Home
Samsung AQ09UBBX manual do usuário
Contents
1. features Of your new air conditioner e Cool Summer Offer On those hot sweltering summer days and long restless nights there is no better escape from the heat than the cool comforts of home Your new air conditioner brings an end to exhausting hot summer days and lets you rest Beat the heat with your own air conditioner this Summer e Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but also can be an efficient heating method in the winter with the advanced Heat pump system Heat pump system is 3 times more efficient compare to the other electrical heating appliance so you can further reduce its running cost Now meet year round needs with one air conditioner e Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior d cor With its soft color and rounded edge shape the new air conditioner adds class to any room Enjoy what your air conditioner offers both functionally and esthetically e good sleep function good sleep function allows you to set a comfortable sleep temperature while saving energy and having sound sleep SAMS For easy future reference write the model and serial number Model down You can find your model number on the bottom side Serial of the air conditioner erial 02 features Brazil AQ09R IB HP 31238A E 11 19 09 indd 2 2009 1
2. 1 Press the Smart Saver button on the remote control cal while the air conditioner is operating in Cool mode SET TEMP yy 4 C Smart Saver indicator and air swing indicator appears automatically on the remote control display The air flow blades move up and down sig a If the current set temperature is lower than 24 C it will automatically raise to 24 C e Smart Saver function is only available in Cool mode e When Smart Saver function is activated temperature range will be limited to 24 C 30 C e f the desired temperature is lower than 24 C turn off the Smart Saver function by pressing the Smart Saver button again e Temperature Fan speed can also be adjusted see step 3 4 on page 15 for instructions e Air flow can be adjusted manually see page 19 for instructions e f you press the Mode button while the Smart Saver function is on it will cancel the function To deactivate the Smart Saving function 1 Press the Smart Saver button on the remote control while Smart Saver function is on Smart Saver function you set will be canceled and Smart Saver indicator will disappear on the remote control display 26_ using advanced functions Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 26 2009 12 9 14 56 47 TC T a cleaning and maintaining the alr conartioner Make sure the power is turned off and unplugged from the wall socket when cleaning the air caution CONditioner
3. If system contains 3 kg or more of fluorinated greenhouse gases In this case it has to be checked for leakage at least once every 12 months according to regulation n 842 2006 This activity has to be covered m by qualified personnel only 5 In the case above a maintenance book has to be available for each unit installed ae CLEANING THE EXTERIOR 1 Wipe the surface of the unit with a slightly wet or dry cloth when needed Do not use Benzene Thinner or Clorox caution hey May damage the surface of the air conditioner and can create a risk of fire CLEANING THE FILTER When cleaning the filter make sure to unplug the power from the unit No special tools are needed to clean it Air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing 1 Open the front panel Tightly grab front side of the front panel and lift up the panel to open Then slightly push the eN panel up until the panel is hanged over the hooks of the unit 2 Grab the handle and lift it up Then pull the Air filter towards you and slide it down eS SS H
4. fan speed will change in order of Low Medium and High iY e While you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually see page 19 for instructions operating 17 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 17 2009 12 9 14 56 11 TC T a E operating basic function SELECTING OPERATION MODE Heat The air conditioner heats as well as cools Warm your room with this versatile appliance in the cold of winter 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Heat SET TEMP ba qc Press the Mode button on the remote control until Heat mode indicator appears on the remote control display The air conditioner operates in Heat mode and warms your room Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temp A or V button on the remote control SET Toe C to increase or decrease the desired temperature L Wu You can set the desired temperature between the range of 16 C 30 C i You can increase decrease the temperature by 1 C 4 Set the fan speed Press the Fan lt l or gt button on the remote control to SET TEMP j set the desired fan speed CN If room temperature
5. Mode button the mode will change in order of Auto Cool Dry Fan and Heat SET TEMP al Hf C Set the temperature Press the Temp A or V button on the remote control to increase or decrease the desired temperature You can set the desired temperature between the range of 18 C 30 C You can increase decrease the temperature by 1 C selection appears on the remote control display SET TEMP ba Ei Cc IZ e While you are using the remote control make sure correct indicator which matches your e Air flow can be adjusted manually see page 19 for instructions 16_ operating Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 16 2009 12 9 14 56 07 TC T a E Fan Fan mode can be selected to ventilate your room Fan mode will be helpful to refresh the stale air in your room 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Fan mode indicator appears on the remote control display The air conditioner operates in Fan mode and circulate the indoor air HSITONA Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed Press the Fan J or gt button on the remote control to set the desired fan speed Each time you press the Fan lt or gt button
