Samsung AR5500 Wall-mount AC with Faster Cooling, 12000 BTU/h User Manual

image

Contents

1. r Insert the Air filter back in its original position Dry the Air filter in a ventilated area Clean the Air filter every 2 weeks Cleaning term may differ depending on the usage and environmental NOTE conditions In dusty area clean it once a week Ifthe Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a well ventilated area English 26 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 26 D 2015 1 17 16 48 08 Reassembling the Air filter 1 Put the filter on the main body and insert the hooks which are in the top of the Air filter into the the main body O Air filter SDNILLIS 90 2 Theres one hook in both side of the filter press the surface of O the Air filter softly and get the hooks into the main body Y gt 3 Press the bottom of the filter lightly to securely fix the main body 9 English 27 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 27 D 2015 1 17 16 48 08 aa o Maintaining the air conditioner Ifthe air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1 Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut off
2. core yng f Diameter i Body cap N m Charging port cap mm Nem R 22 Diameter of the screw 7 16 20UNF R 410A Diameter of the screw 1 2 20UNF 6635 a 09 52 20 25 612 70 25 30 10 12 Tightening torque for charging port cap E Refer to the table 915 88 otis 019 05 35 40 To check for gas leaks on the outdoor unit 1 Nm 10 kgfecm Check the valve A and B using a leak detector To check for gas leaks on the indoor unit Check the flare nut C and D using a leak detector Leak test with nitrogen before opening valves In order to detect basic refrigerant leaks before recreating the vacuum and recirculating the R 410A it s responsible of installer to pressurize the whole system with nitrogen using a cylinder with pressure reducer at a pressure above 40 bar gauge Leak test with R 410A after opening valves Before opening valves discharge all the nitrogen from the system and create vacuum according to page 47 48 After opening valves check leaks using a leak detector for refrigerant Pump down before disconnecting the refrigerant connections for unit repair removal or disposal Pump down is an operation intended to collect all the system refrigerant in the outdoor unit This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere gt Shut off the liquid valve with the Allen wrench gt Turn the system on in cooli
3. Remote controller display Quiet function is only available in Cool mode If the Quiet function is selected while 2 Step Cooling Fast Comfort Single user good sleep function is on corresponding function will be cancelled English 22 NOTE 2015 1 17 16 48 05 o A Using the Single user function This function will reduce the energy usage while the air conditioner is operating in Cool mode When the air conditioner is operating in Cool mode 1 Press the Single user button Single user indicator will be displayed on the remote controller display Then __ willbe displayed on the set temperature indicator part for few seconds and Single user function will begin When the Single user function is on vertical air swing will turn on automatically Ifthe current set temperature is lower than 24 C in Cool mode it will be automatically raised to 24 C SNOILdO 0 Cancel Press the Single user button once again Single user function is only available in Cool mode NOTE If the Single user function is selected while 2 Step Cooling Fast Comfort Quiet good sleep function is on corresponding function will be cancelled Vertical air swing will remain on even after the Single user function is cancelled Select or cancel the Single User function with the Options button Press the Options button press the 2 or Options button to make Single user indicator blink
4. Display may be different depending on the model 3 Smart Install mode will end 1 Smart Install mode will take approximately 7 13 minutes Actual time may be different depending on the model 2 When Installation is successful Smart Install mode will end with ringing sound and the air conditioner will be in standby status Error message will not be displayed on the indoor unit indicator and the remote controller and buttons on the indoor unit will work normally 3 When installation is not successful Smart Install mode will end and error message will be displayed on the indoor unit display A CAUTION 1 Take necessary measures when error occurs Refer to the service manual for necessary measures for each error that occurs 2 Use the product after taking care of the error that occurs Error indicator Check the LED display on outdoor unit for the details For Inverter model only LED Display LED1 LED2 LED 3 Error Measures to take by an installer g g Display To ga DI Kai o2 0 OD pee Commnuication Error 1 Check the connection wire between indoor and EDI O O O between Indoor and outdoor unit whether the power cable and outdoor unit commnunication cable is crossed or not E aj Error on indoor 1 Check the connection of the connector et temperature sensor Error on indoor heat 1 Check the connection of the connector Cd E ic E 103 exchanger 1 C
5. Charge the refrigerant turning the cylinder cylinder upright i upside down IfR 410A refrigerant is charged with gas the composition of the charged refrigerant changes and the note Characteristics of the equipment vary During the measuring operation of refrigerant quantity added use electronic scales If cylinder doesn t have syphon upset it English 48 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 48 D 2015 1 17 16 48 24 aa o Performing the gas leak tests Make sure to check for gas leaks before completing the installation process connecting the assembly pipe and hose between indoor unit and outdoor unit insulating the cables hose and pipe and fixing the indoor unit to the installation plate o N E D Cal gt Z o z Test part for outdoor unit Test part for indoor unit Tightening torque for body cap Before inspecting the leakage use a torque wrench Refer to the table to close the cap for the service valve Comply with a Li tightening torque for each size of the diameter and JEX tighten the cap firmly to prevent any leakage gt To check for any possible leakage insert inert gas into TUY Spindle the pipes connected to indoor outdoor units and JIA check the connection part of the indoor outdoor units Charging E with soap lather or liquid for leakage test E Outer Tightening torque
6. Checkingthename of the paris tc 11 Ghecking the remote controller cotas RE des ide 12 Basic FUNCION s ne o lios a a da 14 Adjusting thelr Tow diECtiON ocioteca dida 16 Timer Setting the On Off timer 30km NGGA Sead sea E doe cba ANS kA AG 17 good sleep APAPAP AA PAA PAA PAPA AA 19 Options 2 Step cooling UNC rr ota tanto 20 Usingithe Fast UNCON usina tt 20 Using the Comfort functio sss ssion aeaa a ee id 21 Using the Virus Doctor functio a aaa aa ASES 21 UsingiheQuiettunciO rr ia TE EEEE aba E 22 Usingithe Single UsErtuncii n a tio A E GANON 23 Settings Wsinig the Auto cleanitunCtion consta ticino aras 24 Setting the Beep SOUNG tii ei 24 Others Cleaning theair conde irte o 25 Maintainingthe ait conditiONer iisiio nn GAAN ANG NG PARTE RARA rei gra Races 28 Troubleshooting esos jarra KATAD ALENA NANGANAK AGA si 29 Installation Safety precaria ri 31 Choosingithe installation locations rao eraa id EE AOTEA 32 ACC SSOMOS cuina tii ai 35 Fixing the installation plate emnin nian toa ica irracional dela iran 37 Disassembling Assembling the Cover panel for indoor unit installation ooocccccoccccccnccnccnncnnonccnnrnnnnnos 38 Connecting the assembly cable a NANA ri 40 Installing and connecting the assembly pipe of the indoor unit 0 eee e cence eee eee eee eee eeeeneeeeenaenaees 42 Evacuating thelindGor Unit es Babasa dana ha NG AGA ose NAA 43 Cuttind orextending he pisar DAANAN Nha a BANANA BAT ini
7. Therefore before fixing the installation plate to a wall or a window frame you must determine the position of the 65 mm hole through which the cable pipe and hose pass to connect the indoor unit to the outdoor unit When facing the wall the pipe and cable can be connected from the Right A Direction of pipe Left B Underside_right C Rear_right or left D NOILVTIVISNI ZO 1 Disassemble the cover panel as described in page 38 39 2 Remove the Hanger plate from the indoor unit 1 Unscrew 2 screws that fixes the Hanger plate to the indoor unit 2 Push the hooks on the bottom part of the indoor unit up to release the installation plate from the hooks that holds it 3 Pull the installation plate to release it completely from the indoor unit 3 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards Pipe hole 065 mm _Pipe hole 065 mm 7 FE IT rk ft FE Unit mm Model A B Cc D f Make sure to drill only one hole after choosing KX09 12XX 36 120 81 36 CAUTION the direction of the pipe XA18 24X 33 110 110 33 4 Fix the indoor unit If you fix the indoor unit on a wall Y 1
8. 43 Installing and connecting the drain hose of the indoor unit 0 45 Changing directiomof the drain NOSC 5 ii Nina APANG AA KANAN NG NG NAA AN LANANG 46 Evactiating the connected pipes iii ANA NA aNG 47 Performing the gasleaktESS ii polainas 49 Fixing the indoor unitin pagaani Gma ada RR 50 Fixing theoutdoonunit in plage 3352333 RR MAIA NENG KG KATAD EL ABANGAN series dana poca bad 50 SUOI SRO NN RARA 51 Final check anditrial operationi a isa NN NG NAKADALE ARALAN GAGA 53 Pump down procedure when removing the product LL 53 How to connect your extended power cables Lv 54 English 3 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 3 D 2015 1 17 16 47 53 Safety precautions Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com Important safety symbols and precautions Hazards or unsafe practices that may result in severe A WARNING personal injury or death Hazards or unsafe practices that may result in minor A CAUTION personal
9. 602 310 HA24XX 660 340 Y Designed to cut off residual vibration from outdoor unit to rack not supplied with product 2015 1 17 16 48 24 aaa A Smart Install mode This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions Execute Smart Install mode after installation 1 Check the installation status of the air conditioner 1 Check the power supply service valve if it s open power cable of the indoor and outdoor unit and amount of additional refrigerant required for pipe extension 2 Status of the indicator after supplying the power Standby status 2 When the air conditioner is in standby status use the remote controller to start the Smart Install mode 1 Press the SET Mode Power button simultaneously for 4 seconds NOILVTIVISNI ZO Remote controller may be different image functions depending on the model English 51 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 51 D 2015 1 17 16 48 27 Smart Install mode 2 Smart Install mode in progress 88 Display Progress will be diplayed in 0 99 LED Display Indicator on the indoor unit display will blink in sequence and then all indicators will blink This will be repeated TYPE 88 Display LED Display i a aaa a bA O ie Indoor unit indicator Lt Ll O i LED2 om aa O LED3 dd ll TF
