteller Inhalt 1 ElnleitUNQ lt lt lt lt lt lt 5 1 1 bersicht ber die Dokumentation 5 1 2 Erweiterungen und Umr stungen i 1 3 Darstellingsmittel lt lt o oe GeO 80 an A 9 2 Vorgehensweise o ee ees 11 3 Wichtige Hinweise lt 13 31 Sicherheitshinweis
11. X600 S3 Hauptspeicher Hauptspeicher erweitern austauschen Bild 11 Speichermodul einbauen Stecken Sie das Speichermodul in den Einbauplatz 1 bis die seitlichen Auswurfhebel am Speichermodul einrasten 2 254768 001 Setzen Sie die Abdeckung auf das Speicherboard siehe Seite 28 gt Stecken Sie das Speicherboard vorsichtig an seinen Platz im Server Dr cken Sie dabei gleichm ig auf beiden Seiten des Boards Eine ausf hr liche Beschreibung des Einbaus finden Sie in der Betriebsanleitung Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben Options Guide RX600 S3 29 6 A 6 1 Prozessoren ACHTUNG Beachten Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff Prozessoren sind Bausteine welche auf elektrostatische Entladungen u erst empfindlich reagieren k nnen und daher stets mit Vorsicht zu behandeln sind Nach Entnahme eines Prozessors aus seiner Schutzh lle oder aus einem Sockel legen Sie ihn mit seiner glatten Oberfl che auf eine nicht leitende antistatische Oberfl che Schieben Sie nie einen Prozessor ber eine Oberfl che Weitere Prozessoren einbauen Die Systembaugruppe kann auf bis zu vier Prozessoren hochger stet werden A ACHTUNG Verwenden Sie nur gleichartige Prozessoren
12. bei hohen Lauf werksgeschwindigkeiten brechen Datenverlust Unter Umst nden k nnen scharfkantige CD DVD Bruchst cke die Abdeckung des CD DVD Laufwerks durchdringen Besch digungen am Ger t und aus dem Ger t geschleudert werden Verletzungs gefahr insbesondere an unbedeckten K rperpartien wie Gesicht oder Hals Sie schonen das CD DVD ROM Laufwerk und verhindern mechanische Besch digungen sowie vorzeitigen Verschlei der CDs indem Sie fol gende Ratschl ge beachten Legen Sie die CDs DVDs nur bei Bedarf ins Laufwerk und entnehmen Sie sie nach Gebrauch Bewahren Sie die CDs DVDs in geeigneten H llen auf Sch tzen Sie die CDs DVDs vor Hitze und direkter Sonneneinstrah lung Laserhinweis Das CD DVD Laufwerk entspricht der Laser Klasse 1 nach IEC 60825 1 T ACHTUNG Das CD DVD Laufwerk enth lt eine Licht emittierende Diode LED die unter Umst nden einen st rkeren Laserstrahl als Laser Klasse 1 erzeugt Direkter Blick in diesen Strahl ist gef hrlich Entfernen Sie niemals Geh useteile des CD DVD Laufwerks Options Guide RX600 S3 17 Sicherheitshinweise Wichtige Hinweise Komponenten mit elektrostatisch gef hrdeten Bauelementen Komponenten mit elektrostatisch gef hrdeten Bauelementen EGB sind durch folgenden Aufkleber gekennzeichnet A Wenn Sie Komponenten mit EGB handhaben m ssen Sie folgende Hinweise unbedingt befolgen Bild 1 EGB Kennzeichen e Ziehen Sie
13. ben tigten Handb cher sind als PDF Datei ber das Internet als Download kostenlos erh ltlich Die Einstiegsseite der im Inter net verf gbaren Online Dokumentation finden Sie unter folgender URL http manuals fujitsu siemens com Zur Dokumentation der PRIMERGY Server gelangen Sie ber den Navigationspunkt industry standard servers 1 PRIMERGY RX600 S3 Betriebsanleitung 2 PRIMERGY RX600 S3 Service Supplement 3 Systembaugruppe D2352 f r PRIMERGY RX600 S3 TX600 S3 Technisches Handbuch 4 D2352 BIOS Setup Utility for PRIMERGY RX600 S3 TX600 S3 Referenzhandbuch 5 PRIMERGY ServerView Suite ServerStart Benutzerhandbuch 6 PRIMERGY ServerView Suite ServerView S2 Servermanagement Benutzerhandbuch 7 PRIMERGY ServerView Suite ServerView Servermanagement Benutzerhandbuch 8 ServerView Extension ServerView Extension f r HP OpenView NNM 9 ServerView Plus f r Tivoli Options Guide RX600 S3 79 Literatur 10 11 12 13 14 15 16 17 PRIMERGY ServerView Suite RemoteView Benutzerhandbuch LocalView Benutzerhandbuch User Manual 19 Zoll Rack 19 Inch Rack Technisches Handbuch DataCenter Rack Technisches Handbuch PRIMECENTER Rack Technisches Handbuch Global Array Manager Client Software Benutzerhandbuch Global Array Manager Server Software Benutzerhandbuch WebBIOS Configuration Utility User s Guide 18 Sicherheit 19 Garantie 20 Ergono
14. cken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben 56 Options Guide RX600 S3 9 RemoteView Komponenten T ACHTUNG Beachten Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff Das RemoteView Service Board S2 LP RSB S2 LP ist eine PCI Baugruppe im low profile Format mit einem vollst ndig unabh ngigen System d h es verf gt ber ein eigenes Betriebssystem mit Web Server und SNMP Agenten und kann optional mit einer externen Stromversorgung versehen werden Das RSB S2 LP wird ber ein IPMB Kabel mit der Systembaugruppe verbun den Es erm glicht Remote Diagnose zur Systemanalyse Remote Systemkon figuration und einen Remote Restart auch bei Ausfall des Betriebssystems oder Hardware Fehlern 9 1 RemoteView Service Board S2 LP einbauen ffnen Sie den Server wie in Kapitel Vorbereitung auf Seite 23f beschrie ben Entfernen Sie die Slot Abdeckung eines non hot plug PCI Steckplatzes an der R ckseite des Servers Das RSB S2 LP ist bevorzugt in den non hot plug PCI Steckplatz 7 einzubauen Bewahren Sie die Slot Abdeckung auf Wenn Sie die Baugruppe ausbauen m ssen Sie die Slot Abdeckung wegen der K hlung der einzuhaltenden EMV Vorschriften und des Brandschutzes wieder einsetzen Options Guide RX600 S3 57 RemoteView Service Board S2 LP einbauen RemoteView Kompo