6. away from it When using the remote control always point it directly at the air conditioner Remote control display r m Turbo 2 Operate in auto fan speed to Power Mo cool warm quickly Turn on off the air conditioner a LO Mode FT Air swing Set one of the 5 operating modes Temp Activate Deactivate air flow blade see pages 14 18 for instructions movement automatically up and down Fan lt gt Adjust how much air flows Temp through the air conditioner with the 4 different fan speeds such as vu V i J Auto Low Medium High pre Saver good sleep a good sleep D y Set the good sleep mode on Smart Saver Increase Decrease the temperature by 1 C Temp AV Less energy usage makes your On off Set Set Cancel space cool between the temperature Timer Timer Cancel range of 24 C 30 C Set Cancel the timer good sleep mode On Timer 2m 71 Off Timer Set the On Timer on Set the Off Timer on Adjust the timer for on timer Adjust the timer for off timer IZ When you press the button a short beep will sound and a transmit indicator appears on the remote control display 12 viewing Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 12 2009 12 9 14 55 45 Indicator ITEMP mp am 0 good sleep indicator _ SET TEN l f C M Set temperature QM ON CD GD tH time indicator R Off Timer indicator F Sf o Transmit ind
7. carefully After reading this section keep it in a safe place for future reference safety information _03 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 3 2009 12 9 14 55 14 CEER a Wow Saiety information SEVERE WARNING SIGNS WARNING N Do not place the air conditioner near hazardous substances or equipment that releases free flames to avoid fire explosions or injuries e Potential risk of fire hazard or explosion Do not install the outdoor unit at an unstable place or elevated surface where there is potential risk of falling e f the outdoor unit falls it may cause personal injury or loss of property Failure or damage may occur if any changes or modification that is not stated in the installation manual was performed In this case user will be responsible for the repair expenses Install the air conditioner away from direct exposure to sunlight heating apparatus and humid places e Hang curtains on windows to boost cooling efficiency and to avoid the risk of electric shock Do not cut the power plug and connect to a different power cable Do not yank the power cable and touch the power plug with hands e Potential risk of fire or electric shock Never use a damaged or dusted power plug power cable or loosened power receptacle eS e Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner e Potential risk of e
8. drain pan 2 Indoor unit Thoroughly clean the heat exchanger 2 Clean the condensate drain pipe 2 Replace the remote control batteries 1 Clean the heat exchanger on the outside of the unit 2 Clean the heat exchanger on the inside of the unit 2 Clean the electric components with jets of air 2 Outdoor unit Verify that all the electric components are firmly tightened 2 Clean the fan 2 Verify that all the fan assembly is firmly tightened 2 Clean the condensate drain pan 2 This check mark requires checking the indoor outdoor unit periodically following to the description to maintain the air conditioner properly O The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner The frequency of these operations varies according to the characteristics of the area the amount of dust etc 1 The described operations should be performed more frequently if the area of installation is very dusty 2 These operations must always be performed by qualified personnel For more detailed information see the Installation Manual 28_ cleaning and maintaining Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 28 2009 12 9 14 50 58 TC T a E Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner Type Description T
9. hour the air conditioner will turn off an hour after the moment you have set the timer Your air conditioner will remain off for two hours and then it will turn on automatically See page 22 for more detail instructions on setting Off timer To deactivate the timer combination 1 Press the Set Cancel button on the remote control while timer combination is on Both of the On and Off timer will be canceled and the indicators will disappear using advanced functions 23 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 23 2009 12 9 14 56 37 TC T a KG using aavanced functions SETTING TIMER good sleep mode good sleep mode allows you to set a comfortable sleep temperature while saving energy and having sound sleep good sleep mode can be set up when the air conditioner is on 1 Set the operating mode Cool SET TEMP P IN c Press the Mode button on the remote control until Cool or Heat appears on the remote control display good sleep is only available in Cool or Heat mode 2 Press the good sleep button on the remote control good sleep indicator appears and Off timer indicator vy Lalu HR starts blinking on the remote control display 3 Set the length of time you want the air conditioner to stay on Default good sleep time is set to 8 hours O si ud Press good sleep button on the remote control
10. 2 9 14 55 14 TC T a E Salety information To prevent electric shock disconnect the power before servicing cleaning and installing the air conditioner SAFETY INFORMATION Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com HSITONA Important safety symbols and precautions Hazards or unsafe practices that may result in severe personal injury or WARNING death Hazards or unsafe practices that may result in minor personal injury or CAUTION property damage To reduce the risk of fire explosion electric shock or personal injury when CAUTION using your air conditioner follow these basic safety precautions Do NOT attempt Do NOT disassemble Do NOT touch Follow directions carefully Unplug the power plug from the wall socket Make sure the machine is grounded to prevent electric shock DEDA Call the contact center for help S Note These warning signs are here to prevent injury to you and others Please follow them
