1. e Deodorizing filter can be placed in any 4 slots beneath the air filter e Front panel of your air conditioner is actually not detachable 4 Install the new Deodorizing filter back in position 5 Close the front panel Grab the side of the front panel tightly and push it downward e The replacement timing of the Deodorizing filter differs depending on usage and environmental conditions e Even if Deodorizing and Anti allergy filters are installed in an inverted position it will not affect its filtration system cleaning and maintaining _31 cleaning and maintaining tne alr conaltioner MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time dry the air conditioner to maintain it in best condition 1 Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug There may be internal damage if moisture is left in components 2 Before using the air conditioner again dry the inner components of the air conditioner again by running in Fan mode for 3 to 4 hours This helos remove odors which may have generated from dampness Periodical checks Refer to the following chart to maintain the air conditioner properly Type Description Monthly Sha Cees Clean the air filter 1 Clean the condensate drain pan 2 Indoor uni
2. Power button and Room temperature sensor You may locate the Power button on the right bottom side of the air conditioner If the front panel is open you can check the room temperature sensor You can turn on the air conditioner without the remote control by pressing the Power button The room temperature sensor measures indoor room temperature Room temperature KE sensor ma Power l button Front panel of your air conditioner is actually not detachable viewing _11 HSITONA VIEWING your alr conditioner CHECKING THE REMOTE CONTROL You can activate the air conditioner by pointing the remote control away from it When using the remote control always point it directly at the air conditioner Remote control display R Temperature V A l Powe ro Decrease Increase the temperature Turn on off the air conditioner by 1C O NG di Fan speed O Adjust how much air flows through the air conditioner with the Fan Speed 4 different fan speeds such as Mode Set one of the 5 operating modes See pages 14 18 for instructions Cy Auto Low Medium High Digital 7 On Off Set to turn on off the digital display of the unit during operation Operating mode pigtatiowot 5 indicator still remains on CD Air swing po Activate Deactivate air flow
3. pi T of electronic wire Power Earth Communication remot 242V X A 30MMA h Decide the capacity of ELCB or MCCB ELB by below formula The capacity of ELCB or MCCB ELB X A 1 25 X 1 1 X DAI X The capacity of ELCB or MCCB ELB 2 Ai Sum of Rating currents of each indoor unit Refer to each installation manual about the rating current of indoor unit Decide the power cable specification and maximum length within 10 power drop among indoor units Coefx35 6XLkxik lt 10 input voltage V 1000XAk k 1 Coef 1 55 Lk Distance among each indoor unit m Ak Power cable specification mm ik Running current of each unit A Indoor Unit Setting 1 Before installing the indoor unit assign an address to the indoor unit according to the air conditioning system plan 2 The address of the indoor unit is assigned by adjusting MAIN SW01 SWO2 and RMC SWO3 SW04 rotary switches SW01 SW02 SW03 SW04 SL ON Cover PCB SW05 SW06 SW07 Fegaliteealtaes Setting MAIN Address The MAIN address is for communication between the indoor unit and the outdoor unit Therefore you must set it to operate the air conditioner properly You can set the MAIN address from 00 to 99 by mixing SW01 and SWO2 The MAIN address from 00 to 99 should differ from each other Check the indoor unit address on the plan that you are to i
4. iS These warning signs are here to prevent injury to you and others Please follow them carefully After reading this section keep it in a safe place for future reference safety information _03 satety information SEVERE WARNING SIGNS WARNING N Do not place the air conditioner near hazardous substances or equipment that releases free flames to avoid fire explosions or injuries e Potential risk of fire hazard or explosion Do not install the outdoor unit at an unstable place or elevated surface where there is potential risk of falling e f the outdoor unit falls it may cause personal injury or loss of property Failure or damage may occur if any changes or modification that is not stated in the installation manual was performed In this case user will be responsible for the repair expenses Install the air conditioner away from direct exposure to sunlight heating apparatus and humid places e Hang curtains on windows to boost cooling efficiency and to avoid the risk of electric shock Do not cut the power plug and connect to a different power cable Do not yank the power cable and touch the power plug with hands e Potential risk of fire or electric shock Never use a damaged or dusted power plug power cable or loosened power receptacle e Potential risk of fire or electric shock Install an exclusive circuit breaker and short circuit breaker for the air conditioner e Potential risk of el
5. USING THE EVAPORATOR CLEAN FUNCTION Evaporator clean function will prevent from growing mold by eliminating the moisture inside of the indoor unit Your indoor unit evaporates the moisture inside of the unit Activate this function to provide you with more clean and healthier air 1 Press the Evap CLEAN EJ button gt When the air conditioner is turned off The Evaporator clean indicator on the indoor unit display appears and the Evaporator cleaning function runs gt When the air conditioner is turned on The Evaporator clean indicator on the indoor unit display appears and the Evaporator cleaning function runs after stopping the air conditioner operation Evaporator Cleaning time can vary depending on the previously used mode Auto cool Cool Dry mode approximately 30 minutes Auto heat Heat Fan mode approximately 15 minutes When the air conditioner is turned on the Auto cleaning function runs after stopping the air conditioner operation Set Temp Auto 28 using advanced functions cleaning and maintaining tne alr conaltioner CLEANING THE EXTERIOR 1 Wipe the surface of the unit with a slightly wet or dry cloth when needed HSINONI Do not use Benzene Thinner or Clorox caution hey may damage the surface of the air conditioner and can create a risk of fire CLEANING THE FILTER When cleaning the filter make sure to unplug the power from the unit No s
6. Simply set the time and your air conditioner will turn on off automatically On timer This function allows you to turn on the air conditioner automatically within the time range of 24 hours On timer is available while your air conditioner is on off 1 Press the On button on the remote control Set Temp Auto On timer indicator blinks on the remote control display HSITSNA amp BIL X LI lar Timer good Up Set Cancel sleep 2 Set the time you want the air conditioner to turn on automatically Set Temp Auto Press the Up or Down button on the remote control to change the time setting while On timer indicator is blinking You can set the time up to 24 hours increasing opp in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours wag good Up Set Cancel sleep j o 3 Press the Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set The air conditioner will operate automatically at set time and then On timer indicator disappears If On timer is not set within 10 seconds the air conditioner will end setting 4 Set the operating mode Press the Mode button on the remote control until the desired mode appears on the remote control display Set Temp AutoCoolDry The air conditioner will operate in the mode you set o 3r A T Lin On timer functi