15. die Netzstecker bevor Sie Komponenten stecken oder ziehen e Sie m ssen sich statisch entladen z B durch Ber hren eines geerdeten Gegenstandes bevor Sie mit den Komponenten arbeiten e Verwendete Ger te und Werkzeuge m ssen frei von statischer Aufladung sein e Verwenden Sie ein f r diese Zwecke geeignetes Erdungskabel welches Sie bei der Montage von Komponenten mit der Systemeinheit verbindet e Fassen Sie die Komponenten nur an den Kanten bzw gr n markierten Stel len Touch Point an e Ber hren Sie keine Anschlussstifte oder Leiterbahnen auf einer Baugruppe e Legen Sie alle Bauteile auf eine Unterlage die frei von statischen Aufladun gen ist Eine ausf hrliche Beschreibung f r die Behandlung von EGB Kompo nenten ist in den einschl gigen europ ischen bzw internationalen Nor men DIN EN 61340 5 1 ANSI ESD S20 20 zu finden 18 Options Guide RX600 S3 Wichtige Hinweise Umweltschutz 3 2 Umweltschutz Umweltgerechte Produktgestaltung und entwicklung Dieses Produkt wurde nach der Fujitsu Siemens Computers Norm Umwelt gerechte Produktgestaltung und entwicklung konzipiert Das bedeutet dass entscheidende Kriterien wie Langlebigkeit Materialauswahl und kennzeich nung Emissionen Verpackung Demontagefreundlichkeit und Recyclingf hig keit ber cksichtigt wurden Dies schont Ressourcen und entlastet somit die Umwelt Hinweis zum sparsamen Energieverbrauch Bitte schalten Sie Ger te
16. die nicht st ndig eingeschaltet sein m ssen erst bei Gebrauch ein sowie bei l ngeren Pausen und bei Arbeitsende wieder aus Hinweis zum Umgang mit Verbrauchsmaterialien Bitte entsorgen Sie Drucker Verbrauchsmaterialien und Batterien gem den landesrechtlichen Bestimmungen Batterien geh ren nicht in den Hausm ll Sie werden vom Hersteller H ndler oder deren Beauftragten kostenlos zur ckgenommen um sie einer Verwertung bzw Entsorgung zuzuf hren Hinweis zu Aufklebern auf Kunststoff Geh useteilen Bitte kleben Sie m glichst keine eigenen Aufkleber auf Kunststoff Geh use teile da diese das Recycling erschweren Options Guide RX600 S3 19 Umweltschutz Wichtige Hinweise R ckgabe Elektro und Elektronik Altger te Getrennte Sammlung Nutzer von Elektro und Elektronikger ten sind verpflichtet die Altger te getrennt zu sammeln Elektro nik Altger te d rfen nicht gemeinsam mit dem unsortierten Siedlungsabfall Hausm ll beseitigt werden Die getrennte Sammlung ist Voraussetzung fiir die Wiederverwendung das Recycling und die Verwertung von Elektro nik Altgeraten Dadurch werden Ressourcen geschont R ckgabe und Sammelsysteme Elektro nik Altger te aus privaten Haushalten k nnen kostenlos zur ckge geben werden F r die R ckgabe Ihres Altger tes nutzen Sie bitte die Ihnen zur Verf gung stehenden l nderspezifischen R ckgabe und Sammelsys teme siehe Ansprechpartner vor Ort auf Seite 21
17. e 2 2 2 22 m mn nn 13 3 2 Umwellsenutz lt lt a 26 22 he Eimer 19 4 Vorberetung s ia bee Kan aan nn 23 4 1 Server D NEN de aod a aa A eA e KC 23 5 Hauptspeicher 242 28 aan 25 5 1 Best ckungsvorschriften 26 5 2 Hauptspeicher erweitern austauschen 27 6 Prozessoren sa aa ke a asa sd 31 6 1 Weitere Prozessoren einbauen 31 6 2 Prozessor austauschen 22 2 2 a nn 41 7 Bedienbare Laufwerke 2 2 222 nn m m u nun 45 2 1 CD DVD Laufwerk einbauen 45 7 2 Bandlaufwerk einbauen 50 8 Controller in non hot plug PCI Steckpl tzen 55 8 1 Controller einbauen 55 9 RemoteView Komponenten 57 91 RemoteView Service Board S2 LP einbauen 57 10 Externer SCSI Anschluss 2 2 2 222222200 61 10 1 Externen SCSI Anschluss einbauen 62 11 Batterie f r RoMB Controller 65 11 1 Batterie BBU einbauen nk ee 0a 65 12 Fertigstellung lt lt es Re nn 69 12 1 Server schlie en 69 ADRKUTZINGEN a cia e e e se 71 Options Guide RX600 S3 Inhalt Literatur Stichwearler capres ea Bille a A A AA RE E Options Guide RX600 S3 1 Einleitung Der Server PRIMERGY RX600 S3 ist ein Intel basierter Server f r mittlere und gro e Unternehmen Er eignet sich sowohl f r File Server Dienste als auch als Anwendungs Inf
18. e RX600 S3 43 7 Bedienbare Laufwerke ACHTUNG Beachten Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff Der Server PRIMERGY RX600 S3 bietet insgesamt zwei Einbaupl tze f r bedienbare Laufwerke Zur Auswahl stehen ein Bandlaufwerk und ein CD DVD Laufwerk 7 1 CD DVD Laufwerk einbauen Bild 26 CD DVD Laufwerk mit Einbaurahmen In den Server kann ein CD DVD Laufwerk B eingebaut werden Dieses Lauf werk wird in einem Einbaurahmen A in den Server eingebaut Einbaurahmen ausbauen Der Einbaurahmen f r das CD DVD Laufwerk befindet sich im Einbauplatz gt ffnen Sie den Server wie in Kapitel Vorbereitung auf Seite 23f beschrie ben Options Guide RX600 S3 45 CD DVD Laufwerk einbauen Bedienbare Laufwerke a GC Bild 27 Einbaurahmen entneh Ms I men Dr cken Sie auf den blauen Hebel A und schieben Sie den Einbaurahmen nach vorn hinaus CD DVD Laufwerk montieren Bild 28 Montage der Schnittstellen Baugruppe gt Stecken Sie die Schnittstellen Baugruppe A in die r ckseitige Geh use ffnung B am CD DVD Laufwerk 46 Options Guide RX600 S3 Bedienbare Laufwerke CD DVD Laufwerk einbauen Bild 29 Laufwerk im Rahmen befestigen Legen Sie das CD DVD Laufwerk so in den Einbaurahmen dass es in die beiden Offnungen am Einbaurahmen siehe Kreise einhakt Bi Options Guide RX600 S3 CD DVD Laufwer
