Installation and Use – Please store this document securely
Contents
1. Installation and Use Please store this document securely Security advice Please read this manual carefully and completely it contains useful and important information on the function maintenance placement and installation of this detector Reliable operation can only be guaranteed if the instructions are followed correctly Please check the installation location carefully in advance in case there are any electrical installations behind the wall or above the ceiling In case of alarm a very loud sound is emitted Do not switch the unit on in close proximity to anybodies ears Keep away from children This smoke detector is a photo electric sensor with integrated relays to connect to any alarm control system such as the RMS When smoke is detected a loud siren is sounded and the relay is activated Smoke detection works using scattered light technology which is highly sensitive to any fire especially smouldering fire The integrated heat sensor activates the alarm at approximately 70 85 C An automatic self test is performed regularly and any malfunction is shown by the integrated LED Supplied Contents Smoke detector 2 screws mounting plate 4m cable this manual Technical Data Operating voltage 12 V DC or AC 15 Operating temperature 0 C 55 C Smoke sensor scattered light principle Heat sensor alarm 70 C 85 C Life time 10 years maximum Typical current 2mA Alarm current approx 25mA Humidity 25 75 relati
2. Loch und befestigen Sie das Geh use R ckenteil gegebenenfalls mit den mitgelieferten Schrauben an den Winkel Schlie en Sie die Verdrahtung an der Alarmzentrale RMS wie folgt an Die blaue Anschlussklemmleiste ist von der Platine trennbar abziehen um das Anschlie en zu erleichtern U U Stromversorgung 11 15 Volt AC oder DC REL REL Ausgangs Relaiskontakte Testknopf mit LED Durch die Stellung der Br cke K4 wird die Kontaktart auf NO Schliesser bzw NC Offner eingestellt Durch die Br cke K5 wird die Kontaktart der Relais eingestellt Ist die Br cke K5 auf ON eingestellt wird der Warnton und das Relais bis zu einer kurzen Unterbrechung der Stromzufuhr aktiviert Dies ist f r die Lokalisierung der Alarmquelle n tzlich Ist die Br cke K5 auf OFF eingestellt so stellen sich der Warnton und das Relais automatisch zur ck wenn sich die Rauchdichte wieder abbaut Schlie en Sie die Anschlussklemmleiste wieder auf der der Platine an Dr cken Sie das Vorderteil auf das R ckenteil des Geh uses so dass beide Befestigungslaschen einrasten Schalten Sie die Stromversorgung ein Der Melder erzeugt einen Piepton um die Bereitschaft zu signalisieren Halten Sie die Testtaste gedr ckt Es ert nt ein lauter pulsierender Warnton und nach einigen Sekunden schaltet das Relais Betrieb Bei normalem Betrieb wird alle 40 Sekunden ein Selbsttest vorgenommen Dies wird durch ein kurzes Blinken der LED signalisiert Wi
3. caused i e workshops barns Installation 1 This smoke detector should only be powered from an appropriate regulated power supply Follow your local installation guidelines and legal instructions Protect the smoke detector from dirt and dust 2 Drill a hole for the cable through the back of the detector Guide the cable through the hole and fix it to the mounting plate or ceiling Connect the cable to your alarm system the RMS as follows Test button ith LED The blue contact strip can be pulled off the PCB for easy connection of the cables U U Power supply 11 15 Volt AC or DC REL REL Output relay contacts The jumper contacts K4 sets the detector function as NO normally open contact or NC normally closed contact The jumper contacts K5 set the contact function of the relay K5 ON gt the alarm and the relay are activated for a short time until the supply voltage is interrupted This helps to localize the detector that has caused the alarm K5 OF F gt the alarm and relay is self reset as soon as the smoke density goes back to normal 3 Finally put the contact strip back on to the PCB Put the cover back into its place and close it firmly so that both latches are engaged Switch on the supply voltage Now the detector should give one beep to indicate its operation state Next hold the LED test button down until a loud pulsating warning tone is emitted and the relay is activated Operation Under