7. blade T Wa t an movement automatically up and urbo Ro down Operate in maximum fan speed to cool warm quickly l l Evap CLEAN Energy saving function DA Evaporator clean function Dry Less energy usage makes your inside of the indoor unit to get rid of space cool between the odor temperature range of 26 C 30 C mpizone function Timer function pizone Clean Mode l n O On Off On Off Emit hydrogen H and oxygen O Set the timer on off in the air to remove polluted substances such harmful Up Down particles Increase Decrease the time Clean Mode Set Cancel Set one of the 3 mpizone Set Cancel the current operating types timer good sleep mode setting good sleep Set the good sleep mode on off Each time you press the button a short beep will sound and a transmit indicator appears on the remote control display 12 viewing Remote control display a Set temperature Air swing indicator indicator Operating mode I mpizone indicator mpizone indicator Rapid AutoSilence Set Temp AutoCoolDry YO Turbo indicator j FanHeatTurb Fan speed indicator E Saver Sisa Energy saving indicator HSITON3I good sleep indicator D LIL Transmit indicator Sleep K O Cid O Tur PM Low battery Indicator On Off Timer indicator Using the remote control e Point the remote control towards the remote control sensor of the unit e When properly pre
8. control to active it on The remote control display will show the hour s you have set The air conditioner will turn off automatically at set time and then Off timer indicator disappears If Off timer is not set within 10 seconds the air conditioner will end setting iY e Setting time allows you to change by pressing the Off button Press the Up or Down button to change the time setting and then press the Set Cancel button to active it on e You can combine Off timer function with On timer function to turn on and then off the air conditioner at the desired time See page 23 for instructions To deactivate the Off timer 1 Press the Set Cancel button on the remote control Off timer you set will be canceled and Off timer indicator will disappear 22 using advanced functions Combining On timer and Off timer You can combine the On timer and Off timer together for more convenient use of the timer function 1 Set the On timer Press the On button ILI Set Temp Auto Set the time with Up and Down button Press Set Cancel button to activate the On timer tas L D Im On ar a a f Timer mg if See page 21 for more detail instructions on setting On a o F timer own ace E 2 Set the Off timer Press the Off button Set the time with Up and Down button Press Set Cancel button to activate the Off timer When you set the time there can be two possible options On timer is shorter than
9. information 07 satety information For use in Europe This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision CAUTION SIGNS CONT D Inspect the condition electric connections pipes and external case of the air conditioner regularly by a qualified service technician Do not open doors and windows in the room being cooled during operation unless necessary Do not block the air conditioner vents If objects block the air flow it may cause unit malfunction or poor performance Make sure there are no obstacles under the indoor unit e Potential risk of fire or loss of property The air conditioner should be used only for the applications for which it has been designed the indoor unit is not suitable to be installed in areas used for laundry Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs The units components must be accessible and that can be disassembled in conditions of complete safety either for people
10. mode 1 Press the mpizone On Off button on the remote control mpizone mode you set will be canceled and blue light will turn off 26_ using advanced functions USING THE ENERGY SAVING FUNCTION This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode 1 Press the Energy saving DA button on the remote control while the air conditioner is operating in Cool mode Set Temp Cool E Saver indicator and air swing indicator appear O ew IE automatically on the remote control display The air flow blades move up and down E Saver If the current set temperature is lower than 26 C it will automatically raise to 26 C HSITONA K e Energy saving function is only available in Cool mode e When Energy saving function is activated temperature range will be limited to 26 C 30 C e f the desired temperature is lower than 26 C turn off the energy saving function by pressing the Energy saving DA button again e Temperature Fan speed can also be adjusted See step 3 4 on page 15 for instructions e Air flow can be adjusted manually See page 19 for instructions To deactivate the Energy saving function 1 Press the Energy saving DA button on the remote control Energy saving function you set will be canceled and Energy saving indicator will disappear on the remote control display using advanced functions _27 using advanced functions
11. or things For this reason where it is not observed as indicated into the Installation Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation won t be considered in warranty and charged to end user Ensure the off on and protection switches are properly installed Do not use the air conditioner if damaged If problems occur immediately stop operation and disconnect the plug from the power supply If the air conditioner will not be used for an extended period of time for example over several months unplug the power from the wall Call the place of purchase or a contact center if repairs are needed e Potential risk of fire or electric shock if disassembly or repairs are attempted by a non qualified service technician 08_ safety information contents VIEWING YOUR AIR CONDITIONER OPERATING BASIC FUNCTION USING ADVANCED FUNCTIONS CLEANING AND MAINTAINING THE AIR CONDITIONER APPENDIX INSTALLING YOUR AIR CONDITIONER E 10 10 10 11 11 12 18 13 13 14 14 14 15 16 17 18 19 19 19 20 21 21 22 23 24 26 27 28 29 29 29 30 31 31 32 32 33 34 35 36 Checking the indoor unit and digital display Main parts Indoor unit digital display Removing the front panel Power button and Room temperature sensor Checking the remote control Remote control display Using th
12. 067207884 URUGUAY 000 405 437 33 www samsung com INDIA 1800 30006282 www samsung com in PARAGUAY 009 800 542 0001 www samsung com py 1800 266 8282 SRL 0800 124 421 Demais cidades e regides b www samsung com br LUXEMBURG 261 03 710 www samsung com 4004 0000 Capitais e grandes centros g MONTENEGRO 020 405 888 www samsung com 800 SAMSUNG 726 7864 CHILE www samsung com cl NETHERLANDS 0900 SAMSUNG 0900 7267864 0 10 Min www samsung com HHP 02 24828200 NORWAY 815 56480 www samsung com BOLIVIA 800 10 7260 www samsung com 0 801 172 678 lub 48 22 607 93 33 01 8000 112 112 COLOMBIA www samsung com co HHP 0 801 672 678 lub 48 22 607 93 33 Bogota 6001272 POLAND catkowity koszt po czenia jak za 1 impuls www samsung com pI i i www samsung com latin Spanish wed ug taryfy operatora COSTA RICA 0 800 507 7267 9 p www samsung com latin_en English 4 koszt po czenia wed ug taryfy operatora www samsung com latin Spanish PORTUGAL 808 20 SAMSUNG 808 20 7267 www samsung com DOMINIC TERO Va epe www samsung com latin_en English 08008 SAMSUNG 08008 726 7864 www samsung com latin Spanish ROMANIA www samsung com ro ECUADOR 1 800 10 7267 i 9 p TOLL FREE No Cu oop ieee www samsung com latin_en English SERBIA 011 321 6899 www samsung com rs i f EL SALVADOR 800 6225 a Ba oA ma SLOVAKIA 0800 SAMSUNG 0800 726 786 www samsung com aai Na EN SPAIN 902 1 SAMSUNG 902 172 678 www samsung com GUATEMALA 1 800 299 00
