1. 3 2 Pull the lower part of the front panel slightly forward below three inches 3 3 Lift the front panel upward Applying excessive force to remove the front panel may cause damage to the tab be sure not to use excessive force 4 Remove two screws on the lower right and left sides of the unit 5 Remove the chassis from the cabinet 6 Remove the rubber cap inserted into the basepan 7 Fix the drain pan as shown in the figure and then connect the drain hose You can use any commercially available drain hose 8 Install the cabinet at the specified area after installing the drain pan and then re assemble it in the original condition gt Secure the front panel to the case by replacing the screw removed in step 2 If a screw not removed in step 2 secure the panel with a supplied screw In the case of an area where the drain pan can be directly installed on the rear side of the unit after installing the air conditioner 1 Follow steps 6 and 7 only T 2 0 Z Drain Tube Screws 2EA RN 31 j Rubber cap Screw Drain Hose Bottom Side View with Drain Pan and Hose in Place THIS AIR CONDITIONER IS MANUFACTURED BY ESTE ACONDICIONADOR DE AIRE HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR ESTE APARELHO DE AR CONDICIONADO E FABRICADO POR QUESTO CONDIZIONATORE D ARIA E PRODOTTO D
2. two contacts should be no less than 3 5mm Such means for disconnection must be incorporation in the fixed wiring Before throwing out the device it is necessary to pull back the battery cells and get rid of them safely for recycling reasons When you need to dispose of the unit consult your dealer If pipes are removed incorrectly refrigerant may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environments Please recycle or dispose of the packaging material for this product in an environmentally responsible manner Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency T 2 0 gt Contents PREPARING YOUR AIR CONDITIONER m Safety Precautions s isecen ss seters sest s 2 m Air Conditioning Unit Main Parts and Control Panel 4 OPERATION YOUR AIR CONDITIONER Ti Cooling Your ROOM ceresna 5 m Airing Your Room m Switching the Air Conditioner Of 6 m Adjusting the Air Flow Direction Horizontally 7 m A
3. 5 Wipe the surface of the unit with a neutral detergent and then wipe it again with dry cloth Be sure not to use benzene solvent or other chemical products The air conditioner has two or three grille grooves depending on the model gt If you Then Will not be using the 4 Set the operating mode selection dial air conditioner for a to LOW and let it run of a few long period of time hours to dry the inside of the air conditioner thoroughly V Switch the air conditioner off and unplug it from the wall socket V Clean the filter and outer surfaces Have not used the air Set the operating mode selection dial conditioner for a long to LOW FAN and let it run of a few period of time hours to dry the inside of the air conditioner thoroughly Solving Common Problems Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary call PROBLEM EXPLANATION SOLUTION The air conditioner does not operate at all Check that the circuit breaker used for the air conditioner has not been triggered Check that the power cable is plugged into a wall socket and the socket is switched on if necessary Check that the correct operating mode has been selected cooling or airing The air conditioner does not cool Check that the correct operating mode has been selected The room temperature may be too low
4. A a ELECTRONICS
5. Dust may be blocking the air filter refer to page 9 cleaning instructions Check that there is no obstacle blocking the air flow into or out of the unit The air flow direction does not change when you set the air flow blade swing switch to the on position Odours are permeated in the room during air conditioning Check that the air conditioner has been switched on if necessary turn the operating mode selection dial refer to page 7 Air the room x 5 0 Z LU Technical Specifications Design and specifications are subject to change without notice Model Power Supply rr AA 115V 60Hz xxxxxx BA BB BC BD 220V 230V 60Hz 230 208V 60Hz sxxx DA 200 220V 50Hz 220 240V 50Hz Installation for 60Hz 1 Electrical Requirements For personal safety This appliance must be properly grounded V Do not under any circumstances cut or remove the third grounding prong from the power cord We recommend that you do not use an extension cord or an adapter plug with this appliance V Do not change the plug on the power cord of this appliance Follow national electrical codes or local codes and ordinances 115V 230V 208V 230V 208V 230V 208V 15 AMP Circuit 20 AMP circuit 15AMP circuit 30 AMP circuit parallel type perpendicular type tandem type tandem type If the electric supply provided does not meet the above