19. en Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff 11 1 Batterie BBU einbauen Bild 44 Bestandteile des optionalen BBU Pakets Batteriehalter B Batterie C Anschlusskabel zur Systembaugruppe ffnen Sie den Server wie in Kapitel Vorbereitung auf Seite 23f beschrie ben Entfernen Sie die im Installationsbereich befindlichen Speicherboards bzw Speicherboard Blindeins tze Einbaupl tze C und D Options Guide RX600 S3 65 Batterie BBU einbauen Batterie f r ROMB Controller Bild 45 Internes und externes Kabel an die Batterie anschlieBen Stecken Sie den Stecker des internen Kabels auf den internen Anschluss der Batterie A Stecken Sie den Stecker des Anschlusskabels zur Systembaugruppe durch die Offnung des Batteriehalters auf den externen Anschluss der Batterie B gt Schlie en Sie den Batteriehalter 66 Options Guide RX600 S3 Batterie f r ROMB Controller Batterie BBU einbauen Bild 46 Batteriehalter befestigen und Anschlusskabel verlegen gt Befestigen Sie den Batteriehalter in den daf r vorbereiteten Aussparungen an der Geh useseitenwand gt Verlegen Sie das Anschlusskabel durch die ffnung in der Luftleitfolie siehe Kreis in obiger Abb Options Guide RX600 S3 67 Batterie BBU einbauen Batterie f r RoMB Controller l MRE 9 Bild 47 An
20. et pages of Fujitsu Technology Solutions are available at http ts fujitsu com and the user documentation at hrrp manuals ts fujitsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochtergesellschaft von Fujitsu tr gt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor l ngerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion Bitte beachten Sie dass alle Firmenbez ge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions bergegangen sind Kontakt und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form ts fujitsu com Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http de ts fujitsu com und unter http manuals ts fujitsu com finden Sie die Benutzerdokumentation Copyright Fujitsu Technology Solutions 2009
21. ge des externen SCSI Anschlusses Options Guide RX600 S3 61 Externen SCSI Anschluss einbauen Externer SCSI Anschluss 10 1 Externen SCSI Anschluss einbauen Dazu ist das folgende Kabel FSC Nr A3C40065530 zu installieren Bild 42 Kabel f r den externen SCSI Anschluss Stecker f r den Anschluss externer SCSI Ger te B Stecker f r den Anschluss SCSI B auf der Systembaugruppe ffnen Sie den Server wie in pitel Vorbereitung auf Seite 23f beschrie ben Entfernen Sie die im Installationsbereich befindlichen Speicherboards bzw Speicherboard Blindeins tze Einbaupl tze C und D 62 Options Guide RX600 S3 Externer SCSI Anschluss Externen SCSI Anschluss einbauen SSS IS ISIS S ez AA Fu Y ar i D D Bild 43 Einsetzen des Steckers in die Server R ckwand Stecken Sie den Stecker A des Anschlusskabels in die entsprechende Offnung in der R ckwand D Achten Sie darauf dass der Stecker vollst ndig einrastet Stecken Sie den Stecker B des Anschlusskabels siehe Bild 42 auf Seite 62 auf den Anschluss SCSI B auf der Systembaugruppe Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben Options Guide RX600 S3 63 11 Batterie f r RoMB Controller T ACHTUNG Beacht
22. hl sse 58 Eigenschaften 8 nachr sten 57 R cknahme 20 S Speichermodule austauschen 27 U Umgang mit CDs 17 V VRM Module einbauen 36 Lage auf Systembaugruppe 38 Z Zeichenerkl rung 9 Zielgruppe 5 Zus tzliche Dokumentation 6 82 Options Guide RX600 S3 EE Fujitsu Siemens Computers GmbH Handbuchredaktion 33094 Paderborn Fax 0 700 372 00001 email manuals fujitsu siemens com http manuals fujitsu siemens com Kritik Anregungen Korrekturen Absender Kommentar za PRIMERGY RX600 S3 Server Options Guide EE Fujitsu Siemens Computers GmbH Handbuchredaktion 33094 Paderborn Fax 0 700 372 00001 email manuals fujitsu siemens com http manuals fujitsu siemens com Kritik Anregungen Korrekturen Absender Kommentar za PRIMERGY RX600 S3 Server Options Guide O FUJITSU Information on this document On April 1 2009 Fujitsu became the sole owner of Fujitsu Siemens Compu ters This new subsidiary of Fujitsu has been renamed Fujitsu Technology So lutions This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions Contact and support addresses will now be offered by Fujitsu Technology So lutions and have the format ts fujitsu com The Intern