10. Cancel the selected option or Directional lt gt setting Move through the Timer Options or Settings menu to make a selection In case you wish to cancel the options or settings that you have just set press the Options or Settings button again NOTE then the most recently selected item will blink and you may simply cancel it by pressing the SET button while selected item is blinking English 12 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 12 D 2015 1 17 16 47 55 I Remote controller display Transmit indicator Operation mode indicator Low battery indicator Set temperature Time for Timer option indicator Fan speed indicator good sleep indicator Vertical air swing indicator NOILINNIJISYA ZO Options indicator F light Cool Usage 0 Bas Settings indicator Filter Reset Bienia Make sure that the water does not get to the remote controller caution Heat mode and the following function are displayed on the remote controller display but not supported in this model d light Cool Usage Filter Reset Display When turning off and turning on the remote controller the Timer Options and Settings set before turning off the remote controller are cancelled However the fan direction does not change Low Battery warning Inserting the batteries When the battery is exhausted 24 will be displayed in the 1 Push the lever as arrow indicates on the rear side of th
11. D 2015 1 17 16 47 54 o A Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model I Main parts Air filter T Air intake NOILINNIDISVA ZO Air flow blade up and down Air flow blade left and right Power indicator Timer Auto clean indicator Power button Virus D indi Remote controller receiver irus Doctor indicator English 11 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 11 D 2015 1 17 16 47 55 o A Checking the remote controller Point the remote controller towards the remote controller receiver of the indoor unit When you properly press the button on the remote controller you will hear beep sound from the indoor unit and a transmit indicator gt appears on the remote controller display Remote controller buttons Vertical air swing Activate Deactivate vertical air flow blade movement automatically Mode Set one of the 4 operating modes Power Turn on off the air conditioner Fana Y Adjust the fan speed Temp Increase Decrease the temperature by 1 C Single User Turn on off the Single User function which reduces energy usage while operating in cool mode Options Select options during operation Timer Select Timer option Settings Select settings SET Set
12. Fix the installation plate to the wall giving attention to the weight of the indoor unit Plastic Ifyou mount the plate to a concrete wall using plastic anchors make sure that gaps Anchor Note between the wall and the plate created by projected anchor is less than 20 mm lt 20 mm PA If you fix the indoor unit on a window frame 1 Determine the positions of the wooden uprights to be attached to the window frame 2 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit 3 Attach the installation plate to the wooden upright using tapping screws If you fix the indoor unit on a gypsum board 1 Use stud finder to find out locations of the studs 2 Fix the plate hanger on two studs English 37 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 37 D 2015 1 17 16 54 58 Fixing the installation plate Search for other spots if there are less than two studs or the distance between the studs are different from the caumon Plate hanger Fixthe installation plate without inclining to one side Make sure that a wall can withstand the weight of the product If you install the product in a place where it is not warning Strong enough to withstand the product weight the unit could fall and cause injury I Assembling the hanger screw Use 2 screws to fix the indoor unit with hanger plate as shown in the picture Please scan this QR code for detail video of indoor unit in
13. IM_DB68 05272A_EN indd 31 D 2015 1 17 16 48 09 aaa A Safety precautions gt After completing the installation always carry out a functional test and provide the instructions on how to operate the air conditioner to the user gt Donotuse the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires explosions or injuries To help prevent injury when accidentally touching the indoor unit fan install the indoor unit at least 2 5 m above the floor gt The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry gt Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation won t be considered in warranty and charged to end user Power supply line fuse or circuit breaker gt Always make sure that the power supply is compliant
14. Space Requirements for Outdoor Unit When installing 1 outdoor unit Figure Description Top view Side view Air intake Air outlet 4 Air intake Air outlet lati el Air flow direction i Unit mm When the air outlet is opposite the When the air outlet is towards the When 3 sides of the outdoor unit are wall wall blocked by the wall o LESLIE N y gt g o U y i B i 5 9 5 i gs D y KB a 150 or more 600 or more 4 The upper part of the outdoor unit 4 The upper part of the outdoor unit 4 When the walls are blocking front and the air outlet is towards the wall and the air outlet is opposite the and the rear side ofthe outdoor unit wall NEA Poro E L9 6 2000 or more 5 ARE NS o D a 8 _ n a 1500 or more on When installing more than 1 outdoor unit Unit mm 4 When the air outlet is towards the wall 4 When 3 sides of the outdoor unit are blocked by the wall U U U g o E E o o 2 5 y UV y Jo tg o la gt gt t 300 or more 600 or more 600ormore 600 or more English 34 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 34 D 2015 1 17 16 48 10 A mi pa Unit mm 4 When the walls are blocking front and the rear side of the outdoor When the upper part of the outdoor unit and units the air outlet is opposite the wall y a A tt U 600 or more a 4 4 300 or more 500 or
15. indicator and the set time of the good sleep mode will be displayed on the remote controller display Timer indicator will be displayed on the indoor unit display good sleep mode setting will be cancelled if you don t press the SET button within 10 seconds after setting the time Therefore check for the ES indicator on the remote controller display and the Timer indicator on the indoor unit display gt Press the Timer button select 29 press the CJ or button set the timer to LLLI gt press the SET button Cancel Remote controller display Additional options available in good sleep mode You can adjust the set temperature by 1 C within the range of 16 C 30 C When the good sleep mode is on In Cool mode Air flow direction will be adjusted automatically Temperature and fan speed change ingood sleep mode Fall asleep Eases you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up Allows you to wake up from comfortable intermittent air and it makes you feel refreshed Recommended set temperature is between 25 C 27 C for cooling If the set temperature is too low you may feel cold during sleep or catch a cold Optimal operation hour of good sleep mode is 8 hours Therefore if the time is set too short or long you may not feel as comfortable as you would expect If the good sleep m
16. the air and it makes the pressure inside of the refrigerant cycle abnormally high It may cause explosion and injury 1 Connect each assembly pipe to the appropriate valve on the outdoor unitand Outdoorunit 4 Indoor unit tighten the flare nut Gas pipe side 2 Tighten the flare nut first with your hands and then with a torque wrench Liquid pipe side applying the following torque 7 9 El Excessive torque can be cause of gas leakage Outer Torque Diameter Nem kgfecm Make the electrical connection and leave the system into stand by mode Do not turn on the system 96 35 mm 14 18 140 180 09 52mm 34 42 350 430 This is necessary for better vacuum operation full OPEN position of Electronic Expansion Valve EEV 612 70mm 49 61 500 620 015 88 mm 68 82 690 830 3 Connect the charging hose of the low pressure side of manifold gauge to a n Manifold gauge gas service port as seen in the picture N 4 Open the valve of the low pressure side of manifold gauge counterclockwise Valve 5 Evacuate the air in the connected pipes using the vacuum pump for about 15 minutes Gas service port gt Make sure that pressure gauge shows 0 1 MPa 76 cmHg after about pese 10 minutes This procedure is very important to avoid a gas leak gt Close the valve of the low pressure side of manifold gauge clockwise Turn off the vacuum p
17. to IEC standard for safety and current is measured according to ISO standard for energy efficiency Q Donotstandontopofthe appliance or place objects such as laundry lighted candles lighted cigarettes dishes chemicals metal objects etc on the appliance gt This may result in electric shock fire problems with the product or injury Do not operate the appliance with wet hands B This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance gt As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not drink the water from the air conditioner gt The water may be harmful to humans Do not apply a strong impact to the remote controller and do not disassemble the remote controller Do not touch the pipes connected with the product B This may result in burns or inju ry Do not use this air conditioner to preserve precision equipment food animals plants or cosmetics or for any other unusual purposes P This may result in property damage Avoid directly exposing humans animals or plants from the air flow from the air conditioner for long periods of time B This may result in harm to humans animals or plants A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 8 English 8 2015 1 17 16 47 54 aaa Cia NG This appliance is not intended for use by pers
18. 17 D 2015 1 17 16 47 58 Setting the On Off timer Setting the Off timer When the air conditioner is on 1 Press the Timer to select Off Off indicator will keep blinking and you can set the time 2 Pressthe button to set the time You can set the time in half hour unit from 30 minutes 0 5 on the display 3 hours and hour unit from 3 24 hours Time can be set from minimum 30 minutes to maximum 24 hours 3 Press the SET button to complete the Off timer setting Off indicator and the set time of the timer will be displayed on the remote controller display and the Timer indicator 3 will be displayed on the indoor unit display Off timer setting will be cancelled if you don t press the SET button within 10 seconds after setting the time Therefore check for the Off indicator on the remote controller display and the Timer indicator 3 on the indoor unit display gt Press the Timer button select Off press the EJ or button gt Cancel set the timer to 88 gt press the SET button gt Press the Power button Off timer may not work depending on the On Off status of the indoor unit Remote controller display and the On Off status of the indicator on the remote controller display Only the latest setting timer will be applied between the On Timer Off Timer and good sleep Off timer functions After setting the timer the set time will be displayed for 3 seconds before