6. OWNER S INSTRUCTIONS MANUAL DE INSTRUCCIONES MANUEL D UTILISATION MANUAL INSTRUCOES ISTRUZIONI PER L USO AWO7P1HBA AWOSP1HBA AWO7P1HEA AWO9P1HDA AWO9P1HAA AWO9P1HEA AW12P1HAA AW12P1HEA AW12P1HBA AWT12P1HBA AW12P1HDA AWT12P1HEA AW14P1HBA AW24P1HBA BB BC BD AW18P1HEA AW24P1HEA EB AW18P1HBA AWT18P1HEA EB AWT24P1HEA EB EC Window type Room Air Conditioner Cool Acondicionador de airea dom stico sistema de tipo ventana Reirigeracion Climatiseur de type Fen tre Refroidissement 0 ar Condicionado de Window Type Refrigeracc Condizionatore d aria per ambienti da finestra Raffreddamento DODAO DB98 20383A 2 ITALIANO PORTUGU S FRAN AIS ESPA OL ENGLISH Register your product at www samsung com global register Safety Precautions The following safety precautions must be taken when using your air conditioner WARNING DURING OPERATION DISPOSING OF THE UNIT OTHERS Risk of electric shock e Can cause injury or death e Disconnect all remote electric power supplies before servicing installing or cleaning This must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard Users of this product are cautioned not to attempt repair of this product at their own discretion Instead they are requested to directly contact a designated service center or the outlet at which the product was purchased Never spill any kind of liquid into the unit Should this h
7. air flow blades on the right hand side of the unit thus increasing the efficiency of the air conditioner 1 Set the air flow blade swing switch to the on position Off On Result The inner blades swing automatically left and right B Air Swing 2 To stop the blades moving left and right set the air flow blade swing switch to the off position gt To stop the blades in a specific position and orient the air flow in off On the corresponding direction simply set the switch to the off Air Swing position when the blades are in the desired position Adjusting the Air Flow Direction Vertically Again depending on the position of the unit in your room you can adjust the orientation of the outer air flow blades on the right hand side of the unit RECOMMENDATION When Adjust the blades to face Cooling Upwards Adjust the air flow blades to the desired position by pushing them upwards or downwards gt If you orient the air flow blades downwards and the unit operates in Cool mode for long periods of time dew may Form on the surface of the blades Drip from the blades Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used LOOM SAX Mode Indoor Temperature Outdoor Temperature Indoor Humidity Cooling 21 C to 32 C approx 21 C to 43 C approx 80 or less If the air conditioner is used at Then Higher te
8. appen unplug or main switch off the unit and contact an authorized service center Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit Do not place any obstacles in front of the unit Do not spray liquid of any kind into the indoor unit Should this happen switch off the breaker used for your air conditioner and contact your installation specialist Make sure that the unit is correctly ventilated at all times Do not place clothing or other materials over it If the wireless remote control will not be used for a long time remove the batteries If applicable When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If applicable The air conditioner must be plugged into its own specific power source which must be installed in compliance with national wiring earthing and safety regulations If the power cord is damaged in any way it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard This device must be installed according to the national electrical rules The appliance must be installation that the plug should be easily accessible after installation If the fuse on PC board is broken please change it with the type of T 3 15A 250V The breaker of the air conditioner should be all pole switch and the distance between its
9. djusting the Air Flow Direction Vertically 7 RECOMMENDATIONS FOR USE m Temperature and Humidity RANGES 2 ccc 7 m Cleaning Your Air Conditioner o oo 8 m Solving COMMON Problems 9 m Technical Specitications 444444 10 Y INSTALLATION nasi 11 The illustrations in the step by step procedures use four different symbols gt IMPORTANT NOTE CAUTION The high inrush current of the starting compressor motor can have adverse effects to the operation of other equipment under unfavorable mains conditions This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker Before connection this equipment to the power supply system please report to your suply authority and obtain the consent Do not connect other electric appliances to the same supply lines AW18 The maximum permissible system impedance at the power junction box is 0 24 ohms Usually the maximum permissible mains impedance will not be exceeded when the branch to the power outlet is fed from a junction box with a rated current of 32A Air Conditioning Unit Main Parts and Control Panel The desing and shape are subject to change according to the model Air Outlet Inner air fl
10. ee the illustration below V The appliance must be fixed well by screw or similar method Awning 00 O 0006 Fence wall or other obstacle 009 Oo ja MODEL A AW07 AWO9 145 750mm 150mm min AW12 AWT12 170 AW14 AW18 AW24 260 AWT18 AWT24 260 00080 00 00080 2960 00 05 0064 090 GOS O0800 9 9 0 000 00 00 00500500C 502 00 0009300500 O oC gt Ifthe wall is greater than 150mm thick cut the wall back on a 45 angle if possible 100mm or more Installation of the Drain Tube Fix the drain tube as shown in the figure Installation of the Drain Pan The procedure for installing the drain pan should be determined by the condition of the installing area In the case of an area where the drain pan can not be directly installed on the rear side of the unit after installing the air conditioner Example High storage 1 Open the front grille refer to page 9 2 Remove the screw located at the lower section of the front grille It is secured in the C gt section depending on the model 3 Remove the front panel 3 1 Press both sides of the cabinet in the direction of the arrow as shown in the figure