23. hluss In Notf llen z B bei Besch digung von Geh use Bedienelementen oder Netzleitung bei Eindringen von Fl ssigkeiten oder Fremdk r pern schalten Sie das Ger t sofort aus ziehen Sie den die Netzste cker aus der den geerdeten Schutzkontakt Steckdose n und ver st ndigen Sie den Service Der bestimmungsgem e Betrieb des Systems gem IEC 60950 EN 60950 ist nur bei vollst ndig montiertem Geh use und eingebauten R ckseitenabdeckungen f r Einbaupl tze gew hr leistet elektrischer Schlag K hlung Brandschutz Funkentst rung Options Guide RX600 S3 15 Sicherheitshinweise Wichtige Hinweise A Batterien A ACHTUNG Installieren Sie nur Systemerweiterungen die den Anforderungen und Vorschriften f r Sicherheit elektromagnetische Vertr glichkeit und Telekommunikationsendger te Einrichtungen entsprechen Durch die Installation anderer Erweiterungen k nnen diese Anforde rungen und Vorschriften verletzt oder das System besch digt wer den Informationen dar ber welche Systemerweiterungen zur Installation zugelassen sind erhalten Sie von Ihrer Verkaufsstelle oder unserem Service Die mit einem Warnhinweis z B Blitzpfeil gekennzeichneten Kom ponenten d rfen nur von autorisiertem Fachpersonal ge ffnet aus gebaut oder ausgetauscht werden Ausnahme hot plug Netzteile d rfen ausgetauscht werden Die Gew hrleistung erlischt wenn Sie durch Einbau oder Austausch von Systemerwei
24. im Aufstellen und vor Betrieb des Ger tes eventuelle Hinweise f r die Umgebungsbedingungen Ihres Ger tes siehe Betriebsanleitung Wenn das Ger t aus kalter Umgebung in den Betriebsraum gebracht wird kann Betauung sowohl am Ger te u eren als auch im Ger teinneren auftreten Warten Sie bis das Ger t temperaturangeglichen und absolut tro cken ist bevor Sie es in Betrieb nehmen Nichtbeachtung der Vorga ben kann zu Sachsch den am Ger t f hren Transportieren Sie das Ger t nur in der Originalverpackung oder in einer anderen geeigneten Verpackung die Schutz gegen Sto und Schlag gew hrt Inbetriebnahme und Betrieb ACHTUNG A Wird das Rack Modell in eine Installation integriert die von einem industriellen Versorgungsnetz mit dem Anschlussstecker des Typs 1EC309 gespeist wird muss die Absicherung des Versorgungsnetzes den Anforderungen f r nicht industrielle Versorgungsnetze f r den Steckertyp A entsprechen Der Server stellt sich automatisch auf eine Netzspannung zwischen 200 V und 240 V ein Stellen Sie sicher dass die rtliche Netzspan nung diesen Bereich weder ber noch unterschreitet Dieses Ger t ist mit sicherheitsgepr ften Netzleitungen ausger stet und darf nur an vorschriftsm ig geerdete Schutzkontakt Steck dosen angeschlossen werden Stellen Sie sicher dass die Steckdosen am Ger t oder die Schutz kontakt Steckdosen der Hausinstallation frei zug nglich ist Die Ein Aus Taste t
25. ise einzubauen Dabei sind pro Paar identische Speichermodule zu verwenden ES DIMM 28 E E mma ES Bild 6 Best ckung der Speicherb nke Die Speicherkapazit t der Paare eines Speicherboards hingegen darf unterschiedlich sein so kann z B das Paar 1A 1B mit zwei 2 Gbyte Speichermodulen und das Paar 2A 2B mit zwei 1 Gbyte Speichermodu len best ckt sein 26 Options Guide RX600 S3 Hauptspeicher Hauptspeicher erweitern austauschen 5 2 Hauptspeicher erweitern austauschen gt ffnen Sie den Server wie in Kapitel Vorbereitung auf Seite 23f beschrie ben Bild 7 Bet tigen der Grifflasche gt Dr cken Sie gegen die Lasche im Griff damit der Griff herausspringen kann Bild 8 Herausnehmen des Speicherboards Ziehen Sie das Speicherboard vorsichtig am Griff heraus Options Guide RX600 S3 27 Hauptspeicher erweitern austauschen Hauptspeicher Bild 9 Abdeckung des Speicherboards entfernen Entfernen Sie die Abdeckung auf dem Speicherboard durch Dr cken der markierten Laschen Dr cken Sie zuerst Lasche 1 und danach die Laschen 2 und 3 Bild 10 Speichermodul ausbauen Klappen Sie die Auswurfhebel des entsprechenden Einbauplatzes an bei den Seiten nach au en 1 Ein installiertes Speichermodul wird dadurch aus dem Steckplatz ausgeworfen gt Entnehmen Sie das Speichermodul 2 28 Options Guide R
26. k einbauen Bedienbare Laufwerke SAS Bild 31 CD DVD Laufwerk einschieben gt Schieben Sie das CD DVD Laufwerk von vorne in den Einbauschacht bis es einrastet 48 Options Guide RX600 S3 Bedienbare Laufwerke CD DVD Laufwerk einbauen ra Bild 32 CD DVD Laufwerk einbauen gt Stecken Sie das Datenkabel A und das Stromversorgungskabel B an die Schnittstellen Baugruppe des CD DVD Laufwerks Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben Options Guide RX600 S3 49 Bandlaufwerk einbauen Bedienbare Laufwerke 7 2 Bandlaufwerk einbauen In den Einbauplatz in der Mitte des Servers kann ein Bandlaufwerk eingebaut werden Ist der Einbauplatz unbest ckt so ist lediglich der Einbaurahmen ent halten Einbaurahmen ausbauen gt ffnen Sie den Server wie in Kapitel Vorbereitung auf Seite 23f beschrie ben Bild 33 Entnahme des Einbaurahmens Dr cken Sie auf die beiden blauen Fl chen der Federlaschen am Einbau rahmen und schieben Sie den Einbaurahmen nach vorne hinaus 50 Options Guide RX600 S3 Bedienbare Laufwerke Bandlaufwerk einbauen Bild 34 Einbaurahmen mit Gleitschienen gt Entfernen Sie die beiden seitlich angebrachten Gleitschienen durch L sen der Schrauben ACHTUNG Bewahren Sie