19. A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 1 2015 1 17 16 47 53 A A Features of your new air conditioner 2 step cooling 2 step cooling function will quickly cool the room to reach the set temperature and then it will adjust the fan speed and air flow direction automatically to help you stay comfortable and refreshing I Fast cooling Ifyou want the strong and cool air just select Fast function It will get you the strongest air Comfort cooling Ifyou want the comfortable and refreshing air Comfort function will spread the cool air indirectly to you so that you can stay comfortable Single User Use Single User function when you are alone at home Single User function will minimize the energy consumption with inverter technology and reduce your electricity bill by adjusting the maximum operating capacity ofthe compressor I Easy Filter There is no grille to remove before separating the filter from the air conditioner Therefore filter can be cleaned easily more frequently Frequent filter cleaning will prevent dust from entering into the product or accumulating on the filter good sleep function good sleep function will allow you to have deep good night s sleep by adjusting the temperature fan speed and air flow direction I Smart Install When the installation is done your product will examine itself through trial operation to check if it was installed properly I Easy Install
20. ARAGUA 001 800 5077267 www samsung com latin_en support English 800 7267 www samsung com latin support Spanish PANAMA 800 0101 www samsung com latin_en support English 800 629 www samsung com latin support Spanish PUERTO RICO 1 800 682 5160 www samsung com latin_en support English TRINIDAD enn E www samsung com latin support Spanish 8 TOBAGO 1 800 SAMSUNG 726 7864 www samsung com latin_en support English Venezuela 0 800 SAMSUNG 726 7864 www samsung com ve support Bogot 600 12 72 COLOMBIA Gratis desde cualquier parte del pa s 01 8000 www samsung com co support 1121120 desde su celular SAM 726 CHILE AA www samsung com cl support BOLIVIA DIP 4628500 www samsung com cl support PERU 0 800 777 08 www samsung com pe support ARGENTINE 0800 333 3733 www samsung com ar support 405 437 www samsung com latin support Spanish URUGUAY 000 405 437 33 www samsung com latin_en support English 9 549 www samsung com latin support Spanish PARAGUAY 009 800 542 0001 www samsung com latin_en support English A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 56 DB68 05272A 2015 3 21 10 12 02 ARX HVSS Series 100 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product DEL A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 57 D 2015 1 17 16 48 31
21. C HO5VV F IEC 60245 IEC 66 CENELEC HO7RN F IEC 60245 IEC 57 CENELEC HO5RN F Connecting the cable Electrical work 1 For electrical and earth works comply with the technical standards of electrical installations and the the wiring regulations of the Local wiring regulations 2 Tighten the terminal block screw to 1 2 1 8 Nem 12 18 kgf cm 3 Precautions when connecting terminal blocks of the indoor unit gt Before connecting make sure the connecting part of the terminal socket is facing upwards Upside down The terminal There is no ring terminalto N socketis damaged cover the wire b There must be no space between the terminal and the screw when connected Any remaining space may become a fire hazard due to overheating of the electrical contact p Either the screw is not fitted roperly or there is a space The terminal socket between the screw and the is upside down L ring terminal A For the terminal block wiring use a wire with a ring terminal socket only Regular wires without a ring terminal socket may become a fire hazard due to overheating of the electrical CAUTION contact during a wiring work k When you install the unit make first refrigerant connections and then electrical connections Connect the air conditioner to grounding system before performing the electrical connection If unit is uninstalled first disconnect electrical cables then refrigerant connections
22. For more detailed information see the installation part in the manual English 28 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 28 D 2015 1 17 16 48 09 aa mb Troubleshooting Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner Check power status and then operate the air conditioner again does not workatall Plugin or switch on the circuit breaker and then operate the air conditioner again Ensure Isolator is switch on Check if you have set the Off Timer Operate the air conditioner again by pressing the Power button SONILLAS 90 The temperature e Check if you have selected Fan Fast mode In these modes desired adjustment is not temperature is set to auto and you cannot adjust the temperature working Cool air does not e Check if the set temperature is higher during Cool mode than the come out of the air current temperature Press the Temp or button on the remote conditioner controller to change the set temperature Check if the Air filter is blocked by dirt If there is a lot of dust on the Air filter cooling performance may decrease Clean them frequently Check if the outdoor unit is covered or installed near the obstacle Take the cover off and take the obstacle away If the doors or windows are open it may cause bad cooling performance Close the doors and w
23. If the outdoor unit is more than 8 meters away from the indoor unit you must extend the cable The maximum length of the cable is 15 09 12 30 18 24 meters 1 Extendthe assembly cable if necessary Do not connect two or more different cables to extend the length It may cause fire CAUTION English 40 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 40 D 2015 1 17 16 48 20 2 Openthe cover panel 3 Removethe screw securing the connector cover 4 Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals Refer to the picture below B Each wire is labeled with the corresponding terminal number NOTE Pass the other end of the cable through the 65 mm hole in the wall Close the connector cover by tightening the screw carefully Close the cover panel Remove the terminal board cover on the side of the outdoor unit Connect the cables to the terminals as seen in the picture NOILVTIVISNI ZO o Na Uu B Each wire is labeled with the corresponding terminal number NOTE 09 12 18 244 Indoor unit Indoor unit UJAN Fi F2 Indoor unit Ground wire e Green Yellow SES ead 1 2N Fi F2 Ground wire Green Yellow HI Ground wire Green Yellow a Green Yellow Ba LIN Fi F2 GE ol
24. Outdoor unit E CS Outdoor unit Also circular terminal must be matched with screw size in terminal block caution After connecting the cables make sure terminal numbers on the indoor outdoor unit matches Please ensure that Power amp Communication cables are separated they must not be in the same cable 10 Connect the grounding conductor to the grounding terminals 11 Close the terminal board cover by tightening the screw carefully In Russia and Europe consult with the supply authority to determine the supply system impedance before installation Connect the wires firmly so that wires can not be pulled out easily If they are loose it could cause burn out of the wires Connect the wires according to color codes referring to the wiring diagram The power cable and the interconnection cable should be selected according to the specification in page 40 English 41 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 41 D 2015 1 17 16 48 21 L o Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field supplied copper pipes by means of flare connections Use insulated seamless refrigeration grade pipe only Cu DHP type according to 1501337 degreased and deoxidized suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa Un
25. RNING When the circuit breaker is damaged contact your nearest service center Do not pull or excessively bend the power line Do not twist or tie the power line Do not hook the power line over a metal object place a heavy object on the power line insert the power line between objects or push the power line into the space behind the appliance B This may result in electric shock or fire English 5 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 5 D 2015 1 17 16 47 53 Safety precautions FORPOWER SUPPLY A CAUTION When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker B Failing to do so may result in electric shock or fire FOR USING 4 WARNING O ifthe appliance is flooded please contact your nearest service center P Failing to do so may result in electric shock or fire If the appliance generates a strange noise a burning smell or smoke cut off the power supply immediately and contact the nearest service center P Failing to do so may result in electric shock or fire In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power line Do not touch the appliance or power line gt Do not usea ventilating fan B A spark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center gt Failing to do so may
26. The heat may be caused by the excessive lighting or equipment that is turned on unnecessarily You should reduce heat in the air conditioned area English 9 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 9 2015 3 21 10 08 05 Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use Indoor Outdoor Ex Mode temperature temperature Indoor humidity Cooling 16 C 32 C 16 C 46 C Relative humidity 80 or less Dry 18 C 32 C 16 C 46 C gt If the air conditioner operates in cooling mode for long period of time in high humidity area dew may be formed I Maintaining your air conditioner Internal protections via the unit control system gt This internal protection operates if an internal fault occurs in the air conditioner Type Description The air conditioner does not start operating immediately to help protect the compressor Protect compressor k of the outdoor unit after it has been started I Smart install gt Through Smart install function installer can check if the installation was done properly gt Ifthe installation was not done properly error indicator will turn on the indoor unit display Therefore user will know if the installation was done properly or not English 10 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 10
27. When the operation mode is set during Auto clean function is activated the air conditioner will operate in chosen operation mode and the Auto clean function will be re activated when the operation stops During the auto clean function indoor fan will continue to run and air flow blade will remain open to expel ambient air Setting the Beep sound Beep sound from the indoor unit can be muted 1 Press the Settings button 2 Press the CI or Settings button until Beep indicator starts to blink 3 Press the SET button to mute the beep sound 3 seconds after setting Beep sound function Beep indicator on the remote controller display will disappear and Beep sound function will begin English 24 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 24 D 2015 1 17 16 48 07 o A Cleaning the air conditioner Make sure to turn off the power of the indoor unit and cut off CAUTION the power supply before cleaning the air conditioner I Cleaning the indoor unit gt Clean the product with a tepid damp cloth gt Remove the dust accumulated in the gap of the product with a soft brush SHIHLO 90 Contact the service center when you clean the indoor unit note heat exchanger because it needs to be disassembled Do not clean the display using alkaline detergent CAUTION Do not use sulfuric acid hydrochloric acid organic solvents such as th