13. 13 Hniywsat SUNG Eoin Spanish www samsung com latin_en English SWEDEN 0771 726 7864 SAMSUNG www samsung com Jatin Spanish www samsung com ch German PA DRIA AANE ERT aa aa SWITZERLAND 0848 SAMSUNG 7267864 CHF 0 08 min ALA a aa www samsung com ch fr French JAMAICA 1 800 234 7267 www samsung com U K 0330 SAMSUNG 7267864 www samsung com Pe NICARAGUA 00 1800 5077267 O eO BaN EIRE 0818 717100 www samsung com www samsung com latin_en English LITHUANIA 8 800 77777 www samsung con lt PANAMA 800 7267 Aan sarau i on latin Spanish www samsung com latin en English LATVIA 8000 7267 www samsung com Iv 0 800 777 08 ESTONIA 800 7267 www samsung com ee PERU Desde celulares por favor llamar al numero www samsung com pe RUSSIA 8 800 55 5 55 55 www samsung com 336 8686 GEORGIA 0 800 555 555 WN WSA MSUN J CON PUERTO RICO 1 800 682 3180 www samsung com ARMENIA 0 800 05 555 www samsung com TRINIDAD amp 1 800 SAMSUNG 726 7864 www samsung com AZERBAIJAN 088 55 55 555 www samsung com TOBAGO KAZAKHSTAN 8 10 800 500 55 500 GSM 7799 www samsung com VENEZUELA 0 800 100 5303 www samsung com ve UZBEKISTAN 8 10 800 500 55 500 www samsung com AUSTRALIA 1300 362 603 www samsung com au KYRGYZSTAN 00 800 500 55 500 www samsung com 1 800 10 7267864 PLDT TADJIKISTAN 8 10 800 500 55 500 www samsung com PHILIPPINES 1 800 8 7267864 Globe landline and Mobile www samsung com ph MONGOLIA 7 800 555 55 55 www samsung com MAAALA E Tanan BELAR 810 800 500 00 VWW
14. 26 7864 www samsung com BULGARIA 07001 33 11 share cost tariff www samsung com bg OMAN 800 SAMSUNG 726 7864 www samsung com ae English www samsung com ae ar Arabic CROATIA 062 SAMSUNG 062 726 786 www samsung com hr www samsung com ae English CZECH 800 SAMSUNG 800 726786 www samsung com KUWAIT 183 2255 183 CALL j 4 www samsung com ae_ar Arabic DENMARK 70701970 www samsung com www samsung com ae English BAHRAIN 8000 4726 i FINLAND 030 6227 515 www samsung com www samsung com ae_ar Arabic FRANCE 01 48 63 00 00 www samsung com fr QATAR 800 2255 800 CALL www samsung com ae English www samsung com ae_ar Arabic 0180 6 SAMSUNG bzw 0180 6 7267864 EGYPT 08000 726786 www samsung com HHP 0180 6 M SAMSUNG bzw 800 2227 GERMANY l www samsung com JORDAN X 3 www samsung com Levant English 0180 6 67267864 065777444 0 20 Anruf aus dem dt Festnetz aus dem SYRIA 18252273 www samsung com Levant English Mobilfunk max 0 60 Anruf IRAN 021 8255 www samsung com CYPRUS 8009 4000 only from landline www samsung com gr MOROCCO 080 100 2255 www samsung com GREECE 80111 SAMSUNG 80111 726 7864 only from land line 30 210 6897691 from mobile and land line MUSA SUN JCO JE SAUDI ARABIA 9200 21230 www samsung com sa Arabic HUNGARY 06 80 SAMSUNG 726 7864 http www samsung com hu TURKEY 444 77 11 www samsung com 800 SAMSUNG 726 7864 ARGENTINE 0800 333 3733 www samsung com ar ITALIA www samsung com BR SOO Wizainsuing 80
15. HSITONA using advanced functions USING THE mpizone FUNCTION MPI Micro Plasma lon zone generates hydrogen H and oxygen O to remove a polluted substance and decomposition of such harmful particles It makes you breathe better as if you were staying around waterfalls ocean surf rivers and mountains mpizone indicator on the indoor unit will fade in and fade out continuously when the mpizone function is activated 1 Press the mpizone On Off button on the remote control while the air conditioner off EIEI mpizone indicator will appear on the remote control T EI display The air conditioner generates MPI in mpizone Auto ya mode Pa Got Mpizone n On Off Clean Mode 2 Set the operating type Rapid AutoSilence Each time you press the Clean Mode button while the i air conditioner is off the operating type will change in order of Auto Silence and Rapid 5 5 Auto adjust the fan soeed automatically Silence operate at a minimum fan speed quietly Rapid operate at a maximum fan speed to clean and purifies the air effectively and quickly lean mosk Imer good On Up Set Cancel Sleep c Mpizone On Off Clean Mode 4 A The Clean Mode button will not work while the air conditioner is on 4 When you activate the mpizone function while the air conditioner is on mpizone function automatically sets to Auto To deactivate mpizone
16. Heat Mode Fan Speed O 3 Set the temperature Press the Temperature V or A button on the remote Set Temp control to decrease or increase the desired temperature H la Auto St Cc You can set the desired temperature between the range of 18 C 30 C You can decrease increase the temperature by 1 C K e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions O 16_ operating Fan Fan mode can be selected to ventilate your room Fan mode will be helpful to refresh the stale air in your room 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Fan mode indicator appears on the remote control display The air conditioner operates in Fan mode and automatically adjusts the temperature according to the Current room temperature CC if When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the fan speed Press the Fan Speed button on the remote control to set the desired fan speed ed ONA g 7 iY When you press the Fan Speed button fan speed will N T change in order of Low Medium and High K e When you are using the remote control make sure correct indicat
17. Off timer The air conditioner will turn on and then off automatically Set up should be done while the air Set TAG conditioner is off _ For example If the On timer is set at 3 hours and si z NI WC the Off timer at 5 hours the air conditioner will turn vizi Sr Cad Lar off automatically 3 hours after the set time and then operate for next 2 hours before turning off automatically Cy aw SS On timer is longer than Off timer The air conditioner will turn off and then on automatically Set up should be done while the air conditioner is operating Set Temp Auto For example If the On timer is set at 3 hours and Ju the Off timer at 1 hour the air conditioner will turn off n O opin llar Ot Ar On automatically an hour after the set time and remain off for 2 hours before turning on automatically Imer good Up Set Cancel sleep D 4 See page 22 for more detail instructions on setting Off own ee timer 7 To deactivate the timer combination 1 Press the Set Cancel button on the remote control Both of the On and Off timer will be canceled and the indicators will disappear using advanced functions _23 HSINONI using advanced functions SETTING TIMER good sleep mode good sleep mode allows you to set a comfortable sleep temperature while saving energy and having sound sleep good sleep mode can be set up when the air conditioner is on 1 Set the o
18. ak Test 8 Insulation Leak test LEAK TEST WITH NITROGEN before opening valves In order to detect basic refrigerant leaks before recreating the vacuum and recirculating the R410A it Fixing the Installation Plate s responsible of installer to pressurize the whole system with nitrogen using a pressure regulator at a pressure Before fixing the installation plate to the wall or window frame above 4 1MPa gauge you must determine the position of the 65mm hole through LEAK TEST WITH R410A after opening valves which the cable pipe and hose pass to connect the indoor unit Before opening valves discharge all the nitrogen into er eee AA PA the system and create vacuum After opening valves check leaks using a leak detector for refrigerant R410A When facing the wall the pipe and cable can be connected from the C D Right 0 Left Underside right Rear right or left me moo N x The designs and shape are subject a to change according to the model U U A CAUTION 1 Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards Discharge all the nitrogen to create a vacuum and charge the system If you fix the indoor unit to a Follow step s dl Insulation Wall 3 After checking for gas leaks in the system insulate the Window frame 4to6 p
19. conditioner is warming up 4 e Air flow can be adjusted manually See page 19 for instructions e Since the air conditioner heats the room by taking heat energy from outdoor air the heating capacity may decrease when outdoor temperatures are extremely low If you feel the air conditioner insufficiently heats using an additional heating appliance in combination with the air conditioner is recommended 18_ operating ADJUSTING THE AIR FLOW DIRECTION Air flow can be directed to your desired position Vertical air flow Air flow blades move up and down 1 Press the Air swing button on the remote control Air swing indicator will be on and the number of indicator lights move up and down Air flow blades move up and down continuously to circulate the air HSITSONA To keep the air flow direction in a constant position press the Air swing button on the remote control again Set Temp Auto JIL t Horizontal air flow Make sure one of the blade pins that stick out of the air flow blades are not broken 1 Move the blade pin lever left or right to keep the air flow direction in a constant position you prefer Be extremely careful with your fingers while adjusting the Horizontal air flow direction caron Nere is a potential risk of personal injury when the unit is mishandled operating _19 using advanced functions USING THE TURBO FUNCTION Turbo function will be helpful to cool or