11. a CA Sy 0 E TJ tm SSS m tel 3 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse it with running water and dry it in a ventilated area K e For the best conditions repeat every two weeks e f the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a well ventilated area 4 Insert the Air filter back in its original position 5 Close the front panel cleaning and maintaining _27 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 27 2009 12 9 14 50 52 a E cleaning and maintaining tne alr conaltioner MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1 Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug There may be internal damage if moisture is left in components 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helos remove odors which may have generated from dampness Periodical checks Refer to the following chart to maintain the air conditioner properly Every 2 Every 3 Every 4 Once a Type Description weeks months months year Clean the air filter 1 Clean the condensate
12. amsung com my www samsung com ph www samsung com sg www samsung com th www samsung com vn www samsung com za 2009 12 9 14 56 59 DOP DB98 31238A 2 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 33 imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please register your product at www samsung com global register AQ12U Series AQ18U Series AQ24U Series Psa SUN 2009 12 9 14 56 59
13. anual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation won t be considered in warranty and charged to end user Ensure the off on and protection switches are properly installed Do not use the air conditioner if damaged If problems occur immediately stop operation and disconnect the plug from the power supply If the air conditioner will not be used for an extended period of time for example over several months unplug the power from the wall Call the place of purchase or a contact center if repairs are needed e Potential risk of fire or electric shock if disassembly or repairs are attempted by a non qualified service technician 08 safety information Brazil AQ09R IB HP 31238A E 11 19 09 indd 8 2009 12 9 14 55 16 TC T a contents VIEWING YOUR AIR CONDITIONER 10 Checking the indoor unit and display 10 Main parts 10 Display 11 Opening the front panel 11 Power button and Room temperature sensor 11 Checking the outdoor unit ir 12 Checking the remote control 13 Remote control display 13 Using the remote control T 13 nserting the batteries OPERATING BASIC FUNCTION 14 Turning the air conditioner on and off 14 Selecting operation mode 14 Auto 15 Cool 16 Dry 17 Fan 18 Heat 19 Adjusting the air flow direction 19 Vertical air flow 19 Horizontal air
14. de used iY e While you are using the remote control make sure corresponding indicator appears on the remote control display e Temperature Fan speed cannot be adjusted while using this function e Air flow can be adjusted manually see page 19 for instructions e f you press the Mode button while the Turbo function is on it will cancel the function 20_ using advanced functions Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 20 2009 12 9 14 56 28 TC T i E SETTING TIMER This advanced Timer function allows you to turn on off your air conditioner automatically even when you are away Simply set the time and your air conditioner will turn on off automatically On Timer This function allows you to turn on the air conditioner automatically within the time range of 24 hours On timer is available while your air conditioner is off 1 Press the On Timer button on the remote control On timer indicator blinks on the remote control display HSITONA 2 Set the time you want the air conditioner to turn on automatically Press the On Timer button on the remote control to change the time setting while On timer indicator is blinking You can set the time up to 24 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 3 Press the Set Cancel button on the remote control to active it on The remote control d
15. ding to ISO standard for energy efficiency Check for damage on delivery If damaged do not install the air conditioner and call the place of purchase immediately Keep indoor temperatures stable and not extremely cold especially where there are children elderly or disabled people The packaging material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner must be treated as chemical waste Dispose the refrigerant following national standards Have a qualified service technician install the air conditioner and perform a trial operation Firmly connect the drain hose to the air conditioner for proper water drainage Check for damages on the outdoor unit installation pad at least once a year e Potential risk of personal injury or property loss When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If the remote control is not used for a long period of time remove the batteries to prevent leakage of electrolyte When cleaning the outdoor unit touch the heat exchanger radiator fins with extreme care e Wearing thick gloves can protect your hands Make sure that the condensed water dripping from the drain hose runs out properly and safely The appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities o