28. ace in order to be able to use it as reference after installation For maximum safety installers should always carefully read the following warnings Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred This manual explains how to install an indoor unit with a split system with two SAMSUNG units The use of other types of units with different control systems may damage the units and invalidate the warranty The manufacturer shall not be responsible for damages arising from the use of non compliant units The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the Operating limits table included in the manual shall immediately invalidate the warranty The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Do not use the units if damaged If problems occur switch the unit off and disconnect it from the power supply In order to help prevent electric shocks fires or injuries always stop the unit disable the protection switch and contact SAMSUNG technical support if the unit produces smoke if the power cable is hot or damaged or if the unit is very noisy Always remember to inspect the unit electric connections refrig
29. air flow gt To keep the air flow direction in a constant direction press the button again The air flow blade s will stop the movement gt Ifyou adjust the vertical air flow blade manually it may not close completely when you turn off the air conditioner Adjusting the air flow direction is not available in NOTE good sleep mode while it is in cool mode Auto Set UND c a Remote controller display I Horizontal air flow Move the blade pin lever left or right to keep the air flow direction in a constant position you prefer To avoid the risk of personal injuries adjusting the horizontal air flow caution direction should only be done when the unit is turned off completely There is a potential risk of personal injury when the unit is mishandled English 16 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 16 D 2015 1 17 16 47 58 Setting the On Off timer Setting the On timer When the air conditioner is off 1 Press the Timer button to select On On indicator will keep blinking and you can set the time 2 Pressthe button to set the time You can set the time in half hour unit from 30 minutes 0 5 on the display 3 hours and hour unit from 3 24 hours Time can be set from minimum 30 minutes to maximum 24 hours 3 Press the SET button to complete the On timer setting On indicator and the set time of the timer will be displayed on the remote controller di
30. and press the SET button Single user Remote controller display Additional options available in Single user function Temp You can adjust the set temperature by 1 C within the range of 24 C 30 C in Cool mode N E Auto Low Med High 2p Turbo can be selected Vertical air swing can be selected English 23 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 23 D 2015 1 17 16 48 06 o A Using the Auto clean function Auto clean function will minimise the moisture inside of the indoor unit Activate this function to help provide you with clean air When the air conditioner is operating 1 Press the Settings button 2 Press the C or Settings button until Clean indicator starts to blink 3 Press the SET button to set the Auto clean function 3 seconds after setting Auto clean function Clean indicator on the remote controller display will disappear and Timer indicator will turn on the indoor unit display Auto clean function will be activated after the air conditioner stops operating Duration of the Auto clean function can be different depending on the previous operation mode used Auto cool Cool Dry mode 30 minutes Fan mode 15 minutes gt Press the Settings button Press the CJ C or Settings button to C I SE make the Clean indicator blink and press the SET button Indoor unit displa 5 i x NIA A and
31. ation It s so easy to install You can easily hang the product on the wall and connect the pipes and wires by opening the cover on the bottom of the product Now you won t have to tilt the product to connect the pipe and the wires Correct Disposal of This Product Waste Electrical 8 Electronic Equipment Applicable in countries with separate collection systems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal English 2 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 2 D 2015 1 17 16 47 53 aaa A Contents Preparation NG PAPUA 4 Checking beforelUse oral sidonia 10 Basic function
32. ble is optional If it is not supplied use the standard cable The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below I Optional accessories The following connection accessories are optional If they are not supplied you should obtain them before installing the air conditioner B If these accessories are supplied they will be in the accessory box NOTE Tools required for installation General Tools e Vacuum Pump Backward flowing prevention Manifold Gauge Stud Finder Torque Wrench Pipe Cutter Reamer Pipe Bender Spirit Level Screw Driver Spanner Drill LWrench Measuring Tape Tools for test operations Thermometer A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 36 Resistance Meter Electroscope English 36 Insulated Assembly Insulated Assembly Insulated Assembly Insulated Assembly PET3 Foam Tube Pi Pipe 09 52 mm 1 Pipe 012 70 mm 1 Pipe 015 88 mm 1 i ipe 06 35 mm 1 SAk09 12 XKTBXX KKK Insulation 1 Q E Vinyl Tapes 2 Rubber Legs 4 Pipe Clamps A 3 Pipe Clamps B 3 Cement Nails 6 M4 x 25 Tapped Drain Hose a Screws 6 length 2 m 1 Putty 100 g 1 Foam Insulation 1 2015 1 17 16 48 12 aa A Fixing the installation plate You can select the direction of the drain hose depending on where you want to install the indoor unit
33. del CO IB amp IM_DB68 05272A_EN indd 53 D 2015 1 17 16 48 29 aaa o How to connect your extended power cables Items to prepare compressor and insulation tape should be prepared by an installation technician Tools Crimping pliers Connection sleeve mm Insulation tape Contraction tube mm Spec MH 14 20x07 0 HxOD Width 18 mm 50x08 0 LxOD Shape O aa A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 54 1 Asshownin the figure peel off the shields from the rubber wire of the power cable Peel off 20 mm of the wire shields of the tube installed already A After peeling off the tube wire you must insert a contraction tube CAUTION 2 Insert both sides of core wire of the power cable into the connection sleeve 3 Using a compressor compress the two points and flip it over and compress another two points in the same location The compression dimension should be 8 0 After compressing it pull both sides of the wire to make sure it is firmly pressed 4 Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape 5 Apply heat to the contraction tube to contract it 40 mm i _ tube 6 After tube contraction work is completed wrap it with the insulation tape to finish ing tape In case of extending the electric wire please DO NOT use a round shaped pressing socket warning Incomplete wire connec
34. der no circumstances must sanitary type copper pipe be used There are 2 refrigerant pipes of different diameters The smaller one is for the liquid refrigerant The larger one is for the gas refrigerant A short pipe is already fitted to the air conditioner You may need to extend the pipe using the assembly pipe optional The connection procedure for the refrigerant pipe varies according to the exit position ofthe pipe when facing the wall Right A Left B Underside C Rear 1 Cut out the appropriate knock out piece A B C on the rear of the indoor unit unless you connect the pipe directly from the rear 2 Smooth the cut edges 3 Remove the protection caps of the pipes and connect the assembly pipe to each pipe Tighten the nuts first with your hands and then with a torque wrench applying the following torque E Ifyou want to shorten or extend the pipes refer to page 43 44 NOTE 4 Cut off the remaining foam insulation 5 If necessary bend the pipe to fit along the bottom of the indoor unit Then pull it out through the appropriate hole gt The pipe should not project from the rear of the indoor unit b The bending radius should be 100 mm or more 6 Pass the pipe through the hole in the wall A Torque Outer Diameter Nem kgf cm 06 35 mm 14 18 140 180 69 52 mm 34 42 350 430 612 70 mm 49 61 500 620 615 88 mm 68 82 690 830 7 For f
35. dicator starts to blink 3 Press the SET button to set the Fast function Fast gt Fast indicator will be displayed on the remote controller display and Fast function will begin SET gt Press the Options button gt Press the 2 or Options button to C l ee make the Fast indicator blink and press the SET button Fast function is only available in Cool mode NOTE Vertical air swing can be adjusted Set temperature and fan speed cannot be adjusted If the Fast function is selected while 2 Step Cooling Comfort Single user Quiet good sleep function is on corresponding function will be cancelled Remote controller display English 20 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 20 D 2015 1 17 16 48 02 o A Using the Comfort function You can set the Comfort function to provide mild cooling When the air conditioner is operating in Cool mode 1 Press the Options button 2 Press the Q or Options button until Comfort indicator starts to blink 3 Press the SET button to set the Comfort function Comfort Comfort indicator will be displayed on the remote controller display and Comfort function will begin SNOILdO 0 gt Press the Options button Press the CJ 2 or Options button to C l iS make the Comfort indicator blink and press the SET button Comfort function is only available in Cool mode Cool NOTE Vertical air swing can b
36. e remote controller display When the icon appears change remote controller and pull up the batteries The remote controller requires two 1 5V AAA 2 Insert two AAA batteries type batteries Check and match the 4 and signs accordingly Make sure you have inserted the batteries in correct position Storing the remote controller 3 Close the cover by place it back to its original position When you do not use the remote controller for long time You should hear click sound when the cover is locked properly remove the batteries from the remote controller and store it The signal may not be received properly if electronic flourescent lamps such as inverter flourescent lamps are operating in the same space NOTE Ifother electrical products operate by the remote controller call your nearest contact center E Correct disposal of batteries in this product Applicable in countries with separate collection systems This marking on the battery manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in EC Directive 2006 66 If batteries are not properly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse plea