20. crewdriver by turning it to the right until it fixes to the end of the groove 38 appendix Power and communication cable connection 1 2 220 240V Before wiring work you must turn off all power source Indoor unit power should be supplied through the breaker ELCB or MCCB ELB separated by the outdoor power ELCB Earth Leakage Circuit Breaker MCCB Molded Case Circuit Breaker ELB Earth Leakage Breaker The power cable should be used only copper wires Connect the power cablef1 L 2 N among the units within maximum length and communication cable F1 F2 each Connect V1 V2 for DC12V and F3 F4 for communication when installing the wired remote Control Outdoor F1 F2 Unit Wired Remote door Wit Indoor Unit3 Ka salz ior Unti 3x ELCB Essential Installation WARNING ndoor Unit 6 ndoor Unit5 ndoor Unit4 Power off before connecting any wires Indoor PBA will be damaged while V1 V2 F3 F4 short each other Selecting compressed ring terminal Norminal dimensions for cable Silver solder aa L Norminal K Decke Wand befestigte Inneneinheit dimensions Standard for screw dimension mm mm mm Standard dimension 4 6 6 1 5
21. ctions Temperature changes in good sleep mode To prevent excessive cooling heating during sleep the good sleep mode automatically modifies the temperature setting in accordance with the time setting Temperature and air current change according to the three stages Fall asleep Sound sleep and Wake up from good sleep mode and then the air conditioner will automatically turn off when the set time has elapsed Three stage good sleep prevents you from having difficulty sleeping in summer winter night Fall asleep Eases you into sleep by dropping the temperature Sound sleep Relaxes your body and raises your temperature slightly Wake up from good sleep mode Allows you to wake up from comfortable intermittent air and it makes you feel refresh e Set Off timer in good sleep mode over 5 hours You feel disturbed sleep if the good sleep is set too short or long because the default is set to 8 hour operation e f the good sleep mode is set less than 4 hours the operation will stop at the set time lf the good sleep mode is set over 5 hours it will run as Wake up stage for the last one hour before stop e Recommended set temperature is between 25 C 27 C for cooling and 21 C 23 C for heating To deactivate good sleep mode 1 Press the Set Cancel button on the remote control good sleep mode you set will be canceled and good sleep indicator will disappear using advanced functions _25
22. d e Make sure nothing is blocking your remote control sensor Check that there are strong lighting apparatus near the air conditioner Strong light which comes from fluorescent bulbs or neon signs may interrupt the electric waves 34 appendix OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within Refer to the table for efficient use MODE OPERATIONAL TEMPERATURE INDOOR OUTDOOR INDOOR HUMIDITY IF OUT OF CONDITIONS Condensation may occur on the indoor unit with risk to have COOLING 18C to 32 C 5 C to 43 80 or less either water blow off or drops on the floor HEATING 27 C or less 20 C to 24 C i Internal protection triggers and the air conditioner will stop Condensation may occur on DRYING 18 C to 32 C BC to 43 C i the indoor unit with risk to have either water blow off or drops on the floor K The standardized temperature for heating is 7 C If the outdoor temperature drops to O C or below the heating capacity can be reduced depending on the temperature condition If the cooling operation is used at over 32 C indoor temperature it does not cool at its full capacity Model specification Dimension and weight Dimension and weight Type Indoor unit Modi uom WxDxH mm Net weight kg 9 5 9 5 9 5 13 5 13 5 9 5 9 5 appendix _35 HSITSNA Installation Part Performing Le
23. e remote control Installing the batteries Turning the air conditioner on and off Selecting operation mode Auto Cool Dry Fan Heat Adjusting the air flow direction Vertical air flow Horizontal air flow Using the Turbo function Setting timer On timer Off timer Combining On timer and Off timer good sleep mode Using the mpizone function Using the Energy saving function Using the Evaporator clean function Cleaning the exterior Cleaning the filter Air filter Anti allergy filter Replacing the filter Deodorizing filter Maintaining your air conditioner Periodical checks Internal protections via the unit control system HSITONA Troubleshooting Operation ranges Installation part Correct Disposal of This Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office fo
24. ectric shock or fire Do not insert anything such as fingers or branches into the air conditioner vents while the air conditioner is running e Keep the children away from the air conditioner to prevent them from putting their finger on the air conditioner Potential risk of personal injury Ensure no water gets into the air conditioner e Potential risk or electric shock e f the water gets into the air conditioner stop and unplug the power source immediately Turn off the air conditioner using the provided remote control or control accessory if provided Do not unplug to turn off the unit unless there is an immediate danger Do not run the air conditioner for an extended period of time in a room with the door closed or with babies elderly or disabled people e Open the door or windows to ventilate your room at least once an hour to prevent oxygen shortage The air conditioner is composed of moving parts Keep children away from the unit to avoid physical injury 04 safety information N Make sure that children take precautions against access to the air conditioner and they do not play with the unit Do not clean the interior of air conditioner on your own e You may damage the parts which can cause electric shock or fire e Consult contact center for cleaning the interior of the air conditioner Do not connect the air conditioner with heating apparatus or attempt to disassemble remodel or repair it yourself e P
25. features of your new air conalitioner e Cool Summer Offer On those hot sweltering summer days and long restless nights there is no better escape from the heat than the cool comforts of home Your new air conditioner brings an end to exhausting hot summer days and lets you rest This summer beat the heat with your own air conditioner e Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer but can also be an efficient heating method in the winter with the advanced Heat pump system This technology is up to 300 more efficient than electrical heating so you can further reduce its running cost Now meet year round needs with one air conditioner e A Look for Everywhere The elegant and harmonious design gives priority to the esthetics of your space and complements any of your existing interior d cor With its soft color and rounded edge shape the new air conditioner adds class to any room Enjoy what your air conditioner offers both functionally and esthetically e mpizone mpizone function generates hydrogen H and oxygen O to attack undesirable air contaminants such as bacteria pollen and odor It makes you breathe better as if you were staying around waterfalls ocean surf rivers and mountains e good sleep function good sleep mode allows you to set a comfortable sleep temperature while saving energy and having sound sleep PSn1nsu nag For easy future refere