16. e range of 16 C 30 C You can increase decrease the temperature by 1 C iY e While the air conditioner is already operating in another mode press the Mode button until Auto mode indicator appears on the remote control display e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually see page 19 for instructions 14_ operating Brazil AQ09R IB HP 31238A E 11 19 09 indd 14 2009 12 9 14 55 57 TC T a Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Cool SET TEMP o at LI Press the Mode button on the remote control until Cool mode indicator appears on the remote control display The air conditioner operates in Cool mode and it will lower the temperature in your room HSITSONA Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temp A or V button on the remote control SET TEMG C to increase or decrease the desired temperature Jag I You can set the desired temperature between SH the range of 16C 30 C You can increase decreas
17. e the temperature by 1 C 4 Set the fan speed Cool Press the Fan lt or gt button on the remote control to SET afe set the desired fan speed If room temperature reaches desired value the air conditioner will shut off cooling for a while and just the fan runs Each time you press the Fan lt or gt button fan speed will change in order of Auto Low Medium and High Z e While you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually see page 19 for instructions e f current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness operating _15 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 15 2009 12 9 14 56 02 TC T operating basic function SELECTING OPERATION MODE Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate Turn on the air conditioner Press the Power button on the remote control Set the operating mode Press the Mode button on the remote control until Dry mode indicator appears on the remote control display The air conditioner operates in Dry mode and automatically adjust the fan speed to Auto Each time you press the
18. equency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Use a rated circuit breaker only e Never use steel wires or copper wires as a circuit breaker It may cause fire or unit malfunctions Do not put undue stress or place heavy object on the power cable Do not bend the power cable excessively e Potential risk of fire or electric shock To protect the product from water and possible shock you should keep the power cable and the connection cord of the indoor and outdoor units in the protection tube When opening or closing the front panel use a stable stool and watch your steps carefully Disconnect the air conditioner from power supply before it is repaired or disassembled Clean the air conditioner after the inner fan stops operating e Potential risk of injury or electric shock safety information _05 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 5 2009 12 9 14 55 14 SS satety information WARNING 44 SEVERE WARNING SIGNS CONT D FH Use a receptacle that has a ground terminal The receptacle must be used exclusively for the air conditioner e Improper electrical grounding may cause electric shock or fire Be sure to ground the unit Do not connect the ground wire to gas or water pipes lighting rods or telephone grounding lines e f the unit is
19. flow USING ADVANCED FUNCTIONS 20 Using the Turbo function 21 Setting timer 21 On timer 22 Off timer 23 Combining On timer and Off timer 24 good sleep mode 25 Temperature changes in good sleep mode 26 Using the Smart Saver function CLEANING AND MAINTAINING 27 Cleaning the exterior THE AIR CONDITIONER 27 Cleaning the filter 27 Arr filter 28 Maintaining your air conditioner 28 Periodical checks 29 Internal protections via the unit control system APPENDIX 30 Troubleshooting 31 Operation ranges contents 09 Brazil AQ09R IB HP 31238A E 11 19 09 indd 9 2009 12 9 14 55 16 TC T mo VIEWING your alr conditioner Congratulations on the purchase of the air conditioner We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency Please read the user manual to get started and to make the best use of the air conditioner CHECKING THE INDOOR UNIT AND DISPLAY Carefully unpack your air conditioner and check the indoor unit to make sure it is not damaged Main parts Air filter under the panel Z Air intake ie Asn Ma up and down Blade pin lever Air flow blade left and right Display 2 Remote control receiver TR e Operation indicator i Timer indicator a Smart Saver indicator CS Power button Z Your air conditioner may slightly look different from illust
20. flow blade will move up and down automatically when the air conditioner is properly on The air conditioner will operate in the most recent operation mode used or Auto mode When you turn off the air conditioner air flow blade will stop moving and remain closed Turning on off your air conditioner without the remote control You can operate your air conditioner by pressing the Power button on the right bottom side of the air conditioner SELECTING OPERATION MODE Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature sensor 1 Turn on the air conditioner Press the Power l button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Auto mode and Auto fan speed indicator appear on the remote control display The air conditioner will automatically set the operation mode to Cool or Heat depends on the room temperature i Each time you press the Mode button the mode will change in order of Auto Cool Dry Fan and Heat Auto SET TEMP C 3 Adjust the temperature if you need to increase or decrease the room temperature Press the Temp A or V button on the remote control to increase or decrease the desired temperature You can set the desired temperature between th