27. l Fertig stellung auf Seite 69f beschrieben gt Starten Sie das Betriebssystem und f hren Sie falls notwendig die ent sprechende Konfiguration aus siehe Betriebsanleitung Options Guide RX600 S3 11 3 Wichtge Hinweise In diesem Kapitel finden Sie Sicherheitshinweise die Sie beim Umgang mit Ihrem Server unbedingt beachten m ssen 3 1 Sicherheitshinweise Die nachfolgenden Sicherheitshinweise sind ebenfalls im Handbuch Sicherheit beschrieben Dieses Ger t entspricht den einschl gigen Sicherheitsbestimmungen f r Ein richtungen der Informationstechnik einschlie lich elektrischer B romaschinen f r den Einsatz in B roumgebung Falls Sie Fragen haben ob Sie das Ger t in der vorgesehenen Umgebung auf stellen k nnen wenden Sie sich bitte an Ihre Verkaufsstelle oder an unseren Service T ACHTUNG Die in dieser Anleitung beschriebenen T tigkeiten d rfen nur von techni schem Fachpersonal durchgef hrt werden Reparaturen am Ger t d r fen nur von autorisiertem Fachpersonal durchgef hrt werden Durch unbefugtes ffnen und unsachgem e Reparaturen k nnen Gefahren f r den Benutzer elektrischer Schlag Energiegefahr Brandgefahr bzw Sachsch den am Ger t entstehen Unerlaubtes ffnen des Ger tes hat den Garantieverlust und den Haftungsausschluss zur Folge Options Guide RX600 S3 13 Sicherheitshinweise Wichtige Hinweise Vor Inbetriebnahme ACHTUNG A Beachten Sie be
28. mie 80 Options Guide RX600 S3 Stichw rter A austauschen Batterie 16 Prozessor 41 Speichermodule 27 B Batterie austauschen 16 Batterie f r RoMB Controller 65 BBU 65 BBU Halter befestigen 67 Bedienbare Laufwerke nachr sten 7 Cc CD DVD Laufwerk nachr sten 45 Controller nachr sten 7 55 D Darstellungsmittel 9 E EGB Kennzeichen 18 Einbaurahmen f r bedienbare Laufwerke 51 f r das CD DVD Laufwerk 45 elektrostatisch gef hrdete Bauele mente EGB 18 entfernen Geh useabdeckung 24 Entsorgung 20 G Geh useabdeckung entfernen 24 montieren 69 H Hauptspeicher nachr sten 7 27 Informationsmaterial zum Server 6 K K hlk rper befestigen 35 Blindeinsatz entfernen 33 entfernen 33 L Laserhinweis 17 lichtemittierende Diode LED 17 Lithium Batterie austauschen 16 Luftleithaube einsetzen 39 f r VRM Modul 37 M Multiprozessor Betrieb 31 Multiprozessor Betriebssystem 31 N nachr sten bedienbare Laufwerke 7 CD DVD Laufwerk 45 Controller 55 ext SCSI Anschluss 61 Hauptspeicher 27 Prozessoren 31 RemoteView Service Board S2 LP 57 non hot plug PCI Controller 55 P Prozessor austauschen 41 K hlk rper entfernen 33 Multiprozessor Betrieb 31 Prozessorabdeckung entfernen 32 Prozessoren nachr sten 7 31 R RAID on Motherboard RoMB 65 Recycling 20 Options Guide RX600 S3 81 Stichw rter RemoteView Service Board S2 LP Eigenschaften 8 nachr sten 57 RSB S2 LP Ansc
29. nder Mehrzahl der F lle macht es Sinn den Server aus dem Rackschrank auszubauen Der Ausbau des Servers aus dem Rackschrank ist in der Betriebs anleitung beschrieben Bild 5 Abnehmen der Geh useabdeckung L sen Sie die beiden unverlierbaren Schrauben an der Stirnseite 1 gt Schieben Sie die Geh useabdeckung ein St ck nach hinten 2 Nehmen Sie die Geh useabdeckung ab 24 Options Guide RX600 S3 5 Hauptspeicher T ACHTUNG Beachten Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff Der Austausch von defekten Speicherboards kann bei redundanter il Mirror bzw RAID Konfiguration im laufenden Betrieb hot plug erfol gen Wie Sie dabei vorgehen m ssen ist in der Betriebsanleitung des Servers beschrieben In diesem Handbuch wird der Austausch bei ausgeschaltetem Ger t beschrieben Auf der Systembaugruppe ist Platz f r vier hot plug Speicherboards von denen jedes mit bis zu vier Speichermodulen best ckt werden kann Je zwei Speicher module 1A 1B bzw 2A 2B bilden eine sog Speicherbank siehe Bild 6 auf Seite 26 Die Einbaupl tze sind f r DDR 11 400 MHz DIMM Speichermodule mit einer Kapazit t von 1 Gbyte 2 Gbyte und 4 Gbyte geeignet Der maximale Speicher ausbau betr gt 64 Gbyte Options Guide RX600 S3 25 Best ckungsvorschriften Hauptspeicher 5 1 Bestuckungsvorschriften ACHTUNG Speichermodule sind immer paarwe
30. nenten Bild 39 Einbauplatz und Anschl sse des RSB S2 LP gt Installieren Sie das RSB S2 LP in den PCI Steckplatz Die Vorgehensweise ist im Kapitel Controller in non hot plug PCI Steckpl tzen auf Seite 55ff beschrieben 58 Options Guide RX600 S3 RemoteView Komponenten RemoteView Service Board S2 LP einbauen Bild 40 Anschl sse des RSB S2 LP 1 Anschluss f r das Adapterkabel Anschluss f r externe Spannungs versorgung sowie USB und VGA Anschluss Anschluss f r optionale Spannungsversorgung wird nicht benutzt IPMB Anschluss LAN Anschluss Stecken Sie das im Server bereitliegende IPMB Kabel in den entsprechen den Stecker siehe 3 in Bild 40 auf dem RSB S2 LP gt berpr fen Sie ob das IPMB Kabel auf der Systembaugruppe gesteckt ist siehe A in Bild 39 auf Seite 58 Die Lage der Stecker der Systembaugruppe ist im Technischen Handbuch zur Systembaugruppe D2352 beschrieben Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben Options Guide RX600 S3 59 10 Externer SCSI Anschluss ACHTUNG Beachten Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff Der Anschluss f r externe SCSI Ger te wird an der R ckseite des Servers ein gebaut Bild 41 La