26. he air internal battery conditioner operates in Cool mode The air conditioner does not start operating immediately to protect the Protect compressor compressor of the outdoor unit after it has been started SZ If the heat pump is operating in Heat mode De ice cycle is actuated to remove frost from an outdoor unit that may have deposited at low temperatures The internal fan is switched off automatically and restarted only after the de ice cycle is completed cleaning and maintaining _33 appenak TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally This may save time and unnecessary expenses PROBLEM SOLUTION The air conditioner does not operate immediately after it has been restarted e Because of the protective mechanism the appliance does not start operating immediately to keep the unit from overloading The air conditioner will start in 3 minutes The air conditioner does not work at all Check that the power plug is properly connected Insert the power plug into the wall socket correctly e Check if the circuit breaker is switched off e Check if there is a power failure e Check your fuse Make sure it is not blown out The temperature does not change e Check if you selected Fan mode Press the Mode button on the remote control to select another mode The cool warm air does not come out of the air conditioner e Check if
27. heat your room quickly and effectively by operating at the maximum fan speed for 30 minutes 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Turbo z button on the remote control until Auto Cool HeatTurbo Turbo indicator appears on the remote control display The air conditioner operates in Turbo fan speed and automatically adjusts the temperature according to the current room temperature The unit operates for 30 minutes and then operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used 4 Turbo function is only available in Auto Cool Heat mode If Turbo function is selected in Dry Fan mode operating mode changes to Auto To deactivate Turbo function 1 Press the Turbo 2 button on the remote control again The air conditioner operates in last used mode or in Auto mode if Dry Fan mode is most recent mode used 4 e When you are using the remote control make sure corresponding indicator appears on the remote control display e Temperature Fan speed cannot be adjusted while using this function e Air flow can be adjusted manually See page 19 for instructions e When the Turbo function is activated pressing Mode button will automatically cancel the function 20_ using advanced functions SETTING TIMER This advanced Timer function allows you to turn on off your air conditioner automatically even when you are away
28. immediately and call a contact center e Potential risk of fire or electric shock CAUTION SIGNS CAUTION NI Do not block or place items in front of the air conditioner Do not step hang onto or place heavy items on the air conditioner e Potential risk of personal injury If failure or damage occurs on the conditions of improper use not followed by the installation manual there will be an extra labor charge for installing and construction e Potential risk of malfunction electric shock or fire if repairs or installations are attempted by a non qualified service technician Do not spray flammable gases such as insecticide near the air conditioner e Potential risk of electric shock fire or unit malfunction Do not open the front grille during operation e Potential risk of electric shock or unit malfunction Cool air should not flow directly towards people pets and plants e lt is harmful to your health pets and plants Do not drink drain water coming out of the air conditioner e Potential risk of health hazard Do not allow children to climb on the air conditioner Do not use the air conditioner as a cooling precision instrument for food pets plants cosmetics or machinery Do not pull or give excessive shock to the air conditioner e Potential risk of fire or unit malfunction and there are risk of personal injury because unit may fall down Do not spray water directly on the air conditioner or use ben
29. ipe hose and cables Then place the indoor unit on the installation plate 3 Fix the installation plate to the wall giving attention to the weight of the indoor unit 1 To avoid condensation problems place heat resistant polyethylene foam separately around each refrigerant pipe in Ifyou mount the plate to a concrete wall with anchor i y P the lower part of the indoor unit bolts the anchor bolts must not project more than 20 f di 2 Wrap the refrigerant pipe and the drain hose in the rear of 4 Determine the positions of the wooden uprights to be the indoor unit with the absorbent pad attached to the window frame Wind the pipe and hose three times to the end of the indoor unit with the absorbent pad 20mm interval 5 Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit f 3 Wind the pipe assembly cable and drain hose with 6 Attach the installation plate to the wooden uprights using insulation tape tapping screws as seen in the picture 4 Place the bundle the pipe assembly cable and drain hose in the lower part of the indoor unit carefully so it doesn t Unit mm 022 028 036 project from the rear of the indoor unit 5 Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place 6 Wrap the rest of the pipe with vinyl tape 36 appendix 7 Attach the pipe to the wall using clamps
30. l Grab the side of the front panel tightly and push it downward Clean the Anti allergy filter every 3 months The cleaning term may differ on usage and environmental conditions 30_ cleaning and maintaining REPLACING THE FILTER Replacement filter may be purchased from the retail store or ordered from the dealer where you purchased the unit If you cannot find one please call a contact center Deodorizing filter Deodorizing filter absorbs efficiently cigarette smoke pet odors and other unpleasant smells Deodorizing filter cleaning is simple just remove old filter and install a new one 1 Open the front panel Tightly grab the grooved surface on both side of the front panel and lift the bottom side of the panel up until it gets locked HSITSNA 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the Deodorizing filter color in black out to remove it from the slot NO BI MA 7777777717111 TA Ka IG ies Caan OP EE ee LE LL PP ELLE LLL EL Lt 4 HI I HA HI HA HI sa Ala O a c c s E l CE il MM Mm NTT f JI Lal E
31. l to decrease or increase the desired temperature Set Temp Auto You can set the desired temperature between the range of 18 C 30C You can decrease increase the temperature by 1 C a 4 e When the air conditioner is already operating in another mode press the Mode button until Auto mode indicator appears on the remote control display e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions 14_ operating Cool In Cool mode the air conditioner will cool your room You can adjust the temperature and the fan speed to feel cooler in hot season 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Cool mode indicator appears on the remote control display The air conditioner operates in Cool mode and it will lower the temperature in your room Set Temp Cool Fa Auto E H HSINONI Mode Fan Speed l K When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temperature V or A button on the remote ATO control to decrease or increase the desired temperature E You can set the desired temperature between Na auto IL LT the range of 16C 30 C You can decrease inc