21. ge of 24 hours Off timer is available while your air conditioner is on 1 Press the Off Timer button on the remote control Off timer indicator blinks on the remote control display 2 Set the time you want the air conditioner to turn off Auto automatically Press the Off Timer button on the remote control to ml AN HR change the time setting while Off timer indicator is blinking You can set the time up to 24 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours 3 Press the Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then Off timer indicator stops blinking and stays on If Off timer is not set within 10 seconds the air conditioner will end setting iY e When the Off Timer setting is done you can press the Off Timer button again to change the preset time Press the Off Timer button to change the time setting and then press the Set Cancel button to active it on e You can combine Off timer function with On timer function to turn on and then off the air conditioner at the desired time See page 23 for instructions To deactivate the Off Timer 1 Press the Set Cancel button on the remote control while Off Timer is on Off timer you set wil
22. h heating apparatus or attempt to disassemble remodel or repair it yourself e Potential risk of malfunction electric shock or fire If repairs are needed consult the contact center HSITONA Consult the place of purchase or contact center to install reinstall or disassemble the air conditioner e Improper installation carries a risk of unit malfunction water leakage electric shock or fire e f installing in specialty areas such as a factory complex or saline coastal area consult the place of purchase or contact center for specific installation details e The units must be installed according to distances declared in order to permit accessibility from each side either to guarantee correct operation of maintenance or repairing products The unit s parts must be reachable and removable completely under safety condition for people or things Consult a dealer regarding the appropriate measures to prevent the allowable concentration from being exceeded e f the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If the indoor unit gets wet turn the power off immediately and call your nearest contact center e Potential risk of fire or electric shock Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Verify that the voltage and fr
23. he internal fan will be off to against cold air when the heat pump is Against cold air heating The internal fan will be off to against cold air when the heat pump is De ice cycle y heating m G CU Anti protection of The compressor will be off to protect internal battery when the air internal battery conditioner operates in Cool mode The air conditioner does not start operating immediately to protect the Protect compressor compressor of the outdoor unit after it has been started If the heat pump is operating in Heat mode De ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures The internal fan is switched off automatically and restarted only after the de ice cycle is completed cleaning and maintaining _29 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 29 2009 12 9 14 50 58 aooenalx TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner does not operate immediately after it has been restarted Because of the protective mechanism the appliance does not start operating immediately to keep the unit from overloading The air conditioner will start in 3 minutes The air conditioner does not work at all Check that the power plug is properly connected Insert the power plug into the wall socket correctl
24. icator g db o am Low battery indicator indi Bm FU Fan speed indicator Th af E o indicator l Auto Turbo a De je cH Low NG Smart Saver indicator S89 Medium Saal High On Timer indicator Operation mode HSITONA Air swing indicator Using the remote control e Point the remote control towards the remote control receiver of the indoor unit see page 10 to find the location of remote control receiver e When you properly press the button on the remote control you will hear beep sound from the indoor unit 4 e The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps are in the same space e f other electrical products operate by the remote control call your nearest contact center Inserting the batteries 1 Push the lever as arrow 2 Insert two AAA batteries 3 Close the cover by place it indicates on the rear side Check and match the ang _ back to its original position of the remote control and signs accordingly Make You should hear click sound pull up sure you have inserted the when the cover is locked batteries in correct position properly viewing _13 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 13 2009 12 9 14 55 47 TC T operating basic function TURNING THE AIR CONDITIONER ON AND OFF Press the Power button on the remote control You will hear a beep and the air
25. isplay will show the hour s you have set for 3 seconds and set desired temperature will display The air conditioner will operate automatically at set time and then On timer indicator stops blinking and stays on If On timer is not set within 10 seconds the air conditioner will end setting 4 Set the operating mode Press the Mode button on the remote control until the SET TEMP yy C desired mode appears on the remote control display _ The air conditioner will operate in the mode you set 4 On timer function is available in Auto Cool Dry Fan Heat mode e Temperature can also be adjusted see step 3 on page 14 for instructions e All the indicators other than On Timer indicator will disappear approximately after 10 seconds after the setup e When the On Timer setting is done you can press the On Timer button again to change the preset time Press the On Timer button to change time setting and then press the Set Cancel button to active it on To deactivate the On Timer 1 Press the Set Cancel button on the remote control while On Timer is on On timer you set will be canceled and On timer indicator will disappear using advanced functions 21 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 21 2009 12 9 14 56 28 TC T a E using advanced functions SETTING TIMER Off Timer This function allows you to turn off the air conditioner automatically within the time ran