31. ormations oder Internet Server Der Server bietet ein hohes Ma an Datensicherheit und Verf gbarkeit durch hoch entwickelte Hardware und Software Komponenten Hierzu z hlen Fest plattenlaufwerk Module Systeml fter Netzteile PCI Steckpl tze und Speicherboards alle aufgez hlten Komponenten sind hot plug f hig ebenso wie Prefailure Detection and Analysing PDA Automatic Server Reconfigu ration and Restart ASR amp R und die Server Management Software ServerView Der Server kommt ausschlie lich als Rack Modell zum Einsatz Er bietet viel faltige Ausbaum glichkeiten belegt jedoch lediglich vier H heneinheiten HE im 19 Zoll Rack 1 1 bersicht ber die Dokumentation PRIMERGY Handb cher finden Sie im PDF Format auf der ServerBooks CD die mit jedem Serversystem als Bestandteil des Pakets ServerView Suite ausgeliefert wird Diese PDF Dateien sind auch ber das Internet als Download kostenlos erh ltlich Unter http manuals fujitsu siemens com finden Sie eine ber sichtsseite mit der im Internet verf gbaren Online Dokumentation Zur Dokumentation der PRIMERGY Server gelangen Sie ber den Navi gationspunkt industry standard servers Konzept und Zielgruppen dieses Handbuchs Dieser Options Guide zeigt Ihnen wie Sie den Server erweitern und hochr sten k nnen T Achtung Die in diesem Handbuch beschriebenen T tigkeiten d rfen nur von tech nisch geschultem Fachpersonal durchgef hrt werden
32. pe enth lt zwei non hot plug PCI X Steckpl tze Slot 6 und Slot 7 mit folgenden Spezifikationen 64 Bit 100 MHz max L nge 315 mm Gehen Sie bei einem Tausch von nicht hot plug f higen Komponenten unbe dingt wie folgt vor Beenden Sie alle Anwendungen und fahren Sie den Server ordnungsgem herunter Falls Ihr Betriebssystem den Server nicht ausgeschaltet hat dr cken Sie die Ein Aus Taste Ziehen Sie alle Netzstecker aus den Schutzkontakt Steckdosen 8 1 Controller einbauen ffnen Sie den Server wie in Kapitel Vorbereitung auf Seite 23f beschrie ben gt Lesen Sie die mit der PCI Baugruppe gelieferte Dokumentation gt Stecken Sie eventuell ben tigte Kabel auf der PCI Baugruppe Entfernen Sie die Slot Abdeckung des betreffenden Einbauplatzes an der R ckseite des Servers Bewahren Sie die Slot Abdeckung auf Wenn Sie eine Baugruppe ausbauen m ssen Sie de Slot Abde ckung wegen der K hlung der einzuhaltenden EMV Vorschriften und des Brandschutzes wieder einsetzen Options Guide RX600 S3 55 Controller einbauen Controller in non hot plug PCI Steckpl tzen Bild 38 Einbau eines non hot plug Controllers F hren Sie den Controller in den Einbauplatz ein und dr cken Sie sie vor sichtig fest Schlie en Sie sodann die Slotverriegelung A gt Wenn erforderlich stecken Sie die Leitungen am Controller und sonstigen Komponenten Schlie en Sie den Server ste
33. rennt das Ger t nicht von der Netzspannung Zur vollst ndigen Trennung von der Netzspannung m ssen Sie die Netz stecker aus den geerdeten Schutzkontakt Steckdosen ziehen Options Guide RX600 S3 Wichtige Hinweise Sicherheitshinweise A ACHTUNG Schlie en Sie das Ger t und die daran angeschlossenen Peripherie ger te immer am selben Stromkreis an Anderenfalls droht Datenver lust wenn z B bei Netzausfall die Zentraleinheit noch l uft das Peri pherieger t z B ein Speichersubsystem aber ausgefallen ist Datenleitungen m ssen ber eine ausreichende Abschirmung verf gen F r die LAN Verkabelung gelten die Anforderungen gem EN 50173 und EN 50174 1 2 Als minimale Anforderung gilt die Verwen dung einer geschirmten LAN Leitung der Kategorie 5 f r 10 100 Mbps Ethernet bzw der Kategorie 5e f r Gigabit Ethernet Die Anfor derungen der Spezifikation ISO IEC 11801 sind zu ber cksichtigen Verlegen Sie die Leitungen so dass sie keine Gefahrenquelle Stol pergefahr bilden und nicht besch digt werden Beachten Sie beim Anschlie en des Ger tes die entsprechenden Hinweise in der Betriebsanleitung des Ger tes W hrend eines Gewitters d rfen Sie die Daten bertragungsleitungen weder anschlie en noch l sen Gefahr durch Blitzschlag Achten Sie darauf dass keine Gegenst nde z B Schmuckkettchen B roklammern usw oder Fl ssigkeiten in das Innere des Ger tes gelangen elektrischer Schlag Kurzsc
34. rung einer der Ecken siehe obige Grafik Dr cken Sie den Prozessor nicht mit Gewalt in den Sockel um eine Besch digung der Anschl sse pins bzw des Prozessors zu vermei den gt Positionieren Sie den neuen Prozessor ber dem Sockel und setzen Sie ihn durch vorsichtiges Dr cken in den Sockel ein 1 gt Verriegeln Sie den Prozessor im Sockel indem Sie den Sockelheber wieder in die urspr ngliche Position bringen 2 34 Options Guide RX600 S3 Prozessoren Weitere Prozessoren einbauen Prozessor K hlk rper einbauen N ACHTUNG Bauen Sie nie einen Prozessor ohne K hlk rper ein es droht die ber hitzung des Prozessors Dies f hrt zum Ausfall des Prozessors und der Systembaugruppe gt Setzen Sie den K hlk rper vorsichtig auf den Prozessor Achten Sie darauf dass die W rmeleitpaste an der Unterseite des K hlk rpers nicht besch digt wird CF Bt e er Bild 17 K hlk rper befestigen gt Befestigen Sie den K hlk rper mit vier Schrauben Ziehen Sie dabei zuerst zwei diagonal gegen berliegende Schrauben an danach die beiden ande ren Schrauben Options Guide RX600 S3 35 Weitere Prozessoren einbauen Prozessoren Zus tzliche VRM Module einbauen Bild 18 Zus tzlich einzubauende VRM Module F r die 3 und die 4 CPU ist jeweils ein separates Core VRM Modul A zu installieren F r Third Level Size Cache Prozessoren z B Tulsa muss ein zus t