32. ly or disabled people The packaging material and used batteries of the remote controller optional must be disposed of in accordance with the national standards The refrigerant used in the air conditioner must be treated as chemical waste Dispose the refrigerant following national standards Have a qualified service technician install the air conditioner and perform a trial operation Firmly connect the drain hose to the air conditioner for proper water drainage Check for damages on the outdoor unit installation pad at least once a year e Potential risk of personal injury or property loss When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If the remote control is not used for a long period of time remove the batteries to prevent leakage of electrolyte When cleaning the outdoor unit touch the heat exchanger radiator fins with extreme care e Wearing thick gloves can protect your hands Make sure that the condensed water dripping from the drain hose runs out properly and safely The appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Young children should be supervised to ensure that they do not play with the appliance safety
33. nce write the model and serial number Model down You will find your model number on the bottom of the Serat air conditioner ena 02 features safety information To prevent electric shock disconnect the power before servicing cleaning and installing the air conditioner SAFETY INFORMATION Before using your new air conditioner please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance Because the following operating instructions cover various models the characteristics of your air conditioner may differ slightly from those described in this manual If you have any questions call your nearest contact center or find help and information online at www samsung com HSITON3 Important safety symbols and precautions Hazards or unsafe practices that may result in severe personal injury or WARNING death Hazards or unsafe practices that may result in minor personal injury or CAUTION Property damage To reduce the risk of fire explosion electric shock or personal injury when CAUTION using your air conditioner follow these basic safety precautions Do NOT attempt Do NOT disassemble Do NOT touch Follow directions carefully Unplug the power plug from the wall socket Make sure the machine is grounded to prevent electric shock Call the contact center for help NE ELI Note
34. nder water 0 0 A Sem I less Do NOT bend the hose in different directions Keep a clearance of at least 5cm between the end of the hose and the ground Do NOT place the end of the drain hose in a hollow appendix 37 HSITON3 Drain hose installation 1 If necessary connect the 2 meter extension drain hose to the drain hose Shield Na Z ULL Era ii TOE Drain hose Extension drain hose 2 If you use the extension drain hose insulate the inside of the extension drain hose with a shield 3 Fit the drain hose into 1 of 2 drain hose holes then fix the end of the drain hose tightly with a clamp Ifyou don t use the other drain hose hole block it with a rubber stopper 4 Pass the drain hose under the refrigerant pipe keeping the drain hose tight 5 Pass the drain hose through the hole in the wall Check if it slants downwards as seen in the picture sx The hose will be fixed permanently into position after finishing the installation and the gas leak test Changing Direction of the Drain Hose You can select the direction of the drain hose depending on where you want to install the indoor unit 1 Detach the rubber cap with the flyer 2 Detach the drain hose by pulling it and turning to the left 3 Insert the drain hose by fixing it into the groove of the drain hose and the outlet of the drain pan 4 Attach the rubber cap with a s
35. nstall and set the address according to the plan You may not need to set MAIN address if you selected Auto Address Setting from the outdoor unit see details on the outdoor unit installation manual For Sample When MAIN address is set as 12 Setting RMC Address The 5W03 SW04 RMC switch is the address setting switch for controlling the indoor unit with the centralized controller You must set the SW03 SW04 and K2 switch when using the centralized controller For Sample When RMC address is set as 12 Additional Functions KI K2 K3 K4 See ON i SW05 External room sensor Not use 3k K1 OFF Heating mode Setting temperature compensation value 0 C Thermo OFF Fan OFF K5 K6 K7 K8 SA KI K10 K11 K12 fi ON NOD 1234 SW07 Indoor Expansion Valve o For Heating Stop Fix 80 step 0 or 80 step External Control Output Thermal ON Operation ON K9 Wired Remocon Group 12 appendix _39 nora ue Centralized controller HSITON3 QUESTIONS OR COMMENTS COUNTRY CALL OR VISIT US ONLINE AT COUNTRY CALL OR VISIT US ONLINE AT AUSTRIA 0810 SAMSUNG 7267864 0 07 min www samsung com UKRAINE 0 800 502 000 www samsung com ua Ukrainian be Dutch www samsung com ua ru Russian www samsung com be Dutc BELGIUM 02 201 24 18 Dr www samsung com be fr French MOLDOVA 0 800 614 40 www samsung com BOSNIA 051 133 1999 www samsung com UAE 800 SAMSUNG 7
36. ntaining _29 cleaning and maintaining tne alr conaltioner CLEANING THE FILTER Anti allergy filter Washable foam based Anti allergy filter leads to reduction in allergens that thrive in polluted air The filter is cleaned with a vacuum or by hand washing 1 Open the front panel Tightly grab the grooved surface on both side of the front panel and lift the bottom side of the panel up until it gets locked 2 Remove the Air filter Grab the handle and lift it up Then pull the Air filter towards you and slide it down 3 Slide the Anti allergy filter color in sky blue out to remove it from the slot TOTTI ALL BAAGAAUKANAAANA NANANA saa NT G PIA Mega aa OT z Meee nn rf HU HI Lal a fl m YO BT YF TD UA e Anti allergy filter can be placed in any 4 slots beneath the air filter e Front panel of your air conditioner is actually not detachable 4 Clean the Anti allergy filter with a vacuum cleaner or soft brush Then rinse it with running water and dry it in a ventilated area 5 Install the Anti allergy filter back in position 6 Close the front pane
37. on is available in Auto Cool Dry Fan Heat mode KK e Temperature can also be adjusted See step 3 on page 15 for instructions e After the set up while the unit is off approximately after 10 seconds all the other indicators will be gone except the On timer indicator and remaining time e Setting time allows you to change by pressing the On button Press the Up or Down button to change time setting and then press the Set Cancel button to active it on To deactivate the On timer 1 Press the Set Cancel button on the remote control On timer you set will be canceled and On timer indicator will disappear using advanced functions 21 using advanced functions SETTING TIMER Off timer This function allows you to turn off the air conditioner automatically within the time range of 24 hours Off timer is functional when the unit is operating 1 Press the Off button on the remote control Off timer indicator blinks on the remote control display mg Set Temp JAuto 2 Set the time you want the air conditioner to turn off automatically Set Temp Auto Press the Up or Down button on the remote control to change the time setting while Off timer indicator is blinking You can set the time up to 24 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours or good Up Set Cancel Sleep o 31 or Fi 3 Press the Set Cancel button on the remote
38. optional Installation plate C7 TZ L LL LA 8 Select the insulation of the refrigerant pipe Insulate the gas side and liquid side pipe referring to the thickness according to the pipe size The thickness according to the pipe size is a standard of the indoor temperature of 27 C and humidity of 80 If installing in an unfavorable conditions use thicker one Insulator s heat resistance temperature should be more than 120 C Minimum thickness of insulation mm Pipe size mm Remarks EPDM PE foam foam If you install the pipe 6 35 01588 13 10 underground at the seaside a spa or on the lake use 1 grade pf thicker one according to the pipe size CAUTION Install the insulation not to get wider and use the adhesives on the connection part of it to prevent moisture from entering Wind the refrigerant pipe with insulation tape if it is exposed to outside sunlight Install the refrigerant pipe respecting that the insulation does not get thinner on the bent part or hanger of pipe Add the additional insulation if the insulation plate gets thinner Installing and Connecting the Drain Hose of the Indoor Unit When installing the drain hose for the indoor unit check if condensation draining is adequate When passing the drain hose through the 65mm hole drilled in the wall check the following The hose must NOT slant The end of the drain hose upwards must NOT be placed u