4. hat einen foto elektronischen Sensor und einen Relaisausgang zum Anschluss an den digitalen Eingang des RMS Bei Raucherfassung ert nt ein lauter Warnton und das eingebaute Relais wird aktiviert Die Rauchentdeckung funktioniert nach dem Streulicht prinzip das besonders schnell auf Schwelbr nde reagiert Der integrierte Hitzesensor l st Alarm bei Temperaturen ber 70 85 C aus Eine automatische Selbstkontrolle wird regelm ig durchgef hrt und St rungen ber die Leuchtdiode gemeldet Lieferumfang Rauchmelder 2 Schrauben Montagewinkel 4m Anschlusskabel diese Anleitung Technische Daten Betriebsspannung 12 V DC oder AC 15 Ruhestrom 2mA Alarmstrom ca 25mA Temperaturbereich 0 55 C nur in geschlossenen R umen Luftfeuchtigkeitsbereich 25 75 rel Luftfeuchte nicht kondensierend Rauchsensor Streulichtprinzip Empfindlichkeit m 0 05 0 07dB m EN 54 7 Hitzesensor Alarmausl sung ca 70 C 85 C Eingebaute Sirene ca 85dB A 3m Lebensdauer 10 Jahre maximal Relais max 1A 120VAC max 2A 24VDC Erf llt EN54 7 und prEN ISO 12239 Normen Kabel ca 4m Gewicht ca 0 1kg Ma e ca 12 x 4cm Plazierung Rauchmelder sollten an der Decke m glichst in der Mitte des Raumes montiert werden Ein Mindestabstand von 60 cm zu W nden und anderen Gegenst nden sollten immer eingehalten werden Bei R umen mit Schr g Spitz oder Giebeldecken wo stehende Luft den Rauchaufstieg verhindern kann sollte der Rauchalarm ca 1 Me
5. ION SEP 2005 English Deutsch
6. communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced technician for help You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation For Commercial Use Tested to Comply with FCC Standards LINDY ELEKTRONIK GMBH FIRST EDITION SEP 2005 IND COMPUTER CONNECTION TECHNOLOGY Smoke amp Temperature Sensor Rauch amp Temperaturmelder User Manual Benutzerhandbuch I LINDY No 32435 www LINDY com For Commercial Use Tested to Comply with FCC Standards LINDY ELEKTRONIK GMBH FIRST EDIT
7. normal operation every 40 seconds a self test is performed This is indicated by a short LED flash As soon as the sensor detects smoke the alarm is activated siren and relays If K5 is set to OFF the alarm is reset as soon as the smoke density goes below the alarm level the detector is active again To test the detector manually hold down the test LED button until the alarm is sounded False Alarms When an alarm is activated check carefully for hidden fires To reset the alarm ventilate the room for a while and then switch off the supply voltage if K5 is set ON for a short time Use a vacuum cleaner to clean the detector Maintenance Use a dust or vacuum cleaner to clean the detector every 6 months The cover can be cleaned with a damp cloth Do not use any strong solvents Do not paint the detector Bedienungs und Montageanleitung Bitte sorgf ltig aufbewahren Sicherheitshinweise Bitte lesen Sie diese Anleitung vollstandig durch sie enthalt wichtige Informationen Uber Funktionen Montage Platzierung und Pflege dieses Produktes Eine zuverl ssige Fr hwarnung bei Brand und Rauchentwicklung ist nur gegeben wenn dieser Rauchmelder im Einklang mit dieser Anweisung verwendet wird berpr fen Sie die Montagestelle vor Bohrarbeiten auf unter Putz verlegte Leitungen Bei Alarm ert nt ein lauter pulsierender Warnton Die Sirene ist laut Nicht in direkter Ohrn he einschalten Halten Sie Kinder davon fern Der Rauchmelder