35. sable Programmable Read Only Memory ESD ElectroStatic Discharge elektrostatische Entladung FAT File Allocation Table FPC Front Panel Controller FRU Field Replaceable Unit FSB Front Side Bus GAM Global Array Manager GUI Graphical User Interface HDD Hard Disk Drive HE H heneinheit Options Guide RX600 S3 73 Abk rzungen HSC Hot Swap Controller PC Inter Integrated Circuit 1 0 Input Output ICM Intelligent Chassis Management ID Identification IDE Integrated Drive Electronics IEC International Electrotechnical Commission IME Integrated Mirroring Enhanced IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface IRQ Interrupt Request Line LAN Local Area Network LBA Logical Block Address LCD Liquid Crystal Display 74 Options Guide RX600 S3 Abk rzungen LED LP LUN LVD LWL MRL MMF NMI NTFS Light Emitting Diode Low Profile Logical Unit Number Low Voltage Differential SCSI LichtWellenLeiter fiber optic cable Manual Retention Latch Multi Mode Faser Non Maskable Interrupt New Technology File System NVRAM Os PAM PCI PDA Non Volatile Random Access Memory Operating System Promise Array Management Peripheral Component Interconnect Prefailure Detection and Analysing Options Guide RX600 S3 75 Abk rzungen PDF Portable Data Format POST Power ON Self Test PS 2 Personal Sy
36. schlusskabel auf Systembaugruppe befestigen Stecken Sie das Anschlusskabel auf den Anschluss J1H1 auf der System baugruppe neben den Anschluss SCSI B Der Anschluss J1H1 ist mit einer kleinen Kunststoffabdeckung A versehen die zuvor entfernt werden muss Setzen Sie die Speicherboards bzw Speicherboard Blindeins tze wieder in die Einbaupl tze C und D ein Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben 68 Options Guide RX600 S3 12 Fertigstellung T ACHTUNG Beachten Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff 12 1 Server schlie en ON a Bild 48 Geh useabdeckung montieren gt Positionieren Sie die Geh useabdeckung so dass an der R ckseite ca 1 2 cm berstehen siehe Kreis gt Schieben Sie die Geh useabdeckung bis zum Anschlag nach vorn Befestigen Sie die Geh useabdeckung mit den beiden unverlierbaren Schrauben an der Ger tevorderseite siehe Seite 24 Setzen Sie den Server in den Rackschrank ein Das Einsetzen in den Rackschrank ist in der Betriebsanleitung beschrieben gt Fixieren Sie den Server mit den R ndelschrauben im Rackschrank Stecken Sie alle Netzstecker in die Schutzkontakt Steckdosen und schalten Sie den Server ein Options Guide RX600 S3 69
37. stem 2 RAID Redundant Arrays of Independent Disks RAM Random Access Memory RoHS Restriction of the Use of Certain Hazardous Substances Waste from Electric and Electronic Equipment EU Richtlinie ROM Read Only Memory RoMB RAID on Mother Board RSB Remote Service Board RTC Real Time Clock RTDS Remote Test und Diagnose System SAF TE SCSI Accessed Fault Tolerance Enclosures SATA Serial Advanced Technology Attachment SBE Single Bit Error 76 Options Guide RX600 S3 Abk rzungen SCA Single Connector Attachment SCSI Small Computer System Interface SCU System Configuration Utility SDR Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory SEL System Event Log S M A R T Self Monitoring Analysis and Reporting Technology SMI System Management Interrupt SSU System Setup Utility SVGA Super Video Graphics Adapter USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module Options Guide RX600 S3 77 Abk rzungen WEEE Waste from Electric and Electronic Equipment EU Richtlinie WOL Wakeup on LAN ZCR Zero Channel RAID 78 Options Guide RX600 S3 Literatur Handb cher f r PRIMERGY Serversysteme sind als PDF Dateien auf der ServerBooks CD verf gbar Die ServerBooks CD ist Teil der PRIMERGY ServerView Suite die mit jedem Serversystem ausgeliefert wird Die aktuellen Versionen der
38. technischem Fachpersonal durch gef hrt werden e Lassen Sie Reparaturen am Ger t nur von Fachpersonal durchf hren e Durch Nichtbeachtung der Vorgaben in diesem Handbuch sowie unbefugtes ffnen und unsachgem e Reparaturen k nnen Gefah ren f r den Benutzer elektrischer Schlag Brandgefahr bzw Sach sch den am Ger t entstehen e Unerlaubtes ffnen des Ger tes hat den Garantieverlust und den Haftungsausschluss zur Folge Machen Sie sich bitte zu allererst mit den Sicherheitshinweisen im Kapitel Wichtige Hinweise auf Seite 13ff vertraut gt Stellen Sie sicher dass alle ben tigten Handb cher siehe Zus tzliche Dokumentation des Servers auf Seite 6 zur Verf gung stehen drucken Sie eventuell die PDF Dateien aus Sie ben tigen auf jeden Fall die Betriebsanleitung des Servers das Service Supplement und das Technische Handbuch der Systembaugruppe Fahren Sie den Server ordnungsgem herunter schalten Sie ihn aus zie hen Sie die Netzstecker und ffnen Sie den Server wie im Kapitel Vorberei tung auf Seite 23f beschrieben wird F hren Sie die Erweiterung oder Hochr stung Ihres Servers aus wie in dem betreffenden Kapitel beschrieben Der Ein Ausbau der hot plug Komponenten ist in der Betriebsanlei tung des Servers beschrieben Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapite
39. terungen Defekte am Ger t verursachen Stellen Sie nur die Bildschirmaufl sungen und Bildwiederholfrequen zen ein die in der Betriebsanleitung f r den Bildschirm angegeben sind Wenn Sie andere Werte einstellen kann der Bildschirm besch digt werden Wenden Sie sich im Zweifelsfall an Ihre Verkaufsstelle oder an unseren Service ACHTUNG e Bei unsachgem em Austausch von Batterien besteht Explosions gefahr Batterien d rfen nur durch identische oder vom Hersteller empfohlene Typen ersetzt werden siehe Technisches Handbuch zur Systembaugruppe im Abschnitt bersicht ber die Dokumentation auf Seite 5 Tauschen Sie die Lithium Batterie auf der Systembaugruppe nur ent sprechend den Angaben im Technischen Handbuch f r die System baugruppe siehe Abschnitt bersicht ber die Dokumentation auf Seite 5 Options Guide RX600 S3 Wichtige Hinweise Sicherheitshinweise Umgang mit CDs DVDs und CD DVD Laufwerken T ACHTUNG e Verwenden Sie im CD DVD ROM Laufwerk Ihres Servers aus schlie lich einwandfreie CDs um Datenverlust Besch digungen am Ger t und Verletzungen zu vermeiden e berpr fen Sie jede CD DVD vor dem Einlegen in das Laufwerk auf Besch digungen wie feine Risse Bruchstellen oder dergleichen Beachten Sie dass zus tzlich aufgebrachte Aufkleber die mechani schen Eigenschaften einer CD DVD ver ndern und zu Unwucht f h ren k nnen Besch digte und unwuchtige CDs DVDs k nnen
40. unterhalb der M lltonne angegeben Cd Cadmium Hg Quecksilber Pb Blei F r Deutschland gilt Private Verbraucher k nnen Batterien nach Gebrauch in der Verkaufsstelle oder in deren unmittelbaren N he unentgeltlich zur ckgeben Der Endverbraucher ist verpflichtet defekte oder verbrauchte Batterien an den Vertreiber oder an die daf r eingerichteten R cknahmestellen zur ck zugeben Ansprechpartner vor Ort Einzelheiten zur R cknahme und Verwertung der Ger te und Verbrauchsmate rialien im europ ischen Raum erfahren Sie ber Ihre Fujitsu Siemens Compu ters Gesch ftsstelle oder von unserem Recycling Zentrum in Paderborn Fujitsu Siemens Computers Recycling Center D 33106 Paderborn Tel 49 5251 8180 10 Fax 49 5251 8180 15 Internet www fujitsu siemens com recycling Options Guide RX600 S3 21 4 Vorbereitung ACHTUNG Beachten Sie die Sicherheitshinweise im Kapitel Wichtige Hinweise auf Seite 13ff Beenden Sie alle Anwendungen und fahren Sie den Server ordnungsgem herunter Falls Ihr Betriebssystem den Server nicht ausgeschaltet hat dr cken Sie die Ein Aus Taste Ziehen Sie alle Netzstecker aus den Schutzkontakt Steckdosen 4 1 Server ffnen Bild 4 Ausbau des Servers L sen Sie die R ndelschrauben 1 und ziehen Sie den Server vorsichtig bis zum Anschlag aus dem Rack 2 Options Guide RX600 S3 23 Server ffnen Vorbereitung gt I
41. ur Seite dr cken und schwen ken Sie ihn bis zum Anschlag nach oben 1 gt Heben Sie den eingebauten Prozessor vorsichtig aus dem Sockel 2 Neuen Prozessor einsetzen T ACHTUNG Der Prozessor kann nur in einer Richtung eingebaut werden Achten Sie dabei auf die Markierung einer der Ecken siehe obige Grafik Dr cken Sie den Prozessor nicht mit Gewalt in den Sockel um eine Besch digung der Anschl sse pins oder des Prozessors zu vermei den Bild 25 Neuen Prozessor einsetzen gt Positionieren Sie den neuen Prozessor ber dem Sockel und setzen Sie ihn durch vorsichtiges Dr cken in den Sockel ein 1 gt Verriegeln Sie den Prozessor im Sockel indem Sie den Sockelheber wieder in die urspr ngliche Position bringen 2 42 Options Guide RX600 S3 Prozessoren Prozessor austauschen gt Setzen Sie den K hlk rper vorsichtig auf den Prozessor Achten Sie darauf dass die W rmeleitpaste an der Unterseite des K hlk rpers nicht besch digt wird Befestigen Sie den K hlk rper mit vier Schrauben siehe Seite 35 Ziehen Sie dabei zuerst 2 diagonal gegen berliegende Schrauben an danach die beiden anderen Schrauben gt Setzen Sie die Prozessorabdeckung wieder ein siehe Seite 40 Schlie en Sie den Server stecken Sie alle Netzstecker in die Schutz kontakt Steckdosen und schalten Sie den Server ein wie in Kapitel Fertig stellung auf Seite 69f beschrieben Options Guid
42. z liches Cache VRM Modul VRM 9DO B gemeinsam f r die 3 und 4 CPU eingebaut werden 36 Options Guide RX600 S3 Prozessoren Weitere Prozessoren einbauen A Bild 19 Luftleithaube f r das Core VRM Modul der 4 CPU e Die obige Luftleithaube muss vor dem Einbau des Core VRM Moduls der 4 CPU ausgebaut und anschlie end wieder eingesetzt werden Die Kunststoffnase A wird am Chassis Quersteg eingesteckt siehe Bild 21 auf Seite 39 Options Guide RX600 S3 37 Weitere Prozessoren einbauen Prozessoren les d Bild 20 Lage der zus tzlich einzubauenden VRM Module Stecken Sie die erforderlichen VRM Module in die jeweiligen Einbaupl tze das Core VRM Modul A1 f r die 3 CPU das Core VRM Modul A2 f r die 4 CPU das Cache VRM Modul VRM 9DO B f r die 3 und 4 CPU Das zus tzliche Cache VRM Modul wird nur f r Third Level Size Cache Prozessoren z B Tulsa ben tigt 38 Options Guide RX600 S3 Prozessoren Weitere Prozessoren einbauen gt Setzen Sie die Luftleithaube f r das Core VRM Modul der 4 CPU wie folgt ein F hren Sie die Kunststoffnase siehe Bild 19 auf Seite 37 in den Schlitz des Chassis Querstegs ein siehe Kreis in obiger Abb Schwenken Sie die Luftleithaube nach unten Options Guide RX600 S3 39 Weitere Prozessoren einbauen Prozessoren Prozessorabdeckung einsetzen Bild