37. e adjusted st fe Set temperature can be adjusted but fan speed cannot be adjusted Ifthe Comfort function is selected while 2 Step Cooling Fast Single user Quiet good sleep function is on corresponding function will be cancelled Remote controller display Using the Virus Doctor function This function will produce positive ions and supply them into the airflow When the air conditioner is operating 1 Press the Options button user Sw 2 Press the C Dor Options button until 273 indicator starts to blink 3 Press the SET button to set the Virus Doctor function ED C9 indicator will be displayed on the remote controller display and Virus Doctor function will begin gt Press the Options button Press the 2 F or Options button to C l 0 anes make the 3 2 indicator blink and press the SET button Virus Doctor lamp will turn on when the Virus Doctor function turns on and it will turn off when the function is cancelled Virus Doctor function can be selected while Auto Cool Dry Fan mode ison Auto DOLE LA Set temperature can be adjusted There will not be much difference on energy consumption and operating noise when the Virus Doctor function is selected additionally while the other function is on When the Virus Doctor function is selected with other operation mode pressing the Power button will stop the operation Remote controller displa
38. e is well less Ditch drained Keep a clearance of at least Do not place the end of the 5 cm between the end of the drain hose in a hollow drain hose and the ground 1 Correct connection a Al piz EA J I Drain hose Pipe Drain hose Pipe 3 Don t tie drain hose to the assembly pipe which may lead to water leakage Ifthe diameter of the connection hose is smaller than the product s drain hose water leakage may occur CAUTION I Drain hose installation 1 If necessary connect the 2 meter extension drain hose to the drain hose 2 If you use the extension drain hose insulate the inside of the extension drain hose with a shield 3 Fit the drain hose into 1 of 2 drain hose holes then fix the end of the drain hose tightly with a clamp Ifyou do not use the other drain hose hole note blockit with a rubber stopper 4 When extending the Drain Hose hold the end of Drain Hose and Extended Hose Va rotate and insert the drain hose into Extended hose for 40 45 mm Make surethe Y two hoses are firmly connected there is no water leakage Drain hose hole 5 Connect the Drain Hose after using F
39. entral part WD e mm Caution fragile Caution fragile Gently press the both side of the cover Use both hands panel inwards D and release the hooks a TANAN Pn both pr a Release each hook by pushing it up at an angle Assembling the Cover panel After mounting the indoor unit To assemble the Cover panel proceed in reverse order of disassembling Use both hands for assembling and be extra careful not to damage the pipes and drain hose Lock the side center and bottom hooks in this sequence Tighten the bottom panel with the screws and close the screw holes with their cap lt Fasten the screws lt Assemble the Cap screws English 39 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 39 D 2015 1 17 16 48 20 aaa A Connecting the assembly cable I Cable specification Model Power cable Interconnection cable Type GL 3GXAWG16 SJT 2 09 12 3G1 0mm HOSW F 4G1 5mm HO7RN F 20A 2 3G1 0mm HO7RN F 418 24 3G2 5mm HO7RN F 3x0 35m HOSRN E 25A Connect the power cable to the auxiliary circuit breaker If every pole fails to connect to the NOTE power supply it must be incorporated in a wire with a contact opening of 23 mm Use shield cable Category 5 less than 50pF m for noisy environmental site Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord Code designation IEC 60227 IEC 53 CENELE
40. erant tubes and protections regularly These operations should be performed by qualified personnel only The unit contains moving parts which should always be kept out of the reach of children Do not attempt to repair move alter or reinstall the unit If performed by unauthorized personnel these operations may cause electric shocks or fires Do not place containers with liquids or other objects on the unit All the materials used for the manufacture and packaging of the air conditioner are recyclable The packing material and exhaust batteries of the remote controller optional must be disposed of in accordance with current laws The air conditioner contains a refrigerant that has to be disposed of as special waste At the end of its life cycle the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely Installing the unit IMPORTANT When installing the unit always remember to connect first the refrigerant tubes then the electrical lines gt Always disassemble the electric lines before the refrigerant tubes Upon receipt inspect the product to verify that it has not been damaged during transport If the product appears damaged DO NOT INSTALL it and immediately report the damage to the carrier or retailer if the installer or the authorized technician has collected the material from the retailer English 31 A3050 INV ED Good Model CO IB amp
41. heck the connection of the connector E 154 O O 9 Error on indoor fan motor 2 Remove foreign substance Check for the cause that restrains motor ER display and all 1 Re set options LED blinks 0 90 O EEPROM Option error E 52E 163 1 Check if the service valve is completely open Refrigerant flow blocking 2 Check if there s any blockage in the refrigerant E422 O Q E Error 9 pipe which connects indoor and outdoor unit 3 Check for refrigerant leak O O Q 1 Check if sufficient amount of additional refrigerant was charged for the pipe length that EGGUY gt Above LED pattern is displayed when Lack of Refrigerant exceeds 7 5m there s error is occurred on outdoor unit 2 Check for refrigerant leak between valve and pipe connection O 0ff Y Blinking On English 52 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 52 2015 2 11 11 19 46 aaa ee Final check and trial operation To complete the installation perform the following checks and tests to ensure that the air conditioner operates correctly Check the followings Strength of the installation site Tightness of pipe connection to detect gas leak Electric wiring connection Heat resistant insulation of the pipe Drainage Grounding conductor connection Correct operation follow the steps below NOILVTIVISNI ZO 1 Press the Power l button and check the following gt The indicator on the indoor unit
42. iance is running in a smoky area Ventilate the the room during room or operate the air conditioner in Fan mode for 1 2 hours operation We do not use smelly components in the air conditioner Check the Drains have been cleared Regular Maintenance Error is indicated e When an indoor unit indicator blinks contact the nearest service center Please ensure the error code is passed onto the service center when booking the service call Noise is generated Depending on the status of the air conditioner usage noise can be heard when refrigerant flow movement changes It is normal Water is dropping from the outdoor unit piping connection Water may be generated because of the temperature difference It is normal A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 30 D English 30 2015 1 17 16 48 09 OA mi Safety precautions Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components Verify that installation and testing operations are performed by qualified personnel Verify that the air conditioner is not installed in an easily accessible area General information gt NOILVTIVLSNI ZO Carefully read the content of this manual before installing the air conditioner and store the manual in a safe pl
43. ill be helpful to refresh the stale air in your room English 14 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 14 D 2015 1 17 16 47 56 L A Basic function Press the button to turn on the air conditioner Press the button to set the operating mode Each time you press the Mode button the mode will change in order of Auto Cool Dry and Fan Auto Set um c Set um e Set um C o HE rp LENS P gt Cool BR K4 Lae NOILINNADISVE ZO Press the rere button to adjust the temperature Auto You can adjust the set temperature by 1 C within the range of 16 C 30 C Cool You can adjust the set temperature by 1 C within the range of 16 C 30 C Dry You can adjust the set temperature by 1 C within the range of 18 C 30 C Fan Temperature adjustment is not possible Z Press the ran button to set the desired fan speed NS Auto Auto Cool Dl Auto Dl Low Dl Med Bl High LEl Turbo Dry Auto Fan Low Y Med 4 High Turbo B Dry mode is only available in the cooling mode NOTE English 15 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 15 D 2015 1 17 16 47 56 o A Adjusting the air flow direction This function will allow you to adjust the air flow direction vertically Press the button to make air flow blades vertically I Vertical
44. indows Check if the air conditioner has just been turned on after stopping cooling operation In this case just a fan will run to protect the outdoor unit compressor Check if the pipe length is too long When the pipe length exceeds maximum allowable pipe length cooling performance may decrease Air flow adjustment Check if you have selected good sleep mode In cool mode you is not working cannot adjust the air flow direction English 29 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 29 D 2015 1 17 16 48 09 Troubleshooting PROBLEM SOLUTION Fan speed Check if you have selected Auto Dry Fast Comfort good sleep adjustment is not working mode In these mode fan speed is set to Auto and you cannot adjust the fan speed Remote controller is Check if your batteries are depleted not working Make sure nothing is blocking your remote controller sensor e Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves Timer function does Check if you press the SET button on the remote controller after not set you have set the time The indicator Press the Power button or disconnect the power plug switch is blinking off the auxiliary power switch continuously If the indicator is still blinking contact the service center Odors permeate in e Check if the appl
45. injury or property damage Q Follow directions Cut off the power supply O Do NOT attempt O Do NOT disassemble a Make sure the machine is grounded to prevent electric shock FOR INSTALLATION 44 WARNING Use the power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line gt Extending the power line may result in electric shock or fire gt gt Do not use an electric transformer It may result in electric shock or fire gt If the voltage frequency rated current condition is different it may cause fire The installation of this appliance must be performed by a qualified technician or service company gt Failing to do so may result in electric shock fire explosion problems with the product or injury and may also void warranty on the installed product Install a Isolation Switch next to the Air Conditioner but not on the panels of the Air Conditioner and circuit breaker dedicated to the air conditioner B Failing to do so may result in electric shock or fire Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed gt Failing to do so may result in electric shock fire explosion problems with the product English 4 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 4 D 2015 1 17 16 47 53 Do not install this appliance near a heater inflammable materia