39. or which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions operating 17 HSITONA operating basic function SELECTING OPERATION MODE Heat The air conditioner heats as well as cools Warm your room with this versatile appliance in the cold of winter 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Set Temp Heat mode indicator appears on the remote control sy cai display The air conditioner operates in Heat mode and warms your room Z When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the temperature Press the Temperature V or A button on the remote Set Temp control to decrease or increase the desired temperature IC You can set the desired temperature between L Uc the range of 16 C 30 C You can decrease increase the temperature by 1 C 4 Set the fan speed Press the Fan Speed button on the remote control to set the desired fan speed If room temperature reaches desired value heating will stop for a while co e When you press the Fan Speed button fan speed will change in order of Auto Low Medium and High Fan Speed e Fan may not operate for about 3 5 minutes at the beginning to prevent any cold blasts while the air
40. otential risk of malfunction electric shock or fire If repairs are needed consult the contact center Consult the place of purchase or contact center to install reinstall or disassemble the air conditioner e Improper installation carries a risk of unit malfunction water leakage electric shock or fire e f installing in specialty areas such as a factory complex or saline coastal area consult the place of purchase or contact center for specific installation details e The units must be installed according to distances declared in order to permit accessibility from each side either to guarantee correct operation of maintenance or repairing products The unit s parts must be reachable and removable completely under safety condition for people or things HSITSNA Consult a dealer regarding the appropriate measures to prevent the allowable concentration from being exceeded e f the refrigerant leaks and cause the concentration limit to be exceeded hazards due to lack of oxygen in the room may result If the indoor unit gets wet turn the power off immediately and call your nearest contact center e Potential risk of fire or electric shock Always make sure that the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Verify that the voltage and frequency of the power supply comply with the specifications and that the installed po
41. pecial tools are needed to clean it Air filter Washable foam based air filter captures large particles from the air The filter is cleaned with a vacuum or by hand washing 1 Open the front panel Tightly grab the grooved surface on both side of the front panel and lift the bottom side of the panel up until it gets locked 2 Grab the handle and lift it uo Then pull the Air filter towards you and slide it down iY Front panel of your air conditioner is actually not detachable 3 Clean the Air filter with a vacuum cleaner or soft brush If dust is too heavy then rinse it with running water and dry it in a ventilated area iY e For the best conditions repeat every two weeks e f the Air filter dries in a confined or humid area odors may generate If it occurs re clean and dry it in a well ventilated area 4 Insert the Air filter back in its original position 5 Close the front panel Grab the side of the front panel tightly and push it downward cleaning and mai
42. perating mode Press the Mode button on the remote control until Cool Heat appears on the remote control display good sleep is only available in Cool Heat mode 2 Press the good sleep button on the remote control good sleep indicator appears and Off timer indicator starts blinking on the remote control display Set Temp Timer good Up Set Cancel Sleep 3 Set the length of time you want the air conditioner to stay on Set Temp Default good sleep time is set to 8 hours Press the J1 Up or Down button on the remote control to change the L Tc time setting while Off timer indicator is blinking Al You can set the time up to 12 hours increasing in 30 minute unit up to first 3 hours and in hourly unit after first 3 hours Timer good Up Set Cancel sleep 4 Press the Set Cancel button on the remote control to active it on The remote control display will show the hour s you have set When the set time has elapsed the air conditioner will automatically turn off and then good sleep indicator disappears If good sleep mode is not set within 10 seconds the air conditioner will end setting 69 e Temperature Fan speed Air swing can be adjusted after setting good sleep in Heat mode e Temperature can be adjusted and the air conditioner automatically adjusts the Fan speed Air swing after setting good sleep in Cool mode 24 using advanced fun
43. r details of where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal contents 09 viewing your alr conaitloner Congratulations on the purchase of the air conditioner We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency Please read the user manual to get started and to make the best use of the air conditioner CHECKING THE INDOOR UNIT AND DIGITAL DISPLAY Carefully unpack your air conditioner and check the unit to make sure it is not damaged Main parts Air intake Air filter under the panel L PJ n zz ia zzz Digital display dig Magaang b 2 N emesis Pra NY z7 Power button TAP a sinabi paaa ta wo Na l4 Your air conditioner may slightly look different from illustration shown above depending on your model Indoor unit digital display mpizone indicator Timer good sleep EDI l BA Evaporator clean CLEAN indicator indicator Temperature indicator Operation indicator 10_ viewing OPENING THE FRONT PANEL Tightly grab the grooved surface on both side of the front panel and lift the bottom side of the panel up until it gets locked in one position
44. rease the temperature by 1 C 4 Set the fan speed Cool Press the Fan Speed button on the remote control to set the desired fan speed High If room temperature reaches desired value the air conditioner will shut off cooling for a while and just the fan runs Fan Speed Fan Speed IZ When you press the Fan Speed button fan speed will change in order of Auto Low Medium and High iY e When you are using the remote control make sure correct indicator which matches your selection appears on the remote control display e Air flow can be adjusted manually See page 19 for instructions e f current outside temperatures are much higher than the selected indoor temperature it may take time to bring the inner temperature to the desired coolness operating 15 operating basic function SELECTING OPERATION MODE Dry The air conditioner in Dry mode acts like a dehumidifier by removing moisture from the indoor air Dry mode makes the air feel refreshing in a humid climate 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Dry mode indicator appears on the remote control display Set Temp The air conditioner operates in Dry mode and automatically adjusts the fan speed to Auto iY When you press the Mode button mode will change in order of Auto Cool Dry Fan and
45. samsuna com SINGAPORE 1800 SAMSUNG 726 7864 www samsung com sg SAMSUNG ELECTRONICS CO LTD No 501 Suhong East Road Suzhou Industrial Park Jiangsu Province P R China AEEE Yonetmeligine Uygundur This product is ROHS compliant Samsung Electronics UK Ltd Euro QA Lab Blackbushe Business Park Saxony Way Yateley Hampshire GU46 6GG United Kingdom Wall Mounted Type Series Vivace AVXWV NH VH X 100 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product DB98 31 7434 09