26. l be canceled and Off timer indicator will disappear 22 using advanced functions Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 22 2009 12 9 14 50 32 TC T a Combining On Timer and Off Timer You can combine the On timer and Off timer together for more convenient use of the timer function 1 Set the On timer Press the On Timer button Set the time with On Timer button Press Set Cancel button to activate the On timer See page 21 for more detail instructions on setting On timer HSINONI 2 Set the Off timer Press the Off Timer button Set the time with Off Timer button Press Set Cancel button to activate the Off timer When you set the time there can be two possible options Preset time of On Timer is shorter than Off Timer The air conditioner will turn on and then off automatically Set up should be done while the air conditioner is off ex If the preset time of the On Timer is 3 hours and the Off Timer is 5 hours the air conditioner will turn on after 3 hours from the moment you have set the timer Your air conditioner will remain on for 2 hours and then turn off automatically wag Preset time of On Timer is longer than Off Timer The air conditioner will turn off and then on automatically Set up should be done while the air conditioner is operating ex If the preset time of the On Timer is 3 hours and the Off Timer is 1
27. lectric shock or fire Do not insert anything such as fingers or branches into the air conditioner vents while the air conditioner is running e Keep the children away from the air conditioner to prevent them from putting their finger on the air conditioner Potential risk of personal injury Ensure no water gets into the air conditioner e Potential risk or electric shock e f the water gets into the air conditioner stop and unplug the power source immediately Turn off the air conditioner using the provided remote control or control accessory if provided Do not unplug to turn off the unit unless there is an immediate danger Do not run the air conditioner for an extended period of time in a room with the door closed or with babies elderly or disabled people e Open the door or windows to ventilate your room at least once an hour to prevent oxygen shortage The air conditioner is composed of moving parts Keep children away from the unit to avoid physical injury 04_ safety information Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 4 2009 12 9 14 55 14 a N Make sure that children take precautions against access to the air conditioner and they do not play with the unit Do not clean the interior of air conditioner on your own e You may damage the parts which can cause electric shock or fire e Consult contact center for cleaning the interior of the air conditioner Do not connect the air conditioner wit
28. not properly grounded electric shock may result If you smell burning plastic hear strange sounds or see smoke coming from the unit unplug the air conditioner immediately and call a contact center e Potential risk of fire or electric shock NCAUTION SIGNS CAUTION N Do not block or place items in front of the air conditioner Do not step hang onto or place heavy items on the air conditioner e Potential risk of personal injury If failure or damage occurs on the conditions of improper use not followed by the installation manual there will be an extra labor charge for installing and construction e Potential risk of malfunction electric shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner e Potential risk of electric shock fire or unit malfunction Do not open the front grille during operation e Potential risk of electric shock or unit malfunction Cool air should not flow directly towards people pets and plants e t is harmful to your health pets and plants Do not drink drain water coming out of the air conditioner e Potential risk of health hazard Do not allow children to climb on the air conditioner Do not use the air conditioner as a cooling precision instrument for food pets plants cosmetics or machinery Do not pull or give excessive shock to the air conditioner e Po
29. ode and then the air conditioner will automatically turn off when the set time has elapsed Three stage good sleep prevents you from having difficulty sleeping in summer winter night e Fall asleep Eases you into sleep by dropping the temperature e Sound sleep Relaxes your body and raises your temperature slightly e Wake up from good sleep mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh HSITONA e Set Off timer in good sleep mode over 5 hours You feel disturbed sleep if the good sleep is set too short or long because the default is set to 8 hour operation e f the good sleep mode is set less than 4 hours the operation will stop at the set time If the good sleep mode is set over 5 hours it will run as Wake up stage for the last one hour before stop e Recommended set temperature is between 25 C 27 C for cooling and 21 C 23 C for heating To deactivate good sleep mode 1 Press the Set Cancel button on the remote contro while good sleep mode is on good sleep mode you set will be canceled and good sleep indicator will disappear using advanced functions _25 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 25 2009 12 9 14 56 46 TC T a using advanced functions USING THE SMART SAVER FUNCTION This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode
30. ow direction in a constant position you prefer Blade pin lever Be extremely careful with your fingers while adjusting the Horizontal air flow direction duron here is a potential risk of personal injury when the unit is mishandled operating _19 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 19 2009 12 9 14 56 21 TC T a E using advanced functions USING THE TURBO FUNCTION Turbo function will be helpful to cool or heat your room quickly and effectively by operating at the maximum fan speed for 30 minutes 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Turbo z button on the remote control until Turbo indicator appears on the remote control display The air conditioner operates in Auto fan speed and automatically adjusts the temperature according to the current room temperature The unit operates for 30 minutes and then operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used iY Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry Fan mode operating mode changes to Auto To deactivate Turbo function 1 Press the Turbo g button on the remote control while Turbo function is on The air conditioner operates in last used mode or in Auto mode if Dry Fan mode is most recent mo
31. pacity can be reduced depending on the temperature condition If the cooling operation is used at over 32 C indoor temperature it does not cool at its full capacity appendix _31 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 31 2009 12 9 14 56 59 QUESTIONS OR COMMENTS COUNTRY CALL ARGENTINE 0800 333 3733 BRAZIL 4004 0000 CHILE 800 SAMSUNG 7 26 7864 Nicaragua 00 1800 5077267 Honduras 3800 7919267 COSTA RICA 0 800 507 7267 ECUADOR 1 800 10 7267 EL SALVADOR 800 6225 GUATEMALA 1 800 299 0013 JAMAICA 1 800 234 7267 PANAMA 800 7267 PUERTO RICO 1 800 682 3180 REP DOMINICA 1 800 751 2676 TRINIDAD amp TOBAGO 1 800 SAMSUNG 726 7864 VENEZUELA 0 800 100 5303 COLOMBIA 01 8000112112 3030 8282 INDIA 1800 110011 1800 3000 8282 INDONESIA 0800 112 8888 MALAYSIA 1800 88 9999 1 800 10 SAMSUNG 726 7864 PHILIPPINES 1 900 8 SAMSUNG 726 7864 02 5805777 SINGAPORE 1800 SAMSUNG 726 7864 paba aag RING VIETNAM 1 800 588 889 SOUTH AFRICA O860 SAMSUNG 726 7864 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 32 OR VISIT US ONLINE AT www samsung com ar www samsung com br www samsung com cl www samsung com latin www samsung com latin www samsung com latin www samsung com atin www samsung com latin www samsung com latin www samsung com atin www samsung com atin www samsung com atin www samsung com latin www samsung com atin www samsung com atin www samsung com co www samsung com in www samsung com id www s
32. pping from the air flow blades Remote control is not working Check if the air conditioner has been cooling for an extended period of time with the air flow blades pointed downwards Condensation may generate due to the difference in temperature Check if your batteries are depleted Make sure batteries are correctly installed Make sure nothing is blocking your remote control sensor Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves 30 appendix Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 30 2009 12 9 14 56 59 TC T a OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use OPERATIONAL TEMPERATURE INDOOR MODE IF OUT OF CONDITIONS INDOOR OUTDOOR HUMIDITY Condensation may occur on COOLING 16 C to 32 C 15 C to 43C aries oe U ene m either water blow off or drops on Z the floor o 7 T HEATING 27 C or less OC to 24 C i Internal protection triggers and the air conditioner will stop Condensation may occur on DRYING 18 C to 32 C 15 C to 43 C i the indoor unit with risk to have either water blow off or drops on the floor 4 The standardized temperature for heating is 7 C If the outdoor temperature drops to O C or below the heating ca
33. r lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Young children should be supervised to ensure that they do not play with the appliance safety information 07 Brazil AQ09R IB HP 31238A E 11 19 09 indd 7 2009 12 9 14 55 16 CEER e Ww satety information CAUTION SIGNS CONT D CAUTION Inspect the condition electric connections pipes and external case of the air conditioner regularly by a qualified service technician Do not open doors and windows in the room being cooled during operation unless necessary Do not block the air conditioner vents If objects block the air flow it may cause unit malfunction or poor performance Make sure there are no obstacles under the indoor unit e Potential risk of fire or loss of property The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people or things For this reason where it is not observed as indicated into the Installation M
34. ration shown above depending on your model 10_ viewing Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 10 2009 12 9 14 55 18 OPENING THE FRONT PANEL Tightly grab front side of the front panel and lift up the panel to open Then slightly push the panel up until the panel is hanged over the hooks of the unit PINAG _ SS z aa HSITONA Power button and Room temperature sensor You may find the Power button on the right bottom side of the air conditioner If the front panel is open you can check the room temperature sensor You can turn on the air conditioner without the remote control by pressing the Power l button The room temperature sensor measures indoor room temperature A Make sure room temperature does not get damaged CAUTION Room temperature sensor CA Power l button CHECKING THE OUTDOOR UNIT AQ12U Series AQ18U Series Air Inlet Rear Air Inlet Rear a S Connection Valve gy H Air Outlet Pg Connection Valve 4 Air Outlet Air Inlet Rear Connection Valve Air Outlet viewing 11 Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 11 2009 12 9 14 55 42 a E VIEWING your alr conditioner CHECKING THE REMOTE CONTROL You can activate the air conditioner by pointing the remote control