46. inner kerosene and acetone etc to clean the surface of the product or put any stickers on it They may damage the surface of the air conditioner Cleaning the outdoor unit heat exchanger gt When dust accumulates on the heat exchanger it may decrease cooling performance Therefore clean it regularly gt Spray water to clean the dust No 22S Ni RE CERN LS If it is difficult to clean the outdoor unit heat exchanger on NOTE your own contact service center ROOZE IRR e Be careful with the sharp edges on the Heat exchanger CAUTION outdoor unit heat exchanger Illustration may differ slightly depending on the models English 25 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 25 D 2015 1 17 16 48 07 o A Cleaning the air conditioner Removing the Air filter Air filter There is a hole on the bottom right side of the filter Put your finger in that hole to get a grip on the filter and slightly push it up to release the hooks from the bottom side Then pull it down to remove the filter from the main body I Cleaning the air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing 7 Remove the Air filter from the main body Clean the Air filter with a vacuum cleaner or soft brush p If dust is too heavy rinse it with running water
47. it disappears Combining On Timer and Off Timer When the air conditioner is off When the air conditioner is on When set time on On timer is shorter than Off timer When set time on On timer is longer than Off timer Ex On timer 3 hours Off timer 5 hours Ex On timer 3 hours Off timer 1 hour The air conditioner will turn on after 3 hours from the The air conditioner will turn off after 1 hour from the moment you have set the timer and the air conditioner will moment you have set the timer and turn on after 2 hours remain on for 2 hours and then turn off automatically from the moment it was turned off Set time for the On timer and the Off timer should be different from each other English 18 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 18 D 2015 1 17 16 47 59 good sleep mode For a comfortable sleep the air conditioner will operate in 3 stages in order of Fall asleep gt Sound sleep gt Wake up stage When the air conditioner is operating in Cool mode 1 Press the Timer button to select ES 2 indicator will keep blinking and you can set the time 2 Press the You can set the time in half hour unit from 30 minutes 0 5 on the display 3 hours and hour unit from 3 12 hours Time can be set from minimum 30 minutes to maximum 12 hours iran HIWIL 0 Default time setting for the good sleep mode is 8 hours 3 Press the SET button to complete the good sleep mode setting
48. l Do not install this appliance in a humid oily or dusty location in a location exposed to direct sunlight and water rain drops Do not install this appliance in a location where gas may leak B This may result in electric shock or fire Never install the outdoor unit in a location such as on a high external wall where it could fall gt Ifthe outdoor unit falls it may result in injury death or property damage This appliance must be properly grounded Do not ground the appliance to a gas pipe plastic water pipe or telephone line gt Failure to do so may result in electric shock fire and explosion B Make sure to use a socket outlet with ground NOIIVuVdJyd LO FOR INSTALLATION ACAUTION Install your appliance on a level and hard floor that can support its weight B Failing to do so may result in abnormal vibrations noise or problems with the product Install the draining hose properly so that water is drained correctly gt Failing to do so may result in water overflowing and property damage Avoid adding drain to waste pipes as odours may arise in the future When installing the outdoor unit make sure to connect the draining hose so that draining is performed correctly gt The water generated during the heating operation by the outdoor unit may overflow and result in property damage In particular in winter if a block of ice falls it may result in injury death or property damage FOR POWER SUPPLY WA
49. l the air conditioner with excessive force gt This may result in fire injury or problems with the product NOILvY4vd34d LO Do not place an object near the outdoor unit that allows children to climb onto the machine gt This may result in children seriously injuring themselves Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people gt Since this may be dangerous due to a lack of oxygen Open a window at least once an hour Ifany foreign substance such as water has entered the appliance cut off the power supply and contact the nearest service center gt Failing to do so may result in electric shock or fire Q Donot attempt to repair disassemble or modify the appliance yourself gt gt Do not use any fuse such as cooper steel wire etc other than the standard fuse B Failing to do so may result in electric shock fire problems with the product or injury English 7 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 7 D 2015 1 17 16 47 54 Safety precautions FOR USING ACAUTION Donot place objects or devices under the indoor unit gt Water dripping from the indoor unit may result in fire or property damage example electrical appliances Check that the installation frame of the outdoor unit is not broken at least once a year B Failing to do so may result in injury death or property damage Max current is measured according
50. lights up The airflow blade opens and the fan gears up for operation 2 Press the Mode button to select Cool mode gt In Cool mode use Temp or button and set the temperature at 16 C Approximately 3 5 minutes later outdoor unit will start to operate and the Note Cool air will blow out After 12 minutes of stationary condition check the indoor unit air treatment Cooling mode indoor unit check Inlet air temp Outlet air temp From 10 C to 12 C indicative delta T 3 Press the Air swing button and check the following gt The airflow blades work properly 4 Press the Power button to stop the operation When you complete the installation successfully hand over this manual to the user for storage in a handy and safe NOTE place Pump down procedure when removing the product 1 Press the Power l button on the indoor unit for 5 seconds Beep will sound immediately to let you know that the product is ready for pump down procedure Please let the compressor run for more than 5 minutes Release the valve caps on High and Low pressure side Use L wrench to close the valve on the high pressure side After approximately 2 minutes close the valve on the low pressure side Stop operation of the air conditioner by pressing the power button on the indoor unit or remote controller a Uu a Gu N Disconnect the pipes English 53 A3050 INV ED Good Mo
51. more more NOILVTIVLSNI ZO When front and rear side of the outdoor unit is towards the wall AU eL LA hay Jk kh 1500 or 600 or 3000 or 3000 or 200 or more more more more more 300 or more E HIT 500 or more Ifinstallation is done in inappropriate space unit may generate sound and cause bad effect on the product caution Installation must be done in level and in a place where vibration will not cause any effect Accessories The following accessories are supplied with the air conditioner B The number of each accessory is indicated in parentheses NOTE I Accessories in the indoor unit case Installation Plate 1 Installation Plate 1 Remote controller Batteries for Remote 09 12 03 frame 18 24 05 frame controller 2 HE p E o User s amp Installation Manual 1 O Cap Screws 2 English 35 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 35 D 2015 1 17 16 48 11 Accessories I Accessories in the outdoor unit case 4 wire 2 wire 3 wire Assembly Cable 1 Assembly Cable 1 Assembly Cable 2 09 12 XA 18 2444 18 244 S Rubber Leg 4 JS The flare nuts are attached to the end of each pipe of an evaporator or a service port NOTE Use the nuts when connecting the pipes The assembly ca
52. ng with fan operating at high velocity Compressor will immediately start provided 3 minutes have elapsed since the last stop b After 2 minutes of operation shut the suction valve with the same wrench gt Turn the system off and switch mains supply off b Disconnect tubing After disconnection protect valves and tubing ends from dust Compressor damage may occur if run at a negative suction pressure English 49 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 49 D 2015 1 17 16 48 24 aaa o Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory After checking for gas leaks in the system insulate the pipe hose and cables Then place the indoor unit on the installation plate 1 To minimise condensation problems wrap foam insulation as shown in the figure on a part without insulation on the end of the pipes 2 Wind the pipe assembly cable and drain hose with vinyl tape 3 Place the bundle the pipe assembly cable and drain hose in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit 4 Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place Make sure pipe does not move when you install the indoor unit on an installation plate CAUTION 5 Wrap the rest of the pipe with vinyl tape 6 Attach the pipe to the wall using clamps opti
53. oam Insulation to wrap the Extended Hose Then Use vinyl tape to wrap the each side of connection by 20 mm English 45 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 45 D 2015 1 17 16 48 23 Installing and connecting the drain hose of the indoor unit 20mm 20mm 40 45 mm ormore or more Ea Gav INT qe di ZZZ Drain hose Extension drain hose Drain hose Extension drain hose VinylTape Foam Insulation 6 Pass the drain hose under the refrigerant pipe keeping the drain hose tight 7 Pass the drain hose through the hole in the wall Check if it slants Shield downwards as seen in the picture gt a er 8 Using natural drainage method check the drainage is normal PI A gt ZI Drain hose Extension drain hose The hose will be fixed permanently into position after finishing the installation and the gas leak test refer to page 50 for further details Make sure the installed direction of the drain hose is correct Inadequate installation may cause condensate water leakage Ifthe drain hose is routed inside the room insulate the hose so that dripping condensation does not damage the furniture or floors DO NOT WALL UP THE DRAIN HOSE CONNECTION Drain hose connection must be easy accessible and serviceable Changing direction of the drain hose Change the direction only when it is necessary 1 Detach the rubber cap with the pliers 2 Detach the drain hose b