46. ssing the button on the remote control you will hear beep sound from the unit K e The signal may not be received well of electronic lighting style fluorescent lamps such as inverter fluorescent lamps are in the same space e f other electrical products operate by the remote control call your nearest contact center Installing the batteries gt gt 1 Slide the cover on the 2 Install two AAA batteries 3 Close the cover by sliding rear side of the remote Check and match the it back to its original control down to open and signs accordingly position Make sure you have installed You should hear click sound the batteries in correct when the cover is locked position properly Correct disposal of batteries in this product Applicable in the European Union and other European countries with separate battery return systems This marking on the battery manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in EC Directive 2006 66 If batteries are not properly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them
47. t Thoroughly clean the heat exchanger 2 Ce Clean the condensate drain pipe 2 Replace the remote control batteries 1 Clean the heat exchanger on the outside of pa the unit 2 Clean the heat exchanger on the inside of pa the unit 2 Clean the electric components with jets of pa air 2 Coico oral Verify that all the electric components are pa firmly tightened 2 Clean the fan 2 Verify that all the fan assembly is firmly pa tightened Clean the condensate drain pan 2 Z The checks and maintenance operations described are essential to guarantee the efficiency of the air conditioner The frequency of these operations varies according to the characteristics of the area the amount of dust etc 1 The described operations should be performed more frequently if the area of installation is very dusty 2 These operations must always be performed by qualified personnel For more detailed information see the Installation Manual 32_ cleaning and maintaining Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner Type Description The internal fan will be off to against cold air when the heat pump is Against cold air heating The internal fan will be off to against cold air when the heat pump is De ice cycle heating m G C Anti protection of The compressor will be off to protect internal battery when t
48. the set temperature is higher lower than the current temperature Press the Temperature V or A button on the remote control to change the set temperature Press the Temperature V or A button to decrease or increase the temperature e Check if the air filter is blocked by dirt Clean the Air filter every two weeks e Check if the air conditioner has just been turned on If so wait 3 minutes The fan speed does not change e Check if you selected Auto or Dry mode The air conditioner automatically adjusts the fan soeed to Auto in Auto Dry mode Timer function does not set Check if you press the Set Cancel button on the remote control after you have set the time Odors permeate in the room during operation Check if the appliance is running in a smoky area or if there is a smell entering from outside Operate the air conditioner in Fan mode or open the windows to air out the room The air conditioner makes a bubbling sound Water is dripping from the air flow blades A bubbling sound may be heard when the refrigerant is circulating through the compressor Let the air conditioner operate in a selected mode Check if the air conditioner has been cooling for an extended period of time with the air flow blades pointed downwards Condensation may generate due to the difference in temperature Remote control is not working Check if your batteries are depleted e Make sure batteries are correctly installe
49. through your local free battery return system viewing _13 operating basic function TURNING THE AIR CONDITIONER ON AND OFF Press the Power button on the remote control You will hear a ringing sound and the air flow blade will move up and down automatically when the air conditioner is properly on oS The air conditioner will operate in the most recent operation mode used or Auto mode When you turn off the air conditioner air flow blade will stop moving and remain closed Turning on off your air conditioner without the remote control You can operate your air conditioner by pressing the Power lt button on the right bottom side of the air conditioner SELECTING OPERATION MODE Auto In Auto mode the air conditioner will automatically set the temperature and fan speed depending on the room temperature detected by the room temperature sensor 1 Turn on the air conditioner Press the Power button on the remote control 2 Set the operating mode Press the Mode button on the remote control until Auto SetTemp Auto mode and Auto fan speed indicator appear on the remote NI control display L tc The air conditioner will automatically set the operation mode to Cool or Heat depends on the room temperature IZ When you press the Mode button mode will change in order of Auto Cool Dry Fan and Heat 3 Set the Temperature Press the Temperature V or A button on the remote contro
50. wer is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines Use a rated circuit breaker only e Never use steel wires or copper wires as a circuit breaker It may cause fire or unit malfunctions Do not put undue stress or place heavy object on the power cable Do not bend the power cable excessively e Potential risk of fire or electric shock To protect the product from water and possible shock you should keep the power cable and the connection cord of the indoor and outdoor units in the protection tube When opening or closing the front panel use a stable stool and watch your steps carefully Disconnect the air conditioner from power supply before it is repaired or disassembled Clean the air conditioner after the inner fan stops operating e Potential risk of injury or electric shock safety information _05 satety information 44 SEVERE WARNING SIGNS CONT D WARNING Use a receptacle that has a ground terminal The receptacle must be used exclusively for the air conditioner e Improper electrical grounding may cause electric shock or fire Be sure to ground the unit Do not connect the ground wire to gas or water pipes lighting rods or telephone grounding lines e f the unit is not properly grounded electric shock may result If you smell burning plastic hear strange sounds or see smoke coming from the unit unplug the air conditioner
51. zene thinner or alcohol to clean the surface of the unit e Potential risk of electric shock or fire e Potential risk of damage to the air conditioner Do not place any objects especially containers with liquid 06 safety information Do not touch the pipe connected to the air conditioner Install the indoor unit away from lighting apparatus using the ballast e f you use the wireless remote control reception error may occur due to the ballast of the lighting apparatus Install the outdoor unit where operating noise and vibration will not disturb your neighbor and in a well ventilated area with no obstacle e Potential risk of malfunction e Operating noise may disturb your neighbor Make sure that there are no obstacles or covers that block the air conditioner Allow sufficient space for air circulation e Insufficient ventilation may result in poor performance HSITON3 If the power cable is damaged the manufacturer or a qualified service technician must replace it If a power outage occurs while the air conditioner is working turn off the power source immediately Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency Check for damage on delivery If damaged do not install the air conditioner and call the place of purchase immediately Keep indoor temperatures stable and not extremely cold especially where there are children elder