35. reaches desired value heating will stop for a while e Each time you press the Fan lt or gt button fan speed will change in order of Auto Low Medium and High e Fan may not operate for about 3 5 minutes at the beginning to prevent any cold blasts while the air conditioner is warming up e Air flow can be adjusted manually see page 19 for instructions e Since the air conditioner heats the room by taking heat energy from outdoor air the heating capacity may decrease when outdoor temperature is extremely low Use an additional heating appliance in combination with the air conditioner if you feel the air conditioner heats insufficiently 18_ operating Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 18 2009 12 9 14 50 16 TC T a E ADJUSTING THE AIR FLOW DIRECTION Air flow can be directed to your desired position Vertical air flow Air flow blades move up and down 1 Press the Air swing button on the remote control Air swing indicator will be on and air flow blades move up and down continuously to circulate m the air O a Press the Air swing 5 button on the remote control again to keep the air flow direction in a uh constant position Auto SET TEMP Lic Pal Horizontal air flow Make sure one of the blade pin lever that stick out of the air flow blades are not broken 1 Move the blade pin lever left or right to keep the air fl
36. tential risk of fire or unit malfunction and there are risk of personal injury because unit may fall down Do not spray water directly on the air conditioner or use benzene thinner or alcohol to clean the surface of the unit e Potential risk of electric shock or fire e Potential risk of damage to the air conditioner Do not place any objects especially containers with liquid 06 safety information Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 6 2009 12 9 14 55 14 a Do not touch the pipe connected to the air conditioner Install the indoor unit away from lighting apparatus using the ballast e f you use the wireless remote control reception error may occur due to the ballast of the lighting apparatus Install the outdoor unit where operating noise and vibration will not disturb your neighbor and in a well ventilated area with no obstacle e Potential risk of malfunction e Operating noise may disturb your neighbor m Make sure that there are no obstacles or covers that block the air 5 conditioner bag NOE I Allow sufficient space for air circulation e Insufficient ventilation may result in poor performance If the power cable is damaged the manufacturer or a qualified service technician must replace it If a power outage occurs while the air conditioner is working turn off the power source immediately Max current is measured according to IEC standard for safety and current is measured accor
37. to change the time setting while Off timer indicator is Pal blinking You can set the time up to 12 hours increasing in CEL JX 30 minute unit up to first 3 hours and in hourly unit after ci first 3 hours a oe ae 4 Press the Set Cancel button on the remote control to active it Cai ON SET TEMP c KO The remote control display will show the hour s you have set for 3 seconds and set desired temperature will display When the set time has elapsed the air conditioner will automatically turn off and then good sleep indicator disappears If good sleep mode is not set within 10 seconds the air conditioner will end setting e Temperature Fan speed Air swing can be adjusted after setting good sleep in Heat mode e Temperature can be adjusted and the air conditioner automatically adjusts the Fan speed Air swing after setting good sleep in Cool mode e f you press the Mode button while the good sleep mode is on it will cancel the mode 24_ using advanced functions Brazil AQO9R_IB_HP_31238A_E_11 19 09 indd 24 2009 12 9 14 56 42 TC T a E Temperature changes in good sleep mode To prevent excessive cooling heating during sleep the good sleep mode automatically modifies the temperature setting in accordance with the time setting Temperature and air current change according to the three stages Fall asleep Sound sleep and Wake up from good sleep m
38. y Check if the circuit breaker is switched off Check if there is a power failure Check your fuse Make sure it is not blown out The temperature does not change Check if you selected Fan mode Press the Mode button on the remote control to select another mode The cool warm air does not come out of the air conditioner Check if the set temperature is higher lower than the current temperature Press the Temp A or V button on the remote control to change the set temperature Press the Temp A or V button to increase or decrease the temperature Check if the air filter is blocked by dirt Clean the Air filter every two weeks Check if the air conditioner has just been turned on If so wait 3 minutes The fan speed does not change Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan speed to Auto in Auto Dry mode Timer function does not set Odors permeate in the room during operation Check if you press the Set Cancel button on the remote control after you have set the time Check if the appliance is running in a smoky area or if there is a smell entering from outside Operate the air conditioner in Fan mode or open the windows to air out the room The air conditioner makes a bubbling sound A bubbling sound may be heard when the refrigerant is circulating through the compressor Let the air conditioner operate in a selected mode Water is dri
Download Pdf Manuals
Related Search
Related Contents
TSS2 - Absolute Acoustics MANUAL DE INSTALAÇÃO E DE FUNCIONAMENTO Contenido Sony Ericsson K790i Electrolux 55LXa Cooktop User Manual mode d`emploi - franqais . . . . . . . . . . . . . . . . . . . . 1 Copyright © All rights reserved.
Failed to retrieve file