8. rd Rauch in der Messkammer gemeldet so wird Alarm ausgel st die Sirene ert nt und das Relais wird aktiviert Wenn die Rauchdichte sinkt wird der Alarmzustand automatisch zur ckgestellt angenommen die Speicherbr cke K5 steht auf OFF und der Melder ist wieder in Bereitschaft Um den Melder zu pr fen halten Sie die LED Taste gedr ckt bist die Sirene ert nt und das Relais aktiviert wird Fehlalarme Pr fen Sie bei jedem Alarm ob es irgendwo brennt Den Raum gut l ften bis der Alarmton abschaltet oder eventuell das Ger t mit dem Staubsauger absaugen Nach einem Alarm ist das Ger t automatisch wieder betriebsbereit Pflege Alle sechs Monate sollte das Ger t vorsichtig mit dem Staubsauger abgesaugt werden Der Deckel kann mit einem feuchten Tuch abgewischt werden Keine scharfen Reinigungsmittel verwenden Den Rauchmelder auf keinen Fall mit Farbe berstreichen Rauchmelder sollten alle f nf Jahre sp testens nach 10 Jahren ersetzt werden Radio Frequency Energy Certifications FCC Warning This equipment has been tested and found to comply with the limits for a Class B Digital device pursuant to part 15 ofthe FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio
9. ter vom h chsten Punkt montiert werden z In langen G ngen sollten Rauchmelder nicht mehr als 8m auseinander nicht mehr als 4m vom Gangende und nicht mehr als 7m von jeder T r montiert werden a Als Faustregel Ein Rauchmelder kann einen Raum von ca 50m ohne Trennung berwachen Folgende Stellen sind nicht geeignet An der Wand oder in der N he von T ren Fenstern Heizk rpern Ventilatoren in Treppenh usern etc wo Luftz ge entstehenden Rauch ablenken k nnen In Bereichen in denen die Temperatur des Ofteren unter 4 C f llt oder ber 40 C steigt In Bereichen mit erh hter Luftfeuchtigkeit z B im Badezimmer In kleinen oder schlecht gel fteten Garagen und K chen k nnen Abgase und D mpfe Fehlalarme ausl sen An Stellen an denen Sie den Rauchmelder zum Funktionstest schlecht erreichen In der N he von Leuchtstoffr hren mindestens 50cm Abstand einhalten oder stromf hrenden Leitungen oder in Bereichen in denen ein erh htes Niveau an Elektrosmog herrscht In Bereichen in denen starker Staub oder Schmutzanfall die Funktion beeintr chtigt oder Fehlalarme ausl sen k nnten z B Werkst tten oder Scheunen Montage und Installation Dieser Melder sollte nur an eine geeignete geregelte Stromquelle angeschlossen werden VDE und Bauvorschriften beachten Vor Staub sch tzen Bohren Sie gegebenenfalls ein Loch f r die Kabeldurchf hrung durch das Geh use R ckenteil Ziehen Sie das Kabel durch das
10. ve humidity non condensing for indoor use Sensitivity m 0 05 0 07dB m EN 54 7 Alarm siren 85dB A 3m Relay max 1A 120VAC max 2A 24VDC Conformity EN54 7 and prEN ISO 12239 Cable 4m Weight 0 1kg Dimensions 12 x 4cm Placement The Smoke sensor should be mounted on the ceiling if possible in the centre of the ceiling A minimum distance of 60cm to any wall or other equipment should be kept In rooms with non horizontal ceilings the sensor should be placed approximately 1m off the highest point In long corridors or rooms the smoke sensor should not be more than 4m away from any wall and should not be spaced more than 8m apart As a rule of thumb One smoke detector can cover a room of 50m approx The following locations are not suitable and should not be used Near a wall window door heating or ventilation device in stair cases or in any place with constant air flow Any area where the temperature often falls below 4 C or increases over 40 C In any area with high relative humidity for instance bathrooms In small or poorly ventilated garages kitchens or similar otherwise false alarms may be caused by exhaust gases and steam Any place where the self test LED button cannot be reached Close to fluorescent lamps keep a minimum distance of 50cm or close to cables or any area with a high degree of electrical interference In any rooms or areas with a high degree of dust or dirt otherwise false alarms can be