54. ode is set over 5 hours Wake up stage will begin when 1 hour is remaining in the operation time and the air conditioner will stop automatically When the On timer and the good sleep function is set simultaneously the air conditioner will only apply the function that was set later English 19 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 19 D 2015 1 17 16 48 01 o A 2 Step cooling function 2 Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature When the air conditioner is operating in Cool mode 1 Press the Options button 2 Press the Q or Options button until 2 Step indicator starts to blink 3 Press the SET button to set the 2 Step Cooling function 2 Step 2 Step indicator will be displayed on the remote controller display and 2 Step Cooling function will begin gt Press the Options button Press the C gt or Options button to C l di make the 2 Step indicator blink and press the SET button Remote controller display Using the Fast function You can set the Fast function to provide fast and powerful cooling When the air conditioner is operating in Cool mode 1 Press the Options button 2 Press the F or Options button until Fast in
55. onal Fixing the outdoor unit in place Insulation OK amp Pipes Installation plate Vinyl tape Connecting wires Drain hose Install the outdoor unit in level on a stable base to help avoid the generation of noise and vibration especially when installing the unit close to a neighbor If you install the outdoor unit in a place exposed to strong winds or at a height fix it to an appropriate support wall or ground 1 Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly 2 Fix the outdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exposed to strong winds install shield plates around the outdoor unit so that the fan can operate correctly Secure the rubber leg to help prevent the generation of noise and vibration NOTE I Outdoor unit installed on the wall by rack Ensure the wall will be able to suspend the weight of rack and outdoor unit Install the rack close to the column as much as possible Install proper grommet in order to help reduce noise and residual vibration transferred by outdoor unit towards wall Soft rubber designed to cut off vibration from rack to wall not supplied with product English 50 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 50 X mm gt a Rubber leg Model X Y 09 12 507 292 K1B EK
56. ons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance NOILV4vd3dd LO FOR CLEANING 4AWARNING Do not clean the appliance by spraying water directly onto it Do not use benzene thinner or alcohol to clean the appliance B This may result in discoloration deformation damage electric shock or fire Before cleaning or performing maintenance cut off the power supply and wait until the fan stops B Failing to do so may result in electric shock or fire FOR CLEANING ACAUTION Take care when cleaning the surface of the heat exchanger of the outdoor unit since it has sharp edges gt This should be done by a qualified technician please contact your installer or service center Donot clean the inside of the air conditioner by yourself P For cleaning inside the appliance contact your nearest service center gt When cleaning the internal filter refer to the descriptions in the Cleaning the air conditioner section gt Failure to do may result in damage electric shock or fire We suggest that the temperature should be set between 21 C 23 C to red energy consumption gt The air conditioner should be turned off in an unoccupied areas gt
57. result in problems with the product water leakage electric shock or fire B A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged B Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air please contact your nearest service center Do not touch the circuit breaker with wet hands B This may result in electric shock Do not turn the air conditioner off with the circuit breaker while it is operating Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire After unpacking the air conditioner keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children gt fa child places a bag over its head it may result in suffocation English 6 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 6 D 2015 1 17 16 47 54 S Donottouch the air flow blade with your hands or fingers during the heating operation B This may result in electric shock or burns Do not insert your fingers or foreign substances into the air inlet outlet of the air conditioner gt Take special care that children do not injure themselves by inserting their fingers into the product Do not strike or pul
58. se separate batteries from other types of waste and recycle them through your local free battery return system English 13 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 13 D 2015 1 17 16 47 55 o A Basic function Basic operation is an operation mode that can be selected by pressing the Mode button Auto 2 Step Cooling In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature 2 Step Cooling mode sets the air conditioner to operate in Fast Cool mode when set temperature is lower than indoor temperature and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season If current outside temperature is much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness e Quiet mode makes the noise quieter during the operation of the indoor unit in the Cool mode Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate To activate the Dry mode set temperature on the remote controller should be lower than indoor room temperature Fan Fan mode can be selected to circulate your room Fan mode w
59. splay and the Timer indicator will be displayed on the indoor unit display On timer setting will be cancelled ifyou don t press the SET button within 10 seconds after setting the time Therefore check for the On indicator on the remote controller display and the Timer indicator on the indoor unit display HIWIL 0 gt Press the Timer button gt select On press the 7 or button Cancel set the timer to Al press the SET button gt Press the Power button Remote controller display Additional options available in On time You can select from Auto Cool Dry Fan T You can set the temperature after selecting the operation mode Temperature adjustment is available when Auto Cool Dry mode is selected When On timer setting is completed the set status will be displayed for 3 seconds and then only On indicator will remain on the remote controller display thereafter Ifyou press the Power button on the indoor unit after setting the On timer from the remote controller Timer indicator on the indoor unit display will disappear and the On timer will be cancelled Even though the On timer is cancelled On indicator on the remote controller will remain displayed When the On timer is set while the air conditioner is off Timer indicator D will be displayed and remain on until the On timer turns on English 17 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd
60. stallation In order to install the indoor unit you must disassemble the cover panel first Please proceed following instructions to disassemble and assemble the cover panel Hooks on the cover panel may get damaged if you apply excessive force as you disassemble and assemble the cover panel Please follow the following instructions I Removing the screws Cover panel is assembled on the bottom part of the indoor unit as shown in the illustration and it is fastened with screws Remove the Cap screw first and unfasten the screws so that you can disassemble the cover panel Cover Panel lt Unfasten the screw gt English 38 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 38 D 2015 1 17 16 48 15 o mi Removing the Cover panel Before mounting the indoor unit The bottom panel fits the main body using the side center and bottom hooks as shown Unlock the side hooks first and then unlock the center and bottom hooks Check the location of the hooks before removing the cover panel gt Location of the hooks on the central part Number and location of the hooks f Side i hooks NOILYTIYLSNI ZO Center hook Center a hooks Bottom hooks For specific Hook location and quantity please refer to cover panel with indicating arrows based on physical goods gt Removing the hooks on the side gt Removing the hooks on the c
61. the flare nuts first with your hands and then with a torque wrench applying the following torque Flarenut Outer Diameter IRE Nem kgf cm 66 35 mm 14 18 140 180 o 69 52 mm 34 42 350 430 612 70 mm 49 61 500 620 Indoor outlet pipe Connecting pipe 615 88 mm 68 82 690 830 Excessive torque can be cause of gas leakage If extending pipe by welding brazing please ensure nitrogen is NOTE used during welding brazing process The joint must be accessible and serviceable 7 For further details on how to connect to the outdoor unit and evacuate the air refer to page 47 48 Tighten the flare nut with torque wrench according to specified method caumon lfthe flare nut is over tightened the flare may break and cause refrigerant gas leakage English 44 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 44 D 2015 1 17 16 48 22 aaa o Installing and connecting the drain hose of the indoor unit When installing the drain hose for the indoor unit check if condensation draining is adequate When passing the drain hose through the 65 mm hole drilled in the wall check the followings Wall o N z a i 0 Indoor unit gt Drain hose 2 The drain hose must NOT The end of the drain hose The drain hose must not slant upwards must NOT be placed under be bent water After completing the installation of the drain hose pour water into 0 0 the drain pan to check 5cm whether the hos
62. the power supply There may be internal damage if moisture is left in components 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helps remove odors which may have generated from dampness Periodical checks Refer to the fo Type llowing chart to maintain the air conditioner properly Description Every 2 weeks Every 3 months Every 4 months Once a year Clean the air filter 1 Clean the condensate drain pan 2 Indoor Thoroughly clean the heat exchanger 2 unit Clean the cross fan 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Clean the heat exchanger on the outside ofthe unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Outdoor unit Verify that all the electric components are firmly tightened 2 Clean the fan 2 Verify that all the fan assembly is firmly tightened 2 Clean the condensate drain pan 2 This check mark requires checking the indoor outdoor unit periodically Follow the description to maintain the air conditioner properly CAUTION 1 The described operations should be performed more frequently if the area of installation is very dusty 2 These operations must always be performed by qualified personnel
63. tions can cause electric shock or a fire AJ English 54 Unit mm Power cable provided by us nsulation tape D 2015 1 17 16 48 29 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 55 English 55 NOILVTIVISNI ZO 2015 1 17 16 48 30 _ IP QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT MEXICO 01 800 SAMSUNG 726 7864 www samsung com mx support 0800 124 421 Demais cidades e regi es BRAZIL 4004 0000 Capitais e grandes centros www samsung com br support 0 800 507 7267 www samsung com latin support Spanish COSTA RICA 00 800 1 SAMSUNG 726 7864 www samsung com latin_en support English BAN LI www samsung com latin support Spanish DOMINICA 800 751 2676 www samsung com latin_en support English 1 800 10 72670 www samsung com latin support Spanish ECUADOR 1 800 SAMSUNG 72 6786 www samsung com latin_en support English www samsung com latin support Spanish EL SALVADOR 800 6225 www samsung com latin_en support English 1 800 299 0013 www samsung com latin support Spanish GUATEMALA 1 800 299 0033 www samsung com latin_en support English 800 27919267 www samsung com latin support Spanish D HONDURAS 800 2791 9111 www samsung com latin_en support English 1 800 234 7267 A JAMAICA 1 800 SAMSUNG 726 7864 www samsung com latin_en support English 200 www samsung com latin support Spanish NIC