11. mperature The automatic protection feature may be triggered and the air conditioner stopped Lower temperature A water leakage or some other malfunction may happen if the heat exchanger freezes Higher humidity levels Water may condense on and drip from the surface of the unit if it is used for long periods Cleaning Your Air Conditioner Be sure to clean the air filter periodically to maintain the air conditioner in the best condition for a long period of time PORTANT When cleaning the air conditioner turn it off and pull out the power plug 1 Hold the front grille handle slightly pull it to the left side and open the front grille gt The removal of the front grille makes it easier to clean the air conditioner Open the grille as much as possible GAUTION Removal and reassembly of the Front Grille 1 Grasp the lower part of the front grille and the front grille handle then open the grille The open angle of front grille has not to be exceeded 25 degree 2 Lift the front grille slightly and remove it from the front panel 3 Reassembling of front grille should be done in reverse order of disassembly Front grille 2 Pull the air filter to the right side Grille groove Body guide 3 Remove all dust on the air filter with a vacuum cleaner or brush 4 When you have finished insert the air filter back into its original position
12. ow blades right left orientation AMM AMM Outer air flow blades up down orientation Air inlet Inside The air filter is located in side Air inlet Outside SSS Ventilation lever S SSS Power Cable me The type of the power plug SSS D may differ according to the V type of local power supply Low Fan YN e 8 Temperature control dial Operating mode selection dial 9 Low Cool 9 Med Cool Operation Off Air Swing Air flow blade swing switch Cooling Your Room You must select the Cool mode if you wish to lower the temperature in your room Y ou can also set the fan speed 1 Select the operating mode and fan speed To cool your room with a Set the operating mode selection dial to High fan speed HI COOL Between HIGH and LOW MED COOL Low fan speed LOW COOL Result 9 The air conditioner starts up in Cool mode The fan starts up at the speed selected gt You can change modes at any time 2 adjust the temperature turn the temperature control dial to the desired position Possible temperatures Between 18T and 29 inclusive Result The air conditioner starts cooling if the room temperature is higher than the selected temperature 3 To control the direction of the air flow refer to page 7 I o gt LU OFF Lo
13. specifications call a licensed electrician Aluminum house wiring may pose special problems consult a qualified electrician This unit requires a separate circult serving only this appliance Installation Before installation be sure to check the installation area for the air conditioner and drain hose Checkpoints prior to installation 1 Check the cabinet and front grille of the unit for any harmful defects such as scratches 2 Be sure to check the power supply Refer to the specifications on the label attached to the unit Installation Conditions 1 As the unit is heavy the wall or window of the installation area should have sufficient strength and durability for operation of the air conditioner and for prevention of any vibration or noise If it is weak reinforcement work should be performed separately 2 It is advisable to install the air conditioner in the north or west side to prevent the effect of direct sunlight When installing it in the south or east side due to unavoidable circumstances it is advisable to install the sunshade to prevent the direct sunlight In this case take care not to cause any hindrance to the flow of outside air 3 When installing the air conditioner be sure to obtain sufficient space on the rear side of the unit for smooth flow of air When operating the air conditioner in closed areas such as inner building with cooling operation and result in trouble with the unit S
14. w Fan Hi Fan 9 9 9 9 Low Cool Hi Cool 9 Med Cool Operation 27 0 23 C 5 6 4 7 E 8 ac 3 230 27C 18C 2 9 1 10 Thermostat Airing Your Room If the atmosphere in your room is stale you can air it using the Fan feature and if necessary evacuate the stale air outside 1 If you wish to evacuate stale air outside push the ventilation lever on the front of the unit to the right and the open position Result The air inside the room circulates and stale air is evacuated outside Otherwise push the ventilation lever to the left and the closed position Result The air simply circulates inside the room OFF Low Fan Hi Fan 9 9 Set the operating mode selection dial to the HI FAN or LOW position gt HI FAN The fan turns rapidly LOW FAN The fan turns slowly Low Cool Hi Cool Result The air conditioner starts up in Fan mode Med Cool Operation 3 control the direction of the air flow refer to page 7 Switching the Air Conditioner Off You can switch the air conditioner off whenever you want 1 switch the unit off simply set the operating mode selection dial OFF to the OFF position Low Fan Hi Fan 9 Result The air conditioner stops operating 9 9 Low Cool Hi Cool 9 Med Cool Operation Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room you can adjust the orientation of the inner