64. ts vibration and is strong enough to hold the product weight Out of the direct sunlight 1 m or more away from the TV or radio to prevent the screen from being distorted or noise from being generated As far away as possible from the fluorescent and incandescent lights s0 that the remote controller can be operated well A place where the air filter can be replaced easily Don t install directly above electronics equipment as leaking water may cause damage if not serviced eg Computers TV etc vv vvvvvy English 32 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 32 D 2015 1 17 16 48 09 I Outdoor Unit Where it is not exposed to strong wind Well ventilated and dustless places Where possible keep out of sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong enough to hold the product weight Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit legs 3mor more away from the TV or radio to prevent the screen from being distorted or noise from being generated Install the unit horizontally Place where drained water does not become any problem Place with no plants especially climbing plants and where small animal can not access Outdoor unit should not be place higher than 2 4 m or directly under eaves for accessibility for service and OH amp S reasons NOILVTIVLSNI ZO vv
65. ump A Vacuum gt Check for 2 minutes if there is any pressure change Liquid service port Pump gt Remove the hose of the low pressure side of manifold gauge lt High pressures kaa art aa prevention 6 Seta valve cork of liquid and gas service port to the open position English 47 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 47 D 2015 1 17 16 48 24 o A Evacuating the connected pipes Adding Refrigerant Add refrigerant charge according to table below If you use a pipe longer than 7 5 m 115 of refrigerant R 410A must be added for each extra meter Ifyou use a pipe shorter than 7 5 m The evacuate time is normal Refer to the Service Manual for further details The remaining air in the Refrigeration cycle which contains moisture may cause malfunction on the compressor caution Always contact the service center or a professional installation agency for product installation Charging the refrigerant under conditions of liquid by using a liquid pipe R 410A is a mixed type of refrigerant It is necessary for recharging under conditions of liquid When recharging refrigerant from the refrigerant cylinder to the equipment follow the instructions below 1 Before recharging check whether the cylinder has a siphon or not There are two ways to recharge the refrigerant Cylinder with siphon l Cylinder without siphon O Siphon Charge the refrigerant standing the i
66. urther details on how to connect to the outdoor unit and evacuate the air refer to page 47 49 The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test note referto page 50 for further details Tighten the flare nut with torque wrench according to specified method caumon Ifthe flare nut is over tightened the flare may break and cause refrigerant gas leakage DO NOT WALL UP THE PIPE CONNECTION All refrigerant pipe connection must be easy accessible and serviceable English 42 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 42 D 2015 1 17 16 48 21 aaa A Evacuating the indoor unit The indoor unit is supplied with inert gas nitrogen Before installing the unit check if nitrogen gas flow out of indoor unit If this one isn t true DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit 1 Unscrew the caps at the end of each pipe gt All inert gas exhausts from the indoor unit To prevent dirt or foreign substances from getting into the pipes Note during installation do NOT remove the caps completely until you are ready to connect the pipes NOILVTIVISNI ZO The remaining air in the Refrigeration cycle which contains moisture caution May cause malfunction on the compressor Always contact the service center or a professional installation agency for product installation Pipes Unscrew the caps C
67. utting or extending the pipe The length of the pipe can be Extended up to see table page 33 Shorten up to see page 33 Ifyou need a pipe longer than 7 5 meters caution You must add refrigerant to the pipes otherwise the indoor unit may freeze 1 Make sure that you have all the required tools pipe cutter reamer flaring tool and pipe holder 2 If you want to shorten the pipe cut it using a pipe cutter ensuring that the cut edge remains at 90 with the side of the pipe see below examples of correct and incorrect cut edges 3 To preventa gas leak remove all burrs at the cut edge of the pipe using a reamer A Face the pipe down while removing the burrs to make sure that burrs do not get in to the pipe CAUTION English 43 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 43 D 2015 1 17 16 48 21 SSE mb Cutting or extending the pipe 4 Puta flare nut slightly into the pipe and modify the flare D Outer Diameter D Depth A Flaring Size B Paes D pth A g B pap 06 35 mm 1 3 mm 8 7 9 1 mm 2 Br 69 52 mm 1 8mm 128 13 2mm e HA E 612 70 mm 2 0 mm 16 2 16 6 mm Z EE pan 015 88 mm 2 2 mm 19 3 19 7 mm n gt oO 5 Check if you flared the pipe correctly see examples of incorrectly flared pipes below Correct Inclined Damaged Cracked Uneven Surface Thickness 6 Align the pipes to connect them easily Tighten
68. vvvvrvvvvvy Avoid the following places to prevent malfunction of the unit caumon Where there is machine oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere areas 100 mm or more Outdoor Unit 125 mm 125 mm or Outer wall or more more Indoor ae Unit You can select the direction of draining left or right Wrap the refrigerant pipes and the Cut insulation to drain hose with the absorbent pad have rainwater and vinyl tape Refer to page 50 for drained further details Lm as maximum pipe length H meters Make an U trap A on the pipe which is connected CAUTION to the indoor unit at outer Walland cutthe bottom meters maximum total part of the insulation about 7 10 mm to prevent rainwater L pipe length from getting inside through HA the insulation However be careful not to damage the pipe and 3 m as minimum pipe length maximum CAUTION It will reduce noise and vibration total pipe height Model L 09 12 15 KA18 24X 30 15 Make at least one round It will help reduce noise and vibration gt The appearance of the unit may be different from the diagram depending on the model English 33 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 33 D 2015 1 17 16 48 09 o A Choosing the installation location I
69. with current safety standards Always install the air conditioner in compliance with current local safety standards Always verify that a suitable grounding connection is available gt Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Always verify that the cut off and protection switches are suitably dimensioned Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual gt Always verify that electric connections cable entry section of leads protections are compliant with the electric specifications and with the instructions provided in the wiring scheme Always verify that all connections comply with the standards applicable to the installation of air conditioners Choosing the installation location I Indoor unit gt ForWi Fi Air conditioner installation select indoor unit location near to wireless router In case Wi Fi signal strength weakened Smart APP may be disconnected depending on the Wi Fi signal strength gt Where airflow is not blocked Where cool air can be distributed throughout the room Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram Wall that preven
70. y English 21 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 21 D 2015 1 17 16 48 04 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 22 D o A Using the Virus Doctor function When the air conditioner is not in operation 1 Press the Options button 2 When the ES indicator blinks press the SET button to select the Virus Doctor function 53 623 indicator will be displayed on the remote controller display and Virus Doctor function will begin F gt SET PC o gt Press the Options button to make the tO indicator blink and press Cancel the SET button gt Press the Power button Using the Quiet function You can reduce the noise generated from an indoor unit during Cool mode When the air conditioner is operating in Cool mode 1 Press the Options button 2 Press the CJ C or Options button until Quiet indicator starts to blink 3 Press the SET button to set the Quiet function Quiet Quiet indicator will be displayed on the remote controller display and Quiet function will begin gt Press the Options button Press the 9 C or Options button to G I i make the Quiet indicator blink and press the SET button Additional options available in Quiet function You can adjust the set temperature by 1 C within the range of 16 C 30 C Quiet Fan speed is set to 4B Auto Vertical air swing can be selected
71. y pulling it and turning to the right 3 Insert the drain hose by fixing it with the screw into the groove of the drain hose and the outlet of the drain pan 4 Attach the rubber cap with a screwdriver by turning it to the left until it fixes to the end of the groove 5 Check for leakage on both side of the drain outlet English 46 A3050 INV ED Good Model CO IB amp IM_DB68 05272A_EN indd 46 D 2015 1 17 16 48 23 Pour the water in direction of arrow K Direction of the drained water gt Make sure the indoor unit is in upright position when you pour water to check for leakage curon Make sure that the water does not overflow onto the electrical part NOILVTIVLSNI ZO Evacuating the connected pipes The outdoor unit is loaded with sufficient R 410A refrigerant Do not vent R 410A into atmosphere it is a fluorinated greenhouse gas covered by Kyoto Protocol with a Global Warming Potential GWP 2088 You should evacuate the air in the indoor unit and in the pipe If air remains in the refrigerant pipes it affects the compressor It may cause reduction of cooling capacity and malfunction Use Vacuum Pump as seen in the picture When installing make sure there is no leakage When recovering the refrigerant ground the compressor first before removing the connection pipe If the refrigerant pipe is not properly connected and the compressor works with the service valve open the pipe inhales

Download Pdf Manuals

image

Related Search

Related Contents

  User Manual - ForensicDB.org  Sennheiser MZA 10 User's Manual  Kenwood DPX-8030MD User's Manual  mise en route rapide ateq f620  IBM System x 3250 M4  Samsung HT-C550 Manuel de l'utilisateur  Applying STAMP to safety standards of mowing robots  AIR COOLED WATER CHILLERS (COOLING ONLY AND HEAT  Jabra MOTION OFFICE  